TJ GRAND - Tech Specs - Updated Apr, 2016
Transcription
TJ GRAND - Tech Specs - Updated Apr, 2016
1 Theatre junction GRAND Technical Specifications (Updated April, 2016) LOCATION: Theatre Junction GRAND, 608 1st Street SW, Calgary, AB, Canada T2P 1M6 CONTACT INFORMATION: Mailing Address: Theatre Junction GRAND 608 1st Street SW Calgary, AB Canada T2P 1M6 Website: theatrejunction.com Telephone: Main Line: Venue Rental Inquiries: Technical Information: Box Office: 403 205 2922 ext 210 ext 230 ext 1 Fax: Administration: Box Office: 403 263 3605 403 205 4515 THEATRE JUNCTION STAFF: Artistic Director: Executive Director: Technical Director: Mark Lawes, mark@theatrejunction.com Guy de Carteret, guy@theatrejunction.com Phil Cimolai, phil@theatrejunction.com Theatre Junction GRAND – Technical Specifications 4/12/2016 2 CREW CALLS: Theatre Junction proudly operates under a collective agreement with IATSE Local 212 and all work performed on stage or on company equipment will be done by on call, permitted, IATSE technicians within their corresponding departments. Crew calls are determined at the sole discretion of the venue’s Technical Director based on an assessment of the productions technical documents and needs. No third party technical staff will be allowed to work within the venue other than exclusively on the equipment that they provide. Road crews will be permitted to operate their show specific equipment only under the supervision of the venue’s house technicians. Artist’s sound and lighting technicians may operate the venue’s control consoles under the supervision of the venue’s house crew. The final say on all sound and lighting levels will be at the discretion of the venue’s house crew, no exceptions. In specific circumstances road crews may be permitted to perform additional tasks within the venue but only as pre approved by the venues Steward and Technical Director. In extreme cases, failure to comply with these regulations may result in the termination of the performance with no fault or liability to Theatre Junction. VENUE MEASUREMENTS: The theatre is a ‘black-box’ space capable of multiple stage configurations. There is no raised stage (the stage area is the venue floor), but if needed a large stage can be built out of portable risers. Standard Stage Width & Depth: Width: Depth (varies with seating configuration): 54’ (16.46m) 29’- 36’ (8.84m - 10.97m) Venue Width & Depth: Wall-to-Wall (stage floor level): Wall-to-fixed riser storage (seating collapsed): 54’ 69’ (16.46m) (21.03m) Venue Height: Stage Floor to Public Gallery Floor: Stage Floor to Technical Gallery Floor: Stage Floor to Underside of Grid (lowest point): Stage Floor to Walking Surface of Grid: Stage Floor to Underside of Structural Beams in Grid: 13’ 25’ 40’ 40.2’ 48’ (3.96m) (7.62m) (12.19m) (12.25m) (14.63m) STAGE/SEATING CONFIGURATIONS: Theatre Junction GRAND has eight different standard layouts offering configurations of audience on one, two, or three sides of the stage, or an open space – i.e. a flat floor with no seating. The audience seating system consists of a combination of permanently installed and mobile banks of retractable seating. Layout Type ‘Large Italian’ ‘Small Italian’ Maximum Audience Capacity 436 340 Theatre Junction GRAND – Technical Specifications Approximate Stage Dimensions (including wing space) 54’-0”W x 29’-0”D 54’-0”W x 29’-0”D 4/12/2016 3 ‘Open Space’ (no seats) 441 persons total (including performers) Please Note: • Storage of the unused banks of seats is either along the sidewalls of the venue or in the loading dock depending on the layout, as indicated on the technical drawings. • Setting and storing of the seating must be factored into the user’s set-up and strike time. • Audience egress and fire exits must not be obstructed at any time and a minimum 4’ clear path must be maintained. CROSSOVER: There is a permanent crossover under the stage via stairs between the NE and SE corners of the venue. The NW and SW corners of the venue may also be accessed under the stage via the lobby vestibule. Otherwise, stage level crossovers and other access requirements should be considered in the design of the scenery and masking