D - PowerAndLight.Equipment

Transcription

D - PowerAndLight.Equipment
16-20 arapca.FH11 12/9/15 4:25 PM Page 4
C
M
Y
CM
MY
CY CMY
K
UK Partner for
Lighting Busbar System
25A - 40A
25A and 40A
Lighting Busbar System
GNL
ISO 9001-14001-18001
Composite
GNL - Lighting Busbar Trunking Systems
ISO 9001-14001-18001
Busbar trunking is a highly flexible and cost effective alternative to cables. The higher the current rating of the installation the more
cost effective busbar trunking becomes.
Typically, for an equivalent current rating, cable will weigh more than busbar trunking and occupy considerably more space.
Busbar trunking is far quicker to install than cable, especially when using the one bolt joint system offered by Gersan.
If we take into account the cost of the cable, the support structure needed to support it due to its greater weight, the cable pulling
required to get it in place, the cost of cable tray / ladder, cleats and terminations, the savings from using busbar can be
substantial.
Add to this the further cost saving afforded by the use of busbar with the aluminium conductors, an option offered by the Gersan
range, then the arguments in favour of using busbar systems instead of cable become overwhelming.
Busbar is also an environmentally better solution. The Gersan Super Compact range is R0HS compliant, manufactured from
halogen free materials, including all plastic parts and is fully recyclable.
Gersan busbar trunking is totally prefabricated in our ISO 9001:2008 factories meaning, no fabrication is required on site.
The ordered components simply need to be bolted together and tap-off boxes fitted.
As standard Gersan offer a two year warranty and guarantee spare parts to be available for ten years
All Gersan busbar systems comply with IEC/EN 61439 / 6, IEC/EN 60529
In relation to IEC/EN 61439 /6, Gersan busbar has the following type tests:
Temperature Rise Limits
Dielectric Properties
Short-Circuit Withstand Strength
Effectiveness of the Protective Circuit
Clearances and Creepage Distances
Mechanical Operation
Degree of Protection
Electrical Characteristics
Structural Strength
Insulation Resistance
Flame Propagation
Fire Barrier
Gersan Busbar Systems are protected by design patent.
2
16-20 arapca.FH11 12/9/15 4:25 PM Page 5
C
M
Y
CM
MY
CY CMY
K
GNL - Lighting Busbar Trunking Systems
ISO 9001-14001-18001
GNL 25-40A
IP55
GNL
* Lighting and low power busbar system
* Available in either 25A or 40A versions
* 3 or 5 pole system, the casing is not used as earth
* Fast and efficient single screw joint system
* Light weight aluminium housing
* Silver coated joint and tap-off connections
* Holds all international certifications and CE certification for busbar systems.
* Protected to IP55.
1
Composite
GNL - Lighting Busbar Trunking Systems
ISO 9001-14001-18001
GL - Technical Details
1000
690
50/60
55
Insulation Voltage
Operational Voltage
IFrequency
Degree of Protection
Rated Current
Short Circuit (1 Sec)
Short Circuit (Peak)
Resistance
Fault Resistance
Reactance
Impedance
Cross Section Phases
Cross Section Neutral
25
2.5
3,75
4.5
6,03
7,5
40
3,5
5,25
3
4,07
6,73
9,6
4
4
7,86
6
6
153,60
Cross Section Protective Conductor
The housing of the GNL range of busbar is manufactured from light weight aluminium. This design gives the housing high mechanical
strength making it particularly suitable for industrial applications. In addition, due to its high quality finish, the GNL range is particularly
suitable for installation in areas where aesthetics are important, such as retail.
The conductors are electrolytic copper 99.9% pure, tin plated and insulated along their full length (except at the tap-off points).
3 or 5 conductor versions are standard. Each 3 m standard straight length is provided with 3 tap-off points at 100 cm distance on one
side of the trunking.
End Feed and Centre Feed elements are available. The feed elements are IP55 as standard, and will accept supply cables up to ø16mm.
The contacts at the joints of the busbar and the contacts of all tap-off units are silver coated. The silver coating minimises the contact
impedances, thus preventing over-heating of the contacts in the event of overload.
The GNL range of busbar is fast and easy to assemble, as the joint is secured by tightening one screw.
2
21_35 arapca gl.FH11 12/9/15 4:25 PM Page 1
C
M
Y
CM
MY
CY CMY
K
GNL - Lighting Busbar Trunking Systems
ISO 9001-14001-18001
Standard Length Element P+N+PEc
Order code
Stock code
GNL 2533
GNL 4033
970400255513030
970500405513030
25
40
mm
Weight (Kg/unit)
3000
3000
0,820
0,920
mm
Weight (Kg/unit)
3000
3000
0,860
0,980
23
Busbar casing can be painted to customer requirements.
Please ask our design team for details.
