Redland roofing components and systems

Transcription

Redland roofing components and systems
Redland roofing components and systems
8
From roof tiles and underlays to eaves systems and ridges, we have a comprehensive range
of roof products and systems. All elements of our roofs are carefully designed, tested and
manufactured to give value, visual appeal and a long-lasting weathertight performance.
10
1
4
6
11
7
9
12
5
Product
Page
1
Slates, Plain Tiles & Profile Tiles
40 - 221
2
Underlays
224 - 225
3
Eaves Systems
226 - 227
4
Verge Systems
228 - 231
5
Hip Systems
232 - 237
6
Valley Systems
238 - 239
7
Abutment Systems
240 - 241
8
Ridge Systems
242 - 253
9
Ventilation Tiles
254 - 255
10
Ornamental Tiles
260 - 261
11
Internal/External Angles
279
12
Clips & Nails
274 - 281
Technical data for Slates, Plain Tiles and Profile Tiles
262 - 270
Fittings Colour Range
272 - 273
INTERACTIVE SECTION
2
3
www.redland.co.uk/components
Components & Fittings
222
Scan here for details
of our guarantees
223
Spirtech 100, 250 & Underlay Support Tray
Spirtech 250 is a high quality, quadruple layer vapour permeable underlay. It provides
exceptional strength and durability, with excellent vapour transmission properties.
Eaves (Spirtech 100/250)
Ridge (Spirtech 100/250)
Guidance Notes
• Spirtech 100 & 250 must always be used in accordance with Redland’s
recommendation for correct ventilation.
• All penetrations in the ceiling should be well sealed.
• Leave the underlay short of the apex by 30mm where the insulation is either installed
at ceiling level or rebated between the rafters.
• Ventilate at high-level to a minimum value of 5,000mm² per linear metre using Rapid
Vented Ridge or 10,000mm² per metre using DryVent Ridge. However, tile vents can
be used if it is not possible to install a dry-fix ventilated ridge system.
• When laid unsupported Spirtech 100 or 250 must be draped across supports with a
10mm drape and not pulled taut.
• At the eaves avoid carrying Spirtech 100 or 250 into the gutter by fitting Underlay
Support Trays.
• Spirtech 100 & 250 must be stored flat or upright on a clean, level surface, under
cover and out of direct sunlight.
• It is best practice to apply the external roof covering as soon as the installation of
Spirtech 100 or 250 is complete.
x
Spirtech 100 is a high quality, triple layer vapour permeable underlay offering a
lightweight alternative to Spirtech 250.
The Underlay Support Tray provides both continuous support for the underlay
at the eaves and a UV resistant gutter drip.
Spirtech 100 & 250
• With its high vapour transmission capacity,
excellent nail hole sealing and abrasion
resistant surface, Spirtech is ideal for all types
of pitched roofing
• Spirtech 100 & 250 are manufactured from spun
bond polypropylene
• Spirtech 250 has an additional reinforcement grid,
so is strong and durable, yet lightweight and easy
to install
• Spirtech 100 is part of the
range of
components
Underlay Support Tray
• Replaces the need for a timber tilting fillet or
additional length of UV resistant underlay
• Easy to install
• Guaranteed weathertight and secure for 15 years
Authority & Performance
• Spirtech 100 & 250 comply with BS 5250 :2011,
BS 5534:2003 and BS EN 13859-1:2010
• Awarded British Board of Agrément Certification,
certification number 05/4283
• Spirtech 250 is backed by Redland’s 15-year Roof
System Guarantee
224
Compatibility
• Spirtech 100 & 250 can be used with the
complete Redland range of tiles and slates
• Not adversely affected by any of the standard
construction materials used in the roof or by any
of the commonly used timber preservatives
• Eaves Clips and Reform Eaves Filler Units can be
easily fixed through the Underlay Support Tray
• Fascia board height will vary with rafter pitch,
roof construction and tile type. Please contact
Technical Solutions
• Spirtech 100 & 250 can be used without
Eaves Ventilation when used in conjunction
with a well sealed ceiling and ridge or other high
level ventilation
Physical Properties Test Method
Spirtech 250
Spirtech 100
Water vapour
permeability
DIN 52 615
1200g/m2 24 hrs
1800g/m2 24 hrs
Water vapour
resistance
BS 7374
0.15 MNs/g
0.1 MNs/g
Tensile strength
- along the roll
- across the roll
BS EN 12311-2
BS EN 12311-2
450 N / 5cm
390 N / 5cm
200 N / 5cm
130 N / 5cm
Nail tear force
- along the roll
- across the roll
BS EN 12310-2
BS EN 12310-2
340 N
360 N
130 N
150 N
Resistance to
water penetration BS EN 20811
3.0m
3.0m
Fire Rating
BS EN 13501-1
E
Resistance to
(UV) light
BS EN 1297
4 months
Spirtech 250
Spirtech 100
Colour
Dark Grey
Dark Grey
Material
4 layer
Spunbond
Polypropylene fleece
Polypropylene grid
Polypropylene vapour
Polypropylene fleece
transmission film
3 layer
Spunbond
Polypropylene fleece
Polypropylene vapour
Polypropylene fleece
transmission film
Weight
152g/m2
100g/m2
Roll length
50m
50m
E
Roll width
1.5m
1.0m
4 months
Roll area
75m2
50m2
Guidance Notes: Underlay Support Tray
• Minimum pitch will depend on the minimum pitch of the roof covering.
• Maximum pitch is 55° for use with RedVent 25 Over-Fascia Vent or 80° without. A
softwood clip batten may be required when using a RedVent 25 Over-Fascia Vent,
subject to tile fixing specification.
• Fix Underlay Support Tray to top of fascia board at centres not greater than 300mm.
Underlay Support Trays must butt up against one another and not overlap.
For Cambrian, DuoPlain and Plain Tiles remove section of tray by cutting along the
score line. Lay underlay over Underlay Support Tray with bottom edge in line with
top of fascia.
05/4283
INTERACTIVE SECTION
www.redland.co.uk/underlays
Spirtech 100/250 & Underlay
225
RedVent Eaves Ventilation System
Redvent 25 Over-Fascia Vent
The RedVent Eaves Ventilation System provides continuous over-fascia eaves ventilation
for use when insulation is laid between or on top of the horizontal ceiling joists.
The RedVent 25 Over-Fascia Vent provides unobtrusive continuous ventilation at the
eaves for use where the insulation is installed either between or above the rafters.
Features
• Ventilates to comply with BS 5250:2011,
therefore reducing the risk of harmful
condensation in the roof
• Guaranteed weathertight and secure for 10 or
15 years depending on project type
• Suitable for rafter spacing between 350-600mm
centres (subject to pack used). Use extension
trays where the top of the insulation is greater
than 450mm from the fascia when measured up
the rafter
• Removes the need for unsightly grilles in the
soffit board which over time could become
clogged
• Eliminates the need for a tilting fillet and reduces
the required height of the fascia board
• Can be installed with or without a soffit board
• RedVent Eaves Ventilation system is part of the
range of components
Features
• Ventilates to comply with BS 5250 :2011,
therefore reducing the risk of harmful
condensation in the roof
• Guaranteed weathertight and secure for 15 years
• Used for any combination of rafter spacing
• Can be installed with or without a soffit board
• Eaves closure is achieved for Regent, Grovebury,
Landmark Double Pantile and Norfolk Pantile
by specifying the corresponding Reform Eaves
Filler Unit
• Eaves closure is achieved for Old Hollow
and Cathedral Clay Pantiles by specifying the
corresponding Comb Filler Unit
Compatibility
• Suitable for use with most pitched roofing
materials
• Compatible with all of the Redland range of
Eaves Clips
• Where Eaves Clips or Reform Eaves Filler Units
are required for use with a particular tile profile,
it is acceptable to fix them through the Fascia
Grille of the RedVent Eaves Ventilation System
Performance
• Minimum pitch will depend on the minimum
pitch of the roof covering
• Maximum pitch varies with tile used. Please
contact Technical Solutions Hotline 08708 702595
• The effective ventilation area per metre run of
eaves is 14,600mm²
• Mechanically fix all tiles at the eaves
• Fit to straight and level softwood fascia
Compatibility
• Suitable for use with most pitched roofing materials
• Where Eaves Clips, eaves filler units or underlay
support trays are required, a 25mm x 25mm
softwood clip batten should be secured through
the RedVent 25 Over-Fascia Vent into the fascia
board with 90mm x 3.35mm galvanised nails
Performance
• Minimum pitch will depend on the minimum
pitch of the roof covering
• Maximum pitch varies with tile used. Please
contact Technical Solutions Hotline 08708 702595
• The effective ventilation area per metre run of
eaves is 25,000mm2
RedVent 25 Over-Fascia Vent, eaves 15º pitch (Grovebury)
INTERACTIVE SECTION
www.redland.co.uk/eaves
Redvent Eaves Ventilation System
226
Fascia Grille
Eaves Ventilation Tray
Eaves Vent 450 - 600mm
Eaves Vent 350 - 450mm
Q
R
600
450
634
484
Guidance Notes
• Install a 4mm thick tilting fillet with a positive fall to support underlay over the
Fascia Vent.
• Do not extend underlay into the gutter unless 25mm spacer blocks are
positioned behind the gutter brackets.
• Suitable for softwood fascia boards 25mm thick and above.
• No rafter tray required when underlay is fully supported by insulation.
• For fascia board heights contact Technical Solutions.
• The gutter’s size and position will need to be calculated to ensure that
rainwater discharges directly into it.
Components
Each RedVent 25 Over-Fascia Vent pack contains:
• 12 Fascia Grilles (Polypropylene – black) sufficient for 6 metres of eaves.
INTERACTIVE SECTION
www.redland.co.uk/eaves
Redvent 25 Over-Fascia Vent
227
Cloaked Verge System
The Cloaked Verge System continues the tiling over the gable end using a one piece
concrete tile. The system has very high resistance to storm damage and with no
mortar required it removes concerns about mortar failure.
Features
• Easy to lay as it interlocks to the next tile
• The quickest and easiest method of installing
profiled verge tiles
• Provides a neat finish to the verge
• Tried and tested and complies with BS 5534
requirements for mechanical fixing
• Complies with BS EN 490 :2011 (concrete
Cloaked Verge) and BS 8000-6:1990
• Guaranteed weathertight and secure for 15
years when used with the Redland range of tiles
Concrete Cloaked Verge System with Vertical Tiling (Regent)
Compatibility
• Available for all our profiled tiles except Norfolk
Pantile, 49 Tile and Old Hollow Clay Pantile
Performance
• There is no maximum pitch on lean-to roofs or
where lead roll details are used
• On duo-pitch roofs above 45º the top cloaked
verge tiles must be cut to a mitre
• Minimum pitch will depend upon the minimum
pitch for the tile profile and surface finish
• Minimum headlap will depend upon tile profile,
surface finish and rafter pitch
• Maximum headlap is 125mm (71mm
for Cathedral)
• Maximum pitch of cloaked verge depends upon
maximum pitch of ridge/monoridge system
Guidance Notes
• When setting out the roof, the verge overhang should be the same at both verges.
The use of Half Tiles (Two Thirds Tile for Cathedral) in each course will allow the
overhang to be reduced to a minimum.
• Cloaked Verge Tiles are not suitable for raking verges.
• Every Cloaked Verge Tile must be nail fixed, and the integral nylon plug must
interlock with the Cloaked Verge Tile in the course below.
• The left-hand Cloaked Verge Tile on the eaves course must be clipped to the
adjacent tile using a ‘C’ clip (9179). This is supplied in every Block-end Ridge Tile pack
(not applicable to Cathedral).
