Energy saving motors Second generation

Transcription

Energy saving motors Second generation
Energy saving motors
Second generation
Efficiency classes according to IEC 60034-30
Standard efficiency IE1
High efficiency IE2
Special catalogue 02-2009
Contents
Introduction
Contents
The products featured in this catalogue can also be found in the interactive electronic catalogue V 6.x.
Additional information about the
company and the products of the
VEM Group are available via internet: www.vem-group.com.
The electronic catalogue can assist
you in selecting and configuring VEM
products. You can choose to print
out data sheets and requests and
the programme can display scaled and
dimensioned drawings that can be
downloaded in different 2D and
3D-data files. In addition to general
information about the VEM group,
you have access to catalogues,
spare parts lists and operation and
maintenance manuals of the individual product types.
Introduction
Technical explanations
Efficiency limits
5
9
12
1
Energy saving motors, Standard efficiency IE1
Energy saving motors, High efficiency IE2
16
22
2
Dimensions
29
3
Introduction
Introduction
In the past years the world-wide development of energy
efficient motors has led to a variety of country-specific
regulations, laws and standards. It is therefore difficult
to establish comparable ratings for individual products.
Depending on the place of installation limit values according to the Voluntary Agreement of CEMEP (VA), NEMA,
EPAct or special Australian, Japanese or other countryspecific regulations have to be observed. These regulations might additionally vary in the applicable test specifications. Furthermore the requirements for implementing
the EuP directive “Ecodesign requirements for energyusing products” (directive 2005/32/EC) must be kept.
In autumn 2005 the CEMEP decided to renew the
Voluntary Agreement and at the same time tighten the
rules. This shall guarantee that only qualified motor
manufacturers take part. The scope and the EFF logos
remained unchanged. VEM motors has prolonged the
participation in the “Renewed Voluntary Agreement” and
thus demonstrated its willingness to force the introduction of energy-optimized motors and drive systems into
the market in close cooperation with the OEMs. Besides
these measures the European manufacturers try to focus
the world-wide activities and get in the lead with the
suggestion of its own premium class. This process of
efficiency classification can only be done in connection
with a uniform, mandatory test methodology for the
measurement and evaluation of efficiencies.
• Guide for the selection and application of energyefficient motors including variable-speed applications
(IEC TS 60034-31 Ed. 1)
This standard development is now nearly finished.
Based on the EuP study on motors and on the new
standard for efficiency classification (IEC 60034-30)
it is internationally agreed to extend the power range
to 375 kW for 2-, 4- and 6-pole motors.
As a result the following motor design specifications
form the framework of the new efficiency classification:
• Three-phase asynchronous motors for mains operation
(50 Hz, 60 Hz)
• Rated output between 0.75 and 375 kW
• 2-, 4- and 6-pole design
• Continuous operation S1 and S3 ≥ 80% ED
• Rated voltages up to 1,000 V
• Type of protection IP4. and above.
A start has been made with an ongoing standardization
development at the IEC.
In the future this scope will also include special designs
of standard motors like geared motors, brake motors,
motors with forced ventilation, with return stop or encoder, special sealing, etc. As a detailed measurement of
all possible combinations of designs features is hardly
practicable and in many cases unnecessary from a technical point of view, it is agreed to indicate for all these
special designs only the efficiency of the basic motor.
In addition the classification of motors for operation in
explosive atmospheres (EN 60079-0 und EN 61241-0)
will be possible in the future, too.
• Standard methods for determining losses and
efficiency from tests
(IEC 60034-2-1:2007 and DIN EN 60034-2-1:2008)
• Efficiency classes of single-speed, three-phase,
cage induction motors (IEC 60034-30)
The procedure is exceeding the present Voluntary
Agreement. At present we are expecting that the
standard IEC 60034-30 will become valid in the middle
of 2009. Than the following classification will be
mandatory:
Efficiency classes
Super-Premium
Premium
High
Standard
Below Standard Efficiency
Code
IEC 60034-30
IE4 *)
IE3
IE2
IE1
Not applicable in the future
EFF Code,
Voluntary Agreement of CEMEP
NEMA
–
EFF1
EFF2
EFF3
Premium
EPAct
Energy saving motors | Special catalogue 02-2009
*) only as information according to IEC TS 60034-31 Ed. 1
6
It is important to note that not only the efficiency classes, but also the test procedures were restructured. In
the new standard IEC 60034-2-1:2008 the former summation of losses method with a constant additional loss
of 0.5% in relation to the total input power is exchanged
with a procedure where the additional losses will be
determined individually. This is valid for asynchronous
motors from 1.1 kW.
The following procedures are permitted:
Motors in IE1 design
Summation of losses method corresponding with
EH-star-method, measurement uncertainty “medium”
(not in operation at VEM)
Motors in IE1, IE2 or IE3 design
≤ 1 kW unchanged, direct measurement,
measurement uncertainty „low”
1,1 kW to 150 kW summation of losses method and
(in line with IEEE 112/USA) addition loss determination
according to residual loss method, measurement uncertainty “low”.
This method is also used for the power range up to
375 kW in line with IEEE 112.
Introduction
Documentation
The applied method has to be cited in the documentation. The efficiency values resulting from application of the
residual loss method are lower than the values from the
presently used method. Therefore the limit values were
adjusted to the changed test methodology.
1
Figure 1: Shift of the limits by change of the selected test method, example 4-pole, 50 Hz
The identification is located on the name plate instead of
the EFF logo. Besides the efficiency class the rated efficiency of the motor will be printed on the name plate.
After implementation of this law, the manufacturer guarantees with the CE mark that the required rated efficiencies will be met and that the efficiencies printed on the
name plate are kept.
IE x – rated efficiency %, example: IE2-94.0%
In addition to the classification process the committees
of the European Union work for some time on implementing the EuP directive (“Ecodesign requirements for energy-using products” directive 2005/32/EG). This directive
establishes requirements for environmentally sound
design of energy-driven products and is therefore an
important activity in the direction of CO2 emission reduction. The content is mainly directed at energy-driven
consumer products. However electric drive systems are
also included.
The EuP framework directive has been published on
22.07.2005 in the official journal of the European
Communities and should be implemented in the member
states until 11.08.2007. This has been done in Germany
by introducing the “Energiebetriebene-Produkte-Gesetz”
(EBPG) (law for energy-driven products). The law about
the environmentally sound design of energy-driven products (“Gesetz über die umweltgerechte Gestaltung
energiebetriebener Produkte”) has become effective
on 07.03.2008. The implementation of the draft law is
supervised by the Federal Ministry of Economics and
Technology (Bundesministerium für Wirtschaft und
Technologie, BMWi). At the moment they are developing
actively the implementation rules. The introduction of
mandatory binding
minimum efficiencies (MEPS: Minimum Efficiency
Performance Requirements) for
IE 2 starting from 2012 and for
IE 3 (for output more than > 7,5 kW) starting from 2018
is intended.
After this effective date it is no longer allowed to place
IE1 motors on the market within the EU.
The market surveillance shall be done by third parties
to ensure that only motors with the statutory efficiencies
are placed on the market. For the manufacturers this
means a disproportionally high capital and cost expenditure for new motor development and test, for the introduction of new production processes, for acquisition
and installation of new production equipment and last
but not least this means an increased material usage.
Depending on the power range of the manufacturer the
costs for motors of efficiency class IE2 will rise about
15...30% compared with IE1. When looking at the transition to efficiency class IE3 the costs will rise yet again
about 15...30%.
With the introduction of the minimum efficiency classes
IE2 and IE3 the motor specifications of EN 50347 for a
correlation between shaft height and foot dimensions
can be kept only under certain conditions. Concerning
the length and the shaft size it can be said that the new
IE3 motor design might be significantly bigger compared
with current motors. This results not only in increased
prices due to material price additions compared to IE2
motors, but there will also be remarkable problems in
exchanging used motors, especially in applications
where today huge warehouses with spare motors exist
to enable quick access to spare parts and fast reaction
times in emergencies. In addition it must be noted that
the weight of the rotor and therefore the centrifugal
mass will be significantly bigger for IE2 and IE3 motors
compared to standard motors (IE1). This leads to a reduced permissible no load starting frequency and the
starting losses increase.
Energy saving motors | Special catalogue 02-2009
The identification of the used test method according to
DIN EN 60034-2-1:2008 is given in the installation, operating and maintenance manual attached to each motor.
7
Introduction
Energy efficient motors, especially of efficiency class
IE3, are therefore not suitable for applications with
frequent, very dynamic speed changes (Start/Stop
operation, S3, S4, etc.).
For that reason the CEMEP in its position as representative of the European motor manufacturers is rejecting the
introduction of a mandatory efficiency regulation (MEPS)
for motors of efficiency class IE3. CEMEP holds the view
that the market introduction of IE3 motors shall be done
based on a voluntary agreement with an accompanying
monitoring. It is the opinion of the manufacturers that
it is preferable to recommend the considerably more
effective system approach with variable speed drives to
reduce the energy consumption. This approach offers
significantly bigger energy savings and better results in
emission reduction.
VEM motors will at first start to offer standard motors
of the efficiency classes IE1 and IE2 according to IEC
60034-30 on the market. Thus we will also cover the
former efficiency classes EFF2 and EFF1.
The following design versions will be concerned or
excluded:
Product range
Three-phase asynchronous motors 0.75 … 375 kW, 2-, 4-, 6-pole
IP4X, 5X, 6X, cont. operation S1
Standard motors with mountings gear, separately driven fan,
brake, return stop, tachometer, encoder, …
Explosion-protected motors Ex nA, Ex tD A22
Explosion-protected motors Ex e II, Ex tD A21
Motors for short-time operation (S2) or intermittent operation (S3, S4…)
Pole-changing motors
Non-ventilated motors
Motors for inverter operation K2.., KU.., KV.., W2.., WU.., WV..
Compact drives
Motors with slip-ring rotors
Exhaust gas motors
Roller table motors
Permanent magnet motors
Water-cooled motors
Energy saving motors | Special catalogue 02-2009
Premium motors (IE3) are currently in the preparatory
stage and will be introduced to production as special
design motors at the end of 2009.
8
Please note:
Our policy is one of constant product improvement.
Design, technical data and illustrations are subject to
changes. They are not binding until confirmed in writing
by supplier’s works.
Efficiency classification
acc. to IEC 60034-30
marking starting from 01.04.2009
marking starting from 01.04.2009
(measurement without mountings)
marking starting from 01.04.2009
at the moment no marking
no marking
no marking
no marking
no marking
no marking
no marking
no marking
no marking
no marking
no marking
At VEM the main attention will be focused on the new
development of the IE2 series. This series shall replace
the current standard series K21R as basic series.
Technical explanations
Technical data
The performance data can be taken from the motor selection data tables.
Further important information for the selection of
three-phase asynchronous motors can be found in the
main catalogue of VEM “Low-voltage asynchronous
motors, IEC squirrel-cage motors”.
When the application of the motor requires additional
regulations, like gas or dust explosion protection, the
corresponding motor series must be used.
Standards and regulations
The motors comply with the relevant standards and regulations, particularly with the following:
Title
Rotating electrical machines, rating and performance
EN/DIN VDE
EN 60034-1
Efficiency classes of three-phase asynchronous motors
Rotating electrical machines
Standard methods for determining losses and efficiency from tests
Three-phase asynchronous motors for general use, with
standardised dimensions and outputs, frame sizes 56 – 315
Terminal markings and direction of rotation for rotating electrical machines
Rotating electrical machines
symbols for types of construction and erection
Built-in thermal protection
Rotating electrical machines, methods of cooling
Rotating electrical machines, degrees of protection
Rotating electrical machines, mechanical vibration
Rotating electrical machines, noise limits
Rotating electrical machines, starting performance of induction
cage motors up to 660 V, 50 Hz
IEC standard voltages
DIN EN 60034-2-1
IEC
IEC 60034-1
IEC 60085
IEC 60034-30
IEC 60034-2-1
EN 50347
IEC 60072
EN 60034-8
EN 60034-7
IEC 60034-8
IEC 60034-7
–
EN
EN
EN
EN
EN
IEC
IEC
IEC
IEC
IEC
IEC
60034-6
60034-5
60034-14
60034-9
60034-12
–
1
60034-11
60034-6
60034-5
60034-14
60034-9
60034-12
IEC 60038
VEM motors conform furthermore to various foreign regulations which are aligned to IEC 60034-1
or else have taken over the latter’s stipulations as European standard EN 60034-1.
Dimensions and types of construction
The motors are available in the types of construction IM B3, IM B5, IM B14, IM B35, IM B34 and
derived types taking into account the restrictions for the basic version.
Name plate
Examples for name plate with new IE mark
For motors with relubrication device the amount of
grease/lubrication process is additionally given on the
name plate or is noted on an auxiliary plate.
The name plates are fixed undetachably on the housing
with groove pins. They are available in aluminium or
stainless steel (additional charge).
If additional plates are required, please contact the
manufacturer.
Energy saving motors | Special catalogue 02-2009
As standard the motor name plate is designed in German/
English language for the standard series. Other languages are available on request. However for languages
from non-EC countries we ask for an additional charge.
On the name plate the rated values like type designation
and motor number, output, rated voltage and rated frequency, rated current, type of construction, type of protection, power factor, speed and thermal class are given.
The information can vary depending on the motor type.
9
Technical explanations
Type designation, VEM energy saving motors
Example: IE1-K21R 132 SX2-X
Energy saving motors | Special catalogue 02-2009
IE1
1
10
-
K
2
2
3
1
4
R
5
132
6
S
7
X
8
2
9
-
X
10
1
Efficiency class acc. to IEC 60034-30
IE1 …
IE2 …
2
Design version
K … squirrel-cage motor
W … energy saving motor
3
Design condition/generation
1 … series K1.
2 … series K2.
4
Characteristic number for standard
0 … IEC, progressive design series
1 … DIN/IEC
4 … DIN, special design variations
5
Type
R ...
O ...
F ...
6
Shaft height in mm
