Monodraught Data Cards
Transcription
Monodraught Data Cards
Product Cards April 2013 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com Content INFORMATION About Monodraught Terms & Conditions Guarantee 4 6 10 NATURAL DAYLIGHT SYSTEMS SUNPIPE® SUNPIPE 230, 300, 450 SUNPIPE 530, 750, 1000 Square SUNPIPE 300, 450 12 13 17 20 SUNCATCHER® ABS SUNCATCHER 350, 550 23 24 SOLA-VENT® SOLA-VENT 230, 300 27 28 NATURAL VENTILATION SYSTEMS WINDCATCHER X-AIR® WINDCATCHER X-AIR SOLA-BOOST X-AIR 31 32 39 VENTSAIR® VENTSAIR Roof Mounted Terminals 42 43 WINDCATCHER® WINDCATCHER CLASSIC (Square) WINDCATCHER CLASSIC (Circular) WINDCATCHER CLASSIC RCT (Rectangular) WINDCATCHER CLASSIC OVL (Oval) WINDCATCHER CLASSIC Bespoke (BSK) WINDCATCHER HERITAGE 45 46 49 51 52 53 54 SOLA-BOOST® SOLA-BOOST CLASSIC (Square) TRILAYER WEATHER PROTECTION (Square) 56 57 59 Page 2 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com NATURAL COOLING SYSTEMS COOL-PHASE® 60 61 OTHERS HEAT HARVESTER® 66 66 CONTROL SYSTEMS iNVent (IN0031) WINDCATCHER CONTROLLER (IN0001 and IN0002) SOLA-BOOST CONTROLLER (IN0003 and IN0004) RAIN SENSOR KIT (IN0043, IN0042, IN0040) ROOM CO2 AND TEMPERATURE SENSOR (IN0081) ROOM TEMPERATURE SENSOR (IN0045) EXTERNAL TEMPERATURE SENSOR (IN0048) 68 69 72 74 76 78 80 82 BUILDING SIMULATION DAYLIGHT SIMULATION THERMAL MODELLING 84 85 87 Page 3 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com Information About Monodraught We have taken our own steps to reduce and minimise our direct impact on the use of energy, waste and water, and have also taken steps to make indirect impact on our environment with respect to procurement and influencing Clients’ views on low energy. Monodraught Ltd seeks to explore, develop and create innovative low energy concepts and building services solutions in response to the need to reduce energy consumption of buildings and for their users to reduce energy costs. Accordingly, by maximising natural available energy from the wind and the sun, Monodraught’s products help their users reduce their energy consumption, costs, and carbon footprint. Monodraught’s extensive R&D department is key to the successful development of products such as the WINDCATCHER® natural ventilation systems that provides a controlled quantity of fresh air into a room from roof level, whatever the wind’s direction, and without mechanical assistance; the SOLA‑BOOST® solar assisted natural ventilation systems that uses the WINDCATCHER technology in coordination with a solar powered fan to guarantee additional ventilation on sunny days; and the SUNPIPE® natural daylight systems that delivers daylight to areas that windows cannot reach. The latest technology to benefit from this dedicated R&D resource is the range of PCM (phase change material) systems that provide extremely low energy consumption cooling and ventilation systems and provide a stable room temperature environment. Armed with all of these systems Monodraught can provide the optimum low energy solution to the client. • VISION STATEMENT: Harnessing nature to deliver exemplar sustainable indoor environments through innovation. • MISSION STATEMENT: Gaining customers for life by: Valuing our people, our products, and our service. • CE-MARKING / APPROVALS: Monodraught’s SUNPIPE System is classified within the following EU Directive:89/106/EEC and further conforms with the following EU Harmonized Standard : EN 1873:2995 Monodraught is accredited with Constructionline in addition to CHAS and Safecontractor Monodraught is also ISO 9001 and 14001 approved. • CLEANING / MAINTENANCE: Monodraught systems are all ‘low maintenance’. However an annual contract is offered to clients which covers routine periodic maintenance. • DELIVERY / CARRIAGE: Carriage paid on SUNPIPE systems applied to UK mainland deliveries 2 – 3 days from date of order. Overnight rush charge + £25. Overseas carriage charges on application. Carriage for Ventilation units upon design and quotation. Page 4 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com About Monodraught Since our inception in the UK in 1974, we have always sought to invent, explore and develop innovative products with visually appealing designs, which achieve an efficient contribution to the optimum enhancing of our natural resources. Monodraught Products make a major contribution to harnessing natural resources and energy efficient designs, to the ultimate environment benefit of building for the future. • PLANNING PERMISSION / BUILDING REGULATIONS, ETC: For the SUNPIPE systems you do not normally need to apply for planning permission, but it would be advised to check your local planning department prior to commencement of works. WINDCATCHER natural ventilation systems will require planning permission due to the aesthetic impact on the exterior of the building. Considerations will also need to be made to ensure each individual installation meets with Building Regulations. The requirements for ventilation, acoustic attenuation and thermal performance will need to be assessed. Monodraught can provide assistance in ensuring systems meet with requirements and systems can be tailored to suit each installation. • INSTALLATION: Monodraught offer an installation service if required, please contact Head Office for a quote. • TERMS & CONDITIONS: See Pg 6. • GUARANTEE: Monodraught offer a 10 Year Guarantee on most products (See Pg 10 for full details). Page 5 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com Terms & Conditions DEFINITIONS: In these Terms and Conditions of Trading: ‘Monodraught’ means Monodraught Ltd, registered office is at Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE, (Company No. 01163485). ‘Buyer’ means the person or firm who acquires the Goods under the Contract. ‘Conditions’ means these Terms and Conditions of Trading. ‘Contract’ means the contract between Monodraught and the Buyer for the supply of Goods. ‘Goods’ means any Goods sold by Monodraught to the Buyer and unless separately referred to, “Goods” includes any related or connected services associated with the supply, including any installation, design, fabrication or construction undertaken by Monodraught or its agents. “Order” means the Buyer’s order for the supply of Goods as set out in the Buyer’s purchase order form or written acceptance of Monodraught’s quotation as the case may be. 2. CONTRACT: The Buyer’s order constitutes an offer by the Buyer to purchase Goods from Monodraught in accordance with these Conditions. All Orders are accepted by Monodraught subject to the Goods being available. The Order shall only be deemed to be accepted when Monodraught issues a written acknowledgement of the Order at which point a Contract shall come into existence. These Conditions apply to the Contract to the exclusion of any other terms and conditions that the Buyer seeks to impose or incorporate, or which are implied by trade, custom, practice or course of dealing. Goods shall be supplied in accordance with Monodraught’s acknowledgement of order and cannot be cancelled, deferred or altered and shall not be subject to reduction or variation except by mutual agreement confirmed in writing by both parties and subject to agreement as to related costs. 3. PRICES: All prices quoted by Monodraught are valid for a period of six months from the date of a quotation or from the date of issue of price lists unless otherwise expressly stated in the quotation or price list. All prices are subject to Valued Added Tax at the current rate at the time of delivery. All prices quoted are net trade prices and shall not be subject to retention or net discount, unless specifically stated in a quotation or acknowledgement of order. Carriage prices shown in quotations are net prices and are not subject to any discount. 4. DELIVERY: Monodraught will use its reasonable endeavours to make deliveries of Goods on the date/s agreed but time of delivery shall not be of the essence and Monodraught shall not be liable for any delay in delivery for events of Force Majeure or matters which are the responsibility of the Buyer and shall not otherwise be liable for delay unless otherwise agreed in writing before delivery. 5. RISK AND INSURANCE: Risk in the Goods shall pass to the Buyer from the point of delivery to the Buyer’s address or other agreed place of delivery or on collection by the Buyer as appropriate, notwithstanding that property in the Goods may be retained by Monodraught in accordance with Clause 7. The Buyer shall be responsible for effecting its own insurance as appropriate from the date of delivery. Once the Goods have been delivered or installed the Buyer shall be responsible to fully protect them and keep them safe. 6. PAYMENT: Payment of any invoice shall become due on the date of Monodraught’s invoice. The final date for payment shall be 30 days after the relevant invoice becomes due. Amounts unpaid beyond the final date for payment are payable with interest calculated at the rate of 8% over the base rate of the Bank of England applicable at the final date for payment until Page 6 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com Terms & Conditions 1. payment is received in full. Within 5 days of an invoice becoming due, the Buyer shall notify Monodraught of the sum that the Buyer considers to be due at the payment due date and the basis on which that sum is calculated (‘payment notice’). Not less than 7 days before the final date for payment, the Buyer may give notice if it intends to pay less than the notified sum, specifying the sum considered to be due and the basis on which that sum is calculated (‘pay less notice’). Unless the Buyer gives a pay less notice then it shall pay the sum in the payment notice (or in the absence of a payment notice then the sum in Monodraught’s invoice) on or before the final date for payment of the invoice. Where part delivery or part service work is carried out, a payment on account will be payable based on Monodraught’s invoice for the relevant amount. The Buyer shall not be entitled to apply any set off against any sums owing to Monodraught under the Contract any other sums owing to Monodraught. If the Buyer fails to make any payment by the final date for payment then without prejudice to any other rights Monodraught reserves the right to; suspend some or all obligations under the Contract, or terminate the Contract, or take down and retrieve any Goods previously installed. 7. RETENTION OF TITLE: Title in the Goods shall remain with Monodraught until full payment for the Goods has been received. Until such time, the Buyer shall keep the Goods free from any charge, lien or other encumbrance whatsoever and identifiable as the property of Monodraught. Until payment in full for the Goods has been received, Monodraught may at any time require the Goods to be returned to it and if such requirement is not forthwith complied with, it may retake possession of the Goods and for such purposes is irrevocably authorised to enter upon any premises (whether or not occupied by the Buyer) and retrieve the Goods. 8. WARRANTY OF QUALITY: Monodraught warrants that from the date of shipment of the Goods that the Goods shall, conform with the specification set out in Monodraught’s quotation or acknowledgement of order or if there is no such specification, the Goods will comply with reasonable standards of quality and will otherwise be reasonably free from material defects in design, materials and workmanship when under normal use. This warranty shall apply for; 10 years for natural ventilation & natural day lighting products, 5 years for natural cooling products. The solar driven, mechanical and electrical components of such Goods shall have a warranty period of 1 year. Whilst all product information is given in good faith the use or application of the Goods is outside the control of Monodraught and accordingly Monodraught gives no warranty as to the fitness of the Goods for any particular purpose and any implied warranty or condition (statutory or otherwise) is excluded insofar as such exclusion is permitted by law, including in regard to the suitability of the Goods for the structure where the Goods are to be installed. It shall be the responsibility of the Buyer to obtain its own professional guidance on such matters. The Buyer will not be entitled to return Goods to Monodraught unless Monodraught gives written consent and in which case the Buyer shall pay a restocking charge amounting to 15% of the purchase price for the Goods. The Buyer shall make no claim against Monodraught in relation to defects in the Goods (or shortages in delivery) unless the Buyer has notified Monodraught in writing of the same within 48 hours of delivery. The Buyer must notify Monodraught directly about any such claim (including packaging) relating to carriage. In the event of a claim, Monodraught must be given a reasonable opportunity of examining the Goods. If asked to do so the Buyer shall return the Goods to Monodraught at the Buyer’s cost. Monodraught at its option, may repair or replace defective Goods, or refund the price of the relevant Goods. Page 7 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com Monodraught shall be under no liability in respect of defects arising from; the acts or omissions of persons other than Monodraught or its authorised personnel or agents, including but not limited to damage in transit, repairs, modifications or additions made to the Goods by the end-user or any other third party; failure to perform appropriate maintenance; continued use of the Goods after they exhibit signs of any defect or malfunction; carelessness, mishandling, wear and tear, vandalism or unforeseen events; use of the Goods contrary to Monodraught’s recommendations; any failure or defect in related products or systems which the Goods have been integrated with, operate with or are dependent on; defects in materials or workmanship which are the result of installation by persons other than Monodraught. Except as set out in these Conditions, all warranties, conditions and other terms implied by statute or common law are, to the fullest extent permitted by law, excluded from the Contract. Monodraught will at its sole discretion undertake for the Buyer or any end user of the Goods, the repair or replacement of the relevant Goods at its own cost and so that the Goods conform to the Contract. If however in Monodraught’s reasonable opinion, the end-user is unable to establish a failure on Monodraught to comply with the Contract then the Buyer shall be responsible for all costs and expenses incurred by Monodraught in investigating any alleged breach. 