layout. STAGE FLOOR: The stage floor is composed of black battleship linoleum over two layers of 1” plywood decking laid over 2” x 4” sleepers. No fixing to the floor will be allowed for any reason. There are no traps in the floor. There is a shallow cable trough that follows the perimeter of the room. PORTABLE RISERS: The venue has a stock of portable interlocking risers and step units. The surface of the risers consists of one-inch plywood covered with battleship linoleum. It is not allowed to screw into the risers. The maximum load is 100lb per square inch. Platforms: 40 4’(1.2m) x 8’(2.4m) 10 3’(0.9m) x 8’(2.4m) 2 3’(0.9m) x 4’(1.2m) Legs (4 per riser): 220 pcs for 1’(0.3m) H stage 220 pcs for 2’(0.6m) H stage 220 pcs for 3’(0.9m) H stage Step Units: 8 pcs for 1’(0.3m) H stage - 3’(0.9m) 2 pcs for 2’(0.6m) H stage - 3’(0.9m) W (w/ handrails) 2 pcs for 3’(0.9m) H stage- 3’(0.9m) W (w/ handrails) Skirting: Theatre Junction GRAND – Technical Specifications 4/12/2016 4 Misc. Velcro-backed velour panels at 1, 2 and 3’high (0.3, 0.6 and 0.9m) by 4, 8 and 16’(1.2, 2.4 and 4.8m) lengths. DANCE FLOOR: Please consult the Technical Director regarding possible configurations and availability of dance floor (Marley). The venue owns a ‘Harlequin Reversible’ brand dance floor in black/grey. The venue does not have a portable ‘sprung’ floor system. RIGGING: The rigging of lighting, sound and scenery/soft goods within the venue is achieved by trusses suspended from chain motors attached to the overhead fixed grid. Before any movement of the rigging over the stage may be incorporated into the performance, a formal documented risk assessment will have to be conducted and adequate safety measures implemented. The Technical Director shall have final determination in such matters. In no instance shall there be any moving rigging over the audience areas when occupied. The venue’s Technical Director will have the final decision regarding all rigging, no exceptions. TRUSS INVENTORY: 12”W 35 12 20 18 x 12”H (0.3m x 0.3m): pcs at 8’-0” (2.4m) L (w/ spigots) pcs at 10’-0” (3m) L (w/ spigots) corner sections ‘T’ sections 6” W x 12”H (0.15m x 0.3m): 90 pcs at 8’ (2.4m) lengths 02 pcs at 2’ (w/ spigots) - extension truss for Large Italian configuration MOTOR INVENTORY: The motors are located in the permanent grid and clamp to overhead structural beams. 39 24 CM lodestar – ½-ton chain hoists w/ 65’ chain, single-speed CM lodestar – 1-ton chain hoists, w/ 65’ chain, single-speed MOTOR CONTROL: 1 1 64-way analog controller custom touch screen remote controller (on deck) Theatre Junction GRAND – Technical Specifications 4/12/2016 5 SOFT GOODS / TRACKS: Black Legs (without fullness): 2 9' W x 34' L (2.4m x 10.3m) 10 9' W x 27' L (2.4m x 8.2m) 8 6’-7” W x 27’ L (1.8m x 8.2m) Black Borders (without fullness): 1 52' W x 18' L (15.8m x 5.4m) 3 48' W x 9' L (14.6m x 2.7m) Black Backings: (w/ 50% fullness) 2 26' W x 33'-6” L (7.9m x 9.7m) (used as a house curtain in Italian config.) 2 26' W x 27' L (7.9m x 8.2m) (used as a traveler) Traveler Tracks: 1 ADC 280 Series Track System - 52’-0” wide w/ 1’-0” overlap at centre 1 ADC 170 Series Track System - 48’-0” wide w/1’-0” overlap at centre Cyclorama: 1 PVC rear projection cyc 48’-0” wide by 30’ high (14.6m x 9.1m) Theatre Junction GRAND – Technical Specifications 4/12/2016 6 LIGHTING SYSTEM INFORMATION: Control System: Console / Data 1 ETC Gio 2K 240 control channels with electronic soft patch to dimmers 1 wireless remote control 1 designer monitor DMX in and out (XLR 5) throughout venue with patch-bay in booth 2 DMX octo-splitters in booth Ethernet (Ethercon) throughout venue with patch-bay in booth Dimmers / Circuits 2 ETC Sensor+ 48 module dimmer racks 192 2.4 Kw dimmers, dimmer per circuit. 