HAND-HELD DEVICES II
Transcription
HAND-HELD DEVICES II
Hand-Held Devices II Software Configuration Manual Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”). Owners of Datalogic products are hereby granted a nonexclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation. Should future revisions of this manual be published, you can acquire printed versions by contacting your Datalogic representative. Electronic versions may either be downloadable from the Datalogic website (www.scanning.datalogic.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other Datalogic publications, please let us know via the "Contact Datalogic" page. Disclaimer Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice. Datalogic is a registered trademark of Datalogic S.p.A. in many countries and the Datalogic logo is a trademark of Datalogic S.p.A. All other brand and product names referred to herein may be trademarks of their respective owners. CONTENTS 1 INTRODUCTION .......................................................................................... 1 2 INITIAL SETUP ............................................................................................ 3 3 CONFIGURATION...................................................................................... 12 USB PARAMETERS .................................................................................. 13 Handshaking ............................................................................................... 14 Ack/Nack Protocol....................................................................................... 14 Fifo.............................................................................................................. 15 Inter-character Delay .................................................................................. 15 Rx Timeout.................................................................................................. 16 Serial Trigger Lock...................................................................................... 16 Keyboard Nationality................................................................................... 17 Fifo.............................................................................................................. 18 Inter-character Delay .................................................................................. 18 Inter-code Delay.......................................................................................... 18 Control Character Emulation....................................................................... 19 RS232 PARAMETERS ............................................................................... 20 Baud Rate ................................................................................................... 21 Parity........................................................................................................... 22 Data Bits ..................................................................................................... 22 Stop Bits...................................................................................................... 23 Handshaking ............................................................................................... 23 Ack/Nack Protocol....................................................................................... 24 Fifo.............................................................................................................. 24 Inter-character Delay .................................................................................. 25 Rx Timeout.................................................................................................. 25 Serial Trigger Lock...................................................................................... 26 WEDGE PARAMETERS ............................................................................ 27 Keyboard Nationality................................................................................... 28 Caps Lock ................................................................................................... 29 Caps Lock Auto-Recognition (IBM AT compatible only) .............................. 29 Num Lock.................................................................................................... 30 Inter-character Delay .................................................................................. 30 Inter-code Delay.......................................................................................... 31 Control Character Emulation....................................................................... 31 Keyboard Setting ........................................................................................ 32 PEN EMULATION ...................................................................................... 34 Operating Mode .......................................................................................... 35 iii Minimum Output Pulse................................................................................ 36 Conversion to Code 39 ............................................................................... 37 Overflow...................................................................................................... 37 Output Level................................................................................................ 38 Idle Level..................................................................................................... 38 Inter-Block Delay......................................................................................... 39 IBM 46xx .................................................................................................... 40 IBM Data Formatting................................................................................... 41 DATA FORMAT.......................................................................................... 42 Code Identifier............................................................................................. 45 Custom Code Identifier ............................................................................... 46 Header ........................................................................................................ 47 Terminator................................................................................................... 48 Field Adjustment ......................................................................................... 49 Field Adjustment Character......................................................................... 50 Code Length Tx .......................................................................................... 50 Character Replacement .............................................................................. 51 POWER SAVE............................................................................................ 53 Scan Rate ................................................................................................... 54 Sleep State/USB Suspend .......................................................................... 54 Enter Sleep Timeout ................................................................................... 55 Standby....................................................................................................... 55 READING PARAMETERS ......................................................................... 56 Hand-Held Operation .................................................................................. 57 Stand Operation.......................................................................................... 57 Hardware Trigger Signal ............................................................................. 58 Trigger-off Timeout ..................................................................................... 58 Flash Mode ................................................................................................. 59 Reads per Cycle ......................................................................................... 59 Safety Time................................................................................................. 60 Beeper Intensity .......................................................................................... 60 Beeper Tone ............................................................................................... 61 Beeper Type ............................................................................................... 61 Beeper Length ............................................................................................ 61 Good Read Spot Duration........................................................................... 62 Stand Recognition Beep ............................................................................. 62 Automatic Operation Aiming Light............................................................... 63 Aiming System ............................................................................................ 63 DECODING PARAMETERS....................................................................... 64 Ink Spread................................................................................................... 65 Overflow Control ......................................................................................... 65 Interdigit Control.......................................................................................... 66 iv Decoding Safety.......................................................................................... 66 Puzzle Solver™ .......................................................................................... 67 CODE SELECTION .................................................................................... 68 EAN/UPC Family ........................................................................................ 70 2/5 Family ................................................................................................... 74 Code 39 Family........................................................................................... 75 Code 128 Family......................................................................................... 77 Code 93 ...................................................................................................... 78 Codabar Family........................................................................................... 79 MSI ............................................................................................................. 81 Plessey ....................................................................................................... 82 Telepen ....................................................................................................... 83 Delta IBM .................................................................................................... 84 Code 11 ...................................................................................................... 85 Code 16K .................................................................................................... 86 Code 49 ...................................................................................................... 86 RSS Codes ................................................................................................. 87 ADVANCED FORMATTING....................................................................... 88 Concatenation............................................................................................. 89 Advanced Formatting.................................................................................. 92 4 REFERENCES ......................................................................................... 107 A HOST CONFIGURATION STRINGS .......................................... 123 B CODE IDENTIFIER TABLE......................................................... 135 C HEX/NUMERIC TABLE............................................................... 135 v CONFIGURATION METHODS Reading Configuration Barcodes If you wish to change the default settings, this manual provides complete configuration of your reader in an easy way: To configure your reader: 1) Open the folded page in Appendix C with the hex-numeric table and keep it open during the device configuration. 2) Read the Enter Configuration code ONCE, available at the top of each page of configuration. 3) Modify the desired parameters in one or more sections following the procedures given for each group. 