Sweets Armacell 404
Transcription
Sweets Armacell 404
FM APPROVED INSULATION PRODUCTS & ACCESSORIES • AP/Armaflex® SHEET & ROLL INSULATION • AP/Armaflex® SS • AP/Armaflex® • AP/Armaflex® W • AP/Armaflex® SA TUBE INSULATION ® • AC/Armaflex® Coil • AP/Armaflex Duct Liner • HT/Armaflex® • ArmaTuff® 25 • NH/Armaflex® • ArmaTuff® Silver • Tubolit • ArmaTuff® White • Tubolit® SS • HT/Armaflex® ® • NH/Armaflex® ACCESSORIES • Armafix IPH/NPH Pipe Hangers • Armaflex® 520 and 520 BLV Adhesives • AP/Armaflex® Insulation Tape • WB/Armaflex® Finish PIPE INSULATION SELF-SEAL PIPE INSULATION Performance approved through continuing supervision by Factory Mutual Approvals. FM APPROVED PROVEN PERFORMANCE LEADER DESCRIPTION AP Armaflex and AP Armaflex SS Self-Seal Pipe Insulations are 25/50-rated flexible elastomeric thermal insulations, black in color, supplied as tubing in popular sizes up to 6" IPS. (See wall thicknesses, next page.) The expanded closed-cell structure of AP Armaflex makes it an efficient insulation. It is manufactured without the use of CFC’s, HCFC’s or HFC’s. It is also formaldehyde free, dust free, fiber free and resists mold and mildew. AP Armaflex Pipe Insulation, through 1″ wall thickness has a flame-spread index of less than 25 and a smoke-developed index of less than 50 as tested by ASTM E 84 and CAN/ULC S-102, “Method of Test for Surface Burning Characteristics of Building Materials.” AP Armaflex and AP Armaflex SS are approved through continuing supervision by Factory Mutual Approvals and consistently provide actual values on these key performance criteria for mechanical system insulation: Thermal Conductivity: 0.27 BTU-in/hr. ft2 °F Water Vapor Permeability: 0.08 perm-inch Fire Rating: will not contribute significantly to fire (simulated end use testing) Factory Mutual Approvals has determined that AP Armaflex will not contribute significantly to fire through tests deemed more predictive of end use performance than ASTM E 84. Factory Mutual Approvals supervision includes continuing testing by these methods: UBC 26-3 Room Fire Test Method and the Factory Mutual Approvals Full Scale Horizontal Simulated Pipe Chase Test. Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. USES AP Armaflex Pipe Insulations are used to retard heat gain and control condensation drip from cold-water plumbing, chilled-water, and refrigeration lines. They also efficiently reduce heat flow for hot-water plumbing and liquidheating and dual-temperature piping. (See chart next page for recommended temperature usage range.) NOTE: Armaflex insulation products must be installed according to “Installation of Armaflex Insulations.” Proper installation is required to assure Armaflex insulation performance. 2 For use on cold pipes, AP Armaflex thicknesses have been calculated to control condensation on the insulation outer surface, as shown in the table of thickness recommendations. RESISTANCE TO MOISTURE VAPOR FLOW The closed-cell structure of AP Armaflex Insulations effectively retards the flow of moisture vapor. AP Armaflex is considered a low-transmittance vapor retarder. AP Armaflex normally requires no supplemental vaporretarder protection. Additional vapor-retarder protection may be necessary for AP Armaflex when installed on very low temperature piping or where exposed to continually high humidity conditions. APPLICATION AP Armaflex Pipe Insulation in unslit tubular form can be slipped onto piping before it is connected, or it can be slit lengthwise and snapped over piping already connected. Apply AP Armaflex SS Insulation by placing the slit tubing over pipe. Peel release liners from adhesive surfaces and apply firm pressure along entire longitudinal joint. Secure butt ends using Armaflex 520 Adhesive or, where a low V.O.C. adhesive is required, Armaflex 520 BLV Adhesive. Fitting covers may be fabricated from metered-cut AP Armaflex Self-Seal tubing. Fabricate miter-cut fitting covers and assemble with Armaflex 520 or 520 BLV Adhesive. Install over pipe fitting and seal to adjoining sections of pipe insulation with 520 or 520 BLV Adhesive. 520 Adhesives are contact adhesives; therefore, in all cases, both surfaces to be joined are coated with adhesive. AP Armaflex is designed for installation above ground. Indoors, no protective finish is required. Outdoors, a weather-resistant protective finish is to be applied. The recommended protective finish is WB Armaflex Finish; however, other compatible finish systems are not ruled out. SPECIFICATION COMPLIANCE AP Armaflex developed to meet: ASTM C 534, Type I — Tubular Grade 1 ASTM E 84 NFPA 225 UL 723 CAN/ULC S102 UL 94 5V-A, V-O, File E 55798 NFPA 90A, 90B ASTM D 1056, 2B1 MIL-P-15280J — Form T MIL-C-3133C (MIL STD 670B),Grade SBE 3 CGSB CAN 2-51.40-M80 MEA 96-85-M City of LA - RR 7642 FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: info.us@armacell.com. Website: www.armacell.com AP ARMAFLEX AND AP ARMAFLEX SS PIPE INSULATION PHYSICAL PROPERTIES Approved by Factory Mutual Approvals to meet or exceed key property values. PHYSICAL PROPERTIES Thermal conductivity, Btu • in./h • ft2 • °F (W/mk) 75°F (24°C) mean temp 90°F (32°C) mean temp TEST METHOD NOTES 0.27 (0.039) 0.276 (0.040) -13 Water vapor permeability, perm-in. [Kg/(s • m • Pa)] 0.08 (1.16 x 10 ) ASTM E 96 Procedure A Flame spread and smoke developed index through 1" (25mm) thicknesses 25/50 ASTM E 84 Water absorption, % by volume 0.2 ASTM C 209 Ozone resistance GOOD – Upper use limit (See note 1) AP Armaflex AP Armaflex SS 220°F (105˚C) 180˚F (82˚C) (See note 3) – Lower use limit (See note 2) AP Armaflex AP Armaflex SS -70°F (-57˚C)* (See note 2) -70°F (-57˚C)* – 3/8" , 1/2" , 3/4" , 1" (10, 13, 19, 25 mm) – 3/8" , ID to 6" IPS (10 mm ID to 168mm)** 6' (1.8 m) – – AP Armaflex Sizes Wall thickness, inches (nominal) Inside diameter, tubular form Length of sections, feet, tubular form AP Armaflex SS Sizes Wall thickness, inches (nominal) Inside diameter, tubular form Length of sections, feet, tubular form 1 On the heating cycle, AP Armaflex Pipe Insulation will withstand temperatures as high as 220°F (105°C). 