New! - Leslie`s Pool Supplies
Transcription
New! - Leslie`s Pool Supplies
Pump Motors for Swimming Pools, Spas & ! New Jetted Tubs 2 Bulletin 1081-1082 ver k Co c a B nside See I A Deeper Pool of Resources www.pool-motors.com Statement of Warranty Policy Warranty Period AllA.O.Smithmotorsarewarrantedagainstdefectsinmaterialsandworkmanshipforaperiodoftwelve(12)monthsfromthedateofinstallationortwenty-fourmonths (24)fromthedateofmanufacture,whichevercomesfirst. Limitation of Remedy Intheeventofabreachofthewarrantywithintheapplicablewarrantyperiod,A.O.Smithshallhavetheoptionof(1)repairingsuchmotor;(2)supplyinganidenticalor substantiallysimilarreplacementmotorFOB,A.O.Smith’sfactory;or(3)refundingorgivingcreditforthepurchasepriceofsuchmotor. Theremedysetforthaboveshallbethesoleandexclusiveremedyforthemotorsfailingwithintheapplicablewarrantyperiod.A.O.Smith,shallnotbeliableforanylost profits,lossofuse,oranyotherconsequential,specialorincidentaldamages. DISCLAIMER OF IMPLIED WARRANTIES EXCEPTASMAYBEREQUIREDUNDERAPPLICABLELAW,THELIMITEDWARRANTYSETFORTHABOVEISTHEEXCLUSIVEWARRANTYPROVIDEDWITHTHEMOTORS. ALLOTHERWARRANTIES,WHETHERWRITTENORVERBAL,EXPRESSEDORIMPLIED,INCLUDINGTHEIMPLIEDWARRANTIESOFMERCHANTABILITYANDFITNESSFORA PARTICULARPURPOSEAREEXPRESSLYDISCLAIMEDBYA.O.SMITH. Conditions of Warranty Thislimitedwarrantyshallbevoidandofnoeffectif: 1.Themotorhasbeensubjectedtoimproperhandling,storageorinstallation,orsubjecttoabuseorunauthorizedrepairs; 2.Themotorwasnotsuitablefortheapplicationoroperatedaboveitsratedload;or 3.Themotorwassubjecttowaterdamageincludingmotorbearingfailuresresultingfrompumpsealfailures. Authorized Location DefectivemotorswhichhavefailedduringtheapplicablewarrantyperiodmustbereturnedfreightprepaidtoanA.O.Smith’sauthorizeddistributor.Call800-672-6495. How to Read Date Codes on Motor Nameplates & Labels Introduction of a new standard date code was implemented in August of 2006 and is used on all A. O. Smith product. The first three characters represent the day of the year, the next two the year, and the last two the plant code. For example, 123064M, would mean the 123rd day of 2006 (12306) manufactured in A. O. Smith’s plant (4M). A. O. Smith Product (Original Date Code) Plantcode–Month–Year.Example:7B99.7isaplantcodedesignation,Bisthemonth (January is A, February is B, etc.)and99istheyear. Century® Product (Original Date Code) Yearcode–Month.Example:CD3.CDistheyear(see table below).3isthemonth(1-12). 1992 1993 1994 1995 BK BL BM BN 1996 1997 1998 1999 BP BR BS BT 2000 2001 2002 2003 BU BW BX BY 2004 2005 2006 2007 BZ CA CB CC 2008 2009 2010 CD CE CF Contents Centurion Motor Replacement Guide ......................................................................................2-3 Two Compartment Motor Replacement Guide ..........................................................................4 Guardian® Pool Motors .................................................................................................................5 Two Compartment – C-Face Pool Filter Motors .......................................................................6-8 Centurion – C-Face Pool and Spa Pump Motors ....................................................................9-11 Two Compartment – Square Flange Pool Filter Motors ......................................................12-13 Centurion – Pool and Spa Pump Motors Square Flange .....................................................14-15 Above Ground – Pool, Flex 48 & Spa Motors .......................................................................16-17 Sta-Rite Direct Replacement Spa Motor ....................................................................................17 Century® – Three-Phase Swimming Pool Pump Motors ...........................................................18 Century® – Pool Cleaner Motors ................................................................................................18 Century® – Purex Direct Replacement Motors ..........................................................................19 Centurion – Three Phase Square Flange Pool & Spa Motors ...................................................19 Century® – Pentair/Pac Fab Direct Replacement Motors ..........................................................20 Century® – Waterway Direct Replacement Motors ..................................................................20 Century® – Hayward Northstar Replacement Motors ..............................................................21 Century® – Hayward Tristar Replacement Motors ...................................................................21 Century® – Close-Coupled Pump Motors: Three Phase Dripproof Motors ......................................................................................22 Three Phase Dripproof Rigid Base Motors ....................................................................23 Three Phase Dripproof NEMA C-Face Motors ...............................................................23 Three Phase TEFC Rigid Base Motors ........................................................................24-26 Single Phase Dripproof Rigid Base Motors ...................................................................27 Century® Close-Coupled Pump Motors ......................................................................................27 Speed Engineered® Motors ...................................................................................................28-29 Commercial Pump Motor Cross Reference ................................................................................30 Notes Index.............................................................................................................................31-32 www.pool-motors.com Centurion Pool & Spa Square Flange & C-face Replacement Guide Name of Pump OEM or Brand Name Group Americana, American Eagle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A American Ultra-flow or Power Pump . . . . . . . . . . . . . . . . . . . . . . C Aqua Flo C-face . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Aqua Flo Dominator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A,B,C Arneson Pool Sweep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D Hayward Northstar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E Baker Hydro Hydron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Hayward Super Pump or Super Pump II . . . . . . . . . . . . . . . . . . . . A Hayward Max-Flo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A ITT Marlow Argonaut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Jacuzzi Bros . Bronze . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Jacuzzi Bros . Cygnet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Jacuzzi Bros . Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Jacuzzi Bros . Magnum (E-Plus® columns only) . . . . . . . . . . . . . . . A Letro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D Pac Fab Challenger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Pac Fab Hydro Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Pac Fab Pinnacle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Polaris Vac-Sweep PB4 Booster Pump . . . . . . . . . . . . . . . . . . . . . D Premier/Springwater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Purex / Hydrotech . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Purex Whisperflo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Sta-Rite Dura-Glas or Max-E-Glas . . . . . . . . . . . . . . . . . . . . . . . . . C Sta-Rite Dura-Glas II or Max-E-Glas II . . . . . . . . . . . . . . . . . . . . . . . C Speck Pumps, Models 90, 98, 423, 433, 21-80 . . . . . . . . . . . . . . A Wet Institute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Zodiac (Jandy) Stealth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A,C Two-speed and three-phase motors available for most applications . Contact your distributor or A . O . Smith Electrical Products Company for more details . Before using the Pool & Spa Motor Replacement Guide, you will need to know the horsepower (1), the service factor (2) of the original motor, and the name and/or the manufacturer of the pump on which the motor is used . The sample nameplate below shows the location of the horsepower and service factor . 1 CE7-28 2 Find your pump brand, listed in alphabetical order at the right . Read across from the pump name and find the group of Century® catalog motors that will mechanically fit . These groups are labeled “A” through “E” . The service factor for each horsepower is shown in these groups below . Match the manufacturer of the pump, the horsepower, and the service factor and you will have a suitable replacement motor . Group “A” C-face Threaded Shaft (56J) Group “C” Square Flange Group “E” Northstar Hayward Hp Centurion® e-Plus® standardefficiency energyefficient Alum. Alum. Voltage Cat.no. Cat.no. Centurion® standard e-Plus® service efficiency e nergyefficient Hp Factor Voltage Cat.no. Cat.no. Hp Factor 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230 230 230 230 1⁄3 1⁄2 3⁄4 1 11⁄2 2 21⁄2 3 3⁄4 1 1 1- 1⁄2 1- 1⁄2 2 2 3 3 1.85 1.40 1.85 1.25 1.60 1.20 1.35 1.20 1.60 1⁄2 3⁄4 1 11⁄2 2 21⁄2 3 4 service Factor 1.60 1.00 1.50 1.00 1.40 1.00 1.30 1.00 1.20 1.20 1.00 1.15 1.25 B126 B227SE B127 B228SE B128 B229SE B129 B230SE B836 B130 B231SE B131 — B657 B657 B638 B638 B654 B654 B796 B796 — B809 B809 B818 B116 Group “B” C-face Keyed Shaft (56C) Hp ⁄2 ⁄4 1 3 1 11⁄2 2 3 Centurion® standardefficiency service Alum. Factor Voltage Cat.no. 1.60 1.50 1.40 1.30 1.20 1.20 1.15 230/115 230/115 230/115 230/115 230/115 230 230 B120 B121 B122 B123 B835 B124 B125 1.95 1.30 1.95 1.25 1.65 1.25 1.65 1.10 1.50 1.50 1.10 1.30 1.04 1.15 230/115 23˜0/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230 230 230 230 208-230 — B856 B846 B852 B847 B853 B848 B854 B858 B849 B855 B748 B840 –– — — B845 — B2661 — B2841 — –– B2842 — B2843 — B2844 service Voltage Cat.no. 208-230/115 208-230/115 208-230/115 208-230/115 208-230/115 208-230/115 208-230 208-230 208-230 SN1072 USN1102 SN1102 USN1152 SN1152 USN1202 SN1202 USN1302 SN1302 Group “D” Pool Cleaner Replacement e-Plus® e nergyefficient Alum. Castiron Cat.no. Cat.no. B656 B634 B653 B795 –– B808 B817 –– B631 B723 B750 –– B772 B774 Hp ⁄4 3 service Factor Voltage shaft Brand Cat.no. 1.50 1.50 1.50 1.50 1.50 230/115 230/115 230/115 230/115 230/115 Threaded Threaded Threaded Threaded Threaded Polaris ArnesonUniseal ArnesonUniseal Letro Letro B625 B662 B663 B667 B668 PHONE: (866) 887-5216 Pool, Spa and Jetted Tubs Thru-Bolt Motor Replacement Guide To select the correct thru-bolt replacement motor, complete steps 1 through 4. 1 . 2 . Is the manufacturer and model of your pump in the list of pump manufacturers and models below? If yes, the Century® motors from Group S and Group T in the tables below will fit your pump . Replacement motor horsepower must be equal to or greater than maximum rated horsepower . Identify the maximum rated horsepower of your motor . Maximum Rated Hp = Horsepower (Hp) x Service Factor (SF) Group S Single-speed Voltage Cat.no. 115 115 115 230/115 115 230/115 BN23SS BN24V1 BN25V1 BN35SS BV35V1 BN40SS ⁄2 3⁄4 1 11⁄2 11⁄2 2 What is the voltage? 4 . Is the motor single- or two-speed? If single-speed select motor from Group S . If two-speed, select motor from Group T . Group T Two-speed Hp(Max.rated) 1 3 . Pump Manufacturer & Model American Products Group American II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or Maxim “C” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or Maxim “S” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or Aqua Flo Flo-Master . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or Tub Master . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G/G Industries Olympian . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gruber Dura-Flo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hayward Mfg. Matrix Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Flo 1500 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Flo II 1700 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Flo II 1900 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Flo UN Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or Power Flo UN-LX Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or Power Flo II UN Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Flo 1900SD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hoffinger, Doughboy and Lomart Cat. No. Hp Threads Rotation BV90 1 .0 Right Hand CW BV91 1 .0 Left Hand CCW Hp(Max.rated) T T T T S S S S S S S T T T S Replaces Hoffinger # 300-1028 (1 Hp) 300-1027 (3⁄4 Hp) 300-1043 (1 Hp) 300-1017 (3⁄4 Hp) Jacuzzi Bros. Inno-Tech J Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S JCM Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Vector LVL Series* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Voltage Cat.no. 115 115 115 115 115 230 230 230 BN36 BN37 BN38 BN50 BN60 BN34 BN51 BN61 ⁄4/.10 1/.12 1/.16 11⁄2/.25 11⁄2/.18 112/.18 2/.25 2/.25 3 Pump Manufacturer & Model Jacuzzi Bros. (continued) Group LTVL Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T SLR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S LRDV Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S LCU Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T LTCU Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T LCM Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S LTCM Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T PAC-FAB Dynamo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Dynamite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Premier/Springwater 220-225-255 MKii Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T 300, 320, 325, 355 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Speck Model E90 and E91 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Sta-Rite Dura-Jet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Vico/Ultra-Jet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Ultra Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Waterway Bath Pump Self Drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Hi-Flo Side Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Hi-Flo Center Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T SVL56 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C Super Flo Side Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Workhorse Side Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T note: * Pump rated for 115/230 Volt, check voltage supply to ensure replacement motor is suitable. www.pool-motors.com A. O. Smith Two Compartment to Motor Replacement Guide Group “SK” Hp service Factor 1/2 3/4 1 1 .5 2 3 1 .6 1 .5 1 .5 1 .3 1 .3 1 .115 Voltage stock number 115/230 115/230 115/230 115/230 230 230 SK1052 SK1072 SK1102 SK1152 SK1202 SK1302V1 Conservationist CK1052 CK1072 CK1102 SK1152 SK1202 SK1302V1 Group “SP” Hp Voltage Brand stock number 3/4 3/4 115/230 115/230 Arneson Arneson SPS1052 RPS1052 Group “SQ” Hp service Factor Voltage stock number 1/2 1/2 3/4 3/4 1 1 1-1/2 1-1/2 2 2 2-1/2 3 1 .9 1 .3 1 .65 1 .27 1 .65 1 .25 1 .47 1 .1 1 .3 1 .1 1 .0 1 .15 115/230 115/230 115/230 115/230 115/230 115/230 230 115/230 230 230 230 230 SQ1052 USQ1052 SQ1072 USQ1072 SQ1102 USQ1102 SQ1152 USQ1152 SQ1202 USQ1202 USQ1252 SQ1302V1 Conservationist QC1052 QC1072 UQC1072 QC1102 UQC1102 SQ1152 UQC1152 SQ1202 USQ1202 USQ1252 SQ1302V1 Hp service Factor Voltage stock number 1/2 3/4 3/4 1 1 1-1/2 1-1/2 2 2 2-1/2 3 1 .6 1 .5 1 .0 1 .5 1 .0 1 .3 1 .0 1 .3 1 .0 1 .0 1 .15 115/230 115/230 115/230 115/230 115/230 115/230 115/230 208-230 115/230 208-230 208-230 ST1052 ST1072 UST1072 ST1102 UST1102 ST1152 UST1152 ST1202 UST1202 UST1252 ST1302V1 Conservationist CT1052 CT1072 Americana, American Eagle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ST American Ultra Flow or Power Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SQ Aqua-Flo C-Face . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SK Aqua-Flo Dominator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SQ Arneson Pool Sweep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SP Hayward Super & Super II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ST Hayward Max-Flo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ST Hydrotech . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ST ITT Marlow Argonaut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ST Jacuzzi Bronze, Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SK Jacuzzi Magnum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ST Pac Fab Challenger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SQ Pac Fab Hydro Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SK Premier/Springwater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SK Starite Duraglas or Maxiglas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SQ Speck . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ST Wet Institute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SK Please Note: Everyefforthasbeenmadetoensurethe A.O.Smithcannot,however,accept CT1012 responsibilityforultimateselection.OEM ST1152 designchangesandvariationsfromone ST1202 OEMtoanothermayresultindifferent ST1302V1 Above Ground and Spa Applications 1/2 3/4•1/8 3/4 1•1/6 1 Group Class accuracyofthisguide. Group “ST” Hp Name of Pump OEM or Brand Name service Factor Voltage stock number 1 .0 1 .0 1 .0 1 .0 1 .0 115 115 115 115 115 BN23SS BN36* BN24V1 BN37* BN25V1 construction,dimensionsoroperating characteristics.Itisyourresponsibilityto confirmtheacceptabilityofthesuggested replacement. notes: *2 Speed Please contact your local distributor with motor model number, frame size, horsepower, service factor, voltage and pump OEM model number for proper spa or above ground motor identification. PHONE: (866) 887-5216 )WCTFKCP2QQN/QVQTU5KPING5RGGF Guardian Pool Motors • Single-Speed '#5;61+056#..±2416'%6527/2±+/2418'5211.5#('6; Features: • • • • • • • Easy to install Auto-Reset Auto-Calibration Ball Bearing Economical 60 HZ Stainless Steel Shaft • • • • • • • Nerve Center (lighting sequence) 3/4 to 3 HP Single-Speed Single Phase Run/Restart/Rest/Bypass Mode Tamper-Resistant Housing Compatible with all flow rates Upgrad ed Elect ronics! USQG1152A Applications: A. O. Smith Guardian® motors comply with requirements for safety vacuum release systems in the Virginia Graeme Baker Pool and Spa Safety Act of 2007. Guardian® motors on this page pass ASME A112.19.17 SVRS standard. Guardian® motors will not prevent evisceration, hair, object or partial limb entrapment and is designed for suction lift applications. HP RPM Max. Amps Service Factor Frame 115/230 115/230 115/230 208-230 208-230 15.0/7.5 18.6/9.3 18.6/9.3 12.6/11.4 14.5/13.8 1.10 1.50 1.00 1.32 1.15 56J 56J 56J 56J 56J 230/115 230/115 230 230 7.2/14.4 9.2/18.4 10.5 14.1 1.40 1.30 1.20 1.15 11.8/5.9 14.8/7.4 19.2/9.6 11.2 15.4 Volts Stock Number Shaft Approx. “AG” USTG1102A STG1102A USTG1152A STG1202A STG1302A Threaded Threaded Threaded Threaded Threaded 11 12-1/8 12-1/8 13-1/16 14-3/16 56J 56J 56J 56J BG128A BG129A BG130A BG131A Threaded Threaded Threaded Threaded 10 11 10-1/2 11-9/16 1.27 1.25 1.10 1.30 1.15 48Y 48Y 48Y 48Y 56Y USQG1072A USQG1102A USQG1152A SQG1202A SQG1302A Threaded Threaded Threaded Threaded Threaded 11-1/2 12-1/8 13-1/8 13-7/8 14 BG853A BG848A BG854A BG855A BG748A BG2844A Threaded Threaded Threaded Threaded Threaded Threaded 9-7/8 10-1/4 10-1/4 10-7/8 12-3/4 13-5/8 Special Threaded 10-1/4 222 TWO COMPARTMENT, C-FACE 1 1 1-1/2 2 3 3450 3450 3450 3450 3450 CENTURION, C-FACE 1 1-1/2 2 3 3450 3450 3450 3450 Notes TWO COMPARTMENT, SQUARE FLANGE 3/4 1 1-1/2 2 3 3450 3450 3450 3450 3450 115/230 115/230 115/230 230 230 CENTURION, SQUARE FLANGE 1 1 1-1⁄2 2 2 3 3450 3450 3450 3450 3450 3450 230/115 230/115 230/115 230 230 208-230 7.1/14.2 8.0/16.0 8.0/16.0 10.0 11.5 15.0-13.6 1.25 1.65 1.10 1.10 1.30 1.15 56Y 56Y 56Y 56Y 56Y 56Y 3450 115/230 12.8/6.4 1.50 56CZ POLARIS POOL CLEANER 3/4 Notes: Guardian® SVRS helps prevent body entrapment on drains due to suction only. It does NOT protect against the four other types of entrapment: 222. Does not have Aluminum Adapter Bracket Guardian® Motors Also: Facilitates no main drain pool designs in place of an equalizer line. Guardian® motors shut off the motor/pump when the water level drops below the skimmer. Reduces pump, motor and seal damage. Shut off the motor/pump if any of the following conditions occur: Dry, blocked or jammed pump conditions; locked rotor, loss of prime, or abnormal voltage variations. Detect clogged or blocked filters and shuts down the pump. BE625 AG Hair Entanglement: if long hair is pulled into some drains by the flowing water, it can become knotted or snagged, trapping the swimmer underwater and leading to drowning. Mechanical Entrapment: small items or body parts (e.g., jewelry, swimsuit , hair decorations, fingers, toes, or knuckles) can be caught in some drains or drain covers, trapping the swimmer underwater and leading to drowning. Limb Entrapment: arms or legs can become trapped in uncovered drains, leading to drowning. Evisceration/Disembowelment: if a person sits on some drains, the suction can pull the lower intestine out of the rectum, causing irreversible damage. YYYCQUOKVJOQVQTUEQO www.pool-motors.com 221 6YQ%QORCTVOGPV0'/#%(CEG2QQN(KNVGT/QVQTU5KPING5RGGF Two Compartment NEMA C-Face Pool Filter Motors • Single-Speed Features: • • • • • Auto Protector • Capacitor Start and Capacitor Start-Capacitor Run NEMA “56C” Face Mount Open Dripproof • Rotation: CCW Pump End • Sealed Ball Bearings Sealed Switch Design • “1081” Design • 50°C Ambient • 60 Hz 303 Stainless Shaft (56J & 56C) • 304 Brg. Shaft End SK1072 CT1072 HIGH SERVICE FACTOR (FULL RATED)- STANDARD EFFICIENCY AND “CONSERVATIONISTTM” HIGH EFFICIENCY DESIGNS HP 1/2 3/4 1 1-1/2 2 3 RPM 3450 3450 3450 3450 3450 3450 Volts 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/208-230 230 208-230 230 208-230 Max. Service Amps Factor 10.6/5.3 1.6 8.0/4.0 1.6 11.0/5.5 1.6 8.0/4.0 1.6 14.6/7.3 1.5 11.0/5.5 1.5 15.0/7.5 1.5 11.0/5.5 1.5 17.0/8.5 1.5 13.6/6.8 1.4 18.6/9.3 1.5 13.6/6.8 1.4 19.4/9.7 1.3 19.6/10.4-9.8 1.5 11.2 1.3 12.6-11.4 1.3 14.4 1.15 14.5-13.8 1.15 Notes: Frame 56C 56C 56J 56J 56C 56C 56J 56J 56C 56C 56J 56J 56C 56J 56C 56J 56C 56J 20. $ Energy Efficient capacitor start, capacitor run “ConservationistTM” motor See page 268 for mounting dimensions. H Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.go Stock Number SK1052 CK1052 H ST1052 CT1052 H SK1072 CK1072 ST1072 CT1072 SK1102 CK1102 ST1102 CT1102 SK1152 ST1152 SK1202 ST1202 SK1302V1 ST1302V1 Shaft Key Key Thd. Thd. Key Key Thd. Thd. Key Key Thd. Thd. Key Thd. Key Thd Key Thd. Approx. “AG” 11 11 10-5/8 11 11-9/16 11-11/16 11 11-11/16 12-1/8 12-1/8 12-1/8 12-1/8 12-5/8 12-5/8 13-1/16 13-1/16 13-5/8 14-3/16 Notes 20,$ 20,$ 20,$ 20,$ 20,$ 20,$ 20,$ 20,$ 20,$ 20,$ 20,$ 20,$ Important: 1. Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced. 2. The pool motors on this page are NOT equipped with a Safety Vacuum Release System (SVRS). SVRS helps prevent drowning due to body entrapment on underwater drains. In some pool configurations, if a person’s body covers the drain, the person can be trapped by suction. The SVRS turns off the pump if this occurs. Depending on your pool configuration, a SVRS may be required to meet local, state, and federal requirements. YYYCQUOKVJOQVQTUEQO 209 PHONE: (866) 887-5216 6YQ%QORCTVOGPV0'/#%(CEG2QQN(KNVGT/QVQTU5KPING5RGGF Two Compartment NEMA C-Face Pool Filter Motors • Single Speed Features: • • • • • Auto Protector • Capacitor Start and Capacitor Start-Capacitor Run NEMA “56C” Face Mount Open Dripproof • Rotation: CCW Pump End • Sealed Ball Bearings Sealed Switch Design • “1081” Design • 50°C Ambient • 60 Hz 303 Stainless Shaft (56J & 56C) • 304 Brg. Shaft End UST1072 LOW SERVICE FACTOR (UP-RATED) - STANDARD EFFICIENCY AND “CONSERVATIONISTTM” HIGH EFFICIENCY DESIGNS HP RPM Volts Max. Amps Service Factor Frame 3/4 1 1-1/2 3450 3450 3450 3450 3450 115/230 115/230 115/230 115/230 115/230 115/230 115/208-230 208-230 11.0/5.5 8.0/4.0 15.0/7.5 11.0/5.5 18.6/9.3 14.6/7.3 19.6/10.4-9.8 12.6/11.4 1.0 1.0 1.1 1.0 1.0 1.0 1.1 1.1 56J 56J 56J 56J 56J 56J 56J 56J 2 2-1/2 Notes: Stock Number UST1072 UCT1072 H UST1102 UCT1102 UST1152 UCT1152 UST1202 UST1252 Approx. Shaft “AG” Thd. Thd. Thd. Thd. Thd. Thd. Thd. Thd. 10-5/8 11 11 11-11/16 12-1/8 12-1/8 12-5/8 13-1/16 Notes 20,$ 20,$ 20,$ 20,$ 20,$ Important: 6YQ%QORCTVOGPV0'/#%(CEG2QQN(KNVGT/QVQTU6YQ5RGGF 1. Total output (HP x service factor) of replacement motor 20. $ Energy Efficient capacitor start, capacitor run “ConservationistTM” motor must equal or exceed motor being replaced. 2. The pool motors on this page are NOT equipped with a SafetyWindings Vacuum Release System (SVRS). SVRS helps Steel Threaded Shaft • All Copper prevent drowning due to body entrapment on underwater • Open Dripproof • Rotation: CCW Pump End • Sealed Ball Bearings (304 Shaft End) drains. In some pool configurations, if a person’s body Features: • Sealed Switch Design • “1081” Design • 40°C Ambient • 60 Hz covers the drain, the person can be trapped by suction. TheWindings SVRS turns off the pump if this occurs. Auto Protector • Capacitor Start/Capacitor Run • 303 Stainless Steel Threaded Shaft • All Copper H Meets California Energy Commission Appliance Regulations 2008 Features: (Publication Number CEC-400-2006-002-REV1) Auto Protector • Capacitor Start/Capacitor Run • 303 Stainless www.energy.ca.gov Two Compartment NEMA C-Face Pool Filter Motors • Two Speed 6YQ%QORCTVOGPV0'/#%(CEG2QQN(KNVGT/QVQTU6YQ5RGGF • Open • Rotation: CCW Pumppool Endfilter • Sealed Bearings (304 Shaft End) to meet the rugged Depending on your pool configuration, A. O. Dripproof Smith NEMA C flange swimming pump Ball motors are carefully engineered a SVRS may be required to meet local, state, and federal • Sealed Switch Design “1081” Design • 40°C (with Ambient 60 Hz STS1072RV1 demands of pool duty. •Two sealed ball bearings large• 304 bearing on shaft end) offer ample capacity requirements. for extended life. Bearings are selected for quietness and are lubricated for life with greases specifically A. chosen O. Smith C flange swimming pool filter pump motorsend areframes carefully meet thefor rugged forNEMA moisture and heat resistant qualities. Aluminum areengineered accuratelyto machined maximum STS1072RV1 demands of pooland duty. Two sealed ball bearings (with large 304 bearing on shaft end) offer ample capacity concentricity minimum runout. for extended life. Bearings are selected for quietness and are lubricated for life with greases specifically chosen for moisture resistant qualities. frames are for maximum Two-speed motorsand are heat shipped less hi/lo switchAluminum for remoteend operation. Endaccurately cover andmachined switch assembly kit number 1011431-001 available and sold concentricity and minimum runout. separately. Two-speed motors are shipped less hi/loMax. switch for remote operation. End cover and switch assembly kit number 1011431-001 available and sold Amps Service Stock Approx. HP RPM Volts Hi - Lo Factor Frame Number Shaft “AG” Notes separately. 