WILBER-CLATONIA PUBLIC SCHOOLS 900 SOUTH FRANKLIN
Transcription
WILBER-CLATONIA PUBLIC SCHOOLS 900 SOUTH FRANKLIN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 V WILBER-CLATONIA HIGH SCHOOL ROOF REPLACEMENT & EXTERIOR RENOVATION U T ARCHITECT BAHR VERMEER HAECKER ARCHITECTS 440 N 8TH ST STE 100 LINCOLN NE 68508 V 402 475 4551 F 402 475 0226 bvh.com WILBER-CLATONIA PUBLIC SCHOOLS 900 SOUTH FRANKLIN WILBER, NE 68465 S R BVH PROJECT NO. F16127 P FINAL CONTRACT DOCUMETS APRIL 18, 2016 N M L K REVISIONS SCHEDULE MARK J 6 General Notes Symbols Legend Index of Drawings GENERAL NOTES APPLY TO ALL TRADES WORKING ON THE PROJECT. ASI #3 G1.0 SECTION REFERENCE COVER SHEET XX ARCHITECTURAL DRAWINGS X ELEVATION REFERENCE CONTRACTOR(S) SHALL EXERCISE ALL REASONABLE PRECAUTIONS FOR THE PROTECTION OF PERSONS AND PROPERTY ON THE SITE. SAFETY PROVISIONS OF APPLICABLE LAWS AND BUILDING AND CONSTRUCTION CODES SHALL BE OBSERVED. XX AD1.1 AD1.2 A1.1 A1.2 F CONTRACTOR SHALL SEAL ALL PENETRATIONS THROUGH FLOORS, FIREPROOFING, SHAFT ENCLOSURES, ROOFS, PERMANENT PARTITIONS, FIREWALLS, SMOKE CURTAINS, AREA SEPARATION WALLS, STAIR ENCLOSURES, EXTERIOR WALL, AND OTHER FIRE RESISTIVE OR SMOKE CONTROL CONSTRUCTION. CONTRACTOR SHALL SEAL PENETRATIONS SMOKE TIGHT. METAL TRIM OR ESCUTCHEONS ALONE SHALL NOT BE ACCEPTABLE. X HIGH SCHOOL ROOF DEMOLITION PLAN HIGH SCHOOL BUILDING DEMOLITION ELEVATIONS AND DEMOLITON SECTIONS HIGH SCHOOL ROOF PLAN HIGH SCHOOL BUILDING ELEVATIONS AND WALL SECTIONS S HARRIS ST CONTRACTOR(S) SHALL COOPERATE WITH THE OWNER IN THE SCHEDULING AND EXECUTION OF THE WORK AND USE OF THE SITE. S SCHOOL ST X CONTRACTOR'S OPERATIONS AND STORAGE OF MATERIALS SHALL BE CONFINED TO THE MINIMUM AREA(S) OF THE SITE NECESSARY TO ACCOMPLISH THE WORK. THE LOCATION OF THE AREA(S) SHALL BE APPROVED BY THE OWNER. W 7TH ST W 8TH ST DETAIL REFERENCE XX THE KEYNOTING SYSTEM IS USED ON THE DRAWINGS TO IDENTIFY CONSTRUCTION MATERIALS AND TO REFERENCE THEM TO THE TECHNICAL SPECIFICATIONS FOUND IN THE PROJECT MANUAL. REFER TO THE KEYNOTE LEGEND ON THE DRAWINGS FOR THE INFORMATION WHICH RELATES TO EACH KEYNOTE SYMBOL. ALL DRAWINGS MUST BE COORDINATED WITH THE PROJECT MANUAL. THE ORGANIZATION OF THE KEYNOTING SYSTEM ON THE DRAWINGS SHALL NOT CONTROL THE CONTRACTOR IN DIVIDING THE WORK AMONG THE SUBCONTRACTORS OR IN ESTABLISHING THE EXTENT OF WORK TO BE PERFORMED BY ANY TRADE. SCOPE OF WORK DESIGNATION IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. D PROJECT NAME X GRIDLINE X FRAME TYPE DOOR NUMBER XXX C S SHIMERDA ST E 06/05/2013 GENERAL DRAWINGS DO NOT SCALE