Filotex® Standard hook-up wires and cables for electronics Low current high technology wires and cables: expertise in the service of industry The Filotex® products presented in this catalogue have been designed and manufactured in our French facilities at Draveil, Paillart and Fumay. A leader worldwide as well as in Europe and France, Alcatel Cable is pleased to enable its customers to benefit from its leading-edge expertise across a broad line of high technology sectors. Whether in the Aeronautics, Space, Rail, Professional Electronics, Defense, Medical Imaging or Automotive industries, Alcatel Cable is present internationally and offers a complete range of products and solutions. Miniaturization, electromagnetic protection, the safety and security of goods and persons, resistance to high temperatures, weight savings: in responding to each of these challenges, our company has earned a reputation for innovation and performance. In addition to the standard products you will find within these pages, our development and studies engineers are at your disposal to provide their experience in tailoring any of our products to meet your precise requirements. 2 Parameters of selection of a cable ● Specification or Standard to comply with ● Operating temperature ● Operating voltage ● Number of cores and dimensions ● Need for screen ● Design of each element (core, insulation, dimensions, colour coding, marking, nature of screen, nature of outer jacket,...) ● Environment ● Specific performances (ex : cylindricity, flexibility, radial or longitudinal waterproof,...) ● Spooling and packaging (ex : reels, drums, wished lengths per reel,...) ● Length of using ● Application 3 Properties of various insulation materials INSULATION MATERIALS PROPERTIES (AVERAGE) P.E. POLYETHYLENE LOW DENSITY ELECTRICAL PROPERTIES Dielectric cnnstant at 103Hz 2,25 up to 2,35 PVC 3,50 FLEXIBLE PVC 4,50 ETFE 2,6 PHYSICAL PROPERTIES Density 0,910 up to 0,925 1,27/1,37 1,27/1,37 1,7 Low temperature -90°C -40°C -20°C up to-65°C -100°C High temperature +75°C +85°C up to +110°C +75°C +150°C Flexibility 1 2 3 1 Abrasion 1 2 2 2 resistance Soldering 1 2 2 2 resistance CHEMICAL PROPERTIES Withstanding: Weak acids Weak bases Strong acids Strong bases Organic solvents 3 3 0 3 attacked at ≥ 60° C PTFE FEP FLAMEX POLYIMIDE (KAPTON ®) 2,0 2,6 up to 2,7 3,50 (TEFZEL®) (TEFLON®) 2,0 2,16 2,16 1,3 1,54 up to1,91 -90°C -90°C -20 up to -50°C -90°C +260°C +200°C 105 up to150°C +200°C 1 1 2 up to 3 1 1 1 2 up to 3 3 3 3 2 up to 3 3 3 3 3 3 3 3 1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 2 3 1 * * 3 3 3 3 3 Understanding : 0 1 2 3 * Not recommanded Medium or weak Good Excellent Withstands alcohol, oil and aliphatic hydrocarbons fluids. Attacked by cetones, esters and aromatic hydrocarbons fluids ® TEFZEL, KAPTON and TEFLON are DU PONT de NEMOURS registred trade marks. 4 Guideline based on operating temperature HOOK-UP WIRES AND MULTICORE CABLES - DATA SHEETS OPERATING TEMPERATURE 80°C HOOK-UP WIRES MULTICORE CABLES HT FM / FMA FM / FMA EHE / EHEA EHE / EHEA SMA / SMBL GRTH / CCTB 105°C 125°C 150°C 200°C and + KY / EPDX KY / EPDX 1604 / 604 604 FLAMEX 10 FLAMEX 15 FLAMEX 15 FLAMEX 24 FLAMEX 24 1806 / 806 806 KU KU M22759 / 16 - M22759 / 18 KZ04 / KZ05 / KZ06 KZ55 / KZ57 / KZ59 KZ67 / KZ69 / KZ71 KZ79 / KZ81 / KZ83 ETF / EF / EEF EXTRA-FLEXIBLE WIRES AND CABLES - WRAPPING WIRES - DATA SHEETS - 75°C 80°C 90°C from 85°C up to 200°C and + SM DFSG FTM FT/FR WCP / KW01C1 WCY / KW02C1 WCZ / KW02B1 WCT / KW03A2 5 Hook-up wires PERFORMANCES OPERATING TEMPERATURE 80°C CONSTRUCTION OPERATING VOLTAGE CONDUCTOR INSULATION BRAID AWG OUTER JACKET 250 V 24 PVC Stranded Tinned copper PVC conductor 24 High PE conductive PVC sheath 750 V PVC Tinned copper PE High conductive sheath 105°C V V V V 22 PVC 22 22 20 Stranded tinned copper 24 22 Tinned copper 000 000 000 000 24 22 PVC Stranded tinned copper 4 5 7 12 24 24 tinned copper conductor 24 20 PE/PVC 16 conductor 16 30 250 V 28 26 24 Stranded tinned copper PVC conductor Tinned copper 22 «P» = POLYAMIDE 20 18 16 14 12 10 24 600 V 22 20 Stranded tinned copper conductor PVC/PA Tinned Uncoloured copper superpolyamide 18 16 14 12 10 (continued .../...) 6 8 REFERENCES NF UNSCREENED SCREENED SCREENED AND JACKETED DESIGNATION DESIGNATION DESIGNATION MIL FILOTEX NF MIL FILOTEX NF MIL FILOTEX FM1R FMA1R FM1M FMA1M EHE1PR EHEA1PR EHEA1PM FM1 FMA1 EHEA1P FM1P FMA1P HT306E HT406E HT610E HT810E KY30-01 EPDX 6x0 KY30-02 EPDX 5x0 KY30-03 EPDX 4x0 KY45-01 EPDX 4x0BL KY46-01 EPDX4x0 BLP KY30-04 EPDX 000 KY45-02 EPDX 000BL KY46-02 EPDX3x0 BLP KY30-05 EPDX 00 KY45-03 EPDX 00BL KY46-03 EPDX00 BLP KY30-06 EPDX 26 KY30-07 EPDX 27 KY30-08 EPDX 28 EPDX 29 EPDX 100 EPDX 140 1604 0,21 604 1x0,21 1604 0,38 604 1x0,38 1604 0,60 604 1x0,60 1604 0,93 604 1x0,93 1604 1,34 604 1x1,34 1604 1,91 604 1x1,91 1604 3,18 1604 5,15 1604 8,98 7 Hook-up wires PERFORMANCES OPERATING TEMPERATURE 105°C CONSTRUCTION OPERATING VOLTAGE CONDUCTOR INSULATION BRAID AWG OUTER JACKET 750 V 24 24 22 22 20 20 18 Stranded tinned copper PVC conductor Tinned «P» = POLYAMIDE copper «I» = PVC 18 16 16 14 14 12 10 9 8 4 22 Solid tinned copper 20 PVC 18 conductor 14 12 20 18 Stranded FLAMEX 16 tinned copper (Halogen 14 conductor free) 14 12 10 125°C 8 750 V 24 Stranded FLAMEX tinned copper (Halogen conductor free) Tinned copper FLAMEX (T° 105°C) 22 20 REFERENCES UNSCREENED SCREENED DESIGNATION DESIGNATION NF KY33A01 KY33A02 KY33A03 KY33A04 KY33A05 KY33A06 KY33A07 KY33A08 MIL FILOTEX EPDX 6 EPDX 7 EPDX 16 EPDX 17 EPDX 8 EPDX 9 NF KY37A01 KY37A02 KY37A03 KY37A04 KY37A05 KY37A06 MIL SCREENED AND JACKETED FILOTEX EPDX 6 BL EPDX 7 BL EPDX 16 BL EPDX 17 BL EPDX 8 BL EPDX 9 BL DESIGNATION NF MIL FILOTEX KY41A01 EPDX 6 BLI KY44A01 EPDX 6 BLP KY41A02 EPDX 7 BLI KY44A02 EPDX 7 BLP KY41A03 EPDX 16 BLI KY44A03 EPDX 16 BLP KY41A04 EPDX 17 BLI KY44A04 EPDX 17 BLP KY41A05 EPDX 8 BLI KY44A05 EPDX 8 BLP KY41A06 EPDX 9 BLI KY44A06 EPDX 9 BLP EPDX 10 EPDX 14 EPDX 18 KY33A09 EPDX 15 KY33A10 EPDX 19 KY31A01 EPDX 1 KY31A02 EPDX 2 KY31A03 EPDX 3 KY31A04 EPDX 4 KY31A05 EPDX 5 Flamex 10 0,60 Flamex 10 0,93 Flamex 10 1,34 Flamex 10 1,82 Flamex 10 2,61 Flamex 10 4,32 Flamex 10 6,00 Flamex 15 0,25 Flamex 15 0,38 Flamex 15 0,38 BLG Flamex 15 0,60 Flamex 15 0,60 BLG 9 Hook-up wires PERFORMANCES OPERATING TEMPERATURE 150°C CONSTRUCTION OPERATING VOLTAGE CONDUCTOR INSULATION BRAID AWG OUTER JACKET 600 V 24 22 Stranded tinned copper FEP/PA conductor Cuivre Étamé Uncoloured 20 superpolyamide 18 (T° 140°C) 16 14 12 750 V 20 Stranded FLAMEX tinned copper (Halogen conductor free) 18 Tinned FLAMEX 16 copper (T° 105°C) 14 12 12 30 28 26 24 ETFE Tinned copper ETFE 22 20 18 16 14 12 24 22 20 18 Stranded tinned copper conductor Lightweight series 16 14 12 10 8 6 4 2 26 24 Extralightweight series 22 20 18 16 14 12 10 10 REFERENCES NF UNSCREENED SCREENED DESIGNATION DESIGNATION MIL FILOTEX NF MIL SCREENED AND JACKETED FILOTEX DESIGNATION NF MIL FILOTEX 1806 0,21 806 1x0,21 1806 0,38 806 1x0,38 1806 0,60 806 1x0,60 1806 0,93 806 1x0,93 1806 1,34 806 1x1,34 1806 1,91 806 1x1,91 1806 3,18 806 1x3,18 Flamex 24 0,60 Flamex 24 0,93 Flamex 24 0,93 BLG Flamex 24 1,34 Flamex 24 1,34 BLG Flamex 24 1,82 Flamex 24 2,61 Flamex 24 4,32 KU01-30 KU01-30 KU02-30 KU02-30 KU01-28 KU01-28 KU02-28 KU02-28 KU01-26 KU01-26 KU02-26 KU02-26 KU01-24 KU01-24 KU02-24 KU02-24 KU01-22 KU01-22 KU02-22 KU02-22 KU01-20 KU01-20 KU02-20 KU02-20 KU01-18 KU01-18 KU02-18 KU02-18 KU01-16 KU01-16 KU02-16 KU02-16 KU01-14 KU01-14 KU02-14 KU02-14 KU01-12 KU01-12 KU02-12 KU02-12 M22759/16-24 M22759/16-22 M22759/16-20 M22759/16-18 M22759/16-16 M22759/16-14 M22759/16-12 M22759/16-10 M22759/16-8 M22759/16-6 M22759/16-4 M22759/16-2 M22759/18-26 M22759/18-24 M22759/18-22 M22759/18-20 M22759/18-18 M22759/18-16 M22759/18-14 M22759/18-12 M22759/18-10 11 Hook-up wires PERFORMANCES OPERATING TEMPERATURE 200°C and + CONSTRUCTION OPERATING VOLTAGE CONDUCT0R INSULATION BRAID AWG OUTER JACKET 250 V 32 30 30 28 Polyimide silvered copper 28 tape Stranded PTFE conductor + silvered 26 FEP 26 24 copper 24 braid 22 22 20 20 600 V 24 22 Stranded silvered copper 20 FEP 18 conductor 16 12 32 30 30 28 28 26 26 24 24 22 Stranded silvered copper conductor PTFE Silvered copper FEP 22 20 20 18 18 16 14 14 12 12 10 (Continued .../...) 12 10 REFERENCES UNSCREENED SCREENED SCREENED AND JACKETED DESIGNATION DESIGNATION DESIGNATION NF MIL FILOTEX KZ04-01 M16878/6-B-A-B ETF-ERT 32-07 KZ55-01 KZ04-02 M16878/6-B-B-B ETF-ERT 30-07 KZ55-02 M16878/6-B-B-E ETF-ERT 30-19 M16878/6-B-C-B ETF-ERT 28-07 M16878/6-B-C-E ETF-ERT 28-19 M16878/6-B-D-B ETF-ERT 26-07 M16878/6-B-D-E ETF-ERT 26-19 M16878/6-B-E-B ETF-ERT 24-07 M16878/6-B-E-E ETF-ERT 24-19 M16878/6-B-F-B ETF-ERT 22-07 M16878/6-B-F-E ETF-ERT 22-19 KZ04-03 KZ04-04 KZ04-05 KZ04-06 KZ04-07 M16878/6-B-G-B ETF-ERT 20-07 M16878/6-B-G-E ETF-ERT 20-19 NF MIL FILOTEX NF MIL FILOTEX ETF-ERT 32-07x1 BLF ETF-ERT 30-07x1 BLF ETF-ERT 30-19x1 BLF KZ55-03 ETF-ERT 28-07x1 BLF ETF-ERT 28-19x1 BLF KZ55-04 ETF-ERT 26-07x1 BLF ETF-ERT 26-19x1 BLF KZ55-05 ETF-ERT 24-07x1 BLF ETF-ERT 24-19x1 BLF KZ55-06 ETF-ERT 22-07x1 BLF ETF-ERT 22-19x1 BLF ETF-ERT 20-07x1 BLF KZ55-07 ETF-ERT 20-19x1 BLF 1850 0,21* 1850 0,38* 1850 0,60* 1850 0,93* 1850 1,34* 1850 3,18* KZ05-01 KZ05-02 M16878/4-B-B-B EF-ER 32-07 KZ57-01 EF-ER 32-07x1 BLF EF-ER 30-07 KZ57-02 EF-ER 30-07x1 BLF EF-ER 30-19 KZ05-03 EF-ER 28-07 EF-ER 30-19x1 BLF KZ57-03 EF-ER 28-19 KZ05-04 M16878/4-B-D-B EF-ER 26-07 KZ57-04 EF-ER 26-19 KZ05-05 M16878/4-B-E-B EF-ER 24-07 M16878/4-B-F-B EF-ER 22-07 KZ57-05 M16878/4-B-G-B KZ57-06 EF-ER 22-07x1 BLF EF-ER 22-19x1 BLF EF-ER 20-07 EF-ER 20-19 EF-ER 24-07x1 BLF EF-ER 24-19x1 BLF EF-ER 22-19 KZ05-07 EF-ER 26-07x1 BLF EF-ER 26-19x1 BLF EF-ER 24-19 KZ05-06 EF-ER 28-07x1 BLF EF-ER 28-19x1 BLF EF-ER 20-07x1 BLF KZ57-07 EF-ER 20-19x1 BLF M16878/4-B-H-B EF-ER 18-07 EF-ER 18-19 KZ57-08 EF-ER 18-19x1 BLF KZ05-09 M16878/21-B-J-E EF-ER 16-19 KZ57-09 EF-ER 16-19x1 BLF KZ05-10 M16878/21-B-K-E ER 14-27 M16878/21-B-L-E ER 12-19 M16878/21-B-M-G ER 10-37 ER 10-37x1 BLF ER 10-73 ER 10-73x1 BLF KZ05-08 EF-ER 18-07x1 BLF ER 14-19 KZ05-11 ER 12-45 ER 14-19x1 BLF KZ57-10 ER 14-27x1 BLF ER 12-19x1 BLF KZ57-11 ER 12-45x1 BLF *Please, contact us 13 Hook-up wires PERFORMANCES OPERATING TEMPERATURE 200°C and + CONSTITUTION OPERATING VOLTAGE CONDUCTOR INSULATION BRAID AWG OUTER JACKET 1000 V 32 30 30 28 28 26 26 24 24 22 Stranded silvered copper conductor PTFE Silvered copper FEP 22 20 20 18 18 16 14 14 12 12 10 10 14 REFERENCES UNSCREENED SCREENED DESIGNATION DESIGNATION NF MIL FILOTEX M16878/6-B-A-B EEF-EER 32-07 KZ59-01 KZ06-02 M16878/6-B-B-B EEF-EER 30-07 KZ59-02 M16878/6-B-B-E EEF-EER 30-19 M16878/6-B-C-B EEF-EER 28-07 M16878/6-B-C-E EEF-EER 28-19 M16878/6-B-D-B EEF-EER 26-07 M16878/6-B-D-E EEF-EER 26-19 M16878/6-B-E-B EEF-EER 24-07 M16878/6-B-E-E EEF-EER 24-19 M16878/6-B-F-B EEF-EER 22-07 M16878/6-B-F-E EEF-EER 22-19 KZ06-04 KZ06-05 KZ06-06 KZ06-07 M16878/6-B-G-B EEF-EER 20-07 M16878/6-B-G-E EEF-EER 20-19 M16878/22-B-H-B EEF-EER 18-07 MIL FILOTEX DESIGNATION KZ06-01 KZ06-03 NF SCREENED AND JACKETED NF MIL FILOTEX EEF-EER 32-07x1 BLF EEF-EER 30-07x1 BLF EEF-EER 30-19x1 BLF KZ59-03 EEF-EER 28-07x1 BLF EEF-EER 28-19x1 BLF KZ59-04 EEF-EER 26-07x1 BLF EEF-EER 26-19x1 BLF KZ59-05 EEF-EER 24-07x1 BLF EEF-EER 24-19x1 BLF KZ59-06 EEF-EER 22-07x1 BLF EEF-EER 22-19x1 BLF EEF-EER 20-07x1 BLF KZ59-07 EEF-EER 20-19x1 BLF EEF-EER 18-07x1 BLF KZ06-08 M16878/22-B-H-E EEF-EER 18-19 KZ59-08 EEF-EER 18-19x1 BLF KZ06-09 M16878/22-B-J-E EEF-EER 16-19 KZ59-09 EEF-EER 16-19x1 BLF M16878/22-B-K-E EER 14-19 KZ06-10 EER 14-19x1 BLF EER 14-27 M16878/22-B-L-E KZ06-11 KZ59-10 EER 12-19x1 BLF EER 12-45 M16878/22-B-M-G EER 14-27x1 BLF EER 12-19 KZ59-11 EER 12-45x1 BLF EER 10-37 EER 10-37x1 BLF EER 10-73 EER 10-73x1 BLF M16878/5-4-6, ETF/EF/EEF = EXTRUDED PTFE INSULATION KZ **-10 and 11, M16878/20-21-22 and ERT/ER/EER = LAPPED PTFE INSULATION Nature of the conductors for KZ hook-up wires and corresponding operating temperature Operating Voltage 250 Volts 600 Volts 1 000 Volts Operating temperature Cu Ag KZ 04 KZ 05 KZ 06 200 °C Cu Ni KZ 07 KZ 08 KZ 09 260 °C Nature of conductors 15 Extra-flexible hook-up wires wrapping hook-up wires Extra-flexible hook-up wires PERFORMANCES OPERATING TEMPERATURE CONSTRUCTION OPERATING VOLTAGE 75°C 48 V 90°C 250 V CONDUCTOR AWG INSULATION 34 Stranded bare copper PVC conductor Solid tinned copper PVC 30 27 29 conductor 31 Stranded tinned copper 28 Flexible PVC conductor 26 24 22 27 Stranded bare copper 22 Flexible PVC conductor 19 16 14 Wrapping hook-up wires 85°C 130°C 150°C 200°C and + 16 350 V 30 Solid tinned copper PVC conductor 350 V 30 PVF2 conductor 28 26 24 30 350 V Solid tinned copper 28 ETFE conductor 350 V 26 24 Solid tinned copper 28 24 30 Solid tinned copper conductor 26 PTFE 28 26 24 REFERENCES UNSCREENED SCREENED SCREENED AND JACKETED DESIGNATION DESIGNATION DESIGNATION NF MIL FILOTEX NF MIL FILOTEX NF MIL FILOTEX SM105 SM245 SM485 SM30 FT5 FT10 FT15 FT30 FT40 FR1 FR3 FR7 FR12 FR19 KW01-30 C1 WCP30 KW01-28 C1 WCP28 KW01-26 C1 WCP26 KW01-24 C1 WCP24 KW02-30 C1 WCY30 KW02-28 C1 WCY28 KW02-26 C1 WCY26 KW02-24 C1 WCY24 KW02-30 B1 WCZ30 KW02-28 B1 WCZ28 KW02-26 B1 WCZ26 KW02-24 B1 WCZ24 KW03-30 A2 WCT30 KW03-28 A2 WCT28 KW03-26 A2 WCT26 KW03-24 A2 WCT24 17 Multicore cables PERFORMANCES OPERATING TEMPERATURE 80°C CONSTRUCTION OPERATING NUMBER VOLTAGE OF CORES 250 V 2 up to 6 500 V 750 V CONDUCTOR INSULATION Stranded PVC tinned copper conductor 2 Stranded up to tinned copper 37 conductor 2 up to 6 PE PVC PVC 2 up to Tinned Copper High conductive Sheath Tinned Copper OUTER JACKET PVC PVC PE Stranded tinned copper 24 & 22 up to 16 Tinned 22 22 22 High conductive 22 Sheath 22 PVC 22 up to PVC 19 24 24 & 22 22 conductor 12 24 24 PVC Copper 2à4 2 up to 3 BRAID AWG Tinned 14 Copper 20 up to 14 105°C 250 V 2 26 Polyamide 24 22 Stranded tinned copper 3 PVC conductor Tinned PVC Copper Polyamide 24 22 26 24 22 PVC 600 V 2 up to Stranded 3 22 24 tinned copper PVC/PA conductor Tinned Copper Superpolyamide 8 24 up to 8 750 V 2 24 Polyamide 22 16 22 Stranded tinned copper 3 conductor PVC Tinned PVC