4) Read the Exit and Save Configuration code ONCE, available at the top of each page of configuration. Reference notes describing the operation of the more complex parameters are given in chapter 4. Using DL Sm@rtSet DL Sm@rtSet is a Windows-based utility program providing a quick and user-friendly configuration method via the RS232 or USB-COM interfaces. It also allows upgrading the software of the connected device (see the DL Sm@rtSet User’s Manual for more details). Copy Command A previously configured reader (Master device), can be used to send its configuration directly to other readers of the same type. The particular procedure for each device is given in par. 4.9. Sending Configuration Strings from Host An alternative configuration method is provided in Appendix A using the RS232 or USB interfaces. This method is particularly useful when many devices need to be configured with the same settings. Batch files containing the desired parameter settings can be prepared to configure devices quickly and easily. vi INTRODUCTION 1 INTRODUCTION This manual provides all the necessary information for complete software configuration of various Datalogic families of second generation Hand-Held Devices (HHD II), including CCD guns and readers and laser scanners. Your reader contains a built-in decoder and multi-standard interface. It is designed for use in a wide variety of applications and environments including commercial, office automation, retail, and light industrial applications where large quantities of information need to be collected rapidly, easily and reliably. It has several status indicator functions which are described in the next paragraph. 1 HHD II 1.1 STATUS INDICATORS Several status indicators are available depending on the type of reader: LEDs, Beeper, and Good Read Spot (for CCD Long Range readers only). They signal several operating conditions which are described in the tables below. H = high tone L = low tone READER START-UP Beeper 1 Meaning LLLL Parameters loaded correctly H H H H long tones HLHL Parameter loading error, reading or writing error in the non volatile memory Hardware error in EEPROM OFF No beeper performed when illuminator line is kept high at power on. READER CONFIGURATION Beeper 1 Meaning HHHH correct entry in Configuration mode L good read of a command LLL command read error LHHHH exit from Configuration mode READER DATA ENTRY Beeper 1 LED 2 one beep Good Read Spot Meaning ON ON correct read of a code in normal mode OFF OFF ready to read a code 1 only the Beeper Intensity command can modify these signals. 2 the data entry good read tone is user-configurable with all the Beeper commands in the Reading Parameters section. 2 INITIAL SETUP 2 INITIAL SETUP 2.1 INTERFACE SELECTION Follow the procedure to configure the interface required by your application USB Interface RS232 Interface Wedge Interface Pen Emulation Interface IBM 46xx Interface 2.1.1 USB Interface Configuration The USB interface is compatible with: - Windows 98 (and later) Mac OS 8.0 (and later) IBM POS for Windows 4690 Operating System The USB interface is compatible with: Windows 98 (and later) Mac OS 8.0 (and later) IBM POS for Windows 4690 Operating System START-UP As with all USB devices, upon connection, the Host performs several checks by communicating with the USB device. During this phase the LED on the device blinks and normal operations are suspended. Two basic conditions must be met before the USB device is ready to read codes, the correct USB driver must be loaded and sufficient power must be supplied to the reader. For all systems, the correct USB driver for the default USB-KBD interface is included in the Host Operating System and will either be loaded automatically or will be suggested by the O.S. and should therefore be selected from the dialog box (the first time only). If the Host supplies sufficient power to the reader, the start-up phase ends correctly, the LED stops blinking and the reader emits the beep OK signal. 3 HHD II If the Host does not supply sufficient power to the reader, a dialog box will appear on the Host and the reader will be blocked (LED continues blinking). In this case, disconnect the USB device cable at the Host (LED stops blinking), connect and power-up an external supply to the USB device cable then reconnect the USB device cable to the Host and close the dialog box. The reader emits the beep OK signal. You can now read codes. At this point you can read the USB interface configuration code according to your application. Load drivers from the O.S. (if requested). When configuring the USB-COM interface, the relevant files and drivers must be installed from the USB Device Installation software which can be downloaded from the web site: http://www.scanning.datalogic.com. The reader is ready. First Start-Up Connect device to Host with USB cable LED blinks Load drivers (if requested) LED off Disconnect reader at Host Connect external power supply to cable and power up BEEP OK Reconnect reader cable to Host and close dialog box YES Does a dialog box appear asking whether Bus power is sufficient? NO LED off - BEEP OK Select desired USB interface code Load drivers (if requested) Read test codes. Reader is READY 4 INITIAL SETUP Successive start-ups will automatically recognize the previously loaded drivers. If external power is used, verify that external power is already supplied. Successive Start-Ups Connect device to Host with USB cable Disconnect reader at Host Connect external power supply to cable and power up YES LED blinks Does a dialog box appear asking whether Bus power is sufficient? NO LED off - BEEP OK BEEP OK Reconnect reader cable to Host and close dialog box Read test codes. Reader is READY 5 HHD II USB INTERFACE USB-KBD Ì$+UA03$-:Î USB-KBD-ALT-MODE Ì$+UA04$-@Î USB-KBD-APPLE Ì$+UA05$-FÎ USB-COM* Ì$+UA02$-4Î USB-IBM-Table Top Ì$+UA00$-(Î USB-IBM-Hand Held Ì$+UA01$-.Î * 6 When configuring USB-COM, the relevant files and drivers must be installed from the USB Device Installation software which can be downloaded from the web site: (see http://www.scanning.datalogic.com). INITIAL SETUP 2.1.2 RS232 Interface Selection Read the restore default code, then read the interface selection code for your application: RESTORE DEFAULT Ì$+$*oÎ RS232 INTERFACE Standard Ì$+CP0$-$Î POS SYSTEMS Nixdorf Mode A Ì$+CM2EC0$->Î Fujitsu Ì$+CM1$-ÈÎ ICL Mode Ì$+CM0$-ÃÎ For POS system default settings refer to par. 4.10. 7 HHD II 2.1.3 Wedge Interface Selection Read the restore default code, then read the interface selection code for your application: RESTORE DEFAULT Ì$+$*oÎ WEDGE INTERFACE IBM AT or PS/2 PCs Ì$+CP500$-aÎ IBM XT Ì$+CP503$-vÎ PC Notebook Ì$+CP505$-ÈÎ IBM SURE1 Ì$+CP506$-$Î IBM Terminal 3153 Ì$+CP504$-}Î 8 INITIAL SETUP WEDGE INTERFACE (CONTINUED) IBM Terminals 31xx, 32xx, 34xx, 37xx: To select the interface for these IBM Terminals, read the correct KEY TRANSMISSION code. select the KEYBOARD TYPE if necessary (default = advanced keyboard). KEY TRANSMISSION MODE make-only keyboard Ì$+CP502$-oÎ make-break keyboard Ì$+CP501$-hÎ KEYBOARD TYPE advanced keyboard Ì$+FK1$-ÉÎ typewriter keyboard Ì$+FK0$-ÄÎ ALT MODE The following interface selection allows barcodes sent to the PC to be interpreted correctly independently from the Keyboard Nationality used. You do not need to make a Keyboard Nationality selection. (default = Num Lock Unchanged). Make sure the Num Lock key on your keyboard is ON. IBM AT - ALT mode Ì$+CP507$-+Î PC Notebook - ALT mode Ì$+CP508$-2Î 9 HHD II WEDGE INTERFACE (CONTINUED) WYSE TERMINALS ANSI Keyboard Ì$+CP509$-9Î PC Keyboard Ì$+CP510$-gÎ ASCII Keyboard Ì$+CP511$-nÎ VT220 style Keyboard Ì$+CP514$-ÇÎ DIGITAL TERMINALS VT2xx/VT3xx/VT4xx Ì$+CP512$-uÎ APPLE APPLE ADB Bus Ì$+CP513$-|Î 10 INITIAL SETUP 2.1.4 Pen Emulation Interface Selection Read the restore default code, then read the Pen Emulation interface selection code. RESTORE DEFAULT Ì$+$*oÎ PEN EMULATION Ì$+CP6$-BÎ 2.1.5 IBM 46xx Interface Selection (IBM Devices only) PORT 9B 4501 Protocol Ì$+CP800$-pÎ (typical) 1520 Protocol Ì$+CP801$-wÎ PORT 5B 1520 Protocol Ì$+CP801$-wÎ (typical) 4501 Protocol Ì$+CP800$-pÎ 11 HHD II 3 CONFIGURATION Once your reader is setup, you can change the default parameters to meet your application needs. Refer to chapter 2 for initial configuration in order to set the default values and select the interface for your application. In this manual, the configuration parameters are divided into logical groups making it easy to find the desired function based on its reference group. The first four groups are for Standard Interface parameter configuration, the fifth is only for IBM 46xx models: USB RS232 WEDGE PEN EMULATION IBM 46xx The following parameter groups are common to all interface applications: DATA FORMAT parameters regard the messages sent to the Host system for all interfaces except Pen Emulation. POWER SAVE manages overall current consumption in the reading device. READING PARAMETERS control various operating modes and indicator status functioning. DECODING PARAMETERS maintain correct barcode decoding in certain special reading conditions. CODE SELECTION parameters allow configuration of a personalized mix of codes, code families and their options. ADVANCED FORMATTING PARAMETERS allow code concatenation and advanced formatting of messages towards the Host. It cannot be used with Pen Emulation. 12 USB PARAMETERS USB-COM Handshaking, Ack/Nack protocol, FIFO, Inter-character delay, Rx timeout, Serial trigger lock USB-KBD Keyboard nationality, FIFO, Inter-character delay, Inter-code delay, Control character emulation USB-IBM No parameter selection required. 1. Read the Enter Configuration code ONCE, available at the top of each page. 2. Read configuration codes from the desired groups. 3. = Read the code and follow the procedure given = Default value Read the Exit and Save Configuration code ONCE, available at the top of each page. 13 Enter Configuration Ì$+;Î Exit and Save Configuration USB-COM HANDSHAKING disable ÌCE0WÎ hardware (RTS/CTS) ÌCE1ZÎ software (XON/XOFF) ÌCE2]Î RTS always ON ÌCE3`Î See par. 4.1.1 for details. ACK/NACK PROTOCOL disable ÌER0sÎ enable ÌER1vÎ See par. 4.1.2 for details. 14 Ì$-?Î Enter Configuration Ì$+;Î Exit and Save Configuration USB-COM Ì$-?Î FIFO disable ÌEC0UÎ enable ÌEC1XÎ See par. 4.1.3 for details. INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 milliseconds delay disabled 15 Enter Configuration Ì$+;Î Exit and Save Configuration USB-COM Ì$-?Î RX TIMEOUT timeout control in reception from Host ÌCL5Î Read 2 numbers from the table where: 00 = TIMEOUT disabled 01-99 = TIMEOUT from .1 to 9.9 seconds rx timeout 5 seconds See par. 4.1.4 for details. SERIAL TRIGGER LOCK disabled ÌCR0qÎ enable and select characters ÌCR1tÎ Read 2 characters from the Hex/Numeric table in the range 00-FE where: 16 First Character enables device trigger Second Character inhibits device trigger until the first character is received again. Enter Configuration Ì$+;Î Exit and Save Configuration USB-KBD Ì$-?Î KEYBOARD NATIONALITY Not Available for USB-KBD-ALT-MODE Interface This parameter default value is restored through the Interface Selection code and not Restore Default. Belgian ÌFJ7yÎ English ÌFJ4pÎ French ÌFJ2jÎ German ÌFJ3mÎ Italian ÌFJ1gÎ Japanese ÌFJ8|Î Spanish ÌFJ6vÎ Swedish ÌFJ5sÎ USA ÌFJ0dÎ 17 Enter Configuration Ì$+;Î Exit and Save Configuration USB-KBD FIFO disable ÌEC0UÎ enable ÌEC1XÎ See par. 4.1.3 for details. INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 milliseconds delay disabled INTER-CODE DELAY delay between codes transmitted to Host ÌFG.Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 seconds delay disabled 18 Ì$-?Î Enter Configuration Ì$+;Î Exit and Save Configuration USB-KBD Ì$-?Î CONTROL CHARACTER EMULATION CTRL+ Shift + Key ÌFO0nÎ CTRL + Key ÌFO1qÎ 19 RS232 PARAMETERS BAUD RATE PARITY DATA BITS STOP BITS HANDSHAKING ACK/NACK PROTOCOL FIFO INTER-CHARACTER DELAY RX TIMEOUT SERIAL TRIGGER LOCK 1. Read the Enter Configuration code ONCE, available at the top of each page. 2. Read configuration codes from the desired groups. 3. 20 = Read the code and follow the procedure given = Default value Read the Exit and Save Configuration code ONCE, available at the top of each page. Enter Configuration Ì$+;Î Exit and Save Configuration RS232 Ì$-?Î BAUD RATE 300 baud ÌCD1XÎ 600 baud ÌCD2[Î 1200 baud ÌCD3^Î 2400 baud ÌCD4aÎ 4800 baud ÌCD5dÎ 9600 baud ÌCD6gÎ 19200 baud ÌCD7jÎ 38400 baud ÌCD8mÎ 21 Enter Configuration Ì$+;Î Exit and Save Configuration RS232 PARITY none ÌCC0SÎ even parity ÌCC1VÎ odd parity ÌCC2YÎ DATA BITS 7 bits ÌCA0OÎ 8 bits ÌCA1RÎ 9 bits ÌCA2UÎ 22 Ì$-?Î Enter Configuration Ì$+;Î Exit and Save Configuration RS232 Ì$-?Î STOP BITS 1 stop bit ÌCB0QÎ 2 stop bits ÌCB1TÎ HANDSHAKING disable ÌCE0WÎ hardware (RTS/CTS) ÌCE1ZÎ software (XON/XOFF) ÌCE2]Î RTS always ON ÌCE3`Î See par. 4.1.1 for details. 23 Enter Configuration Ì$+;Î Exit and Save Configuration RS232 ACK/NACK PROTOCOL disable ÌER0sÎ enable ÌER1vÎ See par. 4.1.2 for details. FIFO disable ÌEC0UÎ enable ÌEC1XÎ See par. 4.1.3 for details. 24 Ì$-?Î Enter Configuration Ì$+;Î Exit and Save Configuration RS232 Ì$-?Î INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 milliseconds delay disabled RX TIMEOUT timeout control in reception from Host ÌCL5Î Read 2 numbers from the table where: 00 = TIMEOUT disabled 01-99 = TIMEOUT from .1 to 9.9 seconds rx timeout 5 seconds See par. 4.1.4 for details. 25 Enter Configuration Ì$+;Î Exit and Save Configuration RS232 Ì$-?Î SERIAL TRIGGER LOCK disabled ÌCR0qÎ enable and select characters ÌCR1tÎ Read 2 characters from the Hex/Numeric table in the range 00-FE where: 26 First Character enables device trigger Second Character inhibits device trigger until the first character is received again. WEDGE PARAMETERS KEYBOARD NATIONALITY CAPS LOCK CAPS LOCK AUTO-RECOGNITION NUM LOCK INTER-CHARACTER DELAY INTER-CODE DELAY CONTROL CHARACTER EMULATION KEYBOARD SETTING 1. Read the Enter Configuration code ONCE, available at the top of each page. 2. Read configuration codes from the desired groups. 