32 socapex circuit boxes distributed throughout venue Each box has 1 socapex twofered with 6 – 20A twist lock connectors Cable 12 100’ socapex extension cables (12 AWG/14 conductor) 20 50’ socapex extension cables (12 AWG/14 conductor) 18 25’ socapex extension cables (12 AW/14 conductor) 28 socapex to female 20A twist lock ‘break-out’ adaptors 107 20A twist lock extension cables (12 AWG SJOOW) in 10’, 25’, 50’and 100’ lengths 50 20A twist lock twofers House Lights Manual controller with 50’ extension cord ETC Source Four Pars are permanently mounted in the grid to cover the entire venue but are zoned to allow isolation of a given stage layout (can be console controlled) Lighting Instrument Inventory: All with ‘New-style’ 20A twist lock connectors. Please confirm what instruments are available for your show. Fixed Profile Fixtures 6 19° 575w ETC Source 4 24 26° 575w ETC Source 4 24 36° 575w ETC Source 4 18 50° 575w ETC Source 4 TOTAL FIXED FOCUS ETC SOURCE 4’s = 72 Additional ETC Source 4 Barrels / Lenses 7 add’l 26˚barrels ETC Source 4 8 add’l 36˚barrels ETC Source 4 2 add’l 50˚barrels ETC Source 4 Zoom Profile Fixtures Theatre Junction GRAND – Technical Specifications 4/12/2016 7 6 6 15°-30° 25°-50° Fresnel Fixtures 12 6” PAR Fixtures 48 S4 Par 750w ETC Source 4 750w ETC Source 4 1Kw Strand Fresnelite (w/ barn doors) 575w ETC Source Four Par (w/ interchangeable lens set -VSNP, NSP, MFL, WFL) Cyc/Flood: 15 1-cell cyc light/ground row 1Kw 4 3-cell cyc lights L&E Broad Cyc 1Kw Strand Iris-3 Intelligent Inventory: 18 Chroma-Q Color Block DB4 1 Chroma-Q Color Block PSU30 4 Apollo Right Arm Each mounted with: 26° ETC Source Four – 750W (not counted above) Apollo Smartcolor PRO 7.25 colour scroller Apollo EZ Iris Smartcolor PRO 7.25 colour scrolls, in order: R00, R132, R3206, R302, R305, R99, R16, R321, R23, R24, R33, R336, R54, R57, R63, R65, R84, R388, R94, R26, R4390, R4790, R4290, R4590 Accessory / Hardware 58 ETC Source Four ‘A’ size gobo holder 4 Apollo glass gobo holder (only fits Apollo’B’ size glass gobos) 12 Strand Lekolite gobo holder 12 ETC Source Four drop-in Iris 12 6 ¼” gel extender (can be used as a top hat) 20 Floor plate 20 25lbs sandbags 10 50 lb boom base with 10x 5’ and 4x 10’ threaded vertical pipes 10 5’ Sched 40 Steel boom 6 10’ Sched 40 Steel Boom 18 Long Sidearm 22 Short Sidearm 24 Sliding T-Flange ROAD POWER: 1 1 1 1 100 A, 3 phase, 120/208V disconnect switch in alcove in the east wall 200 A, 3 phase, 120/208V disconnect switch in alcove in the southeast corner 400 A, 3 phase, 120/208V disconnect switch beside the loading dock door 200 A, 3 phase, 120/208V disconnect switches on the south wall at grid level Theatre Junction GRAND – Technical Specifications 4/12/2016 8 POWER TRANSFORMERS: 2 3 4 1500W Step Up Voltage Transformer to 220v – with universal socket 1000W Step Up Voltage Transformer to 220v – with universal socket 500W Step Up Voltage Transformer to 220v – with universal socket SPECIAL EFFECTS: Atmospherics: Please inform the Technical Director of any atmospherics (haze, fog, snow, dry ice, etc.) that you will be using. A copy of the ‘Material Safety Data Sheet for the fluids’ is mandatory. Use of atmospherics requires the disabling of the venue’s fire alarm system by the head stage carpenter, and approval by the venues Technical Director. Absolutely no atmospherics may be run under any circumstances until explicit clearance has been given. Failure to comply with this regulation may result in a damages charge. Pyrotechnics: Pyrotechnic special effects may be used with the approval of the Technical Director under the supervision of a licenced pyro-technician. The pyro-technician must show proof of proper licensing. Handling, storage and preparation of pyrotechnic material will be in compliance with the federal, provincial and local codes, and within the manufacturer’s guidelines. Where applicable, nearby flammables (costumes and scenery) will be properly flame proofed. A detailed application will be submitted to the Technical Director two months before the event. Upon approval, this application must then be submitted to the Calgary Fire Department. Documentation will include: event approval form; proof of $1 million liability insurance; copy of the pyrotechnician’s license; pyro effects plan; (with full description of all effects); sketch of the theatre (with position of effects, pyro storage, audience, exits). There will be at least one dry run (demonstration) of all effects prior to the first performance. Miscellaneous: The use of any other effects (strobes, firearms, gunshots etc.) requires the approval of