patient dose qa

Transcription

patient dose qa
2-in-1
PATIENT DOSE QA
with QuickCheckTM
iba-dosimetry.com
Not enough
time for quality
patient QA?
QuickCheck™ with
3D Patient Dose QA is
your efficiency choice for
standard and complex
treatment verification!
YOUR 2-IN-1 PLAN VERIFICATION SOLUTION
Verify your TPS plan
QuickCheck™
Calculation Efficiency:
Highest QA
Efficiency
e.g. for
standard
cases
Save TPS time as no hybrid/phantom
plan is required
ULTIMATE QA EFFICIENCY:
TPS
Save measurement time and speed
QuickCheck™
ULTIMATE 3D ACCURACY: COMPASS 3D
Automatic Verification
Understand the impact of dose discrepancies
TPS
Check
up verification
Rapid computation times: 7 beam IMRT
Option 1
TPS
in less than 1 min & VMAT Arc in 2-3 min
Calculation
TPS Check
Compass
reconstructed
Calculation Accuracy:
ull TPS class Collapsed Cone
F
re-calculation with Monte Carlo
linac model
3D Dose
Difference/
Gamma
(local & global)
ore powerful than simple MU checks
M
ull 3D dose calculation on real
F
patient CT
3D dose reconstruction & analysis in COMPASS
Automatic QuickCheck evaluation gives you an instant “pass” or “evaluate”
TPS Plan
Verification Efficiency:
Verify the plan in the patient anatomy:
Fully automized fluence analysis in seconds
3D dose calculation reconstruction on real patient CT
I nstant QA results display with “pass”
or “evaluate”
Verify your entire treatment chain
igh-resolution ionization chamber
H
detectors with 50ms sampling time
G
amma or Dose difference displayed in
just one look
Avoid vendor dependencies by
A
utomatic evaluation based on your
in-house protocols
Measurement
Highest QA
Safety e.g.
for complex
cases
Measurement Efficiency
Head & Neck case
Fast & easy detector setup with
auto alignment
Use your measured data for a fast
QuickCheck evaluation or a full
3D dose reconstruction on the
patient CT
A
utomatic PTV and OAR evaluation
Verification Accuracy:
analyzing linac log-files
Delivery Check
Automatic evaluation of the PTV and OAR evaluation
3
D dose reconstruction on real patient CT
A
utomatic email notification
Measurement Accuracy
Option 2
Optional Step
Gantry based 360°
measurements optimized
for rotational cases
QA Workflow Efficiency – save 20 min
“ The COMPASS system provides fast and
reliable 3D dose verification for clinical IMRT
QA. The COMPASS QA process does not
require phantom plans. Therefore, it allows
a simple QA workflow.”
Conclusion of publication: Nakaguchi Y et al.: (2014) Validation
of a quick three-dimensional dose verification system for
pre-treatment IMRT QA. Radiological Physics and Technology,
8(1), 73-80..
Segment/control point wise analysis verifiy the effect of segment errors on the total treatment accuracy
Comparison of QA times between COMPASS,
3DVH, and EDR2 (Film) for 10 clinical IMRT/
VMAT plans
Comprehensive reporting: Easy
protocol template setup according
to your needs
Maximize Efficiency
Better Outcome
Minimize Errors
A
uto email notifications
F
lexible plan import with full
DICOM conformance
A
ll patient data centralized in
MS SQL Server database
F
ast template-based
installation
R
apid computation times:
7 beam IMRT in less than
1 min & VMAT Arc in 2-3 min
in a nutshell
ass/Fail based on your
P
protocol
Verify the source of deviations
and understand the clinical
relevance
Replace human subjectivity
TPS class collapsed cone
algorithm
ltimate QA flexibility for
U
simple as well as complex
cases
Comprehensive reporting
uture integration in
F
global QA platform*
Over 55 COMPASS Publications for Clinical & Scientific Background!
Find publication list on the QuickCheck website.
Your peers opinion:
“The new QuickCheck enables an assessment
to be automatically performed, for all cases,
immediately after the measurement terminates.
Customised tolerances for the QuickCheck
assessment can be loaded on import of the plan
to identify set-up issues, or unusual deviations from
typical results. This helps to quickly identify problem
cases so they can be dealt with early.”
Kevin Brownsword, Medical Physicist
Castle Hill Hospital, United Kingdom
“The system is the best 3D solution out there. You
can get 3D on patient anatomy in only 2 clicks.”
Mathias Dierl, Head of Medical Physicists
Clinical Center Bayreuth, Germany
Europe, Middle East, Africa | +49 9128 6070
North America, Latin America | +1 901 386 2242
Asia Pacific | +86 10 8080 9288
dosimetry-info@iba-group.com
iba-dosimetry.com
*Integration of QuickCheck / Compass in myQA is
a work in progress. Currently not available for sale.
“We are excited about many of the changes
including a more efficient beam modeling process
and significantly faster dose calculation.”
Ryan Rivest, PhD, Medical Physicist
Cancer Care, Canada
“The system is such an exciting tool to use which
provides us crucial calculation time saving and
therefore much faster QA workflow.”
Ghirmay Kidane, PhD, Consultant Radiotherapy Physicist
BHR Hospitals, United Kingdom
2-in-1 Patient Dose QA with QuickCheck_RT-BR-E_Rev.1 | © IBA 2016 | All rights reserved | Manufacturer: IBA Dosimetry GmbH | Technical specifications and product features are subject to change without prior notice.