DosPrint - Hanskamp
Transcription
DosPrint - Hanskamp
DosPrint Type 1825 Installation and operating instruction Article number: 1840 Date: August 2014 Version 5.1 - Translation of Original Instructions for use According to Annex 1 chapter 1.7.4 Machine guideline 2006/42/EG Doetinchem, The Netherlands www.hanskamp.nl EN DosPrint EN Type 1825 Preface Manual Contents This manual contains the information necessary for the correct installation and operation of a HanskampDosPrint. Study and understand this information thoroughly before configuration of the DosPrint. Failure to do so could result in damage to equipment. Please consult your milking equipment dealer if you do not understand the information in this manual, or if you need additional information. All information in this manual has been compiled with care. Hanskampshall not be liable for errors or faults in this manual. The recommendations are meant to serve as guidelines. All instructions, pictures and specifications in this manual are based on the latest information that was available at the time of publication. Your DosPrint may comprise improvements, features or options that are not covered in this manual. Applicability The table below shows the type numbers of the DosPrint for which this manual is applicable. Model designation Model Typenumber DosPrint 1825 Contact number Local Service Provider We suggest you write the name, address and telephone number of your local service pro-vider contact in the table below. This makes sure you can easily find the information. Name Adress Telephone number E-mailadress 2 - 14 Hanskamp AgroTech B.V. (the Netherlands) www.hanskamp.nl/en DosPrint EN 1. Type 1825 Introduction The ingenious DosPrint ensures that the motor control makes the feeding jack go back one turn after dosing. This makes DosPrint a very solid alternative for sensitive and complex spilling valves. Because DosPrint is tailor-made, it can be linked to almost all brands of feeding stations. The system also fits Hanskamp AgroTech's CrisyDos and Black V as well as DeLaval's automated V system. The information in this manual is for farmers and technicians. Dairy farmers use the information to test and adjust the DosPrint or to list overviews. Technicians use the information to install and setup the DosPrint. 3 - 14 Hanskamp AgroTech B.V. (the Netherlands) www.hanskamp.nl/en DosPrint EN Type 1825 2. Safety 2.1 Introduction The safety alert symbol identifies important safety messages on your DosPrint and in the manual. When you see this symbol, be alert to the possibility of personal injury or death. Follow the instruction of the safety message. Safety Alert Symbol 2.2 Signal Words Note the use of the signal words DANGER, WARNING and CAUTION with the safety messages. The signal word for each message uses the following guidelines: Warning! Indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury, and includes hazards that are exposed when guards are removed. Danger! Indicates a imminently hazardous situation that, if not avoided, will re -sult in death or serious injury. 2.3 Safety Instructions YOU are responsible for the SAFE operation and maintenance of your DosPrint. YOU must make sure that you and anyone else who is going to operate, maintain or work in the vicinity of the DosPrint knows all the related SAFETY information in this manual. YOU are the key to safety. Good safety practices protect you and the people around you. Make these practices a working part of your safety program. Make sure EVERYONE who operates, maintains or works near the DosPrint obeys the safety precautions. Do not risk injury or death by ignoring good safety practices. DosPrint owners must train operators before they operate the DosPrint. This training must be repeated at least annually. The operator must read, understand and obey all safety and operating instructions in the manual. A person who has not read and understood all safety and operatinginstructions is not permitted to operate the DosPrint. Do not modify the equipment in any way. Unauthorized modification may impair the function and/or safety and could affect the life of the equipment, and persons. Only use approved spare parts, and make sure they are only installed by authorized technicians. 