Condensing High Efficiency Domestic Water Heaters, Pool Heaters
Transcription
Condensing High Efficiency Domestic Water Heaters, Pool Heaters
FFC-7 Condensing High Efficiency Domestic Water Heaters, Pool Heaters and Boilers Fully Condensing – Ultra Efficient The gas-fired Futera Fusion Series brings the field-proven performance of RBI boilers and water heaters to the ultimate levels of efficiency and reliability. Fusion’s innovative design makes it the ideal choice for applications with low operating, return or make-up water temperatures. Unlike most condensing products on the market today which publish the highest efficiencies at the lowest inputs, the Fusion Series can attain efficiencies as high as 99% at full input! The fully modulating firing system continuously varies the energy Premium Performance & Superior Reliability input to precisely match the heating load without over-firing and • 99% Maximum Efficiency wasting fuel providing extremely high part-load efficiencies. • Full Modulation up to (5:1 Fusion XLF / 4:1 Fusion) • Sealed Combustion/Direct Vent If you’re looking to maximize operating efficiency, reliability, and • Symmetrically Air/Fuel Coupled flexibility in domestic hot water and hydronic heating applications, • Commercial Combustion Controls the Fusion Series is your heating solution. • Linked Operating Control System for Multiple Unit Applications • Gasket-less Heat Exchanger Assembly Features and Benefits • 500 – 2000 MBH (Fusion) Optional Features • 2500 – 4000 MBH (Fusion XLF) • BACnet or LonWorks Interface Module • Copper 4-Pass Heat Exchanger (160 PSI) • Cupro-nickel Finned Tubes • Stainless Steel Secondary Heat Exchanger • Freeze Protection Package • PVC & Polypropylene (PP) Venting • Honeywell Keyboard Display Module S7800 • HeatNet Integrated Boiler Control Platform • Outdoor Sensor with Housing • Modulating Temperature Control Mixing Valve • Outdoor Installation • Variable Speed Blower • Knockdown Ready (Fusion XLF) • Flame Safeguard • Knockdown Available (Fusion) • Category II & IV Venting • Flow Switch (Mounted & Wired) • Integral Primary Pump • Service Friendly Design Up To 99% • Pool Heating In the interest of product improvement, RBI reserves the right to make changes without notice. 2 Advanced Heat Exchanger Technology The Fusion’s heat exchanger was designed using the most efficient Smart Service Design and dependable heat transfer materials available today. The Large capacity in a small footprint offers greater flexibility and (boiler) or bronze (water heater) and finned copper or cupronickel ease of installation in a space-saving design that leaves more tubing for superior heat transfer, resistance to scaling, and elbowroom in the mechanical room. The rugged structural steel protection against thermal shock. low-mass, gasket-less primary heat exchanger has solid cast iron base is designed to fit through a standard 30" doorway. A variety of venting options provides added installation flexibility. Quick- The condensing secondary heat exchanger is solid stainless release latches allow for easy access to all components to make steel and designed to operate at the boiler’s full flow rate. It short work of service and maintenance. operates in full condensing mode at all times, while a state of the art temperature mixing system protects the boiler’s primary The Turbo Pilot®: Reliability At Its Best heat exchanger. Each Fusion carries a full non-prorated 20 year The Futera Series independent “Turbo-Pilot” system with UV This design also offers a larger heat transfer surface area than any detection is far more durable and reliable than any competitive competitive product currently available. This ignition system available today. translates into the highest available -efficiencies warranty against damage from condensate or thermal shock. There’s simply no better way to protect an owner’s investment. – at full operating input! We challenge you to At 8,000 btu’s the “Turbo-Pilot” provides look closely at competing products’ efficiency a sure-fire source for burner ignition while data. No other water heater or boiler on the providing continuous performance feedback market has full input efficiencies as high as the through the HeatNet control platform. Fusion’s. 