OVERVIEW - AMX Solutions, Inc.

Transcription

OVERVIEW - AMX Solutions, Inc.
OVERVIEW
AMX-4 Plus
Signature Series© AMX-4 Plus
2702 Mike Padgett Highway
Augusta, GA 30906
p: (706) 793-2697
f: (706) 793-8051
amxsolutionsinc.com
COMPANY PROFILE
We know that great things happen when you partner with your customers and
solutions come from asking the right questions of the right people. AMX
Solutions, Inc. came into existence as the result of years of intensive research
with Directors of Radiology, Bio Med, Clinical and Field Engineers. We asked
what they saw as the ideal set of circumstances under which they could
streamline work processes, reduce maintenance issues and eliminate downtime.
As in the “Field of Dreams” they told us “you build it . . . we’ll come.” The result
of this research is a combination of services crafted into intelligent solutions to
fulfill all your AMX requirements.
AMX Solutions, Inc. specializes in the GE AMX line of portable x-ray machines.
When you specialize, you’ve got to be good at what you do! With 25 years
experience in the field, we know this product...each model... we are the best in
the industry and we stand 100% behind our work. When you purchase
equipment from AMX, you’re not just buying a portable. You’re buying years of
knowledge and experience built on quality, integrity and total customer
satisfaction. Our specialty is rebuilding and upgrading the AMX 4 with all the
features, functionality and reliability of the AMX 4 Plus. We are dedicated to
helping engineers eliminate downtime. It is our belief that a unit should never be
down for more than 24 hours and our purpose is providing solutions to meet that
goal.
Our company was originally founded in Augusta, Georgia and is comprised of a
well qualified staff with extensive experience working with GE AMX portable
x-ray machines. Our staff of certified engineers and technicians is qualified in
rebuilding units ranging from the CMX to the AMX 4 Plus.
Our 26,000 sq. ft. facility houses state of the art test equipment in individual
assembly stations where the various AMX components and parts are built and
prepared for installation and sale. We stock and extensive inventory of fully
rebuilt portables as well as new, used and rebuilt OEM parts.
As you map out your budget strategies, consider how we can assist you with
your requirements for portable x-ray machines. It will be the best decision you
ever made when it comes to portables.
̧̧̬̥ɳʊʌʆɶʂʅʈʆʕʕɮʊʈʉʘʂʚ
ɧʖʈʖʔʕʂ̡ɭɧ̨̥̮̥̫
ʑ̨̢̧̯̝̬̥̫̞̬̮̫̮̬
ʇ̨̢̯̝̬̥̫̞̬̮̭̥̪̦
amxsolutionsinc.com
ɸɫɨɻɯɲɺɴɵɺɸɫɬɻɸɨɯɹɮɫɪ
You made the right choice years ago when you chose the AMX portable x-ray system and
though it may now be a little worse for the wear, you may be surprised by how much useful
life it still has. Doesn’t it make sense to get all the value out of your AMX system that was built
into it? Our purpose is to rebuild not refurbish GE AMX portable x-ray machines to extend the
life of these units. We rebuild units from top to bottom, inside out and virtually everything in
between proving that there is a world of difference between simply refurbishing and actually
rebuilding your AMX unit.
Each unit is fully rebuilt under the following guidelines to OEM specifications:
ʭɩʐʎʑʍʆʕʆʐʗʆʓʉʂʖʍʐʇʎʆʄʉʂʏʊʄʂʍʂʏʅʆʍʆʄʕʓʊʄʂʍʄʐʎʑʐʏʆʏʕʔ
ʭɹʕʓʖʄʕʖʓʂʍʓʆʊʏʇʐʓʄʆʎʆʏʕʔ
ʭɧʍʍʘʐʓʏʂʏʅʃʓʐʌʆʏʑʂʓʕʔʓʆʑʍʂʄʆʅʘʊʕʉɵɫɳʑʂʓʕʔʊʏʄʍʖʅʊʏʈ̯
ʭɩʐʍʖʎʏ˅̧̬̥˄ɸʐʕʂʕʊʐʏ
ʭɮʐʓʊʛʐʏʕʂʍɧʓʎɸʆʑʍʂʄʆʎʆʏʕ
ʭɩʐʎʑʍʆʕʆʃʂʔʆʂʔʔʆʎʃʍʚʘʊʕʉʎʐʕʐʓʔ̡ʅʓʊʗʆʃʆʍʕʔ̡ʆʕʄʓʆʑʍʂʄʆʅ
ʭɴʆʘʉʂʏʅʔʘʊʕʄʉʘʊʕʉʏʆʘʄʂʃʍʆʄʐʎʑʍʆʕʆʘʊʕʉʓʆʎʐʕʆʇʊʆʍʅʍʊʈʉʕʐʑʕʊʐʏ
ʭɩɶɻ̡ʄʉʂʓʈʆʓʃʐʂʓʅ̡ʆʕʄ̣
ʭɧɳɾ̩ɶʍʖʔɮ̤ɼɩʂʃʍʆʔ
ʭɧɳɾ̩ɶʍʖʔɳʂʊʏɩʂʃʍʆʔ
ʭɴʆʘʔʕʚʍʆʘʊʓʊʏʈʉʂʓʏʆʔʔ
ʭɴʐʊʔʆʔʖʑʑʓʆʔʔʐʓʔ̡ʇʊʍʕʆʓʔ̡ʈʓʐʖʏʅʊʏʈʄʂʃʍʆʔ
ʭɨʂʔʆʂʏʕʊʭʔʕʂʕʊʄʈʓʐʖʏʅʊʏʈʄʂʃʍʆ
ʭɲʂʕʄʉʖʑʈʓʂʅʆ
ʭɩʉʂʔʔʊʔʓʆʊʏʇʐʓʄʆʎʆʏʕ
ʭɸʆʃʖʊʍʕʅʓʊʗʆʎʐʕʐʓ
ʭɴʆʘʄʐʍʍʊʎʂʕʐʓʄʂʃʍʆ
ʭɴʆʘʓʐʕʐʓʄʂʃʍʆ
ʭɩʓʐʔʔʉʂʊʓʘʊʏʅʐʘʓʆʑʍʂʄʆʅ
ʭɴʆʘʂʓʎʍʐʄʌ
ʭɴʆʘʃʖʎʑʆʓʑʂʅʔ
ʭɧʍʍʃʆʂʓʊʏʈʔʊʏʔʑʆʄʕʆʅʂʏʅʓʆʑʍʂʄʆʅʂʔʏʆʄʆʔʔʂʓʚ
ʭɸʆʊʏʇʐʓʄʆʅʄʂʔʔʆʕʕʆʅʓʂʘʆʓ
ʭɳʂʊʏʇʓʂʎʆʄʉʂʔʔʊʔʓʆʊʏʇʐʓʄʆʎʆʏʕʊʏʔʕʂʍʍʆʅʕʐʑʓʆʗʆʏʕʄʓʂʄʌʊʏʈ
ʭɴʆʘʉʐʔʑʊʕʂʍʈʓʂʅʆʄʐʓʅʄʂʑʘʊʕʉʄʐʓʅ
ʭɩʐʎʑʍʆʕʆʔʚʔʕʆʎʄʂʍʊʃʓʂʕʊʐʏʊʏʇʖʍʍʄʐʎʑʍʊʂʏʄʆʘʊʕʉɨɸɮʔʕʂʏʅʂʓʅʔ
ʭɧʍʍʓʆʑʂʊʓʔʂʏʅɵɫɳʓʆʇʊʏʊʔʉʊʏʈ
ʭɩʐʎʑʍʆʕʆʔʆʓʗʊʄʆʅʐʄʖʎʆʏʕʂʕʊʐʏ
ʭɺʘʆʍʗʆʎʐʏʕʉʔʕʆʄʉʏʊʄʂʍʔʖʑʑʐʓʕ
ʭ̧̦ʎʐʏʕʉʑʂʓʕʔʘʂʓʓʂʏʕʚ
ʭ̧̦ʎʐʏʕʉʎʂʏʖʇʂʄʕʖʓʆʓʪʔʇʖʍʍʓʆʑʍʂʄʆʎʆʏʕʘʂʓʓʂʏʕʚʐʏʕʖʃʆ̧̰̦ʎʐʏʕʉʑʓʐʓʂʕʆʅ
warranty on batteries
2702 Mike Padgett Highway
Augusta, GA 30906
p: (706) 793-2697
f: (706) 793-8051
amxsolutionsinc.com
S.W.A.P. (Save With Awaiting Portables)
In keeping with our focus on eliminating down time, we stock an inventory of rebuilt AMX 4 portables
upgraded with all the features of the AMX 4 Plus. Our S.W.A.P. program provides an unparalleled
opportunity to trade your existing AMX 4 portable for a completely rebuilt/upgraded unit that includes
all the features and functionality of the AMX 4 Plus thus allowing you to continue your normal
operations, eliminate equipment shortages, downtime and reduce freight costs.
