LMA10 absolute magnetic encoder system
Data sheet LMA10D01_04 Issue 4, 5th July 2016 LMA10 absolute magnetic encoder system Track system LMA10 is an absolute magnetic linear encoder system which has been designed for motion control applications as a position and velocity control loop feedback element. The encoder system is highly reliable due to contactless absolute measuring principle, built-in safety algorithms and high quality materials/components used. The measuring standard is a magnetic scale which consists of a stainless steel substrate with an elasto-ferrite layer. The readhead incorporates Hall sensor arrays for PRBS track reading, an AMR sensor for incremental track reading, interpolation electronics and custom logic circuitry. The data from the Hall arrays and interpolator are processed in the logic circuitry using special algorithms to determine the absolute position. ●● True absolute system ●● Suitable for highly dynamic control loops ●● Small footprint ●● High accuracy ●● Resolutions up to 0.244 µm ●● Axis lengths of up to 16.3 m The electronic design provides extremely short response and recovery ●● Speeds up to 7 m/s at 0.977 µm resolution times, which consequently make it ideal for applications with highly ●● Integral status LED dynamic control loops. ●● BiSS-C unidirectional Diagnostic information is available communication protocol through a serial communication ●● Simple and fast installation channel and status LED. ●● Robust measuring principle If a failure is diagnosed, the encoder The elasto-ferrite layer is magnetised needs to be switched off and then with two tracks. The incremental switched on again in order to resume track is magnetised with 2 mm long functionality. (alternating south and north) poles and the absolute track is magnetised with a pseudo random binary sequence (PRBS) absolute code with 13 bit length. The elasto-ferrite layer is immune to chemicals commonly found in industry. A ●● Excellent dirt immunity to IP68 associate company Data sheet LMA10D01_04 LMA10 dimensions Dimensions and tolerance in mm. 52 42 16 M3 through H D 17 4 5 3 ±0.2 3 46 Surface print on scale* 10 3 Incremental track Absolute track 10 AS10A\WWYY.BB M3 deep 4 * Scale surface print does not represent the actual ordering code. For orientation purpose only. Magnetic scale thickness (D) Ride height (H) Standard option Option 01 With back-adhesion tape 1.5 ±0.15 1.7 ±0.15 0.1 – 0.6 With back-adhesion tape, with cover foil 1.6 ±0.15 1.8 ±0.15 0.1 – 0.5 No back-adhesion tape 1.3 ±0.15 1.5 ±0.15 0.1 – 0.6 No back-adhesion tape, with cover foil 1.4 ±0.15 1.6 ±0.15 0.1 – 0.5 No back-adhesion tape, sides prepared for TRS 1.3 ±0.15 1.5 ±0.15 0.1 – 0.4 No back-adhesion tape, sides prepared for TRS, with cover foil 1.4 ±0.15 1.6 ±0.15 0.1 – 0.3 NOTE: Orientation of the readhead relative to AS10 magnetic scale should be according to the drawing. For reference use the surface print on AS scale or a magnet viewer (see image below). Incremental track Absolute track Magnetic viewer LMA10 installation tolerances Pitch ±1° Roll ±0.5° Lateral offset ±0.5° Yaw ±0.2 mm Status LEDs LED Green 2 Communication Status Yes Valid position data Green flashing No Valid position data Orange Yes Valid position data, > 80 % of max. speed Orange flashing No Valid position data, > 80 % of max. speed Red Yes Invalid position data Red flashing No Invalid position data Storage and handling > 60 mm N S WARNING: The AS magnetic scale should not be exposed to magnetic field densities higher than 50 mT on its surface. Magnetic fields higher than 50 mT can damage the scale. Motor oil Brake fluid Alcohol HCl Heptane Benzene Toluene CCl4 Storage –20 °C to +70 °C Antifreeze Turpentine Sea water Kerosene Steam Operating 0 °C to +55 °C (cable under non-dynamic conditions: –20 °C to +55 °C) C2HCl3 Up to 100 % RH Shield connection Encoder Customer electronics Inner shield 5V Extension cable Clock lines Data lines Sense lines 0V Outer shield A associate company 3 Data sheet LMA10D01_04 LMA10 technical specifications System data Maximum length for AS scale 16.3 m Incremental pole length 2 mm System accuracy ±40 µm/m Short range accuracy < ±10 µm/10 mm (see diagram 5) Coefficient of