Model GT 1175 Electrical Installation Manual **with U30
Transcription
Model GT 1175 Electrical Installation Manual **with U30
S82 W18717 Gemini Drive Muskego, Wisconsin 53150 Phone: (877) 622-2694 Fax: (888) 679-3319 www.nabcoentrances.com Technical Support: (866) 622-8325 Model GT 1175 Electrical Installation Manual **with U30 Microprocessor Controller** (with Revision D Software) HANDY TERMINAL HARNESS P/N 14-11837 INDICATORS TB2 GROUND LUG SCREW TO HEADER ON/OFF POWER SWITCH GROUND HARNESS P/N 14-11872 FUNCTION [SLIDING DOOR] 12VDC+ 12VDC-(COMMON) INTERIOR ACTIVATION HOLDING BEAM REDUCED OPENING SWITCH 6B H 62 BA ERROR AC115V ± 10% 50 / 60 Hz BLACK (HOT) WHITE (COMMON) 61 POWER・2P 20VAC 50/60Hz S1 TRANSFORMER 5 A M P MADE IN JAPAN R1 To protect against risk of fire or electric shock,use only the certified NABCO power supply. MOTOR・12P POWER DS-150NA ZN TB1 WARNING T1 GYRO TECH NOISE FILTER (24-11327) ZN R2 U30 CONTROL P/N 24-8901-30 MOTOR/OPERATOR P/N 24-11327 GYRO TECH HANDY TERMINAL・6P No. Microprocessor Controller 248901- Mode SW Usage M0 M1 MODE Open Open TWO WAY FUNCTION [SLIDING DOOR] Gnd Open ONE WAY 12VDC+ Gnd Gnd HOLD OPEN 12VDC-(Common) Open Gnd NIGHT Interior Activation Holding Beam Reduced Opening Switch CAUTION Adjustments to the door can only be made with the NABCO Handy Terminal. Do not disassemble the control box. There are no user serviceable parts inside. To maintain warranty,repairs must be made by authorized NABCO facilities. SYMBOL No. 9DC12V 1 7 2 61 3 6B 4 H 5 M0 6 M1 7 62 8 9 SQ BA 10 11 SLS N/O OUT.A 12 N/C OUT.B 13 Common OUT.C 14 OUT 15 16 7 Mode Switch (see Mode SW Usage shown left) Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) RELATED DEVICES・16P POWER SUPPLY P/N 14-11741 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 POWER SUPPLY HARNESS P/N 14-11874 120 VAC AUXILIARY 120 VAC POWER WIRES (THESE WIRES NORMALLY COILED AND TIED UP) RELATED DEVICES - 16P SYMBOL No. 9DC12V 1 1 7 2 2 61 3 3 6B 4 4 5 H 5 6 M0 6 Mode Switch (see Mode SW Usage shown left) 7 M1 7 Exterior Activation 8 62 8 Sequential Activation SQ 9 9 Breakout Detector 10 BA 10 11 Sidelite Presence Sensor SLS 11 GRAY (OUT A) Contact Output (Class2 Load only) 12 N/O OUT.A 12 30V(42.4Vpeak)max. 13 N/C OUT.B 13 VIOLET 5Amax.(0-20V), 3.2Amax.(20-30V) 14 14 Common OUT.C Auxiliary Output (Open-Collector) 15 OUT 15 16 7 16 12VDC-COMMON LABEL ON U30 CONTROL TERMINAL ON U30 MAIN HARNESS 110V 1 FAIL SECURE BLK WHT GRY VIO 6 FAIL SECURE LOCK ASSY. P.N. 22-10522-03 WIRING FOR ELECTRIC LOCK ONLY SHOWN P/N 24-11877 U30 ELECTRIC STRIKE OUTPUT SIGNAL HANDY TERMINAL: AUX OUTPUT = 0, OUTPUT TIMER = 3, ROCKER SWITCH SETTING: ONE WAY OR NIGHT MODE ON OUTPUT: 0 = ELECTRIC STRIKE OUTPUT OUTPUT TIMER 0 = (DO NOT USE) 1 = (DO NOT USE) 2 = (DO NOT USE) 3 = ELECTRIC STRIKE FUNCTION ACTIVATION SIGNAL OFF ON OUTPUT SIGNAL OFF 3 SEC OPENING OUTPUT TIMER 1.0 SEC FULL OPEN FULLY CLOSED FULLY CLOSED DN 0552 CLOSING WARNING • Turn OFF all power to the Automatic Door if a Safety System is not working. • Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a NABCO trained technician. Failure to follow these practices may result in serious consequences. • NEVER leave a Door operating without all Safety detection systems operational. Part #15-10596-30 Rev. 1/10/14 THIS PAGE IS INTENTIONALLY LEFT BLANK www.NabcoEntrances.com Rev. 1-10-14 Electrical Installation Manual U-30 Control Part #14-10596-30 Table of Contents Warning Labels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii General Safety Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv CHAPTER 1: SCOPE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Section 1a: To the Installer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Section 1b: Objective. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 CHAPTER 2: GETTING STARTED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 Section 2a: About the U30 Microprocessor Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 Section 2b: Electrical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 Section 2c: Output Power Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Section 2d: Header Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 CHAPTER 3: CONNECT INCOMING 120 VAC WIRES . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9 CHAPTER 4: IDENTIFY OPERATING WIRES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10 Section 4a: 16 Pin Controller Terminal Block Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-10 Section 4b: Sensor Wire Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11 Section 4c: Rocker Switch Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12 CHAPTER 5: WIRING DIAGRAMS (SURFACE APPLIED SLIDERS) . . . . . . . . . . . . . . . . 5-14 Section 5a: (2) Acusensors and (1) Holding Beam. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-14 Section 5b: (2) Optex I-One and (1) Holding Beam. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15 Section 5c: (2) Acusensors, (1) Holding Beam and (1) Breakout Beam Control. . . . . . . . . . . . . . . . 5-16 Section 5d: (2) Optex I-One, (1) Holding Beam and (1) Breakout Beam Control . . . . . . . . . . . . . . . 5-17 Section 5e: (2) Wizard G3, and (1) Holding Beam. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18 Section 5f: (2) Wizard G3, (1) Holding Beam and (1) Breakout Control . . . . . . . . . . . . . . . . . . . . . . 5-19 i Electrical Installation Manual U-30 Control Part #14-10596-30 www.NabcoEntrances.com Rev. 1-10-14 CHAPTER 6: INFRARED BEAM WIRING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-20 Section 6a: Wiring (1) Holding Beam. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-20 Section 6b: Wiring (2) Holding Beams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-21 Section 6c: Wiring Holding Beam for Breakout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-22 CHAPTER 7: ELECTRIC LOCK WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-23 Section 7a: Adjust the Strike. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-23 Section 7b: U30 with Fail Safe Electric Lock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-24 Section 7c: U30 with Fail Secure Electric Lock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-25 Section 7d: U30 with Magnetic Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-26 CHAPTER 8: CUSTOM WIRING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-27 Section 8a: U30 Configured for Remote Control of Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-27 Section 8b: Sidelite Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-28 Section 8c: U30 Using Card Readers or other Secure Activation Devices. . . . . . . . . . . . . . . . . . . . . 8-29 CHAPTER 9: TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-30 CHAPTER 10: RETURN POLICY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-31 Section 10a: How to Print and Fill out a Return Material Tag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-31 ii www.NabcoEntrances.com Electrical Installation Manual U-30 Control Rev. 1-10-14 Part #15-10596-30 WARNING LABELS Warning labels are universal and used to alert an individual of potential harm to one’s self or to others. The following warning labels are listed in a hierarchy order that defines the most potential danger first, and the least potential danger last. Please refer to this page in the event that a warning label is displayed within this manual and further definition needs to be explained. DANGER Indicates potentially dangerous situations. Danger is used when there is a hazardous situation where there is a high probability of severe injury or death. It should not be considered for property damage unless personal injury risk is present. WARNING Indicates a hazardous situation which has some probability of severe injury. It should not be considered for property damage unless personal injury risk is present. CAUTION Indicates a hazardous situation which may result in a minor injury. Caution should not be used when there is a possibility of serious injury. Caution should not be considered for property damage accidents unless a personal injury risk is present. Notice: Indicates a statement of company policy as the message relates to the personal safety or protection of property. Notice should not be used when there is a hazardous situation or personal risk. Note: Indicates important information that provides further instruction. iii Electrical Installation Manual U-30 Control www.NabcoEntrances.com Part #15-10596-30 Rev. 1-10-14 GENERAL SAFETY RECOMMENDATIONS WARNING Do not install, operate or service this product unless you have read and understand the General Safety Recommendations, Warning Labels, contained in this manual. Failure to do so may result in bodily injury, or property damage. WARNING Read, study and understand the installation and operating instructions contained in, or referenced in this manual before operating. If you do not understand the instruction, ask a qualified technician. Failure to do so may result in bodily injury, or property damage and will nullify all warranties. Notice: Disconnect all power to the junction box prior to making any electrical connections. Failure to do so may result in seriouc personal or fatal injury. When uncertain whether