foot grille systems roof hatch and exutoire

Transcription

foot grille systems roof hatch and exutoire
w
w
w
.
b
o
l
a
r
.
c
o
m
FOOT GRILLE SYSTEMS
ROOF HATCH AND EXUTOIRE
TECHNICAL SPECIFICATION AND MANUAL
GRILLAGE BOLAR (CANADA) INC.
50 Omer de Serres
Blainville, Quebec
J7C 5H2
Phone: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
Internet: http://www.bolar.com
e-mail: webmaster@bolar.com
TABLE OF CONTENTS
FOOT GRILLES GENERAL INFORMATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Aluminum finishes: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Frames: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Pans: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
POSSIBLE APPLICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
ACCESSORIES/OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Option #1: Hinges and lock notch: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Option #2: Hinges and lock notch with GB-46 lock downs: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Option #3: Lock downs GB-46 (4 per grilles): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Option #4: Plates and screws:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Option #5: Lifting hooks: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Option #6: Sound gasket: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
BA-5 Foot grilles: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
BA-1 Foot grilles: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
BA-12 Foot grilles: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8
BA-125 Foot grilles:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10
BA-1-3 Foot grilles: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12
BA-1-3-HL Foot grilles: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-14
BA-2 Foot grilles: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-16
BA-3/4 Foot grilles: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17-18
BC-6 Foot grilles: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
BC-1 or BC-7 Foot grilles: (See description) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-21
BC-2 Isomat: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
BCH-4 Foot grilles: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23-24
BLA-1 Foot grilles: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-26
BSA-1 Foot grilles: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27-28
BSA-1-3 Foot grilles: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29-30
BC-5 Isomat: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
BSA-4 Foot grilles: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-33
BSV-1 Foot grilles:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-35
BSV-2 Isomat: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
BSV-3 Foot grilles:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37-38
BV-1 Foot grilles:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39-40
BSP-90 Foot grilles: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41-42
BV-2 Isomat: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
BV-3 Foot grilles:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44-45
SIGNATURE SERIES FOOT GRILLES: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
CO33 Foot grilles: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47-48
CO234 Foot grilles: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49-50
CO34 Foot grilles: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51-52
CO40 Foot grilles: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53-54
General:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
OPTIONS:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
PREVENTIVE MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
TILE REPLACEMENT AND ROTATION: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56-57
DRY FOAM EXTRACTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
FREQUENCY CHART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59-60-61
CHART A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
CHART B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
CHART II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
CHART V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
CHART VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
CHART VII. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
TABLE OF RESULTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
ROOF HATCH AND SMOKE HATCH: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
SPÉCIFICATIONS: BOLAR MODEL “G” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
SPECIFICATIONS: BOLAR MODEL “A” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
SPECIFICATIONS: BOLAR MODEL “AG” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
SPECIFICATIONS: BOLAR MODEL "GR " . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
SPECIFICATIONS: BOLAR MODEL “AR”. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
SPECIFICATIONS: BOLAR MODEL “AGR” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
SPECIFICATIONS: BOLAR MODEL “SH” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Printing >>>
FOOT GRILLES GENERAL INFORMATIONS
Bolar (Canada) Inc. also offers, as options, these different products and services:
Aluminum finishes:
All our aluminum components are mill finish as a standard. However, they are also available in a variety of anodized colors A (.008). We do not
recommend anodizing surfaces that will come in contact with people traffic, for this will affect the anodized surfaces. Anodizing is best used for
ventilation purposes in order to blend in with existing design.
Frames:
Bolar (Canada) Inc. offers a wide variety of frames such as stainless steel, brass, steel. These are available only for the "AD" type frames. On the
"VV" type we may provide you with a cap of such materials, in order to improve design.
Pans:
Pans are offered in a variety of materials such as stainless steel, aluminum, brass or galvanized steel. Pans of 22 gauge are recommended, other
gauges in stock. Stainless steel offers the maximum durability. The depth of our pans can be modified as per your specifications.
POSSIBLE APPLICATIONS
Besides the obvious Bolar grilles have a wide variety of applications.
They are used in entrance ways in order to provide cleaner and safer vestibules, by removing corrosive salt and water.
They are used as vents in large and small sizes. Model BA-2 provides high air circulation without the backdraft effects. The spacing can be
adjusted to your specification in order to obtain proper air circulation.
They can be reinforced so as to accept car circulation. eg: shopping mall expositions, or forklift traffic eg: warehouses (BA-1-3-HL) etc.
Unaffected by water it is a highly durable drainage cover providing for high water circulation and anti-slip surface.
They are also used as tree grates in shopping malls, restaurants etc. Model BSA-1 will provide a great design, anti-slip surface, and will keep papers,
and people, out of tree wells. Thus cutting down maintenance time and increasing safety.
Model BSP-90 is specially designed for shower and sauna uses. It is composed of a soft flexible, rounded 55/65 vinyl with an "anti-fungal"
protection. This provides a soft anti-slip surface that is easily cleaned. It is also ideal as pool contours. All grilles can be cut to irregular shapes, so
as to match floor design. You are not limited to rectangles.
Triangular or even rounded shapes can be manufactured. With our model BA-2, the blades can even be shaped in a circular fashion. This makes it
perfect for revolving door applications. If an irregular shape is needed for your project, the hinges and lock (option #1) cannot be installed, only
security lock set on 4 corners.
NOTE: For circular areas a template would be required to ensure a precise fit on existing conditions. In some cases it may be impossible to include
hinges and lock notch, please check with your representative.
WE ALSO MANUFACTURE ROOF HATCHES.
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch: (except on irregular shape)
All sections of grille will be supplied with hinges and lock notch. The hinges and lock notch will be fabricated in stainless steel and installed on the
grille by the manufacturer. They will be attached to the frame by the general contractor and verified by the architect prior to final approbation.
Option #2: Hinges and lock notch with GB-46 lock downs: (except on irregular shape)
All sections of grilles will be supplied with a combination hinges/lock notch and lock downs model GB-46. The hinges and lock notch will be
fabricated in stainless steel and installed on the grille by the manufacturer. The lock downs will be fabricated of galvanized steel and Teflon, they
will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for easy of operation (one per
vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general contractor. We suggest they be
greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
2
Printing >>>
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces (one
per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible
accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
This section is not a standard, you have to specify if needed.
section: 12482
buyline: 8254
3
Printing >>>
BA-5 Foot grilles:
1) To supply and install to location and sizes Bolar Isomat manufactured under a proven quality system model BA-5 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The Isomat BA-5 shall be so conceived so as to accept a minimum uniform load of 120 Newton applied over a 4 inch square (100mm) surface in
order to obtain a 1/180" deflection over a 2'-0" (610mm) span.
4) The perimeter frames shall be "˚ " inverted such as model "WW" by Bolar, for anchoring in concrete.
OR
The perimeter frames shall be " Î " such as model "WW"I by Bolar, for anchoring in concrete.
OR
The mat will be supplied with a "SSA" type frame by Bolar. Consisting of an anti-slip aluminum extrusion with beveled edge, attached to the mat
on two surfaces.
5) The blades of the BA-5 matting are grooved and made from aluminum alloy 6063-T5. The grooves ensure that it is slip resistant. The blades are
joined together by a flexible vinyl hinge which allows the matting to be rolled during maintenance. This same vinyl link protects floor finishes
against scratches and ensures that the product makes no noise when people walk on it. Option #1 is available on request to clip the vinyl link every
300 mm (12 in) to allow water to drip into the drain when necessary.
6) Spacing between blades and vinyl hinge shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will be
manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 0,92 and a cleaning efficiency of 76 %, percentage of opening shall be 10 %
9) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
10) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The Isomat BA-5 sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square
and level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. Protect grilles
from construction traffic.
ACCESSORIES / OPTIONS
Option #1: Water run off
The vinyl hinges are notched every 300mm (12") in order to allow water to flow under the mat and into the pit area.
section: 12482
buyline: 8254
4
Printing >>>
BA-1 Foot grilles:
1) To supply and install to location and sizes foot grilles manufactured under a proven quality system model: BA-1 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 1560 Newton applied over a 4" (100mm) square surface in order
to obtain a 1/180" deflection over a 4'-0" (1220 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. For sections larger than 6'-0 * 8'-0 (1828mm x
2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. For sections larger than 6'-0 *
8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified). A silicone joint is to be applied between the frame and the finished
floor to prevent any water infiltration (by others).
5) Blades shall be "T" shaped, size: 3/8" * 1/8" * 1" (9.5mm * 3mm * 25mm). Spacing between blades is not to exceed 3/16" (4.7mm). Such as
model BA-1 by Bolar. Overall depth: 2" (50mm) from finished floor.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel. Coat all surfaces in contact with masonry with two coats of
bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 1,26 and a cleaning efficiency of 48 %, percentage of opening shall be 37%.
9) The deformation under lateral charge is not to exceed 11 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges (if
required). Verify that all latches are in a closed position and properly greased (if required)
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch: ( excepted on irregular shape)
All sections of grille will be supplied with hinges and lock notch. The hinges and lock notch will be fabricated in stainless steel and installed on the
grille by the manufacturer. They will be attached to the frame by the general contractor and verified by the architect prior to final approbation.
Option #2: Hinges and lock notch with GB-46 lock downs: ( excepted on irregular shape)
All sections of grilles will be supplied with a combination hinges/lock notch and lock downs model GB-46. The hinges and lock notch will be
fabricated in stainless steel and installed on the grille by the manufacturer. The lock downs will be fabricated of galvanized steel and Teflon, they
will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for easy of operation (one per
vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general contractor. We suggest they be
greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
5
Printing >>>
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces (one
per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible
accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer’s specifications. The sound gasket’s function will be to buffer noise
and vibrations that could occur between frames and blades.
section: 12482
buyline: 8254
6
Printing >>>
BA-12 Foot grilles:
1) To supply and install to location and sizes foot grilles manufactured under a proven quality system model: BA-12 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 2740 Newton applied over a 4" (100mm) square surface in order
to obtain a 1/180" deflection over a 4'-0" (1220 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. For sections larger than 6'-0 * 8'-0 (1828mm x
2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. For sections larger than 6'-0 *
8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified). A silicone joint is to be applied between the frame and the finished
floor to prevent any water infiltration (by others).
5) Blades shall be "T" shaped, size: 3/8" * 1/8" * 1 1/4" (9.5mm * 3mm * 50mm). Spacing between blades is not to exceed 3/16" (4.7mm). Such
as model BA-12 by Bolar. Overall depth: 3" (58mm) from finished floor.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel. Coat all surfaces in contact with masonry with two coats of
bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 1,26 and a cleaning efficiency of 48 %, percentage of opening shall be 37%.
9) The deformation under lateral charge is not to exceed 11 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges (if
required). Verify that all latches are in a closed position and properly greased (if required).
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch: (not available for this model)
Option #2: Hinges and lock notch with GB-46 lock downs: (not available for this model)
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
7
Printing >>>
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces (one
per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible
accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section:12482
buyline: 8254
8
Printing >>>
BA-125 Foot grilles:
1) To supply and install to location and sizes foot grilles manufactured under a proven quality system model: BA-125 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 1794 Newton applied over a 4" (100mm) square surface in order
to obtain a 1/180" deflection over a 4'-0" (1220 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. For sections larger than 6'-0 * 8'-0 (1828mm x
2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. For sections larger than 6'-0 *
8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified). A silicone joint is to be applied between the frame and the finished
floor to prevent any water infiltration (by others).
5) Blades shall be "T" shaped, size: 3/8" * 1/8" * 1 1/4" (9.5mm * 3mm * 32mm). Spacing between blades is not to exceed 3/16" (4.7mm). Such
as model BA-125 by Bolar. Overall depth: 2 1/4" (58mm) from finished floor.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel. Coat all surfaces in contact with masonry with two coats of
bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 1,26 and a cleaning efficiency of 48 %, percentage of opening shall be 37%.
9) The deformation under lateral charge is not to exceed 11 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges (if
required). Verify that all latches are in a closed position and properly greased (if required).
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch: (not available for this model)
Option #2: Hinges and lock notch with GB-46 lock downs: (not available for this model)
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
9
Printing >>>
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille
surfaces (one per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible
accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section: 12482
buyline: 8254
10
Printing >>>
BA-1-3 Foot grilles:
1) To supply and install to location and sizes Bolar foot grilles manufactured under a proven quality system model: BA-1-3 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 1760 Newton applied over a 4 square inch (100mm) surface in
order to obtain a 1/180" deflection over a 4'-0" (1220 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. For sections larger than 6'-0 * 8'-0 (1828mm x
2438mm) a mechanical joint is to be provided, (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. For sections larger than 6'-0 *
8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified). A silicone joint is to be applied between the frame and the finished
floor to prevent any water infiltration (by others).
