tick-tock measuring right in your hans tick
Transcription
tick-tock measuring right in your hans tick
CA740 Operation Manual NEW BENCHMARK OF MEASURING NEW BENCHMARK OF MEASURING PRECASTER Measuring Function Back-Light switch & Laser pointer switch a. Area Measurement Since1977 ‧To Enable and Disable back-light for HANS, press ‧Please press once for enabling Area measuring. ‧Laser will be activated when entering Area measuring ‧Follow the instructions on main screen to measure width and length. ‧Once you finish all instructions, Area is showed on screen. ‧To change display unit, press Next generation has arrived, Yet a new Benchmarking Standby Screen 1 2 Area Measuring Screen ‧To enable Laser Pointer, hold Also laser icon will also display continuously. TICK-TOCK MEASURING RIGHT IN YOUR HANS 3 Continously display for indicating Laser Pointer is activated 1x2=A Area Measuring Instructions b. Volume Measurement Error Code ‧Press twice to enter volume measuring. ‧Laser will be activated when entering Volume measuring. ‧Follow the instructions on main screen to measure width, length and height. Standby Screen ‧Once you finish all instructions, volume is showed on screen. ‧To change display unit, press 1 Code Description Solution Err01 Out of measuring range Measure in a proper range Err02 Reflected signal is too weak Select a better surface Err03 Out of display range (max value: 99999), Divide calculation into intermediate steps e.g: result of area or dimension is out Area Measuring Screen 2 Volume Measuring Screen 3 of display range. Err04 Pythagorean calculation error Check and verify values and steps are correct Err05 Low Battery Install a new battery Err06 Out of working temperature Measure in an environment within specified working temperature Err07 1x2x3=V Volume Measuring Instructions Ambient light is too strong Measure in a darker place (shadow target) Service Support Warranty Please contact your local dealer for further assistance, thank you. c. Indirect Measurement SX1O ‧Press to enter Indirect measuring. ‧All the calculation is based on Pythagorean theorem 2 2 2 (a +b =c ) to measure height indirectly. ‧Laser will be activated when entering Indirect c b measuring. Follow theinstructions on screen a to get slang range, horizon range then the height will be display on screen. 0.05m~40m PRECASTER Since1977 CA740 Laser Distance Meter PRECASTER ENTERPRISES CO., LTD. Operation Manual Read carefully before use Add:No.204, Sec. 2, Fu-Hsing Rd., Taichung, Taiwan Tel:886-4-2262 1000. FAX:886-4-2261 6565 http://www.precaster.com.tw First Press for Single Pythagoras e-mail:service@precaster.com.tw 5 Whole new engine, Faster, Better, no Doubt !! 6 P-HC-740 EM -1011 CA740 Operation Manual Cataloge ‧Before Start Using.........................................1 ‧Change of Battery ‧Overview for CA740.......................................2 ‧Overview for Screen ‧Specification ‧All Accessories ‧Turn on your HANS........................................3 ‧Measuring Distance ‧Add your measures ‧Subtract your measures ‧Dyna-Measuring (Continuous Measuring).........4 ‧Measuring reference ‧Unit of Measuring ‧Unit Switch Reference ‧Measuring Function.......................................5 ‧Volume Measurement ‧Indirect Measurement ‧Back-Light switch & Laser pointer switch..........6 ‧Error Code ‧Service Support Warranty Overview for CA740 A B H C I D M J K E F N 1 Dyna-Measuring (Continuous Measureing) ‧Before starting, please make sure battery is installed properly. For installing method, please read page 4. ‧Press once to activate HANS. ‧Initial screen will flash seconds for checking status. ‧After checking, standby screen will be displayed. ‧To activate Dyna Measuring (continuous measure) , hold then it will jump to Dyna Measuring mode. ‧When entering Dyna Measuring mode, laser beam will be also activated ‧To pause, please press or ‧Maximum and Minimum value will be displayed on screen ‧To quit Dyna Measuring and back to normal mode, press Standby Screen Measuring Distance 1 2 3 4 10 11 5 6 13 1. Laser Indicator 2. Indirect Measuring Single Pythagoras Summary of two Pythagoras Subtract of two Pythagoras 3. Measuring Function Area Measuring Volume Measuring 4. Measuring Reference 12 Specification Measure Range* 0.05M~40M 0.001M Accuracy* ±1.5mm Measure Speed* 0.5 sec. Laser Type 650 nm, Class 2, <1mW Beam Size 25mm@30M Battery 2 x AA Battery Battery Life Up to 10,000 measures Dimension 110mm X 45mm X 30mm Storage Temperature Dyna-Measuring Screen max. Laser Disactivated ‧If the laser is not activated, press to enable laser. ‧Then, move the laser dot of HANS onto your target and try to keep the dot on the target. ‧press to activate measure. ‧The whole measure will be finished until a beep is heard or measured result is appeared on the main screen. ‧Laser will be turnned off after measuring. 