• Finish ridge with Block End Ridge Tiles.
• An undercloak should be installed between the battens and the structure, touching
the inside face of the cloaked verge tile, to prevent bird ingress.
• At top edge abutments, a lead flashing should dress down the face of the cloak to
provide a full weathertight covering. The flashing length will be dependent on the
rafter pitch.
• In cases where no batten end fixing is available on roof pitches of 30º and above, a
second batten is required to support the main batten. It is essential to secure the
second batten over at least two rafters.
• Where timber sarking is used over the main roof area, the tiling battens should rest
on the external brickwork or cladding (see detail shown). On overhanging verges,
the final counterbatten should be 6mm thinner to allow for undercloak.
• At the eaves, for Landmark Double Pantile, Regent and Grovebury Tiles, Reform
Eaves Filler Units should be cut to fit the inside profile of the Cloaked Verge Tiles.
Components
• Cloaked Verge Tiles are made of concrete (clay for Cathedral), in colours to match
the main roof tiles.The system consists of Left-hand and Right-hand Cloaked Verge
Tiles and Half Tiles (Two Thirds Tile for Cathedral). Block-end Ridge Tiles will be
required for all ridge situations.
Profile
A
Cathedral
Clay Pantile
65
Landmark
Double Pantile
47
Half tile
Concrete Cloaked Left-hand Concrete Cloaked Right-hand
Top of batten
Landmark
Double Roman
37
Regent
Grovebury
50 Double Roman
Renown
49
47
37
30
INTERACTIVE SECTION
Module increased by 150mm
when Half Tiles are used
Concrete Cloaked Verge
228
Concrete Cloaked Verge System with Timber Sarking (Regent)
Concrete Cloaked Left-hand
Concrete Cloaked Right-hand
www.redland.co.uk/verges
Cloaked Verge
229
Ambi-Dry Verge & Slate 10 Dry Verge Systems
The Ambi-Dry Verge System provides a neat, maintenance-free verge for most of
our slates and profile tiles. With very high resistance to storm damage and with no
mortar required, it removes concerns about mortar failure.
Ambi-Dry Verge System with Overhang (Cambrian)
Guidance Notes
• To ensure that the Ambi-Dry Verge System is located correctly, all battens for
Cambrian, Slate 10 and Stonewold II should oversail the bargeboard, brickwork
or cladding by 50mm (60mm for other tiles) and be sawn off square (see
details opposite).
• For Cambrian use Standard States and Slate-and-a-halves alternately on both verges.
• For all other slates use Standard Slates with interlock removed and Left-hand Half
Slates alternately on left-hand verges. Use Standard Slates and Right-hand Half Slates
alternately on right-hand verges.
• The Ambi-Dry Verge System is not suitable for raking verges.
• At the eaves, an Eaves Stop End should be used to prevent both the ingress of
water and birds while providing the fixing position for the ambi-dry eaves clip.
• Each Ambi-Dry Verge Unit is secured at the head by the verge/batten end clip and
by lugs locating into channels on the top and bottom, along the length of the unit. It
is essential that all three points of contact are engaged.
• When used at a top edge abutment, or similar situation, a lead flashing should be
dressed over the head of the top verge unit. The flashing length will be dependent
on the rafter pitch.
• At the ridge, a Ridge Comb Closer should be used to prevent the ingress of birds
and a Block End Ridge tile should be used.
• Where timber sarking is used over the main roof area, the tiling battens should rest
on the extreme brickwork or cladding (see detail shown). Suitable for 25mm thick
batten only.
• Ambi-Dry Verge units for Cambrian and Stonewold II are fixed by a Verge Clip
included in the pack.
• Ambi-Dry Verge units for Mini Stonewold, MockBond Mini Stonewold, Landmark
Double Pantile, Landmark Double Roman, 50 Double Roman, Grovebury, Regent,
Slate 10, DuoPlain and Renown are fixed by a batten end clip included in the pack.
Ambi-Dry Verge Unit (Plan View)
Features
• Secure fixing system provides high resistance
to wind uplift for both verge tiles and the
Ambi-Dry units
• Ambi-Dry Verge and Slate 10 Dry Verge are
guaranteed weathertight and secure for 15 years
when used with compatible tiles and slates from
the Redland range
• Quick to install and can be laid at various headlaps
• Ambi-Dry verge is adapted on-site to fit either
the left or right hand verge
• Slate 10 Dry Verge is available as dedicated left
and right hand units
• Eliminates the need for an undercloak
• Tried and tested and complies with BS
5534:2003 requirements for mechanical fixing
• Ambi-Dry Verge and Slate 10 Dry Verge are
available in terracotta, brown and grey
(DuoPlain also available in red)
(Cambrian and Stonewold II only available
in grey)
Ambi-Dry Verge System with Vertical Slating (Cambrian)
Ambi-Dry Verge Unit (Internal Elevation)
Compatibility and Performance
Ambi-Dry Batten End Clip | Ambi-Dry Verge Clip
Ambi-Dry Verge - Maximum Pitches
Cambrian
Stonewold II
Mini Stonewold (inc MockBond)
Landmark Double Pantile/Grovebury
Landmark Double Roman/50 Double Roman
Regent
Renown
DuoPlain
Slate 10 Dry Verge
Duo-pitch Roofs
Mono-pitch Roofs
60º
44º
67.5º
67.5º
62.5º
67.5º
60º
60º
55º
67.5º
44º
72.5º
57.5º
67.5º
52.5º
65º
47.5º
45º
Ambi-Dry Verge System (Mini Stonewold)
• There is no maximum pitch on lean-to roofs or where lead roll details are used
• Minimum pitch will depend upon the minimum pitch recommended for the roof tiles
Slate batten finished 60mm
beyond face of wall
230
•
•
Profile
A
B
C
D
E
F
G
Cambrian
Slate 10 Range
Landmark Double Pantile/ Grovebury
Landmark Double Roman/
50 Double Roman
60
72
72
55
20
20
40
60
60
60
85
85
85
150
150
205
225
225
305
390
390
72
20
60
85
150
225
390
Regent
Renown
Stonewold II
Mini Stonewold/MockBond
DuoPlain
72
72
65
72
53
20
20
45
20
25
60
60
80
60
54
85
85
100
85
73
150
150
145
150
115
225
225
305
225
160
390
395
390
390
240
•
•
Components
Each Ambi-Dry Verge System contains:
Ambi-Dry Verge Unit x 10 (uPVC) or for Slate 10 Verge 10 LH or 10 RH unit
Ambi-Dry Verge Clips or batten end clips x 10 (stainless steel)
Each Ambi-Dry Eaves/Ridge Pack consists of:
Eaves Stop End x 1 (uPVC) + Closer Clip (stainless steel)
Ridge Comb x 1 (uPVC) + Closer Clip (stainless steel)
INTERACTIVE SECTION
www.redland.co.uk/verges
Ambi-Dry Verge
231
Dry Hip System
The Dry Hip System has delivered years of trouble free service on tens of thousands
of properties throughout the UK. With very high resistance to storm damage and no
mortar required, concerns about mortar failure can be ignored. The Dry Hip System
also has exceptional durability with a design life exceeding 30 years.
Dry Hip System with Third Round Hip Tile (Grovebury)
Dry Hip System with Universal Angle Hip Tile (Cambrian)
S/S Wood Screw with Neoprene Washer
Rollable weathertight
membrane (grey)
Features
• Provides a neat and attractive finish to the
hip line
• Hip Tiles are secured to the appropriate size hip
batten using stainless steel wood screws, which
give exceptional resistance to wind uplift
• Quick to lay and can be used even when bad
weather is expected
• Tried and tested and complies with BS 5534:2003
requirements for mechanical fixing
• Guaranteed weathertight and secure for 15 years
when used with the Redland range of tiles
and slates
Universal Angle Hip with nail holes
Universal Angle Block-end Hip
Hip Tile Support
Compatibility
• Suitable for use with the Dry and Dry Vent
Ridge Systems
• Not suitable for use with Cathedral Clay Pantile,
Norfolk Pantile, 49 Tile, Rosemary, Heathland and
Old Hollow Clay Pantile
25 x 50mm SW noggins cut
between rafters and nailed
with 50mm galvanised nails
Cambrian Slate cut
to rake of hip
Spirtech 100 or 250
Performance
• Pitch range varies according to plan angle and
tile profile. Please contact Technical Solutions
• Minimum pitch will depend upon the minimum
pitch of the roof tiles
• This system is designed for use where pitches
to either side of the hip are equal*
Guidance Notes
• The Dry Hip System is suitable for traditional timber rafter, timber trussed rafter
and rigid sarking constructions at all pitches and plan angles.
• Dry Hip can be adapted to ventilate the batten cavity when used with Spirtech
underlay. Hip tile support must be fixed to an additional hip batten fixed over the
rollable membrane.
• Care must be taken when using timber sarking that the hip rafter is raised using
timber batten(s) to ensure that the wood screw penetrates the hip batten by a
minimum of 15mm.
• All profiles require a standard 50 x 50mm hip batten, with the exception of
Richmond 10, Saxon 10, MockBond Richmond 10 and Landmark Slate 10 when this
batten is reduced to 50 x 38mm.
• For Cambrian Slate contact Technical Solutions.
• The system should start at the eaves with a Block-end Hip Tile.
• For pitches up to 60º (and plan angle is 90º) where two hips intersect with a Dry or
DryVent Ridge a Hip/Ridge junction should be used.
• For pitches above 60º where the Dry Hip System does not finish at a conventional
ridge intersection with two hips, the Hip/Ridge junction should be completed with a
Rapid Flashing saddle.
• Cambrian Double Slates will be required on all courses on either side of each hip
below 25º. At pitches greater than this Cambrian Slate-and-a-halves can be used.
• For number of spacer blocks and maximum centres required see fixing instructions.
• For use with unequal pitches please contact Technical Solutions.
• For DuoPlain use standard tiles and tile and a half adjacent to the hip to avoid small
pieces of cut tile.
•
234
226
•
305
450
•
•
•
•
•
31
67
Universal Angle Hip Tile
233
Components
Each Dry Hip Pack contains sufficient components to secure 2.7 metres of concrete
Hip Tiles.
Each pack contains:
• Rafter Nails (stainless steel)
Rollable weathertight membrane
• Hip Batten Nails (stainless steel) In
(grey) – 280mm x 2.75m
addition, concrete Hip Tiles with nail
Hip Tile Supports
holes will be required in a colour to
(Polypropylene – black)
suit, with matching Block-end Hip
Hip Batten Straps (stainless steel)
Tiles at the eaves.
Spacer Blocks (PVC – black)
• A 50 x 50mm or 50 x 38mm hip
Head Clips (stainless steel)
batten must be fixed
Tail Clips (aluminium)
100mm Wood Screws (stainless steel)
237
445
INTERACTIVE SECTION
450
70
* Where the roof pitches are uneven please contact Technical Solutions
232
Third Round Hip Tile
Hip Tile Support
Hip/Ridge Junction
(Sold Separately)
www.redland.co.uk/dryhip
Dry Hip System
233
Rapid Hip System
The Rapid Hip System is an easy and quick-to-fit, maintenance-free hip system with
very high resistance to storm damage. With no mortar required it removes concerns
about mortar failure. The system also ventilates the batten cavity when used with
Spirtech underlay.