3. = Read the code and follow the procedure given = Default value Read the Exit and Save Configuration code ONCE, available at the top of each page. . 27 Enter Configuration Ì$+;Î Exit and Save Configuration WEDGE Ì$-?Î KEYBOARD NATIONALITY This parameter default value is restored through the Interface Selection code and not Restore Default. Belgian ÌFJ7yÎ English ÌFJ4pÎ French ÌFJ2jÎ German ÌFJ3mÎ Italian ÌFJ1gÎ Spanish ÌFJ6vÎ Swedish ÌFJ5sÎ USA ÌFJ0dÎ The Japanese Keyboard Nationality selection is valid only for IBM AT compatible PCs. Japanese ÌFJ8|Î 28 Enter Configuration Ì$+;Î Exit and Save Configuration WEDGE Ì$-?Î CAPS LOCK caps lock OFF ÌFE0ZÎ caps lock ON ÌFE1]Î Select the appropriate code to match your keyboard caps lock status. Note: Caps lock manual configuration is ignored when Caps Lock Auto-Recognition is enabled. For PC Notebook interface selections, the caps lock status is automatically recognized, therefore this command is not necessary. CAPS LOCK AUTO-RECOGNITION (IBM AT COMPATIBLE ONLY) disable ÌFP0pÎ enable ÌFP1sÎ 29 Enter Configuration Ì$+;Î Exit and Save Configuration WEDGE Ì$-?Î NUM LOCK toggle num lock ÌFL1kÎ num lock unchanged ÌFL0hÎ This selection is used together with the Alt Mode interface selection for AT or Notebook PCs. It changes the way the Alt Mode procedure is executed, therefore it should be set as follows: if your keyboard Num Lock is normally on use num lock unchanged if your keyboard Num Lock is normally off use toggle num lock In this way the device will execute the Alt Mode procedure correctly for your application. INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 milliseconds delay disabled 30 Enter Configuration Ì$+;Î Exit and Save Configuration WEDGE Ì$-?Î INTER-CODE DELAY delay between codes transmitted to Host ÌFG.Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 seconds delay disabled CONTROL CHARACTER EMULATION CTRL+ Shift + Key ÌFO0nÎ CTRL + Key ÌFO1qÎ 31 Enter Configuration Exit and Save Configuration Ì$+;Î WEDGE Ì$-?Î KEYBOARD SETTING ALPHANUMERIC KEYBOARD SETTING The reader can be used with terminals or PCs with various keyboard types and nationalities through a simple keyboard setting procedure. The type of computer or terminal must be selected before activating the keyboard setting command. Keyboard setting consists of communicating to the reader how to send data corresponding to the keyboard used in the application. The keys must be set in a specific order. Press and release a key to set it. Some characters may require more than one key pressed simultaneously during normal use (refer to the manual of your PC or terminal for keyboard use). The exact sequence must be indicated to the reader in this case pressing and releasing the different keys. Example: If one has to press the "Shift" and "4" keys simultaneously on the keyboard to transmit the character "$" to the video, to set the "$", press and release "Shift" then press and release "4". Each pressed and released key must generate an acoustic signal on the reader, otherwise repress the key. Never press more than one key at the same time, even if this corresponds to the normal use of your keyboard. Press "Backspace" to correct a wrong key entry. In this case the reader emits 2 beeps. Note: "CAPS LOCK" and "NUM LOCK" must be off before starting the keyboard setting procedure. "SHIFT" must be repressed for each character and cannot be substituted by "CAPS LOCK". setting the alphanumeric keyboard ÌFB0TÎ Read the code above. Press the keys shown in the following table according to their numerical order: 32 Enter Configuration Exit and Save Configuration Ì$+;Î WEDGE Ì$-?Î Some ASCII characters may be missing as this depends on the type of keyboard: these are generally particular characters relative to the various national symbologies. In this case: The first 4 characters (Shift, Alt, Ctrl, and Backspace) can only be substituted with keys not used, or substituted with each other. characters can be substituted with other single symbols (e.g. "SPACE") even if not included in the barcode set used. characters can be substituted with others corresponding to your keyboard. The reader signals the end of the procedure with 2 beeps indicating the keys have been registered. 01 : Shift 02 : Alt 03 : Ctrl 04 : Backspace 05 : SPACE 06 : ! 07 : " 08 : # 09 : $ 10 : % 11 : & 12 : ' 13 : ( 14 : ) 15 : * 16 : + 17 : , 18 : 19 : . 20 : / 21 : 0 22 : 1 23 : 2 24 : 3 25 : 4 26 : 5 27 : 6 28 : 7 29 : 8 30 : 9 31 : : 32 : ; 33 : < 34 : = 35 : > 36 : ? 37 : @ 38 : A 39 : B 40 : C 41 : D 42 : E 43 : F 44 : G 45 : H 46 : I 47 : J 48 : K 49 : L 50 : M 51 : N 52 : O 53 : P 54 : Q 55 : R 56 : S 57 : T 58 : U 59 : V 60 : W 61 : X 62 : Y 63 : Z 64 : [ 65 : \ 66 : ] 67 : ^ 68 : _ (underscore) 69 : ` 70 : { 71 : | 72 : } 73 : ~ 74 : DEL 33 PEN EMULATION OPERATING MODE MINIMUM OUTPUT PULSE CONVERSION TO CODE 39 OVERFLOW OUTPUT LEVEL IDLE LEVEL INTER-BLOCK DELAY 1. Read the Enter Configuration code ONCE, available at the top of each page. 2. Read configuration codes from the desired groups. 3. 34 = Default value Read the Exit and Save Configuration code ONCE, available at the top of each page. PEN EMULATION The operating mode parameters are complete commands and do not require reading the Enter and Exit configuration codes. OPERATING MODE interpret mode Ì$]8Î Interprets commands without sending them to the decoder. transparent mode Ì$[4Î Sends commands to the decoder without interpreting them. 35 Enter Configuration Ì$+;Î Exit and Save Configuration PEN EMULATION Ì$-?Î MINIMUM OUTPUT PULSE high resolution code emulation 200 s ÌDG0\Î 400 s ÌDG1_Î 600 s ÌDG2bÎ 800 s ÌDG3eÎ 1 ms ÌDG4hÎ 1.2 ms low resolution code emulation See par. 4.2.1 for details. 36 ÌDG5kÎ Enter Configuration Ì$+;Î Exit and Save Configuration PEN EMULATION Ì$-?Î CONVERSION TO CODE 39 ► disable conversion to Code 39 ÌDA0PÎ Transmits codes in their original format. enable conversion to Code 39 ÌDA1SÎ Converts codes read into Code 39 format. See par. 4.2.2 for details. OVERFLOW narrow ÌDH0^Î medium ÌDH1aÎ wide ÌDH2dÎ See par. 4.2.3 for details. 37 Enter Configuration Ì$+;Î Exit and Save Configuration PEN EMULATION OUTPUT LEVEL normal (white = logic level 0) ÌDD0VÎ inverted (white = logic level 1) ÌDD1YÎ See par. 4.2.4 for details. IDLE LEVEL normal (black level) ÌDE0XÎ inverted (white level) ÌDE1[Î See par. 4.2.4 for details. 38 Ì$-?Î Enter Configuration Ì$+;Î Exit and Save Configuration PEN EMULATION Ì$-?Î INTER-BLOCK DELAY delay between character blocks transmitted to Host ÌCK3Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from .1 to 9.9 seconds delay disabled See par. 4.2.5 for details. 39 IBM 46XX IBM DATA FORMATTING 1. Read the Enter Configuration code ONCE, available at the top of each page. 2. Read configuration codes from the desired groups. 3. 40 = Default value Read the Exit and Save Configuration code ONCE, available at the top of each page. Enter Configuration Ì$+;Î Exit and Save Configuration IBM 46xx Ì$-?Î IBM DATA FORMATTING conversion to Code 39 ÌGD0YÎ IBM Standard ÌGD1\Î mixed IBM Standard + Code 39 ÌGD2_Î See par. 4.3.1 for details. 41 DATA FORMAT NOT FOR PEN INTERFACES CODE IDENTIFIER CUSTOM CODE IDENTIFIER HEADER TERMINATOR FIELD ADJUSTMENT FIELD ADJ. CHARACTER CODE LENGTH TX CHARACTER REPLACEMENT 1. Read the Enter Configuration code ONCE, available at the top of each page. 2. Read configuration codes from the desired groups. 3. 42 = Read the code and follow the procedure given = Default value Read the Exit and Save Configuration code ONCE, available at the top of each page. DATA FORMAT CODE IDENTIFIER TABLE CODE 2/5 interleaved 2/5 industrial 2/5 normal 5 bars 2/5 matrix 3 bars EAN 8 EAN 13 UPC A UPC E EAN 8 with 2 ADD ON EAN 8 with 5 ADD ON EAN 13 with 2 ADD ON EAN 13 with 5 ADD ON UPC A with 2 ADD ON UPC A with 5 ADD ON UPC E with 2 ADD ON UPC E with 5 ADD ON Code 39 Code 39 Full ASCII CODABAR ABC CODABAR Code 128 EAN 128 ISBT 128 Code 93 CIP/39 CIP/HR Code 32 MSI Plessey Standard Plessey Anker Telepen Delta IBM Code 11 Code 16K Code 49 RSS Expanded Linear and Stacked RSS Limited RSS 14 Linear and Stacked AIM STANDARD DATALOGIC STANDARD ]Iy ]Xy ]Sy ]Xy ]E4 ]E0 ]Xy ]Xy ]E5 ]E6 ]E1 ]E2 ]Xy ]Xy ]Xy ]Xy ]Ay ]Ay ]Fy ]Xy ]Cy ]Cy ] C4 ]Gy ]Xy ]Xy ]Xy ]My ]P0 ]P1 ]X0 ]X0 ]Hy ]K0 ]Ty ]e0 ]e0 ]e0 N P O Q A B C D J K L M F G H I V W R S T k f U Y e X Z a o d c b p q t v u Custom 43 DATA FORMAT AIM standard identifiers are not defined for all codes: the X identifier is assigned to the code for which the standard is not defined. The y value depends on the selected options (check digit tested or not, check digit tx or not, etc.). When customizing the Datalogic Standard code identifiers, 1 or 2 identifier characters can be defined for each code type. If only 1 identifier character is required, the second character must be selected as FF (disabled). The code identifier can be singly disabled for any code by simply selecting FF as the first identifier character. Write in the Custom character identifiers in the table above for your records. 44 Enter Configuration Ì$+;Î Exit and Save Configuration DATA FORMAT Ì$-?Î CODE IDENTIFIER disable ÌEB0SÎ Datalogic standard ÌEB1VÎ AIM standard ÌEB2YÎ custom ÌEB3\Î 45 Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î DATA FORMAT CUSTOM CODE IDENTIFIER define custom code identifier(s) ÌEH/Î Read the above code. (Code Identifiers default to Datalogic standard, see table on previous page). Select the code type from the code table in Appendix B for the identifier you want to change. You can define 1 or 2 identifier characters for each code type. If only 1 identifier character is required, the second character must be selected as FF (disabled). Read the hexadecimal value corresponding to the character(s) you want to define as identifiers for the code selected in step : valid characters are in the range 00-FD. Example: To define Code 39 Code Identifier = @ define custom code identifier(s) Read 46 ÌEH/Î Code 39 + ÌVWÎ + 40 + FF Enter Configuration Ì$+;Î Exit and Save Configuration Ì$-?Î DATA FORMAT HEADER no header ÌEA00*Î one character header ÌEA01.Î two character header ÌEA022Î three character header ÌEA036Î four character header ÌEA04:Î five character header ÌEA05>Î six character header ÌEA06BÎ seven character header ÌEA07FÎ eight character header ÌEA08JÎ After selecting one of the desired Header codes, read the character(s) from the HEX table. Valid characters are in the range 00-FE. Example: four character header + 41 + 42 + 43 + 44 = Header ABCD For more details see par. 4.4.1. 47 Enter Configuration Ì$+;Î Exit and Save Configuration Ì$-?Î DATA FORMAT TERMINATOR no terminator ÌEA10-Î one character terminator ÌEA111Î two character terminator ÌEA125Î three character terminator ÌEA139Î four character terminator ÌEA14=Î five character terminator ÌEA15AÎ six character terminator ÌEA16EÎ seven character terminator ÌEA17IÎ eight character terminator ÌEA18MÎ After selecting one of the desired Header codes, read the character(s) from the HEX table. Valid characters are in the range 00-FE. Example: two character terminator + 0D + 0A = Terminator CR LF For more details see par. 4.4.1. 48 Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î DATA FORMAT FIELD ADJUSTMENT disable field adjustment ÌEF0[Î Field adjustment allows a number of characters n, to be added to or subtracted from the barcode read. The adjustment can be different for each enabled code type. To define the field adjustment: Read the enable field adjustment code: enable field adjustment ÌEF+Î Select the code type from the Code Identifier Table in Appendix B. Select the type of adjustment to perform: right addition Ì01Î left addition Ì12Î right deletion Ì23Î left deletion Ì34Î Read a number in the range 01 - 32 from the Hex/Numeric Table to define how many characters to add or delete: Conditions: Adjustment is only performed on the barcode data, the Code Identifier and Code Length Transmission fields are not modified by the field adjustment parameter. If the field setting would subtract more characters than exist in the barcode, the subtraction will take place only to code length 0. You can set up to a maximum of 10 different field adjustments on the same barcode family or on different barcode families. Example: To add 4 characters to the right of Standard Code 39 Codes: enable field adjustment Read ÌEF+Î Code 39 + ÌVWÎ right addition + Ì01Î + 04 49 Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î FIELD ADJUSTMENT CHARACTER Read the field adjustment character code: field adjustment character ÌEG-Î Read the hexadecimal value corresponding to the character you want to use for field adjustment. Valid characters are in the range 00-FE. Example: To define the field adjustment character = A: field adjustment character Read + 41 CODE LENGTH TX code length not transmitted ÌEE0YÎ code length transmitted in variable-digit format ÌEE1\Î code length transmitted in fixed 4-digit format ÌEE2_Î The code length is transmitted in the message after the Headers and Code Identifier characters. The code length is calculated after performing any field adjustment operations. 50 Enter Configuration Ì$+;Î Exit and Save Configuration DATA FORMAT Ì$-?