Home Pump Leaflet_F - Ebara Pumps Malaysia

Transcription

Home Pump Leaflet_F - Ebara Pumps Malaysia
EBARA Quality
y Home Pump Range
ty
y Du
Heav Pump
p
m
u
S
*
n
*
Au
t
n
D r y - Ru
o
ion
Protect
LLER
NTRO
PC CO
Silent
o
Op
e ra ti
A
EBARA
nverter
with Inve
Model
Mode
M
ode
dell : AM6-PC
AM6-PC
AM
AM6
C
0.4kW
04 W
Model
del : DWVG
WVG
VG
G
Model
M
: JET - E(P1)
APPLICATION
Car Wash
Shower
Fountain
Gardening
Koi Pond
Your Reliable Pump Solution Provider :
Ebara HQ and factory in UEP
E Subang
Suban
Suban
Su
bang
g Jaya,
JJaya
aya,
y , Selangor
EBARA Pumps Malaysia Sdn Bhd
E
6, Jalan TP3, UEP Subang Jaya Industrial Park,
47
47620 Subang Jaya, Selangor, Malaysia.
Te
Tel
el : 03-8023 6622 Fax : 03-8023 9355
E
Email
mail : sales@ebara.com.my
Website : www.ebara.com.my
W
ww
www.e
w. bara.com.my
PUMP
for Water Boosting / Shower
Booster Unit
QUALITY Automatic B
- Ru
ction
D ry
Au t
n
o
Type COMPACT
COMPA
BOOSTER AM - PC
n
*
Prote
ER
OLL
NTR
O
C
PC
t
Silen
*
Op atio
er
Model
M
Mod
el : AM6-PC
A
0.4kW
0
OPERATIVE FEATURES COMPACT BOOSTER type AM-PC
‡ Quiet operation, thanks to EBARA design that makes this possible
‡ Starts and stops the pump when the tap is opened or closed
‡ Maintain pressure at a constant level during operation, eliminating hot/cold shower fluctuations
‡ Shuts off the pump if loss of prime or dry-running occurs
‡ Ensure your pump system to operate at optimum performance
PC CONTROLLER
PRESSCONTROL (PC) is an electronic device ensuring optimum control of
automatic water pressure system.
An intelligent combination of hydraulic and electronic know-how, PC controller
monitors both pressure and flow and automatically controls the pump efficiently. No
pressure tank required and no adjustment of pressure setting is required. Also, any
risk of pump damage as a result of dry running is eliminated, as the device will
automatically cut-off should the incoming water supply is insufficient.
Much more compact than traditional system, EBARA COMPACT BOOSTER type
AM-PC is absolutely quiet, durable and simple to install.
kW
Compact Booster
AM 6-PC
0.4
Compact Booster
AM 8-PC
0.6
*Application
/min
m3/h
Head in m
MODEL
20
1.2
30
1.8
40
2.4
50
3
60
3.6
80
4.8
Connection
30.7
28.2
25.2
21.8
18
9
1” x 1”
39.7
36.1
32
27.4
22.4
10.5
1” x 1”
*For guidance only
PUMP
for Water Boosting / Shower
QUALITY Automatic Booster Unit
Type COMPACT BOOSTER AM - PT
FEATURES / BENEFITS
‡ Fully tested & assembled unit.
*Ensure trouble-free operation
‡ Stainless steel pump set used.
*Hygiene and corrosion-free water
ed
d.
‡ EBARA 1-year warranty on all components used.
*More value for money
‡ Quiet operation.
*Good and enjoyable pressure expected
‡ Nationwide Dealers representation.
