HIMAP+HICAM (їµ)PDF
Transcription
HIMAP+HICAM (їµ)PDF
HIMAP & HICAM We build a better future! CONTENTS HIMAP HICAM Characteristics ・・・・・・・・・・・ 04 Display ・・・・・・・・・・・・・・・ 10 Characteristics ・・・・・・・・・・・ 30 Display ・・・・・・・・・・・・・・・ 32 Connection Diagram ・・・・・・・・ 34 View & Dimension ・・・・・・・・・ 35 Power Management System Using HIMAP & HICAM(HIPMS) ・・・・・・ 12 Setting Range ・・・・・・・・・・・ 14 Connection Diagram ・・・・・・・・ 18 Terminal Block Pin Specification ・・・25 Characteristic Curve ・・・・・・・・ 26 Order Form ・・・・・・・・・・・・ 28 View & Dimension ・・・・・・・・・ 29 Hyundai Intelligent Measuring & Protection Device Hyundai Intelligent Communication & Measuring Device Protection Relay Function Event Record Function Fault Wave Record Function Circuit Breaker Remote Control Function Communication Function Measuring Function Hyundai Intelligent Measuring & Protection Device HIMAP is a multifunctional digital protection relay that has a protection function to protect incoming and feeder lines, the motor and the transformer. It also has various kinds of measuring functions to check synchronization and a communication function for the Power Management System(HIPMS) to supervise operating conditions. 1 Easy Installation and Maintenance HIMAP is designed with a removable case so that the external electric lines can be connected to the inner part for easy installation and maintenance. 2 Use of a Digital Filter HIMAP uses a digital filter, which prevents any harmonic effects from the high frequency on the power line. 3 Self-diagnosis Function HIMAP has a self-diagnosis function set to observe any system failures, send an alarm signal, and display it on the VFD window. HIMAP | Hyundai Intelligent Measuring & Protection Device | Characteristics ▶ Excellent operating characteristics using a 32 bit microprocessor. ▶ Easy to operate using an interactive menu system. ▶ Easy to connect monitoring system & local computer using four communication channels. ▶ Increased reliability using a self-diagnostic function. ▶ Designed for operator’s convenience. Fault / Event Recording Function HIMAP saves fault events up to 100. Each event data has a fault phase, pick up ratio, operating time and fault date. Also, for the latest fault, HIMAP saves a fault wave which is 300 cycles with the resolution 36 sampling / cycle. This can be transfer to monitoring system by communication port. Circuit Breaker Remote Control Function HIMAP remotely controls circuit breakers by means of the command from SCADA Systems and controls the load of power in the computer through RS-485 communication port. If there is interfacing with another company’s monitoring system, it is easy to connect both systems because our communication control device provides various interface ports and protocols. ◀06 | 07▶ Harmonic Analysis Function ▶ Harmonic contents(1st~11th) for three phase current can be measured. (THD, TDD) ▶ Harmonic contents for three phase fault wave can be analyzed using HIMAP manager program. Vector Diagram +90° a c c▼ 180° 0° 1a = 3.56 ∠ 181.85° 1b = 3.53 ∠ 352.31° 1c = 3.57 ∠ 183.83° Vab = 0.23 ∠ 260.47° Vbc = 0.22 ∠ 