5) Blades shall be "T" shaped, size: 3/16" * 1/8" * 1" (4.7mm * 3mm * 25mm). Spacing between blades is not to exceed 3/16" (4.7mm). Such as
model BA-1-3 by Bolar. Overall depth: 2" (50mm) from finished floor.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel. Coat all surfaces in contact with masonry with two coats of
bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 1,19 and a cleaning efficiency of 51 %, percentage of opening shall be 56%.
9) The deformation under lateral charge is not to exceed 14 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges, (if
required). Verify that all latches are in a closed position, and properly greased (if required).
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch:
All sections of grille will be supplied with hinges and lock notch. The hinges and lock notch will be fabricated in stainless steel and installed on the
grille by the manufacturer. They will be attached to the frame by the general contractor and verified by the architect prior to final approbation.
Option #2: Hinges and lock notch with GB-46 lock downs:
All sections of grilles will be supplied with a combination hinges/lock notch and lock downs model GB-46. The hinges and lock notch will be
fabricated in stainless steel and installed on the grille by the manufacturer. The lock downs will be fabricated of galvanized steel and Teflon, they
will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for easy of operation (one per
vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general contractor. We suggest they be
greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
11
Printing >>>
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces (one per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible
accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section: 12482
buyline: 8254
12
Printing >>>
BA-1-3-HL Foot grilles:
1) To supply and install to location and sizes Bolar foot grilles manufactured under a proven quality system model: BA-1-3-HL as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 7300 Newton applied over a 4" (100mm) square surface in order
to obtain a 1/180" deflection over a 4'-0" (1220 mm) span.
4) The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. For sections larger than 6'-0 * 8'-0 (1828mm x
2438mm) a mechanical joint is to be provided, (if specified).
5) Blades shall be "T" shaped, size: 3/16" * 1/8" * 2 1/2" (4.7mm * 3mm * 63mm). Spacing between blades is not to exceed 3/16" (4.7mm). Such
as model BA-1-3-HL by Bolar. Overall depth: 3 1/2" (90mm) from finished floor.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel. Coat all surfaces in contact with masonry with two coats of bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 1,19 and a cleaning efficiency of 51 %, percentage of opening shall be 56%.
9) The deformation under lateral charge is not to exceed 16 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges, (if
required). Verify that all latches are in a closed position and properly greased, (if required).
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch: [Not available for this model]
Option #2: Hinges and lock notch with GB-46 lock downs: [Not available for this model]
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces (one
per vestibule).
13
Printing >>>
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible
accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section: 12482
buyline: 8254
14
Printing >>>
BA-2 Foot grilles:
1) To supply and install to location and sizes Bolar foot grilles manufactured under a proven quality system model: BA-2 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 4340 Newton applied over a 4 square inch (100mm) surface in
order to obtain a 1/180" deflection over a 4'-0" (1220 mm) span. (BA-2: 1/8 x 1" ou 3mm x 25mm)
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. For sections larger than 6'-0 * 8'-0 (1828mm x
2438mm) a mechanical joint is to be provided, (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. For sections larger than 6'-0 *
8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified). A silicone joint is to be applied between the frame and the finished
floor to prevent any water infiltration (by others).
5) Blades shall be rectangular shape size:
size:
1/8" * 3/4" (3mm * 19mm)
OR
1/8" * 1" (3mm * 25mm)
OR
3/16" * 1" (4.7mm * 25mm)
OR
1/4" * 1" (6.4mm * 25mm)
OR
3/16" * 1 1/2" (4.7mm * 38mm)
OR
3/16" * 2 1/2" (4.7mm * 63mm)
Overall depth from finished floor surface:
1 3/4" (45mm).
2" (5pmm)
2" (50mm)
2" (50mm)
2 1/2" (63mm)
3 1/2" (90mm)
Spacing between blades is not to exceed 3/16" (4.7mm). Such as model BA-2 by Bolar.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel. Coat all surfaces in contact with masonry with two coats of
bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 1,16 and a cleaning efficiency of 49%, percentage of opening shall be 62% [BA-2: 1/8" * 1" (3mm * 25mm)]
9) The deformation under lateral charge is not to exceed 15 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface. [BA-2: 1/8" * 1" (3mm * 25mm)]
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges, (if
required). Verify that all latches are in a closed position and properly greased, (if required).
15
Printing >>>
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch:
All sections of grille will be supplied with hinges and lock notch. The hinges and lock notch will be fabricated in stainless steel and installed on the
grille by the manufacturer. They will be attached to the frame by the general contractor and verified by the architect prior to final approbation.
Option #2: Hinges and lock notch with GB-46 lock downs:
All sections of grilles will be supplied with a combination hinges/lock notch and lock downs model GB-46. The hinges and lock notch will be
fabricated in stainless steel and installed on the grille by the manufacturer. The lock downs will be fabricated of galvanized steel and Teflon, they
will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for easy of operation (one per
vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general contractor. We suggest they be
greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces (one
per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible
accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section: 12482
buyline: 8254
16
Printing >>>
BA-3/4 Foot grilles:
1) To supply and install to location and sizes Bolar foot grilles manufactured under a proven quality system model BA-3/4 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 730 Newton applied over a 4 square inch (100mm) surface in order
to obtain a 1/180" deflection over a 4'-0" (1220 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. For sections larger than 6'-0 * 8'-0 (2000mm * 2400mm) a mechanical joint is to be provided, (if specified).
OR
The perimeter frames shall be " L " shaped such as model "AD" by Bolar, for existing openings. For sections larger than 6'-0 * 8'-0 (1828mm x
2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. For sections larger than 6'-0 *
8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified). A silicone joint is to be applied between the frame and the finished
floor to prevent any water infiltration (by others).
5) Blades shall be "T" shaped, size: 3/8" * 1/8" * 3/4" (9.5mm * 3mm * 19mm). Spacing between blades is not to exceed 3/16" (4.7mm). Such as
model BA-3/4 by Bolar. Overall depth: 1 3/4" (45mm) from finished floor.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel. Coat all surfaces in contact with masonry with two coats of
bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 1,22 and a cleaning efficiency of 49 %, percentage of opening shall be 40%.
9) The deformation under lateral charge is not to exceed 8 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges (if
required). Verify that all latches are in a closed position and properly greased (if required).
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch: [Not available for this model]
Option #2: Hinges and lock notch with GB-46 lock downs: [Not available for this model]
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
17
Printing >>>
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces (one
per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible
accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section: 12482
buyline: 8254
18
Printing >>>
BC-6 Foot grilles:
1) To supply and install to location and sizes Bolar Isomat manufactured under a proven quality system model BC-6 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
3) All aluminum components shall be extruded aluminum alloy 6063-T5
4) Deflection under live load:
The Isomat BC-6 shall be so conceived so as to accept a minimum uniform load of 120 Newton applied over a 4 inch square (100mm) surface in
order to obtain a 1/180" deflection over a 2'-0" (610mm) span.
5) The perimeter frames shall be "˚ " inverted such as model "WW" by Bolar, for anchoring in concrete.
OR
The perimeter frames shall be " Î " such as model "WWI" by Bolar, for anchoring in concrete.
OR
The mat will be supplied with a "SSA" type frame by Bolar. Consisting of an anti-slip aluminum extrusion with beveled edge, attached to the mat
on two surfaces.
6) The blades of the matting are assembled with carpet insertion from the V-Floor Scraper series. The blades are joined together by a flexible vinyl
hinge which allows the matting to be rolled during maintenance handling. Option #1 is available on request at every 300 mm (12" in.) to allow water
to drip into the drain when necessary. This protects the mat well or the floor finish from scratches and suppresses noise when people walk across the matting.
Color chart is:
2714: gray
2725: turquoise
2780: brown
2715: charcoal gray2860: burgundy
Designed for a vestibule with medium traffic, easy to care and especially economical.
7) Spacing between blades and vinyl hinge shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will be
manufactured in sections so as to increase ease of maintenance.
8) The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
9) The sections shall have a friction coefficient of 0,92 and a cleaning efficiency of 76 %, percentage of opening shall be 10 %
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The Isomat BC-6 sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square
and level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. Protect grilles
from construction traffic.
ACCESSORIES / OPTIONS
Option #1: Water run off
The vinyl hinges are notched every 300mm (12") in order to allow water to flow under the mat and into the pit area.
section: 12482
buyline: 8254
19
Printing >>>
BC-1 or BC-7 Foot grilles:
1) To supply and install to location and sizes Bolar foot grilles manufactured under a proven quality system model BC-1 or BC-7 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6063-T5
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 980 Newton applied over a 4 inch square (100mm) in order to
obtain a 1/180" deflection over a 4'-0" (1220 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. Supplied
with sound gasket. For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. Supplied with sound gasket. For sections larger than
6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. Supplied with sound gasket.
For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified). A silicone joint is to be applied between
the frame and the finished floor to prevent any water infiltration (by others).
5) Blades shall be "T" shaped size 1 5/16" * 1/8" * 1 1/2" (35mm * 3mm * 38mm) with a carpet insertion locked at each end. Overall depth from
finished floor surface 2 1/2" (65mm). Spacing between blades is not to exceed 3/16" (4.7mm). Such as model BC-1 or BC-7 by Bolar. Color to be
determined by architect from available carpet models and colors available from manufacturer.
Foot grilles model BC-1: Carpet serie: Interface or Mannington pileless
Foot grilles model BC-7: Carpet serie: V-Floor
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel. Coat all surfaces in contact with masonry with two coats of bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 0,92 and a cleaning efficiency of 77 %, percentage of opening shall be 9 %.
9) The deformation under lateral charge is not to exceed 8 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges (if
required). Verify that all latches are in a closed position and properly greased (if required).
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch:
All sections of grille will be supplied with hinges and lock notch. The hinges and lock notch will be fabricated in stainless steel and installed on the
grille by the manufacturer. They will be attached to the frame by the general contractor and verified by the architect prior to final approbation.
Option #2: Hinges and lock notch with GB-46 lock downs:
All sections of grilles will be supplied with a combination hinges/lock notch and lock downs model GB-46. The hinges and lock notch will be
fabricated in stainless steel and installed on the grille by the manufacturer. The lock downs will be fabricated of galvanized steel and Teflon, they
will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for easy of operation (one per
vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general contractor. We suggest they be
greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
20
Printing >>>
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces (one
per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible
accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section: 12482
buyline: 8254
21
Printing >>>
BC-2 Isomat:
1) To supply and install to location and sizes Bolar Isomat manufactured under a proven quality system model BC-2 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
3) All aluminum components shall be extruded aluminum alloy 6063-T5
4) Deflection under live load:
The Isomat shall be so conceived so as to accept a minimum uniform load of 120 Newton applied over a 4 inch square (100mm) surface in order
to obtain a 1/180" deflection over a 2'-0" (610mm) span.
5) The perimeter frames shall be "˚ " inverted such as model "WW" by Bolar, for anchoring in concrete.
OR
The perimeter frames shall be " Î " such as model "WWI" by Bolar, for anchoring in concrete.
OR
The mat will be supplied with a "SSA" type frame by Bolar. Consisting of an anti-slip aluminum extrusion with beveled edge, attached to the mat
on two surfaces.
6) Blades shall be size 1 5/16" * 1/2" (35mm * 13mm) with carpet inserts locked at each end. Overall depth from finished floor surface 1/2" (13mm).
Spacing between blades is not to exceed 3/16" (4.7mm). Blades are to be assembled together with a noise suppressing vinyl hinge. Such as model
BC-2 by Bolar. Color to be determined by architect from available carpet models and colors available from Mannington or Interface suppliers.
7) Spacing between blades and vinyl hinge shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will be
manufactured in sections so as to increase ease of maintenance.
8) The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
9) The sections shall have a friction coefficient of 0,92 and a cleaning efficiency of 76 %, percentage of opening shall be 10 %
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
3) The Isomat sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
4) All frames are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. Protect grilles
from construction traffic.
ACCESSORIES / OPTIONS
Option #1: Water run off
The vinyl hinges are notched every 300mm (12") in order to allow water to flow under the mat and into the pit area.
section: 12482
buyline: 8254
22
Printing >>>
BCH-4 Foot grilles:
1) To supply and install to location and sizes Bolar foot grilles manufactured under a proven quality system model BCH-4 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 1760 Newton applied over a 4 inch square (100mm) in order to
obtain a 1/180" deflection over a 4'-0" (1220 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. Supplied
with sound gasket. For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. Supplied with sound gasket. For sections larger than
6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. Supplied with sound gasket.
For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified). A silicone joint is to be applied between
the frame and the finished floor to prevent any water infiltration (by others).
5) Blades shall be "T" shaped size 1 5/16" * 1/8" * 1 1/2" (35mm * 3mm * 38mm) with a carpet insertion locked at each end. Overall depth from
finished floor surface 2 1/2" (65mm). Combined with "Y" shaped blades size 11/16" * 1/8" * 1 1/2" (19mm * 3mm * 38mm) with an anti-slip
polymer C9065 insertion of Durometer 90/65, 1/4" (6.4mm) thick locked in at each end. Spacing between blades is not to exceed 3/16" (4.7mm).
