RANCHO SANTA MARGARITA, CALIFORNIA 92688 STORE #CA
Transcription
RANCHO SANTA MARGARITA, CALIFORNIA 92688 STORE #CA
15974 N. 77th STREET SUITE 100 SCOTTSDALE, AZ 85260 602.277.7877 SHEET INDEX BUILDING SUMMARY 2013 CALIFORNIA BUILDING CODE A0.1 REFERENCE SITE PLAN 2013 CALIFORNIA ELECTRICAL CODE LS1.0 LIFE SAFETY / EXIT A1.0 EXISTING/DEMO PLAN A1.1 DIMENSIONED PLAN A1.2 FLOOR PLAN A1.3 DOOR SCHEDULE A2.0 FINISH PLAN A3.0 REFLECTED CEILING PLAN A-2 A4.0 INTERIOR ELEVATIONS EXISTING BUILDING (V-B) A5.0 DETAILS STORE #CA-1239 A6.0 WALL TYPES / DETAILS A7.0 ENLARGED RESTROOM PLAN / ELEVATIONS K1.0 KITCHEN EQUIPMENT PLAN & SCHEDULE 30451 AVENIDA DE LAS FLORES STE "E" K1.1 KITCHEN ELEVATIONS K1.2 KITCHEN / SEATING DETAILS 1 STORIES (PER TABLE 503) 9,500 (PER TABLE 503) ADA1.0 1 STORY RANCHO SANTA MARGARITA, CALIFORNIA 92688 1,779 SF (PER 2013 CBC TABLE 503) YES (FULLY SPRINKLERED) OCCUPANT LOAD AND EGRESS ANALYSIS USE ASSEMBLY PROJECT DESCRIPTION AREA LOAD FACTOR 1,036 SF 1:15 OCCUPANTS 74 KITCHEN 472 SF 1:200 3 OTHER/OFFIC (BUSINESS) 179 SF 1:100 1 RESTROOMS 92 SF - 1,779 SF NOTE: LOAD FACTORS BASED ON 2013 CBC TABLE 1004.1.2 101 102 103 OCCUPANTS = 32 INCHES = 32 INCHES = 32 INCHES REQUIRED FACTOR 78 .20 NUMBER OF EXITS (PER 2013 CBC TABLE 1021.1) NOTE: MAXIMUM DISTANCE TO AN EXIT WITH SPRINKLER SYSTEM = PLUMBING FIXTURE COUNT ANALYSIS TOTAL SQ. FT. = 1,779 OCCUPANT LOAD FACTOR PER TABLE "A" 2013 CPC. GROUP A2 GROUP B TOTAL OCCUPANT LOAD = 78 FIXTURE COUNT BASED ON TOTAL 50 OCCUPANTS MIMIMUM PLUMBING FACILITIES PER TABLE 422.1 TOTAL OCCUPANTS WATER CLOSETS FIXTURE PER PERSON MALE 50% OF 41 = 20.5 = 21 1: (1 - 50) 2: (51 - 150) 1: (151 - 300) FEMALE 50% OF 41 = 20.5 = 21 1: (1 - 25) 2: (26 - 50) 3: (51 - 100) 4: (101 - 200) URINALS FIXTURE PER PERSON LAVATORIES FIXTURE PER PERSON OTHER FIXTURE PER PERSON 1: (1 - 200) 1: (201 - 300) 1: (301 - 400) 1: (1 - 200) 1: (201 - 400) 1: (401 - 600) 1 SERVICE SINK OR LAUNDRY TRAY 1: (1 - 100) 2: (101 - 200) 4: (201 - 300) 5: (401 - 600) PLUMBING FIXTURES PROVIDED: WATER CLOSETS URINALS LAVATORIES MALE 1 - 1 FEMALE 1 - 1 NOTE: OTHER 1 EXCEPTION: 3a THE TOTAL NUMBER OF REQUIRED WATER CLOSETS FOR FEMALES SHALL BE NOT LESS THAN THE TOTAL NUMBER OF REQUIRED WATER CLOSETS AND URINALS FOR MALES. THE REQUIREMENT SHALL NOT APPLY WHEN SINGLE OCCUPANCY TOILE FACILITIES ARE PROVIDED FOR EACH SEX IN AN "A" OR "E" OCCUPANCY WITH AN OCCUPANT LOAD OF LESS THAN 50. EITHER a. THE REQUIRED URINAL SHALL BE PERMITTED TO BE OMITTED OR b. IF INSTALLED, THE URINAL SHALL NOT REQUIRE A SECOND WATER CLOSET TO BE PROVIDED FOR THE FEMALE. SP1.4 SPECIFICATIONS INSTALLATION OF NEW INTERIOR WALLS, DOORS AND MILLWORK NEW TYPE 1 EXHAUST HOOD WITH FIRE PROTECTION M1.0 MECHANICAL FLOOR PLAN & SCHEDULES M2.0 MECHANICAL ROOF PLAN M3.0 MECHANICAL DETAILS M4.0 MECHANICAL SPECIFICATIONS H1.0 HOOD DRAWINGS H2.0 HOOD DRAWINGS H3.0 HOOD DRAWINGS H4.0 HOOD DRAWINGS PROJECT TEAM ARCHITECT: MICHAEL FRIES FM GROUP INC. 15974 N.77TH ST. SUITE 100 SCOTTSDALE, AZ 85260 P: (480) 397.0046 F: (602) 277.8288 mtfries@fmgroup.net FM GROUP PROJECT MGR. GLEN I ROSS FM GROUP INC. 15974 N.77TH ST. SUITE 100 SCOTTSDALE, AZ 85260 P: (480) 397.0005 F: (602) 277.8288 gross@fmgroup.net ELECTRICAL ENGINEER: OMID ARDEBILI ARDEBILI BORUM ENGINEERS 8100 E. INDIAN SCHOOL RD. STE. 205 SCOTTSDALE, AZ. 85251 P: (480).361-6269 F: (480).247-4993 ardebili@abceng.net MECHANICAL ENGINEER ATTN: FAISAL HALIS 15974 N.77TH ST. SUITE 100 SCOTTSDALE, AZ 85260 P: (480).397.0054 F: (480).277.8288 fhalis@fmgroup.net BUILDING DEPARTMENT: BUILDING AND PLANNING DEPT. 22112 EL PASO RANCHO SANTA MARGARITA, CA. 92688 P: (949) 635.1800 ACP ACT AL ALUM ARCH AVG. BLDG BLKG BR CMU CT CFM CL CLG CONC CONT CW DTL DF DIA DIM DN DR DS DWG EA ELEV EXIST or E. EXT. FDN FIN FD FL ACOUSTICAL CLG. PANEL ACOUSTICAL CLG. TILE ALUMINUM ALUMINUM ARCHITECTURAL AVERAGE BUILDING BLOCKING BRICK CONCRETE BLOCK CERAMIC TILE CUBIC FEET PER MINUTE CENTER LINE CEILING CONCRETE CONTINUOUS COLD WATER DETAIL DRINKING FOUNTAIN DIAMETER DIMENSION DOWN DOOR DOWNSPOUT DRAWING EACH ELEVATION EXISTING EXTERIOR FOUNDATION FINISH FLOOR DRAIN FLOOR FLASH. FLASHING FURNISHED BY OWNER FOIC INSTALLED BY CONTRACTOR FO FINISH OPENING FRP FIBERGLASS REINFORCED PANELS FRT FIRE RETARDANT TREATED GA GAUGE GALV GALVANIZED GL GLASS GWB GYPSUM WALLBOARD HDWE HARDWARE HM HOLLOW METAL HOR HORIZONTAL HT HEIGHT HW HOT WATER HWT HOT WATER TANK LAV LAVATORY LT LIGHT MAT'L MATERIAL MAX MAXIMUM MTL METAL MIN MINIMUM M.O. MASONRY OPENING MUL MULLION N/A NOT APPLICABLE NIC NOT IN THIS CONTRACT NO. NUMBER NOMINAL NOM NOT TO SCALE NTS ON CENTER O.C. OUTSIDE DIMENSION OD PAINT PT PLASTIC LAMINATE P.LAM PLUMBING DRAWINGS P1.0 PLUMBING SPECIFICATIONS AND CALCS P2.0 PLUMBING FLOOR PLAN P3.0 PLUMBING RISER DIAGRAM P4.0 PLUMBING DETAILS P5.0 PLUMBING SPECIFICATIONS ELECTRICAL DRAWINGS ABBREVIATIONS 680 SF / 200 LOAD FACTOR = 3.4 (4) SPECIFICATIONS TITLE 24 COMPLIANCE 1,099 SF / 30 LOAD FACTOR = 36.6 (37) OFFICE OR PUBLIC BUILDING (AREA ACCESSIBLE TO THE PUBLIC SP1.3 M0.2 LOAD FACTOR (SQ. FT.) CONFERENCE ROOMS, DINING ROOMS, DRINKING EXTABLISHMENTS, EXHIBIT ROOMS,GYMNASIUMS, LOUNGES, STAGES, AND SIMILAR USES, INCLUDING RESTAURANTS CLASSIFIED AS GROUP B OCCUPANCIES SPECIFICATIONS INSTALL NEW KITCHEN EQUIPMENT 3 250 FT PER 2013 CBC TABLE 1016.2 SP1.2 TENANT BUILD-OUT OF RESTAURANT 96" 2 SPECIFICATIONS TITLE 24 COMPLIANCE PROVIDED 14.6" SP1.1 M0.1 EXIT WIDTH ANALYSIS EXIT AREAS SPECIFICATIONS USING EXISTING MECHANICAL, ELECTRICAL, AND PLUMBING, ADDING REQUIRED SEE MPE DRAWINGS FRANCHISE/OWNER INFORMATION: JANE WABS 1742 TAYLOR LANE PLACENTIA, CA. 92870 P: 78 SP1.0 MECHANICAL DRAWINGS THE PROPOSED PROJECT INCLUDES: GENERAL NOTES 0 ACCESSIBILITY REQUIREMENTS / DETAILS DICKEY'S STORE # CA-1239 N/A date 2013 CALIFORNIA GREEN BUILDING STANDARDS CODE revision 2013 CALIFORNIA FIRE CODE PLYWOOD RISER, RADIUS REINFORCING BAR REFERENCE REVISION ROOM, ROOMS ROUGH OPENING STAIN AND VARNISH SOLID CORE SCHEDULE SECTION SHEET SPECIFICATIONS SQUARE FEET STEEL STORAGE STRUCTURAL SUSPENDED SHEET VINYL STAINLESS STEEL TELEPHONE MOUNTING BOARD TRENCH DRAIN TD THRESH THRESHOLD TYPICAL TYP UNFINISHED UNFIN URINAL UR VINYL COMPOSITION VCT TILE VERTICAL VERT VINYL SAFETY TILE VST WIDTH W WATER CLOSET WC WOOD WD WINDOW WDW WATERPROOF WP PLYWD R REBAR REF REV RM. RMS RO S&V SC SCHED SEC SHT SPECS SF ST STOR STRUCT SUSP SV SS TB E0.0 TITLE 24 COMPLIANCE E0.2 TITLE 24 COMPLIANCE E0.2 TITLE 24 COMPLIANCE E1.0 ELECTRICAL LIGHTING PLAN E2.0 ELECTRICAL POWER FLOOR PLAN E2.1 ELECTRICAL MECHANICAL POWER FLOOR PLAN E3.0 ELECTRICAL ONE-LINE DIAGRAM FM GROUP PROJECT NO. 16-047 2013 CALIFORNIA ENERGY CODE 30451 AVENIDA DE LAS FLORES SUITE "E" RANCHO SANTA MARGARITA, CA. 92688 COVER SHEET SUBMITTAL A0.0 0 2013 CALIFORNIA PLUMBING CODE 02.18.16 ARCHITECTURAL DRAWINGS 2013 CALIFORNIA MECHANICAL CODE no. BUILDING CODES THIS DRAWING AND ITS CONTENTS ARE THE COPYRIGHTED PROPERTY OF FM GROUP INC. USE THEREOF IS LIMITED TO THE SPECIFIC PROJECT AND SITE SET FORTH ABOVE, AND MAY NOT BE