259.81° Vca = 0.16 ∠ 260.56° -90° Harmonic Analysis 100.0 1a 1b 1c THD(0) = 68.90(%) 80.0 1CPU 60.0 THD(1) = 69.57(%) 40.0 20.0 THD(2) = 68.63(%) 0.0 2 3 4 5 6 7 8 9 10 11 HIMAP | Hyundai Intelligent Measuring & Protection Device | Characteristics Protection Relay Function Model Protection Object HIMAP–FI Incoming Feeder Relay Function •OCR(50/51) •OCGR(50G/51G) •DGR(67G) •SGR(67G) •OVR(59) •OVGR(64) •UVR(27R/27M/27S) •PSR(47P/47N) Motor HIMAP–M HIMAP-T HIMAP-SC Transformer Syncro-Check •Closing/Trip coil supervision(94)(Option) •OCR(50) •51LR •THR(49) •NSR(46) •NCHR(66) •UCR(37) •OCGR(50G/51G) •DGR(67G) •SGR(67G) •DFR(87M) •Closing/Trip coil supervision(94)(Option) •DFR(87T) •OCR(50/51P)✽ •OCGR(50G/51G) •DGR(67G) •SGR(67G) •Closing/Trip coil supervision(94)(Option) •SCR(25) •OCR(50/51S)✽ •UVR(27) ※ HIMAP-T Type has 2 OCRs. P means primary and S means secondary. Measuring Function HIMAP has a measuring function as shown in the below table. It displays the value of each measurement on the VFD window by operating a menu key and then transfers and displays the data on the HIMIX window, which has an outside digital indicator connected by a communication cable. Various kinds of measuring values are converted to a primary value by input of a CT/PT ratio and then displayed on the VFD window. Measuring Display Accuracy (%) 0~999999 V ±0.5 Current(Ir, Is, It, Io, Ips, Ins, Iavg, ITHD, ITDD) 0~999999 A ±0.5 Real Power 0~99999999 kW ±0.5 Reactive Power 0~99999999 kvar ±1.0 Apparent Power 0~99999999 kVA ±1.0 Accumulated Real Energy 0~99999999 kWh ±1.0 Accumulated Reactive Energy 0~99999999 kvarh ±1.0 Power Factor -1.0~1.0 PF ±0.5 Power Voltage(Vrs, Vst, Vtr, Vo, Vps, Vns, Vavg, Vomax) Frequency 45~65 Hz ※ CT/PT ratio will be set by using relay control keys and then displayed via VFD window. The values will be saved at flash memory even though the power line will be off. ±0.01 Hz ◀08 | 09▶ Communication Function HIMAP has four communication ports. RS-485 ports transfer all information related to relay operation status, measuring information, and operation status of circuit breakers. This information is then perceived by HIMAP and sent to communication control device at the speed of 62.5 K bps, using RS-485 HDLC frame protocol and NRZI mode of synchronous communication. The communication control device connects a master PC to the Power Management System (HIPMS) at the speed of 10M bps by Ethernet, TCP/IP. Please refer to the HIPMS manual for details on the monitoring function. HIMIX communication port transfers kinds of measuring values optional to HIMIX at the speed of 9600 bps. The external port of HIMAP transfers the fault record from a site to the PC for analysis, changes the relay element value to a correct one, and is an RS-232C communication port to monitor the status of all kinds of protection relay. Interface with SCADA Communication Control Device Type of Communication Protocol HiCM860S Ethernet Modbus / TCP HiCM-PC RS-232, 422, 485 Modbus / RTU HIMAP | Hyundai Intelligent Measuring & Protection Device | Display Front View Display Window(VFD) Internal