Copper 20 18 16 24 Polyamide 22 16 PVC 18 20 18 REFERENCES LAYED UP AND JACKETED SCREENED SCREENED AND JACKETED DESIGNATION DESIGNATION DESIGNATION NF MIL FILOTEX NF MIL FILOTEX NF MIL FILOTEX FM..R FMA..R EHE..PR/EHE..PM EHEA..PR/EHEA..PM SMA 2X0,22 SMBL 2X0,22 up to up to SMA 37X0,60 SMBL 37X1,34 FM.. FMA.. FM..P/FM..PS FMA..P/FMA..PS EHE..P EHEA..P GRTH 2X0,34 up to CCTB 2x0,60 up to GRTH 12X1,91 CCTB 12x1,91 CCTB 19x0,6 up to CCTB 19x1,91 EPDX 0000X2* KY 93-01 DX 0000 BL KY 91-01 DX 0000 BLP EPDX 000X2* KY 93-02 DX 000 BL KY 91-02 DX 000 BLP EPDX 00X2* KY 93-03 DX 00 BL KY 91-03 DX 00 BLP DKY 30-04 BLBV DKY 30-05 BLBV KY 94-01 TX 0000 BL KY 92-01 TX 0000 BLP KY 94-02 TX 000 BL KY 92-02 TX 000 BLP KY 94-03 TX 00 BL KY 92-03 TX 00 BLP TKY 30-05* TKY 30-05 BLBV 1604 2x0,21* 604 2x0,21 up to up to 1604 2x8,98* 604 2x3,18 1604 3x0,21* 604 3x0,21 up to up to 1604 3x8,98* 604 3x3,18 KY 83A-01 DX6BLP KY 70A-01 DX 7BL KY 83A-02 DX7BLP KY 70A-02 DX 8BL KY 83A-03 DX8BLP DKY 33A-02 BLBV EPDX 16X2* DKY 33A-03 BLBV DKY 33A-04 BLBV DKY 33A-05 BLBV KY 84A-01 KY 72A-01 TX 7 BL TX6 BLP KY 84A-02 TX7 BLP KY 84A-03 TX8 BLP TKY 33A-03BLBV TKY 33A-04BLBV *Cores only layed up 19 Multicore cables PERFORMANCES OPERATING TEMPERATURE 125°C CONSTRUCTION OPERATING VOLTAGE NUMBER OF CORES 750V 2 CONDUCTOR INSULATION BRAID AWG OUTER JACKET 24 22 20 3 Stranded tinned copper conductor FLAMEX Tinned (Sans Halogène) copper FLAMEX 24 (Halogen free) 22 (T° 105° C) 20 4 24 22 20 150°C 600 V 2 24 up to Stranded 3 tinned copper FEP/PA conductor Tinned Superpolyamide copper (T° 140 °C) 14 24 up to 14 2 30 up to Stranded 3 tinned copper ETFE conductor Tinned copper ETFE 12 30 up to 12 750V 2 20 18 16 14 14 12 3 20 Stranded tinned copper conductor FLAMEX Tinned (Halogen free) copper FLAMEX (Halogen free) (T° 105°C) 18 16 14 14 12 4 20 18 16 14 14 12 20 REFERENCES NF LAYED UP SCREENED SCREENED AND JACKETED DESIGNATION DESIGNATION DESIGNATION MIL FILOTEX NF MIL FILOTEX NF MIL FILOTEX Flamex 15 2x0,25 BLG Flamex 15 2x0,38 BLG Flamex 15 2x0,60 BLG Flamex 15 3x0,25 BLG Flamex 15 3x0,38 BLG Flamex 15 3x0,60 BLG Flamex 15 4x0,25 BLG Flamex 15 4x0,38 BLG Flamex 15 4x0,60 BLG 1806 2x0,21 1806 2x0,21 BL up to up to 806 2X0,21 up to 1806 2x1,91 1806 2x1,91 BL 806 2X1,91 1806 3x0,21 1806 3x0,21 BL 806 3x0,21 up to up to up to 1806 3x1,91 1806 3x1,91 BL 806 3x1,91 KU 03-30 KU 03-30 KU 05-30 up to up to up to KU 05-30 up to KU 03-12 KU 03-12 KU 05-12 KU 05-12 KU 04-30 KU 04-30 KU 06-30 KU 06-30 up to up to up to up to KU 04-12 KU 04-12 KU 06-12 KU 06-12 Flamex 24 2x0,60 BLG Flamex 24 2x0,93 BLG Flamex 24 2x1,34 BLG Flamex 24 2x1,82 BLG Flamex 24 2x2,61 BLG Flamex 24 2x4,32 BLG Flamex 24 3x0,60 BLG Flamex 24 3x0,93 BLG Flamex 24 3x1,34 BLG Flamex 24 3x1,82 BLG Flamex 24 3x2,61 BLG Flamex 24 3x4,32 BLG Flamex 24 4x0,60 BLG Flamex 24 4x0,93 BLG Flamex 24 4x1,34 BLG Flamex 24 4x1,82 BLG Flamex 24 4x2,61 BLG Flamex 24 4x4,32 BLG 21 Multicore cables PERFORMANCES OPERATING TEMPERATURE 200°C and + CONSTRUCTION OPERATING VOLTAGE NUMBER OF CORES 250 V 2 CONDUCTOR INSULATION BRAID AWG OUTER JACKET 32 30 30 28 28 26 26 24 24 22 22 Polyimide Stranded 3 silvered copper 20 tape PTFE + Silvered conductor FEP copper 20 32 30 braid 30 28 28 26 26 24 24 22 22 20 20 600 V 32 2 30 30 Stranded silvered copper Silvered PTFE copper conductor FEP 28 28 26 26 (continued .../...) 24 Nature of the conductors for KZ wires and corresponding operating temperature Operating voltage 250 Volts 600 Volts 1 000 Volts operating temperature Cu Ag KZ 04 KZ 05 KZ 06 200 °C Cu Ni KZ 07 KZ 08 KZ 09 260 °C Nature of conductors 22 REFERENCES NF LAYED UP SCREENED DESIGNATION DESIGNATION MIL FILOTEX NF MIL SCREENED AND JACKETED FILOTEX DESIGNATION NF MIL FILOTEX KZ 04-01X2 ETF-ERT 32-07X2 KZ 67-01 ETF-ERT 32-07X2BLF KZ 04-02X2 ETF-ERT 30-07X2 KZ 67-02 ETF-ERT 30-07X2BLF KZ 67-03 ETF-ERT 28-07X2BLF KZ 67-04 ETF-ERT 26-07X2BLF KZ 67-05 ETF-ERT 24-07X2BLF KZ 67-06 ETF-ERT 22-07X2BLF ETF-ERT 30-19X2 KZ 04-03X2 ETF-ERT 28-07X2 KZ 04-04X2 ETF-ERT 26-07X2 KZ 04-05X2 ETF-ERT 24-07X2 KZ 04-06X2 ETF-ERT 22-07X2 ETF-ERT 30-19X2BLF ETF-ERT 28-19X2 ETF-ERT 28-19X2BLF ETF-ERT 26-19X2 ETF-ERT 26-19X2BLF ETF-ERT 24-19X2 ETF-ERT 24-19X2BLF ETF-ERT 22-19X2 ETF-ERT 22-19X2BLF ETF-ERT 20-07X2 ETF-ERT 20-07X2BLF KZ 04-07X2 ETF-ERT 20-19X2 KZ 67-07 ETF-ERT 20-19X2BLF KZ 04-01X3 ETF-ERT 32-07X3 KZ 79-01 ETF-ERT 32-07X3BLF KZ 04-02X3 ETF-ERT 30-07X3 KZ 79-02 ETF-ERT 30-07X3BLF KZ 79-03 ETF-ERT 28-07X3BLF KZ 79-04 ETF-ERT 26-07X3BLF KZ 79-05 ETF-ERT 24-07X3BLF KZ 79-06 ETF-ERT 22-07X3BLF ETF-ERT 30-19X3 KZ 04-03X3 ETF-ERT 28-07X3 KZ 04-04X3 ETF-ERT 26-07X3 KZ 04-05X3 ETF-ERT 24-07X3 KZ 04-06X3 ETF-ERT 22-07X3 ETF-ERT 30-19X3BLF ETF-ERT 28-19X3 ETF-ERT 28-19X3BLF ETF-ERT 26-19X3 ETF-ERT 26-19X3BLF ETF-ERT 24-19X3 ETF-ERT 24-19X3BLF ETF-ERT 22-19X3 ETF-ERT 22-19X3BLF ETF-ERT 20-07X3 ETF-ERT 20-07X3BLF KZ 04-07X3 ETF-ERT 20-19X3 KZ 79-07 ETF-ERT 20-19X3BLF KZ 05-01X2 EF-ER 32-07X2 KZ 69-01 EF-ER 32-07X2BLF KZ 05-02X2 EF-ER 30-07X2 KZ 69-02 EF-ER 30-07X2BLF KZ 69-03 EF-ER 28-07X2BLF KZ 69-04 EF-ER 26-07X2BLF KZ 69-05 EF-ER 24-07X2BLF EF-ER 30-19X2 KZ 05-03X2 EF-ER 28-07X2 EF-ER 30-19X2BLF EF-ER 28-19X2 KZ 05-04X2 EF-ER 26-07X2 KZ 05-05X2 EF-ER 24-07X2 EF-ER 28-19X2BLF EF-ER 26-19X2 EF-ER 26-19X2BLF 23 Multicore cables PERFORMANCES OPERATING TEMPERATURE 200°C and+ CONSTRUCTION OPERATING NUMBER OF VOLTAGE CORES 600 V CONDUCTOR INSULATION BRAID AWG OUTER JACKET 24 2 22 22 20 20 18 Stranded silvered copper PTFE conductor Silvered copper FEP 18 16 14 14 12 12 10 10 3 32 30 30 28 28 26 26 24 24 22 Stranded silvered copper conductor PTFE Silvered copper FEP 22 20 20 18 18 16 14 14 12 12 (continued .../...) 24 10 10 REFERENCES NF LAYED UP SCREENED SCREENED AND JACKETED DESIGNATION DESIGNATION DESIGNATION MIL FILOTEX NF MIL FILOTEX NF EF-ER 24-19X2 KZ 05-06X2 EF-ER 22-07X2 KZ 69-06 EF-ER 22-07X2BLF EF-ER 22-19X2BLF EF-ER 20-07X2 EF-ER 20-19X2 FILOTEX EF-ER 24-19X2BLF EF-ER 22-19X2 KZ 05-07X2 MIL EF-ER 20-07X2BLF KZ 69-07 EF-ER 18-07X2 EF-ER 20-19X2BLF EF-ER 18-07X2BLF KZ 05-08X2 EF-ER 18-19X2 KZ 69-08 EF-ER 18-19X2BLF KZ 05-09X2 EF-ER 16-19X2 KZ 69-09 EF-ER 16-19X2BLF ER 14-19X2 KZ 05-10X2 ER 14-27X2 ER 14-19X2BLF KZ 69-10 ER 12-19X2 KZ 05-11X2 ER 12-45X2 KZ 69-11 ER 10-37X2 KZ 05-02X3 ER 10-73X2BLF EF-ER 32-07X3 KZ 81-01 EF-ER 30-07X3 KZ 81-02 EF-ER 30-19X3 KZ 05-03X3 EF-ER 28-07X3 EF-ER 26-07X3 KZ 81-03 EF-ER 24-07X3 KZ 81-04 EF-ER 22-07X3 KZ 81-05 KZ 81-06 EF-ER 24-07X3BLF EF-ER 22-07X3BLF EF-ER 22-19X3BLF EF-ER 20-07X3 EF-ER 20-19X3 EF-ER 26-07X3BLF EF-ER 24-19X3BLF EF-ER 22-19X3 KZ 05-07X3 EF-ER 28-07X3BLF EF-ER 26-19X3BLF EF-ER 24-19X3 KZ 05-06X3 EF-ER 30-07X3BLF EF-ER 28-19X3BLF EF-ER 26-19X3 KZ 05-05X3 EF-ER 32-07X3BLF EF-ER 30-19X3BLF EF-ER 28-19X3 KZ 05-04X3 ER 12-45X2BLF ER 10-37X2BLF ER 10-73X2 KZ 05-01X3 ER 14-27X2BLF ER 12-19X2BLF EF-ER 20-07X3BLF KZ 81-07 EF-ER 18-07X3 EF-ER 20-19X3BLF EF-ER 18-07X3BLF KZ 05-08X3 EF-ER 18-19X3 KZ 81-08 EF-ER 18-19X3BLF KZ 05-09X3 EF-ER 16-19X3 KZ 81-09 EF-ER 16-19X3BLF KZ 81-10 ER-14-27X3BLF ER 14-19X3 KZ 05-10X3 ER-14-27X3 ER 14-19X3BLF ER-12-19X3 KZ 05-11X3 ER 12-45X3 ER-12-19X3BLF KZ 81 -11 ER 12-45X3BLF ER 10-37X3 ER 10-37X3BLF ER 10-73X3 ER 10-73X3BLF 25 Multicore cables PERFORMANCES OPERATING TEMPERATURE 200°C and + CONSTRUCTION OPERATING NUMBER OF VOLTAGE CORES 1 000 V CONDUCTOR INSULATION BRAID AWG OUTER JACKET 2 32 30 30 28 28 26 26 24 24 22 Stranded silvered copper PTFE conductor Silvered copper FEP 22 20 20 18 18 16 14 14 12 12 10 10 3 32 30 30 28 28 26 26 24 24 22 Stranded silvered copper conductor PTFE Silvered copper FEP 22 20 20 18 18 16 14 14 12 12 10 10 26 REFERENCES LAYED UP SCREENED DESIGNATION NF MIL FILOTEX SCREENED AND JACKETED DESIGNATION NF MIL FILOTEX DESIGNATION NF KZ 06-01X2 EEF-EER 32-07X2 KZ 71-01 KZ 06-02X2 EEF-EER 30-07X2 KZ 71-02 EEF-EER 30-19X2 KZ 06-03X2 EEF-EER 28-07X2 EEF-EER 26-07X2 KZ 71-03 EEF-EER 24-07X2 KZ 71-04 EEF-EER 22-07X2 KZ 71-05 KZ 71-06 EEF-EER 26-07X2BLF EEF-EER 24-07X2BLF EEF-EER 22-07X2BLF EEF-EER 22-19X2BLF EEF-EER 20-07X2 EEF-EER 20-19X2 EEF-EER 28-07X2BLF EEF-EER 24-19X2BLF EEF-EER 22-19X2 KZ 06-07X2 EEF-EER 30-07X2BLF EEF-EER 26-19X2BLF EEF-EER 24-19X2 KZ 06-06X2 EEF-EER 32-07X2BLF EEF-EER 28-19X2BLF EEF-EER 26-19X2 KZ 06-05X2 FILOTEX EEF-EER 30-19X2BLF EEF-EER 28-19X2 KZ 06-04X2 MIL EEF-EER 20-07X2BLF KZ 71-07 EEF-EER 18-07X2 EEF-EER 20-19X2BLF EEF-EER 18-07X2BLF KZ 06-08X2 EEF-EER 18-19X2 KZ 71-08 EEF-EER 18-19X2BLF KZ 06-09X2 EEF-EER 16-19X2 KZ 71-09 EEF-EER 16-19X2BLF EER 14-19X2 KZ 06-10X2 EER 14-27X2 EER 14-19X2BLF KZ 71-10 EER 12-19X2 KZ 06-11X2 EER 12-45X2 KZ 71-11 EER 10-37X2 KZ 06-02X3 EER 10-73X2BLF EEF-EER 32-07X3 KZ 83-01 EEF-EER 30-07X3 KZ 83-02 EEF-EER 30-19X3 KZ 06-03X3 EEF-EER 28-07X3 EEF-EER 26-07X3 KZ 83-03 EEF-EER-24-07X3 EEF-EER 22-07X3 KZ 83-05 KZ 83-06 EEF-EER-24-07X3BLF EEF-EER 22-07X3BLF EEF-EER 22-19X3BLF EEF-EER 20-07X3 EEF-EER 20-19X3 EEF-EER 26-07X3BLF EEF-EER-24-19X3BLF EEF-EER 22-19X3 KZ 06-07X3 EEF-EER 28-07X3BLP EEF-EER 26-19X3BLF EEF-EER-24-19X3 KZ 06-06X3 EEF-EER 30-07X3BLF EEF-EER 28-19X3BLF KZ 83-04 EEF-EER 26-19X3 KZ 06-05X3 EEF-EER 32-07X3BLF EEF-EER 30-19X3BLF EEF-EER 28-19X3 KZ 06-04X3 EER 12-45X2BLF EER 10-37X2BLF EER 10-73X2 KZ 06-01X3 EER 14-27X2BLF EER 12-19X2BLF EEF-EER 20-07X3BLF KZ 83-07 EEF-EER 18-07X3 EEF-EER 20-19X3BLF EEF-EER 18-07X3BLF KZ 06-08X3 EEF-EER 18-19X3 KZ 83-08 EEF-EER 18-19X3BLF KZ 06-09X3 EEF-EER 16-19X3 KZ 83-09 EEF-EER 16-19X3BLF EER-14-19X3 KZ 06-10X3 EER-14-27X3 EER-14-19X3BLF KZ 83-10 EER-14-27X3BLF KZ 83-11 EER 12-45X3BLF EER 12-19X3 KZ 06-11X3 EER 12-45X3 EER 12-19X3BLF EER 10-37X3 EER 10-37X3BLF EER 10-73X3 EER 10-73X3BLF 27 HT High voltage hook-up wires Filotex® PRODUCTS IN THE RANGE - HT To FILOTEX specification - Operating voltage: 4 000 Volts up to 12 000 Volts R.M.S. - Operating temperature: - 20°C up to + 80°C (ambient temperature + rise) Main characteristics: ■ These wires are designed for flexible connections submitted to a very high voltage. CONSTRUCTION 1 - CONDUCTOR: stranded annealed tinned copper wires 2 - INSULATION: polyethylene 3 ▼ 2 ▼ 1 ▼ 3 - OUTER JACKET: polyvinyl chloride (PVC) UNSCREENED HOOK UP WIRES Cross Reference Gauge section Construction FILOTEX AWG mm2 n x Ø mm Nominal Ø over insulation mm Overall Ø mm Average weight Kg/Km Electrical characteristics Operating voltage V.RMS Test voltage V.CA HT 306 E 20 0.60 19 x 0.20 2.3 3.1 ± 0.2 14 4 000 7 000 HT 406 E 20 0.60 19 x 0.20 3.0 4.2 ± 0.2 20 5 000 10 000 HT 610 E 16 1.34 19 x 0.30 4.5 6.2 ± 0.3 44 7 000 12 000 HT 810 E 16 1.34 19 x 0.30 6.0 8.2 ± 0.3 72 12 000 20 000 Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. CONDUCTOR FM & FMA Screened and jacketed hook-up wires and multicore cables for low frequency applications Filotex® PRODUCTS IN THE RANGE - FM/FMA To FILOTEX specification - Operating voltage: 250 Volts for AWG 24 gauges 750 Volts for AWG 22 gauges - Operating temperature: - 20°C up to + 80°C (ambient temperature + rise) Main characteristics: CONSTRUCTION 1 - CONDUCTOR: stranded tinned copper wires 2 - INSULATION: polyethylene (Pe) or polyvinyl chloride (PVC) according to the products ■ These flexible cables, with a reduced overall diameter (FMA serie), are specially designed for equipment wiring requiring a good efficient screen. ■ Some typical applications: - outdoor and indoor audio installations - microphone connections - wiring in equipment requiring efficient shielding against low frequency interference and inductive coupling. ■ They are flame retardant (to NFC 32070/C2 French specification). 3- SCREEN: tinned copper braid 4- OUTER JACKET: flexible polyvinyl chloride (PVC) 3 4 ▼ NOTA: the items with the FILOTEX reference ending by “PS” only have a PVC sheath as filler between cores and screen ▼ ▼ 2 ▼ 1 SCREENED AND JACKETED HOOK-UP WIRES AND MULTICORE CABLES - SERIE FM&FMA 1 2 3 4 5 6 FM 1R FMA 1R FM 1M FMA 1M FM 1 FMA 1 FM 1P FMA 1P FM 2 R FMA 2 R FM 2 M FMA 2 M FM 2 FMA 2 FM 2 P FMA 2 P FM 2 PS FMA 2 PS FM 3 R FMA 3 R FM 3 FMA 3 FM 3 PS FMA 3 PS FM 4 R FMA 4 R FM 4 FMA 4 FM 4 PS FMA 4 PS FM 5 R FMA 5 R FM 5 FMA 5 FM 6 R FMA 6 R FM 6 FMA 6 CONDUCTOR Nominal Cross Gauge section Construction Ø core mm n x Ø mm mm2 AWG 24 22 22 24 24 22 22 22 24 22 22 24 22 22 24 22 24 22 Overall diameter mini. maxi. mm Average weight Colour coding of cores Kg/Km 0.22 0.22 0.22 0.22 0.38 0.34 0.38 0.34 7 x 0.20 7 x 0.20 7 x 0.20 7 x 0.20 12 x 0.20 7 x 0.25 12 x 0.20 7 x 0.25 1.2 1.1 1.6 1.5 2.5 2.0 2.5 2.0 2,3 2.1 3.3 2.6 4.7 3.2 4.7 3.2 2.7 2.5 3.7 3.0 5.3 3.6 5.3 3.6 12 10 20 14 37 20 35 19 0.22 0.22 0.22 0.22 0.38 0.34 0.38 0.34 0.31 0.34 7 x 0.20 7 x 0.20 7 x 0.20 7 x 0.20 12 x 0.20 7 x 0.25 12 x 0.20 7 x 0.25 40 x 0.10 7 x 0.25 1.2 1.1 1.5 1.5 2.0 2.0 2.0 2.0 2.2 2.0 3.8 3.5 4.7 4.4 5.7 5.3 5.7 5.3 7.7 6.8 4.2 3.9 5.3 4.8 6.3 5.9 6.3 5.9 8.3 7.4 26 23 39 32 54 47 51 44 90 72 0.22 0.22 0.38 0.34 0.31 0.34 7 x 0.20 7 x 0.20 12 x 0.20 7 x 0.25 40 x 0.10 7 x 0.25 1.2 1.1 2.0 2.0 2.2 2.0 4.0 3.7 5.7 5.6 7.8 7.1 4.4 4.1 6.3 6.2 8.6 7.7 32 27 60 60 90 79 0.22 0.22 0.38 0.34 0.31 0.34 7 x 0.20 7 x 0.20 12 x 0.20 7 x 0.25 40 x 0.10 7 x 0.25 1.2 1.1 2.0 2.0 2.2 2.0 5.0 4.0 6.7 6.3 8.1 7.7 5.4 4.4 7.3 6.9 8.9 8.3 38 31 81 67 104 91 0.22 0.22 0.38 0.34 7 x 0.20 7 x 0.20 12 x 0.20 7 x 0.25 1.2 1.1 2.0 2.0 5.6 4.4 7.7 7.1 6.0 4.8 8.3 7.7 48 37 101 84 White, Blue, Red, Yellow, Green 0.22 0.22 0.38 0.34 7 x 0.20 7 x 0.20 12 x 0.20 7 x 0.25 1.1 1.1 2.0 2.0 5.0 4.7 8.3 7.7 5.6 5.1 9.1 8.5 43 41 106 93 White, Blue Red, Yellow, Green, Black White White Natural White, Blue White, Yellow White, Blue Natural, Red White, Yellow White, Blue, Red White, Yellow, Green White, Blue, Red, Yellow White, Yellow Green, Blue The cables with the letter “P” in the reference (example FMA 2P) have the polyethylene insulated cores, the other cables have the PVC insulated cores. Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. BASE CORE Number Reference of FILOTEX cores EHE & EHEA Screened and jacketed hook-up wires and multicore cables for low frequency applications Filotex® PRODUCTS IN THE RANGE - EHE/EHEA To FILOTEX specification - Operating voltage: 250 Volts and 750 Volts according to the products - Operating temperature: - 20°C up to + 80°C (ambient temperature + rise) Main characteristics: CONSTRUCTION 1 - CONDUCTOR: stranded tinned copper wires ■ These flexible cables are designed mainly for use in applications requiring high efficiency screening at low frequencies. The screen is made up of a continuous high conductive thermoplastic sheath and provides a shielding efficiency inversely proportional to the frequency. So a very high efficiency is obtained at industrial frequencies. ■ Easy stripping, as well as grounding, because of the drain wire placed under the thermoplastic sheath. ■ They are flame retardant (to NFC 32070/C2 French specification) 2 - INSULATION: polyethylene (Pe) 3- DRAIN WIRE 4- SCREEN: high conductive sheath 5- OUTER JACKET: flexible polyvinyl chloride (PVC) 5 ▼ 4 ▼ 3 ▼ ▼ 2 ▼ 1 SCREENED AND JACKETED HOOK UP WIRES AND MULTICORE CABLES - SERIE EHE & EHEA BASE CORE Reference FILOTEX CONDUCTOR Gauge Cross Construction section n x Ø mm AWG mm2 Overall diameter Nominal Ø core mini. maxi. mm mm Average Operating weight voltage Colour coding of cores Kg/Km EHE 1 PR EHEA 1 PR EHEA 1 PM 24 0,22 0,22 0,22 7 x 0,20 7 x 0,20 7 x 0,20 1,2 1,1 1,5 2,6 2,4 3,0 3,0 2,8 3,4 10 9 12 250 V EHEA 1 P 22 0,34 7 x 0,25 2,0 3,4 3,8 15 750 V EHE 2 PR EHEA 2 PR 24 0,22 0,22 7 x 0,20 7 x 0,20 1,2 1,1 3,8 3,5 4,2 3,9 17 16 250 V EHEA 2 PM 24 0,22 7 x 0,20 1,5 4,6 5,0 22 250 V EHE 2 PM 22 0,34 7 x 0,25 1,5 4,7 5,3 25 250 V EHE 2 P EHEA 2 P 22 0,38 0,34 12 x 0,20 7 x 0,25 2,0 2,0 5,5 5,5 6,1 6,1 29 29 750 V Natural Blue EHE 3 PR EHEA 3 PR 24 0,22 0,22 7 x 0,20 7 x 0,20 1,2 1,1 4,0 3,8 4,4 4,2 21 19 250 V Natural ,Blue Red EHEA 3 PM 24 0,22 7 x 0,20 1,5 4,8 5,4 26 250 V Natural ,Blue Yellow EHE 3 P 22 0,38 12 x 0,20 2,0 6,4 7,0 44 750 V Natural ,Blue Red EHE 4 PR EHEA 4 PR EHEA 4 PM 24 0,22 0,22 0,22 7 x 0,20 7 x 0,20 7 x 0,20 1,2 1,1 1,5 4,6 4,2 5,2 5,0 4,6 5,8 26 23 32 250 V EHE 4 PM 22 0,34 7 x 0,25 1,5 5,5 6,1 40 250 V 5 EHEA 5 PR 24 0,22 7 x 0,20 1,1 4,6 5,0 28 250 V Natural ,Blue Red, Yellow, Green 6 EHEA 6 PR 24 0,22 7x 0,20 1,1 4,9 5,3 32 250 V Natural ,Blue, Red, Yellow, Green, Black 1 2 3 4 Natural Natural Blue Natural Yellow Natural ,Blue Red, Yellow Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Number of cores ELECTRONIC Passing on or copying of the document, use or communicate of its content is not permitted without prior writte n authorization. Information subject to change without notice. Filotex ® PRODUCTS IN THE RANGE - SMA (unscreened cables) - SMBL (screened cables) SMA & SMBL Unscreened and jacketed (SMA), screened and jacketed (SMBL) multicore cables To NEXANS specification r Operating voltage: 500 Volts RMS r Operating temperature: - 20° C up to + 80°C (ambient temperature + rise). Main characteristics r Flexible cables designed for internal wiring in equipment, found in widely varying markets (instrumentation, process-control, remote control, electronic industrial equipment,...) r They are flame retardant (to NFC 32070/C2 French specification). CONSTRUCTION 1- CONDUCTOR: stranded tinned copper wires 2- INSULATION: flexible polyvinyl chloride (PVC) 3- LAY UP: polyester tape (for screened cables only) 4- SCREEN: tinned copper braid 5- OUTER JACKET: polyvinyl chloride (PVC) (for SMA and SMBL) colour coding of the cores by plain colours and rings 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 2 12/09/2001 UNSCREENED AND JACKETED MULTICORE CABLE - SERIE SMA Cross section 0,22 mm2 (AWG24) ∅ +/Average weight mm Kg/Km Nb. of cores Reference Filotex 2 3 4 5 7 10 12 19 27 37 SMA 02x... SMA03x... SMA 04x... SMA05x... SMA07x... SMA 10x... SMA12x... SMA19x... SMA 27x... SMA37x... 3.10 3.30 3.70 3.90 4.20 5.55 5.70 6.40 7.80 8.50 0.15 0.15 0.15 0.15 0.15 0.20 0.20 0.20 0.25 0.25 11.33 14.84 19.37 22.13 28.98 43.85 49.99 70.30 100.83 129.11 Cross section 0,34 mm2 (AWG22) ∅ +/Average weight mm Kg/Km 3.70 3.80 4.25 4.60 5.00 6.25 6.35 7.50 9.50 10.00 0.15 0.15 0.15 0.15 0.15 0.20 0.20 0.25 0.25 0.25 16.60 20.70 27.00 32.13 42.74 59.41 67.34 102.14 153.58 188.88 Cross section 0,60 mm2 (AWG20) ∅ +/Average weight mm Kg/Km 4.25 4.70 5.30 5.80 6.25 8.15 8.35 9.70 11.50 13.50 0.15 0.15 0.20 0.20 0.20 0.20 0.25 0.25 0.25 0.30 28.21 36.87 47.33 56.32 72.61 99.56 114.42 170.20 234.71 330.92 SCREENED AND JACKETED MULTICORE CABLES - SERIE SMBL Nb. of cores Reference Filotex 2 3 4 5 7 10 12 19 27 37 SMBL 02x... SMBL03x... SMBL 04x... SMBL05x... SMBL07x... SMBL 10x... SMBL12x... SMBL19x... SMBL 27x... SMBL37x... Cross section 0,22 mm 2 (AWG24) ∅ +/- Average weight mm Kg/Km 3,60 3.80 4.10 4.40 4.90 6.00 6.10 7.05 8.75 9.45 0.15 0.15 0.15 0.15 0.15 0.15 0.20 0.25 0.25 0.25 Cross section 0,34 mm2 ∅ (AWG22) +/Average weight mm Kg/Km 19.89 4.40 23.81 4.55 29.24 5.00 32.40 5.65 45.29 5.80 57.49 7.25 63.33 7.30 90.77 8.50 129.78 9.90 160.87 11.10 0.15 0.15 0.15 0.20 0.20 0.25 0.25 0.25 0.25 0.30 Cross section 0,60 mm2 ∅ (AWG20) +/Average weight mm Kg/Km 25.41 5.10 30.96 5.40 38.59 5.90 49.38 6.50 61.40 6.90 81.94 8.90 91.28 8.90 131.16 10.55 175.04 12.80 229.01 14.30 0.20 0.20 0.20 0.20 0.20 0.25 0.25 0.30 0.30 0.30 34.69 45.83 57.01 68.84 92.43 126.59 141.95 205.2 294.79 384.18 Cross section 0,93 mm2 ∅ (AWG18) +/Average weight mm Kg/Km 5.75 6.00 6.80 7.30 8.00 10.20 10.30 12.10 14.90 16.40 0.20 0.20 0.20 0.25 0.25 0.30 0.30 0.30 0.30 0.35 46.63 65.11 78.38 93.45 122.12 174.41 194.36 287.34 418.65 539.74 Cross section 1,34 mm2 ∅ (AWG16) +/Average weight mm Kg/Km 6.30 6.65 7.40 8.20 9.00 11.60 11.70 14.30 17.40 19.50 0.20 0.20 0.25 0.25 0.25 0.30 0.30 0.30 0.35 0.40 DESCRIPTION OF CORE CONDUCTOR Cross section Gauge Construction mm2 AWG n x Ø mm 0.22 24 7 x 0.20 0.34 22 7 x 0.25 0.60 20 19x 0.20 0.93 18 19 x 0.25 1.34 16 19 x 0.30 Ø Insulation mm 1.04 1.24 1.65 1.90 2.27 COLOUR CODING OF CORES SMA/SMBL Core. n° Plain colour Core n° Plain colour/ Ring colour Core. n° Plain colour Core n° Plain colour/ Ring colour 1 2 3 4 5 6 7 8 9 10 White Light Blue Yellow Brown Black Red Green Grey Orange Purple 11 12 13 14 15 16 17 18 19 20 White/Blue White/Yellow White/Brown White/Black White/Red White/Green White/Grey White/Orange White/Purple White/Yellow 21 22 23 24 25 26 27 28 29 30 Blue/Brown Blue/Black Blue/Red Blue/Green Blue/Grey Blue/Orange Blue/Purple Yellow/Brown Yellow/Black Yellow/Red 31 32 33 34 35 36 37 Yellow/Green Yellow/Grey Yellow/Orange Yellow/Purple Brown/Black Brown/Red Brown/Green 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 2 12/09/2001 57.47 76.39 99.80 121.82 160.78 230.88 258.8 409.74 576.29 759.42 GRTH & CCTB Unscreened and jacketed (GRTH), screened and jacketed (CCTB) multicore cables Filotex® PRODUCTS IN THE RANGE - GRTH (unscreened cables) - CCTB (screened cables) To FILOTEX specification - Operating voltage: 750 Volts R.M.S. - Operating temperature: - 20°C up to + 80°C (ambient temperature + rise) Main characteristics: ■ Flexible cables designed for internal wiring in equipment, operating at a maximum voltage of 750 V RMS, found in widely varying markets (instrumentation, process-control, remote control, electronic industrial equipment...) ■ They are flame retardant (to NFC 32070/C2 French specification) CONSTRUCTION 1 - CONDUCTOR: stranded tinned copper wires 2 - INSULATION: flexible polyvinyl chloride (PVC) 3- LAY UP: polyester tape (for screened cables only) 5 ▼ 4 ▼ ▼ 3 5- OUTER JACKET: polyvinyl chloride (PVC) (for GRTH and CCTB). Colour coding of the cores by plain colours and rings. ▼ 2 ▼ 1 4- SCREEN: tinned copper braid UNSCREENED AND JACKETED MULTICORE CABLES - SERIE GRTH Reference Filotex Cross section 0,93 mm2 (AWG 18) Cross section 0,60 mm2 (AWG 20) overall Diameter Average overall Diameter mini. maxi. weight mini. maxi. mm Kg/Km mm Average weight overall Diameter Kg/Km mm overall Diameter Average weight maxi. mini. Cross section 1,34 mm2 (AWG 16) maxi. mini. Kg/Km mm Average weight Cross section 1,91 mm2 (AWG 14) overall Diameter mini. maxi. mm Kg/Km Average weight Kg/Km 2 GRTH 02x... 5.3 5.7 38.3 5.7 6.3 48 6.9 7.5 71 7.3 7.9 81 8.0 8.6 104 3 GRTH 03x... 5.6 6.0 44.6 6.2 6.8 59 7.3 7.9 83 7.7 8.3 100 9.1 9.7 139 4 GRTH 04x... 6.1 6.7 53.8 6.7 7.3 69 8.2 8.8 104 8.6 9.2 124 9.9 10.5 167 7 GRTH 07x... 7.5 8.1 90.8 8.1 8.7 106 9.2 9.8 144 9.8 10.4 192 11.0 11.6 253 11.3 11.9 175 12.6 13.2 239 13.6 14.2 303 15.2 15.8 397 12 GRTH 12x... 10.3 10.9 139 SCREENED AND JACKETED MULTICORE CABLES - SERIE CCTB 2 Nb. of cores Reference Filotex mini. maxi. mm 2 Cross section 1,34 mm (AWG 16 Cross section 0,93 mm (AWG 18) overall Diameter Average overall Diameter mini. maxi. weight Kg/Km mm 2 2 Cross section 0,60 mm (AWG 20) Average weight overall Diameter mini. maxi. mm Cross section 1,91 mm (AWG 14) Average weight overall Diameter mini. maxi. Average weight Kg/Km mm Kg/Km 2 CCTB 02x... 6.2 6.8 61.2 6.8 7.4 Kg/Km 76 3 CCTB 03x... 6.5 7.1 71 7.3 7.9 92 4 CCTB 04x... 7.4 8.0 89 8.2 8.8 115 8.8 9.4 140 9.8 10.4 177 5 CCTB 05x... 8.2 8.8 103 9.0 9.6 131 9.8 10.4 163 10.8 11.4 205 CCTB 07x... 9.0 7 7.3 7.9 91 8.3 8.9 119 8.0 8.6 115 8.9 9.5 145 9.6 131 10.1 10.7 171 10.7 11.3 206 11.9 12.5 264 10 CCTB 10x... 11.7 12.3 188 13.1 13.7 245 14.0 14.6 298 15.8 16.6 404 12 CCTB 12x... 12.1 12.7 213 13.5 14.1 278 14.5 15.1 342 16.3 17.1 460 19 CCTB 19x... 14.4 15.0 312 16.3 17.1 433 17.3 18.3 534 19.7 20.5 710 COLOUR CODING OF CORES GRTH/CCTB DESCRIPTION OF CORE Ø Conductor Cross section Gauge Construction mm2 AWG n x Ø mm of core mm Core n° Plain colour Core n° Plain/Ring colour/colour 1 Black 11 White/Brown* 0,34 22 7 x 0,25 2,15 ± 0,15 2 Light Blue 12 White/Grey* 0,60 20 19 x 0,20 2,35 ± 0,15 3 Brown* 13 White/Orange* 0,93 18 19 x 0,25 2,65 ± 0,15 4 Grey* 14 White/Red* 1,34 16 19 x 0,30 2,85 ± 0,15 5 Orange* 15 White/Purple* 1,91 14 27 x 0,30 3,20 ± 0,20 6 Red* 16 White/Brown* 7 Purple* 17 Blue/Grey* 8 White* 18 Blue/Orange* 19 Yellow/Green* - Example of ordering : GRTH 02 x 0,34 ; CCTB 19 x 0,93 9 White/Black* 10 White/Blue* * From 3 cores the last one is Yellow/Green - Example for 3 cores : Black, Light Blue, Yellow/Green Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Nb. of cores Cross section 0,34 mm2 (AWG 22) KY/EPDX Unscreened hook-up wires Filotex® PRODUCTS IN THE RANGE - KY/EPDX To NFC 93521 & NFC 32070/C1 French specifications - Operating voltage: 250 and 750 Volts - Operating temperature: – 40°C up to + 105°C (ambient temperature + rise) Main characteristics: ■ These wires are mainly designed for internal wiring in electronic equipment. ■ They are fire retardant (to NFC 32 070/C1 French specification) CONSTRUCTION 1- CONDUCTOR: Solid (KY31A) or stranded (KY30 & KY33A) annealed tinned copper wires 2 ▼ 1 ▼ 2- INSULATION: High temperature polyvinyl chloride (PVC) UNSCREENED HOOK-UP WIRES Overall Diameter mini. maxi. mm Average weight Kg/Km TYPE KY - Serie 250 Volts - Stranded conductor KY 30-01 EPDX 6x0 30 0.055 7 x 0.10 0.70 0.80 1.0 KY 30-02 EPDX 5x0 28 0.079 7 x 0.12 0.76 0.86 1.3 KY 30-03 EPDX 4x0 26 0.12 7 x 0.15 0.80 1.00 1.8 KY 30-04 EPDX 000 24 0.22 7 x 0.20 1.00 1.20 3.0 KY 30-05 EPDX 00 22 0.34 7 x 0.25 1.20 1.45 4.4 KY 30-06 EPDX 26 20 0.60 19 x 0.20 1.60 1.90 7.7 KY 30-07 EPDX 27 18 0.93 19 x 0.25 1.85 2.15 11.3 KY 30-08 EPDX 28 16 1.34 19 x 0.30 2.20 2.50 16.0 - EPDX 29 14 1.91 27 x 0.30 2.55 2.85 22.0 - EPDX 100 12 3.18 45 x 0.30 3.20 3.60 36.0 - EPDX 140 10 5.16 73 x 0.30 3.90 4.30 56.6 TYPE KY - Serie 750 Volts - Solid conductor KY 31 A-01 EPDX 1 22 0.28 1 x 0.60 1.60 1.80 5.3 KY 31 A-02 EPDX 2 20 0.50 1 x 0.80 2.00 2.30 8.6 KY 31 A-03 EPDX 3 18 1.10 1 x 1.18 2.35 2.65 14.8 KY 31 A-04 EPDX 4 14 2.00 1 x 1.60 2.80 3.10 24.3 KY 31 A-05 EPDX 5 12 3.14 1 x 2.00 3.20 3.60 35.8 TYPE KY - Serie 750 Volts - Standed conductor KY 33 A-01 EPDX 6 24 0.22 7 x 0.20 1.60 1.80 4.7 KY 33 A-02 EPDX 7 22 0.38 12 x 0.20 2.00 2.30 7.7 KY 33 A-03 EPDX 16 20 0.60 19 x 0.20 2.20 2.50 10.3 KY 33 A-04 EPDX 17 18 1.00 32 x 0.20 2.50 2.80 14.9 KY 33 A-05 EPDX 8 16 1.34 19 x 0.30 2.70 3.00 18.7 KY 33 A-06 EPDX 9 14 1.91 27 x 0.30 3.00 3.40 25.0 KY 33 A-07 EPDX 10 12 3.18 45 x 0.30 3.80 4.20 40.6 KY 33 A-08 EPDX 14 10 5.15 73 x 0.30 4.40 4.80 60.7 EPDX 18 9 7.40 105 x 0.30 5.00 5.40 83.7 KY 33 A-09 EPDX 15 8 10.20 144 x 0.30 5.80 6.20 114.0 KY 33 A-10 EPDX 19 4 24.70 126 x 0.50 9.60 10.20 290.0 Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. CONDUCTOR Reference Reference Construction NFC 93 521 FILOTEX Gauge Cross section n x Ø mm mm2 AWG KY/EPDX Screened hook-up wires, screened and jacketed hook-up wires Filotex® PRODUCTS IN THE RANGE - KY/EPDX To NFC 93521 & NF C 32070 C1 French specifications - Operating voltage : 250 volts and 750 volts - Operating temperature: – 40°C up to + 105°C (ambient temperature + rise) Main characteristics: ■ Applications: internal wiring in electronic equipment. ■ They are fire retardant (to NFC 32070/C1 French specification). CONSTRUCTION 1- CONDUCTOR: stranded annealed tinned copper wires 2- INSULATION: high temperature polyvinyl chloride (PVC) 3- SCREEN: tinned copper braid 4 ▼ 3 ▼ 2 ▼ 1 ▼ 4- OUTER JACKET: polyvinyl chloride (PVC), or superpolyamide (P) SCREENED HOOK-UP WIRES BASE CORE CONDUCTOR Nominal Ø Cross Construction Gauge section core AWG mm2 n x Ø mm mm Reference FILOTEX Overall Diameter Braid Average weight Ø strands mm kr % mini 0.90 1.10 1.30 0.10 0.10 0.10 55 55 60 1.2 1.4 1.6 1.7 1.9 2.2 4.8 6.6 8.5 1.70 2.15 2.35 2.65 2.85 3.20 0.10 0.12 0.12 0.12 0.12 0.12 60 65 65 65 65 70 1.9 2.4 2.6 2.9 3.1 3.4 2.4 3.1 3.3 3.6 3.8 4.2 10.2 16.5 19.9 25.5 30.2 39.0 maxi Kg/Km mm TYPE KY - 250 Volts - Stranded conductor 1 1 1 KY 45-01 KY 45-02 KY 45-03 EPDX 4x0 BL EPDX 000 BL EPDX 00 BL 26 24 22 0.12 0.22 0.34 7 x 0.15 7 x 0.20 7 x 0.25 TYPE KY - 750 Volts - Stranded conductor 1 1 1 1 1 1 KY 37 A-01 KY 37 A-02 KY 37 A-03 KY 37 A-04 KY 37 A-05 KY 37 A-06 EPDX 6 BL. EPDX 7 BL EPDX 16 BL EPDX 17 BL EPDX 8 BL EPDX 9 BL 24 22 20 18 16 14 0.22 0.38 0.60 1.00 1.34 1.91 7 x 0.20 12 x 0.20 19 x 0.20 32 x 0.20 19 x 0.30 27 x 0.30 SCREENED AND JACKETED HOOK-UP WIRES BASE CORE Braid Nb CONDUCTOR Reference Nominal Reference of Ø Ø NFC 93-521 FILOTEX Gauge Cross Construction kr cores core strands section % mm AWG mm2 n x Ø mm mm Overall