4 - 14 Hanskamp AgroTech B.V. (the Netherlands) www.hanskamp.nl/en DosPrint EN Type 1825 2.3.1 General Safety Read and understand the manual and all safety signs before you connect power supplies to operate, maintain or adjust the DosPrint. Only trained persons are permitted to operate the DosPrint. A first-aid kit must be available near the DosPrint. Store in a highly visible place. A carbon dioxide or foam fire extinguisher must be available near the DosPrint. Store the fire extinguisher in a highly visible place. Install all protective covers and guards before you operate the DosPrint. Wear the correct protective clothing and equipment. Disconnect and isolate the electrical power supply before you clean or do maintenance on the DosPrint. Know the emergency medical centre number for your area. Contact your nearest milking equipment dealer provider if you have any questions Review safety related items with all operators frequently (annually). 2.3.2 Electrical Safety Only an authorized electrician must install the electrical power supply for the DosPrint. Make sure the electrical grounding of the electrical system and all parts of the DosPrint meet the local rules and regulations. Replace any damaged electrical lines, conduits, switches and components immediately. Isolate the electrical power supply before you open the DosPrint to work on the electrical system. 2.3.3 Installation Safety Read and understand the instructions in this manual. Make sure the DosPrint is correctly installed. 2.3.4 Operating Safety Read and understand the applicable manual and all safety signs before you connect power supplies to operate, maintain or adjust the DosPrint. Only trained persons are permitted to operate the DosPrint. Switch off the electrical power supply by taking plug out of the power point and secure the plug before you clean or do maintenance on the DosPrint. Install the covers and guards before you operate the DosPrint. Keep hands, feet, hair and clothing away from all the electrical parts. Keep unauthorized persons, especially small children away from the DosPrint at all times. Before the electrical supply is attached to the DosPrint, make sure all parts are tight and that all the parts are in good condition. Contact your nearest milking equipment dealer if you have any questions. 5 - 14 Hanskamp AgroTech B.V. (the Netherlands) www.hanskamp.nl/en DosPrint EN Type 1825 2.3.5 Maintenance Safety Read and understand the applicable manual and all safety signs before you connect power supplies to operate, maintain or adjust the DosPrint. Only trained persons are permitted to maintain the DosPrint. Switch off the electrical power supply by taking plug out of the power point and secure the plug before you clean or do maintenance on the DosPrint. Wear protective clothing and safety goggles when you do work on the pneumatic system. Make sure all the covers and guards are installed when maintenance work is complete. 2.3.6 Safety Decals General safety messages appear in this safety messages section. Specific safety messages are in applicable parts of this manual when potential hazards may occur if the instructions or procedures are not followed. 6 - 14 Hanskamp AgroTech B.V. (the Netherlands) www.hanskamp.nl/en DosPrint EN Type 1825 Control print synchronic motor The DosPrint is a unique control which prevents residual trickling in feed stations by making the auger run in reverse direction after dispensing. This control is also perfectly applicable for milking parlour feeding. The extensive possibilities make this control applicable to numerous installations. We supply DosPrint in two types of our feeders, but for DeLaval feeding stations it is also possible to mount just the DosPrint between Station Controller and the feeder. Specifications DosPrint: Power supply 24VAC (brown and white) Input 12-24VAC-DC (blue and grey) Power output (not specified) Output potential-free contact <1Ω (red and black) Output for 24VAC synchronous motor L/R on. (red,white and 2x blue) 22μF capacitor on the circuit board. Push button and 2 x 8 digit display Glass fuse 1A Display During normal operation nothing is shown on the display. The print's program goes through several process steps which are displayed in code on the display after pushing the button: 10 No action 11 Pulse active motor turns counter-clockwise 12 “ot” Motor time Pulse not active, motor turns counter-clockwise (not with “Cr”) “dt” Delay time Pulse not active, wait time “oE” Motor Extra-time. Pulse not active, motor turns counter-clockwise in extra float time “or” Motor return. Pulse not active, motor in float time, clockwise 13 14 15 During the configuration of the DosPrint, the matching setting possibilities are indicat ed in code. If the button is not pushed for 30 minutes, the display will automatically switch off. Push button By using the push button, settings can be viewed or changed. 