OTHERWISE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN PERMISSION OF FM GROUP INC, THE ARCHITECT. THIS DRAWING IS TO BE RETURNED UPON REQUEST SYMBOL LEGEND X/X.X INTERIOR/EXTERIOR ELEVATIONS X-X X/X.X X DEFERRED SUBMITTALS ALL DEFERRED SUBMITTALS SHALL BE SUBMITTED WITHIN 60 DAYS OF BUILDING PERMIT ISSUANCE. NO WORK IS TO BE PERFORMED ON ANY DEFERRED SUBMITTALS UNTIL THEY HAVE BEEN REVIEWED, APPROVED & ISSUED. TITLE SHEET FIRE ALARM / SPRINKLER SYSTEM DESIGN EXTERIOR SIGNS XXXXX XXX DEFERRED SUBMITTAL ITEMS SHALL BE DESIGNED BY AN CALIFORNIA REGISTRANT WITH LICENSE IN THAT DISCIPLINE. PLANS SHALL BE SUBMITTED TO THE CITY OF RANCHO SANTA MARGARITA BUILDING AND SAFETY DEPARTMENT FOR PERMITS BEFORE ANY FABRICATION OF THESE ITEMS OCCURS. VICINITY MAP N A0.0 15974 N. 77th STREET SUITE 100 SCOTTSDALE, AZ 85260 602.277.7877 02.18.16 date 4 EXISTING ACCESSIBLE PARKING SPACES WITH SIGNAGE TO REMAIN 5 PATH OF TRAVEL INDICATES! INDICATES: ACCESSIBLE PATH OF TRAVEL, SHALL BE MINIMUM 48" WIDE FROM ARRIVAL POINT TO MAIN ENTRANCE NOTE: ACCESSIBLE PATH OF TRAVEL; SHALL BE MINIMUM 48" WIDE FROM ARRIVAL POINT TO THE MAIN ENTRANCE TO BE A BARRIER FREE ACCESS ROUTE. WITHOUT ANY ABRUPT LEVEL CHANGES EXCEEDING 1/2" AT LEAST 48" IN WIDTH. CROSS SLOPE DOES NOT EXCEED 2% AND SLOPE IN THE DIRECTION OF TRAVEL IS LESS THAN 5% SURFACE IS STABLE, FIRM AND SLIP RESISTANT. FREE OF OVERHANGING OBSTRUCTIONS TO 80" MINIMUM, PROTRUDING OBJECTS GREATER THAN 4" PROJECTION FROM WALL & ABOVE 27" AND LESS THAN 80". Dickey's FM GROUP PROJECT NO. 16-047 EXISTING SIDEWALKS TO REMAIN. 30451 AVENIDA DE LAS FLORES SUITE "E" RANCHO SANTA MARGARITA, CA. 92688 3 DICKEY'S STORE # CA-1239 EXISTING LANDSCAPE AREAS SUBMITTAL 2 0 EXISTING STRIPED PARKING NOT TO BE CHANGED no. 1 revision SITE KEYNOTES EXISTING SITE NO NEW WORK FOR REFERECE ONLY 1 SITE PLAN SCALE: N.T.S. N THIS DRAWING AND ITS CONTENTS ARE THE COPYRIGHTED PROPERTY OF FM GROUP INC. USE THEREOF IS LIMITED TO THE SPECIFIC PROJECT AND SITE SET FORTH ABOVE, AND MAY NOT BE OTHERWISE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN PERMISSION OF FM GROUP INC, THE ARCHITECT. THIS DRAWING IS TO BE RETURNED UPON REQUEST SITE PLAN A0.1 KEYED NOTES 15974 N. 77th STREET SUITE 100 SCOTTSDALE, AZ 85260 602.277.7877 DEMOLITION GENERAL NOTES LEGEND RADON / MOISTURE BARRIER NOTE: THE CONTRACTOR SHALL VISIT THE SITE AND BE KNOWLEDGEABLE OF CONDITIONS THEREOF. HE SHALL INVESTIGATE, VERIFY AND BE RESPONSIBLE FOR ALL CONDITIONS OF THE PROJECT AND SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF ANY INCONSISTENCIES OR DISCREPANCIES WITH THE PLANS IN RELATION TO THE EXISTING FIELD CONDITIONS OR ANY CONDITIONS REQUIRING MODIFICATION BEFORE PROCEEDING WITH THE WORK. COMMENCEMENT OF WORK SHALL CONSTITUTE ACCEPTANCE OF EXISTING CONDITIONS. GC TO BRING SALES AREA TO A "SHELL" CONDITION" IN ORDER TO ACCEPT NEW FIXTURE LAYOUT AS PER NEW FIXTURE PLAN. CONTRACTOR TO COORDINATE & REVIEW ALL CONSTRUCTION DOCUMENTS & DETERMINE THE EXTENT OF DEMOLITION WORK & BECOME FAMILIAR WITH THEM THOROUGHLY BEFORE PERFORMING ANY DEMOLITION WORK. BY THE ACT OF SUBMITTING A BID, THE CONTRACTOR WILL BE DEEMED TO HAVE COMPLIED WITH THE FOREGOING TO HAVE ACCEPTED SUCH CONDITIONS AND TO HAVE MADE ALLOWANCES THEREFORE IN PREPARING HIS BID. 6. 7. EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, SALVAGED, OR DETERMINED BY OWNER TO REMAIN THE OWNER'S PROPERTY, DEMOLISHED MATERIALS SHALL BECOME THE CONTRACTOR'S PROPERTY AND SHALL BE REMOVED FROM THE SITE. PROMPTLY DISPOSE OF DEMOLISHED MATERIALS. DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ON SITE. TRANSPORT DEMOLISHED MATERIALS OFF OWNER'S PROPERTY AND LEGALLY DISPOSE OF THEM TO ENSURE MINIMAL INTERFERENCE WITH ROADS, STREETS, WALKS, AND OTHER ADJACENT OCCUPIED AND USED FACILITIES. REMOVE & TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT SPILLAGE ON ADJACENT SURFACES AND AREAS. 8. STORAGE OR SALE OF REMOVED ITEMS OR MATERIALS ON-SITE WILL NOT BE PERMITTED. 9. EXECUTE THE WORK IN A CAREFUL AND ORDERLY MANNER. COORDINATE ALL WORK WITH THE LANDLORD/PROPERTY MANAGER TO VERIFY USE OF THE STORAGE ROOM, POWER, TEMPORARY STORAGE, SITE ACCESS, HOURS OF WORK ETC.. TYP 10. SUBMIT WRITTEN REQUEST IN ADVANCE OF CUTTING OR ALTERING ELEMENTS WHICH AFFECT: a. STRUCTURAL INTEGRITY OF ELEMENT b. INTEGRITY OF WEATHER EXPOSED OR MOISTURE RESISTANT ELEMENTS. 11. PROVIDE TEMPORARY BRACING AND SHORING WITH CONNECTIONS OF SUFFICIENT STRENGTH TO BEAR IMPOSED LOADS, AND TO PROTECT ALL PERSONS AND PROPERTY, AND TO ENSURE PROPER ALIGNMENT. COMPLY WITH ALL STATE, O.S.H.A. AND LOCAL CODES. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR PROVIDING ADEQUATE BRACING OF WALLS DURING DEMOLITION AND ERECTION TO PREVENT DAMAGE DUE TO HIGH WINDS OR OTHER LATERAL LOADS AND CONSTRUCTION IMPACTS. CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR DAMAGE DUE TO HIS FAILURE TO TAKE SUCH PRECAUTIONS. 12. SURVEY THE CONDITION OF THE BUILDING TO DETERMINE WHETHER REMOVING ANY ELEMENT MIGHT RESULT IN STRUCTURAL DEFICIENCY OR UNPLANNED COLLAPSE OF ANY PORTION OF THE STRUCTURE OR ADJACENT STRUCTURES DURING DEMOLITION. 13. REMOVE & REINSTALL ITEMS INDICATED; CLEAN, SERVICE, AND OTHERWISE PREPARE THEM FOR REUSE; STORE AND PROTECT AGAINST DAMAGE. REINSTALL ITEMS IN LOCATIONS INDICATED. 14. THE CONTRACTOR SHALL PROTECT ALL UNALTERED PORTIONS OF THE EXISTING CONDITIONS, AS NECESSARY. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGE TO EXISTING WORK AND WORK BY OTHERS. 15. MAINTAIN EXISTING UTILITIES WHERE APPLICABLE TO REMAIN IN SERVICE AND PROTECT THEM AGAINST DAMAGE DURING SELECTIVE DEMOLITION OPERATIONS. VERIFY THAT SERVICE IS NOT DISCONNECTED IN OTHER TENANT SPACES DURING DEMOLITION. 16. PROVIDE TEMPORARY WEATHER PROTECTION, DURING INTERVAL BETWEEN DEMOLITION AND REMOVAL OF EXISTING CONSTRUCTION, ON EXTERIOR SURFACES AND NEW CONSTRUCTION TO ENSURE THAT NO WATER DAMAGE OCCURS TO STRUCTURE, EXTERIOR, OR INTERIOR AREAS. G.C. TO PLACE WALK-OFF MATS AT EXITS TO CONTROL THE TRACKING OF DUST, DIRT AND DEBRIS INTO LANDLORD'S COMMON AREAS. 17. PROTECT WALLS, ROOF, SIDEWALKS, AND OTHER EXISTING FINISH WORK THAT ARE TO REMAIN AND ARE EXPOSED DURING SELECTIVE DEMOLITION OPERATIONS. 18. GENERAL CONTRACTOR TO REVIEW CONDITION OF CONCRETE SLABS (INTERIOR & EXTERIOR) TO BE RE-USED WITH OWNER'S CONSTRUCTION MANAGER AFTER DEMOLITION OF EXISTING WALLS, FLOORS, & CEILINGS IS COMPLETE. GENERAL CONTRACTOR TO REVIEW PATCH LOCATIONS & COLOR FOR: TRENCHING LOCATIONS FOR NEW PLUMBING; NON-COMPLIANT CODE CONDITIONS; AND SIGNIFICANT COSMETIC DEFECTS WITH OWNER'S CONSTRUCTION MANAGER. FM GROUP PROJECT NO. 16-047 COMPLY WITH GOVERNING EPA NOTIFICATION REGULATIONS BEFORE STARTING DEMOLITION. COMPLY WITH HAULING AND DISPOSAL REGULATIONS OF AUTHORITIES HAVING JURISDICTION. REMOVE AND LEGALLY DISPOSE OF ITEMS EXCEPT THOSE INDICATED TO BE REINSTALLED, SALVAGED, OR TO REMAIN THE OWNER'S PROPERTY. 