Diameter Outer jacket nature mini maxi Average weight Kg/Km mm TYPE KY - 250 volts - Stranded conductor 1 1 1 KY 46-01 KY 46-02 KY 46-03 EPDX 4x0 BL.P EPDX 3x0 BLP EPDX 00 BLP 26 24 22 0.12 0.22 0.34 7 x 0.15 7 x 0.20 7 x 0.25 0.90 1.10 1.30 0.10 0.10 0.10 55 55 60 P P P 1.4 1.6 1.8 2.1 2.3 2.6 5.2 7.4 9.5 1,7 1,7 2,15 2,15 2,35 2,35 2,65 2,65 2,85 2,85 3,20 3,20 0,10 0,10 0,12 0,12 0,12 0,12 0,12 0,12 0,12 0,12 0,12 0,12 60 60 65 65 65 65 65 65 65 65 70 70 PVC P PVC P PVC P PVC P PVC P PVC P 3,1 2,1 3,6 2,6 3,8 2,8 4,1 3,1 4,3 3,3 4,6 3,6 3,8 2,8 4,5 3,5 4,7 3,7 5,0 4,0 5,2 4,2 5,5 4,6 18,1 11,2 26,2 17,7 30.0 21,2 36,6 26,9 41,9 31,7 51,4 40,6 TYPE KY - 750 volts - Stranded conductor 1 1 1 1 1 1 1 1 1 1 1 1 KY 41 A-01 KY 44 A-01 KY 41 A-02 KY 44 A-02 KY 41 A-03 KY 44 A-03 KY 41 A-04 KY 44 A-04 KY 41 A-05 KY 44 A-05 KY 41 A-06 KY 44 A-06 EPDX 6 BLI EPDX 6 BLP EPDX 7 BLI EPDX 7 BLP EPDX 16 BLI EPDX 16 BLP EPDX 17 BLI EPDX 17 BLP EPDX 8 BLI EPDX 8 BLP EPDX 9 BLI EPDX 9 BLP 24 24 22 22 20 20 18 18 16 16 14 14 0,22 0,22 0,38 0,38 0,60 0,60 1,0 1,0 1,34 1,34 1,91 1,91 7 x 0,20 7 x 0,20 12 x 0,20 12 x 0,20 19 x 0,20 19 x 0,20 32 x 0,20 32 x 0,20 19 x 0,30 19 x 0,30 27 x 0,30 27 x 0,30 Reference.. BLI: PVC outer jacket giving a good mechanical protection and electrical insulation Reference.. BLP: Superpolyamide outer jacket providing only a mechanical protection Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Nb Reference of NFC 93-521 cores KY/EPDX Unscreened pairs, screened pairs, screened and jacketed pairs Filotex® PRODUCTS IN THE RANGE - KY/EPDX To NFC 93521 and NFC 32070/C1 French specifications - Operating voltage: 250 volts and 750 Volts - Operating temperature: – 40°C up to + 105°C (ambient temperature + rise) Main characteristics: ■ Applications: internal wiring in electronic equipment. ■ They are fire retardant (to NFC 32 070/C1 French specification). CONSTRUCTION 1- CONDUCTOR: stranded annealed tinned copper wires 2- INSULATION: high temperature polyvinyl chloride (PVC) 3- SCREEN: tinned copper braid 4 ▼ ▼ 3 1 2 ▼ { Base core ▼ 4- OUTER JACKET: polyvinyl chloride (PVC), or superpolyamide (P) UNSCREENED PAIRS BASE CORE CONDUCTOR Gauge Cross Construction section AWG mm2 n x Ø mm Reference FILOTEX TYPE KY - 250 Volts - Stranded conductor 2 EPDX 4 x 0 x 2 26 0.12 7 x 0.15 2 EPDX 000 x 2 24 0.22 7 x 0.20 2 EPDX 00 x 2 22 0.34 7 x 0.25 Nominal Ø core mm Ø over lay up of cores mm Average weight 0.90 1.10 1.30 1.80 2.20 2.60 3.7 6.1 8.9 2.35 4.70 22.8 Kg/Km TYPE KY - 750 Volts - Stranded conductor 2 - EPDX 16 x 2 20 0.60 19 x 0.20 SCREENED PAIRS BASE CORE Nb CONDUCTOR Reference Reference of NFC 93-521 FILOTEX Gauge Cross Construction cores section AWG mm2 n x Ø mm Nominal Ø core mm Braid Ø over lay up Ø of cores strands kr % mm mm Outer jacket nature Overall Diameter mini. maxi. Average weight Kg/Km mm TYPE KY - 250 Volts - Stranded conductor 2 KY 93-01 DX 4x0 BL 26 0.12 7 x 0.15 0.90 1.80 0.10 60 - 1.9 2.7 10.8 2 KY 93-02 DX 000BL 24 0.22 7 x 0.20 1.10 2.20 0.10 60 - 2.3 3.1 15.0 2 KY 93-03 DX 00 BL 22 0.34 7 x 0.25 1.30 2.60 0.12 65 - 2.8 3.8 18.0 TYPE KY - 750 volts - Stranded conductor 2 KY 70 A-01 DX 7 BL 22 0.38 12 x 0.20 2.15 4.3 0.12 70 - 4.5 5.4 31.3 2 KY70 A-02 DX 8 BL 16 1.34 19 x 0.30 2.85 5.7 0.12 75 - 5.9 6.8 60.0 SCREENED AND JACKETED PAIRS TYPE KY - 250 Volts - Stranded conductor 2 2 2 2 2 KY91-01 KY91-02 KY91-03 - DX 4x0 BL.P DX 000 BL.P 26 24 0.12 0.22 7 x 0.15 7 x 0.20 0.90 1.10 1.80 2.20 0.10 0.10 60 60 P P 2.1 2.5 3.1 3.5 12.1 16.0 DKY30-04 BLBV 24 0.22 7 x 0.20 1.10 2.20 0.10 60 PVC 2.6 3.7 18.2 DX00 BLP DKY30-05 BLBV 22 22 0.34 0.34 7 x 0.25 7 x 0.25 1.30 1.30 2.60 2.60 0.12 0.12 65 65 P PVC 3.0 3.0 4.2 4.2 19.4 22.2 TYPE KY - 750 Volts - Stranded conductor 2 2 2 KY83 A-01 KY83 A-02 - 2 - 2 - 2 2 KY83 A-03 - DX 6 BLP 24 DX 7 BLP 22 DKY33A-02 22 BLBV DKY33A-03 20 BLBV DKY33A-04 18 BLBV DX 8 BL.P 16 DKY33A-05 16 BLBV 0.22 0.38 0.38 7 x 0.20 12 x 0.20 12 x 0.20 1.70 2.15 2.15 3.40 4.30 4.30 0.12 0.12 0.12 65 70 70 P P PVC 3.9 4.7 4.7 4.8 5.8 5.8 23.5 34.0 40.6 0.60 19 x 0.20 2.35 4.70 0.12 65 PVC 5.1 6.2 42.7 1.00 32 x 0.20 2.65 5.30 0.12 65 PVC 5.8 6.9 58.3 1.34 1.34 19 x 0.30 19 x 0.30 2.85 2.85 5.70 5.70 0.12 0.12 75 75 P PVC 6.1 6.1 7.2 7.2 63.6 69.9 Reference.. BLP: superpolyamide outer jacket providing only a mechanical protection Reference.. BLBV: PVC outer jacket providing a good mechanical protection and electrical insulation Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Nb Reference of NFC 93-521 cores Filotex® PRODUCTS IN THE RANGE - KY/EPDX KY/EPDX Unscreened triples, screened triples, screened and jacketed triples To NFC 93521 & NFC 32070/C1 French specifications - Operating voltage: 250 Volts and 750 Volts - Operating temperature: – 40°C up to + 105°C (ambient temperature + rise) Main characteristics: ■ Applications: international wiring in electronic equipment. ■ They are fire retardant (to NFC 32 070/C1 French specification). CONSTRUCTION 1- CONDUCTOR: stranded annealed tinned copper wires 2- INSULATION: hight temperature polyvinyl chloride (PVC) . 3- SCREEN: tinned copper braid 4- OUTER JACKET polyvinyl chloride (PVC) or superpolyamide (P) 4 ▼ 3 ▼ ▼ 2 ▼ 1 UNSCREENED TRIPLE Reference FILOTEX BASE CORE Ø over CONDUCTOR Nominal lay up Average Ø of cores weight Gauge Cross Construct. core section 2 Kg/Km mm mm AWG mm n x Ø mm TYPE KY- 250 Volts - Stranded conductor 3 - TKY 30-05 22 0.34 7 x 0.25 1.30 2.8 14.5 SCREENED TRIPLES BASE CORE Braid Ø over Nb CONDUCTOR Nominal lay up Reference Reference of Ø Ø NFC 93-521 FILOTEX Gauge Cross Construct. of cores Strands kr cores core section n x Ø mm % mm AWG mm2 mm mm Outer jacket nature Overall diameter mini maxi mm Average weight Kg/Km TYPE KY- 250 volts - Stranded conductor 3 KY 94-01 TX 4x0 BL 26 0.12 7x 0.15 0.90 2.0 0.10 60 - 2.0 2.8 13.1 3 KY 94-02 TX 000BL 24 0.22 7 x 0.20 1.10 2.4 0.10 60 - 2.4 3.2 18.8 3 KY 94-03 TX 00 BL 22 0.34 7 x 0.25 1.30 2.8 0.12 65 - 3.0 4.0 22.2 0.12 75 - 4.8 5.8 43.7 TYPE KY- 750 volts - Stranded conductor 3 KY 72 A01 TX 7 BL 22 0.38 12 x 0.20 2.15 4.6 SCREENED AND JACKETED TRIPLES TYPE KY- 250 Volts - Stranded conductor 3 3 KY92-01 KY92-02 TX 4x0 BLP 26 TX 000 BLP 24 0,12 0,22 7x 0,15 7 x 0,20 0,90 1,10 2,0 2,4 0,10 0,10 60 60 P P 2,2 2,6 3,3 3,7 14,4 20,5 3 3 KY92-03 - TX00 BLP TKY30-05 BLBV 0,34 0,34 7 x 0,25 7 x 0,25 1,30 1,30 2,8 2,8 0,12 0,12 65 65 P P 3,2 3,2 4,4 4,4 24,0 31,1 22 22 TYPE KY- 750 Volts - Stranded conductor 3 3 3 KY84 A-01 KY84 A-02 - TX 6 BLP 24 TX 7 BLP 22 TKY33A-03 20 BLB V 0.22 7 x 0.20 034 7 x 0.25 0.60 19 x 0.20 1.70 2.15 2.35 3.7 4.6 5.0 0.12 0.12 0.12 70 75 65 P P P 4.1 5.0 5.4 5.1 6.2 6.6 31.7 46.5 60.7 3 - 1.00 32 x 0.20 2.65 5.7 0.12 65 P 6.1 7.3 83.5 3 KY84 A-03 TKY33A-04 18 BLB V TX 8 BLP 16 1.34 2.85 6.2 0.15 75 P 6.5 7.7 94.3 19 x 0.30 Reference:... BLP: superpolyamide outer jacket providing only a mechanical protection Reference:... BLBV: PVC outer jacket providing a good mechanical protection and electronical insulation Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Nb Reference of NFC 93-521 cores 1604 Unscreened hook-up wires Filotex® PRODUCTS IN THE RANGE - 1604 - 604 To AIR 4524 and MIL.W 5086 B/7A specifications These cables are approved by the Air Ministry under letters: N° 41762 STA/EQ/E2 (12-11-68) for AWG22 up to AWG 8 N° 33587 STA/EQ/E2 (30-3-72) for AWG24 Registered at B.N.Aé: N° 6412 411 A Operating voltage: 600 Volts RMS Operating temperature: – 40°C up to + 105°C (ambient temperature + rise) Main characteristics: ■ Flexible cables and lightweight serie with PVC + superpolyamide 3- OUTER JACKET: superpolyamide (radial thickness: from 0,10 mm up to 0,15 mm) ■ Air 4524 specification of September 1965 - The 105/135°C category. ■ NFL 52-120B - BNAé specification of December 1971 - Lightweight cables. ■ Colour coding: to AIR 0107A specification of October 1961. Interchangeability: ■ MIL-W-5086 B/7 U.S. specification (December 1970). ■ AICMA N° 5102 specification (December 1962). 1 2 3 ▼ 2- INSULATION: polyvinyl chloride (PVC) Technical requirements and control conditions: ▼ 1- CONDUCTOR: stranded tinned copper wires or stranded tinned copper alloy wires for the cross section area 0,21 mm2 insulation for use in low temperature areas ■ Abrasion resistance: good. ■ They are fire retardant (to NFC 32070/C1 French specification). ■ They withstand most chemical fluids except for concentrated nitric acid. ▼ CONSTRUCTION UNSCREENED HOOK-UP WIRES Reference FILOTEX CORE D.C Resist Current Overall Average at 20°C rating Nominal Tensile Construction A Ø strength diameter weight maxi n x Ø mm mm mm daN. Kg/Km Ω/Km Colour of cores 1604 - 0.21 - G 24 19 x 0.12 0.60 7 1.38 ± 0.07 3.4 105.0 4 Light Blue 1604 - 0.38 - G 22 12 x 0.20 0.80 8 1.50 ± 0.07 5.1 50.9 7 White 1604 - 0.60 - G 20 19 x 0.20 1.00 16 1.70 ± 0.07 7.5 32.2 11 Light Blue 1604 - 0.93 - G 18 19 x 0.25 1.20 20 2.0 ± 0.07 11.0 20.6 16 White 1604 - 1.34 - G 16 19 x 0.30 1.50 20 2.30 ± 0.10 14.0 14.3 22 Light Blue 1604 - 1.91 - G 14 27 x 0.30 1.80 20 2.70 ± 0.10 21.6 10.1 32 White 1604 - 3.18 - G 12 45 x 0.30 2.30 20 3.50 ± 0.10 36.1 6.0 41 White 1604 - 5.15 - G 10 73 x 0.30 3.00 20 4.20 - 0.20 55.1 3.7 55 White 1604 - 8.98 - G 8 127 x 0.30 3.80 20 5.50 - 0.20 90.2 2.1 75 White ■ The shown current rating is valid for singles wires in air + 0.10 + 0.10 Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. CONDUCTOR 604 Screened and jacketed hook-up wires and multicore cables Filotex® PRODUCTS IN THE RANGE - 1604 - 604 To AIR 4524 & MIL-W 5086B/7A specifications These cables are approved by the Air Ministry under letters: N° 33587 STA/EQ/E2 (30-3-72) for AWG 24 N° 41762 STA/EQ/E2 (12-11-68) for AWG 22 up to AWG 8 Registered at B.N.Aé : N° 6412 411 A Operating voltage : 600 Volts RMS Operating temperature: – 40°C up to + 105°C (ambient temperature + rise) Main characteristics : ■ Flexible cables and lightweight serie with PVC + superpolyamide 1604 604 4- LAY UP: 1 or several 1604 cores 6- OUTER JACKET: superpolyamide (radial thickness: about 0,20mm) 2 3 4 5 6 ▼ 5- SCREEN: tinned copper braid (Kr ≥ 62%) 1 ▼ 3- OUTER JACKET: superpolyamide (radial thickness: from 0,10 mm up to 0,15 mm) ▼ 2- INSULATION: polyvinyl chloride (PVC ). ■ Screen: to MIL.C. 7078C (August 1971) U.S. spécification ■ Colour coding: to Air 0107 A (october 1961) and note N° 348/SIB distributed under n° 5927/STT/SIB (3 mai 1961). ▼ 2 Technical requirements and control conditions: ▼ 1- CONSTRUCTION: stranded tinned copper wires or stranded tinned copper alloy wires for cross section 0,21mm . ▼ BASE CORE: 1604 insulation for use in low temperature areas ■ Abrasion resistance: good. ■ They are fire retardant (to NFC 32070/C1 French specification). ■ They withstand most chemical fluids except for concentrated nitric acid. } CONSTRUCTION SCREENED AND JACKETED HOOK UP WIRES AND MULTICORE CABLES Reference FILOTEX SERIE 604 Construction n x Ø mm Overall Diameter nominal mm Colour coding of cores Colour of outer jacket Overall Diameter (maxi.) mm Average weight Kg/Km 1 604 1 0.21 G 24 19 x 0.12 1.38 Light blue Light blue 2.25 9.0 1 604 1 0.38 G 22 12 x 0.20 1.50 White White 2.55 11.7 1 604 1 0.60 G 20 19 x 0.20 1.70 Light blue Light blue 2.75 14.7 1 604 1 0.93 G 18 19 x 0.25 2.00 White White 3.05 19.2 1 604 1 1.34 G 16 19 x 0.30 2.30 Light blue Light blue 3.35 25.0 1 604 1 1.91 G 14 27 x 0.30 2.70 White White 3.75 31.8 1 604 1 3.18 G 12 45 x 0.30 3.50 White White 4.73 51.2 2 604 2 0.21 G 24 19 x 0.12 1.38 Light blue + Blue Light blue 3.70 5.6 2 604 2 0.38 G 22 12 x 0.20 1.50 White + Blue White 4.10 20.6 2 604 2 0.60 G 20 19 x 0.20 1.70 Light blue + Blue Light blue 4.50 27.9 2 604 2 0.93 G 18 19 x 0.25 2.00 White + blue White 5.10 37.5 2 604 2 1.34 G 16 19 x 0.30 2.30 Light blue + Blue Light blue 5.70 49.2 2 604 2 1.91 G 14 27 x 0.30 2.70 White + Blue White 6.60 62.9 2 604 2 3.18 G 12 45 x 0.30 3.50 White + Blue White 8.56 102.9 3 604 3 0.21 G 24 19 x 0.12 1.38 Light blue + Blue + Yellow Light blue 3.95 22.6 3 604 3 0.38 G 22 12 x 0.20 1.50 White + Blue + Yellow White 4.35 29.8 3 604 3 0.60 G 20 19 x 0.20 1.70 Light blue + Blue + Yellow Light blue 4.80 38.6 3 604 3 0.93 G 18 19 x 0.25 2.00 White + Blue + Yellow White 5.45 51.7 3 604 3 1.34 G 16 19 x 0.30 2.30 Light blue + Blue + Yellow Light blue 6.10 68.6 3 604 3 1.91 G 14 27 x 0.30 2.70 White + Blue + Yellow White 7.00 88.5 3 604 3 3.18 G 12 45 x 0.30 3.50 White + Blue + Yellow White 9.11 145.6 4 604 4 0.21 G 24 19 x 0.12 1.38 Light Blue + Blue + Yellow + Green Light blue 4.40 28.4 4 604 4 0.38 G 22 12 x 0.20 1.50 White + Blue+ Yellow + Green White 4.90 37.8 4 604 4 0.60 G 20 19 x 0.20 1.70 Light blue + Blue + Yellow + Green Light blue 5.40 49.1 4 604 4 0.93 G 18 19 x 0.25 2.00 White + Blue + Yellow + Green White 6.10 66.4 4 604 4 1.34 G 16 19 x 0.30 2.30 Light blue + Blue + Yellow + Green Light blue 7.00 88.6 4 604 4 1.91 G 14 27 x 0.30 2.70 White + Blue + Yellow + Green White 7.90 121.0 4 604 4 3.18 G 12 45 x 0.30 3.50 White + Blue + Yellow + Green White 10.06 186.9 Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. BASE CORE: 1604 Nb of cores FLAMEX 24 Unscreened halogen free hook-up wires, screened and jacketed hook-up wires High temperature Filotex® PRODUCTS IN THE RANGE - FLAMEX 10 - FLAMEX 15 - FLAMEX 24 To FILOTEX and NFF 63808 specifications - Operating voltage: 750 Volts - Operating temperature: (ambient temperature + rise) - unscreened hook-up wires: - 50°C up to + 150°C - screened and jacketed hook-up wires: - 30°C up to + 105°C Main characteristics: CONSTRUCTION 1- CONDUCTOR: stranded annealed tinned copper wires ■ Strictly halogen free, these wires combine the advantages of: - small size - lightweight - high chemical resistance - high mechanical properties ■ They are flame and fire retardant (to NFC 32070/C2 & C1 and IEC 332 1/2/3 specifications). 