56, 63, 71, 80, 90, 100, 112, 132, 160, 180, 200, 225, 250, 280, 315, 355, 400
7
Foot length
K ... small
G ... large
S ... short
M ... medium
L ... long
8
Symbols for different output
X, Y, Z ...
9
Pole number
2, 4, 6, ... pole-changing separated by dashes
10
Special symbols
X … additional options
of cooling
fin cooled, IC 411
non-ventilated, IC 410
with forced ventilation, IC 416
Technical explanations
Fits: Shaft ends
Shaft ends
up to Ø 48
as of Ø 55
Mating components
k6
m6
H7
Tolerances – Electrical parameters
The following tolerances are permitted as specified in DIN EN 60034-1:
Efficiency (when determined indirectly)
Power factor
Slip
(at standard load in warmed-up state)
Starting current
(in the planned starting connection)
Starting torque
Pull-up torque
Pull-out torque
Moment of inertia
Noise level (Measurement area – sound intensity level)
Taking necessary manufacturing tolerances and deviations in materials in the case of the raw materials used
into account, these tolerances are permitted for threephase asynchronous motors. The following remarks are
given in the standard:
1. A guarantee of all or any of the values as specified
in the table is not mandatory. Guaranteed values to
which the permissible deviations should apply must
be specified expressly in tenders. The permissible
deviations must comply with the table.
- 0.15 (1-η) for PN ≤ 150 kW
- 0.1 (1-η) for PN > 150 kW
1-cosϕ
at least 0.02
6
at most 0.07
± 20 % for PN ≥ 1 kW
± 30 % for PN < 1 kW
+ 20 %
without lower limit
- 15 % and + 25 %
- 15 %
- 10 % (after application of this tolerance
MK/M still at least 1.6)
± 10 %
+ 3 dB (A)
1
2. Attention is drawn to the differences in the interpretation of the concept of a “guarantee”. In some
countries, there is a differentiation between typical
and declared values.
3. If a permissible deviation only applies in one direction,
the value will not be limited in the other direction
Tolerances – Mechanical parameters
Spacing of feet fixing holes in axial direction
Diameter or width across corners of flange
Spacing of feet fixing holes across axial direction
Diameter of centring flange
D, DA [d, d1]
Diameter of the cylindrical shaft end
M [e1]
AB [f], AC [g]
H [h]
Pitch circle diameter of the mounting flange
Largest width of the motor (without terminal boxes)
Shaft height (lowest edge of foot to centre of shaft end)
L, LC [k, k1]
HD [p]
K, K’ [s, s1]
GA, GC [t, t1]
F, FA [u, u1]
C, CA [w1, w2]
Total length of the motor
Total height of the motor (lowest edge of foot)
Diameter of the mounting holes of the foot or flange
Lowest edge of shaft end to the upper edge of the key
Width of the key
Distance from the centre of the first foot mounting hole
to the shaft shoulder or flange face
Distance from the shaft shoulder to the flange face in
the case of fixed bearing on D-end
Distance from the shaft shoulder to the flange face
Motor mass
m
Meaning of the dimension
Fit or tolerance
± 1 mm
- 1 mm
± 1 mm
up to diameter 230 mm j6
from diameter 250 mm h6
up to diameter 48 mm k6
from diameter 55 mm m6
± 0.8 mm
+2%
up to 250 - 0.5 mm
above 250 -1 mm
+1%
+2%
+3%
+ 0.2 mm
h9
± 3 mm
± 0.5 mm
± 3 mm
- 5 bis +10 %
Energy saving motors | Special catalogue 02-2009
Letter codes
acc. to DIN EN 50347
B [a]
P [a1]
A [b]
N [b1]
11
Efficiency limits
Minimum efficiencies for
energy saving motors in design “Standard Efficiency”
Power
PB
[kW]
IEC
IE1
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
[150]
160
[175]
200
250
315
355
72.1
75
77.2
79.7
81.5
83.1
84.7
86
87.6
88.7
89.3
89.9
90.7
91.2
91.7
92.1
92.7
93
93.3
93.5
93.8
94
94
94
94
CEMEP
China
EFF2
Grade 3
3000 rpm – 2-pole
76.2
78.5
81
82.6
84.2
85.7
87
88.4
89.4
90
90.5
91.4
92
92.5
93
93.6
93.9
-
75
76.2
78.5
81
82.6
84.2
85.7
87
88.4
89.4
90
90.5
91.4
92
92.5
93
93.6
93.9
94
94.5
94.6
94.8
95.2
95.4
95.4
IEC
IE1
CEMEP
China
EFF2
Grade 3
1500 rpm – 4-pole
72.1
75
77.2
79.7
81.5
83.1
84.7
86
87.6
88.7
89.3
89.9
90.7
91.2
91.7
92.1
92.7
93
93.3
93.5
93.8
94
94
94
94
Explanation of terms:
Energy saving motors | Special catalogue 02-2009
IE1
EFF2
Grade 3
12
Code acc. to IEC 60034-30
Efficiency class according to the Voluntary Agreement of CEMEP in Europe
“Energy efficiency” acc. to GB 18613-2006, China
76.2
78.5
81
82.6
84.2
85.7
87
88.4
89.4
90
90.5
91.4
92
92.5
93
93.6
93.9
-
71
73
76.2
78.5
81
82.6
84.2
85.7
87
88.4
89.4
90
90.5
91.4
92
92.5
93
93.6
93.9
94.5
94.8
94.9
94.9
95.2
95.2
95.2
IEC
China
IE1
Grade 3
1000 rpm – 6-pole
70
72.9
75.2
77.7
79.7
81.4
83.1
84.7
86.4
87.7
88.6
89.2
90.2
90.8
91.4
91.9
92.6
92.9
93.3
93.5
93.8
94
94
94
94
65
69
72
76
79
81
82
84
86
87.5
89
90
90
91.5
92
92.5
92.8
93.5
93.8
94
94.2
94.5
94.5
94.5
-
Efficiency limits
Minimum efficiencies for
energy saving motors in design “High Efficiency”
Power
PB
[kW]
IEC
IE2
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
[150]
160
[175]
200
250
315
355
77.4
79.6
81.3
83.2
84.6
85.8
87
88.1
89.4
90.3
90.9
91.3
92
92.5
92.9
93.2
93.8
94.1
94.3
94.6
94.8
95
95
95
95
CEMEP
EPAct*
EFF1
3000 rpm – 2-pole
82.8
84.1
85.6
86.7
87.6
88.6
89.5
90.5
91.3
91.8
92.2
92.9
93.3
93.7
94
94.6
95
-
75.5
82.5
84
85.5
87.5
87.5
88.5
89.5
90.2
90.2
91
91
91.7
92.4
93
93
93.6
94.5
94.5
95
-
China
Grade 2
IEC
IE2
82.8
84.1
85.6
85.6
86.7
87.6
88.6
89.5
90.5
91.3
91.8
92.2
92.9
93.3
93.7
94
94.6
95
95
95.4
95.4
95.4
95.8
95.8
95.8
79.6
81.4
82.8
84.3
85.5
86.6
87.7
88.7
89.8
90.6
91.2
91.6
92.3
92.7
93.1
93.5
94
94.2
94.5
94.7
94.9
95.1
95.1
95.1
95.1
CEMEP
EPAct*
EFF1
1500 rpm – 4-pole
83.8
85
86.4
87.4
88.3
89.2
90.1
91
91.8
92.2
92.6
93.2
93.6
93.9
94.2
94.7
95
-
82.5
84
84
87.5
87.5
87.5
89.5
89.5
91
91
92.4
92.4
93
93
93.6
94.1
94.5
94.5
95
95
-
China
Grade 2
80.7
82.3
85
85
86.4
87.4
88.3
89.2
90.1
91
91.8
92.2
92.6
93.2
93.6
93.9
94.2
94.7
95
95.4
95.4
95.4
95.4
95.8
95.8
95.8
IEC
EPAct*
China
IE2
Grade 2
1000 rpm – 6-pole
75.9
78.1
79.8
81.8
83.3
84.6
86
87.2
88.7
89.7
90.4
90.9
91.7
92.2
92.7
93.1
93.7
94
94.3
94.6
94.8
95
95
95
95
80
85.5
86.5
87.5
87.5
87.5
89.5
89.5
90.2
90.2
91.7
91.7
93
93
93.6
93.6
94.1
94.1
95
95
-
75.4
77.7
79.9
81.5
83.4
84.9
86.1
87.4
89
90
91
91.5
92
92.5
93
93.5
93.8
94.2
94.5
95
95
95
95
95
-
1
Explanation of terms:
Code acc. to IEC 60034-30
Efficiency class according to the Voluntary Agreement of CEMEP in Europe
“Energy efficiency” acc. to GB 18613-2006, China
“High Efficiency” acc. to NEMA MG1 and CSA C390, values only applicable for 60 Hz
Energy saving motors | Special catalogue 02-2009
IE2
EFF1
Grade 2
EPAct
13
Energy saving motors | Special catalogue 02-2009
Energy saving motors, Standard efficiency IE1
14
Energy saving motors, Standard efficiency IE1
Energy saving motors, Standard efficiency IE1
Basic version
General technical data
Energy saving motors | Special catalogue 02-2009
Motor selection data
50 Hz, 2- up to 8-pole
3000/1500/1000/750 rpm
16
Energy saving motors, Standard efficiency IE1
General technical data
The most important technical data is summarized in the following table.
Detailed information can be found in the catalogue part “Technical explanations”.
Type of protection
Type of cooling
Coolant temperature/
altitude of site
Rated voltage
Efficiency
Types of construction
Colour system
Vibration grade
Shaft end
Sound pressure level
Limit speeds
Bearing design
Motor weights
Terminal boxes
Documentation
Tolerances
Options
Motor with squirrel-cage rotor, IEC/DIN
0.06 kW to 500 kW
56 to 355
Grey cast iron
0.30 Nm to 3600 Nm
Motors with one speed are designed with Δ/Y-circuit as standard.
Thermal class 155, as option 155 [F(B)], 180
acc. to EN 60034-1 (IEC 60034-1)
IP 55 acc. to EN 60034-5 (IEC 60034-5), as option IP 56 and higher
IC 411 acc. to EN 60034-6 (IEC 60034-6)
As standard - 20°C up to + 40°C,
altitude of site 1000 m above sea level
Rated voltage ranges A and B
acc. to EN 60034-1 (IEC 60034-1),
standard voltage acc. to EN 60038
50 Hz, 230 V, 400 V, 500 V and 690 V
according to EN 60034-2-1; ≤ 1 kW direct measurement; 1.1 kW up to
150 kW summation of losses and (in line with USA, IEEE 112) additional
loss determination according to additional loss method. This method is also
used for the power range up to 375 kW corresponding with IEEE 112.
IM B3, IM B35, IM B5 and derived types of construction
acc. to EN 60034-7
Standard colour system “moderate”, colour shade RAL 7031, blue-grey
Special colour system “world wide”, colour shade RAL 7031, blue-grey
As standard grade “A” for motors without special vibration requirements
Acc. to DIN 748 (IEC 60072), balancing “with half key”
Acc. to EN ISO 1680, tolerance +3dB,
data see in the main catalogue 01-2008 part “Technical explanations”
Please refer to paragraph about limit speeds
in the main catalogue 01-2008 part “Technical explanations”.
Please refer to paragraph about bearings
in the main catalogue 01-2008 part “Technical explanations”.
Please refer to the technical selection lists.
Please refer to paragraph about terminal boxes
in the main catalogue 01-2008 part “Technical explanations”.
An operation and maintenance manual, a connection diagram and
a safety data sheet is attached to each motor.
Please refer to paragraph about tolerances
in the main catalogue 01-2008 part “Technical explanations”.
Please refer to paragraph about modifications
in the main catalogue 01-2008 part “Technical explanations”.
2
Energy saving motors | Special catalogue 02-2009
Product line
Rated output
Sizes
Material of housing
Rated torque
Types of circuit
Insulation of stator winding
17
Energy saving motors, Standard efficiency IE1
Three-phase motors with squirrel-cage rotor
with surface ventilation, mode of operation S1, continuous duty
thermal class 155, degree of protection IP 55
Motor selection data
Design point 400 V, 50 Hz
Type
PB
MB
nB
kW
Nm
IE class
IB
η4/4
400 V
EN 60034-2-1
rpm
- %
A
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
110
132
160
200
250
315
315
355
400
450
500
0.30
0.41
0.62
0.85
1.27
1.89
2.54
3.71
5.04
7.37
10.0
13.2
18.2
24.9
18.4
24.7
36.2
48.9
60.5
71.6
97.5
120
146
178
241
289
353
424
514
643
803
1011
1007
1138
1280
1441
1560
2840
2830
2790
2800
2780
2775
2825
2835
2840
2850
2865
2900
2890
2880
2860
2900
2900
2930
2920
2935
2940
2940
2940
2955
2970
2970
2975
2975
2975
2970
2973
2980
2988
2980
2985
2983
2985
IA/IB
cos ϕB
-
-
-
EFF class
η4/4
η3/4
EN 60034-2
%
%
4.9
4.5
4.1
4.2
4.4
5.1
5.9
6.0
7.0
7.5
6.8
7.0
7.5
6.3
5.5
6.6
7.0
7.1
7.2
6.8
7.3
7.0
7.5
7.5
7.5
8.5
8.5
8.5
8.5
8.2
7.3
8.6
8.6
7.3
8.5
7.2
8.2
0.74
0.77
0.76
0.72
0.79
0.81
0.81
0.80
0.86
0.85
0.84
0.81
0.84
0.84
0.86
0.86
0.90
0.90
0.92
0.92
0.92
0.90
0.91
0.91
0.92
0.91
0.91
0.91
0.93
0.92
0.93
0.92
0.88
0.91
0.90
0.92
0.92
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
2
1
2
-
70.0
70.3
67.1
68.1
71.5
74.3
77.5
77.8
81.2
82.0
83.4
85.0
86.3
87.0
85.7
87.0
88.5
89.4
90.5
91.8
92.8
93.0
93.7
93.7
94.6
94.7
95.4
95.4
96.0
96.0
96.1
96.7
96.8
96.5
96.8
96.9
97.2
EFF-
MA/MB MS/MB MK/MB
J
m
-
-
-
kgm2
kg
2.3
2.1
1.9
2.2
2.1
2.3
2.4
2.4
2.5
2.8
2.4
2.2
2.4
1.5
1.8
1.8
2.4
2.2
2.1
1.7
2.0
1.8
1.8
2.0
2.0
2.2
1.5
2.0
2.0
2.6
2.1
2.7
1.3
1.3
1.9
1.3
1.8
2.3
2.1
1.9
2.2
2.1
2.1
2.4
2.3
2.5
2.3
2.2
2.1
2.2
1.2
1.6
1.3
2.0
1.7
1.6
1.4
1.6
1.3
1.4
1.5
1.6
1.8
1.3
1.8
1.6
2.0
1.4
1.7
1.0
1.0
1.3
1.0
0.9
2.8
2.3
2.2
2.4
2.3
2.6
2.4
2.6
2.8
2.9
2.8
2.9
3.0
2.6
2.2
2.5
3.0
2.9
2.8
2.6
2.9
2.4
2.7
2.6
2.6
2.8
2.5
2.7
2.6
2.6
2.0
2.4
3.0
2.3
3.2
2.4
2.6
0.00013
0.00013
0.00013
0.00015
0.00025
0.00032
0.00057
0.00072
0.00132
0.0017
0.00275
0.0045
0.0055
0.0680
0.0081
0.0110
0.0258
0.0575
0.0675
0.105
0.128
0.193
0.220
0.375
0.650
0.675
1.21
1.44
1.76
2.82
3.66
4.43
4.1
4.2
5.5
7.1
7.1
4.4
4.5
4.9
5.2
6.7
7.6
10.7
11.5
16
19
25
32
40
48
52
57
81
118
134
165
195
255
290
360
490
510
720
800
980
1170
1460
1630
1900
2000
2200
2400
2400
Synchronous speed 3000 rpm – 2-pole version
Energy saving motors | Special catalogue 02-2009
K21O 56 K2 U
K21R 56 G2
K21R 63 K2
K21R 63 G2
K21R 71 K2
K21R 71 G2
IE1-K21R 80 K2
IE1-K21R 80 G2
IE1-K21R 90 S2
IE1-K21R 90 L2
IE1-K21R 100 L2
IE1-K21R 112 M2
IE1-K21R 132 S2 T
IE1-K21R 132 SX2 T
IE1-K21R 132 S2
IE1-K21R 132 SX2
IE1-K21R 160 M2
IE1-K21R 160 MX2
IE1-K21R 160 L2
IE1-K21R 180 M2
IE1-K21R 200 L2
IE1-K21R 200 LX2
IE1-K21R 225 M2
IE1-K21R 250 M2
IE1-K21R 280 S2
IE1-K21R 280 M2
IE1-K21R 315 S2
IE1-K21R 315 M2
IE1-K21R 315 MX2
IE1-K21R 315 MY2
IE1-K21R 315 L2
IE1-K21R 315 LX2
IE1-K22R 355 MY2
IE1-K22R 355 M2
K22R 355 MX2
K22R 355 LY2
K22R 355 L2
18
K20R 56 K2
K20R 56 G2
K20R 63 K2
K20R 63 G2
IE1-K20R 71 K2
IE1-K20R 71 G2
IE1-K20R 80 K2
IE1-K20R 80 G2
IE1-K20R 90 L2
IE1-K20R 100 S2
IE1-K20R 100 L2
IE1-K20R 100 LV2
IE1-K20R 112 M2
IE1-K20R 132 M2
IE1-K20R 160 S2
IE1-K20R 160 M2
IE1-K20R 180 S2
IE1-K20R 180 M2
IE1-K20R 200 M2
IE1-K20R 200 L2
IE1-K20R 225 M2
IE1-K20R 250 S2
IE1-K20R 250 M2
IE1-K20R 280 S2
IE1-K20R 280 M2
IE1-K20R 315 S2
IE1-K20R 315 M2
IE1-K20R 315 L2
IE1-K20R 315 LX2
IE1-76.8
IE1-76.9
IE1-81.2
IE1-82.1
IE1-82.8
IE1-84.9
IE1-85.9
IE1-87.1
IE1-84.7
IE1-86.0
IE1-87.6
IE1-88.7
IE1-89.3
IE1-89.9
IE1-91.1
IE1-91.5
IE1-92.0
IE1-92.2
IE1-93.1
IE1-93.2
IE1-93.5
IE1-93.8
IE1-94.0
IE1-94.0
IE1-94.1
IE1-94.5
IE1-94.5
IE1-94.3
-
0.25
0.32
0.51
0.74
0.94
1.32
1.72
2.55
3.10
4.55
6.15
8.40
11.0
14.8
11.0
14.5
20.0
27.0
32.0
37.5
50.5
64
76
93
124
151
183
219
259
327
404
511
534
583
663
729
807
67.5
69.6
63.1
65.6
69.7
72.7
77.3
77.4
80.2
81.5
84.2
86.3
86.6
88.0
85.7
87.0
88.5
89.4
89.5
91.0
92.0
92.0
93.0
92.5
93.5
94.2
94.5
94.5
95.0
95.2
95.2
96.7
96.6
96.5
96.7
96.7
97
Energy saving motors, Standard efficiency IE1
Three-phase motors with squirrel-cage rotor
with surface ventilation, mode of operation S1, continuous duty
thermal class 155, degree of protection IP 55
Motor selection data
Design point 400 V, 50 Hz
Type
PB
MB
nB
kW
Nm
IE class
IB
η4/4
400 V
EN 60034-2-1
rpm
- %
A
0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
110
132
160
200
250
315
315
355
400
450
500
0.41
0.63
0.84
1.26
1.72
2.58
3.75
5.12
7.45
10.2
14.9
20.0
26.6
36.9
36.5
49.4
72.5
97.8
121
143
196
240
292
356
484
581
707
849
1032
1286
1608
2019
2016
2275
2557
2884
3205
1410
1375
1370
1360
1385
1370
1400
1400
1410
1400
1410
1430
1435
1425
1440
1450
1450
1465
1460
1465
1465
1470
1470
1475
1480
1480
1485
1485
1480
1485
1485
1490
1492
1490
1494
1490
1490
IA/IB
cos ϕB
-
-
-
EFF class
η4/4
η3/4
EN 60034-2
%
%
3.1
3.2
3.2
3.3
3.6
3.8
4.1
4.6
5.5
5.5
6.0
6.5
6.9
6.3
6.5
6.0
6.8
7.3
6.8
6.5
7.0
7.0
7.0
7.0
7.0
7.0
7.5
7.0
7.0
7.5
8.0
8.6
7.1
8.1
8.6
8.0
7.9
0.60
0.68
0.68
0.66
0.72
0.74
0.69
0.70
0.79
0.81
0.79
0.79
0.78
0.78
0.89
0.84
0.85
0.86
0.86
0.84
0.85
0.86
0.86
0.86
0.86
0.86
0.86
0.86
0.87
0.88
0.90
0.88
0.85
0.84
0.84
0.82
0.79
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
-
60.5
62.0
57.5
61.0
64.6
67.8
71.5
73.5
76.6
78.8
81.2
82.6
84.2
86.3
85.7
87.0
88.4
89.4
90.0
90.5
91.5
92.5
93.0
93.5
94.1
94.6
95.1
95.1
95.0
96.0
96.1
96.5
95.6
96.8
96.8
96.8
96.7
EFF-
MA/MB MS/MB MK/MB
J
m
-
-
-
kgm2
kg
2.3
1.9
1.9
2.0
1.8
2.0
2.1
2.2
2.3
2.5
2.5
2.5
2.6
2.5
1.9
2.0
2.2
2.5
2.5
2.0
2.0
2.0
2.0
2.2
2.0
2.1
1.8
1.8
1.8
2.0
2.0
1.9
1.4
1.8
1.3
1.2
1.1
2.3
1.9
1.8
2.0
1.8
2.0
2.0
2.1
2.2
2.4
2.3
2.2
2.5
2.4
1.7
1.7
1.9
2.0
2.0
1.8
1.7
1.7
1.7
1.7
1.7
1.6
1.6
1.5
1.5
1.8
1.6
1.5
1.0
1.0
1.0
1.0
1.0
2.7
2.2
2.2
2.3
2.1
2.2
2.3
2.3
2.5
2.6
2.7
2.9
3.2
2.9
3.0
2.9
3.3
3.0
2.9
2.6
2.4
2.5
2.5
2.3
2.2
2.2
2.2
2.2
2.0
2.4
2.3
2.5
2.9
3.1
3.0
3.0
3.0
0.00019
0.00019
0.00019
0.00024
0.00040
0.00050
0.00087
0.00107
0.00207
0.00260
0.00400
0.00725
0.009
0.011
0.015
0.028
0.035
0.078
0.090
0.138
0.168
0.275
0.313
0.525
0.950
1.10
1.96
2.27
2.73
4.82
5.93
6.82
5.6
7.9
9.5
10
10
4.3
4.4
4.8
5.2
6.8
7.8
10.6
11.7
15.5
18
23.5
30
37
47
50
70
92
120
136
170
220
270
300
375
520
580
740
840
1000
1200
1510
1630
1950
2150
2400
2500
2500
Synchronous speed 1500 rpm – 4-pole version
K20R 56 K4
K20R 56 G4
K20R 63 K4
K20R 63 G4
K20R 71 K4
IE1-K20R 71 G4
IE1-K20R 80 K4
IE1-K20R 80 G4
IE1-K20R 90 L4
IE1-K20R 100 S4
IE1-K20R 100 L4
IE1-K20R 100 LX4
IE1-K20R 112 M4
IE1-K20R 132 S4
IE1-K20R 132 M4
IE1-K20R 160 S4
IE1-K20R 160 M4
IE1-K20R 180 S4
IE1-K20R 180 M4
IE1-K20R 200 M4
IE1-K20R 200 L4
IE1-K20R 225 M4