Such as model BCH-4 by Bolar. Color to be determined by architect from available carpet models and colors such as distributed by Interface Palette
Plus Solids 2000 __________ and polymer colors as indicated in Bolar literature.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel. Coat all surfaces in contact with masonry with two coats of
bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 1,21 and a cleaning efficiency of 71 %, percentage of opening shall be 18 %.
9) The deformation under lateral charge is not to exceed 8 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges (if
required). Verify that all latches are in a closed position and properly greased (if required).
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch:
All sections of grille will be supplied with hinges and lock notch. The hinges and lock notch will be fabricated in stainless steel and installed on the
grille by the manufacturer. They will be attached to the frame by the general contractor and verified by the architect prior to final approbation.
Option #2: Hinges and lock notch with GB-46 lock downs:
All sections of grilles will be supplied with a combination hinges/lock notch and lock downs model GB-46. The hinges and lock notch will be
fabricated in stainless steel and installed on the grille by the manufacturer. The lock downs will be fabricated of galvanized steel and Teflon, they
will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for easy of operation (one per
23
Printing >>>
vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general contractor. We suggest they be
greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces (one
per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible
accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section: 12482
buyline: 8254
24
Printing >>>
BLA-1 Foot grilles:
1) To supply and install to location and sizes Bolar foot grilles manufactured under a proven quality system model BLA-1 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 980 Newton applied over a 4 inch square (100mm) in order to
obtain a 1/180" deflection over a 4'-0" (1220 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. Supplied
with sound gasket. For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. Supplied with sound gasket. For sections larger than
6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. Supplied with sound gasket.
For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified). A silicone joint is to be applied between
the frame and the finished floor to prevent any water infiltration (by others).
5) Blades shall be "T" shaped size 1 5/16" * 1/8" * 1 1/2" (35mm * 3mm * 38mm). Overall depth from finished floor surface 2 1/2" (65mm). Spacing
between blades is not to exceed 3/16" (4.7mm). Such as model BLA-1 by Bolar.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel. Coat all surfaces in contact with masonry with two coats of
bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 0,92 and a cleaning efficiency of 77 %, percentage of opening shall be 9 %.
9) The deformation under lateral charge is not to exceed 8 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges (if
required). Verify that all latches are in a closed position and properly greased (if required).
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch:
All sections of grille will be supplied with hinges and lock notch. The hinges and lock notch will be fabricated in stainless steel and installed on the
grille by the manufacturer. They will be attached to the frame by the general contractor and verified by the architect prior to final approbation.
Option #2: Hinges and lock notch with GB-46 lock downs:
All sections of grilles will be supplied with a combination hinges/lock notch and lock downs model GB-46. The hinges and lock notch will be
fabricated in stainless steel and installed on the grille by the manufacturer. The lock downs will be fabricated of galvanized steel and Teflon, they
will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for easy of operation (one per
vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general contractor. We suggest they be
greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
25
Printing >>>
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces (one
per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section: 12482
buyline: 8254
26
Printing >>>
BSA-1 Foot grilles:
1) To supply and install to location and sizes Bolar foot grilles manufactured under a proven quality system model BSA-1 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 2260 Newton applied over a 4 square inch (100mm) surface in
order to obtain a 1/180" deflection over a 2'-0" (610 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. Supplied
with sound gasket. For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. Supplied with sound gasket. For sections larger than
6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. Supplied with sound gasket.
For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified). A silicone joint is to be applied between
the frame and the finished floor to prevent any water infiltration (by others).
5) Blades shall be "T" shaped, size: 3/8" * 1/8" * 1" (9.5mm * 3mm * 25mm) striated at every 3/8" (9.5mm). The notch shall be 9/64" (3.2mm) in
width by 3/16" (4.7mm). Spacing between blades is not to exceed 3/16" (4.7mm). Such as model BSA-1 by Bolar. Overall depth: 2" (50mm) from
finished floor.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauges stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauges galvanized steel, no drain. Coat all surfaces in contact with masonry with two
coats of bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 0,94 and a cleaning efficiency of 69 %, percentage of opening shall be 53%
9) The deformation under lateral charge is not to exceed 8 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. The foot-grille sections will be
installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and level with finished floor so as to
permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well supported on all their lengths in
order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges (if
required). Verify that all latches are in a closed position and properly greased, (if required)
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch:
All sections of grille will be supplied with hinges and lock notch. The hinges and lock notch will be fabricated in stainless steel and installed on the
grille by the manufacturer. They will be attached to the frame by the general contractor and verified by the architect prior to final approbation.
Option #2: Hinges and lock notch with GB-46 lock downs:
All sections of grilles will be supplied with a combination hinges/lock notch and lock downs model GB-46. The hinges and lock notch will be
fabricated in stainless steel and installed on the grille by the manufacturer. The lock downs will be fabricated of galvanized steel and Teflon, they
will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for easy of operation (one per
27
Printing >>>
vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general contractor. We suggest they be
greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surface (one
per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible
accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section: 12482
buyline: 8254
28
Printing >>>
BSA-1-3 Foot grilles:
1) To supply and install to location and sizes Bolar foot grilles manufactured under a proven quality system model BSA-1-3 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 2270 Newton applied over a 4 square inch (100mm) surface in
order to obtain a 1/180" deflection over a 2'-0" (610 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. Supplied
with sound gasket. For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. Supplied with sound gasket. For sections larger than
6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. Supplied with sound gasket.
For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified). A silicone joint is to be applied between
the frame and the finished floor to prevent any water infiltration (by others).
5) Blades shall be "T" shaped, size: 3/16" * 1/8" * 1" (4.7mm * 3mm * 25mm) striated at every 3/8" ( 9.5mm). The notch shall be 9/64" (3.2mm)
in width by 3/16" (4.7mm). Spacing between blades is not to exceed 3/16" (4.7mm). Such as model BSA-1-3 by Bolar. Overall depth: 2" (50mm)
from finished floor.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel, no drain. Coat all surfaces in contact with masonry with two coats
of bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 1,19 and a cleaning efficiency of 57 %, percentage of opening shall be 58%
9) The deformation under lateral charge is not to exceed 10 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. The foot-grille sections will be
installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and level with finished floor so as to
permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well supported on all their lengths in
order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges (if
required). Verify that all latches are in a closed position and properly greased (if required).
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch:
All sections of grille will be supplied with hinges and lock notch. The hinges and lock notch will be fabricated in stainless steel and installed on the
grille by the manufacturer. They will be attached to the frame by the general contractor and verified by the architect prior to final approbation.
Option #2: Hinges and lock notch with GB-46 lock downs:
All sections of grilles will be supplied with a combination hinges/lock notch and lock downs model GB-46. The hinges and lock notch will be
fabricated in stainless steel and installed on the grille by the manufacturer. The lock downs will be fabricated of galvanized steel and Teflon, they
will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for easy of operation (one per
29
Printing >>>
vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general contractor. We suggest they be
greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces
(one per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section: 12482
buyline: 8254
30
Printing >>>
BC-5 Isomat:
1) To supply and install to location and sizes Bolar Isomat manufactured under a proven quality system model BC-5 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6063-T5
Dimensions:
Blades " A " carpet inserts 35 mm X 13 mm ( 15/16" X 1/2" )
Blades " B " aluminum 27 mm X 13 mm ( 1 1/16" X 1/2" )
3) Deflection under live load:
The Isomat BC-5 shall be so conceived so as to accept a minimum uniform load of 120 Newton applied over a 4 inch square (100mm) surface in
order to obtain a 1/180" deflection over a 2'-0" (610mm) span.
4) The perimeter frames shall be "˚ " inverted such as model "WW" by Bolar, for anchoring in concrete.
OR
The perimeter frames shall be " Î " such as model "WWI" by Bolar, for anchoring in concrete.
OR
The mat will be supplied with a "SSA" type frame by Bolar. Consisting of an anti-slip aluminum extrusion with beveled edge, attached to the mat
on two surfaces.
5) The blades of the matting are assembled in a regular pattern: a type "A" blade is followed by a type "B" blade and so on. The type "A" blade is
grooved and made from aluminum alloy 6063-T5 with a carpet insertion from the V-Floor Scraper series. The grooves ensure that is slip resistant.
The blades are joined together by a flexible vinyl hinge wich allows the matting to be rolled during maintenance handling. Option #1 is available
on request to clip the vinyl link every 300 mm (12 in.) to allow water to drip into the drain when necessary. This link protects the mat well or the
floor finish from scratches and suppresses noise when people walk across the matting.
Color chart :
2714: gray
2725: turquoise
2780: brown
2715:charcoal gray
2860: burgundy
Designed for a vestibule with medium traffic, easy to care for, classic and, above all, especially very economical.
6) Spacing between blades and vinyl hinge shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will be
manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 0,92 and a cleaning efficiency of 76 %, percentage of opening shall be 10 %
9) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
10) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The Isomat sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. Protect grilles
from construction traffic.
ACCESSORIES / OPTIONS
Option #1: Water run off
The vinyl hinges are notched every 300mm (12") in order to allow water to flow under the mat and into the pit area.
section: 12482
buyline: 8254
31
Printing >>>
BSA-4 Foot grilles:
1) To supply and install to location and sizes Bolar foot grilles manufactured under a proven quality system model BSA-4 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 3110 Newton applied over a 4 square inch (100mm) surface in
order to obtain a 1/180" deflection over a 2'-0" (610 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. Supplied
with sound gasket. For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. Supplied with sound gasket. For sections larger than
6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. Supplied with sound gasket.
For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified). A silicone joint is to be applied between
the frame and the finished floor to prevent any water infiltration (by others).
5) Blades shall be "T" shaped, size: 3/8" * 1/8" * 1" (9.5mm * 3mm * 25mm) striated at every 7/8" (22mm). The notch shall be 9/64" (3.2mm) in
width by 3/16" (4.7mm). Spacing between blades is not to exceed 3/16" (4.7mm). Such as model BSA-4 by Bolar. Overall depth: 2" (50mm) from
finished floor.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel, no drain. Coat all surfaces in contact with masonry with two coats
of bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 1,10 and a cleaning efficiency of 59 %, percentage of opening shall be 40%
9) The deformation under lateral charge is not to exceed 9 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. The foot-grille sections will be
installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and level with finished floor so as to
permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well supported on all their lengths in
order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges (if
required). Verify that all latches are in a closed position and properly greased, (if required)
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch:
All sections of grille will be supplied with hinges and lock notch. The hinges and lock notch will be fabricated in stainless steel and installed on the
grille by the manufacturer. They will be attached to the frame by the general contractor and verified by the architect prior to final approbation.
Option #2: Hinges and lock notch with GB-46 lock downs:
All sections of grilles will be supplied with a combination hinges/lock notch and lock downs model GB-46. The hinges and lock notch will be
fabricated in stainless steel and installed on the grille by the manufacturer. The lock downs will be fabricated of galvanized steel and Teflon, they
will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for easy of operation (one per
32
Printing >>>
vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general contractor. We suggest they be
greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces (one
per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section: 12482
buyline: 8254
33
Printing >>>
BSV-1 Foot grilles:
1) To supply and install to location and sizes Bolar foot grilles manufactured under a proven quality system model BSV-1 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 2540 Newton applied over a 4 square inch (100mm) surface in
order to obtain a 1/180" deflection over a 4'-0" (1220 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. For sections larger than 6'-0 * 8'-0 (1828mm x
2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. For sections larger than 6'-0 *
8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified). A silicone joint is to be applied between the frame and the finished
floor to prevent any water infiltration (by others).
5) Blades shall be "Y" shaped size 11/16" * 1/8" * 1 1/2" (19mm * 3mm * 38mm). With an anti-slip insertion of Durometer 90 vinyl 1/4" ( 6.4mm
) thick, striated for a multidirectional anti-slip effect and locked in at each end. Overall depth from finished floor surface 2 1/2" (65mm). Spacing
between blades is not to exceed 3/16" (4.7mm). Such as model BSV-1 by Bolar. Color to be determined at your choise: black, grey, beige or brown.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel. Coat all surfaces in contact with masonry with two coats of
bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 1,00 and a cleaning efficiency of 47%, percentage of opening shall be 27%
9) The deformation under lateral charge is not to exceed 13 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges,
(if required). Verify that all latches are in a closed position and properly greased, (if required).
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch:
All sections of grille will be supplied with hinges and lock notch. The hinges and lock notch will be fabricated in stainless steel and installed on the
grille by the manufacturer. They will be attached to the frame by the general contractor and verified by the architect prior to final approbation.