2- INSULATION: halogen free, high temperature FLAMEX 24 3- SCREEN: tinned copper braid 4 ▼ 3 ▼ 2 ▼ 1 ▼ 4- OUTER JACKET: halogen free FLAMEX UNSCREENED FLAMEX 24 HOOK-UP WIRES Average Gauge AWG Cross section mm2 FLAMEX 24 0.60 20 0.60 19 x 0.20 1.30 1.50 6.8 FLAMEX 24 0.93 18 0.93 19 x 0.25 1.55 1.75 10.2 FLAMEX 24 1.34 16 1.34 19 x 0.30 1.85 2.05 14.3 FLAMEX 24 1.82 14 1.82 37 x 0.25 2.10 2.40 19.1 FLAMEX 24 2.61 14 2.61 37 x 0.30 2.50 2.80 27.1 FLAMEX 24 4.32 12 4.32 61 x 0.30 3.00 3.30 43.4 Construction mini maxi n x Ø mm mm weight Kg/Km SCREENED AND JACKETED FLAMEX 24 HOOK-UP WIRES BASE CORE Reference FILOTEX CONDUCTOR Overall diameter Average weight Gauge AWG Cross section mm2 Construction n x Ø mm Nominal Ø core mm FLAMEX 24 0,93 BLG 18 0.93 19 x 0.25 1.65 2.50 2.90 18.9 FLAMEX 24 1.34 BLG 16 1.34 19 x 0.30 1.95 2.75 3.15 24.0 mini maxi mm Kg/Km Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Overall diameter CONDUCTOR Reference FILOTEX FLAMEX 24 Screened and jacketed, halogen free, multicore cable Filotex® PRODUCTS IN THE RANGE - FLAMEX 10 - FLAMEX 15 - FLAMEX 24 To FILOTEX and NFF 63808 specifications - Operating voltage: 750 Volts - Operating temperature: (ambient temperature + rise) - base core: – 40°C up to + 150°C - outer jacket: – 30°C up to + 105°C Main characteristics: CONSTRUCTION 1- CONDUCTOR: stranded annealed tinned copper wires ■ Strictly halogen free, these wires combine the advantages of: - small size - lighweight - high chemical resistance - high mechanical properties ■ They are flame and fire retardant (to NFC 32 070/C2 & C1 and IEC 332 1/2/3 specifications). 2- INSULATION: halogen free, high temperature FLAMEX 24 3- SCREEN: tinned copper braid 4- OUTER JACKET: halogen free FLAMEX 4 ▼ 3 ▼ ▼ 2 ▼ 1 SCREENED AND JACKETED FLAMEX 24 MULTICORE CABLE Reference FILOTEX BASE CORE CONDUCTOR Cross Gauge section Construct AWG mm2 n x Ø mm Nom. Ø core mm Overall diameter mini maxi Average weight Kg/Km mm 2 Flamex 24- 2 x 0.60 BLG 20 0.60 19 x 0.20 1.43 3.80 4.50 29.3 2 Flamex 24- 2 x 0.93 BLG 18 0.93 19 x 0.25 1.66 4.30 5.0 39.0 2 Flamex 24- 2 x 1.34 BLG 16 1.34 19 x 0.30 1.90 4.90 5.60 51.0 2 Flamex 24- 2 x 1.82 BLG 14 1.82 37 x 0.25 2.15 5.50 6.20 65.0 2 Flamex 24- 2 x 2.61 BLG 14 2.61 37 x 0.30 2.53 6.30 7.0 84.6 2 Flamex 24- 2 x 4.32 BLG 12 4.32 61 x 0.30 3.04 7.50 8.2 126.0 3 Flamex 24- 3 x 0.60 BLG 20 0.60 19 x 0.20 1.43 4.10 4.70 41.0 3 Flamex 24- 3 x 0.93 BLG 18 0.93 19 x 0.25 1.66 4.65 5.25 54.5 3 Flamex 24- 3 x 1.34 BLG 16 1.34 19 x 0.30 1.90 5.25 5.85 69.5 3 Flamex 24- 3 x 1.82 BLG 14 1.82 37 x 0.25 2.15 5.85 6.45 88.5 3 Flamex 24- 3 x 2.61 BLG 14 2.61 37 x 0.30 2.53 6.80 7.40 120.0 3 Flamex 24- 3 x 4.32 BLG 12 4.32 61 x 0.30 3.04 8.20 8.80 187.0 4 Flamex 24- 4 x 0.60 BLG 20 0.60 19 x 0.20 1.43 4.50 5.10 51.0 4 Flamex 24- 4 x 0.93 BLG 18 0.93 19 x 0.25 1.66 5.10 5.70 70.0 4 Flamex 24- 4 x 1.34 BLG 16 1.34 19 x 0.30 1.90 5.80 6.4 92.5 4 Flamex 24- 4 x 1.82 BLG 14 1.82 37 x 0.25 2.15 6.45 7.05 113 4 Flamex 24- 4 x 2.61 BLG 14 2.61 37 x 0.30 2.53 7.65 8.25 161 4 Flamex 24- 4 x 4.32 BLG 12 4.32 61 x 0.30 3.04 9.05 9.65 241 Document non contractuel. La communication ou la reproduction, l’exploitation et la communication du contenu de ces fiches sont interdites en l’absence d’autorisation préalable écrite. Filotex Nb of cores 1806 Unscreened hook-up wires Filotex® PRODUCTS IN THE RANGE -1806 - 806 To AIR 4524 and MIL-W 5086B/7A specifications These cables are approved by the Air Ministry under letters: N° 34722 STA/EQ/E2 (18-4-69) for AWG 24 N° 41763 STA/EQ/E2 (12-11-68) for AWG 22 up to AWG 12 Registered at B.N.Ae: N° 6412 420 A Operating voltage: 600 Volts RMS Operating temperature: – 50°C up to + 140°C (ambient temperature + rise) Main characteristics: ■ Flexible and lightweight serie of cables with FEP + superpolyamide 3- OUTER JACKET: superpolyamide (radial thickness: from 0,10 mm up to 0,15 mm) ■ Air 4524 specification of September 1965 - the105°/135°C category. ■ NF-L 52-120B BNAé specification of December 1971 - Lightweight cables. ■ Colour coding: to AIR 0107 A of October 1961 and note N° 348/SIB distributed under N° 5927/STT/SIB (3.05.1961). 1 2 3 ▼ 2- INSULATION: fluoropolymer (FEP) Technical requirements and control conditions: ▼ 1- CONDUCTOR: stranded tinned copper wires or stranded tinned copper alloy wires for the cross section area 0,21 mm2 insulation for use in bundles. ■ Abrasion resistance: medium ■ They are fire retardant (to NFC 32070/C1 French specification). ■ They withstand most chemical fluids except for concentrated nitric acid. ▼ CONSTRUCTION UNSCREENED HOOK-UP WIRES D.C. resist Current at 20°C rating Overall Average Construction Nominal Tensile maxi Ø strength diameter weight n x Ø mm A mm mm daN. Kg/Km Ω/Km Colour of cores 1806 - 0.21 - G 24 19 x 0.12 0.60 7 1.10 + 0,05 3.10 105.0 4 Light Blue 1806 - 0.38 - G 22 12 x 0.20 0.80 8 1.33 + 0,05 5.10 50.9 7 White 1806 - 0.60 - G 20 19 x 0.20 1.00 16 1.49 + 0,05 7.10 32.2 11 Light Blue 1806 - 0.93 - G 18 19 x 0.25 1.20 20 1.69 + 0,05 10.4 20.6 16 White 1806 - 1.34 - G 16 19 x 0.30 1.50 20 1.97 + 0,05 14.6 14.3 22 Light Blue 1806 - 1.91 - G 14 27 x 0.30 1.80 20 2.35 + 0,05 21.0 10.1 32 White 1806 - 3.18 - G 12 45 x 0.30 2.30 20 2.94 + 0,05 34.0 6.0 41 White ■ The shown current rating is valid for singles wires in air Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. CORE CONDUCTOR Reference FILOTEX 806 Screened and jacketed hook-up wires and multicore cables Filotex® PRODUCTS IN THE RANGE - 1806 - 806 To AIR 4524 and MIL-W 5086B/7A specifications These cables are approved by the Air Ministry under letters: N° 34722 STA/EQ/E2 (18-4-69) for AWG 24 N° 41763 STA/EQ/E2 (12-11-68) for AWG 22 up to AWG 12 Registered at B.N.Ae : N° 6412 420 A Operating voltage: 600 Volts RMS Operating temperature: – 50°C up to + 140°C (ambient temperature + rise) Main charateristics: ■ Screen: to MIL.C. 7078C (August1971) U.S. specification. ■ Colour coding: to Air 0107 A (October 1961) and note N° 348/SIB distributed under N° 5927/STT/SIB (3-05-1961). 806 6- OUTER JACKET: superpolyamide (radial thickness: about 0,20 mm) 5 6 ▼ 5- SCREEN: tinned copper braid (Kr ≥ 62%) 2 3 4 4- LAY UP: 1 or several 1806 cores ▼ 1806 1 ▼ 3- OUTER JACKET: superpolyamide (radial thickness: from 0,10 mm up to 0,15 mm) ▼ 2- INSULATION: fluoropolymer (FEP) Technical requirements and control conditions: ▼ 1- CONDUCTOR: stranded tinned copper wires or stranded tinned copper alloy wires for the cross section area 0,21 mm2 ▼ BASE CORE: 1806 } CONSTRUCTION ■ Flexible and lightweight serie of cables with FEP + superpolyamide insulation for use in bundles. ■ Abrasion resistance: medium ■ They are fire retardant (to NFC 32070/C1 French specification). ■ They withstand most chemical fluids except for concentrated nitric acid. SCREENED AND JACKETED HOOK-UP WIRES AND MULTICORE CABLES Number of cores 1 2 3 4 Reference FILOTEX SERIE 806 Colour of outer jacket Construction n x Ø mm Overall diameter nominal mm Colour coding of cores 806 1 0.21 G 24 19 x 0.12 1.10 Light Blue Light Blue 806 1 0.38 G 22 12 x 0.20 1.33 White 806 1 0.60 G 20 19 x 0.20 1.49 806 1 0.93 G 18 19 x 0.25 806 1 1.34 G 16 Overall Average diameter weight (maxi) Kg/Km mm 2 6.3 White 2.3 10.8 Light Blue Light Blue 2.5 13.3 1.69 White White 2.7 17.3 19 x 0.30 1.97 Light Blue Light Blue 3 22.5 806 1 1.91 G 14 27 x 0.30 2.35 White White 3.3 29.9 806 1 3.18 G 12 45 x 0.30 2.94 White White 4.2 47.0 806 2 0.21 G 24 19 x 0.12 1.10 Light Blue + Blue Light Blue 3.3 13.1 806 2 0.38 G 22 12 x 0.20 1.33 White + Blue White 3.8 19.0 806 2 0.60 G 20 19 x 0.20 1.49 Light Blue + Blue Light BLue 4.1 24.0 806 2 0.93 G 18 19 x 0.25 1.69 White + Blue White 4.5 33.7 806 2 1.34 G 16 19 x 0.30 1.97 Light Blue + Blue Light Blue 5.2 44.1 806 2 1.91 G 14 27 x 0.30 2.35 White + Blue White 5.9 59.0 806 2 3.18 G 12 45 x 0.30 2.94 White + Blue White 7.7 94.0 806 3 0.21 G 24 19 x 0.12 1.10 3.5 17.5 806 3 0.38 G 22 12 x 0.20 1.33 4 25.9 806 3 0.60 G 20 19 x 0.20 1.49 4.4 35.0 806 3 0.93 G 18 19 x 0.25 1.69 4.8 46.8 806 3 1.34 G 16 19 x 0.30 1.97 5.5 61.9 806 3 1.91 G 14 27 x 0.30 2.35 White + Blue + Yellow White 6.3 83.6 806 3 3.18 G 12 45 x 0.30 2.94 White + Blue + Yellow White 8,2 134 806 4 0.21 G 24 19 x 0.12 1.10 Light Blue + Blue + Yellow + Green Light Blue 3.7 21.6 806 4 0.38 G 22 12 x 0.20 1.33 White + Blue + Yellow + Green White 4.4 34.4 806 4 0.60 G 20 19 x 0.20 1.49 White + Blue + Yellow + Green Light Blue 4.8 43.9 806 4 0.93 G 18 19 x 0.25 2.69 White + Blue + Yellow + Green White 5.3 59.3 806 4 1.34 G 16 19 x 0.30 2.97 Light Blue + Blue + Yellow + Green Light Blue 6 79.0 806 4 1.91 G 14 27 x 0.30 2.35 White + Blue + Yellow + Green White 6.9 107.4 806 4 3.18 G 12 45 x 0.30 2.94 White + Blue + Yellow + Green White 9.1 172.5 Light Blue + Blue + Yellow Light Blue White + Blue + Yellow White Light Blue + Blue + Yellow Light Blue White + Blue + Yellow White Light Blue + Blue + Yellow Light Blue Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. BASE CORE: 1806 KU Unscreened hook up wires pairs and triples Filotex® PRODUCTS IN THE RANGE - KU To NFC 93 524 French specification - Operating voltage: 600 Volts - Operating temperature: – 55°C up to + 150°C (ambient temperature + rise) Main characteristics: ■ Applications: internal wiring in electronic equipment. ■ They are flame and fire retardant (to NFC 32070/C2 and C1 French specification). CONSTRUCTION BASE CORE : KU 01 1- CONDUCTOR: stranded annealed tinned copper wires 2- INSULATION: ethylene and tetrafluorethylene copolymer (E.T.F.E) KU 03 and KU 04 3 { 2 ▼ 1 ▼ KU 01 ▼ 3- LAY UP: 2 or 3 base cores UNSCREENED HOOK-UP WIRES CONDUCTOR Overall diameter maxi. mini. mm Average weight and FILOTEX Gauge AWG Cross section mm2 Construction n x Ø mm KU 01-30 30 0.05 7 x 0.10 0.58 0.68 0.95 KU 01-28 28 0.09 7 x 0.13 0.64 0.74 1.50 KU 01-26 26 0.15 19 x 0.10 0.76 0.86 2.00 KU 01-24 24 0.25 19 x 0.13 0.86 0.96 3.60 KU 01-22 22 0.38 19 x 0.16 1.05 1.15 4.60 KU 01-20 20 0.60 19 x 0.20 1.47 1.57 7.65 KU 01-18 18 0.93 19 x 0.25 1.75 1.85 11.35 KU 01-16 16 1.34 19 x 0.30 1.93 2.07 15.50 KU 01-14 14 1.82 37 x 0.25 2.26 2.46 21.40 KU 01-12 12 3.00 37 x 0.32 2.79 2.99 33.80 Kg/Km UNSCREENED PAIRS AND TRIPLES Reference Nb NFC 93 524 of and cond. FILOTEX BASE CORE Overall Diameter CONDUCTOR Type Nom. Ø Cross Gauge Construction core section AWG mm2 n x Ø mm mm mini. maxi. mm Average weight Kg/Km Colour Coding of cores 2 2 2 2 2 2 2 2 2 2 KU 03 - 30 KU 03 - 28 KU 03 - 26 KU 03 - 24 KU 03 - 22 KU 03 - 20 KU 03 - 18 KU 03 - 16 KU 03 - 14 KU 03 - 12 KU 01 - 30 KU 01 - 28 KU 01 - 26 KU 01 - 24 KU 01 - 22 KU 01 - 20 KU 01 - 18 KU 01 - 16 KU 01 - 14 KU 01 - 12 30 28 26 24 22 20 18 16 14 12 0.05 0.09 0.15 0.25 0.38 0.60 0.93 1.34 1.82 3.00 7 x 0.10 7 x 0.13 19 x 0.10 19 x 0.13 19 x 0.16 19 x 0.20 19 X 0.25 19 X 0.30 37 X 0.25 37 X 0.32 0.63 0.69 0.81 0.91 1.10 1.52 1.80 2.00 2.36 2.89 1.16 1.28 1.52 1.72 2.10 2.94 3.50 3.86 4.52 5.58 1.36 1.48 1.72 1.92 2.30 3.14 3.70 4.14 4.92 5.98 2.0 3.1 4.1 7.4 9.5 16.0 23.8 32.6 44.9 71.0 White Blue 3 3 3 3 3 3 3 3 3 3 KU 04 - 30 KU 04 - 28 KU 04 - 26 KU 04 - 24 KU 04 - 22 KU 04 - 20 KU 04 - 18 KU 04 - 16 KU 04 - 14 KU 04 - 12 KU 01 - 30 KU 01 - 28 KU 01 - 26 KU 01 - 24 KU 01 - 22 KU 01 - 20 KU 01 - 18 KU 01 - 16 KU 01 - 14 KU 01 - 12 30 28 26 24 22 20 18 16 14 12 0.05 0.09 0.15 0.25 0.38 0.60 0.93 1.34 1.82 3.00 7 x 0.10 7 x 0.13 19 x 0.10 19 x 0.13 19 x 0.16 19 x 0.20 19 X 0.25 19 X 0.30 37 X 0.25 37 X 0.32 0.63 0.69 0.81 0.91 1.10 1.52 1.80 2.00 2.36 2.89 1.25 1.38 1.63 1.85 2.26 3.16 3.76 4.15 4.86 6.00 1.46 1.58 1.85 2.06 2.47 3.38 3.98 4.45 5.29 6.43 3.0 4.7 6.1 11.4 14.1 24.1 35.8 48.8 67.4 106.5 White Blue Orange Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Reference NFC 93 524 KU Screened and jacketed hook-up wires, pairs and triples Filotex® PRODUCTS IN THE RANGE - KU To NFC 93 524 French specification - Operating voltage: 600 Volts - Operating temperature: – 55°C up to + 150°C (ambient temperature + rise) Main Characteristics: ■ Applications: internal wiring in electronic equipment. ■ They are flame and fire retardant (to NFC 32 070/C2 and C1 French specification) CONSTRUCTION BASE CORE: KU 01 1- CONDUCTOR: stranded annealed tinned copper wires 2- INSULATION: ethylene and tetrafluorethylene copolymer (E.T.F.E) 3- SCREEN: tinned copper braid 4 ▼ 3 ▼ } 1 2 ▼ KU 01 ▼ 4- OUTER JACKET: ethylene and tetrafluorethylene copolymer (E.T.F.E.) SCREENED AND JACKETED HOOK-UP WIRES 1 1 1 1 1 1 1 1 1 1 KU 02 - 30 KU 02 - 28 KU 02 - 26 KU 02 - 24 KU 02 - 22 KU 02 - 20 KU 02 - 18 KU 02 - 16 KU 02 - 14 KU 02 - 12 BASE CORE CONDUCTOR Type KU 01 - 30 KU 01 - 28 KU 01 - 26 KU 01 - 24 KU 01 - 22 KU 01 - 20 KU 01 - 18 KU 01 - 16 KU 01 - 14 KU 01 - 12 Braid Nominal Ø Gauge Cross Construction core section AWG mm2 n x Ø mm mm 30 28 26 24 22 20 18 16 14 12 0.05 0.09 0.15 0.25 0.38 0.60 0.93 1.34 1.82 3.00 7 x 0.10 7 x 0.13 19 x 0.10 19 x 0.13 19 x 0.16 19 x 0.20 19 X 0.25 19 X 0.30 37 X 0.25 37 X 0.32 0.63 0.69 0.81 0.91 1.10 1.52 1.80 2.00 2.36 2.89 Overall diameter Ø Strands mm mini. 0.10 0.10 0.10 0.10 0.10 0.10 0.12 0.12 0.12 0.12 1.23 1.29 1.41 1.61 1.86 2.28 2.61 2.81 3.17 3.70 maxi. Average weight Kg/Km mm 1.43 1.49 1.61 1.81 2.06 2.48 2.91 3.11 3.47 4.0 4.00 5.36 5.50 8.80 10.0 14.80 21.40 29.70 34.50 48.80 SCREENED AND JACKETED PAIRS AND TRIPLES Reference Nb NFC 93 524 of and cores FILOTEX BASE CORE CONDUCTOR Type Braid Nominal Ø Gauge Cross Construction core section AWG mm2 n x Ø mm mm Overall diameter Ø Strands mm mini. maxi. Average weight Kg/Km mm Colour coding of cores 2 2 2 2 2 2 2 2 2 2 KU 05 - 30 KU 05 - 28 KU 05 - 26 KU 05 - 24 KU 05 - 22 KU 05 - 20 KU 05 - 18 KU 05 - 16 KU 05 - 14 KU 05 - 12 KU 01 - 30 KU 01 - 28 KU 01 - 26 KU 01 - 24 KU 01 - 22 KU 01 - 20 KU 01 - 18 KU 01 - 16 KU 01 - 14 KU 01 - 12 30 28 26 24 22 20 18 16 14 12 0.05 0.09 0.15 0.25 0.38 0.60 0.93 1.34 1.82 3.00 7 x 0.10 7 x 0.13 19 x 0.10 19 x 0.13 19 x 0.16 19 x 0.20 19 x 0.25 19 x 0.30 37 x 0.25 37 x 0.32 0.63 0.69 0.81 0.91 1.10 1.52 1.80 2.00 2.36 2.89 0.10 0.10 0.10 0.12 0.12 0.12 0.12 0.12 0.12 0.12 1.98 2.10 2.32 2.62 2.99 3.81 4.36 4.76 5.52 6.53 2.22 2.34 2.62 2.91 3.30 4.13 4.72 5.12 5.92 7.03 8.50 11.70 12.10 18.80 21.10 29.20 39.30 49.50 65.70 96.70 White Blue 3 3 3 3 3 3 3 3 3 3 KU 06 - 30 KU 06 - 28 KU 06 - 26 KU 06 - 24 KU 06 - 22 KU 06 - 20 KU 06 - 18 KU 06 - 16 KU 06 - 14 KU 06 - 12 KU 01 - 30 KU 01 - 28 KU 01 - 26 KU 01 - 24 KU 01 - 22 KU 01 - 20 KU 01 - 