TECHNICAL SUPPORT 24/7
Our goal is to be available with solutions for your staff when they encounter problems such as
specification issues, error codes and any other issues with your AMX portables that they have
difficulty solving. Our technicians have the solutions when you have a problem and they are available
24 hours a day, 7 days a week, and 365 days a year.
Technical support is provided free with the purchase of one of our rebuilt portables.
OEM PARTS - NEW USED & REBUILT
We can help maintain your AMX portables at substantial discounts with our extensive
inventory of new, used and rebuilt OEM parts for the complete line of GE AMX portables. We stock
an extensive inventory of parts that cannot be found elsewhere and are the source other suppliers
come to for that hard to find item. Our customers can realize
dramatic savings with new or rebuilt OEM parts.
RENTALS / LOANERS PROGRAM
Rental units available for long or short term lease. We also have loaner units available for use while
we rebuild your portable. Contact us for pricing and availability on these programs.
2702 Mike Padgett Highway
Augusta, GA 30906
p: (706) 793-2697
f: (706) 793-8051
amxsolutionsinc.com
PM PACKAGES
Give your GE AMX 4 or 4 Plus portable x-ray unit a new lease on life with a cosmetic make-over
along with your preventative maintenance routine. This is a cost effective way to quickly and efficiently
make your portable look brand new in just a couple of hours. AMX will provide all the major OEM
components assembled and ready to bolt on. The pre-assembled kits also include all original OEM
decals, labels, bumpers and screws. Below is a complete listing of all components for each of the PM
Packages..
DESCRIPTION
Top Cover
Cap Key
Shoulder Screw
#6 Flat Washer
Key Switch
Top Cover Latch
Label Kit
AMX 4 PLUS
46-303626G4
46-303652P2
46-170024P8
6NWSM
46-303993G1
46-279104P1
2201783
QTY
1
1
2
2
1
2
1
AMX 4
46-303626G3
46-279023P1
46-170024P8
6NWSM
46-303652P1
46-279104P1
2201782
QTY
1
1
2
2
1
2
1
FRONT & SIDE COVERS
On Decal
46-279773P1
Off Decal
46-279772P1
Wear Strip 28.8”
46-270782P2
Wear Strip Stiffener
46-270785G2
Batt Charge Warning
46-279022P1
Right Side Cover
46-303785G2
Left Side Cover
46-303784G2
Label Side Cover
2170180
Label Side Cover
2170181
Ball Stud
46-120145P4
Hand Switch Label
46-316783P1
1
1
2
2
1
1
1
1
1
10
1
46-279773P1
46-279772P1
46-270782P1
46-270785G1
46-270785G1
46-303785G1
46-303784G1
1
1
2
2
1
1
1
46-230145P4
46-316783P1
10
1
MISCELLANEOUS COMPONENTS
Cassette Drawer Hdle
46-270729P2
Decal - Hdl/Warning
46-315954P2
Drawer Mat
46-270238P1
Cassette Tray Assy
46-270231G2
1
1
1
1
46-270729P1
46-305954P2
46-270238P1
46-270231G2
1
1
1
1
2702 Mike Padgett Highway
Augusta, GA 30906
p: (706) 793-2697
f: (706) 793-8051
amxsolutionsinc.com
FIRST AID KIT
No more hunting for just the right screw, nut or that amp fuse that always seems to wind up
missing. First Aid kits contain common hardware for your AMX that is designed to save you
time and money by reducing and eliminating down time.
