High-Capacity Optical Networks With or Without Repeaters
Transcription
High-Capacity Optical Networks With or Without Repeaters
High-Capacity Optical Networks With or Without Repeaters Massimo Leo Fiberoptikk Conference – Trondheim, Norway – 2-3 November 2015 © 2015 Xtera Communications, Inc. Proprietary & Confidential 1 The Data Center Opportunity in Norway • Cool climate and supply of cold water natural free cooling • Green power Europe’s largest producer of hydroelectric power • Surplus of renewable, tax-friendly energy lower costs Opportunity for High Capacity and Cost-per-Byte efficiency © 2015 Xtera Communications, Inc. Proprietary & Confidential 2 Interconnecting Data Centers DCI Market Trends Source: Ovum 2015 Cloud and video are driving data center builds ...and changing how networks are constructed DCI is the fastest growing application for optical networking …DCI revenues grew 16.2% in 2014, surpassing US$2.5bn, and projected to grow at 10.5% CAGR Most Content Providers are securing fiber and building their own networks …as opposed to lease managed capacity services from Carriers © 2015 Xtera Communications, Inc. Proprietary & Confidential 3 Optical Networking Requirements for DCI and International Connectivity • High Capacity – Maximize # of Tbps per Fiber • Long Spans & Reach – Minimize # of Intermediate Sites – Reach out Longer Distances • Low Latency – Minimize # of Regeneration Sites • Over Land & Under Sea – Converged Terrestrial and Submarine Optical Solutions – Cost-efficient also across Short Distances © 2015 Xtera Communications, Inc. Proprietary & Confidential 4 Driver for Longer Single-Span Optical Systems City A Optical Equipment Optical Equipment Optical Equipment Innovative Unrepeatered Offering PoP or DC Cable Landing Station Submarine cable Terrestrial extension City B Optical Equipment Confidential – Xtera Communications, Inc. Proprietary © 2015 Xtera Communications, Inc. Proprietary & Confidential 5 Direct PoP-to-PoP: Better Cost/Bit and Latency Removing CLS Equipment Optical Equipment City A PoP or DC Submarine cable Terrestrial extension BMH BMH City B Optical Equipment Requires Superior Optical Technology Innovative Unrepeatered Offering Confidential – Xtera Communications, Inc. Proprietary © 2015 Xtera Communications, Inc. Proprietary & Confidential 6 Maximizing Reach in Single-Span Systems Tool Kit (1/3) 1. Fiber – Lower attenuation fiber is always better Ultra low-loss (G.652B, G.654B) – Type Fibers with large effective area tolerant to higher launched power 2. Electro-Optics Silicon – – – – – – – Line rate 100G, 150G, 200G, 300G, 400G and Beyond Modulation format Pulse shaping Channel density and flex grid Wavelength of transmission (fiber attenuation lower in L-band) Detection (Coherent) Forward Error Correction (Soft-Decision FEC) 3. Power Management – Launched power; power in the line fiber – Non-linearities mitigation © 2015 Xtera Communications, Inc. Proprietary & Confidential 7 Maximizing Reach in Single Span Systems Tool Kit (2/3) 4. Raman amplification – Results from the interaction of an optical radiation (“pump”) with molecular vibrations of the glass – In any fiber types – The more pump power the more gain – Raman gain improves with lower fiber attenuation (larger Leff) Thus the NF and OSNR improvements due to Raman will be larger in lower attenuation fiber at the same Raman pump power. Raman gain (a.u.) • Maximum gain at a shift of ~ 100 nm in the 1550 nm window 6 Pump 5 4 ~ 100 nm 3 2 1 0 0 6 Resulting gain 12 18 24 30 36 42 48 Frequency shift (THz) © 2015 Xtera Communications, Inc. Proprietary & Confidential 8 Raman Amplification Power Profile along the Span (Backward Raman) Fiber attenuation Gain from backward Raman pumping 266 km (61.2 dB); G.652D 15x100G © 2015 Xtera Communications, Inc. Proprietary & Confidential 9 Raman Amplification Power Profile along the Span (BWD & FWD Raman) Gain from forward Raman pumping Fiber attenuation Gain from backward Raman pumping 288 km (65.5 dB); G.652D 15x100G © 2015 Xtera Communications, Inc. Proprietary & Confidential 10 Maximizing Reach in Single Span Systems Tool Kit (Cont’d) 5. Remote Optically Pumped Amplifier (ROPA) – Passive sub-system, made up of a few optical components (housed in an enclosure jointed to the cable) and pumped from one end of the span (typically, receive end) – Basically, performs the function of a mid-span EDFA Erbium doped Signal fibre in Signal out Optical pump (from the receive terminal) – More pump power allows ROPA to be located further away from the terminals ~ 100 km ROPA © 2015 Xtera Communications, Inc. Proprietary & Confidential 11 Example of ROPA Enclosure for Subsea Applications Courtesy