Features
• Hips are up to a third quicker to complete than
when mortar bedded
• Hip Tiles are secured to the appropriate size hip
batten using stainless steel woodscrews, which
give exceptional resistance to wind uplift
• Provides a neat and attractive finish to the hip line
• Easy to install and can be used even when bad
weather is expected
• Ventilates the batten cavity to comply with
BS 5250 :2011, therefore reducing the risk of
harmful condensation in the roof (when used
with Spirtech Vapour Permeable Underlay)
• Tried and tested and complies with BS
5534:2003 requirements for mechanical fixing
• Guaranteed weathertight and secure for 10/15
years (depending upon project) when used with
the Redland range of tiles and slates
range
• Rapid Hip is part of the
of components
Compatibility
• Suitable for use with the Rapid Vented
Ridge and Uni-Vent Rapid Ridge
• Suitable for use with the Redland range of tiles
and slates
Rapid Hip System with Third Round Hip Tile (Grovebury)
S/S Woodscrew with Neoprene Washer
Hip Tile Support
Rollable membrane
S/S Hip Batten Fixing Strap nailed to hip rafter
and hip batten with S/S Ring Shank Nails
50 x 50mm S.W. hip batten
S/S Wood Screw with Neoprene Washer
Third Round Hip with nail holes
Third Round Block-end Hip
S.W. counterbatten min. 38mm
wide abutting spacer batten
Grovebury Tile cut to
rake of hip and
mechanically fixed
Rollable weathertight
membrane (grey)
Hip Batten Spacing Blocks
S.W. spacer batten fixed to hip
rafter to a height level with
top of counterbattens
Spirtech 100 or 250 underlay
to overlap on adjacent slope
by a min.150mm
Aluminium Tail Clips
Insulation board
Performance
• Pitch range varies according to plan angle and
tile profile. Please contact Technical Solutions
• Minimum pitch will depend upon the minimum
pitch of the roof tiles.
• This system is designed for use where pitches to
either side of the hip are equal*
Rapid Hip System with Universal Angle Hip Tile (Cambrian)
Universal Angle Hip with nail holes
Universal Angle Block-end Hip
Hip Tile Support Tray
Cambrian Slate cut to rake
of hip and mechanically fixed
25 x 50mm SW noggins cut
between rafters and nailed
with 50mm galvanised nails
Spirtech 100 or 250
Hip rafter
235
226
•
•
•
•
•
•
•
•
•
•
305
450
67
233
237
2700
Universal Angle Hip Tile
Guidance Notes
• The Rapid Hip System is suitable for traditional timber rafter, timber trussed rafter
and rigid sarking constructions at all pitches and plan angles. Rapid Hip ventilates the
batten cavity when used with Spirtech underlay.
• Care must be taken when using timber sarking that the hip rafter is raised using timber
batten(s) to ensure that the wood screw penetrates the hip batten by a minimum of
15mm.
• All profiles require a standard 50 x 50mm hip batten, with the exception of
Richmond 10, Saxon 10, MockBond Richmond 10 and Landmark Slate 10 when this
batten is reduced to 50 x 38mm for pitches up to 40º and 50 x 25mm above 40º.
(Use a 50 x 38mm hip batten for Cambrian Slates above 25º).
• Ensure that the tile overhang at each eaves is the same.
• The system should start at the eaves with a Block-end Hip Tile.
• For pitches up to 60º (and plan angle is 90º) where two hips intersect with a ridge,
Hip/Ridge Junction should be used.
• For pitches above 60º, plan angle other than 90º or where the Rapid Hip System does
not finish at a conventional ridge intersection with two hips, the Hip/Ridge junction
should be completed with a Rapid Flashing saddle.
• Cambrian Double Slates will be required on all courses on either side of each hip
below 25º. At pitches greater than this Cambrian Slate-and-a-halves can be used.
• For number of spacer blocks and maximum centres required see fixing instructions.
• Where pitches are unequal, please contact Technical Solutions.
• For DuoPlain use tile and a half on each course either side of the hip to avoid small
pieces of cut tile.
Components
Each Rapid Hip Pack contains sufficient components to secure 5 metres of concrete Hip Tiles
Rollable weathertight membrane (grey) – 280mm x 5m
GRP Hip Tile Support Tray (grey)
Hip Batten Straps (stainless steel)
Spacer Blocks (PVC – black)
Head Clips (stainless steel)
Tail Clips (aluminium)
100mm Woodscrews (stainless steel)
Rafter Nails (stainless steel)
Hip Batten Nails (stainless steel)
INTERACTIVE SECTION
450
70
* Where the roof pitches are uneven please contact Technical Solutions
234
Third Round Hip Tile
GRP Hip Tile support Tray
Hip/Ridge Junction
(sold separately)
www.redland.co.uk/rapidhip
Rapid Hip
235
Cambrian Mitred Hip System
Specifically designed for use with Cambrian Slates to achieve a neat mitred hip detail,
whilst ensuring very high resistance to storm damage over a wide range of rafter
pitches and plan angles.
Features
• Provides a neat and attractive finish to the hip line
• Easy to install and can be used even when bad weather is expected
• Tried and tested and complies with BS 5534:2003 requirements for mechanical fixing
• Guaranteed weathertight and secure for 15 years with Cambrian Slates
Performance
• At 90° plan angle, the minimum pitch is 15° and the maximum pitch is 80°. For other plan angles,
refer to the table adjacent
Plan Angle Against Roof Pitch Showing Approved Usage
Cambrian Mitred Hip System
Roof Plan Angle (degrees)
Roof Pitch (degrees)
90
95
15
•
-
17.5
•
•
20
•
•
22.5
•
•
25
•
27.5
100
Stainless Steel Screw and Clip
105
110
115
120
125
130
135
140
145
150
155
-
-
-
-
-
-
-
-
-
-
-
-
•
•
-
-
-
-
-
-
-
-
-
-
•
•
•
•
-
-
-
-
-
-
-
-
•
•
•
•
•
-
-
-
-
-
-
-
•
•
•
•
•
•
•
-
-
-
-
-
-
•
•
•
•
•
•
•
•
•
-
-
-
-
-
30
•
•
•
•
•
•
•
•
•
•
-
-
-
-
32.5
•
•
•
•
•
•
•
•
•
•
•
-
-
-
35
•
•
•
•
•
•
•
•
•
•
•
-
-
-
37.5
•
•
•
•
•
•
•
•
•
•
•
•
-
-
40
•
•
•
•
•
•
•
•
•
•
•
•
-
-
42.5
•
•
•
•
•
•
•
•
•
•
•
•
-
-
45
•
•
•
•
•
•
•
•
•
•
•
•
•
-
47.5
•
•
•
•
•
•
•
•
•
•
•
•
•
-
50
•
•
•
•
•
•
•
•
•
•
•
•
•
-
52.5
•
•
•
•
•
•
•
•
•
•
•
•
•
-
55
•
•
•
•
•
•
•
•
•
•
•
•
•
-
57.5
•
•
•
•
•
•
•
•
•
•
•
•
•
-
60
•
•
•
•
•
•
•
•
•
•
•
•
•
•
62.5
•
•
•
•
•
•
•
•
•
•
•
•
•
•
65
•
•
•
•
•
•
•
•
•
•
•
•
•
•
67.5
•
•
•
•
•
•
•
•
•
•
•
•
•
•
70
•
•
•
•
•
•
•
•
•
•
•
•
•
•
72.5
•
•
•
•
•
•
•
•
•
•
•
•
•
•
75
•
•
•
•
•
•
•
•
•
•
•
•
•
•
77.5
•
•
•
•
•
•
•
•
•
•
•
•
•
•
80
•
•
•
•
•
•
•
•
•
•
•
•
•
•
82.5
-
•
•
•
•
•
•
•
•
•
•
•
•
•
85
-
•
•
•
•
•
•
•
•
•
•
•
•
•
87.5
-
•
•
•
•
•
•
•
•
•
•
•
•
•
90
-
•
•
•
•
•
•
•
•
•
•
•
•
•
Cambrian Double Slate or
Slate-and-a-half cut to rake of hip,
see guidance notes
Cambrian Mitred Hip
Weathering Unit
Spirtech 100 or 250
Trussed rafter
Components
The Cambrian Mitred Hip System contains sufficient components in each
pack for ten courses of slates.
Each pack contains:
• Hip Weathering Units (Polypropylene – grey).
• Tail Clips and Screws (stainless steel).
INTERACTIVE SECTION
490
27
255
450
300
12
140
312
312
Weathering Unit
236
Guidance Notes
• The Cambrian Mitred Hip System is suitable for traditional timber rafter, timber
trussed rafter and rigid sarking constructions.
• Suitable for hips with an equal pitch on both slopes.
• Care must be taken when using timber sarking that the hip rafter is raised using
timber batten(s) to ensure that the wood screw penetrates the hip batten by a
minimum of 15mm.
• Cambrian Double Slates will be required on all courses on either side of each hip
below 45º pitch. At pitches of 45º and above, Cambrian Slate-and-a-Halves can
be used. At pitches of 45º and below use a double slate for the top course at the
ridge/hip junction.
• At the junction between two mitred hips and a Universal Angle duo ridge, a
Cambrian Mitred Hip Block-end Ridge (product code 7211) should be used.
• Where a hip starts or finishes at a position other than a duo ridge or eaves, a lead
or Rapid Flashing saddle will be required.
600
Clip
Cambrian Mitred Hip Block-end Ridge
Cambrian Double Slate
www.redland.co.uk/mitredhip
Cambrian Mitred Hip
237
125 GRP Valley
Cambrian GRP Valley
Designed as a cost effective alternative to lead, the 125 GRP Valley is easy to fix,
durable and lightweight. It is ideal for most types of roof design which have a junction
between two roof slopes.
The Cambrian GRP Valley is a cost effective, dry-fix valley which does not require
any mortar. An alternative to lead, the Cambrian GRP Valley offers a combination of
exceptional ease of fixing with an extremely durable and lightweight design.
Features
• Easily cut and available in 3 metre lengths
• Tried and tested and complies with
BS 5534:2003 requirements for valleys
• Fire tested to BS 476-3:2004
• Guaranteed weathertight and secure for 10/15
years (depending upon project) when used with the
Redland range of tiles and slates
• 125 GRP Valley is part of the
range
of components
Features
• The only GRP Valley compatible with
Cambrian Slates
• Easily cut and available in 3 metre lengths
• Tried and tested and complies with
BS 5534:2003 requirements for valleys
• Fire tested to BS 476-3:2004
• Guaranteed weathertight and secure for 15
years when used with Cambrian Slates
Compatibility
• Suitable for all of the Redland range of tiles and
slates except Cambrian Slates (for Cambrian see
the Cambrian GRP Valley on the next page)
Cement: sand mortar (to comply to tensile
bond strength in BS 5534) bedding
the continuous valley length onto
GRP sanded strip
www.redland.co.uk/valleys
125 GRP Valley
238
Performance
• Minimum pitch 17.5° at 90° plan angle
• Maximum pitch 45° at 90° plan angle
• For pitch range at plan angles other than 90°
please contact Technical Solutions
• Width of valley gutter 125mm
• Where roof plan area discharging into the valley
is greater than 25m2, minimum rafter pitch is 30°
• Valley can accommodate a 5° pitch variance
between slopes
125 GRP Valley
125mm width between vertical
faces of valley
Norfolk Pantile cut to rake of
valley and mechanically fixed
INTERACTIVE SECTION
• A specific version of this valley is available for
Natural Slate
125 GRP Valley nailed to
25mm thick S.W valley battens
250mm x 19mm valley
support board cut between
trussed rafters and
supported on
25mm thick noggins nailed to rafters. Top surface
of support board must be flush with top of trussed rafters
Spirtech 100 or 250 underlay
turned up onto S.W. support batten
S.W. batten supported on
edge of valley support board
Trussed
rafters
Guidance Notes
• Lay the 125 GRP Valley on timber support boards, laid between rafters
on noggins.