power supply is disconnected, always verify using a voltmeter. DANGER iv This manual and the owner’s manual must be given to and retained by the purchasing facility or end user. Notice: Wiring must meet all local, state, federal or other governing agency codes. Notice: All electrical troublshooting or service must be performed by qualified electrical technicians and must comply with all applicable governing agency codes. DANGER Do not place finger or uninsulated tools inside the electrical controller. Touching wires or other parts inside the enclosure may cause electrical shock, serious injury or death. CAUTION The Ground wire from the Magnum IV Control 120 VAC Harness, and the Incoming 120 VAC Ground wire must be connected to the Ground screw located within the Swing door Header. CAUTION If the door appears broken or does not seem to work correctly, it should be immediately removed from service until repairs can be carried out or a qualified service technician is contacted for corrective action. Note: All Adjustments must be made with a small screwdriver. Do Not use a pencil. Note: Do Not take shortcuts. www.NabcoEntrances.com Rev. 1-10-14 Electrical Installation Manual U-30 Control Part #15-10596-30 CHAPTER 1: SCOPE Section 1a: To the Installer The purpose of this manual is to familiarize the installer and purchaser with the proper installation and operation of this system. It is essential that this equipment be properly installed and operational before the door is used by the public. It is the installer’s responsibility to inspect the operation of the entrance system to be sure it complies with any applicable standards. Instruct the building owners and operator on the essentials of the operation of the U30 Microprocessor Controller. The owner should follow these instructions to determine whether the door is operating properly and should immediately call for service if there is any malfunction. All installation changes and adjustments must be made by qualified, NABCO trained technicians. Section 1b: Objective The U30 Microprocessor Controller is designed to be installed within the Header of the GT-1175 Slide Door systems. This manual offers step by step instructions. Scope 1-5 Electrical Installation Manual U-30 Control www.NabcoEntrances.com Part #15-10596-30 Rev. 1-10-14 CHAPTER 2: GETTING STARTED Section 2a: About the U30 Microprocessor Control The U30 Microprocessor Control is utilized on all GT-1175 Slide Door systems to control numerous operating characteristics that include (but not limited to): speed, recycling sensitivity and reduced opening width. Note: The U30 Microprocessor Control will need to be programmed after installation is complete. The U30 Microprocessor Control is also utilized to output power to accessories and/or auxiliary equipment such as: ►►Sensors ►►Modules There are times when the U30 Microprocessor Control is not utilized to output power because some accessories and/or auxiliary equipment are shipped with it’s own dedicated power supply. Section 2b: Electrical Specifications All Wiring Diagrams included within this manual, reflect typical primary and secondary circuits that are installed at the NABCO Factory. The low voltage Reed Switch (12 VDC) and Sensor(s) are also installed complete with connector housings at the NABCO Factory. Note: NABCO factory utilizes Underwriters Laboratories (UL) recognized component wire, terminals and connector housings to manufacture GT-1175 Slide Door systems. Table 2-1 Sensors Sensor Acusensor 3 Wizard G3 Optex i-one Part Number 14-8902-3 14-13316 14-13036 Table 2-2 Modules Module Optex Beam CP/RX Radio Control Receiver 2-6 Function Infrared Power Source Infrared + Microwave Infrared Part Number 14-9710-01 24-11467 12 to 24 AC or DC 12 to 24 VAC or VDC 12 to 24 VAC or 12 to 30 VDC Function Beam & Control Power Source 12 to 24 AC or DC RF Signal Transmission 12 to 24 AC or DC Current Consumption 100mA 250mA (ea.unit) at 12VDC 130mA Current Consumption 160mA 50mA (ea.unit) at 12VDC Getting Started www.NabcoEntrances.com Electrical Installation Manual U-30 Control Rev. 1-10-14 Part #15-10596-30 Section 2c: Output Power Guidelines TOTAL current draw from the U30 Microprocessor Control must not exceed 350 mA (0.35 amps) when outputting power to: ►►Sensors ►►Modules ►►Accessories ►►Auxiliary Equipment CAUTION If TOTAL current draw exceeds 350mA (0.35 amps) the installer must utilize an auxiliary power supply such as a 24 VAC Transformer (P/N 14-2101). The U30 Microprocessor Control and/or the NABCO Power Supply Module Must Not be used to output power to Magnetic Locks or Electric Strikes. To determine if an auxiliary power supply must be used, add together each current draw for each device. Please refer to the formula shown below: Example: A GT-1175 Slide Door is to be fitted with the following devices: 2 x Optex i-one Sensors @ 130 mA = 260 mA 1 x Optex Beam Module @ 160 mA = 160 mA Total = 420 mA 420mA exceeds 350mA. An Auxiliary Power Supply must be used to supply power to the Optex Beam Module. Section 2d: Header Layout Nabco GT-1175 Sliding Door systems come in many sizes and configurations. Because of this components within the Header are layed out in (1 of 3) different configurations to ensure proper operation of the Drive Belt. Please see configuration details listed below: ►►Operator/Control/Power • Header Width is not wide. Operator needs to be installed to the left of the U30 Microprocessor Control. Please see Figure 2-1. • Header Width is wide, but Operator still needs to be installed between the Power Supply and the U30 Microprocessor Control. Please see Figure 2-2. • Header Width is wider. Operator can be installed to the right of the Power Supply and the U30 Microprocessor Control. Please see Figure 2-3. ►►Power/Operator/Control ►►Power/Control/Operator Note: Note: Getting Started The Power Supply must never be installed between the U30 Microprocessor Control and the Operator. No matter the location, electrical wiring for all (3) components stays the same. 2-7 Electrical Installation Manual U-30 Control www.NabcoEntrances.com Part #15-10596-30 Rev. 1-10-14 U30 Microprocessor Controller Header INDICATORS POWER・2P 20VAC 50/60H 432 765 Operator To maintain warranty,repairs must e made y authori ed NABCO facilities. No. HANDY TERMINAL・6P Mode Switch (see Mode SW Usage shown left) Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) N/O N/C Common SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT.A OUT.B OUT.C OUT 7 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 NR NR 2 1 TB1 TB2 S1 Power Supply Figure 2-1 Header Layout “OCP” with or without Electric Lock Operator A RNING T1 TRANSFORMER LABEL M< To protect against risk o ire or electric shock,use only the certi ied NABCO power supply. MOTOR・12P PO E R 61 GYRO TECH DS-150NA INDICATORS R2 1 >PO NOISE FILTER ZN ZNR O 5 A M P TB1 (24-11327) TB2 6B PO E R・2P 20VAC 50/60H 98 I 432 11 10 1 12 Mode S Usag e MODE M1 Open T O AY Open ONE AY Gnd HOLD OPEN Gnd NIGHT CAUTION BA ERROR 7 0 M0 Open Gnd Gnd Open GYRO TECH H 62 MADE IN JAPAN S1 Ad ustments to the door can only e mad e with the NABCO Handy Terminal. Do not disassem le the control ox. There are no user servicea le parts inside. To maintain warranty,repairs must e made y authori ed NABCO acilities. 765 Power Supply HANDY TERMINAL・6P No. Microprocessor Controller 248901FUNCTION [SLIDING DOOR] 12VDC 12VDC-(Common) Interior Activation Holding Beam Reduced Opening Switch Mode Switch (see Mode S Usage shown le t) Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V ) Auxiliary Output (Open-Collector) 12VDC-(Common) N/O N/C Common SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT.A OUT.B OUT.C OUT 7 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 RELATED DEVICES・16P Header DN 0536 T1 NOISE FILTER Microprocessor Controller 248901FUNCTION [SLIDING DOOR] 12VDC+ 12VDC-(Common) Interior Activation Holding Beam Reduced Opening Switch TRANSFORMER LABEL M< 98 DN 0537 Mode SW Usage MODE M1 Open TWO WAY Open ONE WAY Gnd HOLD OPEN Gnd NIGHT CAUTION Ad ustments to the door can only e mad e with the NABCO Handy Terminal. Do not disassem le the control ox. There are no user servicea le parts inside. RELATED DEVICES・16P >PO 10 7 0 M0 Open Gnd Gnd Open GYRO TECH H 62 I 11 O 61 6B BA ERROR 1 12 5 A M P WARNING To protect against risk of fire or electric shock,use only the certified NABCO power supply. MOTOR・12P POWER GYRO TECH DS-150NA (24-11327) MADE IN JAPAN U30 Microprocessor Controller Figure 2-2 Header Layout “POC” with or without Electric Lock Header Operator M0 Open Gnd Gnd Open Mode SW Usage MODE M1 Open TWO WAY Open ONE WAY Gnd HOLD OPEN Gnd NIGHT CAUTION Adjustments to the door can only be made with the NABCO Handy Terminal. Do not disassemble the control box. There are no user serviceable parts inside. To maintain warranty,repairs must be made by authorized NABCO facilities. No. HANDY TERMINAL・6P Microprocessor Controller 248901FUNCTION [SLIDING DOOR] 12VDC+ 12VDC-(Common) Interior Activation Holding Beam Reduced Opening Switch Mode Switch (see Mode SW Usage shown left) Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Senso r Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V ) Auxiliary Output (Open-Collector) 12VDC-(Common) N/O N/C Common SYMBOL No. 9DC12V 1 7 2 61 3 6B 4 5 H M0 6 M1 7 8 62 SQ 9 10 BA SLS 11 OUT.A 12 OUT.B 13 OUT.C 14 15 OUT 16 7 GYRO TECH DS-150NA (24-11327) MADE IN APAN 1 12 432 NABCO GYRO TECH RELATED DEVICES・16P INDICATORS H 62 O 5 A M P I POWER・2P 20VAC 50/60Hz TRANSFORMER LABEL 61 6B BA ERROR 11 7 0 765 To protect against risk of fire or electric shock,use only the certified NABCO power supply. MOTOR・12P POWER TB2 98 Power Supply 2-8 WARNING T1 10 DN 0535 S1 M R2 1 >PO NOISE FILTER ZN ZNR TB1 U30 Microprocessor Controller Figure 2-3 Header Layout “PCO” with or without Electric Lock Getting Started www.NabcoEntrances.com Electrical Installation Manual U-30 Control Rev. 1-10-14 Part #15-10596-30 CHAPTER 3: CONNECT INCOMING 120 VAC WIRES Disconnect power to the junction box prior to making any electrical connections. Failure to do so may result in serious personal or fatal injury. When uncertain whether power supply is disconnected, always verify using a voltmeter. DANGER Notice: Wiring must meet all local, state, federal or other governing agency codes. 