3/4~1/8 3450/1725 3/4~1/10 3450/1725 3450/1725 HP1~1/6 RPM 1~1/8 3450/1725 3/4~1/8 3450/1725 1-1/2~1/4 3450/1725 3450/1725 3/4~1/10 2~1/3 3450/1725 1~1/6 3450/1725 2~1/3 3450/1725 1~1/8 3450/1725 230 6.4/1.9 1.5 56J 230 5.4/2.2 1.5 56J Max. Amps Service 230 1.5 56J Volts Hi 8.5/2.5 - Lo Factor Frame 230 7.0/2.3 1.5 56J 230 6.4/1.9 1.5 56J 230 9.0/3.3 1.3 56J 230 5.4/2.2 1.5 56J 230 11.4/4.1 1.2 56J 230 8.5/2.5 1.5 56J 230 11.4/4.1 1.2 56J 230 7.0/2.3 1.5 56J Notes: 1-1/2~1/4 3450/1725 230 9.0/3.3 1.3 56J 1. Item to be discontinued when is depleted 2~1/3 3450/1725 230stock 11.4/4.1 1.2 56J 20. $ Energy Efficient capacitor start, capacitor run “Conservationist” motor 2~1/3 3450/1725 230 11.4/4.1 1.2 56J 90. 50 degree C ambient Notes: See page 268 for mounting dimensions. 1. Item to be discontinued when stock is depleted H Meets California Energy Commission Appliancerun Regulations 2008 20. $ Energy Efficient capacitor start, capacitor “Conservationist” motor (Publication CEC-400-2006-002-REV1) 90. 50 degreeNumber C ambient www.energy.ca.gov See page 268 for mounting dimensions. H Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov 1 STS1072R Thrd 12-1/8 STS1072RV1 H Thrd 12-1/8 90,$ Stock Approx. STS1102R Thrd 13-1/16 1,90 Number Shaft “AG” Notes H STS1102RV1 Thrd 12-1/2 1 90$ STS1072R Thrd 12-1/8 H STS1152R H Thrd 13-1/16 $ ,$ STS1072RV1 Thrd 12-1/8 90,20 STS1202R H Thrd 13-3/4 1,20,$ STS1102R Thrd 13-1/16 1,90 STS1202RV1 Thrd 13-3/4 H H Thrd $ ,$ STS1102RV1 12-1/2 9020 Important: STS1152R H Thrd 13-1/16 20,$ 1. Thrd Total output 13-3/4 (HP x service factor) of replacement motor STS1202R H 1,20,$ must equal or exceed motor being replaced. STS1202RV1 H Thrd 13-3/4 20,$ 2. The pool motors on this page are NOT equipped with a Important: Safety Vacuum Release System (SVRS). SVRS helps 1. Total outputdrowning (HP x service of replacement motor prevent due tofactor) body entrapment on underwater must equalInorsome exceed motor being replaced. drains. pool configurations, if a person’s body 2. Thecovers pool motors on the thisperson page are equipped a the drain, canNOT be trapped bywith suction. Safety Vacuum Release SVRS helps The SVRS turns off theSystem pump if(SVRS). this occurs. prevent drowning due to body entrapment on underwater Depending onifyour pool configuration, drains. In some pool configurations, a person’s body a SVRS may bethe required meet local, state, and federal covers the drain, persontocan be trapped by suction. Therequirements. SVRS turns off the pump if this occurs. Depending on your pool configuration, a SVRS may be required to meet local, state, and federal requirements. 210 www.pool-motors.com YYYCQUOKVJOQVQTUEQO 0'/#%(CEG2JCUG2WOR/QVQTU NEMA C-Face 3-Phase Pump Motors Features: • Ball Bearings • Continuous Duty • Internal Junction Box • Keyed and Stainless Steel Threaded Shafts • NEMA “56C” Mount • Open Dripproof • 40°C Ambient • 60 Hz T3052 NEMA C Face mounting bracket, and end frames are die-cast corrosion resistant aluminum, accurately machined for maximum concentricity, and minimum runout. Stator assemblies are press fitted into rolled steel main frames. Double shielded ball bearings, selected for quiet operation, are lubricated for life with greases specifically chosen for moisture and heat resistant qualities. 1/2” x 14 thread tapped opening is provided for conduit fitting. No external junction box required connections made under motor canopy. Motors are supplied with horizontal canopy but are easily converted for vertical operation with the use of optional vertical canopy (#621335-002). HP 1/2 3/4 1 1-1/2 2 RPM 3450 3450 3450 3450 3450 Volts 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 Max. Amps 2.7/1.35 3.4/1.7 3.4/1.7 4.0/2.0 4.0/2.0 6.8/3.4 6.8/3.4 8.6/4.3 8.6/4.3 Service Factor 1.6 1.5 1.5 1.4 1.4 1.3 1.3 1.2 1.2 Frame 56J 56C 56J 56C 56J 56C 56J 56C 56J Stock Number T3052 K3072 T3072 K3102 T3102 K3152 T3152 K3202 T3202 Shaft Thrd Key Thrd Key Thrd Key Thrd Key Thrd Protector None None None None None None None None None Approx. “AG” 8-5/8 9-1/8 9-1/8 9-11/16 9-11/16 11-5/16 11-5/16 11-5/16 11-5/16 Notes Important: 1. Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced. 2. The pool motors on this page are NOT equipped with a Safety Vacuum Release System (SVRS). SVRS helps prevent drowning due to body entrapment on underwater drains. In some pool configurations, if a person’s body covers the drain, the person can be trapped by suction. The SVRS turns off the pump if this occurs. Depending on your pool configuration, a SVRS may be required to meet local, state, and federal requirements. 212 YYYCQUOKVJOQVQTUEQO PHONE: (866) 887-5216 %GPVWT[%(CEG2QQNCPF5RC2WOR/QVQTU Century® C-Face Pool and Spa Pump Motors 2GTOCPGPV5RNKV%CRCEKVQT±5YKVEJNGUU±5KPING2JCUG±&TKRRTQQH 0Q$CUG±42/VJTW*2 Features: • Ball Bearings • 50°C Ambient • 60 Hz • Class B Insulation • Rotation: CCW Pump End • 304 Bearing Shaft End B126 Centurion® “1081” • Full Rate • High Service Factor • Aluminum NEMA “C” Brackets HP 1/2 3/4 1 1-1/2 2 3 4 RPM 3450 3450 3450 3450 3450 3450 3450 Volts 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230 230/115 230 230 230 208-230 Service Factor Amps 4.4/8.8 4.4/8.8 6.0/12.0 6.0/12.0 7.2/14.4 7.2/14.4 9.2/18.4 9.2/18.4 10.8/21.6 10.5 10.8/21.6 10.5 14.1 14.1 21.0-19.4 Service Factor Frame 1.60 1.60 1.50 1.50 1.40 1.40 1.30 1.30 1.20 1.20 1.20 1.20 1.15 1.15 1.25 56C 56J 56C 56J 56C 56J 56C 56J 56C 56C 56J 56J 56C 56J 56Y Stock Number B120 H B126 H B121 B127 B122 B128 B123 B129 B835 B124 B836 B130 B125 B131 B116 Overload Protector Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Manual Shaft “C” Dimension Keyed Threaded Keyed Threaded Keyed Threaded Keyed Threaded Keyed Keyed Threaded Threaded Keyed Threaded Special 11.44 11.94 11.44 12.01 11.89 12.14 13.19 13.50 13.94 12.55 13.90 13.10 13.65 14.15 16.78 12 31,34,63,236 Shaft “C” Dimension Notes 12.56 12.81 13.91 14.31 13.81 12 12 12 12 12 Notes 12 12 12 12 12 12 Centurion® SE “1081” • Up Rate • Low Service Factor HP 3/4 1 1-1/2 2 2-1/2 RPM 3450 3450 3450 3450 3450 Volts Service Factor Amps 230/115 230/115 230/115 230/115 230 4.4/8.8 6.0/12.0 7.2/14.4 9.2/18.4 10.5 Service Factor Frame 1.00 1.00 1.00 1.00 1.00 56J 56J 56J 56J 56J Notes: 12. 303 Stainless steel shaft 31. 40 degree C ambient 34. Rigid base 63. Speck Pump replacement motor 236. CCW Rotation facing opposite shaft end H Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov Stock Number B227SE H B228SE B229SE B230SE B231SE Overload Protector Auto Auto Auto Auto Auto Threaded Threaded Threaded Threaded Threaded Important: 1. Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced. 2. The pool motors on this page are NOT equipped with a Safety Vacuum Release System (SVRS). SVRS helps prevent drowning due to body entrapment on underwater drains. In some pool configurations, if a person’s body covers the drain, the person can be trapped by suction. The SVRS turns off the pump if this occurs. Depending on your pool configuration, a SVRS may be required to meet local, state, and federal requirements. YYYCQUOKVJOQVQTUEQO www.pool-motors.com 213 %GPVWT[%(CEG2QQNCPF5RC2WOR/QVQTU Century® C-Face Pool and Spa Pump Motors Continued from previous page 2GTOCPGPV5RNKV%CRCEKVQT±5YKVEJNGUU±5KPING2JCUG±&TKRRTQQH 0Q$CUG±42/VJTW*2 Features: • Ball Bearings • Class B Insulation • 304 Bearing Shaft End • 60 Hz • Rotation: CCW Pump End • Energy Efficient $ B638 E-Plus® Energy Efficient “1081” • Centurion® Motor • Full Rate • Aluminum NEMA “C” Brackets • 50˚C Ambient HP RPM Volts Service Factor Amps 1/2 3/4 1 1-1/2 2 3 3450 3450 3450 3450 3450 208-230/115 208-230/115 208-230/115 208-230/115 208-230/115 208-230/115 208-230/115 208-230 208-230 208-230 208-230 4.0-3.7/7.4 4.0-3.7/7.4 5.4-5.0/10.0 6.4-5.9/11.8 6.4-5.9/11.8 8.7-7.8/15.6 8.7-7.8/15.6 10.4-9.6 10.4-9.6 15.0-13.6 15.0-13.6 3450 Service Factor Frame 1.60 1.60 1.50 1.40 1.40 1.30 1.30 1.20 1.20 1.15 1.15 56C 56J 56J 56C 56J 56C 56J 56C 56J 56C 56J Stock Number B656 H B657 H B638 B653 B654 B795 B796 B808 B809 B817 B818 Overload Protector Shaft “C” Dimension Notes Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Keyed Threaded Threaded Keyed Threaded Keyed Threaded Keyed Threaded Keyed Threaded 11.51 11.95 12.69 12.55 13.19 13.19 13.55 13.65 14.15 13.65 14.15 1,$ 12,$ 12,$ $ 12,$ $ 12,$ $ 12,$ $ 12,$ Notes: 1. Item to be discontinued when present stock is depleted 12. 303 Stainless steel shaft H Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov Important: 1. Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced. 2. The pool motors on this page are NOT equipped with a Safety Vacuum Release System (SVRS). SVRS helps prevent drowning due to body entrapment on underwater drains. In some pool configurations, if a person’s body covers the drain, the person can be trapped by suction. The SVRS turns off the pump if this occurs. Depending on your pool configuration, a SVRS may be required to meet local, state, and federal requirements. 214 0 YYYCQUOKVJOQVQTUEQO PHONE: (866) 887-5216 %GPVWT[%(CEG2QQNCPF5RC2WOR/QVQTU Century® C-Face Pool and Spa Pump Motors Continued from previous page 2GTOCPGPV5RNKV%CRCEKVQT±5YKVEJNGUU±5KPING2JCUG±&TKRRTQQH 0Q$CUG±42/VJTW*2 Features: • Ball Bearings • Class B Insulation • 304 Bearing Shaft End • 60 Hz • Rotation: CCW Pump End • Energy Efficient $ B971 Two Speed “1081” • Full Rate • High Service Factor • 40°C Ambient HP RPM Volts Service Factor Amps Service Factor Frame Stock Number Overload Protector Shaft “C” Dimension Notes High Speed Switchless, Low Speed Microswitch • Aluminum “C” Bracket • Hi-Lo Toggle Switch available (P/N 17590450) 1/2~.06 3/4~.10 1~.12 1-1/2~.20 2~.25 3~.38 3450/1725 3450/1725 3450/1725 3450/1725 3450/1725 3450/1725 115 115 115 115 230 230 230 230 115 230 230 230 8.8/3.55 8.8/3.55 11.2/5.0 11.2/5.0 6.3/2.3 6.3/2.3 8.9/3.1 8.9/3.1 14.6/4.4 10.6/3.2 10.6/3.2 13.8/4.0 1.60 1.60 1.50 1.50 1.40 1.40 1.30 1.30 1.10 1.20 1.20 1.15 56C 56J 56C 56J 56C 56J 56C 56J 56J 56C 56J 56J B970 H B971 H B972 H B973 H B974 H B975 H B976 H B977 H B969 H B978 H B979 H B966 H Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Keyed Threaded Keyed Threaded Keyed Threaded Keyed Threaded Threaded Keyed Threaded Threaded 11.80 12.30 11.80 12.30 12.05 13.05 12.54 13.05 13.54 13.04 13.55 14.29 $ 12,$ $ 12,$ $ 12,$ $ 12,$ 12,63,90,$ $ 12,$ 12,$ E-Plus® Energy Efficient “1081” • Centurion® Motor • Full Rate • Cast Iron NEMA “C” Brackets • 50˚C Ambient HP RPM Volts Service Factor Amps 3/4 1 1-1/2 2 3 3450 3450 3450 3450 3450 208-230/115 208-230/115 208-230/115 208-230 208-230 5.4-5.0/10.0 6.4-5.9/11.8 8.7-7.8/15.6 10.4-9.6 15.0-13.6 Service Factor Frame Stock Number Overload Protector Shaft “C” Dimension Notes 1.50 1.40 1.30 1.20 1.15 56C 56C 56C 56C 56C B631 B723 B750 B772 B774 Auto Auto Auto Auto Auto Keyed Keyed Keyed Keyed Keyed 12.62 12.80 13.30 14.05 14.05 12,$ 12,$ 12,$ 12,$ 12,$ Notes: 12. 303 Stainless steel shaft 63. Speck Pump replacement motor 90. 50 degree C ambient H Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov Important: 1. Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced. 2. The pool motors on this page are NOT equipped with a Safety Vacuum Release System (SVRS). SVRS helps prevent drowning due to body entrapment on underwater drains. In some pool configurations, if a person’s body covers the drain, the person can be trapped by suction. The SVRS turns off the pump if this occurs. Depending on your pool configuration, a SVRS may be required to meet local, state, and federal requirements. YYYCQUOKVJOQVQTUEQO www.pool-motors.com 215 Two Compartment Square Flange Pool Filter Motors 6YQ%QORCTVOGPV5SWCTG(NCPIG2QQN(KNVGT/QVQTU 5KPING5RGGF'PGTI['HHKEKGPV Single Speed & Energy Efficient Used on many Sta-Rite, Red Jacket, Pac Fab and American Products. Features: • • • • Auto Protector • Capacitor Start Class B Insulation • Open Dripproof Rotation: CCW Pump End • 303 Stainless Steel Threaded Shaft Sealed Ball Bearings • 50°C Ambient • 60 Hz • UL1081 HIGH SERVICE FACTOR (FULL RATED) HP 1/3 1/2 3/4 1 1-1/2 2 3 RPM 3450 3450 3450 3450 3450 3450 3450 Volts 115/230 115/230 115/230 115/230 115/230 115/230 115/208-230 230 230 230 Max. Amps 9.9/5.0 13.4/6.7 9.6/4.8 15.3/7.6 12.6/6.3 19.2/9.6 16.0/8.0 10.4 11.2 15.4 SQ1152 SQ1032 Service Factor 1.95 1.9 1.9 1.65 1.65 1.65 1.65 1.47 1.3 1.15 Frame 48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y 56Y Stock Number SQ1032 SQ1052 QC1052 H SQ1072 QC1072 SQ1102 QC1102 SQ1152 SQ1202 SQ1302V1 Approx. “AG” 11-1/8 11-1/2 10-7/8 12-1/8 11-1/4 13-1/8 11-7/8 13-1/4 13-7/8 14 Service Factor 1.3 1.27 1.27 1.25 1.25 1.1 1.1 1.1 1.0 Frame 48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y Stock Number USQ1052 USQ1072 UQC1072 USQ1102 UQC1102 USQ1152 UQC1152 USQ1202 USQ1252 Approx. “AG” 11-1/8 11-1/2 10-7/8 12-1/8 11-1/4 13-1/8 13-1/4 13-1/4 13-7/8 Notes 20,$ 20,$ 20,$ 20,$ 20,$ 20,$ LOW SERVICE FACTOR (UP-RATED) HP 1/2 3/4 1 1-1/2 2 2-1/2 RPM 3450 3450 3450 3450 3450 3450 Volts 115/230 115/230 115/230 115/230 115/230 115/230 115/230 230 230 Max. Amps 9.9/5.0 13.4/6.7 9.6/4.8 15.3/7.6 12.6/6.3 19.2/9.6 16.0/8.0 10.4 11.2 Notes: 20. $ Energy Efficient capacitor start, capacitor run “Conservationist” motor See page 276 for mounting dimensions. H Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov H Notes 20,$ 20,$ 20,$ 20,$ 20,$ Important: 1. Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced. 2. The pool motors on this page are NOT equipped with a Safety Vacuum Release System (SVRS). SVRS helps prevent drowning due to body entrapment on underwater drains. In some pool configurations, if a person’s body covers the drain, the person can be trapped by suction. The SVRS turns off the pump if this occurs. Depending on your pool configuration, a SVRS may be required to meet local, state, and federal requirements. 216 YYYCQUOKVJOQVQTUEQO PHONE: (866) 887-5216 6YQ%QORCTVOGPV5SWCTG(NCPIG2QQN/QVQTU6YQ5RGGF Two Compartment Square Flange Pool Motors • Two-Speed Used on many Sta-Rite, Red Jacket, and Sears Jet and Pool Pumps. Features: • • • • All Copper Windings • Auto Protector - Single Phase Open Dripproof • Rotation: CCW Pump End • Class B Insulation 303 Stainless Steel Threaded Shaft • 50°C Ambient • 60 Hz Energy Efficient Capacitor Start Low Speed, PSC High Speed • UL1081 Two-speed motors are shipped less hi/lo switch for remote operation. End cover and switch assembly kit number 615332 available and sold separately. SQS1072R SQS1152R HIGH SERVICE FACTOR (FULL RATED) HP 3/4~1/8 1~1/6 1-1/2~1/4 2~1/3 RPM 3450/1725 3450/1725 3450/1725 3450/1725 Volts 115 230 230 230 230 Amps Hi - Lo 13.0/4.2 6.1/2.1 7.7/2.8 10.0/3.0 11.3/3.3 S.F. 1.65 1.60 1.65 1.47 1.3 Frame 48Y 48Y 48Y 48Y 48Y Stock Number SQL1072R SQS1072R SQS1102R SQS1152R SQS1202R Stock Number Approx. “AG” 12-5/8 12-5/8 13-13/16 13-9/16 13-13/16 H H H H H Notes $ $ $ $ $ LOW SERVICE FACTOR (UP-RATED) HP RPM 1~1/6 3450/1725 1-1/2~1/4 3450/1725 2~1/3 3450/1725 Volts Amps Hi - Lo S.F. Frame 230 230 230 6.1/2.1 9.5/2.5 10.0/3.0 1.25 1.1 1.1 48Y 48Y 48Y UQS1102R H UQS1152R H UQS1202R H Approx. “AG” Notes 12-5/8 13-13/16 13-9/16 $ $ $ THREE PHASE SQUARE FLANGE PUMP MOTORS Features: Q3052 All Copper Windings•Open Dripproof•303 Stainless Steel Threaded Shaft•Sealed Ball Bearings•50°C Ambient•60 HzFeaturd Ball Bearings HP RPM Volts Max. Amps Service Factor Frame Stock Number Overload Protector Approx. “AG” Notes 1/2 3/4 1 1-1/2 2 3 3450 3450 3450 3450 3450 3450 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 200-230/460 3.0/1.5 3.6/1.8 4.7/2.35 6.8/3.4 8.5/4.25 9.7/4.9 1.9 1.65 1.65 1.47 1.3 1.15 48Y 48Y 48Y 48Y 48Y 56Y Q3052 Q3072 Q3102 Q3152 Q3202 Q3302V1 None None None None None None 9-7/8 10-3/8 10-7/8 11-7/8 12-5/8 12 31 Notes: 31. 40 degree C ambient See page 276 for mounting dimensions. H Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov Important: 1. Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced. 2. The pool motors on this page are NOT equipped with a Safety Vacuum Release System (SVRS). SVRS helps prevent drowning due to body entrapment on underwater drains. In some pool configurations, if a person’s body covers the drain, the person can be trapped by suction. The SVRS turns off the pump if this occurs. Depending on your pool configuration, a SVRS may be required to meet local, state, and federal requirements. YYYCQUOKVJOQVQTUEQO www.pool-motors.com 217 %GPVWT[2QQNCPF5RC2WOR/QVQTU5SWCTG(NCPIG Century® Pool and Spa Pump Motors Square Flange 2GTOCPGPV5RNKV%CRCEKVQT±5YKVEJNGUU±5KPING2JCUG±&TKRRTQQH 0Q$CUG±CPF42/VJTW*2 Features: • Ball Bearings • 50°C Ambient • Rotation: CCW Pump End • $ Energy Efficient • 60 Hz • Class B Insulation • Stainless Steel Shafts Service Service HP RPM Volts Factor Amps Factor Centurion® “1081” • Full Rate • High Service Factor 1⁄2 3450 230/115 5.4/10.8 1.95 3⁄4 3450 230/115 7.1/14.2 1.65 1 3450 230/115 8.0/16.0 1.65 1-1⁄2 3450 230/115 10.5/21.0 1.50 230 10.0 1.50 2 3450 230 11.5 1.30 Centurion® “1081” • Up-Rate • Low Service Factor 1⁄2 3450 230/115 4.0/8.0 1.30 3⁄4 3450 230/115 5.4/10.8 1.25 1 3450 230/115 7.1/14.2 1.25 1-1⁄2 3450 230/115 8.0/16.0 1.10 2 3450 230/115 11.2/22.4 1.10 230 10.0 1.10 2-1⁄2 3450 230 11.5 1.04 Centurion® II “1081” • Up-Rate • Low Service Factor 1⁄2 3450 230/115 3.6/7.2 1.30 E-Plus® Energy Efficient “1081” • New Centurion • Full Rate 1⁄2 3450 208-230/115 4.5-4.4/8.8 1.90 3⁄4 3450 115/208-230 6.0-5.6/11.2 1.67 1 3450 115/208-230 7.8-7.4/14.8 1.65 1-1⁄2 3450 208-230 9.6-8.8 1.47 2 3450 208-230 11.0-10.2 1.30 3 3450 208-230 15.0-13.6 1.15 208-230 15.0-13.6 1.15 208-230 15.0-13.6 1.15 Notes: B2661 Frame Stock Number 218 Shaft Overload Protector “C” Dim. Notes 56Y 56Y 56Y 56Y 56Y 56Y B846 H B847 B848 B858 B849 B748 Threaded Threaded Threaded Threaded Threaded Threaded Auto Auto Auto Auto Auto Auto 12.4 12.4 12.8 14.4 13.4 13.4 56Y 56Y 56Y 56Y 56Y 56Y 56Y B856 H B852 H B853 B854 B859 B855 B840 Threaded Threaded Threaded Threaded Threaded Threaded Threaded Auto Auto Auto Auto Auto Auto Auto 12.4 12.4 12.4 12.8 14.4 13.4 13.4 1 48Y B856SM H Threaded Auto 12.3 1,158,235 56Y 56Y 56Y 56Y 56Y 56Y 56Y 56Y B845 H B2661 B2841 B2842 B2843 B844 B844A B2844 Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded Auto Auto Auto Auto Auto Auto Auto Auto 12.4 13.1 13.4 13.9 14.4 14.4 14.4 14.4 $ 1.Item to be discontinued when present stock is depleted 158. Open motor construction, overloadprotector mounted at 12 o’clock 235. Centurion II motors are switchless. Designed in a 48-frame shell diameter that is .80 inches smaller in diameter than the 56-frame Centurion and Centurion SE designs. 352. Pentair, almond paint, direct replacement motor H Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov B852 1,$ 1,352,$ Important: 1. Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced. 2. The pool motors on this page are NOT equipped with a Safety Vacuum Release System (SVRS). SVRS helps prevent drowning due to body entrapment on underwater drains. In some pool configurations, if a person’s body covers the drain, the person can be trapped by suction. The SVRS turns off the pump if this occurs. Depending on your pool configuration, a SVRS may be required to meet local, state, and federal requirements. YYYCQUOKVJOQVQTUEQO PHONE: (866) 887-5216 Century® Pool and Spa Pump Motors Square Flange New from A. O. Smith – High Efficiency two-speed motors. New Centurion High Efficiency two-speed motors have PSC (Permanent Split Capacitor) high speeds and PSC low speeds. The PSC high speeds have always saved energy but until now the low speeds were standard efficient. New Centurion twospeed motors have PSC low speeds which improves efficiency up to 20%. New Centurion High Efficiency Two-Speed Pool and Spa Motors Features: • Ball Bearing • Class B Insulation • 50˚C Ambient • $ High Efficient High and Low Speed • Open Dripproof • Permanent Split Capacitor • Rotation: CCW Pump End • Single Phase • 303 Stainless Steel Shafts B2980 Two-Speed - “1081” - pSC energy effiCienT HigH Speed - pSC energy effiCienT Low Speed - Square fLange - fuLL raTe HP 3⁄4~.10 3⁄4~.10 1~.13 1-1/2~.19 2~.25 2~.33 RPM 3450/1725 3450/1725 3450/1725 3450/1725 3450/1725 3450/1725 Volts 230 115 230 230 230 230 230 Service Factor Amps 6.0/1.0 12.4/2.2 7.4/1.4 10.0/1.6 11.0/1.8 11.0/4.0 10.0/3.5 Service Factor 1.67 1.67 1.65 1.47 1.30 1.30 1.10 Frame 56Y 56Y 56Y 56Y 56Y 56Y 56Y Stock Number B0 H B H B H B H B H B H B H Shaft Threaded Threaded Threaded Threaded Threaded Threaded Threaded Overload Protector Auto Auto Auto Auto Auto Auto Auto Length Includ. Shaft 13.1 13.1 13.4 13.9 14.4 14.3 13.8 Notes $ $ $ $ $ $ 107,$ H Meets California Energy Commission Appliance Regulations 2008 Permanent Split Capacitor – Switchless – Single Phase – Dripproof No Base – 3600 and 3600/1800 RPM 1/2 thru 3 HP Features: • Ball Bearing • Class B Insulation • Energy Efficient $ • 60 Hz • Rotation: CCW Pump End • 50˚C Ambient • Stainless Steel Shafts HP RPM Volts Service Factor Amps Service Factor Frame 3⁄4 3450 3450 208-230/115 208-230 4.5-4.4/8.8 9.6-8.8 1.25 1.10 56Y 56Y E-Plus® Energy Efficient “0” • Centurion SE • Up-Rate Notes: 1.Itemtobediscontinuedwhenstockisdepleted 107.Uprated–LowServiceFactor 158.Openmotorconstruction,overloadprotectormountedat12o’clock Stock Number BSE H BSE Shaft Overload Protector “C” Dim. Notes Threaded Threaded Auto Auto 13.6 15.0 1,158,$ 1,$ important: 1. Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced. 2. The pool motors on this page are noT equipped with a Safety Vacuum release System (SVrS). SVRS helps prevent drowning due to body entrapment on underwater drains. In some pool configurations, if a person’s body covers the drain, the person can be trapped by suction. The SVRS turns off the pump if this occurs. Depending on your pool configuration, a SVRS may be required to meet local, state, and federal requirements. www.pool-motors.com #DQXG)TQWPF5YKOOKPI2QQN2WOR/QVQTU Above Ground Swimming Pool Pump Motors ,GVVGF6WD5RC#DQXG)TQWPF5YKOOKPI2QQN2WOR/QVQTU±5RNKV2JCUG%CRCEKVQT 5VCTV25%5KPINGRJCUG±&TKRRTQQH±$CNN$GCTKPI±4KIKF$CUG0Q$CUG±CPF 42/±VJTW*252 Features: • 12 & 3 O’clock Conduit Entries • Rotation: CCW Pump End • 3-1/2” Shaft Height • 40˚C Ambient • Class B Insulation • Through Bolt Mount • 48/56 Base Mounting • Four Thru Bolts on a 5.146 Bolt Circle BN24SS Applications: Spa, above ground swimming pool and jetted tub pumps. Optional Flex-48 Accessories: Airswitch (#17800901), Single-speed Toggle Switch Assy. - On/Off (#18374501), Day/Night Controller (#18602400), Two-speed Toggle Switch Assy. - Lo/Off/Hi (#18313301) Century Flex-48 W/Stainless Steel Shaft & Ball Bearings • “1081” • “1795” • “1563” • Rigid Base HP 1⁄2 3⁄4 1 RPM 3450 3450 Hz 60 60 60 60 60 60 60 60 60 Full Load Amps 7.2 9.8 9.8 12.0 12.0 8.0/16.0 17.0 17.0 10.0/20.0 Service Factor 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Frame 48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y Stock Number BN23SS BN24SS BN24V1 BN25SS BN25V1 BN35SS BV35SS BV35V1 BN40SS Shaft Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded Overload Protector Auto Auto Auto Auto Auto Auto Auto Auto Auto “C” Dim. 11.08 11.08 11.08 11.58 11.58 12.08 12.08 12.08 13.33 1-1⁄2 3450 2 3450 Volts 115 115 115 115 115 230/115 115 115 230/115 3450/1725 3450/1725 3450/1725 3450/1725 3450/1725 115 115 115 230 230 60 60 60 60 60 8.8/2.6 11.0/2.9 16.4/4.4 8.0/2.6 10.5/2.6 1.0 1.0 1.0 1.0 1.0 48Y 48Y 48Y 48Y 48Y BN36 BN37 BN50 BN34 BN51 Threaded Threaded Threaded Threaded Threaded Auto Auto Auto Auto Auto 12.08 12.08 12.83 12.83 13.33 45 45 45 45 115 115 230 230 208-230 60 60 60 60 60 10.3/3.1 13.8/3.8 8.5/2.8 12.0/3.5 12.0/3.5 1.0 1.0 1.0 1.0 1.0 48Y 48Y 48Y 48Y 48Y BN38 BN60 H BN61 H BN62 H BN63 H Threaded Threaded Threaded Threaded Threaded Auto Auto Auto Auto Auto 12.83 12.83 13.33 14.33 14.33 45 68,145,$ 68,145,$ 68,90,145,$ 68,90,145,$ 3450 Century Flex 48 LASAR® Line (Low Amp Start and Run) • Two-speed • “1081” • “1563” • Rigid Base 3⁄4~.10 1~.12 1-1⁄2 ~.25 1-1⁄2 ~.18 2~.25 Century Flex 48 LASAR-XL • Extra Low Running Amps • Two-speed • Rigid Base 1~.12 3450/1725 1-1/2~.18 3450/1725 2~.25 3450/1725 3~.38 3450/1725 4.0~.42 SPL3450/1725 Notes: 1.Item to be discontinued when stock is depleted 45. Capacitor start 68. PSC Motor 90. 50˚C Ambient 145. Run capacitor mounted on motor shell H Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov 222 Notes 1 90 1 45 1 45 Continues on the next page Important: The pool motors on this page are NOT equipped with a Safety Vacuum Release System (SVRS). SVRS helps prevent drowning due to body entrapment on underwater drains. In some pool configurations, if a person’s body covers the drain, the person can be trapped by suction. The SVRS turns off the pump if this occurs. Depending on your pool configuration, a SVRS may be required to meet local, state, and federal requirements. YYYCQUOKVJOQVQTUEQO PHONE: (866) 887-5216 Continued from previous page #DQXG)TQWPF5YKOOKPI2QQN2WOR/QVQTU Above Ground Swimming Pool Pump Motors ,GVVGF6WD5RC#DQXG)TQWPF5YKOOKPI2QQN2WOR/QVQTU±5RNKV2JCUG%CRCEKVQT 5VCTV25%5KPINGRJCUG±&TKRRTQQH±$CNN$GCTKPI±4KIKF$CUG0Q$CUG±CPF 42/±VJTW*252 Hoffinger Replacement (Doughboy/Lomart) • No Base HP 1 RPM 3450 Notes: Volts 115 115 Full Load Amps 10.0 9.0 Hz 60 60 Service Factor 1.0 1.0 Frame 48Y 48Y BV90 Stock Number BV90 BV91 Shaft Threaded Threaded Overload Protector Auto Auto “C” Dim. 10.45 10.22 Notes 285 285. 