• At ridge/valley intersections, a lead saddle is required, alternatively Rapid
Flashing can be used.
• At the eaves, cut the 125 GRP Valley to a ‘V’ to allow water to flow into
gutters. The fascia board will require cutting to suit.
• Where the valley discharges onto tiling, a lead flashing is required.
• Vapour permeable underlay can be laid either under the 125 GRP Valley or up
to the edge of the valley support batten
Components
• Supplied in 3 metre lengths (grey glass reinforced polyester).
125mm width between vertical faces of valley
Performance
• Minimum pitch 17.5° at 90° plan angle
• Maximum pitch 45° at 90° plan angle
• For pitch range at plan angles other than 90°
please contact Technical Solutions
• Width of valley gutter 125mm
• Where roof plan area discharging into the valley
is greater than 25m2, minimum rafter pitch is 30°
• Valley can accommodate a 5° pitch variance
between roof slopes
S/S Cambrian Verge Clip
Cambrian Slate-and-a-half or
Double Slate cut to rake of valley
S.W. batten supported on
edge of valley support board
Spirtech 100 or 250 underlay
turned up face of batten
250mm x 19mm valley support board cut between
trussed rafters and supported on 25mm thick noggins nailed to rafters.
Top surface of support board must be flush with top of trussed rafters
Cambrian GRP Valley
nailed to 25mm thick
S.W. valley batten
Trussed rafters
Cambrian GRP Valley
Guidance Notes
• Lay the Cambrian GRP Valley on timber support boards, laid between rafters
on noggins.
• At ridge/valley intersections, a lead saddle is required, alternatively Rapid
Flashing can be used.
• At the eaves, cut the Cambrian GRP Valley to a ‘V’ to allow water to flow into
gutters. The fascia board will require cutting to suit.
• Where the valley discharges onto tiling, a lead flashing is required.
• Cambrian Double Slates will be required on all courses on both sides of the
valley below 25°. At pitches of 25° and above, Cambrian Slate-and-a-halves
can be used.
• Vapour permeable underlay can be laid either under the Cambrian GRP Valley
or up to the edge of the valley support batten
Components
• Supplied in 3 metre lengths (grey glass reinforced polyester).
INTERACTIVE SECTION
www.redland.co.uk/valleys
125 GRP Valley
239
Side Abutment GRP Secret Gutter
Top Edge Abutment Ventilation System
The Side Abutment GRP Secret Gutter offers a secondary line of defence against wind
driven rain where a roof slope abuts a vertical wall. Being easy to cut and install makes
this product an idea solution for these otherwise complicated details.
The Top Edge Abutment Ventilation System provides a continuous, unobtrusive, ventilation
path from the roof void to the outside.The innovative design enables the system and
cover flashing to be installed far quicker than when traditional methods are used.
Features
• Lightweight, easy to handle 3 metre lengths
• Tried and tested and complies with BS 5534:2003
• Fire tested to BS 476-3:2004
• Guaranteed weathertight and secure for 15 years
when used with the Redland range of slates
and DuoPlain
Features
• Ventilates to comply with BS 5250 :2011,
therefore reducing the risk of harmful
condensation in the roof
• Tried and tested and complies with
BS 5534:2003 requirements for mechanical fixing
• Guaranteed weathertight and secure for 15
years when used with the Redland range of tiles
and slates
Compatibility
• Suitable for all interlocking slates in the Redland
range and DuoPlain
• For Cambrian use Standard Slates and Slate-anda-Halves on alternate courses
• For all other slates use Standard Slates with
interlock removed and Left-hand Half Slates
alternately on left-hand abutments. Use Standard
Slates and Right-hand Half Slates alternately on
right-hand abutments
• For DuoPlain use Standard Tiles with interlock
removed and LH 3/4 Tiles alternatively on LH
abutments. Use Standard Tiles and RH 3/4 tiles
alternatively on RH abutments
• Gutter Overlap:
150mm overlap for rafter pitch 30º and above.
200mm overlap for rafter pitch 22.5º - 29.5º.
250mm overlap for rafter pitch 17.5º - 22º.
300mm overlap for rafter pitch 15º - 17º.
Performance
• Minimum pitch 15°
• Maximum pitch 90°
Abutment GRP Secret Gutter
Cavity tray
Rapid Flashing step and cover flashing turned into
brickwork under cavity tray by a min. 25mm.
Dress over slate by not less than 150mm
Saxon 10 Slate. Must be mechanically fixed
INTERACTIVE SECTION
65mm
min.
50mm
www.redland.co.uk/secretgutter
Side Abutment GRP Secret Gutter
240
Spirtech 100 or 250 underlay
turned up wall by 50mm
Abutment GRP Secret Gutter
Trussed rafter
Guidance Notes
• Fix a timber tilting fillet to support a lead secret gutter outlet at base of
secret gutter. Lead gutter outlet should be splayed out to ensure that water
is discharged into gutter at eaves or out over tiles immediately below side
abutment. For a lead free alternative consider using Rapid Flashing.
• Finish underlay against wall.
• Finish tiling battens 55mm from wall and nail to final rafter.
• Mechanically fix all slates adjacent to the abutment.
• Where final rafter is less than 50mm from the wall, nail a 50 x 50mm batten
to the side and flush with the top of the rafter to support ends of the
tiling battens.
Components
• Supplied in 3 metre lengths (glass reinforced polyester).
Performance
• Minimum pitch will depend upon the minimum
pitch of the roof tiles but must not be less than 15°
• Maximum pitch 60° (Stonewold II 44º)
• The effective ventilation area per metre run of
abutment is 5,000mm²
13
90
10 36 10
64
15
5
Lead Support Tray (PVC – grey)
Compatibility
• Available for all tiles and slates in the Redland
range except Cathedral Clay Pantile, 49 Tile and
Old Hollow Pantile
• For Natural Slate contact Technical Solutions
50
Spacer Block
76
21
17
22
10
22
64
6
Rachet Clip (uPVC-Grey)
For Profile Filler Unit and dimensions refer to p. 244 Dry Ridge System.
Top Edge Abutment Ventilation System
Guidance Notes
• Ensure that the air passage from the roof void is not obstructed.
• The Abutment Ventilation System is suitable for both traditional timber rafter
construction, timber trussed rafter and rigid sarking constructions.
• The system is designed to fit a straight and level abutment wall.
• Full fixing instructions are included with each pack.
• The cover flashing can be either lead or Rapid Flashing; neither are supplied in
the pack.
• If using Rapid Flashing in an exposed location please contact Technical Solutions.
• If using lead, side laps should be a minimum of 150mm and a maximum sheet
length of 1.5m.
• Mechanically fix all tiles on the top course.
INTERACTIVE SECTION
www.redland.co.uk/topedge
Top Edge Abutment Ventilation
241
Rapid Flashing
Rapid Roof Vents
Rapid Flashing can be used instead of lead for the majority of pitched roof applications.
The unrivalled speed and ease of installation enables standard flashing details to be
completed twice as quickly as with lead, offering a viable and safer alternative to
traditional methods.
Features
• Lighter weight than lead and easy to use
• Can be moulded quickly and easily, without the
need for special tools
• Manufactured from environmentally-friendly
materials
• No welding required, thanks to the self-fusing
properties of the material
• Insensitive to extremes of cold and heat
(-40º to +100ºC)
• UV resistant
• Guaranteed weathertight and secure for 10 or
15 years depending on project, when used in
conjunction with the Redland range of tiles
and slates
Cavity tray
Rapid Flashing step and cover flashing turned into
brickwork under cavity tray by a min. 25mm.
Dress over slate by not less than 150mm
Saxon 10 Slate. Must be mechanically fixed
INTERACTIVE SECTION
65mm
min.
50mm
www.redland.co.uk/rapidflashing
Rapid Flashing
242
Spirtech 100 or 250 underlay
turned up wall by 50mm
Abutment GRP Secret Gutter
Trussed rafter
range
• Rapid Flashing is part of the
of components
Compatibility
• Compatible with all Redland tiles and slates
Performance
• Suitable for all pitches and plan angles
• Awarded British Board of Agrément Certification,
certificate number 09/4622
A range of in-line ventilating tiles suitable for both low and high-level roof space
ventilation, to combat condensation, as well as mechanical and soil pipe ventilation.
Suitable for use with most popular interlocking concrete tiles and plain tiles.
Features
• Looks like a standard roof tile
• Raised nail holes (for improved weather
performance)
• Integral design shaped to divert water around the
grille, maximum 4mm gap to prevent insect entry
• Single bead side lock with increased water capacity
• Water drain to allow any water to drain out onto the
tile below
Performance
• 10,000mm² ventilation on metric tile vents with
low air flow resistance
• Excellent weather performance
• Rigid construction, high quality
• Long life due to UV stable PVC upper tray
• Underlay seal for improved fit and controlled
ventilation
• Inner baffles prevent water entering the air path,
endorsed by wind tunnel tests
• Rapid Roof Vents are backed by Redland's
10 year HomeSpec and HouseBuilder Guarantees.
• Rapid Roof Vents are part of the
range of components
Compatibility
• Complies with NHBC guidelines for high-level
ventilation in new build housing
• In-line design matches the aesthetics of the roof
• Suitable for Renown, Double Roman, Grovebury,
Mini Stonewold, Redland 49 and concrete Plain
Tiles in a range of colours.
Rapid Flashing
Guidance Notes
• Must be installed on dry and
clean tiles.
• Rapid Flashing must be inserted
into the mortar joint of brickwork
as per traditional practice.
• Clips must be inserted to secure
Rapid Flashing to the mortar joint
and then sealed with a
suitable sealant.
• A Side abutment secret gutter
must be used with all interlocking
flat tiles.
Components
Colourfast plastic with aluminium
rib mesh insert and butyl sealing edge
Available in
180mm x 5m
280mm x 5m
280mm x 10m
370mm x 5m
560mm x 5m
Lead Grey Black
•
•
•
•
•
•
•
•
-
423
385
330
334
230
330
Guidance Notes
• Place the vent tile in position so that the moulded underside clip is located
below the interlock of the adjacent tile (when fitted this prevents the vent tile
from lifting).
• Ensure the underlay seal fits around the spigot and returns to a flat position
against the underlay after fitting.
• When using the adaptor, ensure the adaptor lugs are located in the
appropriate channels in the vent spigot.
• Rapid Roof Vent for Redland 49 tiles must be installed with the adaptor pipe
supplied.
INTERACTIVE SECTION
Components
• 1 x Vent. • 1 x Underlay Seal. • 1 x Pipe Adaptor (49 Tile Vent only).
100
65
113
www.redland.co.uk/rapidroofvents
Rapid Roof Vents
243
Dry & DryVent Ridge System
The DryVent Ridge System provides a continuous weathertight ventilation path from
the roof void to the outside. The system can also be easily converted when no high
level ventilation is required at the ridge. Both solutions provide an exceptionally
durable method of securing ridge tiles. They are maintenance free and require no
mortar, delivering high resistance to storm damage.
DryVent Ridge System (Cambrian)
S/S Clamping Plate
S.W. ridge batten 38mm wide.