1. Ensure all power is disconnected at the Junction box. 2. Ensure all power to the GT-1175 Slide Door is Off. 3. Inspect the location and grade of all Incoming 120 VAC power cables. 4. Insert all Incoming 120 VAC, single phase, 5 amp (minimum) power wires into the pre drilled Electric Service Access Hole located at the left or right side of Jamb Tube and Header End Cap. a. It is recommended for the Installer to house all Incoming 120 VAC wires within an Electrical Conduit. Keep all Incoming 120 VAC wiring separate from low voltage wiring within Header. CAUTION Do Not route 120 VAC wires near the U30 Microprocessor Controller and Operater. CAUTION 5. Please see Figure 3-1, to follow steps on how to connect Incoming 120 VAC wires to Power Supply. 6. Go to the TB1 Port located on the Left side of the Power Supply Module. 7. Insert the Incoming 120 VAC Black (HOT) wire into the Circuit marked “L”. 8. Insert the Incoming 120 VAC White (Neutral) wire into the Circuit marked “N”. 9. Insert Green (Grounding) wire into the Circuit marked “PE”. Read and understand the “U30 Controller Setup and Programming Manual” P/N 15-9000 before attempting to power-up the GT-1175 Slide Door. Failure to do so may result in damage to the Slide door and/or injury to the installer and will nullify all warranties. DANGER Black Wire (Hot) NABCO N NA DS-1500 D24-113270 GYRO TECH 6B INDICATORS LOAD H 32 ERROR 11 1 12 7 0 M0 Open Gn d Gn d Open ! Adjustments to the door can only be made with the NABCO Handy Terminal. Do not disassemble the control box. There are no user serviceable parts inside. ! Mode SW Usage MODE M1 Open TWO WAY Open ONE WAY Gn d HOLD OPEN Gn d NIGH T ! CAUTION 62 BA MADE IN JAPAN 4 S1 GYRO TECH Nabtesco Corporation POWER SUPPLY ASSEMBLY P/N 9418800100 NABCO ENTRANCES, INC. 14-11741 ! WARNING To protect against risk of Fire or electric shock,use only the ! NABCO 61 7 6 5 PRESS TO RESET MOTOR 12P POWER 8 Grounding Wire -CIRCUIT-BREAKERRED INDICATES POWER IS OFF O 10 9 (Common) TB1 BC NABCO POWER 2P 20VAC 50/60Hz PE White Wire TB2 To maintain warranty,repairs must be made by authorized NABCO facilities. No. HANDY TERMINAL 6P Microprocessor Controller 248901FUNCTION (SLIDING DOOR) 12VDC + 12VDC-(Common) Interior n Holding Beam Reduced Opening Switch Exterior A Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) N/O N/C Common SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT. A OUT. B OUT. C OU T 7 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 RELATED DEVICES・16P T1 >PO M< L NOISE FILTER ON/OFF Power Switch P/N 14-11872 Connect Incoming 120 VAC Wires DN 0538 Figure 3-1 Connect Incoming 120 VAC Wires to Power Supply 3-9 Electrical Installation Manual U-30 Control www.NabcoEntrances.com Part #15-10596-30 Rev. 1-10-14 CHAPTER 4: IDENTIFY OPERATING WIRES Section 4a: 16 Pin Controller Terminal Block Assignments Note: All wires are identified by color. All references to signals are made in connection with Common (Red). Note: Use a flat-blade screwdriver to remove the Terminal Connector from the U30 Microprocessor Controller. Ensure that all wires are matched to each appropriate Terminal. Each Terminal is numbered with corresponding information on the Face Plate of the U30 Microprocessor Controller. Note: Common Terminal indicates terminal can be Output or Input. * Color1/Color2 denotes a base wiring Color 1 with a stripe Color 2. For example: Black/Red indicates a Black wire with a Red Stripe. Terminal # Symbol Color 1 9DC12V Brown 2 7 Red 4-10 Description XX Output terminal • Sensor power source. • Output is 12VDC with a maximum capacity of 350mA (.35 amp). XX Common terminal • Provides common ground for the 12 VDC power and signal source. 3 61 Black 4 6B White 5 H Green 6 M0 Orange 7 M1 8 62 Orange/ XX Input terminal White* • Mode Switch Two (SW2). • Used to acheive special functions. Please refer to “Switch Settings” section within this chapter. 9 SQ Black/ Red* Yellow XX Input terminal • Interior Activation signal. • Opens the door in two-way and one-way modes only. XX Input terminal • Holding Beam signal. • Opens or re-opens a Sliding door. XX Input terminal • Reduced Opening Switch signal. • Reduces Slide door opening when switched to Red (7). XX Input terminal • Mode Switch One (SW1). • Used to acheive special functions. Please refer to “Switch Settings” section within this chapter. XX Input terminal • Exterior Activation signal. • Opens the door in two-way mode only. XX Input terminal • Sequential Activation signal. • Allows a sequence of signals to open and close Slide door. Identify Operating Wires www.NabcoEntrances.com Electrical Installation Manual U-30 Control Rev. 1-10-14 Part #15-10596-30 Terminal # Symbol Color 10 BA Blue 11 SLS 12 OUT A Green/ White* 13 OUT B 15 OUT 14 OUT C 16 7 Gray Gray Violet Description XX Input terminal • Breakout Detector signal. • Connected to Red (7) during normal operation. • Disconnected from Red (7) during ‘stop door’ operation. Will happen if: • Switch is turned OFF • Slide door is panicked open XX Input terminal • Sidelite Presence Sensor. • At fully closed position, input will prevent Slide door from opening. XX Auxiliary Output terminal • Connected to Normally Open contact on an internal relay. • Referred to as ‘Auxiliary Relay Output” throughout manual. • Used as a Switch to: • Sequence an Electric Strike. • Control other Slide doors in an air lock situation. • Signal a remote computer on the Slide door operation. XX Auxiliary Output terminal • Connected to Normally Closed contact on an internal relay. XX Auxiliary Output terminal • Common for output wire “OUT A” or ‘OUT B” Brown/ XX Auxiliary Output 2 terminal Yellow* • Connected to an Internal Transistor with Open Collector in the U30 Microprocessor Controller. • Installer must provide wire for this terminal (not normally utilized). Red XX Common terminal • Provides common ground for the 12 VDC power and signal source. Section 4b: Sensor Wire Connections * Color1/Color2 denotes a base wiring Color 1 with a stripe Color 2. For example: Black/Red indicates a Black wire with a Red Stripe. ** Denotes wiring that has been crimped together at NABCO factory. Table 4-1 Acusensor U30 Harness Red Black *Black/Red Brown Common Signal, Interior Signal Exterior Identify Operating Wires +12 VDC Extension Harness Acusensor Harness Red **White and Red Gray Black Yellow Green 4-11 Electrical Installation Manual U-30 Control www.NabcoEntrances.com Part #15-10596-30 Rev. 1-10-14 Table 4-2 Optex i-one U30 Harness Red Black *Black/Red Brown *Black/Red Brown Red **Gray and White Gray Gray Interior Signal Yellow Exterior Signal +12 VDC U30 Harness Black Optex i-one Harness Common Table 4-3 Wizard Red Extension Harness Yellow Extension Harness Wizard Harness Red **Red and White and Brown Gray Black Common Interior Signal Yellow Exterior Signal +12 VDC Green and Blue Section 4c: Rocker Switch Settings OFF = Not switched to COMMON Rocker Switch Mode Key Switch Mode Night Night OFF ON - XX Sensors on Terminal (3) and (8) can not open the door while door is closed. XX Sensors on Terminal (3) and (8) will provide threshold safety when door is in any position other than closed. XX Electric Lock remains locked unless an activation signal is given from a device (such as card reader, key switch, wall plate, etc.): connected in one of two ways: 1. Between Common and MO (7) a. This only works when door is in “Night” mode 2. Between Common and SLS (11) a. This only works if the SLS is programmed for activation devices. Note: Consult the U30 Programming Manual for details; (P/N 15-9000-30). Hold Open H.O. ON ON - Two Way Auto OFF OFF - XX No activation needed when “Hold Open” is selected. Slide door is held open. XX Electric Lock is always unlocked. 