330 320 S 300e s 310 320 PS R 300 310
Transcription
330 320 S 300e s 310 320 PS R 300 310
s 23-B esrei r e ise s esrei r e ise sEdition s esrei r e ise s s esrei r e ise s non-reversing non-reversing reversing reversing TB GR 300 310 310 3 EC EC TB GR PS PS 300 s esrei r e ise s s esrei r e ise s i e ice c c3controls’ new line of Contactors are easy to install and designed to perform in a broad range of global applications. Our Series 300 Non-Reversing and Series 310 Reversing Contactors feature DIN rail and panel mounting, IP20 guarded terminals, multi-point coils, and include a wide variety of shared accessories. s esrei r e ise s TB TB s esrei r e ise s s esrei r e ise s miniature miniature miniature miniature 300 300 310 310 n enm em a a CONTACTORS s esrei r e ise s TB TB Series 300 Non-Reversing37 Series 310 Reversing39 Accessories41 Replacement Components43 Specifications44 Circuit Diagrams48 Electrical Life49 Dimensions50 PROVEN Conformity to Standards: UL 508, 60947-4-1A CSA C22.2 No. 14 IEC 60947-1, 60947-4-1 Certifications: UL File #: E236197 (Guide NLDX, NLDX7), E68568 (Guide NKCR, NKCR7) CE Marked (per EU Low Voltage Directive 2006/95/EC and RoHS Directive 2011/65/EU) Visit www.c3controls.com to download product certifications. NOTE: The scope (range, description, price, specifications, dimensions, etc.) of the product featured in this section is subject to change without notice. Refer to www.c3controls.com for product updates. s se s rei rei s es se s rei rei s es non-reversing non-reversing reversing reversing 300 300 310 310 320 320 330 330 CS CS 620 620 630 630 se s rei rei s es se s rei rei s es Contactors / se s rei rei s es se s rei rei s es se s rei rei s es CONTACTORS 300 300 310 310 se s rei rei s es se s rei rei s es miniature miniature miniature miniature c3controls offers a comprehensive line of Motor Control products designed and manufactured to meet the needs of the machine builder. We promise durable products at a price that gives you an edge, and we guarantee same-day shipping. Check out all the features of our Series 300/310 standard contactors below! DELIVERING SUPERIOR PRODUCT QUALITY AND MANUFACTURING EXCELLENCE Proven Our Series 300 and 310 Standard Contactors are UL Listed and CE marked, meeting global standards requirements. Compact Size Reduced panel area for lower installed costs—Four (4) frame sizes directly interchangeable with other manufacturers. Lower Cost Snap-on front mounted and side mounted auxiliary contacts install without the use of tools for lower installed costs. Convenient Wide variety of AC and DC operating coils for control circuit application flexibility. 50A to 105A DC operated devices feature electronic coil control. Easy to Install 35mm DIN rail mounting for all contactors from 9A to 105A for fast and easy installation and removal, or panel mounting for more secure installation in high shock and vibration applications. Modular Design Modular design allows easy installation of Series 320 Overload Relays and the complete range of Series 330 Motor Protection Circuit Breakers and accessories. Visible Certifications Our product certifications and electrical ratings are clearly marked on the outside of the device for easy reference during installation. Environmentally Friendly Environmentally friendly contacts are cadmium free and non-metallic materials are asbestos, halogen, and cadmium free. All c3controls products are compliant to the RoHS directives. Added Safety IP20 guarded terminals with dual terminal markings prevent accidental contact with live parts. Lifetime Warranty* Every product is backed by our lifetime warranty—unmatched in the industry—bringing you quality components that perform in the most demanding applications. Guaranteed Same-Day Shipping* Product availability reduces inventory, and improves cash-flow—saving you money. With c3controls any order for standard catalog items received by 6:00pm ET is guaranteed to ship same-day. Advantage Pricing Our approach to product development, manufacturing, and focus on servicing the OEM and Electrical Equipment Builder reduces cost. The result—the best value in the industry. *See c3controls Terms & Conditions “ When GinSan expanded to Canada, we needed to find a supplier that could provide us with motor protection products that conformed to Canadian standards without increasing our bottom line. During the evaluation and testing of a new supplier, c3controls motor control products met all of our quality standards. One added feature c3controls offers on their contactors is they have an extra, fourth contact—eliminating the need to add an extra auxiliary onto the device. Mike Fox, Engineering Chief · GinSan Industries Inc. 33 WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. ” se s rei rei s es se s rei rei s es se s rei rei s es i ei ce c non-reversing non-reversing reversing reversing se s rei rei s es se s rei rei s es se s rei rei s es miniature miniature miniature miniature /C TB GR 300 310 310 1 1 6 61 1 3 3 DS DS EC EC TB GR PS PS 300 se s rei rei s es se s rei rei s es se s rei rei s es se s rei rei s es se s rei rei s es se s rei rei s es ontactors Reversing Contactor ne nm em a a Contactors TB TB Non-Reversing Contactor 300 300 310 310 se s rei rei s es TB TB UNIQUE PRODUCT LINE FEATURES HIGH FAULT SCCR INTEGRAL AUXILIARY SEAMLESS COMPATIBILITY High fault short circuit current rating of 100kA @ 480V and 600V with Class J fuses, provides safety and reliability in high fault applications. Integral auxiliary contacts, 3 power poles + 1 auxiliary, are standard on all c3controls 9A to 25A non-reversing contactors. c3controls Series 310, 9A to 25A, AC/DC Reversing Contactors are compatible with directly mounted Series 320-B2 Overload Relays, and our 9A to 40A AC/DC Reversing Contactors direct mount onto Series 330 Motor Protection Circuit Breakers. COMMON ACCESSORIES MULTI-POINT TERMINAL COILS QUICK IDENTIFICATION Four terminal coils on all 9A to 105A AC and DC operated contactors are easily accessible, two on the line side and two on the load side. Enhanced markings, improved identification labels, and dual IEC and NEMA terminal markings ensure quick identification of product from all angles simplifying troubleshooting in panels with many devices. Designing starter assemblies and panels is easy! No more remembering which auxiliary works with each contactor. Our complete range of Series 300 Non-Reversing and Series 310 Reversing Contactors shares common accessories reducing inventory and simplifying installation and assembly. FIND IT FAST Contactors • • • • • Certifications Specifications Dimension Drawings Installation Instructions Easy to Buy www.c3controls.com WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. 