DRAWINGS. G DESCRIPTION Vicinity Plan S FRANKLIN ST H DATE X REVISION KEYNOTE X LEGEND KEYNOTE PROJECT: F16127 DATE: 04/18/2016 © Copyright 2012 Bahr Vermeer Haecker Architects, LTD 4/18/2016 COORDINATING PROFESSIONAL COVER SHEET CLOUDED REVISION B MATERIAL MATERIAL ROOM NAME # I, CRAIG A. WOHLGEMUTH, CERTIFY THAT I AM THE COORDINATING PROFESSIONAL FOR THE: FLOOR MATERIAL WILBER-CLATONIA HIGH SCHOOL ROOF REPLACEMENT AND EXTERIOR RENOVAITON 4-18-2016 ROOM TAG G1.0 A ELEVATION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 V 16 17 18 AD1.2 1 19 20 21 22 GENERAL DEMOLITION NOTES 9 4 14 4 U A. VERIFY ITEMS TO BE SALVAGED OR TO REMAIN IN PLACE PRIOR TO ANY BUILDING DEMOLITION OPERATIONS. B. ALL EXISTING ITEMS NOT INDICATED TO BE REMOVED THAT ARE DAMAGED DURING DEMOLITION OR CONSTRUCTION SHALL BE REPAIRED TO ORIGINAL CONDITION AT NO ADDITIONAL COST TO THE OWNER 4 4 6 6 10 9 13 4 10 6 12 ARCHITECT 9 BAHR VERMEER HAECKER ARCHITECTS C. T 24 A1 A1.2 H1 9 23 12 12 DASHED LINES INDCATE ITEMS TO BE REMOVED. PATCH ADJACENT SURFACE TO MATCH EXISTING SURFACES. 440 N 8TH ST STE 100 LINCOLN NE 68508 V 402 475 4551 D. 12 4 4 A19 A1.2 VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS IN THE FIELD. ANY DISCREPANCY BETWEEN EXISTING CONDITIONS AND THOSE SHOWN ON THE DRAWINGS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. F 402 475 0226 bvh.com A10 AD1.2 10 6 7 4 14 ROOF DEMOLITION PLAN NOTES 12 6 R S1 8 AD1.2 9 S 4 3 AD1.2 1 REMOVE EXISTING METAL CAP FLASHING IN ITS ENTIETY. 2 REMOVE EXISTING FULLY ADHERED EPDM ROO MEMBRANE AND RIGID INSULATION. 3 REMOVE EXISTING METAL ROOF EDGE FLASHING IN ITS ENTIRETY. 4 EXISTING PLUMBING VENT TO REMAIN. PROTECT DURING ALL PHASES OF CONSTRUCTION. 5 EXISTING TRANSLUCENT SKYLIGHT TO REMAIN. PROTECT DURING ALL PHASE OF CONSTRUCTION. 6 EXISTING HVAC HOOD TO REMAIN. PROTECT DURING ALL PHASES OF CONSTRUCTION. 7 EXISTING FULLY ADHERED EPDM ROOF MEMBRANE TO REMAIN. PROTECT DURING ALL PHASES OF CONSTRUCTION. 8 EXISTING METAL CAP FLASHING TO REMAIN. PROTECT DURING ALL PHASES OF CONSTRUCTION. 9 EXISTING ROOF DRAIN TO REMAIN. 4 4 E1 1 12 9 9 9 P 9 9 9 2 N 9 F1 C1 AD1.2 A1 8 AD1.2 6 1 9 A1.2 6 4 A14 A1.2 4 2 3 10 20 3 12 6 M 12 F10 AD1.2 2 6 10 EXISTING ROOF TOP HVAC UNIT TO REMAIN. PROTECT DURING ALL PHASES OF CONSTRUCTION. 11 EXISTING ROOF HATCH TO REMAIN. 12 REMOVE EXISTING ABANDONED ROOF TOP CURB IN IT'S ENTIRETY AND INFILL HOLE IN EXISTING METAL ROOF DECK WITH NEW METAL ROOF DECK. 13 EXISTING ROOF TOP EXHAUST FAN AND DUCT FOR FUME HOOD TO BE TEMPORARILY REMOVED FOR INSTALLATION OF NEW EPDM ROOF MEMBRANE AND INSULATION. PROTECT DURING ALL PHASES OF CONSTRUCTION. 