3 Symmetric Air/Fuel Coupling Fusion Series units operate safely and efficiently at all times by reacting to changes in the air or fuel flow which can compromise combustion. Air/Fuel coupling automatically adjusts to any changes in the environment by reducing input levels to maintain optimum combustion quality while providing the highest degree of safety. Air/Fuel coupling further increases application flexibility by allowing installation of Fusion units in areas of variable air inlet and gas pressures without compromising safety or performance. Advanced gas train design monitors and regulates gas input based on combustion air pressure, which in turn provides highly repeatable air/fuel ratio throughout the operating range. Space-saving Footprint The compact footprint of Futera Fusion boilers allows for multiple boiler installations while conserving valuable boiler room space for ease of service and maintenance access. 4 IGNITION STATUS FUSION OPERATION STATUS BACK SELECT POWER ON OFF Intelligence Built In HeatNet, RBI’s proprietary integrated boiler management system, is the driving force behind RBI’s energy optimization philosophy for its high-efficiency equipment. HeatNet is designed for precise system control and is standard on all Futera Series boilers. Through continuous monitoring of several system characteristics, including boiler temperatures, limit circuit inputs, and overall system demands, HeatNet modulates boiler firing rates to maximize turndown ratios to maintain peak efficiency regardless of the load. Versatile In addition to maintaining peak efficiency in our stand-alone boilers, HeatNet can operate as part of a multi-boiler Master/ inputs. Boiler firing rotations can be programmed for First On/First Member network of up to 16 boilers, where typical Master/Member Off, First On/Last Off or “True Rotation.” HeatNet also modulates systems using 2, 3, 4 or 5 boiler configurations can see total the local boiler pump for Primary/Secondary systems, ensuring turndown ratio of 8, 10, 12, 15, 20 or even a maximum of over optimum boiler Delta T. 28:1* depending on the number of units in the application. Straightforward HeatNet can also function as a boiler management system, HeatNet’s intuitive interface, with plug-and-play connections, incorporating a mix of both condensing and non-condensing speeds the installation, set-up, and diagnostic process for boilers, or in base-load applications with existing boilers, technicians. HeatNet’s electronics are conveniently located in a eliminating the need for costly additional third-party, wall-mounted self-contained control enclosure, with all internal components and control platforms. terminal blocks easily accessible. The standard HeatNet control uses a Modbus protocol with optional protocessor boards for HeatNet “learns” the optimal firing rates of a given application, BACnet- and Lon Works-based building management systems. Its thereby determining the system’s load for maximum energy proprietary design allows for seamless flash drive or laptop-driven efficiency. The variable control settings for Mod/Max firing rates updateable firmware, adding continuous value and boiler system allow technicians to adjust the maximum firing rates, enabling control without physical control platform updates that can make all boilers to run at extremely efficient levels until all units in some equipment obsolete. the sequence have fired. HeatNet keeps the firing rate as low as possible, taking advantage of increased efficiencies at lower *Total turndown ratio's based on multiple units linked in a master/member configuration controlled through HeatNet. 