Î CHARACTER REPLACEMENT disable character replacement ÌEO0mÎ This parameter allows up to three characters to be replaced from the barcode read. These substitutions are stored in memory. To define each character replacement: Read one of the following character replacement codes: first character replacement ÌEO1pÎ second character replacement ÌEO2sÎ third character replacement ÌEO3vÎ From the Code Identifier Table in Appendix B, read the Code Identifier for the desired code family. 0 = character replacement will be effective for all code families. From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE) which identifies the character to be replaced. From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE) which identifies the new character to replace. FF = the character to be replaced will be substituted with no character, that is, it will be removed from the code. 51 Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î DATA FORMAT Example: The following strings define: 1. First Character Replacement: substitution in Code 39 barcodes of all occurrences of the 0 character with the 1 character. 2. Second Character Replacement: substitution in Code 39 barcodes of all occurrences of the A character with the B character. first character replacement Code 39 ÌEO1pÎ + ÌVWÎ + ASCII characters corresponding to the HEX value for character 0 30 ASCII characters corresponding to the HEX value for character 1 + 31 For Code 39 codes containing the string "0123", the contents transmitted will be "1123". second character replacement Code 39 ÌEO2sÎ + ÌVWÎ + ASCII characters corresponding to the HEX value for character A 41 ASCII characters corresponding to the HEX value for character B + 42 For Code 39 codes containing the string "ABCD", the contents transmitted will be "BBCD". 52 POWER SAVE SCAN RATE SLEEP STATE/USB SUSPEND ENTER SLEEP TIMEOUT STANDBY 1. Read the Enter Configuration code ONCE, available at the top of each page. 2. Read configuration codes from the desired groups. 3. = Read the code and follow the procedure given = Default value Read the Exit and Save Configuration code ONCE, available at the top of each page. 53 Enter Configuration Ì$+;Î Exit and Save Configuration POWER SAVE Ì$-?Î SCAN RATE CCD Readers ONLY quarter ÌBT0tÎ half ÌBT1wÎ maximum ÌBT2zÎ A lower scan rate reduces power consumption but can lengthen reading response time. SLEEP STATE/USB SUSPEND ONLY Devices with Button/Trigger disable ÌBQ0nÎ enable ÌBQ1qÎ See par. 4.5.1 for details. 54 Enter Configuration Ì$+;Î Exit and Save Configuration POWER SAVE Ì$-?Î ENTER SLEEP TIMEOUT ONLY Devices with Button/Trigger enter sleep timeout ÌBR@Î Read 2 numbers in the range 00-99: 00 = Enter Sleep state immediately 01-99 = corresponds to a max. 9.9 sec. delay before entering the Sleep state. See par. 4.5.2 for details. STANDBY ONLY for CCD Devices disable ÌBM1iÎ optimize for reading speed enable ÌBM0fÎ optimize for low power consumption See par. 4.5.3 for details. 55 READING PARAMETERS HAND-HELD OPERATION STAND OPERATION TRIGGER SIGNAL TRIGGER-OFF TIMEOUT FLASH MODE READS PER CYCLE SAFETY TIME BEEPER INTENSITY BEEPER TONE BEEPER TYPE BEEPER LENGTH GOOD READ SPOT DURATION STAND RECOGNITION BEEP AUTOMATIC OPERATION AIMING LIGHT AIMING SYSTEM 1. Read the Enter Configuration code ONCE, available at the top of each page. 2. Read configuration codes from the desired groups. 3. 56 = Read the code and follow the procedure given = Default value Read the Exit and Save Configuration code ONCE, available at the top of each page. Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î READING PARAMETERS HAND-HELD OPERATION hardware trigger ÌBK1eÎ software trigger ÌBK0bÎ always on ÌBK3kÎ automatic ÌBK2hÎ * hardware trigger ready ÌBK4nÎ = default value for devices with trigger = default value for devices without trigger * = only for CCD readers with trigger = only for CCD readers For Automatic Hand-Held or Stand Operation, the Safety Time parameter is forced to no code consecutive reading (00). See par. 4.6.1 for details STAND OPERATION ONLY Devices with Stand Recognition Beep hardware trigger ÌBU3ÃÎ software trigger ÌBU1yÎ always on ÌBU2|Î automatic ÌBU0vÎ See par. 4.6.1 for details 57 Enter Configuration Ì$+;Î Exit and Save Configuration READING PARAMETERS Ì$-?Î HARDWARE TRIGGER SIGNAL ONLY Devices with Button/Trigger trigger active level ÌBA0NÎ trigger active pulse ÌBA1QÎ See par. 4.6.2 for details TRIGGER-OFF TIMEOUT ONLY Devices with Button/Trigger trigger-off timeout ÌBD$Î Read 2 numbers in the range 00-99: 00 = disables the trigger-off timeout 01-99 = corresponds to a max. 99-sec. delay after the trigger press to allow the reader to turn off automatically. trigger-off timeout disabled See par. 4.6.3 for details. 58 Enter Configuration Ì$+;Î Exit and Save Configuration READING PARAMETERS Ì$-?Î FLASH MODE "FLASH" ON duration "FLASH" OFF duration ÌBB0PÎ ÌBB1SÎ Read 2 numbers in the range 01-99: 01 to 99 = from .1 to 9.9 seconds. Flash-ON = 1 sec. Flash-OFF = 0.6 sec READS PER CYCLE one read per cycle ÌBC0RÎ multiple reads per cycle ÌBC1UÎ See par. 4.6.4 for details. 59 Enter Configuration Ì$+;Î Exit and Save Configuration READING PARAMETERS Ì$-?Î SAFETY TIME safety time ÌBE&Î Limits same code consecutive reading. Read 2 numbers in the range 00-99: 00 = no same code consecutive reading until reader is removed (no decoding) for at least 400 ms. 01-99 = timeout from .1 to 9.9 seconds before a consecutive read on same code. safety time = 0.5 sec See par. 4.6.5 for details. BEEPER INTENSITY beeper off * ÌBG0ZÎ low intensity ÌBG1]Î medium intensity ÌBG2`Î high intensity ÌBG3cÎ * 60 This sets the beeper OFF for data entry, while for all other beeper signals it has the meaning “very low intensity”. The Beeper Intensity parameter is effective for all operating conditions described in par. 1.1. Enter Configuration Ì$+;Î Exit and Save Configuration READING PARAMETERS Ì$-?Î BEEPER TONE tone 1 ÌBH0\Î tone 2 ÌBH1_Î tone 3 ÌBH2bÎ tone 4 ÌBH3eÎ BEEPER TYPE monotone ÌBJ0`Î bitonal ÌBJ1cÎ BEEPER LENGTH long ÌBI0^Î short ÌBI1aÎ 61 Enter Configuration Ì$+;Î Exit and Save Configuration READING PARAMETERS Ì$-?Î GOOD READ SPOT DURATION CCD Long Range Readers ONLY disable ÌBV0xÎ short ÌBV1{Î medium ÌBV2~Î long ÌBV3ÅÎ STAND RECOGNITION BEEP ONLY Readers with Stand Recognition disable ÌBa0'Î enable ÌBa1*Î 62 Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î READING PARAMETERS AUTOMATIC OPERATION AIMING LIGHT CCD Long Range Readers ONLY disable ÌBb0)Î enable ÌBb1,Î See par. 4.6.6 for details. AIMING SYSTEM Laser Readers ONLY disable ÌBX0|Î 300 ms ÌBX1ÃÎ 500 ms ÌBX2ÆÎ 1 sec ÌBX3ÉÎ See par. 4.6.7 for details. 63 DECODING PARAMETERS INK SPREAD OVERFLOW CONTROL INTERDIGIT CONTROL DECODING SAFETY PUZZLE SOLVER™ Before changing these parameter values read the descriptions in par. 4.7. CAUTION 1. 2. 3. 64 Read the Enter Configuration code ONCE, available at the top of each page. Read configuration codes from the desired groups. = Default value Read the Exit and Save Configuration code ONCE, available at the top of each page. Enter Configuration Ì$+;Î Exit and Save Configuration DECODING PARAMETERS Ì$-?Î INK SPREAD disable ÌAX0{Î enable ÌAX1~Î See par. 4.7.1 for details. OVERFLOW CONTROL disable ÌAW1|Î enable ÌAW0yÎ See par. 4.7.2 for details. 65 Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î DECODING PARAMETERS INTERDIGIT CONTROL disable ÌAV0wÎ enable ÌAV1zÎ See par. 4.7.3 for details. DECODING SAFETY one read ÌED0WÎ (decoding safety disabled) two reads ÌED1ZÎ three reads ÌED2]Î four reads ÌED3`Î Required number of good reads before accepting code. 66 Enter Configuration Exit and Save Configuration Ì$+;Î DECODING PARAMETERS Ì$-?Î PUZZLE SOLVER™ disable ÌAU0uÎ enable ÌAU1xÎ In the case of damaged or poorly printed codes, this parameter allows reading multiple parts of the single code to reconstruct it. To read codes using this technology, simply move the reader over the code so that each line of the code is scanned. Conditions: This parameter is only valid for the following codes: EAN 8 without Add-on EAN 13 without Add-on Code 128 Code 39 UPC A without Add-on For Code 39, Check digit control without transmission is forced. PuzzleSolver is disabled when code ISBT 128 is enabled. 67 CODE SELECTION EAN/UPC FAMILY 2/5 FAMILY CODE 39 FAMILY CODE 128 FAMILY CODABAR FAMILY CODE 93 MSI PLESSEY TELEPEN DELTA IBM CODE 11 CODE 16K CODE 49 RSS CODES 1. Read the Enter Configuration code ONCE, available at the top of each page. 2. Read configuration codes from the desired groups. 3. 68 = Read the code and follow the procedure given = Default value Read the Exit and Save Configuration code ONCE, available at the top of each page. Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î DISABLES ALL CODE FAMILIES ÌAZ0ÃÎ The reader allows up to 5 code selections. This does not limit the number of CODES enabled to 5, as it depends on the code family. NOTE SINGLE SELECTIONS = ONE combination code from the EAN family ONE code from the 2/5 family Example 5 code selections: 1. 2/5 Interleaved 2. 2/5 Industrial 3. Code 128 + EAN 128 4. Code 39 Full ASCII + Code 32 5. UPC A/UPC E In this section all SINGLE code selections are underlined and in bold. 69 Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î EAN/UPC FAMILY disable the family ÌAA0MÎ Read the desired family code Note: Since the EAN/UPC without ADD ON code selection is enabled by default, to correctly enable another selection, first disable the family. EAN 8/EAN 13/UPC A/UPC E with and without ADD ON ÌAA8eÎ WITHOUT ADD ON EAN 8/EAN 13/UPC A/UPC E ÌAA1PÎ EAN 8/EAN 13 ÌAA3VÎ UPC A/UPC E ÌAA4YÎ 70 Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION WITH ADD ON 2 AND 5 EAN 8/EAN 13/UPC A/UPC E ÌAA5\Î EAN 8/EAN 13 ÌAA6_Î UPC A/UPC E ÌAA7bÎ WITH ADD ON 2 ONLY EAN 8/EAN 13 ÌAAK7Î UPC A/UPC E ÌAAM=Î WITH ADD ON 5 ONLY EAN 8/EAN 13 ÌAAL:Î UPC A/UPC E ÌAAN@Î 71 Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION EAN/UPC CHECK DIGIT TX SELECTIONS For each code type in this family you can choose to transmit the check digit or not CHECK DIGIT TRANSMISSION NO CHECK DIGIT TRANSMISSION EAN 8 ÌAAG1oÎ EAN 8 ÌAAG0kÎ EAN 13 ÌAAH1rÎ EAN 13 ÌAAH0nÎ UPC A ÌAAI1uÎ UPC A ÌAAI0qÎ UPC E ÌAAJ1xÎ UPC E ÌAAJ0tÎ 72 Enter Configuration Ì$+;Î Exit and Save Configuration CODE SELECTION Ì$-?Î CONVERSION OPTIONS UPC E to UPC A conversion ÌAAAÄÎ UPC E to EAN 13 conversion ÌAABÇÎ UPC A to EAN 13 conversion ÌAACÊÎ EAN 8 to EAN 13 conversion ÌAAD"Î Enable only ISBN conversion ÌAP1nÎ Enable only ISSN conversion ÌAP2qÎ Enable both ISBN and ISSN conversion ÌAP3tÎ Disable both ISBN and ISSN conversion ÌAP0kÎ 73 Enter Configuration Ì$+;Î Exit and Save Configuration Ì$-?Î CODE SELECTION 2/5 FAMILY disables the family ÌAC0QÎ Read the desired family code Read a check digit selection Interleaved 2/5 ÌAC1TÎ CHECK DIGIT TABLE no check digit control Ì12Î Normal 2/5 (5 Bars) ÌAC2WÎ check digit control and transmission Ì23Î Industrial 2/5 (IATA) ÌAC3ZÎ check digit control without transmission Ì34Î Matrix 2/5 (3 Bars) ÌAC4]Î Read 4 numbers for the code length The pharmaceutical code below is part of the 2/5 family but has no check digit or code length selections. Code CIP/HR ÌAC5`Î French pharmaceutical code 74 where: First 2 digits = minimum code length. Second 2 digits = maximum code length. The maximum characters. code length is 99 The minimum code length must always be less than or equal to the maximum. Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only. Enter Configuration Ì$+;Î Exit and Save Configuration CODE SELECTION Ì$-?Î CODE 39 FAMILY disables the family ÌAB0OÎ Read the desired family code Read a check digit selection CHECK DIGIT TABLE Standard Code 39 ÌAB1RÎ Full ASCII Code 39 ÌAB2UÎ no check digit control Ì12Î check digit control and transmission Ì23Î check digit control without transmission Ì34Î 75 Enter Configuration Ì$+;Î Exit and Save Configuration CODE SELECTION Ì$-?Î The pharmaceutical codes below are part of the Code 39 family but have no check digit selections. Code CIP39 ÌAB3XÎ French pharmaceutical code Code 32 ÌAB4[Î Italian pharmaceutical code CODE LENGTH (optional) The code length selection is valid for the entire Code 39 family Read the code + 4 numbers for the code length where: First 2 digits = minimum code length. Second 2 digits = maximum code length. set code length ÌAB*=Î The maximum code length is 99 characters. The minimum code length must always be less than or equal to the maximum. Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only. 76 Enter Configuration Ì$+;Î Exit and Save Configuration CODE SELECTION Ì$-?Î CODE 128 FAMILY disables the family ÌAI0]Î Read the desired family code Code 128 ÌAI11=Î control without transmission of check digit EAN 128 ÌAI21@Î control without transmission of check digit Transmit GS Before Code Code EAN 128 uses the ASCII <GS> character to separate a variable length code field from the next code field. This character can also be transmitted before the code. disable ÌEQ0qÎ enable ÌEQ1tÎ If the <GS> character has been modified in the Character Replacement parameter, the new character is affected by this command. 77 Enter Configuration Ì$+;Î Exit and Save Configuration CODE SELECTION Ì$-?