9. FORCE MAJEURE: Notwithstanding any agreement to the contrary, any delivery may be totally or partially suspended by Monodraught as a result in delay in manufacture, supply or delivery arising from acts of God, unforeseeable circumstances, acts of Government or local authority, war, revolution, fires, ice, strikes, industrial disputes, inability to obtain necessary and proper materials, facilities, transportation or labour or any other cause beyond Monodraught’s control. Any Goods, the delivery of which has not been totally or partially suspended shall be accepted by the Buyer as soon as it is reasonably practicable after the reason for delay has abated. 10. TERMINATION: Either party may terminate the Contract with immediate effect by giving written notice to the other party if; the other party commits a material breach of its obligations under the Contract and fails to remedy that breach within 14 days after receipt of the written notice; or the other party suspends, or threatens to suspend, payment of its debts or is unable to pay its debts as they fall due or admits inability to pay its debts or; a petition is filed, a notice is given, a resolution is passed, or an order is made, for or in connection with the winding up or bankruptcy of the other party; an application is made to court, or an order is made, for the appointment of an administrator; or a receiver is appointed over the assets of the other party; or any event occurs, or proceeding is taken, with respect to the other party that has an effect equivalent or similar to any of the aforementioned events. On termination of the Contract for any reason; the Buyer shall immediately pay all of Monodraught shall not be liable for any loss in any form arising from or related to snow or water ingress into or through the Goods, unless such liability has been accepted by Monodraught in writing. Nothing in these Conditions shall limit or exclude Monodraught’s liability for, death or personal injury caused by its negligence, or the negligence of its employees, agents or subcontractors; fraud or fraudulent misrepresentation; or breach of relevant statutory provisions, subject to which Monodraught shall under no circumstances whatever be liable, whether in contract, tort (including negligence), breach of statutory duty, or otherwise, for any loss of profit, or any indirect or consequential loss arising under or in connection with the Contract; and its total liability to the Buyer in respect of all other losses arising under or in connection with the Contract, whether in contract, tort (including negligence), breach of statutory duty, or otherwise, shall in no circumstances exceed the value of the Goods and after taking into account what is fair and reasonable allowing for the relative contributions to any loss suffered by the Buyer of Monodraught and other parties who have entered into any arrangements (contractual or otherwise) with the Buyer in connection with the Goods or related project or works. Page 8 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com Monodraught’s outstanding unpaid invoices and interest and shall return all of the Goods which have not been fully paid for. If the Customer fails to do so, then the Supplier may enter the Customer’s premises and take possession of them. Until they have been returned, the Customer shall be solely responsible for their safe keeping and will not use them for any purpose not connected with the Contract. The accrued rights and remedies of the parties as at termination shall not be affected, including the right to claim damages in respect of any breach of the Contract which existed at or before the date of termination or expiry; and clauses which expressly or by implication have effect after termination shall continue in full force and effect. 11. LAW: The Contract shall be subject to English law and the English Courts. A person who is not a party to the Contract shall not have any rights under or in connection with it. Either party may refer a dispute arising under the Contract to adjudication at any time under Part I of the Scheme for Construction Contracts (England and Wales) Regulations, which Part shall take effect as if it was incorporated into this clause. Monodraught Limited 1st November 2012 These Terms and Conditions supersede all previous Terms and Conditions Page 9 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com Guarantee “Monodraught” Means Monodraught Limited, Halifax House, Cressex Business Park, High Wycombe, Bucks HP12 3SE. “Goods” Monodraught’s current WINDCATCHER® natural ventilation systems range of goods. “Registration Documents” Means the registration documents accompanying this Guarantee. 1. Commencement of the Guarantee: The Guarantee period shall run from the time the Goods are delivered to the End-user but shall only take effect when the End-user registers the Guarantee by returning the Registration Documents to Monodraught. 2. Extent of the Guarantee: Monodraught guarantees its Goods to be reasonably free from defects in materials and workmanship when under normal use. All other warranties and representations, whether express or implied, are excluded to the fullest extent permitted by law. This guarantee shall apply for a period of 10 years (5 years for COOL-PHASE) other than for solar driven and mechanical and electrical components of such Goods for which the period of guarantee shall be 1 year. The Guarantee shall not apply and Monodraught shall be under no liability in respect of any defect in the Goods arising from: 2.1 the acts or omissions of persons other than Monodraught or its authorised personnel or agents, including but not limited to damage in transit, repairs, modifications or additions made to the Goods by the End-user or any third party; 2.2 failure to perform appropriate maintenance; 2.3 any continued use of the Goods after they exhibit signs of any defect or malfunction; 2.4 carelessness, mishandling, wear and tear, vandalism or unforeseen events; 2.5 use of the Goods contrary to Monodraught’s recommendations; 2.6 any failure or defect in related products or systems which the Goods have been integrated with, operate with or are dependent on; 2.7 defects in materials or workmanship which are the result of installation by others than Monodraught. 3. Repair or Replacement under the Guarantee: Monodraught will at Monodraught’s sole discretion discharge in full any liability to the End-user under this Guarantee by repairing or replacing the relevant Goods (or any part thereof) at no charge so that the relevant Goods conforms to such Guarantee, and the Guarantee will continue for the remainder of the period set out in Clause 2. If in Monodraught’s sole opinion, the End-user is unable to establish breach of the guarantee in Clause 2, the End-user shall be responsible for all costs and expenses incurred by Monodraught in investigating such alleged breach. 4. Data Protection: Monodraught shall comply at all times with its obligations under the Data Protection Acts 1998 and any other legislation relating to the protection of personal data. Page 10 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com Guarantee “End-user” Means the natural or legal person who owns the Goods and who has not acquired them with a view to re-selling or installing them in the course of business. 5. Notice: No notice to be given to Monodraught shall be effective unless given in writing by recorded delivery post which will be deemed received two (2) business days after posting. 6. Miscellaneous: 6.1 Monodraught may perform any of its obligations or exercise any of its rights under this Guarantee by itself or through any Monodraught subsidiary or holding company or any subsidiary of any such holding company. 6.2 Subject to Clause 6.1, this Guarantee is not intended by the parties to give rise to any right which is enforceable by any third party by virtue of the Contracts (Rights of Third Parties) Act 1999. 6.3 This Guarantee is subject to English Law and the English Courts shall have exclusive jurisdiction over any dispute arising out of or in connection with this Guarantee. 6.4 This Guarantee does not and will not affect your Statutory Rights as a consumer. Page 11 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com SUNPIPE® Natural Daylight Systems Page 12 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com Domestic SUNPIPE systems SUNPIPE 230, 300, 450 Sizes available: 230, 300, 450 Monodraught’s SUNPIPE® natural daylight system can be installed on almost any roof type and directs sunlight into a room. The SUNPIPE collects daylight using a patented Diamond dome, then the MIRO-SILVER® finish aluminium tube transfers the light to ceiling level before the ceiling diffuser evenly distributes the light around the room without glare. SUNPIPES are suited to almost any application, and have been installed anywhere from residential bedrooms to the Olympic Handball Arena in London. TECHNICAL DETAILS • • MATERIAL: »» Top Dome 4 mm UV stabilised polycarbonate (also avilable in 4 mm thick acrylic). »» SUNPIPE MIRO-SILVER® finish Aluminium. »» Upstand to suit roof type. Available in ABS, Galvanised Steel or GRP. Diamond top dome Condensation seal ABS flashing plate for slate roof ABS undercloak roofing felt support PERFORMANCE: »» 230: 2160 lumen output in full summer sun (105 Klux). 610 mm long connecting piece »» 300: 4460 lumen output in full summer sun (105 Klux). »» 450: 10770 lumen output in full summer sun (105 Klux). »» Typical U Value 2.18 W/m²K based on a 1.5 m 45° adjustable length of SUNPIPE and double skin diffuser. elbow • • OPTIONS: »» 610 mm (2ft) extension lengths 30°/45° adjustable elbows. »» Motorised light shut off Damper. »» Security Bars. »» Integral Electric Light Kit for night use. »» Fire Collar. »» Soundguard, Fireguard, Double Glazed and Square Ceiling Diffusers. DIMENSIONS 230: »» 230 mm Dia SUNPIPE. »» 250 mm Dia roof and ceiling opening required. • DIMENSIONS 300: »» 305 mm Dia SUNPIPE. »» 320 mm Dia roof and ceiling opening required. • DIMENSIONS 450: »» 457 mm Dia SUNPIPE. »» 470 mm Dia roof and ceiling opening required. 610 mm standard SUNPIPE length Plywood backing plate/template Bell end slip length ceiling extension Fixing ring Clear or opal ceiling diffuser Push-on diffuser trim in white acrylic capped ABS as standard Page 13 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com SUNPIPE 230, 300, 450 GENERAL DESCRIPTION LIGHT OUTPUT PERFORMANCE Data for a typical flat roof application measured 1.5 m below SUNPIPE Diffuser Dia 230 (9”) 300 (12”) 450 (18”) Full Summer Sun 105 klux Lux Value Lumen Output of the system 360 2160 760 4460 1820 10770 Overcast Summer 45 klux Lux Value Lumen Output of the system 170 1045 330 1940 750 4410 Overcast Winter Lux Value 65 130 300 Lumen Output of the system 670 760 1768 Area Lit 7.5 m² 14 m² 22 m² PRODUCT OPTIONS 1. 1. Security Bars Provides extra security by means of integrating stainless steel security bars which do not impact the light output of the system. 2. Fire Collar Intumescent ‘Fire Choke’ Fire collars can be integrated within the system to prevent the spread of smoke and fire through the roof to give up to 2 hours protection. 3. 3. Integral Electric Lighting Kit Includes a 50 W extra low voltage Halogen light fitting and transformer to provide light outside of daylight hours. 4. Fireguard Fireguard ceiling diffusers can be used in place of the standard polycarbonate diffusers to provide up to 1 hour fire resistance. 5. 2. 4. 5. Soundguard Soundguard ceiling diffusers can be used in place of the standard polycarbonate diffusers to provide sound attenuation of up to 37dBa. 6. Motorised Shut off Features a butterfly light shut-off damper controlled by a 230V motorised actuator for use in areas such as Lecture Theatres, Conference Halls etc 6. 7. 7. Stainless Steel Effect 8. Double Glazed and Square SUNPIPEs are supplied with white ABS trim as standard Ceiling Diffusers are also but can be available in different finishes to suit their décor. SUNPIPE options. Note: Fireguard and Soundguard for 230 mm dia SUNPIPE systems require a ceiling opening of 280 mm dia; for 305 mm dia SUNPIPE systems, ceiling opening is 350 mm dia and for 457 mm dia SUNPIPE systems, ceiling opening is 505 mm dia. Page 14 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com PRODUCT VARIANTS SUNPIPE for Horizontal and Basement Applications The SUNPIPE natural daylight systems can also be used in horizontal and basement applications. THERMAL PERFORMANCE U-VALUES (W/m2.K) Length Dia 230 (9”) 300 (12”) 450 (18”) 0.5 m 1.57 1.62 1.76 1m 1.46 1.52 1.68 2m 1.39 1.42 1.59 3m 1.34 1.38 1.54 4m NA 1.37 1.49 5m NA 1.36 1.46 TYPICAL USES • • • The 230 SUNPIPE system is typically used within small areas such as an en-suite. The 300 SUNPIPE system is the most popular domestic kit suitable for lighting most average sized rooms. The 450 SUNPIPE system is the largest domestic kit and would be suitable for lighting large open spaces. NBS SPECIFICATIONS SUNPIPE® SYSTEMS Monodraught’s SUNPIPE® natural daylight system can be installed on almost any roof type and directs sunlight into a room. The SUNPIPE collects daylight using a patented Diamond dome, then the MIRO-SILVER® finish aluminium tube transfers the light to a ceiling level before the ceiling diffuser evenly distributes the light around the room without glare. • FEATURES: »» Glazing details: Clear polycarbonate diamond dome with UV inhibitors, complete with brushed nylon condensation gasket. »» Lining: MIRO-SILVER® finish aluminium tube in 610 mm lengths. »» Ceiling diffuser: Prismatic, with white ceiling trim and 3 mm plywood. • ADVANTAGES: »» Generally no structural alterations required, easily fits between joists and rafters. »» Horizontal and basement applications are possible. »» No maintenance required. »» Top domes are self-cleaning due to their shape. A brushed nylon condensation seal eliminates condensation problems. Page 15 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com • STANDARDS: »» BS EN ISO 14001 and BS EN ISO 9001. »» The Fireguard ceiling diffuser has been tested to comply with BS 476-20: 1987. »» The fire choke collar has been fully tested to current British and European standards (test report TE 39902): • Size: 230, 300, 450. • Roof Terminal: »» UV-protected polycarbonate Diamond shaped dome OR »» Impact resistant acrylic Diamond shaped dome • Ceiling Diffuser: »» Polycarbonate prismatic diffuser • Accesories: »» Adjustable elbows »» Fire choke collar »» Fireguard diffuser »» Integral electric light kit »» Motorised light shut-off dampers »» Security fixings »» Soundguard diffuser • Ceiling Trim: »» White (as standard) »» Stainless steel effect • Roof Type: »» Bold rolled tile »» Felt »» Membrane »» Green roof kit »» Metal »» Pitched slate »» Plain Tile »» As Standard: • Flashing Type: (as standard) »» ABS - For pitched slate roofs »» ABS with weathering skirt - For pitched plain tiled roofs »» Code 4 lead - For pitched bold rolled tiled roofs »» Galvanised flashing - For flat roofs »» Extended galvanised flashing - For green/sedum roofs »» Options: Other bespoke arrangements are available. For sizing guidance or further details, please contact Monodraught Head Office. »» Approvals: mark : CHAS registered Page 16 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com Commercial SUNPIPE systems SUNPIPE 530, 750, 1000 TECHNICAL DETAILS • • • • MATERIAL: »» Top Dome 4mm UV stabilised polycarbonate (also available in 4 mm thick acrylic). »» SUNPIPE MIRO-SILVER® finish Aluminium. »» Upstand to suit roof type. Available in ABS, Galvanised Steel or GRP (for 530 systems). Diamond top dome Condensation seal ABS Collar PERFORMANCE: »» 530: 14995 lumen output in full summer sun (105 Klux). »» 750: 25568 lumen output in full summer sun (105 Klux). »» 1000: 45300 lumen output in full summer sun (105 Klux). »» Typical U Value 2.18 W/m²K based on a 1.5m length of SUNPIPE and double skin diffuser. OPTIONS: »» 610 mm (2ft) extension lengths. »» 30°/45° adjustable elbows (for 530mm systems), fixed elbows (for 750mm,1000mm systems) »» Motorised light shut off Damper. »» Security Bars. »» Fire Collar (for 530 systems). »» Soundguard, Fireguard, and Square Ceiling Diffusers (for 530 systems). »» Double Glazed diffusers. DIMENSIONS 750: »» 750 mm Dia SUNPIPE. »» 770 mm Dia roof and ceiling opening required. • DIMENSIONS 1000: »» 1000 mm Dia SUNPIPE. »» 1020 mm Dia roof and ceiling opening required. 