520 Adhesive may be used with pipe insulation applications up to 220°F (105°C) or, where a low V.O.C. adhesive is required, use Armaflex 520 BLV Adhesive. 2 At -20°F (-29°C), flexible AP Armaflex Insulation becomes hard and, as temperatures drop below -20°F (29°C), will be increasingly brittle; however, this hardening characteristic does not affect thermal efficiency or water vapor permeability. For applications of -40°F to -70°F (-40°C to -57°C), contact Armacell. 3 AP Armaflex SS has a temperature use limit of -40°F to +220°F (-40°C to 105°C) for intermittent exposure. For continuous exposure, the upper use limit is 180°F (82°C). ASTM C 177 or C 518 * For applications of -40°F to -70°F (-40°C to -57°C) contact Armacell 1/2" , 3/4" , 1" (13, 19, 25 mm) 5/8" ID to 4" IPS (15mm ID to 114mm) 6' (1.8 m) ARMAFLEX PIPE INSULATION THICKNESS RECOMMENDATIONS Thickness recommendations for controlling outer insulation surface sweating (based upon available manufactured thicknesses) PIPE SIZE LINE TEMPERATURES 50°F (10°C) 35°F (2°C) 0°F (-18°C) -20°F (-29°C) Nom Nom Nom Nom Nom Nom Nom Nom BASED ON NORMAL DESIGN CONDITIONS* 3/8" ID through 1-1/8" ID (10 mm through 28 mm) Over 1-1/8" ID through 2-1/8" ID (over 28 mm through 54 mm) Over 2-1/8" ID through 2 -5/8" ID (over 54 mm through 65 mm) Over 2 -5/8" ID through 6" IPS (over 65 mm through 168 mm) Nom Nom Nom Nom BASED ON MILD DESIGN CONDITIONS** 3/8" ID through 2-5/8" ID (10 mm through 65 mm) Over 2 -5/8" ID through 6" IPS (over 65 mm through 168 mm) Nom 3/8" (10 mm) Nom 1/2" (13 mm) Nom 3/8" (10 mm) Nom 1/2" (13 mm) Nom 1/2" (13 mm) Nom 1/2" (13 mm) BASED ON SEVERE DESIGN CONDITIONS*** 3/8" ID through 1-5/8" ID (10 mm through 40 mm) Over 1-5/8" ID through 3-5/8" ID (over 40 mm through 90 mm) Over 3-5/8" ID through 6" IPS (over 90 mm through 168 mm) Nom 3/4" (19 mm) Nom 3/4" (19 mm) Nom 3/4" (19 mm) Nom 1" (25 mm) Nom 1" (25 mm) Nom 1" (25 mm) Nom 1-1/2" (38 mm) Nom 1-1/2" (38 mm) Nom 1-1/2" (38 mm) Nom 1-3/4" (44 mm) Nom 1-1/2" (38 mm) Nom 2" (50 mm) 3/8" 3/8" 3/8" 1/2" (10 (10 (10 (13 mm) mm) mm) mm) Nom Nom Nom Nom 1/2" 1/2" 1/2" 3/4" (13 (13 (13 (19 mm) mm) mm) mm) 3/4" (19 mm) 1" (25 mm) 1" (25 mm) 1" (25 mm) 1" (25 mm) 1" (25 mm) 1-1/4" (32 mm) 1-1/4" (32 mm) Nom 3/4" (19 mm) Nom 3/4" (19 mm) NOTES Thicknesses greater than 1" (25 mm) are multiple-layer applications, see technical bulletin #30. * BASED ON NORMAL DESIGN CONDITIONS AP Armaflex in the thicknesses noted and within the specified temperature ranges will control outer insulation surface sweating indoors under normal design conditions, a maximum severity of 85°F (29°C) and 70% RH. Armacell research and field experience indicate that indoor conditions anywhere in the United States seldom exceed this degree of severity. ** BASED ON MILD DESIGN CONDITIONS AP Armaflex in the thicknesses noted and within the specified temperature ranges will control outer insulation surface sweating indoors under mild design conditions, a maximum severity of 80°F (27°C) and 50% RH. Typical of these conditions are most air-conditioned spaces and arid climates. *** BASED ON SEVERE DESIGN CONDITIONS AP Armaflex in the thicknesses noted and within the specified temperature ranges will control outer insulation surface sweating indoors under severe design conditions, a maximum severity of 90°F (32°C) and 80% RH. Typical of these conditions are indoor areas in which excessive moisture is introduced or in poorly ventilated confined areas where the temperature may be depressed below ambient. FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: info.us@armacell.com. Website: www.armacell.com 3 TECHNICAL DATA PHYSICAL PROPERTIES FAST, CRISP AND CLEAN FM APPROVED DESCRIPTION AP Armaflex W pipe insulation is a flexible elastomeric thermal insulation, white in color, supplied as unslit tubing in nominal wall thicknesses of 1/2″, 3/4″ and 1″ (13 mm, 19 mm and 25 mm). In popular sizes up to 2-5/8″ ID. The closed cell structure of AP Armaflex W makes it an efficient insulation with performance comparable to AP Armaflex. It is manufactured without the use of CFC’s, HCFC’s or HFC’s. It is also formaldehyde free, dust free, fiber free and resists mold and mildew. USES AP Armaflex W is engineered for residential and commercial air conditioning and commercial refrigeration applications in which speed and ease of installation are of primary importance, especially in open ceiling facilities. AP Armaflex W provides the thermal efficiency of AP Armaflex pipe insulation, meets all Armaflex specifications, and reduces the need for priming or painting. INSTALLATION AP Armaflex W slides on the pipe easier, making the installation job faster, hassle-free, and more profitable for contractors. The insulation includes a specially formulated lubricating powder that efficiently reduces friction, plus relaxed I.D. tolerances to accommodate elbows and fittings. AP Armaflex W installs with simple hand tools and 520 Adhesive or, where a low V.O.C. adhesive is required, use Armaflex 520 BLV Adhesives. 