330 320 S 300e s 310 320 PS R 300 310

Transcription

330 320 S 300e s 310 320 PS R 300 310
s 23-B
esrei r
e ise s
esrei r
e ise sEdition
s esrei r
e ise s
s esrei r
e ise s
non-reversing
non-reversing
reversing
reversing
TB GR
300 310
310 3
EC
EC TB
GR PS
PS 300
s esrei r
e ise s
s esrei r
e ise s
i e ice c
c3controls’ new line of Contactors are easy to install and designed to perform in a broad range of global applications. Our
Series 300 Non-Reversing and Series 310 Reversing Contactors feature DIN rail and panel mounting, IP20 guarded terminals,
multi-point coils, and include a wide variety of shared accessories.
s esrei r
e ise s
TB
TB
s esrei r
e ise s
s esrei r
e ise s
miniature
miniature
miniature
miniature
300
300 310
310
n enm
em
a a
CONTACTORS
s esrei r
e ise s
TB
TB
Series 300 Non-Reversing37
Series 310 Reversing39
Accessories41
Replacement Components43
Specifications44
Circuit Diagrams48
Electrical Life49
Dimensions50
PROVEN
Conformity to Standards:
UL 508, 60947-4-1A
CSA C22.2 No. 14
IEC 60947-1, 60947-4-1
Certifications:
UL File #: E236197 (Guide NLDX, NLDX7), E68568 (Guide NKCR, NKCR7)
CE Marked (per EU Low Voltage Directive 2006/95/EC and
RoHS Directive 2011/65/EU)
Visit www.c3controls.com to download product certifications.
NOTE: The scope (range, description, price, specifications, dimensions, etc.) of the product featured in this
section is subject to change without notice. Refer to www.c3controls.com for product updates.
s
se
s rei rei s
es
se
s rei rei s
es
non-reversing
non-reversing
reversing
reversing
300
300 310
310 320
320 330
330 CS
CS 620
620 630
630
se
s rei rei s
es
se
s rei rei s
es
Contactors /
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
CONTACTORS
300
300 310
310
se
s rei rei s
es
se
s rei rei s
es
miniature
miniature
miniature
miniature
c3controls offers a comprehensive line of Motor Control products designed and manufactured to meet
the needs of the machine builder. We promise durable products at a price that gives you an edge, and we
guarantee same-day shipping. Check out all the features of our Series 300/310 standard contactors below!
DELIVERING SUPERIOR PRODUCT QUALITY AND MANUFACTURING EXCELLENCE
Proven
Our Series 300 and 310 Standard Contactors are UL Listed and CE marked,
meeting global standards requirements.
Compact Size
Reduced panel area for lower installed costs—Four (4) frame sizes directly interchangeable
with other manufacturers.
Lower Cost
Snap-on front mounted and side mounted auxiliary contacts install without the use of tools for
lower installed costs.
Convenient
Wide variety of AC and DC operating coils for control circuit application flexibility.
50A to 105A DC operated devices feature electronic coil control.
Easy to Install
35mm DIN rail mounting for all contactors from 9A to 105A for fast and easy installation
and removal, or panel mounting for more secure installation in high shock and vibration
applications.
Modular Design
Modular design allows easy installation of Series 320 Overload Relays and the complete
range of Series 330 Motor Protection Circuit Breakers and accessories.
Visible Certifications
Our product certifications and electrical ratings are clearly marked on the outside of the
device for easy reference during installation.
Environmentally Friendly
Environmentally friendly contacts are cadmium free and non-metallic materials are asbestos,
halogen, and cadmium free. All c3controls products are compliant to the RoHS directives.
Added Safety
IP20 guarded terminals with dual terminal markings prevent accidental contact with live parts.
Lifetime Warranty*
Every product is backed by our lifetime warranty—unmatched in the industry—bringing
you quality components that perform in the most demanding applications.
Guaranteed Same-Day
Shipping*
Product availability reduces inventory, and improves cash-flow—saving you money. With c3controls
any order for standard catalog items received by 6:00pm ET is guaranteed to ship same-day.
Advantage Pricing
Our approach to product development, manufacturing, and focus on servicing the OEM and
Electrical Equipment Builder reduces cost. The result—the best value in the industry.
*See c3controls Terms & Conditions
“
When GinSan expanded to Canada, we needed to find a supplier that could provide us with motor
protection products that conformed to Canadian standards without increasing our bottom line. During
the evaluation and testing of a new supplier, c3controls motor control products met all of our quality
standards. One added feature c3controls offers on their contactors is they have an extra, fourth
contact—eliminating the need to add an extra auxiliary onto the device.
Mike Fox, Engineering Chief · GinSan Industries Inc.
33
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
”
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
i ei ce c
non-reversing
non-reversing
reversing
reversing
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
miniature
miniature
miniature
miniature
/C
TB GR
300 310
310
1
1
6
61
1
3
3 DS
DS EC
EC TB
GR
PS
PS 300
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
ontactors
Reversing Contactor
ne
nm
em
a a
Contactors
TB
TB
Non-Reversing Contactor
300
300 310
310
se
s rei rei s
es
TB
TB
UNIQUE PRODUCT LINE FEATURES
HIGH FAULT SCCR
INTEGRAL AUXILIARY
SEAMLESS COMPATIBILITY
High fault short circuit current rating of 100kA
@ 480V and 600V with Class J fuses, provides
safety and reliability in high fault applications.
Integral auxiliary contacts, 3 power poles + 1
auxiliary, are standard on all c3controls 9A to
25A non-reversing contactors.
c3controls Series 310, 9A to 25A, AC/DC Reversing
Contactors are compatible with directly mounted
Series 320-B2 Overload Relays, and our 9A to 40A
AC/DC Reversing Contactors direct mount onto
Series 330 Motor Protection Circuit Breakers.
COMMON ACCESSORIES
MULTI-POINT TERMINAL COILS
QUICK IDENTIFICATION
Four terminal coils on all 9A to 105A AC and DC
operated contactors are easily accessible, two on
the line side and two on the load side.
Enhanced markings, improved identification
labels, and dual IEC and NEMA terminal
markings ensure quick identification of product
from all angles simplifying troubleshooting in
panels with many devices.
Designing starter assemblies and panels is easy!
No more remembering which auxiliary works with
each contactor. Our complete range of Series 300
Non-Reversing and Series 310 Reversing Contactors
shares common accessories reducing inventory
and simplifying installation and assembly.
FIND IT
FAST
Contactors
•
•
•
•
•
Certifications
Specifications
Dimension Drawings
Installation Instructions
Easy to Buy
www.c3controls.com
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
34
se
s rei rei s
es
se
s rei rei s
es
non-reversing
non-reversing
reversing
reversing
se
s rei rei s
es
se
s rei rei s
es
miniature
miniature
miniature
miniature
300
300 310
310 320
320 330
330 CS
CS 620
620 630
630
se
s rei rei s
es
se
s rei rei s
es
Contactors /
300
300 310
310
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
Motor Control Device
Solutions
c3controls motor control devices are the perfect solution for
manufacturers who want proper motor control and superior motor
protection without having to overpay or compromise on quality. In fact,
we engineer so much performance and flexibility into our products,
we can deliver a remarkably better value than our competitors.
c3controls
products deliver
like no other.
Seamless Compatibility
Contactors, overload relays and motor protection circuit breakers are designed by
c3controls to work together, with common connections and accessories, resulting in a
high functioning compact starter.
LEADING THE INDUSTRY
with our compact miniature 10HP
contactors and control relays.
One frame size (AC or DC)—28%
reduction in panel area.
Compact
The small size of c3controls motor control devices, plus features like common accessories,
enable assembly into smaller control panels for lower installed costs.
Reliable Protection
Contactors provide the repeated on/off switching for the motor and are designed for
motor, actuator, solenoid, and other power switching applications. Overload relays provide
Trip Class 10 protection against overload and phase-loss conditions, and have ambient
temperature compensation for motor protection in high temperature environments.
Ensures the protection of
equipment and user.
Motor protection circuit breakers provide overload, phase-loss and short circuit protection,
can be used by themselves as manual motor controllers or with contactors in group motor
installations, and can achieve Type 2 coordination for optimum performance.
Type E self-protected combination manual motor controllers provide disconnecting means,
branch circuit protection, motor control and motor overload protection all in a single device.
Proven
Our motor control devices are UL Listed and CE marked, meeting global standards
requirements for use anywhere in the world.
35
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
non-reversing
non-reversing
reversing
reversing
se
s rei rei s
es
se
s rei rei s
es
miniature
miniature
miniature
miniature
/C
TB GR
300 310
310
1
1
6
61
1
3
3 DS
DS EC
EC TB
GR
PS
PS 300
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
ontactors
i ei ce c
se
s rei rei s
es
ne
nm
em
a a
Contactors
NFPA 70 TB
TB(NEC)
National Electrical Code
300
300 310
310
Understanding what functions are needed in your motor control circuit
se
s rei rei s
es
is critical when selecting motor control devices. Engineers benefit from
the standards and codes established to ensure safety and protection to
personnel and equipment.
TB
TB
More than just knowing the standards, c3controls, as a manufacturer of
motor control products, has the application expertise you need to select
the right products.
c3controls & Article 430 - Motors, Motor Circuits and Controllers
To Supply
Motor
disconnecting
means
NEC Part
c3controls Product Series
Part IX
330
Motor branchcircuit, short circuit,
and ground-fault
protection
Part IV
Motor circuit
conductor
Part II
Motor controller
Part VII
Type E: 330 630
Type E: 330 630
Motor control
circuits
Part VI
Motor overload
protection
Part III
Motor
630
300/310
330
620
630
Type E: 330 630
320
330
620
630
Type E: 330 630
Our motor
control products
align with Article
430 Part VII,
Motor Controller,
of the NFPA 70,
the National
Electrical Code.