45
Standard Length Element 3P+N+PEc
Order code
Stock code
GNL 2535
GNL 4035
970800255513050
970900405513050
25
40
23
45
3000
50
500
1000
1000
2
Composite
500
21_35 arapca gl.FH11 12/9/15 4:25 PM Page 2
C
M
Y
CM
MY
CY CMY
GNL - Lighting Busbar Trunking Systems
K
ISO 9001-14001-18001
End Feed unit (Left)
Order code
Stock code
GNL EF41
971000405510050
Weight (Kg/unit)
25-40
0,206
49
PG21
49
106
176
End Feed unit (Right)
Order code
Stock code
GNL EF42
971100405510050
Weight (Kg/unit)
25-40
0,269
49
PG21
40
106
50
226
3
Composite
21_35 arapca gl.FH11 12/9/15 4:25 PM Page 3
C
M
Y
CM
MY
CY CMY
K
GNL - Lighting Busbar Trunking Systems
ISO 9001-14001-18001
Center Feed Unit
Order code
Stock code
GNL EF43
971200405510050
Weight (Kg/unit)
25-40
1,880
PG 13.5
421
81
50
42,5
227
42,5
130
Flexible Elbow Joint
Order code
Stock code
GNL 40FX
972300405511000
Weight (Kg/unit)
0,800
25-40
49
106
49
176
L=1000 mm
40
50
226
4
Composite
106
21_35 arapca gl.FH11 12/9/15 4:25 PM Page 4
C
M
Y
CM
MY
CY CMY
K
GNL - Lighting Busbar Trunking Systems
ISO 9001-14001-18001
Lighting Fixture Tap-Off Plug - non-fused
Order code
Stock code
GNL 10 L1-CE
GNL 10 L2-CE
GNL 10 L3-CE
GNL 10 L4-1-CE
971500165521000
971600165521000
971700165521000
971800165521000
10
10
10
10
Phase
Weight (Kg/unit)
L1-N-CE
L2-N-CE
L3-N-CE
L1-L2-L3-N-CE
0,219
0,219
0,219
0,259
17
Standard cable length is 1000mm
Options for 2000mm and 3000mm cable length.
Please refer to our design team for further information.
End Cap
fl
Order code
Stock code
Weight (Kg/unit)
GNL EC40 (GNL EF41)
GNL EC41 (GNL EF42)
801300405550000
801300405550001
0,030
0,056
62
38
IP55 Joint Cover
Order code
Stock code
Weight (Kg/unit)
GNL ALC
80040040551AL40
0,144
5
Composite
21_35 arapca gl.FH11 12/9/15 4:25 PM Page 5
C
M
Y
CM
MY
CY CMY
K
GNL - Lighting Busbar Trunking Systems
ISO 9001-14001-18001
Lighting fixtures fixing hanger
Order code
Stock code
Weight (Kg/unit)
GNL SSU1
801400000040000
0,048
101
18
M5
9
32
Lighting fixtures fixing hanger
Order code
Stock code
Weight (Kg/unit)
GNL SSU2
801400000040002
0,005
22
50
30
10
15
Busbar fixing hanger
Order code
Stock code
Weight (Kg/unit)
GNL SSU3
801400000040003
0,105
20
57
20
55
9x20
85
9x20
6
Composite
ISO 9001-14001-18001
GNL - Lighting Busbar Trunking Systemss
Align and push the two lengths together.
Tighten the screw in the slot. It is not possible
to bring the two lengths together unless the
screw and slot are correctly aligned. This
ensures the conductors are connected
correctly.
Fit and secure the cover plates to the joint.
This provides mechanical strength to the
joint and rates the joint at IP55.
1500 -2000 mm
Suggested distance between hangers
The finished installation must be fully electrically tested.
Busbar trunking must only be installed by a qualified
experienced installer. The above information is an overview
of the installation procedure, not a detailed instruction and
therefore must not be used as an instruction manual.
2
DECLARATION OF COMFORMITY
according to TS EN ISO/IEC 17050-1
CE
MARKING
GERSAN ELEKTRiK TiC. VE SAN. A.S.
Anadolu Yakas1 OSB Gazi Bulvan No :39-41
Tuzla I ISTANBUL-TURKEY
Manufacturer's Name
Manufacturer's Address
declares that the product
Product Name
Model Number(s)
Features
Busbar Trunking System
GNL, GL, GGD, GS, GR
690V/1000V/36kV; 25A/6000A; 50/60 Hz ; Class F/H ; IP 43/55/65/68
conforms with the following standards;
Applied Standards:
Type Tests:
Safety
IEC/EN 61439-6
IEC/EN 62271
IEC/EN 60529
EMC
IEC/EN 61439-6 Annex K
Temperature Rise Limits
Electrical Characteristics
Dielectric Properties
Short-Circuit Strength
Effectiveness of The Protective Circuit
Clearance and Creepage Distances
Mechanical Operation
Degree of Protection
Structural Strength
Crushing Resistance
Resistance to Abnormal Heat
Resistance to Flame Propagation
Fire Barrier in Building Passing
EMC
Supplementary Information:
The product herewith complies with the requirements of the Low Voltage Directive and carries
the CE Marking accordingly.
This Declaration is granted on accounts of examinations made in;
ASTA Laboratory, the result of which are laid down in test report no. 16932
IPH-Berlin Laboratory, the result of which are laid down in test report no. 1624.2080603.709
VEIKl-VNL Laboratory, the result of which are laid down in test report no. 4552-76 VNL
LOVAG Laboratory, the result of which are laid down in test report no. 6994NNL
LVT Laboratory, the result of which are laid down in test report no. LVT.D.15-0439-R.OO
ISTANBUL 01.01.15
Power and Light Equipment Ltd are the sole UK partner for Gersan Elektrik
Gersan have experience spanning over 35 years manufacturing a wide range of electrical
equipment that includes busbar trunking, earthing systems, lightning protection, LV
distribution panels and pillars, cable containment systems and electric vehicle charging
systems.
Power and Light offer UK based technical and commercial support for all Gersan equipment.
Power and Light Equipment Ltd
Unit 15 Newark Business Park
3 Brunel Drive
Newark
Notts
NG24 2EG
Telephone - 0115 860 2301
Email - enquiries@powerandlight.equipment
Website - www.powerandlight.equipment
GNL - Lighting Busbar Trunking Systemss
ISO 9001-14001-18001