520 Adhesives are contact adhesives; therefore, in all cases, both surfaces to be joined are coated with adhesives. COIL LONGER, MORE EFFICIENT LESS WASTE 4 DESCRIPTION AC Armaflex Coil is a system designed for convenience and labor savings with superior toughness. It is provided in continuous-length coils, designed to minimize waste, reduce butt joints, and is packaged in easy-handle, easy-store cartons. The pipe insulation is tough but flexible elastomeric thermal insulation, black in color, supplied as continuouslength unslit tubing in nominal wall thicknesses of 3/8″ (10mm) and 1/2″ (13mm) in popular sizes up to 1-1/8″ ID. Its closed cell structure makes it an efficient insulation with the proven performance of Armaflex. It is manufactured without the use of CFC’s, HCFC’s or HFC’s. It is also formaldehyde free, dust free, fiber free and resists mold and mildew. USES AC Armaflex Coil is engineered for air conditioning applications in which speed, ease of installation, convenient handling and on-site durability are of primary importance. It slides on the pipe easier, making the installation job faster and more profitable for contractors. INSTALLATION AC Armaflex uncoils easily from its convenient carton, so it can be cut to desired lengths for longer runs with fewer seams. It also slides on the pipe easier, making the installation job faster and more profitable for contractors. The specially formulated lubricating powder effectively reduces friction, and relaxed I.D. tolerances accommodate elbows and fittings. Its thermal conductivity (0.27), WVT (0.80), flame spread and smoke developed index (25/50) and temperature use ranges (-70°F to +220°F) are the same as AP Armaflex. Installs with simple hand tools and Armaflex 520 Adhesive or, where a low V.O.C. adhesive is required, use Armaflex 520 BLV Adhesive. 520 Adhesives are contact adhesives; therefore, in all cases both surfaces to be joined are coated with adhesive. TEST METHOD Thermal conductivity, Btu • in/h • ft2 °F (W/mk) 75° (24°C) mean temp 0.27 (0.039) 0.276 (0.040) ASTM C 177 or C 518 Water Vapor permeability, [kg/(s•m•Pa)] 0.08 [1.16 x 10-13] ASTM E 96 Procedure A Water absorption by volume 0.2% ASTM C 209 Flame spread and smoke developed index through 1″ (25mm) thickness 25/50 ASTM E 84 Ozone resistance GOOD — Upper use limit 220°F (105˚C) — Lower use limit -70°F (-57°C)* — Sizes Wall thickness (nominal) 1/2″, 3/4″ and 1″ (13, 19 and 25mm) Inside diameter, tubular form 3/8″ ID to 2-5/8″ ID Length of sections, tubular form 6′ (1.83m) Density, typical range 3 3.0 – 6.0 lbs/cu ft ASTM D 1622 or D 1667 Notes 1 On the heating cycle AP Armaflex W pipe insulation will withstand temperatures as high as 220°F. 520 or 520 BLV Adhesive may be used with pipe insulation applications up to 220°F. 2 At -20°F Flexible AP Armaflex W insulation becomes hard and, as temperatures drop below -20°F, will be increasingly brittle; however, this hardening characteristic does not affect thermal efficiency or water vapor permeability. 3 For reference only. * For applications of -40°F to -70°F (-40°C to -57°C), contact Armacell. TECHNICAL DATA PHYSICAL PROPERTIES TEST METHOD Thermal conductivity, Btu • in./h • ft2 • °F (W/mk) 75°F mean temp (24°C) 90°F mean temp (32°C) 0.27 (0.039) 0.276 (0.040) ASTM C 177 or C 518 Water vapor permeability, perm-in. [Kg/(s•m•Pa)] 0.08 (1.16 x 10-13) ASTM E 96 Procedure A Water absorption, by volume 0.2% ASTM C 209 Flame spread and smoke developed index through 1″ (25mm) thickness 25/50 ASTM E 84 Ozone resistance GOOD — Upper use limit 220˚F (105°C) Lower use limit -70˚F (-57°C)* Sizes Wall thickness, (nominal) Inside diameter, tubular form Length of sections, tubular form 3/8″ (10mm), 1/2″ (13mm) 5/8″, 3/4″, 7/8″, 1-1/8″ Density, typical range 3 — Varies by I.D. 3.0 – 6.0 lbs./ft3 ASTM D 1662 or D 1667 Notes 1 On the heating cycle, AC Armaflex Coil Pipe Insulation will withstand temperatures as high as 220°F (105°C). 520 or 520 BLV Adhesive may be used with pipe insulation applications up to 220°F (105°C). 2 At -20°F (-29°C), flexible AC Armaflex Coil Insulation becomes hard and, as temperatures drop below -20°F (-29°C), will become increasingly brittle; however, this hardening characteristic does not affect thermal efficiency or water vapor permeability. 3 For reference only. * For applications of -40°F to -70°F (-40°C to -57°C), contact Armacell. FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: info.us@armacell.com. Website: www.armacell.com TAKES ON HIGH TEMPERATURES AND THE ELEMENTS HT Armaflex is a black flexible elastomeric thermal insulation specifically developed to perform in continuous high temperature applications up to +300˚F (+150°C). The formulation of HT Armaflex provides exceptional ozone and ultraviolet resistance. A closed-cell material, HT Armaflex provides low thermal conductivity, good fire behavior, low temperature flexibility and excellent protection against heat flow and water vapor diffusion. It is manufactured without the use of CFC’s, HFC’s HCFC’s. It is also formaldehyde free, fiber free, dust free and resists mold and mildew. HT Armaflex is used as insulation and protection for piping in solar collectors, refrigeration and automotive applications. The insulation withstands incidental oil contact and performs on a broad range of metal pipes and tubing in applications. Supplied in tube and roll form. HT Armaflex is installed in the same easy manner as AP Armaflex. Armaflex HT625 Adhesive is required to seal the seams and joints ASTM C 534, Type I (Tubular) Grade 2 and Type ll (Sheet) Grade 2, UL V-O 5V-A. HALOGEN-FREE NH Armaflex is a nonhalogen flexible elastomeric thermal insulation, dark grey in color, supplied as unslit tubing in nominal wall thicknesses of 1/2″ and 3/4″; sheets in thicknesses of 1/2″, 3/4″, and 1″. It was specially developed by Armacell to eliminate the density of smoke and reduce corrosive acid gases from combustion. NH Armaflex will not carry a progressive flame and is formulated without chlorine, bromines, or PVC. TECHNICAL DATA PHYSICAL PROPERTIES Thermal Conductivity BTU-in/hr sq.ft °F (W/mK) 32°F mean temperature (0°C) 75°F mean temperature (24°C) 120˚F mean temperature (50˚C) 0.05 [7.25 x 10 -14 ] ASTM E 96 Procedure A Water Absorption, % by volume 0.02 ASTM C 209 Ozone Resistance Excellent ASTM D 1149 Upper use limit 1 300°F (150°C) Lower use limit 2 -58°F (-50°C) Density, tpical range 3, lbs/ft3 3.0 – 6.0 ASTM D 1662 or ASTM D 1667 Notes 1 Suitable for systems with occasional or intermittent temperatures to 350°F (175°C), with a recommended exposure limit of one 30-minute period at 350°F (175°C) over 24 hours of operation. 