Case Exterior Case System Status Indicator CB Status (Normal Operation, System Fail, Fault) CB Control Display Key Input Key Select Switch & Led RS232 Port Movement Key Set ACK ◀10 | 11▶ Specification Item Rating Accuracy Temperature Insulation Resistance Voltage Withstand Overland Withstand 사양 Current 1 A or 5 A, Burden : Below 0.1 VA/Phase Voltage 110 V or 190 V, Burden : Below 0.3 VA/Phase Frequency 50 Hz or 60 Hz Measuring ±0.5 % Protection Relaying ±2 % Operation Guarantee -10 ℃ ~ 55 ℃ Restoration Guarantee -25 ℃ ~ 70 ℃ Circuits-Ground 10 MΩ Between Circuits 5 MΩ Between Contacts 5 MΩ Power Frequency AC 60 Hz 2000 V/1 Min Lightning Impulse 1.2/50 ㎲ 5 kV Current Circuit Rating Current × 3 : 3 hours / Rating Current × 20 : 2 sec Voltage Circuit Rating Voltage × 3 : 3 hours Control Power Rating Voltage × 1.3 : 3 hours Control Power Interruption Maximum 300 ms Control Power AC/DC 95 V ~ 250 V 50/60 Hz Standards IEC 60255 / KEMC 1120 / IEC 61000-4 Communication Type RS-485 Multi Drop Protocol HD-BUS / DNP 3.0 Size 202.5 (W) × 156 (H) × 251.5 (D) Weight 4.5 kg I / O Point Item Input Point Remark AI Voltage 4 Default AI Current 4 Default DI 5 Default DO 7 Default(R1~R7) (21~34) Output 31, 32(R6) : Remote CB On 33, 34(R7) : Remote CB Off HIMAP | Hyundai Intelligent Measuring & Protection Device | Power Management System Using HIMAP & HICAM (HIPMS) System Configuration Remote HIPMS Station To Wide and Local Area Networks Enterprise Management Network Maintenance Management System Router HIPMS Server Operator Station Operating Management System Redundant Ethernet Network 10/100Mbps(Fiber Optic) FEP HICM-860S or HICM-PC HICM-860S or HICM-PC HICM-860S or HICM-PC HICAM Net-MPM HR-256 Module(RTU) HRC-Net Module(RTU) Max 32 Nodes Display Configuration Fault Analysis Network Status System Configuration Remote Setting Alarm System Diagram Report Menu HIMAP Menu ◀12 | 13▶ Alarm Printer Graphic Panel External System Network Report Printer Graphic Driver Color Hard Copler HICM-860S or Gateway Web Server HICM-PC HIMAP HIMIX Web Client Max 32 Nodes S/S SWGR Configuration HIMAP Detail Trend Trend Report Point Report Regular Report Web Client HIMAP | Hyundai Intelligent Measuring & Protection Device | Setting Range FI Type Mode OCR (50/51) OCGR (50G/51G) UVR (27R) UVR (27M) UVR (27S) 47P POR 47N OVR (59) OVGR (64) DGR (67GD) SGR (67GS) Current Inverse, Very Inverse, Extremely Inverse Definite Instant (0.2~2.4) × In (Time Delay) (0.1 A Step) (1~18) × In (0.1 A Step) Time Below 0.05 sec 0.05~10.0 sec (0.01 sec Step) 0.05~10.0 Tap (Time Delay) (0.01 Step) Mode Instant Definite Inverse, Very Inverse, Extremely Inverse Current (0.02~1.0) × In (Time Delay) (0.1 A Step) (0.1~12) × In (0.1A Step) 0.05~10.0 sec (0.01 sec Step) 0.05~10.0 Tap (Time Delay) (0.01 Step) - Definite - - (0.2~0.5) × Vn (0.1 V Step) - Time - 0.1~10.0 sec (0.1 sec Step) - Mode - Definite - Voltage - (0.5~1.0) × Vn (0.1 V Step) - Time - 0.1~10.0 sec (0.1 sec Step) - Mode - Definite - Voltage - (0.5~1.0) × Vn (0.1 V Step) - Time - 0.1~10.0 sec (0.1 sec Step) - Mode - Definite - Voltage - (0.5~1.0) × Vn (0.1 V Step) - Time - 0.1~10.0 sec (0.1 sec Step) - Mode - Definite - Voltage - (0.02~0.5) × Vn (0.1 V Step) - Time - 0.1~10.0 sec (0.1 sec Step) - Mode - Definite Inverse Voltage - Time - Mode Instant Time Below 0.05 sec Mode Voltage (1.1~1.45) × Vn (0.1 V Step) 0.1~10.0 sec (0.1 sec Step) 0.05~10.0 Tap (Time Delay) (0.01 Step) - Inverse Voltage (0.11~0.5) × Vn (0.1 V Step) Time Below 0.05 sec Mode Definite Current (0.04~0.4) × In (0.1 A Step) Voltage (0.1~0.2) × Vn (0.1 V Step) Time 0.1~10.0 sec (0.1 sec Step) Angle 10°~ 45°(1°Step) Mode Definite Current 1~10 mA (0.1 mA Step) Voltage (0.1~0.2) × Vn (0.1 V Step) Time 0.1~10.0 sec (0.1 sec Step) Angle 45°~75°(1°Step) ※ - In: Rating Current, Vn: Rating Voltage - Example HIMAP Setting; In: 5 A, OCR: (1~18)×In → 5~90 A - 0.05~10.0 Tap (Time Delay) (0.01 Step) ◀14 | 15▶ M Type Thermal Current (0.1~1.2) × In (0.1 A Step) THR Cold Limit 0.5~180 sec (0.1 sec Step) (49) Hot Limit 0.5~180 sec (0.1 sec Step) τc/τh 0.1~20 (0.1 Step) Start Current (0.2~14.4) × In (0.1 A Step) Start Time 1.0~60.0 sec (0.1 sec Step) Rocked Rotor Current (0.2~6.0) × In (0.1 A Step) Rocked Rotor Time 1.0~4.0 sec (0.1 sec Step) 51LR Mode OCR (50) Current Instant Time MPR Below 0.05 sec Mode Instant Current (0.1~4.0) × In (0.1 A Step) Time Below 0.05 sec Mode Definite UCR Maximum Current (0.04~0.5) × In (0.1 A Step) (37) Minimum Current (0.04~0.5) × In (0.1 A Step) Time 0.1~10.0 sec (0.1 sec Step) Mode Definite Current (0.1~0.5) × In (0.1 A Step) Time 0.1~10.0 sec (0.1 sec Step) Allow Time 1~60 min (1 min Step) Number of Start 1~16 Limit Time 1~60 min (1 min Step) Thermal Limit(θd) 40~100% (1% Step) 50H NSR (46) NCHR (66) Mode 87M Current Instant Mode (50G/51G) DGR (67GD) SGR (67GS) 0.05~10.0 sec (0.01 sec Step) Definite (0.04~0.4) × In (0.1 A Step) Time OCGR Definite (0.2~18) × In (0.1 A Step) Below 0.05 sec Instant Current Definite (0.1~12) × In (0.1 A Step) Time Below 0.05 sec Mode Definite 0.05~10.0 sec (0.01 sec Step) Current (0.04~0.4) × In (0.1 A Step) Voltage (0.1~0.2) × Vn (0.1 V Step) Time 0.1~10.0 sec (0.1 sec Step) Angle 10°~45°(1°Step) Mode Definite Current 1~10 mA (0.1 mA Step) Voltage (0.1~0.2) × Vn (0.1 V Step) Time 0.1~10.0 sec (0.1 sec Step) Angle 45°~75°(1°Step) ※ - In: Rating Current, Vn: Rating Voltage - Example HIMAP Setting; In: 5 A, OCR: (1~18)×In → 5~90 A 0.05~10.0 sec (0.01 sec Step) Inverse, Very Inverse, Extremely Inverse (0.02~1.0) × In (Time Delay) (0.1 A Step) 0.05~10.0 Tap (Time Delay) (0.01 Step) HIMAP | Hyundai Intelligent Measuring & Protection Device | Setting Range T Type Mode Instant Prim. Current (0.2~1.2) × In (0.1 A Step) Sec. Current (0.2~1.2) × In (0.1 A Step) Inst. Ratio 500~1500% (1% Step) DFR Diff. Ratio 20~50% (1% Step) (87T) Bias Ratio 20~50% (1% Step) 2nd Harmonic Ratio 10~30% (1% Step) TR Type Dy1, Dy11, Yd1, Yd11, ……………, Dd0, Yy0 Zero Comp. Enable, Disable Time Below 0.05 sec Mode Instant OCRP (50P/51P) OCRS (50S/51S) OCGR (50G/51G) DGR (67GD) SGR (67GS) Current Definite (1~18) × In (0.1 A Step) Inverse, Very Inverse, Extremely Inverse (0.2~2.4) × In (Time Delay) (0.1 A Step) Time