5 Ø10" AIR INLET 48 7/16 (1230mm) 9 7/16 (240mm) Fusion XLF 4000 Top View 29 1/8 (740mm) 31 1/8 (791mm) Ø3" SUPPLY 2" NPT GAS TRAIN Ø3" INLET 69" (1753mm) 46 13/16 (1189mm) Ø10" EXHAUST FLUE 39 3/16 (995mm) 24 3/8 (619mm) 15" (381mm) 3/4" NPT DRAIN OUTLET CONDENSATION DRAIN 9 11/16 (246mm) 84" (2134mm) 14 9/16 (370mm) 3/4" NPT CONDENSATION DRAIN OUTLET Side View Back View Models CB = Boiler CW = Water Heater Futera Fusion XLF — Dimensions and Ratings* Flue Vent Cat IV Positive (Up to 60') Cat II UL Listed Stainless PVC/PP Size MBH kW MBH kW Steel Option Negative 2500 733 2350 689 8" 8" Common 2500 3000 879 2820 826 8" 8" Vent 3000 3500 1026 3290 964 10" 10" Engineered 3500 4000 1172 3760 1102 10" 10" Systems** 4000 * Ratings reflect boilers only. For boiler efficiency information please visit www.ahridirectory.org. ** Diameters may vary based on system design. Input Output Shipping Weight Connections Air Intake 8" 8" 10" 10" Gas 1½" 1½" 2" 2" Water 3" 3" 3" 3" Lbs 2330 2384 2614 2726 Kg 1057 1081 1186 1236 Futera Fusion XLF — Delta T/Boiler Recovery Table - Fahrenheit Size Inlet Temp (°F) 60 80 100 120 140 2500 Flow Rate (gph) 2794 3316 4203 5903 10457 3000 ∆t (°F) 105 85 65 45 25 Flow Rate (gph) 3171 3717 4617 6250 9804 3500 ∆t (°F) 111 91 71 51 32 Flow Rate (gph) 3700 4337 5386 7292 11438 4000 ∆t (°F) 111 91 71 51 32 Flow Rate (gph) 4228 4956 6156 8334 13072 ∆t (°F) 111 91 71 51 32 Futera Fusion XLF — Delta T/Boiler Recovery Table - Celsius Size Inlet Temp (°C) 16 27 38 49 60 6 2500 Flow Rate (l/h) 10560 12536 15886 22314 39529 3000 ∆t (°C) 58 47 36 25 14 Flow Rate (l/h) 11987 14051 17452 23627 37058 3500 ∆t (°C) 62 51 39 28 18 Flow Rate (l/h) 13984 16393 20360 27564 43234 4000 ∆t (°C) 62 51 39 28 18 Flow Rate (l/h) 15982 18735 23269 31502 49411 ∆t (°C) 62 51 39 28 18 19 7/8 (505mm) Fusion 2000 Ø12" AIR INTAKE (Ø305mm) 31 1/8 (791mm) 1 1/2 NPT GAS TRAIN 2 1/2 NPT SUPPLY 69" (1753mm) 60 1/2 (1537mm) 2 1/2 NPT INLET 50 3/4 (1289mm) 41 1/4 (1048mm) 24 7/8 (632mm) 13 3/8 (340mm) 14 9/16 (370mm) 1/2 NPT DRAIN OUTLET CONDENSATE DRAIN Side View Models CB = Boiler CW = Water Heater 5 9/16 (141mm) Back View Futera Fusion — Dimensions and Ratings* Input Output Flue Vent Cat IV Positive (Up to 60') UL Listed Stainless PVC/PP Steel Option 7" 8" 7" 8" 7" 8" 8" 8" 8" 8" 10" 10" 10" 10" Cat II Shipping Weight Connections Size MBH kW MBH kW Negative 500 147 476 139 500 Common 750 220 713 209 750 Vent 1,000 293 952 279 1000 Engineered 1,250 366 1189 348 1250 Systems** 1,500 440 1430 419 1500 1,750 513 1668 489 1750 1,999 586 1904 558 2000 * Ratings reflect boilers only. For boiler efficiency information please visit www.ahridirectory.org. ** Diameters may vary based on system design. Air Intake 8" 8" 8" 10" 10" 12" 12" Gas 1" 1" 1-1⁄4" 1-1⁄4" 1-1⁄4" 1-1⁄2" 1-1⁄2" Water 2" 2" 2" 2-1⁄2" 2-1⁄2" 2-1⁄2" 2-1⁄2" Lbs 875 900 1000 1257 1350 1440 1500 Kg 397 408 454 570 612 653 680 Futera Fusion — Delta T/Boiler Recovery Table - Fahrenheit Size Inlet Temp (°F) 60 80 100 120 140 500 Flow Rate (gph) 614 753 999 1513 3336 750 ∆t (°F) 96 76 56 36 16 Flow Rate (gph) 833 998 1268 1770 3072 1000 ∆t (°F) 106 86 66 46 26 Flow Rate (gph) 1050 1245 1546 2083 3321 1250 ∆t (°F) 112 92 72 52 32 Flow Rate (gph) 1460 1768 2293 3320 6354 1500 ∆t (°F) 101 81 61 41 21 Flow Rate (gph) 1664 2000 2530 3532 6130 1750 ∆t (°F) 106 86 66 46 26 Flow Rate (gph) 1859 2205 2758 3737 6026 2000 ∆t (°F) 111 91 71 51 31 Flow Rate (gph) 2118 2520 3136 4247 6855 ∆t (°F) 111 91 71 51 31 Futera Fusion — Delta T/Boiler Recovery Table - Celsius Size Inlet Temp (°C) 16 27 38 49 60 500 Flow Rate (l/h) 2322 2846 3777 5718 12609 750 ∆t (°C) 53 42 31 20 9 Flow Rate (l/h) 3148 3773 4792 6690 11612 1000 ∆t (°C) 59 48 37 26 14 Flow Rate (l/h) 3968 4707 5844 7873 12552 1250 ∆t (°C) 62 51 40 29 18 Flow Rate (l/h) 5517 6683 8669 12551 24016 1500 ∆t (°C) 56 45 34 23 12 Flow Rate (l/h) 6289 7561 9563 13350 23172 1750 ∆t (°C) 59 48 37 26 14 Flow Rate (l/h) 7028 8336 10427 14126 22777 2000 ∆t (°C) 62 51 39 28 17 Flow Rate (l/h) 8007 9527 11852 16054 25913 ∆t (°C) 62 51 39 28 17 7 Futera Fusion Series Efficiency (Water Heaters & Boilers) 99 97 Low Efficiency 95 High 93 91 89 87 85 60 80 100 120 140 Return Water Temp (°F) 95.1% is AHRI Certified Product Performance Thermal Efficiency 97% Is AHRI Certified Product Performance Combustion Efficiency Performance values based on 500MBH boiler Official AHRI Certified Performance Ratings 260 North Elm Street, Westfield, MA 01085 Tel. (413) 568-9571 Fax (413) 568-9613 7555 Tranmere Drive, Mississauga, Ontario L5S 1L4 Tel. (905) 670-5888 Fax (905) 670-5782 www.rbiwaterheaters.com
Similar documents
Untitled
500 – 1999 MBH Copper 4-pass heat exchanger (160 PSI) Stainless steel secondary heat exchanger PVC & Polypropylene (PP) Venting HeatNet Integrated Boiler Control Platform Modulating Temperature Con...
More information