Part I
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
36
series
series
300 310 320 330 CS 620 630
series
N o n -R e v e r s i n g /
non-reversing
reversing
series
series
IT’S
300 310
EASY
TO
series
BUILD
series
YOUR
series
OWN
series
CONTACTOR
Simply pick the code number from each of the sections below and combine
tominiature
build your part number.
them
miniature
Non-Reversing Contactors
I IIIII
Example: To build one of our most popular Contactors,
the part number would be I + II + III o r 3 0 0 - S 09N30D 10
I. NON-REVERSING CONTACTORS (3 NORMALLY OPEN POLES)
RATINGS FOR SWITCHING AC MOTORS - AC-2, AC-3
kW (50Hz)
HP (60Hz)
MAX. le (A)
3 PHASE
1 PHASE
3 PHASE
CODE
AC-3 AC-1 230V
400/415V
500V690V 115V230V 200V230V 460V575V
PRICE
300-S09N30
9
25
2.2
4
5.5
5.5
1/2
1-1/2
3
3
5
7-1/2 $ 53.00
300-S12N30
12
25
3
5.5
7.5
7.5
3/4
2
3
3
7-1/2
10
$ 79.00
300-S18N30 1832 4 7.5 1010 1 3 5 5 1015
$ 87.00
300-S25N30 25457.5 11 1515 2 37-1/2
7-1/21515
$ 99.00
300-S32N30 3260 9 1518.5
18.5 3 5 1010 2025
$130.00
300-S40N30 4060 1118.52530 3 5 1015 3025
$178.00
300-S50N30 5090 15 22 3035 37-1/21515 4040
$212.00
300-S65N30 6511018.530 4045 510 2020 5050
$236.00
300-S80N30 8011022 37 45457-1/2
15 2025 5060
$271.00
300-S95N30 9514025 45 55557-1/2
15 2530 6075
$346.00
300-S105N30105
140305565651020 30407575
$398.00
II. COIL VOLTAGE CODE
AC COIL VOLTAGE CODES
VOLTAGE 12 24 48 110120 208220230240277380400400 ~ 415440480500 550600
50Hz G H K D——M———QAM R S—T U—
60Hz B C J—D L——F P—— — —R——T
50/60Hz XB XCXJXDXAD—XAJXNXF——
XAM — XQ—— ——
DC COIL VOLTAGE CODES
PRICE
VOLTAGE
12
24
24 ~ 28
48
42 ~ 50
110
125
110 ~ 130
208 ~ 240 250
-S09 to -S25
ZB
ZC
—
ZK
—
ZD
ZQ
—
—
ZP
$ 35.00
-S32 to -S40
ZB
ZC
—
ZK
—
ZD
ZQ
—
—
ZP
$ 78.00
-S50 to -S105
—
—
EC
—
EK
—
—
EL
EE
—
$282.00
III. AUXILIARY CONTACT CONFIGURATION
CODEDESCRIPTION
00
Without Auxiliary Contacts
(Contactors 300-S32 to 300-S105 only)
10
1 Normally Open* 01
1 Normally Closed*
PRICE
— $ 18.00
$ 18.00
DISC OUNT
SC HEDULE
*NOTE: Integral right side mounted on 9A ~ 25A contactors, front mounted on 32A ~ 105A contactors.
Some
of
Our Popular Configurations:
NON-REVERSING CONTACTORS
CATALOG NUMBER
300-S09N30D10
300-S09N30ZC10
300-S25N30D10
37
DESCRIPTION
Non-Reversing, 9A, 3 Pole, 120V AC Coil, 1 NO Auxiliary Contact
Non-Reversing, 9A, 3 Pole, 24V DC Coil, 1 NO Auxiliary Contact
Non-Reversing, 25A, 3 Pole, 120V AC Coil, 1 NO Auxiliary Contact
PRICE
$ 71.00
$106.00
$117.00
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
F
series
series
series
/ N -R
22 16 13 DS EC TB GR
PS 300
series
series
series
series
series
on
iec
22
nema
Non-Reversing Contactors
c3controls Series 300 Contactors are ideal for motor, actuator,
solenoid, and other power switching applications where panel
space is at a premium and device modularity is required to
satisfy virtually any application requirement. cULus and CE
Markings make them suitable for use anywhere in the world.
Small size, IP20 guarded terminals with dual terminal markings,
and shared accessories will help reduce your total installed costs
and enhance the features and performance of your equipment.
Just look and see what the Series 300 has to offer.
eversing
iec
non-reversing
series
series
TB
nema
series
TB
Contactors
series
series
300
miniature
Product features include:
• NEW – High fault short circuit rating of 100kA @ 480V and
600V with Class J fuses, provides safety and reliability in high
fault applications.
• NEW – Series 300 25A contactor has an integral auxiliary, 3 power
poles plus 1 auxiliary, provides more functionality in a smaller
package, reducing bill of material and panel size.
• IMPROVED – Removable and replaceable identification marker, standard on all
c3controls contactors and Series 300-SFA Auxiliaries, for labeling contactors and front mounted auxiliary
contacts - simplifies trouble shooting in panels with many contactors.
• IMPROVED – Our side mounted auxiliaries and interlocks are now 9mm wide and install without the use of tools onto Series 300
Contactors, reducing panel footprint and simplying installation.
• IMPROVED – Multi-point terminal coils on 9A to 80A AC and DC contactors providing wiring flexibility and installation convenience.
• IMPROVED – Lower power consumption for 32A and 40A DC contactors.
• IMPROVED – Enhanced markings and high visibility labels for ease of troubleshooting and maintenance.
• Compact size – four (4) frame sizes for devices rated from 9A to 105A. Contactors rated 15HP @ 460V (11kW @ 400V) are only
45mm (1-49/64”) wide reducing panel area requirements – smaller enclosures can be used for lower installed costs.
• AC and DC operating coils for control circuit application flexibility. 32A to 105A DC operated devices feature electronic coil control.
• Environmentally friendly contacts are cadmium free and non-metallic materials are asbestos, halogen, and cadmium free.
• IP20 guarded terminals prevent accidental contact with live parts.
• Dual IEC and NEMA terminal markings for ease of wiring anywhere in the world.
• 35mm DIN rail mounting for all contactors from 9A to 105A for fast and easy installation and removal or panel mounting
for more secure installation in high shock and vibration applications. Our 9A to 25A devices are easily installed or removed
without the use of tools.
• Modular design allows easy installation of Series 320 Overload Relays and the complete range of Series 330 Motor Protection
Circuit Breakers and accessories.
• Combination head terminal screws allow the use of straight, phillips, or posidrive screwdrivers. Allen head screws on
50A through 105A contactors make it easy to apply the proper terminal tightening torque for secure conductor connections.
• Snap-on front mounted auxiliary contacts install without the use of tools for lower installed costs. Single circuits available
so you only purchase what you need.
U N I Q U E
P ROD UC T
FEATU R ES
IMPROVED - Multi-Point Terminal Coils
Four terminal coils on all 9A to 105A AC and DC operated contactors are easily accessible on contactor
and overload relay assemblies or contactor and motor protection circuit breaker assemblies. The control
circuit can be wired from the line side or the load side of the contactor, whichever is most convenient
for the installation. Control circuit wire runs can be minimized, and the devices can be easily substituted
in your existing equipment without disturbing or changing your control wires. So no matter what
components are being used, Series 300 Contactors can be easily and quickly wired, reducing your labor
and installation costs.
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
38
series
310 320 330 CS 620 630
series
series
Reversing /
series
series
series
reversing
I T ’ S
E A S Y
T O
B U I LD
YOUR
OWN
C ONTA C TOR
series
310
Simply pick the code number from each of the sections below and
combine them to build your part number.
miniature
Reversing Contactors
I
II
III
IV
Example: To build one of our most popular Contactors,
the part number would be I + II + III + IV o r 310-S 25N30D 22
I. REVERSING CONTACTORS (3 NORMALLY OPEN POLES)
RATINGS FOR SWITCHING AC MOTORS - AC-2, AC-3
kW (50Hz)
HP (60Hz)
MAX. le (A)
3 PHASE
1 PHASE
3 PHASE
CODE
AC-3AC-1230V
400/415V
500V690V115V230V200V230V460V575VPRICE
310-S09N30 925
2.245.5
5.5
1/2
1-1/2
335 7-1/2
$214.00
310-S12N30 12
2535.57.5
7.5
3/4233
7-1/2
10
$266.00
310-S18N30 18
3247.51010135510
15
$282.00
310-S25N30 25457.511 15 15 2 37-1/2
7-1/21515
$342.00
310-S32N30 326091518.5
18.53 510102025
$415.00
310-S40N30 40601118.525303 5 10153025
$511.00
310-S50N30 50901522 303537-1/2
15154040
$625.00
310-S65N30 65110
18.530 40455 1020205050
$673.00
310-S80N30 801102237 4545
7-1/2
1520255060
$743.00
II. COIL VOLTAGE CODE
AC COIL VOLTAGE CODES
12 24 48 110120208220230240277380400400 ~ 415440480500 550600
G H K D ——M——— QAM R S — T U—
B C J—D L——F P—— — —R——T
XB XCXJXDXAD—XAJXNXF——
XAM — XQ—— ——
DC COIL VOLTAGE CODES
PRICE
VOLTAGE
12
24
24 ~ 28
48
42 ~ 50
110
125
110 ~ 130
208 ~ 240 250
-S09 to -S25
ZB
ZC
—
ZK
—
ZD
ZQ
—
—
ZP
$ 70.00
-S32 to -S40
ZB
ZC
—
ZK
—
ZD
ZQ
—
—
ZP
$157.00
-S50 to -S80
—
—
EC
—
EK
—
—
EL
EE
—
$563.00
VOLTAGE
50Hz
60Hz
50/60Hz
III. AUXILIARY CONTACT CONFIGURATION
CODEDESCRIPTION
PRICE
00
Without Auxiliary Contacts —
(Contactors 310-S32 to 310-S80 only)
22
2 Normally Open (1 NO on Forward Contactor1$ 47.00
and 1 NO on Reverse Contactor1) and 2 Normally
Closed (1 NC on Forward Contactor2 and 1 NC
on Reverse Contactor2)
IV. OPTIONS
CODE
DESCRIPTION
(Blank) With Power Wires
WW
Without Interconnecting Power Wires
FOR CONTACTOR
—
-S09 to -S25
-S32 to -S40
-S50 to -S80 -PRICE (deduct)
—
– $ 34.00
– $ 51.00
– $ 97.00
1 Integral right side mounted on 9A ~ 25A contactors, front mounted on
32A ~ 80A contactors.