Option #2: Hinges and lock notch with GB-46 lock downs:
All sections of grilles will be supplied with a combination hinges/lock notch and lock downs model GB-46. The hinges and lock notch will be
fabricated in stainless steel and installed on the grille by the manufacturer. The lock downs will be fabricated of galvanized steel and Teflon, they
will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for easy of operation (one per
vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general contractor. We suggest they be
greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
34
Printing >>>
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces (one
per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible
accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section: 12482
buyline: 8254
35
Printing >>>
BSV-2 Isomat:
1) To supply and install to location and sizes Bolar Isomat manufactured under a proven quality system model: BSV-2 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6063-T5
3) Deflection under live load:
The Isomat BSV-2 shall be so conceived so as to accept a minimum uniform load of 120 Newton applied over a 4 inch square (100mm) surface in
order to obtain a 1/180" deflection over a 2'-0" (610mm) span.
4) The perimeter frames shall be "˚ " inverted such as model "WW" by Bolar, for anchoring in concrete.
OR
The perimeter frames shall be " Î " such as model "WWI" by Bolar, for anchoring in concrete.
OR
The mat will be supplied with a "SSA" type frame by Bolar. Consisting of an anti-slip aluminum extrusion with beveled edge, attached to the mat
on two surfaces.
5) Blades shall be size 1 5/16" * 1/2" (35mm * 13mm). With an anti-slip insertion of Durometer 90 vinyl 3/16" (4.7mm) thick, striated for a
multidirectional anti-slip effect and locked in at each end. Blades are to be assembled together with a noise suppressing vinyl hinge. Overall depth
from finished floor surface 1/2" (13mm). Spacing between blades is not to exceed 3/16" (4.7mm). Such as model BSV-2 by Bolar. Color to be
determined at your choise: black, grey, beige or brown.
6) Spacing between blades and vinyl hinge shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will be
manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 0,78 and a cleaning efficiency of 40 %, percentage of opening shall be 10 %
9) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
10) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The Isomat BSV-2 sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square
and level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. Protect grilles
from construction traffic.
ACCESSORIES / OPTIONS
Option #1: Water run off
The vinyl hinges are notched every 300mm (12") in order to allow water to flow under the mat and into the pit area.
section: 12482
buyline: 8254
36
Printing >>>
BSV-3 Foot grilles:
1) To supply and install to location and sizes Bolar foot grilles manufactured under a proven quality system model: BSV-3 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 980 Newton applied over a 4 inch square (100mm) surface in order
to obtain a 1/180" deflection over a 4'-0" (1220 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. Supplied
with sound gasket. For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. Supplied with sound gasket. For sections larger than
6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. Supplied with sound gasket.
For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified). A silicone joint is to be applied between
the frame and the finished floor to prevent any water infiltration (by others).
5) Blades shall be "T" shaped size 1 5/16" * 1/8" * 1 1/2" (35mm * 3mm * 38mm) with an anti-slip insertion of Durometer 90 vinyl 3/16" (4.7mm)
thick, striated for a multidirectional anti-slip effect and locked in at each end. Overall depth from finished floor surface 2 1/2" (65mm). Spacing
between blades is not to exceed 3/16" (4.7mm). Such as model BSV-3 by Bolar. Color to be determined at your choise: black, grey, beige or brown.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel. Coat all surfaces in contact with masonry with two coats of
bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 0,82 and a cleaning efficiency of 38 %, percentage of opening shall be 9%.
9) The deformation under lateral charge is not to exceed 8 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges (if
required). Verify that all latches are in a closed position and properly greased (if required).
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch:
All sections of grille will be supplied with hinges and lock notch. The hinges and lock notch will be fabricated in stainless steel and installed on the
grille by the manufacturer. They will be attached to the frame by the general contractor and verified by the architect prior to final approbation.
Option #2: Hinges and lock notch with GB-46 lock downs:
All sections of grilles will be supplied with a combination hinges/lock notch and lock downs model GB-46. The hinges and lock notch will be
fabricated in stainless steel and installed on the grille by the manufacturer. The lock downs will be fabricated of galvanized steel and Teflon, they
will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for easy of operation (one per
vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general contractor. We suggest they be
greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
37
Printing >>>
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surface
(one per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section: 12482
buyline: 8254
38
Printing >>>
BV-1 Foot grilles:
1) To supply and install to location and sizes Bolar foot grilles manufactured under a proven quality system model: BV-1 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 2540 Newton applied over a 4 inch square (100mm) surface in
order to obtain a 1/180" deflection over a 4'-0" (1220 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. For sections larger than 6'-0 * 8'-0 (1828mm x
2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. For sections larger than 6'-0 *
8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified). A silicone joint is to be applied between the frame and the finished
floor to prevent any water infiltration (by others).
5) Blades shall be "Y" shaped size 11/16" * 1/8" * 1 1/2" (19mm * 3mm * 38mm) with an anti-slip insertion of Durometer 90 vinyl 1/4" (6.4mm)
thick locked in at each end. Overall depth from finished floor surface 2 1/2" (65mm). Spacing between blades is not to exceed 3/16" (4.7mm). Such
as model BV-1 by Bolar. Color to be determined at your choise: black, grey, beige or brown.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel. Coat all surfaces in contact with masonry with two coats of
bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 1,00 and a cleaning efficiency of 47 %, percentage of opening shall be 27%
9) The deformation under lateral charge is not to exceed 13 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges, (if
required). Verify that all latches are in a closed position and properly greased, (if required).
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch:
All sections of grille will be supplied with hinges and lock notch. The hinges and lock notch will be fabricated in stainless steel and installed on the
grille by the manufacturer. They will be attached to the frame by the general contractor and verified by the architect prior to final approbation.
Option #2: Hinges and lock notch with GB-46 lock downs:
All sections of grilles will be supplied with a combination hinges/lock notch and lock downs model GB-46. The hinges and lock notch will be
fabricated in stainless steel and installed on the grille by the manufacturer. The lock downs will be fabricated of galvanized steel and Teflon, they
will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for easy of operation (one per
vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general contractor. We suggest they be
greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
39
Printing >>>
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces
(one per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section: 12482
buyline: 8254
40
Printing >>>
BSP-90 Foot grilles:
1) To supply and install to location and sizes Bolar foot grilles manufactured under a proven quality system model BSP-90 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All components shall be extruded of PVC ( duro vinyl 90)
3) Deflection under live load:
The foot grilles model BSP-90 shall be so conceived so as to accept a minimum uniform load of 1280 Newton applied over a 4 square inch (100mm)
surface in order to obtain a 1/180" deflection over a 2'-0" (610 mm) span.
The perimeter frames shall be "L" shaped such as model "AD" inversed in PVC ( duro vinyl 90) by Bolar, for existing openings.
4) Dimentions: 19 mm X 6,4 mm X 32 mm ( 3/4" X 1/4" x 1 1/4")
The bars or our model BSP-90 are assembly with P.V.C” holding rods and are 12,5 mm (1/2") of external diameter in a P.V.C. ring permitting a
permanent and regular space between each others (recommend space is 9,5 mm (3,8")
Standard colors are white or Turquoise. Other colors available upon conditional request.
5) Spacing 3/8 (9,5 mm) between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity.
Foot grille will be manufactured in sections so as to increase ease of maintenance.
6) The frames will be supplied in lenght pre cut for assembly on job site.
7) The sections shall have a friction coefficient of 0,76 and a cleaning efficiency of 69 %, percentage of opening shall be 32%
8) The deformation under lateral charge is not to exceed 13 (visual) after application of a maximal charge of 1280 Newton (288 pounds) at a 45
degree angle in relation to the surface.
9) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot grille model BSP-90 sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot
grilles, square and level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to
be level and well supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges (if
required). Verify that all latches are in a closed position and properly greased, (if required)
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch:
All sections of grille will be supplied with hinges and lock notch. The hinges and lock notch will be fabricated in stainless steel and installed on the
grille by the manufacturer. They will be attached to the frame by the general contractor and verified by the architect prior to final approbation.
Option #2: Hinges and lock notch with GB-46 lock downs:
All sections of grilles will be supplied with a combination hinges/lock notch and lock downs model GB-46. The hinges and lock notch will be
fabricated in stainless steel and installed on the grille by the manufacturer. The lock downs will be fabricated of galvanized steel and Teflon, they
will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for easy of operation (one per
vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general contractor. We suggest they be
greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
41
Printing >>>
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces
(one per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section: 12482
buyline: 8254
42
Printing >>>
BV-2 Isomat:
1) To supply and install to location and sizes Bolar Isomat manufactured under a proven quality system model: BV-2 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6063-T5
3) Deflection under live load:
The Isomat BV-2 shall be so conceived so as to accept a minimum uniform load of 120 Newton applied over a 4 inch square (100mm) surface in
order to obtain a 1/180" deflection over a 2'-0" (610mm) span.
4) The perimeter frames shall be "˚ " inverted shaped such as model "WW" by Bolar, for anchoring in concrete.
OR
The perimeter frames shall be " Î " such as model "WWI" by Bolar, for anchoring in concrete.
OR
The mat will be supplied with a "SSA" type frame by Bolar. Consisting of an anti-slip aluminum extrusion with beveled edge, attached to the mat
on two surfaces.
5) Blades shall be size 1 5/16" * 1/2" (35mm * 13mm). With an anti-slip insertion of Durometer 90 vinyl 3/16" (4.7mm) thick and locked in at each
end. Blades are to be assembled together with a noise suppressing vinyl hinge. Overall depth from finished floor surface 1/2" (13mm). Spacing
between blades is not to exceed 3/16" (4.7mm). Such as model BV-2 by Bolar. Color to be determined at your choise: black, grey, beige or brown.
6) Spacing between blades and vinyl hinge shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will be
manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 0,78 and a cleaning efficiency of 41 %, percentage of opening shall be 10 %.
9) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
10) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The Isomat BV-2 sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square
and level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. Protect grilles
from construction traffic.
ACCESSORIES / OPTIONS
Option #1: Water run off
The vinyl hinges are notched every 300mm (12") in order to allow water to flow under the mat and into the pit area.
section: 12482
buyline: 8254
43
Printing >>>
BV-3 Foot grilles:
1) To supply and install to location and sizes Bolar foot grilles manufactured under a proven quality system model: BV-3 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 980 Newton applied over a 4 inch square (100mm) surface in order
to obtain a 1/180" deflection over a 4'-0" (1220 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. Supplied
with sound gasket. For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. Supplied with sound gasket. For sections larger than
6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. Supplied with sound gasket.
For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided (if specified). A silicone joint is to be applied between
the frame and the finished floor to prevent any water infiltration (by others).
5) Blades shall be "T" shaped size 1 5/16" * 1/8" * 1 1/2" (35mm * 3mm * 38mm) with an anti-slip insertion of Durometer 90 vinyl 3/16" (4.7mm)
thick locked in at each end. Overall depth from finished floor surface 2 1/2" (65mm). Spacing between blades is not to exceed 3/16" (4.7mm). Such
as model BV-3 by Bolar. Color to be determined at your choise: black, grey, beige or brown.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel. Coat all surfaces in contact with masonry with two coats of
bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 0,78 and a cleaning efficiency of 40 %, percentage of opening shall be 9%
9) The deformation under lateral charge is not to exceed 8 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic.
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch:
All sections of grille will be supplied with hinges and lock notch. The hinges and lock notch will be fabricated in stainless steel and installed on the
grille by the manufacturer. They will be attached to the frame by the general contractor and verified by the architect prior to final approbation.
Option #2: Hinges and lock notch with GB-46 lock downs:
All sections of grilles will be supplied with a combination hinges/lock notch and lock downs model GB-46. The hinges and lock notch will be
fabricated in stainless steel and installed on the grille by the manufacturer. The lock downs will be fabricated of galvanized steel and Teflon, they
will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for easy of operation (one per
vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general contractor. We suggest they be
greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
44
Printing >>>
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces
(one per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section:12482
buyline: 7350
45
Printing >>>
Foot grilles Signature Series:
SIGNATURE SERIES
At least, customized entrances!
We can now apply to your aluminum foot grilles systems:
1) Your company name
2) Your logo
3) Your signature
4) Your address
5) Your phone number
6) Your products and services … anything you can imagine!
But how? Our highly sophisticated software allows us to reproduce, with the use of a digitizer, the data required for your choise of inscription, which
will entrance the appearance of the grille in your lobby or in any other area.
This advanced technology can be applied on several models like: BA-1, BA-125, BA-1-3, BA-12, BA-3/4 .
Maximum height is 36" ( 904 mm ) and there is practically no limit on length.
section: 12482
buyline: 8254
46
Printing >>>
CO33 Foot grilles:
1) To supply and install to location and sizes foot grilles manufactured under a proven quality system model: CO33 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 1240 Newton applied over a 4" (100mm) square surface in order
to obtain a 1/180" deflection over a 4'-0" (1220 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. For
sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. For sections larger than 6'-0 * 8'-0 (1828mm x
2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. For sections larger than 6'-0 *
8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified). A silicone joint is to be applied between the frame and the finished
floor to prevent any water infiltration (by others).