14 EXISTING CONDENSING UNIT TO BE TEMPORARILY REMOVED FOR INSTALLATION OF NEW EPDM ROOF MEMBRANDE AND INSUALTION. ELECTRICAL POWER SUPPLY AND REFRIGERANT LINES TO BE REROUTED THROUGHT THE NEW ROOF MEMBRANE AND NOT OVER AND THROUGH THE EXTERIOR WALL. 15 EXISTING SURFACE MOUNTED ELECTRICAL COUNDUIT FOR EXTERIOR LIGHTING TO REMAIN IN PLACE. PROTECT DURING ALL PHASES OF CONSTRUCTION. 16 EXISTING ANTENNA TO BE RELOCATED BY OWNER PRIOR TO CONSTRUCTION. 17 EXISTING PITCH POCKET FOR ANTENNA TO BE REMOVED AND HOLE IN METAL ROOF DECK TO BE PATCHED. 12 6 2 10 9 A5 A1.1 A13 A1.1 4 9 6 9 9 9 L 9 1 8 6 4 6 12 9 4 8 9 19 6 G1 H1 20 12 3 20 AD1.2 A1.2 K 4 1 19 7 4 F19 A1.2 18 6 6 6 REVISIONS SCHEDULE 10 21 J 4 5 6 12 15 21 12 12 4 10 9 9 8 EXISTING ANTENNA CABLE FO ITEM #16 TO BE RELOCATED BY THE OWNER PRIOR TO CONSTRUCTION. 19 EXISTING ANTENNA WIRE FOR ANTENNA LOCATED ON EAST EXTERIOR WALL TO BE RELOCATED BY THE OWNER PRIOR TO CONSTRUCTION. 20 EXISTING CABLE TV WIRE TO BE RELOCATED BY OWNER PRIOR TO CONSTUCTION. 21 EXISTING ABANDONED HVAC SUPPORTS AND PIPING TO BE REMOVED AND HOLES IN METAL ROOF DECK TO BE PATCHED. 15 4 H 18 16 4 17 11 MARK DATE DESCRIPTION 6 6 G 4 8 7 K1 4 F 7 F16 AD1.2 7 AD1.2 A1.2 8 7 PROJECT NAME E PROJECT: F16127 DATE: 04/18/2016 © Copyright 2012 Bahr Vermeer Haecker Architects, LTD D 7 C 4/18/2016 HIGH SCHOOL ROOF DEMOLITION PLAN B Project North A A1 1 AD1.1 03 - HIGH SCHOOL ROOF DEOMOLITION PLAN 3/32" = 1'-0" 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 V 3 U 4 1 8 F10 AD1.2 2 1 A10 G9 AD1.2 A1.2 6 2 ARCHITECT BAHR VERMEER HAECKER ARCHITECTS 440 N 8TH ST STE 100 T LINCOLN NE 68508 5 V 402 475 4551 F 402 475 0226 bvh.com 5 S S1 NORTH DEMOLITION ELEVATION - HIGH SCHOOL 1/8" = 1'-0" R 3 5 4 1 2 1 A1 A1.2 6 2 P 5 N 6 M H1 6 WEST DEMOLITION ELEVATION - HIGH SCHOOL 1/8" = 1'-0" F16 F14 AD1.2 A1.2 1 8 2 GENERAL DEMOLITION NOTES 1 REMOVE EXISTING WOOD BLOCKING 9 L REMOVE EXISTING EPDM ROOF MEMBRANE AND ROOF INSULATION REMOVE EXISTING EPDM ROOF MEMBRANE AND ROOF INSULATION A. VERIFY ITEMS TO BE SALVAGED OR TO REMAIN IN PLACE PRIOR TO ANY BUILDING DEMOLITION OPERATIONS. B. ALL EXISTING ITEMS NOT INDICATED TO BE REMOVED THAT ARE DAMAGED DURING DEMOLITION OR CONSTRUCTION SHALL BE REPAIRED TO ORIGINAL CONDITION AT NO ADDITIONAL COST TO THE OWNER C. DASHED LINES INDCATE ITEMS TO BE REMOVED. PATCH ADJACENT SURFACE TO MATCH EXISTING SURFACES. D. VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS IN THE FIELD. ANY DISCREPANCY BETWEEN EXISTING CONDITIONS AND THOSE SHOWN ON THE DRAWINGS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. 