Below 0.05 sec 0.05~10.0 sec (0.01 sec Step) 0.05~10.0 Tap (Time Delay) (0.01 Step) Mode Instant Definite Inverse, Very Inverse, Extremely Inverse Current (1~18) × In (0.1 A Step) (0.2~2.4) × In (Time Delay) (0.1 A Step) Time Below 0.05 sec 0.05~10.0 sec (0.01 sec Step) 0.05~10.0 Tap (Time Delay) (0.01 Step) Mode Instant Definite Inverse, Very Inverse, Extremely Inverse Current (0.1~12) × In (0.1 A Step) Time Below 0.05 sec Mode Definite Current (0.04~0.4) × In (0.1 A Step) Voltage (0.1~0.2) × Vn (0.1 V Step) Time 0.1~10.0 sec (0.1 sec Step) Angle 10°~45°(1°Step) Mode Definite Current 1~10 mA (0.1 mA Step) Voltage (0.1~0.2) × Vn (0.1 V Step) Time 0.1~10.0 sec (0.1 sec Step) Angle 45°~75°(1°Step) 0.05~10.0 sec (0.01 sec Step) ※ - In: Rating Current, Vn: Rating Voltage - Example HIMAP Setting; In: 5 A, OCR: (1~18)×In → 5~90 A (0.02~1.0) × In (Time Delay) (0.1 A Step) 0.05~10.0 Tap (Time Delay) (0.01 Step) ◀16 | 17▶ SC Type 25A 25B Mode Definite Time 0.1~15.0 sec (0.1 sec Step) Voltage (0.02~0.7) × Vn (0.1 V Step) Phase 0°~100°(1°Step) Frequency 0.01~5.0 Hz (0.01 Hz Step) Mode Definite Time 0.1~15.0 sec (0.1 sec Step) Voltage (0.02~0.7) × Vn (0.1 V Step) Phase 0°~100°(1°Step) Frequency 0.01~5.0 Hz (0.01 Hz Step) Mode Definite Voltage (0.5~1.0) × Vn (0.1 V Step) Time 0.1~10.0 sec (0.1 sec Step) UVR (27S) HIMAP | Hyundai Intelligent Measuring & Protection Device | Connection Diagram HIMAP-FI(3CT, 3PT) R S T R1 PT / GPT 21 9 22 DISPLAY 10 11 R2 23 12 13 24 14 R3 Relay CPU 15 16 26 R4 Output 27 28 GPT 3rd CB Programmable 25 R5 29 1 30 2 R6 31 3 50 4 5 CT 51 6 7 32 R7 33 34 50G 8 Local/ Remote CB On Local/ Remote CB Off 35 NA 51G 36 27 37 CCS 38 47P Option 39 R S T DC 24 V 2 50 52a CT 40 41 42 64 43 44 4 5 47N 59 1 3 TCS 52b 51 67G 46 6 Remote 47 52 Vp 7 ZCT NA 45 8 DI1 DI2 Power 61 63 P N FG RS485 (Scada) 64 KEYBOARD 65 Vp Vn Control 60 62 54 59 When using ZCT (SGR) Vn 53 48 66 67 RS485 (HIMIX) 68 Option ◀18| 19▶ HIMAP-FI/M(2CT, 2PT) R S T R1 PT × 2 21 9 22 DISPLAY 10 11 R2 23 12 13 24 14 R3 Relay CPU 15 26 R4 16 Programmable 25 Output 27 28 CB R5 29 1 30 2 R6 31 3 50 4 5 CT 51 6 7 32 R7 33 34 50G 8 Local/ Remote CB On Local/ Remote CB Off 35 ZCT NA 51G 36 27 37 CCS 38 47P Option 39 R S T DC 24 V TCS 47N 40 59 50 52a 41 42 64 43 44 52b 51 67G NA 45 46 Remote 47 52 Vp DI1 DI2 Vn 53 61 63 P N FG RS485 (Scada) 64 KEYBOARD 65 Vp Vn Power 60 62 54 59 Control 48 66 67 RS485 (HIMIX) 68 Option HIMAP | Hyundai Intelligent Measuring & Protection Device | Connection Diagram HIMAP-M R S T R1 PT / GPT 21 22 9 DISPLAY 10 11 R2 23 12 13 24 14 R3 Programmable 25 Relay CPU 15 16 R4 Output 27 28 GPT 3rd CB 26 R5 29 30 1 2 R6 31 3 MPR 4 5 CT 32 R7 33 (50H / 6 34 7 8 49 / 35 51LR / 36 Local/ Remote CB On Local/ Remote CB Off NA 37 46 / CCS 38 37 / DC 24 V 50 R S 52a T 1 2 52b 51 Remote 66) 40 50 41 50G 43 51G 45 6 42 44 52 67G Vn DI1 53 48 60 61 62 63 7 ZCT DI2 54 8 59 Control Power P N FG RS485 (Scada) 64 KEYBOARD 65 Vp Vn When using ZCT (SGR) NA 47 Vp 5 CT TCS 46 3 4 Option 39 66 67 RS485 (HIMIX) 68 Option ◀20 | 21▶ HIMAP-M(87M)(Self-balancing Type) R S T R1 21 1 