4-12 Wire Wire Wire M0 M1 H ON = Switched to COMMON (RED 7) Description XX Sensors on Terminal (3) and (8) can both open the door. XX Electric Lock is always unlocked. Identify Operating Wires www.NabcoEntrances.com Electrical Installation Manual U-30 Control Rev. 1-10-14 Part #15-10596-30 Rocker Switch Mode Key Switch Mode One Way Exit ON OFF - Full Open Full - - - - OFF Reduced Open Reduced Identify Operating Wires Wire Wire Wire M0 M1 H ON Description XX Sensor on Terminal (3) can open the door. • Sensor is normally Interior and used to activate door for one-way traffic. XX Sensor on Terminal (8) can not open the door from the closed position. • Sensor is normally Exterior and used to provide threshold safety only. • Electric Lock remains locked unless an activation occurs from the interior sensor or by a device (such as a card reader, key switch, wall plate, etc.) that is connected in one of two ways: 1. Between Common and M1 (6) a. This only works when door is in “One Way” or “Exit” mode. 2. Between Common and SLS (11) a. This only works if the SLS is programmed for activation devices. Note: Consult the U30 Programming Manual for details; (P/N 15-9000-30). XX Upon activation or in Hold Open mode, Slide door will open to the full position. XX Upon activation, Slide door will open to the Reduced Open position. 4-13 Common N/O N/C LOAD TWO WAY HOLD OPEN ONE WAY NIGHT OFF ON BACK SIDE OF ROCKER SWITCH SHOWN ROCKER SWITCH FOR U30 PN 14-11875 KEY SWITCH FOR U30 PN 14-11876 FULL OPEN ORANGE RED ORG/WHT RED GREEN ORG/WHT RED ORANGE WHITE WHITE WHITE U30 TERMINAL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 MAGNETIC POWER DOWN SWITCH P/N 22-9222 WHITE BLUE BLUE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 NABCO WHITE RED RED ORG/WHT BLUE GREEN ORANGE BLUE BROWN RED BLACK WHITE GREEN ORANGE ORG/WHT BLK/RED YELLOW BLUE GRN/WHT MADE IN JAPAN Nabtesco Corporation DS-1500 D24-113270 GYRO TECH NABCO NA BC O 1 1211 7 0 ! ! ! ! WARNING M0 Open Gn d Gn d Open Mode SW Usage MODE M1 Open TWO WAY Open ONE WAY Gn d HOLD OPEN NIGH T Gn d To protect against risk of Fire or electric shock,use only the cerfied NABCO power supply. To maintain warranty,repairs must be made by authorized NABCO facilities. Do not disassemble the control box. There are no user serviceable parts inside. Adjustments to the door can only be made with the NABCO Handy Terminal. ! CAUTION GYRO TECH NABCO Mode Switch (see Mode SW Usage shown le) Exterio r Acvaon Sequenal Acvaon Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED U30 TERMINAL P/N 24-11877 DN 0539 OPTEX HOLDING BEAM CONTROLLER PT. NO. PN 14-9710-03 TERM #1 BROWN &RED (CIRCUIT 1 & 2) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Optex OS-12C Controller RED TERM #4 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WHITE TERM #5 EXTERIOR ACUSENSOR PT. NO. 14-8902 YELLOW GRAY BROWN BLK/RED P/N 14-11874 N/O N/C Common SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT. A OUT. B OUT. C OU T 7 HANDY TERMINAL 6P Microprocessor Controller 248901- No. FUNCTION (SLIDING DOOR) 12VDC + 12VDC-(Common) Interior Acvao n Holding Beam Reduced Opening Switch Power Harness ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED INTERIOR ACUSENSOR PT. NO. 14-8902 YELLOW GRAY BROWN BLK MAIN HARNESS FOR U30 P/N 24-11877 ERROR BA 62 H 6B 61 POWER MOTOR 12P U30 MICROPROCESSOR CONTROL P/N 24-8901-30 Part #15-10596-30 REDUCED OPEN RED BLUE WHITE BLUE TB2 Auxiliary 120 VAC Power Wires (These wires are normally POWER SUPPLY ASSEMBLY P/N 9418800100 NABCO ENTRANCES, INC. 14-11741 T1 9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7 U30 MICROPROCESSOR CONTROL LABEL Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V (42.4V peak) max. 5A max, (0-20V), 3.2A max. (20-30V) Auxiliary Output (Open Collector) 12VDC Common Mode Switch Holding Beam Reduced Opening Switch S1 PRESS TO RESET RED INDICATES POWER IS OFF -CIRCUIT-BREAKER- NOISE FILTER 8 12 VDC+ 12VDC- (Common) P/N 14-11872 TB1 ON/OFF Power Switch PE Grounding Wire (Common) White Wire AC115V ± 10% 50 / 60 Hz MOTOR/OPERATOR P/N 24-11327 3 2 4 INDICATORS POWER 2P 20VAC 50/60Hz POWER SUPPLY P/N 14-11741 RELATED DEVICES・16P 5-14 N 7 6 5 L 10 9 Related Devices - 16P >POM < Black Wire (Hot) Electrical Installation Manual U-30 Control www.NabcoEntrances.com Rev. 1-10-14 CHAPTER 5: WIRING DIAGRAMS Section 5a: (2) Acusensors and (1) Holding Beam Wiring Diagrams (Surface Applied Sliders) Wiring Diagrams (Surface Applied Sliders) Common N/O N/C LOAD TWO WAY FULL OPEN ORANGE RED REDUCED OPEN RED ORG/WHT RED GREEN ORG/WHT RED ORANGE BLUE WHITE WHITE BLUE WHITE WHITE U30 TERMINAL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 MAGNETIC POWER DOWN SWITCH P/N 22-9222 WHITE BLUE BLUE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 NABCO WHITE RED RED ORG/WHT BLUE GREEN ORANGE BLUE BROWN RED BLACK WHITE GREEN ORANGE ORG/WHT BLK/RED YELLOW BLUE GRN/WHT MADE IN JAPAN Nabtesco Corporation DS-1500 D24-113270 GYRO TECH NABCO NA BC 3 2 1 1211 7 0 ! ! M0 Open Gn d Gn d Open Mode SW Usage MODE M1 Open TWO WAY Open ONE WAY Gn d HOLD OPEN Gn d NIGH T ! WARNING To protect against risk of Fire or electric shock,use only the cerfied NABCO power supply. To maintain warranty,repairs must be made by authorized NABCO facilities. Do not disassemble the control box. There are no user serviceable parts inside. Adjustments to the door can only be made with the NABCO Handy Terminal. ! CAUTION GYRO TECH NABCO GRAY WHITE GRAY ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED U30 TERMINAL P/N 24-11877 DN 0685 OPTEX HOLDING BEAM CONTROLLER PT. NO. PN 14-9710-03 TERM #1 BROWN &RED (CIRCUIT 1 & 2) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Optex OS-12C Controller RED TERM #4 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WHITE TERM #5 N/O N/C Common EXTERIOR OPTEX I-1 PT. NO. 14-13036 YELLOW GRAY YELLOW Mode Switch (see Mode SW Usage shown le) Exterio r Acvaon Sequenal Acvaon Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT. A OUT. B OUT. C OU T 7 HANDY TERMINAL 6P Microprocessor Controller 248901- No. FUNCTION (SLIDING DOOR) 12VDC + 12VDC-(Common) Interior Acvao n Holding Beam Reduced Opening Switch BLK BROWN BLK/RED OPTEX HARNESS P/N 12-13018 WHITE GRAY ERROR BA 62 H 6B ! MOTOR 12P 61 POWER Power Harness P/N 14-11874 ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED INTERIOR OPTEX I-1 PT. NO. 14-13036 YELLOW GRAY YELLOW GRAY BROWN BLK MAIN HARNESS FOR U30 P/N 24-11877 O U30 MICROPROCESSOR CONTROL P/N 24-8901-30 Rev. 1-10-14 HOLD OPEN ONE WAY NIGHT OFF ON BACK SIDE OF ROCKER SWITCH SHOWN ROCKER SWITCH FOR U30 PN 14-11875 KEY SWITCH FOR U30 PN 14-11876 TB2 Auxiliary 120 VAC Power Wires (These wires are normally POWER SUPPLY ASSEMBLY P/N 9418800100 NABCO ENTRANCES, INC. 14-11741 T1 9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7 U30 MICROPROCESSOR CONTROL LABEL Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V (42.4V peak) max. 5A max, (0-20V), 3.2A max. (20-30V) Auxiliary Output (Open Collector) 12VDC Common Mode Switch Holding Beam Reduced Opening Switch S1 PRESS TO RESET RED INDICATES POWER IS OFF -CIRCUIT-BREAKER- NOISE FILTER ON/OFF Power Switch TB1 MOTOR/OPERATOR P/N 24-11327 RELATED DEVICES・16P POWER SUPPLY P/N 14-11741 8 12 VDC+ 12VDC- (Common) Grounding Wire P/N 14-11872 White Wire (Common) AC115V ± 10% 50 / 60 Hz PE 4 INDICATORS POWER 2P 20VAC 50/60Hz N 7 6 5 L 10 9 Related Devices - 16P >POM < Black Wire (Hot) www.NabcoEntrances.com Electrical Installation Manual U-30 Control Part #15-10596-30 Section 5b: (2) Optex i-One Sensors and (1) Holding Beam 5-15 S1 PRESS TO RESET RED INDICATES POWER IS OFF -CIRCUIT-BREAKER- NOISE FILTER Common N/O N/C LOAD TWO WAY HOLD OPEN ONE WAY NIGHT OFF ON BACK SIDE OF ROCKER SWITCH SHOWN ROCKER SWITCH FOR U30 P/N 14-11875 KEY SWITCH FOR U30 P/N 14-11876 FULL OPEN ORANGE RED ORG/WHT RED GREEN ORG/WHT RED ORANGE WHITE ROCKER SWITCH EXTENSION HARNESS FOR U30 P/N 14-11884 MAGNETIC POWER DOWN SWITCH P/N 22-9222 WHITE BLUE MADE IN JAPAN Nabtesco Corporation DS-1500 D24-113270 BLUE RED RED ORG/WHT BLUE GREEN ORANGE BROWN RED BLACK WHITE GREEN ORANGE ORG/WHT BLK/RED YELLOW BLUE GRN/WHT WHITE U30 TERMINAL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 NABCO GY RO TECH NABCO O BC 11 1 12 7 0 4 32 ERROR BA 62 H ! WARNING To maintain warranty,repairs must be made by authorized NABCO facilities. Do not disassemble the control box. There are no user serviceable parts inside. Adjustments to the door can only be made with the NABCO Handy Terminal. ! CAUTION Mode SW Usage M0 MODE M1 Open Open TWO WAY Open ONE WAY Gnd GndG nd HOLD OPEN Open Gnd NIGHT To protect against risk of fire or electric shock,use only the certified NABCO power supply. FUNCTION [SLIDING DOOR] Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) Interior Activation Holding Beam Reduced Opening Switch Mode Switch (see Mode SW Usage shown left) N/O N/C Common SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT.A OUT.B OUT.C OUT 7 HANDY TERMINAL・6P Microprocessor Controller 248901- No. 12VDC-(Common) 12VDC+ No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 BLUE (TERM #4) BLUE (TERM #3) U30 TERMINAL P/N 14-11873 OPTEX OS-12C Controller TERM #1 TERM #1 BROWN &RED (TERM 1 & 2) OPTEX OS-12C Controller BROWN &RED (TERM 1 & 2) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DN 0541 OPTEX OPTEX HOLDING BEAM BREAKOUT BEAM CONTROLLER CONTROLLER PT. NO. PT. NO. P/N 14-9710-03 P/N 14-9710-03 ACUSENSOR EXTENSION HARNESS P/N 22-9267-00 RED RED WHITE (TERM #5) RED (TERM #4) EXTERIOR ACUSENSOR P/N 148902 YELLOW GRAY BROWN BLK/RED WHITE Power Harness (P/N 14-11874) ! ! ! NABCO GYRO TECH MOTOR・12P 6B 61 POWER ACUSENSOR EXTENSION HARNESS P/N 22-9267-00 RED RED INTERIOR ACUSENSOR P/N 148902 YELLOW GRAY BROWN BLK Main