Home Inspection Report 1704 Stone Slate Road, Bedrock, AL 12345 Inspection Date: Thursday, October 1, 2015 Prepared For: Fred & Wilma Flintstone Prepared By: Majestic Home Inspectors 1204 Hanna Ave Maryville, TN 37804 (865) 264-0943 steve@majestichomeinspectors.com Report Number: 1000tn09222015 Inspector: Steve Mangham 1704 Stone Slate Road Bedrock, AL 12345 Page 2 Report Summary Items Not Operating Concerns Roof: Some nail popping has occurred, recommend repair. Roof: Some shingles are heaving/lifting up, recommend repair Front Porch: Steps - Safety/Trip Hazard - uneven tread/not level, recommend repairBasement: Firewall Door - No self closing mechanism, recommend installing self closing mechanism Carbon Monoxide Detectors: None installed. With fuel heat, carbon monoxide detectors could be installed to detect for carbon monoxide Master Bath: Toilet bowl is loose recommend repair Flashing has pulled away from the chimney - recommend repair Master Bath: Toilet bowl is loose recommend repair Potential Safety Hazards Front Porch: Steps - Safety/Trip Hazard - uneven tread/not level, recommend repair Garage: Source of ignition less than 18" of floor, Safety Hazard, Recommend raising ignition source above 18" Water Heater Wiring: Safety Hazard: Wiring Exposed, recommend install wire inside conduit Interior: Handrail to upstairs - Handrail missing, potential safety issue. Recommend installing handrial Deferred Cost Items Improvement Items Exterior: Some screens are torn recommend repair Water Heater: Missing or repair/replace water heater catch pan. Recommend installing/replace catch pan Items To Monitor Roof:Some nail popping has occurred, recommend repair. Roof: Some shingles are heaving/lifting up, recommend repairRoof: Front Porch: Carpet is starting to come unglued/lifting up. Recommend monitor or repairExterior: Fascia loose, recommending resecuring Roof: Vent pipe boots cracking, recommend monitor or repair This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 3 Report Overview Scope of Inspection All components designated for inspection in the ASHI Standards of Practice are inspected, except as may be noted in the "Limitations of Inspection" sections within this report. It is the goal of the inspection to put a home buyer in a better position to make a buying decision. Not all improvements will be identified during this inspection. Unexpected repairs should still be anticipated. The inspection should not be considered a guarantee or warranty of any kind.Please refer to the pre-inspection contract for a full explanation of the scope of the inspection. Visual Inspection Only Roof: REMAINING Life Expectancy Roof: 5-10+ Main Entrance Faces North State of Occupancy Occupied Weather Conditions Cloudy Windy Recent Rain No Ground Cover Damp House in Perspective This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors Receipt/Invoice Majestic Home Inspectors 1204 Hanna Ave Maryville, TN 37804 (865) 264-0943 1704 Stone Slate Road Bedrock, AL 12345 Date: Thu. Oct. 1, 2015 1:15 Inspection Number: 1000tn09222015 Inspected By: Steve Mangham Client: Fred & Wilma Flintstone Inspection Home Inspection Fee $370.00 Total $370.00 1704 Stone Slate Road Bedrock, AL 12345 Page 5 Roof General None X All Partial Other Visibility Ladder at eaves Ground Inspected From X Roof Style of Roof X Gable Hip Mansard Type Low X Medium Steep Pitch Type: Roof Shed Flat With Binoculars Flat Other Asphalt Layers: 1 Age: REMAINING Life Expectancy Roof: 5-10+ Location: Comments Ventilation System None N/A X Soffit X Ridge Type Comments Flashing Material Condition Gable Roof Turbine Powered Other X Not Visible Galv/Alum Asphalt Copper Foam Rubber Not Visible X Satisfactory Marginal Poor Rusted Missing Separated from chimney/roof Recommend Sealing Other Lead Other Comments Valleys Material Condition Comments N/A X Not Visible Galv/Alum Not Visible X Satisfactory Asphalt Lead Marginal Poor Copper Holes Other Rusted Recommend Sealing Condition of Roof Coverings Satisfactory Marginal X Poor Curling Cracking Ponding Burn Spots Roof Broken/Loose Tiles/Shingles X Nail popping Granules missing Alligatoring Blistering Missing Tabs/Shingles/Tiles Moss buildup Exposed felt Cupping Incomplete/Improper Nailing Recommend roofer evaluate Evidence of Leakage Comments Some nail popping has occurred, recommend repair. Roof: Some shingles are heaving/lifting up, recommend repair This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 6 Photos Nail popping up Shingle ridge cap heaving upwards Skylights Condition Comments Yes X No Satisfactory Not Visible Marginal Poor Cracked/Broken Plumbing Vents X Yes No Satisfactory X Marginal Poor Cracking/Broken Condition Vent pipe boots cracking, recommend repair Comments Photos Leaking Need Replaced or Repaired Roof: Plumbing vent cracking, monitor This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 7 Grounds Service Walks Condition None X Concrete Brick Dirt Walkway / Gravel Not Visible Satisfactory Marginal Poor Trip hazard Typical cracks Settling cracks Public sidewalk needs repair Other Other Pitched towards home Comments Porch/Stoop & Steps / Front None Not Visible X Concrete Wood Metal Other Other Material Satisfactory X Marginal Poor Safety Hazard Condition: Front Porch Floor Painted - Potential Slip Hazard when Wet Cracks / Pits / Holes / Heaving Planks Lifting Up / Nails Lifting Up - Trip Hazard Wood In Contact With Soil No Attachment or Improper Attachement To Home - Repair Pitch Towards Home Typical Cracks Settling Cracks Trip Hazard Recommend Fill Cracks and Seal Recommend Re-Surface Comments: Flooring - Front Porch Comments: Flooring - Front Porch Front Porch: Carpet is starting to come unglued/lifting up. Recommend monitor or repair Wood Metal Other Other Step Material: Front Porch X Concrete Satisfactory Marginal X Poor X Safety Hazard Condition: Steps: Front Porch X Uneven Tread and/or Not Level Railing Missing Railing Loose / Repair Baluster Missing Balusters Loose / Repair Recommend Railing Recommend Balusters Need Railing Need Balusters Need Steps No Attachment or Improper Attachment To Home / Repair Comments: Steps - Front Porch Comments: Steps - Front Porch Front Porch: Steps - Safety/Trip Hazard - uneven tread/not level, recommend repair Photos Front Porch: Safety/Trip Hazard Steps uneven tread and Stepping Stone not level Porch/Stoop & Steps / Back X None Not Visible Concrete Wood Metal Other Other Material Satisfactory Marginal Poor Safety Hazard Condition: Front Porch Floor Painted - Potential Slip Hazard when Wet Cracks / Pits / Holes / Heaving Planks Lifting Up / Nails Lifting Up - Trip Hazard Wood In Contact With Soil No Attachment or Improper Attachement To Home - Repair Pitch Towards Home Typical Cracks Settling Cracks Trip Hazard Recommend Fill Cracks and Seal Recommend Re-Surface Comments: Flooring - Back Porch Comments: Flooring - Back Porch Concrete Wood Metal Other Other Step Material: Front Porch Satisfactory Marginal Poor Safety Hazard Condition: Steps: Back Porch This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 8 Grounds Porch/Stoop & Steps / Back cont. Condition: Steps: Back Porch cont. Comments: Steps - Back Porch Uneven Tread and/or Not Level Railing Missing Railing Loose / Repair Baluster Missing Balusters Loose / Repair Recommend Railing Recommend Balusters Need Railing Need Balusters Need Steps No Attachment