Klixon and 285 Series Mounting Options Klixon Circuit Breakers
Transcription
Klixon and 285 Series Mounting Options Klixon Circuit Breakers
CIRCUIT PROTECTION AND SWITCHES 67 bluesea.com Fuse Block Specification Table MAXI® ST-Glass 56 / 5006100 56 / 5015, 5018 57 / 5023 58 / 5035, 5037 59 / 5032 60 / 5045, 5046 61 / 5028, 5025, 5029, 5026 For use with MAXI® AGC® or MDL® ATO® or ATC® ATO® or ATC® ATO® or ATC® ATO® or ATC® ATO® or ATC® Maximum Voltage Product Page number / PN ST-Blade 32V DC 32V DC 32V DC 32V DC 32V DC 32V DC 32V DC Maximum Amperage per circuit 80A 30A 30A 30A 30A 30A 30A Maximum Amperage per block 80A 100A 100A 40A per jumped circuit group 100A (not to exceed 80A per load group) 100A 100A 30–80A .25–30A 1–30A 1–30A 1–30A 1–30A 30–300A Available Fuses Ingress Protected IP66-protected against powerful water jets. –– IP66-protected against powerful water jets. –– –– IP66-protected against powerful water jets. –– Ignition Protected ISO 8846, SAE J1171 when cover is secure. –– ISO 8846, SAE J1171 when cover is secure. –– –– ISO 8846, SAE J1171 when cover is secure. –– MEGA® or AMG® Class T Class T Class T 63 / 5502100 Product MRBF Terminal MRBF Surface MRBF Surface Page number / PN 62 / 2151, 5191 62 / 5194 62 / 5196 62 / 5001 63 / 5502 63 / 5007100 For use with Terminal (MRBF) Terminal (MRBF) Terminal (MRBF) MEGA® or AMG® Class T Class T Class T 32V DC 160V DC 160V DC 160V DC Maximum Voltage 58V DC 58V DC Maximum Amperage per circuit 300A 240A 240A 300A 320A 160A 320A Maximum Amperage per block 300A –– 300A 300A 320A 160A 320A 30–300A 30–300A 30–300A 100–300A 225–400A 110–200A 225–400A –– –– –– –– –– –– Available Fuses Ingress Protected IP66 when used with Blue Sea Systems' Terminal (MRBF) Fuses. Ignition Protected SAE J1171 when used with Blue Sea Systems' MRBF fuses. Product Page number / PN For use with Maximum Voltage –– ANL® ANL® 63 / 5005 63 / 5503 ANL® ANL® Safety AMI® or MIDI® ISO 8846, SAE J1171 when cover is secure. ISO 8846, SAE J1171 when cover is secure. Safety MEGA® or AMG® SafetyHub 100 SafetyHub 150 64 / 7720 64 / 7721 65 / 7725 65 / 7748 AMI® or MIDI® MEGA® or AMG® AMI® or MIDI® and ATO® or ATC® 32V DC 32V DC 32V DC 32V DC 12V DC 32V DC Maximum Amperage per circuit 300A 750A 200A 300A AMI® or MIDI®: 250A ATO® or ATC®: 30A AMI® or MIDI®: 170A ATO® or ATC®: 25A Maximum Amperage per block 300A 750A 200A 300A ATO® or ATC®: 50A AMI® or MIDI®: 280A ATO® or ATC®: 50A Maximum Total Amperage (combined) 35–300A –– –– –– 280A AMI® or MIDI®: 30–200A ATO® or ATC®: 1–30A AMI® or MIDI®: 30–200A ATO® or ATC®: 1–30A Available Fuses –– 35–750A Ingress Protected –– –– IP66-protected against powerful water jets. IP66-protected against powerful water jets. Ignition Protected –– –– ISO 8846, SAE J1171 when cover is secure. ISO 8846, SAE J1171 when cover is secure. 30–200A 100–300A