thermal expansion (CTE) 11 ±1 µm/m/K Hysteresis < 2 µm at 0.1 mm ride height (see diagram 1) Repeatability Better than unit of resolution for movement in the same direction Available resolutions [µm] Maximum speed [m/s] Maximum speed during power on ~ 0.244 ~ 0.488 ~ 0.976 ~ 1.953 ~ 3.906 ~ 7.812 1.75 3.5 7 10 10 10 0.5 m/s Electrical data Power supply 5 V ±5 % (voltage on readhead) Consider voltage drop over cable (see diagram 3 and 4) Set-up time after switch-on < 250 ms Power consumption (without load) < 150 mA Voltage drop on the cable 55 mV/m; 35 mV/m (sense lines parallel to power supply) Mechanical data Mass Readhead (with 1 m cable, no connector) 41 g, magnetic scale 60 g/m Cable PUR high flexible cable, drag-chain compatible, double-shielded 7 × 0.05 mm2 (AWG 30); 1 × 0.14 mm2 (AWG 26) durability: 20 million cycles at 20 mm bend radius at whole temperature range Environmental data Temperature Operating Storage 4 0 °C to +55 °C –20 °C to +70 °C Vibrations (55 Hz to 2000 Hz) 300 m/s2 (IEC 60068-2-6) Shocks (11 ms) 300 m/s2 (IEC 60068-2-27) Humidity 100 % (condensation permitted) EMC Immunity IEC 61000-6-2 (particularly: ESD: IEC 61000-4-2; EM fields: IEC 61000-4-3; Burst: IEC 61000-4-4; Surge: IEC 61000-4-5; Conducted disturbances: IEC 61000-4-6; Power frequency magnetic fields: IEC 61000-4-8; Pulse magnetic fields: IEC 61000-4-9) EMC Emission IEC 61000-6-4 (for industrial, scientific and medical equipment: IEC 55011) Environmental sealing IP68 (according to IEC 60529) 6 Max. clock frequency [MHz] Hysteresis [µm] 4 3 2 1 0 0 0.1 0.2 0.3 0.4 0.5 0.6 4.5 3 1.5 0 0.7 Without line delay compensation With line delay compensation 0 20 Ride height [mm] Diagram 1: Hysteresis vs. ride height 11 Maximum power supply voltage Minimum power supply voltage 13 10 7 4 0 20 40 60 80 7.5 5.75 0 13 Ride height + te La 60 80 100 Diagram 4: Required power supply voltage on cable end vs. overall cable length with sense lines connected parallel to power supply lines se off ) L=0 L = –0.2 11 9 7 40 Cable length [m] Accuracy error [μm] Short range accuracy [μmpp/10 mm] 15 20 LO t( l ra 100 Minimum power supply voltage 9.25 4 100 Diagram 3: Required power supply voltage on cable end vs. overall cable length L = 0.2 80 Maximum power supply voltage Cable length [m] 17 60 Diagram 2: Maximum clock frequency vs. cable length Required power supply voltage on cable end [V] Required power supply voltage on cable end [V] 16 40 Cable length [m] 0.1 0.4 Short range accuracy 0.6 Ride height [mm] Diagram 5: Short range accuracy vs. ride height-lateral offset (LO) as a parameter - typical Measuring travel [mm] Diagram 6: Definition of short range accuracy A associate company 5 Data sheet LMA10D01_04 LMA10DC - BiSS-C uni-directional interface Signal level RS422 Maximum clock frequency 5 MHz Length of position data 26 bit Length of status data 2 bit Length of CRC 6 bit (inverted bit output - polynomial 0x43) Position data encoding Pure binary Latency (tlatency) 0.8 µs at 5 MHz (otherwise 4 MA clock periods) Recovery (trecovery) ≥ 5 μs LSB = (2000 μm)/213 ≈ 0.244 μm (regardless the selected resolution) Timing diagram Encoder latches position value MA SLO ACK START CDS MSB tlatency LSB Error Position data Warning CRC Status data CRC CRC data trecovery Status data Bit Type “H” (“L” for option 03) E Alarm Invalid position data OK Movement too fast, demagnetisation, sensing distance too high, orientation of readhead and scale W Warning Valid position data, close to overspeed OK >80 % of maximum speed Connections Pin 9 pin D type plug ”L”(“H” for option 03) Colour Case Signal Outer shield 1 Inner shield 2 Pink MA + 3 Blue MA – 4 Yellow +5 V sense 5 Brown +5 V supply 6 Grey SLO + 7 Red SLO – 8 Green 0 V sense 9 White 0 V supply Cable specifications Number of wires 4.2 mm ±0.2 mm Jacket material Extruded polyurethane (PUR) White wire 0.14 mm2, 26 AWG, 0.13 Ω/m Other wires 0.05 mm2, 30 AWG, 0.35 Ω/m Durability Bend radius Weight 6 8 Outer diameter 20 million cycles at 20 mm bend radius Dynamic 25 mm, static 10 mm (internal radius) 34 g/m nominal Possible reason for failure NOTE: If controller does not support voltage sense functionality, we recommend connecting sense lines parallel