5. Add and Subtract 6. Maximum display 7. Minimum display 8. Stakes Direction Indicator 9. Main Screen and units 10. Countdown Measuring 11. Memories 12. Battery Status 13. Sub-Screen and units Measuring reference Finished Measuring Add your measures ‧calculating the summary of measures are simple only with few buttons. ‧Once you got your first measure, press ‧By default, reference is set at rear. ‧HANS has three reference: rear, front and pintail. ‧To change reference, press , each press will take effect. Changing sequence is front → rear → pintail. to save into memory (temporary saved) ‧Then find your next desired distance, once you find it, press again. ‧The summary will be displayed in main screen and you could see what you had added. Indicator for reference All Accessories Resolution Operation Temperature Standby Screen ‧CAUTION! Laser will be emitted upon when you turn HANS on. Check icon on the upper-left corner to check if laser is emitted. Overview for Screen Before Start Using ‧HANS is powered by 2 x AA Batteries ‧Battery status will be showed in initial screen. ‧In case if battery icon display continuously, it shows battery is about 1,000 measure times left. ‧Low power indicator will be twinkling when battery is low. ‧To change new batteries, remove back lid and observing correct polarity when install new batteries, then close back lid. J. Power Button / Clear K. Reference Switch / Laser pointer L. Receive Window M.Battery Cover N. Pin Tail NEW BENCHMARK OF MEASURING Turn on your HANS Laser Activated 9 Change of Battery A. LCD B. Add C. Measure / Dyna-Measure D.Measure Function Pythagoras Area Dimension E. Unit switch F. Strap Holder G.Laser Emitting Window H.Subtract I. Back-Light Operation Manual L G 7 8 ‧Thanks for choosing Precaster HANS (CA Series). Please read safety instruction carefully. ‧Laser radiation is emitted from this product. Use of controls, adjustment procedures other than those specified herein may result in laser radiation exposure. Never stare directly into beam or aim the laser beams at others. ‧HANS contains semiconductor laser diodes with wavelengths of 650 nanometers. ‧The total continuous output of the beams never exceeds 1.0 milli-watts. ‧HANS complies with EMC Test according to EN61000-6-3 : 2001+A11:2004, EN 61000-6-1:2001, EN 61000-4-2, EN 61000-4-3, EN 60825, FCC Test according to PART 15 CA740 NEW BENCHMARK OF MEASURING o o o ‧To change unit of measuring, press Subtract your measures b ‧Calculating the different of measures are simple only with few buttons. ‧Once you got your first measure, press d a -20 C~60 C 30 seconds -Device 180 seconds to save into memory (temporary saved) ‧Then find your desired distance, once you find it, press again. ‧The result will be displayed in main screen and you could see what you had subtract. Automatic switch-off -Laser . Unit will be switched by each hold. c o -5 C~40 C Unit of Measuring a. Carrying case b. CA740 c. Silica-gel Protector d. AA Batteries e. Safety Strap f. Engineering Pencil g. Operation manual e f NOTICE: Be sure to add and subtract in same unit g *The working range and accuracy depend on how well the energy of laser is reflected from surface (mostly comes from scattered light) and the target reflectivity. The brightness of laser point to ambient light intensity or use a target plate (Kodak White) may helps for increasing the working range and the stability of accuracy. *In favorable condition, accuracy could be in ±1.5 mm(2δ) and a deviation influence of ±0.25mm/m must be taken into count after ten meters. *In unfavorable condition, such as bright sunlight, rough surface, very short distance, or a poor and extra strong reflected signal may cause the deviation reach or over ±10mm and also may bring an ambiguous cycle which may lead the measures to an unexpected result.. 2 3 Unit Switch Reference meter feet inch 0'0" 1/32 inch Length m ft in 0'0" 1/32 in 尺 Area m 2 ft 2 ft 2 ft 2 ft 2 坪/尺 Volume m 3 ft 3 ft 3 ft 3 ft 3 m3 尺 2 4