For height refer to table below
Polypropylene Ridge to Ridge Seal
DryVent Ridge System with Traditional Ridge Tree (Plain Tile)
S/S Ridge Batten Fixing Strap fixed to
each rafter with S/S Ring Shank Nails
Universal Angle Ridge
Compatibility
• Available for all tiles and slates in the Redland
range except Cathedral Clay Pantile, 49 Tile and
Old Hollow Pantile
• Suitable for use with concrete Half Round and
Universal Angle Ridge Tiles and Rosemary Clay
Half Round Ridge Tiles (300mm)
Height of ridge batten taken from
Ridge Batten Height Table and then
reduced by dimension x to allow for
the height of the ridge tree
Spirtech 100 or 250
uPVC Profile Filler Unit
Spirtech 100 or 250 underlay
left short of apex to allow
for ventilation
Cambrian Slate
Features
• Provides a neat and attractive finish to the
ridge line
• Easy to install and can be used even when bad
weather is expected
• Ventilates and complies with BS 5250 :2011,
therefore reducing the risk of harmful
condensation in the roof
• Tried and tested and complies with BS
5534:2003 requirements for mechanical fixing
• Guaranteed weathertight and secure for 15 years
when used with the Redland range of tiles
and slates
T imber ridge tree
S/S WoodScrew with Neoprene
Washer and Foam Grommet
x see guidance
notes
Pitch Range and Ridge Batten Height for Dry & DryVent Ridge System (38mm wide ridge batten)
Roof Pitch (degrees)
Landmark Double Pantile, Grovebury
Landmark Double Roman/50 Double Roman
Regent
Renown
Norfolk Pantile
Natural Slate#
Cambrian
Slate10 Range
Stonewold II
Mini Stonewold
DuoPlain
Plain Tile, Heathland
Performance
• For minimum and maximum pitches, refer to the
table on the next page
• Must not be used below 15°
12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70
-
100
100
50
-
100
75
100
75
100
50
50
75
75
-
75
75
100
75
100
50
50
50
50
-
75
75
75
50
75
50
50
50
50
-
75
75
75
50
75
50
50
50
50
-
75
75
75
50
75
25
25
50
50
50
50
-
75
50
75
50
75
25
25
25
50
50
50
-
75
50
75
50
75
25
25
25
50
50
50
-
50
50
75
50
75
25
25
25
25
25
25
50
50
50
50
25
50
25
25
25
25
25
25
25
50
50
50
25
50
25
25
25
25
25
25
25
50
25
50
25
50
25
25
25
25
25
25
25
50
25
50
25
50
25
25
25
25*
25
25
25
50
25
50
25
50
25
25
25
25
25
25
-
50
-
50
75
75
75
-
50
50
75
75
-
50
50
50
75
-
25
50
50
50
50
-
25
25
50
50
50
-
25
25
25
50
50
-
25
25
50
50
50
-
25
25
25
25
25
50
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25*
25
25
25 25 25 25 25 25 25 25 25 25 25 25 25
-
- 75 50 50 50 50
75 75 75 75 75 75 50 50 50
- 100 75 75 75 75 75 75 50
- 75
50
50
50
75
25
25
50
75
25
25
50
50
25
25
50
50
25
25
25
50
50
25
50
25
50
25
25
25
25
25
25
50 25 20 25 20 25 25 25 25 25 25 25 25 25 25 25 25 25
-
-
-
-
-
-
Guidance Notes
• Dry & DryVent Ridge is suitable for traditional timber rafter, timber trussed rafter and
rigid sarking constructions. The system is designed to fit a straight and level ridge line.
• When used with traditional timber rafters, the height of the ridge board above the
apex of the rafters (x) will alter the number of 38mm x 25mm tile battens required
to construct the ridge tree. This ensures that the ridge tile securing screw achieves a
minimum 15mm of penetration (see detail shown).
• Where timber sarking is used with DryVent Ridge, sarking and underlay are left short
of apex to allow 10mm air gap. Counterbattens are extended to form an apex to
support the ridge tree batten.
• Special DryVent Ridge Packs (9085) are required when using Ornamental Universal
Angle Ridge Tiles. Batten heights remain as given in the table below.
• Where Gas Flue Ridge Terminals are used with DryVent Ridge refer to guidance notes
on page 255.
• If this system is to be used with natural/fibre cement slates or unequal pitches, please
contact our Technical Solutions Hotline.
• Counterbattens/rafters on adjacent roof slopes must be aligned.
• Detailing may vary for different profiles. Please refer to the fixing instructions.
• When no high level ventilation is desired, the underlay is taken over the apex of the
ridge, as in a mortar bedded detail.
• Finish ridge ends with mortar or Block End Ridge tile.
• Mechanically fix all tiles in the top course.
• Rosemary Eave/Top Tile does not hang on the final plain tile course as for concrete
plain tiles. Instead the Eave/Top Tile must be twice nailed to an additional batten that
is turned on its side. Top and second top batten positions from apex are 35mm and
75mm respectively.
• A 38mm wide timber ridge batten must be fixed, the height of which will depend
upon the profile of the tiles and the pitch of the roof (see table).
Universal Angle
38
256
244
246
300
51
128
Half Round Ridge Tile
(clay)
Profile Filler Unit
25
24
50
K
25
J
Batten Strap
58
21
Profile Filler Unit
(Grovebury shown)
10
Ridge to Ridge Seal
(Half Round concrete shown)
Clamping Plate
Flat Tiles/Slates
Landmark Double Pantile
Landmark Double Roman
Regent
Grovebury
50 Double Roman
Renown
Norfolk Pantile
J
K
21
59
47
59
59
47
40
61
450
298
298
298
298
298
298
198
Natural Slate#
Cambrian
Slate 10 Range
Stonewold II
Mini Stonewold
Plain Tile
-
-
Rosemary Half Round
Natural Slate#
Cambrian
Slate10 Range
Rosemary Clay Plain Tile
25
25
25
50
25
25
25
50
INTERACTIVE SECTION
25 25 25 25 25 25 25 25 25 25 25 25 25 25
* 44º maximum pitch # 500 x 250 Standard Pre-holed at 190mm from head. Pitch range depends upon exposure level. Note: For Top Batten Distance from Apex please refer to the relevant product Fitting Instructions.
For pitches outside the above range please contact Technical solutions. Pitches between those shown use the taller ridge batten height figure.
www.redland.co.uk/dryventridge
Dry & Dryvent Ridge System
245
Uni-Vent Rapid Ridge & Rapid Vented Ridge Systems
The Rapid Vented Ridge System provides both high-level ventilation and mechanically
fixed ridge tiles. The system is a genuine alternative to a mortar bedded ridge with
the added advantage of being quicker and requiring less skill to install. The
Range also includes Uni-Vent Rapid Ridge, which is a cost effective dry-fix system.
The illustration shows Rapid Vented Ridge ventilating the roof void.
Features
• The Rapid Vented Ridge System uses
ridge-to-ridge seals that match the profile of
the Redland ridge tiles perfectly to give a
guaranteed weathertight seal
• Uni-Vent Rapid Ridge System uses a flexible
ridge-to-ridge seal to enable use with both Half
Round and Universal Angle concrete ridge tiles
• Traditional appearance
• Up to 33% quicker to fit than a mortar
bedded ridge
• Easy to install and can be laid even when bad
weather is expected
• Uni-Vent Rapid Ridge and Rapid Vented Ridge
Systems ventilate and comply with BS 5250:2011,
therefore reducing the risk of harmful condensation
in the roof void
• Tried and tested and complies with BS 5534:2003
requirements for mechanical fixing
• Rapid Vented Ridge guaranteed weathertight and
secure for 15 years when used with the Redland
range of tiles and slates
• Uni-Vent Rapid Ridge guaranteed weathertight
and secure for 10 years as part of the HomeSpec
and HouseBuilder Guarantees
Performance
• For minimum and maximum pitches, refer to the
table on the next page
Compatibility
• Uni-Vent Rapid Ridge and Rapid Vented Ridge
Systems are compatible with Natural Slate,
Concrete Slates, profile tiles and Plain tiles
• Uni-Vent Rapid Ridge and Rapid Vented Ridge
Systems are not compatible with Old Hollow,
Clay Half Round Ridge or Ridge Vent Terminals
• Uni-Vent Rapid Ridge is not compatible with
Cathedral tiles
• For Rosemary Clay tiles please contact
Technical Solutions
• Uni-Vent Rapid Ridge is part of the
range of components
• Not compatible with Gas Flue Terminals or
Ornamental Ridge
58
54
Rapid Vented Ridge System (Mini Stonewold)
51
S/S Woodscrew with Neoprene
Washer and Foam Grommet
S.W. ridge battens 38mm wide.
For height refer to table below
S/S Clamping Plate
10
12
S/S Ridge Batten Fixing Strap nailed to
each rafter with S/S Ring Shank Nails
65
Polypropylene Ridge to Ridge Seal
246
253
253
Spirtech 100 or 250 underlay
left short of apex to allow
ventilation
Universal Angle Ridge
Rollable weathertight
membrane
Half Round
Ridge Seal
Universal Angle
Ridge Seal
Mini Stonewold Slate.
Must be mechanically fixed
Uni-Vent Rapid
Ridge Seal
Pitch Range and Ridge Batten Height for Uni-Vent Rapid Ridge and Rapid Vented Ridge System (38mm wide ridge batten)
Roof Pitch (degrees)
12.5
15
17.5
27.5
30
32.5
Half Round
Landmark Double Pantile, Grovebury
Landmark Double Roman
50 Double Roman
Regent
Renown
Norfolk Pantile
49 Tile
Cathedral Clay Pantile
Cambrian
Slate 10 Range
Stonewold II
Mini Stonewold
Plain Tile
DuoPlain
Natural Slate#
100
-
75
75
50
-
75
75
75
75
75
75
75
75
50
50
75
75
75
50
50
75
75
75
75
75
75
50
50
50
50
75
75
75
75
75
50
50
50
50
50
75
75
75
50 25/50 25/50 25
25
50
50
50
50/75 50
50
50
50
50/75 50
50
50
50
50
50
- 25/50 25/50
75
50
50
75
50
75
50
75
25
50
50
25
50
25
75
50
50
75
50
75
50
75
25
50
50
25
50
25
Universal Angle
Cambrian
Slate 10 Range
Stonewold II
Mini Stonewold
Plain Tile
Natural Slate#
20
22.5
25
35
37.5
40
42.5
45
550 50
50
50
50
50
50
50
50
50
50
50
50
50
50
75
75
50
50
50
50
50
50
50
25
75
75
75
50
50
50
50
25
25
25
75
50
50
20
50
25
25
25 25** 25
50
50
25
25
25
25
25
25
25 25*
25
25
25
25
25
25
25
25
25
25
50 25/50 25/50 25
25
25
25 25** 25
25
47.5
50
52.5
55
57.5
50
50
50
50
25
50
25
50
25
25
25
25
-
50
25
25
25
25
50
25**
25**
25
25**
-
50
25
25
25
25
25
25
25
25
-
50
25
25
25**
25
-
25
-
•
•
•
•
•
Components for Rapid Vented Ridge Systems
Each pack contains sufficient components to secure a 5 metre ridge line.
5 metres of rollable membrane.
11 ridge to ridge seals with stainless steel woodscrews and clamp plates.
9 stainless steel ridge batten straps with 18 stainless steel ring shank nails.
2 stainless steel end ridge fixings. (Not included in Uni-Vent Rapid Ridge).
•
•
•
•
•
Components for Uni-Vent Rapid Ridge
Each pack contains sufficient components to secure a 10 metre ridge line.
10 metres of DryRoll membrane.
22 ridge to ridge seals with stainless steel woodscrews and clamp plates.