34 se s rei rei s es se s rei rei s es non-reversing non-reversing reversing reversing se s rei rei s es se s rei rei s es miniature miniature miniature miniature 300 300 310 310 320 320 330 330 CS CS 620 620 630 630 se s rei rei s es se s rei rei s es Contactors / 300 300 310 310 se s rei rei s es se s rei rei s es se s rei rei s es Motor Control Device Solutions c3controls motor control devices are the perfect solution for manufacturers who want proper motor control and superior motor protection without having to overpay or compromise on quality. In fact, we engineer so much performance and flexibility into our products, we can deliver a remarkably better value than our competitors. c3controls products deliver like no other. Seamless Compatibility Contactors, overload relays and motor protection circuit breakers are designed by c3controls to work together, with common connections and accessories, resulting in a high functioning compact starter. LEADING THE INDUSTRY with our compact miniature 10HP contactors and control relays. One frame size (AC or DC)—28% reduction in panel area. Compact The small size of c3controls motor control devices, plus features like common accessories, enable assembly into smaller control panels for lower installed costs. Reliable Protection Contactors provide the repeated on/off switching for the motor and are designed for motor, actuator, solenoid, and other power switching applications. Overload relays provide Trip Class 10 protection against overload and phase-loss conditions, and have ambient temperature compensation for motor protection in high temperature environments. Ensures the protection of equipment and user. Motor protection circuit breakers provide overload, phase-loss and short circuit protection, can be used by themselves as manual motor controllers or with contactors in group motor installations, and can achieve Type 2 coordination for optimum performance. Type E self-protected combination manual motor controllers provide disconnecting means, branch circuit protection, motor control and motor overload protection all in a single device. Proven Our motor control devices are UL Listed and CE marked, meeting global standards requirements for use anywhere in the world. 35 WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. se s rei rei s es se s rei rei s es se s rei rei s es non-reversing non-reversing reversing reversing se s rei rei s es se s rei rei s es miniature miniature miniature miniature /C TB GR 300 310 310 1 1 6 61 1 3 3 DS DS EC EC TB GR PS PS 300 se s rei rei s es se s rei rei s es se s rei rei s es se s rei rei s es se s rei rei s es se s rei rei s es ontactors i ei ce c se s rei rei s es ne nm em a a Contactors NFPA 70 TB TB(NEC) National Electrical Code 300 300 310 310 Understanding what functions are needed in your motor control circuit se s rei rei s es is critical when selecting motor control devices. Engineers benefit from the standards and codes established to ensure safety and protection to personnel and equipment. TB TB More than just knowing the standards, c3controls, as a manufacturer of motor control products, has the application expertise you need to select the right products. c3controls & Article 430 - Motors, Motor Circuits and Controllers To Supply Motor disconnecting means NEC Part c3controls Product Series Part IX 330 Motor branchcircuit, short circuit, and ground-fault protection Part IV Motor circuit conductor Part II Motor controller Part VII Type E: 330 630 Type E: 330 630 Motor control circuits Part VI Motor overload protection Part III Motor 630 300/310 330 620 630 Type E: 330 630 320 330 620 630 Type E: 330 630 Our motor control products align with Article 430 Part VII, Motor Controller, of the NFPA 70, the National Electrical Code. Part I WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. 36 series series 300 310 320 330 CS 620 630 series N o n -R e v e r s i n g / non-reversing reversing series series IT’S 300 310 EASY TO series BUILD series YOUR series OWN series CONTACTOR Simply pick the code number from each of the sections below and combine tominiature build your part number. them miniature Non-Reversing Contactors I IIIII Example: To build one of our most popular Contactors, the part number would be I + II + III o r 3 0 0 - S 09N30D 10 I. NON-REVERSING CONTACTORS (3 NORMALLY OPEN POLES) RATINGS FOR SWITCHING AC MOTORS - AC-2, AC-3 kW (50Hz) HP (60Hz) MAX. le (A) 3 PHASE 1 PHASE 3 PHASE CODE AC-3 AC-1 230V 400/415V 500V690V 115V230V 200V230V 460V575V PRICE 300-S09N30 9 25 2.2 4 5.5 5.5 1/2 1-1/2 3 3 5 7-1/2 $ 53.00 300-S12N30 12 25 3 5.5 7.5 7.5 3/4 2 3 3 7-1/2 10 $ 79.00 300-S18N30 1832 4 7.5 1010 1 3 5 5 1015 $ 87.00 300-S25N30 25457.5 11 1515 2 37-1/2 7-1/21515 $ 99.00 300-S32N30 3260 9 1518.5 18.5 3 5 1010 2025 $130.00 300-S40N30 4060 1118.52530 3 5 1015 3025 $178.00 300-S50N30 5090 15 22 3035 37-1/21515 4040 $212.00 300-S65N30 6511018.530 4045 510 2020 5050 $236.00 300-S80N30 8011022 37 45457-1/2 15 2025 5060 $271.00 300-S95N30 9514025 45 55557-1/2 15 2530 6075 $346.00 300-S105N30105 140305565651020 30407575 $398.00 II. COIL VOLTAGE CODE AC COIL VOLTAGE CODES VOLTAGE 12 24 48 110120 208220230240277380400400 ~ 415440480500 550600 50Hz G H K D——M———QAM R S—T U— 60Hz B C J—D L——F P—— — —R——T 50/60Hz XB XCXJXDXAD—XAJXNXF—— XAM — XQ—— —— DC COIL VOLTAGE CODES PRICE VOLTAGE 12 24 24 ~ 28 48 42 ~ 50 110 125 110 ~ 130 208 ~ 240 250 -S09 to -S25 ZB ZC — ZK — ZD ZQ — — ZP $ 35.00 -S32 to -S40 ZB ZC — ZK — ZD ZQ — — ZP $ 78.00 -S50 to -S105 — — EC — EK — — EL EE — $282.00 III. AUXILIARY CONTACT CONFIGURATION CODEDESCRIPTION 00 Without Auxiliary Contacts (Contactors 300-S32 to 300-S105 only) 10 1 Normally Open* 01 1 Normally Closed* PRICE — $ 18.00 $ 18.00 DISC OUNT SC HEDULE *NOTE: Integral right side mounted on 9A ~ 25A contactors, front mounted on 32A ~ 105A contactors. Some of Our Popular Configurations: NON-REVERSING CONTACTORS CATALOG NUMBER 300-S09N30D10 300-S09N30ZC10 300-S25N30D10 37 DESCRIPTION Non-Reversing, 9A, 3 Pole, 120V AC Coil, 1 NO Auxiliary Contact Non-Reversing, 9A, 3 Pole, 24V DC Coil, 1 NO Auxiliary Contact Non-Reversing, 25A, 3 Pole, 120V AC Coil, 1 NO Auxiliary Contact PRICE $ 71.00 $106.00 $117.00 WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. F series series series / N -R 22 16 13 DS EC TB GR PS 300 series series series series series on iec 22 nema Non-Reversing Contactors c3controls Series 300 Contactors are ideal for motor, actuator, solenoid, and other power switching applications where panel space is at a premium and device modularity is required to satisfy virtually any application requirement. cULus and CE Markings make them suitable for use anywhere in the world. Small size, IP20 guarded terminals with dual terminal markings, and shared accessories will help reduce your total installed costs and enhance the features and performance of your equipment. Just look and see what the Series 300 has to offer. eversing iec non-reversing series series TB nema series TB Contactors series series 300 miniature Product features include: • NEW – High fault short circuit rating of 100kA @ 480V and 600V with Class J fuses, provides safety and reliability in high fault applications. • NEW – Series 300 25A contactor has an integral auxiliary, 3 power poles plus 1 auxiliary, provides more functionality in a smaller package, reducing bill of material and panel size. • IMPROVED – Removable and replaceable identification marker, standard on all c3controls contactors and Series 300-SFA Auxiliaries, for labeling contactors and front mounted auxiliary contacts - simplifies trouble shooting in panels with many contactors. • IMPROVED – Our side mounted auxiliaries and interlocks are now 9mm wide and install without the use of tools onto Series 300 Contactors, reducing panel footprint and simplying installation. • IMPROVED – Multi-point terminal coils on 9A to 80A AC and DC contactors providing wiring flexibility and installation convenience. • IMPROVED – Lower power consumption for 32A and 40A DC contactors. • IMPROVED – Enhanced markings and high visibility labels for ease of troubleshooting and maintenance. • Compact size – four (4) frame sizes for devices rated from 9A to 105A. Contactors rated 15HP @ 460V (11kW @ 400V) are only 45mm (1-49/64”) wide reducing panel area requirements – smaller enclosures can be used for lower installed costs. • AC and DC operating coils for control circuit application flexibility. 