the Technical Director. Theatre Junction GRAND – Technical Specifications 4/12/2016 9 SOUND SYSTEM INFORMATION: Theatre Junction GRAND (TJG) is equipped with a highly versatile and adaptable sound system designed to meet the needs of a wide array of configurations, clients, and artists. The backbone of this system is its patch architecture, which is broken out at many locations throughout the facility. This allows inputs and outputs to be routed fairly easily to and from the tech booth, stage floor, third floor pin rail, grid, studio, and lobby. The XLR patch architecture allows for 48 channels to the stage. Please note there is no splitter system in house. TJG also features a distributed audio AC system with an isolated ground. Audio AC are orange outlets throughout the facility in both twist lock 4 pin (60A) and standard North American U ground (15A) receptacles. The Digico SD9 (40 channel) is the main control console for our system and offers a wide array of EQ, Dynamics, and I/O routing options. Our second console (for use as a monitor or alternative desk) is a Yamaha DM2000 (48 channel). Our Meyer speaker system is comprised of 12 mid high cabinets (Meyer UPJ-1P), and 4 subwoofer cabinets (USW-1P). We also have 6 self-powered monitor/full range speakers available for use as monitors or main systems. Typically two are installed in our studio space as the main PA but could be recovered if a total of 6 monitors are required and the studio is not in use. The standard speaker configuration in the main theatre is made up of left (2 speakers), right (2 speakers) and centre (3 speakers) clusters, which reside on line set #1 as well as one mid high speaker per side flown on the pin rail as a delay fill for the back of the house. In addition to the flown clusters there are 2 flown subwoofers. We have 2 additional mid high cabinets and 2 additional subwoofers that can be added on the ground to provide extended front row coverage. Any request to relocate or modify this speaker configuration will result in extra labor costs. The system is typically addressed by a single stereo send distributed by our system processor however discrete addressing of up to 8 separate zones/clusters can be achieved simply if this is required (please give advanced notice). It is a major concern of both our management and patrons that acceptable sound levels be maintained. It is recommended that sound pressure levels should be no greater than 95dB A-weighted on average. Should you require additional information about our audio equipment or custom setups please contact Technical Director Phil Cimolai (phil@theatrejunction.com). Detailed Audio Equipment List: Speakers/Amplification: Self-powered bi-amp speakers Self-powered subwoofers Self-powered monitor/full range speakers Meyer Sound Meyer Sound UPJ-1P USW-1P 12 4 JBL PRX615M 6 Consoles/Processing: 40 channel digital console and Stage input rack Digico Theatre Junction GRAND – Technical Specifications SD9/32x8 Drack 4/12/2016 1 ea. 10 24 channel digital console 8 channel external preamp/AD System processor (8-in, 8-out) 12 channel analog mixer Stereo analog 15 band graphic eq Yamaha Yamaha BSS Soundweb Soundcraft Ashly Audio DM-2000 v2 AD8HR 3038 EFX12 MQX-2150 1 3 1 1 1 Playback: Audio show control software CD/cassette deck CD recorder Dual DJ CD player Stage Research Denon Denon Numark SFX PA/SC DN-T645 DN-C550R CDN 25+G 1 1 1 1 Intercom: Single channel belt-packs Wired headsets (dual muff) Wired headsets (single muff) Wall mount stations Wireless com (4-station) Wireless com dual channel beltpack Wireless headsets (dual muff) Clear-com Clear-com Clear-com Clear-com Radiocom Radiocom Radiocom RS-601 CC-260 CC-95 KB-211 BTR-800 TR 825 Telex 64437 5 2 3 2 1 4 4 Dynamic microphone Dynamic microphone Dynamic microphone Condenser microphone Condenser microphone Condenser microphone Condenser microphone (hanging) Condenser microphone (plate) Condenser microphone (plate) Direct input box Direct Input Box Direct Input Box Direct Input Box Dual wireless receiver Handheld microphone Beltpack Headset microphone Lavallier microphone Beige headset microphone Podium microphone Shure Shure Sennheiser Sennheiser