to power supply lines in order to decrease voltage drop over cable. In case sense lines are not used and/or connected, they should be isolated in order to prevent possible shorts between power supply lines. LMA10 readhead part numbering LMA10 DC 13B 10 A 00 Output type DC - BiSS-C communication protocol Special requirements 00 - No special requirements (standard) 01 - Without LED 03 - Status bits active low 0M - Cable length in meters 3M - Status bits active low, cable length in meters Resolution 13B - 2/213 mm (~ 0.244 µm) 12B - 2/212 mm (~ 0.488 µm) 11B - 2/211 mm (~ 0.977 µm) 10B - 2/210 mm (~ 1.953 µm) 09B - 2/29 mm (~ 3.906 µm) 08B - 2/28 mm (~ 7.812 µm) Connector option A - 9 pin D type plug F - Flying lead (no connector) Cable length 10 - 1.0 m (standard) AS10 magnetic scale part numbering AS 10 A 01000 A 00 Scale width 10 - 10 mm width Special requirements 00 - No special requirements (standard). Maximum scale length up to 4 m. 01 - Maximum scale length up to 16.3 m. See table on page 2 for reference on scale thickness. Options A - Back-adhesion tape (standard) B - Back-adhesion tape, with CF10 cover foil* C - Back-adhesion tape, ends prepared for end clamping G - No back-adhesion tape, sides prepared for insertion into track system ** H - No back-adhesion tape, sides prepared for insertion into track system with CF08 cover foil* I - No back-adhesion tape N - No back-adhesion tape, with CF10 cover foil* P - No back-adhesion tape, ends prepared for end clamping Precision class A - ±20 µm/m Scale length xxxxx - Where xxxxx equals scale length in mm. Maximum scale length up to 4 m (up to 16.3 m with special option 01). * Cover foil supplied separately. ** For details on TRS track system please refer to data sheet LM10D18 on www.rls.si/trs. Hole to hole distance 1 Scale length Ends prepared for end clamping 3 ±0.5 3.5 ±0.5 10 ±0.2 Positive direction Surface print on scale* AS10A/WWYY.BB End clamp End clamp 5 5 Measuring length 2 START FINISH 1 2 Hole to hole distance (for end clamp mounting) = Scale length + (6 mm ±1 mm) Measuring length = Scale length - 42 mm Cover foil part numbering * Scale surface print does not represent the actual ordering code. For orientation purpose only. CF 10 1000 Width of cover foil 08 - 8 mm width (for track system option only) 10 - 10 mm width Foil length xxxx - Where xxxx equals foil length in cm A associate company 7 Data sheet LMA10D01_04 Accessories part numbering Applicator tool for magnetic scale and cover foil End clamp kit (2 clamps + 2 screws) LMA10ASC00 LM10ECL00 USB encoder interface Magnet viewer E201-9S MM0001 For details on E201 interfaces please refer to data sheet E201 on www.rls.si/e201. 8 ® Head office RLS merilna tehnika d.o.o. Poslovna cona Žeje pri Komendi Pod vrbami 2 SI-1218 Komenda Slovenia T +386 1 5272100 F +386 1 5272129 E mail@rls.si www.rls.si Document issues Issue Date Page Corrections made 1 6. 5. 2013 - 2 22. 4. 2014 3, 5 12. 11. 2014 5 Line delay compensation chapter added 25. 1. 2016 1 Axis length corrected 2 Note, magnetic viewer picture, new option 01 in table magnetic scale thickness 3 New storage and handling and shield connection 4 Maximum length for AS scale, maximum speed, cable data corrected, new voltage drop on the cable 5 New diagram 2 and 4, color changes in graphs 6 New note and cable specifications, corrected connections 7 Part numbering: new special requirements (01, 0M, 3M), new resolutions (09B, 08B) AS scale part numbering: new precision class, new special requirements (01) 8 New magnet viewer 2 Ride height table amended 3 4 5. 7. 2016 2, 6 New document New graphs, new special requirement and new data in technical specifications added. Ride height table amended , length of position data amended RLS merilna tehnika d.o.o. has made considerable effort to ensure the content of this document is correct at the date of publication but makes no warranties or representations regarding the content. RLS merilna tehnika d.o.o. excludes liability, howsoever arising, for any inaccuracies in this document. © 2016 RLS d.o.o. A associate company
Similar documents
LM10 linear magnetic encoder system
Magnetic scale (1 m) 60 g, Cover foil (1 m) 3.5 g
More information