32A to 105A DC operated devices feature electronic coil control. • Environmentally friendly contacts are cadmium free and non-metallic materials are asbestos, halogen, and cadmium free. • IP20 guarded terminals prevent accidental contact with live parts. • Dual IEC and NEMA terminal markings for ease of wiring anywhere in the world. • 35mm DIN rail mounting for all contactors from 9A to 105A for fast and easy installation and removal or panel mounting for more secure installation in high shock and vibration applications. Our 9A to 25A devices are easily installed or removed without the use of tools. • Modular design allows easy installation of Series 320 Overload Relays and the complete range of Series 330 Motor Protection Circuit Breakers and accessories. • Combination head terminal screws allow the use of straight, phillips, or posidrive screwdrivers. Allen head screws on 50A through 105A contactors make it easy to apply the proper terminal tightening torque for secure conductor connections. • Snap-on front mounted auxiliary contacts install without the use of tools for lower installed costs. Single circuits available so you only purchase what you need. U N I Q U E P ROD UC T FEATU R ES IMPROVED - Multi-Point Terminal Coils Four terminal coils on all 9A to 105A AC and DC operated contactors are easily accessible on contactor and overload relay assemblies or contactor and motor protection circuit breaker assemblies. The control circuit can be wired from the line side or the load side of the contactor, whichever is most convenient for the installation. Control circuit wire runs can be minimized, and the devices can be easily substituted in your existing equipment without disturbing or changing your control wires. So no matter what components are being used, Series 300 Contactors can be easily and quickly wired, reducing your labor and installation costs. WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. 38 series 310 320 330 CS 620 630 series series Reversing / series series series reversing I T ’ S E A S Y T O B U I LD YOUR OWN C ONTA C TOR series 310 Simply pick the code number from each of the sections below and combine them to build your part number. miniature Reversing Contactors I II III IV Example: To build one of our most popular Contactors, the part number would be I + II + III + IV o r 310-S 25N30D 22 I. REVERSING CONTACTORS (3 NORMALLY OPEN POLES) RATINGS FOR SWITCHING AC MOTORS - AC-2, AC-3 kW (50Hz) HP (60Hz) MAX. le (A) 3 PHASE 1 PHASE 3 PHASE CODE AC-3AC-1230V 400/415V 500V690V115V230V200V230V460V575VPRICE 310-S09N30 925 2.245.5 5.5 1/2 1-1/2 335 7-1/2 $214.00 310-S12N30 12 2535.57.5 7.5 3/4233 7-1/2 10 $266.00 310-S18N30 18 3247.51010135510 15 $282.00 310-S25N30 25457.511 15 15 2 37-1/2 7-1/21515 $342.00 310-S32N30 326091518.5 18.53 510102025 $415.00 310-S40N30 40601118.525303 5 10153025 $511.00 310-S50N30 50901522 303537-1/2 15154040 $625.00 310-S65N30 65110 18.530 40455 1020205050 $673.00 310-S80N30 801102237 4545 7-1/2 1520255060 $743.00 II. COIL VOLTAGE CODE AC COIL VOLTAGE CODES 12 24 48 110120208220230240277380400400 ~ 415440480500 550600 G H K D ——M——— QAM R S — T U— B C J—D L——F P—— — —R——T XB XCXJXDXAD—XAJXNXF—— XAM — XQ—— —— DC COIL VOLTAGE CODES PRICE VOLTAGE 12 24 24 ~ 28 48 42 ~ 50 110 125 110 ~ 130 208 ~ 240 250 -S09 to -S25 ZB ZC — ZK — ZD ZQ — — ZP $ 70.00 -S32 to -S40 ZB ZC — ZK — ZD ZQ — — ZP $157.00 -S50 to -S80 — — EC — EK — — EL EE — $563.00 VOLTAGE 50Hz 60Hz 50/60Hz III. AUXILIARY CONTACT CONFIGURATION CODEDESCRIPTION PRICE 00 Without Auxiliary Contacts — (Contactors 310-S32 to 310-S80 only) 22 2 Normally Open (1 NO on Forward Contactor1$ 47.00 and 1 NO on Reverse Contactor1) and 2 Normally Closed (1 NC on Forward Contactor2 and 1 NC on Reverse Contactor2) IV. OPTIONS CODE DESCRIPTION (Blank) With Power Wires WW Without Interconnecting Power Wires FOR CONTACTOR — -S09 to -S25 -S32 to -S40 -S50 to -S80 -PRICE (deduct) — – $ 34.00 – $ 51.00 – $ 97.00 1 Integral right side mounted on 9A ~ 25A contactors, front mounted on 32A ~ 80A contactors. 2Integrated contacts as part of the electrical/mechanical interlock. 39 DISC OUNT SC HEDULE WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. F series series series 16 13 DS EC TB GR PS/ R 300 310 series series series series series series eversing iec reversing series series miniature miniature Reversing Contactors c3controls new Series 310 Reversing Contactors are ideal for reversing in applications s e r i e motors s where panel space is at a premium and device modularity is required to satisfy virtually any application requirement. cULus and CE Markings make them suitable for use anywhere in the world. A common mechanical interlock, power wiring modules, n e mIP20 a guarded terminals with dual terminal markings, and shared accessories help reduce your total installed costs and enhance the features and performance of your equipment. Just look and see what our new Series 310 has to offer. TB Contactors non-reversing 300 310 series TB Product features include: • NEW – High fault short circuit rating of 100kA @ 480V and 600V with Class J fuses, provides safety and reliability in high fault applications. • NEW – Series 300 25A contactor has an integral – auxiliary, 3 power poles plus 1 auxiliary, provides more functionality in a smaller package, reducing bill of material and panel size. • IMPROVED – Modular design allows Series 320-B2 Overload Relays to be directly mounted onto Series 310, 9A to 25A, reversing contactors resulting in a high functioning compact starter. • IMPROVED – Removable and replaceable identification marker, standard on all c3controls contactors, simplifies troubleshooting in panels with many devices. • IMPROVED – Multi-point terminal coils on 9A to 80A AC and DC contactors providing wiring flexibility and installation convenience. • IMPROVED – Lower power consumption for 32A and 40A DC contactors. • IMPROVED – Series 330 Motor Protection Circuit Breakers direct mount onto Series 310, 9A to 40A AC and DC, reversing contactors, resulting in a high functioning compact starter. • Modular design allows use with separately mounted overload relays, or Series 320 Overload Relays can be directly mounted on Series 310 32A to 50A reversing contactors without load-side interconnecting power wires. • AC and DC operating coils for control circuit application flexibility. 