Untitled - Kent Euroclean
Transcription
Untitled - Kent Euroclean
IMPORTANT SAFEGUARDS Accidents due to misuse can only be prevented by those using the machine. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. WARNING ! To reduce the risk of fire, electric shock, or injury. Please read and follow all safety instructions and caution markings before using. This vacuum cleaner is designed to be safe when used to perform cleaning functions as specified. Should damage occur to electrical or mechanical parts, cleaner and / or accessory should be repaired by manufacturer or competent service station before using in order to avoid further damage to machine or physical injury to user. *To avoid electrical shock, use indoors only. *Disconnect cleaner before servicing and when not in use. Do not leave unattended cleaner plugged in. *Do not use with damaged cord or plug. Always grasp the plug when unplugging the machine. Do not unplug by pulling the cord.Do not handle plug or cleaner with wet hands. Turn off all controls before unplugging. *Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not run cleaner over cord. Keep cord away from heated surfaces. * Wind up the cord beginning at the machine and than store the cord hanging on the machine handle. *Keep hair, loose clothing, fingers and all parts of the body away from openings and moving parts. Do not put any objects into openings or use with opening blocked. Keep openings free of dust, lint, hair, and anything else that could reduce air flow. *Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes. *Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present. *Do not allow to be used as a toy. Close attention is necessary when used by or near children. *If cleaner is not working properly or has been dropped, damaged, left outdoors, or dropped into water, return it to a service center or dealer. *Use only as described in this manual and only with manufacturer’s recommended attachments. *The use of the HEPA-filter when picking up hazardous materials has not been evaluated by Underwriters Laboratories. *The use of this machine in conjunction with the pick-up of hazardous materials has not been investigated by UL. *Do not use unless filters and bag are in place. *Use extra care when using on stairs or irregular surfaces. *Connect to properly grounded outlet only. See Groundning instructions. BE SAFE AVOID POSSIBLE HAZARDS GENERAL INFORMATION This vacuum cleaner can be used for household or commercial use. BEFORE YOU PLUG IN YOUR CLEANER, check the rating plate located near the power switch, to see if the rated voltage agrees within 10% of the voltage available. DO NOT OIL The motor in your new cleaner is permanently lubricated and sealed. Do not oil the motor at any time. When the machine is not in use, store it standing on its wheels. For longer service life and safe use of your vacuum cleaner, we recommend the following guidelines: Your cleaner is designed to pick up dirt and dust particles and for water pick up. Avoid picking up hard or sharp objects with your cleaner to avoid clogging or possible motor damage. IMPORTANT! This machine is equipped with a specially designed cable, wich if damaged, must be replaced by a cable of the same type.These cables are avaliable at authorized service shops and must be installed by trained personnel. SAVE THESE INSTRUCTIONS 3 DESCRIPTION UZ 877 and UZ 878 are a series of wet and dry suction cleaners wherein the model designation is determined by the capacity of the container - 11 and 15 gallons resepectively. The cleaners are electrically grounded. The cleaners are designed for wet and dry cleaning. 1. Motor housing with float. (Suction cuts off when maximum water level is reached) 2. Hooks for cable and hose carrying. 3. Electrical panel 4. HEPA-filter 5. Float 6. Micro-filter 7. Pre-filter 8. Hose connection 9. Container- 11 gallons 10. Suction hose 11. Extension tube 12. Base unit for UZ 877 13. Nozzle 14. Brush insert 15. Rubber insert 16. Draincock (UZ878) 17. Container- 15 gallons 18. Base unit for UZ 878 NOTE! Inspect the float regularly for signs of damage. 5 ASSEMBLY 1. UZ 877- The ends of the handle are inserted into the holes in the base and secured by two socket head capscrews from below. The container is than placed on the base as in figure 1. UZ 878- The container is placed on the base as in figure 2. 2. The motor housing is placed on the container and secured with snapfasteners. 3.The hose is connected to the container via the inlet stub. Pull up the locking pin and insert the hose end. Then fit the extension tubes and nozzle as shown in figure 3. The hooks on top of the motor housing are for carrying the hose and the power cable. 3 6 FILTER The machines are fitted with three filters: 1.Pre-filter, traps coarse waste particles, the pre-filter should be changed regularly. 2. Micro filter, can be cleaned and re-used. 3. HEPA-filter, captures 99.97% of all dust particles 0.3 microns in size or larger. The pre-filter and micro filter are designed for use in both wet pick-up and dry pick-up applications. The filters are fitted as in figure. MOTOR TOP SEALING RING (already mounted on new HEPA-Filter.) HEPA-FILTER SCREW SEALING RING (already mounted on new HEPAfilter.) If the machine is used without HEPA-filter this sealing must be fitted on the under side of the motor top. SCREW FLOAT BASKET CPL. GASKET PRE-FILTER MICRO-FILTER CAP 7 LINER BAGS Poly liner bags are avaliable and one is supplied with each new machine. These are for the collection of dust. They are resistant to water and make emtying easier. These liners must be gathered together at the neck on removal. For wet pick-up only, liners are not recommended. Fitting 1. Switch the cleaner off and withdraw the plug. 2.Take the motorhousing off. 3. Fold the edge of the opening over the rim of the container, ensuring that the row of Ø5mm liner will be dra up against the filter holder. 4. Replace motor housing. SWITCHING ON The cleaners have two switch knobs on the left of the electrical panel. One for each motor. See fig. Switch number 1 starts the first motor. (Reduced power) Switch number 2 starts second motor . (Full power Normal position) 8 TO EMPTY 1. Switch the cleaner off and pull the plug out. 2. Disconnect the hose 3. Remove the motor housing. The cleaner can now be emptied in various ways depending on the type of base fitted. Alt. 1. See Figure 1 (UZ 878 only). Alt. 2. See Figure 2. Alt. 3. Wet pick-up only. The container can be emptied by opening the draincock at the bottom. See figure 3. (UZ 878 only). MAKE SURE THAT: • • • • • • • • • • The correct nozzle is used. Liners are used when necessary. Liners are replaced when about 2/3 full, or when cleaner suction is impaired. Liners are removed prior to wet pick-up. A chemical foam inhibitor is used to wet pick-up of lather building liquids. Pre-filter is changed regularly. Secondary (micro) filter is cleaned regularly. The cleaner is switched off prior to plugging in. The cleaner is switched off prior to to pulling the plug out. Should the cleaner not start - check circuit breakers. NOTE! Switch the machine off at once if liquid /foam begins to force its way out from the top of the motor. Clean the filter, the seal and the ball of the ball float at regular intervals. They can be accessed for cleaning purposes by unfastening the three screws which hold the float cage in position, and then removing the cage. 9 Kent/Euroclean © 2002 Printed in USA 14600 21st Avenue North Plymouth, MN, 55447-3408 www.eurocleanusa.com Phone: 800-334-1083 Fax: 866-261-4779