Î ISBT 128 ÌAI31CÎ Enabling ISBT 128 automatically disables Puzzle Solver™. CODE LENGTH (optional) The code length selection is valid for the entire Code 128 family. Read the code + 4 numbers for the code length where: set code length ÌAILJÎ First 2 digits = minimum code length Second 2 digits = maximum code length The maximum code length is 99 characters. The minimum code length must always be less than or equal to the maximum. Examples: 0199 = variable from 1 to 99 digits in the code. 1010= 10 digit code length only. The length is calculated on the output string. CODE 93 disables the code ÌAK0aÎ Code 93 ÌAK1dÎ control without transmission of check digit 78 Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION CODABAR FAMILY disables the family ÌAD0SÎ Read the desired equality control code Read a start/stop transmission selection START/STOP CHARACTER TRANSMISSION Standard Codabar ÌAD113Î no start/stop character equality control no transmission Ì12Î Standard Codabar ÌAD127Î start/stop character equality control transmission Ì23Î The Codabar ABC code below uses a fixed start/stop character transmission selection. Codabar ABC ÌAD212)Î no start/stop character equality control but transmission. 79 Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION Codabar ABC Forced Concatenation enable Codabar ABC with forced concatenation ÌAD2321Î non start/stop character equality control but transmission CODE LENGTH (optional) The code length selection is valid for the entire Codabar family Read the code + 4 numbers for the code length where: First 2 digits = minimum code length. Second 2 digits = maximum code length. set code length ÌAD*AÎ The maximum code length is 99 characters. The minimum code length must always be less than or equal to the maximum. Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only. START/STOP CHARACTER CASE IN TRANSMISSION The start/stop character case selections below are valid for the entire Codabar family: transmit start/stop characters in lower case ÌADA0_Î transmit start/stop characters in upper case ÌADA1cÎ 80 Enter Configuration Ì$+;Î Exit and Save Configuration CODE SELECTION Ì$-?Î MSI disables the family ÌAE0UÎ Enable the code by selecting one of the check digit selections. no check digit control ÌAE1XÎ MOD10 check digit control no check digit transmission ÌAE2[Î MOD10 check digit control check digit transmission ÌAE3^Î MOD11 - MOD10 check digit control no check digit transmission ÌAE4aÎ MOD11 - MOD10 check digit control check digit transmission ÌAE5dÎ MOD10 - MOD10 check digit control no check digit transmission ÌAE6gÎ MOD10 - MOD10 check digit control check digit transmission ÌAE7jÎ 81 Enter Configuration Ì$+;Î Exit and Save Configuration CODE SELECTION Ì$-?Î PLESSEY disables the family ÌAF0WÎ Enable the code by selecting one of the check digit selections. Standard Plessey no check digit control ÌAF117Î check digit control check digit transmitted ÌAF12;Î check digit control check digit not transmitted ÌAF13?Î Anker Plessey no check digit control ÌAF21:Î check digit control check digit transmitted ÌAF22>Î check digit control check digit not transmitted ÌAF23BÎ 82 Enter Configuration Ì$+;Î Exit and Save Configuration CODE SELECTION Ì$-?Î TELEPEN disables the family ÌAL0cÎ Enable the code by selecting one of the check digit selections. Numeric Telepen no check digit control ÌAL11CÎ check digit control check digit transmitted ÌAL12GÎ check digit control check digit not transmitted ÌAL13KÎ Alphanumeric Telepen no check digit control ÌAL21FÎ check digit control check digit transmitted ÌAL22JÎ check digit control check digit not transmitted ÌAL23NÎ 83 Enter Configuration Ì$+;Î Exit and Save Configuration CODE SELECTION DELTA IBM disables the family ÌAH0[Î Enable the code by selecting one of the check digit selections. no check digit control ÌAH1^Î Type 1 check digit control ÌAH2aÎ Type 2 check digit control ÌAH3dÎ 84 Ì$-?Î Enter Configuration Ì$+;Î Exit and Save Configuration CODE SELECTION Ì$-?Î CODE 11 disables the family ÌAG0YÎ Enable the code by selecting one of the check digit selections. no check digit control ÌAG1\Î Type C check digit control check digit transmitted ÌAG21<Î Type C check digit control check digit not transmitted ÌAG22@Î Type K check digit control check digit transmitted ÌAG31?Î Type K check digit control check digit not transmitted ÌAG32CÎ Type C and Type K check digit control check digits transmitted ÌAG41BÎ Type C and Type K check digit control check digits not transmitted ÌAG42FÎ 85 Enter Configuration Ì$+;Î Exit and Save Configuration CODE SELECTION Ì$-?Î CODE 16K disables the code ÌAJ0_Î Code 16K ÌAJ1bÎ To read stacked codes, simply move the reader over the code so that each line of the code is scanned. CODE 49 disables the code ÌAM0eÎ Code 49 ÌAM1hÎ To read stacked codes, simply move the reader over the code so that each line of the code is scanned. 86 Enter Configuration Ì$+;Î Exit and Save Configuration CODE SELECTION Ì$-?Î RSS CODES disables the family ÌAQ0mÎ DISABLE CODE ENABLE CODE disable RSS Expanded Linear and Stacked ÌAQ10IÎ enable RSS Expanded Linear and Stacked ÌAQ11MÎ disable RSS Limited ÌAQ20LÎ enable RSS Limited ÌAQ21PÎ disable RSS 14 Linear and Stacked ÌAQ30OÎ enable RSS 14 Linear and Stacked ÌAQ31SÎ To read the stacked version of these codes, simply move the reader over the code so that each line of the code is scanned. 87 ADVANCED FORMATTING CONCATENATION ADVANCED FORMATTING Please follow the setup procedure carefully for these parameters. NOTE 1. 2. Read the Enter Configuration code ONCE, available at the top of page . Read configuration codes precisely following the numbered procedure given. 3. 88 = Read the code and follow the procedure given = Default value Read the Exit and Save Configuration code ONCE, available at the top of page. Enter Configuration Ì$+;Î Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î CONCATENATION disable ÌEI0aÎ enable ÌEI1dÎ Permits the concatenation of two codes defined by code type and length. It is possible to set a timeout for the second code reading and to define code transmission if the timeout expires. The order of transmission is CODE 1-CODE 2. Define Concatenation 1 Code 1 code ID ÌEK0eÎ Read the code type from the Code Identifier Table beginning in Appendix B. code length ÌEL0gÎ Read a number in the range 01-99 from the Hex/Numeric Table. 89 Exit and Save Configuration ADVANCED FORMATTING 2 Ì$-?Î Code 2 code ID ÌEK1hÎ Read the code type from the Code Identifier Table beginning in Appendix B. code length ÌEL1jÎ Read a number in the range 01-99 from the Hex/Numeric Table. 3 Concatenation Result Code ID use code 1 ID ÌEN0kÎ use code 2 ID ÌEN1nÎ Since you can concatenate codes from different families, you must select the Code ID character of the resulting code. The Code ID character will be sent in the output message only if it is enabled according to the Code Identifier selection (Datalogic, AIM, or Custom). 4 Concatenation Timeout timeout ÌEJ3Î Read two numbers in the range 00 to 99 00= no timeout 01-99 = timeout from 1 to 99 seconds Define the timeout, which determines the valid waiting period between the two codes, in order to accept concatenation. If the timeout expires, the resulting action will be based on the following selection. 90 Exit and Save Configuration ADVANCED FORMATTING 5 Ì$-?Î Transmission after Timeout no code transmitted after timeout ÌEM0iÎ only code 1 transmitted (if read) after timeout ÌEM1lÎ only code 2 transmitted (if read) after timeout ÌEM2oÎ either code 1 or code 2 transmitted after timeout ÌEM3rÎ 91 ADVANCED FORMATTING ADVANCED FORMATTING Advanced formatting has been designed to offer you complete flexibility in changing the format of barcode data before transmitting it to the host system. This formatting will be performed when the barcode data meets certain criteria which you will define in the following procedure. Up to 4 advanced code management formats can be defined and saved in memory. For each format you must complete the entire configuration procedure: Read the Enter Configuration Command Step 1 Begin Format Definition 1, 2, 3, or 4 Steps 2 - 4 Define Match Code Conditions Step 5 Divide Code into Fields Step 6 Define Code Fields Steps 7 - 8 Add up to 2 Additional Fields Step 9 Define Field Transmission Step 10 Apply or Not Standard Message Formatting Step 11 End Format Definition 1, 2, 3, or 4 YES Define another? NO Enable Advanced Formats 1, 2, 3, 4 Define No Match Result Read the Exit and Save Configuration Command 92 Enter Configuration Ì$+;Î Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î Begin Format Definition 1 begin Format 1 definition ÌHA0TÎ begin Format 2 definition ÌHA1WÎ begin Format 3 definition ÌHA2ZÎ begin Format 4 definition ÌHA3]Î 2 Match Code Type match code type ÌHB&Î Read the above code + the code type to match from the Code Identifier Table in Appendix B. OR any code type ÌHB0VÎ 3 Match Code Length match code length ÌHC(Î Read the above code + two numbers in the range 01 to 99 for the exact code length. OR any code length ÌHC001Î 93 Exit and Save Configuration ADVANCED FORMATTING 4 Ì$-?Î Match with Predefined Characters no match ÌHD0HE00ÄÎ OR match with 1 character ÌHD1]Î match with a 2-character string ÌHD2`Î match with a 3-character string ÌHD3cÎ match with a 4-character string ÌHD4fÎ After selecting the predefined match code, read the character(s) from the HEX table. Range of characters = 01-FE. Example: Match code with the 2-character predefined string = "@@". Match with a 2-character string Read AND + 40 + 40 position of first character in predefined string ÌHE,Î Read the above code + two numbers in the range 01 to 99 representing the character position in the code where the first character of the predefined string must be found. Read 00 if the match string can be found in any character position. 94 Exit and Save Configuration ADVANCED FORMATTING 5 Ì$-?Î Divide Code into Fields divide code into fields ÌHF.Î Read one number in the range 1 to 5 to divide the code into fields. 6 Define Code Fields define code fields Each code field length can be set by either: a) defining a field separator character to be found in the code itself. In this case you can choose to discard the code separator character or include it as the last character of the field. OR BY b) defining a match character to be found consecutively repeated in the code itself. In this case the field ends with the first character that does not match. OR BY c) specifying a specific character length up to the maximum of 99 characters. OR BY d) selecting the last field as variable length (if any). You must define the same number of fields as selected in step 5, including fields that will not be transmitted. 95 Exit and Save Configuration Ì$-?Î ADVANCED FORMATTING DEFINE FIELD 1 BY: EITHER field separator a) ÌHG0`Î Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator Ì01Î Ì12Î OR match character b) ÌHG3iÎ Read the match character from the HEX table. Range of characters = 01-FE. OR field length c) ÌHG1cÎ Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length) d) ÌHG2fÎ AND Field 1 Terminators no field terminators ÌHH0bÎ 1 field terminator ÌHH1eÎ 2 field terminators ÌHH2hÎ Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE. For readers using Wedge interface, all values from 9C to FE send the Space character. 96 Exit and Save Configuration Ì$-?Î ADVANCED FORMATTING DEFINE FIELD 2 BY: EITHER field separator a) ÌHG0`Î Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator Ì01Î Ì12Î OR match character b) ÌHG3iÎ Read the match character from the HEX table. Range of characters = 01-FE. OR field length c) ÌHG1cÎ Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length) d) ÌHG2fÎ AND Field 2 Terminators no field terminators ÌHH0bÎ 1 field terminator ÌHH1eÎ 2 field terminators ÌHH2hÎ Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE. For readers using Wedge interface, all values from 9C to FE send the Space character. 97 Exit and Save Configuration Ì$-?Î ADVANCED FORMATTING DEFINE FIELD 3 BY: EITHER field separator a) ÌHG0`Î Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator Ì01Î Ì12Î OR match character b) ÌHG3iÎ Read the match character from the HEX table. Range of characters = 01-FE. OR field length c) ÌHG1cÎ Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length) d) ÌHG2fÎ AND Field 3 Terminators no field terminators ÌHH0bÎ 1 field terminator ÌHH1eÎ 2 field terminators ÌHH2hÎ Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE. For readers using Wedge interface, all values from 9C to FE send the Space character. 98 Exit and Save Configuration Ì$-?Î ADVANCED FORMATTING DEFINE FIELD 4 BY: EITHER field separator a) ÌHG0`Î Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator Ì01Î Ì12Î OR match character b) ÌHG3iÎ Read the match character from the HEX table. Range of characters = 01-FE. OR field length c) ÌHG1cÎ Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length) d) ÌHG2fÎ AND Field 4 Terminators no field terminators ÌHH0bÎ 1 field terminator ÌHH1eÎ 2 field terminators ÌHH2hÎ Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE. For readers using Wedge interface, all values from 9C to FE send the Space character. 99 Exit and Save Configuration Ì$-?