50A to 80A DC operated devices feature electronic coil control. • Environmentally friendly contacts are cadmium free and non-metallic materials are asbestos, halogen and cadmium free. • IP20 guarded terminals prevent accidental contact with live parts. • Dual IEC and NEMA terminal markings for ease of wiring anywhere in the world. • Device identification marker for labeling contactors and front mounted auxiliary contacts simplify trouble shooting in panels without the use of tools. • Power wiring modules provide reliable, rigid interconnections between the forward and reverse contactors. • Combination head terminal screws allow the use of straight, phillips, or posidrive screwdrivers. Allen head screws on 50A through 80A contactors make it easy to apply the proper terminal tightening torque for secure conductor connections. • Snap-on front mounted auxiliary contacts install without the use of tools for lower installed costs. Single circuits available so you only purchase what you need. UNIQUE PRODUCT FEATURES Series 310 Reversing Contactors feature a single, side mounted electrical and mechanical or mechanical only interlock that is used for the whole range of contactors, enabling a 9A contactor to be interlocked with a 105A contactor. The side mounted interlock doesn’t increase the depth of the contactor and doesn’t prevent front mounted auxiliary contacts from being added to either the forward or reverse contactors. Contactors are physically secured together with a dovetail bracket that installs from the bottom of the contactor – so it can’t fall out when it is installed on a DIN rail or on a panel, even in high vibration applications. To complete the reversing contactor assembly, attractive, insulated wiring modules provide error free interconnections between the forward and reverse contactors. Simple to use, modular accessories make reversing contactors easy to assemble in the field – or order them factory assembled. Either way you’ll get the performance and features you need for your reversing motor applications. Some of Our Popular Configurations: REVERSING CONTACTORS CATALOG NUMBER 310-S09N30D22 310-S09N30ZC22 310-S25N30D22 310-S25N30ZC22 310-S32N30D22 DESCRIPTION Reversing, 9A, 3 Pole, 120V AC Coil, 2 NO and 2 NC Auxiliary Contacts Reversing, 9A, 3 Pole, 24V DC Coil, 2 NO and 2 NC Auxiliary Contacts Reversing, 25A, 3 Pole, 120V AC Coil, 2 NO and 2 NC Auxiliary Contacts Reversing, 25A, 3 Pole, 24V DC Coil, 2 NO and 2 NC Auxiliary Contacts Reversing, 32A, 3 Pole, 120V AC Coil, 2 NO and 2 NC Auxiliary Contacts WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. PRICE $261.00 $331.00 $389.00 $459.00 $462.00 40 se s rei rei s es se s rei rei s es non-reversing non-reversing reversing reversing 300 300 310 310 320 320 330 330 CS CS 620 620 630 630 SIDE MOUNTED AUXILIARY CONTACTS Our front mounted auxiliary contacts feature IP20 guarded terminals to protect against accidental contact with live parts. The device identification marker simplifies trouble shooting in panels with many contactors. These contacts snap-on and install without the use of tools. NOTE: See chart below for maximum number of front mounted auxiliary contacts. Side mounted auxiliary contacts feature IP20 guarded terminals to protect against accidental contact with live parts. NOTE: See chart at left for maximum number of side mounted auxiliary contacts. miniature miniature CONTACT CONNECTION CONFIGURATIONDIAGRAMPRICE $11.50 -4 14 14 300-SSA02 62 NO NO 2 Normally Open* 300-SSA02X NO 2 Normally Closed* NO 51 61 84 63 83 64 73 62 $31.00 $31.00 $31.00 71 82 81 52 72 53 74 41 $31.00 *NOTE: For use with 300-SSA11 or 300-SSA20 when more than one side mounted auxiliary contact module is installed on the same side of the contactor. INTERLOCKS Reversing contactor power wiring modules make field assembly of reversing contactors easy. Line and load side over-molded copper bus bar conductors ensure error free installation and make for a rigid assembly with a mechanical interlock (300-SMI) or electrial/ mechanical interlock (300-SMEI). F 54 61 300-SSA20X WIRING MODULES DI S C O U N T SC H E D U L E 53 54 MAXIMUM NUMBER 4 6 8 FOR USE WITH CONTACTORS S09, S12, S18, S25 S32, S40 S50, S65, S80 1 Normally Open and 1 Normally Closed* 83 300-SSA11X 71 MAXIMUM NUMBER OF FRONT OR SIDE MOUNTED AUXILIARY CONTACTS CODE 300-RWS25 300-RWS40 300-RWS80 22 NO NC 84 $17.00 -6 CONTACTOR S09, S12, S18, S25 S32, S40 S50, S65, S80, S95, S105 21 72 1 Normally Closed Delayed Break 11 12 -5 NC $31.00 $17.00 -8 300-SFA01DB 2 Normally Closed 41 -7 NO 24 NO NO 31 1 Normally Open Early Make 22 $31.00 $11.50 -2 300-SFA10EM 21 42 1 Normally Closed 300-SSA20 NO 2 Normally Open NO 13 23 NO NC 13 32 300-SFA01 -1 NC 1 Normally Open and 1 Normally Closed 43 1 Normally Open 300-SSA11 33 300-SFA10 -3 NO CONTACT CONNECTION CONFIGURATIONDIAGRAM PRICE 44 CODE CODE 34 miniature miniature se s rei rei s es 43 300 300 310 310 se s rei rei s es 31 FRONT MOUNTED AUXILIARY CONTACTS se s rei rei s es se s rei rei s es se s rei rei s es 44 se s rei rei s es 32 se s rei rei s es A cc e s s o r i e s / PRICE $40.00 $51.00 $97.00 MECHANICAL INTERLOCK Our side mounted mechanical interlock for use with reversing contactors, reversing starters, two-speed starters and star-delta (wye-delta) starters. This single interlock can be used with all size contactors from 9A ~ 105A, preventing the forward and reverse contactors from being energized at the same time. ELECTRICAL & MECHANICAL INTERLOCK c3controls now offers an electrical/mechanical interlock for reversing contactors. This interlock has the same features as the mechanical interlock but also has two normally closed auxiliaries built into the unit for electrical interlocking, eliminating the need for two normally closed auxiliary contacts and the mechanical interlock. The result of integrating the normally closed auxiliary contact is decreased width of reversing contactors and more available auxiliary contact locations. CODEDESCRIPTION PRICE 300-SMI 300-SMEI $34.00 $43.00 Side Mounted Mechanical Interlock Side Mounted Electrical/Mechanical Interlock WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. se s rei rei s es se s rei rei s es se s rei rei s es non-reversing non-reversing reversing reversing se s rei rei s es se s rei rei s es /A TB GR 300 310 310 1 1 6 61 1 3 3 DS DS EC EC TB GR PS PS 300 se s rei rei s es se s rei rei s es se s rei rei s es se s rei rei s es se s rei rei s es se s rei rei s es cc e s s o r i e s i ei ce c TB TB Contactors A cc e ss o r i e s f o r N o n - Rseesvrei reeisre ss i n g and Reversing Contactors 300 300 310 310 The complete range of Series 300 Non-Reversing Contactors andnSeries Reversing Contactors share common accessoriesminiature including single e nm e 310 m a a miniature miniature miniature circuit front mounted auxiliary contacts, two circuit side mounted auxiliary contacts, a single electrical/mechanical or mechanical interlock, and coil mounted surge suppressors. Designing starter assemblies and