CKD Pneumatic Valves
Transcription
CKD Pneumatic Valves
Discrete valve Body porting 3GA1·2·3 /4GA1·2·3 Series • Applicable cylinder bore size: 20 to 100 mm Common specifications CAD DATA AVAILABLE. Electrical specifications Descriptions Descriptions Working fluid Compressed air Valve and solenoid type Min. working pressure Rated voltage MPa Max. working pressure MPa 0.7 Holding current Withstanding pressure 1.05 Note 3 Ambient temperature °C -5 to 55 Fluid temperature °C -5 to 55 Manual override DC24V 0.023 (0.025) A DC12V 0.046 (0.050) Power consumption DC24V 0.55 (0.6) W DC12V 0.55 (0.6) Note 3 Apparent power VA AC100V Main valve/pilot valve common exhaust type Lubrication Note 1 Not required Heat proof class Protection structure Note 2 Dust proof Temperature rise 50 or less/300 or less Surge suppressor m/s2 Vibration/impact Working environment 0.010 (0.012) AC100V Non-locking/locking type Pilot exhaust method 100 ±10% Rated voltage fluctuation 0.2 (2-position, 3-position) MPa 12, 24 DC V AC Pilot operated soft spool valve 1.0 (1.2) B °C 50 Option Indicator Not to be subject to corrosive gas Note 1. For lubrication, please use turbine oil Class 1ISOVG32. Too much lubrication and intermittent lubrication may cause unstable operation. Note 2. Not to be subject to water drip, oil etc. For DIN terminal box specifications, IP65 (jet-proof type). Cable O.D. and tightening torque conformable with the regulations should be observed. Reference. Pressure unit is Mpa. Conversion ratio is 1MPa=10.1972kgf/cm2. Indicator light (Option) Note 3. The value in ( ) for indicator light. Individual specifications Descriptions Port size 3GA1 Port P/R1/R2 3GA3 4GA1 4GA2 4GA3 M5 Rc1/8 Rc1/4 M5 Rc1/8 Rc1/4 M5 Rc1/8 Rc1/4 M5 Rc1/8 Rc1/4 3GA1 3GA2 3GA3 4GA1 4GA2 4GA3 P → A/B A/B → R1/R2 P → A/B A/B → R1/R2 P → A/B A/B → R1/R2 P → A/B A/B → R1/R2 P → A/B A/B → R1/R2 P → A/B A/B → R1/R2 Descriptions Port size Port A/B Effective 3GA2 Push in joint 4, 6 dia. Push in joint 4, 6, 8 dia. Push in joint 6, 8, 10 dia. Push in joint 4, 6 dia. Push in joint 4, 6, 8 dia. Push in joint 6, 8, 10 dia. Port A/B Push in joint 6 dia. Push in joint 8 dia. Push in joint 10 dia. Push in joint 6 dia. Push in joint 8 dia. Push in joint 10 dia. 3.8 4.5 11 12 18 19 3.8 4.5 11 12 18 19 - - - - - - 3.8 4.5 10 10 17 17 ABR connection - - - - - - 3.8 4.5 10 12 17 19 PAB connection - - - - - - 4.0 4.5 13 10 19 17 sectional area 2-position mm2 3-position All ports closed 3GA2 3GA1 Descriptions 3GA3 4GA1 4GA2 4GA3 When ON When OFF When ON When OFF When ON When OFF When ON When OFF When ON When OFF When ON When OFF Response time 2-position Single Double ms 3-position ABR connection 12 12 19 19 25 28 12 12 19 19 25 - - - - - - 9 - 18 - 24 - - - - - - - 8 15 17 30 23 45 28 The value of light, surge suppressor is shown. Response time is the value at supply pressure 0.5MPa, 20 °C and not lubricated. The value varies depending on pressure and oil quality. Descriptions Single g 2-position Mass Grommet lead wire E-connector 3GA1 3GA2 3GA3 4GA1 4GA2 4GA3 58 (44) 60 (46) 115 (85) 117 (87) 162 (120) 164 (122) 58 (44) 60 (46) 120 (90) 122 (92) 171 (129) 173 (131) 3-position DIN terminal box 137 (107) 184 (142) 142 (112) 193 Double Grommet lead wire 73 (59) 135 (105) 187 E-connector 77 (63) 139 (109) 191 DIN terminal box 179 (149) 231 75 (61) 147 (117) 196 All ports Grommet lead wire E-connector 79 (65) 151 (121) 200 Block DIN terminal box 191 (161) 240 For no piping adapter, refer to the value in ( ). The value of E-connector includes the value of socket assembly (lead wire 300mm). For mass of EJ connector, add 16g/piece to mass of E-connector. 