30451 AVENIDA DE LAS FLORES SUITE "E" RANCHO SANTA MARGARITA, CA. 92688 6. . DICKEY'S STORE # CA-1239 FIELD VERIFY ALL DIMENSIONS AND BRING ANY DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT. DO NOT SCALE DRAWINGS. ALL DIMENSIONS LOCATING WALLS ARE TAKEN FROM OUTSIDE FACE OF EXISTING PARTITIONS OR SURFACE OF MASONRY UNLESS OTHERWISE INDICATED. AFTER PLUMBING ROUGH-INS ARE COMPLETE G.C. TO POUR CONCRETE SLAB TO MATCH THICKNESS OF EXISTING.ON GRADE W/#3 REINFORCING (NOT TO BE LESS THAN EXIST.) @ 18" O.C. EA. WAY ON 6" COMPACTED GRANULAR AGGREGATE SUB BASE MATERIAL. SEE DETAIL 2/A1.0 02.18.16 5. CONCRETE NOTE: SUBMITTAL PLANS SHOW GENERAL DEMOLITION WORK TO BE PERFORMED AND DOES NOT RELIEVE THE CONTRACTOR FROM OTHER DEMOLITION WORK REQUIRED TO PRODUCE THE BUILDING MODIFICATIONS SHOWN ON THE REMAINING CONTRACT DOCUMENTS, INCLUDING THE PLUMBING, MECHANICAL & ELECTRICAL DRAWINGS. WORK INCLUDES REMOVAL AND LEGAL DISPOSAL OF ALL EXISTING CONSTRUCTION ITEMS THAT ARE NOT UTILIZED IN THE FINISHED PROJECT. REMOVE ALL ITEMS SPECIFICALLY INDICATED IN THE DRAWINGS AND ITEMS WHICH ARE NECESSARY TO BE REMOVED IN ORDER TO FACILITATE THE FINISHED PROJECT. 7. EXISTING INTERIOR PARTITION TO REMAIN 0 4. 4. 5. EXISTING INTERIOR PARTITION TO BE REMOVED G.C. TO INSTALL RADON BARRIER MEMBRANE AT ALL NEW CONCRETE LOCATIONS. MIN. OF 0.3mm THICKNESS. BARRIER TO BE INSTALLED PER MANUFACTURE INSTRUCTIONS AND PROVIDE RADON AIR-TIGHTNESS AND MOISTURE SEAL. date 3. 3. SURVEY THE CONDITION OF THE BUILDING TO DETERMINE WHETHER REMOVING ANY ELEMENT MIGHT RESULT IN A STRUCTURAL DEFICIENCY OR UNPLANNED COLLAPSE OF ANY PORTION OF THE STRUCTURE OR ADJACENT STRUCTURES DURING DEMOLITION AND NOTIFY ARCHITECT BEFORE PROCEEDING. PERFORM SURVEYS AS THE WORK PROGRESSES TO DETECT HAZARDS RESULTING FROM DEMOLITION ACTIVITIES. EXISTING DEMISING WALL TO REMAIN revision 2. 2. EXISTING STOREFRONT, WINDOWS, AND DOORS TO REMAIN, G.C. TO VERIFY PROPER WORKING CONDITION OF DOORS AND DOOR HARDWARE. G.C. TO INSPECT ALL GLASS AND REPLACE ANY BROKEN OR CRACKED PANES. LOCATION OF EXISTING ONE HOUR DEMISING WALL SEE A6.0 FOR WALL TYPE AND DETAILS. EXISTING EXTERIOR WALLS. REMOVE ANY UN-NEEDED FINISHES ON INTERIOR SIDE AND PREPARE FOR NEW WALL FINISH-SEE FINISH SCHEDULE AND WALL TYPES EXISTING EXTERIOR LIGHTING TO REMAIN LOCATION OF NEW ENTRY DOOR INSTALLED IN STOREFRONT. REMOVE EXISTING WINDOW AND REPLACE WITH LIKE DOOR AND ADJACENT SIDE WINDOW. REMOVE ALL FLOORING TO EXISTING CONCRETE. G.C. TO INSPECT AND REPAIR ANY IMPERFECTIONS. EXISTING CONCRETE FLOOR TO REMAIN. SAWCUT FOR ADDITIONAL TRENCHING FOR UNDERGROUND UTILITIES. NEW CONCRETE POURED AFTER ALL NEW CONNECTIONS ARE COMPLETE AND INSPECTED. MOISTURE/RADON BARRIER INSTALLED AS REQUIRED. SEE RADON/MOISTURE NOT THIS SHEET. no. 1. 1. TYP 19. ANY EXISTING FINISHED SURFACES TO REMAIN THAT ARE AFFECTED BY SELECTIVE DEMOLITION SHALL BE PATCHED TO MATCH EXISTING ADJACENT SURFACES UNLESS CONCEALED BY NEW CONSTRUCTION 20. WHERE NEW WORK ADJOINS EXISTING WORK, THE CONTRACTOR SHALL DO ALL NECESSARY CUTTING, PATCHING AND FITTING. JUNCTURES OF NEW AND EXISTING OR OTHER WORK SHALL BE REPAIRED AND PATCHED TO MATCH ADJACENT EXISTING SURFACES. EXISTING WALLS REQUIRING MODIFICATION OF ANY KIND SHALL BE REFINISHED TO THE NEAREST OUTSIDE OR INSIDE CORNER. 21. DISCONNECT AND REMOVE AND/OR CAP ALL EXISTING UTILITIES (ELECTRIC, GAS, WATER, SANITARY & STORM) WHERE SCHEDULED NOT TO BE REUSED, IN ACCORDANCE WITH CITY AND GOVERNING CODE AND UTILITY COMPANY REQUIREMENTS. 22. PROVIDE TEMPORARY LIGHTING/POWER AS REQUIRED, DURING AND AFTER DEMOLITION FOR ALL AREAS WITHIN LIMITS OF THIS CONTRACT. SUCH SERVICE SHALL BE TAKEN FROM EXISTING PANEL BOARDS, AND EXISTING EQUIPMENT MAY BE UTILIZED WHERE FEASIBLE. 23. ALL EXISTING CONDUIT AND WIRE INTERFERING WITH THE NEW WORK SHALL BE REROUTED CONCEALED IN THE NEW CONSTRUCTION, UNLESS NOTED OTHERWISE. 24. ALL UNUSED CONDUIT AND WIRE REMOVED SHALL BE REMOVED COMPLETELY BACK TO SOURCE, AND BRANCH OVER-CURRENT PROTECTIVE DEVICES PROPERLY LABELED "SPARE". 25. UPON COMPLETION OF THE NEW INSTALLATION WORK, DISCONNECT, REMOVE, AND PROPERLY DISPOSE OF ALL TEMPORARY LIGHTING, POWER, AND WIRING. 26. PROVIDE PHOTOGRAPHS OR VIDEOTAPE, SUFFICIENTLY DETAILED, OF EXISTING CONDITIONS OF ADJOINING CONSTRUCTION AND SITE IMPROVEMENTS THAT MIGHT BE MISCONSTRUED AS DAMAGE CAUSED BY DEMOLITION OPERATIONS. 27. CLEAN ALL HORIZONTAL SURFACES OF ACCUMULATED DUST AND DEBRIS. SWEEP THE BUILDING BROOM CLEAN ON COMPLETION OF DEMOLITION OPERATION. 28. SHOULD THE CONTRACTOR ENCOUNTER SUSPICIOUS MATERIAL OR BECOME AWARE OF THE PRESENCE OFASBESTOS CONTAINING MATERIALS, THEN THE CONTRACTOR SHALL IMMEDIATELY NOTIFY OWNER OF SUCH CONDITIONS. THE CONTRACTOR SHALL NOT PROCEED WITH WORK IN THESE AREAS UNTIL OWNER HAS RETAINED A QUALIFIED SPECIALIST CONTRACTOR TO VALIDATE, ABATE, ENCAPSULATE OR OTHERWISE ADDRESS THE ASBESTOS-CONTAINING MATERIALS AND WARRANT TO THE CONTRACTOR THAT THE WORK CAN PROCEED IN FULL COMPLIANCE WITH APPLICABLE LAWS AND REGULATIONS. THIS DRAWING AND ITS CONTENTS ARE THE COPYRIGHTED PROPERTY OF FM GROUP INC. USE THEREOF IS LIMITED TO THE SPECIFIC PROJECT AND SITE SET FORTH ABOVE, AND MAY NOT BE OTHERWISE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN PERMISSION OF FM GROUP INC, THE ARCHITECT. THIS DRAWING IS TO BE RETURNED UPON REQUEST 29. MODIFY EXISTING FIRE SPRINKLER AS REQUIRED BY NEW CONSTRUCTION AND DESIGN BY TENANT G.C. SPRINKLER DESIGN TO BE DESIGN BUILD UNDER SEPARATE PERMIT. SPRINKLER CONTRACTOR TO PROVIDE DRAWINGS TO LOCAL JURISDICTION AS REQUIRED FOR SPRINKLER PERMIT. G.C. TO COORDINATE WITH LANDLORD APPROVED SPRINKLER CONTRACTOR IN REGARDS TO DESIGN, PERMITTING AND INSTALLATION. ALL SPRINKLER MODIFICATION/INSTALL WORK WILL BE UNDER A SEPARATE PERMIT SUBMITTAL. 30. G.C. TO COORDINATE FIRE ALARM SYSTEM MODIFICATION WITH LANDLORD PREFERRED FIRE ALARM CONTRACTOR PER NEW FLOOR PLAN. ALL FIRE ALARM MODIFICATION/INSTALL WORK TO BE UNDER SEPARATE PERMIT. 31. G.C. SHALL COORDINATE WORK WITH MALL MANAGER TO INSURE MINIMAL DISRUPTION TO MALL OPERATIONS AND ADJACENT TENANTS. 32. G.C. TO REUSE ANY EXISTING IMPROVEMENTS, EQUIPMENT AND UTILITY SYSTEMS, PROVIDED THEY ACKNOWLEDGE RESPONSIBILITY FOR THE REPAIR, REPLACEMENT OR UPGRADE OF SUCH IF DETERMINED TO BE NON COMPLAINT WITH LATEST CODE, NOT DESIGNED OR APPLICABLE FOR PROPOSED APPLICATION, DAMAGED OR NON OPERATIONAL. 33. DURING DEMO FIRE SPRINKLER SYSTEM MUST BE BLANKED OFF PRIOR TO COMMENCING DEMOLITION EXISTING FLOOR PLAN & MINOR DEMO TYP EXISTING/DEMO FLOOR PLAN 1 SCALE: N TYP 34. HAUL DEBRIS AWAY DAILY, DEBRIS MUST NOT BE STORED IN THE SPACE A1.0 4. 5. 6. 7. 8. 9. 10. 11. 12. 1 A1.1 DIMENSIONED FLOOR PLAN N 13. 1/4" = 1'-0" 14. 15. 16. 