18 KU 01 - 16 KU 01 - 14 KU 01 - 12 30 28 26 24 22 20 18 16 14 12 0.05 0.09 0.15 0.25 0.38 0.60 0.93 1.34 1.82 3.00 7 x 0.10 7 x 0.13 19 x 0.10 19 x 0.13 19 x 0.16 19 x 0.20 19 x 0.25 19 x 0.30 37 x 0.25 37 x 0.32 0.63 0.69 0.81 0.91 1.10 1.52 1.80 2.00 2.36 2.89 0.10 0.10 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 2.19 2.31 2.54 2.74 3.15 4.06 4.66 5.09 5.87 7.01 2.43 2.50 2.82 3.05 3.46 4.38 4.98 5.40 6.31 7.47 11.40 14.60 15.70 23.80 26.40 39.80 53.70 68.70 92.80 137.40 White Blue Orange Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Nb Reference of NFC 93 524 and cores FILOTEX M 22759/16 Unscreened hook-up wires High temperature Lightweight serie Filotex® PRODUCTS IN THE RANGE - M 22759/16 To MIL W 22759/16 specification - Operating voltage: 600 Volts - Operating temperature: – 55°C up to + 150°C (ambient temperature + rise) - M 22759/18 Main characteristics: ■ Applications: internal wiring in electronic equipment. ■ They are fire retardant (to NFC 32070/C1 French specification). CONSTRUCTION 1- CONDUCTOR: stranded tinned copper wires 2 ▼ 1 ▼ 2- INSULATION: ethylene and tetrafluorethylene copolymer (E.T.F.E.) UNSCREENED HOOK-UP WIRES LIGHTWEIGHT SERIE M22759/16 CONDUCTOR Gauge AWG Cross section mm2 Construction n x Ø mm 19 x 0.203 1.52 + 0.05 7.9 19 x 0.254 1.80 + 0.05 11.7 19 x 0.287 2.01 + 0.05 14.8 19 x 0.361 2.36 + 0.05 22.1 37 x 0.320 2.90 + 0.76 33.6 37 x 0.404 3.53 + 0.76 52.2 19 x 7 x 0.287 5.06 + 0.76 94.4 19 x 7 x 0.361 6.35 + 0.76 148.7 19 x 7 x 0.455 7.92 + 0.10 233 19 x 35 x 0.254 9.85 + 0.10 364 19 x 0.127 M22759/16-22 22 0.38 M22759/16-18 M22759/16-16 M22759/16-14 M22759/16-12 M22759/16-10 M22759/16-8 M22759/16-6 M22759/16-4 M22759/16-2 18 16 14 12 10 8 6 4 2 0.96 1.23 1.94 2.98 4.74 8.6 13.6 21.6 33.7 Kg/Km 19 x 0.16 0.24 0.61 mm 3.8 24 20 Average weight 1.14 + 0.05 1.32 + 0.05 M22759/16-24 M22759/16-20 Overall diameter 5.4 Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Reference MIL W and FILOTEX M 22759/18 Unscreened hook-up wires High temperature Extra-lightweight serie Filotex® PRODUCTS IN THE RANGE - M 22759/16 To MIL W 22759/18 specification - Operating voltage: 600 Volts - Operating temperature: – 55°C up to + 150°C (ambient temperature + rise) - M 22759/18 Main characteristics: ■ Applications: internal wiring in electronic equipment. ■ They are fire retardant (to NFC 32070/C1 French specification). CONSTRUCTION 1- CONDUCTOR: stranded tinned copper wires 2 ▼ 1 ▼ 2- INSULATION: ethylene and tetrafluorethylene copolymer (E.T.F.E) UNSCREENED HOOK-UP WIRES - EXTRA-LIGHTWEIGHT SERIE - M 22759/18 CONDUCTOR Gauge AWG Cross section mm2 Construction n x Ø mm 19 x 0.16 1.09 + 0.05 7.9 19 x 0.203 1.30 + 0.05 11.7 19 x 0.254 1.55 + 0.05 14.8 19 x 0.287 1.78 + 0.05 22.1 19 x 0.361 2.16 + 0.05 33.6 37 x 0.32 2.72 + 0.076 52.2 37 x 0.404 3.40 + 0.076 94.4 19 x 0.102 M22759/18-24 24 0.24 M22759/18-20 M22759/18-18 M22759/18-16 M22759/18-14 M22759/18-12 M22759/18-10 20 18 16 14 12 10 0.61 0.96 1.23 1.94 2.98 4.74 Kg/Km 19 x 0.127 0.155 0.38 mm 2.2 26 22 Average weight 0.81 + 0.05 0.91 + 0.05 M22759/18-26 M22759/18-22 Overall diameter 3.1 Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Reference MIL W and FILOTEX KZ 04 Unscreened hook-up wires High temperature Filotex® PRODUCTS IN THE RANGE - KZ 04 To NF C 93-523 French specification - Operating voltage: 250 Volts - Operating temperature: – 55°C up to + 200°C (ambient temperature + rise) - KZ 05 - KZ 06 CONSTRUCTION Main characteristics: ■ Applications: - Internal wiring in electronic equipment. - Aircrafts and satellites. ■ Operating frequency: up to 2 000 Hz. ■ Excellent chemical resistance. ■ They are fire retardant (to NFC 32070/C1 French specification). 1- CONDUCTOR: stranded silvered copper wires 2 ▼ 1 ▼ 2- INSULATION: extruded polytetrafluorethylene (P.T.F.E.) (radial thickness according to the gauges: from 0,15 mm up to 0,18 mm) UNSCREENED HOOK-UP WIRES Reference FILOTEX Overall D.C. resist. diameter at 20°C (Ohm/Km) mini. maxi. Maximum weight Gauge AWG Cross section mm2 Construction (n x Ø mm) Nom. Ø mm KZ 04 — 01 32 0,035 7 x 0.08 0.24 546 0.48 0.58 0.95 KZ 04 — 02 30 0,055 7 x 0.10 0.30 349 0.56 0.66 1.3 KZ 04 — 03 28 0,093 7 x 0.13 0.39 201 0.63 0.73 1.75 KZ 04 — 04 26 0,14 7 x 0.16 0.48 132 0.74 0.84 2.4 KZ 04 — 05 24 0,22 7 x 0.20 0.60 86 0.86 0.96 3.4 KZ 04 — 06 22 0,34 7 x 0.25 0.75 54.4 1.01 1.11 5.0 KZ 04 — 07 20 0,60 19 x 0.20 1.00 31.3 1.30 1.40 8.25 mm maxi. Kg/Km Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. CONDUCTOR KZ 05 Unscreened hook-up wires High temperature Filotex® PRODUCTS IN THE RANGE - KZ 04 To NF C 93-523 French specification - Operating voltage: 600 Volts - Operating temperature: – 55°C up to + 200°C (ambient temperature + rise) - KZ 05 - KZ 06 CONSTRUCTION Main characteristics: ■ Applications: - Internal wiring in electronic equipment. - Aircrafts and satellites. ■ Operating frequency: up to 2 000 Hz. ■ Excellent chemical resistance. ■ They are fire retardant (to NFC 32070/C1 French specification). 1- CONDUCTOR: stranded silvered copper wires 2 ▼ 1 ▼ 2- INSULATION: extruded polytetrafluorethylene (P.T.F.E.) (radial thickness according to the gauges: from 0,25 mm up to 0,30 mm) UNSCREENED HOOK-UP WIRES Gauge AWG Cross section mm2 Construction n x Ø mm Overall D.C. resist. diameter at 20°C Nom. (Ohms/Km) Ø mini. maxi. mm mm maxi. Maximum weight Kg / Km KZ 05 — 01 32 0,035 7 x 0.08 0.24 546 0.63 0.84 1.65 KZ 05 — 02 30 0,055 7 x 0.10 0.30 349 0.71 0.91 2.1 KZ 05 — 03 28 0,093 7 x 0.13 0.39 201 0.79 1.00 2.6 KZ 05 — 04 26 0,14 7 x 0.16 0.48 132 0.89 1.10 3.4 KZ 05 — 05 24 0,22 7 x 0.20 0.60 86 1.04 1.22 4.5 KZ 05 — 06 22 0,34 7 x 0.25 0.75 54.4 1.17 1.37 6.2 KZ 05 — 07 20 0,60 19 x 0.20 1.00 31.3 1.42 1.62 9.5 KZ 05 — 08 18 0.93 19 x 0.25 1.25 20.5 1.67 1.92 14.1 KZ 05 — 09 16 1.34 19 x 0.30 1.50 13.9 1.92 2.27 20.0 KZ 05 — 10 14 1.91 27 x 0.30 1.85 10.0 2.30 2.66 27.0 KZ 05 — 11 12 3.18 45 x 0.30 2.45 6.0 2.89 3.24 42.5 Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. CONDUCTOR Reference FILOTEX KZ 06 Unscreened hook-up wires High temperature Filotex® PRODUCTS IN THE RANGE - KZ 04 To NF C 93-523 French specification - Operating voltage: 1 000 Volts - Operating temperature: – 55°C up to + 200°C (ambient temperature + rise) - KZ 05 - KZ 06 CONSTRUCTION Main characteristics: ■ Applications: - Internal wiring in electronic equipment. - Aircrafts and satellites. ■ Operating frequency: up to 2 000 Hz. ■ Excellent chemical resistance. ■ They are fire retardant (to NFC 32070/C1 French specification). 1- CONDUCTOR: stranded silvered copper wires 2 ▼ 1 ▼ 2- INSULATION: extruded polytetrafluorethylene (P.T.F.E.) (radial thickness according to the gauges: from 0,37 mm up to 0,45 mm) UNSCREENED HOOK-UP WIRES Overall D.C. resist. diameter at 20°C Nom. (Ohms/Km) mini. maxi. Ø mm maxi. mm Maximum weight Gauge AWG Cross section mm2 Construction n x Ø mm KZ 06 — 01 32 0,035 7 x 0.08 0.24 546 0.88 1.09 2.6 KZ 06 — 02 30 0,055 7 x 0.10 0.30 349 0.95 1.16 3.0 KZ 06 — 03 28 0,093 7 x 0.13 0.39 201 1.04 1.24 3.7 KZ 06 — 04 26 0,14 7 x 0.16 0.48 132 1.14 1.34 4.6 KZ 06 — 05 24 0,22 7 x 0.20 0.60 86 1.27 1.47 5.75 KZ 06 — 06 22 0,34 7 x 0.25 0.75 54.4 1.42 1.63 7.7 KZ 06 — 07 20 0,60 19 x 0.20 1.00 31.3 1.66 1.86 11.0 KZ 06 — 08 18 0.93 19 x 0.25 1.25 20.5 1.92 2.17 16.0 KZ 06 — 09 16 1.34 19 x 0.30 1.50 13.9 2.10 2.41 21.1 KZ 06 — 10 14 1.91 27 x 0.30 1.85 10.0 2.51 2.92 30.0 KZ 06 — 11 12 3.18 45 x 0.30 2.45 6.0 3.14 3.55 47.5 Kg / Km Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. CONDUCTOR Reference FILOTEX KZ 55 Screened and jacketed hook-up wires High temperature Filotex® PRODUCTS IN THE RANGE - KZ 55 To NF C 93-523 French specification - Operating voltage: 250 Volts - Operating temperature: – 55°C up to + 200°C (ambient temperature + rise) - KZ 57 - KZ 59 CONSTRUCTION Main characteristics: ■ Applications: - Internal wiring in electronic equipment. - Aircrafts and satellites. ■ Operating frequency: up to 2 000 Hz. ■ Excellent chemical resistance. ■ They are fire retardant (to NFC 32070/C1 French specification). BASE CORE: KZ 04 1- CONDUCTOR: stranded silvered copper wires 4 ▼ 3 2 ▼ 1 ▼ KZ 04 4- OUTER JACKET: fluoropolymer (FEP) (radial thickness: 0,30 mm nominal) } 3- SCREEN: polyimide tape and silvered copper braid ▼ 2- INSULATION: extruded polytetrafluorethylene (P.T.F.E.) (radial thickness according to the gauges: from 0,15 mm up to 0,18 mm) SCREENED AND JACKETED HOOK-UP WIRES Type KZ 55-04 KZ 04-04 26 0.14 7 x 0.16 0.48 132 0.10 1.85 2.05 8.11 KZ 55-05 KZ 04-05 24 0.22 7 x 0.20 0.60 86 0.10 1.97 2.17 9.66 KZ 55-06 KZ 04-06 22 0.34 7 x 0.25 0.75 54.4 0.10 2.12 2.32 11.90 KZ 55-07 KZ 04-07 20 0.60 19 x 0.20 1.00 31.3 0.10 2.40 2.60 16.50 Colour coding: white core - White outer jacket Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Overall DC Braid diameter resist. Average CONDUCTOR at Nom. mini. maxi. weight Ø 20°C Cross Gauge Construction Nominal Ω/Km strands section Ø AWG n x Ø mm mm Kg/Km mm maxi. mm mm2 BASE CORE Reference NFC 93 523 and FILOTEX KZ 57 Screened and jacketed hook-up wires High temperature Filotex® PRODUCTS IN THE RANGE - KZ 55 - KZ 57 To NF C 93-523 French specification - Operating voltage: 600 volts - Operating temperature: – 55°C up to + 200°C (ambient temperature + rise) - KZ 59 Main characteristics: CONSTRUCTION BASE CORE : KZ05 ■ Applications: - Internal wiring in electronic equipment. - Aircrafts and satellites. ■ Operating frequency: up to 2 000 Hz. ■ Excellent chemical resistance. ■ They are fire retardant (to NFC 32070/C1 French specification). 1- CONDUCTOR: stranded silvered copper wires 2- INSULATION: extruded polytetrafluorethylene (P.T.F.E.) (radial thickness according to the gauges: from 0,28 mm up to 0,30 mm) 4 ▼ 3 2 ▼ 1 ▼ KZ 05 } 4- OUTER JACKET: fluoropolymer (FEP) (radial thickness: 0,30 mm nominal) ▼ 3- SCREEN: silvered copper braid SCREENED AND JACKETED HOOK-UP WIRES Type Overall diameter mini. maxi. mm Average weight Kg/Km KZ 57-01 KZ 05-01 32 0.035 7 x 0.08 0.24 546 0.10 1.72 1.97 6.72 KZ 57-02 KZ 05-02 30 0.055 7 x 0.10 0.30 349 0.10 1.79 2.04 7.49 KZ 57-03 KZ 05-03 28 0.093 7 x 0.13 0.39 201 0.10 1.88 2.13 8.39 KZ 57-04 KZ 05-04 26 0.14 7 x 0.16 0.48 132 0.10 1.98 2.23 9.63 KZ 57-05 KZ 05-05 24 0.22 7 x 0.20 0.60 86 0.10 2.11 2.36 11.30 KZ 57-06 KZ 05-06 22 0.34 7 x 0.25 0.75 54.4 0.10 2.25 2.50 13.60 KZ 57-07 KZ 05-07 20 0.60 19 x 0.20 1.00 31.3 0.13 2.65 2.90 20.00 KZ 57-08 KZ 05-08 18 0.93 19 x 0.25 1.25 20.5 0.13 2.93 3.18 26.10 KZ 57-09 KZ 05-09 16 1.34 19 x 0.30 1.50 13.9 0.13 3.23 3.53 33.50 KZ 57-10 KZ 05-10 14 1.91 27 x 0.30 1.85 10.0 0.13 3.61 3.91 42.60 KZ 57-11 KZ 05-11 12 3.18 45 x 0.30 2.45 6.0 0.13 4.19 4.49 61.10 Colour coding: white core - White outer jacket Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Braid DC resist. CONDUCTOR Nom. at 20°C Ø Cross Gauge Construction Nom. Ω/Km strands Ø section AWG n x Ø mm mm Maxi. mm mm2 BASE CORE Reference NFC 93 523 and FILOTEX KZ 59 Screened and jacketed hook-up wires High temperature Filotex® PRODUCTS IN THE RANGE - KZ 55 To NF C 93-523 French specification - Operating voltage: 1 000 Volts - Operating temperature: – 55°C up to + 200°C (ambient temperature + rise) - KZ 57 - KZ 59 CONSTRUCTION Main characteristics: ■ Applications: - Internal wiring in electronic equipment. - Aircrafts and satellites. ■ Operating frequency: up to 2 000 Hz. ■ Excellent chemical resistance. ■ They are fire retardant (to NFC 32070/C1 French specification). BASE CORE: KZ 06 1- CONDUCTOR: stranded silvered copper wires 2- INSULATION: extruded polytetrafluorethylene (P.T.F.E.) (radial thickness according to the gauges: from 0,37 mm up to 0,45 mm) 4 ▼ 3 2 ▼ 1 ▼ KZ 06 } 4- OUTER JACKET: fluoropolymer (FEP) (radial thickness: 0,30 mm nominal) ▼ 3- SCREEN: silvered copper braid SCREENED AND JACKETED HOOK-UP WIRES Type Overall diameter mini. Average maxi. weight mm Kg/Km KZ 59-01 KZ 06-01 32 0.035 7 x 0.08 0.24 546 0.10 1.97 2.22 8.79 KZ 59-02 KZ 06-02 30 0.055 7 x 0.10 0.30 349 0.10 2.03 2.28 9.45 KZ 59-03 KZ 06-03 28 0.093 7 x 0.13 0.39 201 0.10 2.12 2.37 10.6 KZ 59-04 KZ 06-04 26 0.14 7 x 0.16 0.48 132 0.10 2.22 2.47 11.9 KZ 59-05 KZ 06-05 24 0.22 7 x 0.20 0.60 86 0.10 2.35 2.60 13.6 KZ 59-06 KZ 06-06 22 0.34 7 x 0.25 0.75 54.4 0.13 2.65 2.90 18.2 KZ 59-07 KZ 06-07 20 0.60 19 x 0.20 1.00 31.3 0.13 2.89 3.14 22.7 KZ 59-08 KZ 06-08 18 0.93 19 x 0.25 1.25 20.5 0.13 3.18 3.43 29.2 KZ 59-09 KZ 06-09 16 1.34 19 x 0.30 1.50 13.9 0.13 3.38 3.68 35.4 KZ 59-10 KZ 06-10 14 1.91 27 x 0.30 1.85 10.0 0.13 3.84 4.19 46.8 KZ 59-11 KZ 06-11 12 3.18 45 x 0.30 2.45 6.0 0.13 4.65 5.00 70.4 Colour coding: white core - White outer jacket Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Braid DC resist. Nom. CONDUCTOR Ø at 20°C Gauge Cross Construction Nominal Ω/Km strands Ø AWG section mm Maxi. mm mm2 n x Ø mm BASE CORE Reference NFC 93 523 and FILOTEX KZ 67 Screened and jacketed pairs High temperature Filotex® PRODUCTS IN THE RANGE - KZ 67 To NF C 93-523 French specification - Operating voltage: 250 Volts - Operating temperature: – 55°C up to + 200°C (ambient temperature + rise) - KZ 69 - KZ 71 CONSTRUCTION Main characteristics: ■ Applications: - Internal wiring in electronic equipment. - Aircrafts and satellites. ■ Operating temperature: up to 2 000 Hz. ■ Excellent chemical resistance. ■ They are fire retardant (to NFC 32070/C1 French specification). BASE CORE: KZ 04 1- CONDUCTOR: stranded silvered copper wires 4 ▼ 3 1 2 ▼ 4- OUTER JACKET: fluoropolymer (FEP) (radial thickness: 0,30 mm nominal) ▼ KZ 04 } 3- SCREEN: polyimide tape and silvered copper braid ▼ 2- INSULATION: extruded polytetrafluorethylene (P.T.F.E.) (radial thickness according to the gauges: from 0,15 mm up to 0,18 mm) SCREENED AND JACKETED PAIRS Type KZ 67-01 KZ 04-01 32 0.035 7 x 0.08 0.24 573 0.10 2.11 2.36 8.03 KZ 67-02 KZ 04-02 30 0.055 7 x 0.10 0.30 366 0.10 2.27 2.52 9.35 KZ 67-03 KZ 04-03 28 0.093 7 x 0.13 0.39 211 0.10 2.41 2.62 10.8 KZ 67-04 KZ 04-04 26 0.14 7 x 0.16 0.48 138 0.10 2.63 2.88 13.0 KZ 67-05 KZ 04-05 24 0.22 7 x 0.20 0.60 90 0.13 3.02 3.27 17.9 KZ 67-06 KZ 04-06 22 0.34 7 x 0.25 0.75 57 0.13 3.32 3.57 22.5 KZ 