94 (151) (141) (145) (185) (154) (158) (198) 3GA1·2·3/4GA1·2·3 Series Discrete valve: Body porting 4SA/B0 4SA/B1 4GA/B MN4GA/B 4GA/B (master) MN3S0/ MN4S0 4TB 4L2-4/ LMF0 4KA/B 4F PV5/ CMF 3MA/B0 3PA/B P/M/B NP/NAP/ NVP 4F**0E HMV/ HSV Uniwire system SKH PCD/ FS/FD Discrete 3, 5 port pilot operated valve 95 3GA1/4GA1 Series Discrete valve: Body porting Internal structure and part list 3GA110-C4 C6 -* • 2-position single solenoid, N.C. Grommet lead wire(Blank) 1 2 3 4 6 5 14 7 8 9 12 11 10 13 4(A) 5(R1) 1(P) 3 (R2) 3GA1110-C4 C6 -* • 2-position single solenoid, N.O. Grommet lead wire(Blank) 1 2 3 4 5 6 14 7 9 8 10 11 12 2 (B) 5(R1) 1(P) 3 (R2) 4GA110 • 2-position single Grommet lead wire(Blank) 1 2 3 4 5 6 7 4(A) 8 9 2 (B) 11 5(R1) 96 1(P) 3 (R2) 10 11 12 13 13 3GA1/4GA1 Series Discrete valve: Body porting Internal structure and part list 4GA120 • 2-position double Grommet lead wire(Blank) 4SA/B0 1 2 3 4 5 6 7 8 9 10 13 4SA/B1 2 (B) 4(A) 4GA/B MN4GA/B 4GA/B (master) 11 11 MN3S0/ MN4S0 4TB 5(R1) 1(P) 3 (R2) 4L2-4/ LMF0 3 4GA1 45 0 4KA/B • 3-position Grommet lead wire(Blank) 4F PV5/ CMF 1 2 3 4 5 6 7 8 9 10 3MA/B0 13 2 (B) 4(A) 3PA/B P/M/B NP/NAP/ NVP 11 11 4F**0E HMV/ HSV 5(R1) 1(P) Uniwire system 3 (R2) SKH Main part list No. Repair parts list 1 Coil assembly - 2 Pilot exhaust check valve Nitrile rubber 3 Piston D assembly - 4 Manual override Resin 5 Piston room Resin 6 Protective cover of manual override Resin 7 Cartridge type quick connector - 8 Spool assembly - 9 Joint adaptor Resin 10 Body Aluminum alloy die casting 11 Piston S assembly - 12 Cap Resin 13 Piping adapter Aluminum alloy die casting 14 Plug cartridge Aluminum No. Parts name 1 Coil assembly PCD/ FS/FD Model No. 4G-[Electric connection]- * - COIL- [Voltage] Blank: Standard A: Ozone proof Discrete Material Blank: Grommet lead wire 7 4 dia. straight type 4G1-JOINT-C4 Cartridge type quick connector 6 dia. straight type 4G1-JOINT-C6 and related parts Plug cartridge 4G1-JOINT-CPG 97 3, 5 port pilot operated valve Parts name 3GA2·3/4GA2·3 Series Discrete valve: Body porting Internal structure and part list 3GA210/3GA310 • 2-position single solenoid, N.C. Grommet lead wire(Blank) 2 1 3 4 5 6 7 14 8 10 9 11 12 11 12 11 12 13 4(A) 5(R1) 1(P) 3 (R2) 3GA2110/3GA3110 • 2-position single solenoid, N.O. Grommet lead wire(Blank) 1 2 3 4 5 6 14 7 8 9 10 13 2 (B) 5(R1) 1(P) 3 (R2) 4GA210/4GA310 • 2-position single Grommet lead wire(Blank) 1 2 3 4 5 6 5(R1) 98 7 1(P) 8 9 3 (R2) 10 13 3GA2·3/4GA2·3 Series Discrete valve: Body porting Internal structure and part list 4GA220/4GA320 • 2-position double Grommet lead wire(Blank) 4SA/B0 1 2 3 4 5 6 7 8 9 10 13 4SA/B1 4GA/B MN4GA/B 4GA/B (master) MN3S0/ MN4S0 4TB 5(R1) 3 1(P) 3 (R2) 