or Improper Attachment To Home / Repair Comments: Steps - Back Porch Patio Material Condition None X Concrete Flagstone Kool-Deck Brick Wood Metel Satisfactory X Marginal Poor Settling cracks Trip hazard Pitched towards home (see remarks) X Typical cracks Heaving Wood In Contact With Soil Other Re-Surface / Repair Comments Deck/Balcony None Not Visible X Wood Metal Composite Conerete Treated Wood X Satisfactory Marginal Poor Safety Hazard Wood In Contact With Soil Railing Missing Railing Loose / Repair Balusters Missing Balusters Loose / Repair Recommend Railing Recommend Balusters Painted - Could Be A Slip Hazard when Wet Planks / Nails Lifting Up - Trip Hazard Support Bracing Underneath N/G Or Missing - Repair No Attachment or Improper Attachement To Home - Repair Comments: Deck / Balcony Satisfactory Marginal Poor Safety Hazard Uneven Tread And/Or Not Level Deck/Balcony - Steps Railing Missing Railing Loose / Repair Balusters Missing Balusters Loose / Repair Recommend Railing Recommend Balusters Need Steps Need Railing Need Balusters No Attachment or Imporper Attachment to Deck / Balcony - Repair Comments: Deck/Balcony - Steps Comments: Deck/Balcony - Steps Material Condition Deck/Patio/Porch Covers X None Satisfactory Marginal Poor Condition Moisture/Insect damage Metal Straps/Bolts/Nails/Flashing Recommend Comments Posts/Supports need Repair Improper attachment to home Earth to wood contact None Fence/Wall Type Condition Gate Comments Not evaluated None Brick Block Wood Metal X Chain Link Rusted Vinyl X Satisfactory Marginal Poor Typical cracks Loose Blocks/Caps Holes in Fence/Wall N/A X Satisfactory Marginal Poor Planks missing/damaged Operable: X Yes No Landscaping affecting foundation X N/A East West North South Satisfactory Recommend additional backfill Negative Grade Recommend window wells/covers Trim back trees/shrubberies Wood in contact with/improper clearance to soil Comments Retaining wall Material Condition Yes X No Brick Concrete Concrete block Railroad ties Satisfactory Marginal Poor Safety Hazard Drainage holes recommended Timbers Other Leaning/cracked/bowed Comments This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 9 Grounds Hose bibs Condition Operable Comments N/A X Satisfactory Marginal Poor No anti-siphon valve Recommend Anti-siphon valve No Splash Block Recommend Add Splash Block For Drainage Away From Home X Yes No Not Tested Utilities Not On This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 10 Exterior Chimney(s) None Location(s) South Ladder at eaves Ground (Inspection Limited) With Binoculars Viewed From X Roof No Recommended Rain Cap/Spark Arrestor X Yes X Brick Stone Metal Blocks Framed Chase Holes in metal Cracked chimney cap Loose mortar joints Flaking Loose brick Rust Evidence of X No apparent defects X Tile Metal Unlined Not Visible Flue Scaling Cracks Creosote Not evaluated Have flue(s) cleaned and re-evaluated Evidence of Recommend Cricket/Saddle/Flashing No apparent defects Marginal Poor Recommend Repair Over All Condition X Satisfactory Marginal Poor Monitor Chimney Flashing X Satisfactory Chimney Flashing: Missing or Covered up Bent/lifted up/rusting Recommend maintenance Satisfactory Marginal X Poor X Monitor Chimney Step Flashing Chimney Step Flashing: Missing or covered up X Bent/rusting/lifted up X Recomment maintenance Comments Chimney: Flashing has pulled away from the chimney - recommend repair Photos Chimney step flashing lifting, monitor or repair Gutters/Scuppers/Eavestrough None X Satisfactory Marginal Poor Rusting Downspouts needed Condition Needs to be cleaned Extensions Needed At Botton of Downspouts X Galvanized/Aluminum Vinyl/Plastic Copper Other Material Corners Joints Hole in main run X No apparent leaks Leaking Loose Missing spikes Improperly sloped X Satisfactory Attachment North South East West N/A Extension needed Comments Siding Material Condition Comments Trim Material Recommend repair/replace Splash Blocks Needed Stone Slate Block/Brick Fiberboard Fiber-cement Stucco EIFS* Not Inspected Asphalt Wood X Metal/Vinyl Other Typical cracks Peeling paint Monitor Wood rot Loose/Missing/Holes X Satisfactory Marginal Poor Recommend repair/painting Wood Fiberboard Aluminum/Steel X Vinyl Damaged wood Other Stucco Recommend repair/painting This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 11 Exterior Trim cont. Condition Comments X Satisfactory Marginal Poor Soffit Material Condition Comments None Wood Fiberboard Aluminum/Steel X Vinyl Damaged wood Other X Satisfactory Marginal Poor Stucco Recommend repair/painting Stucco Recommend repair/painting Stucco Recommend repair/painting Fascia Material Condition Comments None X Wood Fiberboard Aluminum/Steel Damaged wood Other Satisfactory X Marginal Poor Vinyl Exterior: Fascia loose, recommending resecuring Flashing Material Condition Comments None Wood Fiberboard Aluminum/Steel Damaged wood Other X Satisfactory Marginal Poor Vinyl Caulking Condition None X Satisfactory Marginal Poor Recommend around windows/doors/masonry ledges/corners/utility penetrations Comments Windows/Screens X Satisfactory Marginal Poor Wood rot Recommend repair/painting Condition Recommend repair/replace damaged screens Failed/fogged insulated glass Window Glass Broken/Cracked Wood X Metal Vinyl Aluminum/Vinyl clad Material X Torn Bent Not installed Satisfactory Screens Comments Exterior: Some screens are torn recommend repair Storms Windows Condition Material Putty Comments None Not installed X Satisfactory Marginal Poor Recommend repair/painting Wood Clad comb. Wood/Metal comb. X Metal X Satisfactory Needed N/A Broken/cracked Wood rot Slab-On-Grade/Foundation Poured concrete Post-Tensioned concrete Not Visible Other Foundation Wall X Concrete block X Satisfactory Marginal Poor Have Evaluated Not Evaluated Monitor Condition N/A X Not Visible Satisfactory Poor Monitor Have Evaluated Marginal Concrete Slab Comments Service Entry - Electric X Underground Overhead Location X Satisfactory Marginal Poor Weather head/mast needs repair Condition Overhead wires too low over Ground/Roof/Deck/Balcony This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 12 Exterior Service Entry - Electric cont. Service Riser Conduit Loose or Need Repair Less than 3ft from balcony/deck/window Condition cont. Potential Safety Hazard Exposed wiring - Romex/Extension Cord No Operable: X Yes No Condition: X Satisfactory Marginal Poor Exterior receptacles X Yes No Operable: Yes No Safety Hazard Reverse polarity Open ground(s) GFCI present X Yes Recommend GFCI Receptacles Comments Building(s) Exterior Wall Construction Not Visible X Framed Masonry Log Other Type X Not Visible Satisfactory Marginal Poor Condition Comments Exterior Doors Main Entrance Patio Rear door Other door N/A Weatherstripping: X Satisfactory Door condition: X Satisfactory Marginal X N/A Weatherstripping: Satisfactory Door condition: Satisfactory Marginal N/A Weatherstripping: X Satisfactory Door condition: X Satisfactory Marginal X N/A Weatherstripping: Satisfactory Door condition: Satisfactory Marginal Marginal Poor Marginal Poor Marginal Poor Marginal Poor Poor Missing Replace Poor Missing Replace Poor Missing Replace Poor Missing Replace Comments Exterior A/C - Heat pump #1 N/A Unit #1 Location: North Brand: Goodman Model #: GPG1330070M41BA Serial #: 1406391974 Approximate Age: 1 yr X Satisfactory Marginal