IMPORTANT SAFEGUARDS
Accidents due to misuse can only be
prevented by those using the machine.
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS.
WARNING !
To reduce the risk of fire, electric shock, or injury.
Please read and follow all safety instructions
and caution markings before using.
This vacuum cleaner is designed to be safe
when used to perform cleaning functions as
specified. Should damage occur to electrical or
mechanical parts, cleaner and / or accessory
should be repaired by manufacturer or
competent service station before using in order
to avoid further damage to machine or physical
injury to user.
*To avoid electrical shock, use indoors only.
*Disconnect cleaner before servicing and when
not in use. Do not leave unattended cleaner
plugged in.
*Do not use with damaged cord or plug. Always
grasp the plug when unplugging the machine.
Do not unplug by pulling the cord.Do not handle
plug or cleaner with wet hands. Turn off all
controls before unplugging.
*Do not pull or carry by cord, use cord as a
handle, close a door on cord, or pull cord around sharp edges or corners. Do not run cleaner
over cord. Keep cord away from heated
surfaces.
* Wind up the cord beginning at the machine
and than store the cord hanging on the machine
handle.
*Keep hair, loose clothing, fingers and all parts
of the body away from openings and moving
parts. Do not put any objects into openings or
use with opening blocked. Keep openings free
of dust, lint, hair, and anything else that could
reduce air flow.
*Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
*Do not use to pick up flammable or combustible
liquids such as gasoline or use in areas where
they may be present.
*Do not allow to be used as a toy. Close attention
is necessary when used by or near children.
*If cleaner is not working properly or has been
dropped, damaged, left outdoors, or dropped
into water, return it to a service center or dealer.
*Use only as described in this manual and
only with manufacturer’s recommended
attachments.
*The use of the HEPA-filter when picking up
hazardous materials has not been evaluated by
Underwriters Laboratories.
*The use of this machine in conjunction with the
pick-up of hazardous materials has not been
investigated by UL.
*Do not use unless filters and bag are in place.
*Use extra care when using on stairs or irregular
surfaces.
*Connect to properly grounded outlet only. See
Groundning instructions.
BE SAFE AVOID POSSIBLE HAZARDS
GENERAL INFORMATION
This vacuum cleaner can be used for household
or commercial use.
BEFORE YOU PLUG IN YOUR CLEANER,
check the rating plate located near the power
switch, to see if the rated voltage agrees within
10% of the voltage available.
DO NOT OIL The motor in your new cleaner is
permanently lubricated and sealed. Do not oil
the motor at any time.
When the machine is not in use, store it standing on its wheels.
For longer service life and safe use of your
vacuum cleaner, we recommend the
following guidelines: Your cleaner is designed to pick up dirt and dust particles and for
water pick up. Avoid picking up hard or sharp
objects with your cleaner to avoid clogging
or possible motor damage.
IMPORTANT!
This machine is equipped with a specially designed cable, wich if damaged, must be replaced
by a cable of the same type.These cables are
avaliable at authorized service shops and must
be installed by trained personnel.
SAVE THESE INSTRUCTIONS
3
DESCRIPTION
UZ 877 and UZ 878 are a series of wet and
dry suction cleaners wherein the model
designation is determined by the capacity of
the container - 11 and 15 gallons
resepectively. The cleaners are electrically
grounded. The cleaners are designed for wet
and dry cleaning.
1. Motor housing with float. (Suction cuts off
when maximum water level is reached)
2. Hooks for cable and hose carrying.
3. Electrical panel
4. HEPA-filter
5. Float
6. Micro-filter
7. Pre-filter
8. Hose connection
9. Container- 11 gallons
10. Suction hose
11. Extension tube
12. Base unit for UZ 877
13. Nozzle
14. Brush insert
15. Rubber insert
16. Draincock (UZ878)
17. Container- 15 gallons
18. Base unit for UZ 878
NOTE! Inspect the float regularly
for signs of damage.
5
ASSEMBLY
1. UZ 877- The ends of the handle are
inserted into the holes in the base and
secured by two socket head capscrews from
below. The container is than placed on the
base as in figure 1.
UZ 878- The container is placed on the base
as in figure 2.
2. The motor housing is placed on the
container and secured with snapfasteners.
3.The hose is connected to the container via
the inlet stub. Pull up the locking pin and
insert the hose end. Then fit the extension
tubes and nozzle as shown in figure 3.
The hooks on top of the motor housing are for
carrying the hose and the power cable.
3
6
FILTER
The machines are fitted with three filters:
1.Pre-filter, traps coarse waste particles, the
pre-filter should be changed regularly.
2. Micro filter, can be cleaned and re-used.
3. HEPA-filter, captures 99.97% of all dust
particles 0.3 microns in size or larger.
The pre-filter and micro filter are designed for
use in both wet pick-up and dry pick-up
applications.
The filters are fitted as in figure.
MOTOR TOP
SEALING RING
(already mounted on
new HEPA-Filter.)
HEPA-FILTER
SCREW
SEALING RING (already
mounted on new HEPAfilter.)
If the machine is used
without HEPA-filter this
sealing must be fitted on the
under side of the motor top.
SCREW
FLOAT BASKET CPL.
GASKET
PRE-FILTER
MICRO-FILTER
CAP
7
LINER BAGS
Poly liner bags are avaliable and one is
supplied with each new machine. These are
for the collection of dust. They are resistant to
water and make emtying easier. These liners
must be gathered together at the neck on
removal. For wet pick-up only, liners are not
recommended.
Fitting
1. Switch the cleaner off and withdraw the
plug.
2.Take the motorhousing off.
3. Fold the edge of the opening over the rim of
the container, ensuring that the row of Ø5mm
liner will be dra up against the filter holder.
4. Replace motor housing.
SWITCHING ON
The cleaners have two switch knobs on the
left of the electrical panel. One for each motor.
See fig.
Switch number 1 starts the first motor.
(Reduced power)
Switch number 2 starts second motor .
(Full power Normal position)
8
TO EMPTY
1. Switch the cleaner off and pull the plug out.
2. Disconnect the hose
3. Remove the motor housing.
The cleaner can now be emptied in various
ways depending on the type of base fitted.
Alt. 1. See Figure 1 (UZ 878 only).
Alt. 2. See Figure 2.
Alt. 3. Wet pick-up only. The container can be
emptied by opening the draincock at the
bottom. See figure 3. (UZ 878 only).
MAKE SURE THAT:
•
•
•
•
•
•
•
•
•
•
The correct nozzle is used.
Liners are used when necessary.
Liners are replaced when about 2/3 full,
or when cleaner suction is impaired.
Liners are removed prior to wet pick-up.
A chemical foam inhibitor is used to wet
pick-up of lather building liquids.
Pre-filter is changed regularly.
Secondary (micro) filter is cleaned
regularly.
The cleaner is switched off prior to
plugging in.
The cleaner is switched off prior to to
pulling the plug out.
Should the cleaner not start - check
circuit breakers.
NOTE! Switch the machine off at once if
liquid /foam begins to force its way out
from the top of the motor. Clean the filter,
the seal and the ball of the ball float at
regular intervals. They can be accessed
for cleaning purposes by unfastening the
three screws which hold the float cage in
position, and then removing the cage.
9
Kent/Euroclean
© 2002 Printed in USA
14600 21st Avenue North
Plymouth, MN, 55447-3408
www.eurocleanusa.com
Phone: 800-334-1083
Fax: