A7-1 Furniture Plan
Transcription
A7-1 Furniture Plan
1 2 3 4 5 6 BECK CHEVROLET BUICK GMC F Facility Image Renovations 1601 REID ST. PALATKA, FL 32177-3146 E PERMIT DOCUMENTS - 12/08/2011 rev 12/08/2011 D PROJECT NOTES: INDEX OF DRAWINGS GENERAL CVR Cover & Notes LS-1 Life Safety & Code C PROJECT LOCATION CIVIL C1.0 C2.0 Civil Demolition Plan Civil Site Plan EXISTING CONDITIONS EX-1 Existing Conditions Plans EX-2 Existing Conditions Elevations EX-3 Existing Conditions Sections ARCHITECTURAL D-1 Demolition Plan D-2 Demolition Elevations & Details A1-1 Floor Plan A1-2 Floor and Wall Finish Plan A1-3 Reflected Ceiling Plan A1-4 Insulation Plan and Roof Plan A2-1 Exterior Elevations A3-1 Building Sections A3-2 Wall Sections A3-3 Wall Sections A3-4 Wall Sections A3-5 Details A4-1 Interior Elevations, Details A5-1 Millwork Details A6-1 Door & Window Elevations A6-2 Door & Window Details A7-1 Furniture Plan B STRUCTURAL S1.01 Structural Notes and Schedules S1.02 Typical Foundation Details S1.03 Typical Structural Details S2.01 Foundation Plan S3.01 Roof Framing Plan Project Identification: Facility Image Renovations at 1601 REID ST. PALATKA, FL 32177-3146 for BECK CHEVROLET BUICK GMC Project Location: 1601 REID ST. PALATKA, FL 32177-3146 Date: BUILDING SYSTEMS M-1 Mechanical Equipment Schedule, Notes, Legend M-2 Mechanical Floor Plan - Demolition & Detail M-3 Mechanical Floor Plan P-1 P-2 P-3 E-1 E-2 E-3 E-4 Plumbing Schedule, Notes, Legend, Details Plumbing Floor Plan - Demolition Enlarged Plumbing Floor Plan Electrical Legend, Notes Abbreviations Electrical Legend, Notes - Demolition Electrical Legend, Notes - Lighting Electrical Floor Plan - Power & Systems S-T-R: 12-9-19 Rev: Tax Parcel ID: 14584-000-000 Date: 00/00/00 Owner: St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 Architect: Stephen D. Bender, AR94748, LEED AP & MW BENDER ARCHITECTURE, LLC. FL LIC# AA26001823 2631 NW 41st Street, Suite E-2 Gainesville, FL 32606 352-682-4986 p 866-317-2322 f stephen@mwbender.com http://mwbender.com/ Design info: Basic Wind Speed = 110 mph Enclosure Category = Fully enclosed Exposure Category = B Importance Factor = 1.0 Interior Pressure Coefficients = +0.18 / -0.18 See structural drawings for live and dead loads, components and cladding, etc Rev: Description: Date: 00/00/00 Rev: Description: Date: 00/00/00 Project Title: Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 Client Name: St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 Consultants: Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design GM Facility Image Identification: BAC #: Enterprise Name: 185162 PALATKA CBG, LLC Gensler #: 53.9300.472 4.0 DID Version: A Rev: stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D 1 SITE LOCATION Scale: 1 : as noted Sheet Description: N.T.S. Cover & Notes Sheet Number: CVR (C) 2011 MW Bender Architecture, LCC 1 2 3 4 5 6 WORK AREA WORK AREA EXIT 1 38 7.5" 114" F SALES OFFICE SALES OFFICE EXIT 5 7 1.3" 80" 002 003 AREA: 73 SF OCC: AREA: 147 SF OCC: F.E. SALES OFFICE 004 AREA: 73 SF OCC: TOOL ROOM T.D. = 97' 032 AREA: 156 SF OCC: PARTS INVENTORY TECHNICIAN LOCKER/ RESTROOM IT 006 AREA: 28 SF OCC: 029 AREA: 2753 SF OCC: 031 LEGEND OF SYMBOLS - LIFESAFETY SALES OFFICE 005 EXIT/STAIR NUMBER MUMBER OF OCCUPANTS EXITING EGRESS WIDTH REQ'D. - FBC TABLE 1004 EGRESS WIDTH PROVIDED EXIT 4 218 32.70" 36" AREA: 73 SF OCC: TECHNICIAN LOCKER/ RESTROOM E CONFERENCE/ TRAINING/ BREAK 030 007 AREA: 25 SF OCC: 008 AREA: 330 SF OCC: 680 SF/49 001 AREA: 3979 SF OCC: ROOM NAME ROOM NUMBER SQUARE FOOTAGE OF ROOM/ EGRESS OCCUPANCY NFPA 101 TABLE 7.3.3.1, FBC TABLE 1004 2 HR FIRE RATED SEPARATION EGRESS PATH EXIT FINANCE OFFICE 028 EGRESS PATH DIRECTION FIRE EXTINGUISHER LOCATION 009 AREA: 93 SF OCC: PARTS SALES 024 SALES OFFICE SALES OFFICE SALES OFFICE 016 015 014 AREA: 80 SF OCC: AREA: 204 SF OCC: F.E. SERVICE SALES FLOOR AREA: 67 SF OCC: FILE STORAGE AREA EXIT 4 7 1.3" 36" SALES OFFICE T.D. = 122' AREA: 25 SF OCC: AREA: 80 SF OCC: SALES OFFICE SALES OFFICE 013 012 AREA: 80 SF OCC: AREA: 80 SF OCC: AREA: 107 SF OCC: F.E. KEYS 011 FIRE HOSE CABINET/FIRE DEPARTMENT CONNECTION AREA: 12 SF OCC: AREA: 80 SF OCC: JANITOR T.D. = 100' RETAIL PARTS DISPLAY AREA: 14 SF OCC: HALL ELECTRICAL ROOM EMERGENCY ELECTRICAL ROOM ELEVATOR MACHINE ROOM E EE EMR 010 017 TOTAL DISTANCE TO EXIT T.D. = AREA: 280 SF OCC: 023 033 WOMENS AREA: 127 SF OCC: AREA: 1440391 SF OCC: CASIER 025 D AREA: 105 SF OCC: TOTAL OCCUPANCY OF AFFECTED EGRESS AREAS 019 REFRESHMENTS/ HOSPITALITY AREA 022 DEALERS OFFICE 021 AREA: 157 SF OCC: RR HALL 034 as calculated on a per space basis 135 018 AREA: 39 SF OCC: AREA: 101 SF OCC: AREA: 311 SF OCC: GSF TOTAL EGRESS AFFECTED AREA SF TOTAL WORK AREA SF MENS AREA: 435 SF OCC: 020 AREA: 160 SF OCC: SERVICE MANAGER EXIT ACCESS EXIT 2 61 12.2" 80" 026 AREA: 117 SF OCC: EXIT ZONE A EXIT ZONE B EXIT ZONE C 10290 Occupancy Calculated by GSF 102.9 8130 OCCUPANTS EXITS per ZONE 75 13 47 2 2 2 OCCUPANTS per EXIT 37.5 6.5 23.5 WORK AREA SERVICE WRITERS OFFICE EXITS 1 2 3 4 5 027 AREA: 278 SF OCC: F.E. existing egress door maintained OCCUPANTS INCHES OF per EXIT WIDTH REQ'D 38 8 61 12 5 24 7 1 7 1 EXIT 3 24 4.7" 36" C Rev: ROOM NAME MARK 001 SHOWROOM/SALES FLOOR 002 SALES OFFICE 003 SALES OFFICE 004 SALES OFFICE 005 SALES OFFICE 006 IT 007 CONFERENCE/TRAINING/BREAK 008 SALES OFFICE 009 F&I OFFICE 010 JANITOR 011 KEYS 018 HALL 019 WOMEN'S RESTROOM 020 MEN'S RESTROOM EXIT ZONE A A WORK AREA B 3979 73 147 73 73 28 330 67 107 14 12 101 157 160 OCCUPANY/ sf 100 100 100 100 100 300 15 100 100 300 300 100 100 100 OCCUPANCY per SPACE 40 1 2 1 1 0 22 1 2 0 0 1 2 2 75 Date: Rev: Date: 00/00/00 Rev: Description: Date: 00/00/00 Rev: Description: Date: 00/00/00 Project Title: Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 Client Name: 1 LIFE SAFETY PLAN 3/32" = 1'-0" CODE NOTES: SUMMARY OF WORK: In general, the work consists of selective renovations to 8200 square feet (32%) of an existing 25,800 sf pre-engineered metal building construction plus an addition of 2300sf in the form of a service delivery and new car canopy. Specifically: Renovations to 4900sf of existing interior space include changes to layout, new finishes and new mechanical systems, new lighting, renovation of men's and women's restrooms. Enclosure and improvement to additional 4100sf existing covered showroom including new storefront and entrance doors, new finishes, new HVAC, new lighting. Facade improvements and new "entry elements" (ACM panel facades and structure/substructure); access and accessibility improvements (new stairs, ramps and railings). 2010 2007 FLORIDA BUILDING CODE: EXISTING BUILDING, INCLUDING 2009 SUPPLEMENT A square feet Renovations and additions are designed to comply with 2007 Florida Building Code: Existing Building, Chapter 3 Prescriptive Compliance Method. There is no proposed change of occupancy. Additions or alterations of the building are deisgned to comply with the requirements of the Florida Building Code, Building, for new construction. Portions of the structure not altered and not affected by the alteration are not required to comply with the code requirements for a new structure. 2010 2007 FLORIDA BUILDING CODE: BUILDING, INCLUDING 2009 SUPPLEMENT REQUIRED SEPARATION OF OCCUPANCIES (HOURS) - TABLE 508.3.3 Occupancy Bb, F-1; no separation required. Existing Building does not require separation. MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT - TABLE 1004.1.1 Business areas: 100 gross Industrial areas: 100 gross Storage, stock, shipping areas: 300 gross EGRESS WIDTH PER OCCUPANT SERVED - TABLE 1005.1 Egress components; 0.2 inches per occupant EMERGENCY LIGHTING REQUIREMENTS - TABLE 1006 Total Occupancy based on GSF of Business Area is 135 occupants. No emergency lighting required. Mixed occupancy, Nonseparated: 1006.1.1 Illumination of means of egress is provided. Factory Industrial F-1 Moderate-hazard Occupancy. No alterations in the area of this occupancy. 1006.3 Exit signs. Exits shall be marked by an approved sign readily visible from any direction of exit access. Exception: Main exterior exit doors that obviously and clearly are identifiable as exits. Existing Building CONSTRUCTION TYPE is Type III-B. Common path of egress travel - 1014.3. The common path of egress travel does not exceed 75 feet. CORRIDOR FIRE-RESISTANCE RATING - TABLE 1017.1 B, F corridors serving greater than 30 occupants, without sprinkler system 1 hour. Actual corridors serve less than 30 occupants. 1017.2 Corridor width. The minimum corridor width is greater than 44 inches. 1017.3 Dead ends. There are no dead ends corridors more than 20 feet in length. MINIMUM NUMBER OF EXITS FOR OCCUPANT LOAD - TABLE 1019.1 OCCUPANT LOAD of 1-500 persons per story, MINIMUM NUMBER OF EXITS, 2 per story. 5 exits provided. Renovated buildings is designed to meet the efficiencies listed on Form 400B for components being changed or complies with the envelope or systems criteria in Method B of EnergyGauge Summit-Fla/Com for the components being changed. St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 029 024 B PARTS INVENTORY PARTS SALES EXIT ZONE B 2990 204 300 100 10 3 13 012 013 014 015 016 017 021 80 80 80 80 80 280 311 100 100 100 100 100 100 100 1 1 1 1 1 3 4 022 023 025 026 C SALES OFFICE SALES OFFICE SALES OFFICE SALES OFFICE SALES OFFICE HALL GENERAL MANAGER OFFICE REFRESHMENTS & HOSPITALITY AREA RETAIL PARTS DISPLAY CASHIER SERVICE MANAGER EXIT ZONE C 435 127 105 117 15 100 100 100 29 2 2 2 47 028 FILE STORAGE NIC 300 existing egress 030 TECH/ R.R./ LOCKER NIC 300 existing egress Sheet Size: D 031 TECH/ R.R./ LOCKER NIC 300 existing egress Sheet Description: 033 SERVICE BAYS NIC 300 existing egress 034 035 036 RR SERVICE LANE NEW CAR DELIVERY NIC EXTERIOR EXTERIOR 300 existing egress Consultants: Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Scale: 1 : as noted Life Safety & Code NA NA Sheet Number: ALLOWABLE HEIGHT AND BUILDING AREAS - TABLE 503 EXIT ACCESS TRAVEL DISTANCE WITHOUT SPRINKLER SYSTEM - TABLE 1016.1: F-1 & B, 200 feet. Actual travel distance < 200 feet. LS-1 (C) 2011 MW Bender Architecture, LCC 1 2 3 211'-4" 55'-0" 14'-4" 4 AS BE PHA LO LT W 8" FF 18'-5" 6'-4" 5 6 WALL LEGEND EXISTING CMU WALL EXTERIOR WALLS 10' A.F.F. INTERIOR WALLS 8' UNO (SEE 8/EX) " 18 T L A FF PH W S A LO BE 44'-4" 10'-6" " 24 K L A W FF E D W SI ELO B F EXISTING CMU WALL WITH BRICK VENEER EXISTING LGMF WALL KEYED NOTES E01 E08 20'-7" 19'-11" STOR. E02 E03 E04 E05 E06 E07 E08 E09 E10 E11 SALES MGR. STOR. E12 SALES SPECIAL TOOLS E09 16'-0" E10 44'-10" PARTS STORAGE E10 SALES E11 GENERAL NOTES: E09 T. E E12 " 24 K L A W FF DE OW I S EL B E03 E02 BREAK ROOM T. SALES COVERED DISPLAY AREA 37'-2" E09 4 80'-2" E08 E07 16'-2" MULTI-USE 27'-5" 14'-9" 9'-11" 23'-2" 4'-0" E11 6'-3" E01 E11 E09 SALES AREA 10'-9" E08 F&I RETAIL PARTS OFFICE E09 E08 E08 LOCATION OF EXISTING TELEPHONE EQUIPMENT LOCATION OF EXISTING DATA EQUIPMENT BRICK VENEER PAINTED STUCCO ON BLOCK EIFS RIBBED METAL WALL PANELS TERRAZZO FLOORING CARPET FLOORING CERAMIC TILE FLOORING CONCRETE FLOORING DASHED LINE INDICATES MECHANICAL MEZZANINE ABOVE CMU WALL HEIGHT FOLLOWS SLOPE OF ROOF ABOVE EX3.0 EX-1 Existing Conditions Plans These drawings contain general information about the configuration of the existing building and it's construction. They have been made using direct observation of the conditions however, they are not as-built documents. EX-2 Existing Conditions Elevations These drawings contain general information about the configuration of the existing building and it's construction. They have been made using direct observation of the conditions however, they are not as-built documents. EX-3 Existing Conditions Sections These drawings contain general information about the configuration of the existing building and it's construction. They have been made using direct observation of the conditions however, they are not as-built documents. E03 D HALL E09 11'-8" 6'-4" 18'-11" 4'-8" 6'-2" E11 6'-10" E09 16'-8" 4'-3" 11'-11" SERVICE WOMEN E10 E12 E09 17'-9" 14'-11" SERVICE MGR. E09 E01 DEALER J E08 SALES MGR. E08 MEN E09 E11 13'-3" CASHIER E08 VEND AS BE PHA LO LT W FF 8 " E09 24'-0" C AS BE PHA LO LT W FF 24" AS BE PHA LO LT W FF 12" 13'-3" Rev: CUSTOMER LOUNGE SALES MGR Date: E11 Rev: E09 Date: 00/00/00 Rev: AS BE PHA LO LT W FF 8" Description: Date: 00/00/00 50'-9" Rev: 47'-10" Description: Date: 00/00/00 1 2 3 EX3.0 EX3.0 EX3.0 B Project Title: Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 Client Name: St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 Consultants: COVERED SERVICE AREA COVERED SERVICE AREA Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. A Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D Scale: 1 : as noted Sheet Description: Existing Conditions Plans 1 EXISTING CONDITIONS PLAN 1/8" = 1'-0" Sheet Number: EX-1 (C) 2011 MW Bender Architecture, LCC 1 2 3 4 5 6 F E06 E06 E04 E05 CHEVROLET BUICK E 1 EXISTING EAST ELEVATION 1/8" = 1'-0" E05 D BUICK 2 E04 E06 CHEVROLET EXISTING WEST ELEVATION 1/8" = 1'-0" E05 E06 E04 E05 E04 KEYED NOTES E01 BECK CHEVROLET C BUICK GMC E02 E03 E04 E05 E06 E07 E08 E09 E10 E11 LOCATION OF EXISTING TELEPHONE EQUIPMENT LOCATION OF EXISTING DATA EQUIPMENT BRICK VENEER PAINTED STUCCO ON BLOCK EIFS RIBBED METAL WALL PANELS TERRAZZO FLOORING CARPET FLOORING CERAMIC TILE FLOORING CONCRETE FLOORING DASHED LINE INDICATES MECHANICAL Rev: Date: Rev: Date: 00/00/00 Rev: Description: Date: 00/00/00 3 Rev: EXISTING NORTH ELEVATION Description: 1/8" = 1'-0" Date: 00/00/00 Project Title: E06 B E06 E05 Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 Client Name: St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 Consultants: Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design 4 A EXISTING SOUTH ELEVATION 1/8" = 1'-0" stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D Scale: 1 : as noted Sheet Description: Existing Conditions Elevations Sheet Number: EX-2 (C) 2011 MW Bender Architecture, LCC 1 2 3 4 5 0'-91 2" 6 cont. metal coping 5/8" exterior gypsum sheathing 0'-8" 5V-crimp backsheeting over plywood sheathing 4" LGMF stud framing 4" LGMF kicker 4'-0" 2" polystyrene foam with EIFS finish residential gutter F 12 2'-6" 1 0'-8" 2'-8" PEMB girt 1'-0" +/- 0'-31 2" E 6 6 EX3.0 sim to EX3.0 EIFS over lgmf column cover beyond 0'-8" 3'-5" 1'-1" EXISTING CROSS SECTION 1 3/16" = 1'-0" D 5 EXISTING SECTION BY COVERED DISPLAY 6 1/2" = 1'-0" EXISTING SECTION AT SERVICE 1/2" = 1'-0" 0'-91 2" cont. metal coping 5V-crimp backsheeting over plywood sheathing galvanized metal L4X2 roof panels L2X2 6 EX3.0 CUSTOMER LOUNGE VENDING HALL F&I PARTS PARTS 0'-4" 1'-1" 4" LGMF stud framing EXISTING CROSS SECTION 2 EXISTING 2X8 PT metal building brace 8" metal building purlin 5/8" exterior gypsum sheathing 3/16" = 1'-0" C metal building frame 2" polystyrene foam with EIFS finish Rev: Date: 8'-0" Rev: 1'-0" 5 5 EX3.0 sim to EX3.0 Date: 00/00/00 Rev: 1'-3" EXISTING CMU WALL EIFS over LGMF column cover beyond Description: Date: 00/00/00 Rev: Description: Date: 00/00/00 Project Title: Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 B EXISTING CROSS SECTION 3 3/16" = 1'-0" 7 EXISTING SECTION BY COVERED DISPLAY 1/2" = 1'-0" 8 EXISTING CMU PARTITION Client Name: St Johns Chevrolet-Buick-Pontiac-OldmobileWALL SECTION (TYP) GMC LCC. Break Sloan, General Manager 1/2" = 1'-0" 7 EX3.0 BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 Consultants: Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design mechanical mezzanine beyond suspended acoustical tile ceiling stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. A HALL 8'-0" 8'-0" SERVICE SALES COVERED DISPLAY AREA Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D Scale: 1 : as noted Sheet Description: Existing Conditions Sections 4 EXISTING TRANSVERSE SECTION 3/16" = 1'-0" Sheet Number: EX-3 (C) 2011 MW Bender Architecture, LCC 1 2 3 AS BE PHA LO LT W 8" FF REMOVE EXISTING AIR CONDITIONING EQUIPMENT - SEE MECHANICAL DEMOLITION PLAN 211'-4" 14'-4" 56'-9" 16'-8" 6'-4" 10'-6" 4 5 6 REMOVE CONCRETE RAMP GENERAL NOTES: " 18 44'-4" LT F A F PH W S O A EL B 1. 4" 2 K AL FF W DE W SI ELO B 2. F 3. STOR. 5. 6. 20'-7" 19'-11" STOR. 4. SALES MGR. 7. SPECIAL TOOLS SALES REMOVE EXISTING AIR CONDITIONING EQUIPMENT - SEE MECHANICAL DEMOLITION PLAN 44'-10" 16'-0" PARTS STORAGE " 24 K AL F W F E PROTECT ADJACENT W D SI ELO FLDOT RIGHT OF B WAY. PROVIDE TEMPORARY FENCE WITH VISUAL SCREENING. REMOVE LIGHT GAUGE PARTITIONS, DOORS, BORROWED LIGHTS, ELECTRICAL AND ALL ASSOCIATED CONSTRUCTION SALES T. E COORDINATE REMOVAL OF DATA EQUIPMENT WITH OWNERS' IT ADMINISTRATOR, MR. ANTHONY SARGENT (SARGE@BECKNISSAN.COM) BREAK ROOM REMOVE EXISTING ALUMINUM STOREFRONT T. SALES 10. 16'-2" F&I OFFICE 6'-2" 6'-10" RETAIL PARTS 11'-8" 6'-4" 18'-11" 16'-8" SERVICE AREA REMAINS IN OPERATION THROUGHOUT CONSTRUCTION. PROVIDE ADEQUATE SEPARATION BETWEEN THE WORK AND THE OWNER'S STAFF AND CLIENTS. MECHANICAL MEZZANINE TO BE DEMOLISHED IN AREA INDICATED BY DASHED LINE 4'-3" 11'-11" 17'-9" DEALER SALES MGR. J MEN REMOVE CONCRETE STAIR AND ALUMINUM HANDRAILS 14. Roof - maintain existing roof and maintain watertight structure throughout demolition. Care shall be taken during removal of exterior finishes that come into contact with existing flashing and gutters. Provide protection for existing roofing where conducting adjacent work. Roofing damaged by the contractor due to his negligence shall be replaced at his expense. Contractor shall be responsible for security of premises during demolition. Secure all openings during demolition. SAW-CUT AND REMOVE SLAB TO DEMOLISH EXISTING SANITARY PLUMBING AND REPLACE WITH NEW. AREA OF DEMOLITION INDICATED IN THE DRAWINGS IS DIAGRAMMATIC. COORDINATE ACTUAL EXTENT OF DEMOLITION WITH NEW CONSTRUCTION - SEE PLUMBING DRAWINGS REMOVE EXISTING WINDOW REMOVE EIFS STUCCO AND FOAM AT EACH COLUMN, TYP. 7'-0" 14'-11" 4'-6" 19'-6" CASHIER 13'-3" REMOVE LIGHT GAUGE FRAME PARTITIONS WHERE INDICATED WITH DASHED LINE DEMO CONCRETE IN HATCHED AREA WOMEN SERVICE MGR. 13. SALES AREA REMOVE CMU PARTITIONS IN LOCATIONS INDICATED (DASHED) 4'-8" 10'-9" 6'-3" D 12. 9'-11" 23'-2" 4'-0" 14'-9" 5'-3" 27'-5" 11. 80'-2" MECHANICAL MEZZANINE TO BE DEMOLISHED IN AREA INDICATED BY DASHED LINE 9. COVERED DISPLAY AREA 37'-2" MECHANICAL MEZZANINE TO REMAIN IN THIS AREA 8. The contractor shall be responsible for verifying all existing conditions in the field prior to any demolition. Any discrepancies relating to the drawings shall be reported to the architect immediately. Contractor shall be aware of selective demolition at any sections of work by reviewing all details to determine what is to be removed or to remain, and will be responsible for replacement in-kind of all work inadvertently removed. Coordinate demolition work with new architectural and structural work. Perform demolition only after coming to a complete understanding of construction that is to remain. Execute all demolition work in an orderly and careful manner with due consideration for areas to remain. Protect any existing utility lines active or not. Erect barricades and covers as necessary to protect pedestrians, workmen, trees, and adjacent properties from injury or damage. Erect barricades and covers as necessary to contain dust. At exterior demolition, periodically sprinkle to allay dust. The demolition contractor shall be responsible for preserving the integrity of all existing structural components and floor slabs to remain. Any components that are damaged by the demolition contractor due to his negligence shall be replaced at his expense. The contractor shall remove items to be demolished as indicated on the drawings with care being taken not to damage adjacent walls, ceilings, floors, finishes, and structural framing scheduled to remain. The contractor shall remove all existing interior surface treatments indicated for demolition to their full height up to structure, unless otherwise noted and/or detailed. Leave all newly exposed and/or adjacent surfaces smooth and clean for proper installation of new finishes. All materials or items removed under this contract, which are not salvaged or reused, shall become the property of the contractor and shall be promptly removed from the site and legally disposed of. Do not store such material or items on site or permit debris to accumulate. Upon completion of demolition work, the property and adjacent areas must be left clear of all debris and restored to the satisfaction of the architect and local authorities. Refer to notes or references on drawings or other contract documents for additional specific information or explanation VEND 13'-3" 24'-0" C AS BE PHA LO LT W FF 8" CUSTOMER LOUNGE REMOVE EXISTING AIR CONDITIONING EQUIPMENT - SEE MECHANICAL DEMOLITION PLAN REMOVE EXISTING DOOR, FRAME TO REMAIN AS BE PHA LO LT W 2 FF 4" AS BE PHA LO LT W 1 FF 2" REMOVE EXISTING WINDOW REMOVE CONCRETE CURB. COORDINATE WITH NEW CONSTRUCTION REMOVE DOOR AND FRAME REMOVE CONCRETE RAMP SALES MGR Rev: Date: Rev: Date: 00/00/00 Rev: AS BE PHA LO LT W 8 FF " Description: Date: 00/00/00 50'-9" 47'-10" Rev: Description: Date: 00/00/00 Project Title: Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 B Client Name: St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 Consultants: COVERED SERVICE AREA COVERED SERVICE AREA Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. A Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D Scale: 1 : as noted Sheet Description: Demolition Plan 1 DEMOLITION PLAN 1/8" = 1'-0" Sheet Number: D-1 (C) 2011 MW Bender Architecture, LCC 1 2 3 4 DEMOLISH EXISTING SERVICE WRITER STATIONS AND CANOPY 5 REMOVE DOOR AND FRAME, LANDING TO REMAIN REMOVE DOOR AND FRAME, CONCRETE LANDING AND STAIR REMOVE WINDOW 6 REMOVE EIFS AND EXTERIOR GYPSUM SHEATHING. LEAVE STUDS CLEAR OF FASTENERS REMOVE SIGNS AND RETURN TO OWNER, TYP. 5 D-2 F CHEVROLET REMOVE GLAZING AND STOREFRONT 1 REMOVE WINDOW REMOVE WINDOW DEMOLITION EAST ELEVATION BUICK SAW-CUT CMU MASONRY AND DEMOLISH AREA INDICATED TO PREPARE FOR NEW WINDOW REMOVE EIFS SURFACES AT EACH COLUMN, FRAMING TO REMAIN 1/8" = 1'-0" E 5 D-2 REMOVE EIFS AND EXTERIOR GYPSUM SHEATHING. LEAVE STUDS CLEAR OF FASTENERS BUICK REMOVE SIGNS AND RETURN TO OWNER, TYP. 0'-91 2" REMOVE DOOR AND FRAME CHEVROLET 4'-0" remove EIFS and exterior gypsum sheathing. leave studs clear of fasteners 1 REMOVE EIFS SURFACES AT EACH COLUMN, FRAMING TO REMAIN D 2 REMOVE WINDOW 12 REMOVE CONCRETE LANDING AND STAIR DEMOLITION WEST ELEVATION 1'-0" 1/8" = 1'-0" REMOVE SIGNS AND RETURN TO OWNER, TYP. 6 D-2 DEMOLISH EXISTING SERVICE WRITER STATIONS AND CANOPY REMOVE EIFS AND EXTERIOR GYPSUM SHEATHING. LEAVE STUDS CLEAR OF FASTENERS 0'-31 2" BECK CHEVROLET BUICK remove EIFS surfaces at each column, framing to remain GMC 3'-5" C 3 DEMOLITION NORTH ELEVATION 1/8" = 1'-0" REMOVE WINDOW REMOVE GLAZING AND STOREFRONT REMOVE WINDOW Rev: REMOVE EIFS SURFACES AT EACH COLUMN, FRAMING TO REMAIN Date: Rev: Date: 00/00/00 Rev: DEMOLISH EXISTING SERVICE WRITER STATIONS AND CANOPY 5 Description: Date: 00/00/00 DEMOLITION SECTION Rev: 1/2" = 1'-0" Description: Date: 00/00/00 Project Title: Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 0'-91 2" B remove metal coping remove 5V crimp backsheathing 4 DEMOLITION SOUTH ELEVATION Client Name: St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 Consultants: 1/8" = 1'-0" Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design 0'-4" 1'-1" remove EIFS and exterior gypsum sheathing. leave studs clear of fasteners stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. A Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D 1'-0" 1'-3" Scale: 1 : as noted Sheet Description: Demolition Elevations & Details 6 DEMOLITION SECTION 1/2" = 1'-0" Sheet Number: D-2 (C) 2011 MW Bender Architecture, LCC 2 3 4 1 GENERAL NOTES: A3-1 A3-2 NEW 4" CONCRETE SLAB FOR HVAC CU (SEE MECHANICAL PLANS) 1 A3-5 2. 49'-0" 2'-0" 72'-9" 17'-6" 1 1. PRE-ENGINEERED ENTRY ELEMENT 211'-4" 14'-4" 6 2 1 A3-1 F 5 8'-1" 2'-0" 2'-0" 18'-0" 16'-11" 2'-2" A3-5 3. 4 A3-5 9'-9" D DS E DS F 4. 5. 3'-5" A DS 0'-11" 1 10'-5" SALES OFFICE 9'-6" SALES OFFICE All elevations heights indicated are relative from finish floor elevations. Framing is dimensioned to the center of partitions and openings. Masonry is dimensioned to face of wall and edge of opening. All dimensions indicated 'clear' are to face of interior finish. Unless otherwise noted, door openings are 4" from nearest wall. See mechanical, plumbing and electrical drawings for layout of mechanical, electrical and communication rooms. 2 A3-5 2 20'-7" A3-5 SIM RELOCATE DATA EQUIPMENT (BY OWNER) SALES OFFICE SALES OFFICE KEYS 7'-11"+/- 21'-4" 8'-8" DEALERS OFFICE RR HALL DS I A3-5 PROVIDE BLOCKING FASTENED BETWEEN FRAMING, BEHIND DRYWALL FOR MOUNTING MEDIA WALL. COORDINATE LOCATION OF POWER, DATA AND CABLE. 1 A3-2 1 A3-5 SIM 9'-9" 8'-0" 2'-2" 18'-0" 2'-0" DS H SLOPE CONCRETE DOWN 1:12 0" 4'- 1 B Date: 2'-0" Rev: Date: 00/00/00 PIPE AND TUBE RAILINGS, TYP. Rev: Description: Date: 00/00/00 Rev: Description: Date: 00/00/00 A3-3 Project Title: 3'-4" 3'-4" 0'-9" NEW CONCRETE SHALL BE FLUSH WITH ASPHALT, TYP. 49'-0" 99'-1" Rev: O SL 3 50'-1" 16'-11" TE E 2 CR 1:1 N N CO OW PE D 2'-0" A3-2 25'-0" A3-5 SIM DS PRE-ENGINEERED ENTRY ELEMENT SERVICE WRITERS OFFICE 1 0'-0" 3'-5" J 3 24'-0" 13'-3" 5 A3-5 A B SERVICE MANAGER OFFICE 13'-7" A4-1 5 A3-5 4'-0" A4-1 3 FLUSH TRANSITION EQ. 8 3 A3-1 6'-10" MENS 47'-11" C A4-1 SLOPE CONCRETE DOWN 1/4" FOOT NEW CASHIER PASS-THRU WINDOW COUNTER (MILLWORK) - GR1 10'-10" 2 8'-7" A4-1 EQ. 9'-10" 5 CASHIER JAN. WOMENS VENDING REFRESHMENTS / HOSPITALITY AREA 7'-11"+/- 8'-0" HALL 24'-3" 17'-9" 11'-3" 10'-1" 11'-9" RETAIL PARTS DISPLAY COUNTER 8'-0" VENDING SERVICE 8'-0" 2'-6" 6'-5" 7 A4-1 NEW PARTS COUNTER (MILLWORK) - PL1 11'-5" 2'-0" SALES OFFICE 5'-11" SALES OFFICE PARTS SALES G A4-1 FINANCE OFFICE SALES OFFICE RETAIL PARTS DISPLAY 7'-7" 1 24'-6" FILE STORAGE AREA D SALES FLOOR SALES OFFICE CONFERENCE/ TRAINING/ BREAK 2 A3-3 3'-8" 31'-5" LOCATION OF NEW SUB-PANELS, SEE ELECTRICAL. MAINTAIN CLEAR FLOOR SPACE AS REQUIRED 10'-7" 6'-3" 23'-7" TECHNICIAN LOCKER / RESTROOM 4'-9" 7'-7" 80'-2" TECHNICIAN LOCKER / RESTROOM 73'-5" PARTS INVENTORY SALES OFFICE E/IT 5'-9" 44'-2" E 8'-6" TOOL ROOM 4'-11" 3'-0" 7'-11" 8'-4" SALES OFFICE Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 Client Name: St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 22'-0" 22'-0" 1 A3-4 SERVICE LANE 2 A3-4 44'-8" 2'-8" 44'-8" 2'-8" NEW CONCRETE DRIVE WITH APRONS, SEE CIVIL DRAWINGS 13'-5" 13'-5" NEW CAR DELIVERY 6 A3-4 4 3'-4" 3'-4" 3'-4" PROPOSED FLOOR PLAN stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D A3-4 1/8" = 1'-0" Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design A3-4 A 1 Consultants: 3 36'-4" 5 A3-4 Scale: 1 : as noted Sheet Description: Floor Plan 3'-4" Sheet Number: A1-1 (C) 2011 MW Bender Architecture, LCC 1 2 3 4 5 6 SALES OFFICE SALES OFFICE ACCENT COLOR EM1 12'-0" C1 C1 SALES OFFICE ACCENT COLOR TOOL ROOM 4'-6" F C1 ACCENT COLOR PARTS INVENTORY TECHNICIAN LOCKER / RESTROOM TECHNICIAN LOCKER / RESTROOM E/IT SALES OFFICE VCT1 C1 EQ. E ACCENT COLOR SALES FLOOR SALES OFFICE 192'-0" CONFERENCE/ TRAINING/ BREAK C1 RF1 ACCENT COLOR BACK WALL TYP. FILE STORAGE AREA D C1 VCT1 SALES OFFICE SALES OFFICE SALES OFFICE SALES OFFICE SALES OFFICE C1 C1 C1 C1 C1 PT1 2'-0" PT2 4'-0" TYPT FINANCE OFFICE 4'-0" TYPT ACCENT COLOR PARTS SALES JAN. EQ. KEYS HALL PT2 CF2 C1 CASHIER VENDING REFRESHMENTS / HOSPITALITY AREA VENDING SERVICE WOMENS PT2 DEALERS OFFICE RR HALL 8'-0" RR PT2 VCT1 MENS VCT1 4'-6" ACCENT COLOR PT2 RETAIL PARTS DISPLAY EM1 PT2 C SERVICE MANAGER OFFICE Rev: ACCENT COLOR VCT1 Date: Rev: Date: 00/00/00 SERVICE WRITERS OFFICE VCT1 Rev: Description: Date: 00/00/00 Rev: Description: Date: 00/00/00 Project Title: Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 B Client Name: SERVICE LANE EX1 St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 Consultants: Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design NEW CAR DELIVERY EX1 A stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D Scale: 1 : as noted Sheet Description: Floor and Wall Finish Plan 1 FLOOR FINISH PTLAN 1/8" = 1'-0" Sheet Number: A1-2 (C) 2011 MW Bender Architecture, LCC 1 2 3 4 5 6 ALUMINUM CANOPY LOUVERED SUNSHADE LOUVERED SUNSHADE 23'-6" 0'-6" 6" LGMF PARTITION WITH 1/2" GWB EACH SIDE AND R-16 BATT INSUL EXTEND TO BOTTOM OF DECK (HEIGHT VARIES). BRACE TO PURLINS 0'-6" F 0'-6" E 0'-6" EXISTING MECHANICAL MEZZANINE ABOVE 2'-0" 2'-0" 0'-6" 2'-0" 0'-6" 2'-0" 0'-6" 22'-6" 20'-0" 0'-6" D ALCOVE FOR LIGHTING (SEE RESTROOM DETAILS) LOUVERED SUNSHADE ALUMINUM CANOPY LOUVERED SUNSHADE ACRYLIC STUCCO ON DENS-GLASS C Rev: Date: Rev: Date: 00/00/00 Rev: Description: Date: 00/00/00 Rev: Description: Date: 00/00/00 Project Title: Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 B Client Name: St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 Consultants: Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. A Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D Scale: 1 : as noted Sheet Description: Reflected Ceiling Plan 1 REFLECTED CEILING PLAN 1/8" = 1'-0" Sheet Number: A1-3 (C) 2011 MW Bender Architecture, LCC 1 2 3 4 PROVIDE POLYISO BOARD INSULATION ON EXISTING EXTERIOR CMU WALLS, TYP. ADD FACED R-19 MBI ABOVE CMU (10'-0" AFF) TO EAVE (12'-0" AFF), TYP. 5 6 PROVIDE R-19 MBI ABOVE NEW WINDOW HEAD (9'-0" AFF) TO EAVE (12'-0"AFF),TYP. F 6" LGMF PARTITION WITH 1/2" GWB EACH SIDE AND R-19 BATT INSUL EXTEND TO BOTTOM OF DECK (HEIGHT VARIES). BRACE TO PURLINS PROVIDE R-19 MBI ABOVE NEW WINDOW HEAD (9'-0" AFF) TO RAKE (12'-0"AFF AT EAVE, 14'-0" AFF. AT RIDGE),TYP. E NO EXISTING INSULATION HERE. INSTALL MBI R-25 PLUS R-13: INSTALL UNFACED R-25 BETWEEN PURLINS; HOLD IN PLACE WITH TIE WIRE. INSTALL FACED R-13 UNDERNEATH PURLINS; HOLD IN PLACE WITH BANDS. D ADD R-13 UNFACED BATT INSULATION TO EXISTING MBI AT THIS WALL, SILL TO RAKE PROVIDE POLYISO BOARD INSULATION ON EXISTING EXTERIOR CMU WALLS, TYP. ADD FACED R-19 MBI ABOVE CMU (10'-0" AFF) TO EAVE (12'-0" AFF), TYP. ADD R-13 UNFACED BATT INSULATION TO EXISTING MBI AT THIS WALL, SILL TO RAKE PROVIDE R-19 MBI ABOVE NEW WINDOW HEAD (9'-0" AFF) TO EAVE (12'-0"AFF),TYP. EXISTING 6" THICK VINYL FACED R-19 MBI TO REMAIN, ADD 8" THICK MBI R-25 BETWEEN PURLINS; HOLD IN PLACE WITH BANDS PRE-ENGINEERED ENTRY ELEMENT LOUVERED SUNSHADE PARAPET WALL 2 INSULATION PLAN NEW RAIN GUTTER 82'-5" EXISTING SLOPE 1"/12" C MAINTAIN EXISTING GUTTER, CUT AT LOCATION OF NEW CONSTRUCTION AND PROVIDE NEW END. RELOCATE DOWNSPOUT. 