First Aid Kit Includes:
PART #
M3X6
6/32 X 3/8
4/40 X 1/4
10/32 X 3/4
46-268418P1
46-219036P1
46-303376G1
4/40 X 1/4
10/32
10/32 X 1-1/4
46-302409G1
46-279306P1
46-136334P54
06F8228 Q85/Q86
6/32 X 3/8
10/32 X 1
1/4 X 20 X 3/4
1/4 X 20 X 3/8
46-303652P1
46-270799P1
6/32 X 1/2
10/32 X 7/8
WASHERS
46-221914P4
FUSES
46-303993G1
DESCRIPTION
COLLIMATOR COVER SCREWS
SIDE PANEL SCREWS
DRIVE HANDLE COVER SCREWS
CORNER BUMPER SCREWS
POINTER
COLLIMATOR BOLTS
COLLIMATOR HANDLE PARTS
SIDE PANEL SCREWS
SPLASH GUARDS & CPU MOUNTS
COLUMN BRAKE COVER SCREWS
CORNER BUMPER SCREWS
SENSOR ASSY
BRAKE ENABLE SWITCH
DRIVE HADLE MICROSWITCH
FETS
TOP COVER COLLAR SCREWS
HV CABLE CLAMP SCREWS ON ARM
KICKPLATE & TUBE YOKE SCREWS
HV TERMINAL COVER SCREWS
CAP KEY
LIGHT SWITCH
TERMINAL BLOCKS & GROUND STUD SCREWS
HV CABLE CLAMP SCREWS ON COLUMN
BUMPERS, ANGLE BRACKETS, ETC.
BATTERY CHARGE INDICATOR LAMP
2, 6, 8, 10 & 15 AMP (1 BOX EACH)
KEY SWITCH
̧̧̬̥ɳʊʌʆɶʂʅʈʆʕʕɮʊʈʉʘʂʚ
ɧʖʈʖʔʕʂ̡ɭɧ̨̥̮̥̫
ʑ̨̢̧̯̝̬̥̫̞̬̮̫̮̬
ʇ̨̢̯̝̬̥̫̞̬̮̭̥̪̦
amxsolutionsinc.com
ɺɫɩɮɴɯɩɧɲɺɸɧɯɴɯɴɭ
Portable x-ray units are one of the most predominantly used and misused machines in the medical
field. Due to the very nature of their environment, they can experience mechanical and electrical
failures if problems are not recognized and corrected quickly. Upon completion of this course,
participants will be able to successfully troubleshoot and repair the most common problems
encountered by these indispensable units as well as perform preventative maintenance to ensure
proper functionality.