Poor Cabinet/housing rusted Condition Other Energy source Electric X Gas X Air cooled Water cooled Geothermal Heat pump Unit type No Maximum fuse/breaker rating (amps): 35 Fuses/Breakers installed (amps): 30 Outside Disconnect X Yes Improperly sized fuses/breakers X Yes No Recommend re-level unit Level Marginal Poor Damaged Needs cleaning Damaged base/pad Condenser Fins X Satisfactory Damaged Refrigerant Line X Yes No Replace Insulation Marginal Poor Improper Clearance (air flow) X Satisfactory Comments Exterior A/C - Heat pump #2 X N/A Unit #2 Location: Brand: Model #: Serial #: Approximate Age: Satisfactory Marginal Condition Gas Other Energy source Electric Poor Cabinet/housing rusted This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 13 Exterior Exterior A/C - Heat pump #2 cont. Air cooled Water cooled Geothermal Heat pump Unit type Yes No Maximum fuse/breaker rating (amps): Fuses/Breakers installed (amps): Outside Disconnect Improperly sized fuses/breakers Yes No Recommend re-level unit Level Satisfactory Marginal Poor Damaged Needs cleaning Damaged base/pad Condenser Fins Damaged Refrigerant Line Yes No Replace Insulation Satisfactory Marginal Poor Improper Clearance (air flow) Comments This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 14 Garage/Carport Type None X Attached Type Insulation Batt in Ceiling Comments Detached N/A X Yes 1-Car X 2-Car No 3-Car 4-Car Carport Automatic Opener None N/A X Operable Inoperable Operation Comments Safety Reverse Operation None N/A X Operable Not Operable Need(s) adjusting Safety Hazard X Photo eyes and Pressure reverse tested Comments Roofing Material Comments X Same as house Covering type: Gutters/Eavestrough None Condition Comments Satisfactory Approx. layers: Marginal Approx. age: Poor X Same as house Siding Material Condition Comments N/A X Same as house Wood X Satisfactory Marginal Metal Poor N/A X Same as house Wood X Satisfactory Marginal Aluminum Vinyl Poor Recommend repair/replace Vinyl Stucco Masonry Slate Fiberboard Recommend repair/replace Recommend painting Log Trim Material Condition Comments Recommend painting Floor Material Condition X Concrete Gravel Asphalt Dirt Other X Satisfactory Marginal Poor Safety Hazard Recommend evaluation/repair Large settling cracks X Typical cracks X Bruners are Less than 18" above garage floor Safety Hazard N/A X Yes No Source of Ignition within 18" of the floor Garage: Source of ignition less than 18" of floor, Safety Hazard, Recommend raising ignition source above Comments 18" Sill Plates Type Condition Comments None X Not Visible Floor level Elevated Rotted/Damaged Recommend repair Overhead Door(s) N/A Wood Fiberglass Masonite X Metal Material X Satisfactory Marginal Poor Hardware loose Condition Safety Cable Recommended This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 15 Garage/Carport Overhead Door(s) cont. Weatherstripping missing/damaged Loose/missing Condition cont. Yes X No Recommend Priming/Painting Inside & Edges Comments Exterior Service Door None X Satisfactory Condition Comments Marginal Poor Damaged/Rusted Recommmend repair Recommend repair/replacement Electrical Receptacles X Yes No Not Visible Operable: X Yes No Yes X No Safety Hazard Reverse polarity Yes X No Safety Hazard Open ground No Operable: X Yes No Handyman/extension cord wiring GFCI Present X Yes Recommend GFCI Receptacles Comments Firewall between Garage & Living Area N/A X Present Missing Recommend repair X Satisfactory Marginal Poor Safety hazard Holes in walls/ceiling Condition Yes X No Moisture Stains Present Yes X No Typical Cracks X Not verifiable Not a fire door Needs repair Satisfactory Fire door N/A Satisfactory Marginal Poor X Missing Inoperative Self closure Firewall Door: No self closing mechanism, recommend installing self closing mechanism Comments This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 16 Dining Room Dining Room Location First floor Marginal Poor Typical cracks Damage Walls & Ceiling X Satisfactory Yes X No Moisture stains Where: X Satisfactory Marginal Poor Squeaks Slopes Heaving/Buckling Tripping hazard Floor X None Satisfactory Marginal Poor Recommend repair/replace Ceiling fan Switches: X Yes No X Operable Receptacles: X Yes No X Operable Electrical Open ground/Reverse polarity: Yes X No Safety hazard Cover plates missing No Holes: Doors Walls Ceilings Heating source present X Yes X None Satisfactory Marginal Poor Cracked glass Broken/Missing hardware Doors None X Satisfactory Marginal Poor Cracked glass Evidence of leaking insulated glass Windows Broken/Missing hardware Comments This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 17 Kitchen Countertops Condition Comments X Satisfactory Marginal Poor Recommend repair/caulking Cabinets Condition Comments X Satisfactory Marginal Poor Recommend repair/adjustment Plumbing Yes X No Recommend Repair Faucet Leaks Yes X No Recommend Repair Pipes leak/corroded X Satisfactory Marginal Poor Cracked Sink/Faucet Marginal Poor Functional drainage X Satisfactory Marginal Poor Functional flow X Satisfactory Comments Walls & Ceiling X Satisfactory Condition Comments Corroded Marginal Poor Typical cracks Marginal Poor Sloping X Squeaks Chipped Moisture stains Recommend repair Holes in wall/ceiling Heating/Cooling Source X Yes No Comments Floor Condition X Satisfactory Trip Hazard Flooring heaving/buckling Comments Appliances N/A Not tested Operable: X Yes No Disposal N/A Not tested Operable: X Yes No Oven N/A Not tested Operable: X Yes No Range N/A Not tested Operable: X Yes No Dishwasher Not tested Operable: Yes No Trash Compactor X N/A N/A Not tested Operable: X Yes No Exhaust fan N/A Not tested Operable: X Yes No Refrigerator N/A Not tested Operable: X Yes No Microwave : Operable: Yes X No Other Yes No X Not visible Dishwasher airgap Yes X No Not visible Dishwasher drain line looped No Operable: X Yes No Receptacles present X Yes X Yes No Operable: Yes No Recommend GFCI Receptacles: GFCI Potential Safety Hazard(s) Yes X No Potential Safety Hazard Open ground/Reverse polarity: Comments Yes No This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 18 Living Room Living Room Location Walls & Ceiling Moisture stains X Satisfactory Marginal Poor Typical cracks Damage / holes Yes X No Where: X Satisfactory Marginal Poor Squeaks Slopes Heaving/Buckling Tripping hazard Floor None X Satisfactory Marginal Poor Recommend repair/replace Ceiling fan Switches: X Yes No X Operable Receptacles: X Yes No X Operable Electrical Open ground/Reverse polarity: Yes X No Safety hazard Cover plates missing No Holes: Doors Walls Ceilings Heating source present X Yes X None Satisfactory Marginal Poor Cracked glass Broken/Missing hardware Doors None X Satisfactory Marginal Poor Cracked glass Evidence of leaking insulated glass Windows Broken/Missing hardware Comments This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 19 Interior Fireplace None Location(s) Gas X Wood Solid fuel burning stove Electric Ventless Type X Masonry Metal (pre-fabricated) Metal insert Cast Iron Material Blower built-in Operable: Yes No Damper operable: X Yes No Miscellaneous Open joints or cracks in firebrick/panels should be sealed Fireplace doors need repair Yes No Damper missing Damper modified for gas operation X N/A No Recommend repair - cracked/loose Hearth extension adequate X Yes Hearth Less-Than 18" / <3' opening / 