67-07 KZ 04-07 20 0.60 19 x 0.20 1.00 33 0.13 3.90 4.15 31.7 Colour coding: - cores: white + light blue - outer jacket: white Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Braid Overall diameter DC Average resist. Nom. CONDUCTOR mini. maxi. weight at 20°C Ø Cross Nom. Gauge Construction Ω/Km strands Ø section AWG n x Ø mm mm Kg/Km mm 2 mm Maxi. mm BASE CORE Reference NFC 93 523 and FILOTEX KZ 69 Screened and jacketed pairs High temperature Filotex® PRODUCTS IN THE RANGE - KZ 67 To NF C 93-523 French specification - Operating voltage: 600 Volts - Operating temperature: – 55°C up to + 200°C (ambient temperature + rise) - KZ 69 - KZ 71 CONSTRUCTION Main characteristics: ■ Applications: - Internal wiring in electronic equipment. - Aircrafts and satellites. ■ Operating frequency: up to 2 000 Hz. ■ Excellent chemical resistance. ■ They are fire retardant (to NFC 32070/C1 French specification). BASE CORE: KZ 05 1- CONDUCTOR: stranded silvered copper wires 4 ▼ 3 ▼ 1 2 ▼ KZ 05 4- OUTER JACKET: fluoropolymer (FEP) (radial thickness: 0,30 mm nominal) } 3- SCREEN: silvered copper braid ▼ 2- INSULATION: extruded polytetrafluorethylene (P.T.F.E.) (radial thickness according to the gauges: from 0,25 mm up to 0,30 mm) SCREENED AND JACKETED PAIRS CONDUCTOR Type Cross Construction Gauge section n x Ø mm AWG mm2 Braid DC Overall diameter resist. Nom. Average at 20°C Ø mini. maxi. weight Nom. Ω/Km strands Ø Kg/Km mm mm maxi. mm KZ 69-01 KZ 05-01 32 0.035 7 x 0.08 0.24 573 0.10 2.46 2.71 10.6 KZ 69-02 KZ 05-02 30 0.055 7 x 0.10 0.30 366 0.10 2.60 2.85 12.0 KZ 69-03 KZ 05-03 28 0.093 7 x 0.13 0.39 211 0.10 2.78 3.03 13.7 KZ 69-04 KZ 05-04 26 0.14 7 x 0.16 0.48 138 0.13 3.13 3.38 18.1 KZ 69-05 KZ 05-05 24 0.22 7 x 0.20 0.60 90 0.13 3.39 3.64 21.5 KZ 69-06 KZ 05-06 22 0.34 7 x 0.25 0.75 57 0.13 3.67 3.92 26.2 KZ 69-07 KZ 05-07 20 0.60 19 x 0.20 1.00 33 0.13 4.17 4.42 35.1 KZ 69-08 KZ 05-08 18 0.93 19 x 0.25 1.25 21.5 0.13 4.73 5.08 46.9 KZ 69-09 KZ 05-09 16 1.34 19 x 0.30 1.50 14.6 0.13 5.51 5.86 64.4 KZ 69-10 KZ 05-10 14 1.91 27 x 0.30 1.85 10.5 0.13 6.27 6.62 82.4 KZ 69-11 KZ 05-11 12 3.18 45 x 0.30 2.45 6.3 0.13 7.43 7.78 120.0 Colour coding: - cores: white + light blue - outer jacket: white Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. BASE CORE Reference NFC 93 523 and FILOTEX KZ 71 Screened and jacketed pairs High temperature Filotex® PRODUCTS IN THE RANGE - KZ 67 To NF C 93-523 French specification - Operating voltage: 1 000 Volts - Operating temperature: – 55°C up to + 200°C (ambient temperature + rise) - KZ 69 - KZ 71 CONSTRUCTION Main characteristics: ■ Applications: - Internal wiring in electronic equipment. - Aircrafts and satellites. ■ Operating frequency: up to 2 000 Hz. ■ Excellent chemical resistance. ■ They are fire retardant (to NFC 32070/C1 French specification). BASE CORE: KZ 06 1- CONDUCTOR: stranded silvered copper wires 4 ▼ 3 1 2 ▼ 4- OUTER JACKET: fluoropolymer (FEP) (radial thickness: 0,30 mm nominal) ▼ KZ 06 } 3- SCREEN: silvered copper braid ▼ 2- INSULATION: extruded polytetrafluorethylene (P.T.F.E.) (radial thickness according to the gauges: from 0,37 mm up to 0,45 mm) SCREENED AND JACKETED PAIRS CONDUCTOR Type Cross Gauge Construction section AWG n x Ø mm mm2 Braid DC Overall diameter resist. Nom. Average at 20°C Ø maxi. weight mini. Nom. Ω/Km strands Ø Maxi. Kg/Km mm mm mm KZ 71-01 KZ 06-01 32 0.035 7 x 0.08 0.24 0.13 3.11 3.36 16.4 0.30 573 366 KZ 71-02 KZ 06-02 30 0.055 7 x 0.10 0.13 3.23 3.48 17.7 0.13 3.41 3.66 19.9 KZ 71-03 KZ 06-03 28 0.093 7 x 0.13 0.39 211 KZ 71-04 KZ 06-04 26 0.14 7 x 0.16 0.48 138 0.13 3.61 3.86 22.6 KZ 71-05 KZ 06-05 24 0.22 7 x 0.20 0.60 90 0.13 3.87 4.12 26.1 KZ 71-06 KZ 06-06 22 0.34 7 x 0.25 0.75 57 0.13 4.17 4.42 31.4 0.13 4.65 4.90 40.2 KZ 71-07 KZ 06-07 20 0.60 19 x 0.20 1.00 33 KZ 71-08 KZ 06-08 18 0.93 19 x 0.25 1.25 21.5 0.13 5.39 5.64 55.6 KZ 71-09 KZ 06-09 16 1.34 19 x 0.30 1.50 14.6 0.13 5.81 6.16 68.1 KZ 71-10 KZ 06-10 14 1.91 27 x 0.30 1.85 10.5 0.13 6.73 7.08 90.7 2.45 6.3 0.13 7.99 8.34 133 KZ 71-11 KZ 06-11 Colour coding: - cores: white + light blue - outer jacket: white 12 3.18 45 x 0.30 Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. BASE CORE Reference NFC 93 523 and FILOTEX KZ 79 Screened and jacketed triples High temperature Filotex® PRODUCTS IN THE RANGE - KZ 79 To NF C 93-523 French specification - Operating voltage: 250 Volts - Operating temperature: – 55°C up to + 200°C (ambient temperature + rise) - KZ 81 - KZ 83 CONSTRUCTION Main characteristics: ■ Applications: - Internal wiring in electronic equipment. - Aircrafts and satellites. ■ Operating frequency: up to 2 000 Hz. ■ Excellent chemical resistance. ■ They are fire retardant (to NFC 32070/C1 French specification). BASE CORE: KZ 04 1- CONDUCTOR: stranded silvered copper wires 2- INSULATION: extruded polytetrafluorethylene (P.T.F.E.) (radial thickness according to the gauges: from 0,15 mm up to 0,18 mm) 4 ▼ 3 2 ▼ ▼ 4- OUTER JACKET: fluoropolymer (FEP) (radial thickness: 0,30 mm nominal) 1 ▼ KZ 04 } 3- SCREEN: polyimide tape and silvered copper braid SCREENED AND JACKETED TRIPLES Type KZ 79-01 KZ 04-01 32 0.035 7 x 0.08 0.24 573 0.10 2.19 2.44 KZ 79-02 KZ 04-02 30 0.055 7 x 0.10 0.30 366 0.10 2.36 2.61 11.7 KZ 79-03 KZ 04-03 28 0.093 7 x 0.13 0.39 211 0.10 2.51 2.76 13.7 KZ 79-04 KZ 04-04 26 0.14 7 x 0.16 0.48 138 0.13 2.90 3.15 18.7 KZ 79-05 KZ 04-05 24 0.22 7 x 0.20 0.60 90 0.13 3.15 3.40 23.1 KZ 79-06 KZ 04-06 22 0.34 7 x 0.25 0.75 57 0.13 3.48 3.73 29.6 KZ 79-07 KZ 04-07 20 0.60 19 x 0.20 1.00 33 0.13 4.10 4.35 42.7 Colour coding: - cores: white + light blue + orange - outer jacket: white 9.85 Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Braid DC Overall diameter resist. Average CONDUCTOR Nom. at 20°C weight Ø mini. maxi. Nom. Cross Ω/Km Construction Gauge strands Ø section n x Ø mm AWG Maxi. Kg/Km mm mm 2 mm mm BASE CORE Reference NFC 93 523 and FILOTEX KZ 81 Screened and jacketed triples High temperature Filotex® PRODUCTS IN THE RANGE - KZ 79 To NF C 93-523 French specification - Operating voltage: 600 Volts - Operating temperature: – 55°C up to + 200°C (ambient temperature + rise) - KZ 81 - KZ 83 CONSTRUCTION Main characteristics: ■ Applications: - Internal wiring in electronic equipment. - Aircrafts and satellites. ■ Operating frequency: up to 2 000 Hz. ■ Excellent chemical resistance. ■ They are fire retardant (to NFC 32070/C1 French specification). BASE CORE: KZ 05 1- CONDUCTOR: stranded silvered copper wires 2- INSULATION: extruded polytetrafluorethylene (P.T.F.E.) (radial thickness according to the gauges: from 0,25 mm up to 0,30 mm) 4 ▼ 3 2 ▼ ▼ 4- OUTER JACKET: fluoropolymer (FEP) (radial thickness: 0,30 mm nominal) 1 ▼ KZ 05 } 3- SCREEN: silvered copper braid SCREENED AND JACKETED TRIPLES Type KZ 81-01 KZ 05-01 32 0.035 7 x 0.08 0.24 573 0.10 2.57 2.82 13.4 KZ 81-02 KZ 05-02 30 0.055 7 x 0.10 0.30 366 0.13 2.87 3.12 17.4 KZ 81-03 KZ 05-03 28 0.093 7 x 0.13 0.39 211 0.13 3.07 3.32 19.9 KZ 81-04 KZ 05-04 26 0.14 7 x 0.16 0.48 138 0.13 3.28 3.53 23.4 KZ 81-05 KZ 05-05 24 0.22 7 x 0.20 0.60 90 0.13 3.56 3.81 28.2 KZ 81-06 KZ 05-06 22 0.34 7 x 0.25 0.75 57 0.13 3.86 4.11 34.8 KZ 81-07 KZ 05-07 20 0.60 19 x 0.20 1.00 33 0.13 4.40 4.65 47.6 KZ 81-08 KZ 05-08 18 0.93 19 x 0.25 1.25 21.5 0.13 5.18 5.53 67.5 KZ 81-09 KZ 05-09 16 1.34 19 x 0.30 1.50 14.6 0.13 5.83 6.18 89.1 KZ 81-10 KZ 05-10 14 1.91 27 x 0.30 1.85 10.5 0.13 6.64 7.00 115 KZ 81-11 KZ 05-11 12 3.18 45 x 0.30 2.45 6.3 0.13 7.89 8.24 169 Colour coding: - cores: white + light blue + orange - outer jacket: white Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Braid DC Overall diameter resist. Average Nom. CONDUCTOR weight at 20°C Ø maxi. mini. Cross Nom. Ω/Km Construction Gauge strands section Ø n x Ø mm AWG Maxi. Kg/Km mm mm 2 mm mm BASE CORE Reference NFC 93 523 and FILOTEX KZ 83 Screened and jacketed triples High temperature Filotex® PRODUCTS IN THE RANGE - KZ 79 To NF C 93-523 French specification - Operating voltage: 1 000 Volts - Operating temperature: – 55°C up to + 200°C (ambient temperature + rise) - KZ 81 - KZ 83 CONSTRUCTION Main characteristics: ■ Applications: - Internal wiring in electronic equipment. - Aircrafts and satellites. ■ Operating frequency: up to 2 000 Hz. ■ Excellent chemical resistance. ■ They are fire retardant (to NFC 32070/C1 French specification). BASE CORE: KZ 06 1- CONDUCTOR: stranded silvered copper wires 2- INSULATION: extruded polytetrafluorethylene (P.T.F.E.) (radial thickness according to the gauges: from 0,37 mm up to 0,45 mm) 4 ▼ 3 2 ▼ ▼ 4- OUTER JACKET: fluoropolymer (FEP) (radial thickness: 0,30 mm nominal) 1 ▼ KZ 06 } 3- SCREEN: silvered copper braid SCREENED AND JACKETED TRIPLES CONDUCTOR Type Cross Gauge Construction section AWG n x Ø mm mm2 Braid DC Overall diameter resist. Nom. Average at 20°C Ø mini. maxi. weight Nom. Ω/Km strands Ø mm Kg/Km mm Maxi. mm KZ 83-01 KZ 06-01 32 0.035 7 x 0.08 0.24 573 0.13 3.26 3.51 20.9 KZ 83-02 KZ 06-02 30 0.055 7 x 0.10 0.30 366 0.13 3.39 3.64 22.7 KZ 83-03 KZ 06-03 28 0.093 7 x 0.13 0.39 211 0.13 3.58 3.83 25.8 KZ 83-04 KZ 06-04 26 0.14 7 x 0.16 0.48 138 0.13 3.80 4.05 29.6 KZ 83-05 KZ 06-05 24 0.22 7 x 0.20 0.60 90 0.13 4.08 4.33 34.5 KZ 83-06 KZ 06-06 22 0.34 7 x 0.25 0.75 57 0.13 4.40 4.65 42.1 KZ 83-07 KZ 06-07 20 0.60 19 x 0.20 1.00 33 0.13 5.09 5.34 57.6 KZ 83-08 KZ 06-08 18 0.93 19 x 0.25 1.25 21,5 0.13 5.70 6.15 76.2 KZ 83-09 KZ 06-09 16 1.34 19 x 0.30 1.50 14,6 0.13 6.15 6.60 94.8 KZ 83-10 KZ 06-10 14 1.91 27 x 0.30 1.85 10,5 0.13 7.14 7.59 127 KZ 83-11 KZ 06-11 12 3.18 45 x 0.30 2.45 6,3 0.13 8.49 8.94 188 Colour coding: - cores: white + light blue + orange - outer jacket: white Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. BASE CORE Reference NFC 93 523 and Filotex ETF Unscreened hook-up wires High temperature Filotex® PRODUCTS IN THE RANGE - ETF To MIL W 16878/6 U.S. specification - Operating voltage: 250 Volts - Operating temperature: – 55°C up to + 200°C (ambient temperature + rise) - EF - EEF Main characteristics: CONSTRUCTION ■ Applications: - Internal wiring in electronic equipment. - Aircrafts and satellites. ■ Operating frequency: up to 2 000 Hz. ■ Excellent chemical resistance. ■ They are fire retardant (to NFC 32070/C1 French specification). 1- CONDUCTOR: stranded silvered copper wires 2 ▼ 1 ▼ 2- INSULATION: extruded polytetrafluorethylene (P.T.F.E.) UNSCREENED HOOK-UP WIRES Reference FILOTEX Gauge AWG Cross section mm2 Construction n x Ø mm Overall diameter Nominal Ø mm mini. maxi. mm ETF 32-07 32 0.035 7 x 0.079 0.24 0.50 0.61 ETF 30-07 30 0.057 7 x 0.102 0.30 0.56 0.66 ETF 30-19 30 0.054 19 x 0.06 0.30 0.56 0.66 ETF 28-07 28 0.089 7 x 0.127 0.39 0.63 0.74 ETF 28-19 28 0.093 19 x 0.079 0.39 0.63 0.74 ETF 26-07 26 0.14 7 x 0.16 0.48 0.74 0.84 ETF 26-19 26 0.15 19 x 0.102 0.48 0.74 0.84 ETF 24-07 24 0.22 7 x 0.203 0.59 0.86 0.96 ETF 24-19 24 0.24 19 x 0.127 0.63 0.86 0.96 ETF 22-07 22 0.36 7 x 0.254 0.74 1.01 1.12 ETF 22-19 22 0.38 19 x 0.16 0.78 1.01 1.12 ETF 20-07 20 0.56 7 x 0.32 0.95 1.22 1.32 ETF 20-19 20 0.61 19 x 0.203 0.97 1.22 1.32 Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. CONDUCTOR EF Unscreened hook-up wires High temperature Filotex® PRODUCTS IN THE RANGE - ETF To MIL W 16878/4 U.S. specification - Operating voltage: 600 Volts - Operating temperature: – 55°C up to + 200°C (ambient temperature + rise) - EF - EEF Main characteristics: CONSTRUCTION ■ Applications: - Internal wiring in electronic equipment. - Aircrafts and satellites. ■ Operating frequency: up to 2 000 Hz. ■ Excellent chemical resistance. ■ They are fire retardant (to NFC 32070/C1 French specification). 1- CONDUCTOR: stranded silvered copper wires 2 ▼ 1 ▼ 2- INSULATION: extruded polytetrafluorethylene (P.T.F.E.) UNSCREENED HOOK-UP WIRES Reference FILOTEX Gauge AWG Cross section mm2 Construction n x Ø mm Overall diameter Nominal Ø mm mini. maxi. mm EF 32-07 32 0.035 7 x 0.079 0.24 0.66 0.86 EF 30-07 30 0.057 7 x 0.102 0.30 0.71 0.91 EF 30-19 30 0.054 0.34 0.71 0.91 EF 28-07 28 0.089 7 x 0.127 0.39 0.79 1.00 EF 28-19 28 0.093 19 x 0.079 0.39 0.79 1.00 EF 26-07 26 0.14 7 x 0.16 0.48 0.89 1.10 EF 26-19 26 0.15 19 x 0.102 0.48 0.89 1.10 EF 24-07 24 0.22 7 x 0.203 0.59 1.02 1.22 EF 24-19 24 0.24 19 x 0.127 0.63 1.02 1.22 EF 22-07 22 0.36 7 x 0.254 0.74 1.17 1.37 EF 22-19 22 0.38 19 x 0.16 0.78 1.17 1.37 EF 20-07 20 0.56 7 x 0.32 0.95 1.37 1.57 EF 20-19 20 0.61 19 x 0.203 0.97 1.37 1.57 EF 18-07 18 0.89 7 x 0.404 1.19 1.63 1.88 EF 18-19 18 0.96 19 x 0.254 1.21 1.63 1.88 EF 16-19 16 1.23 19 x 0.287 1.45 1.85 2.21 19 x 0.06 Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. CONDUCTOR EEF Unscreened hook-up wires High temperature Filotex® PRODUCTS IN THE RANGE - ETF To MIL W 16878/5 U.S. specification - Operating voltage: 1 000 Volts - Operating temperature: – 55°C up to + 200°C (ambient temperature + rise) - EF - EEF CONSTRUCTION Main characteristics: ■ Applications: - Internal wiring in electronic equipment. - Aircrafts and satellites. ■ Operating frequency: up to 2 000 Hz. ■ Excellent chemical resistance. ■ They are fire retardant (to NFC 32070/C1 French specification). 