2Integrated contacts as part of the electrical/mechanical interlock.
39
DISC OUNT
SC HEDULE
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
F
series
series
series
16 13 DS EC TB GR PS/ R 300 310
series
series
series
series
series
series
eversing
iec
reversing
series
series
miniature
miniature
Reversing Contactors
c3controls new Series 310 Reversing Contactors are ideal for reversing
in applications
s e r i e motors
s
where panel space is at a premium and device modularity is required to satisfy virtually any
application requirement. cULus and CE Markings make them suitable for use anywhere in
the world. A common mechanical interlock, power wiring modules,
n e mIP20
a guarded
terminals with dual terminal markings, and shared accessories help reduce your total
installed costs and enhance the features and performance of your equipment. Just look and
see what our new Series 310 has to offer.
TB
Contactors
non-reversing
300 310
series
TB
Product features include:
• NEW – High fault short circuit rating of 100kA @ 480V and 600V with Class J fuses,
provides safety and reliability in high fault applications.
• NEW – Series 300 25A contactor has an integral – auxiliary, 3 power poles
plus 1 auxiliary, provides more functionality in a smaller package, reducing bill of material and panel size.
• IMPROVED – Modular design allows Series 320-B2 Overload Relays to be directly mounted onto
Series 310, 9A to 25A, reversing contactors resulting in a high functioning compact starter.
• IMPROVED – Removable and replaceable identification marker, standard on all c3controls contactors,
simplifies troubleshooting in panels with many devices.
• IMPROVED – Multi-point terminal coils on 9A to 80A AC and DC contactors providing wiring flexibility and installation convenience.
• IMPROVED – Lower power consumption for 32A and 40A DC contactors.
• IMPROVED – Series 330 Motor Protection Circuit Breakers direct mount onto Series 310, 9A to 40A AC and DC, reversing contactors,
resulting in a high functioning compact starter.
• Modular design allows use with separately mounted overload relays, or Series 320 Overload Relays can be directly mounted on Series 310
32A to 50A reversing contactors without load-side interconnecting power wires.
• AC and DC operating coils for control circuit application flexibility. 50A to 80A DC operated devices feature electronic coil control.
• Environmentally friendly contacts are cadmium free and non-metallic materials are asbestos, halogen and cadmium free.
• IP20 guarded terminals prevent accidental contact with live parts.
• Dual IEC and NEMA terminal markings for ease of wiring anywhere in the world.
• Device identification marker for labeling contactors and front mounted auxiliary contacts simplify trouble shooting in panels
without the use of tools.
• Power wiring modules provide reliable, rigid interconnections between the forward and reverse contactors.
• Combination head terminal screws allow the use of straight, phillips, or posidrive screwdrivers. Allen head screws on
50A through 80A contactors make it easy to apply the proper terminal tightening torque for secure conductor connections.
• Snap-on front mounted auxiliary contacts install without the use of tools for lower installed costs. Single circuits available
so you only purchase what you need.
UNIQUE
PRODUCT
FEATURES
Series 310 Reversing Contactors feature a single, side mounted electrical and mechanical
or mechanical only interlock that is used for the whole range of contactors, enabling a 9A
contactor to be interlocked with a 105A contactor. The side mounted interlock doesn’t increase
the depth of the contactor and doesn’t prevent front mounted auxiliary contacts from being
added to either the forward or reverse contactors. Contactors are physically secured together
with a dovetail bracket that installs from the bottom of the contactor – so it can’t fall out when
it is installed on a DIN rail or on a panel, even in high vibration applications. To complete
the reversing contactor assembly, attractive, insulated wiring modules provide error free
interconnections between the forward and reverse contactors. Simple to use, modular accessories
make reversing contactors easy to assemble in the field – or order them factory assembled. Either
way you’ll get the performance and features you need for your reversing motor applications.
Some
of
Our Popular Configurations:
REVERSING CONTACTORS
CATALOG NUMBER
310-S09N30D22
310-S09N30ZC22
310-S25N30D22
310-S25N30ZC22
310-S32N30D22
DESCRIPTION
Reversing, 9A, 3 Pole, 120V AC Coil, 2 NO and 2 NC Auxiliary Contacts
Reversing, 9A, 3 Pole, 24V DC Coil, 2 NO and 2 NC Auxiliary Contacts
Reversing, 25A, 3 Pole, 120V AC Coil, 2 NO and 2 NC Auxiliary Contacts
Reversing, 25A, 3 Pole, 24V DC Coil, 2 NO and 2 NC Auxiliary Contacts
Reversing, 32A, 3 Pole, 120V AC Coil, 2 NO and 2 NC Auxiliary Contacts
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
PRICE
$261.00
$331.00
$389.00
$459.00
$462.00
40
se
s rei rei s
es
se
s rei rei s
es
non-reversing
non-reversing
reversing
reversing
300
300 310
310 320
320 330
330 CS
CS 620
620 630
630
SIDE MOUNTED AUXILIARY CONTACTS
Our front mounted auxiliary contacts feature IP20
guarded terminals to protect against accidental
contact with live parts. The device identification
marker simplifies trouble shooting in panels with
many contactors. These contacts snap-on and
install without the use of tools. NOTE: See chart
below for maximum number of front mounted
auxiliary contacts.
Side mounted auxiliary contacts
feature IP20 guarded terminals to
protect against accidental contact with
live parts. NOTE: See chart at left for
maximum number of side mounted
auxiliary contacts.
miniature
miniature
CONTACT CONNECTION
CONFIGURATIONDIAGRAMPRICE
$11.50
-4
14
14
300-SSA02
62
NO NO
2 Normally Open*
300-SSA02X
NO
2 Normally Closed* NO
51
61
84
63
83
64
73
62
$31.00
$31.00
$31.00
71
82
81
52
72
53
74
41
$31.00
*NOTE: For use with 300-SSA11 or 300-SSA20 when more than one side mounted
auxiliary contact module is installed on the same side of the contactor.
INTERLOCKS
Reversing contactor power wiring modules
make field assembly of reversing contactors
easy. Line and load side
over-molded copper bus
bar conductors ensure error
free installation and make
for a rigid assembly with
a mechanical interlock
(300-SMI) or electrial/
mechanical interlock
(300-SMEI).
F
54
61
300-SSA20X
WIRING MODULES
DI S C O U N T
SC H E D U L E
53
54
MAXIMUM NUMBER
4
6
8
FOR USE WITH CONTACTORS
S09, S12, S18, S25
S32, S40
S50, S65, S80
1 Normally Open and
1 Normally Closed*
83
300-SSA11X
71
MAXIMUM NUMBER OF FRONT OR
SIDE MOUNTED AUXILIARY CONTACTS
CODE
300-RWS25
300-RWS40
300-RWS80
22
NO NC
84
$17.00
-6
CONTACTOR
S09, S12, S18, S25
S32, S40
S50, S65, S80, S95, S105
21
72
1 Normally Closed Delayed Break
11
12
-5 NC
$31.00
$17.00
-8
300-SFA01DB
2 Normally Closed
41
-7 NO
24
NO NO
31
1 Normally Open Early Make
22
$31.00
$11.50
-2
300-SFA10EM
21
42
1 Normally Closed
300-SSA20
NO
2 Normally Open NO
13
23
NO NC
13
32
300-SFA01
-1 NC
1 Normally Open and 1 Normally Closed
43
1 Normally Open
300-SSA11
33
300-SFA10
-3 NO
CONTACT CONNECTION
CONFIGURATIONDIAGRAM PRICE
44
CODE
CODE
34
miniature
miniature
se
s rei rei s
es
43
300
300 310
310
se
s rei rei s
es
31
FRONT
MOUNTED
AUXILIARY CONTACTS
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
44
se
s rei rei s
es
32
se
s rei rei s
es
A cc e s s o r i e s /
PRICE
$40.00
$51.00
$97.00
MECHANICAL INTERLOCK
Our side mounted mechanical interlock
for use with reversing contactors, reversing
starters, two-speed starters and star-delta
(wye-delta) starters. This single interlock
can be used with all size contactors from
9A ~ 105A, preventing the forward and
reverse contactors from being energized at
the same time.
ELECTRICAL & MECHANICAL INTERLOCK
c3controls now offers an electrical/mechanical interlock for reversing contactors.
This interlock has the same features as the mechanical interlock but also has two
normally closed auxiliaries built into the unit for electrical interlocking, eliminating
the need for two normally closed auxiliary contacts and the mechanical interlock.
The result of integrating the normally closed auxiliary contact is decreased width of
reversing contactors and more available auxiliary contact locations.