*After sales service assurance
Model
M
Mod
od
odel
odel
el : AM6
AM6-PT
A
AM
M
M6
6-PT
0.4kW
4kW
kW
W
World renowned and Japan’s No.1 pump
pum
ump
p manufacturer
manufact
ctur
urer
e
EBARA proudly introduce EBARA Home Pump Series that gives you
peace of mind pumping operation with below application :
‡ Water boosting operation for shower ‡ Fountain
‡ Car wash & gardening ‡ Pools & ponds
‡ Other home applications
kW
Compact Booster
AM 6-PT
0.4
Compact Booster
AM 8-PT
0.6
*Application
/min
m3/h
Head in m
MODEL
20
1.2
30
1.8
40
2.4
50
3
60
3.6
80
4.8
Connection
30.7
28.2
25.2
21.8
18
9
1” x 1”
39.7
36.1
32
27.4
22.4
10.5
1” x 1”
*For guidance only
PUMP
for Water Boosting / Shower
QUALITY Automatic Variable
Sp
Speed Booster Unit
Type JET-E (P1)
EBARA
EBA
A
Inve
nve
with Inverter
IN
INVERTER
Booster Pump System
with LCD Display PID Controller
w
Jet -E
E (P1)
(P1)
FEATURES / BENEFITS
Constant pressure
* PID Controller with inverter able to adjust water
pressure perfectly by variable speed control.
Energy saving
* Using of the inverter able to save energy.
No water hammering
* Preventing water hammer as speed is adjusted
automatically to meet variable demand.
Fully tested & assembled unit
* Ensure trouble-free operation.
Stainless steel pump set used
* Hygienic and clean water assured.
EBARA TOTAL warranty on all
components used
PID
D Co
Controller
Contr
ntroll
oller
ller Fun
F
Functi
Function
uncti
ction
on wi
w
wit
with
ith iinve
inverter,
nverte
nve
rterr,
rte
r,
* More value for money.
thus
thu
th
se
enable
nabl
nab
ble
le var
v
vari
variable
ariab
i ble
iabl
le spe
speed
ed and
booster pump control that provides
Nationwide dealers representation
optimal energy saving and comfort
* After sales service assurance.
pressure boosting operations.
PERFORMANCE TABLE
Pump type
Single-phase
230V 50Hz
JET 70/07 (P1)
JET 90/10 (P1)
JET 120/12 (P1)
Power
kW
0.55
0.75
0.9
HP
0.8
1
1.2
I/min
m 3 /h
20
1.2
50
3
Q = Capacity
80
90
110
4.8
5.4
6.6
130
7.8
160
9.6
28
30.3
-
24.5
27.2
29.5
20.5
23.6
27.1
22.4
19.5
H=Total head
22.3
26.1
19.5
24.3
PUMP
for Pools & Ponds
QUALITY Stainless Steel
Submersible Pumps
in AISI 304
Type BEST 2-3-4-5
FEATURES / BENEFITS
‡ Asynchronous 2 poles motor
‡ Insulation class : F
‡ Protection degree : IP68
‡ 1~230V ± 10%, 50Hz - 3~400V ± 10%, 50Hz
‡ Solid passage of 10mm
‡ Permanent split capacitor and automatic thermal overload protection for
‡
‡
single-phase version
Thermal protection to be provided by the user for three phase-version
DNM 11/2"
PERFORMANCE TABLE
Pump type
Single-phase
Three-phase
230V 50Hz
400V 50Hz
kW
BEST 2 M
BEST 3 M
BEST 4 M
-
0.55
0.75
1.1
1 .5
BEST 2
BEST 3
BEST 4
BEST 5
Capacitor
Absorbed Current (A)
μF
Vc
1~
3~
16
20
30
-
450
450
450
-
4.4
5.6
7.3
-
2.0
2.4
3.0
3 .3
I/min 20
m 3 /h 1.2
80
4.8
Q = Capacity
120 170 260 280 330 360
7.2 10.2 15.6 16.8 19.8 21.6
H=Total head
12.2 9.8 8.3 6.3 2.9
13.6 11.1 9.5 7.6
4
17.4 15 13.4 11.3 7.5
1 8 .4 1 6 .1 1 4 .5 1 2 .5 9
3.2
6.7
8
4.6
6
5
PUMP