of Nexans © 2015 Xtera Communications, Inc. Proprietary & Confidential 12 ROPA Power Profile along the Span Gain from forward Raman pumping Fiber attenuation Gain from ROPA 373 km (76.1 dB); G.652B Gain from backward Raman pumping 107 km ROPA 15x100G © 2015 Xtera Communications, Inc. Proprietary & Confidential 13 Per channel power (dBm) 410 km (68.2 dB), 150 x 100G Unrepeatered Transmission over G.654B Fiber 150 wavelengths Gain from backward Raman pumping Fiber attenuation Gain from forward Raman pumping Gain from ROPA Transmission distance (km) LRA (Discrete Raman amplifier) 289 km LRA 121 km ROPA <Pout> = -2.8 dBm/ch <OSNR> = 14.2 dB Power (dBm) Power (dBm) 0 -5 -10 5 0 0 -5 -10 -15 -15 -20 1535 1545 1555 1565 1575 Wavelength (nm) 1585 1595 -25 1525 -5 -10 -15 -20 -25 1525 5 Power (dBm) 5 -20 1535 1545 1555 1565 1575 Wavelength (nm) 1585 1595 © 2015 Xtera Communications, Inc. Proprietary & Confidential -25 1525 1535 1545 1555 1565 1575 Wavelength (nm) 1585 1595 14 557 km (90 dB), 1 x 100G Unrepeatered Transmission over G.654B Fiber Corning® Vascade® EX2000 (G.654B), Aeff=112 mm2 • Backward AND forward ROPAs – No use of extra fiber for pumping Per channel power (dBm) • 1 wavelength Gain from forward Raman pumping Fiber attenuation Gain from ROPA Gain from ROPA Gain from backward Raman pumping Transmission distance (km) 133 km 291 km 133 km EDFA ROPA Forward Raman pumping ROPA Direction of transmission © 2015 Xtera Communications, Inc. Proprietary & Confidential Backward Raman pumping 15 Most Recent Unrepeatered Results by Xtera © 2015 Xtera Communications, Inc. Proprietary & Confidential 16 Raman for Multi-Span Applications 100G across Ultra-Long Spans over 2,266km OPGW 43 km 13.9 dB 278 km 63.1 dB 237 km 53.8 dB 142 km 34.6 dB 138 km 33.1 dB ROADM ILA ROADM ILA ILA Manaus TIM Manaus Rod Lexuga Silves Terra Santa Oriximiná ROADM 43 km 13.9 dB 239 km 54.2 dB ILA ILA ILA Villa Camburão 110 km 27.2 dB 235 km 53.5 dB ROADM Jurupari ROADM 183 km 46.1 dB Macapá TIM ILA Macapá Sub 141 km 33.9 dB Gopa Tucuruí Core amplifier Backward span extension module ILA Laranjal do Jari 157 km 37.2 dB Pacaja ILA Xingu Forward span extension module © 2015 Xtera Communications, Inc. Proprietary & Confidential 91 km 23.8 dB 229 km 52.8 dB ILA Vitória do Xingu G.652 fiber span 17 Why Using Wideband Raman Amplification in Subsea Repeaters? Google (ECOC – Sept 2014): Spectrum efficiency (bit/s/Hz) is now close to the Shannon limit… Need to either: 1. Increase the # of fibers: too expensive 2. Increase the # of cores: too long term (10+ year) solution 3. Expand the spectrum width (without compromising the reach) Option #3 is the one developed and field-proven by Xtera © 2015 Xtera Communications, Inc. Proprietary & Confidential 18 Mastering Raman Amplification 3x Capacity 240 channels 150 channels 80 channels 2x Reach More Capacity in Long Haul applications for 100G, 400G and Beyond © 2015 Xtera Communications, Inc. Proprietary & Confidential 19 World-first Raman Repeater for Subsea Cable Systems • 50% more optical bandwidth and longer spans • Down to 8,000m, up to 12kV • Titanium alloy: as strong as steel, yet 45% lighter • Very compact for easy seabed burial through plough © 2015 Xtera Communications, Inc. Proprietary & Confidential 20 Xtera Product Portfolio Maximizing Capacity and Reach For Optical Networks Partners Ecosystem In-House Developed Nu-Wave Optima NMS Single DWDM & SLTE Vessel Repeater Cable ROPA Branching Unit Submerged Equipment © 2015 Xtera Communications, Inc. Proprietary & Confidential Turnkey Solutions 24 Unified Terrestrial and Submarine Networks Xtera Portfolio and Application Example Terrestrial fiber Subsea fiber Regional Repeatered DWDM optical systems Unrepeatered Repeater Transoceanic Repeatered Branching Unit © 2015 Xtera Communications, Inc. Proprietary & Confidential 25 Conclusion • Field-proven Raman optical unrepeatered transport technologies can offer today: – Up to 600+ km unrepeatered reach – Up to 15 Tbit/s capacity per fiber pair • Optical unrepeatered transport technologies can be applied to multi-span links: – Key to minimize the number of intermediate sites – Long-span capabilities required for OPGW cable in utilities power grids • Raman-based optical subsea repeaters are now in commercial service for wider spectrum and/or longer repeater spacing. © 2015 Xtera Communications, Inc. Proprietary & Confidential 26 Maximizing Network Capacity, Reach and Value Over land, under sea, worldwide © 2015 Xtera Communications, Inc. Proprietary & Confidential 27
Similar documents
Maximizing Reach and Capacity of 100G Optical Networks
unrepeatered spans due to high sensitivity on nonlinear effects
More information