air filter media - Filterservice Heerenveen
Transcription
air filter media - Filterservice Heerenveen
AIR FILTER MEDIA • Pre and Coarse Filtration Barrier to the air intake systems in general ventilation and air handling systems •UL Class 1 and self extinguishing according DIN 53438-F1 • 100% Synthetic DESCRIPTION FLAMMABILITY RATINGS Filtrair VNF-300/PSF-300 conform to German fire classification standards (DIN 53438-F1) and is self-extinguishing. It is resistant to evaporated solvents and is produced in a 100% silicone-free environment. FEATURES AND BENEFITS Filtrair VNF-300/PSF-300 are specially designed to be used in Filtrair G4 HVAC media VNF-300 and PSF-300 are designed for coarse filtration of the air intake in general ventilation and air handling systems installed in public buildings, offices, factories and equipment of all kinds. The products are suited for high air volume applications which are heavily contaminated. The Filtrair G4 HVAC media combine a high dust holding capacity with a low pressure drop and are therefore extremely cost effective with a long filter life. •GENERAL AIR HANDLING UNITS •AIR CONDITIONING SYSTEMS •VENTILATION SYSTEMS OF ALL KINDS •AIR INTAKE PRE-FILTRATION BANKS •HOUSE HOLD APPLICATIONS •RAILROAD CAR VENTILATION •INTAKE AND EXHAUST AIR SYSTEMS FOR HEAVY INDUSTRY AND CHEMICAL PLANTS Synthetic fiber-based filter media developed and produced at Filtrair high-tech media plant based in The Netherlands. The filter media are constructed from selected high performance, non-breakable fibers in a progressive density multi-layering technique to ensure high depth loading with optimal lowest pressure drop performance, to achieve gravimetric arrestance in accordance with EN 779:2012 standard ratings. SPECIALTY PRODUCTS Filtrair can offer other G4 specialty products upon request. These products will cover fire rating standards according NF-P92-503/504, wash ability requirements and any other special purpose. Technical data are available upon request. VNF-300 and PSF-300 are thermally bonded to prevent fiber release. The clean air sides can be imprinted for easy identification to ensure the correct installation in pad, roll or pocket format. PSF-300 requires minimum order quantities. Member of Filtration Group® PRESSURE DROP vs AIR FLOW RATE PRESSURE DROP vs AIR FLOW RATE PRE SS UREDROP DROP(Pa) (Pa) PRE SS URE 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 V NF-290 V NF-290 0 0 1.500 1.500 3.000 3.000 4.500 4.500 PSF-200 PSF-200 6.000 6.000 7.500 7.500 AIR FLOW RATE (m³/h) AIR FLOW RATE (m³/h) APPLICATION PARAMETERS Product VNF-300 Temperature Resistance Up to 100oC Temp. short peaks Up to 120oC Nominal thickness 22 mm +/- 2 Relative humidity 100% Roll sizes standard 2 m x 20 m 1 m x 20 m Regenerable / washable yes DUST LOADING vs ARRESTANCE VS PRESSURE DROP DUST LOADING vs ARRESTANCE VS PRESSURE DROP 90 450 90 450 80 400 80 400 70 350 70 350 60 300 60 300 50 250 50 250 40 200 40 200 30 150 30 150 20 100 20 100 10 50 10 50 Arrestance Pressure drop Arrestance Pressure drop 0 0 0 0 0 100 200 300 400 500 600 0 100 200 300 400 2 500 600 DUST LOADING (g/m2) DUST LOADING (g/m ) PSF-300 Up to 100oC Up to 120oC 22 mm +/- 3 100% 2 m x 20 m 1 m x 20 m yes DUST LOADING vsPSF-300 ARRESTANCE vs PRESSURE DROP PSF-300 PSF-300 DUST LOADING vs ARRESTANCE VS PRESSURE DROP DUST LOADING vs ARRESTANCE VS PRESSURE DROP 90 450 90 450 80 400 80 400 70 350 70 350 60 300 60 300 50 250 50 250 40 200 40 200 30 150 30 150 20 100 20 100 10 50 10 50 Arrestance Pressure drop Arrestance Pressure drop 0 0 0 0 0 100 200 300 400 500 600 0 100 200 300 400 2 500 600 DUST LOADING (g/m2) DUST LOADING (g/m ) ARRESTANCE(%) (%) ARRESTANCE PRESSURE DROP VS AIR FLOW RATE VNF-300/PSF-300 VNF-300 / PSF-300 PRESSURE DROP vs AIR FLOW RATE 70 PRE SS URE DROP (Pa) VNF-300 VNF-300 60 50 40 30 20 10 V NF-290 Filtrair B.V. PSF-200 De Werf 16 8447 GE Heerenveen PO Box 611 8440 AP Heerenveen The Netherlands P. +31 (0) 513-626 355 F. +31 (0) 513-627 306 E. marketing@filtrair.com www.filtrair.com 0 0 1.500 3.000 4.500 6.000 7.500 AIR FLOW RATE (m³/h) VNF-300 90 450 80 400 70 350 60 300 50 250 40 200 30 150 20 100 PRE SS URE DROP (Pa) ARRESTANCE (%) DUST LOADING vs ARRESTANCE VS PRESSURE DROP 10 PRE SS UREDROP DROP(Pa) (Pa) PRE SS URE VNF-300 PSF-300 5.400 1,5 m/sec 42 Pa 250 Pa 91% 460 g/m2 G4 PRE SS UREDROP DROP(Pa) (Pa) PRE SS URE Filter Class acc. EN 779:2012 DUST LOADING vs ARRESTANCE vs PRESSURE DROP VNF-300 5.400 1,5 m/sec 42 Pa 250 Pa 91% 500 g/m2 G4 ARRESTANCE(%) (%) ARRESTANCE PERFORMANCE DATA Product Rated Air Flow (m3/h/m2) Rated Air Flow Velocity Initial Resistance Final Resistance Average Arrestance Dust holding capacity 50 Arrestance 0 Pressure drop 0 200 300 400 500 600 VNF-300-PSF-300-124001061-V1 DUST LOADING (g/m2) All data are average indicative values with usual manufacturing and testing tolerances. We reserve the right to modify performance data without prior notice. Specific performance data will require our written confirmation. Filtrair ® is the registered trade mark of Filtrair bv. 0 100 PSF-300 Member of Filtration Group®