IE1-K20R 250 S4
IE1-K20R 250 M4
IE1-K20R 280 S4
IE1-K20R 280 M4
IE1-K20R 315 S4
IE1-K20R 315 M4
IE1-K20R 315 L4
IE1-K20R 315 LX4
IE1-73.6
IE1-76.7
IE1-78.6
IE1-80.2
IE1-82.4
IE1-84.1
IE1-85.2
IE1-84.9
IE1-86.5
IE1-88.0
IE1-88.7
IE1-89.3
IE1-89.9
IE1-90.7
IE1-91.2
IE1-91.7
IE1-92.3
IE1-92.7
IE1-93.3
IE1-93.5
IE1-93.5
IE1-93.8
IE1-94.3
IE1-94.3
IE1-94.5
IE1-94.0
IE1-94.5
-
0.24
0.31
0.44
0.65
0.78
1.06
1.60
2.10
2.62
3.40
4.95
6.65
8.8
11.8
10.5
15.0
21.0
28.0
34.5
42.0
55.5
67.0
81.0
98.5
134
160
194
233
279
342
417
535
560
630
710
818
945
56.8
61.0
56.7
56.5
62.3
66.9
69.3
70.8
75.3
77.9
82.0
82.6
83.6
85.3
85.7
86.0
88.0
89.0
89.5
90.5
91.0
91.5
92.5
93.0
93.5
93.5
94.5
94.5
94.8
95.0
95.0
95.5
95.5
96.5
96.7
96.7
96.4
2
Energy saving motors | Special catalogue 02-2009
K21O 56 K4 U
K21R 56 G4
K21R 63 K4
K21R 63 G4
K21R 71 K4
K21R 71 G4
K21R 80 K4
IE1-K21R 80 G4
IE1-K21R 90 S4
IE1-K21R 90 L4
IE1-K21R 100 L4
IE1-K21R 100 LX4
IE1-K21R 112 M4
IE1-K21R 132 S4 T
IE1-K21R 132 S4
IE1-K21R 132 M4
IE1-K21R 160 M4
IE1-K21R 160 L4
IE1-K21R 180 M4
IE1-K21R 180 L4
IE1-K21R 200 L4
IE1-K21R 225 S4
IE1-K21R 225 M4
IE1-K21R 250 M4
IE1-K21R 280 S4
IE1-K21R 280 M4
IE1-K21R 315 S4
IE1-K21R 315 M4
IE1-K21R 315 MX4
IE1-K21R 315 MY4
IE1-K21R 315 L4
IE1-K21R 315 LX4
IE1-K22R 355 MY4
IE1-K22R 355 M4
K22R 355 MX4
K22R 355 LY4
K22R 355 L4
19
Energy saving motors, Standard efficiency IE1
Three-phase motors with squirrel-cage rotor
with surface ventilation, mode of operation S1, continuous duty
thermal class 155, degree of protection IP 55
Motor selection data
Design point 400 V, 50 Hz
Type
PB
MB
kW
Nm
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
110
132
160
200
200
250
315
355
0.96
1.30
1.86
2.61
3.86
5.74
7.66
11.24
15.16
22.12
30.6
30.0
40.0
55.0
74.6
109
148
182
217
294
362
439
536
727
868
1061
1273
1551
1929
1920
2402
3023
3407
nB
IE class
IB
η4/4
400 V
EN 60034-2-1
rpm
- %
A
IA/IB
cos ϕB
-
-
-
EFF class
η4/4
η3/4
EN 60034-2
%
%
895
880
925
915
915
915
935
935
945
950
935
955
955
955
960
965
965
970
970
973
975
980
980
985
990
990
990
985
990
995
994
995
995
2.5
2.5
2.8
2.9
3.4
3.7
4.5
4.6
4.6
5.3
5.2
5.7
6.0
5.0
5.5
5.0
6.0
5.5
6.2
6.5
6.5
6.0
6.5
7.0
7.0
7.5
7.5
7.5
8.3
7.0
7.0
6.8
7.4
0.56
0.56
0.51
0.55
0.66
0.67
0.64
0.69
0.73
0.74
0.75
0.82
0.80
0.83
0.82
0.86
0.83
0.87
0.87
0.89
0.89
0.87
0.88
0.87
0.88
0.88
0.88
0.89
0.87
0.83
0.81
0.83
0.78
-
50.5
52.0
58.0
60.0
66.0
68.0
70.0
73.0
76.4
79.8
81.9
78.5
80.0
83.0
85.0
85.2
86.0
88.1
88.8
90.4
91.0
92.0
92.5
93.7
94.4
94.0
95.0
95.3
95.0
96.1
96.0
96.5
96.0
EFF-
MA/MB MS/MB MK/MB
J
m
-
-
-
kgm2
kg
2.0
2.0
1.6
2.0
2.0
2.2
2.4
2.2
2.1
2.2
2.5
1.8
2.2
1.8
2.0
2.0
2.4
2.0
2.2
2.2
2.2
2.0
2.3
2.0
2.0
2.2
2.0
2.3
2.2
1.5
1.8
1.6
1.9
2.0
2.0
1.6
2.0
2.0
2.2
2.4
2.2
2.0
2.1
2.5
1.6
2.0
1.5
1.6
1.7
2.1
1.7
1.8
1.7
1.7
1.5
1.7
1.6
1.7
1.7
1.7
1.9
2.0
1.3
1.3
1.3
1.4
2.4
2.3
2.1
2.2
2.0
2.4
2.6
2.6
2.4
2.7
2.9
2.7
3.1
2.3
2.5
2.3
2.7
2.4
2.6
2.5
2.3
2.0
2.4
2.4
2.4
2.6
2.4
2.4
2.7
2.4
2.3
2.5
2.6
0.00024
0.00027
0.00045
0.00060
0.00130
0.00175
0.00325
0.00425
0.00625
0.01225
0.0139
0.0180
0.0230
0.0430
0.0530
0.113
0.145
0.228
0.268
0.443
0.825
1.28
1.48
2.63
3.33
3.60
6
6.67
8.6
8.1
8.2
12.1
14
4.9
5.7
7.4
8.3
11
12.5
16
19
24
33.5
39
46
53
70
86
114
136
175
200
265
360
465
520
690
800
880
1050
1250
1460
1550
1850
2200
2400
Synchronous speed 1000 rpm – 6-pole version
Energy saving motors | Special catalogue 02-2009
K21R 63 K6
K21R 63 G6
K21R 71 K6
K21R 71 G6
K21R 80 K6
K21R 80 G6
IE1-K21R 90 S6
IE1-K21R 90 L6
IE1-K21R 100 L6
IE1-K21R 112 M6
IE1-K21R 132 S6 T
IE1-K21R 132 S6
IE1-K21R 132 M6
IE1-K21R 132 MX6
IE1-K21R 160 M6
IE1-K21R 160 L6
IE1-K21R 180 L6
IE1-K21R 200 L6
IE1-K21R 200 LX6
IE1-K21R 225 M6
IE1-K21R 250 M6
IE1-K21R 280 S6
IE1-K21R 280 M6
IE1-K21R 315 S6
IE1-K21R 315 M6
IE1-K21R 315 MX6
IE1-K21R 315 MY6
IE1-K21R 315 L6
IE1-K21R 315 LX6
K22R 355 MY6
K22R 355 M6
K22R 355 MX6
K22R 355 LY6
20
K20R 56 K6
K20R 56 G6
K20R 63 K6
K20R 63 G6
K20R 71 K6
K20R 71 G6
IE1-K20R 80 K6
IE1-K20R 80 G6
IE1-K20R 90 L6
IE1-K20R 100 L6
IE1-K20R 100 LX6
IE1-K20R 112 M6
IE1-K20R 112 MX6
IE1-K20R 132 S6
IE1-K20R 132 M6
IE1-K20R 160 S6
IE1-K20R 160 M6
IE1-K20R 180 S6
IE1-K20R 180 M6
IE1-K20R 200 M6
IE1-K20R 225 M6
IE1-K20R 250 S6
IE1-K20R 250 M6
IE1-K20R 280 S6
IE1-K20R 280 M6
IE1-K20R 315 S6
IE1-K20R 315 M6
IE1-K20R 315 L6
IE1-K20R 315 LX6
IE1-70.5
IE1-73.4
IE1-76.0
IE1-78.1
IE1-81.9
IE1-79.7
IE1-81.4
IE1-83.3
IE1-85.0
IE1-86.4
IE1-87.7
IE1-88.6
IE1-89.2
IE1-90.2
IE1-90.8
IE1-91.4
IE1-91.9
IE1-92.7
IE1-93.4
IE1-93.3
IE1-94.0
IE1-94.3
IE1-94.2
IE1-94.4
IE1-94.5
IE1-94.5
IE1-94.4
0.46
0.59
0.88
1.10
1.22
1.73
2.4
3.18
3.90
5.35
7.05
6.7
9.0
11.5
15.5
21.5
30.5
35
41
54
66
81
97.5
133
156
192
228
272
349
362
464
568
684
45.3
48.0
54.5
56.5
62.5
65.5
67.5
70.0
76.2
78.9
82.4
78.5
79.0
83.0
84.0
85.0
85.0
88.0
88.5
90.0
90.8
92.0
92.0
93.0
93.5
93.8
94.7
95.0
94.7
96.0
95.7
96.5
95.8
Energy saving motors, Standard efficiency
Three-phase motors with squirrel-cage rotor
with surface ventilation, mode of operation S1, continuous duty
thermal class 155, degree of protection IP 55
Motor selection data
Design point 400 V, 50 Hz
Type
PB
MB
nB
IB
IA/IB
cos ϕB
kW
Nm
rpm
400 V
A
-
-
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
18.5
22
30
37
45
55
75
90
110
132
160
160
200
250
280
1.27
1.71
2.49
3.44
5.05
7.56
10.2
14.9
20.3
30.7
29.8
40.6
53.8
74.0
98.8
146
198
244
244
290
395
481
585
710
966
1161
1420
1704
2065
2054
2571
3209
3594
675
670
690
695
700
695
705
705
705
685
705
705
710
710
725
720
725
725
725
725
730
735
735
740
740
740
740
740
740
744
743
744
744
0.56
0.73
0.78
1.12
1.6
2.04
2.7
3.25
4.1
6.3
5.5
7.4
9.3
12.5
16.5
24
31.5
38
36
42.5
61
73.5
92
107
143
172
207
242
307
303
392
483
544
2.1
2.3
2.8
3.0
3.0
3.2
3.3
4.0
4.4
3.8
4.5
4.5
4.0
4.5
4.5
4.5
5.0
5.0
5.5
5.0
5.5
5.5
6.0
6.5
6.0
6.0
6.5
6.3
7.2
6.8
6.5
6.6
8.2
0.51
0.51
0.59
0.56
0.54
0.60
0.60
0.67
0.70
0.68
0.76
0.75
0.78
0.78
0.78
0.78
0.79
0.80
0.83
0.84
0.79
0.80
0.77
0.80
0.81
0.81
0.81
0.83
0.79
0.80
0.77
0.78
0.78
EN 60034-2
η3/4
η4/4
%
%
MA/MB
MS/MB
MK/MB
J
m
-
-
-
kgm2
kg
1.9
1.8
2.0
2.3
1.9
1.9
1.8
2.0
2.2
2.0
1.7
1.7
1.6
1.7
1.8
2.0
2.0
1.9
2.0
1.8
2.2
2.0
2.3
1.8
2.0
1.9
2.1
2.0
2.2
1.3
1.6
1.3
1.2
1.9
1.8
2.0
2.3
1.9
1.9
1.8
2.0
2.1
1.9
1.6
1.6
1.3
1.6
1.6
1.7
1.7
1.7
1.6
1.5
1.8
1.5
1.8
1.6
1.6
1.6
1.8
1.7
1.9
1.0
1.0
1.0
1.0
2.1
2.1
2.2
2.5
2.1
2.2
2.2
2.4
2.5
2.3
2.3
2.3
1.9
2.1
2.1
2.1
2.3
2.2
2.2
2.2
2.2
2.0
2.4
2.3
2.3
2.2
2.4
2.1
2.5
2.5
2.7
2.8
2.8
0.00050
0.00060
0.00130
0.00175
0.00300
0.00375
0.00625
0.00900
0.01225
0.01390
0.018
0.023
0.043
0.053
0.113
0.145
0.228
0.268
0.44
0.44
0.825
1.35
1.55
2.63
3.33
3.60
6
6.76
8.71
9.3
9.5
13.4
15.8
6.6
8.1
10.5
12
15
18
23
28
33.5
39
46
53
70
86
114
136
175
200
265
265
360
465
520
690
800
880
1100
1250
1430
1700
1850
2200
2400
Synchronous speed 750 rpm – 8-pole version
K21R 225 S8
K21R 225 M8
K21R 250 M8
K21R 280 S8
K21R 280 M8
K21R 315 S8
K21R 315 M8
K21R 315 MX8
K21R 315 MY8
K21R 315 L8
K21R 315 LX8
K22R 355 MY8
K22R 355 M8
K22R 355 MX8
K22R 355 LY8
K20R 63 K8
K20R 63 G8
K20R 71 K8
K20R 71 G8
K20R 80 K8
K20R 80 G8
K20R 90 L8
K20R 100 S8
K20R 100 L8
K20R 100 LX8
K20R 112 M8
K20R 112 MX8
K20R 132 S8
K20R 132 M8
K20R 160 S8
K20R 160 M8
K20R 180 S8
K20R 180 M8
K20R 200 M8
K20R 225 M8
K20R 250 S8
K20R 250 M8
K20R 280 S8
K20R 280 M8
K20R 315 S8
K20R 315 M8
K20R 315 L8
K20R 315 LX8
45.5
46.5
56.5
58.0
61.5
64.5
67.0
73.0
75.5
75.8
75.5
78.0
79.3
81.4
83.0
85.0
86.5
87.5
89.2
89.2
90.2
91.0
91.5
93.1
93.3
93.5
94.6
95.0
95.2
95.2
95.6
95.8
95.3
40.3
41.3
53.8
54.0
56.3
61.8
64.0
72.5
75.3
75.9
75.0
78.0
79.0
81.0
83.0
84.0
86.0
86.5
88.0
89.0
90.0
90.5
91.0
92.0
93.0
93.0
94.0
94.3
94.5
95.0
95.3
95.6
95.1
2
Energy saving motors | Special catalogue 02-2009
K21R 71 K8
K21R 71 G8
K21R 80 K8
K21R 80 G8
K21R 90 S8
K21R 90 L8
K21R 100 L8
K21R 100 LX8
K21R 112 M8
K21R 132 S8 T
K21R 132 S8
K21R 132 M8
K21R 160 M8
K21R 160 MX8
K21R 160 L8
K21R 180 L8
K21R 200 L8
21
Energy saving motors, High efficiency IE2
Basic version
General technical data
Energy saving motors | Special catalogue 02-2009
Motor selection data
50 Hz, 2- up to 8-pole
3000/1500/1000/750 rpm
22
Energy saving motors, High efficiency IE2
General technical data
The most important technical data is summarized in the following table.
Detailed information can be found in the catalogue part “Technical explanations”.
Type of protection
Type of cooling
Coolant temperature/
altitude of site
Rated voltage
Efficiency
Types of construction
Colour system
Vibration grade
Shaft end
Sound pressure level
Limit speeds
Bearing design
Motor weights
Terminal boxes
Documentation
Tolerances
Options
Motor with squirrel-cage rotor, IEC/DIN
0.06 kW to 315 kW
56 to 315
Grey cast iron
0.30 Nm to 2060 Nm
Motors with one speed are designed with Δ/Y-circuit as standard.
Thermal class 155, as option 155 [F(B)], 180
acc. to EN 60034-1 (IEC 60034-1)
IP 55 acc. to EN 60034-5 (IEC 60034-5), as option IP 56 and higher
IC 411 acc. to EN 60034-6 (IEC 60034-6)
As standard - 20°C up to + 40°C,
altitude of site 1000 m above sea level
Rated voltage ranges A
acc. to EN 60034-1 (IEC 60034-1),
standard voltage acc. to EN 60038
50 Hz, 230 V, 400 V, 500 V and 690 V
according to EN 60034-2-1; ≤ 1 kW direct measurement, 1.1 kW up to
150 kW summation of losses and (in line with USA, IEEE 112) additional
loss determination according to additional loss method, this method is also
used for the power range up to 315 kW corresponding with IEEE 112.
IM B3, IM B35, IM B5 and derived types of construction
acc. to EN 60034-7
Standard colour system “moderate”, colour shade RAL 7031, blue-grey
Special colour system “world wide”, colour shade RAL 7031, blue-grey
As standard grade “A” for motors without special vibration requirements
Acc. to DIN 748 (IEC 60072), balancing “with half key”
Acc. to EN ISO 1680, tolerance +3dB,
data see in the main catalogue 01-2008 part “Technical explanations”
Please refer to paragraph about limit speeds
in the main catalogue 01-2008 part “Technical explanations”.
Please refer to paragraph about bearings
in the main catalogue 01-2008 part “Technical explanations”.
Please refer to the technical selection lists.
Please refer to paragraph about terminal boxes
in the main catalogue 01-2008 part “Technical explanations”.
An operation and maintenance manual, a connection diagram and
a safety data sheet is attached to each motor.
Please refer to paragraph about tolerances
in the main catalogue 01-2008 part “Technical explanations”.
Please refer to paragraph about modifications
in the main catalogue 01-2008 part “Technical explanations”.
2
Energy saving motors | Special catalogue 02-2009
Product line
Rated output
Sizes
Material of housing
Rated torque
Types of circuit
Insulation of stator winding
23
Energy saving motors, High efficiency IE2
Energy saving motors
Efficiency determination acc. to EN 60034-2-1
with surface ventilation, mode of operation S1, continuous duty
thermal class 155, degree of protection IP 55
Motor selection data
Type
Design point 400 V, 50 Hz
PB
MB
nB
kW
Nm
rpm
Synchronous speed 3000 rpm – 2-pole version
Energy saving motors | Special catalogue 02-2009
W21R 56 K 2
W21R 56 G 2
W21R 63 K 2
W21R 63 G 2
W21R 71 K 2
W21R 71 G 2
IE2-W21R 80 K 2
IE2-WE1R 80 G 2
IE2-WE1R 90 S 2
IE2-WE1R 90 L 2
IE2-WE1R 100 L 2
IE2-WE1R 112 MX2
IE2-WE1R 112 MV2
IE2-WE1R 132 SX2
IE2-WE1R 160 M2
IE2-WE1R 160 MX2
IE2-WE1R 160 L2
IE2-WE1R 180 M2
IE2-WE1R 200 L2
IE2-WE1R 200 LX2
IE2-WE1R 225 M2
IE2-WE1R 250 M2
IE2-WE1R 280 S2
IE2-WE1R 280 M2
IE2-W21R 315 S2
IE2-W21R 315 M2
IE2-W21R 315 MX2
IE2-W21R 315 MY2
IE2-W21R 315 L2
IE2-W21R 315 LX2
24
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
110
132
160
200
250
315
0.30
0.41
0.61
0.84
1.24
1.83
2.49
3.64
4.92
7.30
9.85
13.1
18.1
24.6
35.9
48.8
60.3
71.4
97.4
120
146
178
241
289
354
424
515
640
801
1010
2830
2820
2840
2860
2860
2870
2880
2885
2910
2880
2910
2910
2900
2910
2930
2935
2930
2942
2942
2945
2945
2957
2972
2970
2970
2975
2970
2984
2980
2980
IE class
η4/4
EN 60034-2-1
%
IB
400 V
IA/IB
cos ϕB
A
-
-
-
EFF class
η4/4
η3/4
EN 60034-2
%
%
IE2-83.3
IE2-83.0
IE2-85.8
IE2-84.9
IE2-86.8
IE2-87.5
IE2-87.0
IE2-89.5
IE2-90.2
IE2-90.3
IE2-91.0
IE2-91.3
IE2-92.0
IE2-92.5
IE2-93.0
IE2-93.2
IE2-93.8
IE2-94.5
IE2-94.5
IE2-95.0
IE2-95.0
IE2-95.4
IE2-95.4
IE2-95.4
0.22
0.30
0.42
0.55
0.76
1.13
1.46
2.15
2.90
4.25
5.80
7.50
10.5
13.5
20.0
26.0
32.0
38.0
51.0
62.0
78.0
94.5
126
150
186
223
267
340
406
494
5.0
4.7
5.7
6.0
7.1
7.4
7.7
7.8
9.0
8.0
7.5
7.8
7.0
7.0
8.5
7.3
7.5
6.6
7.2
7.8
7.4
8.4
8.0
7.4
8.3
9.2
8.2
9.4
8.3
9.8
0.81
0.82
0.82
0.84
0.86
0.85
0.88
0.88
0.86
0.87
0.85
0.87
0.85
0.91
0.88
0.92
0.91
0.90
0.91
0.92
0.89
0.89
0.90
0.91
0.89
0.89
0.90
0.88
0.92
0.95
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
-
73.0
70.0
75.0
78.0
81.5
83.0
84.0
83.7
86.4
85.8
87.7
88.9
89.2
89.5
90.5
91.3
91.8
92.7
93.0
93.7
93.7
94.5
95.2
95.2
95.9
96.0
96.1
96.4
96.6
96.8
EFF-
73
69
74
77
78
80
84.5
85
84.6
86.5
87.7
87.9
88.5
89.2
89.9
91.0
91.7
92.8
93.1
93.7
93.7
94.4
95.0
95.1
95.9
96.2
96.1
96.1
96.5
96.8
MA/MB MS/MB
MK/MB
J
m
-
-
-
kgm2
kg
2.3
2.0
2.4
2.2
2.9
3.0
2.2
2.5
2.8
2.5
2.0
2.1
2.0
2.1
2.7
2.1
2.2
1.8
1.9
2.1
1.8
2.4
2.1
1.9
1.7
1.9
1.6
2.5
1.9
2.8
2.2
1.9
2.3
2.1
2.7
2.7
2.1
2.3
2.4
2.3
1.7
1.6
1.5
1.5
2.1
1.6
1.6
1.4
1.5
1.5
1.5
2.0
1.7
1.6
1.6
1.8
1.5
1.9
1.2
1.9
2.6
2.2
2.7
2.5
3.1
3.3
2.7
2.8
3.4
2.9
2.8
2.9
2.7
2.7
3.6
2.7
2.8
2.6
2.9
3.0
3.0
3.1
3.0
2.7
2.6
2.9
2.4
2.8
2.3
2.7
0.00015
0.00015
0.00025
0.00032
0.00057
0.00072
0.00132
0.00170
0.00275
0.00275
0.00450
0.00550
0.00680
0.0168
0.0258
0.0675
0.0675
0.105
0.128
0.154
0.360
0.375
0.65
0.68
1.21
1.44
1.76
2.82
3.66
4.43
4.8
4.8
6.3
7
10
11.2
15
18
23.5
23.5
31
38
46
75
100
140
140
175
210
235
300
385
510
550
730
820
955
1200
1450
1630
Energy saving motors, High efficiency IE2
Energy saving motors
Efficiency determination acc. to EN 60034-2-1
with surface ventilation, mode of operation S1, continuous duty
thermal class 155, degree of protection IP 55
Type
Design point 400 V, 50 Hz
PB
MB
nB
kW
Nm
rpm
Synchronous speed 1500 rpm – 4-pole version
W21R 56 K 4
W21R 56 G 4
W21R 63 K 4
W21R 63 G 4
W21R 71 K 4
W21R 71 G 4
W21R 80 K 4
IE2-W21R 80 G 4
IE2-WE1R 90 S 4
IE2-WE1R 90 LV 4
IE2-WE1R 100 L4
IE2-WE1R 100 LX4
IE2-WE1R 112 M4
IE2-WE1R 132 S4
IE2-WE1R 132 M4
IE2-WE1R 160 M4
IE2-WE1R 160 L4
IE2-WE1R 180 M4
IE2-WE1R 180 L4
IE2-WE1R 200 L4
IE2-WE1R 225 S4
IE2-WE1R 225 M4
IE2-WE1R 250 M4
IE2-WE1R 280 S4
IE2-WE1R 280 M4
IE2-W21R 315 S4
IE2-W21R 315 M4
IE2-W21R 315 MX4
IE2-W21R 315 MY4
IE2-W21R 315 L4
IE2-W21R 315 LX4
0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
110
132
160
200
250
315
0.41
0.63
0.82
1.21
1.67
2.47
3.67
5.01
7.32
9.91
14.4
19.7
26.2
35.8
48.7
71.4
97.5
120
142
194
240
290
354
483
580
708
849
1031
1282
1603
2019
1400
1370
1400
1425
1430
1430
1430
1430
1435
1445
1455
1455
1456
1465
1470
1472
1470
1477
1478
1479
1475
1480
1485
1483
1484
1485
1484
1482
1490
1490
1490
IE class
η4/4
EN 60034-2-1
%
IB
400 V
IA/IB
cos ϕB
A
-
-
-
EFF class
η4/4
η3/4
EN 60034-2
%
%
IE2-81.0
IE2-82.7
IE2-83.0
IE2-85.9
IE2-86.1
IE2-87.5
IE2-88.5
IE2-89.0
IE2-91.0
IE2-90.8
IE2-91.5
IE2-92.0
IE2-92.5
IE2-93.0
IE2-93.6
IE2-94.0
IE2-94.5
IE2-94.5
IE2-94.8
IE2-95.0
IE2-95.0
IE2-95.1
IE2-95.4
IE2-95.4
0.2
0.28
0.36
0.58
0.66
0.98
1.23
1.65
2.40
3.30
4.80
6.45
7.5
10.5
14.5
21.0
27.0
33.5
42.0
57.0
68.0
81.5
102
138
166
204
239
289
341
432
540
3.5
3.3
3.8
4.0
5.6
6.2
6.0
7.0
6.8
6.3
9.3
9.0
8.6
7.4
8.5
8.5
8.5
7.0
7.7
7.8
7.3
8.1
8.0
7.4
7.9
8.4
7.9
7.4
8.3
8.0
8.6
0.66
0.72
0.71
0.64
0.71
0.68
0.80
0.80
0.79
0.79
0.76
0.77
0.86
0.86
0.82
0.83
0.88
0.86
0.82
0.81
0.84
0.84
0.82
0.82
0.82
0.81
0.83
0.84
0.88
0.86
0.87
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
-
65.0
64.0
67.0
70.0
77.0
80.0
80.5
82.0
83.8
85.0
86.4
87.4
89.0
89.6
90.3
91.0
91.8
93.0
93.0
93.4
93.7
94.8
95.0
95.4
95.5
95.7
96.2
95.8
96.2
96.7
96.8
EFF-
63.5
63
66.5
70
75
77
80.5
82.5
83.8
84.2
86.0
87.8
89.2
89.4
89.9
90.4
91.5
92.7
92.5
93.0
93.5
94.7
94.7
95.5
95.5
95.8
96.3
96.0
96.2
96.8