8" beyond mouth Hearth Less-Than 20" / >3' opening / 12" beyond mouth N/A X Secure Loose Recommend repair/replace Mantel Marginal Poor Recommend having flue cleaned and re-examined Physical condition X Satisfactory Not evaluated Comments Stairs/Steps/Balconies None X Satisfactory Marginal Poor Loose/Missing Condition Satisfactory Marginal X Poor X Safety hazard X Hand Rail/Railing/Balusters recommended Handrail Marginal Poor Risers/Treads uneven Trip hazard Risers/Treads X Satisfactory Comments Interior: Handrail to up stairs - Handrail missing, potential safety issue. Recommend installing handrail Smoke/Carbon Monoxide detectors Not Present Operable: X Yes No Not tested Recommend additional Smoke Detector X Present Safety Hazard Comments Present X Not Present Operable: Yes No Not tested Recommend additional CO Detector Safety Hazard Carbon Monoxide Detectors: None installed. With fuel heat, carbon monoxide detectors could be installed to Comments detect for carbon monoxide Attic/Structure/Framing/Insulation N/A Stairs Pulldown X Scuttlehole/Hatch No Access Other Access Access limited by: Access panel X In the attic Other Inspected from Bedroom Closet Garage Laundry Room Other Other Location Of Access X Hallway / Hall Closet Complete Partial X None Flooring In Attic X Fiberglass Batts X Loose Cellulose Foam Other Vermiculite Rock wool Insulation Depth: 8 inches Damaged Displaced Missing Compressed Recommend additional insulation X Between ceiling joists Rafters/Trusses Walls Underside of roof deck Not Visible Installed in X Ventilation appears adequate Recommend additional ventilation Recommend baffles at eaves Ventilation Yes X No Recommend repair Outside: X Yes No Not Visible Fans exhausted to Attic: Bath Fan Exhausted to Attic Stove Vent Hood Exhausted in Attic N/A X Satisfactory Damaged Split Disconnected Leaking Repair/Replace HVAC Duct in Attic Recommend Insulation N/A X Satisfactory Needs repair Not Visible Chimney chase Yes X No Recommend repair Structural problems observed Trusses Wood Metal X Collar ties X Purlins Knee wall Not Visible Roof structure X Rafters Other Wood X Metal Not Visible Ceiling joists Satisfactory Marginal Poor Buckled Plywood X OSB Planking Rotted Sheathing This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 20 Interior Attic/Structure/Framing/Insulation cont. Stained Delaminated Sheathing cont. Yes X No Evidence of condensation Yes X No Evidence of moisture Yes X No Evidence of leaking Yes No Needs repair/sealing Firewall between units X N/A X No apparent defects Open junction box(es) Handyman wiring Electrical Knob and tube covered with insulation Safety Hazard Comments This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 21 Laundry Room Laundry Laundry sink X N/A Yes X No Faucet leaks Yes X None apparent Cross connections No Heat source present X Yes No Room vented X Yes N/A X Wall Ceiling Floor Not vented Plastic dryer vent not recommended Dryer vented Not vented to exterior Recommend repair Safety hazard Open ground/reverse polarity: Yes X No Safety hazard Electrical Yes X No Operable: Yes No Recommend GFCI Receptacles GFCI present X Washer X Dryer Water heater Furnace/Boiler Appliances Leaking Corroded Not Visible Washer hook-up lines/valves X Satisfactory Yes No Cap Needed Safety hazard Not Visible Gas shut-off valve X N/A Comments This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 22 Master Bedroom Room Location Second floor Type Marginal Poor Typical cracks Damage Walls & Ceiling X Satisfactory Yes X No Ceiling Wall Moisture stains X Satisfactory Marginal Poor Squeaks Slopes Heaving Tripping hazard Floor None X Satisfactory Marginal Poor Recommend repair/replace Ceiling fan Switches: X Yes No X Operable Receptacles: X Yes No X Operable Electrical Open ground/Reverse polarity: Yes X No Safety hazard Cover plates missing No Vent Register Missing/Bent Recommend Replace/Repair Heating source present X Yes Yes No Bedroom Egress restricted X N/A None X Satisfactory Marginal Poor Cracked glass Broken/Missing hardware Doors None X Satisfactory Marginal Poor Cracked glass Evidence of leaking insulated glass Windows Broken/Missing hardware Comments This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 23 Bedroom 1 Room 2nd floor Location Type Marginal Poor Typical cracks Damage Walls & Ceiling X Satisfactory Yes X No Ceiling Wall Moisture stains X Satisfactory Marginal Poor Squeaks Slopes Heaving Tripping hazard Floor None X Satisfactory Marginal Poor Recommend repair/replace Ceiling fan Switches: X Yes No X Operable Receptacles: X Yes No X Operable Electrical Open ground/Reverse polarity: Yes X No Safety hazard Cover plates missing No Vent Register Missing/Bent Recommend Replace/Repair Heating source present X Yes N/A Yes No Bedroom Egress restricted None X Satisfactory Marginal Poor Cracked glass Broken/Missing hardware Doors None X Satisfactory Marginal Poor Cracked glass Evidence of leaking insulated glass Windows Broken/Missing hardware Comments This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 24 Bedroom 2 Room 2nd floor Location Type Marginal Poor Typical cracks Damage Walls & Ceiling X Satisfactory Yes X No Ceiling Wall Moisture stains Satisfactory Marginal Poor X Squeaks Slopes Heaving Tripping hazard Floor None X Satisfactory Marginal Poor Recommend repair/replace Ceiling fan Switches: X Yes No X Operable Receptacles: X Yes No X Operable Electrical Open ground/Reverse polarity: Yes X No Safety hazard Cover plates missing No Vent Register Missing/Bent Recommend Replace/Repair Heating source present X Yes Yes No Bedroom Egress restricted X N/A None X Satisfactory Marginal Poor Cracked glass Broken/Missing hardware Doors None X Satisfactory Marginal Poor Cracked glass Evidence of leaking insulated glass Windows Broken/Missing hardware Comments This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 25 Bedroom 3 Room 2nd floor Location Type Marginal Poor Typical cracks Damage Walls & Ceiling X Satisfactory Yes X No Ceiling Wall Moisture stains X Satisfactory Marginal Poor Squeaks Slopes Heaving Tripping hazard Floor None X Satisfactory Marginal Poor Recommend repair/replace Ceiling fan Switches: X Yes No X Operable Receptacles: X Yes No X Operable Electrical Open ground/Reverse polarity: Yes X No Safety hazard Cover plates missing No Vent Register Missing/Bent Recommend Replace/Repair Heating source present X Yes Yes No Bedroom Egress restricted X N/A None X Satisfactory Marginal Poor Cracked glass Broken/Missing hardware Doors None X Satisfactory Marginal Poor Cracked glass Evidence of leaking insulated glass Windows Broken/Missing hardware Comments This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 26 Bonus Room 4 Room X N/A : Location Type Satisfactory Marginal Poor Typical cracks Damage Walls & Ceiling Yes No Ceiling Wall Moisture stains Satisfactory Marginal Poor Squeaks Slopes Heaving Tripping hazard Floor None Satisfactory Marginal Poor Recommend repair/replace Ceiling fan Switches: Yes No Operable Receptacles: Yes No Operable Electrical Open ground/Reverse polarity: Yes No Safety hazard Cover plates missing Yes No Vent Register Missing/Bent Recommend Replace/Repair Heating source present N/A Yes No Bedroom Egress restricted None Satisfactory Marginal Poor Cracked glass Broken/Missing hardware Doors None Satisfactory Marginal Poor Cracked glass Evidence of leaking insulated