3/8-16, Left hand threads, CWPE rotation H Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov 5VC4KVG&KTGEV4GRNCEGOGPV5RC/QVQTU Features: • • • • Open Construction Threaded Shaft 1.0 Service Factor Rotation: CCW Pump End • • • • Rigid Base • Sealed Ball Bearings Through Bolt Mount • 50˚C Ambient $ Energy Efficient • Auto Protector 2-Speed (Capacitor Start Low Speed, PSC High Speed) SDS1102 Four Thru Bolts on a 5.146 Bolt CircleReplacement Motor for Dimension One, Hydroquip, GPM Industries, Hawkeye, Marquis and Master Spas HP 1.0-.12 1.5-.19 2.0-.25 2.5-.25 3.0-.38 RPM 3450/1725 3450/1725 3450/1725 3450/1725 3450/1725 Volts 115 230 230 230 230 Amps 10.4/3.6 7.2/2.4 8.5/3.0 10.7/3.0 12.0/3.7 Frame 56Z 56Z 56Z 56Z 56Z Stock Number SDS1102 H SDS1152 H SDS1202 H SDS1252 H SDS1302 H Insulation Class B F F F F Approx. “AG” 10.30 10.79 11.42 10.67 10.92 Dim. “BX” 8.85 9.34 9.98 9.23 9.48 Notes $ $ $ $ $ Note: When crossing to an original equipment A. O. Smith Motor, use the Quick Cross Reference table. Find the amps and model number of the OEM motor on the motor nameplate. Find the equivalent amps and model number on the Quick Cross Reference table below. The replacement is the stock number listed in the “Use” column. The horsepower and service factor may not be the same, but the motors are the same. QUICk CROSS REFERENCE By AMPS AND MOTOR MODEL NUMBER Name Plate Name Plate Use Amps Model No. Stock No. 10.4/3.6 K48L2A1 SDS1102 7.2/2.4 K48M2A4 SDS1152 8.5/3.0 K48N2A5 SDS1202 10.7/3.0 K48N2A4C2 SDS1252 12.0/3.7 K48P2A1 SDS1302 H Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov Important: The pool motors on this page are NOT equipped with a Safety Vacuum Release System (SVRS). SVRS helps prevent drowning due to body entrapment on underwater drains. In some pool configurations, if a person’s body covers the drain, the person can be trapped by suction. The SVRS turns off the pump if this occurs. Depending on your pool configuration, a SVRS may be required to meet local, state, and federal requirements. YYYCQUOKVJOQVQTUEQO www.pool-motors.com 223 %GPVWT[5YKOOKPI2QQN2WOR/QVQTU Century® Swimming Pool Pump Motors 5SWKTTGN%CIG 6JTGG2JCUG±&TKRRTQQH±42/±VJTW*2 Features: • Ball Bearings • Cast Iron NEMA “C” Bracket • 50/60 Hz • 40˚C Ambient • 303 Stainless Steel Shaft • Class A or B Insulation • Reversible (Three Phase) H281 60/50 Hz • Three Phase “1081” • Full Rate • High Service Factor HP 1⁄2 3⁄4 1 1-1⁄2 2 3 RPM 3450 3450 3450 3450 3450 3450 Service Factor Volts Amps@ 60 Hz 208-230/460 2.1-2.4/1.2 208-230/460 2.1-2.4/1.2 208-230/460 3.7-3.6/1.8 208-230/460 3.7-3.6/1.8 208-230/460 4.3-4.0/2.0 208-230/460 4.3-4.0/2.0 208-230/460 5.9-5.6/2.8 208-230/460 5.9-5.6/2.8 208-230/460 7.0-6.6/3.3 208-230/460 7.0-6.6/3.3 208-230/460 9.6-9.2/4.6 208-230/460 9.6-9.2/4.6 Service Factor 1.60 1.60 1.50 1.50 1.40 1.40 1.30 1.30 1.20 1.20 1.15 1.15 Stock Number H281 H282 H450 H451 H513 H514 H616 H617 H704 H705 H740 H741 Frame 56C 56J 56C 56J 56C 56J 56C 56J 56C 56J 56C 56J Shaft Keyed Threaded Keyed Threaded Keyed Threaded Keyed Threaded Keyed Threaded Keyed Threaded Overload Protector None None None None None None None None None None None None Insul. Class A A A A A A A A A A B B “C” Dim. 11.87 12.05 12.80 12.12 12.62 12.12 13.24 12.62 13.62 13.12 13.30 13.12 Notes 282 282 282 282 282 282 282 282 282 282 257 257 %GPVWT[2QQN%NGCPGT4GRNCEGOGPV2WOR/QVQTU 2GTOCPGPV5RNKV%CRCEKVQT±5YKVEJNGUU±5KPING2JCUG±&TKRRTQQH 0Q$CUG4KIKF$CUG±42/ Features: • Ball Bearings • CW Non-Reversible • Aluminum Adapter Bracket • 40˚C Ambient • 303 Stainless Steel Shaft • 60 Hz • Class B Insulation • “1081” Features Applications: Replacement motor for Arneson “Pool Sweep,” Polaris “Vac-Sweep” and Letro “Jet Vac” brand pool cleaners. HP RPM 3⁄4 3450 Notes: Service Volts Factor Amps 230/115 6.4/12.8 230/115 6.0/12.0 230/115 6.0/12.0 230/115 6.0/12.0 230/115 6.5/13.0 Service Factor 1.50 1.50 1.50 1.50 1.50 Frame 56CZ 56Y 56Y 56Y 56CZ 12. 303 Stainless steel shaft 222. Does not have Aluminum Adapter Bracket 246. B668 fits pump #LA01N manufactured March 1997 to present 247. B667 fits pump #LA01 manufactured March 1997 and prior 257. 60 Hz, only 282. 3450 RPM for 60 Hz and 2875 RPM for 50 Hz Pool Cleaner (Booster Pump ) motors are not included in the California Energy Commission Aplliance Regulations 2006 (Publication Number CEC 400-2006-002 REV 1) 219 Stock Number B625 B662 B663 B667 B668 Shaft Threaded Threaded Threaded Threaded Threaded Base None Rigid None Rigid None Mount Horizontal Horizontal Vertical Horizontal Horizontal Overload Protector Auto Auto Auto Auto Auto “C” Dim. 14.03 11.74 10.89 12.97 13.87 B662 & B663 Brand Polaris Arneson Arneson Letro Letro Notes 222 12 12 12,247 246 Important: 1. Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced. 2. The pool motors on this page are NOT equipped with a Safety Vacuum Release System (SVRS). SVRS helps prevent drowning due to body entrapment on underwater drains. In some pool configurations, if a person’s body covers the drain, the person can be trapped by suction. The SVRS turns off the pump if this occurs. Depending on your pool configuration, a SVRS may be required to meet local, state, and federal requirements. YYYCQUOKVJOQVQTUEQO PHONE: (866) 887-5216 %GPVWT[2WTGZ4GRNCEGOGPV2WOR/QVQTU Century® Purex Replacement Pump Motors *QTK\QPVCN±&TKRRTQQH±0Q$CUG±CPF*\±CPF 42/±VJTW*2 Features: Ball Bearings • 40°C Ambient • Service Factor 1.15 • Reversible • External Slinger Applications: Hydrotech (Purex) East Side “L” Series and “C” Series commercial pump. HP RPM Volts Single Phase • Capacitor Start 5 3450 230 230 Three Phase 5 7-1⁄2 10 15 Notes: 3450 3450 3450 3450 208-220/440 208-220/440 208-220/440 208-220/440 208-220/440 Hertz Full Load Amps Frame Insul Class 60 60 25.6 25.6 184TY 184TY B B 60 60 60 60 60 14.0-13.5/6.75 14.0-13.5/6.75 21.6-19.4/9.7 28.0-26.0/13.0 40.0-38.0/19.0 182TY 182TY 184TY 213TY 215TY F F F B F R236 Stock Number Overload “C” Dim. V214 V220 None None 15.7 15.8 77.0 77.0 153 152 R237 R236 R232 R338 R339 None None None None None 16.2 15.0 14.7 19.4 21.4 81.0 81.0 82.0 87.5 88.6 153 152 153 153 153 Efficiency Notes 152. Pump Series: L (threaded) 153. Pump Series: C (keyed) %GPVWTKQP5SWCTG(NCPIG2QQNCPF5RC2WOR/QVQTU 5SWKTTGN%CIG±6JTGG2JCUG±&TKRRTQQH±0Q$CUG±42/±VJTW*2 Features: Ball bearings • 60 Hz • 50°C Ambient • Class B Insulation • 303 Stainless Steel Threaded Shafts HP 1⁄2 3⁄4 1 1-1⁄2 2 3 RPM 3450 3450 3450 3450 3450 3450 Volts 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 Service Factor Amps@ 60 Hz 3.2-3.0/1.5 3.8-3.6/1.8 5.0-4.6/2.3 6.4-5.8/2.9 7.1-6.8/3.4 9.0-8.6/4.3 Service Factor 1.90 1.65 1.65 1.47 1.30 1.15 Frame 56Y 56Y 56Y 56Y 56Y 56Y Stock Number H491 H492 H635 H636 H637 H755 H491 Shaft Threaded Threaded Threaded Threaded Threaded Threaded Overload Protector None None None None None None “C” Dim. 12.2 12.8 13.2 13.4 13.9 13.9 Notes Important: 1. Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced. 2. The pool motors on this page are NOT equipped with a Safety Vacuum Release System (SVRS). SVRS helps prevent drowning due to body entrapment on underwater drains. In some pool configurations, if a person’s body covers the drain, the person can be trapped by suction. The SVRS turns off the pump if this occurs. Depending on your pool configuration, a SVRS may be required to meet local, state, and federal requirements. 226 www.pool-motors.com YYYCQUOKVJOQVQTUEQO Century® Pentair/Pac Fab Replacement Pump Motors %GPVWT[2GPVCKT2CE(CD4GRNCEGOGPV2WOR/QVQTU 5SWCTG(NCPIG±*QTK\QPVCN±&TKRRTQQH±0Q$CUG±*\ Features: Ball Bearings • 40°C Ambient • Class B Insulation B1000 HP RPM Single Phase PSC “1081” Volts Hertz Full Load Amps Service Factor Stock Number Frame Pac Fab Number “C” Dim. 5 3450 208-230 60 21.0-19.4 1.0 56Y B1000 35-5705 14.9 3 5 3450 3450 208-230/460 208-230/460 60 60 11.0-10.4/5.2 13.4-13.4/6.7 1.15 1.0 56Y 56Y H994 H995 35-5398 35-5704 13.9 14.9 Three Phase “1081” Notes %GPVWT[9CVGTYC[4GRNCEGOGPV2WOR/QVQTU &TKRRTQQH±*<±5KPING2JCUG±4KIKF$CUG±´&KCOGVGT±´5JCHV*GKIJV Features: • Ball Bearings • Auto Protector HP-SPL 1.0 ~.18 2.0 ~.25 3.0 ~.30 4.0 ~.50 5.0 ~.63 4.0 5.0 Notes: • 50˚C Ambient • Permanent Split Capacitor RPM 3450/1725 3450/1725 3450/1725 3450/1725 3450/1725 3450 3450 Volts 230 230 230 230 230 230 230 Full Load Amps 6.4/2.6 8.0/3.0 10.0/3.5 12.0/4.4 16.4/4.8 12.0 16.4 108. Two speed motor H Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov • 3/8-16 UNC-2A Threads Includes Slinger • Four Thru Bolts on a 5.812 Bolt Circle Frame 56Y 56Y 56Y 56Y 56Y 56Y 56Y Stock Number B232 H B233 H B234 H B235 H B236 H B237 B238 Insul. Class F F F F F B B “C” Dim. 10.87 11.87 12.12 13.37 13.37 12.62 13.37 B232 Waterway Number 3720621 3721021 3721421 3721621 3722021 3711821 3712021 Notes 108,$ 108,$ 108,$ 108,$ 108,$ Important: 1. Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced. 2. The pool motors on this page are NOT equipped with a Safety Vacuum Release System (SVRS). SVRS helps prevent drowning due to body entrapment on underwater drains. In some pool configurations, if a person’s body covers the drain, the person can be trapped by suction. The SVRS turns off the pump if this occurs. Depending on your pool configuration, a SVRS may be required to meet local, state, and federal requirements. YYYCQUOKVJOQVQTUEQO 0 227 PHONE: (866) 887-5216 %GPVWT[*C[YCTF0QTVJUVCT4GRNCEGOGPV2WOR/QVQTU Century® Hayward Northstar Replacement Pump Motors 0'/#%(CEG±&TKRRTQQH±0Q$CUG±*\±'PGTI['HHKEKGPV Features: • Ball Bearings • 50˚C Ambient • 303 Stainless Steel Shaft HP Full Rated RPM • Class B Insulation • 60 Hz • Low Noise • Switchless • E-Coated Main Frame for Superior Corrosion Resistance • Cool Running for Longer Winding Life Volts Full Load Amps Service Factor Frame Stock Number Industry Number “C” Dim. Notes 3/4 1 1-1/2 2 3 3450 3450 3450 3450 3450 208-230/115 208-230/115 208-230/115 208-230 208-230 6.0-5.5/11.0 8.5-7.8/15.6 11.0-10.2/20.4 13.0-11.8 20.6-19.0 1.85 1.85 1.60 1.35 1.60 56J 56J 56J 56J 56J SN1072 SN1102 SN1152 SN1202 SN1302 SP1607Z1BNSC SP1610Z1BNSC SP1615Z1BNSC SP1620Z1BNSC SP1630Z1BNSC 13.10 13.35 13.85 14.60 16.10 $ $ $ $ $ 1 1-1/2 2 2-1/2 3 3450 3450 3450 3450 3450 208-230/115 208-230/115 208-230/115 208-230 208-230 6.0-5.5/11.0 8.5-7.8/15.6 11.0-10.2/20.4 13.0-11.8 16.0-14.8 1.40 1.25 1.20 1.10 1.20 56J 56J 56J 56J 56J USN1102 USN1152 USN1202 USN1252 USN1302 Sp1607Z1MNSC SP1610Z1MNSC SP1615Z1MNSC SP1620Z1MNSC SP1625Z1MNSC 13.10 13.35 13.85 14.60 14.85 $ $ $ $ $ Uprated Important: 1. Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced. 2. The pool motors on this page are NOT equipped with a Safety Vacuum Release System (SVRS). SVRS helps prevent drowning due to body entrapment on underwater drains. In some pool configurations, if a person’s body covers the drain, the person can be trapped by suction. The SVRS turns off the pump if this occurs. Depending on your pool configuration, a SVRS may be required to meet local, state, and federal requirements. Century® Hayward TriStar Replacement Pump Motors %GPVWT[*C[YCTF6TK5VCT4GRNCEGOGPV2WOR/QVQTU Features: • 303 Stainless Steel Shaft • 60˚C Ambient • Automatic Protector • Ball Bearing • Capacitor Start/Capacitor Run • Class F Insulation • Energy Efficient • Open Drip Proof • Single Phase Single Speed - “1081” Capacitor Start/Capacitor Run - High Efficiency - Square Flange - Full Rate HP 1/2 3/4 1 1-1/2 2 RPM 3450 3450 3450 3450 3450 Volts 115/208-230 115/208-230 115/208-230 115/208-230 208-230 Amps 8.6/5.0-4.30 11.6/7.0-5.8 15.0/8.8-7.5 20.0/12.0-10.0 12.0-11.0 Service Factor 1.99 1.85 1.85 1.60 1.35 Frame 56Y 56Y 56Y 56Y 56Y Stock Number HSQ1052 HSQ1072 HSQ1102 HSQ1152 HSQ1202 Shaft Threaded Threaded Threaded Threaded Threaded Overload Protector Auto Auto Auto Auto Auto “C” Dim 12.8 13.1 13.4 13.8 14.1 Industry Number SP3205Z1BE SP3207Z1BE SP3210Z1BE SP3215Z1BE SP3220Z1BE Notes NEW! NEW! NEW! NEW! NEW! Important: 1. Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced. 2. The pool motors on this page are NOT equipped with a Safety Vacuum Release System (SVRS). SVRS helps prevent drowning due to body entrapment on underwater drains. In some pool configurations, if a person’s body covers the drain, the person can be trapped by suction. The SVRS turns off the pump if this occurs. Depending on your pool configuration, a SVRS may be required to meet local, state, and federal requirements. 228 www.pool-motors.com YYYCQUOKVJOQVQTUEQO Century® Close-Coupled Pump Motors %GPVWT[%NQUG%QWRNGF2WOR/QVQTU 6[RGU,/,2CPF6%<±6JTGG2JCUG±*QTK\QPVCN±&TKRRTQQH±4KIKF$CUG±CPF 42/±*\±VJTW*2 Features: Ball Bearings • 60 Hz • 40°C Ambient • Class B or F Insulation • External Slinger • Oversized, Locked Shaft End Bearing • Frame Suffix Letters TCZ Designate Century West Coast Pump Standard Motors E117 Applications: Commercial/industrial pump duty. Designed to meet a wide variety of applications for fluid transfer. HP 1 1-1⁄2 2 3 5 7-1⁄2 10 15 20 25 RPM 1800 3600 1800 3600 1800 3600 1800 3600 1800 3600 1800 3600 1800 3600 1800 3600 1800 3600 Notes: Volts 200-230/460 230/460 200-230/460 230/460 200-230/460 230/460 230/460 200-230/460 230/460 200-230/460 230/460 200-230/460 230/460 230/460 200-230/460 230/460 200-230/460 208-230/460 230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 Full Load Amps 3.5-3.8/1.9 3.8/1.9 4.5-4.2/2.1 4.2/2.1 5.0-5.6/2.8 5.6/2.8 5.6/2.8 6.2-5.6/2.8 5.3/2.65 6.2-6.4/3.2 6.4/3.2 9.0-8.6/4.3 8.6/4.3 8.6/4.3 9.1-8.8/4.4 8.8/4.4 9.2-8.6/4.3 13.4-13.2/6.6 13.4/6.7 14.2-13.0/6.5 15.5-15.0/7.5 15.5-15.0/7.5 15.5-15.0/7.5 21.8-20.0/10.0 22.0-19.0/9.5 20.5-17.2/8.6 22.0-21.0/10.5 22.0-21.0/10.5 28.2- 27.0/13.5 28.2- 27.0/13.5 29.0-27.0/13.5 30.0-26.0/13.0 26.0/13.0 34.0-26.0/13.0 42.0-38.0/19.0 42.0-38.0/19.0 42.0-38.0/19.0 46.0-39.6/19.8 46.0-39.6/19.8 55.0-51.0/25.5 55.0-51.0/25.5 55.0-51.0/25.5 58.0-53.6/26.8 58.0-53.6/26.8 67.0-61.0/30.5 67.0-61.0/30.5 67.0-61.0/30.5 1. Item to be discontinued when stock is depleted 6. 