17. SUBMITTAL 02.18.16 15974 N. 77th STREET SUITE 100 SCOTTSDALE, AZ 85260 602.277.7877 3. FM GROUP PROJECT NO. 16-047 30451 AVENIDA DE LAS FLORES SUITE "E" RANCHO SANTA MARGARITA, CA. 92688 2. ALL DIMENSIONS OF NEW WALLS ARE FROM FACE OF STUD, UNLESS OTHERWISE NOTED. ALL GYPSUM BOARD USED SHALL BE 5/8" TYPE 'X' FIRE TAPED. DEMISING PARTITIONS SHALL BE OF FIRECODE "X" SHEETROCK, TAPED AND SEALED TO DECK ABOVE. ALL PLYWOOD, PLYWOOD BACKING, PARTICLE BOARD, WOOD BLOCKING, AND FRAMING USED SHALL BE FIRE RETARDANT & STAMPED NON-COMBUSTIBLE. PLACE AND FINISH ALL NEW MATERIALS SO AS TO PROVIDE A SMOOTH & INTEGRAL TRANSITION TO EXISTING FINISHES & MATERIALS. PROVIDE ADDITIONAL FRAMING/BRACING FOR ALL WALL MOUNTED EQUIPMENT. CHECK CUTSHEETS OF ALL EQUIPMENT PRIOR TO INSTALLATION. GENERAL CONTRACTOR TO PROVIDE REQUIRED FIRE EXTINGUISHER(S) PER CODE. FIRE SPRINKLERS: ADDITIONS & MODIFICATIONS AS REQUIRED BY CODE AND NFPA PAMPHLET #13. SPRINKLER HEADS CENTERED WITHIN CEILING BOARD. SPRINKLER HEADS AT GYPSUM BOARD CEILINGS MUST BE FULLY RECESSED AND COVERED WITH METAL PLATES FINISHED TO MATCH ADJACENT SURFACE. CENTER SPRINKLER HEADS IN CEILING-WHERE APPLICABLE. ANY MODIFICATIONS TO BE DONE BY LANDLORD'S SPECIFIED SPRINKLER CONTRACTOR. ALL COSTS FOR SPRINKLER RE-LOCATION TO CONFORM WITH FIT OUT DESIGN ARE PROVIDED BY TENANT. - WHEN APPLICABLE. SEE MECHANICAL AND ELECTRICAL SHEETS FOR ALL FIXTURE SPECIFICATIONS, WIRING, AND POWER REQUIREMENTS. - VERIFY WITH EQ SHEETS. NEWLY INSTALLED OR RELOCATED DOORS MUST HAVE LEVER TYPE HARDWARE OR OTHER SHAPE WHICH WILL PERMIT OPERATION BY WRIST OR ARM PRESSURE AND WHICH DOES NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING TO OPERATE, PER WAC 51.20.3103 (A) AND (C). ALL DOORS TO PROVIDE 32" MIN. CLEAR OPENING WHEN OPENED TO 90 DEGREE POSITION. FLOORS IN FOOD PREPARATION AREA, DISH WASHING AREA, SERVICE AREA, JANITORIAL AREA, STORAGE AREA, AND ANY AREA WHERE FOR EQUIPMENT IS PLACED SHALL BE SMOOTH, EASILY CLEANABLE, WASHABLE, DURABLE, AND OF COMMERCIAL GRADE MATERIAL AND SHALL HAVE A MINIMUM 3/8" RADIUS INTEGRAL COVE BASE EXTENDING AT LEAST 4" UP THE WALL. GROUT SPACING FOR TILE SHALL NOT EXCEED 1/4" AND SHALL BE SEALED. GC TO CONTACT FM GROUP FOR ADDITIONAL INFORMATION PRIOR TO BIDING CABINETS. CONTRACTOR SHOULD SUBMIT SHOP DRAWINGS FOR APPROVAL. TENANT'S GC TO COMPLETE SITE VISIT AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS - GC TO REVIEW TENANT'S LEASE DURING BID PROCESS TO DETERMINE RESPONSIBILITIES. FLOOR SINKS SHALL BE INSTALLED FLUSH WITH THE FLOOR SURFACE AND BE LOCATED SO AS TO BE READILY ACCESSIBLE FOR CLEANING AND REPAIR. SUPPORT WIRING FOR LAY-IN CEILING SHALL NOT BE ATTACHED TO ANY OF THE LANDLORD'S MECH, ELEC, PLUMB, OR FIRE PROTECTION PIPING OR EQUIPMENT. ALL EXITS SHALL BE OPERABLE FROM INTERIOR OF BUILDING WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. ALL EXTERIOR WALLS AND RESTROOM WALLS TO BE INSULATED. DICKEY'S STORE # CA-1239 1. 0 date revision no. GENERAL NOTES THIS DRAWING AND ITS CONTENTS ARE THE COPYRIGHTED PROPERTY OF FM GROUP INC. USE THEREOF IS LIMITED TO THE SPECIFIC PROJECT AND SITE SET FORTH ABOVE, AND MAY NOT BE OTHERWISE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN PERMISSION OF FM GROUP INC, THE ARCHITECT. THIS DRAWING IS TO BE RETURNED UPON REQUEST RE: WALL TYPES 6/A6.0 NEW WALLS/ WALL INFILL NEW PARTIAL HEIGHT WALLS DIMENSION PLAN NEW DEMISING WALLS TO REMAIN EXISTING WALLS TO REMAIN NEW COOLER/FREEZER WALLS A1.1 4 CORNER GUARDS; RE: 4/A5.0 SEE KITCHEN ELEVATIONS 5 HANDICAP ACCESSIBLE SIGN; RE: LS1.0 6 FIRE EXTINGUISHER (K-TYPE WITHIN 30 FEET OF HOOD SYSTEM WHERE APPLICABLE) 7 EXHAUST HOOD; RE: MECHANICAL 8 TACTILE 'EXIT ROUTE' SIGN, VERIFY FINAL LOCATION AND WORDING WITH FIRE MARSHAL PRIOR TO INSTALLATION 9 OCCUPANCY LOAD SIGN, VERIFY LOCATION WITH FIRE MARSHALL PRIOR TO INSTALLATION 10 NEW WASTE RECEPTACLE; 11 NEW MILLWORK; RE: 3/A5.0 12 NEW BEVERAGE BAR; RE 13 STEEL REINFORCING POST; RE: 1/A6.0 14 G.C. TO VERIFY THE COOLER DIMENSIONS TO ENSURE PROPER INSTALLATION OF THE COOLER 15 NEW BEVERAGE DISPENSER 16 LOCATION OF CO2 TANKS 17 EXISTING REAR ENTRY DOOR. SEE DOOR SCHEDULE FOR HARDWARE 18 LOCATION OF NEW WATER HEATER 19 NEW BEVERAGE COOLER 20 LOW WALL 21 NEW STOREFRONT DOOR AND SIDE WINDOW SEE DOOR SCHEDULE 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 2 A1.2 FLOOR PLAN 1/4" = 1'-0" 15. N 16. 17. ALL DIMENSIONS OF NEW WALLS ARE FROM FACE OF STUD, UNLESS OTHERWISE NOTED. ALL GYPSUM BOARD USED SHALL BE 5/8" TYPE 'X' FIRE TAPED. DEMISING PARTITIONS SHALL BE OF FIRECODE "X" SHEETROCK, TAPED AND SEALED TO DECK ABOVE. ALL PLYWOOD, PLYWOOD BACKING, PARTICLE BOARD, WOOD BLOCKING, AND FRAMING USED SHALL BE FIRE RETARDANT & STAMPED NON-COMBUSTIBLE. PLACE AND FINISH ALL NEW MATERIALS SO AS TO PROVIDE A SMOOTH & INTEGRAL TRANSITION TO EXISTING FINISHES & MATERIALS. PROVIDE ADDITIONAL FRAMING/BRACING FOR ALL WALL MOUNTED EQUIPMENT. CHECK CUTSHEETS OF ALL EQUIPMENT PRIOR TO INSTALLATION. GENERAL CONTRACTOR TO PROVIDE REQUIRED FIRE EXTINGUISHER(S) PER CODE. FIRE SPRINKLERS: ADDITIONS & MODIFICATIONS AS REQUIRED BY CODE AND NFPA PAMPHLET #13. SPRINKLER HEADS CENTERED WITHIN CEILING BOARD. SPRINKLER HEADS AT GYPSUM BOARD CEILINGS MUST BE FULLY RECESSED AND COVERED WITH METAL PLATES FINISHED TO MATCH ADJACENT SURFACE. CENTER SPRINKLER HEADS IN CEILING-WHERE APPLICABLE. ANY MODIFICATIONS TO BE DONE BY LANDLORD'S SPECIFIED SPRINKLER CONTRACTOR. ALL COSTS FOR SPRINKLER RE-LOCATION TO CONFORM WITH FIT OUT DESIGN ARE PROVIDED BY TENANT. - WHEN APPLICABLE. SEE MECHANICAL AND ELECTRICAL SHEETS FOR ALL FIXTURE SPECIFICATIONS, WIRING, AND POWER REQUIREMENTS. - VERIFY WITH EQ SHEETS. NEWLY INSTALLED OR RELOCATED DOORS MUST HAVE LEVER TYPE HARDWARE OR OTHER SHAPE WHICH WILL PERMIT OPERATION BY WRIST OR ARM PRESSURE AND WHICH DOES NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING TO OPERATE, PER WAC 51.20.3103 (A) AND (C). ALL DOORS TO PROVIDE 32" MIN. CLEAR OPENING WHEN OPENED TO 90 DEGREE POSITION. FLOORS IN FOOD PREPARATION AREA, DISH WASHING AREA, SERVICE AREA, JANITORIAL AREA, STORAGE AREA, AND ANY AREA WHERE FOR EQUIPMENT IS PLACED SHALL BE SMOOTH, EASILY CLEANABLE, WASHABLE, DURABLE, AND OF COMMERCIAL GRADE MATERIAL AND SHALL HAVE A MINIMUM 3/8" RADIUS INTEGRAL COVE BASE EXTENDING AT LEAST 4" UP THE WALL. GROUT SPACING FOR TILE SHALL NOT EXCEED 1/4" AND SHALL BE SEALED. GC TO CONTACT FM GROUP FOR ADDITIONAL INFORMATION PRIOR TO BIDING CABINETS. CONTRACTOR SHOULD SUBMIT SHOP DRAWINGS FOR APPROVAL. TENANT'S GC TO COMPLETE SITE VISIT AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS - GC TO REVIEW TENANT'S LEASE DURING BID PROCESS TO DETERMINE RESPONSIBILITIES. FLOOR SINKS SHALL BE INSTALLED FLUSH WITH THE FLOOR SURFACE AND BE LOCATED SO AS TO BE READILY ACCESSIBLE FOR CLEANING AND REPAIR. SUPPORT WIRING FOR LAY-IN CEILING SHALL NOT BE ATTACHED TO ANY OF THE LANDLORD'S MECH, ELEC, PLUMB, OR FIRE PROTECTION PIPING OR EQUIPMENT. ALL EXITS SHALL BE OPERABLE FROM INTERIOR OF BUILDING WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. ALL EXTERIOR WALLS AND RESTROOM WALLS TO BE INSULATED. DICKEY'S STORE # CA-1239 no. GENERAL NOTES 1. 