56'-10" 1/16" = 1'-0" MAINTAIN EXISTING GUTTER 121'-1" EXISTING SLOPE 1"/12" Date: 00/00/00 EXISTING SLOPE 1"/12" Rev: NEW RAIN GUTTER 99'-7" PARAPET WALL LOUVERED SUNSHADE MAINTAIN EXISTING GUTTER 161'-4" PRE-ENGINEERED ENTRY ELEMENT 4" ROOF DRAIN, CONNECT TO 4" PVC RAINWATER LEADER CHASED THRU COLUMN AS INDICATED IN PLAN, TYP. 4"X3" OVERFLOW SCUPPER, SET 4" ABOVE LOWEST POINT OF ROOF; 4" TALL HEAD X 4 INCH WIDE WEIR Description: Date: 00/00/00 Rev: Description: Date: 00/00/00 Project Title: Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 Client Name: PARAPET WALL A Date: Rev: EXISTING SLOPE 1"/12" B Rev: PARAPET WALL SLOPE 1/4"/12" PARAPET WALL ALL 4 SIDES St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 Consultants: Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D Scale: 1 : as noted Sheet Description: Insulation Plan and Roof Plan 2 ROOF PLAN 1/16" = 1'-0" Sheet Number: A1-4 (C) 2011 MW Bender Architecture, LCC 1 2 3 4 5 6 ENTRY ELEMENT (30' WIDE X 23' HIGH) DEALER SIGN BUICK TRI-SHIELD GMC SIGNATURE F 5 EQ. PANELS 36'-0" 11 EQ. PANELS 99'-10" 3'-8" 3 EQ. PANELS 5'-0" 3'-8" E 1 EAST ELEVATION 1/8" = 1'-0" GMC SIGNATURE BUICK TRI-SHIELD ENTRY ELEMENT (30' WIDE X 23' HIGH) DEALER SIGN 9 EQ. PANELS 83'-3" D 2 WEST ELEVATION 1/8" = 1'-0" ENTRY ELEMENT (30' WIDE X 23' HIGH) ENTRY ELEMENT (30' WIDE X 23' HIGH) SERVICE SIGN C 3'-8" 2 EQ. PANELS 13'-1" 3'-0" 3 EQ. PANELS 21'-8" 3'-8" 3 EQ. PANELS 23'-3" 8 EQ. PANELS 81'-7" Rev: 5'-0" Date: Rev: Date: 00/00/00 3 EQ. PANELS Rev: Description: Date: 00/00/00 Rev: Description: Date: 00/00/00 Project Title: Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 B 3 NORTH ELEVATION 1/8" = 1'-0" ENTRY ELEMENT (30' WIDE X 28' HIGH) Client Name: St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 Consultants: Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. A Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D Scale: 1 : as noted Sheet Description: Exterior Elevations 4 SOUTH ELEVATION 1/8" = 1'-0" Sheet Number: A2-1 (C) 2011 MW Bender Architecture, LCC 1 2 3 4 5 6 0'-6" TYP F E 1 REFRESHMENTS/ HOSPITALITY AREA RETAIL PARTS DISPLAY 8'-0" SERVICE WRITERS OFFICE SALES OFFICE PARTS INVENTORY CROSS SECTION - PARTS 3/16" = 1'-0" ENTRY ELEMENT LOUVERED SUNSHADE PAREPET WALL D OPEN SALES FLOOR 11'-0" 7'-3" 9'-0" 10'-10" TYP. ACT CEILING OPEN C 2 Rev: CROSS SECTION - SHOWROOM 3-16" = 1'-0" Date: Rev: Date: 00/00/00 Rev: Description: MBI R-25 PLUS R-13 Date: 00/00/00 Rev: Description: Date: 00/00/00 Project Title: 0'-9" Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 3 A TRANSVERSE SECTION 3-16" = 1'-0" HALL SALES FLOOR 11'-0" Client Name: 7'-3" SERVICE 8'-0" B St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 Consultants: Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D Scale: 1 : as noted Sheet Description: Building Sections Sheet Number: A3-1 (C) 2011 MW Bender Architecture, LCC 3 5 TOP of Parapet ELEV. = 17'-0" TOP of Parapet ELEV. = 17'-0" F ACM manufacturer standard parapet detail (panel acts as coping) new closure strip ACM panel color indicated on elevation new LGMF framing (see structural) new sheathing (see structural) ACM panels insatalled with manufacturer's standard "rainscreen" details new metal backsheeting (profiled metal panel) new Weather Barrier Membrane with sealant, flashing and seal tape to comply with manufacturer's installation instructions. new sheathing (see structural) new metal backsheeting (profiled metal panel) new metal flashing lap min. 12" up vertical surface of new parapet and min. 4" into existing gutter ACM manufacturers typical horizontal panel joint, spacing indicated on elevations existing metal panel roofing system new closure strip new LGMF framing (see structural) new sheathing (see structural) new metal backsheeting (profiled metal panel) new metal panel termination profile with flashing new metal panel termination profile with flashing new metal flashing lap min. 8" up vertical surface of new parapet existing metal panel roofing system existing metal building purlin remove existing metal building rake fascia to install new lgmf wall framing existing metal building rake angle remove existing metal building fascia retainer clip to install new LGMF wall framing existing metal panel roofing system RAKE ELEV. VARIES = (~12'-0" to ~14'-0") existing metal building purlin existing metal building purlin new sheathing - see structural 3'-4" 2 PEMB Eave ELEV. = 12'-0" A3-2 A3-2 steel angle support for gutter steel angle support for gutter remove existing sheet metal fascia remove existing sheet metal fascia 8" thick metal building insulation between purlins (r-30) + 4" thick fibergalss batt insulation across purlins (r-11) 1'-0" Weather Barrier Membrane with sealant, flashing and seal tape to comply with manuf. installation instructions, installed continuous across new insulation D 8" thick metal building insulation between purlins (r-30) + 4" thick fibergalss batt insulation across purlins (r-11) new sheathing and new Weather Barrier Membrane with sealant, flashing and seal tape to comply with manufacturer's installation instructions, over new LGMF infill existing metal building z-girt Weather Barrier Membrane with sealant, flashing and seal tape to comply with manuf. installation instructions, installed continuous across new insulation 1'-0" new sheathing and new Weather Barrier Membrane with sealant, flashing and seal tape to comply with manufacturer's installation instructions, over new LGMF infill ACM manufacturers typical horizontal panel joint, spacing indicated on elevations 2 3'-103 4" 3'-4" new LGMF framing (see structural) new Weather Barrier Membrane with sealant, flashing and seal tape to comply with manufacturer's installation instructions. new sheathing - see structural PEMB Eave ELEV. = 12'-0" new closure strip ACM panels insatalled with manufacturer's standard "rainscreen" details new metal panel termination profile with flashing E ACM manufacturer standard parapet detail (panel acts as coping) ACM panel color indicated on elevation new metal flashing lap min. 12" up vertical surface of new parapet and min. 4" into existing gutter ACM manufacturers typical horizontal panel joint, spacing indicated on elevations ACM manufacturer standard parapet detail (panel acts as coping) ACM manufacturer standard parapet detail (panel acts as coping) 3'-4" ACM reference dimension 3'-4" ACM reference dimension ACM manufacturer standard parapet detail (panel acts as coping) 6 0'-41 4" TOP of Parapet ELEV. = 17'-0" 4 4'-73 4" 2 0'-41 4" 0'-41 4" 1 ACM manufacturers typical horizontal panel joint, spacing indicated on elevations existing metal building c-girt existing metal building c-girt ACM manufacturers typical soffit detail ACM manufacturers typical soffit panel joint ACM panel color indicated on elevation ceiling as scheduled ceiling as scheduled existing metal building profiled metal wall panel 1/2" GWB 1/2" GWB ACM panels insatalled with manufacturer's standard "rainscreen" details ACM manufacturers typical abutement detail new rigid board insulation: 1.5" thick XPS Board Insulation between z-furring or, 3/4" thick Polyiso Board insulation installed over 7/8" hat channel C new Weather Barrier Membrane with sealant, flashing and seal tape to comply with manufacturer's installation instructions. new rigid board insulation: 1.5" thick XPS Board Insulation between z-furring or, 3/4" thick Polyiso Board insulation installed over 7/8" hat channel ACM manufacturers typical horizontal panel joint, spacing indicated on elevations 3'-103 4" remove stucco and ~16" of 8" high cmu at PEMB frame lines to attach new parapet steel see structural new box gutter to replace existing Date: 0'-5" 0'-8" Rev: Rev: 0'-6" Date: 00/00/00 steel angle support for gutter Rev: Description: Date: 00/00/00 Rev: new sheathing - see structural existing 8" cmu wall with stucco (acrylic finish system) existing 8" cmu wall with stucco (acrylic finish system) B existng stem wall foundation actual construction below finish floor is unknown existing planting bed (+/- 12" below finished floor) TOP of Slab ELEV. = 0'-0" new LGMF studs screwed to metal building purlins and angles - see structural existing metal building profiled metal wall panel base as scheduled base as scheduled ACM manufacturer's standard base condition detail flooring as scheduled flooring as scheduled new steel angle fastenened to slab edge, cut or bend PEMB base trim to fit - see structural existing planting bed (+/- 12" below finished floor) existing metal building base of wall attachment (base angle, base trim and closure) ACM manufacturer's standard base condition detail TOP of Slab ELEV. = 0'-0" TOP of Slab ELEV. = 0'-0" 3'-103 4" BOX GUTTER DETAIL Description: Date: 00/00/00 Project Title: Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 Client Name: St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 Consultants: Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design existing asphalt (+/- 6" below finished floor) stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. existng stem wall foundation actual construction below finish floor is unknown A Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D Scale: 1 : as noted Sheet Description: Wall Sections 1 WALL SECTION AT ACM OVER CMU WALL 1" = 1'-0" 2 WALL SECTION AT ACM OVER CMU WALL WITH COLUMN 1" = 1'-0" 3 WALL SECTION AT ACM OVER METAL PANEL 1" = 1'-0" Sheet Number: A3-2 (C) 2011 MW Bender Architecture, LCC 2 3 4 5 6 0'-41 4" 1 ACM manufacturer standard parapet detail (panel acts as coping) new closure strip F 3'-4" ACM reference dimension ACM manufacturer standard parapet detail (panel acts as coping) new LGMF framing (see structural) ACM manufacturer standard parapet detail (panel acts as coping) ACM manufacturer standard parapet detail (panel acts as coping) new sheathing (see structural) new metal backsheeting (profiled metal panel) new closure strip ACM panel color indicated on elevation ACM panel color indicated on elevation new LGMF framing (see structural) ACM panels insatalled with manufacturer's standard "rainscreen" details new sheathing (see structural) new Weather Barrier Membrane with sealant, flashing and seal tape to comply with manufacturer's installation instructions. existing kicker ACM panels insatalled with manufacturer's standard "rainscreen" details new metal backsheeting (profiled metal panel) new Weather Barrier Membrane with sealant, flashing and seal tape to comply with manufacturer's installation instructions. new metal gutter ACM manufacturers typical horizontal panel joint, spacing indicated on elevations E ACM manufacturers typical horizontal panel joint, spacing indicated on elevations existing metal panel roofing system existing metal building purlin new sheathing - see structural new sheathing - see structural 3'-4" 2 A3-2 steel angle support for gutter 8"x6" steel tube 8" wf column @ 20' o.c. 1'-0" louver sunshade D 4'-2" 1'-1" ACM manufacturers typical soffit detail 0'-10" ACM manufacturers typical soffit panel joint ACM manufacturers typical abutement detail PRE-ENGINEERED ENTRY ELEMENT C 9'-0" 9'-0" 0'-8" Rev: Date: Rev: Date: 00/00/00 Rev: Description: Date: 00/00/00 Rev: Description: Date: 00/00/00 Project Title: Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 B Client Name: St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 Consultants: 2'-0" Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. A Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D Scale: 1 : as noted Sheet Description: Wall Sections 1 WALL SECTION - SHOWROOM 1" = 1'-0" 2 WALL SECTION - SHOWROOM 1" = 1'-0" Sheet Number: A3-3 (C) 2011 MW Bender Architecture, LCC 3 pre-engineered trusses -see structural 4 TOP of Parapet ELEV. = 17'-0" 6 ACM manufacturer standard parapet detail (panel acts as coping) ACM manufacturer standard parapet detail (panel acts as coping) ROOF SYSTEM manufacturer's standard parapet flashing detail ROOF SYSTEM manufacturer's standard parapet flashing detail F BOT Truss ELEV. = 13'-6" 5 ROOF SYSTEM over approved cover board and roof sheathing ROOF SYSTEM over approved cover board and roof sheathing TOP of Parapet ELEV. = 17'-0" TOP of Parapet ELEV. = 17'-0" TOP Truss ELEV. VARIES 0'-41 4" 2 0'-41 4" 1 TOP Truss ELEV. VARIES engineered lumber beam - see structural E engineered lumber beam - see structural engineered lumber beam - see structural TOP of Slab ELEV. = 0'-0" CROSS SECTION - SERVCE LGMF infill between top of CMU and bottom of truss 1/4" = 1'-0" acrylic stucco finish over fiber-reinforced gypsum sheathing ACM manufacturer standard parapet detail (panel acts as coping) ROOF SYSTEM manufacturer's overflow scupper detail ACM manufacturers typical sill detail ROOF SYSTEM over approved rigid insulation and cover board over roof sheathing TOP Truss ELEV. VARIES ACM manufacturers typical sill detail ACM manufacturers typical horizontal panel joint, spacing indicated on elevations 3'-912" D ACM manufacturers typical horizontal panel joint, spacing indicated on elevations ACM manufacturers typical horizontal panel joint, spacing indicated on elevations ACM manufacturers typical horizontal panel joint, spacing indicated on elevations ACM manufacturers typical horizontal panel joint, spacing indicated on elevations LGMF infill between top of CMU and bottom of truss C 3'-103 4" acrylic stucco finish over fiber-reinforced gypsum sheathing ACM manufacturers typical outside corner detail ACM panel color indicated on elevation ACM panel color indicated on elevation ACM panels insatalled with manufacturer's standard "rainscreen" details ACM panels insatalled with manufacturer's standard "rainscreen" details ACM panel color indicated on elevation ACM panels insatalled with manufacturer's standard "rainscreen" details ACM panels insatalled with manufacturer's standard "rainscreen" details 3'-103 4" ACM panel color indicated on elevation 3'-103 4" acrylic stucco finish over fiber-reinforced gypsum sheathing 3'-103 4" 1'-7" 4'-10" 3" PCV rainwater leader routed to southwest column, see plan 3'-103 4" ROOF SYSTEM approved tapered rigid insulation roof drain 3'-912" 0'-41 4" TOP of Parapet ELEV. = 17'-0" ACM manufacturers typical horizontal panel joint, spacing indicated on elevations 3'-103 4" 1 acrylic stucco finish over acrylic stucco finish over fiber-reinforced gypsum fiber-reinforced gypsum sheathing sheathing LGMF infill between top of LGMF of CMU infill and between bottom oftop truss CMU and bottom of truss acrylic stucco finish over acrylic stucco finish over fiber-reinforced gypsum fiber-reinforced gypsum sheathing sheathing 1'-7" acrylic stucco finish over fiber-reinforced gypsum sheathing BOT Truss ELEV. = x'-x" 1'-7" BOT Truss ELEV. = 13'-6" 4'-73 4" new concrete slab 4'-73 4" 12'-0" CMU column beyond Rev: Date: ACM manufacturers typical jamb detail PAREPET DETAIL - SERVCE Date: 00/00/00 1" = 1'-0" Rev: ACM manufacturer standard parapet detail (panel acts as coping) ROOF SYSTEM manufacturer's standard parapet flashing detail TOP of Parapet ELEV. = 17'-0" Project Title: 3'-103 4" B CMU - see structural CMU - see structural CMU - see structural CMU - see structural Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 3'-103 4" ROOF SYSTEM over approved cover board and roof sheathing TOP Truss ELEV. VARIES Description: Date: 00/00/00 3'-103 4" TOP Truss ELEV. VARIES Rev: ROOF SYSTEM manufacturer's standard parapet flashing detail 0'-41 4" 0'-41 4" TOP of Parapet ELEV. = 