Prior to receiving a Certificate of Completion, participants will understand and be able to evaluate the
following:
ʭɧʔʔʆʎʃʍʚɪʆʔʊʈʏʂʕʐʓʔ
ʭɺʉʆʇʊʗʆʎʐʅʆʔʕʐʕʉʆʔʆʓʗʊʄʆʔʘʊʕʄʉ
ʭɳʂʋʐʓʄʓʊʕʊʄʂʍʔʊʈʏʂʍʔ
ʭɬʖʔʆʔ
ʭɸʐʕʐʓʄʐʏʕʓʐʍʔ
ʭɨʂʕʕʆʓʊʆʔ̡ʄʉʂʓʈʆʓʂʏʅʄʂʑʂʄʊʕʚ
ʭɯʏʗʆʓʕʆʓ
ʭɪʓʊʗʆʎʐʕʐʓʄʐʏʕʓʐʍ
ʭɩʐʍʍʊʎʂʕʐʓ
ʭɵʗʆʓʂʍʍʔʚʔʕʆʎʑʆʓʇʐʓʎʂʏʄʆ
ʭɺʓʐʖʃʍʆʔʉʐʐʕʂʏʅʓʆʑʂʊʓʎʆʄʉʂʏʊʄʂʍʂʏʅʆʍʆʄʕʓʐʏʊʄʑʓʐʃʍʆʎʔʐʏʂʍʍ
components of the unit
ʭɶʆʓʇʐʓʎʂʄʐʎʑʍʆʕʆʂʏʅʕʉʐʓʐʖʈʉʑʓʆʗʆʏʕʊʗʆʎʂʊʏʕʆʏʂʏʄʆʊʏʔʑʆʄʕʊʐʏ
ʭɬʐʍʍʐʘʄʊʓʄʖʊʕʐʑʆʓʂʕʊʐʏʔʐʇʔʚʔʕʆʎʅʆʕʂʊʍʃʍʐʄʌʅʊʂʈʓʂʎʔ
ʭɫʗʂʍʖʂʕʆʆʓʓʐʓʄʐʅʆʔʂʏʅʕʂʌʆʄʐʓʓʆʄʕʊʗʆʂʄʕʊʐʏʔ
Course Prerequisites
Participant must have a working understanding of state-of-the-art electronics, test equipment and
mechanical aptitude. Previous experience with X-ray aparatus is required.
2702 Mike Padgett Highway
Augusta, GA 30906
p: (706) 793-2697
f: (706) 793-8051
amxsolutionsinc.com
TECHNICAL TRAINING
This comprehensive, five-day course provides hands on training dedicated to teaching participants to
quickly recognize and correct common problems. The first three days are spent disassembling and
reassembling an AMX 4 Plus portable focusing on the major components listed below:
COLUMN
(Disassemble and reassemble)
Sh e l l I n n e r we a r s t r i p s
Carriage Carriage wear
strips
Carriage bearings
Counter weight
Counter weight bearings
Upper / lower braking
Main and safety cable
tensions Detente plates
Bearing packing
Apron hanger
COLLIMATOR
Co l l i m a t o r a l i g n m en t
Sid tape
Co l u m n l i g h t
Cr o s s h a i r wi n d o w
Face plate
Release handles
Column handle
Column cable
Column knobs
HORIZONTAL ARM
(Disassemble and reassemble)
Inner, center, outer covers
Wear strips
Tracking chain and gear
Locking plunger
Latch holder
Yolk
Détente bearings
Compression washers
Inner brake cable
X-RAY TUBE
P r o p e r a sse mb l y
C o ve r s
HV Cables
Alignment of collimator
Rotor cable
Tracking serial numbers
End caps
BASE
D r i ve mo t o r
ELECTRONIC PACKAGE
Frame
Power supply
CPU board
Drive boards
MA & KV board
Rotor board
Cord reel
Latch assembly
Hand switch
TRANSFORMER
Connectors
Oils
Gasket replacement
BASE
D r i ve mo t o r
D r i ve w h e e l s
Mounting brackets
Drive belts
Proper grounding
Column support (tub)
Front bumper
Switches
Corner bumper pads
Installation of batteries
Casters
Belt tension springs
Day four is devoted to theory of operation and day five is dedicated to running diagnostics, calibration,
understanding error codes and troubleshooting common problems. Class size is limited to six
participants.
Schedule and order of criteria is subject to change depending upon enrollment.
Five CEU Credit Equivalents earned upon completion of class.
Application
The AMX-4+ X-ray unit is a completely
t Large front casters (20.3cm / 8 in.)
t Fully counterbalanced collimator/tube
for easier crossing of thresholds
assembly, with the center of gravity
(e.g. elevator), expansion joints.
self contained battery driven, mobile
radiographic system which operates
from a rechargeable battery pack.
at points of rotation, so tube stays
positioned through light friction locks
t Narrow base of unit measures
60.2 cm (29.7 in.) wide at midpoint.
without the need for adjustable locks.
Detents at ±90º for both axes.