15974 N. 77th STREET SUITE 100 SCOTTSDALE, AZ 85260 602.277.7877 LOCATION OF ELECTRICAL PANELS FM GROUP PROJECT NO. 16-047 3 30451 AVENIDA DE LAS FLORES SUITE "E" RANCHO SANTA MARGARITA, CA. 92688 NEW FIRE LOG AND MERCHANDISE ACCENT. GC TO COORDINATE LOCATION SUBMITTAL 2 0 EXISTING STOREFRONT, WINDOWS, AND DOORS TO REMAIN date 1 02.18.16 NOTE: NOT ALL KEYNOTES MAY BE USED revision KEYED NOTES THIS DRAWING AND ITS CONTENTS ARE THE COPYRIGHTED PROPERTY OF FM GROUP INC. USE THEREOF IS LIMITED TO THE SPECIFIC PROJECT AND SITE SET FORTH ABOVE, AND MAY NOT BE OTHERWISE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN PERMISSION OF FM GROUP INC, THE ARCHITECT. THIS DRAWING IS TO BE RETURNED UPON REQUEST RE: WALL TYPES 6/A6.0 NEW WALLS/ WALL INFILL FLOOR PLAN NEW PARTIAL HEIGHT WALLS NEW DEMISING WALLS TO REMAIN EXISTING WALLS TO REMAIN NEW COOLER/FREEZER WALLS A1.2 15974 N. 77th STREET SUITE 100 SCOTTSDALE, AZ 85260 602.277.7877 NOTE: DOOR HARDWARE AT ALL EGRESS DOORS TO BE READILY OPENED FROM THE EGRESS SIDE, WITHOUT THE USE OF KEY, SPECIAL KNOWLEDGE, OR EFFORT. CBC 2013,1008.1.9 SEE "PANIC HARDWARE" DOOR SCHEDULE C XXX BUILDING AND FACILITY ENTRANCES THAT ARE ACCESSIBLE TO AND USABLE BY PERSONS WITH DISABILITIES SHALL BE IDENTIFIED WITH A MINIMUM OF ONE INTERNATIONAL SYMBOL OF ACCESSIBILITY AND WITH ADDITIONAL DIRECTIONAL SIGNS, UTILIZING THE SYMBOL, AT JUNCTIONS WHERE THE ACCESSIBLE ROUTE OF TRAVEL DIVERGES FROM THE REGULAR PATH, TO BE VISIBLE TO PERSONS ALONG APPROACHING CIRCULATION PATHS. REAR ENTRY (NEW) 3'-0" 7'-0" 1-3/4" A ALUM/GLASS ALUM. YES SIGN POSTED (DOORS TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED) . TEMPERED GLASS, NOTE #4, #5, #6, #7 102 SIDE ENTRY (EXISTING) 3'-0" 7'-0" 1-3/4" A ALUM/GLASS ALUM. YES 103 FRONT ENTRY (EXISTING) 3'-0" 7'-0" 1-3/4" A ALUM/GLASS ALUM. YES SIGN POSTED (DOORS TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED) . TEMPERED GLASS, NOTE #4, #5, #6, #7 SIGN POSTED (DOORS TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED) . TEMPERED GLASS, NOTE #4, #5, #6, #7 105 UNISEX RESTROOM 3'-0" 7'-0" 1-3/4" D WD. GLASS H.M. YES NOTES 1,2,3,6,7 (GLASS TO BE FROSTED) 106 UNISEX RESTROOM 3'-0" 7'-0" 1-3/4" D WD. GLASS H.M. YES NOTES 1,2,3,6,7 (GLASS TO BE FROSTED) NOTE:1 NOTE:2 NOTE:3 NOTE:4 NOTE:5 NOTE:6 NOTE 7 ALL INTERIOR DOORS WHITE RIFT OAK WITH CLEAR FINISH. ALL H.M. FRAMES TO BE TIMELY ALL LOCKSETS TO BE SCHLAGE CYLINDRICAL LOCKSETS - SPARTA SATIN CHROME FINISH. EXISTING DOORS TO BE INSPECTED BY G.C TO ENSURE PROPER WORKING AND LOCKING ORDER. ACCESSIBILITY AND EXIT SIGNAGE POSTED AT ENTRY DOOR THE BOTTOM 10" OF ALL DOORS SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE. PROVIDE STAINLESS STEEL KICKPLATE. AUTOMATIC DOOR CLOSURE INSTALLED, CLOSURE TO PROVIDE 3 SECONDS FOR DOOR TO CLOSE NOTE: DOOR HARDWARE AT ALL EGRESS DOORS TO BE READILY OPENED FROM THE EGRESS SIDE, WITHOUT THE USE OF KEY, SPECIAL KNOWLEDGE, OR EFFORT. CBC 1008.1.9 SEE PANIC HARDWARE INSTALLATION NOTE BELOW DOOR. 02.18.16 CONTRACTOR TO VERIFY EXISTING CONDITION MEET OR EXCEED CURRENT CBC 2013 CODES ) ALL 101 date EXIT DOORS MUST BE ABLE TO OPEN FROM THE INSIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR EFFORT. SEE EXCEPTION FOR ALLOWING KEY-LOCKING HARDWARE ON THE MAIN EXIT OF GROUP B, F, M AND S OCCUPANCIES. SURFACE-MOUNTED FLUSH OR SURFACE BOLTS ARE PROHIBITED. AUTOMATIC FLUSH BOLTS ARE ALLOWED ON PAIRS OF DOORS, PROVIDED THE DOOR WITH THE FLUSH BOLT HAS NO KNOBS OR SURFACE-MOUNTED HARDWARE AND THE UNLATCHING OF ANY LEAF REQUIRES ONLY A SINGLE OPERATION. (CBC 1003.3.1.8) SUBMITTAL FM GROUP PROJECT NO. 16-047 30451 AVENIDA DE LAS FLORES SUITE "E" RANCHO SANTA MARGARITA, CA. 92688 DICKEY'S STORE # CA-1239 0 no. 1. DOORS AND FRAMES TO BE FINISHED PER SCHEDULE, U.N.0. 2. DOOR CLOSERS ARE TO BE ADJUSTED TO COMPLY WITH THE FOLLOWING REQUIREMENTS: A. MAXIMUM EFFORT TO OPERATE DOORS (PUSH AND PULL) SHALL NOT EXCEED 5 POUNDS. B. SWEEP PERIOD OF THE CLOSER MUST BE ADJUSTED AND MAINTAINED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 INCHES FROM THE LATCH, MEASURED TO THE LANDING EDGE OF THE DOOR. 3. HAND ACTIVATED DOOR OPENING HARDWARE, DOOR HANDLES, LOCKS, AND OTHER OPERATING DEVICES SHALL BE INSTALLED AT A MIN. 34" AND A MAX. OF 44" A.F.F., AND BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE OR EQUIVALENT HARDWARE. 4. EVERY REQUIRED EXIT DOORWAY, WHICH IS LOCATED WITHIN AN ACCESSIBLE PATH OF TRAVEL, SHALL BE OF A SIZE AS TO PERMIT THE INSTALLATION OF A DOOR NOT LESS THAN 3' IN WIDTH AND NOT LESS THAN 6'-8" IN HEIGHT. (TO COMPLY WITH 2013 CBC) 5. REQUIRED EXIT DOORWAYS SHALL HAVE A MINIMUM 32" CLEAR OPENING WIDTH, WITH THE DOOR AT 90 DEG. TO THE CLOSED POSITION. PROVIDE PANIC HARDWARE. PROVIDE SIGN ABOVE DOOR FRAME. "THIS DOOR MUST REMAIN UNLOCKED WHEN THE BUILDING IS OCCUPIED." SEE 'DOOR SCHEDULE NOTES' #2, #3 6. LOCKS AND LATCHES SHALL RELEASE WITH ONE OPERATION FROM EGRESS SIDE. EXTERIOR DOORS SHALL OPEN OUTWARD AND BE SELF CLOSING AND TIGHT FITTING. REPLACE WEATHER STRIPPING AND THRESHOLDS AS REQUIRED.Z 7. VERIFY KEYING REQUIREMENTS WITH OWNER. 8. AT MAIN FLOOR EXIT/ENTRY DOORS PROVIDE SIGN ABOVE DOOR FRAME. "THIS DOOR MUST REMAIN UNLOCKED WHEN THE BUILDING IS OCCUPIED." SEE 'DOOR SCHEDULE NOTES' #2, #3 & #4. 9. ALL EXIT DOORS FROM AN ASSEMBLY (A) OCCUPANCY SHALL NOT BE PROVIDED WITH A LATCH OR LOCK, UNLESS IT IS PANIC HARDWARE. IBC 1008.1.10. THIS CORRECTION APPLIES TO TENANT IMPROVEMENT DOORS, AND THE COMMON EXIT RATED CORRIDOR EXIST DOOR. 10. GC TO COORDINATE W/LANDLORD TO MATCH EXISTING FINISHES 11. VERIFY CONDITION OF EXISTING HARDWARE AND THRESHOLDS. REPLACE AS REQUIRED FOR CODE COMPLIANCE. 12. GC TO VERIFY THAT EXISTING GLAZING IS CODE COMPLIANT. 13. NEW OR EXISTING DOOR FACES AND FRAMES THAT FACE ON THE PUBLIC AREA TO BE PAINTED P-1. NEW OR EXISTING DOOR FACES AND FRAMES THAT FACE ON BACK OF HOUSE AREAS TO BE PAINTED P-2. RE: SHEET A2.0 FINISH SCHEDULE FOR PAINT COLOR DETAILS. 14.. GC TO VERIFY THAT CODE COMPLIANT PANIC BARS ARE IN PLACE AND FULLY OPERATIONAL ON EXTERIOR EGRESS DOORS. revision DOOR SCHEDULE GENERAL NOTES: THIS DRAWING AND ITS CONTENTS ARE THE COPYRIGHTED PROPERTY OF FM GROUP INC. USE THEREOF IS LIMITED TO THE SPECIFIC PROJECT AND SITE SET FORTH ABOVE, AND MAY NOT BE OTHERWISE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN PERMISSION OF FM GROUP INC, THE ARCHITECT. THIS DRAWING IS TO BE RETURNED UPON REQUEST DOOR SCHEDULE STUD GAUGE SCHEDULE DOOR WINDOW LEGEND A1.3 MANUF. MATERIAL DESCRIPTION FINISH 15974 N. 77th STREET SUITE 100 SCOTTSDALE, AZ 85260 602.277.7877 TAG REMARKS FLOOR F-1 36"X36" LVT DKY-102 F-3 6" RED QUARRY TILE CONTACT: BRIAN ADCOCK 214.234.0511 BRYAN@ADCOCKANDCOMPANY.COM RED SURTREAD KITCHEN 1"X4" RECLAIMED WOOD BASE PAINTED BLACK ALL DINING ROOM, LOW WALLS AND HALLWAY WALLS B-3 EMSER 6"x6" TILE BASE WHITE RESTROOMS WAINSCOT AND WALLS P-1 BEHR PREMIUM PLUS FLAT BLACK PAINT MODEL #130001, #ECC-10-2 JET BLACK ZERO VOC FLAT INTERIOR PAINT ALL DINING ROOM, LOW WALLS AND HALLWAY WALLS, WITHOUT GRAPHICS P-2 KILZ ORIGINAL OIL BASED WHITE FLAT / MATTE PRIMER DO NOT USE PRIMERS MARKED LOW VOC DO NOT USE PRIMERS WITH A GLOSS SHEEN PRIMERS TO BE USED ON ALL DINING ROOM, HALLWAY AND RESTROOM WALLS TO RECEIVE WALL GRAPHICS P-3 BEHR PREMIUM PLUS ULTRA PURE WHITE #2450 EGGSHELL FINISH ALL DINING ROOM, AND HALLWAY WALLS, FOR FUTURE CONCEPT WP-1 RECLAIMED WOOD RECLAIMED WOOD SLATS SPECS AND SUPPLIER TBA ALL DINING ROOM, LOW WALLS AND HALLWAY WALLS FRP-1 QUALSERV BEVBAR FRP PANELS CUSTOM PRINTED-DICKEY'S BBQ PANEL THREE PANEL AT BEVBAR FRP-2 MARLITE FIBERGLASS REINFORCED PANEL MARLITE FRP #P100 (WHITE) PEBBLED TEXTURE GC TO PROVIDE ALL NECESSARY AND REQUIRED TRIM AND ACCESSORIES CT-1 EMSER TILE AREA GLOSSY WHITE 4.25x10 W82AREAWH0410 BOH / RESTROOM SUBWAY TILE DICKEYS@EMSER.COM THIN BRICK GENERAL SHALE PEPPERMILL AROUND MERCHANDISING RACK CT-2 WAINSCOT AND WALLS T-1 1 1/2" 3M SCOTCHAL TRANSLUCENT FILM 3630-22 BLACK OPAQUE 1 GC TO VERIFY EXISTING THRESHOLDS MEET ADA REQUIREMENTS. PROVIDE NEW OR MODIFY AS REQUIRED FOR COMPLIANCE. 