CODEDESCRIPTION
PRICE
300-SMI
300-SMEI
$34.00
$43.00
Side Mounted Mechanical Interlock
Side Mounted Electrical/Mechanical Interlock
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
non-reversing
non-reversing
reversing
reversing
se
s rei rei s
es
se
s rei rei s
es
/A
TB GR
300 310
310
1
1
6
61
1
3
3 DS
DS EC
EC TB
GR
PS
PS 300
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
cc e s s o r i e s
i ei ce c
TB
TB
Contactors
A cc e ss o r i e s f o r N o n - Rseesvrei reeisre ss i n g
and Reversing Contactors
300
300 310
310
The complete range of Series 300 Non-Reversing Contactors andnSeries
Reversing Contactors share common accessoriesminiature
including
single
e
nm
e 310
m
a a
miniature
miniature
miniature
circuit front mounted auxiliary contacts, two circuit side mounted auxiliary contacts, a single electrical/mechanical or mechanical interlock,
and coil mounted surge suppressors. Designing starter assemblies and panels is easy – you don’t have to remember which auxiliary is required
for each contactor, they all work together. Installation is easy too – once you learn how to install each accessory, it’s always the same no matter
se
sisn’t
rei reenough
is
e s – you’ll also reduce your inventory and maximize its flexibility,
what contactor it’s being installed on. If simple design and assembly
because unique accessories are not required for each size contactor.
TB
TB
SURGE SUPPRESSORS
Coil mounted surge suppressors protect sensitive electronic components in control circuits from
damaging line voltage spikes.
DISC OUNT
SC HEDULE
F
RC SURGE SUPPRESSOR
CODE
VOLTAGE RANGE
300-SRCS2J
24 ~ 48V AC
300-SRCS2AH
50 ~ 127V AC
300-SRCS2M
130 ~ 250V AC
300-SRCS5J
24 ~ 48V AC
300-SRCS5AH
50 ~ 127V AC
300-SRCS5M
130 ~ 250V AC
A1
A2
DIODE SURGE SUPPRESSOR
CODE
VOLTAGE RANGE
300-SDS5T
12 ~ 600V DCA1
FOR USE WITH CONTACTOR
S09, S12, S18, S25, S32, S40
S09, S12, S18, S25,
S32, S40
S09, S12, S18, S25,
S32, S40
S50, S65, S80,
S95, S105
S50, S65, S80, S95, S105
S50, S65, S80, S95, S105
PRICE
$29.00
FOR USE WITH CONTACTOR
S09, S12, S18, S25, S32, S40, S50, S65,
S80, S95, S105
PRICE
$29.00
$29.00
$29.00
$29.00
$29.00
$29.00
A2
WE DIDN’T INVENT CONTROL,
WE’RE PERFECTING IT.
42
se
s rei rei s
es
se
s rei rei s
es
non-reversing
non-reversing
reversing
reversing
300
300 310
310 320
320 330
330 CS
CS 620
620 630
630
se
s rei rei s
es
IT’S
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
Replacement Components /
EASY
se
s rei rei s
es
300
300 310
310
TO
BUILD
YOUR
se
s rei rei s
es
OWN
se
s rei rei s
es
OPERATING
COIL
Simply pick the code number from each of the sections below and combine
part number.
themminiature
to
build your
miniature
miniature
miniature
Operating Coils
I II
Example: To build one of our most popular Operating Coils, the part number
would be I + II o r A CS 2 5 D
I. OPERATING COIL TYPE
CODE
ACS25
ACS40
ACS105
DCS25
DCS40
DCS105
DESCRIPTION
AC Operating Coil
AC Operating Coil
AC Operating Coil
DC Operating Coil
DC Operating Coil
DC Operating Coil
FOR USE WITH CONTACTORS
S09, S12, S18, S25
S32, S40
S50, S65, S80, S95, S105
S09, S12, S18, S25
S32, S40
S50, S65, S80, S95, S105
PRICE
$ 26.00
$ 30.00
$ 42.00
$ 53.00
$141.00
$211.00
II. COIL
COIL VOLTAGE
VOLTAGE CODE
CODE
II.
AC COIL
COIL VOLTAGE
VOLTAGE CODES
CODES
AC
12 24
24 48
48 110
110120208220230240277380400
440480500550
550600
VOLTAGE 12
120208220230240277380400400 ~ 415440480500
600
G H
H K
K D
D ——M———QAM
——M——— QAM R S — T
T U
U—
50Hz
G
—
60Hz B
B C
C J
J—D
L—
—F
P—— —
— —
—R——T
60Hz
— D L
——
F P——
R— — T
50/60Hz XB
XBXCXJXD
XCXJXDXAD
XAD—
—XAJ
XNXF——
XAM —
— XQ——
XQ———
——
50/60Hz
XAJXNXF
——XAM
—
DC COIL
COIL VOLTAGE
VOLTAGE CODES
CODES
DC
12
24
24~~28
28
48
42 ~~ 50
50
110
125
110 ~ 130
208 ~~ 240
240 250
VOLTAGE
12
24
24
42
125
130
208
250
ZB
ZK
—
ZQ
—
ZP
-S09 to -S25
ZB
ZC
—
—
ZD
ZQ
—
—
ZP
-S40
ZB
ZC
—
ZK
—
ZD
ZQ
—
—
ZP
-S32 to -S40
—
—
EC—EK—
—
EL EE
—
-S105
—
—
EC
—
EK
—
—
EL
EE
-S50 to -S105
—
—
EC—EK—
—
EL EE
—
CONTACT KITS
One contact kit includes six stationary contacts, three moving contacts and miscellaneous parts.
FOR USE WITH
CODE
CONTACTORSPRICE
300-SCK09
S09
$ 31.00
300-SCK12
S12
$ 44.00
300-SCK18
S18
$ 45.00
300-SCK25
S25
$ 62.00
300-SCK32
S32
$ 74.00
300-SCK40S40
$122.00
300-SCK50S50
$151.00
300-SCK65S65
$176.00
300-SCK80S80
$211.00
300-SCK95S95
$229.00
300-SCK105S105
$281.00
DISC OU NT
SC HEDULE
43
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
F
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
i ei ce c
non-reversing
non-reversing
reversing
reversing
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
/S
TB GR
300 310
310
1
1
6
61
1
3
3 DS
DS EC
EC TB
GR
PS
PS 300
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
pecifications
TB
TB
ELECTRICAL SPECIFICATIONS
Contactors
Specifications:
300
300 310
310
S09 S12S18S25S32S40S50 S65S80S95S105
ne
nm
em
a a
miniature
miniature
miniature
miniature
ELECTRICAL GENERAL
UNITS
Rated Operating Frequency
Hz 25 ~ 400
Impedance per Pole
mΩ 1.90 1.901.601.602.101.60
0.850.86 0.860.76 0.76
se
s rei rei s
es
POWER DISSIPATION PER POLE
AC-1
W 1.47 1.472.463.344.603.426.8910.4010.4014.8914.89
AC-3
W 0.19 0.340.781.031.311.522.12 3.635.506.86 8.37
Rated Coil FrequenciesAC: 50Hz, 60Hz, 50/60Hz and DC
ELECTRICAL UL/CSA APPLICATIONS
Rated Operating Voltage, Ue
VAC
600
General Purpose Current Rating
A
25
25
32
32
60
60
90
110
110
140
140
RATED 1 PHASE OPERATING CURRENT, Ie
115V
A 9.813.81624 3434345680 80100
230V
A 10 121728 2828404050 6088
RATED 1 PHASE OPERATING POWER, Pe
115V
HP1/23/4 1 2 3 3 3 57-1/2
7-1/210
230V
HP
1-1/22 33 55
7-1/2
10151520
RATED 3 PHASE OPERATING CURRENT, Ie
200V
A 11 11 17.525.3 32.232.248.362.162.1 78.2 92
230V
A 9.69.615.222 2842425468 80104
460V
A 7.6111421 2740526565 7796
575V
A 9 111717 2727415262 7777
RATED 3 PHASE OPERATING POWER, Pe
200V
HP 3 3 57-1/21010152020 2530
230V
HP 3 3 57-1/21015152025 3040
460V
HP 57-1/21015 2030 40 50 50 6075
575V
HP
7-1/2101515 2525405060 7575
Size 00—0—1—2——3—
Standard Short Circuit Current
kA
5
5
5
5
5
5
10
10
10
10
10
Maximum Fuse Size
A
30
30
60
60
60
60
100
125
150
175
200
High Fault Short Circuit Current
kA
100
100
100
100
100
100
100
100
100
100
100
Maximum Fuse Size (Class J)
A
25
25
40
40
50
60
90
100
125
150
175
Electrical Endurance, AC-3 at
Maximum Rated 3 Phase
Ops.
1.8
2.0
1.6
1.6
1.5
1.5
1.6
1.8
1.5
1.5
1.0
Operating Power (@460V)
(mill.)