60/50 HZ 21. Terminal in bracket construction For mounting dimensions, see page 276 YYYCQUOKVJOQVQTUEQO Service Factor 1.15 1.25 1.15 1.25 1.15 1.25 1.25 1.15 1.25 1.15 1.25 1.15 1.25 1.25 1.15 1.25 1.15 1.15 1.25 1.15 1.15 1.15 1.15 1.15 1.25 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.25 1.25 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 Frame 143JM 143JP 143JM 143TCZ 145JM 145JP 145TCZ 145JM 145JP 145JM 145JP 145JM 145JP 145TCZ 182JM 182JP 182TCZ 182JM 182JP 182TCZ 184JM 184JP 184TCZ 184JM 184JP 184TCZ 213JM 213JP 213JM 213JP 213TCZ 215JM 215JP 215TCZ 215JM 215JP 215TCZ 254JM 254JP 254JM 254JP 254TCZ 256JM 256JP 256JM 256JP 256TCZ Stock Number E117 E118 E119 E149 E156 E157 E158 E159 E172 E174 E175 E177 E178 E179 E294 E295 E276 E296 E297 E279 E282M E283M E284M E285M E286M E287M E368 E369 E371M E372M E373M E374 E375 E376M E377 E378 E379 E482 E483 E485 E486 E487 E488 E489 E491 E492 E493 Insulation Class B B B B B B B B B B B B B B B F B B F B F F F F F F F F F F F F F F F F F F F F F F F F F F F “C” Dim. 14.40 17.85 14.87 17.85 14.87 17.85 17.85 15.40 17.85 15.40 17.85 15.40 17.85 17.85 16.88 19.94 18.02 17.12 20.18 19.52 14.97 19.11 18.02 16.97 20.78 20.78 17.43 21.31 18.43 22.31 21.49 17.43 21.31 20.47 19.93 23.81 22.59 20.88 20.88 23.60 26.48 26.48 23.60 26.48 23.60 26.48 26.48 Efficiency 84.0 81.5 86.5 86.5 84.0 81.5 81.5 82.5 82.5 81.5 81.5 84.0 84.0 84.0 85.5 85.5 84.0 86.5 86.5 80.0 82.5 85.5 85.5 82.0 85.5 87.5 87.5 87.5 86.5 86.5 88.5 88.5 88.5 88.5 88.5 88.5 88.5 88.5 88.5 90.2 90.2 90.2 87.5 87.5 90.2 90.2 90.2 Notes 6,21 6,21 6,21 1,6,21 6,21 6,21 1,6,21 6,21 6,21 6,21 6,21 6,21 6,21 1,6,21 6,21 6,21 1 6,21 6,21 1 1 1 1 1 1 1 Continues on next page 233 PHONE: (866) 887-5216 Continued from previous page %GPVWT[%NQUG%QWRNGF2WOR/QVQTU Century® Close-Coupled Pump Motors 6[RGU,/,2CPF6%<±6JTGG2JCUG±*QTK\QPVCN±&TKRRTQQH±4KIKF$CUGCPF 42/±*\±VJTW*2 Features: • Ball Bearings • Class B or F Insulation • 1.15 Service Factor • 60 Hz • 40°C Ambient • External Slinger • Oversized, Locked Shaft End Bearing • Frame Suffix Letters TCZ Designate Century West Coast Pump Standard Motors E572 Applications: Commercial/industrial pump duty. Designed to meet a wider variety of applications for fluid transfer. HP 30 RPM 1725 Volts 200-230/460 Full Load Amps 81.0-72.0/36.0 Frame 286JM Stock Number E572 Insulation Class F “C” Dim. 26.36 Efficiency 91.7 Notes 1 %GPVWT[%NQUG%QWRNGF2WOR/QVQTU 6JTGG2JCUG±6[RG,/±&TKRRTQQH±0'/#³%´(CEG±0Q$CUG±*\ Features: • Double Sealed Ball Bearings • 60/50 Hz Markings on Nameplate • Class B Insulation • External Shaft Slinger • Terminal In Bracket Construction. • 40°C Ambient • Oversized, Locked Shaft End Bearing E159RF Applications: Commercial pump duty. Designed to meet a wide variety of applications for fluid transfer. HP 1 2 Notes: RPM 1800 3600 Volts 200-230/460 200-230/460 Full Load Amps 3.5-3/8/1.9 6.2-5.6/2.8 Service Factor 1.15 1.15 Frame 143JM 145JM Stock Number E117RF E159RF “C” Dim. 14.4 15.4 Efficiency 84.0 84.0 Notes 1 1 1. Item to be discontinued when stock is depleted For mounting dimensions, see page 276 234 www.pool-motors.com YYYCQUOKVJOQVQTUEQO %GPVWT[+PFWUVTKCN%NQUG%QWRNGF2WOR/QVQTU Century® Industrial Close-Coupled Pump Motors 6[RGU,/,2CPF6%<±6JTGG2JCUG±*QTK\QPVCN±6'(%±4KIKF$CUG±CPF 42/±VJTW*2 Features: • • • • • Ball Bearings • 60 Hz • 40°C Ambient Class B or F Insulation • Service Factor 1.15 • External Slinger Oversized, Locked Shaft End Bearing Frame Suffix Letters JM and JP Designate NEMA Standard Motors Frame Suffix TCZ Designates Century West Coast Pump Standard Motors N211 Applications: Designed for the specific requirements of centrifugal pumps. HP 1 1-1⁄2 2 3 5 7-1⁄2 RPM 3600 1800 3600 1800 3600 1800 3600 1800 3600 1800 3600 1800 Notes: Volts 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 208-230/460 200-230/460 200-230/460 230/460 200-230/460 200-230/460 230/460 200-230/460 200-230/460 230/460 200-230/460 200-230/460 230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460 Full Load Amps 3.5-3.2/1.6 3.5-3.2/1.6 3.3-3.4/1.7 3.2-2.9/1.5 3.2-2.9/1.5 4.5-4.2/2.1 4.5-4.4/2.2 4.5-4.4/2.2 4.5-4.4/2.2 4.4-4.2/2.1 4.4-4.2/2.1 6.0-5.3/2.65 5.5-5.2/2.6 5.5-5.2/2.6 5.9-5.6/2.8 5.7-5.6/2.8 5.7-5.6/2.8 8.5-8.2/4.1 8.2-7.2/3.6 8.2-7.2/3.6 8.4/4.2 9.0-8.0/4.0 9.0-8.0/4.0 12.0/6.0 13.9-11.8/5.9 13.9-11.8/5.9 13.0/6.5 15.0-12.8/6.4 15.0-12.8/6.4 19.0/9.5 21.2-18.8/9.4 21.2-18.8/9.4 20.0/10.0 19.6/9.8 21.0-18.9/9.45 21.0-18.9/9.45 1. Item to be discontinued when stock is depleted 291. 208 Volt @ 1.0 Service Factor 333. Aluminum shell 361. 9 lead 362. 12 lead – Capability for Y Start-Delta Run 363. Double shielded bearings with no regreasing provisions For mounting dimensions, see page 276 YYYCQUOKVJOQVQTUEQO Frame 143JM 143JP 143JM 143JM 143JP 143JM 143JM 143JP 145JM 145JM 145JP 145JM 145JM 145JP 145JM 145JM 145JP 145JM 182JP 182JM 182TCZ 182JP 182JM 184TCZ 184JM 184JP 184TCZ 184JP 184JM 213JP 213JM 213JP 213JP 213TCZ 213JP 213JM Stock Number TCP71001 J TCP72001 J N149 TCP71026 J TCP72026 J N148 TCP71002 J TCP72002 J N161 TCP71027 J TCP72027 J N153 TCP71003 J TCP72003 J N163 TCP71028 J TCP72028 J N157 TCP72004 J TCP71004 J N251 TCP72029 J TCP71029 J N209 TCP71005 J TCP72005 J N211 TCP72030 J TCP71030 J N335 TCP71006 J TCP72006 J N329 N311 TCP72031 J TCP71031 J Insulation Class F F B F F B F F B F F B F F B F F B F F F F F F F F F F F F F F F F F F Cast Iron √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ Type E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ “C” Dim. 15.5 18.9 16.0 15.5 18.9 16.0 15.5 18.9 16.0 15.5 18.9 16.0 15.5 18.9 16.0 15.5 18.9 17.5 17.2 17.2 21.1 20.9 17.2 21.1 17.2 20.9 21.1 20.9 17.2 25.3 21.1 24.9 25.5 22.6 24.9 21.1 Efficiency Notes 75.5 361,363 75.5 361,363 New! New! 82.5 82.5 82.5 82.5 84.0 84.0 361,363 361,363 New! New! 361,363 361,363 New! New! 361,363 361,363 New! New! 84.0 84.0 361,363 361,363 New! New! 84.0 84.0 85.5 85.5 85.5 87.5 87.5 85.5 87.5 87.5 86.5 87.5 87.5 85.5 88.5 88.5 86.5 86.5 89.5 89.5 361,363 361,363 291 361,363 361,363 1,291 361,363 361,363 1,291 361,363 361,363 1,291 361,363 361,363 1 362,363 362,363 1 1,333 362,363 362,363 New! New! Continues on next page specially designed, and warranted be MotorsMotors specially designed, testedtested and warranted to be to Coronafor compatible are marked ona Free Corona-Free for compatible inverter duty areinverter markedduty on this page with Seecatalog pages for 28 and of thisEngineered catalog for® page with5aofJthis J Seethis page 4 and more29Speed Speed Engineered ® motors information. motorsmore information. 235 PHONE: (866) 887-5216 Continued from previous page %GPVWT[+PFWUVTKCN%NQUG%QWRNGF2WOR/QVQTU Century® Industrial Close-Coupled Pump Motors 6[RGU,/,2CPF6%<±6JTGG2JCUG±*QTK\QPVCN±6'(%±4KIKF$CUG±CPF 42/±VJTW*2 Features: • • • • • Ball Bearings • 60 Hz • 40°C Ambient Class B or F Insulation • Service Factor 1.15 • External Slinger Oversized, Locked Shaft End Bearing Frame Suffix Letters JM and JP Designate NEMA Standard Motors Frame Suffix TCZ Designates Century West Coast Pump Standard Motors N346 Applications: Designed for the specific requirements of centrifugal pumps. HP 10 15 20 25 RPM 3600 1800 3600 1800 3600 1800 3600 1800 Notes: Volts 230/460 230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460 230/460 200-230/460 200-230/460 230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460 200-230/460 200-230/460 Full Load Amps 26.0/13.0 25.0/12.5 29.4-24.0/12.0 29.4-24.0/12.0 28.3-25.2/12.6 28.3-25.2/12.6 40.0-35.0/17.6 40.0-35.0/17.6 36.0/18.0 36.0/18.0 40.9-36.6/18.3 40.9-36.6/18.3 46.0/23.0 53.2-47.0/23.5 53.2-47.0/23.5 48.0/24.0 56.7-49.2/24.6 56.7-49.2/24.6 60.0/30.0 60.0/30.0 66.1-59.0/29.5 66.1-59.0/29.5 67.9-62.0/31.0 67.9-62.0/31.0 1. Item to be discontinued when stock is depleted 291. 208 Volt @ 1.0 Service Factor 333. Aluminum shell 361. 9 lead 362. 12 lead – Capability for Y Start-Delta Run 363. Double shielded bearings with no regreasing provisions 364. Open bearings with regreasing provisions For mounting dimensions, see page 276 236 www.pool-motors.com Frame 215JP 215TCZ 215JM 215JP 215JP 215JM 254JM 254JP 254JM 254JP 254JM 254JP 256JP 256JM 256JP 256JP 256JP 256JM 284JM 284JP 284JM 284JP 284JM 284JP Stock Number N346 N313 TCP71007 TCP72007 TCP72032 TCP71032 TCP71008 TCP72008 N424 N419 TCP71033 TCP72033 N433 TCP71009 TCP72009 N435 TCP72034 TCP71034 N516 N523 TCP71010 TCP72010 TCP71035 TCP72035 J J J J J J J J J J J J J J J J Insulation Class F F F F F F F F F F F F F F F F F F F F F F F F Cast Iron √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ Type E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ E+ “C” Dim. 24.8 24.1 21.1 24.9 24.9 21.1 26.9 29.8 26.8 29.6 26.9 29.8 29.6 26.9 29.8 29.6 29.8 26.9 28.4 28.0 27.8 30.7 27.8 30.7 Efficiency Notes 84.0 1 85.5 333 89.5 361,2,363 89.5 362,363 89.5 362,363 89.5 362,363 90.2 362,364 90.2 362,364 89.5 1 89.5 1 91.0 362,364 91.0 362,364 87.5 1 90.2 362,364 90.2 362,364 91.0 1 91.0 362,364 91.0 362,364 87.5 1 87.5 1 91.0 362,364 91.0 362,364 92.4 362,364 92.4 362,364 Continues on next page Motors specially designed, tested and warranted to be for compatible dutytoare on MotorsCorona-Free specially designed, tested andinverter warranted bemarked CoronaJ See duty pagesare28marked and 29on of this page catalog fora page with ainverter Free this for compatible with ® motors information. J Seemore pageSpeed 4 and Engineered 5 of this catalog for more Speed Engineered ® motors information. YYYCQUOKVJOQVQTUEQO Continued from previous page Century® Industrial Close-Coupled Pump Motors %GPVWT[+PFWUVTKCN%NQUG%QWRNGF2WOR/QVQTU 6[RGU,/,2CPF6%<±6JTGG2JCUG±*QTK\QPVCN±6'(%±4KIKF$CUG±CPF 42/±VJTW*2 Features: • • • • • Ball Bearings • 60 Hz • 40°C Ambient Class B or F Insulation • Service Factor 1.15 • External Slinger Oversized, Locked Shaft End Bearing Frame Suffix Letters JM and JP Designate NEMA Standard Motors Frame Suffix TCZ Designates Century West Coast Pump Standard Motors N346 Applications: Designed for the specific requirements of centrifugal pumps. HP 30 40 50 Notes: RPM 3600 1800 3600 1800 3600 1800 Volts 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 Full Load Amps 79-70/35 79-70/35 80-73/37 80-73/37 105-96/48 105-96/48 106-96/48 106-96/48 131-120/60 131-120/60 134-118/59 134-118/59 362. 12 lead – Capability for Y Start-Delta Run 364. Open bearings with regreasing provisions For mounting dimensions, see page 276 YYYCQUOKVJOQVQTUEQO Frame 286JM 286JP 286JM 286JP 324JM 324JP 324JM 324JP 326JM 326JP 326JM 326JP Stock Insulation Number Class TCP71011 J F TCP72011 J F TCP71036 J F TCP72036 J F TCP71012 J F TCP72012 J F TCP71037 J F TCP72037 J F TCP71013 J F TCP72013 J F TCP71038 J F TCP72038 J F Cast Iron √ √ √ √ √ √ √ √ √ √ √ √ “C” Dim. 29.3 32.2 29.3 32.2 30.0 32.8 30.0 32.8 31.6 34.5 31.6 34.5 Efficiency 91.0 91.0 92.4 92.4 91.7 91.7 93.0 93.0 92.4 92.4 93.0 93.0 Notes 362,364 362,364 362,364 362,364 362,364 362,364 362,364 362,364 362,364 362,364 362,364 362,364 New! New! New! New! New! New! New! New! New! New! New! New! specially designed, and warranted to be MotorsMotors specially designed, tested tested and warranted to be CoronaCorona-Free for compatible arepage marked Free for compatible inverter duty are inverter marked duty on this withona pagesfor 28more and 29 of this catalog for with aJ ® J Seethis pagepage 4 and 5 of thisSee catalog Speed Engineered Speed Engineered ® motors information. motorsmore information. PHONE: (866) 887-5216 237 %GPVWT[%NQUG%QWRNGF2WOR/QVQTU Century® Close-Coupled Pump Motors 6[RGU,/,2CPF9%2±5KPING2JCUG±*QTK\QPVCN±&TKRRTQQH±4KIKF$CUG±CPF 42/±VJTW*2 Features: • • • • • Double Sealed Ball Bearings • 60 Hz • 40°C Ambient Class B Insulation • Service Factor 1.15 • Reversible External Slinger • Oversized, Locked Shaft End Bearing Frame Suffix Letters JM and JP Designate NEMA Standard Motors Frame Suffix TCZ Designates Century West Coast Pump Standard Motors P137 Applications: Designed for the specific requirements of centrifugal pumps. HP 1 1-1⁄2 2 3 5 7-1⁄2 10 Notes: RPM 1800 3600 1800 3600 1800 3600 1800 3600 1800 3600 1800 3600 Volts 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 230 230 200 115/230 115/230 230 230 200 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 Full Load Amps 15.0/7.5 15.0/7.5 16.0/8.0 16.0/8.0 15.0/7.5 18.0/9.0 19.2/9.6 19.2/9.6 20.4/10.2 25.0/12.5 25.0/12.5 13.4 13.4 15.6 34.0/17.0 34.0/17.0 20.0 22.0 24.0 26.0 26.0 26.0 25.0 25.0 25.0 39.0 39.0 39.0 32.0 32.0 32.0 42.0 42.0 42.0 Frame 143JM 143JP 143JM 143JP 145JM 145JP 145JM 145JP 182JM 182JM 182JP 182JM 182JP 182JM 182JM 184JM 184JM 184JP 184JM 184JM 184JP 184TCZ 213JM 213JP 