5) Blades (A) shall be "T" shaped, size: 3/8" * 1/8" * 1" (9.5mm * 3mm * 25mm).
Blades (B) shall be "T" shaped, size: 3/8" * 1/8" * 1" (9.5mm * 3mm * 25mm) striated at every 3/8" (9.5mm). The notch shall be 9/64" (3.2mm)
in width by 3/16" (4.7mm).
Spacing between blades is not to exceed 3/16" (4.7mm). Such as model CO33 by Bolar. Overall depth: 2" (50mm) from finished floor.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel. Coat all surfaces in contact with masonry with two coats of
bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 1,10 and a cleaning efficiency of 59 %, percentage of opening shall be 45%.
9) The deformation under lateral charge is not to exceed 9,5 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges (if
required). Verify that all latches are in a closed position and properly greased (if required).
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch:
All sections of grille will be supplied with hinges and lock notch. The hinges and lock notch will be fabricated in stainless steel and installed on the
grille by the manufacturer. They will be attached to the frame by the general contractor and verified by the architect prior to final approbation.
Option #2: Hinges and lock notch with GB-46 lock downs:
All sections of grilles will be supplied with a combination hinges/lock notch and lock downs model GB-46. The hinges and lock notch will be
fabricated in stainless steel and installed on the grille by the manufacturer. The lock downs will be fabricated of galvanized steel and Teflon, they
47
Printing >>>
will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for easy of operation (one per
vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general contractor. We suggest they be
greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces (one
per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section:12482
buyline: 7350
48
Printing >>>
CO234 Foot grilles:
1) To supply and install to location and sizes foot grilles manufactured under a proven quality system model: CO234 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 2420 Newton applied over a 4" (100mm) square surface in order
to obtain a 1/180" deflection over a 4'-0" (1220 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. For
sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. For sections larger than 6'-0 * 8'-0 (1828mm x
2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. For sections larger than 6'-0 *
8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified). A silicone joint is to be applied between the frame and the finished
floor to prevent any water infiltration (by others).
5) Blades (A) shall be "T" shaped, size: 3/8" * 1/8" * 2" (9.5mm * 3mm * 50mm).
Blades (B) shall be "T" shaped, size: 3/8" * 1/8" * 2" (9.5mm * 3mm * 50mm) striated at every 7/8" (22mm). The notch shall be 9/64" (3.2mm) in
width by 3/16" (4.7mm).
Spacing between blades is not to exceed 3/16" (4.7mm). Such as model CO234 by Bolar. Overall depth: 2" (50mm) from finished floor.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel. Coat all surfaces in contact with masonry with two coats of
bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 1,18 and a cleaning efficiency of 53 %, percentage of opening shall be 38%.
9) The deformation under lateral charge is not to exceed 10 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges (if
required). Verify that all latches are in a closed position and properly greased (if required).
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch: (not available for this model )
Option #2: Hinges and lock notch with GB-46 lock downs: (not available for this model )
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
49
Printing >>>
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installations are to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces (one
per vestibule).
NOTE: They will not be incorporated to each section’s in order to minimize unauthorized manipulations of grilles, and thus prevent possible accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section:12482
buyline: 7350
50
Printing >>>
CO34 Foot grilles:
1) To supply and install to location and sizes foot grilles manufactured under a proven quality system model: CO34 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 1400 Newton applied over a 4" (100mm) square surface in order
to obtain a 1/180" deflection over a 4'-0" (1220 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. For
sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. For sections larger than 6'-0 * 8'-0 (1828mm x
2438mm) a mechanical joint is to be provided (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. For sections larger than 6'-0 *
8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified). A silicone joint is to be applied between the frame and the finished
floor to prevent any water infiltration (by others).
5) Blades (A) shall be "T" shaped, size: 3/8" * 1/8" * 1" (9.5mm * 3mm * 25mm).
Blades (B) shall be "T" shaped, size: 3/8" * 1/8" * 1" (9.5mm * 3mm * 25mm) striated at every 7/8" (22mm). The notch shall be 9/64" (3.2mm) in
width by 3/16" (4.7mm).
Spacing between blades is not to exceed 3/16" (4.7mm). Such as model CO34 by Bolar. Overall depth: 2" (50mm) from finished floor.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel. Coat all surfaces in contact with masonry with two coats of
bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 1,18 and a cleaning efficiency of 53 %, percentage of opening shall be 38%.
9) The deformation under lateral charge is not to exceed 10 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges (if
required). Verify that all latches are in a closed position and properly greased (if required).
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch:
All sections of grille will be supplied with hinges and lock notch. The hinges and lock notch will be fabricated in stainless steel and installed on the
grille by the manufacturer. They will be attached to the frame by the general contractor and verified by the architect prior to final approbation.
Option #2: Hinges and lock notch with GB-46 lock downs:
All sections of grilles will be supplied with a combination hinges/lock notch and lock downs model GB-46. The hinges and lock notch will be
fabricated in stainless steel and installed on the grille by the manufacturer. The lock downs will be fabricated of galvanized steel and Teflon, they
51
Printing >>>
will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for easy of operation (one per
vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general contractor. We suggest they be
greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces
(one per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible
accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
section:12482
buyline: 7350
52
Printing >>>
CO40 Foot grilles:
1) To supply and install to location and sizes Bolar foot grilles manufactured under a proven quality system model: CO40 as manufactured by:
Bolar Canada Inc.
50 Omer de Serres
Blainville, Québec
J7C 5H2
Tel: 450-435-7385 OR 1-800-552-6527
Fax: 450-435-3600 OR 1-800-667-3660
2) All aluminum components shall be extruded aluminum alloy 6061-T6
3) Deflection under live load:
The foot grilles shall be so conceived so as to accept a minimum uniform load of 1500 Newton applied over a 4 square inch (100mm) surface in
order to obtain a 1/180" deflection over a 4'-0" (1220 mm) span.
4) The perimeter frames shall be an inverted "T" shape such as model "VV" by Bolar, in order to anchor the structure into the concrete. For sections larger than 6'-0 * 8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified).
OR
The perimeter frames shall be "L" shaped such as model "AD" by Bolar, for existing openings. For sections larger than 6'-0 * 8'-0 (1828mm x
2438mm) a mechanical joint is to be provided, (if specified).
OR
The perimeter frames shall be "Z" shaped such as model "TT" by Bolar. For installation over finished floor surfaces. For sections larger than 6'-0 *
8'-0 (1828mm x 2438mm) a mechanical joint is to be provided, (if specified). A silicone joint is to be applied between the frame and the finished
floor to prevent any water infiltration (by others).
5) Blades (A) shall be "T" shaped, size: 3/16" * 1/8" * 1" (4.7mm * 3mm * 25mm).
Blades (B) shall be "T" shaped, size: 3/8" * 1/8" * 1" (9.5mm * 3mm * 25mm) striated at every 7/8" (22mm). The notch shall be 9/64" (3.2mm) in
width by 3/16" (4.7mm).
Spacing between blades is not to exceed 3/16" (4.7mm). Such as model CO40 by Bolar. Overall depth: 2" (50mm) from finished floor.
6) Spacing between blades and retaining rods shall be so as to meet manufacturer's specifications for the minimum weight capacity. Foot grille will
be manufactured in sections so as to increase ease of maintenance.
7) The frames will be supplied with a pan. Pan shall be of 22 gauge stainless steel, no drain.
OR
The frames will be supplied with a pan. Pan shall be of 22 gauge galvanized steel. Coat all surfaces in contact with masonry with two coats of
bituminous paint.
OR
The frames will be supplied without a pan. A coat of waterproofing is to be applied to the concrete base to avoid water infiltration (by others).
8) The sections shall have a friction coefficient of 1,15 and a cleaning efficiency of 55 %, percentage of opening shall be 48%.
9) The deformation under lateral charge is not to exceed 11,5 (visual) after application of a maximal charge of 6130 Newton (1380 pounds) at a 45
degree angle in relation to the surface.
10) All sections shall be in accordance with ASTM B117 norms, and be able to sustain a 1000 hours salt fog without any notable changes.
11) Manufacturer shall be able to confirm this data and be able to supply architect with all necessary reports and shop drawings.
Installation:
1) The foot-grille sections will be installed in their frames, as a last item, to prevent damages during construction. Install all foot grilles, square and
level with finished floor so as to permit easy manipulation of all sections. All frame members and intermediary supports are to be level and well
supported on all their lengths in order to avoid any deflection over a long term period.
2) All frames and pans are to be thoroughly cleaned before installing any grille section in order for them not to exceed finished floor level. All sound
gaskets damaged during installation, are to be replaced before final inspection. Protect grilles from construction traffic. Install all hinges,
(if required). Verify that all latches are in a closed position, and properly greased (if required).
ACCESSORIES/OPTIONS
Option #1: Hinges and lock notch:
All sections of grille will be supplied with hinges and lock notch. The hinges and lock notch will be fabricated in stainless steel and installed on the
grille by the manufacturer. They will be attached to the frame by the general contractor and verified by the architect prior to final approbation.
Option #2: Hinges and lock notch with GB-46 lock downs:
All sections of grilles will be supplied with a combination hinges/lock notch and lock downs model GB-46. The hinges and lock notch will be
fabricated in stainless steel and installed on the grille by the manufacturer. The lock downs will be fabricated of galvanized steel and Teflon, they
53
Printing >>>
will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for easy of operation (one per
vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general contractor. We suggest they be
greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #3: Lock downs GB-46 (4 per grilles):
All sections of grille will be supplied with a lock downs mechanism GB-46 (4 per sections of grille). The lock downs will be fabricated of
galvanized stele and Teflon, they will be attached to the grille sections by the manufacturer. The lock downs will be supplied with a special key for
easy of operation (one per vestibule). All lock downs have to be greased (BSRS 2000 water resistant)) at the time of installation by the general
contractor. We suggest they be greased at least 4 times a year. All systems are to be verified by the architect prior to final approbation.
Option #4: Plates and screws:
Installed by the manufacturer at each sections corner, they must be attached to the frame by the general contractor using the screws supplied by the
manufacturer. Installation to be verified by the architect prior to final approbation.
Option #5: Lifting hooks:
All grilles will be supplied with lifting hooks in order to provide easy lifting of sections without efforts or risk of damaging the grille surfaces (one
per vestibule).
NOTE: They will not be incorporated to each sections in order to minimize unauthorized manipulations of grilles, and thus prevent possible
accidents.
Option #6: Sound gasket:
All frame sections will be supplied with a sound gasket, as per manufacturer's specifications. The sound gasket's function will be to buffer noise and
vibrations that could occur between frames and blades.
54
Printing >>>
CLEANING PROCEDURES
To maintain the quality of the product and increase it's durability for a great number of years we suggest you apply the following procedures
General:
1- The cleaning of the frames and pans should be done twice a week during the winter season and by-monthly at all other times.
2- Each time you clean your frames and pans, make sure there are no residue or particles between the frame members and the grilles themselves. If
this step is not taken, the grates could suffer permanent damage over time.
3- If the units are attached to a drain you should ensure that nothing is blocking the water flow to the drain.
4- The grilles must be cleaned of all debris witch could be stuck between the blades in order to keep all parts straight and properly working.
5- NEVER APPLY WAX or other polishing products to the surface of the grilles, this would create a high risk area on which people would trip and
could badly hurt themselves.
SPECIFICS:
6- All aluminum models should be cleaned with a soapy solution and left to dry.
7- All aluminum surfaced grilles should be cleaned with a mild soap solution and wiped dry.
8- All abrasive surfaced grilles should be freed of all debris with a small plastic scraper and cleaned with a mild soap solution, then left to dry.
9- All models with a carpet insertion will have to be cleaned according to the carpet manufacturer's recommendations such as described in pages
******
Options:
10- When cleaning all grates, the hinges and lock mechanism should be inspected to ensure that all parts are properly attached to the frame and
are functioning properly. All latches should be inspected and greased with water resistant grease such as BSRS 2000. Any unit not functioning
properly should be replaced to avoid further problems.
55
Printing >>>
INTERFACE, FLOORING SYSTEMS CANADA
GENERAL MAINTENANCE GUIDE
OCTOBER 1990
INTRODUCTION
The major purpose of the XYZ Company carpet tile maintenance program is to preserve, as nearly as practical, the original beauty and appearance
of the carpet and to prolong its useful life. Your maintenance program thus assists in optimizing the investment in the carpet tile system.
This program confines the majority of maintenance efforts to the areas needing the most attention. Typical trouble spots are those track-off areas
that collect foot soil tracked in from outdoors or from hard surface floors indoors. Also requiring attention are funnel areas where foot traffic is
squeezed through concentrated
areas such as doorways, stairwells and in front of drinking fountains.
This program recommends preventive measures, cleaning equipment and compatible general cleaning agents, as well as cleaning agents for stain
and spot removal for the various substances to which the carpet may be exposed. The program establishes cleaning frequencies on a daily, weekly,
monthly or longer cycle basis for types of cleaning systems applicable to specific areas of the building.