95.8
MA/MB MS/MB
MK/MB
J
m
-
-
-
kgm2
kg
2.3
1.8
2.0
2.3
2.5
2.8
2.4
2.9
2.4
2.4
3.2
3.3
2.7
2.3
2.8
2.8
2.8
1.9
2.3
2.2
2.3
2.0
1.9
1.7
2.2
1.8
1.8
1.6
1.7
1.4
1.9
2.2
1.7
1.9
2.2
2.3
2.6
2.3
2.8
2.2
2.3
3.0
3.1
2.4
1.8
2.2
2.3
2.2
1.7
1.9
2.0
1.9
1.9
1.8
1.6
1.9
1.5
1.6
1.5
1.2
1.2
1.2
2.6
2.1
2.3
2.5
2.9
3.2
2.7
3.2
2.9
3.0
3.6
3.9
4.2
3.2
4.0
3.4
3.3
2.9
3.3
3.1
2.9
2.6
2.4
2.2
2.4
2.7
2.5
2.2
2.4
2.4
2.5
0.00024
0.00024
0.00040
0.00050
0.00087
0.00107
0.00207
0.00260
0.00400
0.00450
0.00900
0.01100
0.0170
0.035
0.035
0.078
0.115
0.168
0.168
0.275
0.313
0.525
0.95
0.95
1.10
1.96
2.27
2.73
4.82
5.93
6.82
4.8
4.8
6.3
7.1
9.9
11
14.5
17
23
24
36
45
56
90
92
124
165
210
210
280
320
390
535
550
605
760
850
975
1270
1450
1630
2
Energy saving motors | Special catalogue 02-2009
Motor selection data
25
Energy saving motors, High efficiency IE2
Energy saving motors
Efficiency determination acc. to EN 60034-2-1
with surface ventilation, mode of operation S1, continuous duty
thermal class 155, degree of protection IP 55
Motor selection data
Type
Design point 400 V, 50 Hz
PB
MB
nB
kW
Nm
rpm
Synchronous speed 1000 rpm – 6-pole version
Energy saving motors | Special catalogue 02-2009
W21R 71 K 6
W21R 71 G 6
W21R 80 K 6
W21R 80 G 6
IE2-W21R 90 S 6
IE2-W21R 90 LV6
IE2-W21R 100 LX6
IE2-W21R 112 MV6
IE2-W21R 132 S6
IE2-W21R 132 M6
IE2-W21R 132 MX6
IE2-W21R 160 M6
IE2-W21R 160 L6
IE2-W21R 180 L6
IE2-W21R 200 L6
IE2-W21R 200 LX6
IE2-W21R 225 M6
IE2-W21R 250 M6
IE2-W21R 280 S6
IE2-W21R 280 M6
IE2-W21R 315 S6
IE2-W21R 315 M6
IE2-W21R 315 MX6
IE2-W21R 315 MY6
IE2-W21R 315 L6
IE2-W21R 315 LX6
26
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
110
132
160
200
1.84
2.54
3.74
5.56
7.50
11.1
15.0
22.0
29.8
39.5
54.2
73.4
108
147
181
215
291
359
437
531
726
868
1061
1273
1551
1929
930
935
945
945
955
950
955
955
961
967
969
976
972
975
978
979
985
985
983
989
987
990
990
990
985
990
IE class
η4/4
EN 60034-2-1
%
IB
400 V
IA/IB
cos ϕB
A
-
-
-
EFF class
η4/4
η3/4
EN 60034-2
%
%
IE2-75.9
IE2-78.1
IE2-79.8
IE2-81.8
IE2-83.5
IE2-85.5
IE2-86.0
IE2-87.2
IE2-88.7
IE2-89.7
IE2-90.5
IE2-91.3
IE2-92.0
IE2-92.2
IE2-93.0
IE2-93.5
IE2-93.9
IE2-94.0
IE2-94.3
IE2-94.6
IE2-94.8
IE2-95.0
0.54
0.75
0.96
1.49
1.98
2.83
3.44
5.4
6.5
8.0
11.5
15.0
21.0
28.0
34.5
39.5
54.5
68.5
81.0
98.0
132
158
190
227
271
356
4.2
4.6
4.7
4.2
4.7
5.3
5.9
6.2
5.9
5.2
5.5
6.3
5.8
6.3
7.2
6.9
7.0
6.4
6.2
6.5
6.6
9.0
8.0
7.5
7.5
7.5
0.71
0.67
0.74
0.70
0.70
0.71
0.76
0.71
0.80
0.82
0.78
0.81
0.85
0.85
0.85
0.87
0.85
0.84
0.85
0.85
0.86
0.86
0.87
0.88
0.89
0.85
-
68.0
71.5
75.5
76.0
78.0
79.0
83.0
83.0
85.0
88.0
87.5
89.0
90.0
91.0
91.5
92.5
93.0
93.5
94.0
95.2
95.2
95.6
96.1
95.3
95.6
95.4
EFF-
67
70.5
76.5
78.0
79.0
83.0
83.0
85.7
87.4
87.5
88.0
89.8
90.0
91.4
92.3
92.6
93.3
94.0
94.5
94.5
94.6
95.9
94.9
95.2
95.1
MA/MB MS/MB
MK/MB
J
m
-
-
-
kgm2
kg
2.4
2.8
2.2
2.0
2.3
2.5
2.6
2.7
2.2
1.7
2.5
2.4
2.4
2.4
2.6
2.6
2.6
2.2
2.1
1.7
2.0
2.3
2.4
2.0
2.3
2.0
1.8
1.9
1.7
1.9
2.2
2.4
2.4
2.6
2.1
1.5
2.0
2.2
2.1
2.0
2.4
2.1
2.3
1.9
1.8
1.5
1.6
2.0
1.8
1.7
1.9
1.5
2.6
3.0
2.6
3.5
2.4
2.8
3.0
3.5
3.2
2.4
3.0
3.0
2.7
2.9
3.4
3.2
3.1
2.6
2.5
2.3
2.4
2.8
2.5
2.4
2.4
2.4
0.00130
0.00175
0.00325
0.00425
0.00625
0.00720
0.01390
0.01550
0.023
0.043
0.053
0.113
0.145
0.228
0.268
0.443
0.825
1.28
1.48
2.63
3.33
3.60
6.00
6.00
6.67
8.60
11
12.5
15
18
24
26
36
48
54
76
85
118
135
183
206
278
360
468
545
710
804
1148
1210
1250
1250
1460
Energy saving motors, High efficiency
Energy saving motors
Efficiency determination acc. to EN 60034-2-1
with surface ventilation, mode of operation S1, continuous duty
thermal class 155, degree of protection IP 55
Type
Design point 400 V, 50 Hz
PB
kW
Nm
Synchronous speed 750 rpm – 8-pole version
rpm
IB
400 V
A
W21R 80 K 8
W21R 80 G 8
W21R 90 S 8
W21R 90 LV8
W21R 100 S 8
W21R 100 LX8
W21R 112 MV8
W21R 132 S8
W21R 132 M8
W21R 160 M8
W21R 160 MX8
W21R 160 L8
W21R 180 L8
W21R 200 L8
W21R 225 S8
W21R 225 M8
W21R 250 M8
W21R 280 S8
W21R 280 M8
W21R 315 S8
W21R 315 M8
W21R 315 MX8
W21R 315 MY8
W21R 315 L8
W21R 315 LX8
710
705
710
700
715
710
700
715
717
718
719
725
730
727
730
733
737
736
740
740
740
740
740
740
740
0.63
0.82
1.16
1.92
2.27
3.20
4.25
5.6
6.9
9.3
11
16
23
31
37
44.5
59.5
72.5
85
104
143
172
207
241
306
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
MB
2.42
3.39
5.05
7.40
10.0
14.8
20.5
29.4
40.0
53.2
73.1
98.8
144
197
242
287
389
480
581
710
968
1161
1420
1704
2062
nB
IA/IB
cos ϕB
ηB
η3/4
MA/MB
MS/MB
MK/MB
J
m
-
-
%
%
-
-
-
kgm2
kg
3.5
3.5
3.1
3.8
4.6
4.3
3.8
5.5
4.4
4.6
4.6
5.5
5.8
5.6
5.6
5.6
5.5
5.4
6.7
6.9
6
6
6.5
6.3
7.2
0.61
0.63
0.63
0.64
0.62
0.63
0.65
0.70
0.74
0.72
0.81
0.77
0.76
0.77
0.79
0.78
0.78
0.79
0.81
0.81
0.81
0.81
0.81
0.83
0.79
68.0
70.0
73.0
72.0
77.0
79.0
78.0
81.5
84.8
85.7
87.3
89.0
89.8
90.0
91.1
91.7
92.8
93.0
93.9
94.6
93.3
93.5
94.8
95.3
95.5
73
75.5
78
78.5
81
84.3
85.2
86.9
88.5
88.8
89.5
90.1
90.5
92.5
92.5
93.4
94.1
93
93
94.3
94.7
95
1.9
1.9
1.7
1.7
2.6
2.0
1.7
2.0
1.5
1.6
1.6
2.0
2.0
2.0
1.7
1.8
1.8
1.8
2.2
2.3
2
1.9
2.1
2
2.2
1.6
2.5
1.9
1.6
-
2.6
2.4
1.8
2.4
3.0
2.6
2.2
3.0
2.4
2.5
2.2
2.8
2.9
2.8
2.8
2.6
2.5
2.4
2.5
2.6
2.3
2.2
2.4
2.1
2.5
0.00300
0.00375
0.00625
0.00720
0.01225
0.01390
0.01550
0.0180
0.0430
0.0530
0.1130
0.1450
0.2280
0.2680
0.44
0.83
1.35
1.55
2.63
3.33
3.33
3.6
6
6.76
8.71
14
17
25
26
33.5
36
48
53
70
86
114
136
175
200
265
360
465
520
690
800
800
880
1050
1250
1430
2
Energy saving motors | Special catalogue 02-2009
Motor selection data
27
Energy saving motors | Special catalogue 02-2009
Energy saving motors, Standard efficiency IE1
28
Dimensions
Dimensions
Dimensions
Flange dimensions
Energy saving motors, Standard efficiency IE1
Energy saving motors | Special catalogue 02-2009
Energy saving motors, High efficiency IE2
30
Dimensions
Notes to dimensions
Dimensional designations according to EN 50 347
and IEC 60 072
Flange sizes in the dimensional tables are given in
accordance to DIN 42948.
All dimensional data in mm
VEM motors GmbH reserves the right to change
technical data without preceding information.
Dimensional data in catalogues can lose their validity.
Binding dimensional data can be requested from
the VEM sales organisations.
Flange dimensions
Flanges with threadholes
Flange type
acc. to EN 50 347
Flange type
acc. to DIN 42948
LA
c1
M
e1
N
b1
P
a1
S
s1
T
f1
FT 65
FT 75
FT 85
FT 100
FT 115
FT 130
FT 165
FT 215
C 80
C 90
C 105
C 120
C 140
C 160
C 200
C 250
6.5
8
8.5
8
10
10
12
12
65
75
85
100
115
130
165
215
50
60
70
80
95
110
130
180
80
90
105
120
140
160
200
250
M5
M5
M6
M6
M8
M8
M10
M12
2.5
2.5
2.5
3
3
3.5
3.5
4
3
Flanges with through holes
Flange type
acc. to EN 50 347
Flange type
acc. to DIN 42948
LA
c1
M
e1
N
b1
P
a1
S
s1
T
f1
FF 100
FF 115
FF 130
FF 165
FF 215
FF 265
FF 300
FF 350
FF 400
FF 500
FF 600
FF 740
A 120
A 140
A 160
A 200
A 250
A 300
A 350
A 400
A 450
A 550
A 660
A 800
9
9
9
10
11
12
13
15
16
18
22
25
100
115
130
165
215
265
300
350
400
500
600
740
80
95
110
130
180
230
250
300
350
450
550
680
120
140
160
200
250
300
350
400
450
550
660
800
7
9
9
11
14
14
18
18
18
18
22
22
3
3
3.5
3.5
4
4
5
5
5
5
6
6
Tolerances for dimension N (b1) see respective dimensional tables
LA (c1) length of engagement
Energy saving motors | Special catalogue 02-2009
According to EN 50 347 the flanges FF have through holes and
the flanges FT have threadholes.
The standard DIN 42948 for flanges A and C are still valid yet.
31
Dimensions
Energy saving motors, Standard efficiency IE1
Three-phase motors with squirrel-cage rotor
Energy saving motors | Special catalogue 02-2009
Size 63 to 280
with surface ventilation, cooling method IC 411, degree of protection IP 55
Type of construction IM B3 [IM 1001]
32
Type designation
Flange
size
A
b
AA
n
AB
f
AC
g
AD
g1
B
a
BA
m
BB
e
C
w1
CA
w2
D
d
DA
d1
DB*)
E
l
EA
l1
F
u
FA
u1
K21R 63K2,4,6
K21R 63G2,4,6
K21R 71K2,4,6,8
K21R 71G2,4,6,8
IE1-K21R 80K2,4,6,8
IE1-K21R 80G2,4,6,8
IE1-K21R 90S2,4,6,8
IE1-K21R 90L2,4,6,8
IE1-K21R 100L2,4,6,8
IE1-K21R 100LX4,8
IE1-K21R 112M2
IE1-K21R 112M6,8
IE1-K21R 112MX2
IE1-K21R 112M4
IE1-K21R 132S2
IE1-K21R 132SX2
IE1-K21R 132S4,6,8
IE1-K21R 132M4
IE1-K21R 132MX6
IE1-K21R 132M6,8
IE1-K21R 160M2
IE1-K21R 160M4,6,8
IE1-K21R 160MX8
IE1-K21R 160MX2
IE1-K21R 160L2,4,6,8
IE1-K21R 180M2
IE1-K21R 180M4
IE1-K21R 180L4
IE1-K21R 180L6,8
IE1-K21R 200L2,4,6,8
IE1-K21R 200LX6
IE1-K21R 200LX2
IE1-K21R 225S4,8
IE1-K21R 225M2
IE1-K21R 225M4
IE1-K21R 225M6,8
IE1-K21R 250M2
IE1-K21R 250M4,6,8
IE1-K21R 280S2
IE1-K21R 280S4,6,8
IE1-K21R 280M2
IE1-K21R 280M4,6,8
FF 115
FF 115
FF 130
FF 130
FF 165
FF 165
FF 165
FF 165
FF 215
FF 215
FF 215
FF 215
FF 215
FF 215
FF 265
FF 265
FF 265
FF 265
FF 265
FF 265
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 350
FF 350
FF 350
FF 400
FF 400
FF 400
FF 400
FF 500
FF 500
FF 500
FF 500
FF 500
FF 500
100
100
112
112
125
125
140
140
160
160
190
190
190
190
216
216
216
216
216
216
254
254
254
254
254
279
279
279
279
318
318
318
356
356
356
356
406
406
457
457
457
457
28
28
32
32
38
38
40
40
45
32
50
50
50
50
50
50
50
50
50
50
55
55
55
55
55
62
62
62
62
70
70
70
75
75
75
75
84
84
94
94
94
94
128
128
138
138
168
168
178
178
192
188
224
224
224
224
256
256
256
256
256
256
296
296
296
296
296
328
328
328
328
372
372
372
413
413
413
413
471
471
522
522
522
522
109
109
124
124
139
139
157
157
177
196
196
196
196
196
217
217
217
258
258
217
258
258
258
313
313
351
313
351
313
351
351
390
390
390
390
390
440
440
490
490
490
490
98
98
104
104
111
111
119
119
126
136
136
136
136
136
178
178
178
199
199
178
214
214
199
242
242
261
242
261
242
261
261
300
300
300
300
300
358
358
386
386
386
386
80
80
90
90
100
100
100
125
140
140
140
140
140
140
140
140
140
178
178
178
210
210
210
210
254
241
241
279
279
305
305
305
286
311
311
311
349
349
368
368
419
419
55
55
55
55
55
55
60
60
60
60
60
65
65
65
65
70
70
70
75
75
75
75
84
84
96
96
96
96
100
100
116
116
125
125
130
155
175
171
180
180
180
180
180
180
180
218
218
218
257
257
257
257
301
288
288
326
326
360
360
360
343
368
368
368
412
412
431
431
482
482
40
40
45
45
50
50
56
56
63
63
70
70
70
70
89
89
89
89
89
89
108
108
108
108
108
121
121
121
121
133
133
133
149
149
149
149
168
168
190
190
190
190
39
39
43.5
43.5
63
63
74
71
73
102
95
95
129
129
153
173
153
138
138
135
135
135
135
148
142
169
142
176
104
138
138
193
196
211
211
171
210
210
234
234
229
229
11
11
14
14
19
19
24
24
28
28
28
28
28
28
38
38
38
38
38
38
42
42
42
42
42
48
48
48
48
55
55
55
60
55
60
60
60
65
65
75
65
75
11
11
14
14
19
19
22
22
24
28
28
28
28
28
32
32
32
38
38
32
38
38
38
42
42
48
42
48
42
48
48
55
55
55
55
55
55
55
65
65
65
65
M4
M4
M5
M5
M6
M6
M8
M8
M10
M10
M10
M10
M10
M10
M12
M12
M12
M12
M12
M12
M16
M16
M16
M16
M16
M16
M16
M16
M16
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
23
23
30
30
40
40
50
50
60
60
60
60
60
60
80
80
80
80
80
80
110
110
110
110
110
110
110
110
110
110
110
110
140
110
140
140
140
140
140
140
140
140
23
23
30
30
40
40
50
50
50
60
60
60
60
60
80
80
80
80
80
80
80
80
80
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
140
140
140
140
4
4
5
5
6
6
8
8
8
8
8
8
8
8
10
10
10
10
10
10
12
12
12
12
12
14
14
14
14
16
16
16
18
16
18
18
18
18
18
20
18
20
4
4
5
5
6
6
6
6
8
8
8
8
8
8
10
10
10
10
10
10
10
10
10
12
12
14
12
14
12
14
14
16
16
16
16
16
16
16
18
18
18
18
*) Centre holes acc. to DIN 332-DS
Dimensions
Energy saving motors, Standard efficiency IE1
Three-phase motors with squirrel-cage rotor
Size 63 to 280
with surface ventilation, cooling method IC 411, degree of protection IP 55
Type of construction IM B35 [IM 2001]
Flange dimensions see page 31
K21R 63K2,4,6
K21R 63G2,4,6
K21R 71K2,4,6,8
K21R 71G2,4,6,8
IE1-K21RK2,4,6,8
IE1-K21R 80G2,4,6,8
IE1-K21R 90S2,4,6,8
IE1-K21R 90L2,4,6,8
IE1-K21R 100L2,4,6,8
IE1-K21R 100LX4,8
IE1-K21R 112M2
IE1-K21R 112M6,8
IE1-K21R 112MX2
IE1-K21R 112M4
IE1-K21R 132S2
IE1-K21R 132SX2
IE1-K21R 132S4,6,8
IE1-K21R 132M4
IE1-K21R 132MX6
IE1-K21R 132M6,8
IE1-K21R 160M2
IE1-K21R 160M4,6,8
IE1-K21R 160MX8
IE1-K21R 160MX2
IE1-K21R 160L2,4,6,8
IE1-K21R 180M2
IE1-K21R 180M4
IE1-K21R 180L4
IE1-K21R 180L6,8
IE1-K21R 200L2,4,6,8
IE1-K21R 200LX6
IE1-K21R 200LX2
IE1-K21R 225S4,8
IE1-K21R 225M2
IE1-K21R 225M4
IE1-K21R 225M6,8
IE1-K21R 250M2
IE1-K21R 250M4,6,8
IE1-K21R 280S2
IE1-K21R 280S4,6,8
IE1-K21R 280M2
IE1-K21R 280M4,6,8
**) Terminal box left/right
GA
t
GC
t1
H
h
HA
c
HD
p
HD**)
p
HH
A
K
s
K’
s’
L
k
LC
k1
KK Type
AG
LL
O
Hole
pattern
BI.
Bl
12.5
12.5
16
16
21.5
21.5
27
27
31
31
31
31
31
31
41
41
41
41
41
41
45
45
45
45
45
51.5
51.5
51.5
51.5
59
59
59
64
59
64
64
64
69
69
79.5
69
79.5
12.5
12.5
16
16
21.5
21.5
24.5
24.5
27
31
31
31
31
31
35
35
35
41
41
35
41
41
41
45
45
51.5
45
51.5
45
51.5
51.5
59
59
59
59
59
59
59
69
69
69
69
63
63
71
71
80
80
90
90
100
100
112
112
112
112
132
132
132
132
132
132
160
160
160
160
160
180
180
180
180
200
200
200
225
225
225
225
250
250
280
280
280
280
10
10
11
11
12
12
14
14
15
11
18
18
18
18
16
16
16
16
16
16
18
18
18
18
18
20
20
20
20
22
22
22
25
25
25
25
28
28
32
32
32
32
161
161
175
175
191
191
210
210
227
237
249
249
249
249
310
310
310
331
331
310
374
374
374
402
402
441
422
441
422
461
461
500
525
525
525
525
608
608
666
666
666
666
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
257
257
257
279
279
257
307
307
307
336
336
369
356
369
369
389
389
417
442
442
442
442
484
484
546
546
546
546
58
58
61
61
67
67
70
70
75
77
77
77
77
77
108
108
108
114
114
108
114
114
114
138
138
147
138
147
138
147
147
168
168
168
168
168
177
177
206
206
206
206
8
8
8
8
10
10
10
10
12
12
12
12
12
12
12
12
12
12
12
12
15
15
15
15
15
15
15
15
15
19
19
19
19
19
19
19
24
24
24
24
24
24
8
8
8
8
10
10
10
10
12
12
12
12
12
12
12
12
12
12
12
12
15
15
15
20
20
20
20
20
20
25
25
25
25
25
25
25
30
30
30
30
30
30
179
179
206
206
249
249
275
297
331
357
357
357
391
391
459
479
459
481
481
479
559
559
559
571
609
635
609
680
609
680
680
727
757
767
797
757
862
862
924
924
970
970
205
205
239
239
293
293
330
352
386
425
425
425
459
459
542
562
542
565
565
562
643
643
643
686
724
751
724
796
724
796
796
851
881
891
921
881
977
977
1072
1072
1118
1118
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KK 25 A
KK 25 A
KK 25 A
KK 25 A
KK 25 A
KK 25 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 100 A
KK 100 A
KK 100 A
KK 100 A
KK 100 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
92
92
92
92
92
92
92
92
92
92
92
92
92
92
156
156
156
156
156
156
193
193
193
193
193
193
193
193
193
193
193
213
213
213
213
213
282
282
282
282
282
282
92
92
92
92
92
92
92
92
92
92
92
92
92
92
145
145
145
145
145
145
167
167
167
167
167
167
167
167
167
167
167
207
207
207
207
207
242
242
242
242
242
242
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
8L
8L
8L
8L
8L
8L
8L
8L
8L
8L
14
14
14
14
16
16
16
16
18
20
20
20
20
20
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
40
40
40
40
45
45
50
50
50
50
3
Energy saving motors | Special catalogue 02-2009
Type designation
33
Dimensions
Energy saving motors, Standard efficiency IE1
Three-phase motors with squirrel-cage rotor
Energy saving motors | Special catalogue 02-2009
Size 315
with surface ventilation, cooling method IC 411, degree of protection IP 55
Type of construction IM B3 [IM 1001]
34
Type designation
Flange
size
A
b
AA
n
AB
f
AC
g
AD
g1
B
a
BA
m
BA’
m1
BB
e
C
w1
CA
w2
D
d
DA
d1
DB*)
E
l
EA
l1
F
u
FA
u1
IE1-K21R 315S2
IE1-K21R 315S4,6,8
IE1-K21R 315M2
IE1-K21R 315M4,6,8
IE1-K21R 315MX2
IE1-K21R 315MX4
IE1-K21R 315MX6,8
IE1-K21R 315MX10,12
IE1-K21R 315MY2
IE1-K21R 315MY4,6,8
IE1-K21R 315L2
IE1-K21R 315L4,6,8
IE1-K21R 315LX2
IE1-K21R 315LX4
IE1-K21R 315LX6,8
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
508
508
508
508
508
508
508
508
508
508
508
508
508
508
508
126
126
126
126
126
126
126
126
110
110
110
110
110
110
110
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
550
550
550
550
550
550
550
550
610
610
610
610
610
610
610
416
416
416
416
416
416
416
416
498
498
498
498
481
481
498
406
406
457
457
457
457
457
457
457
457
508
508
508
508
508
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
150
150
150
150
-
503
503
554
554
554
554
554
554
573
573
624
624
624
624
624