ELECTRICAL IEC APPLICATIONS
Rated Insulation Voltage, Ui
V
1000
Rated Impulse Voltage Withstand, Uimp
kV
6
6
6
6
6
6
8
8
8
8
8
Rated Operating Voltage, Ue
VAC
690
Rated Thermal Current, Ith for Ambient Temperature
A 25253245606090110
110
140140
< 55° C (131° F)
RATED AC-1 OPERATING CURRENT, le
At 55° C (131° F)
A
25
25
32
45
60
60
90
110
110
140
140
At 70° C (158° F)
A
20
20
25
32
48
48
72
88
88
110
110
RATED AC-3 OPERATING CURRENT, le
220 ~ 240V
A 9 12 1825 3240 5065 80 95 105
380 ~ 400V
A 9 12 1825 3240 5065 80 95 105
415 ~ 440V
A 9 12 1825 3240 5065 80 95 105
500V
A 7.510.51419 2432 3855 63 79 85
660 ~ 690V
A 7 9 1315 2225 3444 48 60 80
RATED 3 PHASE AC-3 OPERATING POWER, Pe
220 ~ 240V
kW
2.2
3
4
6.5
9
11
15
18.5
22
25
30
380 ~ 400V
kW
4
5.5
7.5
11
15
18.5
22
30
37
45
55
415 ~ 440V
kW
4
5.5
9
12.5
15
22
30
37
45
55
55
500V
kW5.57.5 101518.525 3040 45 55 65
660 ~ 690V
kW
5.5
7.5
10
15
18.5
30
33
45
45
55
65
TB
TB
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
44
se
s rei rei s
es
se
s rei rei s
es
non-reversing
non-reversing
reversing
reversing
300
300 310
310 320
320 330
330 CS
CS 620
620 630
630
se
s rei rei s
es
se
s rei rei s
es
Specifications /
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
ELECTRICAL AND COIL CHARACTERISTICS SPECIFICATIONS
S09 S12S18S25S32S40S50 S65S80S95S105
se
s rei rei s
es
se
sIEC
rei APPLICATIONS
rei s
es
ELECTRICAL
(CONTINUED)
UNITS
RATED AC-4 OPERATING CURRENT, le
miniature
miniature (Achieves
miniature
miniature
maximum of 200,000 operations)
220 ~ 240V
A 7.5 10.0 15.020.8 26.733.3 41.754.2 66.7 79.2 87.5
380 ~ 400V
A 7.5 10.0 15.020.8 26.733.3 41.754.2 66.7 79.2 87.5
415 ~ 440V
A 7.5 10.0 15.020.8 26.733.3 41.754.2 66.7 79.2 87.5
500V
A 6.3 8.8 11.715.8 20.026.7 31.745.8 52.5 65.8 70.8
660 ~ 690V
A 5.8 7.6 10.812.5 18.320.8 28.336.7 40.0 50.0 66.7
RATED AC-4 OPERATING POWER, Pe
(Achieves maximum of 200,000 operations)
220 ~ 240V
kW1.52.24.05.55.57.511.0
15.0
18.5
22.022.0
380 ~ 400V
kW
3.0
4.0
5.5
7.5
11.0
15.0
22.0
22.0
37.0
37.0
45.0
415 ~ 440V
kW
3.0
4.0
5.5
7.5
11.0
15.0
22.0
22.0
37.0
37.0
45.0
500V
kW 3.0 4.0 5.5 7.5 11.015.0 22.022.0 37.0 37.0 45.0
660 ~ 690V
kW
4.0
5.5
7.5
7.5
15.0
18.5
22.0
30.0
37.0
45.0
55.0
RATED AC-4 OPERATING CURRENT, le
(Achieves maximum of 1,000,000 operations)
220 ~ 240V
A 2.73.65.57.69.712.115.2
19.7
24.2
28.831.8
380 ~ 400V
A 2.73.65.57.69.712.115.2
19.7
24.2
28.831.8
415 ~ 440V
A 2.73.65.57.69.712.115.2
19.7
24.2
28.831.8
500V
A 2.33.24.25.87.39.711.5
16.7
19.1
23.925.8
660 ~ 690V
A 2.12.73.94.56.77.610.3
13.3
14.5
18.224.2
RATED AC-4 OPERATING POWER, Pe
(Achieves maximum of 1,000,000 operations)
220 ~ 240V
kW0.550.751.11.5 2.23.0 4.04.0 5.5 7.5 7.5
380 ~ 400V
kW1.11.52.23.04.05.55.57.511.0
11.015.0
415 ~ 440V
kW1.11.52.23.04.05.55.57.511.0
11.015.0
500V
kW1.11.52.23.04.05.55.57.511.0
11.015.0
660 ~ 690V
kW1.51.53.03.05.55.57.511.0
11.0
15.022.0
RATED SHORT-TIME CURRENT, lcw
1 Second
A
455
455
570
630
1010
1265
1580
2530
2530
3300
3300
5 Seconds
A
205
205
254
280
450
450
710
1130
1130
1485
1485
10 Seconds
A
144
144
180
200
320
400
500
800
800
1050
1050
30 Seconds
A
85
85
104
115
185
230
290
460
460
600
600
1 Minute
A
60
60
74
80
130
165
205
325
325
430
430
3 Minutes
A
35
35
46
50
90
100
120
185
185
250
250
Short Circuit Protection
with Fuses (gG/gL) Ue ≤ 690V
Type 1
A
50
50
63
63
100
125
200
200
200
250
250
Type 2
A
25
35
35
50
63
80
100
125
125
160
200
MAXIMUM ELECTRICAL SWITCHING RATE
AC-1
Ops./hr. 1200
1200
1200
1200
1200
1200
1200
1200
1200
600
600
AC-3
Ops./hr. 1200
1200
1200
1200
1200
1200
1200
1200
1200
600
600
AC-4
Ops./hr.
360
360
360
360
360
200
200
200
200
200
200
Electrical Endurance, AC-3 at Maximum Rated 3 Phase
Ops.
1.6
1.8
1.3
1.4
1.3
1.3
1.2
1.4
1.2
1.2
1.0
Operating Power (@400V)
(mill.)
Making Capacity
A
450
450
450
450
550
550
1000
1000
1000
1280
1280
BREAKING CAPACITY
Ue ≤ 400V
A
250
250
250
250
450
450
920
920
920
1050
1050
Ue = 500V
A
250
250
250
250
450
450
920
920
920
1050
1050
Ue = 690V
A
130
130
130
130
170
205
780
780
780
950
950
COIL CHARACTERISTICS
Rated Insulation Voltage, Ui
V 1000
OPERATING LIMITS 50HZ, 60HZ, 50/60HZ
Operating
xUc
0.80 ~ 1.10
Pick-Up
xUc
0.60 ~ 0.60 ~ 0.60 ~ 0.60 ~ 0.60 ~ 0.60 ~ 0.65 ~ 0.65 ~ 0.65 ~ 0.65 ~ 0.65 ~
0.80 0.800.800.800.800.800.800.800.800.80 0.80
Drop-Out
xUc
0.35 ~ 0.35 ~ 0.35 ~ 0.35 ~ 0.40 ~ 0.40 ~ 0.40 ~ 0.40 ~ 0.40 ~ 0.40 ~ 0.40 ~
0.55 0.550.550.550.600.60 0.600.600.600.60 0.60
300
300 310
310
45
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
non-reversing
non-reversing
reversing
reversing
/S
TB GR
300 310
310
1
1
6
61
1
3
3 DS
DS EC
EC TB
GR
PS
PS 300
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
pecifications
i ei ce c
Contactors
MECHANICAL, ENVIRONMENTAL AND CONSTRUCTION SPECIFICATIONS
S09
S12
S18
S25
S32
S40
S50
S65
S80
S95
S105
COIL CHARACTERISTICS (CONTINUED)
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
DC
Operating
xUc 0.80 ~ 1.10
ne
n0.45
m
em
a
miniature
miniature
Pick-Up
xUc
0.45 ~ 0.45 ~
~ a 0.45 ~ 0.45 ~ 0.45 ~ 0.70 ~ 0.70 ~ 0.70
~miniature
0.70 ~ 0.70 ~miniature
0.65 0.650.650.650.750.750.80 0.800.800.80 0.80
Drop-Out
xUc
0.15 ~ 0.15 ~ 0.15 ~ 0.15 ~ 0.15 ~ 0.15 ~ 0.40 ~ 0.40 ~ 0.40 ~ 0.40 ~ 0.40 ~
0.30 0.300.300.300.300.300.60
0.600.600.60 0.60
se
s rei rei s
es
COIL CONSUMPTION
50HZ, 60HZ, 50/60HZ
Pick-Up
VA
50 ~ 70 50 ~ 70 50 ~ 70 50 ~ 70 70 ~ 90 70 ~ 90 250 ~ 275 250 ~ 275250 ~ 275 250 ~ 275 250 ~ 275
Hold-In
VA
7 ~ 11 7 ~ 11 7 ~ 11 7 ~ 11 9 ~ 13 9 ~ 13 16 ~ 20 16 ~ 20 16 ~ 20 16 ~ 20 16 ~ 20
DC
Pick-Up
W
5 ~ 9
5 ~ 9
5 ~ 9
5 ~ 9 7 ~ 10 7 ~ 10
340
340
340
340
340
Hold-In
W
5 ~ 9
5 ~ 9
5 ~ 9
5 ~ 9 7 ~ 10 7 ~ 10
6.5
6.5
6.5
6.5
6.5
OPERATING TIMES
AC
Pick-Up
msec.
8 ~ 20 8 ~ 20 8 ~ 20 8 ~ 20 10 ~ 19 10 ~ 19 15 ~ 30 15 ~ 30 15 ~ 30 15 ~ 30 15 ~ 30
Drop-Out
msec.
6 ~ 13 6 ~ 13 6 ~ 13 6 ~ 13 5 ~ 25 5 ~ 25 9 ~ 15 9 ~ 15 9 ~ 15 9 ~ 15 9 ~ 15
DC
Pick-Up
msec.
35 ~ 45 35 ~ 45 35 ~ 45 35 ~ 45 40 ~ 55 40 ~ 55 50 ~ 60 50 ~ 60 50 ~ 60 50 ~ 60 50 ~ 60
Drop-Out
msec.