17 stainless steel ridge batten straps with 34 stainless steel ring shank nails.
2 stainless steel end ridge fixings.
INTERACTIVE SECTION
-
50
-
50
50
50/75 50/75
50
50
-
50
50
50
50
-
50
25
50
50
50
50
50
50
25/50 25/50
25
50
50
50
25
25
50
50
25
25
25
50
25
25
50
25
25 25** 25
25
50
25 25** 25
25
25
25 25*
25
25
25 25**
25
25
25
25
25** 25
25
-
-25
25
25
-
25
25
25
-
25
25**
-
25
-
25
-
* 44° Maximum Pitch ** Maximum Pitch for Uni-Vent Rapid Ridge (Non-Vented) Pitches between those shown use taller Ridge Batten Height - For Top Batten distance from Apex please refer to the relevant product Fitting
Instructions. Uni-Vent Rapid/Rapid Vented (where different) indicated thus 50 / 75 - # 500 x 250mm Standard Pre-Holed at 195mm from head. Pitch range depends upon exposure level.
For pitches outside above range please contact Technical Solutions
246
Guidance Notes
• The Uni-Vent Rapid Ridge and Rapid Vented Ridge Systems are suitable for
traditional timber rafter, timber trussed rafter and rigid sarking constructions. The
systems are designed to fit a straight and level ridge line.
• When used with traditional timber rafters, the height of the ridge board above the
apex of the rafters will alter the number of 38mm x 25mm tile battens required to
construct the ridge tree. This ensures that the ridge tile securing screw achieves a
minimum 15mm penetration.
• Where timber sarking is used sarking and underlay are left short of apex to allow
10mm air gap. Counterbattens are extended to form an apex to support the ridge
tree batten.
• Counterbattens/rafters on adjacent roof slopes must be aligned and extended to
form an apex.
• Ridge Ventilation Terminals are not suitable with Uni-Vent Rapid Ridge or Rapid
Vented Ridge Systems.
• End ridges can be finished with a mortar bedded end or a Block-end Ridge Tile.
• For use with unequal pitches please contact Technical Solutions.
• For use with Natural Slate please contact Technical Solutions.
• Mechanically fix all tiles on the top course.
www.redland.co.uk/univentridge
www.redland.co.uk/rapidridge
Uni-Vent Rapid Ridge & Rapid Vented Ridge
247
Ridge Ventilation Terminal
The Ridge Ventilation Terminal can be used for soil pipe, roof space ventilation or
mechanical extraction. It can be incorporated into a dry or mortar bedded ridge.
Features
• Ventilates to comply with BS 5250:2011,
therefore reducing the risk of harmful
condensation in the roof
• Tried and tested and complies with BS
5534:2003 requirements for mechanical fixing
• Complies with BS EN 490:2011 and BS EN
12056-2:2000
• Guaranteed weathertight and secure for 15
years when used with the Redland range of tiles
and slates
Compatibility
• Available in concrete Half Round and Universal
Angle Ridge Tiles and Rosemary Clay Half Round
Ridge Tiles
• Not suitable for use with Uni-Vent Rapid Ridge,
Rapid Vented Ridge Systems or on hip details
• Cannot be used as a gas flue
365
Half Round Ridge Ventilation Terminal (concrete)
with DryVent Ridge System (Regent)
Ridge batten removed to accommodate
Ridge Ventilation Terminal duct
Performance
• Minimum and maximum pitch will depend on
the tile profile and whether ridge tiles are dry
fixed or mortar bedded
• The effective ventilation area for each terminal is
8,400mm2
• To achieve roof space ventilation of 5,000mm2/m
run, they should be spaced at 1.68m centres
• The pressure/air flow resistance of the terminal
is as follows:
At 15 litres/sec – 6.5 Pa
At 30 litres/sec – 26 Pa
At 60 litres/sec – 104 Pa
Regent Tile. Must be
mechanically fixed
W
Ridge Vent Terminal (Half Round shown)
248
118
Ridge Tile
Half Round
Universal Angle
Rosemary Half Round
Heathland
268
110
38
Vent Adaptor
(Sold Separately)
S.W. ridge batten
Clamping Plate
and Woodscrews
Ridge batten
fixing straps
Flexible Pipe. For use with
soil pipes or mechanical
ventilation
Flexible Pipe.
For use with
soil pipes or
mechanical
ventilation
660
200
Terminal Adaptor
Spirtech 100 or 250
100
U
Ridge Ventilation Terminal
Trussed rafter
U
V
W
X
98
106
128
98
256
255
256
256
450
450
450
450
52
34
52
52
X
228
Half Round Ridge Ventilation
Terminal (concrete)
Terminal Adaptor
274
V
Section through Ridge Ventilation Terminal with Dry
Ridge System (underlay omitted for clarity)
Flexible Pipe
(Sold Separately)
Guidance Notes
• Ridge Ventilation Terminals are suitable for timber trussed rafter and timber sarking
constructions. Where traditional timber rafter construction is used, trimmers will be
required for each terminal position to allow a 300mm section of the ridge board to
be removed.
• Where Ridge Ventilation Terminals are used in conjunction with Dry Ridge or
DryVent Ridge and are required in close proximity, at least one rafter spacing will be
required between each terminal to allow adequate fixing of the ridge batten after a
section has been removed.
• The position of the Ridge Ventilation Terminal should not be within 600mm of a gas
flue such that foul gases can vent back into the building.
• The Ridge Ventilation Terminal is not suitable where extracted air exceeds 80ºC.
Please use the Gas Flue Ridge Terminal (see next page).
• For soil pipe termination do not install within 3 metres horizontally and 900mm
vertically of an opening e.g. roof windows and roof space ventilation.
• When connected to pipework or ducting, it is recommended that where water is
likely to accumulate, joints are sealed and a condensation trap is fitted.
Components
Each Ridge Ventilation Terminal is supplied ready assembled from the following:
• Terminal cap and duct (uPVC – grey)
• Ridge Tile (concrete/clay – various)
Where the Ridge Ventilation Terminal needs to be connected to a duct or pipe of 110mm
diameter, a Terminal Adaptor and Flexible Pipe are available.
INTERACTIVE SECTION
www.redland.co.uk/ventterminal
Ridge Ventilation Terminal
249
Gas Flue Ridge Terminal
The Gas Flue Ridge Terminal is designed for use on duo-pitched roofs in conjunction
with concrete Half Round and Universal Angle Ridge Tiles on Dry-fix or bedded
ridges. The Terminal is of low air-flow resistance design, to enable flue gases to escape
even under high wind speed conditions.
Gas Flue Ridge Terminal with Dry Ridge System (Mini Stonewold)
50mm gap from top batten
to center line of ridge
• Not suitable for gas fired condensing boilers.
For condensing boilers use a Redland Ridge
Tile Outlet
• Not suitable for use as a Ventilation tile. For roof
space, mechanical and soil pipe ventilation, please
use the Redland Ridge Ventilation Terminal
Compatibility
• Available in concrete Half Round and Universal
Angle Ridge Tiles
• Gas Flue Blanking Plates packs required for Dry
& DryVent Ridge (except with Norfolk Pantile).
Norfolk Pantile Gas Flue Dry Grille Fillers
required for Norfolk Pantile Dry &
DryVent Ridge
• Not suitable for use with Rapid Vented Ridge or
Uni-Vent Rapid Ridge
Performance
• Minimum and maximum pitch will depend on the
tile profile and whether ridge tiles are dry fixed
or mortar bedded
• The Terminal is suitable for gas appliances of
rated input not exceeding 60kW, but it is not
suitable for terminating flues from traditional coal
or oil burning appliances. Please check suitability
with your gas coal effect fire supplier
• This product is only suitable where the flue can
be terminated through a 100mm or 125mm type
‘R’ adaptor (not supplied by Redland)
Mini Stonewold Slate.
Must be mechanically fixed
118
Y
Ridge Tile Outlet
(Half Round shown)
250
Gas Flue Terminal
uPVC Profile Filler
Unit with gas flue
blanking plates
Clamping Plate
and Woodscrews
‘R’ type adaptor
Gas Flue
Terminal
Vented
Ridge
450
Non Vented
Ridge
600
• Sealing Gasket (neoprene – black)
In addition, there is an Extension Adaptor which has British Gas approval, that
should be pre-assembled to the Terminal. Assembly of the ‘R’ type adaptor (not
suppied by Redland) can then be achieved from within the roof space.
INTERACTIVE SECTION
9
84
200
295
256
Sealing Gasket
1650mm of non-vented ridge required
by Gas Flue Terminal
(to comply with Building Regulations)
295
20
S.W. Ridge batten
Guidance Notes
• Gas Flue Ridge Terminals are suitable for timber trussed rafter and timber sarking
constructions. Where traditional timber rafter construction is used, trimmers will be
required for each terminal position to allow a 400mm section of the ridge board to
be removed.
• Gas Flue Ridge Terminals must have a minimum 600mm of ridge tile between units.
• The top batten should be placed so as to leave a minimum air gap of 25mm to the
Extension Adaptor. The underlay and any timber sarking should be cut back to the
line of the batten.
• The ‘R’ type adaptor and Extension Adaptor must be connected to the Terminal with
the nuts and washers provided. A gasket must be placed between each component
to provide an effective seal.
• When fitting Gas Flue Ridge Terminals, a non-vented ridge is required within 600mm
on either side of the Gas Flue to comply with Building Regulations.
Components
Each Gas Flue Ridge Terminal is supplied ready assembled from the following components:
• Ridge Tile (concrete – various colours)
• Bird Screen (stainless steel)
600
355
221
Gas Flue Ridge Terminal
Universal Angle Gas Flue
Ridge Terminal
‘R’ type adaptor
(not supplied by Redland)
256
450
450
Ridge Batten Fixing Straps
Gas Flue Extension Adaptor
Spirtech 100 or 250
underlay cut back to line
of top batten
Features
• Tried and tested and complies with BS 5534:2003
requirements for mechanical fixing
• Complies with BS 5440-2:2009
• Guaranteed weathertight and secure for 15 years
when used with the Redland range of tiles and slates
Section through Gas Flue Ridge Terminal with Dry
Ridge System (underlay omitted for clarity)
Extension Adaptor
(Sold Separately)
10
10
330
Gas Flue Ridge Terminal
Half Round
Universal Angle
Y
170
167
330
Sealing Gasket
(Sold Separately)
www.redland.co.uk/gasflue
Gas Flue Ridge Terminal
251
DryVent Monoridge System
The DryVent Monoridge System provides a continuous weathertight ventilation path
from the roof void to the outside.The mechanically-fixed system complies with
the requirements of the Building Regulations.
Features
Performance
• Provides a neat and attractive finish
• Easy to install and can be laid even when bad
weather is expected
• Ventilates to comply with BS 5250:2011,
therefore reducing the risk of harmful
condensation in the roof
• Tried and tested and complies with
BS 5534:2003 requirements for mechanical fixing
• Guaranteed weathertight and secure for 15 years
when used with the Redland range of tiles
and slates
• Minimum pitch will depend upon the minimum
pitch of the roof tiles but must not be less
than 15°
• Maximum pitch for DuoPlain, Landmark Double
Pantile, Landmark Double Roman, Grovebury,
Renown and 50 Double Roman is 47.5°;
maximum pitch for Slate 10 Range and Mini
Stonewold & MockBond is 52.5° (Stonewold II
44º). For all other interlocking tiles, maximum
pitch is 45°
• Maximum pitch for Plain Tiles is 55°
• The effective ventilation area per metre run of
ridge is 5,000mm²
Compatibility
• Available for all tiles and slates in the Redland
range except Cathedral Clay Pantile, 49 Tile and
Old Hollow Clay Pantile
• Suitable for use with concrete Half Round and
Universal Angle Ridge Tiles
DryVent Monoridge System (Cambrian)
Guidance Notes
• The DryVent Monoridge System is suitable for traditional timber rafter, timber
trussed rafter and rigid sarking constructions.