1- CONDUCTOR: stranded silvered copper wires 2 ▼ 1 ▼ 2- INSULATION: extruded polytetrafluorethylene (P.T.F.E.) UNSCREENED HOOK-UP WIRES Reference FILOTEX Gauge AWG Cross section mm2 Construction n x Ø mm Nominal Ø mm mini. maxi. mm EEF 32-07 32 0.035 7 x 0.079 0.24 0.91 1.12 EEF 30-07 30 0.057 7 x 0.102 0.30 0.97 1.17 EEF 30-19 30 0.054 0.34 0.97 1.17 EEF 28-07 28 0.089 7 x 0.127 0.39 1.04 1.24 EEF 28-19 28 0.093 19 x 0.079 0.39 1.04 1.24 EEF 26-07 26 0.14 7 x 0.16 0.48 1.14 1.35 EEF 26-19 26 0.15 19 x 0.102 0.48 1.14 1.35 EEF 24-07 24 0.22 7 x 0.203 0.59 1.27 1.47 EEF 24-19 24 0.24 19 x 0.127 0.63 1.27 1.47 EEF 22-07 22 0.36 7 x 0.254 0.74 1.42 1.63 EEF 22-19 22 0.38 19 x 0.16 0.78 1.42 1.63 EEF 20-07 20 0.56 7 x 0.32 0.95 1.63 1.83 EEF 20-19 20 0.61 19 x 0.203 0.97 1.63 1.83 EEF 18-07 18 0.89 7 x 0.404 1.19 1.88 2.13 EEF 18-19 18 0.96 19 x 0.254 1.21 1.88 2.13 EEF 16-19 16 1.23 19 x 0.287 1.45 2.10 2.41 19 x 0.06 Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Overall diameter CONDUCTOR SM & DFSG Subminiature hook-up wires Filotex® PRODUCTS IN THE RANGE - SM/DFSG To FILOTEX specification - Operating voltage: 48 Volts RMS - Operating temperature: - 40°C up to + 75°C (ambient temperature + rise) Main characteristics: ■ Very flexible wires for connection or internal wiring of subminiature lightweight units. ■ Very small size. ■ They are flame retardant (to NFC 32070/C2 French specification). CONSTRUCTION 1- CONDUCTOR: - stranded bare copper wires for serie SM 105,245,485 - solid tinned copper wires for serie SM 30 2- INSULATION: flexible polyvinyl chloride (PVC) serie SM 3- SCREEN: bare copper braid 4- OUTER JACKET: flexible polyvinyl chloride (PVC) serie DFSG ▼ 2 ▼ 1 ▼ 1 ▼ ▼ ▼ 4 3 2 UNSCREENED EXTRA-FLEXIBLE HOOK-UP WIRES Reference FILOTEX Nature Cross section mm2 29 0.07 1 x 0.30 0.55 0.65 1.1 34 0.02 10 x 0.05 0.55 0.65 0.7 30 0.05 24 x 0.05 0.65 0.75 0.9 27 0.10 48 x 0.05 0.85 0.95 1.8 Solid tinned copper SM 30 SM 105 SM 245 SM 485 Average weight Gauge AWG stranded bare copper Construction mini maxi n x Ø mm mm Kg/Km EXTRA-FLEXIBLE SCREENED AND JACKETED PAIRS BASE CORE Nb. of cores Reference FILOTEX CONDUCTOR nominal Ø Type Cross Construction core section mm mm2 n x Ø mm Ø over lay up of cores mm Braid Nom. Ø strands mm Outer Jacket nature Nominal overall diameter Average weight mm Kg/Km 2 DFSG 105 SM 105 0.02 10 x 0.05 0.60 1.20 0.07 PVC 1.8 x 1.2 3.6 2 DFSG 245 SM 245 0.05 24 x 0.05 0.70 1.40 0.07 PVC 2.0 x 1.3 4.9 2 DFSG 485 SM 485 0.10 48 x 0.05 0.90 1.80 0.07 PVC 2.4 x 1.5 7.0 Colour coding: - cores: white + red - outer jacket: white Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Overall diameter CONDUCTOR FT & FR Unscreened extra-flexible hook-up wires Filotex® PRODUCTS IN THE RANGE - FT & FR To FILOTEX specification - Operating voltage: 250 Volts RMS - Operating temperature: - 40°C up to + 90°C (ambient temperature + rise) Main characteristics: ■ Extra-flexible wires for applications requiring a great flexibility and subjected to low strains. ■ They are flame retardant (to NFC 32070/C2 French specification). CONSTRUCTION 1- CONDUCTOR: - stranded bare copper wires (serie FR) - stranded tinned copper wires (serie FT) 2 ▼ 1 ▼ 2- INSULATION: flexible polyvinyl chloride (PVC) EXTRA-FLEXIBLE UNSCREENED HOOK-UP WIRES FT 5 FT 10 FT 15 FT 30 FT 40 FR 1 FR 3 FR 7 FR 12 FR 19 Overall Average diameter mini maxi weight Kg/Km mm TINNED COPPER 31 28 26 24 22 0.04 0.08 0.12 0.24 0.31 5 x 0.10 10 x 0.10 15 x 0.10 30 x 0.10 40 x 0.10 0.7 1.0 1.1 1.3 1.5 0.9 1.2 1.3 1.5 1.7 1.00 1.90 2.40 3.80 5.00 BARE COPPER 27 22 19 16 14 0.10 0.30 0.70 1.20 1.90 24 x 0.07 72 x 0.07 168 x 0.07 (7x45) x 0.07 (7x72) x 0.07 1.0 1.5 1.85 2.35 2.6 1.2 1.7 2.15 2.65 3.0 2.1 4.8 9.5 16.2 24.0 Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. CONDUCTOR Reference Cross FILOTEX Nature Gauge section Construction AWG n x Ø mm mm2 FTM Extra-flexible multicore cable Filotex® PRODUCTS IN THE RANGE - FTM To FILOTEX specification - Operating voltage: 250 Volts - Operating temperature: - 20°C up to + 80°C (ambient temperature + rise) Main characteristics: ■ These cables combine very great flexibility with extremely good mechanical resistance due to the cotton braid acting as a strain member. ■ They are flame retardant (to NFC 32070/C2 French specification). CONSTRUCTION 1- CONDUCTOR: stranded tinned copper wires 2- INSULATION: flexible polyvinyl chloride (PVC) 3 ▼ 1 ▼ 2 ▼ 3- OUTER JACKET: black flexible polyvinyl chloride (PVC) UNSCREENED EXTRA-FLEXIBLE MULTICORE CABLE Average weight Colour coding of cores Kg/Km 2 FTM 2 22 0.31 40 x 0.10 1.6 5.30 5.70 39 White, Grey 3 FTM 3 24 0.24 30 x 0.10 1.4 5.30 5.70 38 White, Blue, Red 4 FTM 4 24 0.24 30 x 0.10 1.4 5.30 5.70 43 White, Blue, Red, Green Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. BASE CORE Overall Nb. CONDUCTOR Nominal diameter Reference of Ø FILOTEX Gauge Cross Construction mini maxi cores core section AWG mm2 n x Ø mm mm mm Hook-up wires for wire-wrapping Filotex® PRODUCTS IN THE RANGE - Wire Wrapping To NFC 93 522 French specification - Operating voltage: 350 Volts - Operating temperature: according to the insulation Main characteristics: ■ These wires are designed for wire-wrapping connection consisting in winding a wire helically around a metallic terminal without any soldering operation. ■ Fast and robust connections. CONSTRUCTION 1- CONDUCTOR: solid silvered copper wires WIRE-WRAPPING PROCEDURE Method A: conductor only wrapped around pin. Method B: conductor with insulation wrapped around pin (better elasticity of connection). 2 ▼ 1 ▼ 2- INSULTATION: polyvinyl chloride (PVC) or ethylene and tetrafluorethylene copolymer (E.T.F.E.) or polyfluoride of vinylidene (PVF2) or polytetrafluorethylene (P.T.F.E.) A B HOOK-UP WIRES FOR WIRE-WRAPPING KW 01-30 C1 WCP 30 30 0.05 1 x 0.254 PVC 0.48 0.58 0.73 KW 01-28 C1 WCP 28 28 0.08 1 x 0.32 PVC 0.57 0.67 1.05 KW 01-26 C1 WCP 26 26 0.12 1 x 0.40 PVC 0.69 0.79 1.65 KW 01-24 C1 WCP 24 24 0.20 1 x 0.51 PVC 1.00 1.10 2.80 KW 02-30 C1 WCY 30 30 0.05 1 x 0.254 PVF2 0.48 0.58 0.88 KW 02-28 C1 WCY 28 28 0.08 1 x 0.32 PVF2 0.57 0.67 1.25 KW 02-26 C1 WCY 26 26 0.12 1 x 0.40 PVF2 0.69 0.79 1.85 KW 02-24 C1 WCY 24 24 0.20 1 x 0.51 PVF2 1.00 1.10 3.30 KW 02-30 B1 WCZ 30 30 0.05 1 x 0.254 ETFE 0.48 0.58 0.79 KW 02-28 B1 WCZ 28 28 0.08 1 x 0.32 ETFE 0.57 0.67 1.12 KW 02-26 B1 WCZ 26 26 0.12 1 x 0.40 ETFE 0.69 0.79 1.85 KW 02-24 B1 WCZ 24 24 0.20 1 x 0.51 ETFE 1.00 1.10 2.90 KW 03-30 A2 WCT 30 30 0.05 1 x 0.254 PTFE 0.48 0.58 0.88 KW 03-28 A2 WCT 28 28 0.08 1 x 0.32 PTFE 0.57 0.67 1.25 KW 03-26 A2 WCT 26 26 0.12 1 x 0.40 PTFE 0.69 0.79 1.90 KW 03-24 A2 WCT 24 24 0.20 1 x 0.51 PTFE 1.00 1.10 3.30 OPERATING TEMPERATURES Insulation ■ Temperature PCV – 40°C up to + 85°C PVF2 – 60°C up to + 130°C ETFE – 60°C up to + 150°C PTFE – 90°C up to + 200°C For connections on automatic machines, we manufacture these wires with smaller dimensional tolerances. Please, consult us. Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Overall CONDUCTOR Average diameter Insulat. Reference Reference weight Cross Construction NFC 93 522 FILOTEX Gauge section nature mini maxi n x Ø mm AWG Kg/Km mm mm2 FLAT BRAIDS Tinned copper FITE Filotex® PRODUCTS IN THE RANGE To FILOTEX specification - FITE FLAT BRAIDS Main characteristics: ■ ■ CONSTRUCTION - Braids consisting of tinned copper wires. - These braids are ribbon-like structures (only one ribbon) up to FITE 10. - They are flattened (crushed cylinder) for greater sizes. Applications: mainly for connections of mobile contacts, shunts and earthing of mobile equipment (doors, chassis, etc...). The very thin strands used to manufacture these braids make them extremely flexible and give them an excellent flex life. TINNED COPPER FLAT BRAIDS-FITE FITE 01 FITE 02 FITE 03 FITE 04 FITE 05 FITE 06 FITE 07 FITE 08 FITE 09 FITE 10 FITE 11 FITE 12 FITE 13 FITE 14 FITE 15 FITE 16 Construction n x Ø mm Cross section area mm2 Approximate dimensions mm Average weight kg/km Current rating A 26 x 0.12 26 x 0.15 26 x 0.20 39 x 0.20 78 x 0.20 104 x 0.20 130 x 0.15 195 x 0.15 260 x 0.15 390 x 0.15 736 x 0.15 352 x 0.20 384 x 0.25 480 x 0.25 960 x 0.20 800 x 0.20 0.29 0.46 0.81 1.22 2.45 3.26 2.30 3.44 4.60 6.90 13.00 11.10 18.80 23.50 30.20 25.10 2.0 x 0.3 3.0 x 0.4 4.0 x 0.6 4.5 x 0.6 7.0 x 0.7 8.0 x 1.0 6.5 x 0.7 8.0 x 1.0 9.0 x 1.0 11.0 x 1.5 16.0 x 2.0 15.0 x 2.0 21.0 x 2.5 22.0 x 2.5 25.0 x 3.0 20.0 x 2.5 3 4 8 12 25 32 22 35 45 70 130 113 198 235 300 250 3 6 9 12 25 32 21 32 38 50 80 70 116 144 160 150 Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Reference FILOTEX TUBULAR BRAIDS Tinned copper without filler Filotex® PRODUCTS IN THE RANGE To FILOTEX specification - TINNED COPPER TUBULAR BRAIDS Main characteristics: ■ Applications: physical and electrical protection for cable bundles. ■ The diameter of these braids may vary thanks to their very high flexibility, thus facilitating the bundle introduction. CONSTRUCTION Tubular braid made up of tinned copper wires. TINNED COPPER TUBULAR BRAIDS WITHOUT FILLER Construction n x Ø mm Cross section area mm2 Increases overall diameter Average weight Kg/Km 4 6 8 10 12 15 19 112 x 0.20 144 x 0.20 192 x 0.20 192 x 0.25 224 x 0.25 256 x 0.25 320 x 0.25 3.5 4.5 6.0 9.4 11 12.6 15.7 0.8 0.8 0.8 1.0 1.0 1.0 1.0 35 45 60 94 110 135 165 Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Internal Ø nominal mm TUBULAR BRAIDS Tinned copper with filler Filotex® PRODUCTS IN THE RANGE To FILOTEX specification - TINNED COPPER TUBULAR BRAIDS Main characteristics: CONSTITUTION - Tubular braid made up of tinned copper wires around a central filler. ■ Applications: physical and electrical protection for cable bundles. ■ The central filler prevents any deformation of the braid and is withdrawn when introducing the bundles. ■ The cover factor is about 75 % (Kr = 0,75) or 80 % (Kr = 0,80) according to NF C 93521§ 1.7.5. French specification. TINNED COPPER TUBULAR BRAIDS WITH FILLER 52 104 55 304/1 52 106 55 306/1 52 108 55 308/1 52 110 55 310/1 52 112 55 312/1 52 115 55 315/1 55 955/1 52 120 55 320/1 59 956/1 59 957/1 59 958/1 Internal Ø mm Overall Ø mm Covering coefficient Kr Average weight Kg/Km Nominal cross section mm2 4 4.5 6.5 8 8.5 10 10.5 12 12.5 15 15.5 18 20 18.5 20.8 22 25 30 22.8 26.0 31.0 14.0 15.0 21.4 22.0 28.2 29.0 35.1 36.0 42.0 44.0 52.3 54.0 79.0 105.0 108.0 120.0 182.0 218.0 1.37 6 0.75 0.80 0.75 0.80 0.75 0.80 0.75 0.80 0.75 0.80 0.75 0.80 0.80 0.75 0.80 0.80 0.80 0.80 2.00 2.60 3.40 4.00 5.00 7.20 9.60 11.30 17.60 20.00 Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Reference FILOTEX TUBULAR SUPERPOLYAMIDE BRAIDS Filotex® High temperature To FILOTEX specification PRODUCTS IN THE RANGE - Maximum operating temperature: + 135°C - TUBULAR SUPERPOLYAMIDE BRAIDS CONSTRUCTION - Tubular braid made up of superpolyamide strands Main characteristics: ■ Applications: mechanical protection of cables without any faradization screen. ■ Very high toughness. ■ Very significant breaking load. ■ Very good abrasion resistance. ■ Lightweight in comparison with corresponding copper braid or steel braid. TUBULAR SUPERPOLYAMIDE BRAIDS Ø nominal mm Construction 3 4 6 8 10 12 15 18 20 25 30 35 40 32 x 0.29 72 x 0.29 96 x 0.29 128 x 0.29 160 x 0.29 192 x 0.29 200 x 0.29 240 x 0.29 288 x 0.29 336 x 0.29 224 x 0.40 280 x 0.40 335 x 0.40 n x Ø mm Increases overall diameter mm 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.6 1.6 1.6 Lightweight braids Average weight Kg/Km Construction n x Ø mm Increases overall diameter mm Average weight Kg/Km 4.7 6.7 9.0 13.0 18.0 21.0 25.0 28.0 35.0 41.0 64.0 70 80.0 20 x 0.29 24 x 0.29 32 x 0.29 48 x 0.29 56 x 0.29 64 x 0.29 80 x 0.29 88 x 0.29 96 x 0.29 96 x 0.29 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.8 2.2 3.2 4.5 5.2 6.2 7.4 8.6 8.9 10.0 Passing-on or reproducing any part of the document, use or communication of its content is not permitted without prior written authorization. Filotex 96/09. Standard braids Internal Equivalence table of american wire gauges for diameters and cross section areas GAUGES AWG 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1/0 2/0 3/0 4/0 DIAMETERS* Mils 2,0 2,2 2,5 2,8 3,1 3,5 4,0 4,5 5,0 5,6 6,3 7,1 8,0 8,9 10,0 11,3 12,6 14,2 15,9 17,9 20,1 22,6 25,3 28,5 32,0 35,9 40,3 45,3 50,8 57,1 64,1 72,0 80,8 90,7 101,9 114,4 128,5 144,3 162,0 181,9 204,3 229,4 257,6 289,3 324,9 364,8 409,6 460,0 CROSS SECTION AREAS D.C. RESISTANCES AT 20°C mm Circ. mils sq. mm (mm2) Ohm / kFt Ohm / Km 0,050 0,055 0,063 0,071 0,079 0,089 0,102 0,114 0,127 0,142 0,160 0,180 0,203 0,226 0,254 0,287 0,320 0,361 0,404 0,455 0,511 0,574 0,643 0,724 0,813 0,912 1,020 1,150 1,290 1,450 1,630 1,830 2,050 2,300 2,588 2,906 3,264 3,655 4,115 4,620 5,189 5,827 6,543 7,348 8,252 9,266 10,400 11,680 4,00 4,84 6,25 7,84 9,61 12,30 16,00 20,30 25,00 31,40 39,70 50,40 64,00 79,20 100,00 128,00 159,00 202,00 253,00 320,00 404,00 511,00 640,00 812,00 1.020 1.290 1.620 2.050 2.580 3.260 4.110 5.180 6.530 8.230 10.380 13.090 16.510 28.820 26.240 33.090 41.740 52.620 66.360 83.690 105.600 133.100 167.800 211.600 0,0020 0,0025 0,0032 0,0039 0,0049 0,0062 0,0081 0,0103 0,0127 0,0159 0,0201 0,0255 0,0324 0,0401 0,0507 0,0649 0,0806 0,1020 0,1280 0,1620 0,2050 0,2590 0,3240 0,4110 0,5190 0,6530 0,8230 1,0400 1,3100 1,6500 2,0800 2,6300 3,3100 4,1700 5,2600 6,6300 8,3700 10,5500 13,3000 16,7700 21,1500 26,6700 33,6200 42,4100 53,4900 67,4300 85,0100 107,2200 2590,0 2140,0 1660,0 1320,0 1080,0 847,0 648,0 512,0 415,0 331,0 261,0 206,0 162,0 131,0 104,0 81,20 65,30 51,40 41,00 32,40 25,70 20,30 16,20 12,80 10,10 8,05 6,39 5,05 4,02 3,18 2,52 2,00 1,59 1,26 0,9988 0,7925 0,6281 0,4981 0,3952 0,3134 0,2485 0,1971 0,1563 0,1239 0,09825 0,07793 0,06182 0,04901 8498,00 7021,00 5446,00 4330,00 3540,00 2780,00 2130,00 1680,00 1360,00 1080,00 587,00 675,00 532,00 430,00 340,00 266,00 214,00 169,00 135,00 106,00 84,20 66,60 53,20 41,90 33,20 26,40 21,00 16,60 13,20 10,40 8,28 6,56 5,21 4,14 3,277 2,600 2,061 1,634 1,296 1,028 0,8152 0,6466 0,5128 0,4065 0,3223 0,2557 0,2028 0,1608 *Nominal diameter of solid bare copper wire Conversion factors LENGTH CROSS SECTION AREA WEIGHT RESISTANCE TEMPERATURE KNOWING MULTIPLY BY TO OBTAIN Millimeters Mils Millimeters Inches Feet Meters Square millimeters (mm2) Circular Mils Square millimeters (mm2) Square Inches Pounds (Lbs) Kilograms Pounds/MFt Gram/Meter (kg/km) Ohm/Ft Ohm/mètre(Ω /m) °C (Celsius degree)———> °F (Fahrenheit degree)—> 39,37 0,0254 0,03937 25,4 0,3048 3,281 1973,5 0,0005067 0,00155 645,2 0,4536 2,205 1,488 0,672 3,2808 0,3048 To multiply by 9/5 and to add 32 To subtract 32 and to multiply by 5/9 Mils Millimeters Inches Millimeters Meters Feet Circulars Mils Square millimeters (mm2) Square Inches Square millimeters (mm2) Kilograms Pounds Gram/Meter (kg/km) Pounds/MFt Ohm/meter Ohm/Ft °F °C Conversion from english system to metric and vice versa
Similar documents
Clearance sales vente de liquidation Ausverkauf uitverkoop
promotion price € 6,95 - € 1,95
More informationproduct catalog
Appliance, Hook-up, Panel and Motor Lead Wire UL: 105°C, 600V, MTW, VW-1 / 1032: 1000V CSA: 105°C, 600V, FT1
More information