Î ADVANCED FORMATTING DEFINE FIELD 5 BY: EITHER field separator a) ÌHG0`Î Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator Ì01Î Ì12Î OR match character b) ÌHG3iÎ Read the match character from the HEX table. Range of characters = 01-FE. OR field length c) ÌHG1cÎ Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length) d) ÌHG2fÎ AND Field 5 Terminators no field terminators ÌHH0bÎ 1 field terminator ÌHH1eÎ 2 field terminators ÌHH2hÎ Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE. For readers using Wedge interface, all values from 9C to FE send the Space character. 100 Exit and Save Configuration ADVANCED FORMATTING 7 Ì$-?Î First Additional Fixed Field no fixed field ÌHI0dÎ 1 character fixed field ÌHI1gÎ 2 character fixed field ÌHI2jÎ 3 character fixed field ÌHI3mÎ 4 character fixed field ÌHI4pÎ 5 character fixed field ÌHI5sÎ 6 character fixed field ÌHI6vÎ After selecting one of the Additional Fixed Field codes, read the corresponding character(s) from the HEX table. Range of characters = 01-FE. For readers using Wedge interface, all values from 9C to FE send the Space character. Example: 4 Character Fixed Field + 4D + 41 + 49 + 4E = MAIN 101 Exit and Save Configuration ADVANCED FORMATTING 8 Ì$-?Î Second Additional Fixed Field no fixed field ÌHJ0fÎ 1 character fixed field ÌHJ1iÎ 2 character fixed field ÌHJ2lÎ 3 character fixed field ÌHJ3oÎ 4 character fixed field ÌHJ4rÎ 5 character fixed field ÌHJ5uÎ 6 character fixed field ÌHJ6xÎ After selecting one of the Additional Fixed Field codes, read the corresponding character(s) from the HEX table. Range of characters = 01-FE. For readers using Wedge interface, all values from 9C to FE send the Space character. Example: 3 Character Fixed Field + 53 + 45 + 54 = 102 SET Exit and Save Configuration ADVANCED FORMATTING 9 Ì$-?Î Field Transmission number of fields to transmit ÌHK8Î Read one number in the range 1 to 7 for the number of fields to transmit. Include only fields to be transmitted. Field Order Transmission Read the codes corresponding to the fields to transmit in the order in which they are to be transmitted. A field can be transmitted more than once. See example. field 1 Ì12Î field 2 Ì23Î field 3 Ì34Î field 4 Ì45Î field 5 Ì56Î additional field 1 Ì67Î additional field 2 Ì78Î Example: The barcode is divided into 3 defined fields plus 1 additional fixed field. Transmit in the order: Field 2, Additional Field 1, Field 1, Field 2. Number of Fields to Transmit Field 2 +4+ Additional Field 1 + Field 1 + Field 2 + 103 Exit and Save Configuration ADVANCED FORMATTING 10 Ì$-?Î Standard Formatting do not apply standard formatting ÌHL0jÎ apply standard formatting ÌHL1mÎ After performing Advanced Formatting on the barcode read, Standard Formatting (Headers, Code Length, Code ID, Terminators) can be applied to the message to be transmitted. 11 End Format Definition end Format 1 definition ÌHM0lÎ end Format 2 definition ÌHM1oÎ end Format 3 definition ÌHM2rÎ end Format 4 definition ÌHM3uÎ 104 Enter Configuration Ì$+;Î Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î Enable Advanced Format no Advanced Formats enabled ÌHN0nÎ Advanced Format 1 enable ÌHN11NÎ disable ÌHN10JÎ Advanced Format 2 enable ÌHN21QÎ disable ÌHN20MÎ Advanced Format 3 enable ÌHN31TÎ disable ÌHN30PÎ Advanced Format 4 enable ÌHN41WÎ disable ÌHN40SÎ 105 Enter Configuration Ì$+;Î Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î No Match Result clear data - no transmission ÌHO0pÎ transmit data using standard format ÌHO1sÎ This selection determines the action to be taken when codes read do not conform to the advanced format requisites (no match). 106 Codes not matching can be ignored, cleared from memory and not transmitted. Codes not matching can be transmitted using the Standard formatting (Headers, Code Length, Code ID, Terminators). REFERENCES 4 REFERENCES 4.1 4.1.1 USB-COM AND RS232 PARAMETERS Handshaking Hardware handshaking: (RTS/CTS) The RTS line is activated by the decoder before transmitting a character. Transmission is possible only if the CTS line (controlled by the Host) is active. Signals at EIA levels RTS TX Transmitted data Transmitted data Host busy CTS RTS/CTS handshaking Software handshaking: (XON/XOFF) During transmission, if the Host sends the XOFF character (13 Hex), the decoder interrupts the transmission with a maximum delay of one character and only resumes when the XON character (11 Hex) is received. Transmitted data Transmitted data TX RX XOFF Host busy XON Host ready XON/XOFF handshaking 107 HHD II 4.1.2 ACK/NACK Protocol This parameter sets a transmission protocol in which the Host responds to the reader after every code transmitted. The Host sends an ACK character (06 HEX) in the case of good reception or the NACK character (15 HEX) requesting re-transmission, in the case of bad reception. If the reader does not receive an ACK or NACK, transmission is ended after the RX Timeout (see par. 4.1.4). Selection of the ACK/NACK protocol automatically disables FIFO buffering see par. 4.1.3. 4.1.3 FIFO This parameter determines whether data (barcodes) are buffered on a First In First Out basis allowing faster data collection in certain cases for example when using slow baud rates and/or hardware handshaking. If the FIFO buffering is enabled, codes are collected and sent out on the serial line in the order of acquisition. Several hundred characters can be collected (buffer full), after which the reader signals an error and discards any further codes until the transmission is restored. If the FIFO buffering is disabled, each code must be transmitted before another one can be read. 4.1.4 RX Timeout When the RS232 interface is selected, the Host can be used to configure the device by sending it command strings (see appendix A). This parameter can be used to automatically end data reception from the Host after the specified period of time. If no character is received from the Host, after the timeout expires, any incomplete string (any string not terminated by <CR>) is flushed from the device buffer. 108 REFERENCES 4.2 PEN PARAMETERS 4.2.1 Minimum Output Pulse This parameter sets the duration of the output pulse corresponding to the narrowest element in the barcode. In this way the code resolution is controlled by the signal sent to the decoder, independently of the physical resolution of the code read. The shortest pulse (200 s) corresponds to high-resolution code emulation and therefore a shorter transfer speed to the decoder (for decoders able to work on highresolution codes). Likewise, longer pulses correspond to low-resolution code emulation and therefore a longer transfer time to the decoder. 4.2.2 Conversion to Code 39 When using these readers it is possible to convert all codes to Code 39. By disabling this option the decoded codes will be transmitted in their original format; except for the following codes which are ALWAYS converted into Code 39 format: MSI, Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code 49 and RSS Codes. 4.2.3 Overflow This parameter generates a white space before the first bar and after the last bar of the code. The selections are as follows: narrow medium wide = space 10 times the minimum output pulse. = space 20 times the minimum output pulse. = space 30 times the minimum output pulse. 109 HHD II 4.2.4 Output and Idle Levels The following state diagrams describe the different output and idle level combinations for Pen emulation: idle bar OUTPUT: Normal space IDLE: Normal black white barcode output bar OUTPUT: Normal idle space IDLE: Inverted black white barcode output space OUTPUT: Inverted white idle bar IDLE: Normal black barcode output OUTPUT: Inverted white space idle bar IDLE: Inverted black barcode output Output and Idle Levels 4.2.5 Inter-Block Delay For the PEN Emulation interface, data are sent to the Host in fixed size blocks of 20 characters each. The inter-block delay parameter allows setting a delay between each block sent to the Host. 110 REFERENCES 4.3 4.3.1 IBM 46XX IBM Data Formatting (Transmission Format) The IBM 46xx Series cash register recognizes the following codes: EAN 8 / EAN13 / UPC A / UPC E with and without Add On Interleaved 2/5 Code 39 Codabar Code 128 Code 93 Normal 2/5 The transmission format of codes belonging to this set is specified by the protocol. As the reader allows a wider set of codes to be selected, the following formats are defined to offer the user all the reading possibilities of the Datalogic product. Conversion to Code 39 Format Data from any code selected may be transmitted. Each code is transmitted to the Host as Code 39. Any character not included in the standard Code 39 set will be replaced with a “Space” (20 Hex). IBM Standard Format Only codes belonging to the above mentioned set may be transmitted. Each code transmitted to the Host is recognized by the identifier requested by the protocol. If the selected code does not belong to this set, it wiII not be transmitted. Mixed IBM Standard + Code 39 Format Data from any code selected may be transmitted. For codes belonging to the above mentioned set, the “IBM Standard Format” is applied. The “Code 39’ Format applies to codes not belonging to this set. 111 HHD II 4.4 DATA FORMAT 4.4.1 Header/Terminator Selection The header/terminator selection is not effected by the reading of the restore default code. In fact, header and terminator default values depend on the interface selection: RS232 and USB-COM: WEDGE and USB-KBD: WEDGE ALT-MODE and USB-KBD-ALT-MODE: no header, terminator CR-LF no header, terminator ENTER no header, terminator CR These default values are always restored through the reading of the relative interface selection code, see chapter 2. For the WEDGE interface, the following extended keyboard values can also be configured: EXTENDED KEYBOARD TO HEX CONVERSION TABLE IBM AT IBM 3153 APPLE ADB IBM XT IBM 31xx, 32xx, 34xx, 37xx Wyse Digital HEX KEY KEY KEY KEY 83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A 9B ENTER TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 HOME END PG UP PG DOWN ESC CTRL (Right) Euro ENTER TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 ESC BACKSPACE HOME END PG UP PG DOWN ESC CTRL (Right) Space FIELD EXIT TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 ENTER RESET INSERT DELETE FIELD FIELD + ENTER (Paddle) PRINT RETURN TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 F15 F16 UP DOWN LEFT RIGHT ESC CTRL (Right) Space Space For all readers using Wedge interface, all values from 9C to FE send the Space character. 112 REFERENCES 4.4.2 Set Custom Extended Header/Terminator Keys The extended Header/Terminator keys for Wedge Interface users can be customized by defining them through a simple keyboard setting procedure. For example, the Numeric Keypad keys can be set for use as Headers or Terminators by substituting the default extended keys using this procedure. The type of computer or terminal must be selected before activating the keyboard setting command. Press and release a key to set it. Some characters may require more than one key pressed simultaneously during normal use (refer to the manual of your PC or terminal for keyboard use). The exact sequence must be indicated to the reader in this case pressing and releasing the different keys. Example: If one has to press the "Shift" and "4" keys simultaneously on the keyboard to transmit the character "$" to the video, to set the "$", press and release "Shift" then press and release "4". Each pressed and released key must generate an acoustic signal on the reader, otherwise repress the key. Never press more than one key at the same time, even if this corresponds to the normal use of your keyboard. Press "Backspace" to correct a wrong key entry. In this case the reader emits 2 beeps. Note: "CAPS LOCK" and "NUM LOCK" must be off before starting the keyboard setting procedure. "SHIFT" must be repressed for each character and cannot be substituted by "CAPS LOCK". 113 Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î Set Custom Extended Header/Terminator Keys ÌFB1WÎ Read the code above. If the first 4 KEYS (Shift, Alt, Ctrl, and Backspace) are not available on your keyboard, you can only substitute them with keys not used, or substitute them with each other. Keys 5 to 28 must be defined Press the desired keys in the following order: The reader signals the end of the procedure with 2 beeps indicating the keys have been registered. CUSTOM EXTENDED KEYBOARD SETTING TABLE Custom 114 Order HEX KEY 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A Shift Alt Ctrl Backspace REFERENCES 4.5 POWER SAVE 4.5.1 Sleep State/USB Suspend When using standard devices, this mode allows the P in the reader to enter a “Sleep” state for minimum power consumption. This command is only valid when hardware trigger type is selected. Before entering Sleep mode, the following are verified: no commands coming from Host no data being transmitted to Host Enter Sleep Timeout ended (see par. 4.5.2) It is possible to exit Sleep mode either by pressing the button/trigger or by inserting the reader into the Stand (only for devices with Stand Recognition Beep). Enabling the Sleep State/USB Suspend implements Standby mode for CCD devices, see par. 4.5.3. When using USB devices, this mode allows the device to manage Selective Suspend conditions generated by the Host Operating System in which optimizing low power consumption (ex. Windows Stand-by). It is possible to exit the Suspend mode either from the Host (ex. moving the mouse during Stand-by) or through the barcode reader. The latter, called Remote Wakeup, makes the device wake up the Host restoring the communication. Remote Wakeup is possible either by pressing the button/trigger or by putting the reader into the stand (only for devices with Stand Recognition Beep). 