1 RE: WALL TYPES; 6/A6.0 FOR PLACEMENT OF CEMENTITIOUS BACKER BOARD AT ALL QUARRY TILE BASE INSTALLATIONS 2 RE: FINISH SCHEDULE FOR APPLIED FINISHES. 3 GC SHALL FIELD VERIFY THE EXACT EXISTING SPACE CONDITIONS, DIMENSIONS, AND COLUMN SPACING PRIOR TO CONSTRUCTION AND INFORM ARCHITECT IMMEDIATELY IF ANY DISCREPANCIES ARE FOUND BETWEEN DRAWINGS AND SITE CONDITIONS. ANY CHANGES OR REWORK DUE TO UNREPORTED DIFFERENCES SHALL BE AT GC'S EXPENSE. 4 RE: PLUMBING PLANS FOR ALL FLOOR DRAIN, FLOOR SINK, AND TRENCH DRAIN LOCATIONS. 2 MIL. PRESSURE SENSITIVE FM GROUP PROJECT NO. 16-047 WOOD BASE 30451 AVENIDA DE LAS FLORES SUITE "E" RANCHO SANTA MARGARITA, CA. 92688 GC CHOICE DICKEY'S STORE # CA-1239 B-2 02.18.16 KITCHEN SUBMITTAL RED SURTREAD 0 4" QUARRY TILE BASE revision DAL-TILE no. B-1 date BASE 1 1/2" 6" QUARRY TILE 7.25"X40" LVT DKY-102 1 A2.0 FINISH FLOOR PLAN 1/4" = 1'-0" N THIS DRAWING AND ITS CONTENTS ARE THE COPYRIGHTED PROPERTY OF FM GROUP INC. USE THEREOF IS LIMITED TO THE SPECIFIC PROJECT AND SITE SET FORTH ABOVE, AND MAY NOT BE OTHERWISE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN PERMISSION OF FM GROUP INC, THE ARCHITECT. THIS DRAWING IS TO BE RETURNED UPON REQUEST FINISH FLOOR PLAN A2.0 MATERIAL DESCRIPTION FINISH NEW 15/16" GRID SYSTEM W/ 2'x4' CEILING TILES BLACK GRID AND TILES REMARKS NEW FLUORESCENT FIXTURE (2x4 or 2x2) CEILING TILES ON EXISTING CEILING GRID C-1X EXISTING FLUORESCENT FIXTURE (2x4 or 2x2) C-1X EXISTING EXISTING 15/16" GRID SYSTEM W/ 2'x4' CEILING TILES EXISTING GRID AND TILES PAINTED BLACK EXISTING CEILING TILES TO REMAIN; PATCH AND REPAIR AS REQUIRED C-2 RE: SPECS NEW 15/16" GRID SYSTEM W/ 2'x4' CEILING TILES WHITE GRID AND TILES FISSURED C-2X EXISTING EXISTING 15/16" GRID SYSTEM W/ 2'x4' CEILING TILES WHITE GRID AND TILES EXISTING CEILING TILES TO REMAIN; PATCH AND REPAIR AS REQUIRED C-3 RE: SPECS NEW VINYL CLAD WHITE GRID AND TILES GYP BOARD, 2'x4' NON-PERFORATED, LAY-IN W/ HEAVY DUTY 'T' BAR GRID SMOOTH AND WASHABLE EXISTING VINYL EXISTING WHITE TILES CLAD GYP BOARD, ON EXISTING WHITE GRID 2'x4' NON-PERFORATED, LAY-IN W/ EXISTING HEAVY DUTY 'T' BAR GRID SMOOTH AND WASHABLE TILES; REPAIR GRID AS REQUIRED NEW GYPSUM BOARD CEILING C-4 C-3X EXISTING NEW SURFACE MOUNTED FIXTURE EXISTING SURFACE MOUNTED FIXTURE NEW TRACK LIGHT MOUNTED TO CEILING EXISTING TRACK LIGHT MOUNTED TO CEILING EMERGENCY LIGHT 02.18.16 NEW SMOOTH/WASHABLE CEILING TILES ON NEW CEILING GRID C-3 FISSURED EXTERIOR EMERGENCY LIGHT C-4 RE: SPECS NEW 5/8" GYPSUM BOARD PAINTED WHITE C-4X EXISTING EXISTING 5/8" GYPSUM BOARD PAINTED WHITE EXISTING CEILING TO REMAIN; PATCH AND REPAIR AS REQUIRED C-5 RE: SPECS OPEN STRUCTURE SHERWIN WILLIAMS SW #6258 TRICORN BLACK DRYFALL FINISH EXIT SIGN, CONFIRM LOCATION REQUIREMENTS WITH FIRE MARSHAL no. NEW DIFFUSER; RE: MECHANICAL DRAWINGS SUBMITTAL RE: SPECS 0 C-1 date MANUF. 15974 N. 77th STREET SUITE 100 SCOTTSDALE, AZ 85260 602.277.7877 FIXTURE LEGEND FINISH SCHEDULE revision CEILING LEGEND ORDER HERE ARROW LIGHT RETURN AIR GRILL TYP. B.O. SOFFIT 6'-5" AFF RELOCATED RETURN AIR GRILL; RE: MECHANICAL DRAWINGS TYP. TYP. NEW EXHAUST GRILL; RE: MECHANICAL DRAWINGS EXISTING EXHAUST GRILL TO REMAIN TYP. NEW KITCHEN EXHAUST GRILL; RE: MECHANICAL DRAWINGS FM GROUP PROJECT NO. 16-047 NEW RETURN AIR GRILL; RE: MECHANICAL DRAWINGS 30451 AVENIDA DE LAS FLORES SUITE "E" RANCHO SANTA MARGARITA, CA. 92688 RELOCATED DIFFUSER; RE: MECHANICAL DRAWINGS DICKEY'S STORE # CA-1239 EXISTING DIFFUSER TO REMAIN EXISTING KITCHEN EXHAUST GRILL TO REMAIN B.O. SOFFIT 6'-5" AFF KEYED NOTES TYP. TYP. NOTE: NOT ALL KEYNOTES MAY BE USED 1 NEW EXHAUST HOOD; RE: MECHANICAL DRAWINGS 2 NEW CEILING GRID; RE: 9/A5.0 3 NEW DIFFUSER; RE: MECHANICAL DRAWINGS 4 NEW RETURN GRILL; RE: MECHANICAL DRAWINGS 5 LENS IN KITCHEN FIXTURE TO BE SHATTER-RESISTANT; RE: ELECTRICAL DRAWINGS. REPLACE OR ADD FIXTURES AS REQUIRED. 6 CEILINGS IN THIS AREA TO BE PAINTED: SEE FINISH SCHEDULE (THIS SHEET) FOR CEILING TYPES 7 NEW RESTROOM EXHAUST 8 EMERGENCY LIGHTING 9 NEW TRACK LIGHTING SEE ELECTRICAL 10 EXIT LIGHTING SEE ELECTRICAL 11 EXISTING 2x2 CEILING AND GRID TO BE REUSED, REPAIR AS REQUIRED AND PAINT. 12 EXISTING EXTERIOR LIGHTING THIS DRAWING AND ITS CONTENTS ARE THE COPYRIGHTED PROPERTY OF FM GROUP INC. USE THEREOF IS LIMITED TO THE SPECIFIC PROJECT AND SITE SET FORTH ABOVE, AND MAY NOT BE OTHERWISE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN PERMISSION OF FM GROUP INC, THE ARCHITECT. THIS DRAWING IS TO BE RETURNED UPON REQUEST GENERAL NOTES 1 REFLECTED CEILING PLAN SCALE: 1/4"=1'-0" N 1 ALL RECESSED FIXTURE TRIMS TO BE PAINTED TO MATCH ADJACENT CEILING. 2 ALL A/C GRILLS, SPEAKERS, ETC. TO BE PAINTED TO MATCH ADJACENT CEILING. 3 RE: ELECTRICAL DRAWINGS FOR ALL LIGHT FIXTURES. 4 PATCH AND REPAIR ALL EXISTING CEILINGS THAT ARE TO REMAIN AS REQUIRED. REFLECTED CEILING PLAN A3.0 15974 N. 77th STREET SUITE 100 SCOTTSDALE, AZ 85260 602.277.7877 KEYED NOTES 1 EXISTING STOREFRONT, WINDOWS, AND DOORS TO REMAIN, DOOR TO BE OUT-SWING. G.C. TO VERIFY AND CHANGE IF REQUIRED 2. FIRE LOG AND MERCHANDISING ACCENT PIECE 3 1 2" SQUARE WIRE MESH WELDED TO HINGED FRAME WITH OPERABLE LOCK 4 NOT USED 5 HANDICAP ACCESSIBLE SIGN; RE: LS1.0 6 MENU BOARD PROVIDED BY OWNER, INSTALLED BY GC 2 XXX RE: FLOOR PLAN AND SCHEDULES SHEET A1.1 FOR DOOR SCHEDULE. RE: FINISH FLOOR PLAN SHEET A2.0 FOR FINISH LEGEND. 3 A4.0 INTERIOR ELEVATIONS 3/8" = 1'-0" INTERIOR ELEVATIONS 3/8" = 1'-0" 2 A4.0 FM GROUP PROJECT NO. 16-047 3/8" = 1'-0" 4 A4.0 30451 AVENIDA DE LAS FLORES SUITE "E" RANCHO SANTA MARGARITA, CA. 92688 INTERIOR ELEVATIONS DICKEY'S STORE # CA-1239 no. 4 A4.0 SUBMITTAL 3 3/8" = 1'-0" 0 INTERIOR ELEVATIONS 02.18.16 RE: KITCHEN EQUIPMENT PLAN SHEET K1.0 FOR EQUIPMENT SCHEDULE. revision 5 A4.0 1 date GENERAL NOTES INTERIOR ELEVATIONS 3/8" = 1'-0" THIS DRAWING AND ITS CONTENTS ARE THE COPYRIGHTED PROPERTY OF FM GROUP INC. USE THEREOF IS LIMITED TO THE SPECIFIC PROJECT AND SITE SET FORTH ABOVE, AND MAY NOT BE OTHERWISE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN PERMISSION OF FM GROUP INC, THE ARCHITECT. THIS DRAWING IS TO BE RETURNED UPON REQUEST INTERIOR ELEVATIONS 1 A4.0 INTERIOR ELEVATIONS 3/8" = 1'-0" A4.0 NOTE: " SUSPENDED CEILINGS ARE SUBJECT TO PERIODIC SPECIAL INSPECTIONS DURING THE ANCHORAGE OF THE SUSPENDED CEILING SYSTEM". NOTE: PROPOSED USG SUSPENDED CEILING IS UNDER ICC ES REPORT NUMBER ESR-1222. VERTICAL HANGER WIRE ATTACHMENT SIMPSON SDS25134 WOOD SCREW SUSPENDED CEILING SEISMIC SUPPORT SYSTEM : FOR ALL NEW SUSPENDED CEILING