610 mm standard SUNPIPE length Plywood backing plate/template Bell end slip length ceiling extension Fixing ring DIMENSIONS 530: »» 535 mm Dia SUNPIPE. »» 550 mm Dia roof and ceiling opening required. • Flashing plate (optional ABS, galvanised or lead) Clear or opal ceiling diffuser Push-on diffuser trim in white acrylic capped ABS as standard Page 17 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com SUNPIPE 530, 750, 1000 GENERAL DESCRIPTION Sizes available: 530, 750, 1000 Monodraught’s SUNPIPE® natural daylight system can be installed on almost any roof type and directs sunlight into a room. The SUNPIPE collects daylight using a patented Diamond dome, then the MIRO-SILVER® finish aluminium tube transfers the light to ceiling level before the ceiling diffuser evenly distributes the light around the room without glare. SUNPIPES are suited to almost any application, and have been installed anywhere from residential bedrooms to the Olympic Handball Arena in London. LIGHT OUTPUT PERFORMANCE Data for a typical flat roof application measured 1.5 m below SUNPIPE Diffuser Dia 530 (21”) 750 (29.5”) 1000 (39.5”) Full Summer Sun 105 klux Lux Value Lumen Output of the system 2530 14995 4350 25568 13630 45300 Overcast Summer 45 klux Lux Value Lumen Output of the system 1050 6265 1975 11620 3850 24650 Overcast Winter Lux Value 430 900 1425 Lumen Output of the system 2550 5300 8390 Area Lit 30 m² 50 m² 60 m² PRODUCT OPTIONS 1. 1. Security Bars Provides extra security by means of integrating stainless steel security bars which do not impact the light output of the system. 2. Fire Collar Intumescent ‘Fire Choke’ Fire collars can be integrated within the system to prevent the spread of smoke and fire through the roof to give up to 2 hours protection (only for 530). 3. 2. 3. Fireguard Fireguard ceiling diffusers can be used in place of the standard polycarbonate diffusers to provide up to 1 hour fire resistance (only for 530). 4. Motorised Shut off Features a butterfly light shut-off damper controlled by a 230V motorised actuator for use in areas such as Lecture Theatres, Conference Halls etc (for 530 and 750 systems only). 4. 5. 5. Soundguard Soundguard ceiling diffusers can be used in place of the standard polycarbonate diffusers to provide sound attenuation of up to 37dBa (only for 530). 6. Double Glazed and Square Ceiling Diffusers are also SUNPIPE options. Note: Fireguard and Soundguard for 535 mm dia SUNPIPE systems require a ceiling opening of 580 mm dia. THERMAL PERFORMANCE U-VALUES (W/m2.K) Length Dia 530 (9”) 750 (12”) 1000 (18”) 0.5 m 1.80 1.87 1.96 1m 1.73 1.82 1.88 2m 1.64 1.75 1.80 3m 1.58 1.70 1.74 4m 1.54 1.66 1.69 5m 1.51 1.63 1.66 TYPICAL USES • • • The 530 SUNPIPE: Used in large open spaces such as Large Office and dining areas. The 750 SUNPIPE: Used in large open areas with room height of approx. 5-7 metres, supermarket for example. The 1000 SUNPIPE: Used in large open areas with room height of approx. 8-9 metres, warehouses for example. Page 18 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com NBS SPECIFICATIONS SUNPIPE® SYSTEMS Monodraught’s SUNPIPE® natural daylight system can be installed on almost any roof type and directs sunlight into a room. The SUNPIPE collects daylight using a patented Diamond dome, then the MIRO-SILVER® finish aluminium tube transfers the light to ceiling level before the ceiling diffuser evenly distributes the light around the room without glare. • FEATURES: »» Glazing details: Clear polycarbonate diamond dome with UV inhibitors, complete with brushed nylon condensation gasket. »» Lining: MIRO-SILVER® finish aluminium tube in 610 mm lengths. »» Ceiling diffuser: Prismatic, with white ceiling trim and 3 mm plywood (we do not supply plywood with the 750 or 1000 systems). • ADVANTAGES: »» Generally no structural alterations required, easily fits between joists and rafters. »» No maintenance required. »» Top domes are self-cleaning due to their shape, eliminating condensation problems. • STANDARDS: »» BS EN ISO 14001 and BS EN ISO 9001. »» The FireGuard ceiling diffuser has been tested to comply with BS 476-20: 1987. »» The Fire Choke collar has been fully tested to current British and European standards (test report TE 39902): • Size: 530, 750, 1000. • Roof Terminal: »» Impact resistant acrylic Diamond shaped dome OR »» UV-protected polycarbonate Diamond shaped dome • Ceiling Diffuser: »» Polycarbonate prismatic diffuser. • Roof Type: »» Bold rolled tile (for 530) »» Felt »» Membrane »» Green roof kit »» Metal »» Pitched slate (for 530) »» Plain Tile (for 530) • Accesories: »» Adjustable elbows (for 530) »» Fire Choke collar (for 530) »» Fireguard diffuser (for 530) »» Fixed elbows (750 0r 1000) »» Integral electric light kit (for 530) »» Motorized light shut-off dampers (530 & 750). »» Security components (for 530) »» Soundguard diffuser (for 530) »» As Standard: • Flashing Type (as standard): »» ABS - For pitched slate roofs – Not applicable for 750/1000 systems. »» ABS with weathering skirt - For pitched plain tiled roofs – Not applicable for 750/1000 systems. »» Code 4 lead - For pitched profiled tiled roofs – Not applicable for 750/1000 systems. »» Galvanised - For Flat Felt / Membrane roofs. »» »» Options: Other bespoke arrangements are available. For sizing guidance or further details, please contact Monodraught Head Office. Approvals: mark : CHAS registered Page 19 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com Square SUNPIPE systems Square SUNPIPE 300, 450 Sizes available: 300, 450 Monodraught’s SUNPIPE® natural daylight system can be installed on almost any roof type and directs sunlight into a room. The SUNPIPE collects daylight using a patented Diamond dome, then the MIRO-SILVER® finish aluminium tube transfers the light to ceiling level before the ceiling diffuser evenly distributes the light around the room without glare. SUNPIPES are suited to almost any application, and have been installed anywhere from residential bedrooms to the Olympic Handball Arena in London. Monodraught’s Square SUNPIPE® natural daylight system is suited to applications where the room being served has a flat ceiling, as opposed to a typical loft conversion with a vaulted ceiling where a normal rooflight can be used. Monodraught’s Square SUNPIPE has been specifically developed to provide an unobtrusive termination tile and slate roofs. The Square SUNPIPE is used in conjunction with Monodarught’s standard 300 and 450 SUNPIPE kits. The square rooflight measures 475 mm x 570 mm and includes an adaptor to allow it to fit the 300 or 450 circular SUNPIPE systems. With the inclusion of an adjustable elbow it is possible to adjust the system to fit any angle of roof pitch. TECHNICAL DETAILS • MATERIAL: »» Rooflight details: Aluminium, sealed double glazed unit with an outer layer of 3 mm clear float glass, a 8 mm air gap and 3 mm clear float inner glass. Comes complete with transition to suit standard 300 and 450 SUNPIPE systems. »» SUNPIPE MIRO-SILVER® finish Aluminium. Suitable for Roof Pitches 15° to 60°. • PERFORMANCE: »» 300: 4685 lumen output in full summer sun (105 Klux). »» 450: 11310 lumen output in full summer sun (105 Klux). • OPTIONS: »» 610 mm (2ft) extension lengths 30°/45° adjustable elbows. »» Motorised light shut off Damper. »» Security Bars. »» Integral Electric Light Kit for night use. »» Fire Collar. »» Fireguard. »» Soundguard. • • 15° min. 60° max. Double glazed unit Standard SUNPIPE DIMENSIONS 300: »» 305 mm Dia SUNPIPE. »» 320 mm Dia ceiling opening required. »» 470 mm x 570 mm roof opening required. Adjustable elbow DIMENSIONS 450: »» 457 mm Dia SUNPIPE. »» 470 mm Dia ceiling opening required. »» 470 mm x 570 mm roof opening required. Page 20 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com Square SUNPIPE 300, 450 GENERAL DESCRIPTION LIGHT OUTPUT PERFORMANCE Data for a typical flat roof application measured 1.5 m below SUNPIPE Diffuser Dia 300 (12”) 450 (18”) Full Summer Sun 105 klux Lux Value Lumen Output of the system 760 4685 1820 1130 Overcast Summer 45 klux Lux Value Lumen Output of the system 330 2040 750 4630 Overcast Winter Lux Value 130 300 Lumen Output of the system 800 1860 Area Lit 14 m² 22 m² PRODUCT OPTIONS 1. 1. Integral Electric Lighting Kit Includes a 50 W extra low voltage Halogen light fitting and transformer to provide light outside of daylight hours. 2. Fire Collar Intumescent ‘Fire Choke’ Fire collars can be integrated within the system to prevent the spread of smoke and fire through the roof to give up to 2 hours protection. 3. 2. 3. Soundguard Soundguard ceiling diffusers can be used in place of the standard polycarbonate diffusers to provide sound attenuation of up to 37dBa. 4. Motorised Shut off Features a butterfly light shut-off damper controlled by a 230V motorised actuator for use in areas such as Lecture Theatres, Conference Halls etc 4. 5. 5. Fireguard Fireguard ceiling diffusers can be used in place of the standard polycarbonate diffusers to provide up to 1 hour fire resistance (only for 530). 6. Double Glazed and Square Ceiling Diffusers are also SUNPIPE options. TYPICAL USES • • The 300 SUNPIPE system is the most popular domestic kit suitable for lighting most average sized rooms. The 450 SUNPIPE system is the largest Square kit and would be suitable for lighting large open spaces. Page 21 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com NBS SPECIFICATIONS 300 or 450 SQUARE SUNPIPE SYSTEM • Rooflight details: Aluminium, sealed double glazed unit with an outer layer of 3 mm clear float glass, a 8 mm air gap and 3 mm clear float inner glass. Internal flashing apron, comes complete with transition to suit standard 300 and 450 SUNPIPE systems and patented Thermoliner®. • Lining: MIRO-SILVER® finish aluminium tube in 610 mm lengths and adjustable elbows to suit installation. • Ceiling Diffuser: Prismatic ceiling diffuser. • Other requirements: All necessary screws, fixings and brackets to install system to be provided by Monodraught. • Accessories: 2 section 30 elbow, 3 section 45 elbow, 610 extension pipe, stainless steel effect ceiling trims, light kit. • Provides light to areas where windows cannot reach. • SUNPIPE systems are guaranteed for ten years against faulty manufacture. Page 22 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com SUNCATCHER® Natural Daylight Systems Page 23 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com ABS SUNCATCHER systems ABS SUNCATCHER 350, 550 Sizes available: 350, 550 The ABS SUNCATCHER® natural daylight and ventilation system combines the principles of the SUNPIPE® natural daylight and WINDCATCHER® natural ventilation systems in one unit. The system has been used extensively in education facilities and commercial offices. The design of the system lends itself particularly well to smaller areas where it would not be economical to fit two separate natural daylight and natural ventilation systems, such as conference and meeting rooms, with each system having a choice of two SUNPIPE options. TECHNICAL DETAILS • MATERIAL: »» Top Dome 4mm UV stabilised polycarbonate or acrylic. »» Terminal ABS construction. »» SUNPIPE MIRO-SILVER® finish Aluminium. • PERFORMANCE 350 (complete with 230 SUNPIPE): »» Provides 16 l/s with an external wind speed of 4 m/s. »» 230 SUNPIPE can light an area up to 7.5 m². • PERFORMANCE 550 (complete with 300 SUNPIPE): »» Class ‘A’ BSRIA tested weathering performance. »» Provides 62 l/s with an external wind speed of 4m/s. »» 300 mm Dia SUNPIPE can light an area up to 14m². • OPTIONS 350 & 550: »» Security Bars. »» Integral Electric Light Kit for night use. »» Fire Collar. • DIMENSIONS 350: »» 430 mm Dia external terminal. »» 320 mm Dia trunk. »» Protrudes approximately 450 mm above a flat roof. »» 230 or 305 mm Dia SUNPIPE system. »» 320 mm Dia roof opening required. »» Ceiling opening varies, dependant on grille type. • UV protected polycarbonate top dome Brushed Nylon condensation trap positioned between dome and collar DIMENSIONS 550: »» 625 mm Dia external terminal. »» 530 mm dia trunk. »» Protrudes approximately 650 mm above a flat roof. »» 300 or 450 mm Dia SUNPIPE system. »» 550 mm Dia roof opening required. »» Ceiling opening varies, dependant on grille type. Page 24 Drop rods and unistrut support frame Trimmers by others, required to support galvanised ceiling transition. Alternativelly transition will be supported by wires Required ceiling opening Ventilating ceiling diffuser arrangement Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com ABS SUNCATCHER 350, 550 GENERAL DESCRIPTION LIGHT OUTPUT PERFORMANCE 350 SUNCATCHER SYSTEM Dia 230 (9”) 300 (12”) Full Summer Sun 105 klux Lux Value Lumen Output of the system 360 2160 760 4460 Overcast Summer 45 klux Lux Value Lumen Output of the system 170 1045 330 1940 Overcast Winter Lux Value 65 130 Lumen Output of the system 670 760 Area Lit 7.5 m² 14 m² 550 SUNCATCHER SYSTEM Dia 300 (12”) 450 (18”) Full Summer Sun 105 klux Lux Value Lumen Output of the system 760 4460 1820 10770 Overcast Summer 45 klux Lux Value Lumen Output of the system 330 1940 750 4410 Overcast Winter Lux Value 130 300 Lumen Output of the system 760 1768 Area Lit 14 m² 22 m² PRODUCT VARIANTS Hemispherical Dome Diffuser NBS SPECIFICATIONS SUNCATCHER® natural ventilation and daylight system The Monodraught SUNCATCHER systems are a method of effectively conveying