glass Windows Broken/Missing hardware Comments This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 27 Master Bathroom 1 Bath Location Sinks Tubs Showers Toilet Whirlpool Faucet leaks: Yes X No Pipes leak: Yes X No N/A Faucet leaks: Yes X No Pipes leak: Yes No X Not Visible N/A Faucet leaks: Yes X No Pipes leak: Yes No X Not Visible Bowl loose: X Yes No Operable: X Yes No Cracked bowl Toilet leaks Yes X No Operable: Yes No Not tested No access door GFCI: Yes No GFCI Recommended Ceramic/Plastic X Fiberglass Masonary/Tile Other Shower/Tub area Caulk/Grouting needed: Yes No Where: Floor Tile/Vinyl Cracked: Moisture could leak to sub-floor causing rot Sink: Hot / Cold water supply reversed: Repair Safety Hazard Sink Stopper not working/missing: Repair Tub: Hot / Cold water supply reversed: Repair Safety Hazard Tub Stopper not working/missing: Repair Towel rack missing: Replace/repair Condition: Satisfactory Marginal Poor Rotted floors Comments: Master Bath: Toilet bowl is loose recommend repair X Satisfactory Marginal Poor Drainage X Satisfactory Marginal Poor Water flow Yes X No Walls Ceilings Cabinetry Moisture stains present X Satisfactory Marginal Poor Doors None X Satisfactory Marginal Poor Window No Operable: X Yes No Receptacles present X Yes X Yes No Operable: X Yes No Recommend GFCI GFCI Yes X No Potential Safety Hazard Open ground/Reverse polarity No Heat source present X Yes X Yes No Operable: X Yes No Noisy Exhaust fan X Satisfactoryt Marginal Poor Flooring Tile cracked: Repair - moisture could get to sub-floor and cause rot Vinyl cracked/split: Repair - moisture could get to sub-floor and cause rot Comments X Tile X Yes Vinyl Yes This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 28 Bathroom 2 (Hall) Bath Location Sinks Tubs Showers Toilet Whirlpool 2nd floor Faucet leaks: Yes X No Pipes leak: Yes X No N/A Faucet leaks: Yes X No Pipes leak: Yes No X Not Visible N/A Faucet leaks: Yes X No Pipes leak: Yes No X Not Visible Bowl loose: X Yes No Operable: Yes No Cracked bowl Toilet leaks Yes X No Operable: Yes No Not tested No access door GFCI: Yes No GFCI Recommended Ceramic/Plastic X Fiberglass Masonary/Tile Other Shower/Tub area Caulk/Grouting needed: Yes X No Where: Floor Tile/Vinyl Cracked: Moisture could leak to sub-floor causing rot Sink: Hot / Cold water supply reversed: Repair Safety Hazard Sink Stopper not working/missing: Repair Tub: Hot / Cold water supply reversed: Repair Safety Hazard Tub Stopper not working/missing: Repair Towel rack missing: Replace/repair Condition: X Satisfactory Marginal Poor Rotted floors Comments: X Satisfactory Marginal Poor Drainage X Satisfactory Marginal Poor Water flow Yes X No Walls Ceilings Cabinetry Moisture stains present X Satisfactory Marginal Poor Doors X None Satisfactory Marginal Poor Window No Operable: X Yes No Receptacles present X Yes X Yes No Operable: X Yes No Recommend GFCI GFCI Yes X No Potential Safety Hazard Open ground/Reverse polarity No Heat source present X Yes X Yes No Operable: X Yes No Noisy Exhaust fan X Satisfactoryt Marginal Poor X Tile Yes Flooring Tile cracked: Repair - moisture could get to sub-floor and cause rot Vinyl Yes Vinyl cracked/split: Repair - moisture could get to sub-floor and cause rot Comments This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 29 Bathroom 3 (1/2) Bath 1st floor Location Faucet leaks: Yes X No Pipes leak: Yes X No Sinks N/A Faucet leaks: Yes X No Pipes leak: Yes No X Not Visible Showers Bowl loose: Yes X No Operable: X Yes No Cracked bowl Toilet leaks Toilet X Satisfactory Marginal Poor Drainage X Satisfactory Marginal Poor Water flow Yes X No Walls Ceilings Cabinetry Moisture stains present X Satisfactory Marginal Poor Doors X None Satisfactory Marginal Poor Window No Operable: X Yes No Receptacles present X Yes X Yes No Operable: X Yes No Recommend GFCI GFCI Yes X No Potential Safety Hazard Open ground/Reverse polarity No Heat source present X Yes X Yes No Operable: X Yes No Noisy Exhaust fan X Satisfactory Marginal Poor Tile Yes Flooring Tile cracked: Repair - moisture could get to sub-floor and cause rot Vinyl Vinyl cracked/split: Repair - moisture could get to sub-floor and cause rot Comments Yes This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 30 Bathroom 4 Bath Location Sinks Tubs Showers Toilet Whirlpool X N/A Location: Faucet leaks: Yes No Pipes leak: Yes No N/A Faucet leaks: Yes No Pipes leak: Yes No Not Visible N/A Faucet leaks: Yes No Pipes leak: Yes No Not Visible Bowl loose: Yes No Operable: Yes No Cracked bowl Toilet leaks Yes No Operable: Yes No Not tested No access door GFCI: Yes No GFCI Recommended Ceramic/Plastic Fiberglass Masonary/Tile Other Shower/Tub area Caulk/Grouting needed: Yes No Where: Floor Tile/Vinyl Cracked: Moisture could leak to sub-floor causing rot Sink: Hot / Cold water supply reversed: Repair Safety Hazard Sink Stopper not working/missing: Repair Tub: Hot / Cold water supply reversed: Repair Safety Hazard Tub Stopper not working/missing: Repair Towel rack missing: Replace/repair Condition: Satisfactory Marginal Poor Rotted floors Comments: Satisfactory Marginal Poor Drainage Satisfactory Marginal Poor Water flow Yes No Walls Ceilings Cabinetry Moisture stains present Satisfactory Marginal Poor Doors None Satisfactory Marginal Poor Window Yes No Operable: Yes No Receptacles present Yes No Operable: Yes No Recommend GFCI GFCI Yes No Potential Safety Hazard Open ground/Reverse polarity Yes No Heat source present Yes No Operable: Yes No Noisy Exhaust fan Satisfactoryt Marginal Poor Tile Yes Flooring Tile cracked: Repair - moisture could get to sub-floor and cause rot Vinyl Yes Vinyl cracked/split: Repair - moisture could get to sub-floor and cause rot Comments New Value Location (20) This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 31 Basement Stairs Condition X Satisfactory Marginal Poor Typical wear and tear Need repair Risers Uneven Safety Hazard X Yes No Condition: X Satisfactory Loose Handrail/Railing/Balusters recommended Handrail Low clearance Safety hazard Headway over stairs X Satisfactory Comments Foundation Condition X Satisfactory Marginal Poor Efflorescence present Have evaluated Monitor Not Elevated ICF Brick X Concrete block Stone Masonry Poured concrete wood Material North South East West Horizontal cracks X None X None North South East West Step cracks North South East West Vertical cracks X None None X North X South East West Finished Basement / Walls Covered North South East West Movement apparent X None Yes X No Fresh Old stains North South East West Indication of moisture Comments Floor Material Condition Comments Concrete Dirt/Gravel X Not Visible Other X Satisfactory Marginal Poor Typical cracks Not Visible Seismic bolts Condition Comments Drainage Sump pump Floor drains Comments X N/A None visible Appear satisfactory Recommend evaluation Yes X No Working Not working Needs cleaning Pump not tested Yes X No X Not Visible Efflorescence Present Drains not tested Girders/Beams Condition Material Comments X Not Visible Satisfactory Marginal Poor Stained/Rusted Steel X Wood Concrete Block Not Visible Columns Condition Material Comments X Not Visible Satisfactory Marginal Poor Stained/Rusted Steel Wood Concrete Block Not Visible Joists Condition Material Not Visible X Satisfactory Marginal X Wood Steel Truss Not Visible Poor Sagging/altered joist Engineered