Harness For U30 P/N 24-11877 NA U30 MICROPROCESSOR CONTROLLER P/N 24-8901-30 Part #15-10596-30 REDUCED OPEN RED BLUE WHITE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 BLUE 9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7 U30 MICROPROCESSOR CONTROLLER LABEL Mode Switch (See Mode SW Usage Shown Le) Exterior Acvaon Sequenal Acvaon Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V (42.4V peak) max. 5A max, (0-20V), 3.2A max. (20-30V) Auxiliary Output (Open Collector) 12VDC Common TB2 Auxiliary 120 VAC Power Wires (These wires are normally coiled and ed up) POWER SUPPLY ASSEMBLY P/N 9418800100 NABCO ENTRANCES, INC. 14-11741 T1 8 12 VDC+ 12VDC- (Common) Interior Acvaon Holding Beam Reduced Opening Switch P/N 14-11872 TB1 ON/OFF Power Switch PE Grounding Wire (Common) White Wire AC115V ± 10% 50 / 60 Hz MOTOR/OPERATOR P/N 24-11327 INDICATORS POWER SUPPLY P/N 14-11741 RELATED DEVICES・16P 5-16 N POWER・2P 20VAC 50/60Hz L 7 6 5 Black Wire (Hot) >POM < 10 9 Related Devices - 16P HANDY TERMINAL HARNESS P/N 14-11837 Electrical Installation Manual U-30 Control www.NabcoEntrances.com Rev. 1-10-14 Section 5c: (2) Acusensors, (1) Holding Beam and (1) Breakout Beam Wiring Diagrams (Surface Applied Sliders) Wiring Diagrams (Surface Applied Sliders) S1 PRESS TO RESET RED INDICATES POWER IS OFF -CIRCUIT-BREAKER- Common N/O N/C LOAD TWO WAY HOLD OPEN ONE WAY NIGHT OFF ON BACK SIDE OF ROCKER SWITCH SHOWN ROCKER SWITCH FOR U30 PN 14-11875 KEY SWITCH FOR U30 PN 14-11876 FULL OPEN ORANGE RED ORG/WHT RED GREEN ORG/WHT RED ORANGE WHITE WHITE WHITE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ROCKER SWITCH EXTENSION HARNESS FOR U30 PN 14-11884 MADE IN JAPAN Nabtesco Corporation DS-1500 D24-113270 BLUE RED RED ORG/WHT BLUE GREEN ORANGE BROWN RED BLACK WHITE GREEN ORANGE ORG/WHT BLK/RED YELLOW BLUE GRN/WHT WHITE U30 TERMINAL MAGNETIC POWER DOWN SWITCH P/N 22-9222 WHITE BLUE BLUE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 NABCO GY RO TECH NA O BC 7 0 11 1 12 MOTOR/OPERATOR P/N 24-11327 INDICATORS H ERROR BA 62 Adjustments to the door can only be made with the NABCO Handy Terminal. ! CAUTION Mode SW Usage M0 MODE M1 Open Open TWO WAY Open ONE WAY Gnd GndG nd HOLD OPEN Open Gnd NIGHT To maintain warranty,repairs must be made by authorized NABCO facilities. Do not disassemble the control box. There are no user serviceable parts inside. FUNCTION [SLIDING DOOR] Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) Interior Activation Holding Beam Reduced Opening Switch Mode Switch (see Mode SW Usage shown left) N/O N/C Common SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT.A OUT.B OUT.C OUT 7 HANDY TERMINAL・6P Microprocessor Controller 248901- No. 12VDC+ 12VDC-(Common) No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WHITE GRAY ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED BLUE (TERM #4) BLUE (TERM #3) U30 TERMINAL P/N 14-11873 TERM #1 TERM #1 BROWN &RED (TERM 1 & 2) DN 0542 OPTEX OPTEX HOLDING BEAM BREAKOUT BEAM CONTROLLER CONTROLLER PT. NO. PT. NO. PN 14-9710-03 PN 14-9710-03 Optex OS-12C Controller BROWN &RED (TERM 1 & 2) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Optex OS-12C Controller RED TERM #4 WHITE TERM #5 EXTERIOR OPTEX I-ONE PN 14-10364-A YELLOW GRAY YELLOW GRAY BROWN BLK/RED OPTEX HARNESS PN 12-13018 WHITE GRAY ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED INTERIOR OPTEX I-ONE PN 14-10364-A YELLOW GRAY YELLOW GRAY BROWN BLK MAIN HARNESS FOR U30 P/N 24-11877 ! WARNING To protect against risk of fire or electric shock,use only the certified NABCO power supply. RELATED DEVICES・16P U30 MICROPROCESSOR CONTROLLER P/N 24-8901-30 ! ! ! NABCO GYRO TECH MOTOR・12P 6B 61 POWER Power Harness P/N 14-11874 NABCO Rev. 1-10-14 REDUCED OPEN RED BLUE WHITE BLUE TB2 Auxiliary 120 VAC Power Wires (These wires are POWER SUPPLY ASSEMBLY P/N 9418800100 NABCO ENTRANCES, INC. 14-11741 T1 9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7 U30 MICROPROCESSOR CONTROLLER LABEL Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V (42.4V peak) max. 5A max, (0-20V), 3.2A max. (20-30V) Auxiliary Output (Open Collector) 12VDC Common Mode Switch Holding Beam Reduced Opening Switch 12 VDC+ 12VDC- (Common) P/N 14-11872 PE ON/OFF Power Switch TB1 NOISE FILTER 8 Grounding Wire (Common) White Wire AC115V ± 10% 50 / 60 Hz 32 4 N POWER・2P 20VAC 50/60Hz L 7 6 5 POWER SUPPLY P/N 14-11741 10 9 Related Devices - 16P >POM < Black Wire (Hot) www.NabcoEntrances.com Electrical Installation Manual U-30 Control Part #15-10596-30 Section 5d: (2) Optex i-One Sensors, (1) Holding Beam and (1) Breakout Beam 5-17 S1 PRESS TO RESET RED INDICATES POWER IS OFF -CIRCUIT-BREAKER- N/O N/C Common LOAD TWO WAY HOLD OPEN ONE WAY NIGHT OFF ON BACK SIDE OF ROCKER SWITCH SHOWN ROCKER SWITCH FOR U30 PN 14-11875 KEY SWITCH FOR U30 PN 14-11876 FULL OPEN ORG/WHT RED GREEN ORG/WHT RED ORANGE WHITE WHITE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WHITE BLUE RED RED ORG/WHT BLUE GREEN ORANGE O BC 7 0 11 1 12 MOTOR/OPERATOR P/N 24-11327 INDICATORS H ERROR BA 62 YELLOW BLACK BLUE GREEN On Remote Control Set: “F1” to “1” If programming without the Remote: Parameter “13” to “1” RED BROWN WHITE ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED WIZARD G3 PN 14-13036 GRAY BROWN BLK MAIN HARNESS FOR U30 P/N 24-11877 ! WARNING To maintain warranty,repairs must be made by authorized NABCO facilities. Do not disassemble the control box. There are no user serviceable parts inside. Adjustments to the door can only be made with the NABCO Handy Terminal. ! CAUTION Mode SW Usage M0 MODE M1 Open Open TWO WAY Open ONE WAY Gnd GndG nd HOLD OPEN Open Gnd NIGHT To protect against risk of fire or electric shock,use only the certified NABCO power supply. FUNCTION [SLIDING DOOR] Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) Interior Activation Holding Beam Reduced Opening Switch Mode Switch (see Mode SW Usage shown left) N/O N/C Common SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT.A OUT.B OUT.C OUT 7 HANDY TERMINAL・6P Microprocessor Controller 248901- No. 12VDC+ 12VDC-(Common) No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 RELATED DEVICES・16P BLACK BLUE GREEN YELLOW GRAY RED BROWN WHITE ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED U30 TERMINAL P/N 14-11873 Optex OS-12C Controller TERM #1 BROWN &RED (c IRc UIt 1 & 2) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DN 0554 OPTEX HOLDING BEAM CONTROLLER PT. NO. PN 14-9710-03 WHITE TERM #5 WIZARD G3 PN 14-13036 BROWN BLK/RED RED TERM #4 U30 MICROPROCESSOR CONTROLLER P/N 24-8901-30 ! ! ! NABCO GYRO TECH MOTOR・12P 6B 61 POWER Power Harness P/N 14-11874 NA White and Green wires from Sensor provide output for ROCKER SWITCH EXTENSION HARNESS FOR U30 PN 14-11884 MADE IN JAPAN Nabtesco Corporation DS-1500 D24-113270 BROWN RED BLACK WHITE GREEN ORANGE ORG/WHT BLK/RED YELLOW BLUE GRN/WHT WHITE U30 TERMINAL MAGNETIC POWER DOWN SWITCH P/N 22-9222 WHITE BLUE BLUE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 NABCO GY RO TECH NABCO Part #15-10596-30 ORANGE RED REDUCED OPEN RED BLUE WHITE TB2 Auxiliary 120 VAC Power Wires (These wires are POWER SUPPLY ASSEMBLY P/N 9418800100 NABCO ENTRANCES, INC. 14-11741 T1 9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7 U30 MICROPROCESSOR CONTROL LABEL Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V (42.4V peak) max. 5A max, (0-20V), 3.2A max. (20-30V) Auxiliary Output (Open Collector) 12VDC Common Mode Switch Holding Beam Reduced Opening Switch 12 VDC+ 12VDC- (Common) P/N 14-11872 PE ON/OFF Power Switch TB1 NOISE FILTER 8 Grounding Wire (Common) White Wire AC115V ± 10% 50 / 60 Hz 32 4 5-18 N POWER・2P 20VAC 50/60Hz L 7 6 5 POWER SUPPLY P/N 14-11741 10 9 Related Devices - 16P >POM < Black Wire (Hot) Electrical Installation Manual U-30 Control www.NabcoEntrances.com Rev. 1-10-14 Section 5e: (2) Wizard G3, and (1) Holding Beam Wiring Diagrams (Surface Applied Sliders) Wiring Diagrams (Surface Applied Sliders) S1 PRESS TO RESET RED INDICATES POWER IS OFF -CIRCUIT-BREAKER- Common N/O N/C LOAD TWO WAY HOLD OPEN ONE WAY NIGHT OFF ON BACK SIDE OF ROCKER SWITCH SHOWN ROCKER SWITCH FOR U30 PN 14-11875 KEY SWITCH FOR U30 PN 14-11876 FULL OPEN ORANGE RED ORG/WHT RED GREEN ORG/WHT RED ORANGE WHITE WHITE WHITE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 BLUE RED RED ORG/WHT BLUE GREEN ORANGE O BC 11 1 12 7 0 MOTOR/OPERATOR P/N 24-11327 INDICATORS ERROR BA 62 H YELLOW BLACK BLUE GREEN On Remote Control Set: “F1” to “1” If programming without the Remote: Parameter “13” to “1” RED BROWN WHITE ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED WIZARD G3 PN 14-13036 GRAY BROWN BLK MAIN HARNESS FOR U30 P/N 24-11877 ! WARNING To maintain warranty,repairs must be made by authorized NABCO facilities. Do not disassemble the control box. There are no user serviceable parts inside. Adjustments to the door can only be made with the NABCO Handy Terminal. ! CAUTION Mode SW Usage M0 MODE M1 Open Open TWO WAY Open ONE WAY Gnd GndG nd HOLD OPEN Open Gnd NIGHT To protect against risk of fire or electric shock,use only the certified NABCO power supply. FUNCTION [SLIDING DOOR] Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) Interior Activation Holding Beam Reduced Opening Switch Mode Switch (see Mode SW Usage shown left) N/O N/C