Mobility and ease of use make the AMX-4+
ideally suited for all routine radiographic
t Capable of climbing an incline of 5°.
procedures, within intensive care units,
expose and the collimator light. The
handswitch is molded from a light-
emergency and operating rooms,
pediatrics, neonatal units, orthopedics,
and clinics.
Operator Ease of Use
t Unique column rotation in clockwise
or counterclockwise direction from
Features
Maneuverability
t Independent rear wheel drive servo-
t Ergonomic handswitch controls prep/
weight, impact-resistant plastic.
t Compact manual collimator with
the park position significantly
built-in SID button-on collimator face.
increases setup speed by eliminating
Skin spacer is provided to meet BRH
the need to reposition the patient or
requirements of 30cm focal spot to
the system. The column may be
skin minimum distance. Rotary knobs
rotated up to ±270º from the park
adjust field size with calibrations at
controlled motors enable the system
position to handle the most demand-
100 cm and 180 cm (40 in. and 72 in.)
to turn within its own radius.
ing imaging cases in tight spaces.
A positive centering detent is also
t Electromechanical friction locks for
provided to further simply the tube
column rotation, arm elevation and
parking
parking process
process.
a
arm
rm extension
extension movements
movements. Locks
Locks
are released with a single switch on
collimator.
t Integrated front bumper stops unit
and activates brakes when hit. Sides
of bumper slide into unit to prevent
catching on objects such as cords,
poles, etc.
Base Assembly
t Two position ON/OFF key switch with
removable key in the OFF position.
t Single drive handle control (with
"deadman" brake and drive lock)
t Touch panel or handswitch activated
functions ergonomically with drive
technique selection; two point (kVp
motors to permit superior
and mAs) control.
maneuverability. Drives respond to
t Digital readout of kVp and mAs in two
force applied to handle in both
forward and reverse.
locations:
-Angle of Top cover--1.9 cm (3/4 in.),
t Top speed of 4.8 kph (3 mph) in
Column Assembly
forward and reverse.
t Handle grips on both sides of
t Speed totally variable in both reverse
and forward.
t Top speed is limited to 2.4 kph
(1.5 mph) if tube is not in transport
always on when ready for exposure.
-Message display--0.95 cm (3/8 in.),
when making selection.
collimator for single-hand positioning
of tube. Lock release buttons which
t Forty-eight segment bar graph
activate all lock releases
indicates battery charge status (i.e.,
simultaneously at the back of the
power remaining). Message center
handles.
displays "RECHARGE RECOMMENDED"
1
position.
power remaining, exposure is in-
at 10% power remaining. At 0%
(see Product Data Sheet D1046).
side covers for servicing.
hibited, but will drive before all power
is cut off. Message display will read
t 43 cm x 43 cm coverage at 100 cm
"RECHARGE IMMEDIATELY X-RAY
SID (17 in. x 17 in. coverage at 40
INHIBITED."
inch SID).
t All displays are blue vacuum
t Generator is closed loop kVp design
fluorescent; readable in high ambient
using microprocessor regulation to
light such as surgical suites.
assure constant and accurate kVp at
all battery conditions.
t Positive tube arm extension lock for
transport position prevents tube from
sliding out during transport.
t mAs integrator measures, actual mA
to insure accuracy, reproducibility
and station-to-station linearity of all
t large 30.5 cm (12 in.) drive wheels
exposures.
within protective enclosures will not
mark walls.
t Efficient medium frequency mobile
generator operates at 1,000 Hz and
t Side molding extends the entire length
of cabinet.
provides exceptional battery power
utilization.
AMX-4 Plus
t Collimator field light can be activated
from collimator or handswitch.
t All units capable of 110 or 220 V
nominal 50 or 60 Hz charger operation.
t Digital microprocessor control with
Operates until rotor is prepped. On
service diagnostic software includes
time is programmable between 5 - 45
self-check program, initiated at
seconds.
t Audible tone and light on control
panel indicates X-RAY ON.