2 At -20 °F (-29 °C) flexible HT/Armaflex insulation becomes hard and as temperatures drop below -20 °F (29 °C), will be increasingly brittle; however, this hardening characteristic does not affect thermal efficiency or water vapor permeability. 3 Reference Only • • • • • • • International Maritime Organization (IMO) SOLAS requirements NH Armaflex is currently specified for use on US Navy vessels UL-V-0 and HF-1 File Number E55798 ASTM C534 Type 1 (Tubular) Grade 3, Type II (Sheet) Grade 3 ASTM C 795 Nuclear Regulatory Commission Regulatory Guide 1.36 US Coast Guard Requirements (see Armacell for more details) TECHNICAL DATA NH Armaflex is used as insulation and protection for piping, tanks and air ducts, and to prevent stress corrosion with stainless steel pipes in the following applications: US Navy applications, general shipbuilding, IMO, nuclear power plants, other areas where nonhalogenated or chlorine-free materials may be required. Supplied in tube, sheet and roll form, NH Armaflex is easy to snap on or sleeve over pipework. In sheet form, it installs quickly on large flat or curved surfaces using Armaflex 520 Adhesive or, where a low V.O.C. adhesive is required, Armaflex 520 BLV Adhesive. 520 Adhesives are contact adhesives; therefore, in all cases both surfaces to be joined are coated with adhesives. For pipes and fitting covers, only seams and joints require adhesive. • Shipbuilder Electric Boat Corp. EB 4013 Antisweat and Refrigerant Insulation Systems (Sheets & Tubes). ASTM C 177 or ASTM C 518 0.275 (0.039) 0.30 (0.043) 0.32 (0.047) Water Vapor Permeability Perm-inch [Kg/s m Pa)] A closed-cell material, NH Armaflex provides low thermal conductivity low-temperature flexibility, good fire behavior, and excellent protection against water vapor diffusion. It is manufactured without the use of CFC’s, HFC’s or HCFC’s. It is also formaldehyde free, fiber free, dust free and resists mold and mildew. When installed in the same manner as standard AP Armaflex flexible insulation, NH Armaflex requires no additional vapor retarder under normal conditions. SPECIFICATION APPROVALS TEST METHOD PHYSICAL PROPERTIES TEST METHOD Thermal Conductivity, Btu • in./h • ft2 • °F (W/mK) 32°F mean temperature (0°C) 0.248 (0.036) 75°F mean temperature (24°C) 0.27 (0.039) 104°F mean temperature (40°C) 0.282 (0.041) ASTM C177 or ASTM C 518 Water Vapor Permeability Perm-inch [Kg/(s m Pa)] 0.05 [7.25 x 10-14] ASTM E 96 Procedure A Water Absorption, % by volume 0.2 ASTM C 209 Ozone resistance Excellent ASTM D 1149 Upper use limit 250°F (120°C) Lower use limit -58°F (-50°C) Toxicity Free from Halogen/Dioxin/CFC/Mercury/ Carbon Black/Heavy Metal IMO (International Maritime Organization) Combustion gas concentration Smoke density Heat release rate Flame spread Behavior in Fire Does not support progressive flaming, will not melt and drip. Meets EB 4013 specifications Meets IMO SOLAS requirements Density, tpical range 2, lbs/ft3 3.0 – 6.0 Pass Pass Pass Pass Navy Large Scale pipe insulation room/corner test ASTM D 1662 or ASTM D 1667 Notes 1 2 At -20 °F (-29 °C) flexible NH/Armaflex insulation becomes hard and as temperatures drop below -20 °F (29 °C), will be increasingly brittle; however, this hardening characteristic does not affect thermal efficiency or water vapor permeability Reference Only FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: info.us@armacell.com. Website: www.armacell.com 5 SHEET AND ROLL INSULATION SELF-ADHERING SHEET AND ROLL INSULATION Performance approved through continuing supervision by Factory Mutual Approvals. FM APPROVED PROVEN PERFORMANCE LEADER DESCRIPTION AP Armaflex and AP Armaflex SA SelfAdhering Sheet and Roll Insulation are flexible, elastomeric thermal insulations, black in color. Both are supplied in flat sheets 36″ x 48″ (.92m x 1.22m), in popular thicknesses. AP Armaflex and AP Armaflex SA are also available in 48″ (1.22m) continuous rolls in 3/8″, 1/2″, 3/4″, 1″, 1-1/2″ and 2″ (See sizes and metric conversions, next page). The insulations are furnished with a smooth skin one side which forms the outer exposed insulation surface. The expanded closed-cell structure of Armaflex makes it an efficient insulation. It is manufactured without the use of CFC’s, HCFC’s or HFC’s. It is also formaldehyde free, dust free, fiber free and resists mold and mildew. As tested by ASTM E 84, “Method of Test for Surface Burning Characteristics of Building Materials and CAN/UL S-102,” AP Armaflex Sheet Insulations in thicknesses through 1″ (25mm) have a flame-spread index of less than 25 and a smoke-developed index of less than 50. AP Armaflex and AP Armaflex SA are approved through continuing supervision by Factory Mutual Approvals and consistently provide actual values on these key performance criteria for mechanical system insulation. Thermal Conductivity: 0.27 BTU-in/hr sq.ft. °F Water Vapor Permeability: 0.08 perm-inch Fire Rating: Will not contribute significantly to fire. (simulated end-use testing) Factory Mutual Approvals has determined that AP Armaflex will not contribute significantly to fire through tests deemed more predictive of the end use performance than ASTM E 84. Factory Mutual Approvals supervision includes continuing testing by these methods: UBC 26-3 Room Fire Test Method and the Factory Mutual Approvals Full-Scale Horizontal Simulated Pipe Chase Test. Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. USES AP Armaflex is used to retard heat gain and control condensation drip from chilled water and refrigeration systems. It also efficiently reduces heat flow on hot systems. AP Armaflex Sheet/Roll Insulations are particularly adaptable for insulating ductwork, large piping and fittings, tanks, and vessels. Their flexibility allows application to curved and irregular surfaces. They are very adaptable to making all types of fitting cover insulations. The recommended temperature usage range for AP Armaflex Sheet Insulation is -70°F to +220°F (-57°C to +105°C) according to method of application. AP Armaflex sheet with 6 full adhesive coverage, and AP Armaflex SelfAdhering Sheet, may be used on surfaces with operating temperatures up to 180°F (82°C). When used for pipe insulation with adhesive adhering seams and joints only, Armaflex Sheet can be applied to lines that will operate to a limit of 220°F (105°C). For use on cold surfaces, AP Armaflex thicknesses have been calculated to control condensation on the insulation outer surface, as shown in the table of thickness recommendations. RESISTANCE TO MOISTURE VAPOR FLOW The closed-cell structure of Armaflex Insulations effectively retards the flow of moisture vapor, and Armaflex is considered a low-transmittance vapor retarder. For many applications, Armaflex needs no supplementary protection. Additional vapor-retarder protection may be necessary for Armaflex when install on very lowtemperature surfaces or piping or where exposed to continually high humidity conditions. APPLICATION AP Armaflex Sheet is installed using Armaflex 520 Adhesive or, where a low V.O.C. adhesive is required, use Armaflex 520 BLV Adhesive. For application to large flat or curved metal surfaces such as ducts, very large pipes, tanks, and vessels, full adhesive coverage is used. For applications as pipe insulation and fitting covers, only the seams and joints are adhered with adhesive. 520 Adhesives are contact adhesives; therefore, in all cases, both surfaces to be joined are coated with adhesive. AP Armaflex Self-Adhering Sheet has a factoryapplied adhesive system with long-term performance similar to 520 Adhesive. It can be applied to clean, non-oily metal surfaces. Simply remove a portion of the release liner, position sheet, adhere one edge, and then just peel and press. Seams and joints are adhered using 520 or 520 BLV Adhesive. AP Armaflex Sheet and Self-Adhering Sheet insulations are designed for installation above ground. Indoors, no protective finish is required. Outdoor, a weather-resistant protective finish is to be applied. The recommended protective finish is WB Armaflex; however, other compatible finish systems are not ruled out. SPECIFICATION COMPLIANCE AP Armaflex developed to meet: ASTM C 534, Type II -- Sheet, Grade 1 ASTM C 1534 ASTM E 84 NFPA 255 UL 723 CAN/ULC-S102 UL 94 5V-A, V-0, File E 55798 NFPA 90A, 90B ASTM D 1056, 2B1 MIL-P-15280J, FORM S MIL-C-3133C (MIL STD 670B), Grade SBE 3 MEA 107-89-M City of Los Angeles -- RR 7642 CGSB CAN 2-51.40-M80 FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: info.us@armacell.com. Website: www.armacell.com AP ARMAFLEX SHEET AND ROLL AND SELF-ADHERING SHEET AND ROLL INSULATION AVERAGE PHYSICAL PROPERTIES Approved by Factory Mutual Approvals to meet or exceed key property values PHYSICAL PROPERTIES Thermal conductivity, Btu • in./h • ft2 • °F (W/mK) 75°F mean temp (24°C) 90°F mean temp (32°C) TEST METHOD 0.27 (0.039) 0.276 (0.040) ASTM C 177 or C 518 Water vapor permeability, perm-in. [Kg/(s•m•Pa)] 0.08 (1.16 x 10-13) ASTM E 96 Procedure A Water absorption, % by volume 0.2% ASTM C 209 Flame spread and smoke developed index through 1″ (25mm) 25/50 ASTM E 84 Ozone resistance GOOD — Upper use limit (See note 1) 220˚F (105˚C) AP Armaflex 180˚F (82°C) AP Armaflex SA (See note 3) — Lower use limit (See note 2) -70˚F (-57°C)* — Sizes – Sheet Width and length Thickness (nominal) Sizes – Roll Thickness (nominal) x Length Notes 1 When AP Armaflex Sheet is installed by adhering butt joints and seams only, the upper temperature limit is 220°F (105°C) using 520 or 520 BLV Adhesive. AP Armaflex Sheet adhered with complete adhesive coverage on flat or curved metal surfaces may be applied to surfaces that will operate as high as 180°F (82°C) using 520 or 520 BLV Adhesive. 2 At -20°F (-29°C), flexible AP Armaflex Insulation becomes hard and, as temperatures drop below -20°F (-29°C), will be increasingly brittle; however, this hardening characteristic does not affect thermal efficiency and resistance to water vapor permeability. For applications of -40°F to -70°F (-40°C to -57°C), contact Armacell. 3 AP Armaflex SA has an upper temperature use limit of +180°F (+82°C) * For applications of -40°F to -70°F (-40°C to -57°C), contact Armacell. 36″ x 48″ (.92m x1.22m) 1/8″, 1/4″, 3/8″, 1/2″, 3/4″, 1″, 1-1/2″ & 2″ (3, 6, 10, 13, 19, 25, 38 & 50mm) — 3/8″ x 100′ (10mm x 30.5m) 1/2″ x 70′ (13mm x 21.4m) 3/4″ x 50′ (19mm x 15.2m) 1″ x 35′ (25mm x 10.7m) 1-1/2″ x 25′ (38mm x 7.6m) 2″ x 18′ (50mm x 5.4m) — AP ARMAFLEX SHEET AND ROLL AND SELF-ADHERING SHEET AND ROLL INSULATION THICKNESS RECOMMENDATIONS THICKNESS RECOMMENDATIONS FOR CONTROLLING OUTER INSULATION SURFACE SWEATING DUCTS–TANKS–VESSELS–EQUIPMENT METAL-SURFACE TEMPERATURE 50°F (10°C) 35°F (2°C) 0°F (–18°C) BASED ON NORMAL DESIGN CONDITIONS AP Armaflex in the thicknesses noted and within the specified temperature ranges will control outer insulation surface condensation indoors under normal design conditions, a maximum severity of 85°F (29°C) and 70% RH. Armacell research and field experience indicate that indoor conditions anywhere in the United States seldom exceed this degree of severity. Nom 3/8″ (10mm) Nom 3/4″ (19mm) Nom 1-1/2″ (38mm) BASED ON MILD DESIGN CONDITIONS AP Armaflex in the thicknesses noted and within the specified temperature ranges will control outer insulation surface condensation indoors under mild design conditions, a maximum severity of 80°F (27°C) and 50% RH. Typical of these conditions are most airconditioned spaces and arid climates. Nom 1/8″ (3mm) Nom 1/4″ (6mm) Nom 1/2″ (13mm) BASED ON SEVERE DESIGN CONDITIONS AP Armaflex in the thicknesses noted and within the specified temperature ranges will control outer insulation surface condensation indoors under severe design conditions, a maximum severity of 90°F (32°C) and 80% RH. Typical of these conditions are indoor areas in which excessive moisture is introduced or in poorly ventilated