SYSTEMS THE FOLLOWING CONDITIONS SHALL BE FULFILLED PER BLD'G CODE: FROM THE PLANE OF THE CEILING. THE VERTICAL STRUT, FASTENED TO THE MAIN RUNNER SHALL BE EXTENDED TO AND FASTENED TO THE STRUCTURAL MEMBERS ABOVE AND CEILING GRID BELOW. THESE STRUTS SHALL BE PLACED 12'-0" ON CENTER IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6 FEET FROM EA. WALL ATTACHMENT OF THE RESTRAINT WIRES TO THE STRUCTURE ABOVE SHALL BE ADEQUATE FOR THE LOAD IMPOSED. LOCAL BUILDING AUTHORITY MUST APPROVE USE OF BERC 2 SYSTEM BERC2 TILE GROUT MIN. 3/4" AT UNATTACHED WALLS SCALE: 9 A5.0 SINGLE HANGER WIRES OK UP TO 1/6 OUT OF PLUMB. COUNTER SLOPING WIRES REQUIRED WHEN GREATER 6 MAX. SLOPE THAN 1/6 OUT OF PLUMB FROM VERT. VERTICAL 1 HANGER WIRE ATTACHED WALL MOLDING REQUIREMENTS WALL WALL SPREADER BAR OR OTHER SUITABLE SYSTEM REQUIRED TO KEEP PERIMETER COMPONENTS FROM SPREADING APART MIN. 3/4" AT UNATTACHED WALLS ALTERNATE BERC 2 DETAILS 1'-0" = 1'-0" 12 GA WIRE WITH MIN. OF 3 TIGHT TURNS TOP & BOTTOM ATTACHED WALL MOLDING REQUIREMENTS BERC2 NOTE: BRACES AND ATTACHMENTS TO THE STRUCTURAL SYSTEM ABOVE SHALL BE ADEQUATE TO LIMIT RELATIVE LATERAL DEFLECTIONS AT POINT OF ATTACHMENT OF CEILING GRID TO LESS THAN 0.25 INCH FOR THE LOADS PRESCRIBED IN SECTION 13.3.1. VCT/TILE TRANSITION CONNECTION TO STRUCTURE ABOVE NOTE: STRUCTURAL ANALYSES OF THE CEILING BRACING SYSTEM FOR THE PRESCRIBED SEISMIC FORCES THAT DEMONSTRATE CEILING SYSTEM PENETRATIONS AND CLOSURE ANGLES PROVIDE SUFFICIENT CLEARANCE TO ACCOMMODATE THE ANTICIPATED LATERAL DISPLACEMENT. NOTE: ALTERNATIVELY, A SWING JOINT THAT CAN ACCOMMODATE 1 INCH OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS IS PERMITTED TO BE PROVIDED AT THE TOP OF THE SPRINKLER HEAD EXTENSION. SUSPENDED CEILING SEISMIC SUPPORT DETAIL SCALE: N.T.S. 2"X6" STL. SQUARE TUBE FRAME UNITS. EACH ADJACENT UNIT WELDED TO NEXT UNIT AT EACH HORIZONAL. 1'-7 1/2" 2'-9" 2'-7" 1'-7 1/2" 3'-4" 1'-10 1/2" 8 A5.0 1'-3" 1" THICK STAINED, SEALED WOOD PLANK SHELF 8'-5 1/2" 1'-6" 1'-3" 1'-6" 1'-6 1/2" 1'-6 1/2" 4'-6" 4'-6" PLYWOOD-PAINT PT101. MOUNT ANGLE TOP & BOTTOM. MOUNT 6" HICKORY LOGS TO PLYWOOD FRP-1 2'-8 1/2" FRP 4'-0" 2'-10" 5'-6" 2'-5" 2'-5" T.O. BUCKET SHELF 1'-6" 1'-6" 2"X6" STL. SQUARE TUBE FRAME 1 2" 1'-6" 2'-5" 8'-5 1/2" 4'-6" ANGLE IRON DOOR W/1/2" MESH PANEL ATTACHED W/HINGES WELDED TO FRAME 2'-5" 4'-6" 2'-5" 2'-5" 4'-6" 1'-6" 2"X6" STL. SQUARE TUBE FRAME 1'-6 1/2" 1'-5 1/2" 1'-6 1/2" 1'-6 1/2" 1'-6 1/2" 1'-6 1/2" 2'-6 1/2" FM GROUP PROJECT NO. 16-047 VINYL COMPOSITION TILE, RE: A2.0 FOR LOCATION OPTIONAL BERC 2 DETAIL - ATTACHED OBSTRUCTION-COUNTER SLOPING WIRES AND TRAPEZE CONDITION 30451 AVENIDA DE LAS FLORES SUITE "E" RANCHO SANTA MARGARITA, CA. 92688 OPTIONAL BERC 2 DETAIL - UNATTACHED 6 A5.0 STEEL STRAP 1" WIDE X 2" LONG X 12 GAGE MINIMUM 3 TURNS SPLAYED SEISMIC BRACING WIRE MAIN RUNNER DICKEY'S STORE # CA-1239 HORZ. 02.09.16 2" SIMPSON SDS25134 WOOD SCREW ROOF STRUCTURE SUBMITTAL 2" SPLAYED SEISMIC BRACING WIRE ATTACHMENT B. ALLOWANCE SHALL BE MADE FOR LATERAL MOVEMENT OF THE SYSTEM. MAIN RUNNERS AND CROSS RUNNERS MAY BE ATTACHED AT TWO ADJACENT WALLS WITH CLEARANCE BETWEEN WALL AND RUNNERS MAINTAINED AT THE OTHER TWO (2) WALLS. CROSS RUNNER C. DISCONTINUOUS ENDS OF CROSS RUNNERS AND MAIN RUNNERS SHALL BE VERTICALLY SUPPORTED WITHIN 8" OF SUCH DISCONTINUITIES THAT 1. LIGHTING FIXTURES WEIGHING LESS THAN 56 lbs. SHALL HAVE, IN ADDITION TO THE MAY OCCUR. REQUIREMENTS. TWO NO. 12 GAGE HANGERS CONNECTED FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK. NOTE: 2. LIGHTING FIXTURES WEIGHING 56 lbs. OR MORE SHALL BE SUPPORTED DIRECTLY SUSPENDED CEILINGS IN SEISMIC DESIGN CATEGORIES D, E & F COMPLY FROM THE STRUCTURE ABOVE BY APPROVED HANGERS. WITH ASCE 7-10 SECTION 13.5.6.2.1 AS FOLLOWS: a. ALL CEILINGS SHALL USE A HEAVY DUTY T-BAR GRID SYSTEM. GENERAL NOTES FOR STANDARD CEILING SYSTEMS: b. THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL INSTALLATION OF SUSPENDED CEILINGS TO ADEQUATELY ACCOMMODATE THE BE NOT LESS THAN 2 INCHES. APPLICABLE SEISMIC DESIGN FORCES FOR COMPLIANCE WITH CBC SECTION 808 & 1613 c. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE & ASCE/SEI 7-10 SECTION 13.5.6: CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE. CEILING INSTALLATION SHALL COMPLY WITH THE FOLLOWING REQUIREMENTS: d. THE OTHER END IN EACH HORIZONTAL DIRECTION SHALL HAVE A 34" 1. CISCA 0-2 (CEILING AND INTERIOR SYSTEMS CONSTRUCTION ASSOCIATION) AND CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO ASCE/SEI 7-10 SECTION 13.5.6.2.1 FOR SEISMIC DESIGN CATEGORY "D" STRUCTURES; SLIDE ON A CLOSURE ANGLE OR A LISTED ASSEMBLY. INSTALL PER ARMSTRONG INSTALLATION SPECS. e. CEILINGS WITHOUT RIGID BRACING MUST HAVE 2" OVERSIZE TRIM FIELD VERIFY ALL CONDITIONS AND DIMENSIONS. RINGS FOR SPRINKLERS AND OTHER CEILING PENETRATIONS. CEILING SPLAY WIRE MIN. 6" CLEAR OF SUSPENDED DUCTWORK AND EQUIPMENT. UL WALL TYPE U419 SCHLUTER-RENO RAMP (AERP-125-B90) OR EQUIVALENT VERTICAL HANGER WIRE 0 PIPE STRUT @ 12'-0" O.C. E.W. SEE SCHEDULE FOR SIZE 3 TURNS date BOLT TYP @ EA. END (4) #12 Ga. WIRES @ EA. PIPE STRUT SECURED TO MIN. RUNNER WITHIN 2" OF CROSS RUNNER INTERSECTION CEILING CLIP A. FOUR No. 12 GAUGE WIRES SHALL BE SECURED TO THE MAIN RUNNERS WITHIN 2 INCHES OF THE CROSS RUNNER INTERSECTION AND SPLAYED FLATTEN PIPE ENDS DRILL 5/8" MAX. ROOF STRUCTURE revision PIPE STRUT SCHEDULE (H) HEIGHT-FT. PIPE STRUT SIZE L 2x2x1/8" @ EA. PIPE STRUT 15974 N. 77th STREET SUITE 100 SCOTTSDALE, AZ 85260 602.277.7877 NOTE: T-BAR CEILING ASSEMBLY MUST COMPLY WITH THE FOLLOWING: CBC 803.9.1.1 UBC STANDARD 25-2 AND 25.212.1. NOTE: CONTRACTOR IS TO INDICATE ON THE FLOOR THE PRECISE FIXTURE LAYOUT PRIOR TO INSTALLATION OF THE LIGHTS TO INSURE PROPER ALIGNMENT no. "C" CLAMP (HEAVY DUTY) W/LOCKNUT @ EA. JOIST ROOF/FLOOR FRAMING FIRE LOG MERCHADISING ACCENT PIECE SCALE: 1/2" = 1'-0" 1'-7" 2'-6" 1'-7" 5'-4" B-3 4'-0" 121" 18 GA. STAINLESS STEEL TRIM WITH POLISHED OUTSIDE 1/4" RADIUS ON TOP CORNERS 121" 18 GA. STAINLESS STEEL TRIM WITH POLISHED OUTSIDE (B) FRONT VIEW THIS DRAWING AND ITS CONTENTS ARE THE COPYRIGHTED PROPERTY OF FM GROUP INC. USE THEREOF IS LIMITED TO THE SPECIFIC PROJECT AND SITE SET FORTH ABOVE, AND MAY NOT BE OTHERWISE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN PERMISSION OF FM GROUP INC, THE ARCHITECT. THIS DRAWING IS TO BE RETURNED UPON REQUEST WALL GYPSUM BOARD 1 1 2" 1 4'-0" CT-1 1 2" WALL FRAMING END B-1 3 A5.0 OFFICE MILLWORK DETAIL SCALE: 3/4" = 1'-0" B-1 2 A5.0 SCHLUTER STRIPS SCALE: 3" = 1'-0" B-3 DETAILS BEVERAGE BAR A5.0 CORNER NOTE: PROVIDE AT ALL EXPOSED CORNER OR EXPOSED WALL CONDITION. 