PREVENTIVE MAINTENANCE
The most effective element in a building maintenance program is proper attention to the preventive measures that are available to the building owner.
Successful restraints begin with careful selection of track-off systems used in entryways and with the prevention of tracking wax, dirt and other
foreign matter from other floor surfaces into transitional areas.
To reduce interior maintenance costs, soil should be kept out of the building and off the carpet. Preventive maintenance measures could include the
use of Interface soil-trapping Foyer Tiles in entryways and track-off areas, protective coverings for floors in certain areas and strict rules for
confining or eliminating sources of such risks.
Another preventive measure facilitated by the free-lay carpet tile is a planned system of rotation of tiles to minimize the effect of traffic patterns.
VACUUM CLEANING AND PILE LIFTING
1) VACUUMING
Machines with cylinder brushes or brush and beater-bar combinations should be used. The vacuum equipment must be set so that brushes are in
contact with the pile surface. Twin motor machines with independent motors for suction and brushing are preferred for this task. Unless power heads
are used, canister type machines are generally not recommended.
Vacuum cleaning not only removes soil from the carpet, but also lifts and restores the pile. Areas to be vacuumed should be divided into three
separate groups: heavy, medium and light traffic areas.
Heavy traffic areas such as lobbies, entryways and areas subject to immediate off-the-street traffic should be vacuumed daily or twice daily,
depending on weather conditions. Often, the need for vacuuming can be determined by visual inspection. Frequent vacuuming in heavy traffic areas
will eliminate much of the soil and prevent it from tracking onto other areas, thereby reducing vacuuming time in other areas.
Light traffic areas usually require vacuuming once or twice weekly.
2) PILE LIFTING:
At least once a week in heavily used areas, a pile-lifter should be used to "open up" the pile and remove buried soil. A pile-lifter should also be used
to precondition carpet for general cleaning. The pile-lifter is also valuable for lifting crushed pile in heavy traffic areas and for loosening caked-on
solids such as mud and food. For best results, the machine should be applied against the lay of the pile.
Where the maintenance schedule calls for pile lifting, it may substitute for vacuuming.
TILE REPLACEMENT AND ROTATION:
Some carpet tiles may become so badly stained or damaged to the point that normal cleaning methods are inadequate. These may be replaced from
shelf stock. A tile is removed from the floor by slipping a knife under one corner and peeling the tile from the floor.
Care must be taken when installing the replacement tile to ensure that the tile direction of existing tiles is matched by the replacement tile. Arrows
on the reverse side of INTERFACE products assist in determining pile directions.
The face pile of the surrounding tiles should be brushed upright and the replacement tile should be fitted carefully to prevent pile fibers from
becoming trapped between tile joints.
A carpet tile taken from shelf stock will have a newer appearance than the one being replaced. Normally, the newness will disappear within a
matter of weeks. But should the new tile stand out in sharp contrast to the surrounding tiles in a highly visible area, the owner will find it desirable
to shuffle several tiles a "musical chair" fashion. The new tile goes into a less visible area, while the tiles that have aged with use are placed in the
56
Printing >>>
more visible area.
Rotation of tiles in heavy traffic areas should be managed in much the same way as replacements. Tiles are moved from no traffic to moderate
traffic areas. Tiles subjected to heavy traffic should not be exchanged with tiles that are new or that have received few traffic.
Shelf stock must be worked into the rotational plan so that it ages with the rest of the carpet.
For optimum results, tile rotation needs to be planned in conjunction with and always prior to a general cleaning. The cleaning process helps blend
in the disturbed areas. The specifications for such a rotational program will be dependent on the study of actual carpet usage and resulting traffic
patterns. The rotational plan requires a high degree of discipline. The implementation of such a plan is recommended only if management is
committed to this concept for prolonging the useful life of the carpet. Such commitment must extend to providing adequate staff.
CLEANING CHEMICALS
In any maintenance program, care must be taken in choosing cleaning chemicals. Cleaning chemicals should fall in the range of 4 pH to 8 pH, but
preferably as close to neutral as possible.
Spotting chemicals will, of necessity, be of high pH value, but these must be used sparingly and should be flushed out with plain water after the spot
has been treated.
In addition, cleaning chemicals should be tested for sticky residues which promote re-soiling. As a test, evaporate a chemical solution in a flat dish.
If the residue is dry and flaky or powder, it may be used. Do not use detergents that evaporate to a sticky residue, as these will stick to carpet fibers.
Extraction cleaning chemicals should not contain silicone defoamers. These defoamers, if used, should be poured directly into the recovery tank.
SPOT CLEANING:
Effective soil removal procedures are an integral part of the program. Special attention is given to high-risk sources of spills and stains such as
washroom and vending areas with coffee machines.
Spots and stains are easily removed, if dealt with immediately. Spills only become stains when allowed to dry; therefore, it is essential to deal with
spills promptly. When a spot is identifiable, an appropriate stain remover may be selected.
Removal of unidentifiable stains require a careful approach. If the stain is dry, brush the area with a stiff bristle brush to remove the excess solids.
Then, using water and a soft, absorbent cloth, gently agitate the pile surface, working from the outer edge of the stain to its center. Blot the area dry
and check for effectiveness of stain removal.
Repeat if necessary.
If the stain persists, repeat the process using a mild detergent solution. If the stain is still evident, proceed to the use of a proven dry cleaning fluid,
also applied with a soft, white absorbent cloth. Never pour a solvent directly onto a carpet tile; permanent damage to the backing structure will result.
When using solvents, make sure the area is well-ventilated and prohibit any smoking.
INTERFACE strongly recommends using a hot-water extractor to remove residues from the treated areas, after spot removal has been completed.
In addition to a regular spot removal program, INTERFACE suggests that the program include removal activities prior to carpet cleaning.
Spot cleaning chemicals required:
1) Acid-based for coffee, tea, soft drinks, etc.
2) Solvents for tar, grease, oil, etc.
3) Chewing gum remover for chewing gum. Use as directed.
4) Normal traffic lane pre-sprayer, for most foods, traffic soiling, water-based stains, etc.
Remember, flush out all treated spots with the hot water extraction method.
If obtaining safe cleaning chemicals is difficult, check the IMAG range.
HOT WATER EXTRACTION
1) Vacuum and pre-spot before cleaning.
2) Use traffic lane pre-spray sparingly.
3) Apply minimum amounts of cleaning solution by moving applicator swiftly and evenly across surface.
4) Be sure that at least 75% of cleaning fluid is recovered.
5) Mix chemicals carefully, AND DO NOT EXCEED CONCENTRATION RECOMMENDED BY CHEMICAL MANUFACTURER.
Mostly, extraction systems tend to lift the pile surface. However, if it is determined that the pile is becoming compacted, than the carpet should be
pile lifted after cleaning and after it becomes dry.
Rotary cleaning is not a preferred method of cleaning. It is, however, effective when the following procedures are followed:
1) Vacuum before cleaning, then pre-spot.
2) Clean, using recommended chemicals and traffic sprays in strengths recommended by chemical manufacturers.
3) Pile lift after cleaning.
4) Every 4th cleaning or so, depending on residue build-up, substitute an extraction system and proceed as per the directions outlined under
"Hot Water Extraction".
57
Printing >>>
DRY FOAM EXTRACTION
Dry foam cleaning is not a preferred method. It is effective when the following procedures are followed:
1) Use only reel type machines - not rotary.
2) Vacuum before cleaning, then pre-spot.
3) Clean using recommended chemicals and traffic sprays in strengths recommended by chemical manufacturers.
4) Pile lift after cleaning.
5) Approximately every 4th cleaning, substitute and extraction system and proceed as per directions outlined under "Hot Water Extraction."
DRY POWDER
Use of the HOST system is recommended, using the following procedures:
1) Vacuum and pre-spot.
2) Spread powder per manufacturer's instructions. THERMALLY PIGMENTED YARNS (solution dyeing)
In our quest for ultimate performance, INTERFACE offers a complete range of products manufactured with Thermally Pigmented yarns. These
fibershave incredible fastness properties and can withstand cleaning by very aggressive chemical substances.
STAIN REMOVAL PROCEDURE:
1) If the spill is still wet, carefully blot until no trace of the stain is found on the toweling. Extraction with a wet vacuum or extraction unit is best.
2) Apply a neutral or acid pH detergent directly to the spot, being careful not to overwet and spread the stain. Gently massage the fibers, working
from the outer edge towards the center of the stain. Allow the detergent to work approximately one minute, than blot until no trace of the stain is
found on the toweling.
3) Repeat step 2 until no trace of the stain will transfer onto the toweling.
4) Apply white vinegar to the stain if any remains and allow to work a few minutes, than blot well.
5) If any stain remains, saturate the stain with 100% household bleach (5.25%) and let stand for 30 minutes to one hour, or until the stain is removed,
whichever occurs first.
6) Rinse with clean water at least three times, blotting well after each rinsing, again, if extraction is available, this is preferred.
If you have any questions concerning the above procedure, please
contact your Interface representative.
FREQUENCY CHART
AREA
Foyer
Entrances
Lobbies
Elevators
Corridors
Areas Adjacent
To Hard Surfaces
General traffic
Lanes
Work stations
Mail and copier
Rooms
Private offices
Cafeterias
General traffic lanes
VACUUMING
Daily
Daily
Daily
Daily
Daily
Daily
SPOTTING
Daily
Daily
Daily
Daily
Daily
Daily
CLEANING
weekly
weekly
Weekly
Weekly
BI-Weekly
Weekly
Daily
Daily
BI-Weekly
Daily
Daily
Weekly
Daily
BI-monthly
BI-monthly
Twice weekly
Daily or As required
Daily
Weekly
As Required
Daily
BI-monthly
after each shift
BI-weekly
58
Printing >>>
BOLAR FOOT GRILLES
FILE: CRIQ 645-4706
CRIQ TECHNICAL REPORT PRT-85-117
CRIQ TECHNICAL REPORT PRT-89-052
1985
1989
F.C. 5528
GRILLAGE BOLAR (CANADA) INC.
50, Omer de Serres
Blainville, Quebec J7C 5H2
Tel: (514) 435-7385
Fax: (514) 435-3600
To the attention of Mr. Andre Lazure
PROJECT MANAGER
Michel Massicotte, Eng.
Task force of performing
tests for Products Division
SUMMARY
The customer GRILLAGE Bolar Inc. anxious to know more about the physical characteristics of its product (foot grille) has called upon the CRIQ
(Quebec Industrial Research Center).
Following this request, the CRIQ has evaluated 30 foot grilles on six (6) different tests. See reports PRT-85-117 and PRT-89-052.
The results of these tests have shown that:
-For the same grille, the friction coefficient varies from one type of shoe to the other. As for the grille, the principal variation is noted on the vinyl
covered grille which, when wet offers a better friction coefficient than the aluminum or the carpet.
-The percentage of opening varies from 9% to 62%.
-The deflection under live load varies from one grille to the other and, of course, from one span to the other. Apart from models BC-2,BV-2,BSV2 , the charges vary from 730 to 4610 Newton.
-The distortion under lateral charge shows that certain grilles have been badly damaged whereas others were only slightly damaged. The residual
distortion, as well as the plastic energy deformation are proportional to the damages caused by the charge.
-The salt fog test fog has made the aluminum dull on the top of the grilles while the sides were spotted. The carpet and vinyl have not shown
noticeable changes.
PRT-85-117
PRT-89-052
1.0 DESCRIPTION OF THE PROJECT
Further to the tests effected in the laboratories of the CRIQ, this technical report is a description of the method used for the testing of the product,
the results as a whole and the appropriate conclusions and recommendations.
2.0 AIM OF THE PROJECT
The aim of the project was to make the evaluation of 30 foot grilles following six (6) tests so as to supply technical and/or comparative data from
one model of grille to the other.
3.0 DESCRIPTION OF THE METHODS AND ANALYSIS OF THE RESULTS
The tests have been effectuated on 30 different grilles described in section 3.1 following six (6) tests for which the analysis and results are described
in sections 3.2 to 3.7 inclusively.
3.1. FRICTION COEFFICIENT
59
Printing >>>
We define the friction coefficient between two (2) surfaces the same way as we define the traction parallel to the surface applying the weight on the
top of the grille. Also, we obtain the static friction coefficient when the surfaces are not in motion and the dynamic friction coefficient for surfaces
when in motion. The set-up for the testing has been realized with a Rockford Machine Tool model FR 6-06-32-11 at the CRIQ's workshop at
Ste-Foy. To five (5) surfaces of the shoes were mounted on the machine tool with a weight of 50 pounds (22,7 kg). The shoe was laid down on the
grille, which was fixed to the movable part of the machine tool moving at approximately 3 centimeters per second.