4.5.2 Enter Sleep Timeout For readers that have the Sleep state enabled, this timeout determines when the reader will enter this state. 4.5.3 Standby (only for CCD devices) If this command is enabled, part of the CCD circuitry shuts down (Standby), in order to optimize low power consumption when not reading. When the trigger is pressed this circuitry powers up. This mode causes a minor delay before the reader is ready. 115 HHD II 4.6 READING PARAMETERS 4.6.1 Hand-Held and Stand Operation These parameter groups allow setting different reading modes for Hand-Held Operation and Stand Operation: SoftwareTrigger: the reader is set in FLASH MODE. Code reading takes place during the flash on time; Hardware Trigger: the code reading is started with a trigger press (ON); Hardware Trigger Ready: the illuminator is switched ON when the reader sees a code. It functions as a pointer aiming at the code to be read. The reading phase starts only when the trigger is pressed. In this mode the reader is automatically set to trigger active level and one read per cycle parameters. (Only for Hand-Held Operation). Automatic: the illuminator is switched ON when the reader sees a code. The reading phase starts automatically. Always ON: the illuminator/laser is always ON and the reader always ready for code reading. 4.6.2 Hardware Trigger Signal This parameter determines how the reader ON state is controlled for readers with button/trigger when Hardware Trigger is selected: trigger level: the reader goes ON when the trigger is pressed and goes OFF when it is released trigger pulse: the reader goes ON at the first trigger press and goes OFF only at a second press 4.6.3 Trigger-Off Timeout When this timeout is selected, the reader turns OFF automatically after the desired period of time. 4.6.4 Reads per Cycle In general, a reading cycle corresponds to the ON + OFF times of a device. The resulting effects of this parameter on code reading depend on other related configuration conditions. Here are the definitions of ON and OFF times. 116 REFERENCES For readers using the software trigger parameter (FLASH MODE), a reading cycle corresponds to the flash on + flash off times. Code reading takes place during the flash on time. For readers using the hardware trigger parameter, a reading cycle corresponds to a trigger press (ON) + one of the following OFF events: trigger release (for trigger active level) a second trigger press (for trigger active pulse) trigger-off timeout (see par. 4.6.3). When one read per cycle is selected, the device decodes only one code during the ON period and immediately turns the reader OFF. It is only possible to read another code when the next ON time occurs. In multiple reads per cycle, the ON period is extended so that the device can continue decoding codes until an OFF event occurs. For software trigger mode, the flash on period is immediately reset after each read and therefore extended. If another code is decoded before the reset flash on period expires, it is again reset and the effect is that the device remains ON, decoding codes until the flash on or timeout period expires. The Safety Time parameter should be used in this case to avoid unwanted multiple reading of the same code, see par. 4.6.5. 4.6.5 Safety Time Safety time prevents the device from immediately decoding the same code more than once. Same code consecutive reading can be disabled requiring the reader to be removed from the code (no decoding) for at least 400 ms, or a timeout can be set up to 9.9 seconds before the decoder will accept the same code. Reading is immediate if the code changes. For Automatic Hand-Held or Stand Operation, the Safety Time parameter is forced to no code consecutive reading (00). The safety time parameter is not applicable when reading stacked codes or when setting one read per cycle in hardware trigger operating mode, since these settings require voluntary action by the user. 4.6.6 Automatic Operation Aiming Light This parameter is valid for CCD long range devices in Automatic Hand-Held or Stand Operation and allows an aiming light to be continuously emitted in front of the reader to facilitate the positioning of the barcode to be read. 117 HHD II 4.6.7 Aiming System This parameter is valid for laser readers and provides a programmable timeout for the aiming system. If enabled, the scan line emitted from the reading window is preceded by a red spot which must illuminate the code center to get the best reading performance (see figure, ). Once the defined timeout is reached, the red spot disappears and is followed by the scan line to start the code scanning. 4.7 DECODING PARAMETERS CAUTION 4.7.1 These parameters are intended to enhance the decoding capability of the reader for particular applications. Used incorrectly, they can degrade the reading performance or increase the possibility of a decoding error. Ink-Spread The ink-spread parameter allows the decoding of codes which are not perfectly printed because the page texture tends to absorb the ink. 4.7.2 Overflow Control The overflow control parameter can be disabled when decoding codes printed on small surfaces, which don’t allow the use of an overflow space. This command does not effect code families 2/5, Code 128 and Code 93. 4.7.3 Interdigit Control The interdigit control parameter verifies the interdigit spacing for code families Code 39 and Codabar. 118 REFERENCES 4.8 CONFIGURATION EDITING COMMANDS The following commands carry out their specific function and then exit the configuration environment. Command Description Ì$+$*oÎ Restore system default configuration (see the relative Quick Reference Manual for default settings) Ì$+$!KÎ Transmit the Software release. This command is not effective with the Pen emulation interface. Ì$+$&_Î Transmit the device configuration in ASCII format. This command is not effective with the Pen emulation interface. 119 HHD II 4.9 CONFIGURATION COPY COMMAND Procedure: Connect the master (correctly configured reader) and the slave (reader to be configured) together through two RS232 serial interface cables and external power supply. Accessory cables and power supply are available from your Datalogic distributor to provide this connection. RS232 Cables: CAB363 & CAB364 or CAB320 & CAB328 Power Supply: PG5 Using the slave device, read the Restore Default barcode and then the RS232 interface barcode from par. 2.1.2 of this manual or from the Quick Reference Manual. With the master device, read the Configuration Copy barcode below. Copy Configuration Ì$+ZZ0$-*Î The configuration will be copied from the master to the slave device. The slave device signals the end of the procedure with a series of beeps. Note: The master device can be configured for any interface. 120 REFERENCES 4.10 DEFAULT PARAMETERS FOR POS SYSTEMS The default values for the RS232 and Data Format parameters for POS systems are listed in the following table: RS232 Group Baud Rate Parity Data Bits Stop Bits Handshaking ACK/NACK Protocol FIFO Inter-Character Delay RX Timeout Serial Trigger Lock Data Format Group Code Identifier Header Terminator Field Adjustment Code Length TX Character Replacement NIXDORF Mode A FUJITSU ICL Mode 9600 Odd 8 1 Hardware (RTS/CTS) Disabled Disabled Disabled 9.9 sec Disabled 9600 None 8 1 None Disabled Enabled Disabled 2 sec Disabled 9600 Even 8 1 RTS always on Disabled Enabled Disabled 9.9 sec Disabled Custom No Header CR Disabled Not Transmitted Disabled Custom Custom No Header No Header CR CR Disabled Disabled Not Transmitted Not Transmitted Disabled Disabled The table below lists all the Code Identifiers available for POS systems: CODE UPC-A UPC-E EAN-8 EAN-13 Code 39 Codabar Code 128 Interleaved 2 of 5 Code 93 Industrial 2 of 5 UCC/EAN 128 MSI/Plessey Code 11 NIXDORF Mode A A0 C0 B A M N K I L H P O None FUJITSU A E FF F None None None None None None None None None ICL Mode A E FF F C [code length] N [code length] L [code length] I [code length] None H [code length] L [code length] None None 121 HHD II 4.11 FIRMWARE UPGRADES Device firmware upgrades can be performed using the DL Sm@rtSet external Downloader utility tool from your PC either through RS232 or USB communications. The procedure for downloading is described in the DL Sm@rtSet User's Manual and in the Help window. A special case occurs when using USB communications to upgrade devices without button/trigger. Procedure: For devices WITHOUT button/trigger Launch the Downloader tool from the DL Sm@rtSet folder on your PC. Connect the device to the PC via USB interface. Read the code given below to emulate the trigger press: Trigger Press Ì#+UpgradexÎ The device will automatically be reset. 122 Proceed with the firmware upgrade (see the DL Sm@rtSet User's Manual for details). HOST CONFIGURATION STRINGS A HOST CONFIGURATION STRINGS In this section we provide a description of how to modify the device configuration using serial strings sent from the Host. This method requires either the RS232 or USB-COM interface. The device configuration can be changed by receiving commands from the Host through the serial interface. When this method is used, the programming sequence format is the following: $+ Command $- CR Carriage return character (0D Hex.) Exit and Save configuration Character sequence in following tables Enter configuration environment Example: Multiple command programming sequence: $+ BG1 BH0 AC410132 $- CR Carriage return character (0D Hex.) Exit and save new configuration Matrix 2/5 3 bars: no check digit, variable length code from 1 to 32 characters Beeper tone 1 Beeper low intensity Enter configuration environment Each configuration parameter setting removes the condition previously active for that parameter. NOTE The device buffer can contain about 400 characters. If your programming string goes over this value, you must split it into separate groups and send each group after a delay of at least 3 seconds to give the reader time to empty the buffer and interpret the commands. 123 HHD II SERIAL CONFIGURATION STRINGS ENTER/EXIT CONFIGURATION COMMANDS DESCRIPTION Enter Configuration Exit and Save Configuration Restore Default Transmit Software Release (not for PEN emulation) Transmit Configuration (not for PEN emulation) STRING $+ $$+$* $+$! $+$& INTERFACE SELECTION DESCRIPTION USB USB-KBD USB-KBD-ALT-MODE USB-KBD-APPLE USB-COM USB-IBM-Table Top USB-IBM-Hand Held RS232 Standard ICL Mode Fujitsu Nixdorf Mode A WEDGE for IBM AT for IBM Terminals: 31xx, 32xx, 34xx, 37xx; make-break keyboard for IBM Terminals: 31xx, 32xx, 34xx, 37xx; make-only keyboard Keyboard Type for IBM Terminals typewriter 31xx, 32xx, 34xx, 37xx advanced for IBM XT for IBM Terminal 3153 for IBM PC Notebook for IBM SURE1 for IBM AT - ALT mode for IBM PC Notebook - ALT mode for Wyse Terminal - ANSI Keyboard for Wyse Terminal - PC Keyboard for Wyse Terminal - ASCII Keyboard for Wyse Terminal - VT220 style Keyboard for Digital Terminals VT2xx/3xx/4xx for Apple ADB Bus PEN EMULATION IBM 46xx 4501 Protocol 1520 Protocol STRING UA03 UA04 UA05 UA02 UA00 UA01 CP0 CM0 CM1 CM2EC0 CP500 CP501 CP502 FK0 FK1 CP503 CP504 CP505 CP506 CP507 CP508 CP509 CP510 CP511 CP514 CP512 CP513 CP6 CP800 CP801 124 HOST CONFIGURATION STRINGS USB DESCRIPTION USB-COM Handshaking ACK/NACK Protocol FIFO Inter-character delay (ms) RX Timeout (100 ms) Serial Trigger Lock USB-KBD Keyboard nationality (not for USB-KBD-ALT-MODE) FIFO Delays Control Character Emulation STRING disable RTS/CTS XON/XOFF RTS always ON disable enable disable enable disable enable CE0 CE1 CE2 CE3 ER0 ER1 EC0 EC1 CK00 - CK99 CL00 - CL99 CR0 CR1ab Belgian English French German Italian Spanish Swedish USA Japanese disable enable Inter-Character (ms) Inter-Code (s) CTRL +Shift + Key Ctrl + Key FJ7 FJ4 FJ2 FJ3 FJ1 FJ6 FJ5 FJ0 FJ8 EC0 EC1 CK00 - CK99 FG00 - FG99 FO0 FO1 a = Hex value of the ASCII character from 00 to FE enabling the device trigger; b = Hex value of the ASCII character from 00 to FE disabling the device trigger; 125 HHD II RS232 DESCRIPTION Baud rate 300 600 1200 2400 4800 9600 19200 38400 Parity none even odd Data bits 7 8 9 Stop bits 1 2 Handshaking disable RTS/CTS XON/XOFF RTS always ON ACK/NACK Protocol disable enable FIFO disable enable Inter-character delay (ms) RX Timeout (100 ms) Serial Trigger Lock disable enable a = Hex value of the ASCII character from 00 to FE enabling the device trigger; b = Hex value of the ASCII character from 00 to FE disabling the device trigger; 126 STRING CD1 CD2 CD3 CD4 CD5 CD6 CD7 CD8 CC0 CC1 CC2 CA0 CA1 CA2 CB0 CB1 CE0 CE1 CE2 CE3 ER0 ER1 EC0 EC1 CK00 - CK99 CL00 - CL99 CR0 CR1ab HOST CONFIGURATION STRINGS WEDGE DESCRIPTION Keyboard nationality Caps Lock Caps Lock Auto-Recognition (IBM AT compatible only) Num Lock Delays Control Character Emulation Belgian English French German Italian Spanish Swedish USA Japanese (IBM AT compatible only) caps Lock ON caps Lock OFF disable enable Toggle Num Lock Num Lock Unchanged Inter-Character (ms) Inter-Code (s) CTRL +Shift + Key Ctrl + Key STRING FJ7 FJ4 FJ2 FJ3 FJ1 FJ6 FJ5 FJ0 FJ8 FE1 FE0 FP0 FP1 FL1 FL0 CK00 - CK99 FG00 - FG99 FO0 FO1 PEN