4L2-4/ LMF0 3 4GA2 45 0/4GA3 45 0 4KA/B • 3-position Grommet lead wire(Blank) 4F PV5/ CMF 1 2 3 4 5 6 7 8 4(A) 9 10 13 3MA/B0 2 (B) 3PA/B P/M/B NP/NAP/ NVP 11 4F**0E 11 HMV/ HSV 5(R1) 1(P) 3 (R2) Uniwire system SKH Main part list Repair parts list Material 1 Coil assembly - 2 Pilot exhaust check valve Nitrile rubber 3 Piston D assembly - 4 Manual override Resin 5 Piston room Resin 6 Protective cover of manual override Resin 7 Cartridge type quick connector - 8 Spool assembly - 9 Joint adaptor Resin 10 Body Aluminum alloy die casting 11 Piston S assembly - 12 Cap Resin 13 Piping adapter Aluminum alloy die casting 14 Plug cartridge Aluminum No. Parts name 1 Coil assembly PCD/ FS/FD Model No. 4G-[Electric connection]- * - COIL- [Voltage] Blank: Standard A: Ozone proof Discrete Parts name Blank: Grommet lead wire 4 dia. straight type 7 4G2-JOINT-C4 (4GA2 only) 6 dia. straight type 4G2-JOINT-C6 Cartridge type quick connector 8 dia. straight type 4G2-JOINT-C8 and related parts 10 dia. straight type 4G2-JOINT-C10 (4GA3 only) Plug cartridge 4G2-JOINT-CPG 99 3, 5 port pilot operated valve No. 3GA1·2·3/4GA1·2·3 Series Discrete valve: Body porting Internal structure and part list (Electric connection) • E-connector type (E**) 2 1 • EJ-connector type (E**J) 3 1 • DIN terminal box type (B) 1 Main part list 4 Repair parts list No. Parts name Material 1 Coil assembly 2 E-connector socket assembly - 3 Socket with cover assembly - 4 DIN terminal box assembly - No. Parts name 1 Coil assembly Model No. 4G-[Electric connection]- * - COIL- [Voltage] Blank: Standard A: Ozone proof E* : E-connector type E* J: Socket with cover type B : DIN terminal box type When B, DIN terminal box is included. 100 2 E-connector socket assembly 4G-SOCKET ASSY-E**-[Voltage] 3 Socket with cover assembly 4G-SOCKET ASSY-E**J 4 DIN terminal box assembly 4G-TERMINAL BOX-[Voltage] 3GA1 Series Discrete valve: Body porting Dimensions 3GA110 (File name: Page 239 or Ending 15) • 2-position single solenoid, N.C. grommet lead wire • M5 female thread type(M5) 102 • Mounting plate type(P) 3GA1 Series Discrete valve: Body porting Dimensions • E-connector type(E) 4SA/B0 4SA/B1 4GA/B MN4GA/B Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is 3.5mm longer. 4GA/B (master) MN3S0/ MN4S0 4TB 4L2-4/ LMF0 • EJ-connector type(E**J) 4KA/B 4F PV5/ CMF 3MA/B0 3PA/B P/M/B NP/NAP/ NVP 4F**0E HMV/ HSV Uniwire system Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is 3.5mm longer. SKH PCD/ FS/FD Discrete 3, 5 port pilot operated valve 103 3GA1 Series Discrete valve: Body porting Dimensions 3GA1110 (File name: Page 239 or Ending 15) • 2-position single solenoid, N.O. grommet lead wire • M5 female thread type(M5) 104 • Mounting plate type(P) 3GA1 Series Discrete valve: Body porting Dimensions • E-connector type(E) 4SA/B0 4SA/B1 4GA/B Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is 3.5mm longer. MN4GA/B 4GA/B (master) MN3S0/ MN4S0 4TB 4L2-4/ LMF0 • EJ-connector type(E**J) 4KA/B 4F PV5/ CMF 3MA/B0 3PA/B P/M/B NP/NAP/ NVP 4F**0E HMV/ HSV Uniwire Note. Dimensions of DC specifications are shown. system When AC100V, overall length of valve is SKH 3.5mm longer. PCD/ FS/FD Discrete 3, 5 port pilot