213TCZ 213JM 213JP 213TCZ 215JM 215JP 215TCZ 215JM 215JP 215TCZ Stock Number P121 P126 P122 P127 P123 P128 P124 P129 P137 P228 P232 P130 P131 P132 P229 P230 P140 P135 P133 P231 P235 P212 P317 P324 P312 P318 P325 P311 P319 P326 P313 P320 P327 P321 Insulation Class B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B “C” Dim. 15.6 18.6 15.6 18.6 16.3 18.6 15.5 18.6 16.3 16.0 18.9 16.1 19.4 16.3 16.0 17.0 17.1 20.1 17.0 17.0 20.1 20.1 17.6 21.5 20.7 17.6 21.5 20.7 19.1 23.0 22.2 19.2 22.2 22.2 Efficiency 72.5 72.5 72.0 77.0 83.9 77.0 78.5 77.0 81.0 81.0 81.0 77.0 77.0 77.0 86.0 86.0 86.0 83.8 83.8 83.8 Notes 21 21 21 21 21 21 21 21 21 21 21 21 160 21 21 21. Terminal in bracket construction 160.Non-reversible, connected for CW facing end opposite shaft For mounting dimensions, see page 276 238 www.pool-motors.com YYYCQUOKVJOQVQTUEQO Speed Engineered® Motors Motors specially designed, tested and warranted to be Corona-Free for compatible inverter duty are marked in this catalog with a J. why Specify Speed engineered® inverter duty Motors? Variable frequency drives (VFDs), while offering advantages of greater control and energy savings to commercial and industrial motor users, can also cause premature winding failure in motors not designed specifically for inverter duty. Now A. O. Smith engineers have developed a solid solution...Speed Engineered® Inverter Duty Motor. Speed Engineered Inverter Duty Motors are specially designed and constructed to eliminate the destructive forces that can occur when motors are applied with drives. The Speed Engineered “Corona-Free” solution eliminates the causes of premature winding failure. All Speed Engineered motors meet or exceed NEMA MG1-31 performance standards, in addition to carrying A. O. Smith’s Speed Engineered warranty for inverter duty applications. The Causes of premature Motor failure Research we conducted identified why motors can fail when used with variable frequency drives under certain operating conditions. The results were published in a white paper, The Simple Truth About Motor/Drive Compatibility, which is available from A. O. Smith. Our findings revealed that “corona” as well as other potential hazards, can materialize and eventually damage motors applied with a drive. what is Corona? VFDs create high voltage pulses at the motor, especially when the motor and drive are separated by long power leads. Those high voltage pulses (or voltage spikes) develop voltage potential between adjacent conductors in the motor winding. When the voltage generated in the air between the conductors is high enough, the air breaks down. This breakdown is known as “corona.” The discharge that is created forms ozone, which causes the motor’s magnet wire insulation to disintegrate, causing premature failure. This phenomenon has been around for a long time and affects a limited number of earlier vintage motor/drive applications. But with drives becoming more sophisticated, inverter switching rates increasing and the percentage of motors operating with drives growing rapidly, incidents of downtime are also growing, and corona is now getting a lot of attention in the motor/drive industry. There are several techniques employed in the market to increase motor tolerance to corona. Although simpler and less costly, these practices are not always effective since corona is not cured...only bandaged. The only way to be sure the destructive efforts of corona will not compromise your motor/drive application is to eliminate corona altogether. This is easily accomplished by specifying A. O. Smith Speed Engineered motors on your next project. e-plus® Speed engineered® inverter duty Motor what Makes Corona-free Speed engineered® Motors Best for Motor-drive Compatibility? There are several solutions to the problem of motor insulation stress caused by inverters. Rather than just squelching the voltage overshoot which leads to corona, as mentioned earlier, the preferred method and the approach used by A. O. Smith is to design the motor to be corona free at expected peak voltage. We begin with a design premise of understanding the magnet wire corona inception voltage (CIV) and distribution of voltage in the motor. From that, our design approach becomes simply to: Choose a winding layout that minimizes the proximity voltage differences and reliably positions insulation materials to improve dielectrics above the threshold of corona… You may recognize this as the design approach for any motor, regardless if it is line operated or driven by an inverter. The difference is that with an inverter you must anticipate a much higher peak voltage and the rapid rise times of these potentially harmful pulses. PHONE: (866) 887-5216 Speed Engineered® Motors e-plus® 3 Speed engineered® inverter duty Motor At A. O. Smith, we build a motor able to withstand voltage peaks 3.5 times what is stated on the motor nameplate. Therefore we design additional insulation (tape, sleeving, phase paper, etc.) and strategically locate this added insulation in a manner that will yield the necessary protection against the high voltage pulses that may occur between magnet wire strands. This approach yields the desired design integrity. With the design for insulation and winding layout determined, the success of each motor now depends on placing the insulation properly during production. To provide final assurance for our customers, A. O. Smith uses a proprietary CIV tester that employs a unique procedure to detect and measure corona for each and every Speed Engineered motor we produce…before that motor leaves our factory! Because Motor/drive applications are so Varied, a. o. Smith offers Three distinct families of Speed engineered® Motors: e-plus® motors, the industry’s first high efficiency, energy-saving motor, meets 1997 EPACT standards. Now, E-Plus Motors also carry the protection of the Speed Engineered design and is warranted to offer the best performance available to inverter duty applications. www.pool-motors.com e-plus® 3 motors offer even heartier energy-efficient performance and savings, exceeding most utility conservation initiatives, in addition to meeting the 1997 EPACT standards. All E-Plus 3 motors are Speed Engineered rated for compatible inverter duty applications. Both E-Plus® and E-Plus® 3 motors are available in a variety of application configurations including: variable or constant torque loads, PWM, sensorless or sensored vector and with limited or broad speed ranges. Speed Engineered motors are rated for 4:1 speed ratio at constant torque or 6:1 at variable torque. Speed plus® Motor In addition to being corona free, A. O. Smith Speed plus® motors offer many additional benefits such as: Wide Speed Ranges to fit your application: • 20:1 at constant torque, standard • 1000:1 at constant torque with the addition of a blower kit Standard Features provide operational flexibility and dependability: • Totally-enclosed severe duty • All cast-iron construction • VPI corona-free Class F insulation system • F-1 mounted conduit box • Dual foot holes • Normally closed thermostats • Encoder provisions Highly Adaptable to address more specific process specifications: • Provisions for mounting a wide range of encoders: - Dynapar HS35 - Avtron M285 - Lakeshore SL56 - BEI HS 35 • 120-volt A/C blower kits • Drive end C-Face • Drive end D-Flange • Field convertible to F-2 conduit box location • Brake kits Commercial Pump Motor Cross Reference SINGLE-PHASE 230 (115) VOLT ODP HP RPM FRAME AOS 3 3 3 5 5 5 5 7.5 7.5 10 3600 3600 1800 3600 3600 3600 1800 3600 1800 3600 182JM 182JM 184JM 184JM 184Ty 184Ty 184JM 213JM 215JM 215JM P229 P130 P230 P231 V214 V220 P317 P318 P319 P320 MARATHON BALDOR EMERSON Z406 JML1406T Z407 Z408 JML1408T JML1409T GE STA-RITE BERkLEy ITT-MARLOW AURORA PENTAIR/PUREX DMH/DDH DMJ/DHJ 3B28EC-C2-1 CH50/CM50 LH50 Z409 Z410 Z411 Z412 JML1508T JML1509T JML1510T JML1511T CSPHk 3B32EC-C2-1 341A-3X4X9B-7.5-1 CSPHL THREE-PHASE 230/460 VOLT ODP HP RPM FRAME 3 3 5 5 5 5 7.5 7.5 7.5 10 10 10 15 15 15 20 20 25 3600 1800 3600 3600 3600 1800 3600 3600 1800 3600 3600 1800 3600 3600 1800 3600 1800 3600 145JM 182JM 182JM 182Ty 182Ty 184JM 184JM 184Ty 213JM 213JM 213Ty 215JM 215JM 215Ty 254JM 254JM 256JM 256JM AOS MARATHON e177 e294 e296 r237 r236 e282M e285M r232 e368 e371M r338 e374 e377 r339 e482 e485 e488 e491 M311 M313 M315 BALDOR EMERSON GE JMM3158T JMM3211T JMM3212T DJ3S1AM DJ3S2AM DJ5S1AM N846 N704 N705 STA-RITE BERkLEy ITT-MARLOW AURORA PENTAIR/PUREX DMH3/DHH3 DMJ3/DHJ3 3B28EC-C2-3 CHk50/CMk50 LHk50 M317 M319 JMM3218T JMM3219T DJ5S2AM DJ7S1AM N706 N707 M321 M323 JMM3311T JMM3312T DJ7S2AM DJ10S1AM N708 N709 M325 M327 JMM3313T JMM3314T DJ10S2AM DJ15S1AM N710 N711 JMM2514T JMM2515T JMM2516T DJ15S2AM DJ20S1AM DJ20S2AM DJ25S1AM N712 N713 N714 N715 CSPHk3 3B32EC-C2-3 CMk75/CHk75 M329 M330 M331 M332 341A-3X4X9B-7.5-3 CSPHL3 CSPHM3 CSPHN3 L L L L L L L L SERIES SERIES SERIES SERIES SERIES SERIES SERIES SERIES CMk100/CHk100 341A-3X4X9B-10-3 CMk150/CHk150 341A-3X4X9B-15-3 341A-4X5X11-20-3 THREE-PHASE 208-230/460 VOLT TEFC 0 HP RPM FRAME AOS MARATHON BALDOR EMERSON GE 3 3 5 5 7.5 7.5 10 10 15 15 20 20 25 25 3600 1800 3600 1800 3600 1800 3600 1800 3600 1800 3600 1800 3600 1800 182JM 182JM 184JM 184JM 213JM 213JM 215JM 215JM 254JM 254JM 256JM 256JM 284JM 284JM tCP71004 tCP71029 tCP71005 tCP71030 tCP71006 tCP71031 tCP71007 tCP71032 tCP71008 tCP71033 tCP71009 tCP71034 tCP71010 tCP71035 M405 M406 M407 M408 M409 M410 M411 M412 M413 M420 M414 M421 JMM3610T JMM3611T JMM3613T JMM3615T JMM3709T JMM3710T JMM3711T JMM3714T JMM2394T JMM2333T JMM4106T JMM2334T JMM4107T JMM4103T UJ3S1AM UJ3S2AM UJ5S1AM UJ5S2AM UJ7S1AM UJ7S2AM UJ10S1AM UJ10S2AM UJ15S1AM UJ15S2AM UJ20S1AM UJ20S2AM UJ25S1AM UJ25S2AM N735 N737 N738 N739 N740 N741 N742 N743 N744 N745 N746 N747 N748 N749 STA-RITE BERkLEy ITT MARLOW AURORA PENTAIR PUREX M08311 M10490 S34562 PHONE: (866) 887-5216 Index of Footnotes No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 Footnote Description Itemtobediscontinuedwhenstockisdepleted BallBearing SpecialOEMreplacementmotor Suppliedwithleadandplugassembly $Energyefficienttwovaluecapacitorstart, capacitorrunmotor 60/50HZ Resilientmountingringsincluded NemadesignA Reversingplug Reversible.Quickconnectterminals CFlangekitavailable 303Stainlesssteelshaft Sixleadmotorsuitableforpartwindingstart Totallyenclosednon-ventilated 56HZ=7/8keyedX25/16shaft $E-Plusenergyefficientmotorcomplyingwith EPact Suitablefor208volts@1.0servicefactor Includes1/4-5/16bushing C&Dflangekitavailable $Energyefficientcapacitorstart,capacitorrun Conservationistmotor Terminalinbracketconstruction 3thrubolts,4.42dia.Boltcircle Suitablefor200/400voltand50HZ Mountingaccessoriespackagedwithmotor Hashexmountinghubonbothendsforcradlebase mounting Extendedthrubolts,shaftendonly Extendedthrubolts,bothends Blowerkitadaptable,TEFC 60degreeCambient 56,140framecombinationbase(12mountingholes) 40degreeCambient 24”leads(minimum) Rollerbearings Rigidbase Quickconnectdesignbracket Lugmount Leadreversible,noplug Includesconduitbox,mountingscrews,gasket, shippeddetached Gasketedconduitbox Fourmountingholesinshell Extendedthrubolts,leadendonly Eightmountingholesinshell ClassAinsulation CCWLErotationonly Capacitorstart Adapt-a-Lugmotors(Seelugs) 3/8diametershaft 1.0Servicefactorat50HZ 1.0Servicefactor Usewith5MFD/370V@230volt,7.5MFD/370volt @208volt Usedownsize250FrameC&Dflangekits(D-flange kitpart#800289-01,C-flangekitpart#800288-01 Two-speedconnection:white-common,red-low, black-high Twelvelead,wyedelta Triplebuildwireforgreaterhighvoltageinsulation Terminalboard TEAOgasketedconduitbox-3/4extendedthrubolts TappedholesforColemanmount Suppliedwithresilientmountingrings Suitableforusewithlowambientspeedcontrol Stockno.1218Aadapterandringssuppliedforbase mounting Startcapacitorinside SplitPhase Speckpumpreplacementmotor Spadeconnector Sixlead,WyeDelta Sealedswitchdesign Rewireforsecondspeed PSCmotor Pinholeinshaft PermanentSplitCapacitor www.pool-motors.com No. Footnote Description 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 Nohubsoneitherend Nobrakekitavailable Nobase NemadesignAavailableuntilcurrentstockis depleted,thenwillbecomeNemadesignB Mountingringsnotincluded Motorsshippedwiththruboltsoutshaftend-See photosabove.Maybereversedforvertical applications MolexTerminalPlug Moderatestarttorque Leadlessdesign Largecapacitor/terminalboxconstruction Includesbase Horizontalmountonly Extendedthrubolts-5/8 Energyefficientwithsplitphasestart,capacitorrun withmountedcapacitor Energyefficient$-capacitorstart/run Cordandplugwithpullchain ClassFinsulation C&Dflangekitadaptable,ODP,EMISeries850000 60”leads 50degreeCambient 5/8extendedthrubolts,17/8shaftlengthand1/2 shaftdia. 