Common SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT.A OUT.B OUT.C OUT 7 HANDY TERMINAL・6P Microprocessor Controller 248901- No. 12VDC+ 12VDC-(Common) No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 RELATED DEVICES・16P BLACK BLUE GREEN YELLOW GRAY RED BROWN WHITE ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED BLUE (TERM #4) BLUE (TERM #3) U30 TERMINAL P/N 14-11873 Optex OS-12C Controller TERM #1 TERM #1 BROWN &RED (TERM 1 & 2) Optex OS-12C Controller BROWN &RED (TERM 1 & 2) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DN 0555 OPTEX OPTEX HOLDING BEAM BREAKOUT BEAM CONTROLLER CONTROLLER PT. NO. PT. NO. PN 14-9710-03 PN 14-9710-03 WHITE TERM #5 WIZARD G3 PN 14-13036 BROWN BLK/RED RED TERM #4 U30 MICROPROCESSOR CONTROLLER P/N 24-8901-30 ! ! ! NABCO GYRO TECH MOTOR・12P 6B 61 POWER Power Harness P/N 14-11874 NA White and Green wires from Sensor provide output for ROCKER SWITCH EXTENSION HARNESS FOR U30 PN 14-11884 MADE IN JAPAN Nabtesco Corporation DS-1500 D24-113270 BROWN RED BLACK WHITE GREEN ORANGE ORG/WHT BLK/RED YELLOW BLUE GRN/WHT WHITE U30 TERMINAL MAGNETIC POWER DOWN SWITCH P/N 22-9222 WHITE BLUE BLUE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 NABCO GY RO TECH NABCO Rev. 1-10-14 REDUCED OPEN RED BLUE WHITE BLUE TB2 Auxiliary 120 VAC Power Wires (These wires are POWER SUPPLY ASSEMBLY P/N 9418800100 NABCO ENTRANCES, INC. 14-11741 T1 9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7 U30 MICROPROCESSOR CONTROLLER LABEL Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V (42.4V peak) max. 5A max, (0-20V), 3.2A max. (20-30V) Auxiliary Output (Open Collector) 12VDC Common Mode Switch Holding Beam Reduced Opening Switch 12 VDC+ 12VDC- (Common) P/N 14-11872 PE ON/OFF Power Switch TB1 NOISE FILTER 8 Grounding Wire (Common) White Wire AC115V ± 10% 50 / 60 Hz 32 4 N POWER・2P 20VAC 50/60Hz L 7 6 5 POWER SUPPLY P/N 14-11741 10 9 Related Devices - 16P >POM < Black Wire (Hot) www.NabcoEntrances.com Electrical Installation Manual U-30 Control Part #15-10596-30 Section 5f: (2) Wizard G3, (1) Holding Beam and (1) Breakout Beam 5-19 Electrical Installation Manual U-30 Control www.NabcoEntrances.com Part #15-10596-30 Rev. 1-10-14 CHAPTER 6: INFRARED BEAM WIRING Section 6a: Wiring (1) Holding Beam On GT-1175 Slide doors, the Optex OS-12C Module Infrared Beam is installed and wired at the NABCO factory. This unit is shipped complete with the following: ►►Emitter ►►Receiver ►►Control Box Both the Emitter and Receiver are flush mounted on both sides of the Slide door Frame or each Jamb tube, directly across from each other. A pulsed, infrared light beam is used to continuously transmit across the Slide door opening. Interruption of the infrared light beam will switch the White holding beam input wire to Red (Common). Thus causing the system to re-activate and Hold Open until the interruption is cleared. Please Figure 6-1. T1 NABCO N NA PE INDICATORS 4 3 2 1211 7 0 8 N/O N/C Common 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 U30 MICROPROCESSOR CONTROL LABEL Related Devices - 16P 7 6 5 Mode Switch Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V (42.4V peak) max. 5A max, (0-20V), 3.2A max. (20-30V) Auxiliary Output (Open Collector) 12VDC Common 1 10 9 Holding Beam Reduced Opening Switch 9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ! CAUTION ! Adjustments to the door can only be made with the NABCO Handy Terminal. Do not disassemble the control box. There are no user serviceable parts inside. ! To maintain warranty,repairs must be made by authorized NABCO facilities. HANDY TERMINAL 6P No. Microprocessor Controller 248901FUNCTION (SLIDING DOOR) 12VDC + 12VDC-(Common) Interior Acvao n Holding Beam Reduced Opening Switch Mode Switch (see Mode SW Usage shown le) Exterio r Acvaon Sequenal Acvaon Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) N/O N/C Common SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT. A OUT. B OUT. C OU T 7 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WHITE CONNECT EACH TERMINAL THE SAME TERM #1 TERM #5 Yellow Optex OS-12C Controller P/N 14-9710-03 Jacket Color Braided Shield TERM #6 BLUE TERM #6 YELLOW TERM #7 OTHER WIRES NOT SHOWN FOR SIMPLICITY DN 0547 GRAY EMTR 1 6-20 Mode SW Usage MODE M1 Open TWO WAY Open ONE WAY Gn d HOLD OPEN Gn d NIGH T RED TERM #13 GRAY TERM #10 M0 Open Gn d Gn d Open BROWN & RED CIRCUIT 1 & 2 U30 TERMINAL P/N 14-11873 YELLOW TERM #11 H 62 ERROR S1 12 VDC+ 12VDC- (Common) GYRO TECH 6B BA MADE IN JAPAN ! WARNING To protect against risk of Fire or electric shock,use only the cerfied NABCO power supply. ! NABCO 61 Nabtesco Corporation POWER SUPPLY ASSEMBLY P/N 9418800100 NABCO ENTRANCES, INC. 14-11741 PRESS TO RESET MOTOR 12P POWER DS-1500 D24-113270 POWER 2P 20VAC 50/60Hz RED INDICATES POWER IS OFF O GYRO TECH LOAD -CIRCUIT-BREAKER- BC NABCO TB2 TB1 >POM < NOISE FILTER L AC115V ± 10% 50 / 60 Hz U30 MICROPROCESSOR CONTROL P/N 24-8901-30 MOTOR/OPERATOR P/N 24-11327 RELATED DEVICES・16P POWER SUPPLY P/N 14-11741 BLUE RCVR 1 Figure 6-1 (1) Holding Beam using Optex OS-12C Controller Infrared Beam Wiring www.NabcoEntrances.com Electrical Installation Manual U-30 Control Rev. 1-10-14 Part #15-10596-30 Section 6b: Wiring (2) Holding Beams On GT-1175 Slide doors, the Optex OS-12C Module Infrared Beam is installed and wired at the NABCO factory. This unit is shipped complete with the following: ►►Emitter ►►Receiver ►►Control Box Both the Emitters and Receivers are flush mounted on both sides of the Slide door Frame or each Jamb tube, directly across from each other (in pairs). Please see Figure 6-2 and Figure 6-3. Emit Rcvr ① ② Emit Rcvr DN 0549 Figure 6-2 Transmission of Infrared Light Beams A pulsed, infrared light beam is used to continuously transmit across the Slide door opening. Interruption of the infrared light beam will switch the White holding beam input wire to Red (Common). Thus causing the system to re-activate and Hold Open until the interruption is cleared. TO U30 CONTROLLER TERMINAL TO AUXILIARY POWER SUPPLY CONNECT EACH TERMINAL THE SAME TERM #1 TERM #5 Yellow Optex OS-12C Controller P/N 14-9710-03 YELLOW TERM #13 BLUE TERM #6 GRAY TERM #12 YELLOW TERM #11 GRAY TERM #10 DN 0548 Infrared Beam Wiring Braided Shield TERM #13 YELLOW TERM #9 Plasc Conductor TERM #6 YELLOW TERM #7 BLUE TERM #8 Jacket Color BLUE RCVR 2 GRAY EMTR 1 GRAY EMTR 2 OTHER WIRES NOT SHOWN FOR SIMPLICITY BLUE RCVR 1 Figure 6-3 (2) Holding Beams using Optex OS-12C Controller 6-21 Electrical Installation Manual U-30 Control www.NabcoEntrances.com Part #15-10596-30 Rev. 1-10-14 Section 6c: Wiring Holding Beam for Breakout On GT-1175 Slide doors, the Optex OS-12C Module Infrared Beam is installed and wired at the NABCO factory. This unit is shipped complete with the following: ►►Emitter ►►Receiver ►►Control Box Both the Emitter and Receiver are flush mounted on both sides of the Slide door Frame or each Jamb tube, directly across from each other. A pulsed, infrared light beam is used to continuously transmit across the Slide door opening. Interruption of the infrared light beam. By Breaking Out a Slide door panel the Blue (BA) wire power down loop will be interrupted. Thus causing the system to stop operating until the Slide door is repositioned and latched. Please see Figure 6-4. T1 NABCO N NA PE INDICATORS 4 3 2 1211 7 0 8 N/O N/C Common 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 U30 MICROPROCESSOR CONTROL LABEL Related Devices - 16P 7 6 5 Mode Switch Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V (42.4V peak) max. 5A max, (0-20V), 3.2A max. (20-30V) Auxiliary Output (Open Collector) 12VDC Common 1 10 9 Holding Beam Reduced Opening Switch 9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Mode SW Usage MODE M1 Open TWO WAY Open ONE WAY Gn d HOLD OPEN Gn d NIGH T ! CAUTION ! Adjustments to the door can only be made with the NABCO Handy Terminal. Do not disassemble the control box. There are no user serviceable parts inside. ! To maintain warranty,repairs must be made by authorized NABCO facilities. HANDY TERMINAL 6P No. Microprocessor Controller 248901FUNCTION (SLIDING DOOR) 12VDC + 12VDC-(Common) Interior Acvao n Holding Beam Reduced Opening Switch Mode Switch (see Mode SW Usage shown le) Exterio r Acvaon Sequenal Acvaon Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) N/O N/C Common SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT. A OUT. B OUT. C OU T 7 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 RED CONNECT EACH TERMINAL THE SAME BLUE TERM #5 TERM #1 Yellow Optex OS-12C Controller P/N 14-9710-03 TERM #13 GRAY TERM #10 M0 Open Gn d Gn d Open BROWN & RED CIRCUIT 1 & 2 U30 TERMINAL P/N 14-11873 YELLOW TERM #11 H 62 ERROR S1 12 VDC+ 12VDC- (Common) GYRO TECH 6B BA MADE IN JAPAN ! WARNING To protect against risk of Fire or electric shock,use only the cerfied NABCO power supply. ! NABCO 61 Nabtesco Corporation POWER SUPPLY ASSEMBLY P/N 9418800100 NABCO ENTRANCES, INC. 14-11741 PRESS TO RESET MOTOR 12P POWER DS-1500 D24-113270 POWER 2P 20VAC 50/60Hz RED INDICATES POWER IS OFF O GYRO TECH LOAD -CIRCUIT-BREAKER- BC NABCO TB2 TB1 >POM < NOISE FILTER L AC115V ± 10% 50 / 60 Hz U30 MICROPROCESSOR CONTROL P/N 24-8901-30 MOTOR/OPERATOR P/N 24-11327 RELATED DEVICES・16P POWER SUPPLY P/N 14-11741 Jacket Color Braided Shield TERM #6 BLUE TERM #6 YELLOW TERM #7 OTHER WIRES NOT SHOWN FOR SIMPLICITY DN 0547 GRAY EMTR 1 BLUE RCVR 1 Figure 6-4 Breakout Beam using Optex OS-12C Controller 6-22 Infrared Beam Wiring www.NabcoEntrances.com Electrical Installation Manual U-30 Control Rev. 1-10-14 Part #15-10596-30 CHAPTER 7: ELECTRIC LOCK WIRING Note: Electric Locks can not prevent Breakout. If preventing Breakout is deemed necessary, panic hardware must be fitted to the Door Panels. The Electric Lock is optional and can come in (1 of 2) configurations: ►►Fail Safe • Allows the Door Panel to be manually opened if power is turned Off. • Will not allow the Door Panal to be manually opened if power is turned Off. ►►Fail Secure Electric Locks are used to prevent Door Panels from opening until they are activated by the U30 Microprocessor Control when it receives a signal from a: ►►Remote Switch ►►Transmitter ►►Activation Device on the face of the Door Electric Locks are pre-installed at the NABCO Factory. Only the Strike mounted on the Header may need to be adjusted. Section 7a: Adjust the Strike. 