DESCRIPTION Operating mode Minimum output pulse Conversion to Code 39 Output level Idle level Overflow Inter-Block Delay (100 ms) interpret (does not require $+ or $-) transparent (does not require $+ or $-) 200s 400s 600s 800s 1 ms 1.2 ms disable conversion to Code 39 enable conversion to Code 39 normal inverted normal inverted narrow overflow medium overflow wide overflow STRING $] $[ DG0 DG1 DG2 DG3 DG4 DG5 DA0 DA1 DD0 DD1 DE0 DE1 DH0 DH1 DH2 CK00-CK99 127 HHD II IBM 46xx DESCRIPTION IBM Data Formatting Code 39 Format IBM Standard Format Mixed IBM Standard + Code 39 Format STRING GD0 GD1 GD2 DATA FORMAT NOT FOR PEN EMULATION INTERFACES DESCRIPTION Code Identifier disable Datalogic standard AIM standard Custom Custom Code Identifier Headers Terminators no header one character two characters three characters four characters five characters six characters seven characters eight characters no terminator one character two characters three characters four characters five characters six characters seven characters eight characters STRING EB0 EB1 EB2 EB3 EHabc EA00 EA01x EA02xx EA03xxx EA04xxxx EA05xxxxx EA06xxxxxx EA07xxxxxxx EA08xxxxxxxx EA10 EA11x EA12xx EA13xxx EA14xxxx EA15xxxxx EA16xxxxxx EA17xxxxxxx EA18xxxxxxxx a = ASCII character. b, c, x = HEX values representing an ASCII character. a = ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 43. b = Hex value of the first Custom Code Identifier character from 00 to FE; FF = disable Code Identifier c = Hex value of the second Custom Code Identifier character from 00 to FE; FF = disable second character of Custom Code Identifier x = Hex value from 00 to FE 128 HOST CONFIGURATION STRINGS DATA FORMAT (continued) NOT FOR PEN EMULATION INTERFACES DESCRIPTION Code Length Tx not transmitted transmitted transmitted in 4-digit format disabled right addition left addition right deletion left deletion Field Adjustment Field Adjustment Character Character Replacement disable character replacement first character replacement second character replacement third character replacement STRING EE0 EE1 EE2 EF0 EFa0d EFa1d EFa2d EFa3d EGe EO0 EO1afg EO2afg EO3afg a = ASCII character. d = a number from the Hex/Numeric Table. e, f, g = HEX values representing an ASCII character. a = ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 43. d = a number in the range 01 – 32 from the Hex/Numeric Table e = Hex value from 00 to FE f = Hex value of the character to be replaced from 00 to FE g= Hex value of the new character to insert from 00 to FE FF = replace with no new character (remove character) POWER SAVE DESCRIPTION Scan Rate Sleep State/USB Suspend Enter Sleep Timeout (100 ms) Standby Quarter Half Maximum disable enable enable disable STRING BT0 BT1 BT2 BQ0 BQ1 BR00-BR99 BM0 BM1 129 HHD II READING PARAMETERS DESCRIPTION Hand-Held Operation Stand Operation Hardware Trigger Signal Trigger-off Timeout (s) FLASH ON (100 ms) FLASH OFF (100 ms) Reads per Cycle Safety Time (100 ms) Beeper Intensity Beeper Tone Beeper Type Beeper Length Good Read Spot Duration Stand Recognition Beep Automatic Operation Aiming Light Aiming System 130 software trigger hardware trigger automatic always on hardware trigger ready software trigger hardware trigger automatic always on trigger active level trigger active pulse one read multiple reads beeper off low intensity medium intensity high intensity tone 1 tone 2 tone 3 tone 4 monotone bitonal long short disable short medium long disable enable disable enable disable 300 ms 500 ms 1 sec STRING BK0 BK1 BK2 BK3 BK4 BU1 BU3 BU0 BU2 BA0 BA1 BD00 - BD99 BB001 - BB099 BB101 - BB199 BC0 BC1 BE00 - BE99 BG0 BG1 BG2 BG3 BH0 BH1 BH2 BH3 BJ0 BJ1 BI0 BI1 BV0 BV1 BV2 BV3 Ba0 Ba1 Bb0 Bb1 BX0 BX1 BX2 BX3 HOST CONFIGURATION STRINGS DECODING PARAMETERS DESCRIPTION Ink-spread Overflow control Interdigit control Decoding Safety TM PuzzleSolver disable enable disable enable disable enable one read two reads three reads four reads disable enable CODE SELECTION DESCRIPTION DISABLE ALL FAMILY CODES EAN/UPC disable EAN/UPC family EAN 8/EAN 13/UPC A/UPC E without ADD ON with ADD ON with and without ADD ON EAN 8/EAN 13 without ADD ON with ADD ON 2 ONLY with ADD ON 5 ONLY with ADD ON 2 AND 5 UPC A/UPC E without ADD ON with ADD ON 2 ONLY with ADD ON 5 ONLY with ADD ON 2 AND 5 EAN 8 check digit transmission disable enable EAN 13 check digit transmission disable enable UPC A check digit transmission disable enable UPC E check digit transmission disable enable conversions UPC E to UPC A UPC E to EAN 13 UPC A to EAN 13 EAN 8 to EAN 13 STRING AX0 AX1 AW1 AW0 AV0 AV1 ED0 ED1 ED2 ED3 AU0 AU1 STRING AZ0 AA0 AA1 AA5 AA8 AA3 AAK AAL AA6 AA4 AAM AAN AA7 AAG0 AAG1 AAH0 AAH1 AAI0 AAI1 AAJ0 AAJ1 AAA AAB AAC AAD 131 HHD II CODE SELECTION (continued) DESCRIPTION ISBN Conversion codes enable ISBN enable ISSN enable ISBN and ISSN disable ISBN and ISSN Code 39 disable Code 39 family Standard no check digit control check digit control and transmission check digit control without transmission Full ASCII no check digit control check digit control and transmission check digit control without transmission CIP 39 Code 32 code length 2/5 disable Code 2/5 family Interleaved 2/5 no check digit control check digit control and transmission check digit control without transmission Normal 2/5 5 bars no check digit control check digit control and transmission check digit control without transmission Industrial 2/5 (IATA) no check digit control check digit control and transmission check digit control without transmission Matrix 2/5 3 bars no check digit control check digit control and transmission check digit control without transmission CIP/HR STRING AP1 AP2 AP3 AP0 AB0 AB11 AB12 AB13 AB21 AB22 AB23 AB3 AB4 AB*xxxx AC0 AC11xxxx AC12xxxx AC13xxxx AC21xxxx AC22xxxx AC23xxxx AC31xxxx AC32xxxx AC33xxxx AC41xxxx AC42xxxx AC43xxxx AC5 xxxx = ASCII numbers that define the code length where: First 2 digits = minimum acceptable code length. Second 2 digits = maximum acceptable code length. The minimum code length must always be less than or equal to the maximum. The maximum code lengths are 99 characters. Examples: 0132 = variable length from 1 to 32 digits in the code. 1010 = 10 digit code length only. 132 HOST CONFIGURATION STRINGS CODE SELECTION (continued) DESCRIPTION Codabar disable Codabar family Standard no start/stop character equality control nor transmission no start/stop character equality control but transmission start/stop character equality control but no transmission start/stop character equality control and transmission ABC Codabar no start/stop character equality control but transmission Codabar ABC forced concatenation code length start/stop character case in lower case transmission upper case Code 128 disable Code 128 family enable Code 128 - control without transmission of check digit enable EAN 128 - control without transmission of check digit add GS before Code disable enable ISBT 128 enable ISBT 128 code length Code 93 disable Code 93 family enable Code 93 - control without transmission of check digit MSI disable the family no check MOD10 no tx MOD10 with tx MOD11-MOD10 no tx MOD11-MOD10 with tx MOD10-MOD10 no tx MOD10-MOD10 with tx STRING AD0 AD111 AD112 AD121 AD122 AD212 AD232 AD*xxxx ADA0 ADA1 AI0 AI11 AI21 EQ0 EQ1 AI31 AILxxxx AK0 AK1 AE0 AE1 AE2 AE3 AE4 AE5 AE6 AE7 xxxx = ASCII numbers that define the code length where: First 2 digits = minimum acceptable code length. Second 2 digits = maximum acceptable code length. The minimum code length must always be less than or equal to the maximum. The maximum code lengths are 99 characters. Examples: 0132 = variable length from 1 to 32 digits in the code. 1010 = 10 digit code length only. 133 HHD II CODE SELECTION (continued) DESCRIPTION Plessey Telepen Delta IBM Code 11 Code 16K Code 49 RSS Codes 134 disable the family Standard no check Standard check - with tx Standard check - no tx Anker no check Anker check - with tx Anker check - no tx disable the family Numeric no check Numeric check - with tx Numeric check - no tx Alpha no check Alpha check - with tx Alpha check - no tx disable the family no check Type 1 check Type 2 check disable the family no check Type C with tx Type C no tx Type K with tx Type K no tx Type C and K with tx Type C and K no tx disable enable disable enable disable the family disable RSS Expanded Linear and Stacked enable RSS Expanded Linear and Stacked disable RSS Limited enable RSS Limited disable RSS 14 Linear and Stacked enable RSS 14 Linear and Stacked STRING AF0 AF11 AF12 AF13 AF21 AF22 AF23 AL0 AL11 AL12 AL13 AL21 AL22 AL23 AH0 AH1 AH2 AH3 AG0 AG1 AG21 AG22 AG31 AG32 AG41 AG42 AJ0 AJ1 AM0 AM1 AQ0 AQ10 AQ11 AQ20 AQ21 AQ30 AQ31 CODE IDENTIFIER TABLE B CODE IDENTIFIER TABLE 2/5 Interleaved ÌNOÎ 2/5 Industrial ÌPQÎ 2/5 normal 5 bars ÌOPÎ 2/5 matrix 3 bars ÌQRÎ EAN 8 ÌABÎ EAN 13 ÌBCÎ UPC A ÌCDÎ UPC E ÌDEÎ EAN 8 with 2 ADD ON ÌJKÎ EAN 8 with 5 ADD ON ÌKLÎ EAN 13 with 2 ADD ON ÌLMÎ EAN 13 with 5 ADD ON ÌMNÎ 135 HHD II UPC A with 2 ADD ON ÌFGÎ UPC A with 5 ADD ON ÌGHÎ UPC E with 2 ADD ON ÌHIÎ UPC E with 5 ADD ON ÌIJÎ Code 39 ÌVWÎ Code 39 Full ASCII ÌWXÎ CODABAR ÌRSÎ ABC CODABAR ÌSTÎ Code 128 ÌTUÎ EAN 128 ÌklÎ ISBT 128 ÌfgÎ CIP/HR ÌefÎ CIP/39 ÌYZÎ 136 CODE IDENTIFIER TABLE Code 32 ÌXYÎ Code 93 ÌUVÎ MSI ÌZ[Î Plessey Standard ÌabÎ Plessey Anker ÌopÎ Delta IBM ÌcdÎ Telepen ÌdeÎ Code 16K ÌpqÎ Code 11 ÌbcÎ Code 49 ÌqrÎ RSS Expanded Linear and Stacked ÌtuÎ RSS Limited ÌvwÎ RSS 14 Linear and Stacked ÌuvÎ 137 C HEX AND NUMERIC TABLE CHARACTER TO HEX CONVERSION TABLE char hex char hex char hex NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US SPACE ! " # $ % & ' ( ) 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ? @ A B C D E F G H I J K L M N O P Q R S T 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 U V W X Y Z [ \ ] ^ _ ` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ DEL 55 56 57 58 59 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F HEX AND NUMERIC TABLE HEX / NUMERIC TABLE CHARACTER TO HEX CONVERSION TABLE char hex char hex char hex € 80 81 82 83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9E 9F A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 ª « ¬ ® ¯ ° ± ² ³ ´ µ ¶ · ¸ ¹ º » ¼ ½ ¾ ¿ À Á Â Ã Ä Å Æ Ç È É Ê Ë Ì Í Î Ï Ð Ñ Ò Ó Ô AA AB AC AD AE AF B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF D0 D1 D2 D3 D4 Õ Ö × Ø Ù Ú Û Ü Ý Þ ß à á â ã ä å æ ç è é ê ë ì í î ï ð ñ ò ó ô õ ö ÷ ø ù ú û ü ý Reserved Reserved D5 D6 D7 D8 D9 DA DB DC DD DE DF E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC ED EE EF F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 FA FB FC FD FE FF ‚ ENTER TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 HOME END Pg UP Pg Down Ç È Å Æ ESC CTRL(Right) € œ ž Ÿ NBSP ¡ ¢ £ ¤ ¥ ¦ § ¨ © Ì01Î 0 Ì12Î 1 Ì23Î 2 Ì34Î 3 Ì45Î 4 Ì56Î 5 Ì67Î 6 Ì78Î 7 Ì89Î 8 Ì9:Î 9 ÌABÎ A ÌBCÎ B ÌCDÎ C ÌDEÎ D ÌEFÎ E ÌFGÎ F Backspace Ì$%/Î Cancels an incomplete configuration sequence HEX AND NUMERIC TABLE HEX / NUMERIC TABLE CHARACTER TO HEX CONVERSION TABLE char hex char hex char hex € 80 81 82 83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9E 9F A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 ª « ¬ ® ¯ ° ± ² ³ ´ µ ¶ · ¸ ¹ º » ¼ ½ ¾ ¿ À Á Â Ã Ä Å Æ Ç È É Ê Ë Ì Í Î Ï Ð Ñ Ò Ó Ô AA AB AC AD AE AF B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF D0 D1 D2 D3 D4 Õ Ö × Ø Ù Ú Û Ü Ý Þ ß à á â ã ä å æ ç è é ê ë ì í î ï ð ñ ò ó ô õ ö ÷ ø ù ú û ü ý Reserved Reserved D5 D6 D7 D8 D9 DA DB DC DD DE DF E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC ED EE EF F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 FA FB FC FD FE FF ‚ ENTER TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 HOME END Pg UP Pg Down Ç È Å Æ ESC CTRL(Right) € œ ž Ÿ NBSP ¡ ¢ £ ¤ ¥ ¦ § ¨ © Ì01Î 0 Ì12Î 1 Ì23Î 2 Ì34Î 3 Ì45Î 4 Ì56Î 5 Ì67Î 6 Ì78Î 7 Ì89Î 8 Ì9:Î 9 ÌABÎ A ÌBCÎ B ÌCDÎ C ÌDEÎ D ÌEFÎ E ÌFGÎ F Backspace Ì$%/Î Cancels an incomplete configuration sequence Australia Japan Datalogic Scanning Pty Ltd Telephone: [61] (2) 9870 3200 australia.scanning@datalogic.com Datalogic Scanning KK Telephone: 81 (0)3 3491 6761 japan.scanning@datalogic.com France and Benelux Latin America Datalogic Scanning Sarl Telephone: [33].01.64.86.71.00 france.scanning@datalogic.com Datalogic Scanning, Inc Telephone: (305) 591-3222 latinamerica.scanning@datalogic.com Germany Singapore Datalogic Scanning GmbH Telephone: 49 (0) 61 51/93 58-0 germany.scanning@datalogic.com Datalogic Scanning Singapore PTE LTD Telephone: (65) 6435-1311 singapore.scanning@datalogic.com India Spain and Portugal Datalogic Scanning India Telephone: 91- 22 - 64504739 india.scanning@datalogic.com Datalogic Scanning Sarl Sucursal en España Telephone: 34 91 746 28 60 spain.scanning@datalogic.com Italy United Kingdom Datalogic Scanning SpA Telephone: [39] (0) 39/62903.1 italy.scanning@datalogic.com Datalogic Scanning LTD Telephone: 44 (0) 1923 809500 uk.scanning@datalogic.com www.scanning.datalogic.com Datalogic Scanning, Inc. 959 Terry Street Eugene, OR 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 ©2009 Datalogic Scanning, Inc. 90ACC1877 (Rev. E) 4/09
Similar documents
TC1100 - OEM International AB
Keyboard Nationality................................................................................... 47 Caps Lock ...................................................................................
More information