7 ~ 12 7 ~ 12 7 ~ 12 7 ~ 12 30 ~ 65 30 ~ 65 55 ~ 60 55 ~ 60 55 ~ 60 55 ~ 60 55 ~ 60
POWER DISSIPATION
50Hz, 60Hz, 50/60Hz
W 2.6 2.62.62.64.34.3 8.08.08.08.0 8.0
POWER FACTOR
Closedcosϕ 0.33 0.330.330.330.28 0.280.260.260.260.26 0.26
Opencosϕ 0.84 0.840.840.840.73 0.730.540.540.540.54 0.54
MECHANICAL
UNITS
Mechanical Endurance
Ops. 10
(mill.)
Maximum Mechanical Ops./
9,000
Switching Rate
hr.
ENVIRONMENTAL
Ambient Operating Temperature
°C / °F
-25 to +55 / -13 to +131
Ambient Storage Temperature
°C / °F
-55 to +80 / -58 to +176
Altitude
m / ft.
3,000 / 9,792
CONSTRUCTION GENERAL
Pollution Degree
3 333333333 3
INGRESS PROTECTION
Main Terminals
IP20 IP20 IP20 IP20*IP20*IP20*IP20*IP20*IP20*IP20* IP20*
Coil Terminals
IP20 IP20IP20IP20IP20IP20IP20IP20IP20IP20 IP20
Auxiliary Contact Terminals
IP20 IP20IP20IP20IP20IP20IP20IP20IP20IP20 IP20
Weight
kg 0.2950.2950.2950.2950.52 0.541.1051.12 1.13 1.45 1.47
lbs.
0.65
0.65
0.65
0.65
1.15
1.19
2.44
2.47
2.49
3.20
3.24
TB
TB
300
300 310
310
TB
TB
*NOTE: With conductors connected.
For RoHS compliance documentation by product, refer to www.c3controls.com.
ROHS COMPLIANCE S09 - S25
S32 - S40
S50 - S80
S95 - S105
CONSTRUCTION CONDUCTOR
CROSS-SECTIONS, MAIN TERMINALS
UNITS
MAIN TERMINAL CAPACITY
Solid Stranded and Finely
mm2
2 x 0.5 ~ 6
2 x 1 ~ 14
2 x 1 ~ 34
2 x 1 ~ 43
Stranded without End Sleeve
AWG Wire
AWG
2 x 20 ~ 10
2 x 18 ~ 6
2 x 16 ~ 2
2 x 16 ~ 1
Recommended Strip Length
mm
8.5
10
13
15
in
5/16
3/8
1/2
9/16
Tightening Torque
Lb-in.
8.8 ~ 16.9
22.1 ~ 26.6
35.4 ~ 53.1
44.3 ~ 57.5
Nm
1.0 ~ 1.9
2.5 ~ 3.0
4.0 ~ 6.0
5.0 ~ 6.5
Screwdriver
Phillips nr. 2
Phillips nr. 2
Allen 4mm
Allen 4mm
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
46
se
s rei rei s
es
se
s rei rei s
es
non-reversing
non-reversing
reversing
reversing
se
s rei rei s
es
se
s rei rei s
es
300
300 310
310 320
320 330
330 CS
CS 620
620 630
630
300
300 310
310
se
s rei rei s
es
se
s rei rei s
es
Specifications /
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
AUXILIARY CONTACTS SPECIFICATIONS
INTERNAL AUXILIARY CONTACT
CONTACT BLOCKS
S09-S25
300-SFA & 300-SSA
ELECTRICAL
GENERAL
miniature
miniature
miniature
miniature
UNITS
Minimum Switching Capacity
5mA @ 17V
Electrical Endurance
Ops. (mill.)
1
Mechanical Endurance
Ops. (mill.)
15
Non-Overlap Time
msec.
1.5
Insulation Resistance
MΩ
>10
ELECTRICAL UL/CSA APPLICATIONS
Rated Operating Voltage, Ue
V
600
PILOT DUTY RATING
AC
A600
DC
P600
Q600
ELECTRICAL IEC APPLICATIONS
Rated Insulation Voltage, Ui
V
1000
Rated Operating Voltage, Ue
V
690
Rated Thermal Current, Ith for A
20
10
Ambient Temperature <55° C
RATED AC-15 OPERATING CURRENT, le
110 ~ 120V
A
10
6
220 ~ 240V
A
10
6
380 ~ 400V
A
6
4
415 ~ 450V
A
5
3.5
500V
A
4
2.5
600 ~ 690V
A
2
1.5
RATED DC-13 OPERATING CURRENT, Ie
24V
A
6
6
48V
A
4
4
110V
A
2
2
220V
A
0.7
0.7
440V
A
0.7
0.3
MAKING CAPACITY, Im
AC-15/AC-11 Ue ≤ 400V A
250
90
50/60Hz
DC-13/DC-11 Ue ≤ 220V
A
250
90
BREAKING CAPACITY, Im
AC-15/AC-11 Ue ≤ 400V A
250
60
50/60Hz
DC-13/DC-11 Ue ≤ 220V
A
2
0.95
Short Circuit Protection A
10
10
with Fuses (gG/gL)
For RoHS compliance documentation by product, refer to www.c3controls.com.
ROHS COMPLIANCE OPERATING POSITIONS
30°
30°
47
30°
30°
30°
30°
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
non-reversing
non-reversing
reversing
reversing
C
TB/ GR
300 310
310
1
1
6
61
1
3
3 DS
DS EC
EC TB
GRDPS
PS 300
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
se
s rei rei s
es
ircuit
iagrams
i ei ce c
Contactors
S E R I E S 3 0 0 N O N - R E V E R S IsNesG
Ce O
N T A C T O R C I R C U I T Ds IesAreiG
R
AMS
rei rei s
s
rei s
es
se
s rei rei s
es
TB
TB
ne
nm
em
a a
POWER CIRCUIT
300
300 310
310
miniature
miniature
CONTROL CIRCUIT
miniature
miniature
se
s rei rei s
es
TB
TB
M1
F
M2
R
= Forward Contactor
= Forward Push Button
= Reverse Contactor
= Reverse Push Button
= Start Push Button
= Emergency Stop Push Button
= Coil Voltage Code
SERIES 310 REVERSING CONTACTOR CIRCUIT DIAGRAMS
CONTROL CIRCUIT
POWER CIRCUIT
11
12
L1
L2
L3
CONTROL CIRCUIT
CONTROL CIRCUIT
POWER CIRCUIT
POWER CIRCUIT
13
13
R
F
14
1L1
3L2
5L3
1L1
3L2
M1
13
4T2
6T3
2T1
4T2
14
V
14
W
01
01
02
02
M1
A1
A1
A2
A2
M2
M1
M
3
13
6T3
M2
U
M2
5L3
M2
2T1
14
M1 = Forward Contactor
F = Forward Push Button
= Reverse
Contactor
M1M2
= Forward
Contactor
F
= Reverse
Push
Button
M1R = Forward
Contactor
Push
Button
Contactor
M2
F = Reverse
Forward
Push
Button
= Emergency
Stop
Push Button
Contactor
Push
Button
R
M2 = Reverse
= Coil Voltage
Code
Push
Button
Reverse
Push
Button
R = Start
= Emergency
Stop Push Button
Start Push Button
Emergency
= Coil
VoltageStop
CodePush Button
= Coil Voltage Code
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
48
se
s rei rei s
es
se
s rei rei s
es
non-reversing
non-reversing
reversing
reversing
se
s rei rei s
es
se
s rei rei s
es
miniature
miniature
miniature
miniature
300
300 310
310 320
320 330
330 CS
CS 620
620 630
630
se
s rei rei s
es
UTILIZATION
1. Identify the utilization category of the application.
3**-S09
To find a contactor’s estimated life:
10
se
s rei rei s
es
CATEGORY
3**-S32
3**-S40
3**-S50
3**-S65
3**-S80
3**-S95
3**-S105
IN
3**-S25
LIFE
se
s rei rei s
es
3**-S18
ELECTRICAL
300
300 310
310
se
s rei rei s
es
3**-S12
se
s rei rei s
es
Electrical Life /
AC-1
10
25 32 45 60 90 110 140
100
Breaking Current Ie (A)
3**-S65
3**-S80
3**-S95
3**-S105
1
3**-S40
3**-S50
0.1
3**-S32
The life-load curves are based on tests in accordance
with IEC 60947-4-1. Many conditions of an
actual application effect contact life such as the
environment and duty cycle. Therefore, the actual
contact life may vary from the life indicated by the
curves shown here.
3**-S12
3**-S18
3**-S25
4.Read the estimated contactor life from the vertical
axis of the chart.
1
3**-S09
3.Locate the intersection of the life-load curve
for the contactor selected with the application
breaking current (Ie) on the horizontal axis of
the chart.
Electrical Life (106)
2.Refer to the chart for the applicable utilization
category.
AC-3
10
Electrical Life (106)
NOTE: ** Represents the Non-Reversing or Reversing
Contactor Code. Refer to pages 35 & 37.