DISPLAY 2 3 22 R2 23 4 24 5 CT CPU 6 R3 Programmable 25 Relay 7 26 8 R4 Output 27 28 R5 29 9 30 10 MPR 11 12 31 (50H / 13 CT R6 32 R7 14 33 49 / 34 15 16 GPT 3rd 51LR / 35 46 / 36 Local/ Remote CB On Local/ Remote CB Off NA 37 37 / CCS 38 DC 24 V 52a 52b Remote R S 66) Option 39 TCS 87M 40 50 41 50G 43 51G 45 50 51 52 42 44 T 46 1 DI1 53 67G 47 2 Vp 3 Vn 4 DI2 54 8 Power When using ZCT (SGR) P N FG RS485 (Scada) 65 Vn 7 Control 61 64 KEYBOARD Vp ZCT 60 63 59 6 48 62 5 CT NA 66 67 RS485 (HIMIX) 68 Option HIMAP | Hyundai Intelligent Measuring & Protection Device | Connection Diagram HIMAP-M(87M)(Differential Type) R S T R1 21 1 DISPLAY 2 3 22 R2 23 4 24 5 CT CPU 6 R3 Programmable 25 Relay 7 26 8 R4 Output 27 9 10 28 11 R5 29 12 30 13 14 MPR R6 31 15 (50H / 16 R7 17 33 49 / 18 34 19 CT 32 20 51LR / 35 46 / 36 Local/ Remote CB On Local/ Remote CB Off NA 37 37 / CCS 38 DC 24 V 52a 52b Remote 66) Option 39 TCS 87M 40 50 41 50G 43 51G 45 50 51 52 42 44 NA 46 DI1 53 67G 47 Vp Vn DI2 54 61 63 65 Vp Vn P N FG RS485 (Scada) 64 KEYBOARD Power 60 62 59 Control 48 66 67 RS485 (HIMIX) 68 Option ◀22 | 23▶ HIMAP-T R S T R1 21 22 DISPLAY CB R2 23 1 24 2 3 R3 4 CT Relay CPU 5 6 Programmable 25 26 R4 Output 27 28 R5 29 30 TR R6 31 87T 50P 7 32 R7 33 8 51P 9 50G 11 12 13 NA 36 51G 37 50S 38 CCS 14 15 16 CB Local/ Remote CB Off 35 10 CT 34 Local/ Remote CB On Option 39 51S TCS 40 GPT 3rd DC 24 V 67G 41 42 R S T 52a 43 50 44 2 52b 51 46 47 3 4 Remote 52 Vp Vn 5 CT NA 45 1 6 DI1 48 60 61 62 53 63 RS485 (Scada) 64 13 ZCT DI2 54 14 59 When using ZCT (SGR) Control Power P N FG 65 KEYBOARD Vp Vn 66 67 RS485 (HIMIX) 68 Option HIMAP | Hyundai Intelligent Measuring & Protection Device | Connection Diagram HIMAP-SC R S T R1 PT 22 1 DISPLAY 2 3 Bus A 21 R2 23 4 5 24 6 R3 Programmable 25 Relay R S CPU T PT 27S 9 Bus B 26 R4 10 28 R5 R S 29 25A T PT Bus C 11 30 R6 31 12 32 R S R7 T 33 25B PT 34 13 Bus D Output 27 Local/ Remote CB On Local/ Remote CB Off 35 14 NA 36 37 CCS 38 Option 39 TCS 40 DC 24 V 41 42 43 50 52a 44 NA 45 52b 51 46 47 Remote 52 Vp Vn DI1 48 60 61 62 53 63 RS485 (Scada) 64 DI2 54 59 Control Power P N FG 65 KEYBOARD Vp Vn 66 67 RS485 (HIMIX) 68 Option ◀24 | 25▶ Terminal Block Pin Specification HIMAP-FI / M Type P N 60 61 62 63 64 65 66 67 68 41 42 43 44 45 46 47 48 50 51 52 53 54 55 56 57 58 59 21 22 1 2 23 24 3 4 25 26 5 6 27 28 7 8 29 30 9 10 31 32 11 12 33 34 13 14 35 36 15 16 37 38 17 18 39 40 19 20 Digital Output Control Power Terminal P N (+) (-) FG Communication Terminal 60 61 62 63 64 65 Vp Vn S.G Vp Vn HIMIX Communication Terminal 66 67 68 Vp Vn N.A 41 42 43 44 45 46 47 48 N.A Digital Input 50 51 52 53 54 55 56 57 58 59 52a 52b Remote D/I 1 D/I 2 N.A Common 21 23 25 27 29 31 33 35 37 39 R1 R2 R3 R4 R5 R6(CB On) R7(CB Off) N.A CCS TCS Analog Input 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 Ia Ib Ic Io Vab Vbc Vca Vo N.A N.A Terminal No. Description Application 50 51 52 53 54 21~22 23~24 25~26 27~28 29~30 31~32 33~34 35~36 37~38 39~40 CB On Status 52a CB Off Status 52b Remote Input General DI General DI R1 R2 R3 R4 R5 R6(CB On) R7(CB Off) N.A CCS TCS