panels is easy – you don’t have to remember which auxiliary is required for each contactor, they all work together. Installation is easy too – once you learn how to install each accessory, it’s always the same no matter se sisn’t rei reenough is e s – you’ll also reduce your inventory and maximize its flexibility, what contactor it’s being installed on. If simple design and assembly because unique accessories are not required for each size contactor. TB TB SURGE SUPPRESSORS Coil mounted surge suppressors protect sensitive electronic components in control circuits from damaging line voltage spikes. DISC OUNT SC HEDULE F RC SURGE SUPPRESSOR CODE VOLTAGE RANGE 300-SRCS2J 24 ~ 48V AC 300-SRCS2AH 50 ~ 127V AC 300-SRCS2M 130 ~ 250V AC 300-SRCS5J 24 ~ 48V AC 300-SRCS5AH 50 ~ 127V AC 300-SRCS5M 130 ~ 250V AC A1 A2 DIODE SURGE SUPPRESSOR CODE VOLTAGE RANGE 300-SDS5T 12 ~ 600V DCA1 FOR USE WITH CONTACTOR S09, S12, S18, S25, S32, S40 S09, S12, S18, S25, S32, S40 S09, S12, S18, S25, S32, S40 S50, S65, S80, S95, S105 S50, S65, S80, S95, S105 S50, S65, S80, S95, S105 PRICE $29.00 FOR USE WITH CONTACTOR S09, S12, S18, S25, S32, S40, S50, S65, S80, S95, S105 PRICE $29.00 $29.00 $29.00 $29.00 $29.00 $29.00 A2 WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. 42 se s rei rei s es se s rei rei s es non-reversing non-reversing reversing reversing 300 300 310 310 320 320 330 330 CS CS 620 620 630 630 se s rei rei s es IT’S se s rei rei s es se s rei rei s es se s rei rei s es Replacement Components / EASY se s rei rei s es 300 300 310 310 TO BUILD YOUR se s rei rei s es OWN se s rei rei s es OPERATING COIL Simply pick the code number from each of the sections below and combine part number. themminiature to build your miniature miniature miniature Operating Coils I II Example: To build one of our most popular Operating Coils, the part number would be I + II o r A CS 2 5 D I. OPERATING COIL TYPE CODE ACS25 ACS40 ACS105 DCS25 DCS40 DCS105 DESCRIPTION AC Operating Coil AC Operating Coil AC Operating Coil DC Operating Coil DC Operating Coil DC Operating Coil FOR USE WITH CONTACTORS S09, S12, S18, S25 S32, S40 S50, S65, S80, S95, S105 S09, S12, S18, S25 S32, S40 S50, S65, S80, S95, S105 PRICE $ 26.00 $ 30.00 $ 42.00 $ 53.00 $141.00 $211.00 II. COIL COIL VOLTAGE VOLTAGE CODE CODE II. AC COIL COIL VOLTAGE VOLTAGE CODES CODES AC 12 24 24 48 48 110 110120208220230240277380400 440480500550 550600 VOLTAGE 12 120208220230240277380400400 ~ 415440480500 600 G H H K K D D ——M———QAM ——M——— QAM R S — T T U U— 50Hz G — 60Hz B B C C J J—D L— —F P—— — — — —R——T 60Hz — D L —— F P—— R— — T 50/60Hz XB XBXCXJXD XCXJXDXAD XAD— —XAJ XNXF—— XAM — — XQ—— XQ——— —— 50/60Hz XAJXNXF ——XAM — DC COIL COIL VOLTAGE VOLTAGE CODES CODES DC 12 24 24~~28 28 48 42 ~~ 50 50 110 125 110 ~ 130 208 ~~ 240 240 250 VOLTAGE 12 24 24 42 125 130 208 250 ZB ZK — ZQ — ZP -S09 to -S25 ZB ZC — — ZD ZQ — — ZP -S40 ZB ZC — ZK — ZD ZQ — — ZP -S32 to -S40 — — EC—EK— — EL EE — -S105 — — EC — EK — — EL EE -S50 to -S105 — — EC—EK— — EL EE — CONTACT KITS One contact kit includes six stationary contacts, three moving contacts and miscellaneous parts. FOR USE WITH CODE CONTACTORSPRICE 300-SCK09 S09 $ 31.00 300-SCK12 S12 $ 44.00 300-SCK18 S18 $ 45.00 300-SCK25 S25 $ 62.00 300-SCK32 S32 $ 74.00 300-SCK40S40 $122.00 300-SCK50S50 $151.00 300-SCK65S65 $176.00 300-SCK80S80 $211.00 300-SCK95S95 $229.00 300-SCK105S105 $281.00 DISC OU NT SC HEDULE 43 WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. F se s rei rei s es se s rei rei s es se s rei rei s es i ei ce c non-reversing non-reversing reversing reversing se s rei rei s es se s rei rei s es se s rei rei s es /S TB GR 300 310 310 1 1 6 61 1 3 3 DS DS EC EC TB GR PS PS 300 se s rei rei s es se s rei rei s es se s rei rei s es se s rei rei s es se s rei rei s es se s rei rei s es pecifications TB TB ELECTRICAL SPECIFICATIONS Contactors Specifications: 300 300 310 310 S09 S12S18S25S32S40S50 S65S80S95S105 ne nm em a a miniature miniature miniature miniature ELECTRICAL GENERAL UNITS Rated Operating Frequency Hz 25 ~ 400 Impedance per Pole mΩ 1.90 1.901.601.602.101.60 0.850.86 0.860.76 0.76 se s rei rei s es POWER DISSIPATION PER POLE AC-1 W 1.47 1.472.463.344.603.426.8910.4010.4014.8914.89 AC-3 W 0.19 0.340.781.031.311.522.12 3.635.506.86 8.37 Rated Coil FrequenciesAC: 50Hz, 60Hz, 50/60Hz and DC ELECTRICAL UL/CSA APPLICATIONS Rated Operating Voltage, Ue VAC 600 General Purpose Current Rating A 25 25 32 32 60 60 90 110 110 140 140 RATED 1 PHASE OPERATING CURRENT, Ie 115V A 9.813.81624 3434345680 80100 230V A 10 121728 2828404050 6088 RATED 1 PHASE OPERATING POWER, Pe 115V HP1/23/4 1 2 3 3 3 57-1/2 7-1/210 230V HP 1-1/22 33 55 7-1/2 10151520 RATED 3 PHASE OPERATING CURRENT, Ie 200V A 11 11 17.525.3 32.232.248.362.162.1 78.2 92 230V A 9.69.615.222 2842425468 80104 460V A 7.6111421 2740526565 7796 575V A 9 111717 2727415262 7777 RATED 3 PHASE OPERATING POWER, Pe 200V HP 3 3 57-1/21010152020 2530 230V HP 3 3 57-1/21015152025 3040 460V HP 57-1/21015 2030 40 50 50 6075 575V HP 7-1/2101515 2525405060 7575 Size 00—0—1—2——3— Standard Short Circuit Current kA 5 5 5 5 5 5 10 10 10 10 10 Maximum Fuse Size A 30 30 60 60 60 60 100 125 150 175 200 High Fault Short Circuit Current kA 100 100 100 100 100 100 100 100 100 100 100 Maximum Fuse Size (Class J) A 25 25 40 40 50 60 90 100 125 150 175 Electrical Endurance, AC-3 at Maximum Rated 3 Phase Ops. 1.8 2.0 1.6 1.6 1.5 1.5 1.6 1.8 1.5 1.5 1.0 Operating Power (@460V) (mill.) ELECTRICAL IEC APPLICATIONS Rated Insulation Voltage, Ui V 1000 Rated Impulse Voltage Withstand, Uimp kV 6 6 6 6 6 6 8 8 8 8 8 Rated Operating Voltage, Ue VAC 690 Rated Thermal Current, Ith for Ambient Temperature A 25253245606090110 110 140140 < 55° C (131° F) RATED AC-1 OPERATING CURRENT, le At 55° C (131° F) A 25 25 32 45 60 60 90 110 110 140 140 At 70° C (158° F) A 20 20 25 32 48 48 72 88 88 110 110 RATED AC-3 OPERATING CURRENT, le 220 ~ 240V A 9 12 1825 3240 5065 80 95 105 380 ~ 400V A 9 12 1825 3240 5065 80 95 105 415 ~ 440V A 9 12 1825 3240 5065 80 95 105 500V A 7.510.51419 2432 3855 63 79 85 660 ~ 690V A 7 9 1315 2225 3444 48 60 80 RATED 3 PHASE AC-3 OPERATING POWER, Pe 220 ~ 240V kW 2.2 3 4 6.5 9 11 15 18.5 22 25 30 380 ~ 400V kW 4 5.5 7.5 11 15 18.5 22 30 37 45 55 415 ~ 440V kW 4 5.5 9 12.5 15 22 30 37 45 55 55 500V kW5.57.5 101518.525 3040 45 55 65 660 ~ 690V kW 5.5 7.5 10 15 18.5 30 33 45 45 55 65 TB TB WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. 