1. Close Door Panel(s). 2. Go inside the Header. Loosen the Strike Mounting Bolts that is holding the Strike Bracket secure to the Header. 3. Slide the Strike to align with the Latch Bolt in the fully closed position. 4. Tighten the Strike Mounting Bolts. a. Do not overtighten. Electric Lock Assembly LATCHBOLT POSITION: • BIPART UNITS • LH SINGLE F.O. • RH SINGLE F.S. Dead Bolt Engaged with Electric Strike Electric Strike (Door in Full Closed Posion) Slight Gap (Between Strike Wall and Dead Bolt) Belt Clip Terminal Strip (Strike Side of Door) Dead Bolt Assembly LATCHBOLT POSITION: • RH SINGLE F.O. • LH SINGLE F.S. Electric Lock Wiring DN 1026 Figure 7-1 Adjust the Strike 7-23 GROUND HARNESS P/N 14-11872 ON/OFF POWER SWITCH S1 5 A M P T1 AUXILIARY 120 VAC POWER WIRES (THESE WIRES NORMALLY COILED AND TIED UP) 120 VAC TB2 GRAY OUTPUT TIMER 0 = (DO NOT USE) 1 = (DO NOT USE) 2 = (DO NOT USE) 3 = ELECTRIC STRIKE FUNCTION OUTPUT: 0 = ELECTRIC STRIKE OUTPUT FULLY CLOSED OPENING 3 SEC ON CLOSING FULL OPEN ON 6 FULLY CLOSED VIOLET M< >PO GRY VIO BLK WHT 110V INDICATORS H ERROR BA 62 WARNING SYMBOL No. 9DC12V 1 7 2 61 3 6B 4 H 5 M0 6 M1 7 62 8 SQ 9 BA 10 SLS 11 N/O OUT.A 12 N/C OUT.B 13 Common OUT.C 14 OUT 15 7 16 RELATED DEVICES・16P 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DN 0551 FAIL SAFE LOCK ASSY. P.N. 22-10522-04 FAIL SECURE LOCK ASSY. P.N. 22-10522-03 FAIL SAFE Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) Mode Switch (see Mode SW Usage shown left) POWER SUPPLY HARNESS P/N 14-11874 To maintain warranty,repairs must be made by authorized NABCO facilities. Do not disassemble the control box. There are no user serviceable parts Adjustments to the door can only be made with the NABCO Handy Terminal. CAUTION HANDY TERMINAL・6P Microprocessor Controller 248901- No. Mode SW Usage M0 M1 MODE Open Open TWO WAY FUNCTION [SLIDING DOOR] Gnd Open ONE WAY 12VDC+ Gnd Gnd HOLD OPEN 12VDC-(Common) Open Gnd NIGHT Interior Activation Holding Beam Reduced Opening Switch To protect against risk of fire or electric shock,use only the certified NABCO power supply. OTHER WIRES NOT SHOWN FOR SIMPLICITY 6 1 61 6B GYRO TECH MOTOR・12P POWER U30 CONTROL P/N 24-8901-30 Part #15-10596-30 OUTPUT TIMER 1.0 SEC OUTPUT SIGNAL OFF ACTIVATION SIGNAL OFF U30 ELECTRIC STRIKE OUTPUT SIGNAL HANDY TERMINAL: AUX OUTPUT = 0, OUTPUT TIMER = 3, ROCKER SWITCH SETTING: ONE WAY OR NIGHT MODE WIRING FOR ELECTRIC LOCK ONLY SHOWN P/N 24-11877 SYMBOL No. 9DC12V 1 1 7 2 2 61 3 3 6B 4 4 5 H 5 M0 6 6 7 M1 7 Exterior Activation 62 8 8 Sequential Activation SQ 9 9 Breakout Detector 10 BA 10 11 Sidelite Presence Sensor SLS 11 Contact Output (Class2 Load only) 12 N/O OUT.A 12 FAIL SECURE (OUT A) 30V(42.4Vpeak)max. FAIL SAFE (OUT B) 13 N/C OUT.B 13 5Amax.(0-20V), 3.2Amax.(20-30V) 14 14 Common OUT.C Auxiliary Output (Open-Collector) 15 OUT 15 16 7 16 12VDC-COMMON LABEL ON U30 CONTROL TERMINAL ON U30 MAIN HARNESS FUNCTION [SLIDING DOOR] 12VDC+ 12VDC-(COMMON) INTERIOR ACTIVATION HOLDING BEAM REDUCED OPENING SWITCH Mode Switch (see Mode SW Usage shown left) GROUND LUG SCREW TO HEADER BLACK (HOT) WHITE (COMMON) AC115V ± 10% 50 / 60 Hz TB1 ZN R2 ZN R1 NOISE FILTER TRANSFORMER MOTOR/OPERATOR P/N 24-11327 MADE IN JAPAN POWER SUPPLY P/N 14-11741 GYRO TECH DS-150NA (24-11327) RELATED DEVICES - 16P Note: POWER・2P 20VAC 50/60Hz 0 7 8 9 10 11 12 1 7-24 2 34 HANDY TERMINAL HARNESS P/N 14-11837 Electrical Installation Manual U-30 Control www.NabcoEntrances.com Rev. 1-10-14 Section 7b: U30 with Fail Safe Electric Lock Fail Safe Electric Lock only works in One Way mode or Night Mode. Electric Lock Wiring 5 A M P GROUND HARNESS P/N 14-11872 ON/OFF POWER SWITCH S1 T1 TB2 AUXILIARY 120 VAC POWER WIRES (THESE WIRES NORMALLY COILED AND TIED UP) 120 VAC TRANSFORMER MOTOR/OPERATOR P/N 24-11327 OUTPUT TIMER 0 = (DO NOT USE) 1 = (DO NOT USE) 2 = (DO NOT USE) 3 = ELECTRIC STRIKE FUNCTION OUTPUT: 0 = ELECTRIC STRIKE OUTPUT OPENING 3 SEC ON FULLY CLOSED OFF ON CLOSING FULL OPEN FULLY CLOSED GRY VIO BLK WHT 110V 6 1 61 ERROR BA 62 H 6B WARNING CAUTION HANDY TERMINAL・6P Microprocessor Controller 248901- No. INDICATORS POWER SUPPLY HARNESS P/N 14-11874 To maintain warranty,repairs must be made by authorized NABCO facilities. Do not disassemble the control box. There are no user serviceable parts inside. RELATED DEVICES・16P 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DN 0552 FAIL SECURE LOCK ASSY. P.N. 22-10522-03 FAIL SECURE Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) Mode Switch (see Mode SW Usage shown left) SYMBOL No. 9DC12V 1 7 2 61 3 6B 4 H 5 M0 6 M1 7 62 8 9 SQ BA 10 SLS 11 N/O OUT.A 12 N/C OUT.B 13 Common OUT.C 14 OUT 15 7 16 Mode SW Usage M0 M1 MODE Open Open TWO WAY FUNCTION [SLIDING DOOR] Gnd Open ONE WAY 12VDC+ Gnd Gnd HOLD OPEN 12VDC-(Common) Open Gnd NIGHT Interior Activation Holding Beam Reduced Opening Switch To protect against risk of fire or electric shock,use only the certified NABCO power supply. Adjustments to the door can only be made with the NABCO Handy Terminal. GYRO TECH MOTOR・12P POWER U30 CONTROL P/N 24-8901-30 Rev. 1-10-14 OUTPUT TIMER 1.0 SEC OUTPUT SIGNAL ACTIVATION SIGNAL OFF U30 ELECTRIC STRIKE OUTPUT SIGNAL HANDY TERMINAL: AUX OUTPUT = 0, OUTPUT TIMER = 3, ROCKER SWITCH SETTING: ONE WAY OR NIGHT MODE WIRING FOR ELECTRIC LOCK ONLY SHOWN P/N 24-11877 SYMBOL No. 9DC12V 1 1 7 2 2 61 3 3 6B 4 4 5 H 5 6 M0 6 Mode Switch (see Mode SW Usage shown left) 7 M1 7 Exterior Activation 8 62 8 Sequential Activation SQ 9 9 Breakout Detector 10 BA 10 11 Sidelite Presence Sensor SLS 11 GRAY (OUT A) Contact Output (Class2 Load only) 12 N/O OUT.A 12 30V(42.4Vpeak)max. 13 N/C OUT.B 13 VIOLET 5Amax.(0-20V), 3.2Amax.(20-30V) 14 14 Common OUT.C Auxiliary Output (Open-Collector) 15 OUT 15 16 7 16 12VDC-COMMON LABEL ON U30 CONTROL TERMINAL ON U30 MAIN HARNESS FUNCTION [SLIDING DOOR] 12VDC+ 12VDC-(COMMON) INTERIOR ACTIVATION HOLDING BEAM REDUCED OPENING SWITCH GROUND LUG SCREW TO HEADER BLACK (HOT) WHITE (COMMON) AC115V ± 10% 50 / 60 Hz TB1 R1 R2 ZN ZN NOISE FILTER POWER SUPPLY P/N 14-11741 MADE IN JAPAN DS-150NA GYRO TECH (24-11327) Electric Lock Wiring POWER・2P 20VAC 50/60Hz Note: RELATED DEVICES - 16P HANDY TERMINAL HARNESS P/N 14-11837 www.NabcoEntrances.com Electrical Installation Manual U-30 Control Part #15-10596-30 Section 7c: U30 with Fail Secure Electric Lock Fail Secure Electric Lock only works in One Way mode or Night Mode. 7-25 7-26 U-19 & Earlier BIPART SLIDE DOOR Motor/Operator 11 11/16 U-19 & Earlier Belt Clip Top Belt Clip Top 8 5/16 Relay Motor/Operator Belt Bracket Relay Belt Clip Boom Terminal Strip SINGLE SLIDE DOOR; RHFS, LHFO U-19 & Earlier Belt Bracket 11 11/16 DN 0534 Note: SINGLE SLIDE DOOR; LHFS, RHFO Motor/Operator Belt Clip Top Terminal Strip Electrical Installation Manual U-30 Control www.NabcoEntrances.com Part #15-10596-30 Rev. 1-10-14 Section 7d: U30 with Magnetic Lock Magnetic Lock only works in One Way mode or Night Mode. Electric Lock Wiring Custom Wiring RED 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 RELATED DEVICES - 16P Contact 2 Contact 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ORANGE RED ORG/WHT BLUE GREEN ORANGE ROCKER SWITCH EXTENSION HARNESS FOR U30 PT. 14-11884-10 ORG/WHT BLUE GREEN ORANGE ORG/WHT RED TERMINAL ON U30 CONTROL P/N 14-11873 CUT ROCKER SWITCH EXTENSION HARNESS AND SPLICE AS SHOWN 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT.A OUT.B OUT.C OUT 7 SYMBOL No. RED ORG/WHT BLUE GREEN ORANGE Hold Open Night Mode C losed C losed Open Open One Way Mode (Exit Only) Contact 1 Mode Two Way (Auto) Closed Open Closed Open Contact 2 NOTES: 1. BLUE WIRE MUST BE CONNETED TO RED FOR DOOR TO OPERATE. 2. IT IS RECOMENDED THAT PART NUMBER 14-11884-10 BE USED FOR THESE MODIFICATIONS. THIS WOULD ALLOW CHANGES TO, OR REVERSAL OF MODIFICATIONS TO BE MADE EASIER. 