New micro pipette from Nichiryo
Transcription
New micro pipette from Nichiryo
Specifications Cat. No Tips/Racked tips (Autoclavable) Volume Settings Volume range (µl) Increments(µl) 0.1 - 2 0.002 00-NPP-2 00-NPP-10 00-NPP-20 0.5 - 10 0.01 2 - 20 0.02 00-NPP-100 Digital 10 - 100 0.1 00-NPP-200 Setting 20 - 200 0.2 00-NPP-1000 100 - 1000 1 00-NPP-5000 1000 - 5000 10 00-NPP-10ML 1000 - 10000 10 Volume (µl) Accuracy (%) Precision (%) 0.2 ±12.0 ≦6.0 1 ±5.0 ≦2.5 2 ±3.0 1 Cat. No Volume range (µl) 00-BMT-UT 00-BMT-UTR 00-BMT-SS 00-BMT-SSR Color Length of tips (mm) 0.1 - 10 31.4 0.5 - 10 45.7 Q’ty 1000 (bag) 960 (96pcs.×10c /s) 1000 (bag) NEW 960 (96pcs.×10c /s) 1000 (bag) 00-BMT-SG 2 - 200 Clear 53.0 960 (96pcs.×10c /s) 00-BMT-SGR 00-BMT-L 100 - 1000 77.0 1000 - 5000 132.0 1000 - 10000 158.0 00-BMT-LR 00-BMT-X 00-BMT-XR 00-BMT-Z 1000 (bag) 1000 (100pcs.×10c /s) 200 (bag) 100 (50pcs.×2c /s) 200 (bag) Accuracy and Precision Cat. No 00-NPP-2 00-NPP-10 00-NPP-20 00-NPP-100 Cat. No Volume (µl) Accuracy (%) 20 ±1.0 ≦0.5 100 ±0.8 ≦0.3 ≦1.0 200 ±0.8 ≦0.2 ±4.0 ≦3.0 100 ±1.0 ≦0.5 5 ±1.0 ≦1.0 500 ±0.8 ≦0.3 10 ±1.0 ≦0.5 1000 ±0.7 ≦0.2 2 ±5.0 ≦3.0 1000 ±1.0 ≦0.3 10 ±1.0 ≦1.0 2500 ±0.8 ≦0.3 20 ±1.0 ≦0.4 5000 ±0.6 ≦0.2 10 ±2.0 ≦1.0 1000 ±2.0 ≦0.4 50 ±1.0 ≦0.3 5000 ±0.8 ≦0.3 100 ±0.8 ≦0.3 10000 ±0.4 ≦0.2 00-NPP-200 00-NPP-1000 00-NPP-5000 00-NPP-10ML Precision (%) The AC and CV above are measured with the disposable tips described in the catalogue. The AC and CV at 0.2µl depend much on the sampling skill and the sampling condition where pipettes are used. Accessories [ Tube opener ] [ Stand ] Cat. No : 00-NTO Q’ty : 3 Cat. No : 00-MLT-STD2 Capacity : 6 Cat. No : 00-BM-STD Capacity : 6 Cat. No : 00-NLE-STD Capacity : 1 Parts and Disposables [ 2µl - 1000µl ] Description Plunger set [ 5000µl, 10ml ] Contents Plunger Plunger head O-ring Seal ring Nozzle cylinder Nozzle cylinder O-ring & Seal ring set O-ring Seal ring Ejector pipe Ejector setting screw set Filter 2µl - 1000µl Description Plunger set 2µl - 1000µl First spring Nozzle cylinder set Volume Setting screw Spring washer Washer 10pcs Nozzle filter remover Adjustment Tool Sizes of the parts depend on the volume range. Please check before ordering. 2µl - 20µl Nozzle cylinder set 100µl - 1000µl Nozzle cylinder O-ring 100µl - 1000µl O-ring & Seal ring set 2µl - 1000µl Ejector pipe Contents Plunger Joint block (with O-ring) Joint plate Joint shaft Nozzle cylinder O-ring 10ml 5000µl , 10ml 5000µl , 10ml 5000µl , 10ml 3pcs Ejector setting screw set 4pcs 1000µl Filter 100pcs 1000µl Nozzle filter remover 2µl - 10ml 5000µl 5000µl , 10ml O-ring Seal ring Ejector setting screw set 2µl - 1000µl Volume Adjustment Tool 5000µl 10ml 5000µl , 10ml 5000µl , 10ml 2µl - 10ml Debut Campaign Sizes of the parts depend on the volume range. Please check before ordering. 