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
316
316
320
320
400
400
320
320
495
495
539
564
684
689
564
65
80
65
80
65
80
80
80
65
80
65
80
65
80
80
65
70
65
70
65
70
70
70
65
70
65
70
65
70
70
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
140
170
140
170
140
170
170
170
140
170
140
170
140
170
170
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
18
22
18
22
18
22
22
22
18
22
18
22
18
22
22
18
20
18
20
18
20
20
20
18
20
18
20
18
20
20
*) Centre holes acc. to DIN 332-DS
Dimensions
Energy saving motors, Standard efficiency IE1
Three-phase motors with squirrel-cage rotor
Size 315
with surface ventilation, cooling method IC 411, degree of protection IP 55
Type of construction IM B35 [IM 2001]
Flange dimensions see page 31
Type designation
GA
t
GC
t1
H
h
HA
c
HD
p
HD**)
p
HH
A
K
s
K’
s’
L
k
LC
k1
KK Type
AG
x
LL
z
AH
-
O
r
Bl.
Bl
IE1-K21R 315S2
IE1-K21R 315S4,6,8
IE1-K21R 315M2
IE1-K21R 315M4,6,8
IE1-K21R 315MX2
IE1-K21R 315MX4
IE1-K21R 315MX6,8
IE1-K21R 315MX10,12
IE1-K21R 315MY2
IE1-K21R 315MY4,6,8
IE1-K21R 315L2
IE1-K21R 315L4,6,8
IE1-K21R 315LX2
IE1-K21R 315LX4
IE1-K21R 315LX6,8
69
85
69
85
69
85
85
85
69
85
69
85
69
85
85
69
74.5
69
74.5
69
74.5
74.5
74.5
69
74.5
69
74.5
69
74.5
74.5
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
731
731
731
731
731
731
731
731
774
774
774
774
796
796
796
595
595
595
595
595
595
595
595
628
628
628
628
628
628
628
211
211
211
211
211
211
211
211
230
230
230
230
230
230
230
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
1050
1080
1105
1135
1185
1210
1135
1135
1270
1300
1390
1420
1510
1540
1420
1218
1248
1273
1303
1353
1383
1303
1303
1448
1478
1543
1598
1688
1723
1598
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 400 B
KK 400 B
KK 400 B
KK 400 B
KK 400 B
KK 400 B
KK 400 B
282
282
282
282
282
282
282
282
315
315
315
315
315
315
315
242
242
242
242
242
242
242
242
294
294
294
294
294
294
294
265
265
265
265
265
265
265
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
**) Terminal box right/left
Energy saving motors | Special catalogue 02-2009
3
35
Dimensions
Energy saving motors, Standard efficiency IE1
Three-phase motors with squirrel-cage rotor
Size 63 to 180
with surface ventilation, cooling method IC 411, degree of protection IP 55
Type of construction IM B34 [IM 2101]
Flange dimensions see page 31
Type designation
K21R 63K2,4,6
K21R 63G2,4,6
K21R 71K2,4,6,8
K21R 71G2,4,6,8
IE1-K21R 80K2,4,6,8
IE1-K21R 80G2,4,6,8
IE1-K21R 90S2,4,6,8
IE1-K21R 90L2,4,6,8
IE1-K21R 100L2,4,6,8
IE1-K21R 100LX4,8
IE1-K21R 112M2
IE1-K21R 112M6,8
IE1-K21R 112MX2
IE1-K21R 112M4
IE1-K21R 132S2
IE1-K21R 132SX2
IE1-K21R 132S4,6,8
IE1-K21R 132M4
IE1-K21R 132MX6
IE1-K21R 132M6,8
IE1-K21R 160M2
IE1-K21R 160M4,6,8
IE1-K21R 160MX8
IE1-K21R 160MX2
IE1-K21R 160L2,4,6,8
IE1-K21R 180M4
IE1-K21R 180L6,8
Flange sizes
small
big
FT 75
FT 75
FT 85
FT 85
FT 100
FT 100
FT 115
FT 115
FT 130
FT 130
FT 130
FT 130
FT 130
FT 130
FT 130
FT 130
FT 130
FT 165
FT 165
FT 130
FT 165
FT 165
FT 165
FT 215
FT 215
FT 265
FT 265
Energy saving motors | Special catalogue 02-2009
*) Centre holes acc. to DIN 332-DS
36
FT 100
FT 100
FT 115
FT 115
FT 130
FT 130
FT 130
FT 130
FT 165
FT 165
FT 165
FT 165
FT 165
FT 165
FT 165
FT 165
FT 165
FT 215
FT 215
FT 165
FT 215
FT 215
FT 215
FT 265
FT 265
-
A
b
AA
n
AB
f
AC
g
AD
g1
B
a
BA
m
BB
e
C
w1
CA
w2
D
d
DA
d1
DB*)
E
l
EA
l1
F
u
FA
u1
100
100
112
112
125
125
140
140
160
160
190
190
190
190
216
216
216
216
216
216
254
254
254
254
254
279
279
28
28
32
32
38
38
40
40
45
32
50
50
50
50
50
50
50
50
50
50
55
55
55
55
55
62
62
128
128
138
138
168
168
178
178
192
188
224
224
224
224
256
256
256
256
256
256
296
296
296
296
296
328
328
109
109
124
124
139
139
157
157
177
196
196
196
196
196
217
217
217
258
258
217
258
258
258
313
313
313
313
98
98
104
104
111
111
119
119
126
136
136
136
136
136
178
178
178
199
199
178
214
214
199
242
242
242
242
80
80
90
90
100
100
100
125
140
140
140
140
140
140
140
140
140
178
178
178
210
210
210
210
254
241
279
55
55
55
55
55
55
60
60
60
60
60
65
65
100
100
116
116
125
125
130
155
175
171
180
180
180
180
180
180
180
218
218
218
257
257
257
257
301
288
326
40
40
45
45
50
50
56
56
63
63
70
70
70
70
89
89
89
89
89
89
108
108
108
108
108
121
121
39
39
43.5
43.5
63
63
74
71
73
102
95
95
129
129
153
173
153
138
138
135
135
135
135
148
142
142
104
11
11
14
14
19
19
24
24
28
28
28
28
28
28
38
38
38
38
38
38
42
42
42
42
42
48
48
11
11
14
14
19
19
22
22
24
28
28
28
28
28
32
32
32
38
38
32
38
38
38
42
42
42
42
M4
M4
M5
M5
M6
M6
M8
M8
M10
M10
M10
M10
M10
M10
M12
M12
M12
M12
M12
M12
M16
M16
M16
M16
M16
M16
M16
23
23
30
30
40
40
50
50
60
60
60
60
60
60
80
80
80
80
80
80
110
110
110
110
110
110
110
23
23
30
30
40
40
50
50
50
60
60
60
60
60
80
80
80
80
80
80
80
80
80
110
110
110
110
4
4
5
5
6
6
8
8
8
8
8
8
8
8
10
10
10
10
10
10
12
12
12
12
12
14
14
4
4
5
5
6
6
6
6
8
8
8
8
8
8
10
10
10
10
10
10
10
10
10
12
12
12
12
Dimensions
Energy saving motors, Standard efficiency IE1
Three-phase motors with squirrel-cage rotor
Size 63 to 180
with surface ventilation, cooling method IC 411, degree of protection IP 55
Type of construction IM B14 [IM 3601]
Flange dimensions see page 31
Type designation
K21R 63K2,4,6
K21R 63G2,4,6
K21R 71K2,4,6,8
K21R 71G2,4,6,8
IE1-K21R 80K2,4,6,8
IE1-K21R 80G2,4,6,8
IE1-K21R 90S2,4,6,8
IE1-K21R 90L2,4,6,8
IE1-K21R 100L2,4,6,8
IE1-K21R 100LX4,8
IE1-K21R 112M2
IE1-K21R 112M6,8
IE1-K21R 112MX2
IE1-K21R 112M4
IE1-K21R 132S2
IE1-K21R 132SX2
IE1-K21R 132S4,6,8
IE1-K21R 132M4
IE1-K21R 132MX6
IE1-K21R 132M6,8
IE1-K21R 160M2
IE1-K21R 160M4,6,8
IE1-K21R 160MX8
IE1-K21R 160MX2
IE1-K21R 160L2,4,6,8
IE1-K21R 180M4
IE1-K21R 180L6,8
GA
t
GC
t1
H
h
HA
c
HD
p
HD**)
p
HH
A
K
s
K’
s’
L
k
LC
k1
KK Type
AG
x
LL
z
O
r
Hole
pattern
Bl.
Bl.
12.5
12.5
16
16
21.5
21.5
27
27
31
31
31
31
31
31
41
41
41
41
41
41
45
45
45
45
45
51.5
51.5
12.5
12.5
16
16
21.5
21.5
24.5
24.5
27
31
31
31
31
31
35
35
35
41
41
35
41
41
41
45
45
45
45
63
63
71
71
80
80
90
90
100
100
112
112
112
112
132
132
132
132
132
132
160
160
160
160
160
180
180
10
10
11
11
12
12
14
14
15
11
18
18
18
18
16
16
16
16
16
16
18
18
18
18
18
20
20
161
161
175
175
191
191
210
210
227
237
249
249
249
249
328
328
328
349
349
328
389
389
389
417
417
417
417
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
275
275
275
297
297
275
322
322
322
351
351
351
364
58
58
61
61
67
67
70
70
75
77
77
77
77
77
108
108
108
114
114
108
114
114
114
138
138
138
138
8
8
8
8
10
10
10
10
12
12
12
12
12
12
12
12
12
12
12
12
15
15
15
15
15
15
15
8
8
8
8
10
10
10
10
12
12
12
12
12
12
12
12
12
12
12
12
15
15
15
20
20
20
20
179
179
206
206
249
249
275
297
331
357
357
357
391
391
459
479
459
481
481
479
559
559
559
571
609
609
609
205
205
239
239
293
293
330
352
386
425
425
425
459
459
542
562
542
565
565
562
643
643
643
686
724
724
724
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KK 25 A
KK 25 A
KK 25 A
KK 25 A
KK 25 A
KK 25 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
92
92
92
92
92
92
92
92
92
92
92
92
92
92
156
156
156
156
156
156
193
193
193
193
193
193
193
92
92
92
92
92
92
92
92
92
92
92
92
92
92
145
145
145
145
145
145
167
167
167
167
167
167
167
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
14
14
14
14
16
16
16
16
18
20
20
20
20
20
35
35
35
35
35
35
35
35
35
35
35
35
35
3
Energy saving motors | Special catalogue 02-2009
**) Terminal box left/right
37
Dimensions
Energy saving motors, Standard efficiency IE1
Three-phase motors with squirrel-cage rotor
Size 63 to 280
with surface ventilation, cooling method IC 411, degree of protection IP 55
Type of construction IM B5 [IM 3001]
Type of construction IM V1 [IM 3011]
Energy saving motors | Special catalogue 02-2009
Flange dimensions see page 31
38
Type designation
Flange
size
AC
g
AD
g1
D
d
DA DB*)
d1
K21R 63K2,4,6
K21R 63G2,4,6
K21R 71K2,4,6,8
K21R 71G2,4,6,8
IE1-K21R 80K2,4,6,8
IE1-K21R 80G2,4,6,8
IE1-K21R 90S2,4,6,8
IE1-K21R 90L2,4,6,8
IE1-K21R 100L2,4,6,8
IE1-K21R 100LX4,8
IE1-K21R 112M2
IE1-K21R 112M6,8
IE1-K21R 112MX2
IE1-K21R 112M4
IE1-K21R 132S2
IE1-K21R 132SX2
IE1-K21R 132S4,6,8
IE1-K21R 132M4
IE1-K21R 132MX6
IE1-K21R 132M6,8
IE1-K21R 160M2
IE1-K21R 160M4,6,8
IE1-K21R 160MX8
IE1-K21R 160MX2
IE1-K21R 160L2,4,6,8
IE1-K21R 180M2
IE1-K21R 180M4
IE1-K21R 180L4
IE1-K21R 180L6,8
IE1-K21R 200L2,4,6,8
IE1-K21R 200LX6
IE1-K21R 200LX2
IE1-K21R 225S4,8
IE1-K21R 225M2
IE1-K21R 225M4
IE1-K21R 225M6,8
IE1-K21R 250M2
IE1-K21R 250M4,6,8
IE1-K21R 280S2
IE1-K21R 280S4,6,8
IE1-K21R 280M2
IE1-K21R 280M4,6,8
FF 115
FF 115
FF 130
FF 130
FF 165
FF 165
FF 165
FF 165
FF 215
FF 215
FF 215
FF 215
FF 215
FF 215
FF 265
FF 265
FF 265
FF 265
FF 265
FF 265
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 350
FF 350
FF 350
FF 400
FF 400
FF 400
FF 400
FF 500
FF 500
FF 500
FF 500
FF 500
FF 500
109
109
124
124
139
139
157
157
177
196
196
196
196
196
217
217
217
258
258
217
258
258
258
313
313
351
313
351
313
351
351
390
390
390
390
390
440
440
490
490
490
490
98
98
104
104
111
111
119
119
126
136
136
136
136
136
178
178
178
199
199
178
214
214
199
242
242
261
242
261
242
261
261
300
300
300
300
300
358
358
386
386
386
386
11
11
14
14
19
19
24
24
28
28
28
28
28
28
38
38
38
38
38
38
42
42
42
42
42
48
48
48
48
55
55
55
60
55
60
60
60
65
65
75
65
75
11
11
14
14
19
19
22
22
24
28
28
28
28
28
32
32
32
38
38
32
38
38
38
42
42
48
42
48
42
48
48
55
55
55
55
55
55
55
65
65
65
65
*) Centre holes acc. to DIN 332-DS
**) Terminal box left/right
M4
M4
M5
M5
M6
M6
M8
M8
M10
M10
M10
M10
M10
M10
M12
M12
M12
M12
M12
M12
M16
M16
M16
M16
M16
M16
M16
M16
M16
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
E
l
EA
l1
F
u
FA
u1
GA
t
GC
t1
H
h
HH
A
L
k
LC
k1
KK Type
AG
LL
O
23
23
30
30
40
40
50
50
60
60
60
60
60
60
80
80
80
80
80
80
110
110
110
110
110
110
110
110
110
110
110
110
140
110
140
140
140
140
140
140
140
140
23
23
30
30
40
40
50
50
50
60
60
60
60
60
80
80
80
80
80
80
80
80
80
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
140
140
140
140
4
4
5
5
6
6
8
8
8
8
8
8
8
8
10
10
10
10
10
10
12
12
12
12
12
14
14
14
14
16
16
16
18
16
18
18
18
18
18
20
18
20
4
4
5
5
6
6
6
6
8
8
8
8
8
8
10
10
10
10
10
10
10
10
10
12
12
14
12
14
12
14
14
16
16
16
16
16
16
16
18
18
18
18
12.5
12.5
16
16
21.5
21.5
27
27
31
31
31
31
31
31
41
41
41
41
41
41
45
45
45
45
45
51.5
51.5
51.5
51.5
59
59
59
64
59
64
64
64
69
69
79.5
69
79.5
12.5
12.5
16
16
21.5
21.5
24.5
24.5
27
31
31
31
31
31
35
35
35
41
41
35
41
41
41
45
45
51.5
45
51.5
45
51.5
51.5
59
59
59
59
59
59
59
69
69
69
69
63
63
71
71
80
80
90
90
100
100
112
112
112
112
132
132
132
132
132
132
160
160
160
160
160
180
180
180
180
200
200
200
225
225
225
225
250
250
280
280
280
280
58
58
61
61
67
67
70
70
75
77
77
77
77
77
108
108
108
114
114
108
114
114
114
138
138
147
138
147
138
147
147
168
168
168
168
168
177
177
206
206
206
206
179
179
206
206
249
249
275
297
331
357
357
391
391
391
459
479
459
481
481
479
559
559
559
571
609
635
609
680
609
680
680
727
757
767
797
757
862
862
924
924
970
970
205
205
239
239
293
293
330
352
386
425
425
425
459
459
542
562
542
565
565
562
643
643
643
686
724
751
724
796
724
796
796
851
881
891
921
881
977
977
1072
1072
1118
1118
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KK 25 A
KK 25 A
KK 25 A
KK 25 A
KK 25 A
KK 25 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 100 A
KK 100 A
KK 100 A
KK 100 A
KK 100 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
92
92
92
92
92
92
92
92
92
92
92
92
92
92
156
156
156
156
156
156
193
193
193
193
193
193
193
193
193
193
193
213
213
213
213
213
282
282
282
282
282
282
92
92
92
92
92
92
92
92
92
92
92
92
92
92
145
145
145
145
145
145
167
167
167
167
167
167
167
167
167
167
167
207
207
207
207
207
242
242
242
242
242
242
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
Hole BI.
pattern Bl
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
8L
8L
8L
8L
8L
8L
8L
8L
8L
8L
14
14
14
14
16
16
16
16
18
20
20
20
20
20
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
40
40
40
40
45
45
50
50
50
50
Dimensions
Energy saving motors, Standard efficiency IE1
Three-phase motors with squirrel-cage rotor
Size 315
with surface ventilation, cooling method IC 411, degree of protection IP 55
Type of construction IM B5 [IM 3001] up to size 315 MY
Type of construction IM V1 [IM 3011]
Flange dimensions see page 31
Type designation
Flange
size
AC
g
AD
g1
D
d
DA DB*)
d1
IE1-K21R 315S2
IE1-K21R 315S4,6,8
IE1-K21R 315M2
IE1-K21R 315M4,6,8
IE1-K21R 315MX2
IE1-K21R 315MX4
IE1-K21R 315MX6,8
IE1-K21R 315MX10,12
IE1-K21R 315MY2
IE1-K21R 315MY4,6,8
IE1-K21R 315L2
IE1-K21R 315L4,6,8
IE1-K21R 315LX2
IE1-K21R 315LX4
IE1-K21R 315LX6,8
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
550
550
550
550
550
550
550
550
610
610
610
610
610
610
610
416
416
416
416
416
416
416
416
498
498
498
498
481
481
498
65
80
65
80
65
80
80
80
65
80
65
80
65
80
80
65
70
65
70
65
70
70
70
65
70
65
70
65
70
70
*) Centre holes acc. to DIN 332-DS
**) Terminal box right/left
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
E
l
EA
l1
F
u
FA
u1
GA
t
GC
t1
H
h
HH
A
L
k
LC
k1
KK Type
AG
x
LL
z
AH
-
O
r
Bl.
Bl
140
170
140
170
140
170
170
170
140
170
140
170
140
170
170
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
18
22
18
22
18
22
22
22
18
22
18
22
18
22
22
18
20
18
20
18
20
20
20
18
20
18
20
18
20
20
69
85
69
85
69
85
85
85
69
85
69
85
69
85
85
69
74.5
69
74.5
69
74.5
74.5
74.5
69
74.5
69
74.5
69
74.5
74.5
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
211
211
211
211
211
211
211
211
230
230
230
230
230
230
230
1050
1080
1105
1135
1185
1215
1135
1135
1270
1300
1390
1420
1510
1540
1420
1218
1248
1273
1303
1353
1383
1303
1303
1448
1478
1543
1598
1688
1723
1598
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 400 B
KK 400 B
KK 400 B
KK 400 B
KK 400 B
KK 400 B
KK 400 B
282
282
282
282
282
282
282
282
315
315
315
315
315
315
315
242
242
242
242
242
242
242
242
294
294
294
294
294
294
294
265
265
265
265
265
265
265
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
Energy saving motors | Special catalogue 02-2009
3
39
Dimensions
Energy saving motors, Standard efficiency IE1
Three-phase motors with squirrel-cage rotor
Size 355
with surface ventilation, cooling method IC 411, degree of protection IP 55
Type of construction IM B3 [IM 1001]
Type of construction IM B35 [IM 2001]
Energy saving motors | Special catalogue 02-2009
Flange dimensions see page 31
40
Type designation
Flange
size
A
b
AA
n
AB
f
AC
g
B
a
BA
m
BA’
m1
BB
e
C
w1
CA
w2
D
d
DA
d1
DB*)
E
l
EA
l1
F
u
FA
u1
IE1-K22R 355MY2,M2
IE1-K22R 355MY4,6,8
IE1-K22R 355M4
IE1-K22R 355M6,8
IE1-K22R 355MX6,8
K22R 355MX2
K22R 355LY2,L2
K22R 355MX4
K22R 355LY4,L4
IE1-K22R 355LY6,8
FF 740
FF 740
FF 740
FF 740
FF 740
FF 740
FF 740
FF 740
FF 740
FF 740
610
610
610
610
610
610
610
610
610
610
130
130
130
130
130
130
130
130
130
130
700
700
700
700
700
700
700
700
700
700
715
715
715
715
715
715
715
715
715
715
560
560
560
560
560
560
630
560
630
630
140
140
140
140
140
140
140
140
140
140
200
200
200
200
200
200
200
200
200
200
750
750
750
750
750
750
750
750
750
750
254
254
254
254
254
254
254
254
254
254
561
561
561
561
681
681
611
681
611
611
80
100
100
100
100
80
80
100
100
100
80
80
80
80
80
80
80
80
80
80
M20
M24
M24
M24
M24
M20
M20
M24
M24
M24
170
210
210
210
210
170
170
210
210
210
170
170
170
170
170
170
170
170
170
170
22
28
28
28
28
22
22
28
28
28
22
22
22
22
22
22
22
22
22
22
Type designation
GA
t
GC
t1
H
h
HA
c
HD
p
HD**)
p
HH
A
K
s
K’
s’
L
k
LC
k1
KK Type
AG
x
LL
z
AH
-
BE
-
O
r
Bl.
Bl
IE1-K22R 355MY2,M2
IE1-K22R 355MY4,6,8
IE1-K22R 355M4
IE1-K22R 355M6,8
K22R 355MX6,8
K22R 355MX2
K22R 355LY2,L2
K22R 355MX4
K22R 355LY4,L4
IE1-K22R 355LY6,8
85
106
106
106
106
85
85
106
106
106
85
85
85
85
85
85
85
85
85
85
355
355
355
355
355
355
355
355
355
355
44
44
44
44
44
44
44
44
44
44
1091
1091
1091
1091
1091
1083
1083
1083
1083
1083
1172
1172
1172
1172
1172
1174
1174
1174
1174
1174
250
250
250
250
327
327
327
327
327
327
28
28
28
28
28
28
28
28
28
28
35
35
35
35
35
35
35
35
35
35
1530
1570
1570
1570
1690
1650
1650
1690
1690
1690
1715
1755
1755
1755
1875
1835
1835
1875
1875
1875
KK 630 A
KK 630 A
KK 630 A
KK 630 A
KK 630 A
KK 1000 A
KK 1000 A