1
0.1
18
25 32 40 50 65 8095105
Breaking Current le (A)
3**-S65
3**-S80
3**-S95
3**-S105
12
3**-S40
3**-S50
3**-S32
3**-S12
3**-S18
3**-S25
3**-S09
9
AC-4
Electrical Life (106)
10
1
0.1
49
30 42 48
72 96 138 222 300 500
110 180 264 400 600
Breaking Current le (A)
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
series
63mm
s e r i e(2-31/64”)
s
series
series
114mm
s(4-31/64”)
eries
85mm
(3-11/32”)
non-reversing
/D
22 16 13 DS EC TB GR
PS 300
series
series
series
series
iec
iec
22
3
P O LE
N ON - R E V E RS ING
-
TB
A C
C O I L Sseries
300
300-S09, 300-S12, 300-S18 & 300-S25
nema
93mm
3-85/128”)
75mm
(2-61/64”)
C ON
T A C T 81mm
OR S
s e r i e s (3-3/16”)
Contactors
series
45mm
imensions
(1-99/128”)
9mm
(23/64”)
114mm
114mm
(4-31/64”)
(4-31/64”)
85mm
85mm
(3-11/32”)
(3-11/32”)
63mm
63mm
(2-31/64”)
(2-31/64”)
45mm
45mm
(1-99/128”)
(1-99/128”)
9mm
9mm
(23/64”)
(23/64”)
nema
miniature
35mm
(1-3/8”)
series
TB
9mm
(23/64”)
73mm
127mm
(5”)
98mm
(3-55/64”)
(2-7/8”)
4.7mm
55mm
(3/16”)
(2-21/128”)
72.5mm
(2-109/128”)
81mm
81mm
(3-3/16”)
(3-3/16”)
87mm
(3-27/64”)
35mm
35mm
(1-3/8”)
(1-3/8”)
4.5mm
(23/128”)
10mm
(25/64”)
300-S32 & 300-S40
73mm
73mm
(2-7/8”)
(2-7/8”)
9mm
55mm
9mm 4.7mm 55mm
4.7mm(2-21/128”)
(23/64”)(3/16”)
(2-21/128”)
(23/64”)
89mm
(3-65/128”)
127mm
127mm
(5”)(5”)
98mm
98mm
(3-55/64”)
(3-55/64”)
(3/16”)
72.5mm
72.5mm
(2-109/128”)
(2-109/128”)
9mm
(23/64”)
45mm
84mm
(1-99/128”)
(3-5/16”)
16.5mm
(83/128”)
87mm
87mm
(3-27/64”)
(3-27/64”)
4.5mm
4.5mm
(23/128”)
(23/128”)
10mm
10mm
(25/64”)
(25/64”)
84mm
(3-5/16”)
16.5mm
16.5mm
9mm
(83/128”)
66mm
(83/128”)
(23/64”)
(2-77/128”)
12.5mm
12.5mm
(63/128”)
(63/128”)
112mm
(4-13/32”)
78mm
(3-5/64”)
116.5mm
(4-75/128”)
112mm
12.5mm
(4-13/32”)
(63/128”)
89mm
89mm
(3-65/128”)
(3-65/128”)
45mm
45mm
(1-99/128”)
(1-99/128”)
4.5mm
(23/128”)
300-S50, 300-S65 & 300-S80
78mm
78mm
(3-5/64”)
(3-5/64”)
144mm
(5-43/64”)
115mm
(4-17/32”)
66mm
(2-77/128”)
70mm
(2-97/128”)
58mm
(2-37/128”)
56mm
(2-13/64”)
144mm
(5-43/64”)
115mm
(4-17/32”)
4.5mm
4.5mm
116.5mm
(23/128”)
(23/128”)
(4-75/128”)
90mm
(3-35/64”)
5.5mm
(7/32”)
6mm
(15/64”)
7.5mm
(19/64”)
9mm
(23/64”)
70mm
(2-97/128”)
93mm
58mm
(3-85/128”)
(2-37/128”)
75mm
56mm
(2-61/64”)
(2-13/64”)
70mm
(2-97/128”)
58mm
(2-37/128”)
56mm
(2-13/64”)
300-S9570mm
& 300-S105
(2-97/128”)
58mm
(2-37/128”) 155mm
(6-13/128”)
93mm
56mm
126mm
(3-85/128”)
(2-13/64”)
9mm (4-123/128”)
75mm
(23/64”)
(2-61/64”)
90mm
(3-35/64”)
90mm
(3-35/64”)
114.5mm
(4-65/128”)
7.5mm
(19/64”)
5.5mm
(7/32”)
7.5mm
5.5mm
(19/64”)
(7/32”)
6mm
(15/64”)
90mm
6mm
(3-35/64”)
(15/64”)
122mm
(4-103/128”) 114.5mm
5.5mm
(4-65/128”)
(7/32”)
7.5mm
(19/64”)
6mm
(15/64”)
70mm
155mm
(2-97/128”)
(6-13/128”)
58mm
126mm
(2-37/128”)
(4-123/128”)
56mm
(2-13/64”)
122mm
90mm
(4-103/128”) (3-35/64”)
5.5mm
(7/32”)
6mm
(15/64”)
122mm
(4-103/128”)
7.5mm
(19/64”)
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING
IT.
50
”)
series
series
63mm
300 310 320 330 CS 620 630
Dimensions /
3
series
45mm
(1-99/128”)
s35mm
eries
series
(1-3/8”)
4.5mm
(23/128”)
4.7mm
(3/16”)
72.5mm
(2-109/128”)
81mm
(3-3/16”)
Ps O
LE N ON - R E V E R S ING
eries
300 310
miniature
9mm
(23/64”)
reversing
non-reversing
series
s e r(2-31/64”)
ies
series
C ONTA C TOR S
D C
C OI L S
10mm
300-S09, 300-S12, 300-S18
& 300-S25
(25/64”)
miniature
63mm
(2-31/64”)
9mm
(23/64”)
45mm
(1-99/128”)
4.7mm
(3/16”)
35mm 144mm
63mm
(1-3/8”) (5-43/64”)
(2-31/64”)
115mm 4.5mm
9mm
45mm
(4-17/32”)
(23/64”)(23/128”)(1-99/128”)
35mm
(1-3/8”)
72.5mm
(2-109/128”)
81mm
(3-3/16”)
10mm
(25/64”)
144mm
(5-43/64”)
115mm
(4-17/32”)
73mm
73mm
(2-7/8”)
(2-7/8”)
73mm
55mm
(2-7/8”)
55mm
(2-21/128”)
(2-21/128”)
55mm
(2-21/128”)
10mm
(25/64”)
300-S32 & 300-S40
163mm
163mm
(6-27/64”)
(6-27/64”)
134mm163mm
134mm
(5-9/32”)
(6-27/64”)
(5-9/32”)
134mm
(5-9/32”)
144mm
45mm
(5-43/64”)
45mm
(1-99/128”)
115mm
(1-99/128”)
(4-17/32”)
45mm
16.5mm
16.5mm
(83/128”) 84mm
(83/128”)
(3-5/16”)
16.5mm
9mm (83/128”)
66mm
(23/64”)
87mm
87mm
(3-27/64”)
(3-27/64”)
87mm
(3-27/64”)
4.5mm
(23/128”)
4.7mm
(3/16”)
72.5mm
(2-109/128”)
81mm
(3-3/16”)
9mm
9mm
(23/64”)
(23/64”)
9mm
(23/64”)
-
89mm
89mm
(3-65/128”)
(3-65/128”)
89mm
(3-65/128”)
(1-99/128”)
78mm
78mm
(3-5/64”)
(3-5/64”)
78mm
(3-5/64”)
(2-77/128”)
12.5mm
12.5mm
(63/128”)
(63/128”)
112mm 12.5mm
(4-13/32”)(63/128”)
144mm
(5-43/64”)
115mm
(4-17/32”)
116.5mm
4.5mm
4.5mm
(23/128”)
(4-75/128”)
(23/128”)
4.5mm
(23/128”)
300-S50, 300-S65 & 300-S80
9mm
(23/64”)
84mm
(3-5/16”)
66mm
(2-77/128”)
70mm
(2-97/128”)
58mm
(2-37/128”)
56mm
(2-13/64”)
144mm
(5-43/64”)
115mm
(4-17/32”)
116.5mm
(4-75/128”)
112mm
(4-13/32”)
90mm
(3-35/64”)
5.5mm
(7/32”)
6mm
(15/64”)
7.5mm
(19/64”)
93mm
(3-85/128”)
75mm
(2-61/64”)
70mm
(2-97/128”)
58mm
(2-37/128”)
56mm
70mm(2-13/64”)
(2-97/128”)
58mm
93mm
(2-37/128”)
(3-85/128”)
9mm
56mm
75mm
(23/64”) 90mm(2-13/64”)
(2-61/64”)
(3-35/64”)
5.5mm
(7/32”)
90mm 7.5mm
(3-35/64”)
114.5mm (19/64”)
(4-65/128”)
5.5mm
(7/32”)
m
8”)
7.5mm
(19/64”)
51
300-S95 & 300-S105
70mm
(2-97/128”)
58mm 155mm
(2-37/128”)
(6-13/128”)
93mm
56mm
126mm
(2-13/64”) (3-85/128”)
9mm (4-123/128”)
75mm
(23/64”)
(2-61/64”)
70mm
155mm
(2-97/128”)
(6-13/128”)
58mm
126mm
(2-37/128”)
(4-123/128”)
56mm
(2-13/64”)
(4-
6mm
(15/64”)
6mm
(15/64”)
90mm
(3-35/64”)
122mm
(4-103/128”)
114.5mm
5.5mm
(4-65/128”)
(7/32”)
7.5mm
(19/64”)
6mm
(15/64”)
122mm
90mm
(4-103/128”)(3-35/64”)
5.5mm
(7/32”)
7.5mm
(19/64”)
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
6mm
(15/64”)
122mm
(4-103/128”)
series
series
114mm