operated valve 105 3GA2 Series Discrete valve: Body porting Dimensions 3GA210 (File name: Page 239 or Ending 15) • 2-position single solenoid, N.C. grommet lead wire • Rc1/8 female thread type(06) 2B 4A 106 • Mounting plate type(P) 3GA2 Series Discrete valve: Body porting Dimensions • E-connector type(E) 4SA/B0 4SA/B1 4GA/B Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is 3.5mm longer. MN4GA/B 4GA/B (master) MN3S0/ MN4S0 4TB • EJ-connector type(E**J) 4L2-4/ LMF0 4KA/B 4F PV5/ CMF 3MA/B0 3PA/B P/M/B NP/NAP/ NVP Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is 3.5mm longer. 4F**0E HMV/ HSV • DIN terminal box type(B) Uniwire system SKH DC 24 PCD/ FS/FD Discrete 3, 5 port pilot operated valve 107 3GA2 Series Discrete valve: Body porting Dimensions 3GA2110 (File name: Page 239 or Ending 15) • 2-position single solenoid, N.O. grommet lead wire • Rc1/8 female thread type(06) 2B 4A 108 • Mounting plate type(P) 3GA2 Series Discrete valve: Body porting Dimensions • E-connector type(E) 103: Connector axial 98: Connector radial 4SA/B0 50.5: Connector radial 45.5: Connector axial 4SA/B1 4GA/B Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is 3.5mm longer. MN4GA/B 4GA/B (master) MN3S0/ MN4S0 • EJ-connector type(E**J) 4TB 4L2-4/ LMF0 4KA/B 4F PV5/ CMF 3MA/B0 3PA/B P/M/B NP/NAP/ NVP 4F**0E Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is HMV/ 3.5mm longer. HSV Uniwire system • DIN terminal box type(B) SKH PCD/ FS/FD Discrete 109 3, 5 port pilot operated valve DC 24 3GA3 Series Discrete valve: Body porting Dimensions 3GA310 (File name: Page 239 or Ending 15) • 2-position single solenoid, N.C. grommet lead wire • Rc1/4 female thread type(08) 110 • Mounting plate type(P) 3GA3 Series Discrete valve: Body porting Dimensions • E-connector type(E) 4SA/B0 4SA/B1 4GA/B MN4GA/B 4GA/B Note. Dimensions of DC specifications are shown. (master) When AC100V, overall length of valve is 3.5mm longer. MN3S0/ MN4S0 4TB • EJ-connector type(E**J) 4L2-4/ LMF0 4KA/B 4F PV5/ CMF 3MA/B0 3PA/B P/M/B NP/NAP/ NVP 4F**0E HMV/ Note. Dimensions of DC specifications are shown. HSV When AC100V, overall length of valve is Uniwire 3.5mm longer. system SKH • DIN terminal box type(B) PCD/ FS/FD Discrete 111 3, 5 port pilot operated valve DC 24 3GA3 Series Discrete valve: Body porting Dimensions 3GA3110 (File name: Page 239 or Ending 15) • 2-position single solenoid, N.O. grommet lead wire • Rc1/4 female thread type(08) 112 • Mounting plate type(P) 3GA3 Series Discrete valve: Body porting Dimensions • E-connector type(E) 4SA/B0 4SA/B1 4GA/B MN4GA/B 4GA/B Note. Dimensions of DC specifications are shown. (master) When AC100V, overall length of valve is MN3S0/ 3.5mm longer. MN4S0 4TB • EJ-connector type(E**J) 4L2-4/ LMF0 4KA/B 4F PV5/ CMF 3MA/B0 3PA/B P/M/B NP/NAP/ NVP 4F**0E HMV/ Note. Dimensions of DC specifications are shown. HSV When AC100V, overall length of valve is Uniwire 3.5mm longer. system • DIN terminal box type(B) SKH PCD/ FS/FD Discrete 113 3, 5 port pilot operated valve DC 24 4GA1 Series Discrete valve: Body porting Dimensions 4GA110 (File name: Page 239 or Ending 15) • 2-position single grommet lead wire(Blank) • Mounting plate type(P) 49.9 (Manual override position) 12.8 19.6 1 P 10 2- 3.2 dia. fixing hole 2- 3.2 dia. 21 5 1 3-M5 5(R1),1(P),3 (R2)Port 3 P 13.5 2.2 52 R1 R2 13.5 26 • M5 female thread type(M5) M5 4 (A) port 13.5 20.2 37.4 M5 2 (B) port 1 P 114 4 17.8 49.8 (when manual cover open) 11.4 7.9 34.9 39.3 41.8 71.6 48.1: Push in joint 6 dia. 47.6: Push in joint 4 dia. Push in joint 4, 6 dia. (selection) 2 (B) port 0.7 73.8 Push in joint 4, 6 dia. (selection) 4 (A) port 4 30 22 10 12 Lead wire length 300 (AWG#26, O.D. 1.35) 4GA1 Series Discrete valve: Body porting Dimensions • E-connector type(E) 4SA/B0 84.5: Connector axial 79.5: Connector radial 4SA/B1 46: Connector radial 41: Connector axial 4GA/B 1 P Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is 3.5mm longer. MN4GA/B 4GA/B (master) MN3S0/ MN4S0 4TB • EJ-connector type(E**J) 4L2-4/ LMF0 4KA/B 4F 110.5: Connector axial 79.5: Connector radial PV5/ CMF 3MA/B0 72: Connector radial 41: Connector axial 3PA/B P/M/B NP/NAP/ NVP 1 P Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is 3.5mm longer. 4F**0E HMV/ HSV Uniwire system SKH PCD/ FS/FD Discrete 3, 5 port pilot operated valve 115 4GA1 Series Discrete valve: Body porting Dimensions 4GA120 (File name: Page 239 or Ending 15) • 2-position double grommet lead wire(Blank) • Mounting plate type(P) 22.3 47.9 (Manual override position) 12.8 39.8 Push in joint 4, 6 dia. (selection) 2 (B) port Push in joint 4, 6 dia. (selection) 4 (A) port 4 30 22 10 12 Lead wire length 300 (AWG#26, O.D. 1.35) 4 17.8 2- 3.2 dia. 10 103.8 2- 3.2 dia. fixing hole 48.1: Push in joint 6 dia. 47.6: Push in joint 4 dia. 49.8 (when manual cover open) 11.4 1 P 1 P 7.9 39.3 41.8 92.5 21 20.2 11.3 52 5 1 3 R1 P 13.5 R2 13.5 3-M5 5(R1),1(P),3 (R2)Port 46.3 • M5 female thread type(M5) 13.5 M5 4 (A) port 40.5 37.4 M5 2 (B) port 1 P 116 4GA1 Series Discrete valve: Body porting Dimensions • E-connector type(E) 4SA/B0 118: Connector axial 4SA/B1 109: Connector radial 41: Connector axial 46: Connector radial 4GA/B MN4GA/B 1 P Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is 7mm longer. 4GA/B (master) MN3S0/ MN4S0 4TB 4L2-4/ LMF0 • EJ-connector type(E**J) 4KA/B 4F PV5/ CMF 170: Connector axial 109: Connector radial 3MA/B0 3PA/B NP/NAP/ NVP 4F**0E 41: Connector axial 72: Connector radial P/M/B HMV/ HSV 1 P Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is Uniwire system 7mm longer. SKH PCD/ FS/FD Discrete 3, 5 port pilot operated valve 117 4GA1 Series Discrete valve: Body porting Dimensions 3 4GA145 0 (File name: Page 239 or Ending 15) • 3-position grommet lead wire(Blank) • Mounting plate type(P) 55.9 (Manual override position) 12.8 12 30 22 47.8 10 Lead wire length 300 (AWG#26, O.D. 1.35) 22.3 (Manual override position) 17.8 2- 3.2 dia. 4 4 Push in joint 4, 6 dia. (selection) 2 (B) port Push in joint 4, 6 dia. (selection) 4 (A) port 1 P 2- 3.2 dia. fixing hole 10 111.8 49.8 (when manual cover open) 48.1: Push in joint 6 dia. 47.6: Push in joint 4 dia. 11.4 39.3 7.9 41.8 100.5 21 52 11.3 28.2 5 1 3-M5 5(R1), 1(P), 3(R2) Port 3 P R1 13.5 R2 13.5 54.2 • M5 female thread type(M5) 11.6 M5 4(A)Port 48.5 37.4 M5 2 (B)Port 1 P 118 4GA1 Series Discrete valve: Body porting Dimensions • E-connector type(E) 4SA/B0 126: Connector axial 117: Connector radial 4SA/B1 41: Connector axial 46: Connector radial 4GA/B MN4GA/B 1 P Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is 7mm longer. 