17'-0" ROOF SYSTEM over approved cover board and roof sheathing Description: Date: 00/00/00 ACM manufacturer standard parapet detail (panel acts as coping) 3'-103 4" 2 Rev: Client Name: St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 ACM manufacturer's standard base condition detail ACM manufacturer's standard base condition detail 4'-10" 4'-10" Consultants: BOT Truss ELEV. = 13'-6" PAREPET DETAIL - SERVCE 1" = 1'-0" 1'-7" acrylic stucco finish over fiber-reinforced gypsum sheathing acrylic stucco finish over fiber-reinforced gypsum sheathing acrylic stucco finish over fiber-reinforced gypsum sheathing 3 TOP of Slab ELEV. = 0'-0" LGMF infill between top of CMU and bottom of truss LGMF infill between top of CMU and bottom of truss A ACM manufacturer's standard base condition detail TOP of Slab ELEV. = 0'-0" 1'-7" acrylic stucco finish over fiber-reinforced gypsum sheathing ACM manufacturer's standard base condition detail ACM manufacturers typical outside corner detail ACM manufacturers typical outside corner detail ACM manufacturers typical jamb detail ACM manufacturers typical jamb detail 4 PAREPET DETAIL - SERVCE 1" = 1'-0" Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D Scale: 1 : as noted Sheet Description: Wall Sections 5 COLUMN SECTION - SERVCE 1" = 1'-0" 6 COLUMN SECTION - SERVCE 1" = 1'-0" Sheet Number: A3-4 (C) 2011 MW Bender Architecture, LCC 2 3 ACM manufacturers typical outside corner detail new WEATHER BARRIER MEMBRANE with sealant, flashing and seal tape to comply with manufacturer's installation instructions, over COLD-FORMED METAL FRAMING and SHEATHING; see structural drawings new 4" PVC DWV downspout bracket mounted to CMU wall provide 3/4" PT plywd panel to close bottom of framing F new steel column; see structural drawings ACM manufacturers typical abutment detail ACM manufacturers typical abutement detail new STOREFRONT window system 2'-1" edge of existing slab below 1/2" GWB 1/2" GWB Polyiso Board Insulation LGMF furring LGMF furring existing CMU wall with stucco finish ACM manufacturers typical abutement detail existing LGMF studs - assumed condition E edge of concrete landing below provide 3/4" PT plywd panel to close bottom of framing new 4" PVC DWV downspout bracket mounted to framing 2'-1" ACM manufacturers typical outside corner detail 1/2" GWB over existing LGMF studs new WEATHER BARRIER MEMBRANE with sealant, flashing and seal tape to comply with manufacturer's installation instructions, over COLD-FORMED METAL FRAMING and SHEATHING; see structural drawings +/- 0'-111 2" new WEATHER BARRIER MEMBRANE with sealant, flashing and seal tape to comply with manufacturer's installation instructions, over existing LGMF and new SHEATHING existing metal building frame LGMF furring new STOREFRONT window system ACM manufacturers typical jamb detail new steel column; see structural drawings new WEATHER BARRIER MEMBRANE with sealant, flashing and seal tape to comply with manufacturer's installation instructions, over COLD-FORMED METAL FRAMING and SHEATHING; see structural drawings provide 3/4" PT plywd panel to close bottom of framing new 4" PVC DWV downspout bracket mounted to CMU wall ACM manufacturers typical outside corner detail ACM DETAIL - PILASTER 6 0'-8" 1-1/2" = 1'-0" ACM manufacturers typical vertical joint detail new STOREFRONT window system D 1/2" GWB provide 3/4" PT plywd panel to close bottom of framing +/- 0'-8" new STOREFRONT window system 1-1/2" = 1'-0" edge of existing slab below 6 existing CMU wall with stucco finish ACM DETAIL - PILASTER ACM manufacturers typical jamb detail new WEATHER BARRIER MEMBRANE with sealant, flashing and seal tape to comply with manufacturer's installation instructions, over COLD-FORMED METAL FRAMING and SHEATHING; see structural drawings new 4" PVC DWV downspout bracket mounted to framing ACM manufacturers typical jamb detail 5 +/- 0'-111 2" 1 4 +/- 0'-111 2" 1 ACM manufacturers typical outside corner detail existing LGMF studs - assumed condition ACM manufacturers typical jamb detail new STOREFRONT window system existing metal building frame metal building insulation batts edge of existing slab below j-bead 1/2" GWB over existing LGMF studs 4 bottom of roof panel bottom of purlin 3-5/8" metal track ACM DETAIL -COLUMN WRAP existing cmu wall 1-1/2" = 1'-0" 1/2" gypsum wall board - one side or both sides as indicated in plan GWB with square or tapered edges, applied vertically or horizontally with vertical joints centered over studs. suspended acoustic ceiling system STOREFRONT sealant C 3-5/8" LGMF@ 16" o.c. 3-5/8" metal track 2 Rev: existing conc slab ACM DETAIL - COLUMN WRAP 1-1/2" = 1'-0" Rev: new STOREFRONT window system Date: 00/00/00 STOREFRONT sealant ACM manufacturers typical abutment detail 1/2" GWB over existing LGMF studs new WEATHER BARRIER MEMBRANE with sealant, flashing and seal tape to comply with manufacturer's installation instructions, over existing LGMF and new SHEATHING 1/2" GWB Polyiso Board Insulation existing metal building frame LGMF furring TYPICAL INTERIOR PARTITON - FULL HEIGHT 7 1-1/2" = 1'-0" bracing under roof purlins metal building insulation 0'-6" extend lgmf to under side of bracing under roof purlins new 4" PVC DWV downspout bracket mounted to CMU wall A 1'-10" ACM manufacturers typical inside corner joint existing metal building wall panel 3 ACM DETAIL - PILASTER 1-1/2" = 1'-0" ACM manufacturers typical abutement detail new WEATHER BARRIER MEMBRANE with sealant, flashing and seal tape to comply with manufacturer's installation instructions, over COLD-FORMED METAL FRAMING and SHEATHING; see structural drawings new STOREFRONT window system ACM manufacturers typical jamb detail ACM manufacturers typical vertical joint detail +/- 0'-111 2" +/- 0'-1112" new steel column; see structural drawings existing CMU wall with stucco finish 1/2" GYP. bd 2'-1" new 4" PVC DWV downspout bracket mounted to framing edge of concrete landing below Description: Date: 00/00/00 1/2" = 1'-0" Description: new WEATHER BARRIER MEMBRANE with sealant, flashing and seal tape to comply with manufacturer's installation instructions, over COLD-FORMED METAL FRAMING and SHEATHING; see structural drawings Project Title: Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 Client Name: St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 Consultants: suspended ceiling system 1/2" gwb provide 3/4" PT plywd panel to close bottom of framing Rev: Date: 00/00/00 B provide 3/4" PT plywd panel to close bottom of framing 9 GYPSUM WALL BOARD AT EXISTING CMU (TYP) Rev: existing LGMF studs - assumed condition new WEATHER BARRIER MEMBRANE with sealant, flashing and seal tape to comply with manufacturer's installation instructions, over COLD-FORMED METAL FRAMING and SHEATHING; see structural drawings Date: existing floor slab insulation 3-5/8" or 5-5/8" metal studs (see plan) metal track conc slab Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D ACM manufacturers typical outside corner detail Scale: 1 : as noted Sheet Description: 5 ACM DETAIL -COLUMN WRAP 1-1/2" = 1'-0" 8 TYPICAL INTERIOR PARTITON Details 1-1/2" = 1'-0" Sheet Number: A3-5 (C) 2011 MW Bender Architecture, LCC 3 4 5 0'-9" SALES FLOOR 6 0'-9" 2 2'-0" 1 OPEN 7'-3" HALL AT RESTROOMS 7'-0" F BORROWED LITE 1 SALES OFFICE OPEN OPEN ROAD GRAPHIC TYPICAL ADA RAMP AND RAILING DETAIL BORROWED LITE SALES FLOOR SOUTH WALL 6 N.T.S. 1/8" = 1'-0" HALL 7'-3" 6'-8" 8'-0" 0'-9" E BORROWED LITE (TYP) 2 SALES OFFICES AT HALL 1/8" = 1'-0" D ACT ceiling 0'-6" 1'-0" Lighting Alcove ELEV. = 9'-0" 3'-9" GWB Soffit and Cove 1'-0" Lighting Cove ELEV. = 9'-0" ACT Ceiling ELEV. = 8'-0" ACT Ceiling ELEV. = 8'-0" BOT of Soffit ELEV. = 7'-6" BOT of Soffit