Sennheiser Audio Technica Audio Technica Shure Crown Klark Teknik Radial Radial Radial Shure Shure Shure Shure Shure EV Shure SM-58 SM-57 MD-421 II MKH-50 MKH-40 4051A ES-933H Beta 91 PCC-160 DN100 Pro DI Pro D2 Pro AV UR4D UR2 UR1 Beta 53 WL-51 RE97S MX418 6 6 4 4 4 4 1 2 2 6 4 2 2 4 4 8 4 4 8 1 Tall boom mic stand Short boom mic stand Straight stand with round base KM KM KM 21090B 25900 26025 6 6 4 Self-powered studio monitors M-Audio BX5A 2 Microphones and Accessories: Theatre Junction GRAND – Technical Specifications 4/12/2016 11 VIDEO/COMPUTERS: Projectors: 8500 lumen 1080p Projector 3500 lumen 720p Projector Panasonic BenQ PTDZ870uk SP830 1 2 Screens: 22’x12’ 16:9 Front Projection Screen 9’x12’ 4:3 Front Projection Screen 5.5’x7.5’ 4:3 Front Projection Screen Da-Lite Draper N/A Da-Mat Fast Fold Pull Down 1 2 1 Cat5e Extenders: VGA Cat5e Extender HDMI Cat5e Extender Gefen Gefen VGA LR Gefen Toolbox 1 1 Computers: Macbook Pro (Early 2011) Mac Pro (Mid 2012) Apple Apple 8,2 5,1 1 1 LOADING DOCK: The loading dock is located in the alley to the south of 608 1st Street SW. It can accommodate up to 26’box 5-ton trucks. The Technical Director must be consulted regarding load-in procedures and truck positioning. City permits may be required. Dock Height: 3’-4” (1m) (Note: dock platform hinges down from in front of dock doors) Loading Door Dimensions: 9’-1” W x 9’-8”H (2.8m x 3m) (Note: doors at 90˚ to edge of dock) LIFTS & LADDERS: 1 1 1 1 1 1 Genie AWP-36AC personnel lift Genie AWP-25DC personnel lift 14’ A frame ladder 8’ stepladder 6’ stepladder 4’ stepladder max platform height of 36’ max platform height of 25’ FREIGHT ELEVATOR: Door Dimensions: Interior Dimensions: Load Capacity: Levels Accessed: Basement: Level 1: Level 2: 4’-1” W x 6’-8” H (1.25m x 2.1m) 10’-0”D x 6’-3”W x 7’-8” high (3.1m x 1.95m x 2.4m) 5000 pounds (2250 kg) dressing rooms, wardrobe, production office, green room, storage, restaurant kitchen stage, loading dock, lobby, box office, and restaurant upper lobby Theatre Junction GRAND – Technical Specifications 4/12/2016 12 Level 3: The Studio (rehearsal hall), technical booth, Theatre Junction admin. Offices DRESSING ROOMS/GREENROOM: There are three dressing rooms on the basement level that can accommodate a total of 22 people. Each room is equipped with hot and cold running water, showers, toilets, sinks, makeup mirrors and lights, chairs and wardrobe racks. There is also a green room in the basement with direct access to the stage. It contains a lounge area and a pantry with a refrigerator, dishwasher and microwave oven. WARDROBE: A wardrobe maintenance room is located in the basement and is equipped with basic equipment for maintenance including two domestic washers and dryers, an iron and ironing board, and steamer. Access to this area and equipment is restricted and prior arrangements must be made with the Technical Director for its use. Use of these facilities for personal laundry is not permitted. REHEARSAL HALL (THE STUDIO): The Studio is located on the 3rd level and is 29’ x 43’ (8.8m x 13m). It has a lighting grid at +18’-0” (5.4m) and is equipped with resilient floor (not directly on concrete) and basic lighting and sound systems. Note that use of The Studio is not included in the rental of the main theatre and it requires a separate booking. Haze, pyrotechnics or other atmospheric effects may not be used in the Studio under any circumstances. For further details on the studio’s technical specifications please contact the Technical Director. PRODUCTION OFFICE: There is one small production office for use by visiting management staff on the basement level in the dressing room corridor. It is equipped with a desk, chairs, and telephone. The telephone number is 403 205 2922 ext 216. MUSICAL INSTRUMENTS: There are no pianos or other musical instruments within the venue. Please consult the Technical Director to have them rented on your behalf. DRAWINGS: For detailed drawings of the venue including standard lighting plots, audio configuration, and masking layouts please contact the Technical Director. Drawings can be rendered in .vwx or .dwg Theatre Junction GRAND – Technical Specifications 4/12/2016