5-year warranty Distributor 2, Kandamikura-cho, Chiyoda-ku, Tokyo, 101-0038, Japan Te l : +81-3-6661-2602 Fax : +81-3-6661-2604 E-mail : i-sales@nichiryo.co.jp URL: www.nichiryo.co.jp 090803A Innovation in Durability, Strength, Stability, and Comfort New micro pipette from Nichiryo NICHIRYO’S accumulated technology through the years has reached the next level of innovation for an all new pipette. Nichiryo introduces the state of the art “Nichipet Premium”. Based on a long quest for the ideal pipette component, function and design Nichiryo now launches the professional model “Nichipet Premium”. MADE IN JAPAN Innovation in “Durability” and “Strength” – That’s “Premium” Nichipet premium carries new technology for materials used in the internal components and outer body. Nichipet Premium strengthens its durability and prolongs life in tough laboratory conditions. Improved abrasion tolerance “Long Life”. Debut Campaign Improved Durability “Tough Body”. Seal ring of the Premium is tested dispensing / aspirating 600,000 times. Non-greased plunger makes it easy to maintain. ( 2µl – 1000µl ) 5-year warranty New material used for 4 notches- lock improves its strength, which minimizes the lever shifting from the original position. The test was conducted by Nichiryo.The test result may vary with condition of usage. Tested 600,000 Nozzle top is highly abrasion tolerant. Materials used for pipette body have high tolerance to solvents and to drop impact. Hyper Blower System, longer second-push stroke, improves dispensing efficiency. ( 2µl, 10µl, 20µl ) Easy-Calibration function provides for simple in lab calibration. Single hand pipetting can be done smoothly to improve operation efficiency. Renewed internal construction improves accuracy and reproducibility. Hand temperature doesn’t permeate through the body of the pipette. Therefore the accuracy of the volume measurement is not affected. ( Patented ) Slim nozzle can be easily inserted into tubes to aspirate. All components are manufactured and assembled in Japan to ensure the quality and reliability of the pipette. How we can relieve fatigue and improve comfort from pipette operations . . . That is what we are looking for all the time. The premium provides high efficiency to relieve fatigue and stress from many repetitive operations. New round form of the Premium mitigates fatigue and stress from heavy workload. ( 2µl – 1000µl ) ceramic plunger Innovation in “Stability” and “Preciseness” – That’s “Premium”. While maintaining a number of positive aspects of the Nichipet EX, the Nichipet Premium upgrades internal functionality in order to sustain better accuracy and reproducibility. In addition, handling comfort supports fast and smooth liquid handling for researchers. Innovation in “Fatigue-Free” and “Comfort” – That’s “Premium”. times Seal ring UV Resistance Non corrosive ceramic used in the plunger ( 100µl – 10ml ) The 5-year warranty can be applied for all of Nichipet Premiums until purchase of June 30, 2010. The 5-year warranty can be valid for Nichipet Premiums registered by a 5-year warrantee registration form attached with items. The 5-year warranty does not cover defects caused by excessive wear and tear or damage due to shipping, accident, abuse, misuse, or usage not in accordance with instructions manual, or damage caused by liquid permeation in the nozzle corn. Enlarged push button is easy to depress. The body ditch prevents pipette from slipping. What’s new! Shortened to release tension to your thumb. Shortened the distance to operate smoothly Enlarged easy to read counter display for volume setting.