3 2 EXISTING STEEL ROOF DECK EXISTING STEEL ROOF JOISTS K K1 EAST DEMOLITION ELEVATION - HIGH SCHOOL EXISTING STEEL STRUCTURE 1/8" = 1'-0" 4 EXISTING VERTICAL STEEL ANGLES TO REMAIN 3 J 7 EXISTING STEEL ROOF JOIST EXISTING METAL ROOF DECK EXISTING CMU WALL 7 4 EXISTING EPDM MEMBRANE FLASHING TO REMAIN 4 REMOVE EXISTING WOOD BLOCKING EXISTING VERTICAL STEEL ANGLES TO REMAIN MARK G1 DATE DESCRIPTION BUILDING DEMOLITION ELEVATION NOTES EXISTING TAPERED INSULATION AND EPDM ROOF MEMBRANE TO REMAIN REMOVE EXISTING EPDM ROOF MEMBRANE AND ROOF INSULATION H REVISIONS SCHEDULE EAST CLERESTORY DEMOLITION ELEVATION 1 REMOVE EXISTING METAL CAP FLASHING IN ITS ENTIETY. 2 REMOVE EXISTING METAL WALL PANEL AND ALL ASSOCIATED METAL FRAMING IN ITS ENTIRETY. 3 REMOVE EXISTING METAL ROOF EDGE FLASHING IN ITS ENTIRETY. 4 REMOVE EXISTING INSULATED METAL WALL PANEL IN ITS ENTIRETY. 5 PROTECT EXISTING BRICK VENEER DURING ALL PHASE OF CONSTRUCTION. 6 PROTECT EXISTING ALUMINUM STOREFRONT FRAMING DURING ALL PHASES OF CONSTRUCTION. 7 EXISTING LAMBS TONGUE TO REMAIN IN PLACE. 8 PROTECT EXISTING EXTERIOR INSULATION FINISH SYSTEM DURING ALL PHASES OF CONSTRUCTION. 1/8" = 1'-0" 3 G 7 EXISTING STEEL ROOF DECK 7 4 EXISTING STEEL ROOF JOISTS EXISTING STEEL STRUCTURE F10 DETAIL - CLERESTORY WALL - DEMOLITIOIN F16 1" = 1'-0" DETAIL - EXTERIOR WALL - EAST DEMOLITION 1" = 1'-0" F E1 REMOVE EXISTING EPDM ROOF MEMBRANE AND ROOF INSULATION WEST CLERESTORY DEMOLITION ELEVATION PROJECT NAME 1/8" = 1'-0" 1 E 3 F10 AD1.2 PROJECT: F16127 4 DATE: 04/18/2016 © Copyright 2012 Bahr Vermeer Haecker Architects, LTD 2 D C C1 NORTH CLERESTORY DEMOLITION ELEVATION EXISTING STEEL ROOF JOIST 1/8" = 1'-0" 4/18/2016 EXISTING METAL ROOF DECK 3 HIGH SCHOOL BUILDING DEMOLITION ELEVATIONS AND DEMOLITON SECTIONS 4 EXISTING BRICK VENEER B EXISTING CMU WALL A A1 1 SOUTH CLERESTORY DEMOLITIONO ELEVATION A10 1/8" = 1'-0" 2 3 4 5 6 7 8 9 10 AD1.2 DETAIL - EXTERIOR WALL - TYPICAL DEMOLITION 1" = 1'-0" 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A1.2 1 3 V 17 G9 Sim A1.2 18 19 20 21 22 23 24 A1 A1.2 N1 9 9 4 4 A1 Sim A1.2 U 4 14 4 12 12 ST R SL UC OP T ES T UC R ST PES O SL 10 ST R SL UC OP T ES 10 ROOF PLAN NOTES CT RU ES T S OP SL 13 6 ST R SL UC OP T ES 9 STRUCT SLOPES 12 4 9 STRUCT SLOPES 12 S G9 A1.2 10 12 7 14 STRUCT SLOPES R STRUCT SLOPES 4 STRUCT SLOPES 6 6 4 A1.2 1 STRUCT SLOPES 4 H1Sim 9 9 075300 EPDM MEMBRANE ROOFING 9 9 9 3 ST R SL UC OP T ES A1.2 9 T UC R ST PES O SL 4 EXISTING PLUMBING VENT. PROVIDE PREFABRICATED EPDM PIPE FLASHING. 