4GA/B (master) MN3S0/ MN4S0 4TB • EJ-connector type(E**J) 4L2-4/ LMF0 4KA/B 4F 178: Connector axial 117: Connector radial PV5/ CMF 3MA/B0 3PA/B NP/NAP/ NVP 41: Connector axial 72: Connector radial P/M/B 4F**0E 1 P Note. Dimensions of DC specifications are shown. HMV/ HSV When AC100V, overall length of valve is 7mm longer. Uniwire system SKH PCD/ FS/FD Discrete 3, 5 port pilot operated valve 119 4GA2 Series Discrete valve: Body porting Dimensions 4GA210 (File name: Page 239 or Ending 15) • 2-position single grommet lead wire(Blank) • Mounting plate type(P) 67.5 (Manual override position) 14.6 26.7 Push in joint 4, 6, 8 dia. (selection) 4 (A) port 5 2-2 Push in joint 4, 6, 8 dia. (selection) 2 (B)Port 93.7 46.4 4 14 43.9 2- width 4.4 oval hole 65.1: Push in joint 4, 6, 8 dia. common 4.3 89.7 46.4 25 36 27 10 19.4 Lead wire length 300 (AWG#26, O.D. 1.35) 17 17 5.8 62.6 2.7 4 17 0.5 4- 3.2 dia. fixing hole 3-Rc1/8 5(R1),1(P), 3(R2)Port 17 17 31.3 • Rc1/8 female thread type(06) 2B Rc1/8 4 (A) port 16 26 Rc1/8 2 (B) port 49.9 4A 120 4GA2 Series Discrete valve: Body porting Dimensions • E-connector type(E) 103: Connector axial 98: Connector radial 4SA/B0 50.5: Connector radial 45.5: Connector axial 4SA/B1 4GA/B MN4GA/B Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is 3.5mm longer. 4GA/B (master) MN3S0/ MN4S0 4TB • EJ-connector type(E**J) 4L2-4/ LMF0 4KA/B 4F 129: Connector axial 98: Connector radial PV5/ CMF 3MA/B0 3PA/B 76.5: Connector radial 45.5: Connector axial P/M/B NP/NAP/ NVP 4F**0E Note. Dimensions of DC specifications are shown. HMV/ HSV When AC100V, overall length of valve is 3.5mm longer. Uniwire system SKH • DIN terminal box type(B) PCD/ FS/FD Discrete 121 3, 5 port pilot operated valve DC 24 4GA2 Series Discrete valve: Body porting Dimensions 4GA220 (File name: Page 239 or Ending 15) • 2-position double grommet lead wire(Blank) • Mounting plate type(P) 22.2 67 (Manual override (Manual override position) position) 14.6 48.4 5 25 2-2 123.2 4 14 46.4 43.9 2- width 4.4 oval hole 65.1: Push in joint 4, 6, 8 dia. common Push in joint 4, 6, 8 dia. (selection) 2 (B) port 111.4 47.9 Push in joint 4, 6, 8 dia. (selection) 4 (A) port 4.3 36 27 19.4 Lead wire length 300 (AWG#26, O.D. 1.35) 17 5.8 17 62.6 24.4 11.8 17 0.5 4- 3.2 dia. fixing hole 3-Rc1/8 5(R1),1(P),3 (R2)Port 17 17 31.3 • Rc1/8 female thread type(06) 2B 4A Rc1/8 4 (A) port 16 26 49.9 Rc1/8 2 (B) port 122 4GA2 Series Discrete valve: Body porting Dimensions • E-connector type(E) 137: Connector axial 128: Connector radial 4SA/B0 4SA/B1 50.5: Connector radial 45.5: Connector axial 4GA/B MN4GA/B Note. Dimensions of DC specifications are shown. 