natural daylight and natural ventilation from roof level down into the building below by combining the principles of the WINDCATCHER® natural ventilation system with Monodraught’s SUNPIPE® natural daylight system. Page 25 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com The SUNCATCHER system is divided internally into four quadrants so that whichever direction the wind is blowing one or more quadrants is facing into the wind. The windward quadrants supply air under the action of positive wind pressure, and the leeward quadrants extract stale air under the action of negative wind pressure. On still days, the SUNCATCHER system acts as a conventional passive stack system using the natural buoyancy of warm internal air to stimulate air flow out of the building. The SUNPIPE collects daylight using a patented Diamond dome, then the silverised mirror-finished aluminium tube transfers light to the room, and finally the ceiling diffuser evenly distributes the light around the room without glare. • FEATURES: »» Type: ABS 350, ABS 550. »» Shape: Circular. »» Controls: Manual. »» Outer Casing: ABS. »» Ceiling grille: White hit/missed grille or white powder coated eggcrate. • ADVANTAGES: »» Cost effective: No running costs or energy consumption. »» Healthier system: Brings a steady supply of fresh air into the building, whilst at the same time expelling stale air to the atmosphere. »» Is sustainable energy in action: Does not use any fossil fuelled energy but relies on harnessing wind power and the thermal rise of warm air. »» Night time cooling. »» SUNPIPE top domes are self-cleaning due to their shape. »» Evenly diffused natural daylight provided to internal spaces. • STANDARDS: »» Complies with Building Regulations (E&W) Approved Document F in providing a Passive Stack Ventilation (PSV) system in accordance with BRE Paper, Reference 13/94. Manufactured in compliance with BS EN ISO 14001 and BS EN ISO 9001. »» Internal Airways: Airway protected internally with mesh. »» Colour: • ABS - Dark Grey (RAL 7010). »» Options: Bespoke systems are also available. For sizing guidance or further details, please contact Monodraught Head Office. »» Approvals: : CHAS registered Page 26 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com SOLA-VENT® Natural Daylight Systems Page 27 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com SOLA-VENT systems SOLA-VENT 230, 300 Sizes available: 230, 300. The SOLA-VENT® solar powered daylight and extract system is a fully integrated bathroom light and ventilation kit, incorporating the SUNPIPE® natural daylight system, two compact halogen downlighters and a solar powered extract fan all in one unit. The system is ideal for bathrooms and shower rooms where ventilation is essential. 230 SOLA-VENT System: This system incorporates a 230 SUNPIPE, a solar powered extract fan and two compact‑flourescent downlighters. The system is ideally suited to internal bathrooms and shower rooms to meet current Building Regulations to provide 15 l/s extract ventilation. 300 SOLA-VENT System: This is designed for larger areas, such as kitchens and utility areas, utilising the 300 SUNPIPE, which provides approximately twice as much natural light as the smaller 230 SOLA-VENT system. It also incorporates a higher rated fan. When these systems are used on commercial applications, such as Schools or Office areas, the overall performance of the SOLA-VENT system actually increases. Both systems also have an option for a mains powered back-up facility whereby if the system is intended for use for long hours than designed for, the mains supply can charge the battery pack should the batteries fall below the threshold voltage provided by the solar panel. TECHNICAL DETAILS • MATERIAL: »» Top Dome 4mm UV stabilised polycarbonate or acrylic. »» Flashing ABS construction with integral vent outlet. »» SUNPIPE Super Silver mirror finish Aluminium. • PERFORMANCE 230: »» Provides 15 l/s extract. »» 230 mm Dia SUNPIPE can light an area up to 7.5 m². »» 15 W Polycrystalline silicon Photovoltaic panel charges AGM battery. • PERFORMANCE 300: »» Provides 30 l/s extract. »» 305 mm Dia SUNPIPE can light an area up to 14 m². »» 40 W Polycrystalline silicon Photovoltaic panel charges AGM battery. • OPTIONS: »» Sirroco ceiling diffuser. Page 28 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com SOLA-VENT 230, 300 GENERAL DESCRIPTION • DIMENSIONS 230: »» 680 x 735 mm flashing plate. »» 580 x 350 mm ceiling opening required. »» 230 mm Dia SUNPIPE system. »» Ventilating ceiling diffuser arrangement. • DIMENSIONS 300: »» 890 x 935 mm flashing plate »» 660 x 460 mm ceiling opening required »» 300 mm Dia SUNPIPE system »» Ventilating ceiling diffuser arrangement LIGHT OUTPUT PERFORMANCE 350 SUNCATCHER SYSTEM Dia 230 (9”) 300 (12”) Full Summer Sun 105 klux Lux Value Lumen Output of the system 360 2160 760 4460 Overcast Summer 45 klux Lux Value Lumen Output of the system 170 1045 330 1940 Overcast Winter Lux Value 65 130 Lumen Output of the system 670 760 Area Lit 7.5 m² 14 m² PRODUCT VARIANTS Sirroco Ceiling Diffuser Vents Light Light PIR Diffuser Dome Page 29 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com WIRING DETAILS Control Box Battery 2.1 mm barnell jack Solar Panel 3-way connector 2-way connector 4-way connector Mains Switching Adaptor Fan PIR Sensor Page 30 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com WINDCATCHER X-AIR® Natural Ventilation Systems Page 31 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com X-AIR systems WINDCATCHER X-AIR Sizes available: 110, 140, 170, 200. The WINDCATCHER X-AIR is a the next generation of natural ventilation system featuring Monodraught patented ACTIVLOUVRE® modulating aerofoil louvre technology. The system consists of an external static louvre and internal active louvre arrangement, which varies the opening and free area through the louvre face. The variable louvres can provide maximum ventilation rates when fully open or modulated to vary weather resistance or closed to prevent the ingress of precipitation allowing Monodraught to have our unic no leak guarantee. In addition to the ACTIVLOUVRE arrangement, the system also incorporates external air catchment fins to provide greater area at the louvre improving performance in relation to wind speed. Pressure release vanes at the fins provide a means to reduce face pressure under high winds. The systems can also be specified to include solar powered architectural lighting. TECHNICAL DETAILS • MATERIAL: »» Injection Moulded ASA. »» Extruded ABS. »» 6063 Aluminium extrusion. »» 10W Monocrystalline photovoltaic solar panel (LED version only). • OPTIONS: »» Colours (RAL 7037 Dusty Grey / RAL 7038 Agate Grey). »» Architectural LED lighting (white / blue /green). »» Acoustic foam (25 mm, 50 mm). »» GRP extended colour-matched skirt (to suit roof pitch from 15 – 35 degrees). • • GUARANTEE: »» 10 year limited warranty. PERFORMANCE 110: • DIMENSIONS 110: »» Fire - DIN EN 13501-1: 2010-01 (Class E). »» 850 mm (w) x 850 mm (d). »» Sound - BS EN 20140-10:1992. »» 980 mm (h) – (Standard). »» Sound - ISO 140-10:1991. »» 1020 mm (h) – (LED Architectural version). »» Power supply range; 19.2 – 28.8 V DC. 0 – 10 V. »» 50 mm high louvre opening. »» Power consumption; 2 W @ nominal force, 0.4 W at »» 90 mm louvre pitch. rest. »» 6 louvre openings. »» Actuating force; 450 N @ nominal voltage. Running »» 0.244 m² free area per face. time; 150 s / 100 mm. »» Actuating force; 10 Nm @ nominal voltage. Running time; 150 s / 95° (for volume control damper). • WEIGHT 110: »» IP54 rated actuator motors »» 55 kg Net (excluding packaging). Page 32 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com WINDCATCHER X-AIR GENERAL DESCRIPTION • PERFORMANCE 140: • DIMENSIONS 140: »» Fire - DIN EN 13501-1: 2010-01 (Class E). »» 1047 mm (w) x 1047 mm (d). »» Sound - BS EN 20140-10:1992. »» 1158 mm (h) – (Standard). »» Sound - ISO 140-10:1991. »» 1199 mm (h) – (LED Architectural version). »» Power supply range; 19.2 – 28.8 V DC. 0 – 10 V. »» 50 mm high louvre opening. »» Power consumption; 2 W @ nominal force, 0.4 W at »» 90 mm louvre pitch. rest. »» 8 louvre openings. »» Actuating force; 450 N @ nominal voltage. Running »» 0.421 m² free area per face. time; 150 s / 100 mm. »» Actuating force; 10 Nm @ nominal voltage. Running time; 150 s / 95° (for volume control damper). • WEIGHT 140: »» IP54 rated actuator motors. »» 70 kg Net (excluding packaging). • PERFORMANCE 170: • DIMENSIONS 170: »» Fire - DIN EN 13501-1: 2010-01 (Class E). »» 1247 mm (w) x 1247 mm (d). »» Sound - BS EN 20140-10:1992. »» 1337 mm (h) – (Standard). »» Sound - ISO 140-10:1991. »» 1379 mm (h) – (LED Architectural version). »» Power supply range; 19.2 – 28.8 V DC. 0 – 10 V. »» 50 mm high louvre opening. »» Power consumption; 2 W @ nominal force, 0.4 W at »» 90 mm louvre pitch. rest. »» 10 louvre openings. »» Actuating force; 450 N @ nominal voltage. Running »» 0.646 m² free area per face. time; 150 s / 100 mm. »» Actuating force; 10 Nm @ nominal voltage. Running time; 150 s / 95° (for volume control damper). • WEIGHT 170: »» IP54 rated actuator motors. »» 95 kg Net (excluding packaging). • PERFORMANCE 200: • DIMENSIONS 200: »» Fire - DIN EN 13501-1: 2010-01 (Class E). »» 1247 mm (w) x 1247 mm (d). »» Sound - BS EN 20140-10:1992. »» 1337 mm (h) – (Standard). »» Sound - ISO 140-10:1991. »» 1379 mm (h) – (LED Architectural version). »» Power supply range; 19.2 – 28.8V DC. 0 – 10V. »» 50 mm high louvre opening. »» Power consumption; 2 W @ nominal force, 0.4 W at »» 90 mm louvre pitch. rest. »» 12 louvre openings. »» Actuating force; 450 N @ nominal voltage. Running »» 0.920 m² free area per face. time; 150 s / 100 mm. »» Actuating force; 10Nm @ nominal voltage. Running time; 150 s / 95° (for volume control damper). • WEIGHT 200: »» IP54 rated actuator motors. »» 120 kg Net (excluding packaging). Page 33 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com WIRING DETAILS • Cable Specification: »» Farnell: 1190288. »» RS: 660-4099. »» Electrical Wholesaler Reference: 16-2-6A. »» Number of Cores: 6. »» CSA: 0.5 mm². »» »» »» »» »» »» Screened: No. Voltage Rating: 440Vac. Current Rating: 2.5A. Core Strands: 16/0.2 mm. Outside Dia: 7.7 mm. Insulation Material: PVC. Wiring for Master connection box out to slave units in the same control zone should use 4 core cable (16-2-4A. RS: 660-4096 or Farnell 1190286), and only the Blue, Green, Yellow and Red cables are connected to the subsequent slave systems. (The feedback lines MUST NOT be commoned between systems). PRODUCT VARIANTS Standard • 1015 • X-AIR 110 - LED 974 846 • X-AIR 110 – Standard LED Architectural Lighting 846 • 846 846 Page 34 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com 1046 1195 1046 • X-AIR 140 - LED 1154 1046 • X-AIR 140 – Standard 1046 1375 1247 • X-AIR 170 - LED 1333 1247 • X-AIR 170 – Standard 1247 1247 1568 1447 • X-AIR 200 - LED 1528 1447 • X-AIR 200 – Standard 1447 1447 Page 35 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com ACOUSTIC PERFORMANCE * Designates measurement corrected for background. ## Designates limit of measurement due to background. %% Designates limit of measurement due to background. $$ Designates limit of measurement due to flanking. ++ Designates frequency beyond standard. X-AIR 140 (CLOSED) X-AIR 140 (OPEN) Frequency (Hz) X-AIR 140 (CLOSED) 25 mm Acoustic Foam X-AIR 140 (OPEN) 25 mm Acoustic Foam X-AIR 140 (CLOSED) 50 mm Acoustic Foam X-AIR 140 (OPEN) 50 mm Acoustic Foam Element normalised level difference Dn,e dB 1/3 Oct 1/1 Oct 1/3 Oct 1/1 Oct 1/3 Oct 1/1 Oct 1/3 Oct 1/1 Oct 1/3 Oct 1/1Oct 1/3 Oct 1/1 Oct 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 + 8000 + 1000 + Average 100-3150 Dn,e,w (C;Ctr) = 30.8 $ 29.6 31.1 34.0 % 34.2 31.4 33.00 34.0 35.3 36.8 36.5 37.6 37.8 38.1 38.0 38.2 37.2 38.6 38.7 41.1 45.1 44.4 44.6 44.2 41.7 40.5 41.4 42.4 12.8 14.7 17.8 18.5 15.5 17.3 16.6 18.8 18.8 18.1 18.3 17.3 17.4 17.8 18.3 19.1 19.6 19.8 20.5 19.4 20.2 14.7 61.9 17.9 17.9 17.8 19.5 20.0 25.7 % 25.8 32.0 30.6 29.1 32.5 33.4 35.2 36.9 37.2 39.9 42.6 43.1 46.0 49.1 53.9 52.1 53.6 49.8 47.3 48.1 % 27.0 30.5 34.9 34.9 45.4 53.1 48.3 11.4 15.1 18.1 19.8 16.8 19.1 20.2 22.3 23.5 23.6 26.2 26.3 25.6 27.3 28.5 28.7 29.4 31.3 30.5 28.7 29.4 14.0 18.4 21.8 25.2 26.9 29.7 29.5 31.1 $ 31.5 % 37.6 % 35.3 34.8 38.9 40.8 41.1 42.6 44.1 46.1 49.1 49.8 52.2 54.5 59.3 57.7 58.0 54.0 52.1 52.8 $ 32.5 36.0 41.4 46.0 51.8 58.3 52.9 12.8 16.5 21.4 22.3 20.0 22.6 23.3 24.6 26.5 26.8 28.5 29.2 29.5 30.4 30.7 32.7 33.0 33.9 34.5 32.5 32.9 15.7 21.5 24.6 28.1 30.2 33.2 33.2 36.2 17.3 37.1 22.0 43.1 24.9 38 (0;-1) dB 18 (0;0) dB 39 (0;-3) dB 25 (0;-3) dB 46 (-1;-4) dB 28 (-1;-3) dB Rating according to BS EN ISO 717-1:1997. Page 36 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com * Designates measurement corrected for background. ## Designates limit of measurement due to background. %% Designates limit of measurement due to background. $$ Designates limit of measurement due to flanking. ++ Designates frequency beyond standard. X-AIR 170 (CLOSED) X-AIR 170 (OPEN) Frequency (Hz) X-AIR 170 (CLOSED) 25 mm Acoustic Foam X-AIR 170 (OPEN) 25 mm Acoustic Foam X-AIR 170 (CLOSED) 50 mm Acoustic Foam X-AIR 170 (OPEN) 50 mm Acoustic Foam Element normalised level difference Dn,e dB 1/3 Oct 1/1 Oct 1/3 Oct 1/1 Oct 1/3 Oct 1/1 Oct 1/3 Oct 1/1 Oct 1/3 Oct 1/1Oct 1/3 Oct 1/1 Oct 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 + 8000 + 1000 + Average 100-3150 Dn,e,w (C;Ctr) = 26.0 % 25.8 30.4 % 25.4 26.3 29.8 31.9 31.2 33.0 32.4 33.2 34.1 34.5 36.3 39.5 42.6 39.9 39.3 38.4 37.4 39.8 26.9 26.8 39.9 33.2 36.3 40.4 38.4 9.8 11.2 16.3 13.9 12.7 15.2 15.0 14.3 14.6 15.0 15.0 14.1 14.0 15.5 16.1 16.6 16.6 16.9 17.5 16.3 16.7 11.7 13.8 14.6 14.7 15.1 16.7 16.8 21.4 23.3 28.3 23.2 24.9 27.6 30.3 31.1 34.2 35.7 37.1 38.7 40.2 43.4 47.6 51.8 48.6 48.0 45.3 43.3 44.7 23.5 24.9 31.6 37.0 42.8 49.2 44.3 9.4 12.9 18.8 14.3 13.8 16.6 27.5 17.4 20.6 20.9 22.6 22.6 23.0 24.3 25.3 26.5 26.9 28.4 28.4 26.0 26.7 12.3 14.7 18.3 22.0 24.1 27.2 26.9 21.6 24.8 27.9 24.1 26.9 28.9 31.5 32.2 34.9 36.1 37.4 39.1 40.4 43.4 47.1 52.0 49.8 49.2 46.2 44.5 46.8 % 24.0 26.2 32.6 37.3 42.8 50.2 45.7 9.6 14.1 20.7 15.9 16.5 19.2 19.1 19.0 21.7 21.9 23.3 23.7 23.6 25.1 26.1 27.1 28.3 29.7 29.0 27.1 28.8 12.8 17.0 19.8 22.9 24.8 28.2 28.2 32.0 14.3 33.7 19.2 34.7 20.4 34 (0;-2) dB 15 (0;0) dB 36 (-1;-4) dB 22 (-1;-3) dB 37 (-1;-4) dB 23 (0;-2) dB Rating according to BS EN ISO 717-1:1997. Page 37 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com * Designates measurement corrected for background. ## Designates limit of measurement due to background. %% Designates limit of measurement due to background. $$ Designates limit of measurement due to flanking. ++ Designates frequency beyond standard. X-AIR 200 (CLOSED) X-AIR 200 (OPEN) Frequency (Hz) X-AIR 200 (CLOSED) 25 mm Acoustic Foam X-AIR 200 (OPEN) 25 mm Acoustic Foam X-AIR 200 (CLOSED) 50 mm Acoustic Foam X-AIR 200 (OPEN) 50 mm Acoustic Foam Element normalised level difference Dn,e dB 1/3 Oct 1/1 Oct 1/3 Oct 1/1 Oct 1/3 Oct 1/1 Oct 1/3 Oct 1/1 Oct 1/3 Oct 1/1Oct 1/3 Oct 1/1 Oct 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 + 8000 + 1000 + Average 100-3150 Dn,e,w (C;Ctr) = 19.2 22.5 23.1 22.7 24.5 24.6 26.7 27.1 27.5 27.7 27.3 28.9 29.2 31.1 34.4 37.9 36.1 35.0 37.0 36.1 37.3 21.2 23.9 27.1 27.9 31.1 36.2 36.8 8.9 11.2 14.6 13.0 12.8 13.8 13.9 13.6 13.3 13.9 13.3 13.0 13.2 14.9 15.3 15.6 16.2 16.7 17.5 16.1 17.8 11.0 13.1 13.3 13.4 14.4 16.1 17.1 22.1 26.1 25.3 24.8 28.2 29.3 30.9 32.8 34.2 35.3 36.3 38.3 39.7 42.7 46.9 51.5 49.5 48.2 49.0 48.6 49.9 % 24.2 27.0 32.4 36.5 42.2 49.5 49.2 9.5 13.1 14.5 13.6 14.2 15.7 16.3 17.3 18.3 19.2 20.5 20.7 21.1 22.7 23.7 24.5 25.4 26.8 26.9 25.4 26.3 11.8 14.4 17.2 20.1 22.4 25.5 26.1 24.2 28.7 26.6 29.4 30.9 31.7 33.9 35.7 36.6 37.0 38.3 40.6 42.7 45.0 48.6 53.2 51.5 50.4 50.9 50.1 51.0 $ 26.1 30.5 35.3 38.4 44.8 51.5 50.6 9.5 15.1 15.7 16.0 17.3 17.9 18.6 19.9 20.0 20.5 21.3 22.0 21.6 23.7 24.8 26.1 26.5 27.8 27.8 25.8 26.4 12.5 17.0 19.5 21.2 23.2 26.8 26.6 27.2 13.4 34.0 17.8 36.4 19.4 29 dB 14 dB 36 dB 21 dB 39 dB 22 dB Rating according to BS EN ISO 717-1:1997. Page 38 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com X-AIR systems SOLA-BOOST X-AIR Sizes available: 140, 170, 200. The SOLA-BOOST X-AIR is the next generation of natural ventilation system featuring the patented ACTIVLOUVRE® modulating aerofoil louvre technology and DC solar powered fan controlled by Monodraught’s PowerTrack™ system. The system consists of an external static louvre and internal active louvre arrangement, which varies the opening and free area through the louvre face. The variable louvres can provide maximum ventilation rates when fully open or modulated to vary the weather resistance or closed to prevent the ingress of precipitation. A fan served by a central core provides intake or extract air (intake as standard), powered by solar panels situated at within the system capping. The fan is designed to provide the additional ventilation when it is need most, during summer, but with zero running cost. In order to maximise the performance of the solar powered fan, the system utilises the PowerTrack™ control system, which maximises the solar output to provide a smooth current from the solar panels and optimised fan flow. In addition to the ACTIVLOUVRE arrangement, the system also incorporates external air catchment fins to provide greater area at the louvre improving performance in relation to wind speed. Pressure release vanes at the fins provide a means to reduce face pressure under high winds. The systems can also be specified to include solar powered architectural lighting. TECHNICAL DETAILS • MATERIAL: »» Injection Moulded ASA. »» Extruded Luran ABS. »» 6063 Aluminium extrusion. »» 10W Monocrystalline photovoltaic solar module. »» 4 x 15W Monocrystalline photovoltaic solar modules. • OPTIONS: »» Colours (RAL 7037 Dusty Grey / RAL 7038 Agate Grey). »» Architectural LED lighting (white / blue /green). »» Acoustic foam (25 mm, 50 mm). »» GRP extended colour-matched skirt (to suit roof pitch from 15 – 35 degrees). • GUARANTEE: »» 10 year limited warranty. Page 39 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com SOLA-BOOST X-AIR GENERAL DESCRIPTION • PERFORMANCE 140: • DIMENSIONS 140: »» Fire - DIN EN 13501-1: 2010-01 (Class E). »» 1047mm (w) x 1047mm (d). »» Sound - BS EN 20140-10:1992. »» 1405 mm (h). »» Sound - ISO 140-10:1991. »» 50 mm high louvre opening. »» Power supply range; 19.2 – 28.8 V DC. 0 – 10 V. »» 90 mm louvre pitch. »» Power consumption; 2 W @ nominal force, 0.4 W at »» 12 louvre openings. rest. »» 0.421 m² free area per face (Natural Ventilation). »» Actuating force; 450 N @ nominal voltage. Running »» 0.105 m² free area per face (Fan opening). time; 150 s / 100 mm. »» Actuating force; 10 Nm @ nominal voltage. »» Running time; 150 s / 95° (for volume control damper). • WEIGHT 140: »» P54 rated actuator motors. »» 85 kg Net (excluding packaging). »» 260 l/s maximum fan flow. • PERFORMANCE 170: • DIMENSIONS 170: »» Fire - DIN EN 13501-1: 2010-01 (Class E). »» 1247mm (w) x 1247mm (d). »» Sound - BS EN 20140-10:1992. »» 1585 mm (h). »» Sound - ISO 140-10:1991. »» 50 mm high louvre opening. »» Power supply range; 19.2 – 28.8 V DC. 0 – 10 V. »» 90 mm louvre pitch. »» Power consumption; 2 W @ nominal force, 0.4 W at »» 12 louvre openings. rest. »» 0.646 m² free area per face (Natural Ventilation). »» Actuating force; 450 N @ nominal voltage. Running »» 0.129 m² free area per face (Fan opening). time; 150 s / 100 mm. »» Actuating force; 10 Nm @ nominal voltage. Running time; 150 s / 95° (for volume control damper). • WEIGHT 170: »» IP54 rated actuator motors. »» 112 kg Net (excluding packaging). »» 260 l/s maximum fan flow. • PERFORMANCE 200: • DIMENSIONS 200: »» Fire - DIN EN 13501-1: 2010-01 (Class E). »» 1247mm (w) x 1247mm (d). »» Sound - BS EN 20140-10:1992. »» 1780 mm (h). »» Sound - ISO 140-10:1991. »» 50 mm high louvre opening. »» Power supply range; 19.2 – 28.8 V DC. 0 – 10 V. »» 90 mm louvre pitch. »» Power consumption; 2 W @ nominal force, 0.4 W at »» 14 louvre openings. rest. »» 0.920 m² free area per face (Natural Ventilation). »» Actuating force; 450 N @ nominal voltage. Running »» 0.153 m² free area per face (Fan opening). time; 150 s / 100 mm. »» Actuating force; 10 Nm @ nominal voltage. Running time; 150 s / 95° (for volume control damper). • WEIGHT 200: »» IP54 rated actuator motors. »» 137 kg Net (excluding packaging). »» 260 l/s maximum fan flow. Page 40 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com WIRING DETAILS • Cable Specification: »» Farnell: 1190286. »» RS: 660-4096. »» Electrical Wholesaler Reference: 16-2-6A. »» Number of Cores: 4. »» CSA: 0.5 mm². »» »» »» »» »» »» Screened: No. Voltage Rating: 440Vac. Current Rating: 2.5A. Core Strands: 16/0.2 mm. Outside Dia: 6.7 mm. Insulation Material: PVC. Monodraught provides a 10m long Cat 5E network cable, as standard, for connecting to wall mounted controller. Should additional length be required, these must be straight wired to TIA/EIA-568-B RJ45 wiring standard (T-568B at both ends]. PRODUCT VARIANTS 1401 1046 • X-AIR 140 – Standard 1046 1246 1778 1445 • X-AIR 200 – Standard 1581 1246 • X-AIR 170 – Standard 1445 Page 41 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com VENTSAIR Natural Ventilation Systems Page 42 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com VENTSAIR systems VENTSAIR Roof Mounted Terminals The VENTSAIR Roof Mounted Terminals have a similar appearance to the standard WINDCATCHER systems but have a different internal configuration to allow for dedicated intake or exhaust requirements. The systems are often used in conjunction with other ventilation items to employ a cross ventilation strategy. TECHNICAL DETAILS • MATERIAL: »» Roof terminal GRP construction in class 1 fire retardant resin with GRP airways. »» Outer Casing: Glass-fibre construction in Class 1 fire retardant resin. »» Internal Airways: GRP airway protected internally with Trilayer Weather Protection. • OPTIONS: »» GRP construction. • PERFORMANCE: »» Class ‘A’ BSRIA tested weathering performance. »» Anti-Bird Mesh. »» Trilayer Weather Protection. • DIMENSIONS: »» GRP systems manufactured to any bespoke arrangement. • GUARENTEE: »» 10 year limited warranty. Stale air out Trilayer Weather Protection Weatherproof louvres Motorised volume control dampers Ceiling Diffuser Page 43 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com VENTSAIR Roof Mounted Terminals GENERAL DESCRIPTION NBS SPECIFICATIONS VENTSAIR ROOF MOUNTED SYSTEMS • GENERAL: »» Manufacturer: Monodraught Ltd, Halifax House, Cressex Business Park, High Wycombe, Bucks HP12 3SE, Tel: 01494 897700, Fax: 01494 532465. »» Type: Monodraught VENTSAIR roof mounted passive ventilation system. »» Outer Casing: Glass-fibre construction in Class 1 fire retardant resin. »» Internal Airways: GRP airway protected internally with plastic anti-bird mesh. »» Capping: GRP construction. »» Kerb: Roofers prepared kerb upstand to suit associated roof. »» Volume Control Dampers with 24Volt actuator. »» Ceiling Grilles: White powder coated eggcrate or linear bar grilles. »» Controls: Automatic control: iNVent programmable control system with night-time cooling facility, temperature sensors and manual override – Contractor to allow for internal electrical wiring. • EXECUTION: MONODRAUGHT VENTILATION SYSTEMS »» Installation: Install in accordance with the manufacturer’s recommendations. »» Access above 3 m and hoisting to be provided by Main Contractor. • COMPLETITION: COMMISSIONING »» Monodraught ventilation system: Submit records to demonstrate that commissioning of the system has taken place. Confirm that the system has been set up and is working within the parameters recommended by the system manufacturer. »» Operation: Examine system. Test the operation of equipment, controls and sensors. Verify correct operation. Submit report. »» Wiring: Electrical and Control wiring to be carried out by an electrical contractor. • OPERATION AND MAINTENANCE: »» Operating and maintenance instructions: Submit copies of manufacturers’ operating and maintenance instructions for equipment and controls. »» Monodraught VENTSAIR roof mounted systems are covered by a 10 year guarantee. »» Dampers and Controls fitted with Monodraught systems will be covered by standard manufacturer’s warranty. Page 44 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com WINDCATCHER® Natural Ventilation Systems Page 45 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com WINDCATCHER systems WINDCATCHER CLASSIC (Square) Sizes available: 95, 125, 155, 185, 225. The WINDCATCHER CLASSIC is an energy free natural ventilation system encompassing the benefits of both top-down and passive stack ventilation. The system consists of an external louvre protected internally by a Trilayer Weather Protection and internally divided. The simple, but effective design of the system provides fresh air during the daytime as well as night-time cooling. When coupled with Monodraught’s iNVent control system (or similar BMS), and operated under Monodraught proven strategy, the system is capable of providing temperature and CO2 demand controlled ventilation, by means of energy efficient motorised volume control dampers. Due to the flexibility of the WINDCATCHER CLASSIC, the system can be tailored to suit the needs of almost any area. The systems technological ability has been proven within schools, colleges, healthcare environments, commercial properties as well as many other areas. TECHNICAL DETAILS • MATERIAL: »» GRP Glass fibre reinforced. »» Colour match gel coat finish. »» Trilayer Weather Protection. • OPTIONS: »» Colours; Available in any RAL or BS 4800 colour (Excludes RAL & BS metallic finishes). »» Truncated Capping (to suit specified pitch). »» Modified & extended skirt arrangements (to suit specified roof pitch and alternate upstand arrangements, on request). »» Acoustic foam (25 mm, 50 mm). • GUARANTEE: »» 10 year limited warranty. • PERFORMANCE: »» Fire – BS 476-3:2004 / BS 476-24:1987. »» Sound - BS EN 20140-10:1992. »» Power supply range; 19.2 – 28.8 V DC. 0 – 10 V. »» Power consumption; 2W @ nominal force, 0.4 W at rest, 4 VA (wire sizing). »» Actuating force; 10 Nm @ nominal voltage. Running time; 150 s / 95° (for volume control damper). »» IP54 rated actuator motor. • Page 46 DIMENSIONS: »» Dim A: Capping Width. »» Dim B: Capping Height. »» Dim C: Louvre Height. »» Dim D: Skirt Height. »» Dim E: Trunk Length. »» Dim F: Trunk Width. »» 40 mm high louvre opening. »» 70 mm louvre pitch. Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com WINDCATCHER CLASSIC (Square) GENERAL DESCRIPTION WINDCATCHER Classic Systems (Square) - Dimensions System Size Capping Width Dim A 95 706 125 906 155 1106 185 1206 225 1506 Capping Height Dim B 245 271 298 325 363 Louvre Skirt Trunk Trunk Weight Height Height Length Width Dim C Dim D# Dim E# Dim F kg 460 150 278 600 49 600 150 278 800 74 740 150 278 1000 155 880 150 278 1200 157 1090 150 278 1500 214 No. of Louvres 7 9 11 13 16 Louvre free area / face m2 0.196 0.324 0.484 0.531 0.804 ## Dimension may change subject to roof construction, pitch, roof thickness, installaion method and upstand requirements. All dimension shown in mm. WIRING DETAILS • Cable Specification: »» Farnell: 1190282. »» RS: 660-4087. »» Electrical Wholesaler Reference: 16-2-3A. »» Number of Cores: 3. »» CSA: 0.5 mm². »» »» »» »» »» »» Screened: No. Voltage Rating: 440Vac. Current Rating: 2.5A. Core Strands: 16/0.2 mm. Outside Dia: 6.2 mm. Insulation Material: PVC. Page 47 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com PRODUCT VARIANTS Truncated Capping A • WINDCATCHER CLASSIC – Truncated Capping B A F C • WINDCATCHER CLASSIC – Standard Capping • D Standard Capping E • Page 48 F Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com WINDCATCHER systems WINDCATCHER CLASSIC (Circular) Sizes available: 95, 125, 155, 185, 225. The WINDCATCHER CLASSIC is an energy free natural ventilation system encompassing the benefits of both top-down and passive stack ventilation. The system consists of an external louvre protected internally by a Trilayer Weather Protection and internally divided. The simple, but effective design of the system provides fresh air during the daytime as well as night-time cooling. When coupled with Monodraught’s iNVent control system (or similar BMS), and operated under Monodraught proven strategy, the system is capable of providing temperature and CO2 demand controlled ventilation, by means of energy efficient motorised volume control dampers. Due to the flexibility of the WINDCATCHER CLASSIC, the system can be tailored to suit the needs of almost any area. The systems technological ability has been proven within schools, colleges, healthcare environments, commercial properties as well as many other areas. TECHNICAL DETAILS • MATERIAL: »» GRP Glass fibre reinforced. »» Colour match gel coat finish. »» Trilayer Weather Protection. • OPTIONS: »» Colours; Available in any RAL or BS 4800 colour (Excludes RAL & BS metallic finishes). »» Truncated Capping (to suit specified pitch). »» Modified & extended skirt arrangements (to suit specified roof pitch and alternate upstand arrangements, on request). »» Acoustic foam (25 mm, 50 mm). • PERFORMANCE: »» Fire – BS 476-3:2004 / BS 476-24:1987. »» Sound - BS EN 20140-10:1992. »» Power supply range; 19.2 – 28.8 V DC. 0 – 10 V. »» Power consumption; 2W @ nominal force, 0.4 W at rest, 4 VA (wire sizing). »» Actuating force; 10 Nm (for systems up to 155) & 20 Nm (for systems 155 and larger) @ nominal voltage. Running time; 150 s / 95° (for volume control damper). »» IP54 rated actuator motor. • Page 49 • GUARANTEE: »» 10 year limited warranty. DIMENSIONS: »» Dim A: Capping Width. »» Dim B: Capping Height. »» Dim C: Louvre Height. »» Dim D: Skirt Height. »» Dim E: Trunk Length. »» Dim F: Trunk Width. »» 40 mm high louvre opening. »» 70 mm louvre pitch. Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com WINDCATCHER CLASSIC (Circular) GENERAL DESCRIPTION PRODUCT VARIANTS WINDCATCHER Classic Systems (Circular) - Dimensions System Size Capping Capping Louvre Skirt Trunk Trunk Weight No. of Width Height Height Height Length Width Louvres Dim A Ø Dim B Dim C Dim D# Dim E# Dim F Ø Dim G Ø kg 95 900 203 460 150 278 600 800 52 7 125 1100 223 600 150 278 800 1000 78 9 155 1300 238 740 150 278 1000 1200 118 11 185 1500 250 880 150 278 1200 1400 156 13 225 1800 263 1090 150 278 1500 1700 214 16 Louvre free area / face m2 0.154 0.255 0.484 0.380 0.804 ## Dimension may change subject to roof construction, pitch, roof thickness, installaion method and upstand requirements. All dimension shown in mm. WIRING DETAILS • Cable Specification: »» Farnell: 1190282. »» RS: 660-4087. »» Electrical Wholesaler Reference: 16-2-3A. »» Number of Cores: 3. »» CSA: 0.5 mm². • »» »» »» »» »» »» Screened: No. Voltage Rating: 440Vac. Current Rating: 2.5A. Core Strands: 16/0.2 mm. Outside Dia: 6.2 mm. Insulation Material: PVC. • WINDCATCHER CLASSIC 95 – Circular Windcatcher Circular Page 50 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com WINDCATCHER systems WINDCATCHER CLASSIC RCT (Rectangular) The WINDCATCHER CLASSIC is an energy free natural ventilation system encompassing the benefits of both top-down and passive stack ventilation. The system consists of an external louvre protected internally by a Trilayer Weather Protection and internally divided. The simple, but effective design of the system provides fresh air during the daytime as well as night-time cooling. When coupled with Monodraught’s iNVent control system (or similar BMS), and operated under Monodraught proven strategy, the system is capable of providing temperature and CO2 demand controlled ventilation, by means of energy efficient motorised volume control dampers. Due to the flexibility of the WINDCATCHER CLASSIC, the system can be tailored to suit the needs of almost any area. The systems technological ability has been proven within schools, colleges, healthcare environments, commercial properties as well as many other areas. TECHNICAL DETAILS • MATERIAL: »» GRP Glass fibre reinforced. »» Colour match gel coat finish. »» Trilayer Weather Protection. • OPTIONS: »» Colours; Available in any RAL or BS 4800 colour (Excludes RAL & BS metallic finishes). »» Truncated Capping (to suit specified pitch). »» Modified & extended skirt arrangements (to suit specified roof pitch and alternate upstand arrangements, on request). »» Acoustic foam (25 mm, 50 mm). • GUARANTEE: »» 10 year limited warranty. WIRING DETAILS • Cable Specification: »» »» Farnell: 1190282. »» »» RS: 660-4087. »» Electrical Wholesaler »» »» Reference: 16-2-3A. »» Number of Cores: 3. »» »» »» CSA: 0.5 mm². Screened: No. Voltage Rating: 440Vac. Current Rating: 2.5A. Core Strands: 16/0.2 mm. Outside Dia: 6.2 mm. Insulation Material: PVC. Page 51 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com WINDCATCHER CLASSIC (Rectangular) GENERAL DESCRIPTION WINDCATCHER systems WINDCATCHER CLASSIC OVL (Oval) The WINDCATCHER CLASSIC is an energy free natural ventilation system encompassing the benefits of both top-down and passive stack ventilation. The system consists of an external louvre protected internally by a Trilayer Weather Protection and internally divided. The simple, but effective design of the system provides fresh air during the daytime as well as night-time cooling. When coupled with Monodraught’s iNVent control system (or similar BMS), and operated under Monodraught proven strategy, the system is capable of providing temperature and CO2 demand controlled ventilation, by means of energy efficient motorised volume control dampers. Due to the flexibility of the WINDCATCHER CLASSIC, the system can be tailored to suit the needs of almost any area. The systems technological ability has been proven within schools, colleges, healthcare environments, commercial properties as well as many other areas. TECHNICAL DETAILS • MATERIAL: »» GRP Glass fibre reinforced. »» Colour match gel coat finish. »» Trilayer Weather Protection. • OPTIONS: »» Colours; Available in any RAL or BS 4800 colour (Excludes RAL & BS metallic finishes). »» Truncated Capping (to suit specified pitch). »» Modified & extended skirt arrangements (to suit specified roof pitch and alternate upstand arrangements, on request). »» Acoustic foam (25 mm, 50 mm). • GUARANTEE: »» 10 year limited warranty. WIRING DETAILS • Cable Specification: »» »» Farnell: 1190282. »» »» RS: 660-4087. »» Electrical Wholesaler »» »» Reference: 16-2-3A. »» Number of Cores: 3. »» »» »» CSA: 0.5 mm². Screened: No. Voltage Rating: 440Vac. Current Rating: 2.5A. Core Strands: 16/0.2 mm. Outside Dia: 6.2 mm. Insulation Material: PVC. Page 52 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com WINDCATCHER CLASSIC (Oval) GENERAL DESCRIPTION WINDCATCHER systems WINDCATCHER CLASSIC BESPOKE (BSK) The WINDCATCHER CLASSIC is an energy free natural ventilation system encompassing the benefits of both top-down and passive stack ventilation. The system consists of an external louvre protected internally by a Trilayer Weather Protection and internally divided. The simple, but effective design of the system provides fresh air during the daytime as well as night-time cooling. When coupled with Monodraught’s iNVent control system (or similar BMS), and operated under Monodraught proven strategy, the system is capable of providing temperature and CO2 demand controlled ventilation, by means of energy efficient motorised volume control dampers. Due to the flexibility of the WINDCATCHER CLASSIC BSK, the system can be tailored to suit the needs of almost any area. The flexibility of the design of the system also allows for it to fit with almost any building design providing a seamless look or a striking effect. Whatever is required the WINDCATCHER CLASSIC BSK can be made to exacting requirements. TECHNICAL DETAILS • MATERIAL: »» GRP Glass fibre reinforced. »» Colour match gel coat finish. »» Trilayer Weather Protection. • OPTIONS: »» Colours; Available in any RAL or BS 4800 colour (Excludes RAL & BS metallic finishes). »» Truncated Capping (to suit specified pitch). »» Modified & extended skirt arrangements (to suit specified roof pitch and alternate upstand arrangements, on request). »» Acoustic foam (25 mm, 50 mm). • GUARANTEE: »» 10 year limited warranty. WIRING DETAILS • Cable Specification: »» Farnell: 1190282. »» RS: 660-4087. »» Electrical Wholesaler Reference: 16-2-3A. »» Number of Cores: 3. »» CSA: 0.5 mm². »» »» »» »» »» »» Screened: No. Voltage Rating: 440Vac. Current Rating: 2.5A. Core Strands: 16/0.2 mm. Outside Dia: 6.2 mm. Insulation Material: PVC. Page 53 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com WINDCATCHER CLASSIC (Bespoke) GENERAL DESCRIPTION WINDCATCHER systems WINDCATCHER HERITAGE Sizes available: 95, 125, 155, 185, 225. The WINDCATCHER HERITAGE is an energy free natural ventilation system encompassing the benefits of both top-down and passive stack ventilation. The system consists of an external louvre protected internally by a Trilayer Weather Protection and internally divided. In addition to the standard WINDCATCHER components, the HERITAGE systems visual construction enables it to fit aesthetically with many traditional building styles, whilst providing fresh air during the daytime as well as night‑time cooling. When coupled with Monodraught’s iNVent control system (or similar BMS), and operated under Monodraught proven strategy, the system is capable of providing temperature and CO2 demand controlled ventilation, by means of energy efficient motorised volume control dampers. Due to the flexibility of the WINDCATCHER HERITAGE, the system can be tailored to suit the needs of almost any area. The systems technological ability has been proven within schools, colleges, healthcare environments, commercial properties as well as many other areas. TECHNICAL DETAILS • MATERIAL: »» GRP Glass fibre reinforced. »» Colour match gel coat finish. »» Trilayer Weather Protection. • OPTIONS: »» Colours; Available in any RAL or BS 4800 colour (Excludes RAL & BS metallic finishes). »» Top finial (Optional), weathervane, clock face. »» Modified & extended skirt arrangements (to suit specified roof pitch and alternate upstand arrangements, on request). »» Acoustic foam (25 mm, 50 mm). • PERFORMANCE: »» Fire – BS 476-3:2004 / BS 476-24:1987. »» Sound - BS EN 20140-10:1992. »» Power supply range; 19.2 – 28.8 V DC. 0 – 10 V. »» Power consumption; 2W @ nominal force, 0.4 W at rest, 4 VA (wire sizing). »» Actuating force; 10 Nm (for systems up to 155) & 20 Nm (for systems 155 and larger) @ nominal voltage. Running time; 150 s / 95° (for volume control damper). »» IP54 rated actuator motor. • Page 54 • GUARANTEE: »» 10 year limited warranty. DIMENSIONS: »» Dim A: Capping Width. »» Dim B: Capping Height. »» Dim C: Louvre Height. »» Dim D: Skirt Height. »» Dim E: Trunk Length. »» Dim F: Trunk Width. »» 40 mm high louvre opening. »» 70 mm louvre pitch. Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com WINDCATCHER HERITAGE GENERAL DESCRIPTION PRODUCT VARIANTS WINDCATCHER Classic Systems (Circular) - Dimensions System Size Capping Capping Louvre Skirt Trunk Trunk Width Height Height Height Length Width Dim A Dim B Dim C Dim D# Dim E# Dim F 95 1000 466 460 220 278 600 125 1200 524 600 220 278 800 155 1400 563 740 220 278 1000 185 1600 652 880 220 278 1200 225 2000 675 1090 220 278 1500 Dim G 236 236 236 236 236 Weight No. of Louvres kg 55 7 79 8 118 11 158 13 215 16 Louvre free area / face m2 0.194 0.256 0.484 0.676 1.024 ## Dimension may change subject to roof construction, pitch, roof thickness, installaion method and upstand requirements. All dimension shown in mm. WIRING DETAILS • Cable Specification: »» Farnell: 1190282. »» RS: 660-4087. »» Electrical Wholesaler Reference: 16-2-3A. »» Number of Cores: 3. »» CSA: 0.5 mm². • »» »» »» »» »» »» Screened: No. Voltage Rating: 440Vac. Current Rating: 2.5A. Core Strands: 16/0.2 mm. Outside Dia: 6.2 mm. Insulation Material: PVC. • WINDCATCHER HERITAGE Heritage Page 55 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com SOLA-BOOST® Natural Ventilation Systems Page 56 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com SOLA-BOOST systems SOLA-BOOST CLASSIC (Square) Sizes available: 95, 125, 155, 185, 225. The SOLA-BOOST CLASSIC is an energy free natural ventilation system encompassing the benefits of both topdown and passive stack ventilation and DC solar powered fan controlled by Monodraught’s PowerTrack™ system. The system consists of an external louvre protected internally by a Trilayer Weather Protection and internally divided. The simple, but effective design of the system provides fresh air during the daytime as well as providing night-time cooling. A fan served by a central core provides intake or extract air (intake as standard), powered by solar panels situated at within the system capping. The fan is designed to provide the additional ventilation when it is need most, during summer, but with zero running cost. In order to maximise the performance of the solar powered fan, the system utilises the PowerTrack™ control system, which maximises the solar output to provide a smooth current from the solar panels and optimised fan flow. Due to the flexibility of the WINDCATCHER CLASSIC, the system can be tailored to suit the needs of almost any area. The systems technological ability has been proven within schools, colleges, healthcare environments, commercial properties as well as many other areas. TECHNICAL DETAILS • MATERIAL: »» GRP Glass fibre reinforced. »» Colour match gel coat finish. »» Trilayer Weather Protection. »» 225 mm Dia 24 V axial fan. »» 40 W Monocrystalline photovoltaic solar module • OPTIONS: »» Colours; Available in any RAL or BS 4800 colour (Excludes RAL & BS metallic finishes). »» Intake fan arrangement. Extract fan arrangement. »» Modified & extended skirt arrangements (to suit specified roof pitch and alternate upstand arrangements, on request). »» Acoustic foam (25 mm, 50 mm). • • PERFORMANCE: »» Fire – BS 476-3:2004 / BS 476-24:1987. »» Sound - BS EN 20140-10:1992. »» Power supply range; 19.2 – 28.8 V DC. 0 – 10 V. »» Power consumption; 2W @ nominal force, 0.4 W at rest, 4 VA (wire sizing). »» Actuating force; 10 Nm (for systems up to 155) & 20 Nm (for systems 155 and larger) @ nominal voltage. Running time; 150 s / 95° (for volume control damper). »» IP54 rated actuator motor. »» 260 l/s maximum fan flow. • Page 57 GUARANTEE: »» 10 year limited warranty. DIMENSIONS: »» Dim A: Capping Width. »» Dim B: Capping Height. »» Dim C: Louvre Height. »» Dim D: Skirt Height. »» Dim E: Trunk Length. »» Dim F: Trunk Width. »» 40 mm high louvre opening. »» 70 mm louvre pitch. Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com SOLA-BOOST CLASSIC (Square) GENERAL DESCRIPTION PRODUCT VARIANTS WINDCATCHER Classic Systems (Circular) - Dimensions System Size Capping Capping Louvre Skirt Trunk Trunk Width Height Height Height Length Width Dim A Dim B Dim C Dim D# Dim E# Dim F 95 706 339 460 150 278 600 125 906 395 600 150 278 800 155 1106 446 740 150 278 1000 185 1206 500 880 150 278 1200 225 1506 579 1090 150 278 1500 Dim G 49 74 155 157 214 Weight No. of Louvres kg 55 8 79 10 118 12 158 14 215 14 Louvre free area / face m2 0.140 0.252 0.396 0.572 0.896 ## Dimension may change subject to roof construction, pitch, roof thickness, installaion method and upstand requirements. All dimension shown in mm. WIRING DETAILS • Cable Specification: »» Farnell: 1190286. »» RS: 660-4096. »» Electrical Wholesaler Reference: 16-2-4A. »» Number of Cores: 4. »» CSA: 0.5 mm². »» »» »» »» »» »» Screened: No. Voltage Rating: 440Vac. Current Rating: 2.5A. Core Strands: 16/0.2 mm. Outside Dia: 6.7 mm. Insulation Material: PVC. • SOLA-BOOST CLASSIC Monodraught provides a 10m long Cat 5E network cable, as standard, for connecting to wall mounted controller. Should additional length be required, these must be straight wired to TIA/ EIA-568-B RJ45 wiring standard (T-568B at both ends). Page 58 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com WINDCATCHER systems TRILAYER WEATHER PROTECTION (Square) Monodraught’s TriLayer Weather Protection combines the use of the WINDCATCHER Classic’s external louvre bank, anti bird mesh and Rain Trap Louvre feature with an internal fibre mesh to protect against extreme weather conditions and is supplied as a standard but is also suitable for retro fit installation. The system assists in preventing snow ingress into Monodraught’s WINDCATCHER Classic systems by averting it before it reaches the trunk of the system and channelling it back down the Rain Trap louvre. The TriLayer Weather Protection system has been proven to be effective against simulated fine particle blizzard conditions. TECHNICAL DETAILS • MATERIAL: »» Fibre Glass with PVC Coating with a fine mesh. »» Charcoal colour. »» 27 mm x 12 mm Aluminium frames with rubber spline. • OPTIONS: »» Frames can have a maximum width of 1000 mm. Please note some systems may have an internal support frame that may require the frame to be split into two smaller frames. Widths of over 1000 mm will also require the frame to be split into two. »» Frames can have a maximum height of 2400 mm. Heights of over 2400 mm will require the frame to be split into two. • GUARANTEE: »» 10 year warranty. • PERFORMANCE: »» Free Area of 66 %. Securing Rivot Detail A Anti Bird Mesh Louvre Mesh Frame Rain Trap Louvre Page 59 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com TRILAYER WEATHER PROTECTION GENERAL DESCRIPTION COOL-PHASE® Natural Cooling Systems Page 60 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com Low Energy Cooling and Ventilation Unit COOL-PHASE GENERAL DESCRIPTION COOL-PHASE uses a thermal energy store utilising a Phase Change Material (PCM) in combination with an intelligently controlled Air Handling Unit to actively ventilate and cool the building. The COOL-PHASE system can maintain temperatures within the comfort zone, while radically reducing energy consumption by up to 90%, compared to a conventional cooling system. Unlike conventional cooling approaches, COOL-PHASE uses no refrigerants making it an environmentally sound solution to cooling our buildings. TECHNICAL DETAILS • MATERIAL: »» Steel rectangular section frame (ALLOY STEEL ERW BS6323). »» Aluminium folded sheet (EN AW5251 H22). »» Thermal moulded plastic. »» Phenolic foam insulation board (CFC/HCFC – free and ODP). • PERFORMANCE: »» Normal ventilation rate of approximately 0.1 to 0.28 m³/s. »» Maximum ventilation rate of approximately 0.35 m³/s. »» Thermal energy storage: 8 kWh. • OPTIONS: »» Fascia version for suspension below ceiling or false ceiling version supplied with fittings for installation in ceiling void. »» Powder coated white, alternative colours available on request. • DIMENSIONS: »» 4000 x 800 x 400 mm (for suspended system with fascias). »» System dimensions vary for installation above false ceiling. »» Minimum ceiling void (if mounting within void): 500 mm. »» Weight: 375 kg. • SYSTEM REQUIREMENTS: »» Connection to clean outside air source, inlet to be positioned away from sources of pollution / heating. »» Inlet: A suitable roof cowl or minimum 500 x 500 mm weather proof louvre with bird guard. »» Filtration: G4 300 x 400 x 500 mm bag filter, filter box & access hatch. »» Minimum supply duct size: 400 x 300 mm. »» Exhaust: internal or external grille specified to suit. Page 61 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com COOL-PHASE COOL-PHASE® is a low energy cooling and ventilation system that creates a comfortable, fresh and healthy indoor environment and reduces the running costs of buildings. ACOUSTIC PERFORMANCE Specific Fan Power & Fan Curve Ventilation and specific fan power calculated for air passing through heat exchanger, direct ventilation rates will be higher and therefore correspond with improved specific fan power ratings. 500 Ventilation rate [m3/h] Fan power [W] SFP [W/l/s] 320 1152 87 0.27 286 1030 72 0.25 250 900 58 0.23 227 817 46 0.20 200 720 35 0.18 170 612 26 0.15 125 450 19 0.15 Fan Speed 26% 450 Fan Speed 30% Fan Speed 34% 400 Fan Speed 38% 350 Pressure [PA] Ventilation rate [l/s] Fan Speed 42% Fan Speed 46% 300 Fan Speed 50% Fan Speed 60% 250 Fan Speed 80% 200 Fan Speed 100% 150 100 50 0 50 100 150 200 250 300 350 400 450 500 Flow [l/s] System: 6 m duct run, 90° bend, 2 x PCM modules, 300 x 400 mm G4 bag filter, 450 x 450 mm weather louvre. ACOUSTIC PERFORMANCE Sound power levels for the Cool-Phase AHU with fascia and in normal operating mode for different fan speeds. Sound Power Levels of the AHU with fascias Frequency (Hz) 63 125 250 500 1000 2000 4000 8000 Fan speeds 26% 53.3 49.7 52.9 46.4 41.0 30.8 21.4 23.2 34% 57.5 57.8 57.0 53.6 46.9 42.2 30.1 24.2 42% 53.5 68.2 62.0 57.0 53.3 48.6 38.6 27.1 Page 62 50% 56.0 79.3 66.3 62.8 59.0 53.3 46.7 34.9 60% 60.3 83.4 72.9 69.4 63.6 58.7 54.0 42.8 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com CONTROLS AND USER INTERFACE • • • • • • • Wall mounted user controls with room temperature, humidity and CO2 sensors. COOL-PHASE control system including temperature and humidity sensors. Master / slave mode to control multiple units in a single zone. Optional connections to compatible window, natural ventilation (eg. WINDCATCHER® natural ventilation system) or heating systems. Optional ‘traffic light’ indicator for windows. Inhibit input to enable / disable COOL‑PHASE system from BMS or Fire Alarm circuit. Single digital on / off output to be used in one of the following modes: »» Heating: The COOL-PHASE system will signal to the BMS to turn on heating when temperatures fall below a preset level. »» Cooling: The COOL-PHASE system will signal to the BMS to turn on a secondary cooling system when temperatures rise above a preset level. »» The COOL-PHASE system will signal to the BMS when there is a fault in the system. WIRING REQUIREMENTS • • • • Single phase mains with switched 5A fuse spur supply. KLIK PCR2000 socket, positioned within 1 m from AHU footprint. CAT 5E network cable between unit and user interface. CAT 5E network cable between slave and master units (as required). PCM Heat Exchanger External Air Direct Ventilation Re-circulated Air Page 63 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com PRODUCT VARIANTS COOL-PHASE Unit about False Ceiling Air Handling Unit (AHU) Thermal Battery Module Ceiling Tile Diffusers Page 64 Recirculation Grille Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com COOL-PHASE Unit with Fascias Duct Diffuser Air Handling Unit (AHU) Thermal Battery Module Page 65 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com Others HEAT HARVESTER 5/25, 8/35, 12/75 Sizes available: 5/25, 8/35, 12/75 Heat Harvester systems are a revolutionary de-stratification fan as they thermally equalize the air temperature in an enclosed space. The significance of this is that the system prevents all the hot air in the space rising to the ceiling and all the cold air sinking to the most important area, ie. the floor. The Heat Harvester system can also be used in a cooled air conditioned environment to equalize the temperature. The Heat Harvester system is suitable for any buildings, and can suit ceiling heights ranging from 2.5–31 m. The system is available as a free hanging unit. TECHNICAL DETAILS • MATERIAL: »» Outer shell recyclable Polycarbonate/ABS plastic resin. »» Inner Stator recyclable ABS. »» All materials Fire Rated 5VA materials. • PERFORMANCE 5/25: »» Volume Flow Rate of 126 l/s. »» Can achieve less than a 1°C temperature differential between floor and ceiling. »» Costs less than 10p a day to run 240 V AC with 25 W power consumption. • PERFORMANCE 8/35: »» Volume Flow Rate of 150 l/s. »» Can achieve less than a 1°C temperature differential between floor and ceiling. »» Costs less than 10p a day to run 240 V AC with 35 W power consumption. • PERFORMANCE 12/75: »» Volume Flow Rate of 238 l/s. »» Can achieve less than a 1°C temperature differential between floor and ceiling. »» Costs less than 25p a day to run 240 V AC with 75 W power consumption. • DIMENSIONS 5/25: »» Maximum height is 560 mm. »» Maximum Dia is 330 mm. »» Weight 5.4 kg. »» Free hanging units to be installed 300mm – 600mm below ceiling level. Page 66 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com HEAT HARVESTER GENERAL DESCRIPTION • DIMENSIONS 8/35: »» Maximum height is 560 mm. »» Maximum Dia is 330 mm. »» Weight 5.4 kg. »» Free hanging units to be installed 300mm – 600mm below ceiling level. • DIMENSIONS 12/75: »» Maximum height is 610 mm. »» Maximum Dia is 380 mm. »» Weight 6.4 kg. »» Free hanging units to be installed 300mm – 600mm below ceiling level. ELECTRICAL DATA Model Volts Hertz Watts RPM CFM 5/25 8/35 12/75 230 230 230 50 50 50 25 35 75 1230 1650 - 405 1072 - Page 67 Flow Rate l/s 125 150 238 dB(A) 30 34 40 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com CONTROL SYSTEMS Page 68 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com CONTROL systems iNVent (IN0031) GENERAL DESCRIPTION TECHNICAL DETAILS • MATERIAL: »» Front Cover: Acrylic capped ABS. • OPERATING CONDITIONS: »» 0 - 40 oC. »» 10 – 80 % RH non-condensing. • MOUNTING: »» Unit is designed to be wall mounted in a decentralised location within the building close to the zones it is controlling like a storage cupboard or above a suspended ceiling. • POWER SUPPLY: »» 24V DC @ 70 mA Nom. »» Supplied with SMPS for converting 240V AC to 24V DC @ 2.5A requiring connection to a 3/5A switched spur. (The three components supplied are: IN0032 PSU, IN0033 IEC Plug cable and IN0034 PSU cover for wall mounting.) »» The iNVent can supply up to a total of 2A from the 24VDC supply to field devices. • DIMENSIONS: »» 255 x 385 x 40 mm. • TERMINALS: »» Cable size 1 mm2 max. »» Cable size 0.5 mm2 multi-strand recommended. Page 69 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com iNVent (IN0031) The iNVent X-AIR is the latest version of the Monodraught ICS4 for natural ventilation control. The primary function of this system is to control up to four zones each consisting of up to three WINDCATCHER® natural ventilation systems, or up to three SOLA-BOOST® solar assisted natural ventilation systems, both in either Classic or X-AIR guises when utilised with the appropriate field sensing and control components. The system can also be used to control zones of SUNCATCHER® natural ventilation and daylight systems and VENTSAIR facade and roof mounted ventilation terminals. DIGITAL INPUTS INPUT Rain TYPE (volt free contact closure detection) Heat Fire Competition Switch Open (volt free contact closure detection) (volt free contact closure detection) (volt free contact closure detection) Competition Switch Close (volt free contact closure detection) USED WITH Rain Sensor Kit. (IN0043, IN004 and IN0040). BMS input (VF-NO Contact). BMS/Fire Alarm input (VF-NO Contact). Monodraught Competition Switch IN0046 or BMS input (VF-NO contact). Monodraught Competition Switch IN0046 or BMS input (VF-NO contact). ANALOGUE INPUTS INPUT Zone 1 Controller Zone 2 Controller Zone 3 Controller Zone 4 Controller External Temperature TYPE 0-10V DC 0-10V DC 0-10V DC 0-10V DC 0-10V DC Zone 1 Active Louvre Feedback Zone 2 Active Louvre Feedback Zone 3 Active Louvre Feedback Zone 4 Active Louvre Feedback 0-10V DC 0-10V DC 0-10V DC 0-10V DC USED WITH N0001 WINDCATCHER Temperature Controller, IN0002 WINDCATCHER Temperature and CO2 controller or IN0003 SOLA-BOOST Temperature Controller/IN0004 SOLA-BOOST Temperature and CO2 Controller with one of the following Powertracks: IN0020 Standard, IN0021 Master, IN0060 Standard X-AIR or IN0061 Master X-AIR. IN0048 External Temperature Sensor. Supplied as Standard. Connected to Master Active Louvre Drive Motor via WINDCATCHER X-AIR Damper Cable or SOLA-BOOST X-AIR Powertrack Cable. ANALOGUE OUTPUTS OUTPUT Zone 1 Damper Zone 2 Damper Zone 3 Damper Zone 4 Damper Zone 1 Active Louvre Zone 2 Active Louvre Zone 3 Active Louvre Zone 4 Active Louvre TYPE 2-10V 2-10V 2-10V 2-10V 2-10V 2-10V 2-10V 2-10V USED WITH WINDCATCHER / WINDCATCHER X-AIR or one of the following Powertracks: IN0020 Standard, IN0021 Master, IN0060 Standard X-AIR or IN0061 Master X-AIR. Connected to WINDCATCHER X-AIR Zone with Damper or to SOLA-BOOST X-AIR Powertrack with Damper, Controller and Feedback. Page 70 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com DIMENSIONAL DRAWING Monodraught Limited reserves the right to change the product specification or withdraw the product without prior notification. Page 71 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com CONTROL systems WINDCATCHER CONTROLLER (IN0001 and IN0002) The WINDCATCHER controller is designed to be mounted in a zone containing natural ventilation products with controllable dampers, like WINDCATCHER X-AIR among others. The product provides temperature local override control along with temperature sensing and even CO2 measurement on the IN0002 variant all encoded onto a single 0-10V analogue output. Overrides are timed and configurable at time of commissioning to 20 minutes, 1 hour or 3 hours. The CO2 senor in the IN0002 version features an Automatic Background Calibration which will recalibrate the sensor back to a background level during unoccupied periods to cancel sensor drift and maintain accuracy over the typical product lifespan. This unit is particularly suitable for applications requiring demand controlled ventilation and is recommended for use Monodraught iNVent Systems or third party BMS systems. TECHNICAL DETAILS • MATERIAL: »» Enclosure moulded in flame retardant PC/ABS. • OPERATING CONDITIONS: »» 10 - 40 oC. »» 10 – 80% RH non-condensing. • MOUNTING: »» To be wall mounted 1.2 - 2.1 m from floor, out of direct sunlight. • POWER SUPPLY: »» 24V DC @ 15mA Nom. • DIMENSIONS: »» 100 x 150 x 40 mm. • TERMINALS: »» Cable size 1 mm2 max. »» Cable size 0.5 mm2 multi-strand recommended. Page 72 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com WINDCATCHER CONTROLLER GENERAL DESCRIPTION OUTPUTS (in order of priority on single output) OUTPUT Temperature CO2* Override Open Override Close VOLTAGE RANGE 0 - 10V 8.6 - 9.2V 9.2 - 10V 0 - 0.5V MEASURED RANGE 10 - 29 oC Threshold breached** Timed button Timed button ACCURACY +/ -1 oC +/-100 ppm N/A N/A DIMENSIONAL DRAWING Monodraught Limited reserves the right to change the product specification or withdraw the product without prior notification. Page 73 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com CONTROL systems SOLA-BOOST CONTROLLER (IN0003 and IN0004) The SOLA-BOOST Controller is designed to be mounted in a zone containing Monodraught SOLA-BOOST systems and needs to be used with the correct Powertrack unit for the systems, one of: IN0020 Standard, IN0021 Master, IN0060 Standard X-AIR or IN0061 Master X-AIR. The product provides temperature local override control along with temperature sensing and even CO2 measurement on the IN0004 variant all communicated over the bespoke RS-485 Communications to the Powertrack and then encoded onto a single 0-10V analogue output. Overrides are timed and configurable at