I-Type (Knock-outs) X 2x8 2x10 2x12 Comments Subfloor Condition Comments X Not Visible Satisfactory Marginal Poor Indication of moisture stains/rotting This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 32 Crawl Space Crawl space X N/A Full crawlspace Combination basement/crawl space/slab Type Yes No Signs of moisture Moisture Reading: Conditioned (heated/cooled) N/A Yes No Satisfactory Marginal Poor Falling down Insulation Batt in Ceiling Install/Repair/Replace N/A Satisfactory Marginal Poor Damaged Split Disconnected Leaking HVAC Duct Repair/Replace Comments Access Location Inspected from Exterior hatch/door Interior hatch/door Access Opening In the crawl space Access to low to enter Via basement No access Could not enter because of debris Comments Foundation walls Satisfactory Marginal Poor Condition Monitor Have Evaluated Concrete block Poured concrete Material Comments Floor Material Condition Comments Concrete Gravel Dirt Typical cracks Not Visible Monitor Cracks Brick Stone (7) Other Yes - Vapor barrier present Movement ICF Efflorescence present Wood No - Vapor barrier not present Seismic bolts Condition Comments N/A None visible Appear satisfactory Recommed evaluation Drainage Yes No Operable: Yes Sump pump Yes No Not Visible Standing water Yes No Evidence of moisture damage Comments No Pump not tested Ventilation Location Condition Comments N/A Wall vents Power vents None apparent Additional ventilation recommended Evidence of moisture damage Girders/Beams/Columns Steel Wood Masonry Material Satisfactory Marginal Poor Condition Comments Joists Material Condition Comments Not Visible Sagging/Altered Wood Steel Truss Not Visible 2x8 2x10 Engineered I-Type (Knock-outs) Sagging/Altered joists Satisfactory Marginal Poor 2x12 This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 33 Crawl Space Subfloor Condition Comments Not Visible Indication of moisture stains/rotting Insulation None Fiberglass Rockwool Type / on ceiling Walls Between floor joists Location Comments Vapor barrier Present Material Condition Comments Yes No Not Visible Kraft/foil faced Plastic Satisfactory Marginal Batt Other Cellulose (Paper Fiber) Foam Not Visible Improperly installed Not Visible Other Poor This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 34 Plumbing System Water service Main shut-off location In the garage In Home main shut-off off valve location: In garage Not Visible X Copper/Galv. Plastic Unknown Water entry piping Yes No Service entry Lead other than solder joints X Unknown Marginal Poor Copper Galvanized X PVC Plastic Visible water distribution piping X Satisfactory PEX Plastic Other X Satisfactory Marginal Poor Water pressure over 80 psi Recommend plumber evaluate Flow Recommend pressure regulator Corroded Leaking Valves broken/missing Dissimilar metal Pipes Supply/Drain Cross connection: Yes No Safety Hazard Recommend repair Recommend a dielectric union Satisfactory Copper Cast iron Galvanized X PVC ABS Brass Drain/Waste/Vent pipe X Satisfactory Marginal Poor Condition N/A Support/Insulation Type: No P-traps recommended Traps proper P-Type X Yes X Satisfactory Marginal Poor Drainage Yes No Leaking: Yes No Interior fuel storage system X N/A X N/A Copper Brass Black iron Stainless steel CSST Not Visible Galvanized Fuel line Recommend CSST be properly bonded X N/A Satisfactory Marginal Poor Recommend plumber evaluate Condition Comments Main fuel shut-off location N/A Location On the side exterior wall Comments Well pump X N/A Submersible In basement Well house Well pit Type Yes No Well pressure: Not Visible Pressure gauge operable Comments Shared well Sanitary/Grinder pump X N/A Operable: Yes No Yes No Sealed Crock Sealed crock: Yes No Check Valve Check valve: Yes No Shut-off Valve Shut-off valve: Yes No Vented Comments Water heater #1 N/A Brand Name: Whirlpool Model #: E2F4RD045V Serial #: 1449100586236 Approx. age: 1 year Capacity: 40 Unknown/Could not read label Gas X Electric Oil LP Other Type Yes No N/A Combustion air venting present X Yes No Extension proper: X Yes No Missing Recommend repair Improper material Relief valve X Satisfactory Marginal Poor Water Heater Catch Pan Condition X Water Heater Catch Pan - missing/damaged X Water Heater Catch Pan - Recommend installing/replacing Satisfactor Marginal Poor X Safety Hazard X Wiring is Exposed Water Heater Wiring General This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 35 Plumbing System Water heater #1 cont. Water Heater Wiring cont. Water Heater Catch Pan X Repair - Repair conduit / Install conduit over wire Water Heater Wiring: Safety Hazard: Wiring Exposed, recommend install wire inside conduit Yes X No Water Heater: Recommend installing catch pan Water Heater: Recommend installing catch pan Comments Water heater #2 X N/A Brand Name: Model #: Serial #: Approx. age: Capacity: Unknown/Could not read label General Gas Electric Oil LP Other Type Yes No N/A Combustion air venting present Yes No Extension proper: Yes No Missing Recommend repair Improper material Relief valve Satisfactory Marginal Poor Water Heater catch pan Condition Water Heater Catch Pan - missing/damaged Water Heater Catch Pan - Recommend installing/replacing Satisfactor Marginal Poor Safety Hazard Wiring is Exposed Water Heater Wiring Repair - Repair conduit / Install conduit over wire Yes No Recommend: installing/replace Water Heater Catch Pan Comments Water softener X None Yes No Loop installed Yes No Plumbing hooked up Yes No Plumbing leaking Comments This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 36 Heating/Cooling System - Evaporator/Heat Exchanger Heating system - Evaporator/Heat Exchanger Marginal Poor Unit #1 - Evaporator/Heat Exchanger X Satisfactory Brand name: Goodman Approx. age: 1 YEAR Unknown/Could not read label Model #: GPG1330070M41BA Serial #: 1406391974 Max Fuse Size: 35 Size Breaker/Fuse installed: 30 Disconnect: X Yes No Disconnect Means: Switch X Pull-Out Breaker/Fuse Wiring Exposed / Need Repair Safety Hazard Recommended HVAC technician examine Natural Gas LP Oil Solid fuel Energy source Electric Floor/wall furnace Direct drive Belt drive Gravity Warm air system X Central system N/A Sealed X Not Visible Visual w/mirror Flame distortion Rusted Heat exchanger Carbon/soot buildup Detected at plenum Detected at register Not tested Carbon monoxide X N/A Tester: Yes No Combustion air venting present X N/A Disconnect: X Yes No Normal operating and safety controls observed Controls Gas shut off valve: X Yes No Gas pipe Clean-Out Nipple: X No Recommend installing Gas pipe Clean-Out Nipple X Metal duct Insulated flex duct Cold air returns Duct board Asbestos-like wrap Distribution Safety Hazard N/A X Satisfactory Rusted Improper slope Safety hazard Recommend repair/replace Flue piping X Standard Electrostatic Satisfactory Needs cleaning/replacement Missing Filter Electronic (not tested) Did not fire Proper operation: X Yes No Not tested When turned on by thermostat X Fired X N/A Supplemental electric Supplemental gas Heat pump Satisfactory Marginal Poor Water/Sand Observed: Yes No Sub-slab ducts X N/A Exterior temperature Other System not operated due to X N/A Comments Marginal Poor Needs cleaning Damaged Evaporator Coil X Satisfactory Marginal Poor Leak/Oil present Damaged Insulation missing Refrigerant Lines X Satisfactory Marginal Poor No P-Trap: install Drain to exterior Condensate