Batteries
t Batteries are sealed lead -acid
requiring no maintenance over normal
expected life or five years. Batteries
start-up.
t Calibration software reduces
installation time and time to repair.
are "minimal liquid," film electrolyze
t Apron hanger on column.
technology that will not leak, even if
damaged.
t Message readout displays selfdiagnosed errors on top panel.
t Cassette storage of ten (10) 35 cm x
43 cm cassettes.
t All units capable of 110 or 220 V
nominal, 50 or 60 Hz charger operation;
t Storage tray on top cover holds pens,
lead markers and tape.
t High reliability dome switches for
technique selection (mAs, kVp).
requiring no extra parts except wall
plug.
t Heavy duty welded steel mechanical
chassis for extended life
t 20,000 mAs usable battery power
Generator
Performance/Tube
t 0.75 mm focal spot (NEMA); 3 inch
storage.
t Tube column support includes
integrated wear strips and high
t Automatic battery voltage sensor
strength column base casting with
rotating anode; GE X-ray tube model
protects batteries from deep-discharge
oversized bearings for improved
HRT09.
and thereby prevents permanent
durability.
battery damage.
t 275,000 HU anode heat storage
capacity.
t Tube arm latch supports arm in all
Reliability, Durability and
Serviceability
t 15º target angle.
relief of column while transporting
units over floor imperfections such as
t Modular electrical chassis design for
t Low-speed (3000 rpm) operation only
three dimensions for safety and stress
ease of service.
elevator thresholds or hall expansion
joints.
2
t Motor drives are belt driven using
advanced high technology belts for
Batteries
t Type Sealed lead acid "Minimal
t mAs
long-life operation. Belt mounting
kVp
facilitates easy removal installation.
Range
mAs
classifies battery as dry. Cannot
50-90
0.4-320
leak if punctured
95-105
0.4-240
110-125
0.4-200
Specifications
AMX-4 Plus Unit Consists Of:
liquid" or film electrolyte technology
t Pack Nine 12-volt packs connected
All in 25% increments, 20%
in series (10 V nominal). Runs both
decrements
motor drive and X-ray from same
pack.
t Control, Microprocessor
t mA 100 mA nominal
t High-Tension Transformer
t Digital readouts, blue vacuum
t Unit is shipped with batteries fully
charged.
fluorescent.
t Top 1.9 cm (3 4 in.) kVp and mAs.
Battery Charging System
t Automatic battery status sensing with
t Message 0.95 cm (3 in.) all
programmed overcharging protocol for
message.
maximizing battery life.
t Battery Status 0.95 cm (3 in.) bar
t Charger cord provided with retraction
graph.
into base. Hospital grade line plug fits
standard wall receptacle.
t Switches are dome-type
yp p
push
s
l
sP
buttons under mylar cover.
t Maximum line draws 5 A, 110 V;
2.5 A, 220 V.
t On Off Two Position Switch
-Off Remove ey
t High-Voltage Cables
-Off
t Rotating Anode X-ray Tube
The drive System and X-ray work
t Unit designed to be charged in any
-On
corridor or room space with normal
ventilation. Unit should not be charged
in closets, etc., or in areas using
t only in ON position. Charger works
t Collimator
in either position.
t Base and Cabinet
Handswitch controls the rotor prep,
isolated power, e.g., surgery.
t Charger operates in any key switch
position as charger mode has
t exposure and remote field light.
precedence over all other modes
t Tube Stand
(transport exposure). The system
Audible Tone X-ray On
t Motor Drive
can neither be moved, nor used for
t
X-ray if it is recharging. Charger
Generator
t Batteries
status displayed on message
t
readout.
requency 1,000 Hz
t Battery Charging System
t
t Operational and Diagnostic Software
t
Voltage 50 to 125 kVp
Power 12.5 k
Mechanical Dimensions
t Overall idth (includes front bumper)
nominal
63.9 cm (25 in.).
t
Technical Control
t kVp 50 to 76 in 2 kVp steps
t kVp each or 150 kVp for pair.
0 to 125 in 5 kVp steps
ederal type connectors.
Cables Vinyl covered, rated to 75
t
idth at Midpoint 60.2 cm (23. in.).
t Overall Height 193 cm (76 in.).
decrease normal film optical density.
t Tube Height In (transport look over)
3