Fixed Fixed Fixed Variable Variable Programmable Relay Output Fixed Fixed N.A Fixed Fixed 2 4 6 8 10 12 14 16 18 20 HIMAP | Hyundai Intelligent Measuring & Protection Device | Characteristic Curve OCR & OCGR Inverse OP LEVEL 0.05~10.0 Very Inverse 0.01 OP LEVEL 0.05~10.0 0.01 MPR Extremely Inverse OP LEVEL 0.05~10.0 Current-Time Curve THR(49), 51LR, 50 Locked Rotor Cold Thermal Limit Hot Thermal Limit Stalled Rotor 0.01 ◀26 | 27▶ OVR OVGR Inverse Very Inverse OP LEVEL 0.05~10.0 OP LEVEL 0.05~10.0 0.01 0.01 DGR / SGR DGR SGR Operation Area Operation Area HIMAP | Hyundai Intelligent Measuring & Protection Device | Order Form HIMAP – ❶ – ❷ ❸ – ❹ (Option) Relay Type FI : Feeder / Incoming M : Motor 87M : Big(over than 3000 kW) Motor T : Transformer SC : Synchro Check Ground Fault Type C : OCGR D : DGR S : SGR Communication Function C : RS-485 X : N.A ※ TCS(Trip Coil Supervision) TCS Function T : Required X : N.A Circuit breaker coil supervision with option. ※ Specify followings separately - CT(Secondary) : 1 A - CB On/Off Switch N.A - 87M : Differential Type - Frequency : 50 Hz ※ Refer to the following specification for more detail relay function. Relay Function Table 1 (FI) Item C D S OCR ● ● ● OCGR ● MPR ● ● ● OCGR ● 87M ● ● ● MPR ● ● ● DGR SGR ● ● OVR ● ● ● UVR ● ● ● OVGR ● ● ● PSR ● ● ● Table 2 (M) Item C D S DGR SGR Ordering Example ● ● Table 3 (87M) Item C D S OCGR ● DGR SGR ● ● Remark ✽ 87M Self balancing( Differential( ) Table 4 (T) Item C D S DFR ● ● ● OCR P ● ● ● OCR S ● ● ● OCGR ● DGR SGR ● ● ) HIMAP-M-SC-X M : Motor Protection S : SGR(None grounding sys.) C : SCADA Communication X : TCS N.A HIMAP-FI-CC-T FI : Feeder Protection C : OCGR C : SCADA Communication T : TCS required ◀28 | 29▶ View & Dimension Weight 4.3 Kg HIMAP ↑ 156 ↑ 202.5 218.6 Front View 251.5 Top View 60 61 62 63 64 65 66 67 68 Side View 50 51 52 53 54 55 56 57 58 59 21 22 1 2 23 24 3 4 25 26 5 27 28 7 8 29 30 9 10 31 32 11 12 33 34 13 14 35 36 15 16 37 38 17 18 39 40 19 20 184.5 Rear View 186 Panel Cut-out Dimension 6 138 41 42 43 44 45 46 47 48 139 32.9 Hyundai Intelligent Communication & Measuring Device HICAM(Hyundai Intelligent Communication and Measuring Device) has integrated as many as 14 analog meters in one body. The measuring accuracy is below ±0.5% at rating. For power monitoring system connection, HICAM has RS485 communication port, communication control device (HICM series) and support modbus protocol. Remote CB On/Off control is possible by the command from power monitoring system. 1 Accuracy ±0.5% at rating 2 Voltage / Current Input CT: 0.1~30 A / PT: 10~380 V 3 Various Measuring 14 measuring points 4 Compact Size and Display - Various indicator and measuring display - Size: 202.5 (W) × 156 (H) × 186 (D) 5 Power Management System Connection - RS485 HD-Bus - Modbus protocol by communication control device (HICM Series) - Optic fiber communication (Option) HICAM | Hyundai Intelligent Communication & Measuring Device | Display Front View Communication Address Display Window Alarm Led Select Key Current Bar Graph Display Select Led Set Key D/I Status Led D/O