The recording of the friction strength was obtained by a load cell connected to a tracing table. The testing periods were for 20 seconds and
repeated three times. Tests were performed for the 30 grilles in parallel and perpendicular directions to the bars of the grilles for five (5) different
types of surfaces on dry and wet grilles. The letters used in the charts are corresponding to the following shoes:
-A:
-B:
-C:
-D:
-E:
shoe with a checkered sole
working boot
jogging running shoe
ankle boot with a hard rubber sole
rubber surface
The results of the tests have shown that for the shoes utilized, no coefficient of static friction has been obtained.
This is probably due to the fact that the ungluing of the sole occurs progressively and not in a block.
Furthermore, it was noted that there was a high variation of the friction, the minimum being from 0,30 and the maximum from 2,1. We have also
noted that some factors were influencing this coefficient. First, the type of sole makes the friction coefficient variable. In decreasing order, we find
the shoe with a checkered sole (a), rubber surface (e), jogging shoe (c), working boot (b) and the ankle foot (d), when the grilles were dry. When
the grilles were wet, the soles (c) and (e) had practically the same values.
Secondly, the results have shown that the orientation of the sole on the grille, either perpendicular of parallel to the bars, was sometimes influencing the
friction coefficient. In the case of the dry grille with aluminum top, the coefficient is higher when the sole is parallel to the bars. In the other cases,
the results have shown that the orientation of the sole on the grille was sometimes influencing one way and sometimes the other way.
Thirdly, the type of surface was influencing the friction coefficient. To better discern it, the chart 5 indicates the average friction coefficients for
aluminum, vinyl and carpet. We note that for the dry surfaces, the three coefficients are near 1,0, however, when the surfaces are wet all the friction
coefficients are reducing but not in the same proportions. In fact, the aluminum surfaces have a weaker friction coefficient, whereas the vinyl
remains the highest.
3.2. PERCENTAGE OF OPENING
The percentage of opening has been evaluated for each of the 30 grilles from the width of the bars and the spacing. In the case of the BSA-1 grille
bearing #2, the percentage of opening includes the spacing between the bars and the grooves made with a saw.
In the case of the grilles covered with carpet, we have established that the percentage of opening is the spacing between the bars, serving as holder
for the carpet. The percentage of the variable obtained is 9% for the carpet grille #6 and 62% for the grilles #3 and #8, model BA-2.
3.3. CLEANING EFFICIENCY
The aim of this test was to compare the cleaning efficiency of the different grilles. Following a research of standards and unable to find one, we
have defined our own method. The set-up used is similar to the one used for the friction coefficient. The working boot with a load of 50 pounds is
supported by the tool-holder of the filing-vice ROCKFORD MACHINE TOOL model FR 6-06-32-11. The grille is fixed at the movable part of the
machine tool.
The clean boot was weighed and an even coat of clay of 100 gr. was applied to the sole. More specifically, a preparation of 3190.0 grams of 40 F
Siam clay mixed with 500 ml of water. Then the boot was again weighed. After the second weighing, the boot with the load of 50 pounds was set
on the grille and pulled on a length of 42,5 cm (the hook holding the boot at 5,0 cm above the grille). Finally, the boot was weighed for the third
time, this enabled us to calculate the mass of clay which was removed.
The formula used was as follows:
% of cleaning = boot after cleaning - clean boot
-------------------------------- X 100
boot before cleaning - clean boot
This gives us the (%) percentage of clay removed during the cleaning period. The results compiled inside chart #1 of annex A are based on three
tests. The pictures #4 to #22 indicate the set-up used and the clay left by the footprints on the grilles.
The results obtained during the tests have demonstrated that for the aluminum grilles, the percentage of cleaning was always very close to 50%
except for the grille BSA-1, which was 69%. The vinyl surfaces have shown a percentage of cleaning of 47%, a value very close to the aluminum
grilles.
Finally, the grilles covered with carpet have obtained the highest percentage of cleaning with 76% and 77%.
These high values are due to the fact that the fibber of the carpet removed the clay located in the grooves of the sole, which could not be obtained
with the other grilles. However, these carpet grilles are not conceived for this kind of use, which reflects a very severe utilization.
3.4 DEFLECTION UNDER LIVE LOAD
60
Printing >>>
The aim of this test was to obtain a deflection of 1/180 of the span on the different grilles. The tests have been realized for a span of 24 inches (610
mm) and 32 inches (810 mm). The values obtained for a span of 48 inches (1220 mm) have been extrapolated from the first two. The test has been
made with an MTS hydraulic machine. The load has been applied at the center of the span with a 4 inchs square surface. We note that to obtain
comparative results, it would be necessary to retake a same square surface of 4 inches on the side. The registration of the load in term of the
deflection was made by the MTS machine and is shown at annex C "GRAPHIC RESULTS".
We find at the beginning of the curve, an area with a very weak slope. It corresponds to the deflection due to the position of the grille on its
supports and if it is the case, it does flatten the carpet. The second portion of the curve is linear and the slope of the curve is stiffer and corresponds
to the rigidity of the grille. After obtaining the maximum load, the curve comes down a little to the right of the first curve to come back to its
original point. The calculation of the necessary load for a deflection of 1/180 of the span is made from the slopes measured on the curves. We reject
then the additional deflections corresponding to the position of the grille and the flatness of the carpet to consider only the deflection of the grille.
The method of calculation and the results are found at annex B "Calculation of Deflections under live load".
3.5 DISTORTION UNDER LATERAL LOAD
The application of a load or of a great impact on the surface of a grille entails undesirable permanent distortion. The aim of this test is to compare
the different models of the grilles submitted to a heavy lateral load.
To carry out the tests, the following method was used:
-The grille was leaning on its two side supports.
-A maximum load of 6130 Newton (1380 pounds) was then applied at 45 degrees with respect to the surface of the grille, at the center of two rods.
-The load was applied by means of one (1) inch square steel bar of high tensile strength.
-The load was applied slowly and a load curve, corresponding to the distortion, has been obtained for each grille.
The results obtained from the graphics and from a subjective evaluation of four (4) people are found at chart 7 "Distortion under lateral charge". We
find the residual plastic energetic distortion of the grille as well as the subjective results of evaluation. At the time of the objective evaluation, grilles
number 2, 6, 7, 10, 12 & 13 have been considered as being more damaged, while grille #3 has been considered as being the one with less damages.
3.6 SALT FOG
The Salt Fog test has been realized on six samples of grilles supplied by the customer, as per standard ASTM B117 for a period of 1000 hours.
Following the period of 1000 hours, the main observations are as follows:
-For the aluminum, the top of the grilles became dull, while the sides and the underneath were spotted.
-For the carpet, the salt fog had no noticeable effect. The rivets, used to hold the carpet in the aluminum grooves, have not undergone any
noticeable changes.
-For the vinyl, the salt fog had no noticeable effect. However, the screws that were holding it have rusted.
The photographs of the samples taken before and after the test of the salt fog will be found at annex E, under 33 to 44.
4.0 CONCLUSION AND RECOMMENDATIONS
Following the six (6) tests realized on the 30 different models of grilles, we have reached the following conclusions:
From the six tests, one is unable to say that one model of grille is better than the other. One must consider each test and take into consideration the
importance that it represents for the user, thus for industrial use, one will have advantage to use a grille resisting to lateral charges with a high live
load, whereas for commercial use, one will have advantage to consider the cleaning efficiency.
The tests results will help the user of grilles to make a more judicious choice.
61
Printing >>>
CHARTS AND DATA'S
CHART A
SHOES IDENTIFICATION
62
Printing >>>
CHART B
CHART OF MODEL IDENTIFICATION
63
Printing >>>
CHART II
PHYSICAL CHARACTERISTICS
- The results are pulled from Technical report PRT-85-117 and PRT-89-052
64
Printing >>>
CHART V
AVERAGES OF FRICTION COEFFICIENTS, AS PER TYPE OF SURFACE
CHART VI
DEFLEXION UNDER LIVE LOAD
*These values are corresponding to lives loads in Newton, to obtain same in pounds, divide by 4,448.
65
Printing >>>
CHART VII
DISTORTION UNDER LIVE LOAD
4: irréparable
8: reparable but badly damaged
12 : reparable but damaged
16: slightly damaged
20 : not obviously affected
66
Printing >>>
TABLE OF RESULTS
67
Printing >>>
ROOF HATCH
& SMOKE HATCH
ROOF HATCH
SPECIFICATIONS: BOLAR MODEL “G”
1. The BOLAR model “G” is entirely fabricated of 16GA (2.5 mm) galvanized steel as per standard ASTM A653 and covered with a coat of prime paint.
2. We suggest that the maximum size for one cover hatch BOLAR model “G” does not exceed 3’-6 X 10’-0 (1070mm X 340 mm). Over this size
double covers are suggested.
3. The BOLAR model “G” roof hatch is entirely insulated R12 rated, cover and base.
4. The base of the BOLAR roof hatch model “G” is 12” (305mm) high with a 3 _” (90mm) peripheral flange at the bottom, witch serves as a
seating for the hatch. This flange is perforated at the four corners of a 3/8” (9.5mm) hole witch serves to anchor the hatch.
5. The base of the roof hatch model “G” is also equipped with of a flashing at the top. Fabricated of 16 GA (2.5mm) galvanized steel as per
standard ASTM A653.
6. The cover of the roof hatch BOLAR model “G” and the interior insulation liner are fabricated of 16GA (2.5mm) galvanized steel as per standard
ASTM A653. The whole is reinforced so as to receive the hardware and built to cover the whole base and the flashing at the top. It opens at an angle
of 70∞.
7. The BOLAR roof hatch model “G” must always be shipped with sufficient telescopic cylinders to counterbalance the weight of the cover or covers.
Equipped with a minimum of 2 stainless steel hinges with 5/16” (8mm) rods acting as pivots.
Fabricated of steel with one or more hold open operating arms, covered with one coat of yellow zinc, having an easy manageable with one hand
handle, covered with a red vinyl handle for a better grip.
Including a heavy duty lock set with an integrated comdamnation reliable with a steel galvanized cable integreted into the cover to the side
exterior handle. ( no pad lock request)
For the two cover roof hatch model “G” the lockset is replaced by two locksets system, each having a double attachment secured to the base and
also connected to the exterior handle on each cover.
The BOLAR roof hatch model “G” is also equipped with a hollow neoprene seal witch will give a water-air- tightness to the joint of the cover or
covers and at the base of the roof hatch thus creating a water-proof unit.
The BOLAR roof hatch model “G” is guaranteed against all manufacturing defectiveness for a period of 5 years, conditional to a comfortable use.
8. The erection of a BOLAR roof hatch model “G” it must be secured to the framing of the building to an appropriate level to avoid the frame-work
to warp.
9. See options: attached herewith.
68
Printing >>>
ROOF HATCH
SPECIFICATIONS: BOLAR MODEL “A”
1) The BOLAR roof hatch model “A” is entirely fabricated of 11GA (3.2mm) mill finish aluminum for the cover and the base and of 18GA (2mm)
for the cover interior insulation liner.
2) We suggest that the maximum size for one cover for BOLAR model “A” roof hatch does not exceed 3’-0 x 8’-0 (914mm X 2438mm). Over this
size double covers are suggested.
3) The BOLAR roof hatch model “A” is entirely insulated R12 rated, cover and base.
4) The base of the roof hatch, BOLAR model “A” is 12” (305mm) high. It has a peripheral flange of 3 _” (90mm) at the base, which serves as a
seating for the roof hatch. This flange is perforated at the 4 corners of a hole of 3/8” (9.5mm) which serves to anchor the hatch to the roof.
5) The base of the BOLAR roof hatch, model ”A” is equipped with a flashing at the top. All is fabricated of 11GA (3.2mm) mill finish aluminum.
6) The cover of BOLAR roof hatch model “A” opens at an angle of 70∞ and is fabricated of mill finish aluminum 11GA (3.2mm) and the interior
insulation liner of the cover is in 18GA (2mm). All is reinforced where necessary to receive hardware. It is built to cover the whole base and the
flashing at the top.
7) The BOLAR roof hatch model “A” must always be shipped with sufficient telescopic cylinders to counterbalance the weight of the cover or covers.
A minimum of 2 stainless steel hinges with 5/16” (8mm) rods serving as pivots.
Fabricated of steel with one or more hold open operating arms, covered with a coat of yellow zinc, having an easy manageable with one hand
handle, covered with a red vinyl handle for a better grip.
The BOLAR roof hatch model “A” is also equipped with a hollow neoprene seal, which assures a water-air-tightness to the joint of the cover or covers and to the base of the hatch, forming a weatherproof unit.
BOLAR roof hatch model “A” is guaranteed against all manufacturing defectiveness for a period of 5 years, conditional to a comfortable use.
8) The erection of BOLAR roof hatch model “A” it must be secured to the framing of the building to an appropriate level to avoid the frame-work
to warp.
9) See options: attached herewith.