Line/Drain X Satisfactory Drain to a pump Drain to floor drain Operation / Differential Differential: 15 Temp reading at register: 85 Temp reading at return: 70 X Satisfactory Marginal Poor Recommend HVAC technician examine/clean/service Condition Did not operated due to exterior temperature at or below 60° Comments Heating System #2 - Evaporator/Heat Exchanger None Satisfactory Marginal Poor Unit #2 - Evaporator/Heat Exchanger Brand name: Approx. age: Unknown/Could not read label Model #: Serial #: Max Fuse Size: Size Breaker/Fuse installed: Disconnect: Yes Disconnect Means: Switch Pull-Out Breaker/Fuse Wiring Exposed / Need Repair Safety Hazard Recommended HVAC technician examine Natural Gas LP Oil Solid fuel Energy source Electric Central system Floor/wall furnace Direct drive Belt drive Gravity Warm air system N/A Sealed Not Visible Visual w/mirror Flame distortion Rusted Heat exchanger Carbon/soot buildup N/A Detected at plenum Detected at register Not tested Carbon monoxide Tester: No This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 37 Heating/Cooling System - Evaporator/Heat Exchanger Heating System #2 - Evaporator/Heat Exchanger cont. N/A Yes No Combustion air venting present Disconnect: Yes No Normal operating and safety controls observed Controls Gas shut off valve: Yes No Gas pipe Clean-Out Nipple: No Recommend installing Gas pipe Clean-Out Nipple Metal duct Insulated flex duct Cold air returns Duct board Asbestos-like wrap Distribution Safety Hazard N/A Satisfactory Rusted Improper slope Safety hazard Recommend repair/replace Flue piping Standard Electrostatic Satisfactory Needs cleaning/replacement Missing Filter Electronic (not tested) Fired Did not fire Proper operation: Yes No Not tested When turned on by thermostat N/A Supplemental electric Supplemental gas Heat pump N/A Satisfactory Marginal Poor Water/Sand Observed: Yes No Sub-slab ducts N/A Exterior temperature Other System not operated due to Comments Satisfactory Marginal Poor Needs cleaning Damaged Evaporator Coil Satisfactory Marginal Poor Leak/Oil present Damaged Insulation missing Refrigerant Lines Satisfactory Marginal Poor No P-Trap: install Drain to exterior Condensate Line/Drain Drain to a pump Drain to floor drain Operation / Differential Differential: Temp reading at register: Temp reading at return: Satisfactory Marginal Poor Recommend HVAC technician examine/clean/service Condition Did not operated due to exterior temperature at or below 60° Comments Boiler system N/A Brand name: Approx. age: Model #: Serial #: LP Oil Electric Solid fuel Energy source Gas Hot water Baseboard Steam Radiator Radiant floor Distribution Pump Gravity Multiple zones Circulator Temp/pressure gauge exist: Yes No Operable: Yes No Controls Yes No Oil fired units Disconnect: Yes No N/A Combustion air venting present Yes No Missing Extension proper: Yes No Recommend repair/replace Relief valve When turned on by thermostat: Fired Did not fire Operated Satisfactory: Yes No Recommend HVAC technician examine before closing Operation Comments General Other systems N/A Electric baseboard Type Yes No Proper operation Satisfactory System condition Comments Radiant ceiling cable Marginal Poor Gas space heater Solid fuel burning stove Recommend HVAC Technician Examine This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 38 A/C Condenser Cooling System A/C Unit #1 Condenser Cooling System Marginal Poor Unit #1 - A/C Condenser X Satisfactory Brand name: Goodman Approx. age: 1 yr Unknown/Could not read label Model #: GPG1330070M41BA Serial #: 1406391974 Max Fuse Size: 35 Size Breaker/Fuse installed: 30 Disconnect: X Yes No Disconnect Means: Switch X Pull-Out Breaker/Fuse Wiring Exposed / Need Repair Safety Hazard Recommended HVAC technician examine Natural Gas (5) LP (6) Energy source X Electric Did not fire Proper operation: X Yes No Not tested When turned on by thermostat X Fired X N/A Yes No Heat pump Marginal Poor Needs cleaning Damaged Condensation Coil X Satisfactory Marginal Poor Insulation missing Leak/Oil present Damaged Refrigerant Lines X Satisfactory Marginal Poor No P-Trap: install Condensate Lines/Drain X Satisfactory X Satisfactory Marginal Poor Recomment HVAC technician examine/clean/service Condition Did not operate due to temperature at or less than 60° Comments A/C Unit #2 Condenser Cooling System Satisfactory Marginal Poor Unit #2 - A/C Condenser X None Brand name: Approx. age: Unknown/Could not read label Model #: Serial #: Max Fuse Size: Size Breaker/Fuse installed: Disconnect: Yes No Disconnect Means: Switch Pull-Out Breaker/Fuse Wiring Exposed / Need Repair Safety Hazard Recommended HVAC technician examine Natural Gas (5) LP (6) Energy source Electric Fired Did not fire Proper operation: Yes No Not tested When turned on by thermostat N/A Yes No Heat pump Satisfactory Marginal Poor Needs cleaning Damaged Condensation Coil Satisfactory Marginal Poor Insulation missing Leak/Oil present Damaged Refrigerant Lines Satisfactory Marginal Poor No P-Trap: install Condensate Lines/Drain Satisfactory Marginal Poor Recomment HVAC technician examine/clean/service Condition Did not operate due to temperature at or less than 60° Comments Boiler system X N/A Brand name: Approx. age: Model #: Serial #: LP Oil Electric Solid fuel Energy source Gas Hot water Baseboard Steam Radiator Radiant floor Distribution Pump Gravity Multiple zones Circulator Temp/pressure gauge exist: Yes No Operable: Yes No Controls Yes No Oil fired units Disconnect: Yes No N/A Combustion air venting present Yes No Missing Extension proper: Yes No Recommend repair/replace Relief valve When turned on by thermostat: Fired Did not fire Operated Satisfactory: Yes No Recommend HVAC technician examine before closing Operation Comments General Other systems Type X N/A Electric baseboard Radiant ceiling cable Gas space heater Solid fuel burning stove This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 39 A/C Condenser Cooling System Other systems cont. Yes No Proper operation Satisfactory System condition Comments Marginal Poor Recommend HVAC Technician Examine This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 40 Combo Unit - A/C-Heat System 1 Heating system Brand name: Unit #1 Approx. age: Unknown/Could not read label Model #: Serial #: Satisfactory Marginal Poor Disconnect Installed: Yes No Disconnect Meanns: Pull-Out Breaker/Fuse Wiring Exposed / Need Repair Safey Hazard Max Fuse Size: Size Breaker/Fuse installed: Recommended HVAC technician examine None Unit #2 Brand name: Approx. age: Unknown/Could not read label Model #: Serial #: Satisfactory Marginal Poor Disconnect Installed: Yes No Disconnect Means: Pull-Out Breaker/Fuse Wiring Exposed / Need Repair Safety Hazard Max Fuse Size: Size Breaker/Fuse installed: Wiring Exposed / Need Repair Natural Gas LP Oil Solid fuel Energy source Electric Central system Floor/wall furnace Direct drive Belt drive Gravity Warm air system N/A Sealed Not Visible Visual w/mirror Flame distortion Rusted Heat exchanger Carbon/soot buildup N/A Detected at plenum Detected at register Not tested Carbon monoxide Tester: N/A Yes No Combustion air venting present Disconnect: Yes No Normal operating and safety controls observed Controls Gas shut off valve: Yes No Recommend installing gas shut off valve Metal duct Insulated flex duct Cold air returns Duct board Asbestos-like wrap