4GA/B (master) When AC100V, overall length of valve is 7mm longer. MN3S0/ MN4S0 4TB 4L2-4/ LMF0 • EJ-connector type(E**J) 4KA/B 4F PV5/ CMF 189: Connector axial 128: Connector radial 3MA/B0 3PA/B 76.5: Connector radial 45.5: Connector axial P/M/B NP/NAP/ NVP 4F**0E HMV/ HSV Note. Dimensions of DC specifications are shown. Uniwire When AC100V, overall length of valve is system 7mm longer. SKH • DIN terminal box type(B) PCD/ FS/FD Discrete 123 3, 5 port pilot operated valve DC 24 4GA2 Series Discrete valve: Body porting Dimensions 3 4GA2450 (File name: Page 239 or Ending 15) • 3-position grommet lead wire(Blank) • Mounting plate type(P) 78.7 (Manual override position) Lead wire length 300 22.3 (Manual override 60.2 14.6 5 position) 25 2-2 17 17 5.8 62.6 36 27 4 17 4- 3.2 dia. 135 47.9 14 43.9 46.4 123.2 2- width 4.4 oval hole 65.1: Push in joint 4, 6, 8 dia. common Push in joint 4, 6, 8 dia. (selection) 2 (B) port Push in joint 4, 6, 8 dia. (selection) 4 (A) port 4.3 10 19.4 (AWG#26, O.D. 1.35) 36.2 17 3-Rc1/8 5(R2),1(P),3(R1)Port 17 31.3 • Rc1/8 female thread type(06) 2B 4A Rc1/8 4 (A) port 16 26 49.9 Rc1/8 2 (B) port 124 11.8 0.5 fixing hole 4GA2 Series Discrete valve: Body porting Dimensions • E-connector type(E) Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is 7mm longer. 149: Connector axial 140: Connector radial 4SA/B0 4SA/B1 4GA/B 4GA/B 45.5: Connector axial 50.5: Connector radial MN4GA/B (master) MN3S0/ MN4S0 4TB 4L2-4/ LMF0 • EJ-connector type(E**J) 4KA/B 4F Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is 7mm longer. 201: Connector axial 140: Connector radial PV5/ CMF 3MA/B0 3PA/B P/M/B 4F**0E HMV/ HSV 45.5: Connector axial 76.5: Connector radial NP/NAP/ NVP Uniwire system SKH PCD/ FS/FD 24 82 DC 164.5 (DIN terminal box extrinsic direction) Discrete MAX10 161.2 (DIN terminal box intrinsic direction) 125 3, 5 port pilot operated valve • DIN terminal box type(B) 4GA3 Series Discrete valve: Body porting Dimensions 4GA310 (File name: Page 239 or Ending 15) • 2-position single grommet lead wire(Blank) • Mounting plate type(P) 75.9 Lead wire length 300 (AWG#26, O.D. 1.35) 16.6 10 20.5 30.1 7.25 36.9 18.5 Push in joint 6, 8, 10 dia. (selection) 2 (B) port Push in joint 6, 8, 10 dia. (selection) 4 (A) port 35.9 27.3 2-5 3-Rc1/4 5(R1),1(P),3 (R2)Port 20 3.7 6.3 20 37.9 • Rc1/4 female thread type(08) 19.8 28.5 Rc1/4 4 (A) port 58.7 Rc1/4 2 (B) port 126 2- width 4.5 oval hole 101.8 75.6: Push in joint 10 dia. 70.6: Push in joint 6, 8 dia. common 51.5 5.5 63 75.7 2- 4.5 dia. fixing hole 17.8 48 50.6 4.3 98.2 4GA3 Series Discrete valve: Body porting Dimensions • E-connector type(E) 111: Connector axial 106: Connector radial 4SA/B0 4GA/B 49.5: Connector axial 54.5: Connector radial 4SA/B1 Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is 3.5mm longer. MN4GA/B 4GA/B (master) MN3S0/ MN4S0 4TB • EJ-connector type(E**J) 4L2-4/ LMF0 4KA/B 4F 137: Connector axial 106: Connector radial PV5/ CMF 3PA/B P/M/B 49.5: Connector axial 80.5: Connector radial 3MA/B0 Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is 3.5mm longer. NP/NAP/ NVP 4F**0E HMV/ HSV Uniwire system • DIN terminal box type(B) SKH PCD/ FS/FD Discrete 127 3, 5 port pilot operated valve DC 24 4GA3 Series Discrete valve: Body porting Dimensions 4GA320 (File name: Page 239 or Ending 15) • 2-position double grommet lead wire(Blank) 75.2 22.3 (Manual override position) 16.6 (Manual override position) 51.6 7.25 36.9 2-5 Push in joint 6, 8, 10 dia. (selection) 4 (A) port 4.3 Push in