44 se s rei rei s es se s rei rei s es non-reversing non-reversing reversing reversing 300 300 310 310 320 320 330 330 CS CS 620 620 630 630 se s rei rei s es se s rei rei s es Specifications / se s rei rei s es se s rei rei s es se s rei rei s es ELECTRICAL AND COIL CHARACTERISTICS SPECIFICATIONS S09 S12S18S25S32S40S50 S65S80S95S105 se s rei rei s es se sIEC rei APPLICATIONS rei s es ELECTRICAL (CONTINUED) UNITS RATED AC-4 OPERATING CURRENT, le miniature miniature (Achieves miniature miniature maximum of 200,000 operations) 220 ~ 240V A 7.5 10.0 15.020.8 26.733.3 41.754.2 66.7 79.2 87.5 380 ~ 400V A 7.5 10.0 15.020.8 26.733.3 41.754.2 66.7 79.2 87.5 415 ~ 440V A 7.5 10.0 15.020.8 26.733.3 41.754.2 66.7 79.2 87.5 500V A 6.3 8.8 11.715.8 20.026.7 31.745.8 52.5 65.8 70.8 660 ~ 690V A 5.8 7.6 10.812.5 18.320.8 28.336.7 40.0 50.0 66.7 RATED AC-4 OPERATING POWER, Pe (Achieves maximum of 200,000 operations) 220 ~ 240V kW1.52.24.05.55.57.511.0 15.0 18.5 22.022.0 380 ~ 400V kW 3.0 4.0 5.5 7.5 11.0 15.0 22.0 22.0 37.0 37.0 45.0 415 ~ 440V kW 3.0 4.0 5.5 7.5 11.0 15.0 22.0 22.0 37.0 37.0 45.0 500V kW 3.0 4.0 5.5 7.5 11.015.0 22.022.0 37.0 37.0 45.0 660 ~ 690V kW 4.0 5.5 7.5 7.5 15.0 18.5 22.0 30.0 37.0 45.0 55.0 RATED AC-4 OPERATING CURRENT, le (Achieves maximum of 1,000,000 operations) 220 ~ 240V A 2.73.65.57.69.712.115.2 19.7 24.2 28.831.8 380 ~ 400V A 2.73.65.57.69.712.115.2 19.7 24.2 28.831.8 415 ~ 440V A 2.73.65.57.69.712.115.2 19.7 24.2 28.831.8 500V A 2.33.24.25.87.39.711.5 16.7 19.1 23.925.8 660 ~ 690V A 2.12.73.94.56.77.610.3 13.3 14.5 18.224.2 RATED AC-4 OPERATING POWER, Pe (Achieves maximum of 1,000,000 operations) 220 ~ 240V kW0.550.751.11.5 2.23.0 4.04.0 5.5 7.5 7.5 380 ~ 400V kW1.11.52.23.04.05.55.57.511.0 11.015.0 415 ~ 440V kW1.11.52.23.04.05.55.57.511.0 11.015.0 500V kW1.11.52.23.04.05.55.57.511.0 11.015.0 660 ~ 690V kW1.51.53.03.05.55.57.511.0 11.0 15.022.0 RATED SHORT-TIME CURRENT, lcw 1 Second A 455 455 570 630 1010 1265 1580 2530 2530 3300 3300 5 Seconds A 205 205 254 280 450 450 710 1130 1130 1485 1485 10 Seconds A 144 144 180 200 320 400 500 800 800 1050 1050 30 Seconds A 85 85 104 115 185 230 290 460 460 600 600 1 Minute A 60 60 74 80 130 165 205 325 325 430 430 3 Minutes A 35 35 46 50 90 100 120 185 185 250 250 Short Circuit Protection with Fuses (gG/gL) Ue ≤ 690V Type 1 A 50 50 63 63 100 125 200 200 200 250 250 Type 2 A 25 35 35 50 63 80 100 125 125 160 200 MAXIMUM ELECTRICAL SWITCHING RATE AC-1 Ops./hr. 1200 1200 1200 1200 1200 1200 1200 1200 1200 600 600 AC-3 Ops./hr. 1200 1200 1200 1200 1200 1200 1200 1200 1200 600 600 AC-4 Ops./hr. 360 360 360 360 360 200 200 200 200 200 200 Electrical Endurance, AC-3 at Maximum Rated 3 Phase Ops. 1.6 1.8 1.3 1.4 1.3 1.3 1.2 1.4 1.2 1.2 1.0 Operating Power (@400V) (mill.) Making Capacity A 450 450 450 450 550 550 1000 1000 1000 1280 1280 BREAKING CAPACITY Ue ≤ 400V A 250 250 250 250 450 450 920 920 920 1050 1050 Ue = 500V A 250 250 250 250 450 450 920 920 920 1050 1050 Ue = 690V A 130 130 130 130 170 205 780 780 780 950 950 COIL CHARACTERISTICS Rated Insulation Voltage, Ui V 1000 OPERATING LIMITS 50HZ, 60HZ, 50/60HZ Operating xUc 0.80 ~ 1.10 Pick-Up xUc 0.60 ~ 0.60 ~ 0.60 ~ 0.60 ~ 0.60 ~ 0.60 ~ 0.65 ~ 0.65 ~ 0.65 ~ 0.65 ~ 0.65 ~ 0.80 0.800.800.800.800.800.800.800.800.80 0.80 Drop-Out xUc 0.35 ~ 0.35 ~ 0.35 ~ 0.35 ~ 0.40 ~ 0.40 ~ 0.40 ~ 0.40 ~ 0.40 ~ 0.40 ~ 0.40 ~ 0.55 0.550.550.550.600.60 0.600.600.600.60 0.60 300 300 310 310 45 WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. se s rei rei s es se s rei rei s es se s rei rei s es non-reversing non-reversing reversing reversing /S TB GR 300 310 310 1 1 6 61 1 3 3 DS DS EC EC TB GR PS PS 300 se s rei rei s es se s rei rei s es se s rei rei s es se s rei rei s es se s rei rei s es se s rei rei s es pecifications i ei ce c Contactors MECHANICAL, ENVIRONMENTAL AND CONSTRUCTION SPECIFICATIONS S09 S12 S18 S25 S32 S40 S50 S65 S80 S95 S105 COIL CHARACTERISTICS (CONTINUED) se s rei rei s es se s rei rei s es se s rei rei s es DC Operating xUc 0.80 ~ 1.10 ne n0.45 m em a miniature miniature Pick-Up xUc 0.45 ~ 0.45 ~ ~ a 0.45 ~ 0.45 ~ 0.45 ~ 0.70 ~ 0.70 ~ 0.70 ~miniature 0.70 ~ 0.70 ~miniature 0.65 0.650.650.650.750.750.80 0.800.800.80 0.80 Drop-Out xUc 0.15 ~ 0.15 ~ 0.15 ~ 0.15 ~ 0.15 ~ 0.15 ~ 0.40 ~ 0.40 ~ 0.40 ~ 0.40 ~ 0.40 ~ 0.30 0.300.300.300.300.300.60 0.600.600.60 0.60 se s rei rei s es COIL CONSUMPTION 50HZ, 60HZ, 50/60HZ Pick-Up VA 50 ~ 70 50 ~ 70 50 ~ 70 50 ~ 70 70 ~ 90 70 ~ 90 250 ~ 275 250 ~ 275250 ~ 275 250 ~ 275 250 ~ 275 Hold-In VA 7 ~ 11 7 ~ 11 7 ~ 11 7 ~ 11 9 ~ 13 9 ~ 13 16 ~ 20 16 ~ 20 16 ~ 20 16 ~ 20 16 ~ 20 DC Pick-Up W 5 ~ 9 5 ~ 9 5 ~ 9 5 ~ 9 7 ~ 10 7 ~ 10 340 340 340 340 340 Hold-In W 5 ~ 9 5 ~ 9 5 ~ 9 5 ~ 9 7 ~ 10 7 ~ 10 6.5 6.5 6.5 6.5 6.5 OPERATING TIMES AC Pick-Up msec. 8 ~ 20 8 ~ 20 8 ~ 20 8 ~ 20 10 ~ 19 10 ~ 19 15 ~ 30 15 ~ 30 15 ~ 30 15 ~ 30 15 ~ 30 Drop-Out msec. 6 ~ 13 6 ~ 13 6 ~ 13 6 ~ 13 5 ~ 25 5 ~ 25 9 ~ 15 9 ~ 15 9 ~ 15 9 ~ 15 9 ~ 15 DC Pick-Up msec. 35 ~ 45 35 ~ 45 35 ~ 45 35 ~ 45 40 ~ 55 40 ~ 55 50 ~ 60 50 ~ 60 50 ~ 60 50 ~ 60 50 ~ 60 Drop-Out msec. 7 ~ 12 7 ~ 12 7 ~ 12 7 ~ 12 30 ~ 65 30 ~ 65 55 ~ 60 55 ~ 60 55 ~ 60 55 ~ 60 55 ~ 60 POWER DISSIPATION 50Hz, 60Hz, 50/60Hz W 2.6 2.62.62.64.34.3 8.08.08.08.0 8.0 POWER FACTOR Closedcosϕ 0.33 0.330.330.330.28 0.280.260.260.260.26 0.26 Opencosϕ 0.84 0.840.840.840.73 0.730.540.540.540.54 0.54 MECHANICAL UNITS Mechanical Endurance Ops. 10 (mill.) Maximum Mechanical Ops./ 9,000 Switching Rate hr. ENVIRONMENTAL Ambient Operating Temperature °C / °F -25 to +55 / -13 to +131 Ambient Storage Temperature °C / °F -55 to +80 / -58 to +176 Altitude m / ft. 3,000 / 9,792 CONSTRUCTION GENERAL Pollution Degree 3 333333333 3 INGRESS PROTECTION Main Terminals IP20 IP20 IP20 IP20*IP20*IP20*IP20*IP20*IP20*IP20* IP20* Coil Terminals IP20 IP20IP20IP20IP20IP20IP20IP20IP20IP20 IP20 Auxiliary Contact Terminals IP20 IP20IP20IP20IP20IP20IP20IP20IP20IP20 IP20 Weight kg 0.2950.2950.2950.2950.52 0.541.1051.12 1.13 1.45 1.47 lbs. 0.65 0.65 0.65 0.65 1.15 1.19 2.44 2.47 2.49 3.20 3.24 TB TB 300 300 310 310 TB TB *NOTE: With conductors connected. For RoHS compliance documentation by product, refer to www.c3controls.com. ROHS COMPLIANCE S09 - S25 S32 - S40 S50 - S80 S95 - S105 CONSTRUCTION CONDUCTOR CROSS-SECTIONS, MAIN TERMINALS UNITS MAIN TERMINAL CAPACITY Solid Stranded and Finely mm2 2 x 0.5 ~ 6 2 x 1 ~ 14 2 x 1 ~ 34 2 x 1 ~ 43 Stranded without End Sleeve AWG Wire AWG 2 x 20 ~ 10 2 x 18 ~ 6 2 x 16 ~ 2 2 x 16 ~ 1 Recommended Strip Length mm 8.5 10 13 15 in 5/16 3/8 1/2 9/16 Tightening Torque Lb-in. 8.8 ~ 16.9 22.1 ~ 26.6 35.4 ~ 53.1 44.3 ~ 57.5 Nm 1.0 ~ 1.9 2.5 ~ 3.0 4.0 ~ 6.0 5.0 ~ 6.5 Screwdriver Phillips nr. 2 Phillips nr. 2 Allen 4mm Allen 4mm WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. 46 se s rei rei s es se s rei rei s es non-reversing non-reversing reversing reversing se s rei rei s es se s rei rei s es 300 300 310 310 320 320 330 330 CS CS 620 620 630 630 300 300 310 310 se s rei rei s es se s rei rei s es Specifications / se s rei rei s es se s rei rei s es se s rei rei s es AUXILIARY CONTACTS SPECIFICATIONS INTERNAL AUXILIARY CONTACT CONTACT BLOCKS S09-S25 300-SFA & 300-SSA ELECTRICAL GENERAL miniature miniature miniature miniature UNITS Minimum Switching Capacity 5mA @ 17V Electrical Endurance Ops. (mill.) 1 Mechanical Endurance Ops. (mill.) 15 Non-Overlap Time msec. 1.5 Insulation Resistance MΩ >10 ELECTRICAL UL/CSA APPLICATIONS Rated Operating Voltage, Ue V 600 PILOT DUTY RATING AC A600 DC P600 Q600 ELECTRICAL IEC APPLICATIONS Rated Insulation Voltage, Ui V 1000 Rated Operating Voltage, Ue V 690 Rated Thermal Current, Ith for A 20 10 Ambient Temperature <55° C RATED AC-15 OPERATING CURRENT, le 110 ~ 120V A 10 6 220 ~ 240V A 10 6 380 ~ 400V A 6 4 415 ~ 450V A 5 3.5 500V A 4 2.5 600 ~ 690V A 2 1.5 RATED DC-13 OPERATING CURRENT, Ie 24V A 6 6 