1. Push the button. The operating mode appears. 2. Push the button again, which calls up the setting range. 3. If the button is pushed once more, the next setting range will appear. 4. If the setting for this range needs to be displayed, keep the button depressed until the screen starts flashing. 5. Browse through the setting possibilities by briefly pressing the buton. - Then save the setting (press the button until the screen starts flashing) -abort the setting procedure (press the button until the display turns off) Look at page 4 for the complete menu structure. Look at page 5 for the default menu structure. 7 - 14 Hanskamp AgroTech B.V. (the Netherlands) www.hanskamp.nl/en DosPrint EN Type 1825 Operation: Cr: Contact reed: Every 10 sec motor turning time (11) “oC” contact high 1 second. (imitating reed-switch) Cn: Contact normal: Contact is 1800msec high, then low for 200msec. (sleep contact normal) Ci: Contact inverse: Contact is low 1800msec, then high for 200msec. (sleep contact inverted) it: internal test: Program for testing inputs and outputs. 00 is low 01 is high. DosPrint in CrisyDos and Black V Feeding station with CrisyDos and DosPrint 1 Feeding station with Black V and DosPrint 2 PipeFeeder with DosPrint 3 DosPrint in the motor housing 4 8 - 14 Hanskamp AgroTech B.V. (the Netherlands) www.hanskamp.nl/en DosPrint EN Type 1825 Display shows function code. 10 Co ot dt oE or i t Cr Contact reed; Functions as reed switch (DeLaval) Cn Contact normal; Break contact (VC3 Nedap) Ci Contact inverted; Make contact (VC4 Nedap) 12 Motor time; Minimum turning time, 0299 not in menu “Cr” 13 Delay time; Waiting time after last pulse in sec: 00-99 14 Motor Extra time; Set in sec: 00 – 99 default: 02 15 Motor return; Idling stroke time in sec: 00 - 19 default:02 oL output Left, test motor counterclockwise (normal) or output Right, test motor clockwise (return) oC out Contact, test potential- free contact (reed/i-contact) i P input Pulse Test input. DP Display Program Show program version. Press button briefly Press button until screen starts flashing 9 - 14 Hanskamp AgroTech B.V. (the Netherlands) www.hanskamp.nl/en DosPrint EN Type 1825 menu Cr iP Display 11 13 14 11 14 11 14 13 11 11 13 15 14 13 15 Motor Function Diagram DosPrint Time Setting advice per brand/model feed computer Feeding stations CrisyDos DosPrint Co ot dt oE or Remarks Black V Yes Cr 0 20 02 05 Feeding stations DosPrint Co Ot Dt oE Or Remarks (DosPrint-version) version 3.0 (DosPrint-version) version 2.4 In-parlour-feeding Yes Cr 0 20 02 02 Yes Cr 0 20 00 02 Default settings Version 3.0 is supplied from July 2014 Version 2.4 is supplied until July 2014 DosPrint Co ot dt oE or Remarks PipeFeeder Yes Cr 0 0 02 02 Nedap VC3 Yes Cn 10 50 0 5 Prom with “R” or resistance 48Ω parallel over M+ and Mx Nedap VC4 en ISO Yes Ci 10 50 0 5 resistance 48Ω parallel over M+ and Mx DeLaval Alpro ‘V automaat’ Yes Cr 0 20 0 5 Use Black V with DosPrint. DeLaval ‘happy’ - - - - - - Use Black V with DosPrint see setting for DeLaval Alpro GM (ID2000 en GM3000) Yes Cr 0 20 0 5 in combination with CrisyDos. BouMatic Yes Cr 0 20 0 5 in combination with CrisyDos and 470Ω resistance parallel Fullwood Yes Cr 0 20 0 5 in combination with CrisyDos. The settings by version 2.4 and 3.0 are not rexchangeable. Look for your version on page 9, display program. DosPrint can only be used in combination with a 24VAC synchronous motor which uses a 22μF condensator. Consult the installation instructions of the concerned feeding computer or milking parlour feeding for connections and settings. DosPrint is perfectly suited for the Hanskamp PipeFeeder, CrisyDos and Black V. More info: www.hanskamp.nl/en 10 - 14 Hanskamp AgroTech B.V. (the Netherlands) www.hanskamp.nl/en DosPrint EN Type 1825 5 Synchronous motor connection 2x8 dig. display Potential-free contact. (reed switch or I contact) Feed computer pulse. 