for Small Pools & Ponds
QUALITY Submersible Sump
Pump
t
t
t
t
t
Type OPTIMA
Dewatering usage
Draining garages
Gardens and vegetable gardens irrigation
Emptying of basements
Easy emptying of tanks
FEATURES / BENEFITS
t
t
t
t
t
t
Asynchronous 2 poles motor
Insulation class : F
Protection degree : IP68
Permits 10mm solid passage
Permanent split capacitors and automatic thermal overload protection for single-phase version
DNM 11/4"
ELECTRICAL DATA
Capacitor
Single Phase
Pumps Type
Single Phase
Three Phase
OPTIMA M
OPTIMA
kW
0.25
HP
0.33
Input
[kW]
Full load current
[A]
Locked rotor
current [A]
μF
VI
Single Three Single Three
Single Three
Phase Phase Phase Phase
Phase Phase
230 V 400 V 230 V 400 V
8
450
0.45
0.45
1.90
0.95
4.8
3.2
Weight
(kg)
4.1
PUMP
for Koi Ponds & Fountains
QUALITY Submersible Pumps
(special design for fish pond)
Type DWVG
d
Compact, Light weight
AN
JAP
Easy installation and service
Tough and robust design
Anti-rust, Anti-corrosion materials used
Allow solid passage of 35mm ø
FEATURES / BENEFITS
t
Robust & Tough
t
Anti-rust
t
Large Solid Passage
t
Easy Installation
High performance engineering resin being used for pump casing and impeller; thus
enhance long operating life of pump.
As anti-rusting materials are used in contact with liquid, thus ensure easy
maintenance.
Utilize semi-vortex type of impeller permit max. 35mm ø solid passage; therefore
enhance passage capabilities.
50mm companion flange supplied as standard, for easy installation.
Model
Output
kW
Phase
50DWVG5.4S
0.4
Single
Frequency
Hz
DA A
50
Pump and Motor Dimensions
B
C
D
E
F
H DE L1 L2
50 226 156 148 78 110 92 365 96 113 265
Mass
Kg
8.0
PUMP
for Koi Ponds / Fountains / Pools & Ponds
QUALITY Stainless Steel
Submersible Pumps
(Sing channel impeller that permits 50mm
(Single
solid passage)
Type DW
t General submersible pumping
t Handling drain water and sewage for
t
t
t
communities, hotels, restaurants, etc.
Supplied with 10m cable length type H07RNF
Available with or without float switch
Single channel impeller or vortex impeller
(VOX type)
FEATURES / BENEFITS
t
t
t
t
t
t
t
t
Asynchronous 2 poles motor
Insulation class : F
Protection degree : IP68
1~230V ± 10% 50Hz, 3~400V ± 10% 50Hz
Permanent split capacitors and automatic thermal overload protection for single-phase version
Thermal protection to be provided by the user for three phase-version
DNA 50-DNM 2"
DNM 50PN10 (F version)
PERFORMANCE TABLE
Pump type
Single-phase
230V 50Hz
Three-phase
400V 50Hz
DW 75 M
DW 100 M
DW 150 M
-
DW 75
DW 100
DW 150
D W 200
D W 300
kW Capacitor Absorbed Current (A)
0.55
0.75
1.1
1 .5
2 .2
μF
Vc
1~
3~
400V
20
25
31.5
-
450
450
450
-
3.9
5.9
7.3
-
1.5
2.1
2.8
3 .6
5 .0
Q = Capacity
I/min 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 6 0 0 7 0 0 8 0 0 9 0 0
12 18 24 30 36 42 48 54
m 3 /h 6
H=Total head
8
6.3
10.6 8.7
13.1 11.3
1 6 .6 1 5
2 0 1 8 .3
4.8
3.4 2.2
7.1
5.5
4
2.6
9.5
7.7
5.9 4.2
1 3 .3 1 1 .4 9 .5 7 .5
1 6 .6 1 5 .1 1 3 .3 1 1 .3
2.4
5 .4
9 .3
3 .3
7 .2
5
-