3. OTHER WIRES NOT SHOWN FOR SIMPLICITY 4. REMOTE SWITCH MUST BE DRY CONTACTS (NO VOLTAGE) 5. CAP OFF ALL UNUSED WIRES Rev. 1-10-14 DN 0553 DN 0553 From DN 0291 N/O N/C Common LABEL ON U30 CONTROL Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-COMMON Mode Switch (see Mode SW Usage shown left) FUNCTION [SLIDING DOOR] 12VDC+ 12VDC-(COMMON) INTERIOR ACTIVATION HOLDING BEAM REDUCED OPENING SWITCH www.NabcoEntrances.com Electrical Installation Manual U-30 Control Part #15-10596-30 CHAPTER 8: CUSTOM WIRING Section 8a: U30 Configured for Remote Control of Modes 8-27 S1 PRESS TO RESET TB2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Auxiliary 120 VAC Power Wires (These wires are normally coiled and tied up) POWER SUPPLY ASSEMBLY P/N 9418800100 NABCO ENTRANCES, INC. 14-11741 9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7 U30 MICROPROCESSOR CONTROL LABEL Common N/O N/C LOAD U30 TERMINAL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 RED GRN/WHT MADE IN JAPAN Nabtesco Corporation DS-1500 D24-113270 GY RO TECH NABCO NABCO NA O BC 4 32 11 1 12 7 0 SIDELITE ACUSENSOR P/N 14-8902 ERROR BA 62 H 6B 61 POWER ! WARNING To maintain warranty,repairs must be made by authorized NABCO facilities. Do not disassemble the control box. There are no user serviceable parts inside. Adjustments to the door can only be made with the NABCO Handy Terminal. ! CAUTION Mode SW Usage M0 MODE M1 Open Open TWO WAY Open ONE WAY Gnd GndG nd HOLD OPEN Open Gnd NIGHT To protect against risk of fire or electric shock,use only the certified NABCO power supply. Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) Interior Activation Holding Beam Reduced Opening Switch Mode Switch (see Mode SW Usage shown left) 12VDC-(Common) FUNCTION [SLIDING DOOR] CUT ACUSENSOR EXTENSION HARNESS AND SPLICE AS SHOWN P/N 14-11874 N/O N/C Common SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT.A OUT.B OUT.C OUT 7 HANDY TERMINAL・6P Microprocessor Controller 248901- No. 12VDC+ Power Harness ! ! ! NABCO GYRO TECH MOTOR・12P No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 U30 MICROPROCESSOR CONTROL P/N 24-8901-30 RELATED DEVICES・16P U30 TERMINAL P/N 24-11877 SIDELITE ACUSENSOR P/N 14-8902 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Part #15-10596-30 DN 0546 -CIRCUIT-BREAKERRED INDICATES POWER IS OFF ON/OFF Power Switch Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V (42.4V peak) max. 5A max, (0-20V), 3.2A max. (20-30V) Auxiliary Output (Open Collector) 12VDC Common Mode Switch Holding Beam Reduced Opening Switch 12 VDC+ 12VDC- (Common) P/N 14-11872 Grounding Wire (Common) White Wire TB1 T1 Related Devices - 16P NOISE FILTER GREEN AC115V ± 10% 50 / 60 Hz BLACK RED INDICATORS POWER・2P 20VAC 50/60Hz MOTOR/OPERATOR P/N 24-11327 GREEN POWER SUPPLY P/N 14-11741 8 WHITE PE BLACK 8-28 N 7 6 5 L RED 10 9 WHITE >POM < Black Wire (Hot) Electrical Installation Manual U-30 Control www.NabcoEntrances.com Rev. 1-10-14 Section 8b: Sidelite Sensors Custom Wiring www.NabcoEntrances.com Electrical Installation Manual U-30 Control Rev. 1-10-14 Part #15-10596-30 Section 8c: U30 Using Card Readers or other Secure Activation Devices KEY PAD OR CARD READER ON SECURE SIDE OF DOOR (N.O. - DRY CONTACTS) 1. “FUNCTION 13” UNDER “EXTRA FUNCTIONS” MUST BE SET TO “3”. 2. “FUNCTION 13” SET TO 3 ENABLES THE “SLS” INPUT TO ACTIVATE THE DOOR REGARDLESS OF THE MODE (AUTO, ONE WAY, NIGHT). 3. DEVICE MUST PROVIDE NORMALLY OPEN, DRY CONTACTS (NO VOLTAGE). 4. OTHER WIRES NOT SHOWN FOR SIMPLICITY. N.O. 12 VDC+ 12VDC- (Common) Interior Acvaon Holding Beam Reduced Opening Switch Mode Switch (See Mode SW Usage Shown Le) Exterior Acvaon Sequenal Acvaon Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V (42.4V peak) max. 5A max, (0-20V), 3.2A max. (20-30V) Auxiliary Output (Open Collector) 12VDC Common N/O N/C Common 9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7 U30 MICROPROCESSOR CONTROL LABEL P/N 24-8901-30 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Related Devices - 16P COM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TERM #11 U30 TERMINAL P/N 24-11877 NONSECURE ACTIVATION DEVICES SUCH AS PUSH PLATES CAN ALSO BE CONNECTED TO THE INTERIOR TERMINAL 3 AND COMMON¡ OR EXTERIOR TERMINAL 8 AND COMMON¡ ACTIVATION INPUTS. THIS WILL ALLOW THEM TO BE TURNED OFF OR ON BY USING THE MODE SWITCHES TWO WAY, ONE WAY, NIGHT¡ Custom Wiring TERM #2 DN 0545 8-29 Electrical Installation Manual U-30 Control www.NabcoEntrances.com Part #15-10596-30 Rev. 1-10-14 CHAPTER 9: TROUBLESHOOTING Trouble Slide door panicked open. System fails to shut down. Slide door does not open when power is applied. Do Not manually shut door. Handy Terminal screen does not change. Door opens and closes very slowly. Slide doors do not Open completely. Reset the system back to NABCO Factory settings 9-30 Action Check wiring on the magnetic power down switches. Blue (BA) circuit must open for system to shut down. XX Confirm the Breakout Panel(s) is closed completely. XX Confirm Blue (BA) circuit is not open. • Verification can be done by observing Green (BA) status LED on U30 Controller. If LED in ON, the circuit is Open, and the unit will not operate. XX Check that the power down magnet in the top rail of the Breakout panel is installed and aligned with the magnetic power down switch in the bottom of the Header. XX Confirm Rocker Switch is set to ON not OFF. XX Confirm the Breakout Panel(s) is closed completely. XX Confirm Blue (BA) circuit is not open. • Verification can be done by observing Green (BA) status LED on U30 Controller. If LED in ON, the circuit is Open, and the unit will not operate. XX Check that the power down magnet in the top rail of the Breakout panel is installed and aligned with the magnetic power down switch in the bottom of the Header. XX Confirm Rocker Switch is set to ON not OFF. XX Check and clear error codes with Handy Terminal. XX If Handy Terminal is not available, cycling the power will make the control resume normal operation. XX Look for obstructions in the track as well as inside the Header. • Check to ensure that Belt Clips are not hitting something. XX Check that the Mode Switch on the panel is not in “Reduced Opening” mode. Also verify that the Green (H) status LED on the U30 Controller is not lit. If this LED is ON, it indicates that there is a signal on the “Reduced Opening” circuit (Green “H” is being shorted to Red 7) XX Use the Handy Terminal and reintialize the system. XX Plug in Handy Terminal and wait for the Slide door to Close. 1. At “Swing/Slide Stroke?” enter YES. 2. At “Swing Door Y or N?” enter YES (even though you have a slide door). a. “Swing Door Y or N?” enter NO. b. System will now intialize as a Slide door to NABCO Factory settings. 3. Set Slide door Stroke according to prompts the Handy Terminal displays. Troubleshooting www.NabcoEntrances.com Electrical Installation Manual U-30 Control Rev. 1-10-14 Part #15-10596-30 CHAPTER 10: RETURN POLICY Note: Please call Customer Service if the Return Material tag number is not known at 1-888-679-3319. A Return Material tag is used for: ►►In Warranty and Out of Warranty materials. ►►Repair and Return. ►►Return for Credit Transactions. NABCO ENTRANCES Standard Term & Conditions and Warranty govern all returned items. These are provided in detail in the Terms & Conditions section of NABCO ENTRANCES Price Book. If you have any questions on warranty or the use of the RMA tag, please call NABCO’s Customer Service Department toll free at 1-888-679-3319. Section 10a: How to Print and Fill out a Return Material Tag 1. Go to the NABCO Website at http://nabcoentrances.com/ a. The NABCO homepage will be displayed. 2. Go to the left hand column. Under “Quick Links” click on: RMA LABELS 3. Enter the RMA number. Click on: RMA LOOKUP 4. Fill out all necessary contact information. Click on: GENERATE A LABEL a. An assigned RMA tag will be displayed. 5. Print the assigned RMA tag. a. The RMA tag is printed in triplicate. 6. Record following information on the tag: XX Serial No. or Part No. XX Part Name (description) XX Return Policy • Serial numbers for electronic components are stamped, engraved or printed on stickers and located on the component. Non-electrical parts usually do not have serial numbers. Expiration Date • Expiration dates for electronic components are stamped, engraved or printed on stickers and located on the component. Non-electrical parts usually do not have expiration dates. For “Warranty claims of non-electrical parts”, please include a photocopy of the original NABCO invoice the part was purchased on. 10-31 Electrical Installation Manual U-30 Control www.NabcoEntrances.com Part #15-10596-30 Rev. 1-10-14 XX Date Returned XX Requested Repair and Return Action XX XX XX XX • The date that the malfunctioning Unit or Part is returned to NABCO Entrances INC. • Specify in/out warranty for R&R, Exchange, or in warranty for credit. For requests for credits, please write the number of the invoice you want credited. Distributor Name Date of Installation Installed at Job Describe part problem 7. Attach an RMA tag to each malfunctioning Unit or Part that is returned to the NABCO factory. 8. The RMA tag is printed in triplicate. Please keep (top) copy of the tag. 9. Send remaining (2) copies along with each malfunctioning Unit or Part to the attention of: REPAIR AND RETURN DEPARTMENT AT NABCO ENTRANCES. a. Please remember to package the malfunctioning Unit and/or Parts properly. 10. Ship the parts freight prepaid. Note: 10-32 a. Collect shipments will be refused. All return inquiries must be accompanied with the RMA tag number associated with the malfunctioning Unit and/or part. Return Policy