confined areas where the temperature may be depressed below ambient. Nom 1″ (25mm) Nom 1-1/2″ (38mm) Nom 2″ (50mm) FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: info.us@armacell.com. Website: www.armacell.com 7 DUCT LINER HELPS PREVENT MOLD & MILDEW PATENTED MEETS NFPA 90A AND 90B HOSPITAL GRADE DESCRIPTION AP Armaflex SA is a black flexible elastomeric thermal insulation with a self-adhering backing. It is a closed-cell elastomeric foam that can reduce or eliminate conditions amplifying biological contamination and bioaerosols in commercial air systems. Engineered to control condensation, AP Armaflex SA has an inherent vapor retarder and requires no additional mastics or coatings. It is nonwicking and has a very low rate of water absorption. It continues to prevent water infiltration even after incidental mechanical abuse. The surface of the insulation is smooth, so that dirt and debris that may enter the air stream tend not to accumulate. The surface is durable and erosion-resistant. AP Armaflex SA is also cleanable and washable, providing a basis for continuing system hygiene. With its self-adhering backing, AP Armaflex SA is fast and easy to install and requires no mechanical fasteners in systems operating at 4,000 FPM (20.3 m/second) or below. The expanded closed-cell structure of Armaflex makes it an efficient insulation. It is mnufactured without the use of CFC’s, HCFC’s. It is also formaldehyde free, fiber free, dust free and resists mold and mildew. AP Armaflex SA Duct Liner is supplied in self-adhering sheets 36″ x 48″ (.915 m x 1.22 m), in nominal wall thicknesses of 3/8″, 1/2″, 3/4″ and 1″ (10, 13, 19 and 25 mm). Acoustical performance is comparable to half-inch thick fiberglass insulation. The product is approved through continuing supervision by Factory Mutual Approvals. USES AP Armaflex SA Duct Liner is a suitable replacement for traditional duct liner in air handlers, VAV units, ducts, and other air system components requiring condensation control and moisture and damage resistance. It meets the requirements of NFPA 90A, NFPA 90B for Duct Coverings and Linings and UL 181. TECHNICAL DATA PHYSICAL PROPERTIES TEST METHOD Thermal Conductivity BTU-in/hr • sq.ft • °F (W/mK) 75°F mean temperature (24°C) 90°F mean temperature (32°C) 0.27 (0.039) 0.276 (0.040) ASTM C 177 or C 518 Water Vapor Permeability Perm-inch [Kg/(s m Pa)] 0.08 [1.16 x 10-13] ASTM E 96 Procedure A Water Absorption, % by volume 0.2 ASTM C 209 Flame spread and Smoke developed index 1 Through1″ (25 mm) 25/50 ASTM E 84 CAN ULC S-102 ALCOHOL The temperature of the air Prepare surface by cleaning and of the insulation should with appropriate cleaner. be between 40°F (4°C) and Measure. 100°F (38°C) at the time of installation. Surface to be covered must be clean and free of any loose materials such as rust. Cut with sharp knife. Upper Use Temperature Limit, 2 180°F (82°C) Lower Use Temperature Limit, 3 -58°F (-50°C) Microbial Growth No Growth Erosion Resistance Does not break away, flake off or show ASTM C 1071 evidence of delamination at velocities of 6,000 ft/min Corrosiveness Noncorrosive Peel back enough release liner to start. Odor Emissions Reach behind the Armaflex sheet and peel liner back while pressing the sheet to the surface. Remove the entire liner piece. ASTM C 665 No objectionable odors ASTM C 665 Density, typical range, lbs/ft Square off sheet along an edge or corner. Press the sheet to the surface taking care not to trap any air. ASTM G 21 (Fungal), ASTM G 22 (Bacterial) ASTM C 1338 4 3.0 -- 6.0 ASTM D 1662 or ASTM D 1667 Notes 1 AP/Armaflex SA Duct Liner has a flame spread index of less than 25 and a smoke developed index of less than 50 for all thicknesses up to and including 1″ (25mm) when tested according to ASTM E 84 and CAN ULC S-102. Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. 2 Withstands temperature of 250°F (121°C) when tested according to ASTM C 411. "Test Method for Surface Performance of HighTemperature Insulations". At this temperature, AP/Armaflex SA Duct Liner insulation shows no evidence of flaming, glowing, smoldering, delamination, melting or insulation collapse. Although this insulation will withstand high temperatures, continuous use temperature should be limited to 180°F (82°C) 3 At -20°F (-29°C) flexible Armaflex insulation becomes hard and as temperatures drop below -20°F (-29°C), will be increasingly brittle; however, this hardening characteristic does not affect thermal efficiency or water vapor permeability. 4 Reference Only Sound Absorption Coefficients at Frequency Thickness 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC† 3/4″ (19mm) 0.04 0.07 0.16 0.69 0.18 0.25 0.30 1″ (25 mm) 0.00 0.08 0.32 0.55 0.23 0.21 0.30 † ASTM C 423 with ASTM E 795 Type “A” Mounting Sound Transmission Class (STC) 1/4" Press firmly. Butt joints require the use of compression joints to prevent the possible opening of seams. Thickness STC Class 1/2″ (13 mm) 25 1″ (25 mm) 25 Test Method ASTM E90 8 FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: info.us@armacell.com. Website: www.armacell.com Products LAMINATED SHEET & ROLLS ArmaTuff 25 • The best choice for exceptional durability. The white laminate is a rugged thermoplastic rubber (TPR) membrane with a 25-year warranty against degradation due to ultraviolet radiation. With Armatuff 25, maintenance is practically eliminated, so the lifestyle costs are substantially reduced. The product also provides superior resistance to acid rain and chemicals. ArmaTuff White • Offers great durability and UV resistance, at a lower cost. The laminate is a foil and polymer composite, with an extra coating for resistance to both acid rain and chemicals. ArmaTuff 25 Maximum Durability ArmaTuff Sliver • The most economical option. Although there are other foil-faced insulations available, ArmaTuff Silver is the only one with genuine Armaflex. ArmaTuff is installed using Armaflex 520 or, where