• The system is designed to fit a straight and level ridge line.
• When used in association with vertical Plain Tiles, a lead flashing or Rapid Flashing
should be dressed over the top of the vertical tiling by a minimum of 150mm.
• Care must be taken to ensure that the air passage from the roof void is not
obstructed. Allow 10mm air gap between top tile batten and monoridge fixing batten.
• Underlay is left 10mm short of apex.
• Where the system forms the junction with a flat roof, the flat roof covering should
lap behind the downstand leg of the monoridge. Ensure there is sufficient clearance
between the downstand leg and the flat roof tilting fillet.
• The system may be used with both Half Round and Universal Angle Monoridge Tiles.
• When using the system with Rosemary clay plain tiles, use Landmark Monoridge Tiles.
• Mechanically fix all slates or tiles on the top course.
• Rosemary Eave/Top Tile does not hang on the final plain tile course. Instead the
Eave/Top tile must be twice nailed to an additional batten that is turned on its side.
Top and second top batten positions from apex are 10mm and 50mm respectively.
uPVC Monoridge to Ridge Seal
Universal Angle Monoridge
25mm board,
screw fixed into
trussed rafters
uPVC Profile Filler Unit
Spirtech 100 or 250 underlay left 10mm
short of apex to allow for ventilation
50mm S/S
Woodscrew
with Neoprene
Washer
Trussed rafter
450
154
Components
• Each pack contains sufficient components to secure 6 concrete Monoridge Tiles
Each pack contains:
• Profile Filler Units (uPVC – grey).
• Monoridge, Ridge to Ridge Seal (polypropylene – black).
• Fixing Screws (stainless steel) and Washers (neoprene).
• In addition, concrete Monoridge Tiles will be required in a colour to suit, with
matching Mono Block-end Ridge Tiles, left or right-hand, at all gable ends.
• A timber batten, 25mm thick, must be fixed vertically to allow monoridge tile fixing.
150
P
273
256
90
19
110
Monoridge Tile (Universal Angle shown)
Ridge to Ridge Seal
Monoridge Tile
Half Round 98
Universal Angle 106
252
INTERACTIVE SECTION
P
98
106
www.redland.co.uk/drymonoridge
Dryvent Monoridge
253
RedLine Ventilation Tiles For Interlocking Tiles And Slates
The RedLine Ventilation Tile provides roof space ventilation through the leading edge
of the tile ensuring that the clean lines of the roof are maintained. It is ideal for use
where alternative eaves and ridge ventilation systems are not appropriate and can
also be used for mechanical extraction and soil pipe ventilation.
Features
• Identical interlocks to the tiles ensure a simple and
weathertight installation
• Ventilates to comply with BS 5250:2011, therefore
reducing the risk of harmful condensation in the roof
• Tried and tested and complies with BS 5534:2003
requirements for mechanical fixing
• Complies with BS EN 12056-2:2000
• Guaranteed weathertight and secure for 15 years
when used with the Redland range of tiles and slates
Performance
• The pitch range of each RedLine Ventilation Tile will
depend upon the minimum and maximum pitch of
the relevant tile profile
• Maximum headlap is the same as that for the
relevant tile profile
• The effective ventilation area for each unit is a
minimum of 6,000mm² apart from DuoPlain
• To achieve roof space ventilation of 5,000mm²/m
run, RedLine Ventilation Tiles should be spaced
at 1.2m centres
• To achieve 10,000mm²/m run, space at 0.6m centres
• The pressure/air flow resistance of each RedLine
Ventilation Tile is shown in the table on the next page
• Each RedLine Ventilation Tile is supplied complete
with fixings and an underlay seal
DuoPlain
• Minimum pitch 25°, Maximum pitch 90°
• The effective ventilation area for each unit
is 7,850mm²
• To achieve roof space ventilation of 5,000mm²/m
run, Redline DuoPlain Tile Ventilation Units should
be spaced at 1.57m centres
• To achieve 10,000mm² run, space at 0.78m centres
RedLine Ventilation Tile connected to Flexible Pipe (Regent)
RedLine Ventilation Tile to parapet wall gutter (Mini Stonewold)
•
•
•
•
RedLine Ventilation Tile positioned as close as possible
to top of insulation, but not on eaves course
Polypropylene Underlay Seal lapped
in with roofing underlay
Mini Stonewold RedLine Ventilation Tile.
Must be nailed and clipped
Spirtech 100 or 250
•
Spirtech 100 or 250
•
•
•
Parapet wall gutter
Regent RedLine Ventilation Tile.
Must be nailed and clipped
Flexible Pipe for use with soil
vent and mechanical
extraction systems
•
Tilting fillet
332
Flexible Pipe
Components
RedLine Ventilation Tiles are manufactured from UV protected, Medium
Density Polyethylene and are available for most colours in our range. Redland
Duoplain tile ventilation units are manufactured from PVC. For colour
availability see table.
• The RedLine Ventilation Tile is used with the Flexible Pipe (9172) for connecting
to a 110mm soil vent.
• Every RedLine Ventilation Tile is supplied complete with a Underlay
Seal (polypropylene-black).
• All RedLine Ventilation Tiles come with fixing instructions.
330
176
43 Terracotta Brindle
44 Brown Brindle
45 Rustic Black
47 Brecon Grey
52 Breckland Brown #4
53 Breckland Black #2
63 Black
64 Blue #5
77 Charcoal Grey
78 Rustic Red
464
464
464
464
464
464
512
352
560
40 Rustic Brown
116
116
116
116
116
116
128
88
140
39 Farmhouse Red #3
29
29
29
29
29
29
32
22
35
Compatibility &
Colour Table
38 Flame Red
60 L/sec
36 Tudor Brown
30 L/sec
34 Terracotta
Landmark Double Pantile
Landmark Double Roman
Regent
Grovebury
50 Double Roman
Renown
Slate 10 Range
Mini Stonewold
DuoPlain
Air flow rate
15 L/sec
30 Slate Grey
Pressure/Air Flow
Resistance (Pa)
11 Tuscan Red#1
660
Landmark Double Pantile
Landmark Double Roman
Regent
Grovebury
50 Double Roman
Renown
Mini Stonewold
DuoPlain
Slate 10 Range
•
-
•
•
•
•
•
•
•
•
•
•
•
-
•
•
•
•
•
-
•
•
•
•
•
•
•
-
•
•
•
•
-
•
•
-
•
-
•
•
•
•
•
•
-
•
•
•
-
•
•
•
•
-
•
-
315
120
195
110
RedLine DuoPlain Tile Underlay Seal
RedLine DuoPlain Tile Ventilation Adaptor
RedLine DuoPlain Tile Base Unit
118
Tile Profile
A
385
#1 Use 38 Flame Red RedLine Vent
#2 Use 30 Slate Grey
#3 Use 34 Terracotta
#4 Use 36 Tudor Brown
#5 Use 63 Black
660
106
440
C
20
254
118
Guidance Notes
Suitable for roof space ventilation and mechanical extraction.
Suitable for soil vent pipe termination for single and two storey housing.
Each RedLine Ventilation Tile should be nailed and clipped.
The Underlay Seal must always be installed to maintain the integrity of the
roofing underlay.
When using the RedLine Ventilation Tile for roof space ventilation where
insulation is between the rafters, ensure the spigot pipe is clear of the
insulation and cut if necessary.
RedLine Ventilation Tiles are not suitable for hot flue gases, please use the
Gas Flue Ridge Terminal.
RedLine Ventilation Tiles must not be laid adjacent to one another.
For soil pipe termination do not install within 3 metres horizontally and
900mm vertically of an opening e.g. roof windows and roof space ventilation.
When connected to pipework or ducting, it is recommended that where
water is likely to accumulate joints are sealed and a condensation trap is fitted.
Underlay Seal
118
Flexible Pipe
B
Landmark Double Pantile
Landmark Double Roman
Regent
Grovebury
50 Double Roman
Renown
Slate 10 Range
Mini Stonewold
A
B
C
108
114
113
108
114
110
124
119
172
168
180
172
168
159
165
149
34
31
32
34
31
31
32
30
INTERACTIVE SECTION
www.redland.co.uk/redlinevent
Redline Ventilation Tiles For
Interlocking Tiles And Slates
RedLine Vent
255
RedLine Plain Tile Ventilation Units
This range of ventilators maintains the beauty of the plain tiled roof. They are ideal
for roof space ventilation where alternative eaves and ridge ventilation systems are
not appropriate. They can also be used for mechanical extraction and soil pipe
ventilation when fitted with their adaptors.
Features
• Minimal visual impact
• Easy to install
• Ventilates to comply with BS 5250:2011,
therefore reducing the risk of harmful condensation
in the roof
• Tried and tested and complies with BS 5534:2003
requirements for mechanical fixing
• Complies with BS EN 12056-2:2000
• Guaranteed weathertight and secure for 15 years
when used with the Redland range of tiles
and slates
DuoPlain
• Available for all our plain tiles. For colour availability
please refer to the table on the next page
RedLine Vent Codes
Tile Colour
Vent Colour
Brown
Antique Red
Cotswold
Hedgerow Brown
Natural Red
Slate Grey
Terracotta
Tudor Brown
Farmhouse Red
Breckland Brown
Breckland Black
Rustic Red
Brown
Antique Red
Cotswold
Hedgerow Brown
Natural Red
Slate Grey
Terracotta
Tudor Brown
Terracotta
Tudor Brown
Slate Grey
Rustic Red
911902
911903
911912
911918
911927
911930
911934
911936
911934
911936
911930
911978
Heathland
Wealden Red
Autumn
Ember
Manor House MIx
Elizabethan
Antique Red
Autumn
Autumn
Manor House Mix
Elizabethan
911903
911923
911923
911920
911926
Rosemary
Clay Classic
Red
Light Mixed Brindle
Medium Mixed Brindle
Blue Brindle
Burnt Blend
Russet Mix
Dark Antique
Red
Medium Mixed Brindle
Medium Mixed Brindle
Blue Brindle
Autumn
Hedgerow Brown
Dark Antique
911980
911982
911982
911987
911923
911918
911995
Plain Tile
Performance
• For concrete and Rosemary clay plain tiles
35° - 90°
• Minimum headlap 65mm below 90°.
Maximum headlap 88mm
• The effective ventilation area is 6,000mm²
• To achieve roof space ventilation of 5,000mm²/m
run,RedLine Plain Tile Ventilation Units should be
spaced at 1.2m centres
• To achieve 10,000mm²/m run, space at
0.6m centres
• The pressure/air flow resistance of each RedLine
Plain Tile Ventilation Unit is shown in the table on
the next page
RedLine PlainTile Ventilation Unit (Plain Tile)
•
•
•
•
Code
•
Underlay Seal
RedLine Plain Tile Ventilation Unit
(Secured with four nails)
•
Spirtech 100 or 250
•
Trussed rafter
•
Guidance Notes
Suitable for roof space ventilation and mechanical extraction.
Suitable for soil vent termination for single and two storey housing.
Each RedLine Plain Tile Ventilation Unit should be secured with four nails.
A RedLine Underlay Seal must always be installed to maintain the integrity of the
roofing underlay.