time of commissioning to 20 minutes, 1 hour or 3 hours. The CO2 senor in the IN0004 version features an Automatic Background Calibration which will recalibrate the sensor back to a background level during unoccupied periods to cancel sensor drift and maintain accuracy over the typical product lifespan. This unit is particularly suitable for applications requiring demand controlled ventilation and is recommended for use Monodraught iNVent Systems or third party BMS systems. TECHNICAL DETAILS • MATERIAL: »» Enclosure moulded in flame retardant PC/ABS. • OPERATING CONDITIONS: »» 10 - 40 oC. »» 10 – 80% RH non-condensing. • MOUNTING: »» To be wall mounted 1.2 - 2.1 m from floor, out of direct sunlight. • POWER SUPPLY: »» 24V DC @ 15mA Nom. (Supplied from Powertrack down CAT5e). • DIMENSIONS: »» 100 x 150 x 40 mm. • TERMINALS: »» RJ45 Socket for Straight wired CAT5e Patch lead to the Powertrack unit. Page 74 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com SOLA-BOOST CONTROLLER GENERAL DESCRIPTION OUTPUTS OUTPUT Temperature CO2* Override Open Override Close VOLTAGE RANGE 0 - 10V 8.6 - 9.2V 9.2 - 10V 0 - 0.5V MEASURED RANGE 10 - 29 oC Threshold breached** Timed button Timed button ACCURACY+ +/ -1 oC +/-100 ppm N/A N/A DIMENSIONAL DRAWING Monodraught Limited reserves the right to change the product specification or withdraw the product without prior notification. Page 75 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com CONTROL systems RAIN SENSOR KIT (IN0043, IN0042, IN0040) The Rain Sensor Kit comprises of: IN0043 IP55 Din rail Enclosure for liquid detection module, IN0042 Liquid detection module and IN0040 Rain Sensor. The kit provides detection of rain through a volt-free changeover relay output. The Rain Sensor incorporates a heater to dry the sensor post sensing event and to prevent erroneous detection of mist etc. This kit is suitable for most applications requiring precipitation detection and is recommended for use with Monodraught iNVent control systems or third party BMS solutions. TECHNICAL DETAILS • MATERIAL: »» IN0043: Flame Retardant Polystyrene (Polycarbonate Door). »» IN0042 and IN0040: Enclosures are manufactured from Flame Retardant Polycarbonate. • OPERATING CONDITIONS: »» -10 to + 40 oC. »» 10 – 80% RH non-condensing (IN0040 0 – 100% RH with IP65 gland). • MOUNTING: »» Liquid detection module (IN0042) to be mounted inside the building and within the supplied enclosure (IN0043). »» Rain Sensor (IN0040) to be mounted on the roof with the sensing element facing upwards, clear of any obstructions like pier walls or higher buildings in all directions for at least 20 m. • DIMENSIONS: »» IN0043: 100 x 150 x 96 mm. »» IN0042: 90 x 55 x 58 mm. »» IN0040: 75 x 60 x 36 mm. • TERMINALS: »» Cable size 2 mm2 max. »» 240V cables to be sized to suit spur rating. »» Cable size 0.5 mm2 multi-strand recommended for all low voltage. • PROTECTION: »» IN0043: IP55; IN0042: IP20; IN0040: IP65. • POWER SUPPLY: »» IN0042: 240V AC +/- 15% @ 40 mA Max. Page 76 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com RAIN SENSOR KIT GENERAL DESCRIPTION OUTPUT (FROM IN0042) OUTPUT Rain RELAY TYPE Changeover (NO mode commonly utilised.) DELAY TO ACTIVE 6 Seconds RELAY RAITING 240V 3A Max. (Low Voltage Digital Input Preferred.) CONNECTION DRAWING Monodraught Limited reserves the right to change the product specification or withdraw the product without prior notification. Rain Sensor Liquid Detection Module To Control System (Digital Input / Contact Closure Detection) 240 V Switched Fused Spur Page 77 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com CONTROL systems ROOM TEMPERATURE SENSOR (IN0045) The IN0045 is a room temperature measurement device with a range of 0 – 40 oC. This unit is suitable for most applications requiring temperature controlled ventilation and is recommended for use with Monodraught iNVent control systems, third party BMS or Monodraught custom control systems such as our BACnet/IP solutions. TECHNICAL DETAILS • MATERIAL: »» Enclosure is manufactured from Flame Retardant Polycarbonate. • OPERATING CONDITIONS: »» 0 - 40 oC. »» 10 – 80% RH (Non-Condensing). • MOUNTING: »» To be wall mounted 1.2 - 2.1 m from floor out of direct sunlight (1.5m recommended). • POWER SUPPLY: »» 24V DC @ 20mA Nom. • DIMENSIONS: »» 80 x 80 x 29 mm. • TERMINALS: »» Cable size 1 mm2 max. »» Cable size 0.5 mm2 multi-strand recommended. Page 80 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com ROOM TEMPERATURE SENSOR GENERAL DESCRIPTION DIMENSIONAL DRAWING AND CONNECTIONS Monodraught Limited reserves the right to change the product specification or withdraw the product without prior notification. Page 81 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com CONTROL systems EXTERNAL TEMPERATURE SENSOR (IN0048) The external temperature measurement device with a range of -10 to + 40 oC, has an IP65 rating and the sensor is encapsulated within this enclosure to reduce the risk of damage from high humidity or condensing conditions. This unit is suitable for most applications requiring ventilation control linked to external temperature and is recommended for use with Monodraught iNVent control systems or third party BMS solutions. TECHNICAL DETAILS • MATERIAL: »» Enclosure is manufactured from Flame Retardant Polycarbonate. • OPERATING CONDITIONS: »» -50 to + 70 oC. »» 0 – 100% RH (When used with IP65 gland). • MOUNTING: »» To be fixed to a north facing wall free from the effects of direct sunlight or shaded by a soffit or similar. • POWER SUPPLY: »» 24V DC @ 20mA Nom. • DIMENSIONS: »» 75 * 60 * 36 mm. • TERMINALS: »» Cable size 1 mm2 max. »» Cable size 0.5 mm2 multi-strand recommended. Page 82 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com EXTERNAL TEMPERATURE SENSOR GENERAL DESCRIPTION OUTPUTS (in order of priority on single output) OUTPUT Temperature VOLTAGE RANGE 0 - 10V MEASURED RANGE -10 to + 40 oC ACCURACY +/- 0.5 oC DIMENSIONAL DRAWING Monodraught Limited reserves the right to change the product specification or withdraw the product without prior notification. Page 83 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com BUILDING SIMULATION Daylight Simulation & Thermal Modelling Page 84 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com Building Simulation DAYLIGHT SIMULATION Monodraught have a range of daylight design tools available to simulate the anticipated conditions experienced within a given building as a result of the installation of our natural daylight systems. IES VE-PRO There are two daylight simulation packages available in the VE-Pro suite that are used as design tools by Monodraught’s Design Engineers – FlucsDL and RadianceIES. • FLUCSDL: The FlucsDL module enables the designer to determine the indoor daylight conditions in different rooms within a building model to ascertain the daylight factors and light levels experienced within a space. Monodraught have experimentally determined the design parameters associated with our natural daylight systems, herefore our Design Engineers have the ability to model physical representations of our systems and the subsequent daylight conditions achieved in the areas that they are intended to be installed within. • RADIANCE IES: The RadianceIES module enables our Design Engineers to analyse the daylight levels in a room that has Monodraught natural daylight systems installed within it. The programme provides the user with the capability to produce photo-realistic renders of the internal spaces, which can also be used to ascertain the exact light levels within a room. The module can also link with the thermal simulation modules of the VE-Pro suite, using daylight dimming profiles for lighting gains to enhance the thermal comfort for occupants. DIALUX The package is renowned for its accuracy in modelling daylight and the visualizations that can be produced give the client an insight into the quality of light that can be achieved within a space by Monodraught natural daylight systems. Page 85 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com DAYLIGHT SIMULATION GENERAL DESCRIPTION LUX PLOTTER The LUX plotter is a mathematical model developed for Monodraught by the University of Liverpool for determining the size and number of Monodraught SUNPIPE® natural daylight systems required to achieve a desired lux level in a given space. Page 86 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com Building Simulation THERMAL MODELLING Monodraught have a range of thermal modelling tools available to simulate the anticipated thermal conditions experienced as a result of the installation of our natural ventilation and low energy cooling and ventilation systems within a given building. • Dynamic Thermal Simulation: A dynamic thermal simulation encompasses all the design parameters that influence the way in which a building responds to the external environment. Users can create a model that replicates the exact physical form of a building, incorporating all aspects of the construction specification and the internal heat gains to simulate the anticipated internal conditions in accordance with industry recognised external weather data. There are three dynamic simulation packages currently used by Monodraught for the thermal modelling of buildings: IES VE-PRO Integrated Environmental Solutions (IES) are the global leaders in the field of building performance simulation and their package, the IES <Virtual Environment>, is widely recognised within the industry for its ability to enhance the sustainable building design process. VE-Pro is the most powerful suite of building performance analysis tools available, and it is therefore the primary design tool used by all of Monodraught’s Design Engineers. The ApacheSim thermal simulation engine, supported by the Suncast and Macroflo modules, complies with the requirements of CIBSE Application Manual AM11, and the software is recognised as one of the most accurate means of modelling natural ventilation strategies using bulk air flow simulation. • Natural Ventilation Design Consultancy: Monodraught offer a complete design service for our natural ventilation systems. If the necessary information to compile a thermal model is made available, our Design Engineers will construct a complete dynamic thermal model of a building for a specific project in order to ascertain the size and number of systems required for a particular natural ventilation or low energy cooling and ventilation strategy. This service is provided free of charge, and we issue detailed proposal documents that outline the input design parameters used for the model and the resultant compliance with the associated thermal comfort criterion for our proposed strategy. Alternatively, our design engineers also have the ability to simulate our systems using IES models that have been provided by an external party. The advantage of this approach is that the client can pre-define the input parameters in their model, thus ensuring that our Design Engineers are using thermal and construction templates that accurately reflect the building fabric and its internal environment. Page 87 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com THERMAL MODELLING GENERAL DESCRIPTION • IES Performance Components: To help architects and consultants deliver low maintenance, energy efficient designs within the built environment, Monodraught have collaborated with IES to develop Performance Components – a revolutionary way of modelling natural ventilation systems using the Virtual Environment Suite. Conventional modelling of wind tower systems involves constructing a 3D representation of the WINDCATCHER within a specific model and assigning each face with a performance factor which quantifies its ability to ‘catch’ the air. This process is, however, often misinterpreted by external parties who wish to simulate wind tower systems due to variations between software packages and the manufacturers of such systems being unable to provide the required input data for a particular model. Only now, with the launch of performance components, will there be a defined method for modelling wind tower natural ventilation systems that will soon come to be recognised across the building design industry. The VE-Pro suite now features a library of predefined 3D component representations of our systems that can be dragged easily from a catalogue of products onto a building model constructed within the virtual environment. The performance and energy savings can then be assessed in an open and transparent process by the client alone, thus building confidence in the application of WINDCATCHER natural ventilation systems and demonstrating the true capabilities and potential for natural and hybrid ventilation schemes. Each performance component replicates the shape, texture and colour of the associated WINDCATCHER system, with the performance characteristics and control strategies predefined to optimise the usability and efficiency of the tool. Users will find the simplicity of the ‘drag and drop’ feature rapidly decreases the modelling time typically associated with these types of systems. With each performance component already assigned the relevant construction templates, thermal templates, and flow profiles, they are ready to simulate as soon as they have been positioned in the model, allowing users the flexibility to explore the possibilities of natural ventilation as an alternative to a more conventional mechanical system. The analysis tools that are available in the VE-Pro suite provide the user with a visual insight into the performance of WINDCATCHER systems year round, and the authentic textures offer architects and designers a means of understanding the aesthetics of Monodraught systems and how best to integrate them into a building. Page 88 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com NAVENSYS The NAVENSYS thermal simulation software was developed by Monodraught to model natural ventilation strategies within buildings. The software has been built upon Monodraught’s forty years experience in manufacturing natural ventilation systems and 4 years of academic research by Brunel University. The NAVENSYS program is a simplified dynamic thermal simulation engine, requiring fewer inputs than the likes of an IES or a Tas model. This means it is a useful tool for sizing Monodraught natural ventilation and low energy cooling and ventilation systems during the early stages of a project, when full details of a building are not always readily available.The by NAVENSYS simulation software has been collaborated against performance data from the Tas thermal modeling software. Page 89 Monodraught Ltd Halifax House, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3SE T: +44 (0) 1494 897700 F: +44 (0) 1494 532465 E: info@monodraught.com W: www.monodraught.com