Aquavista 500R Fuse Replacement Procedure

Transcription

Aquavista 500R Fuse Replacement Procedure
Aquavista 500R Fuse
Installation Instructions
WARNING!!! ALWAYS TURN OFF THE POWER AND UNPLUG
THE AQUARIUM BEFORE SERVICING
*Please read the instructions thoroughly before you perform service*
Recommended Fuse
1. 3 Amp, 250v AC,Fast Blow
Recommended Tools Needed:
1. Middle size Philips head screwdriver
2. Small size Flat head screwdriver
Step 1
Make sure the power cord is unplugged and
the tank is off.
Now remove the frame from the aquarium as you
would do so normally.
1
Step 2
Locate the round blue sticker which can be found
at the top right hand corner of the tank.
Remove the screw that is located behind the round
blue sticker using a small size flathead screwdriver.
Step 3
The side panel is located on the same side as
the LCD screen and keypad.
A
You can now remove the side panel by placing your
screwdriver in the crack located at the top of the
aquarium’s side panel.
B
Step 4
Now gently push down roughly ½ inch and the panel
should come off. The side panel where the LCD screen
and keypad are located will be attached to the circuit
board so be careful not to pull too hard on the cords
when removing the side panel.
2
Step 5
Unplug the 2 connectors from the LCD and keypad
to the circuit board.
You should now have the LCD screen and keypad
free from the rest of the circuit board and aquarium.
Fuse Location
White cord to white
circuit board
Black cord to black
circuit board
Step 6
Replace the fuse by taking out the fuse housing.
(3.15A/250v fast blow fuse)
Step 7
Reconnect the LCD and keypad, and fit
the control panel back to the aquarium
by sliding it up roughly ½ inch.
3
Step 8
If everything is connected properly and the
power cord is free of any water splashes,
you may plug the power cord in and reset
the clock on the control panel.
Thank You for Your Time and Patience!
4