Distribution Safety Hazard N/A Satisfactory Rusted Improper slope Safety hazard Recommend repair/replace Flue piping Standard Electrostatic Satisfactory Needs cleaning/replacement Missing Filter Electronic (not tested) Fired Did not fire Proper operation: Yes No Not tested When turned on by thermostat N/A Supplemental electric Supplemental gas Heat pump N/A Satisfactory Marginal Poor Water/Sand Observed: Yes No Sub-slab ducts N/A Exterior temperature Other System not operated due to Comments This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 41 Combo Unit - A/C-Heat System 2 Heating system Brand name: Unit #1 Approx. age: Unknown/Could not read label Model #: Serial #: Satisfactory Marginal Poor Disconnect Installed: Yes No Disconnect Meanns: Pull-Out Breaker/Fuse Wiring Exposed / Need Repair Safey Hazard Max Fuse Size: Size Breaker/Fuse installed: Recommended HVAC technician examine None Unit #2 Brand name: Approx. age: Unknown/Could not read label Model #: Serial #: Satisfactory Marginal Poor Disconnect Installed: Yes No Disconnect Means: Pull-Out Breaker/Fuse Wiring Exposed / Need Repair Safety Hazard Max Fuse Size: Size Breaker/Fuse installed: Wiring Exposed / Need Repair Natural Gas LP Oil Solid fuel Energy source Electric Central system Floor/wall furnace Direct drive Belt drive Gravity Warm air system N/A Sealed Not Visible Visual w/mirror Flame distortion Rusted Heat exchanger Carbon/soot buildup N/A Detected at plenum Detected at register Not tested Carbon monoxide Tester: N/A Yes No Combustion air venting present Disconnect: Yes No Normal operating and safety controls observed Controls Gas shut off valve: Yes No Recommend installing gas shut off valve Metal duct Insulated flex duct Cold air returns Duct board Asbestos-like wrap Distribution Safety Hazard N/A Satisfactory Rusted Improper slope Safety hazard Recommend repair/replace Flue piping Standard Electrostatic Satisfactory Needs cleaning/replacement Missing Filter Electronic (not tested) Fired Did not fire Proper operation: Yes No Not tested When turned on by thermostat N/A Supplemental electric Supplemental gas Heat pump N/A Satisfactory Marginal Poor Water/Sand Observed: Yes No Sub-slab ducts N/A Exterior temperature Other System not operated due to Comments This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 42 Electric System Main panel Location Condition Exterior wall X Satisfactory Marginal Poor Signs of moisture intrustion causing rusting Enclosure damaged: repair/replace Recommend licensed electrical technician to evaluate Unknown 60a 100a X 200a 400a 120v/240v Service (Main) - Amperage/Voltage 100a (Overhead Service) 200a OverHead Service X Undergroud Service 200a Over Current Device: X Breaker Fuse Multiple tapping of Main Disconnect N/G clearance from residential property (including windows) to OH Service: Recommend Safety Hazard Location?: N/G Clearance from ground/roof to OH Service, Reommend contacting Utility Company Safety Hazard Location?: No - Clearance should be: 30" wide & 36" in front Adequate Clearance to Panel X Yes X Satisfactory Marginal Poor Open Grounds, where?: Reverse Polarity, where?: Electrical Fixtures GFCI not operation, where?: Ungrounded 3-prong outlets, where?: Missing GFCI protection, where?: Recommend a licensed electrician to evaluate: X Copper X Aluminum Solid Branch Aluminum Wiring Not Visible X Romex BX Cable Branch wire Conduit Knob & Tube Multiple breaker/fuse tapping Branch circuit undersized Comments No Electric Panel: Breakers Labled X Breakers Labeled X Yes Recommend Labeling Circuirs on Electrical Panel Door Legend X ARCI Breakers X Breakers Breaker(s) Off When Opened Panel Door How many?: Other Breakers GFCI Breakers in panel: Yes X No Operated X Panel is full, no available breaker spaces Neutral Bar Grounding Screw or Bonding Strap Missing: Install Grounding / Bonding X Satisfactory: Grounding Electrode Conductor Ground Rod visible: X Yes No Signs of physical conductor damage/loose Loose conductor at ground rod/clamp Improper/missing - nipple/enclosure/netural bar/ground bar bonding Plastic/Metal/Bond Bushing missing Recommend license electrical technician to evaluate Marginal Poor Panel Cover / Dead front X Satisfactory Dead Front cover missing/damaged/will not close Breaker Blanks missing/damaged: repair/install Dead Front cover missing mounting screews Recommend licensed electrical technician to evaluate Comments Sub Panel #1 Location Condition Satisfactory Marginal Poor Signs of moisture intrustion causing rusting Enclosure damaged: repair/replace Recommend licensed electrical technician to evaluate 120v/240v Over Current Device - Amperage/Voltage Over Current Device Amperage: Multiple tapping of line feeder Safety Hazard Yes No: Clearance should be: 30" wide & 36" in front Adequate Clearance to Sub Panel Reason: Copper Aluminum Solid Branch Aluminum Wiring Not Visible Romex BX Cable Branch wire Conduit Knob & Tube Multiple breaker/fuse tapping Branch circuit undersized Comments Breakers Labeled Yes No Sub Panel: Breakers Labled Recommend Labeling Circuirs on Electrical Panel Door Legend ARCI Breakers Breakers Breaker(s) Off When Opened Panel Door How many?: Other Breakers GFCI Breakers in panel: Yes No Operated Panel is full, no available breaker spaces Yes No Isolate/Separate Grounding / Bonding Neutral Conductors separated from Ground Conductors: Neutral Bar bonded to Enclosure: Remove Bonding Screw/Strap to isolate Grounding Bar needed: Install Grounding Bar Improper/missing - nipple/enclosure/ground bar bonding Plastic/Metal/Bond Bushing missing Recommend license electrical technician to evaluate Satisfactory Marginal Poor Panel Cover / Dead front This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors 1704 Stone Slate Road Bedrock, AL 12345 Page 43 Electric System Sub Panel #1 cont. Missing Damaged Will not latch Closed Repair Panel Cover / Dead front cont. Dead Front Cover: Breaker Blanks missing/damaged - repair/install Dead Front cover missing mounting screews - Add additional mounting screews Recommend licensed electrical technician to evaluate Comments Evaporator Coil Section Unit #1 X N/A Central system Wall unit General Location: Age: Satisfactory Not Visible Needs cleaning Damaged Evaporator coil Leak/Oil present Damage Insulation missing Satisfactory Refrigerant lines To exterior To pump Floor drain Other Condensate line/drain Yes No Needed: Yes No Primary pan appears clogged Secondary condensate line/drain Present: Recommend technician evaluate Differential: Operation Satisfactory Marginal Poor Recommend HVAC technician examine/clean/service Condition Not operated due to exterior temperature Comments Evaporator Coil Section Unit #2 X N/A Central system Wall unit General Location: Age: Satisfactory Not Visible Needs cleaning Damaged Evaporator coil Leak/Oil present Damage Insulation missing Satisfactory Refrigerant lines Recommend/Replace damaged/missing insulation To exterior To pump Floor drain Other Condensate line/drain Yes No Needed: Yes No Primary pan appears clogged Secondary condensate line/drain Present: Recommend technician evaluate Differential: Operation Satisfactory Marginal Poor Recommend HVAC technician examine/clean/service Condition Not operated due to exterior temperature Comments This confidential report is prepared exclusively for Fred & Wilma Flintstone © 2015 Majestic Home Inspectors