48V A 4 4 110V A 2 2 220V A 0.7 0.7 440V A 0.7 0.3 MAKING CAPACITY, Im AC-15/AC-11 Ue ≤ 400V A 250 90 50/60Hz DC-13/DC-11 Ue ≤ 220V A 250 90 BREAKING CAPACITY, Im AC-15/AC-11 Ue ≤ 400V A 250 60 50/60Hz DC-13/DC-11 Ue ≤ 220V A 2 0.95 Short Circuit Protection A 10 10 with Fuses (gG/gL) For RoHS compliance documentation by product, refer to www.c3controls.com. ROHS COMPLIANCE OPERATING POSITIONS 30° 30° 47 30° 30° 30° 30° WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. se s rei rei s es se s rei rei s es se s rei rei s es non-reversing non-reversing reversing reversing C TB/ GR 300 310 310 1 1 6 61 1 3 3 DS DS EC EC TB GRDPS PS 300 se s rei rei s es se s rei rei s es se s rei rei s es se s rei rei s es se s rei rei s es se s rei rei s es ircuit iagrams i ei ce c Contactors S E R I E S 3 0 0 N O N - R E V E R S IsNesG Ce O N T A C T O R C I R C U I T Ds IesAreiG R AMS rei rei s s rei s es se s rei rei s es TB TB ne nm em a a POWER CIRCUIT 300 300 310 310 miniature miniature CONTROL CIRCUIT miniature miniature se s rei rei s es TB TB M1 F M2 R = Forward Contactor = Forward Push Button = Reverse Contactor = Reverse Push Button = Start Push Button = Emergency Stop Push Button = Coil Voltage Code SERIES 310 REVERSING CONTACTOR CIRCUIT DIAGRAMS CONTROL CIRCUIT POWER CIRCUIT 11 12 L1 L2 L3 CONTROL CIRCUIT CONTROL CIRCUIT POWER CIRCUIT POWER CIRCUIT 13 13 R F 14 1L1 3L2 5L3 1L1 3L2 M1 13 4T2 6T3 2T1 4T2 14 V 14 W 01 01 02 02 M1 A1 A1 A2 A2 M2 M1 M 3 13 6T3 M2 U M2 5L3 M2 2T1 14 M1 = Forward Contactor F = Forward Push Button = Reverse Contactor M1M2 = Forward Contactor F = Reverse Push Button M1R = Forward Contactor Push Button Contactor M2 F = Reverse Forward Push Button = Emergency Stop Push Button Contactor Push Button R M2 = Reverse = Coil Voltage Code Push Button Reverse Push Button R = Start = Emergency Stop Push Button Start Push Button Emergency = Coil VoltageStop CodePush Button = Coil Voltage Code WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. 48 se s rei rei s es se s rei rei s es non-reversing non-reversing reversing reversing se s rei rei s es se s rei rei s es miniature miniature miniature miniature 300 300 310 310 320 320 330 330 CS CS 620 620 630 630 se s rei rei s es UTILIZATION 1. Identify the utilization category of the application. 3**-S09 To find a contactor’s estimated life: 10 se s rei rei s es CATEGORY 3**-S32 3**-S40 3**-S50 3**-S65 3**-S80 3**-S95 3**-S105 IN 3**-S25 LIFE se s rei rei s es 3**-S18 ELECTRICAL 300 300 310 310 se s rei rei s es 3**-S12 se s rei rei s es Electrical Life / AC-1 10 25 32 45 60 90 110 140 100 Breaking Current Ie (A) 3**-S65 3**-S80 3**-S95 3**-S105 1 3**-S40 3**-S50 0.1 3**-S32 The life-load curves are based on tests in accordance with IEC 60947-4-1. Many conditions of an actual application effect contact life such as the environment and duty cycle. Therefore, the actual contact life may vary from the life indicated by the curves shown here. 3**-S12 3**-S18 3**-S25 4.Read the estimated contactor life from the vertical axis of the chart. 1 3**-S09 3.Locate the intersection of the life-load curve for the contactor selected with the application breaking current (Ie) on the horizontal axis of the chart. Electrical Life (106) 2.Refer to the chart for the applicable utilization category. AC-3 10 Electrical Life (106) NOTE: ** Represents the Non-Reversing or Reversing Contactor Code. Refer to pages 35 & 37. 1 0.1 18 25 32 40 50 65 8095105 Breaking Current le (A) 3**-S65 3**-S80 3**-S95 3**-S105 12 3**-S40 3**-S50 3**-S32 3**-S12 3**-S18 3**-S25 3**-S09 9 AC-4 Electrical Life (106) 10 1 0.1 49 30 42 48 72 96 138 222 300 500 110 180 264 400 600 Breaking Current le (A) WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. series 63mm s e r i e(2-31/64”) s series series 114mm s(4-31/64”) eries 85mm (3-11/32”) non-reversing /D 22 16 13 DS EC TB GR PS 300 series series series series iec iec 22 3 P O LE N ON - R E V E RS ING - TB A C C O I L Sseries 300 300-S09, 300-S12, 300-S18 & 300-S25 nema 93mm 3-85/128”) 75mm (2-61/64”) C ON T A C T 81mm OR S s e r i e s (3-3/16”) Contactors series 45mm imensions (1-99/128”) 9mm (23/64”) 114mm 114mm (4-31/64”) (4-31/64”) 85mm 85mm (3-11/32”) (3-11/32”) 63mm 63mm (2-31/64”) (2-31/64”) 45mm 45mm (1-99/128”) (1-99/128”) 9mm 9mm (23/64”) (23/64”) nema miniature 35mm (1-3/8”) series TB 9mm (23/64”) 73mm 127mm (5”) 98mm (3-55/64”) (2-7/8”) 4.7mm 55mm (3/16”) (2-21/128”) 72.5mm (2-109/128”) 81mm 81mm (3-3/16”) (3-3/16”) 87mm (3-27/64”) 35mm 35mm (1-3/8”) (1-3/8”) 4.5mm (23/128”) 10mm (25/64”) 300-S32 & 300-S40 73mm 73mm (2-7/8”) (2-7/8”) 9mm 55mm 9mm 4.7mm 55mm 4.7mm(2-21/128”) (23/64”)(3/16”) (2-21/128”) (23/64”) 89mm (3-65/128”) 127mm 127mm (5”)(5”) 98mm 98mm (3-55/64”) (3-55/64”) (3/16”) 72.5mm 72.5mm (2-109/128”) (2-109/128”) 9mm (23/64”) 45mm 84mm (1-99/128”) (3-5/16”) 16.5mm (83/128”) 87mm 87mm (3-27/64”) (3-27/64”) 4.5mm 4.5mm (23/128”) (23/128”) 10mm 10mm (25/64”) (25/64”) 84mm (3-5/16”) 16.5mm 16.5mm 9mm (83/128”) 66mm (83/128”) (23/64”) (2-77/128”) 12.5mm 12.5mm (63/128”) (63/128”) 112mm (4-13/32”) 78mm (3-5/64”) 116.5mm (4-75/128”) 112mm 12.5mm (4-13/32”) (63/128”) 89mm 89mm (3-65/128”) (3-65/128”) 45mm 45mm (1-99/128”) (1-99/128”) 4.5mm (23/128”) 300-S50, 300-S65 & 300-S80 78mm 78mm (3-5/64”) (3-5/64”) 144mm (5-43/64”) 115mm (4-17/32”) 66mm (2-77/128”) 70mm (2-97/128”) 58mm (2-37/128”) 56mm (2-13/64”) 144mm (5-43/64”) 115mm (4-17/32”) 4.5mm 4.5mm 116.5mm (23/128”) (23/128”) (4-75/128”) 90mm (3-35/64”) 5.5mm (7/32”) 6mm (15/64”) 7.5mm (19/64”) 9mm (23/64”) 70mm (2-97/128”) 93mm 58mm (3-85/128”) (2-37/128”) 75mm 56mm (2-61/64”) (2-13/64”) 70mm (2-97/128”) 58mm (2-37/128”) 56mm (2-13/64”) 300-S9570mm & 300-S105 (2-97/128”) 58mm (2-37/128”) 155mm (6-13/128”) 93mm 56mm 126mm (3-85/128”) (2-13/64”) 9mm (4-123/128”) 75mm (23/64”) (2-61/64”) 90mm (3-35/64”) 90mm (3-35/64”) 114.5mm (4-65/128”) 7.5mm (19/64”) 5.5mm (7/32”) 7.5mm 5.5mm (19/64”) (7/32”) 6mm (15/64”) 90mm 6mm (3-35/64”) (15/64”) 122mm (4-103/128”) 114.5mm 5.5mm (4-65/128”) (7/32”) 7.5mm (19/64”) 6mm (15/64”) 70mm 155mm (2-97/128”) (6-13/128”) 58mm 126mm (2-37/128”) (4-123/128”) 56mm (2-13/64”) 122mm 90mm (4-103/128”) (3-35/64”) 5.5mm (7/32”) 6mm (15/64”) 122mm (4-103/128”) 7.5mm (19/64”) WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. 