KK 1000 A
KK 1000 A
KK 1000 A
496
496
496
496
496
615
615
615
615
615
390
390
390
390
390
474
474
474
474
474
301
301
301
301
301
385
385
385
385
385
140
140
140
140
140
200
200
200
200
200
M72x2
M72x2
M72x2
M72x2
M72x2
M72x2
M72x2
M72x2
M72x2
M72x2
60
60
60
60
60
60
60
60
60
60
*) Centre holes acc. to DIN 332-DS
**) Terminal box tilted right/left
Dimensions
Energy saving motors, Standard efficiency IE1
Three-phase motors with squirrel-cage rotor
Size 355
with surface ventilation, cooling method IC 411, degree of protection IP 55
Type of construction IM V1 [IM 3011]
Flange dimensions see page 31
Type designation
Flange AC
size
g
AD AD**) D
g1
g1 d
DA DB*)
d1
IE1-K22R 355MY2,M2
IE1-K22R 355MY4,6,8
IE1-K22R 355M4
IE1-K22R 355M6,8
IE1-K22R 355MX6,8
K22R 355MX2
K22R 355LY2,L2
K22R 355MX4
K22R 355LY,L4
IE1-K22R 355LY6,8
FF 740
FF 740
FF 740
FF 740
FF 740
FF 740
FF 740
FF 740
FF 740
FF 740
736
736
736
736
736
728
728
728
728
728
80
80
80
80
80
80
80
80
80
80
715
715
715
715
715
715
715
715
715
715
817
817
817
817
817
819
819
819
819
819
80
100
100
100
100
80
80
100
100
100
M20
M24
M24
M24
M24
M20
M20
M24
M24
M24
E
l
EA
l1
F
u
FA
u1
GA
t
GC
t1
H
h
HH
A
L
k
LC
k1
KK Type
AG
x
LL
z
AH
-
BE
-
O
r
Bl.
Bl
170
210
210
210
210
170
170
210
210
210
170
170
170
170
170
170
170
170
170
170
22
28
28
28
28
22
22
28
28
28
22
22
22
22
22
22
22
22
22
22
85
106
106
106
106
85
85
106
106
106
85
85
85
85
85
85
85
85
85
85
355
355
355
355
355
355
355
355
355
355
250
250
250
250
327
327
327
327
327
327
1530
1570
1570
1570
1690
1650
1650
1690
1690
1690
1715
1755
1755
1755
1875
1835
1835
1875
1875
1875
KK 630 A
KK 630 A
KK 630 A
KK 630 A
KK 630 A
KK 1000 A
KK 1000 A
KK 1000 A
KK 1000 A
KK 1000 A
496
496
496
496
496
615
615
615
615
615
390
390
390
390
390
474
474
474
474
474
301
301
301
301
301
385
385
385
385
385
140
140
140
140
140
200
200
200
200
200
M72x2
M72x2
M72x2
M72x2
M72x2
M72x2
M72x2
M72x2
M72x2
M72x2
60
60
60
60
60
60
60
60
60
60
3
Energy saving motors | Special catalogue 02-2009
*) Centre holes acc. to DIN 332-DS
**) Terminal box tilted right/left
41
Dimensions
Energy saving motors, High efficiency IE2
Three-phase motors with squirrel-cage rotor
Energy saving motors | Special catalogue 02-2009
Size 56 to 280
with surface ventilation, cooling method IC 411, degree of protection IP 55
Type of construction IM B3 [IM 1001]
42
Type designation
Flange
size
A
b
AA
n
AB
f
AC
g
AD
g1
B
a
BA
m
BB
e
C
w1
CA
w2
D
d
DA
d1
DB*)
E
l
EA
l1
F
u
FA
u1
W21R 56K2, 4
W21R 56G2, 4
W21R 63K2, 4
W21R 63G2, 4
W21R 71K2, 4, 6
W21R 71G2, 4, 6
IE2-W21R 80K2, 4, 6, 8
IE2-WE1R 80G2
IE2-W21R 80G4, 6, 8
IE2-WE1R 90S2, 4
IE2-W21R 90S6, 8
IE2-WE1R 90L2
IE2-WE1R 90LV4
IE2-W21R 90LV6, 8
IE2-W21R 100S8
IE2-WE1R 100L2
IE2-WE1R 100L4
IE2-WE1R 100LX4
IE2-W21R 100LX6, 8
IE2-WE1R 112MX2
IE2-WE1R 112M4
IE2-W21R 112MV6, 8
IE2-WE1R 132S2T
IE2-WE1R 132SX2
IE2-WE1R 132S4
IE2-W21R 132S6, 8
IE2-WE1R 132M4
IE2-W21R 132M6, 8
IE2-W21R 132MX6
IE2-WE1R 160M2
IE2-WE1R 160M4
IE2-W21R 160M8
IE2-W21R 160M6, MX8
IE2-WE1R 160MX2
IE2-WE1R 160L2
IE2-WE1R 160L4
IE2-W21R 160L6, 8
IE2-WE1R 180M2
IE2-WE1R 180M4
IE2-WE1R 180L4
IE2-W21R 180L6, 8
IE2-WE1R 200L2
IE2-WE1R 200 LX2
IE2-WE1R 200L4
IE2-W21R 200LX6
IE2-W21R 200L6, 8
IE2-WE1R 225M2
IE2-WE1R 225S4
IE2-WE1R 225M4
IE2-W21R 225S8
IE2-W21R 225M6
IE2-W21R 225M8
IE2-WE1R 250M2
IE2-WE1R 250M4
IE2-W21R 250M6, 8
IE2-WE1R 280S2
IE2-WE1R 280M2
IE2-WE1R 280S4
IE2-WE1R 280M4
IE2-W21R 280S6
IE2-W21R 280S8
IE2-W21R 280M6, 8
FF 100
FF 100
FF 115
FF 115
FF 130
FF 130
FF 165
FF 165
FF 165
FF 165
FF 165
FF 165
FF 165
FF 165
FF 215
FF 215
FF 215
FF 215
FF 215
FF 215
FF 215
FF 215
FF 265
FF 265
FF 265
FF 265
FF 265
FF 265
FF 265
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 350
FF 350
FF 350
FF 350
FF 350
FF 400
FF 400
FF 400
FF 400
FF 400
FF 400
FF 500
FF 500
FF 500
FF 500
FF 500
FF 500
FF 500
FF 500
FF 500
FF 500
90
90
100
100
112
112
125
125
125
140
140
140
140
140
160
160
160
160
160
190
190
190
216
216
216
216
216
216
216
254
254
254
254
254
254
254
254
279
279
279
279
318
318
318
318
318
356
356
356
356
356
356
406
406
406
457
457
457
457
457
457
457
18
18
21
21
23
23
26
26
26
25
25
25
25
25
32
32
32
40
32
50
45
50
50
50
50
50
50
50
50
55
55
55
55
55
55
55
55
62
62
62
62
70
70
70
70
70
75
75
75
75
75
75
84
84
84
94
94
94
94
94
94
88
110
110
120
120
135
135
152
152
152
167
167
167
167
167
188
188
188
188
224
224
226
224
256
256
256
256
256
256
256
296
296
296
296
296
296
296
296
328
328
328
328
372
372
372
372
372
413
413
413
413
413
413
471
469
469
522
522
522
522
522
522
522
109
109
124
124
139
139
157
157
157
177
177
177
177
177
196
196
196
196
196
196
217
196
196
258
258
217
258
258
258
258
313
258
313
313
313
313
313
351
351
351
351
351
351
390
390
351
390
390
440
390
440
440
440
490
490
490
490
490
490
490
490
550
178
199
199
178
199
199
199
214
242
214
242
242
242
242
242
261
261
261
261
261
261
300
300
261
300
300
324
300
324
324
358
386
386
386
386
386
386
386
386
416
71
71
80
80
90
90
100
100
100
100
100
125
125
125
140
140
140
140
140
140
140
140
140
140
140
140
178
178
178
210
210
210
210
210
254
254
254
241
241
279
279
305
305
305
305
305
311
286
311
286
311
311
349
349
349
368
419
368
419
419
419
419
42
47
47
55
47
55
47
60
60
60
60
56
60
60
60
65
65
65
65
70
70
70
70
70
75
75
75
75
75
75
84
84
84
96
96
96
96
96
96
94
86
86
95
95
114
114
124
146
146
150
150
150
150
150
171
171
205
180
180
180
172
180
180
180
180
180
218
218
218
257
257
257
257
257
301
301
301
288
288
326
326
360
360
360
360
360
368
343
343
368
368
368
412
412
412
431
482
431
482
431
431
482
36
36
40
40
45
45
50
50
50
56
56
56
56
56
63
63
63
63
63
70
70
70
89
89
89
89
89
89
89
108
108
108
108
108
108
108
108
121
121
121
121
133
133
133
133
133
149
149
149
149
149
149
168
168
168
190
190
190
190
190
190
190
52
52
59
59
78
78
80
102
102
120
120
95
135
135
102
102
136
159
136
129
172
159
159
176
186
173
186
138
186
185
178
135
148
185
142
200
142
169
214
176
176
138
188
193
193
138
211
196
267
211
267
267
210
275
275
234
229
234
229
229
229
384
9
9
11
11
14
14
19
19
19
24
24
24
24
24
28
28
28
28
28
28
32
28
38
38
38
38
38
38
38
42
42
42
42
42
42
42
42
48
48
48
48
55
55
55
55
55
55
60
60
60
60
60
60
65
65
65
65
75
75
75
75
75
9
9
11
11
14
14
19
19
19
24
24
24
24
24
28
28
28
28
28
28
32
28
28
32
32
32
38
32
38
38
38
38
38
42
42
42
42
48
42
48
42
48
48
55
55
48
55
55
55
55
55
55
55
55
55
65
65
65
65
65
65
65
M3
M3
M4
M4
M5
M5
M6
M6
M6
M8
M8
M8
M8
M8
M10
M10
M10
M10
M10
M10
M12
M10
M12
M12
M12
M12
M12
M12
M12
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
20
20
23
23
30
30
40
40
40
50
50
50
50
50
60
60
60
60
60
60
80
60
80
80
80
80
80
80
80
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
20
20
23
23
30
30
40
40
40
50
50
50
50
50
60
60
60
60
60
60
80
60
80
80
80
80
80
80
80
80
80
80
80
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
140
140
140
140
140
140
140
3
3
4
4
5
5
6
6
6
8
8
8
8
8
8
8
8
8
8
8
10
8
10
10
10
10
10
10
10
12
12
12
12
12
12
12
12
14
14
14
14
16
16
16
16
16
16
18
18
18
18
18
18
18
18
18
18
20
20
20
20
20
3
3
4
4
5
5
6
6
6
8
8
8
8
8
8
8
8
8
8
8
10
8
10
10
10
10
10
10
10
10
10
10
10
12
12
12
12
14
12
14
14
14
14
16
16
14
16
16
16
16
16
16
16
16
16
18
18
18
18
18
18
18
*) Centre holes acc. to DIN 332-DS
Dimensions
Energy saving motors, High efficiency IE2
Three-phase motors with squirrel-cage rotor
Size 56 to 280
with surface ventilation, cooling method IC 411, degree of protection IP 55
Type of construction IM B35 [IM 2001]
Flange dimensions see page 31
W21R 56K2, 4
W21R 56G2, 4
W21R 63K2, 4
W21R 63G2, 4
W21R 71K2, 4, 6
W21R 71G2, 4, 6
IE2-W21R 80K2, 4, 6, 8
IE2-WE1R 80G2
IE2-W21R 80G4, 6, 8
IE2-WE1R 90S2, 4
IE2-W21R 90S6, 8
IE2-WE1R 90L2
IE2-WE1R 90LV4
IE2-W21R 90LV6, 8
IE2-W21R 100S8
IE2-WE1R 100L2
IE2-WE1R 100L4
IE2-WE1R 100LX4
IE2-W21R 100LX6, 8
IE2-WE1R 112MX2
IE2-WE1R 112M4
IE2-W21R 112MV6, 8
IE2-WE1R 132S2T
IE2-WE1R 132SX2
IE2-WE1R 132S4
IE2-W21R 132S6, 8
IE2-WE1R 132M4
IE2-W21R 132M6, 8
IE2-W21R 132MX6
IE2-WE1R 160M2
IE2-WE1R 160M4
IE2-W21R 160M8
IE2-W21R 160M6, MX8
IE2-WE1R 160MX2
IE2-WE1R 160L2
IE2-WE1R 160L4
IE2-W21R 160L6, 8
IE2-WE1R 180M2
IE2-WE1R 180M4
IE2-WE1R 180L4
IE2-W21R 180L6, 8
IE2-WE1R 200L2
IE2-WE1R 200 LX2
IE2-WE1R 200L4
IE2-W21R 200LX6
IE2-W21R 200L6, 8
IE2-WE1R 225M2
IE2-WE1R 225S4
IE2-WE1R 225M4
IE2-W21R 225S8
IE2-W21R 225M6
IE2-W21R 225M8
IE2-WE1R 250M2
IE2-WE1R 250M4
IE2-W21R 250M6, 8
IE2-WE1R 280S2
IE2-WE1R 280M2
IE2-WE1R 280S4
IE2-WE1R 280M4
IE2-W21R 280S6
IE2-W21R 280S8
IE2-W21R 280M6, 8
**) Terminal box left/right
GA
t
GC
t1
H
h
HA
c
HD
p
HD**)
p
HH
A
K
s
K’
s’
L
k
LC
k1
KK Type
AG
x
LL
z
O
-
Hole
pattern
BI.
Bl
10.2
10.2
12.5
12.5
16
16
21.5
21.5
21.5
27
27
27
27
27
31
31
31
31
31
31
35
31
41
41
41
41
41
41
41
45
45
45
45
45
45
45
45
51.5
51.5
51.5
51.5
59
59
59
59
59
59
64
64
64
64
64
64
69
69
69
69
79.5
79.5
79.5
79.5
79.5
10.2
10.2
12.5
12.5
16
16
21.5
21.5
21.5
27
27
27
27
27
31
31
31
31
31
31
35
31
31
41
41
35
41
41
41
41
41
41
41
45
45
45
45
51.5
45
51.5
45
51.5
51.5
59
59
51.5
59
59
59
59
59
59
59
59
59
69
69
69
69
69
69
69
56
56
63
63
71
71
80
80
80
90
90
90
90
90
100
100
100
100
100
112
112
112
132
132
132
132
132
132
132
160
160
160
160
160
160
160
160
180
180
180
180
200
200
200
200
200
225
225
225
225
225
225
250
250
250
280
280
280
280
280
280
280
7
7
7.5
7.5
8
8
9
9
9
9.5
9.5
9.5
9.5
9.5
11
11
11
18
18
18
15
18
18
15
15
16
15
16
15
18
18
18
18
18
18
18
18
20
20
20
20
22
22
22
22
22
25
25
25
25
25
25
28
28
28
32
32
32
32
32
32
40
154
154
167
167
182
182
200
200
200
217
217
217
217
217
237
237
237
249
249
249
290
249
287
331
331
310
331
331
331
374
402
374
402
402
402
402
402
441
441
441
441
461
461
500
500
461
525
525
549
525
549
549
608
636
636
666
666
666
666
666
666
696
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
58
58
61
61
67
67
70
70
70
75
75
75
75
75
77
77
77
77
77
77
108
77
96
114
114
108
114
114
114
114
138
138
138
138
138
138
138
147
147
147
147
147
147
168
168
147
168
168
177
168
177
177
177
206
206
206
206
206
206
206
206
211
6
6
7
7
7
7
10
10
10
10
10
10
10
10
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
15
15
15
15
15
15
15
15
15
15
15
15
19
19
19
19
19
19
19
19
19
19
19
24
24
24
24
24
24
24
24
24
24
6
6
7
7
7
7
10
10
10
10
10
10
10
10
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
15
20
15
20
20
20
20
20
20
20
20
20
25
25
25
25
25
25
25
25
25
25
25
30
30
30
30
30
30
30
30
30
30
176
176
199
199
239
239
265
287
287
321
321
321
362
362
357
357
391
421
357
391
459
421
460
481
529
479
529
481
529
605
571
559
571
609
609
667
609
635
680
680
680
680
730
727
727
680
767
757
862
797
862
862
862
924
924
924
970
924
970
970
970
1105
199
199
225
225
273
273
310
332
332
376
376
376
416
416
425
425
459
489
425
459
542
489
528
565
613
562
613
565
613
689
656
643
656
724
724
783
724
751
796
796
796
796
846
851
851
796
891
881
977
921
977
977
977
1042
1042
1072
1118
1072
1118
1118
1118
1273
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KK 25 A
KA 05
KK Ex
KK 25 A
KK 25 A
KK 25 A
KK 25 A
KK 25 A
KK 25 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 100 A
KK 100 A
KK 63 A
KK 100 A
KK 100 A
KK 100 A
KK 100 A
KK 100 A
KK 100 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
156
92
104
156
156
156
156
156
156
193
193
193
193
193
193
193
193
193
193
193
193
193
193
213
213
193
213
213
213
213
213
213
282
282
282
282
282
282
282
282
282
282
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
145
92
112
145
145
145
145
145
145
167
167
167
167
167
167
167
167
167
167
167
167
167
167
207
207
167
207
207
207
207
207
207
242
242
242
242
242
242
242
242
242
242
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M32x1.5
M25x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
8L
8L
8L
8L
8L
8L
8L
8L
8L
8L
8L
8L
8L
8L
8L
8L
14
14
14
14
16
16
16
16
16
18
18
18
18
18
20
20
20
20
20
20
35
20
20
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
40
40
45
40
45
45
45
50
50
50
50
50
50
50
50
55
3
Energy saving motors | Special catalogue 02-2009
Type designation
43
Dimensions
Energy saving motors, High efficiency IE2
Three-phase motors with squirrel-cage rotor
Energy saving motors | Special catalogue 02-2009
Size 315
with surface ventilation, cooling method IC 411, degree of protection IP 55
Type of construction IM B3 [IM 1001]
44
Type designation
Flange
size
A
b
AA
n
AB
f
AC
g
AD
g1
B
a
BA
m
BA’
m1
BB
e
C
w1
CA
w2
D
d
DA
d1
DB*)
E
l
EA
l1
F
u
FA
u1
IE2-W21R 315S2
IE2-W21R 315M2
IE2-W21R 315MX2
IE2-W21R 315MY2
IE2-W21R 315L2
IE2-W21R 315LX2
IE2-W21R 315S4
IE2-W21R 315M4
IE2-W21R 315MX4
IE2-W21R 315MY4
IE2-W21R 315L4
IE2-W21R 315LX4
IE2-W21R 315S6
IE2-W21R 315M6
IE2-W21R 315MX6
IE2-W21R 315MY6
IE2-W21R 315L6
IE2-W21R 315LX6
IE2-W21R 315S8
IE2-W21R 315M8
IE2-W21R 315MX8
IE2-W21R 315MY8
IE2-W21R 315L6
IE2-W21R 315LX8
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
508
508
508
508
508
508
508
508
508
508
508
508
508
508
508
508
508
508
508
508
508
508
508
508
126
126
126
110
110
110
126
126
126
110
110
110
126
126
110
110
110
110
126
126
110
110
110
110
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
550
550
550
610
610
610
550
550
550
610
610
610
550
550
610
610
610
610
550
550
610
610
610
610
416
416
416
498
498
498
416
416
416
498
498
498
416
416
498
498
498
498
416
416
498
498
498
498
406
457
457
457
508
508
406
457
457
457
508
508
406
457
457
457
508
508
406
457
457
457
508
508
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
150
150
150
150
150
150
150
150
-
503
554
554
573
624
624
503
554
554
573
624
624
554
554
573
573
624
624
554
554
573
573
624
624
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
316
320
400
495
539
684
316
320
400
495
564
689
320
320
495
495
564
564
320
320
495
495
564
564
65
65
65
65
65
65
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
65
65
65
65
65
65
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
140
140
140
140
140
140
170
170
170
170
170
170
170
170
170
170
170
170
170
170
170
170
170
170
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
18
18
18
18
18
18
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
18
18
18
18
18
18
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
*) Centre holes acc. to DIN 332-DS
Dimensions
Energy saving motors, High efficiency IE2
Three-phase motors with squirrel-cage rotor
Size 315
with surface ventilation, cooling method IC 411, degree of protection IP 55
Type of construction IM B35 [IM 2001]
Flange dimensions see page 31
Type designation
GA
t
GC
t1
H
h
HA
c
HD
p
HD**)
p
HH
A
K
s
K’
s’
L
k
LC
k1
KK Type
AG
x
LL
z
AH
-
O
r
Bl.
Bl
IE2-W21R 315S2
IE2-W21R 315M2
IE2-W21R 315MX2
IE2-W21R 315MY2
IE2-W21R 315L2
IE2-W21R 315LX2
IE2-W21R 315S4
IE2-W21R 315M4
IE2-W21R 315MX4
IE2-W21R 315MY4
IE2-W21R 315L4
IE2-W21R 315LX4
IE2-W21R 315S6
IE2-W21R 315M6
IE2-W21R 315MX6
IE2-W21R 315MY6
IE2-W21R 315L6
IE2-W21R 315LX6
IE2-W21R 315S8
IE2-W21R 315M8
IE2-W21R 315MX8
IE2-W21R 315MY8
IE2-W21R 315L8
IE2-W21R 315LX8
69
69
69
69
69
69
85
85
85
85
85
85
85
85
85
85
85
85
85
85
85
85
85
85
69
69
69
69
69
69
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
731
731
731
809
809
809
731
731
731
809
809
809
731
731
809
809
809
809
731
731
809
809
809
809
595
595
595
628
628
628
595
595
595
628
628
628
595
595
628
628
628
628
595
595
628
628
628
628
211
211
211
230
230
230
211
211
211
230
230
230
211
211
230
230
230
230
211
211
230
230
230
230
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
1050
1105
1185
1270
1390
1510
1080
1135
1215
1300
1420
1540
1135
1135
1300
1300
1420
1420
1135
1135
1300
1300
1420
1420
1218
1273
1353
1448
1543
1688
1248
1303
1383
1478
1598
1723
1303
1303
1478
1478
1598
1598
1303
1303
1478
1478
1598
1598
KK 200 A
KK 200 A
KK 200 A
KK 400 B
KK 400 B
KK 400 B
KK 200 A
KK 200 A
KK 200 A
KK 400 B
KK 400 B
KK 400 B
KK 200 A
KK 200 A
KK 400 B
KK 400 B
KK 400 B
KK 400 B
KK 200 A
KK 200 A
KK 400 B
KK 400 B
KK 400 B
KK 400 B
282
282
282
415
415
415
282
282
282
415
415
415
282
282
415
415
415
415
282
282
415
415
415
415
242
242
242
340
340
340
242
242
242
340
340
340
242
242
340
340
340
340
242
242
340
340
340
340
265
265
265
265
265
265
265
265
265
265
265
265
265
265
265