i m e n s i(4-31/64”)
ons
85mm
non-reversing
(3-11/32”)
series
/D
300 310
16 13 DS EC TB GR PS
series
series
series
series
s e r i e s 99mm s e r i e s
(3-115/128”)
9mm
45mm
(23/64”)
(1-99/128”)
iec
reversing
Contactors
81mm
3 P O L E C O N T A C T O R S (3-3/16”)
W
ITH ELECTRICAL/
ries
eries
series
M E C H A N I C A L O R M E C H sAe N
I C A L I N T E R L O C K - As C
COILS
TB
300 310
310-S09, 310-S12,
n e m a310-S18 & 310-S25
99mm
(3-115/128”)
9mm
45mm
(23/64”)
(1-99/128”)
114mm
(4-31/64”)
series
85mm
(3-11/32”)
miniature
18mm
(91/128”)
4.7mm
(3/16”)
TB
35mm
(1-3/8”)
119mm
(4-11/16”)
9mm
55mm
(23/64”)
(2-21/128”)
72.5mm
(2-109/128”)
81mm
(3-3/16”)
87mm
(3-27/64”)
4.7mm
(3/16”)
35mm
(1-3/8”)
119mm
(4-11/16”)
9mm
55mm
(23/64”)
(2-21/128”)
87mm
(3-27/64”)
16.5mm
(83/128”)
4.5mm
(23/128”)
19mm
(3/4”)
45mm
45mm
(1-99/128”)
141mm (1-99/128”)
(5-71/128”)
9mm
66mm
(23/64”)
(2-77/128”)
4.5mm
(23/128”)
19mm
(3/4”)
310-S50, 310-S65 & 310-S80
4.5mm
(23/128”)
70mm
(2-97/128”)
58mm
(2-37/128”)
56mm
(2-13/64”)
144mm
(5-43/64”)
144mm
(5-43/64”)
115mm
(4-17/32”)
115mm
(4-17/32”)
116.5mm
(4-75/128”)
116.5mm
(4-75/128”)
90mm
(3-35/64”)
6mm
5.5mm (15/64”)
(7/32”)
7.5mm
(19/64”)
70mm
(2-97/128”)
70mm
(2-97/128”)
58mm
(2-37/128”)
58mm
(2-37/128”)
56mm
(2-13/64”)
56mm
159mm
(2-13/64”)
114.5mm
(4-65/128”)
114.5mm
114.5mm
(4-65/128”)
(4-65/128”)
17mm
(43/64”)
310-S95 & 310-S105
70mm
(2-97/128”)
70mm
70mm
(2-97/128”)
(2-97/128”)
58mm
(2-37/128”)
58mm
58mm
56mm
(2-37/128”)
(2-37/128”)
(2-13/64”)
56mm
56mm
(2-13/64”)
(2-13/64”)
155mm
(6-13/128”)
155mm
155mm
(6-13/128”)
(6-13/128”)
126mm
(4-123/128”)
126mm
126mm
(4-123/128”)
(4-123/128”)
(6-17/64”)
159mm
159mm
(6-17/64”) 9mm
75mm(6-17/64”)
(23/64”)
9mm
9mm
(2-61/64”)
75mm
75mm
(23/64”)
(23/64”)
(2-61/64”)
(2-61/64”)
90mm
(3-35/64”)
90mm
6mm
(3-35/64”)
6mm
5.5mm (15/64”)
(7/32”)
5.5mm (15/64”)
(7/32”)
7.5mm
(19/64”)
7.5mm
(19/64”)
144mm
(5-43/64”)
115mm
(4-17/32”)
116.5mm
(4-75/128”)
112mm
(4-13/32”)
12.5mm
(63/128”)
45mm
45mm
(1-99/128”)
(1-99/128”)
141mm
(5-71/128”)
141mm
(5-71/128”)
9mm
66mm
(23/64”)
(2-77/128”)
9mm
66mm
78mm (2-77/128”)
(23/64”)
(3-5/64”)
112mm
12.5mm
(4-13/32”)
112mm
(63/128”)
(4-13/32”)
16.5mm
(83/128”)
78mm
(3-5/64”)
89mm
(3-65/128”)
10mm
(25/64”)
4.5mm
(23/128”)
310-S32 & 310-S40
127mm
(5”)
98mm
(3-55/64”)
72.5mm
(2-109/128”)
127mm
(5”)
98mm
(3-55/64”)
89mm
(3-65/128”)
10mm
(25/64”)
18mm
(91/128”)
35mm
(1-3/8”)
35mm
(1-3/8”)
miniature
122mm
(4-103/128”)
122mm
122mm
(4-103/128”)
(4-103/128”)
17mm
(43/64”)
17mm
(43/64”)
90mm
(3-35/64”)
90mm
90mm
(3-35/64”)
(3-35/64”)
7.5mm
(19/64”)
7.5mm
7.5mm
(19/64”)
(19/64”)
6mm
(15/64”)
6mm
6mm
5.5mm
(15/64”)
(15/64”)
(7/32”)
5.5mm
5.5mm
(7/32”)
(7/32”)
26mm
(1-1/32”)
26mm
26mm
(1-1/32”)
(1-1/32”)
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.
52
series
310 320 330 CS 620 630
series
series
series
Dimensions /
s e r i e s99mm
(3-115/128”)
series
3
series
310
9mm
(23/64”)
45mm
(1-99/128”)
reversing
144mm
(5-43/64”)
115mm
(4-17/32”)
81mm
P O L E C O N T A C T O R S W I T H E L E C (3-3/16”)
TRICAL/MECHANICAL
OR MECHANICAL INTERLOCK - DC COILS
310-S09, 310-S12, 310-S18 & 310-S25
miniature
99mm
(3-115/128”)
45mm
(1-99/128”)
18mm
(91/128”)
144mm
(5-43/64”)
9mm
(23/64”)
4.7mm
(3/16”)
115mm
(4-17/32”)
35mm
(1-3/8”)
35mm
(1-3/8”)
119mm
(4-11/16”)
87mm
10mm
(3-27/64”)
(25/64”)
18mm
(91/128”)
4.7mm
(3/16”)
35mm
(1-3/8”)
35mm
(1-3/8”)
87mm
(3-27/64”)
10mm
(25/64”)
112mm
(4-13/32”)
78mm
(3-5/64”)
45mm
(1-99/128”)
112mm
12.5mm
(4-13/32”)
112mm
(63/128”)
(4-13/32”)
4.5mm
(23/128”)
12.5mm
(63/128”)
310-S50, 310-S65 & 310-S80
45mm
(1-99/128”)
144mm
(5-43/64”)
115mm
(4-17/32”)
116.5mm
(4-75/128”)
116.5mm
(4-75/128”)
4.5mm116.5mm
(4-75/128”)
(23/128”)
70mm
(2-97/128”)
58mm
(2-37/128”)
56mm
(2-13/64”)
144mm
(5-43/64”)
144mm
(5-43/64”)
115mm
(4-17/32”)
115mm
(4-17/32”)
141mm
(5-71/128”)
141mm
9mm
66mm (5-71/128”)
(23/64”)
(2-77/128”)
9mm
66mm
(23/64”)
(2-77/128”)
45mm
(1-99/128”)
141mm
(5-71/128”)
9mm
(23/64”)
89mm
(3-65/128”)
4.5mm
(23/128”)
45mm
(1-99/128”)
16.5mm
(83/128”)
78mm
66mm
(3-5/64”)
(2-77/128”)
19mm
(3/4”)
16.5mm
(83/128”)
90mm
(3-35/64”)
6mm
5.5mm (15/64”)
(7/32”)
7.5mm
(19/64”)
114.5mm
(4-65/128”)
114.5mm
(4-65/128”)
70mm
(2-97/128”)
70mm
58mm
(2-97/128”)
(2-37/128”)
58mm
(2-37/128”)
56mm
(2-13/64”)
56mm
(2-13/64”)
159mm
(6-17/64”)
159mm
75mm(6-17/64”) 9mm
(23/64”)
90mm
(2-61/64”)
9mm
75mm
(3-35/64”)
90mm (23/64”)
(2-61/64”)
6mm
(3-35/64”)
5.5mm (15/64”)
6mm
(7/32”)
5.5mm (15/64”)
(7/32”)
7.5mm
(19/64”)
7.5mm
(19/64”)
89mm
(3-65/128”)
19mm
(3/4”)
147mm
(5-101/128”)
118mm
(4-83/128”)
9mm
(23/64”)
55mm
72.5mm
(2-21/128”)
(2-109/128”)
4.5mm
(23/128”)
310-S32 & 310-S40
119mm
(4-11/16”)
147mm
(5-101/128”)
118mm
(4-83/128”)
9mm
(23/64”)
55mm
72.5mm
(2-109/128”) (2-21/128”)
81mm
(3-3/16”)
310-S95 & 310-S105
155mm
70mm
(2-97/128”)
70mm
(2-97/128”)
58mm
(2-37/128”)
58mm
56mm
(2-37/128”)
(2-13/64”)
56mm
(2-13/64”)
(6-13/128”)
155mm
126mm
(6-13/128”)
(4-123/128”)
126mm
(4-123/128”)
122mm
17mm
(43/64”)
122mm
17mm(4-103/128”)
(4-103/128”)
(43/64”)
17mm
(43/64”)
90mm
(3-35/64”)
90mm
(3-35/64”)
7.5mm
(19/64”)
7.5mm
(19/64”)
6mm
(15/64”)
6mm
5.5mm
(15/64”)
(7/32”)
5.5mm
(7/32”)
26mm
(1-1/32”)
26mm
(1-1/32”)
VI SI T WWW.C 3 C ONT R O L S.CO M
TO DOWNLOAD C AD DR A W I N G S
53
WE DIDN’T INVENT CONTROL, WE’RE PERFECTING IT.

Similar documents

Cataloque 2 (Accessorie)

Cataloque 2 (Accessorie) PEDAL PAD SETS & GEAR LEVER KNOBS PRACTICAL, QUALITY ACCESSORIES PEDAL PAD SETS - ALUMINIUM BODY

More information