a low V.O.C. adhesive is required, use Armaflex 520 BLV Adhesive. Adhesives or with pre-applied pressure sensitive adhesive (PSA) for application to large, flat or curved metal surfaces such as ducts, vessels, very large pipes or tanks. The seams must be installed in compression and sealed with Armaflex 520 Adhesives. Cover the seam with Armatuff Seal Tape. ArmaTuff White Excellent Performance ArmaTuff Seal Tape Sizes Sheets Continuous Rolls ArmaTuff 25 36″ x 48″ (0.915 x 1.22m) 1″, 1-1/2″ and 2″ thickness with PSA only 48″ wide (1.22m) 2″, 4″, 6″ 1″, 1-1/2″ and 2″ thickness without PSA only ArmaTuff Silver, ArmaTuff White 36″ x 48″ (0.915 x 1.22m)* 1/2″, 3/4″, 1″, 1-1/2″ and 2″ thickness 48″ wide (1.22m)* 1″, 1-1/2″ and 2″ thickness ArmaTuff Silver Economical 2″, 4″, 6″ and 23-1/2″ * With or without PSA PHYSICAL DATA PHYSICAL PROPERTIES TEST METHOD Thermal Conductivity, Btu-in-hr-ft•F (W/mK) 75°F mean temperature (24°C) 90°F mean temperature (32°C) 0.27 (0.039) 0.276 (0.040) ASTM C 177 or C 518 Water Vapor Permeability, perm-inch [kg/(s m Pa)] 0.02 [2.9 x 10-14] ASTM E 96 Procedure A Water Absorption % by volume 0.2 ASTM C 209 Upper Use Temperature Limit 180°F (82°C) Lower Use Temperature Limit -70°F (-57°C) UltraViolet (UV) Resistance Excellent Chemical Resistance ArmaTuff 25, ArmaTuff White ArmaTuff Silver Excellent Good Weatherability ArmaTuff 25, ArmaTuff White ArmaTuff Silver Excellent Good Durability ArmaTuff 25 ArmaTuff Silver, ArmaTuff White Excellent Good Microbial Growth No Growth ASTM G 21 (Fungal) ASTM G 22 (Bacterial) 3.0 - 6.0 ASTM D 1622 or ASTM D 1667 Density, typical range 3 ,lbs/ft 3 Installation 1. Always prepare surface by cleaning with denatured alcohol. 2. Insulate sides first. Apply thin, uniform coat of Armaflex 520 or 520 BLV Adhesive. 3. Roll thin coat of 520 or 520 BLV Adhesive to insulation. 4. Position carefully and apply ArmaTuff. Contact adhesive bonds instantly. 5. Apply ArmaTuff to top surface, overlapping the side pieces. 6. Seal and protect exposed edges and seams with ArmaTuff Seal Tape. QUV Chamber ASTM D 471 1 At -20°F (-29°C) flexible Armaflex insulation becomes hard and, as temperatures drop below -20°F (-29°C), will be increasingly brittle; however, this hardening characteristic does not affect thermal efficiency or water vapor permeability. 2 For reference only. FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: info.us@armacell.com. Website: www.armacell.com 9 PIPE INSULATION AND PIPE INSULATION QUICK & COST EFFECTIVE DESCRIPTION Tubolit and Tubolit Self-Seal Pipe Insulations are 25/50-rated flexible closed-cell black polyolefin/polyethylene pipe insulations, supplied as semi-slit or self-seal, in nominal wall thicknesses of 3/8″, 1/2″, 3/4″, and 1″ (10, 13, 19 and 25 mm), in the most frequently specified sizes. Tubolit is expanded without the use of CFC’s, HCF’s or HCFCs. It is also formaldehyde free, dust free, fiber free and resists mold and mildew. USES Tubolit Pipe Insulations are particularly effective for cost-efficient thermal insulation of domestic heating and plumbing lines. The recommended temperature usage range for Tubolit Insulations 0°F to +180°F (–17°C to + 82°C). As tested by ASTM E 84, “Method of Test for Surface Burning Characteristics of Building Materials,” Tubolit insulations through 1″ wall have a flame-spread index of less than 25 and a smoke-developed index of less than 50. Tubolit Self-Seal Insulation is snapped over new or existing pipework. Both install with simple hand tools and Armaflex 520 Adhesive or, where a low V.O.C. adhesive is required, Armaflex 520 BLV Adhesive. Butt joints should be sealed with either 520 or 520 BLV Adhesive. 520 Adhesives are contact adhesives; therefore, in all cases, both surfaces to be joined are coated with adhesive. Seams can be sealed with 520 or 520 BLV Adhesive. Tubolit and Tubolit SS must be protected from direct sunlight exposure and weather elements and must be protected when installed outdoors with weather-resistant jacketing or WB Armaflex Finish. SPECIFICATION COMPLIANCE ASTM C1427-Tubolit MEA 6-02M APPLICATIONS Tubolit Pipe Insulation in tubular form is easy to sleeve over new pipework, or cut longitudinally to snap over existing pipework. TECHNICAL DATA AVERAGE PHYSICAL PROPERTIES (See Note 1) Thermal conductivity, Btu • in/h • ft2 °F (W/mK) 75° (24°C) mean temp TEST METHOD 0.25 (0.036) ASTM C 177 or C 518 Water vapor transmission, perm-in [kg/(s•m•Pa)] 0.02 (2.9 x 10-14) ASTM E 96 Procedure A Flame spread and smoke developed index through 1″ thicknesses (see note 2) 25/50 ASTM E 84 Density, lbs/ft3 (Kg/m3) 2 (32) ASTM D 1622 3 Ozone resistance GOOD Upper use limit Tubolit 200°F (93°C) Tubolit SS 180°F (82°C) Lower use limit -200 of (-129°C) Sizes Wall thickness (nominal) Inside diameter, tubular form Length of sections, tubular form 3/8″, 1/2″, 3/4″ and 1″ (10, 13, 19, 25 mm) 3/8″ ID to 4″ IPS (10 mm ID to 114 mm) 6′ (1.83 m) NOTES 1 Average values are not to be used for writing material specifications. Contact Armacell for specification ranges. 10 2 See Armacell Info-Services #008 and #022, and “Fire Performance: Differences Between Elastomeric and Polyethylene Insulations.” See Armacell Info-Service #010 for details. 