50 ”) series series 63mm 300 310 320 330 CS 620 630 Dimensions / 3 series 45mm (1-99/128”) s35mm eries series (1-3/8”) 4.5mm (23/128”) 4.7mm (3/16”) 72.5mm (2-109/128”) 81mm (3-3/16”) Ps O LE N ON - R E V E R S ING eries 300 310 miniature 9mm (23/64”) reversing non-reversing series s e r(2-31/64”) ies series C ONTA C TOR S D C C OI L S 10mm 300-S09, 300-S12, 300-S18 & 300-S25 (25/64”) miniature 63mm (2-31/64”) 9mm (23/64”) 45mm (1-99/128”) 4.7mm (3/16”) 35mm 144mm 63mm (1-3/8”) (5-43/64”) (2-31/64”) 115mm 4.5mm 9mm 45mm (4-17/32”) (23/64”)(23/128”)(1-99/128”) 35mm (1-3/8”) 72.5mm (2-109/128”) 81mm (3-3/16”) 10mm (25/64”) 144mm (5-43/64”) 115mm (4-17/32”) 73mm 73mm (2-7/8”) (2-7/8”) 73mm 55mm (2-7/8”) 55mm (2-21/128”) (2-21/128”) 55mm (2-21/128”) 10mm (25/64”) 300-S32 & 300-S40 163mm 163mm (6-27/64”) (6-27/64”) 134mm163mm 134mm (5-9/32”) (6-27/64”) (5-9/32”) 134mm (5-9/32”) 144mm 45mm (5-43/64”) 45mm (1-99/128”) 115mm (1-99/128”) (4-17/32”) 45mm 16.5mm 16.5mm (83/128”) 84mm (83/128”) (3-5/16”) 16.5mm 9mm (83/128”) 66mm (23/64”) 87mm 87mm (3-27/64”) (3-27/64”) 87mm (3-27/64”) 4.5mm (23/128”) 4.7mm (3/16”) 72.5mm (2-109/128”) 81mm (3-3/16”) 9mm 9mm (23/64”) (23/64”) 9mm (23/64”) - 89mm 89mm (3-65/128”) (3-65/128”) 89mm (3-65/128”) (1-99/128”) 78mm 78mm (3-5/64”) (3-5/64”) 78mm (3-5/64”) (2-77/128”) 12.5mm 12.5mm (63/128”) (63/128”) 112mm 12.5mm (4-13/32”)(63/128”) 144mm (5-43/64”) 115mm (4-17/32”) 116.5mm 4.5mm 4.5mm (23/128”) (4-75/128”) (23/128”) 4.5mm (23/128”) 300-S50, 300-S65 & 300-S80 9mm (23/64”) 84mm (3-5/16”) 66mm (2-77/128”) 70mm (2-97/128”) 58mm (2-37/128”) 56mm (2-13/64”) 144mm (5-43/64”) 115mm (4-17/32”) 116.5mm (4-75/128”) 112mm (4-13/32”) 90mm (3-35/64”) 5.5mm (7/32”) 6mm (15/64”) 7.5mm (19/64”) 93mm (3-85/128”) 75mm (2-61/64”) 70mm (2-97/128”) 58mm (2-37/128”) 56mm 70mm(2-13/64”) (2-97/128”) 58mm 93mm (2-37/128”) (3-85/128”) 9mm 56mm 75mm (23/64”) 90mm(2-13/64”) (2-61/64”) (3-35/64”) 5.5mm (7/32”) 90mm 7.5mm (3-35/64”) 114.5mm (19/64”) (4-65/128”) 5.5mm (7/32”) m 8”) 7.5mm (19/64”) 51 300-S95 & 300-S105 70mm (2-97/128”) 58mm 155mm (2-37/128”) (6-13/128”) 93mm 56mm 126mm (2-13/64”) (3-85/128”) 9mm (4-123/128”) 75mm (23/64”) (2-61/64”) 70mm 155mm (2-97/128”) (6-13/128”) 58mm 126mm (2-37/128”) (4-123/128”) 56mm (2-13/64”) (4- 6mm (15/64”) 6mm (15/64”) 90mm (3-35/64”) 122mm (4-103/128”) 114.5mm 5.5mm (4-65/128”) (7/32”) 7.5mm (19/64”) 6mm (15/64”) 122mm 90mm (4-103/128”)(3-35/64”) 5.5mm (7/32”) 7.5mm (19/64”) WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. 6mm (15/64”) 122mm (4-103/128”) series series 114mm i m e n s i(4-31/64”) ons 85mm non-reversing (3-11/32”) series /D 300 310 16 13 DS EC TB GR PS series series series series s e r i e s 99mm s e r i e s (3-115/128”) 9mm 45mm (23/64”) (1-99/128”) iec reversing Contactors 81mm 3 P O L E C O N T A C T O R S (3-3/16”) W ITH ELECTRICAL/ ries eries series M E C H A N I C A L O R M E C H sAe N I C A L I N T E R L O C K - As C COILS TB 300 310 310-S09, 310-S12, n e m a310-S18 & 310-S25 99mm (3-115/128”) 9mm 45mm (23/64”) (1-99/128”) 114mm (4-31/64”) series 85mm (3-11/32”) miniature 18mm (91/128”) 4.7mm (3/16”) TB 35mm (1-3/8”) 119mm (4-11/16”) 9mm 55mm (23/64”) (2-21/128”) 72.5mm (2-109/128”) 81mm (3-3/16”) 87mm (3-27/64”) 4.7mm (3/16”) 35mm (1-3/8”) 119mm (4-11/16”) 9mm 55mm (23/64”) (2-21/128”) 87mm (3-27/64”) 16.5mm (83/128”) 4.5mm (23/128”) 19mm (3/4”) 45mm 45mm (1-99/128”) 141mm (1-99/128”) (5-71/128”) 9mm 66mm (23/64”) (2-77/128”) 4.5mm (23/128”) 19mm (3/4”) 310-S50, 310-S65 & 310-S80 4.5mm (23/128”) 70mm (2-97/128”) 58mm (2-37/128”) 56mm (2-13/64”) 144mm (5-43/64”) 144mm (5-43/64”) 115mm (4-17/32”) 115mm (4-17/32”) 116.5mm (4-75/128”) 116.5mm (4-75/128”) 90mm (3-35/64”) 6mm 5.5mm (15/64”) (7/32”) 7.5mm (19/64”) 70mm (2-97/128”) 70mm (2-97/128”) 58mm (2-37/128”) 58mm (2-37/128”) 56mm (2-13/64”) 56mm 159mm (2-13/64”) 114.5mm (4-65/128”) 114.5mm 114.5mm (4-65/128”) (4-65/128”) 17mm (43/64”) 310-S95 & 310-S105 70mm (2-97/128”) 70mm 70mm (2-97/128”) (2-97/128”) 58mm (2-37/128”) 58mm 58mm 56mm (2-37/128”) (2-37/128”) (2-13/64”) 56mm 56mm (2-13/64”) (2-13/64”) 155mm (6-13/128”) 155mm 155mm (6-13/128”) (6-13/128”) 126mm (4-123/128”) 126mm 126mm (4-123/128”) (4-123/128”) (6-17/64”) 159mm 159mm (6-17/64”) 9mm 75mm(6-17/64”) (23/64”) 9mm 9mm (2-61/64”) 75mm 75mm (23/64”) (23/64”) (2-61/64”) (2-61/64”) 90mm (3-35/64”) 90mm 6mm (3-35/64”) 6mm 5.5mm (15/64”) (7/32”) 5.5mm (15/64”) (7/32”) 7.5mm (19/64”) 7.5mm (19/64”) 144mm (5-43/64”) 115mm (4-17/32”) 116.5mm (4-75/128”) 112mm (4-13/32”) 12.5mm (63/128”) 45mm 45mm (1-99/128”) (1-99/128”) 141mm (5-71/128”) 141mm (5-71/128”) 9mm 66mm (23/64”) (2-77/128”) 9mm 66mm 78mm (2-77/128”) (23/64”) (3-5/64”) 112mm 12.5mm (4-13/32”) 112mm (63/128”) (4-13/32”) 16.5mm (83/128”) 78mm (3-5/64”) 89mm (3-65/128”) 10mm (25/64”) 4.5mm (23/128”) 310-S32 & 310-S40 127mm (5”) 98mm (3-55/64”) 72.5mm (2-109/128”) 127mm (5”) 98mm (3-55/64”) 89mm (3-65/128”) 10mm (25/64”) 18mm (91/128”) 35mm (1-3/8”) 35mm (1-3/8”) miniature 122mm (4-103/128”) 122mm 122mm (4-103/128”) (4-103/128”) 17mm (43/64”) 17mm (43/64”) 90mm (3-35/64”) 90mm 90mm (3-35/64”) (3-35/64”) 7.5mm (19/64”) 7.5mm 7.5mm (19/64”) (19/64”) 6mm (15/64”) 6mm 6mm 5.5mm (15/64”) (15/64”) (7/32”) 5.5mm 5.5mm (7/32”) (7/32”) 26mm (1-1/32”) 26mm 26mm (1-1/32”) (1-1/32”) WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT. 52 series 310 320 330 CS 620 630 series series series Dimensions / s e r i e s99mm (3-115/128”) series 3 series 310 9mm (23/64”) 45mm (1-99/128”) reversing 144mm (5-43/64”) 115mm (4-17/32”) 81mm P O L E C O N T A C T O R S W I T H E L E C (3-3/16”) TRICAL/MECHANICAL OR MECHANICAL INTERLOCK - DC COILS 310-S09, 310-S12, 310-S18 & 310-S25 miniature 99mm (3-115/128”) 45mm (1-99/128”) 18mm (91/128”) 144mm (5-43/64”) 9mm (23/64”) 4.7mm (3/16”) 115mm (4-17/32”) 35mm (1-3/8”) 35mm (1-3/8”) 119mm (4-11/16”) 87mm 10mm (3-27/64”) (25/64”) 18mm (91/128”) 4.7mm (3/16”) 35mm (1-3/8”) 35mm (1-3/8”) 87mm (3-27/64”) 10mm (25/64”) 112mm (4-13/32”) 78mm (3-5/64”) 45mm (1-99/128”) 112mm 12.5mm (4-13/32”) 112mm (63/128”) (4-13/32”) 4.5mm (23/128”) 12.5mm (63/128”) 310-S50, 310-S65 & 310-S80 45mm (1-99/128”) 144mm (5-43/64”) 115mm (4-17/32”) 116.5mm (4-75/128”) 116.5mm (4-75/128”) 4.5mm116.5mm (4-75/128”) (23/128”) 70mm (2-97/128”) 58mm (2-37/128”) 56mm (2-13/64”) 144mm (5-43/64”) 144mm (5-43/64”) 115mm (4-17/32”) 115mm (4-17/32”) 141mm (5-71/128”) 141mm 9mm 66mm (5-71/128”) (23/64”) (2-77/128”) 9mm 66mm (23/64”) (2-77/128”) 45mm (1-99/128”) 141mm (5-71/128”) 9mm (23/64”) 89mm (3-65/128”) 4.5mm (23/128”) 45mm (1-99/128”) 16.5mm (83/128”) 78mm 66mm (3-5/64”) (2-77/128”) 19mm (3/4”) 16.5mm (83/128”) 90mm (3-35/64”) 6mm 5.5mm (15/64”) (7/32”) 7.5mm (19/64”) 114.5mm (4-65/128”) 114.5mm (4-65/128”) 70mm (2-97/128”) 70mm 58mm (2-97/128”) (2-37/128”) 58mm (2-37/128”) 56mm (2-13/64”) 56mm (2-13/64”) 159mm (6-17/64”) 159mm 75mm(6-17/64”) 9mm (23/64”) 90mm (2-61/64”) 9mm 75mm (3-35/64”) 90mm (23/64”) (2-61/64”) 6mm (3-35/64”) 5.5mm (15/64”) 6mm (7/32”) 5.5mm (15/64”) (7/32”) 7.5mm (19/64”) 7.5mm (19/64”) 89mm (3-65/128”) 19mm (3/4”) 147mm (5-101/128”) 118mm (4-83/128”) 9mm (23/64”) 55mm 72.5mm (2-21/128”) (2-109/128”) 4.5mm (23/128”) 310-S32 & 310-S40 119mm (4-11/16”) 147mm (5-101/128”) 118mm (4-83/128”) 9mm (23/64”) 55mm 72.5mm (2-109/128”) (2-21/128”) 81mm (3-3/16”) 310-S95 & 310-S105 155mm 70mm (2-97/128”) 70mm (2-97/128”) 58mm (2-37/128”) 58mm 56mm (2-37/128”) (2-13/64”) 56mm (2-13/64”) (6-13/128”) 155mm 126mm (6-13/128”) (4-123/128”) 126mm (4-123/128”) 122mm 17mm (43/64”) 122mm 17mm(4-103/128”) (4-103/128”) (43/64”) 17mm (43/64”) 90mm (3-35/64”) 90mm (3-35/64”) 7.5mm (19/64”) 7.5mm (19/64”) 6mm (15/64”) 6mm 5.5mm (15/64”) (7/32”) 5.5mm (7/32”) 26mm (1-1/32”) 26mm (1-1/32”) VI SI T WWW.C 3 C ONT R O L S.CO M TO DOWNLOAD C AD DR A W I N G S 53 WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
Similar documents
Cataloque 2 (Accessorie)
PEDAL PAD SETS & GEAR LEVER KNOBS PRACTICAL, QUALITY ACCESSORIES PEDAL PAD SETS - ALUMINIUM BODY
More information