6 EXISTING TRANSLUCENT SKYLIGHT. PROTECT DURING ALL PHASES OF CONSTRUCTION. 6 EXISTING HVAC HOOD. TEMPORATILY REMOVE, INSTALL EPDM MEMBRANE FLASHING, AND REINSTALL EXISTING HVAC HOOD. 7 EXISTING FULLY ADHERED EPDM ROOF MEMBRANE. PROTECT DURING ALL PHASE OF CONSTRUCTION. 8 EXISTING METAL CAP FLASHING TO REMAIN. 9 EXISTING ROOF DRAIN, SEE DETAIL ON THIS SHEET. 10 EXISTING ROOF TOP HVAC UNIT. PROTECT DURING ALL PHASES OF CONSTRUCTION. 11 EXISTING ROOF HATCH TO REMAIN. 12 075200 WALKWAY / PROTECTION PAD INDICATED BY CROSSHATCH. 13 EXISTING ROOF TOP EXHAUST FAN AND DUCT FOR FUME HOOD TO BE TEMPORARILY REMOVED FOR INSTALLATION OF NEW EPDM ROOF MEMBRANE AND INSULATION. PROTECT DURING ALL PHASES OF CONSTRUCTION. A14 A1.2 PES SLO UCT STR 19 9 14 EXISTING CONDENSING UNIT TO BE TEMPORARILY REMOVED FOR INSTALLATION OF NEW EPDM ROOF MEMBRANDE AND INSUALTION. ELECTRICAL POWER SUPPLY AND REFRIGERANT LINES TO BE REROUTED THROUGHT THE NEW ROOF MEMBRANE AND NOT OVER AND THROUGH THE EXTERIOR WALL. 15 EXISTING SURFACE MOUNTED ELECTRICAL COUNDUIT FOR EXTERIOR LIGHTING TO REMAIN IN PLACE. PROTECT DURING ALL PHASES OF CONSTRUCTION. 16 EXISTING ANTENNA TO BE RELOCATED BY OWNER PRIOR TO CONSTRUCTION AND REINSTALLED BY OWNER AFTER REROOF IS COMPLETE. 17 PROVIDE NEW ROOF PENETRATION FOR EXISTING ANTENNA WIRE. 18 EXISTING ELECTRICAL PENETRATION THROUGH ROOF TO REMAIN. PROVIDE NEW PREMANUFACTURED FLASHING. 19 EXISTING ELECTRICAL CONDUIT TO BE REINSTALLED ON BACKSIDE OF NEW CAP FLASHING. 12 10 ES OP T SL UC R ST 2 M A9 A1.2 SL O ST PES RU CT 12 6 6 9 A13 A1.1 1 ES OP T SL UC R ST 2 SL O ST PES RU CT 10 4 9 6 6 9 9 F 402 475 0226 bvh.com 6 9 4 6 9 9 1 12 3 A5 A1.1 19 A13 Sim A1.1 L 2 3 ES OP CT L S RU ST 6 3 4 A1.2 1 A1.2 S1 N LINCOLN NE 68508 5 4 F1 F1Sim 8 440 N 8TH ST STE 100 076200 ROOF EDGE FLASHING 2 A19 Sim A1.2 ARCHITECT 3 9 19 P 4 STRUCT SLOPES 2 V 402 475 4551 12 8 076200 CAP FLASHING BAHR VERMEER HAECKER ARCHITECTS CT RU ES T S OP SL 4 A19 A1.2 1 4 9 T 6 4 1 9 19 6 A1 Sim A1.2 G1 H1 1 AD1.2 A1.2 6 K STRUCT SLOPES 4 STRUCT SLOPES 3 STRUCT SLOPES 7 4 6 F19 A1.2 6 10 REVISIONS SCHEDULE J 4 18 MARK 6 5 15 17 6 STRUCT SLOPES 4 H DESCRIPTION 15 4 12 DATE STRUCT SLOPES 9 8 4 10 16 12 11 9 STRUCT SLOPES 6 6 G 4 8 7 4 K1 3 7 F14 A1.2 7 AD1.2 A1.2 F 8 7 PROJECT NAME E PROJECT: F16127 DATE: 04/18/2016 © Copyright 2012 Bahr Vermeer Haecker Architects, LTD D 03 - HIGH SCHOOL ROOF PLAN 3/32" = 1'-0" 076200 CAP FLASHING 2'-0" 075300 MEMBRANE FLASHING 061000 WOOD BLOCKING 061000 WOOD BLOCKING 075300 TAPERED BD INSULATION 075300 EPDM MEMBRANE ROOFING 075300 COVER BOARD 075300 EPDM MEMBRANE