48/56FR=1/2X11/2shaftwith5/8shaftadapter -48/56slotted3heightbase 36”cord 30”leads(minimum) 3/8flattedshaft 2thrubolts,4.42dia.Boltcircle 182Tand184Tmountingholes,4.5shaftheight 1/2hubonshaftendandslinger 1/2extendedthrubolts,shaftend 1/2diametershaft 1.5servicefactor 1.15servicefactor WhenusingU.E.base,add(2)1221Aadapterrings toEACHmountingring Verticalmount Usewith1805Aor2099Abracket Use4MFD/370Vcapacitor Uprated-lowservicefactor Two-speedmotor Twosidebosses Twomountingholesineachbracketfora9andfora 10.18boltcircle TotallyenclosedversionofOCC1026 Totallyenclosedfancooled Totallyenclosed ThreadedshaftwithAcmethreads Thismotorisratedforoperationon60or50HZ power,fullloadampslistedat60HZ Temperaturesensitivethermostatwithtwoleadsfor connectiontoexternalcontrol TEAOgasketedconduitbox TEAO SuitablereplacementforAaon Suitablereplacementfor1/12HPand1/10HP Stronger3/4HPrequiredforsomeapplications Stocknumber91hasastainlesssteelshaftand20 leadsforuseonicemachines Stockno.684BAdimensionwas4,motorsbuilt after4/98willhaveaBAdim.Of33/4 Stainlesssteelshaft Specialpivotstylerigidbase Specialmountingbracket SpecialHaywardreplacementforSP-1515-Z24-EBK, EBKC,C48M2A16A1 SpecialDoughboyreplacement,lessbase,40degree Cambient,Al.Windings SpecialCanadianmotor,externalrelayisrequired Sleevebearing Singleflatonshaft Shaftsleeveandkeysuppliedfor5/8diameter ShaftN-W=2.50withtwoflats.04deep,2.16long, 90degreesapart ShaftN-W=2.50with5/8diameterandkeyway No. Footnote Description 135 136 137 138 139 140 141 142 143 Shafthasnoflat Shaftdim.=9X1/2X81/2 Shaftdim.=8-1/2X1/2X91/8 Shaftdim.=9X1/2X7-1/2 Shaftdim.=10-3/4X1/2X10-15/16 Shaftdiameteris1/2,N=2 Shaftdiameteris1/2,N=1.94with.04deepflat Servicefactoramps Servicefactor1.00underinverterpower(sinewave poweronly60HZ)asshownabove 144 Servicefactor1.0usedonnon-sinusoidalvoltage waveforms 145 Runcapacitormountedonmotorshell 146 Roundframe 147 Resilientmountingringsincludedforrefrigeration applications 148 ReplacementforCarrierHD52AK652 149 Reconnectforseparatespeeds 150 Rated50/60HZ 151 Quickconnectdesignbracket,autooverloadprotector 152 Pumpseries:L 153 Pumpseries:C 154 PreviousstocknumberswithXsuffixarethesame ascurrentmodels 155 PolarisVac-sweep(shaftadapternotrequired) 156 Openshaftendbracket 157 Openconstruction 158 Openmotorconstruction,overloadprotector mountedat12O’clock 159 Opendripproof 160 Non-reversible,connectedforCWfacingend oppositeshaft 161 Nosidebosses 162 Noresilientrings.12leadswithMolexterminal 163 Nokeyway,doubleflat 164 Nohubonleadendendframe 165 Noextendedthrubolts 166 Noconduitbox 167 NewQuad-Plusmodel-removablebase(RMOV), verticalshaftupordownandsteelframe construction 168 Nema42/48C-face,1/2diameterkeyedshaft,1 5/16long 169 MotorsproducedbeforeJune,2003areE+ 170 MotorsmayberewiredtorunCW 171 Motoristhermallyprotected 172 Motoriscentermounted 173 Motorhas4studs 174 Motorfitstorquemount 175 Molexleadconnectionplug,12longleads 176 Moistureproofstator 177 Meetstherequirementsoftheenergypolicyactof 1992 178 Lowspeed1/2HP 179 Lowamps 180 LowampreplacementforavarietyofOEMSpecial andSPL5horsepowerrequirements 181 Looseleadconstruction 182 Lockedbearingondriveend 183 Liftingprovisions 184 Leadexitisonshaftend 185 ItemswithUniversalandA.O.Smithstocknumbers andsamespecificationsareidentical.TheA.O. Smithstocknumberswillbediscontinuedwhen stockisdepleted. 186 Itemtobediscontinuedwhenstockisdepleted. DiscontinueditemsavailableformGraham Transmission,Inc. 187 Incudesmountingbracketandshaftbushing 188 Includessplitbushingandkeyfor5/8shafts.3thru boltsona4.42dia.Boltcircle 189 Includessplitbushingandkeyfor5/8shafts 190 Includespilotlightdetector 191 Includesmountingbracket 192 Includesfour(4)10-32mountingholes 193 IncludesformerGEbrandequipment 194 Includesfanblade 195 Includes6’cordandswitch 196 Includes5/8adapterandkey Index of Footnotes No. Footnote Description 197 198 199 200 201 202 203 204 205 206 207 208 209 Includes2speedplug Impedanceprotected Horizontalrigidbase Hasspecial3.15boltcircle Fourstudsona5.15diameterboltcircle Formotoronly,useJ375 Formotoronly,useJ373 Formotoronly,useJ372 Formotoronly,useJ370 MasterFitmotor,foradditionalinformation seepage73 Fleximountarmsarenotattachedtomotor- bellybandwitharmsispackedwithmotor Fitsmost38GSSeries FB1106&FR1106alsoreplacesmotorusedon KramerTrentonunitsDD661,DD791(useFR1106 forverticalapplications FB1076/FR1076alsoreplacesKramerTrenton045004andUniversalHF3W0R8K,HF3W052N FB1056isthesameasFB1056X FB1056alsoreplacesDunhamBushmotorMTR226 Farmduty-gasketedconduitboxandcapacitor cover F2Assembly Eyeletterminalsontheleads Equippedwithrotationswitchforeasy reversibility Equippedwithprovisionsformounting4X4 conduitbox Energyefficient$-splitphasestart/capacitorrun Dualvoltageconnection:black-common,white-120 volt,red-240volt Dripcoverkitavailable(Part#103017-03) Doesnothaveconduitbox Doesnothavealuminumadapterbracket DirectreplacementforSurgemilkpumps,Babson motor#27732,requires30MFD/370VACcapacitor, separately-notsupplied DirectreplacementforGEWB26X24,WB26X40and WB26X45 Directreplacementforgafferandsattlerand dynavent DirectreplacementforCarlin27490S DirectreplacementforBeckett21805U CWSEnotreversible CWLErotation CSAapprovablenotapplicable Includes8/32mountingstuds Closedmainframe,21/2rings,14leads ClassBinsulation Centurynameplatedproduct CenturionIImotorsareswitchless.Designedina48 frameshelldiameterthatis.80inchessmallerthan the56frameCenturionandCenturionSEdesigns CCWrotationfacingoppositeshaftend CarrierreplacementforHD60FK651,special BAdim.=4.12 CarrierreplacementforHD60FK652,special BAdim.=4.12 Capacitorattached Capacitorandrainshieldincluded Capacitorandrainshieldincluded BXconnector Base&clampincluded,9.44ringtoringdimension Ball/sleeveconstruction BallBearing,formotoronly,useJ320 B668fitspump#LA01NmanufacturedMarch,1997 topresent B667fitspump#LA01manufacturedMarch,1997 andprior B14mount ArnesonPoolSweep Also1/10Hpat1050RPM All1HPand11/2HPmotorsuppliedwith conversionkitallowingmotortobeusedinmost56 frameapplications 8.5footconductorcordandplugwithstrainrelief attached 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 No. Footnote Description 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 5/8”dia.keyedandflattedshaft6”long 8.26”boltcircle,.28”diametermountingholes 70degreeCambient 7-3/8”diameterboltcircle 60HZonly 6MFD/370V@230V,8MFD/370V@280V 575voltbrakecoil 56Z=1/2”flattedshaft 56Z=1/2”flatX1-1/2”shaft,31/2shaftheight 56Z=1/2”’flatX1.62”shaft,with56FR.Base 53”leads 50/60HZ1.4/1.7Amps 50leads,21/2resilientrings 50HZ,190/380volt,925RPM 50HZ-1.00servicefactor,190/380volt 50HZ 50cycleonly 5/8keyedshaftwithflat 5/8keyedshaft 5/16diametershaft 48Z=5/8dia.X2shaft,with3height 48Z=1/2flatX1.88shaft,with48FRbase 48-56framemounting-3shaftheight,sleeveand keyadapterto5/8shaft 48-56framemounting-31/2shaftheight,sleeve andkeyadapterto5/8shaft 47”leads 40”leads 4thruboltsand4dummystudsona5.16diameter boltcircle 4in1multi-horsepowermotor,replaces1/3,1/4, 1/5,1/6HP 36”leads 3450RPMfor60HZand2875RPMfor50HZ 31”lineleads,5capacitorleads 31”leads(minimum) 3/8-16,Lefthandthreads,CWPErotation 3.5shaftheight 3shaftheight 26”leads(minimum) 12-1/4”leads 230Vand208Vconnection,sametorque 208Volt@1.0Servicefactor 20”leads 9”leads 2.6”shaftheight 2shaftlengthand1/2”shaftdiameter,sleeveand keyadapterto5/8” 2-Speedshippedlesshi-loswitchforremotecontrol 184Tbase,4.5shaftheight 2-1/4X7/8keyedshaft 15”leads 115volttapoffmainwindingtopowergeardrive unit 11”leads(minimum) 11”leads 10.19boltcircle,.28diametermountingholes 10-1/2”leads 1/4-20UNC-2Btappedholesona4.67diameterbolt circle 1/2”shaft,sleeveandkeyadapterto5/8shaft 1/2”hubonshaftendframewithslinger.Grommet onleadexits. 1/2”extendedthrubolts 1/2”doubleflatshaft,21/2rings 1/2”dia.Shaft-singleflat 1.40Servicefactor 1”extendedthruboltseachend 1”extendedthrubolts 1-7/8”shaftend,1/2leadendextendedthrubolts 1-5/8”shaftend,7/8leadendextendedthrubolts 1-5/8”extendedthrubolts 1-1/2”extendedthrubolts CDimensionisthetotallengthincludingshaft 56Y=7/8”diameterkeyedshaft,2.25long Bohn/HeatcraftmountinghardwareandOEMfan bladeincluded. MechanicallyReversible No. Footnote Description 323 Kitincludesthreefans:4”blade,5.50”dia.,CCW rot.,5”blade,5.50”dia.CCWrot.5”blade,4.00” dia.CWrot. 324 Motorfitstonguemount 325 Canbemountedverticallybyadding10301702 cover(soldseparately) 326 CastIron 327 CarrierSensorAssembly(50HJ401484)not included 328 SquareFrame 329 Forusewithadjustablebase 330 56Z=1/2”shaftwithflat,1.62”long 331 Cannotbemountedwithrings–ringtoring dimensionisbodylength 332 Noconnectorplug,leadsonly 333 Aluminumshell 334 Reversible 335 EnergyEfficient,capstart,lowspeed,PSChigh speed 336 Capacitorstart,lowspeed,PSChighspeed 337 Connectiondiagrammaybe#23,old#125ornew #125dependingondateofmanufacture 338 Tacoreplacement 339 Armstrongreplacement 340 BellandGossetreplacement 341 1/2”dia.-shaft2.25”long 342 5/8”dia.-shaft2.37”long 343 5/8”keyedshaft-3.88”long 344 5/8”keyedshaft-2.31”long 345 Rigidbase-wallmount 346 65degreeCambient 347 3thrubolts,4.62dia,boltcircle 348 6-1/2”diameterbody 349 2-1/4”mountingrings 350 Conduitconnectorincluded 351 eModequippedmotor 352 Pentair,almondpaint,directreplacementmotor 353 56Z=5/8”diameterkeyedshaft,2-1/8”long 354 56Z=7/8”diameterkeyedshaft,2-1/4”long 355 Base805C290H04andClamps165B674A01 available 356 3rearmountingholes 357 4thrubolts,4.42”dia.boltcircle 358 4thrubolts,on4.62dia.boltcircle 359 4studswithspacerandnutona3.87diameterbolt circle 360 4thruboltsona5.15dia.boltcircle 361 9leads 362 12lead–capabilityforYStart-DeltaRun 363 Doubleshieldedbearingswithnoregreasing provisions 364 Openbearingswithregreasingprovisions 365 3leads 366 6leads 367 12leads 368 InverterDuty 369 AutomaticProtector 370 48”leads 371 Removable56Hrigidbase 372 VCM™Feature(VoltageChangeModule) PHONE: (866) 887-5216 Premium Efficiency Two-Speed Pool and Spa Motors with Integrated Timer 2 t! uc d o r P New A premium efficiency motor in the Centurion motor family. Features: • • • • • Integrated Timer Interface Timer Mode Adjustable Contrast Manual Mode Over Current Protection • • • • • Battery Backup - Program Saver LCD Display with Backlight Ball Bearing Class B Insulation 50˚C Ambient • • • • • High Efficiency High and Low Speed Open Dripproof Rotation: CCW Pump End Single Phase 303 Stainless Steel Shaft Two-Speed - “1081” Capacitor Run Low Speed, PSC High Speed, Sq. Flange HP RPM Volts Service Factor 3/4 ~ .10 3450/1725 230 1.67 1 ~ .13 3450/1725 230 1.65 3450/1725 230 1.30 3/4 ~ .10 1 1/2 ~ .19 2 ~ .25 3450/1725 3450/1725 115 230 1.67 1.47 ServiceFactor Amps Stock Number Total HP Percent EnergySavings* Yearly$ Savings** 6.0/1.0 B2980T 1.25 58% $633.32 7.4/1.4 B2982T 1.65 51% $625.60 11.0/1.8 B2984T 12.4/2.2 10.0/1.6 B2981T B2983T 1.25 2.21 2.60 55% 51% 53% $606.29 $687.79 $634.53 *Savings over the equivalent single speed motor. **Calculated @ $.23 per Kilowatt hour, pumping same amount of water as a single speed motor, eight hours per day. See the Energy Savings Calculator at: www.aosmithmotors.com The reasons a 2GreenTM premium-efficiency replacement motor can offer such impressive savings are numerous including: • An integrated timer interface allows for easier installation and operation of a two-speed replacement motor. The all-in-one design reduces installation time and expense with no additional wiring required. • A run capacitor used on both high and low speeds improves electromagnetic balance increasing the power factor and watts efficiency resulting in lower amps and lower operating cost. • The amount of horsepower required to move the water through the pipes drops much more quickly than the speed. While it may take one horsepower to move the water through the pipes on high speed it only takes 1/8 horsepower to move one half as much water through those same pipes on low speed. Even when run on low speed twice as long to pump the same amount of water as on high speed, the lower horsepower results in significant energy savings. The Pool Motor... S with a built in afety Vacuum Release System The New Standard in Pool and Spa Motors HP Listed to the ASME A112.19.17 SVRS standard for 1 1 1-1/2 2 3 1 1-1/2 2 3 3/4 1 1-1/2 2 3 1 1 1-1/2 2 2 3 3/4 Voltage 115/230 115/230 115/230 208-230 208-230 230/115 230/115 230 230 115/230 115/230 115/230 230 230 230/115 230/115 230/115 230 230 208-230 115/230 RPM Frame Service Service Size Factor Factor Amps Model Number Mounting 3450 56J1.1015.0/7.5USTG1102A NEMA-C 3450 56J1.5018.6/9.3STG1102A NEMA-C 3450 56J1.00 18.6/9.3 USTG1152ANEMA-C 3450 56J1.32 12.6/11.4 STG1202ANEMA-C 3450 56J1.15 14.5/13.8 STG1302ANEMA-C 3450 56J1.40 7.2/14.4 BG128A NEMA-C 3450 56J1.30 9.2/18.4 BG129A NEMA-C 3450 56J1.20 10.5 BG130A NEMA-C 3450 56J1.15 14.1 BG131A NEMA-C 3450 48Y1.27 11.8/5.9 USQG1072ASQ-FLANGE 3450 48Y1.25 14.8/7.4 USQG1102ASQ-FLANGE 3450 48Y1.10 19.2/9.6 USQG1152ASQ-FLANGE 3450 48Y1.30 11.2 SQG1202A SQ-FLANGE 3450 56Y1.15 15.4 SQG1302A SQ-FLANGE 3450 56Y1.25 7.1/14.2 BG853A SQ-FLANGE 3450 56Y1.65 8.0/16.0 BG848A SQ-FLANGE 3450 56Y1.10 8.0/16.0 BG854A SQ-FLANGE 3450 56Y1.10 10.0 BG855A SQ-FLANGE 3450 56Y1.30 11.5 BG748A SQ-FLANGE 3450 56Y1.15 15.0-13.6 BG2844A SQ-FLANGE 345056CZ1.50 12.8/6.4 BE625* SPECIAL A Deeper Pool of Resources suction lift applications. 60HZ, Ball Bearing, Stainless Steel Shaft, *Polaris Pool Cleaner Your Authorized Distributor is: NOW AVAILABLE! FAX OR PHONE YOUR ORDER TODAY! A DIVISION OF A. O. SMITH CORPORATION Distribution Services 1325 Heil Quaker Blvd. LaVergne, TN 37086 Phone: (866) 887-5216 Fax: (800) 468-2062 www.pool-motors.com Copyright © 2011 A. O. Smith Corporation Bulletin #1081-1082 Divisional Headquarters A. O. Smith Electrical Products Company 531 North Fourth Street Tipp City, OH 45371 2/11