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
**) Terminal box right/left
Energy saving motors | Special catalogue 02-2009
3
45
Dimensions
Energy saving motors, High efficiency IE2
Three-phase motors with squirrel-cage rotor
Size 56 to 160
with surface ventilation, cooling method IC 411, degree of protection IP 55
Type of construction IM B34 [IM 2101]
Flange dimensions see page 31
Energy saving motors | Special catalogue 02-2009
Type designation
46
W21R 56K2, 4
W21R 56G2, 4
W21R 63K2, 4
W21R 63G2, 4
W21R 71K2, 4, 6
W21R 71G2, 4, 6
IE2-W21R 80K2, 4, 6, 8
IE2-WE1R 80G2
IE2-W21R 80G4, 6, 8
IE2-WE1R 90S2, 4
IE2-W21R 90S6, 8
IE2-WE1R 90L2
IE2-WE1R 90LV4
IE2-W21R 90LV6, 8
IE2-W21R 100S8
IE2-WE1R 100L2
IE2-WE1R 100L4
IE2-WE1R 100LX4
IE2-W21R 100LX6, 8
IE2-WE1R 112MX2
IE2-WE1R 112M4
IE2-W21R 112MV6, 8
IE2-WE1R 132S2T
IE2-WE1R 132SX2
IE2-WE1R 132S4
IE2-W21R 132S6, 8
IE2-WE1R 132M4
IE2-W21R 132M6, 8
IE2-W21R 132MX6
IE2-WE1R 160M2
IE2-WE1R 160M4
IE2-W21R 160M8
IE2-W21R 160M6, MX8
IE2-WE1R 160MX2
IE2-WE1R 160L2
IE2-WE1R 160L4
IE2-W21R 160L6, 8
Flange sizes
small
big
FT 65
FT 65
FT 75
FT 75
FT 85
FT 85
FT 100
FT 100
FT 100
FT 115
FT 115
FT 115
FT 115
FT 115
FT 130
FT 130
FT 130
FT 130
FT 130
FT 130
FT 130
FT 130
FT 130
FT 130
FT 130
FT 130
FT 165
FT 165
FT 165
FT 165
FT 165
FT 165
FT 215
FT 215
FT 215
FT 215
FT 215
*) Centre holes acc. to DIN 332-DS
FT 85
FT 85
FT 85
FT 85
FT 100
FT 100
FT 115
FT 115
FT 115
FT 130
FT 130
FT 130
FT 130
FT 130
FT 165
FT 165
FT 165
FT 165
FT 165
FT 165
FT 165
FT 165
FT 165
FT 165
FT 165
FT 165
FT 215
FT 215
FT 215
FT 215
FT 215
FT 215
FT 265
FT 265
FT 265
FT 265
FT 265
A
b
AA
n
AB
f
AC
g
AD
g1
B
a
BA
m
BB
e
C
w1
CA
w2
D
d
DA
d1
DB*)
E
l
EA
l1
F
u
FA
u1
90
90
100
100
112
112
125
125
125
140
140
140
140
140
160
160
160
160
160
190
190
190
216
216
216
216
216
216
216
254
254
254
254
254
254
254
254
18
18
21
21
23
23
26
26
26
25
25
25
25
25
32
32
32
40
32
50
45
50
50
50
50
50
50
50
50
55
55
55
55
55
55
55
55
110
110
120
120
135
135
152
152
152
167
167
167
167
167
188
188
188
188
224
224
226
224
256
256
256
256
256
256
256
296
296
296
296
296
296
296
296
109
109
124
124
139
139
157
157
157
177
177
177
177
177
196
196
196
196
196
196
217
196
196
258
258
217
258
258
258
258
313
258
313
313
313
313
313
178
199
199
178
199
199
199
214
242
214
242
242
242
242
242
71
71
80
80
90
90
100
100
100
100
100
125
125
125
140
140
140
140
140
140
140
140
140
140
140
140
178
178
178
210
210
210
210
210
254
254
254
42
47
47
55
47
55
47
60
60
60
60
56
60
60
60
86
86
95
95
114
114
124
146
146
150
150
150
150
150
171
171
205
180
180
180
172
180
180
180
180
180
218
218
218
257
257
257
257
257
301
301
301
36
36
40
40
45
45
50
50
50
56
56
56
56
56
63
63
63
63
63
70
70
70
89
89
89
89
89
89
89
108
108
108
108
108
108
108
108
52
52
59
59
78
78
80
102
102
120
120
95
135
135
102
102
136
159
136
129
172
159
159
176
186
173
186
138
186
185
178
135
148
185
142
200
142
9
9
11
11
14
14
19
19
19
24
24
24
24
24
28
28
28
28
28
28
32
28
38
38
38
38
38
38
38
42
42
42
42
42
42
42
42
9
9
11
11
14
14
19
19
19
24
24
24
24
24
28
28
28
28
28
28
32
28
28
32
32
32
38
32
38
38
38
38
38
42
42
42
42
M3
M3
M4
M4
M5
M5
M6
M6
M6
M8
M8
M8
M8
M8
M10
M10
M10
M10
M10
M10
M12
M10
M12
M12
M12
M12
M12
M12
M12
M16
M16
M16
M16
M16
M16
M16
M16
20
20
23
23
30
30
40
40
40
50
50
50
50
50
60
60
60
60
60
60
80
60
80
80
80
80
80
80
80
110
110
110
110
110
110
110
110
20
20
23
23
30
30
40
40
40
50
50
50
50
50
60
60
60
60
60
60
80
60
80
80
80
80
80
80
80
80
80
80
80
110
110
110
110
3
3
4
4
5
5
6
6
6
8
8
8
8
8
8
8
8
8
8
8
10
8
10
10
10
10
10
10
10
12
12
12
12
12
12
12
12
3
3
4
4
5
5
6
6
6
8
8
8
8
8
8
8
8
8
8
8
10
8
10
10
10
10
10
10
10
10
10
10
10
12
12
12
12
Dimensions
Energy saving motors, High efficiency IE2
Three-phase motors with squirrel-cage rotor
Size 56 to 160
with surface ventilation, cooling method IC 411, degree of protection IP 55
Type of construction IM B14 [IM 3601]
Flange dimensions see page 31
W21R 56K2, 4
W21R 56G2, 4
W21R 63K2, 4
W21R 63G2, 4
W21R 71K2, 4, 6
W21R 71G2, 4, 6
IE2-W21R 80K2, 4, 6, 8
IE2-WE1R 80G2
IE2-W21R 80G4, 6, 8
IE2-WE1R 90S2, 4
IE2-W21R 90S6, 8
IE2-WE1R 90L2
IE2-WE1R 90LV4
IE2-W21R 90LV6, 8
IE2-W21R 100S8
IE2-WE1R 100L2
IE2-WE1R 100L4
IE2-WE1R 100LX4
IE2-W21R 100LX6, 8
IE2-WE1R 112MX2
IE2-WE1R 112M4
IE2-W21R 112MV6, 8
IE2-WE1R 132S2T
IE2-WE1R 132SX2
IE2-WE1R 132S4
IE2-W21R 132S6, 8
IE2-WE1R 132M4
IE2-W21R 132M6, 8
IE2-W21R 132MX6
IE2-WE1R 160M2
IE2-WE1R 160M4
IE2-W21R 160M8
IE2-W21R 160M6, MX8
IE2-WE1R 160MX2
IE2-WE1R 160L2
IE2-WE1R 160L4
IE2-W21R 160L6, 8
**) Terminal box left/right
GA
t
GC
t1
H
h
HA
c
HD
p
HD**)
p
HH
A
K
s
K’
s’
L
k
LC
k1
KK Type
AG
x
LL
z
O
r
Hole
pattern
Bl.
Bl.
10.2
10.2
12.5
12.5
16
16
21.5
21.5
21.5
27
27
27
27
27
31
31
31
31
31
31
35
31
41
41
41
41
41
41
41
45
45
45
45
45
45
45
45
10.2
10.2
12.5
12.5
16
16
21.5
21.5
21.5
27
27
27
27
27
31
31
31
31
31
31
35
31
31
41
41
35
41
41
41
41
41
41
41
45
45
45
45
56
56
63
63
71
71
80
80
80
90
90
90
90
90
100
100
100
100
100
112
112
112
132
132
132
132
132
132
132
160
160
160
160
160
160
160
160
7
7
7.5
7.5
8
8
9
9
9
9.5
9.5
9.5
9.5
9.5
11
11
11
18
18
18
15
18
18
15
15
16
16
16
15
18
18
18
18
18
18
18
18
154
154
167
167
182
182
200
200
200
217
217
217
217
217
237
237
237
249
249
249
290
249
287
331
331
310
331
331
331
374
402
374
402
402
402
402
402
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
a.A.
58
58
61
61
67
67
70
70
70
75
75
75
75
75
77
77
77
77
77
77
108
77
96
114
114
108
114
114
114
114
138
138
138
138
138
138
138
6
6
7
7
7
7
10
10
10
10
10
10
10
10
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
15
15
15
15
15
15
15
15
6
6
7
7
7
7
10
10
10
10
10
10
10
10
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
15
20
15
20
20
20
20
20
176
176
199
199
239
239
265
287
287
321
321
321
362
362
357
357
391
421
357
391
459
421
460
481
529
479
529
481
529
605
571
559
571
609
609
667
609
199
199
225
225
273
273
310
332
332
376
376
376
416
416
425
425
459
489
425
459
542
489
528
565
613
562
613
565
613
689
656
643
656
724
724
783
724
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KK 25 A
KA 05
KK Ex
KK 25 A
KK 25 A
KK 25 A
KK 25 A
KK 25 A
KK 25 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
156
92
104
156
156
156
156
156
156
193
193
193
193
193
193
193
193
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
145
92
112
145
145
145
145
145
145
167
167
167
167
167
167
167
167
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M32x1.5
M25x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
14
14
14
14
16
16
16
16
16
18
18
18
18
18
20
20
20
20
20
20
35
20
20
35
35
35
35
35
35
35
35
35
35
35
35
35
35
3
Energy saving motors | Special catalogue 02-2009
Type designation
47
Dimensions
Energy saving motors, High efficiency IE2
Three-phase motors with squirrel-cage rotor
Size 56 to 280
with surface ventilation, cooling method IC 411, degree of protection IP 55
Type of construction IM B5 [IM 3001], Type of construction IM V1 [IM 3011]
Energy saving motors | Special catalogue 02-2009
Flange dimensions see page 31
48
Type designation
Flange
size
AC
g
AD
g1
D
d
DA DB*)
d1
W21R 56K2, 4
W21R 56G2, 4
W21R 63K2, 4
W21R 63G2, 4
W21R 71K2, 4, 6
W21R 71G2, 4, 6
IE2-W21R 80K2, 4, 6, 8
IE2-WE1R 80G2
IE2-W21R 80G4, 6, 8
IE2-WE1R 90S2, 4
IE2-W21R 90S6, 8
IE2-WE1R 90L2
IE2-WE1R 90LV4
IE2-W21R 90LV6, 8
IE2-W21R 100S8
IE2-WE1R 100L2
IE2-WE1R 100L4
IE2-WE1R 100LX4
IE2-W21R 100LX6, 8
IE2-WE1R 112MX2
IE2-WE1R 112M4
IE2-W21R 112MV6, 8
IE2-WE1R 132S2T
IE2-WE1R 132SX2
IE2-WE1R 132S4
IE2-W21R 132S6, 8
IE2-WE1R 132M4
IE2-W21R 132M6, 8
IE2-W21R 132MX6
IE2-WE1R 160M2
IE2-WE1R 160M4
IE2-W21R 160M8
IE2-W21R 160M6, MX8
IE2-WE1R 160MX2
IE2-WE1R 160L2
IE2-WE1R 160L4
IE2-W21R 160L6, 8
IE2-WE1R 180M2
IE2-WE1R 180M4
IE2-WE1R 180L4
IE2-W21R 180L6, 8
IE2-WE1R 200L2
IE2-WE1R 200 LX2
IE2-WE1R 200L4
IE2-W21R 200LX6
IE2-W21R 200L6, 8
IE2-WE1R 225M2
IE2-WE1R 225S4
IE2-WE1R 225M4
IE2-W21R 225S8
IE2-W21R 225M6
IE2-W21R 225M8
IE2-WE1R 250M2
IE2-WE1R 250M4
IE2-W21R 250M6, 8
IE2-WE1R 280S2
IE2-WE1R 280M2
IE2-WE1R 280S4
IE2-WE1R 280M4
IE2-W21R 280S6
IE2-W21R 280S8
IE2-W21R 280M6, 8
FF 100
FF 100
FF 115
FF 115
FF 130
FF 130
FF 165
FF 165
FF 165
FF 165
FF 165
FF 165
FF 165
FF 165
FF 215
FF 215
FF 215
FF 215
FF 215
FF 215
FF 215
FF 215
FF 265
FF 265
FF 265
FF 265
FF 265
FF 265
FF 265
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 300
FF 350
FF 350
FF 350
FF 350
FF 350
FF 400
FF 400
FF 400
FF 400
FF 400
FF 400
FF 500
FF 500
FF 500
FF 500
FF 500
FF 500
FF 500
FF 500
FF 500
FF 500
109
109
124
124
139
139
157
157
157
177
177
177
177
177
196
196
196
196
196
196
217
196
196
258
258
217
258
258
258
258
313
258
313
313
313
313
313
351
351
351
351
351
351
390
390
351
390
390
440
390
440
440
440
490
490
490
490
490
490
490
490
550
178
199
199
178
199
199
199
214
242
214
242
242
242
242
242
261
261
261
261
261
261
300
300
261
300
300
324
300
324
324
358
386
386
386
386
386
386
386
386
416
9
9
11
11
14
14
19
19
19
24
24
24
24
24
28
28
28
28
28
28
32
28
38
38
38
38
38
38
38
42
42
42
42
42
42
42
42
48
48
48
48
55
55
55
55
55
55
60
60
60
60
60
60
65
65
65
65
75
75
75
75
75
9
9
11
11
14
14
19
19
19
24
24
24
24
24
28
28
28
28
28
28
32
28
28
32
32
32
38
32
38
38
38
38
38
42
42
42
42
48
42
48
42
48
48
55
55
48
55
55
55
55
55
55
55
55
55
65
65
65
65
65
65
65
*) Centre holes acc. to DIN 332-DS
M3
M3
M4
M4
M5
M5
M6
M6
M6
M8
M8
M8
M8
M8
M10
M10
M10
M10
M10
M10
M12
M10
M12
M12
M12
M12
M12
M12
M12
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
E
l
EA
l1
F
u
FA
u1
GA
t
GC
t1
H
h
HH
A
L
k
LC
k1
KK Type
AG
x
LL
z
O
-
20
20
23
23
30
30
40
40
40
50
50
50
50
50
60
60
60
60
60
60
80
60
80
80
80
80
80
80
80
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
20
20
23
23
30
30
40
40
40
50
50
50
50
50
60
60
60
60
60
60
80
60
60
80
80
80
80
80
80
80
80
80
80
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
140
140
140
140
140
140
140
3
3
4
4
5
5
6
6
6
8
8
8
8
8
8
8
8
8
8
8
10
8
10
10
10
10
10
10
10
12
12
12
12
12
12
12
12
14
14
14
14
16
16
16
16
16
16
18
18
18
18
18
18
18
18
18
18
20
20
20
20
20
3
3
4
4
5
5
6
6
6
8
8
8
8
8
8
8
8
8
8
8
10
8
8
10
10
10
10
10
10
10
10
10
10
12
12
12
12
14
12
14
12
14
14
16
16
14
16
16
16
16
16
16
16
16
16
18
18
18
18
18
18
18
10.2
10.2
12.5
12.5
16
16
21.5
21.5
21.5
27
27
27
27
27
31
31
31
31
31
31
35
31
41
41
41
41
41
41
41
45
45
45
45
45
45
45
45
51.5
51.5
51.5
51.5
59
59
59
59
59
59
64
64
64
64
64
64
69
69
69
69
79.5
79.5
79.5
79.5
79.5
10.2
10.2
12.5
12.5
16
16
21.5
21.5
21.5
27
27
27
27
27
31
31
31
31
31
31
35
31
31
41
35
35
41
41
41
41
41
41
41
45
45
45
45
51.5
45
51.5
45
51.5
51.5
59
59
51.5
59
59
59
59
59
59
59
59
59
69
69
69
69
69
69
69
56
56
63
63
71
71
80
80
80
90
90
90
90
90
100
100
100
100
100
112
112
112
132
132
132
132
132
132
132
160
160
160
160
160
160
160
160
180
180
180
180
200
200
200
200
200
225
225
225
225
225
225
250
250
250
280
280
280
280
280
280
280
81
81
94
94
97
97
70
70
70
114
114
114
114
114
77
77
77
77
77
77
108
77
96
114
114
108
114
114
114
114
138
138
138
138
138
138
138
147
147
147
147
147
147
168
168
147
168
168
177
168
177
177
177
206
206
206
206
206
206
206
206
211
199
199
232
232
269
269
265
287
287
360
360
360
401
401
357
357
391
421
391
391
459
421
460
481
529
479
529
481
529
605
571
559
571
609
609
667
609
635
680
680
680
680
730
727
727
680
767
757
862
797
862
862
862
924
924
924
970
924
970
970
970
1105
222
222
258
258
303
303
310
332
332
425
425
425
455
455
425
425
459
489
459
459
542
489
528
565
613
562
613
565
613
689
656
643
656
724
724
783
724
751
796
796
796
796
846
851
851
796
891
881
977
921
977
977
977
1042
1042
1072
1118
1072
1118
1118
1118
1273
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KA 05
KK 25 A
KA 05
KK Ex
KK 25 A
KK 25 A
KK 25 A
KK 25 A
KK 25 A
KK 25 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 63 A
KK 100 A
KK 100 A
KK 63 A
KK 100 A
KK 100 A
KK 100 A
KK 100 A
KK 100 A
KK 100 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
KK 200 A
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
156
92
104
156
156
156
156
156
156
193
193
193
193
193
193
193
193
193
193
193
193
193
193
213
213
193
213
213
213
213
213
213
282
282
282
282
282
282
282
282
282
282
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
145
92
112
145
145
145
145
145
145
167
167
167
167
167
167
167
167
167
167
167
167
167
167
207
207
167
207
207
207
207
207
207
242
242
242
242
242
242
242
242
242
242
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M20x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M25x1.5
M32x1.5
M25x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M32x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M40x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M50x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
Hole BI.
pattern Bl
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
8L
8L
8L
8L
8L
8L
8L
8L
8L
8L
8L
8L
8L
8L
8L
8L
14
14
14
14
16
16
16
16
16
18
18
18
18
18
20
20
20
20
20
20
35
20
20
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
40
40
45
40
45
45
45
50
50
50
50
50
50
50
50
55
Dimensions
Energy saving motors, High efficiency IE2
Three-phase motors with squirrel-cage rotor
Size 315
with surface ventilation, cooling method IC 411, degree of protection IP 55
Type of construction IM B5 [IM 3001] up to size 315 MY
Type of construction IM V1 [IM 3011]
Flange dimensions see page 31
Type designation
Flange
size
AC
g
AD
g1
D
d
DA DB*)
d1
IE2-W21R 315S2
IE2-W21R 315M2
IE2-W21R 315MX2
IE2-W21R 315MY2
IE2-W21R 315L2
IE2-W21R 315LX2
IE2-W21R 315S4
IE2-W21R 315M4
IE2-W21R 315MX4
IE2-W21R 315MY4
IE2-W21R 315L4
IE2-W21R 315LX4
IE2-W21R 315S6
IE2-W21R 315M6
IE2-W21R 315MX6
IE2-W21R 315MY6
IE2-W21R 315L6
IE2-W21R 315LX6
IE2-W21R 315S8
IE2-W21R 315M8
IE2-W21R 315MX8
IE2-W21R 315MY8
IE2-W21R 315L6
IE2-W21R 315LX8
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
FF 600
550
550
550
610
610
610
550
550
550
610
610
610
550
550
610
610
610
610
550
550
610
610
610
610
416
416
416
498
498
498
416
416
416
498
498
498
416
416
498
498
498
498
416
416
498
498
498
498
65
65
65
65
65
65
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
65
65
65
65
65
65
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
**) Terminal box right/left
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
E
l
EA
l1
F
u
FA
u1
GA
t
GC
t1
H
h
HH
A
L
k
LC
k1
KK Type
AG
x
LL
z
AH
-
O
r
Bl.
Bl
140
140
140
140
140
140
170
170
170
170
170
170
170
170
170
170
170
170
170
170
170
170
170
170
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
18
18
18
18
18
18
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
18
18
18
18
18
18
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
69
69
69
69
69
69
85
85
85
85
85
85
85
85
85
85
85
85
85
85
85
85
85
85
69
69
69
69
69
69
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
211
211
211
230
230
230
211
211
211
230
230
230
211
211
230
230
230
230
211
211
230
230
230
230
1050
1105
1185
1270
1390
1510
1080
1135
1215
1300
1420
1540
1135
1135
1300
1300
1420
1420
1135
1135
1300
1300
1420
1420
1218
1273
1353
1448
1543
1688
1248
1303
1383
1478
1598
1723
1303
1303
1478
1478
1598
1598
1303
1303
1478
1478
1598
1598
KK 200 A
KK 200 A
KK 200 A
KK 400 B
KK 400 B
KK 400 B
KK 200 A
KK 200 A
KK 200 A
KK 400 B
KK 400 B
KK 400 B
KK 200 A
KK 200 A
KK 400 B
KK 400 B
KK 400 B
KK 400 B
KK 200 A
KK 200 A
KK 400 B
KK 400 B
KK 400 B
KK 400 B
282
282
282
415
415
415
282
282
282
415
415
415
282
282
415
415
415
415
282
282
415
415
415
415
242
242
242
340
340
340
242
242
242
340
340
340
242
242
340
340
340
340
242
242
340
340
340
340
265
265
265
265
265
265
265
265
265
265
265
265
265
265
265
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
M63x1.5
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
Energy saving motors | Special catalogue 02-2009
3
49
Energy saving motors | Special catalogue 02-2009
Notes
50
© 2009 KOMMUNIKATION SCHNELL GmbH
VEM/03-175 E/0309 Printed in the Federal Republic of Germany. Changes are reserved.
VEM motors GmbH
Carl-Friedrich-Gauss-Strasse 1
38855 Wernigerode
Germany
Phone: +49 (0)39 43/68 0
Fax:
+49 (0)39 43/68 24 40
E-mail: motors@vem-group.com
www.vem-group.com