ROOFING 075300 FIELD FABIRCATED EXPANSION JOIJST 061000 WOOD BLOCKING 075300 TAPERED BD INSULATION 075300 EPDM MEMBRANE ROOFING 075300 COVER BOARD 4'-0" TYP EXISTING EPDM MEMBRANE ROOFING 075300 TAPERED BD INSULATION 075300 COVER BOARD 4" EXISTING ROOF DRAIN ? ? ? PREFORMED INSULATION SUMP - 1":FT SLOPE MIN 075300 BOARD INSULATION 5 1/2" C L C ROOF PLAN LEGEND EXISTING ELECTRICAL CONDUIT REINSTALLED IN PREVIOUS LOCATION 075300 MEMBRANE FLASHING 4'-0" TYP 075300 FIELD FABIRCATED EXPANSION JOIJST 4" 075300 MEMBRANE FLASHING 3" 1" C1 075300 BOARD INSULATION MEMBRANE ROOFING W/ TAPERED INSULATION OVER BASE INSULATION - 1/4":FT MIN POSITIVE SLOPE 075300 BOARD INSULATION 075300 BOARD INSULATION STRCT SLOPES X":FT B 1" ROOF EXPANSION JOINT EXISTING STEEL JOIST EXISTING STEEL BEAM EXISTING STEEL JOIST EXISTING STEEL JOIST 1" EXISTING STEEL JOIST EXISTING STEEL ROOF DECK EXISTING STEEL BEAM EXISTING CMU WALL EXISTING CMU WALL EXISTING ROOF DRAIN PIPING GENERAL NOTES: EXISTING STEEL ROOF DECK PROVIDE 8" MIN CLEARANCE AT ALL CURBS, PARAPETS, AND FLASHINGS ABOVE THE ROOF TO WALL TRANSITION UNO. A A1 1 DETAIL - EXISTING ROOF DRAIN 1 1/2" = 1'-0" 2 3 4 A5 5 MEMBRANE ROOFING W/ BASE INSULATION - 1/4":FT MIN POSITIVE SLOPE HIGH SCHOOL ROOF PLAN EXISTING STEEL ROOF DECK EXISTING STEEL ROOF DECK VAPOR RETARDER, SEAL TO DECK EXISTING STEEL ROOF DECK 4/18/2016 ROOF DRAIN W/ BOARD INSULATION SUMP DETAIL - ROOF EXPANSIOIN JOINT A13 1" = 1'-0" 6 7 8 9 10 11 12 13 Project North A1.1 PROVIDE CRICKETS AT ALL ROOF PENETRATIONS. DETAIL - EXPANSION JOINT AT PARAPET 1" = 1'-0" 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 V A9 A1.2 EXISTING EIFS, PRTOECT DURING CONSTRUCTION 076200 ROOF EDGE FLASHING 072400 EIFS G9 A1.2 072400 EIFS 076200 ROOF EDGE FLASHING U 072400 EIFS EXISTING BRICK VENEER, PRTOECT DURING CONSTRUCTION ARCHITECT BAHR VERMEER HAECKER ARCHITECTS 440 N 8TH ST STE 100 T LINCOLN NE 68508 V 402 475 4551 EXISTING BRICK VENEER, PRTOECT DURING CONSTRUCTION S1 EXISTING ALUMINUM STOREFRONT FRAMING, PRTOECT DURING CONSTRUCTION NORTH ELEVATION - HIGH SCHOOL F 402 475 0226 bvh.com 1/8" = 1'-0" S EXISTING BRICK VENEER, PRTOECT DURING CONSTRUCTION 076200 ROOF EDGE FLASHING 072400 EIFS 076200 CAP FLASHING R A1 A1.2 076200 ROOF EDGE FLASHING 072400 EIFS 072400 EIFS EXISTING BRICK VENEER, PRTOECT DURING CONSTRUCTION P EXISTING ALUMINUM STOREFRONT FRAMING, PRTOECT DURING CONSTRUCTION WEST ELEVATION - HIGH SCHOOL 1/8" = 1'-0" 061000 5/8" PLYWOOD SUBSTRATE 061000 WOOD BLOCKING 076200 ROOF EDGE FLASHING F14 A1.2 075300 EPDM MEMBRANE ROOFING 075300 COVER BOARD 075300 