joint 6, 8, 10 dia. (selection) 2 (B) port 75.7 20 3-Rc1/4 22 20 59.8 5(R1),1(P),3 (R2)Port • Rc1/4 female thread type(08) Rc1/4 4 (A) port 19.8 49.9 58.7 Rc1/4 2 (B) port 128 132.2 75.6: Push in joint 10 dia. 70.6: Push in joint 6, 8 dia. common 2- width 4.5 oval hole 12.6 6.3 63 5.5 17.8 50.6 48 51.7 119.7 2- 4.5 dia. fixing hole 18.5 35.9 27.3 10 20.5 Lead wire length 300 (AWG#26, O.D. 1.35) • Mounting plate type(P) 4GA3 Series Discrete valve: Body porting Dimensions • E-connector type(E) 145.5: Connector axial 136: Connector radial 4SA/B0 54.5: Connector radial 49.5: Connector axial 4SA/B1 4GA/B Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is 7mm longer. MN4GA/B 4GA/B (master) MN3S0/ MN4S0 4TB • EJ-connector type(E**J) 4L2-4/ LMF0 4KA/B 4F PV5/ CMF 197.5: Connector axial 136: Connector radial 3MA/B0 3PA/B 80.5: Connector radial 49.5: Connector axial P/M/B NP/NAP/ NVP 4F**0E Note. Dimensions of DC specifications are shown. HMV/ When AC100V, overall length of valve is HSV 7mm longer. Uniwire system SKH PCD/ FS/FD Discrete DC 24 129 3, 5 port pilot operated valve • DIN terminal box type(B) 4GA3 Series Discrete valve: Body porting Dimensions 3 4GA3450 (File name: Page 239 or Ending 15) • 3-position grommet lead wire(Blank) • Mounting plate type(P) 87.2 (Manual override position) 16.6 Lead wire length 300 (AWG#26, O.D. 1.35) 22.3 (Manual override position) 63.6 7.25 36.9 4.3 Push in joint 6, 8, 10 dia. (selection) 2 (B) port Push in joint 6, 8, 10 dia. (selection) 4 (A) port 18.5 35.9 27.3 10 20.5 2-5 2- width 4.5 oval hole 3-Rc1/4 20 5(R1),1(P),3 (R2)Port 34 20 37.9 • Rc1/4 female thread type(08) Rc1/4 4 (A) port 19.8 61.9 58.7 Rc1/4 2 (B) port 130 144.3 12.6 6.3 75.6: Push in joint 10 dia. 70.6: Push in joint 6, 8 dia. common 51.7 63.1 75.7 2- 4.5 dia. fixing hole 5.5 17.8 48 50.6 131.7 4GA3 Series Discrete valve: Body porting Dimensions • E-connector type(E) 4SA/B0 157.5: Connector axial 148: Connector radial 4SA/B1 54.5: Connector radial 49.5: Connector axial 4GA/B MN4GA/B Note. Dimensions of DC specifications are shown. When AC100V, overall length of valve is 7mm longer. 4GA/B (master) MN3S0/ MN4S0 4TB • EJ-connector type(E**J) 4L2-4/ LMF0 4KA/B 4F PV5/ CMF 209.5: Connector axial 148: Connector radial 3MA/B0 3PA/B NP/NAP/ NVP 49.5: Connector axial 80.5: Connector radial P/M/B 4F**0E HMV/ Note. Dimensions of DC specifications are shown. HSV When AC100V, overall length of valve is Uniwire 7mm longer. system SKH • DIN terminal box type(B) PCD/ FS/FD Discrete 24 131 3, 5 port pilot operated valve DC
Similar documents
MAGNETIC BUBBLE APPARATUS
magnetizing field H is applied, magnetization occurrs by the growth of one domain at the xpense of the others. The intensity of light transmitted through FMG is proportional to the magnetization M,...
More informationCKD Pneumatic Valves
Air supply/exhaust air method Pilot exhaust Internal pilot External pilot air method Piping direction Working fluid Valve and solenoid type Min. working pressure MPa Max. working pressure MPa Withs...
More information4F0/1/2/3Series - CKDPneumatic.com
Discrete valve: Body porting MN3E0 Internal structure and parts list MN4E0 4GA/B
More information