69
Printing >>>
ROOF HATCH
SPECIFICATIONS: BOLAR MODEL “AG”
1. The BOLAR roof hatch model “AG” is fabricated of mill finish 11GA (3.2mm) aluminum for the cover and in 18GA (2mm) mill finish aluminum
for the cover insulation liner.. The base of the roof hatch is fabricated of 16GA (2.5mm) galvanized steel, as per standard ASTM A653 and is
covered with one coat of prime paint.
2. The maximum size for one cover for BOLAR model “AG” is practically without limits. However, we suggest that over 6'-0 x 20'-0 (1800mm X
6100mm) double covers should be used.
3. BOLAR roof hatch model “AG” is entirely insulated R12 rated, cover and base.
4. The base of the BOLAR roof hatch model “AG” has a peripheral flange of 3 _” (90mm) at the bottom, which serves as a seating for the roof
hatch. This flange is perforated at the four corners for a hole of 3/8” (9.5mm) which serves to anchor the hatch to the roof.
5. The base of the BOLAR roof hatch model “AG” is also equipped with a flashing at the top. All is fabricated of 16GA (2.5mm) galvanized steel,
as per standard ASTM A653.
6. The cover for BOLAR roof hatch model “AG” opens at an angle of 70∞. It is fabricated of 11GA (3.2mm) mill finish aluminum and the interior insulation liner of the cover of 18GA (2mm). All is reinforced where necessary to receive hardware and is built to cover the entire base and the
flashing at the top.
7. The BOLAR roof hatch model “AG” must always be shipped with sufficient telescopic cylinders to counterbalance the weight of the cover (covers).
A minimum of 2 stainless steel hinges with rods of 5/16” (8mm) serving as pivots.
Fabricated of steel with hold open operating arms and covered with one coat of yellow zinc. Also having a manageable handle with one hand
covered with a red vinyl handle for a better grip.
BOLAR roof hatch model “AG” is also equipped with a hollow neoprene seal, which assures a water-air- tightness to the joint of the cover or
covers and to the base of the hatch, forming a weatherproof unit.
BOLAR roof hatch model “AG” is guaranteed against manufacturing defectiveness for a period of 5 years, conditional to a comfortable use.
8. The erection of a BOLAR roof hatch model “AG” it must be secured to the framing of the building to an appropriate level to avoid the framework to warp.
9. See options herewith.
70
Printing >>>
ROOF HATCH
SPECIFICATIONS:BOLAR MODEL "GR "
1. The BOLAR roof hatch model “GR” is entirely fabricated of 16 GA (1.8mm) galvanized steel, as per standard ASTM A653 and covered with a
coat of prime paint.
2. We suggest that the maximum size for one cover of BOLAR model “GR” does not exceed 3’-6 X 10’-0 (1070mm X 304mm). Over this size
double covers are suggested.
3. BOLAR model “GR” roof hatch is entirely insulated R12 rated, cover & base.
4. The base for BOLAR model “GR” roof hatch is 12” (305mm) high, no peripheric flange at the bottom. The base is perforated at the four corners
for a hole of 3/8” (9.5mm) witch serves to anchor the roof hatch to the interior of the chimney.
5. The base of the BOLAR roof hatch model “GR” is also equipped with a flashing at the top. All in 16GA (2.5mm) galvanized steel, as per
standard ASTM A653.
6. The cover of the BOLAR roof hatch model “GR” and the interior liner are fabricated of 16GA (2.5mm) galvanized steel, as per standard ASTM
A653. All is reinforced where necessary to receive the hardware and built to cover the whole base and the flashing at the top. It opens at an angle
of 90∞.
7. The BOLAR roof hatch model “GR” must always be shipped with telescopic cylinders in sufficient quantities to counterbalance the weight of
the cover (covers).
A minimum of 2 stainless steel hinges with 5/16” (8mm) rods serving as pivots.
Fabricated of steel with one or more hold open operating arms and covered with a coat of yellow zinc. Also having an easy manageable one hand
handle covered with red vinyl handle for a better grip.
Heavy duty lockset with an integrated comdamnation reliable with a steel galvanised cable integreted into the cover to the side exterior handle.
( no pad lock request )
For the two cover roof hatch model “GR” the sets of locks are replaced by two lockset system, each having a double attachment secured to the base
and connected to the exterior handle with a galvanised cable.
The BOLAR roof hatch model “GR” is also equipped with a hollow neoprene seal, which assures a water-air-tightness to the joint of the cover or
covers and to the base of the hatch, forming a weatherproof unit.
The BOLAR roof hatch model “GR” is guaranteed against manufacturing defectiveness for a period of 5 years, conditional the a comfortable use.
8. The erection of the BOLAR roof hatch model “GR” it must be secured to the framing of the building to an appropriate level to avoid the
frame-work to warp.
9. See options herewith.
71
Printing >>>
ROOF HATCH
SPECIFICATIONS: BOLAR MODEL “AR”
1. BOLAR roof hatch model “AR” is entirely fabricated of 11GA (3.2mm) mill finish aluminum for the cover and the base and 18GA (2mm) for
the cover interior insulation liner.
2. We suggest that the maximum size for one cover, BOLAR model “AR” does not exceed 3’-0 x 8’-0 (914mm X 2438mm). Over this size double
covers are suggested.
3. BOLAR roof hatch model “AR” is entirely insulated R12 rated for cover and base.
4. The base of the BOLAR model “AR” roof hatch is 12” (305mm) high, it has no peripheral flange at the bottom. The base is perforated at the four
corners for a hole of 3/8 (9.5mm), which serves to anchor the hatch into the chimney.
5. The base of the BOLAR roof hatch model “AR” is equipped with a flange at the top, fabricated of 11GA (3.2mm) mill finish aluminum.
6. The cover of the BOLAR roof hatch model “AR” opens at an angle of 90∞. It is fabricated of 11GA (3.2mm) mill finish aluminum and the
interior insulation liner of the cover of 18GA (2mm). All is reinforced where necessary to receive hardware. It is built to cover the whole base and
the flashing at the top.
7. BOLAR roof hatch model “AR” must always be shipped with sufficient telescopic cylinders to counterbalance the weight of the cover (covers).
A minimum of 2 stainless steel hinges with 5/16" (8mm) rods serving as pivots.
Fabricated of steel with one or more hold open operating arms and covered with one coat of yellow zinc. Also having a manageable handle with
one hand covered with a red vinyl handle for a better grip.
A set of locks including 2 chromium plated handles, one interior and exterior with padlock hasps for the interior and exterior. All in galvanized steel.
For the two cover roof hatch model “AR” the set of locks is replaced by two lockset system, each having a double attachment secured to the base.
The BOLAR roof hatch model “AR” also includes hollow neoprene seal which assures a water-air-tightness to the joint of the cover or covers and
to the base of the hatch, forming a weather-proof unit.
The BOLAR roof hatch model “AR” is guaranteed against manufacturing defectiveness for a period of 5 years, conditional to a comfortable use.
8. The erection of a BOLAR roof hatch model “AR” it must be secured to the framing of the building to an appropriate level to avoid the
frame-work to warp.
9. See options herewith.
72
Printing >>>
ROOF HATCH
SPECIFICATIONS: BOLAR MODEL “AGR”
1. The BOLAR roof hatch model “AGR" is fabricated of 11GA (3.2mm) mill finish aluminum for the cover and 18GA (2mm) mill finish aluminum
for the cover insulation liner. The base of the roof hatch is fabricated of 16GA (2.5mm) galvanized steel as per standard ASTM A653 and covered
with one coat of prime paint.
2. The maximum size for one cover BOLAR model “AGR” is practically without limits. However, we suggest that over 6'’0 X 20'’0 (1800 X
6100mm) double covers should be used.
3. BOLAR model “AGR” roof hatch is entirely insulated R12 rated, cover and base.
4. The base of the roof hatch BOLAR model “AGR” has no peripheral flange at the bottom. The base is perforated at the four corners for a hole of
3/8" (9.5mm) which serves to fix the roof hatch into the chimney.
5. The base of the BOLAR model “AGR” roof hatch is also equipped with a flashing at the top. All is fabricated of 16GA (2.5mm) galvanized steel,
as per standard ASTM A653.
6. The cover of the BOLAR model “AGR” roof hatch opens at 90∞. It is fabricated of 11GA (2.2mm) mill finish aluminum and the interior insulation
liner of the cover of 18GA (2mm). All is reinforced where necessary to receive hardware and built to cover the whole base and its flashing.
7. The BOLAR model “AGR” roof hatch must always be shipped with telescopic cylinders in sufficient quantities to counterbalance the weight of
the cover or covers.
A minimum of 2 stainless steel hinges with 5/16" (8mm) rods serving as pivots.
Fabricated of steel with one or more hold open operating arms covered with one coat of yellow zinc and having a manageable handle with one hand,
covered with a red vinyl handle for a better grip.
A set of locks including 2 chromium plated handles interior and exterior with padlock hasps for interior and exterior. All of galvanized steel.
For the two cover roof hatch model “AGR” the set of locks is replaced by two lockset system each having a double attachment secured to the base.
The BOLAR roof hatch model “AGR” also includes hollow neoprene seal which assures a water-air-tightness to the joint of the cover or covers and
to the base of the hatch, forming a weather-proof unit.
The BOLAR model “AGR” roof hatch is guaranteed against manufacturing defectiveness for a period of 5 years, conditional to a comfortable use.
8. The erection of a BOLAR roof hatch model “AGR” it must be secured to the framing of the building to an appropriate level to avoid the
frame-work to warp.
9. See options herewith.
73
Printing >>>
SMOKE HATCH
SPECIFICATIONS: BOLAR MODEL “SH”
1. The BOLAR smoke hatch model “SH” is entirely fabricated of 16GA (2.5mm) galvanized steel as per standard ASTM A653 and covered with
one coat of prime paint.
2. We suggest that the maximum size for one cover smoke hatch BOLAR model “SH” does not exceed 3’-6 X 10’-0 (1070mm X 3040mm). Over
this size double covers are suggested.
3. The BOLAR smoke hatch model “SH” is entirely insulated R12 rated, cover and base.
4. The base of the BOLAR smoke hatch model “SH” is 12” (305mm) high. It has a peripheral flange of 3_" (90mm) at the bottom, witch serves as
a setting for the hatch. This flange is perforated at the four corners for a hole of 3/8” (9.5mm) witch serves to anchor the hatch to the roof.
5. The base of the BOLAR smoke hatch model “SH” is also equipped with a flashing at the top. All is fabricated of 16GA (2.5mm) galvanized steel,
as per standard ASTM A653.
6. The cover of the BOLAR model “SH” smoke hatch and the interior cover insulation liner are fabricated of 16GA (2.5mm) galvanized steel, as
per standard ASTM A653. All is reinforced where necessary to receive the hardware and built to cover the whole base and the flashing at the top.
It opens at an angle of 70∞.
7. The BOLAR smoke hatch model “SH” must always be shipped with telescopic cylinders in sufficient quantities to counterbalance the weight of
the cover or covers, thus assuring a fast opening in case of emergency.
A minimum of 2 stainless steel hinges with 5/16” (8mm) rods serving as pivots.
Fabricated of steel with one or more hold open operating arms covered with a coat of yellow zinc. Also having an easy manageable with one hand
handle, covered with a red vinyl handle for a better grip.
A set of locks with a strike/latch with integreted comdamnation connected to the exterior handle by a galvanized steel cable and a fusible link ULC
approved, which will operate at 165∞F (74∞C) allowing an immediate opening of the cover or covers (see options for any other system of
strike/latch or locks connected or not to the alarm system).
For the two cover smoke hatch model “AGR” the set of locks is replaced by two lock set system, each having a double attachment secured to the
base. Also connected to the exterior handle by a galvanized cable.
The BOLAR model “SH” smoke hatch is also equipped with a hollow neoprene seal witch provides a water-air-tightness to the joint of the cover
or covers and to the base of the hatch, forming a weather-proof unit.
The BOLAR model “SH” smoke hatch is guaranteed against manufacturing defectiveness for a period of 5 years, conditional to a comfortable use.
8. The erection of the BOLAR smoke hatch model “SH” it must be secured to the framing of the building to an appropriate level to avoid the
frame-work to warp.
9. See options herewith.
ANNEX: AVAILABLE OPTIONS FOR BOLAR ROOF HATCHES AND SMOKE HATCHES
MODELS: “G” – “GR” – “A” – “AG” – “AGR” – “SH”
1. 90∞ cover opening (standard on models: “GR” – “AR” and “AGR” )
2. Anti-theft grille.
3. R30 insulation for food plant.
4. R42 insulation for refrigerated warehouse.
5. Height of the base, other than 12” (305mm).
6. Other gauge for steel or aluminum. (Aluminum not applicable for models “SH “ ).
7. Bolclip system holding paper to the roof hatch or smoke hatch.
8. Opening from the floor level with a manuel winch.
9. Opening from the floor level with an electrical winch.
10. Aluminum steel safety post.
11. Galvanized steel safety post.
11 a.
12. Compression spring cylinders (not advisable).
74
Printing >>>