3 For reference only. FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: info.us@armacell.com. Website: www.armacell.com INSULATION PIPE HANGERS DESCRIPTION Armafix Insulation Pipe Hangers are quick, innovative alternatives to traditional block and dowel pipe supports. The engineered, foam-to-foam solutions provide optimum load bearing while protecting against thickness compression and condensation gaps that can compromise system integrity. USES Armafix is used to support insulated pipes with pre-insulated hangers that retard heat gain and control condensation drip from cold-water plumbing, chilled-water and refrigeration lines. It is engineered from Armaflex or NH/Armaflex insulation, with polyurethane inserts 30mils thick and aluminum (IPH) or stainless steel (NPH) jacket. It is single-piece construction, selfadhesive closure with exclusive foam-tofoam bond. Armafix (IPH) pipe hangers are available in nominal 3/4″ and 1″ wall thicknesses with ID’s ranging from 3/8″ ID to 8″ IPS. Also available in nominal 1/2″ wall thickness by special order. Armaflex NPH: NH/Armaflex nonhalogen insulation formulation available in 3/4″ nominal wall thickness with ID’s ranging from 3/8″ ID to 8″ IPS. Armaflex insulation’s thermal conductivity resistance to moisture vapor flow (WVT) and closed cell structure provide for total system integrity. EFFICIENT, FASTER SUPPORT APPLICATION Armafix longitudinal seams are selfadhering. The ends are easily sealed with Armaflex 520 Adhesive or, where a low V.O.C. adhesive is required, Armaflex 520 BLV Adhesive to ensure a completely sealed system. For some applications, saddles are recommended. To minimize the movement of Armafix, it is recommended that a pair of non-skid pads, be adhered to the clamps. In addition to prevent loosening of the clamps, use of an anti-vibratory fastener, such as a nylon looking nut, is also recommended. Painted aluminum or stainless steel jacket Armaflex Supports made of CFC-free PUR/PIP Selfclosure Painted aluminum or stainless steel jacket TECHNICAL DATA PHYSICAL PROPERTIES TEST METHOD Thermal Conductivity BTU-in/hr • sq.ft. • °F (W/mK) 75°F mean temperature (24 °C) 90°F mean temperature (32 °C) 0.27 (0.039) 0.276 (0.040) Water Vapor Permeability Perm-inch [Kg/(s m Pa)] (IPH) 0.08 [1.16 x 10-13] (NPH) 0.05 [7.25 x 10-14] ASTM E 96 Procedure A Water Absorption, % by volume 0.2 ASTM C 209 Upper Use Temperature Limit 220 °F (105 °C) Lower Use Temperature Limit 1 Density, typical range 2 , lbs/ft3 ASTM C 177 or C 518 -58 °F (-50 °C) 8.0 -- 11.0 ASTM D 1662 or ASTM D 1667 Notes 1 At -20 °F (-29 °C) flexible Armaflex insulation becomes hard and as temperatures drop below -20 °F (-29 °C), will be increasingly brittle; however, this hardening characteristic does not affect thermal efficiency or water vapor permeability. 2 Reference only. Easy Application on Clevis (saddle) Application with insulation Clamp (Friction fit) FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: info.us@armacell.com. Website: www.armacell.com 11 Insulation Products for Mechanical Systems 520 & 520 BLV ADHESIVES FINISH INSULATION TAPE Armaflex® 520 Adhesive is an air-drying contact adhesive that is excellent for joining seams and butt joints of AP and NH Armaflex Pipe and Sheet Insulation and Tubolit Pipe Insulation or, where a low V.O.C. adhesive is required, use Armaflex 520 BLV Adhesive. WB/Armaflex Finish is a white water-based latex enamel for use over all forms of Armaflex Insulations. It provides a protective semi-gloss finish for both indoor and outdoor applications. WB Armaflex Finish brushes or rolls on easily. Its water base formulation makes it fast-drying without solvent fumes. Cleans up with soap and warm water. WB Armaflex Finish is supplied in gallon and quart containers. AP/Armaflex Insulation Tape is made of the same high-quality elastomeric thermal insulation material as AP Armaflex Insulation. The tape is supplied in convenient strip form, 2″ (50 mm) wide, 30′ (9.1 m) long and 1/8″ (3 mm) thick. AP Armaflex Insulation Tape provides a fast, easy method for insulating pipes and fittings. It is used to control condensation drip on domestic cold-water, chilled water, and other cold piping and fittings and to reduce heat loss when applied to hot-water lines that will operate up to 180°F (82°C). 520 Adhesive meets Military Specification MIL-A-24179A and Amend-2 as Type II, Class 1. Both 520 Adhesives when dried to a film meet flammability classification requirements of codes and specifications of less than 25 for flame spread index and less than 50 for smoke developed index when tested by ASTM E 84 Test Method. ARMACELL LLC 7600 Oakwood Street Extension P. O. Box 1038 Mebane, NC 27302 WB Armaflex Finish adheres to clean Armaflex surfaces and dries to a pliant coating. Up to 400 square feet (37 square meters) per gallon coverage per single brush coat depending on temperature and location. Indoors, it provides a clean white protective finish, which is impervious to moisture. Outdoors, its special properties make it exceptionally durable and weather resistant to ultraviolet (UV) and ozone. Like typical paint coatings, WB Armaflex finish requires routine maintenance Outdoor surfaces should be recoated every 2-4 years. Meets Flammability classification requirements of codes and specifications of less than 25 for flame spread index and less than 50 for smoke developed index when tested by ASTM E 84 test method. Armacell provides all information contained in this catalog as a technical service. To the extent the information is derived from sources other than Armacell, Armacell is substantially, if not wholly, relying upon the other source(s) to provide accurate information. Information provided as a result of Armacell’s own technical analysis and testing is accurate to the extent of our knowledge and ability, as of date of printing, using effective standardized methods and procedures. Each user of these products, or information, should perform their own tests to determine the safety, fitness and suitability of the products or combination of products, for any foreseeable purposes, applications and uses by the user and by any third party to which the user may convey the products. Since Armacell cannot control the end use of these products, Armacell does not guarantee that the user will obtain the same results as published in this document.The data and information are provided as a technical service and are subject to change without notice. TEL. 919 304-3846 FAX 919 304-3847 E-MAIL info.us@armacell.com INTERNET www.armacell.com 999S 001S 05 04 NA NA © 2004 Armacell LLC Printed in United States of America