ELEV. = 7'-6" 6'-0" EQ. TOP of Counter ELEV. = 2'-6" 2'-0" 3'-01 2" 3'-01 2" 3 Vanity Base Tile Paper Towel (Folded) Dispenser: OFM TYPICAL RESTROOM ELEVATION 4 1/4" = 1'-0" Waste Receptacle WR1 Vanity Base Tile Toilet Tissue (Roll) Dispenser: OFM TYPICAL RESTROOM SECTION 1/4" = 1'-0" EQ. 7'-9" Paper Towel Dispenser: OFM 1'-6" Date: Paper Towel Dispenser: OFM Rev: Date: 00/00/00 Toilet Tissue (Roll) Dispenser: OFM 4'-7" Mirror Unit MU1 Sanitary-Napkin Disposal Unit SN1 TOP of Slab ELEV. = 0'-0" TOP of Slab ELEV. = 0'-0" 3'-6" Underlavatory Guard 0'-6" Sanitary-Napkin Disposal Unit SN1 Rev: 8'-012" 3'-3" 2'-10" Waste Receptacle WR1 3'-0" 3'-10" 1'-11" 1'-11" EQ. TOP of Counter ELEV. = 2'-6" C EQ. 2'-111 2" 5'-0" Diaper-Changing Station DC1 Paper Towel (Folded) Dispenser: OFM 1'-7" Rev: Description: Date: 00/00/00 Rev: Description: 0'-6" Grab Bar GB1 Date: 00/00/00 0'-6" 1'-0" 3'-0" Project Title: Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 3'-0" Grab Bar GB1 Client Name: 0'-6" 1'-6" 3'-3" 2'-10" 3'-0" 3'-6" Toilet Tissue (Roll) Dispenser: OFM VENDING 7'-11" Paper Towel Dispenser: OFM Toilet Tissue (Roll) Dispenser: OFM VENDING St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 38'-0" 4'-7" BOT of Soffit ELEV. = 7'-0" Paper Towel Dispenser: OFM Waste Receptacle WR1 1'-11" 3'-10" 1'-11" Mirror Unit MU1 3'-01 2" A 5 REFRESHMENTS/HOSPITALITY AREA 1/4" = 1'-0" SEE A5.1 FOR MILLWORK AND MATERIALS Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D Diaper-Changing Station DC1 REFRESHMENTS Consultants: stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. 3'-4" 3'-01 2" EQ. B EQ. ACT Ceiling ELEV. = 8'-0" 1'-0" Grab Bar GB1 EQ. CUSTOMER BUSINESS CENTER Scale: 1 : as noted Sheet Description: EQ. 6'-0" 7 ENLARGED RESTROOM PLAN NOTE: SECTION 10801 - TOILET AND BATH ACCESSORIES Interior Elevations, Details 1/2" = 1'-0" Sheet Number: A4-1 (C) 2011 MW Bender Architecture, LCC 1 2 3 4 5 6 5'-0" 0'-3" 0'-3" 1'-11" 0'-312" F 0'-3" 0'-312" 9'-10" 0'-3" 1'-11" 0'-6" 0'-10" 2'-9" 0'-6" 2'-9" 1'-5" 0'-10" scribe panel as necessary at lavatories 0'-8" ELEVATION 1 0'-6" 0'-6" 7'-21 2" 0'-6" 0'-6" E 0'-21 2" 6'-2" 6'-2" 8'-0" 5 EQUAL PANELS MONITOR SECTION ELEVATION MEDIA WALL 4 1/2"=1'-0" 0'-8" 0'-6" SECTION REST ROOMS 1/2"=1'-0" 0'-4" 2'-0" 0'-4" 0'-11 2" 2'-6" 2'-012" 0'-11 2" D C ELEVATION Rev: SECTION Date: 2 Rev: RETAIL PARTS COUNTER Date: 00/00/00 1/2"=1'-0" Rev: Description: Date: 00/00/00 1 2 3 4 3/4" MDF panels, edgebanded, with wall covering. 1" reveal typ. Rev: Description: Date: 00/00/00 4 Project Title: Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 B St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 2'-6" 2'-6" 2'-6" 2'-6" Client Name: Consultants: 1'-6" 1'-0" 2'-112" 2 0'-4" 3 Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. 2'-61 2" 0'-11 2" 0'-4" 3'-0" 2'-61 2" 0'-11 2" 2'-112" 7'-0" 1'-6" 7'-0" 3'-0" 2'-61 2" 0'-4" SECTIONS 1'-0" 0'-9" 1 ELEVATION 2'-11 2" 0'-11 2" 3'-0" 2'-0" 0'-4" 0'-11 2" A 1'-0" 1'-6" 2'-112" 0'-11 2" 0'-61 2" 3'-0" 7'-0" 1'-0" 1'-6" VENDING 7'-0" VENDING 4 Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D Scale: 1 : as noted Sheet Description: Millwork Details 3 REFRESHMENTS / BUSINESS CENTER 1/2"=1'-0" Sheet Number: A5-1 (C) 2011 MW Bender Architecture, LCC 1 EQ. 2 EQ. EQ. EQ. 3 EQ. EQ. EQ. EQ. EQ. 4 EQ. EQ. EQ. EQ. EQ. 5 6 EQ. 9'-0" F G STOREFRONT ELEVATION 1/4" = 1'-0" EQ. EQ. EQ. +/- 17'-9" 9'-9" EQ. +/- 7'-11" EQ. EQ. EQ. 2'-0" EQ. +/- 16'-81 4" E F STOREFRONT ELEVATI +/- 7'-11" EQ. EQ. +/- 17'-9" 6'-0" EQ. D 1/4" = 1'-0" EQ. EQ. EQ. EQ. +/- 16'-81 4" STOREFRONT EL 1/4" = 1'-0" EQ. EQ. 9'-0" 7'-0" 9'-0" 2'-0" D STOREFRONT ELEVATIO E 1/4" = 1'-0" EQ. 9'-0" 6'-9" 9'-0" 7'-0" 3'-0" J STOREFRONT EL I 1/4" = 1'-0" STOREFRONT ELEVATION H 1/4" = 1'-0" STOREFRONT ELEVATION 1/4" = 1'-0" 0'-4" 0'-6" 2'-8" 1'-0" 1'-8" or as sched. 1'-8" or as sched. 0'-8" CL 1'-0" 0'-8" 2'-0" 2'-6" C CL 0'-8" Rev: Date: Rev: Date: 00/00/00 1'-0" Rev: Description: Date: 00/00/00 Rev: Description: Date: 00/00/00 1'-0" Project Title: 1 B 1 3 2 Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 5 4 Client Name: HOLLOW METAL DOOR ELEVATIONS St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 1/2" = 1'-0" 11'-3" 4'-0" 3'-0" 0'-3" 0'-3" 4'-0" 4'-111 2" 3'-0" stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. 6'-9" 7'-3" 0'-3" Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design 6'-9" 7'-3" Consultants: A Drawn: rdh Date: Approved: sdb Date: 12/08/2011 0'-3" 0'-3" Sheet Size: D 3'-71 2" 0'-3" 2 FINANCE OFFICE ELEVATION 1/2" = 1'-0" 1 : as noted Sheet Description: Door & Window Elevations 3'-71 2" 0'-3" Scale: 3'-0" 0'-3" 0'-0" 0'-3" VARIES 0'-3" 3 0'-3" TYPICAL SALES OFFICE ELEVATION 1/2" = 1'-0" Sheet Number: A6-1 (C) 2011 MW Bender Architecture, LCC 1 2 0'-01 2" 0'-21 2" 4 5 6 0'-01 2" 1/2" GWB 1/2" GWB 0'-012" 6" metal stud 3-5/8 metal stud 0'-01 2" blocking 0'-21 2" F 3 0'-6" blocking hollow metal frame 0'-6" hollow metal frame 1 JAMB-BORROWED LITE HEAD-BORROWED LITE 2 3" = 1'-0" 3" = 1'-0" 0'-918" 0'-918" E cmu 1/2" GWB on 3/4" furring cmu 0'-012" TYP. 1/2" GWB on 3/4" furring sealant hollow metal frame 0'-2" 0'-2" D sealant 3 JAMB 0'-012" reno "butterfly" anchors 3 per jamb hollow metal 0'-01 2" TYP. frame 0'-115 16" TYP. 0'-818" HEAD 4 3" = 1'-0" 3" = 1'-0" 1/2" GWB C 0'-012" TYP. 3-5/8 metal stud sealant drywall anchors 3 per jamb Rev: Date: Rev: Date: 00/00/00 0'-2" 0'-2" hollow metal frame Rev: Description: SEE HEAD DETAIL 5 0'-012" Date: 00/00/00 0'-01 2" TYP. 0'-115 16" TYP. JAMB 6 3" = 1'-0" Rev: Description: Date: 00/00/00 0'-818" Project Title: Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 HEAD 3" = 1'-0" B Client Name: St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 Consultants: 0'-01 2" TYP. 1/2" GWB 3-5/8 metal stud sealant drywall anchors 3 per jamb stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. 0'-01 2" 0'-2" 0'-2" hollow metal frame A 0'-01 2" TYP. 0'-115 16" TYP. 7 JAMB 3" = 1'-0" 8 HEAD Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design 0'-57 8" Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D Scale: 1 : as noted Sheet Description: Door & Window Details 3" = 1'-0" Sheet Number: A6-2 (C) 2011 MW Bender Architecture, LCC 1 2 3 4 5 6 F SALES OFFICE TYPICAL SALES MANAGER STATION OFOI PRODUCT INFORMATION OFOI E SALES STATION TYPICAL PRODUCT INFORMATION OFOI FINANCE OFFICE TYPICAL SALES STATION TABLE SET TYPICAL CUSTOMER SEATING TYPICAL D CUSTOMER SEATING AND TABLES TYPICAL LOGO SCREEN OFOI SALES MANAGER STATION OFOI GREETER'S DESK (RECEPTION DESK) OFOI C Rev: Date: Rev: Date: 00/00/00 CUSTOMER BUSINESS CENTER SEATING TYPICAL Rev: Description: Date: 00/00/00 Rev: Description: Date: 00/00/00 Project Title: Facility Image Renovations BECK CHEVROLET BUICK GMC Enterprise Name: PALATKA CGB, LCC BAC #: 185162 B Client Name: St Johns Chevrolet-Buick-Pontiac-OldmobileGMC LCC. Break Sloan, General Manager BECK CHEVROLET BUICK GMC 1601 REID ST, PALATKA, FL 32177-3146 A 7'-0" OPEN 7'-3" SALES OFFICE OPEN BORROWED LITE Wayland Structural Engineering, Inc. Campbell Engineering of North Florida, Inc. Bob Harris Design 0'-9" SALES FLOOR 0'-9" HALL AT RESTROOMS 2'-0" Consultants: OPEN ROAD GRAPHIC BORROWED LITE stephen bender, RA, LEEDAP 4011 NW 43ST Street, STE B GAINESVILLE, FL 32606 v 352-682-4986 f 866-317-2322 Upon acceptance into contract documents this drawing stephen@mwbender.com supercedes all previous drawings to which it refers. Drawn: rdh Date: Approved: sdb Date: 12/08/2011 Sheet Size: D Scale: 1 : as noted Sheet Description: 1 1 FURNITURE PLAN 1/8" = 1'-0" INTERIOR ELEVATION 1/8" = 1'-0" Furniture Plan Sheet Number: A7-1 (C) 2011 MW Bender Architecture, LCC