12-24 VAC/VDC 24VAC Power Fuse 1A Push button Power outlet 24VAC Revision Table of software version DosPrint Date: Aug 2010 Jan 2011 May 2011 Version: 2.0 2.1 2.2 Approved: Nov 2011 2.3 Improved pulstime. No delaytime of 200 mSec on every feed signal. More accurate (especially on Feed2) July 2013 2.4 Default settings adapted. July 2014 3.0 Default settings adapted in Fullwood in combination with Pipefeeder. OT 14 after first pulse, not after Dt. Co-Cr oT-0 dT-20 oE-02 or-02 First approved version Default settings addapted. Co-Cr dT-20 oE-0 or-5 Adaption delay time: 200 mSec To prevent shortcuts of the outlet Revision Table of instruction version Date: Version: Approved: Aug 2010 Jan 2011 May 2011 0 1 2 First approved version Adaption of DosPrint settings. Adaption of DosPrint settings. Nov 2011 July 2013 3 4 Adaption of DosPrint settings. Adaption of DosPrint settings (new version) July 2014 August 2014 5 5.1 Adaption of DosPrint settings. New name and logo added 11 - 14 Hanskamp AgroTech B.V. (the Netherlands) www.hanskamp.nl/en DosPrint EN Type 1825 Warranty limitations: The warranty excludes costs and expenses due to: incorrect use of the equipment, not in accordance with the specifications in the instructions for installation and use; the consequences of any intervention by engineers other than engineers recognised and approved by Hanskampfor carrying out service, maintenance and other technical work; incidents such as freezing, ice, fire, flooding, inundation or any other form of extreme water damage, and lightning; defects in the electrical system or earthing system; use of compressed air that does not meet the quality standards of Hanskamp AgroTech; damage to the electrical system due to vermin and so forth. The warranty is not applicable to consequential damage that is not related to the machine itself. All systems have been tested. However, in the event of faults, Hanskampcannot be held responsible for consequential damages. Copyright and disclaimer The information given in this publication is provided for information purposes only and does not constitute an offer for sale. The products supplied may differ from those illustrated. No part of this publication may be reproduced or made public without prior permission in writing from Hanskamp AgroTech BV. Although this publication was put together with the utmost care, Hanskamp AgroTech is not liable for any damage that might arise due to errors or gaps in this publication. The instructions for installation and use in Dutch are the original instructions for installation and use. The translations into other languages have used the Dutch instructions for installation and use as the source document. Hanskamp AgroTech does not accept any liability for differences between the translations. If there are doubts about the content and accuracy of the translated instructions for installation and use, the Dutch instructions for installation and use constitute the authoritative document. 12 - 14 Hanskamp AgroTech B.V. (the Netherlands) www.hanskamp.nl/en DosPrint EN Type 1825 Declaration of incorporation of completed machinery IIA (According to annex VIIA of machine directive 2006/42/EC, for completed machinery) We, Hanskamp AgroTech BV Arendsenweg 7 7021 PC Zelhem The Netherlands Authorised compiler(s) of the technical dossier: H.J. Hanskamp State, entirely under their own responsibility, that the product: 1825 DosPrint Synchroon-motor PCB to which this declaration pertains, does meet the stipulations of the following directive(s): Machine Directive 2006/42/EC and completely or partially meets the following essential requirements and that the relevant technical documents were drawn up in accordance with Annex VIIA. The product also complies with the stipulations in the following annex(es): NEN-EN-ISO 12100 NEN-EN-ISO 4414 NEN-EN-IEC 60204-1 NEN-EN-IEC 13849-1 We call your attention to the fact that where a DosPrint closing gate has not been installed or has not been installed in accordance with safety measures in these installation and operating instructions, this declaration of stipulations is null and void and so no rights can be derived from this declaration. The Netherlands, Zelhem 16-06-2014 H.J. Hanskamp 13 - 14 Hanskamp AgroTech B.V. (the Netherlands) www.hanskamp.nl/en DosPrint EN Type 1825 Hanskamp Broekstraat 17 7009 ZB Doetinchem The Netherlands Tel: +31 (0)314 - 393 797 Fax: +31 (0)314 - 393 826 www.hanskamp.nl Visit us on: 14 - 14 Hanskamp AgroTech B.V. (the Netherlands) www.hanskamp.nl/en