TAPERED BD INSULATION 061000 WOOD BLOCKING 075300 BOARD INSULATION 1'-1 1/8" 061000 WOOD BLOCKING 076200 ROOF EDGE FLASHING 4 3/4" 3 3/4" 072400 EIFS 075300 MEMBRANE FLASHING EXISTING EPDM MEMBRANE FLASHING M L EAST ELEVATION - HIGH SCHOOL 072400 EIFS 1/8" = 1'-0" 072400 AIR BARRIER 7" K1 1'-1 1/8" 061000 WOOD BLOCKING 076200 ROOF EDGE FLASHING 3 3/4" N1 EXISTING ALUMINUM STOREFRONT FRAMING, PRTOECT DURING CONSTRUCTION 4 3/4" N EXISTING ALUMINUM STOREFRONT FRAMING, PRTOECT DURING CONSTRUCTION 061000 5/8" PLYWOOD SUBSTRATE 061000 WOOD BLOCKING 075300 EPDM MEMBRANE ROOFING 075300 COVER BOARD 075300 TAPERED BD INSULATION 061000 WOOD BLOCKING 075300 BOARD INSULATION 092116 GLASS MAT FACED SHEATHING 092116 2-1/2" STUD FURRING 076200 ROOF EDGE FLASHING 072100 BATT INSULATION EXISTING BRICK VENEER 079005 SEALANT/BACKER ROD 052100 STEEL JOIST 092116 2-1/2" STUD FURRING 053100 STEEL DECKING 076200 COUNTER FLASHING 075300 TERM BAR/SEALANT 075300 MEMBRANE FLASHING 075300 FIELD FABIRCATED EXPANSION JOIJST 061000 WOOD BLOCKING 075300 TAPERED BD INSULATION 075300 EPDM MEMBRANE ROOFING 075300 COVER BOARD 075300 BOARD INSULATION J H1 EAST CLERESTORY ELEVATION 076200 FLASHING EXISTING BRICK VENEER 1/8" = 1'-0" NOTE: WEST CLERESTORY WALL SIIMILAR H G9 072400 EIFS 1" 1" = 1'-0" 1/8" = 1'-0" NOTE: SOUTH CLERESTORY WALL SIIMILAR 8 1/8" 7" NORTH CLERESTORY ELEVATION EXISTING STEEL JOIST EXISTING STEEL ROOF DECK EXISTING STEEL BEAM EXISTING CMU WALL 061000 5/8" PLYWOOD SUBSTRATE 061000 WOOD BLOCKING 076200 ROOF EDGE FLASHING 4 3/4" 075300 MEMBRANE FLASHING 075300 EPDM MEMBRANE ROOFING 075300 COVER BOARD 075300 TAPERED BD INSULATION 061000 WOOD BLOCKING 075300 BOARD INSULATION 4". 075300 MEMBRANE FLASHING DESCRIPTION DETAIL - EXTERIOR WALL - EIFS 061000 5/8" PLYWOOD SUBSTRATE 061000 WOOD BLOCKING 075300 MEMBRANE FLASHING G DATE EXISTING TAPERED INSULATION AND EPDM ROOF MEMBRANE TO REMAIN 076200 ROOF EDGE FLASHING A9 A1.2 MARK EXISTING EPDM MEMBRANE FLASHING TO REMAIN EXISTING CMU WALL F1 EXISTING STEEL ROOF JOIST EXISTING METAL ROOF DECK EXISTING CMU WALL REVISIONS SCHEDULE 2'-8" 072400 EIFS 072400 AIR BARRIER 3" 075300 MEMBRANE FLASHING 5" EXISTING LAMBS TONGUE 3'-10 3/4" F.V. K F14 TOP OF BEAM 19'-4" 1" EXISTING METAL ROOF DECK EXISTING STEEL ROOF JOIST EXISTING EXTERIOR METAL STUD WALL EXISTING STEEL BEAM EXISTING STEEL ANGLE STRUCTURAL FRAMING 092116 SUSPENDED CEILING FRAMING 092116 7/8" HAT FURRING 072100 BATT INSULATION 072100 VAPOR RETARDER 3" 054000 6" STRCT STUD FRAMING 2'-0" EXISTING STEEL COLUMN BEYOND 054000 6" STRCT STUD FRAMING EXISTING CURVED BRICK