Status Led I / O Point Point Item Input Remark AI Voltage 4 Default AI Current 4 Default 8 Default(41~50) DI Default(31~40) Output DO 5 37, 38(D04) : Remote CB On 39, 40(D05) : Remote CB Off 31~36(D01~D03) use current demand output. ◀32 | 33▶ Specification Specification Item Rating Accuracy Current 1 A or 5 A(0.1 A~30.0 A) Voltage 110 V or 190 V(10 V~380 V) Frequency 50 Hz or 60 Hz Measuring ±0.5 % Operation Guarantee -10 ℃ ~ 55 ℃ Restoration Guarantee -25 ℃ ~ 70 ℃ Circuit-Ground 100 ㏁ Between Circuits 100 ㏁ Between Contacts 100 ㏁ Power Frequency AC 60 Hz 2,000V/1 Min Lightning Impulse 1.2/50 ㎲ 5 kV Current Circuit Rating Current×3 : 3 hours / Rating Current×20 : 1 sec Voltage Circuit Rating Voltage×3 : 3 hours Control Power Rating Voltage×1.3 : 3 hours Temperature Insulation Resistance Voltage Withstand Overland Withstand Control Power AC 85 ~ 264 V (50 / 60 Hz), DC 90 ~ 120 V Communication Type RS–485 / Multi Drop Protocol HD-BUS / Modbus Standards KEMC1110, IEC1036 Size 202.5 (W)×156 (H)×186 (D) Weight 1.5 Kg Measuring Measuring Display Accuracy Remark Voltage 0~999999 V ±0.5% Line to Line Voltage Current 0~999999 A ±0.5% Phase Current Real Power 0~99999999 kW ±0.5% Reactive Power 0~99999999 kvar ±1.0% Apparent Power 0~99999999 kVA ±1.0% Accumulated Real Energy 0~99999999 kWh ±1.0% Accumulated Reactive Energy 0~99999999 kvarh ±1.0% Power Factor -1.0~1.0 PF ±0.5% Frequency 45~65 Hz ±0.01 Hz Reverse Real Power 0~999999 kW ±1.0% (-) Sign Reverse 0~999999 kWh ±1.0% (-) Sign HICAM | Hyundai Intelligent Communication & Measuring Device | Connection Diagram 3P 4W 3PT_3CT Remote CB On : 37, 38 Terminal Remote CB Off : 39, 40 Terminal 3P 3W 3PT_3CT Remote CB On : 37, 38 Terminal Remote CB Off : 39, 40 Terminal 3P 3W 2PT_2CT Remote CB On : 37, 38 Terminal Remote CB Off : 39, 40 Terminal 3P 3W 2PT_3CT Remote CB On : 37, 38 Terminal Remote CB Off : 39, 40 Terminal ◀34 | 35▶ View & Dimension Top View Right Side View Front View Panel Cut-out Dimension Rear View HHIS-WC-SE-B11-02, 2005.12 Designed by Design Korea www.hyundai-elec.com HEAD OFFICE 1 JEONHA-DONG, DONG-KU, ULSAN, KOREA TEL : 82-52-230-8101~8 FAX : 82-52-230-8100 SEOUL (Sales & Marketing) HYUNDAI B/D 140-2, GYE-DONG, JONGNO-GU, SEOUL, KOREA TEL : 82-2-746-7579, 7517 FAX : 82-2-746-7648 ORLANDO 3452 LAKE LYNDA DRIVE, SUITE 110, ORLANDO, FLORIDA 32817 U.S.A. TEL : 1-407-249-7350 FAX: 1-407-275-4940 LONDON 11TH FL., ST. MARTIN’S HOUSE, 1 HAMMERSMITH GROVE, LONDON W6 ONB, U.K. TEL : 44-208-600-7127 FAX: 44-208-741-5620, 4571 TOKYO 8TH FL., YURAKUCHO DENKI BLDG., 1-7-1, YURAKU-CHO, CHIYODA-GU, TOKYO, JAPAN 100-0006 TEL : 81-3-3212-2076, 3215-7159 FAX: 81-3-3211-2093 CAIRO APARTMENT NO.503, 5TH FL., BLDG., NO.7 BLOCK 2, 9TH DIVISION, EL-NASR ROAD, NEW MAADI, CAIRO, EGYPT TEL : 20-2-520-0148~9 FAX: 20-2-754-7528 SOFIA 1271, SOFIA 41, ROJEN BLVD. BULGARIA TEL : 359-2-938-1068 FAX: 359-2-936-0742 YANGZHONG LIANZHONG AVENUE, XINBA SCIENTIFIC AND TECHNOLOGIC ZONE, YANGZHONG CITY, JIANGSU PROVINCE, CHINA(212-212) (JIANGSU HYUNDAI NANZI ELECTRIC CO., LTD.) TEL : 86-511-842-0666, 0212 FAX: 86-511-842-0668, 0231