When using the RedLine Plain Tile Ventilation Unit for roof space ventilation where
insulation is between the rafters, ensure the spigot pipe is clear of the insulation and
cut if necessary.
RedLine Plain Tile Ventilation Units are not suitable for hot flue gases, please use the
Gas Flue Ridge Terminal.
For soil pipe termination do not install within 3 metres horizontally and 900mm
vertically of an opening e.g. roof windows and roof space ventilation.
When connected to pipework or ducting, it is recommended that where water is
likely to accumulate joints are sealed and a condensation trap is fitted
Components
• RedLine Plain Tile Ventilation Units are manufactured from UV protected, Medium
Density Polypropylene. For colour availability see table below.
• The RedLine Plain Tile Ventilation Unit can be used with Adaptor (9175) and Flexible
Pipe (9172) for connecting to a 110mm soil vent pipe or mechanical ventilation
duct. Each are sold separately.
• Each RedLine Plain Tile Ventilation Unit is supplied with a clear PVC underlay seal.
• All units are supplied with fixing instructions.
RedLine PlainTile Ventilation Unit connected to Flexible Pipe
Underlay Seal
Pressure/Air Flow Resistance (Pa)
385
508
Spirtech 100 or 250
Air flow rate
295
17
RedLine Plain Tile Ventilation
Unit (Secured with four nails)
660
274
200
Plain Tile
160
15 L/sec
30 L/sec
60 L/sec
34
136
544
Trussed rafter
INTERACTIVE SECTION
118
75
110
274
RedLine
Ventilation Adaptor
Flexible Pipe
RedLine Plain Tile Base Unit
256
RedLine Plain Tile Underlay Seal
RedLine Plain Tile Ventilation Adaptor
Flexible Pipe
www.redland.co.uk/redlinevent
Redline Plain Tile Ventilation Units
257
ThruVent
The ThruVent Tile is a means of incorporating ventilation within the roof slope where
alternative eaves and ridge ventilation systems are not appropriate. It can also be
used for mechanical extraction and soil pipe ventilation. Manufactured mainly from
concrete, the ThruVent Tile provides a neat, secure fit with surrounding tiles or slates.
Applications
• Roof space ventilation, for control
of condensation
• Mechanical extraction ventilation terminal
• Soil ventilation: Use 4.5k for low rise building
(up to 2 storey). No building height restriction
applies to the 8.8k ThruVent
4.5k
4.5k
8.8k
8.8k
8.8k
0.9
0.45
1.76
0.88
0.35
Flexible Pipe.
For use with soil pipes
and mechanical ventilation
8.8k ThruVent (50 Double Roman)
Spirtech 100 or 250
Hi-Flow ThruVent Tile
• Effective ventilation area of 15,000mm2
• Suitable for low level ventilation at valleys where
insulation is positioned between the rafters
(partial-fill). Install one Hi-Flow ThruVent tile per
rafter space either side of the valley to provide
effective ventilation equivalent to 25,000mm²/m
• Available for Cambrian Slate only
Range
Compatible Tile Profile
Slate
Cambrian Slate
Plain Tile
Plain Tile
Profile
Cathedral Clay Pantile/
Norfolk Pantile/Old
Hollow Clay Pantile
15L/sec
30L/sec
60L/sec
22
88
352
25
100
464
23
92
368
49 Tile
29
116
464
Slate
Slate 10 Range
Stonewold II
Mini Stonewold
2
3
4
8
12
15
31
49
62
Profile
Landmark Double Pantile/
Grovebury
2
8
32
Landmark Double Roman/
50 Double Roman
2
10
38
Regent
Renown
2
3
8
12
34
47
3.5
14
56
Slate
Cambrian Slate
* Equivalent ventilation area 4,500mm², Downpipe diameter 75mm ** Equivalent ventilation area 8,800mm²,
Downpipe diameter 100mm *** Equivalent ventilation area 15,000mm², no downpipe
50 Double Roman ThruVent Tile
Tile Profile
S
T
124
105
122
107
60
9
33
40
88
177
114
85
98
85
98
86
103
24
45
22
31
23
31
23
21
26
4.5k ThruVent Tile (A=180, B=120, C=175, D=83)
89
440
230
165
Cambrian Slate
Cathedral Clay Pantile/Old Hollow Clay Pantile
Norfolk Pantile
49 Tile
Underlay Seal
175
100
100
Guidance Notes
• The Underlay Seal provided should always be installed to maintain the integrity of
the roofing underlay.
• Where Plain Tile ThruVents are positioned between each rafter spacing, they should
be staggered on alternate courses.
• Where ThruVent Tiles are used in combination with insulation between the rafters,
ensure that the pipe on the under-side is clear of the insulation, by cutting the pipe
where necessary.
• ThruVent Tiles are not suitable for hot flue gases, please use the Gas Flue Ridge
Terminal (see page 96).
• Plain Tile ThruVents are installed to 100mm gauge only.
• For soil pipe termination do not install within 3 metres horizontally and 900mm
vertically of an opening e.g. roof windows and roof space ventilation.
• For details to install above a parapet wall gutter (see page 259).
• When connected to pipework or ducting, it is recommended that where water is
likely to accumulate joints are sealed and a condensation trap is fitted.
Components
• The ThruVent Tile is manufactured in concrete with a PVC ventilation unit and cap.
The caps are colour co-ordinated to the colour of the tile base
• The Plain Tile ThruVent consists of a three tile moulded unit, batten support
brackets and clips.
• Each ThruVent Tile is supplied with a Polypropylene – black Underlay Seal.
• A Flexible Pipe is available for connecting to a 110mm soil vent pipe or mechanical
ventilation duct.
Guidance Notes (Hi-Flow ThruVent)
• Hi-Flow ThruVent Tile installed in first full slate adjacent to valley.
• Our Underlay Seal must always be installed to maintain the integrityof the roof
underlay.
• Each Hi-Flow ThruVent must be mechanically fixed.
• Keep spigot clear of the insulation and cut if necessary.
• Not suitable for hot flue gases, use the Gas Flue Ridge Terminal.
• When connected to pipework or ducting, it is recommended that where water is
likely to accumulate joints are sealed and a condensation trap is fitted.
8.8k ThruVent Tile (A=303 , B=202 , C=200 , D=109)
385
Performance
• Minimum and maximum pitch will depend on
the profile and surface finish
• Minimum and maximum headlap will depend on
the tile profile.
265
165
32
690
T
660
A
4.5k Plain Tile ThruVent
20
118
Flexible Pipe for 4.5k ThruVent
B
185
100
Underlay Seal
258
8.8k ThruVent**
5,000
10,000
5,000
10,000
25,000
Underlay Seal
HiFlow***
ThruVent
ThruVent
spacing (m)
4.5k ThruVent*
Spirtech 100 or 250
• For Rosemary clay plain tiles and Heathland tiles
use the RedLine Plain Tile Ventilation Unit, refer
to the previous page for colour availability
• To achieve the specified roof space ventilation
the ThruVents should be spaced according to the
table below:
Roof space
ventilation (mm2/m)
Pressure/Air Flow Resistance (Pa)
49 Tile ThruVent Tile
118
Features
• Easy to install
• Ventilates to comply with BS 5250:2011,
therefore reducing the risk of harmful
condensation in the roof
• Tried and tested and complies with
BS 5534:2003 requirements for mechanical fixing
• Complies with BS EN 490:2011 and BS EN
12056-2:2000
• Guaranteed weathertight and secure for 15 years
when used with the Redland range of tiles
and slates
• Available for all tiles and slates in the Redland
range except DuoPlain and Natural Slate
4.5k ThruVentTile connected to Flexible Pipe (49 Tile)
Flexible Pipe for 8.8k Thruvent
C
S
D
4.5k & 8.8k ThruVent Tile
Slate 10 Range
Stonewold II
Mini Stonewold
Landmark Double Pantile
Landmark Double Roman
Grovebury
50 Double Roman
Regent
Renown
INTERACTIVE SECTION
www.redland.co.uk/thruvent
Thruvent
259
Ornamental tiles, finials and ridges
Our concrete ornamental ridge fittings are compatible with mortar bedding, dry-fix
and ventilated systems, enabling a complete roof, covered by our 15 Year Roof
System Guarantee, to be easily achieved without compromising good looks.
Product
Codes
Overall Size
Height of Finial
Weight
(L x W x H mm)
(mm)
(kg)
7529
7530
7527
7528
300 x 259 x 306
300 x 259 x 430
300 x 256 x 298
300 x 256 x 415
200
200
200
200
8.5
12.8
8.1
11.6
Product
Codes
Overall Size
Height of Crest
Weight
(L x W x H mm)
(mm)
(kg)
Scroll
Universal Angle Ridge
Universal Angle Ridge Block-end
Half Round Ridge
Half Round Ridge Block-end
Cockscomb Ridge
Universal Angle Ridge
Universal Angle Ridge Block-end
Half Round Ridge
Half Round Ridge Block-end
7468
7538
7458
7540
450 x 259 x 206
450 x 259 x 330
450 x 256 x 198
450 x 256 x 315
100
100
100
100
7.7
9.6
7.6
8.8
Short Ball Top
Universal Angle Ridge
Universal Angle Ridge Block-end
Half Round Ridge
Half Round Ridge Block-end
7485
7487
7481
7843
300 x 259 x 376
300 x 259 x 500
300 x 256 x 368
300 x 256 x 485
270
270
270
270
7.4
11.7
7.0
10.5
Three Hole Crested Ridge
Universal Angle Ridge
Universal Angle Ridge Block-end
Half Round Ridge
Half Round Ridge Block-end
7462
7558
7455
7560
450 x 259 x 256
450 x 259 x 380
450 x 256 x 248
450 x 256 x 370
150
150
150
150
8.5
10.4
8.4
9.6
Tall Ball Top
Universal Angle Ridge
Universal Angle Ridge Block-end
Half Round Ridge
Half Round Ridge Block-end
7486
7488
7482
7484
300 x 259 x 476
300 x 259 x 600
300 x 256 x 468
300 x 256 x 585
370
370
370
370
7.8
12.1
7.4
10.9
Fleur-de-Lys Ridge
Universal Angle Ridge
Universal Angle Ridge Block-end
Half Round Ridge
Half Round Ridge Block-end
7467
7568
7457
7570
450 x 259 x 256
450 x 259 x 380
450 x 256 x 248
450 x 256 x 370
150
150
150
150
8.1
10.0
8.0
9.2
Fleur-de-Lys
Universal Angle Ridge
Universal Angle Ridge Block-end
Half Round Ridge
Half Round Ridge Block-end
7491
7491
7489
7490
300 x 259 x 526
300 x 259 x 650
300 x 256 x 518
300 x 256 x 635
420
420
420
420
7.8
12.1
7.4
10.9
Ornamental Ridge
Redland offers concrete finials in four designs for
both Universal Angle and Half Round Ridges. These
finials have been designed to replicate the most
popular ornamental features found within the built
environment, with the added benefit of being fully
compatible with all our ridge fixing systems.
Finials
With decorative effects being incorporated more
frequently into roof designs, we are the only company
to offer Ornamental Plain Tiles with a guaranteed
performance in all weathers down to 40 degrees pitch.
Following extensive testing at our wind tunnel facility, the
guarantee is offered across both concrete plain tile and
Rosemary clay plain tile ranges.
Club
Concrete Plain Tile (6251)
Club
Heathland (6671)
Club
Rosemary Classic (6521)
Guidance Notes: Fixings - all Finials and Ornamental Ridges should be fixed using 100mm stainless steel woodscrews
260
261