VENEER BEYOND 3" PROJECT: F16127 DATE: 04/18/2016 © Copyright 2012 Bahr Vermeer Haecker Architects, LTD 061000 WOOD BLOCKING HEMMED DRIP EDGE 075300 MEMBRANE FLASHING 075300 EPDM MEMBRANE ROOFING 061000 WOOD BLOCKING 075300 COVER BOARD 075300 BOARD INSULATION 075300 TAPERED BD INSULATION 075300 EPDM MEMBRANE ROOFING 075300 COVER BOARD 075300 BOARD INSULATION 4/18/2016 EXISTING BRICK VENEER EXISTING METAL ROOF DECK EXISTING STEEL ROOF JOIST EXISTING CMU WALL TOP OF BEAM 12'-8" 11'-0" F.V. 076200 COUNTER FLASHING 075300 TERM BAR/SEALANT 075300 MEMBRANE FLASHING 061000 WOOD BLOCKING 4" EXTEND COUNTER FLASHING AND MEMBRANE FLASHING BEHIND EIFS 076200 COUNTER FLASHING 075300 MEMBRANE FLASHING 075300 EPDM MEMBRANE ROOFING 075300 COVER BOARD 075300 TAPERED BD INSULATION 075300 BOARD INSULATION 4" EXISTING 1-1/2"X1-1/2"1/4" STEEL ANGLE, VERTICAL, AT 4'-0" O.C. EXISTING CURVED BRICK VENEER BEYOND HIGH SCHOOL BUILDING ELEVATIONS AND WALL SECTIONS EXISTING STEEL JOIST EXISTING STEEL ROOF DECK EXISTING CMU WALL EXISTING STEEL STRUCTURE EXISTING CONC. COLUMN BEYOND 092116 GLASS MAT FACED SHEATHING 072400 AIR BARRIER 072400 EIFS SOFFIT SYSTEM 061000 WOOD BLOCKING EXISTING STEEL ROOF DECK EXISTING STEEL ROOF JOISTS DETAIL - EXTERIOR SOFFIT A9 1" = 1'-0" 2 076200 CAP FLASHING EXTEND AIR BARRIER FLASHING OVER COUNTER FLASHING 072100 BATT INSULATION 1 061000 WOOD BLOCKING 061000 5/8" PLYWOOD SUBSTRATE 8" 6" 072400 AIR BARRIER 092116 GLASS MAT FACED SHEATHING 054000 2-1/2" STRCT STUD FRAMING A1 EXISTING BRICK VENEER 079005 SEALANT/BACKER ROD 072400 EIFS 072400 AIR BARRIER 092116 GLASS MAT FACED SHEATHING D 054000 METAL STUD FRAMING CLIP 1" = 1'-0" 5" 072400 EIFS A 1" = 1'-0" DETAIL - ROOF EXPANSION JOINT AT GYM PROJECT NAME 072400 EIFS 072400 AIR BARRIER 092116 GLASS MAT FACED SHEATHING 054000 6" STRCT STUD FRAMING 072100 BATT INSULATION EXISTING STEEL ROOF JOISTS EXISTING STEEL ROOF DECK EXISTING STEEL STRUCTURE C F19 054000 METAL STUD FRAMING CLIP, DIETRICH 8" FASTCLIP (FCEC) 12GA, AT EVERY STRUCTURAL STUD EXISTING WOOD BLOCKING 054000 METAL STUD FRAMING CLIP B DETAIL - EXTERIOR WALL - EAST 2'-4" 7" E 061000 5/8" PLYWOOD SUBSTRATE 061000 WOOD BLOCKING 075300 EPDM MEMBRANE ROOFING 075300 COVER BOARD 075300 TAPERED BD INSULATION 061000 WOOD BLOCKING 075300 BOARD INSULATION 4" 1" 1'-1 1/2" 3 3/4" 061000 WOOD BLOCKING 076200 ROOF EDGE FLASHING 1'-0" F 3 4 5 6 7 8 9 Project North DETAIL - CLERESTORY WALL A14 1" = 1'-0" 10 11 12 13 14 DETAIL - EXTERIOR WALL BRICK VENEER A19 1" = 1'-0" 15 16 17 18 19 A1.2 DETAIL - EXTERIOR WALL AT AUDITORIUM 1" = 1'-0" 20 21 22 23 24