Similar documents

VEM-082792_Katalog 01-2008_Schiffsmotoren_Umschlag_5

VEM-082792_Katalog 01-2008_Schiffsmotoren_Umschlag_5 Electric machines made by VEM have millions of applications around the globe. VEM stands for high-quality products such as large and special-purpose machines, standard motors and customized drives ...

More information

Low voltage asynchronous motors IEC motors with squirrel

Low voltage asynchronous motors IEC motors with squirrel or else have taken over the latter’s stipulations as European standard EN 60034-1. The following permissible temperature rise applies to the standards and regulations specified:

More information

product guide

product guide PRIER has been keenly aware of the lead free legislation and has been closely monitoring this bill with the EPA, ASA Lobby Partners and our certifying laboratories. PRIER has lead free for products...

More information

Elektrim Full - sahabat waskita teknik

Elektrim Full - sahabat waskita teknik Low voltage high-power motors contain terminal boxes with cable gland seals and cable clamps to prevent their removal. Inside the boxes there are special clamps used to ground the supply cable armo...

More information

Katalog - Standardni program gonil

Katalog - Standardni program gonil biti izdelani v ISO H7 toleranci. Za navlačenje elementov (zobniki, verižniki, elastične sklopke, jermenice ipd.) uporabite navoj centrirne izvrtine na vstopni ali izstopni gredi gonila. Element...

More information