1 A5.0 SCALE: 1/2" = 1'-0" 15974 N. 77th STREET SUITE 100 SCOTTSDALE, AZ 85260 602.277.7877 02.18.16 7 A6.0 FM GROUP PROJECT NO. 16-047 EXISTING WALL TYPES SCALE: 30451 AVENIDA DE LAS FLORES SUITE "E" RANCHO SANTA MARGARITA, CA. 92688 DICKEY'S STORE # CA-1239 no. revision SLIP TRACK DETAIL SUBMITTAL WALL LEDGER DETAIL 0 date UL WALL TYPE U420 1/2" = 1'-0" THIS DRAWING AND ITS CONTENTS ARE THE COPYRIGHTED PROPERTY OF FM GROUP INC. USE THEREOF IS LIMITED TO THE SPECIFIC PROJECT AND SITE SET FORTH ABOVE, AND MAY NOT BE OTHERWISE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN PERMISSION OF FM GROUP INC, THE ARCHITECT. THIS DRAWING IS TO BE RETURNED UPON REQUEST WALL TYPES DETAILS 6 A6.0 TYP. SNEEZE GAURD SCALE: 3/8" = 1'-0" 5 A6.0 DINING WALL FINISHES SCALE: 1" = 1'-0" 4 A6.0 NOT USED SCALE: 3" = 1'-0" 3 A6.0 SECTION AT P.O.S. SCALE: 1" = 1'-0" 2 A6.0 SECTION @COUNTER SCALE: 1" = 1'-0" 1 A6.0 SUPPORT POST DETAIL SCALE: 3" = 1'-0" A6.0 MANUFACTURER NUMBER MODEL FINISH DESCRIPTION REMARKS 1. KIMBERLY CLARK 2 92145 GRAY / BLACK LIQUID SOAP DISPENSER OR EQUAL BOBRICK 2 B-5806 x 18 STAINLESS STEEL CONCEALED MOUNTING FLANGE 18" ADA GRAB BARS OR EQUAL BOBRICK 2 B-5806 x 36 STAINLESS STEEL CONCEALED MOUNTING FLANGE 36" ADA GRAB BARS OR EQUAL BOBRICK 2 B-5806 x 42 STAINLESS STEEL CONCEALED MOUNTING FLANGE 42" ADA GRAB BARS OR EQUAL BRADLEY 2 CUSTOM BLACK IRON PAPER TOWEL HOLDER SURFACE MOUNTED, OR EQUAL BRADLEY 2 CUSTOM BLACK IRON SURFACE MOUNTED TISSUE HOLDER OR EQUAL BRADLEY 2 780-01836 SATIN STAINLESS STEEL FRAME WALL MOUNT OR EQUAL ----- ----- ----- ----- ADA UNDER-COUNTER PLUMBING GUARD COORDINATE WITH SINK MANUFACTURER BABY CHANGER 2 KB-200SS KOALA BABY CHANGER WALL MOUNTED OR EQUAL THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO IDENTIFY FACILITIES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY DISABLED PERSONS AS SET FORTH IN TITLE 24 AND AS SPECIFICALLY REQUIRED IN THIS SECTION. 2. 3. 4. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND. 6. WHEN RAISED CHARACTERS OR SYMBOLS ARE USED, THEY SHALL CONFORM TO THE FOLLOWING: A. LETTERS AND NUMBERS ON SIGNS SHALL BE RAISED 1/32" MINIMUM AND SHALL BE SANS-SERIF UPPERCASE CHARACTERS ACCOMPANIED BY GRADE 2 BRAILLE. DOOR MOUNTED SIGNAGE RESTROOM ELEVATION SCALE: 8 A7.1 1/2" = 1'-0" RESTROOM ELEVATION SCALE: 1/2" = 1'-0" 7 A7.1 RESTROOM ELEVATION SCALE: 1/2" = 1'-0" 1 LIQUID SOAP DISPENSER; 2 HANDICAP ACCESSIBLE WATER CLOSET 3 TOILET PAPER HOLDER 2 RE: FINISH FLOOR PLAN SHEET A2.0 FOR FINISHES. 4 SANITARY SEAT COVER DISPENSER 3 PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING AT ALL WALL-MOUNTED EQUIPMENT AND RESTROOM FIXTURES 5 36" HORIZONTAL GRAB BAR GB-36 4 SEE ADA1.0 FOR ACCESSORY MOUNTING HEIGHTS. 6 42" HORIZONTAL GRAB BAR GB-42 7 18" VERTICAL GRAB BAR GB-18 8 HANDICAP ACCESSIBLE SINK; RE 5/A7.0 9 WALL MOUNTED TOWEL DISPENSER 10 NEW URINAL 11 WALL MOUNTED ACCESSIBILITY SIGNAGE 12 DOOR MOUNTED ACCESSIBILITY SIGNAGE SEE DOOR SYMBOLS THIS SHEET. 13 WALL MOUNTED MIRROR 6 A7.1 TP-1 TD-1 WM-1 FM GROUP PROJECT NO. 16-047 GC SHALL FIELD VERIFY THE EXACT EXISTING SPACE CONDITIONS, DIMENSIONS, AND COLUMN SPACING PRIOR TO CONSTRUCTION AND INFORM ARCHITECT IMMEDIATELY IF ANY DISCREPANCIES ARE FOUND BETWEEN DRAWINGS AND SITE CONDITIONS. ANY CHANGES OR REWORK DUE TO UNREPORTED DIFFERENCES SHALL BE AT GC'S EXPENSE. 1 WHEN PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, RAISED LETTERS SHALL BE ACCOMPANIED BY BRAILLE. SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT. MOUNTING HEIGHT SHALL BE 60" ABOVE THE FINISHED FLOOR TO THE CENTERLINE OF THE SIGN. MOUNTING LOCATION SHALL BE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3" OF THE SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A DOOR. RESTROOM KEYED NOTES 30451 AVENIDA DE LAS FLORES SUITE "E" RANCHO SANTA MARGARITA, CA. 92688 8. GENERAL NOTES DICKEY'S STORE # CA-1239 HEIGHT OF LETTERING 5/8" MIN. TO 2" MAX. CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLE SYMBOLS ARE SPECIFICALLY REQUIRED IN OTHER PORTIONS OF THESE REGULATIONS. DOTS SHALL BE 1/10" ON CENTER IN EACH CELL WITH 2/10" SPACE BETWEEN CELLS. DOTS SHALL BE RAISED A MINIMUM OF 1/40" ABOVE THE BACKGROUND. 02.18.16 C. PICTORIAL SYMBOL SIGNS (PICTOGRAMS) SHALL BE ACCOMPANIED BY THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE BORDER DIMENSION OF THE PICTOGRAM SHALL BE A MINIMUM OF 6" IN HEIGHT. 7. 3/8" MIN. SPACING FROM BRAILLE TO ANY TACTILE CHARACTER OR RAISED SURFACE date B. RAISED CHARACTERS OR SYMBOLS SHALL BE A MINIMUM OF 5/8" HIGH. SUBMITTAL RAISED 1/32" UPPERCASE LETTERING 9 A7.1 CHARACTERS AND NUMBERS ON SIGNS SHALL BE SIZED ACCORDING TO THE VIEWING DISTANCE FROM WHICH THEY ARE TO BE READ. THE MINIMUM HEIGHT IS MEASURED USING AN UPPER CASE. LOWER CASE CHARACTERS ARE PERMITTED. FOR SIGNS SUSPENDED OR PROJECTED ABOVE THE FINISH FLOOR IN COMPLIANCE, THE MINIMUM CHARACTER HEIGHT SHALL BE 3". 5. 3'-0"x7'-0" REST ROOM DOOR WITH PUSH/ PULL PLATES CORRESPONDING GRADE ll BRAILLE LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO OF BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH-TO-HEIGHT RATIO BETWEEN 1:5 AND 1:10. 0 60" AFF 2" MIN. TYP THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE EQUAL TO COLOR NO. 15090 IN FEDERAL STANDARD 599B. revision ON DOORWAYS LEADING TO MEN'S SANITARY FACILITIES, AN EQUILATERAL TRIANGLE 1/4 INCH THICK WITH EDGES 12 INCHES LONG AND A VERTEX POINTING UPWARD AND AT THE WOMEN'S FACILITIES A CIRCLE 1/4 INCH THICK AND 12 INCHES IN DIAMETER, WHERE A UNISEX RESTROOM IS PROVIDED A COMBINED CIRCLE AND TRIANGLE SIGN SHALL BE USED AS SHOWN BELOW. THESE GEOMETRIC SYMBOLS SHALL BE CENTERED ON THE DOOR AT A HEIGHT OF 60 INCHES FROM THE FINISH FLOOR AND THEIR COLOR AND CONTRAST SHALL BE DISTINCTLY DIFFERENT FROM THE COLOR AND CONTRAST OF THE WALL. ALSO ON THE WALL ADJACENT TO STRIKE SIDE OF DOOR, MOUNT A GRADE 2 BRAILLE SIGN WITH LETTERING/BRAILLE SYMBOLS RAISED 1/32", 5/8" - 2" HIGH AT HEIGHT OF 60 INCHES. SIGNS & IDENTIFICATION no. SYMBOL DESCRIPTION WALL MOUNTED SIGNAGE TO BE LOCATED ON LATCH SIDE OF DOOR, CLEAR OF DOOR-SWING. MOUNT AT 60" TO CENTERLINE OF SIGN FROM FLOOR. 15974 N. 77th STREET SUITE 100 SCOTTSDALE, AZ 85260 602.277.7877 TOILET ROOM ACCESSORIES RESTROOM DOOR SYMBOLS RESTROOM ELEVATION SCALE: 1/2" = 1'-0" THIS DRAWING AND ITS CONTENTS ARE THE COPYRIGHTED PROPERTY OF FM GROUP INC. USE THEREOF IS LIMITED TO THE SPECIFIC PROJECT AND SITE SET FORTH ABOVE, AND MAY NOT BE OTHERWISE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN PERMISSION OF FM GROUP INC, THE ARCHITECT. THIS DRAWING IS TO BE RETURNED UPON REQUEST RESTROOM DETAILS & ELEVATIONS 5 A7.1 RESTROOM ELEVATION SCALE: 1/2" = 1'-0" 4 A7.1 RESTROOM ELEVATION SCALE: 1/2" = 1'-0" 3 A7.1 RESTROOM ELEVATION SCALE: 1/2" = 1'-0" 2 A7.1 RESTROOM ELEVATION SCALE: 1/2" = 1'-0" 1 A7.0 ENLARGED RESTROOM PLAN SCALE: 3/8" = 1'-0" A7.0 15974 N. 77th STREET SUITE 100 SCOTTSDALE, AZ 85260 602.277.7877 PULL STATION 14" MIN. PROJECTION FROM WALL URINAL TWO STATION WALL MOUNT WATER COOLERS 27" 31 5/16" 12 1/2" 2'-3" 32 7/8" 8 1/16" 6" 8" MIN. DEPTH x 30" MIN. WIDTH KNEE SPACE 6" MAX. DEPTH x 30" MIN. WIDTH TOE CLEARANCE CONTROLS MOUNTED ON WIDE SIDE OF TOILET AREA 38 3/8" 36" MIN. 48" MAX. 40" MAX. 44" MAX. 17" MAX. 6" 40" MAX. TO HIGHEST OPERABLE PART 6" 3'-3" MIN. 3'-5" MAX. 34" MAX. 29" MIN. 27" MIN. 9" MIN. 8" 19" 6" MAX. DEPTH x 30" MIN. WIDTH TOE CLEARANCE SWITCHES 8" MIN. DEPTH x 30" MIN. WIDTH KNEE SPACE THERMOSTAT date 3/4" DRYER PAPER TOWEL DISPENSER 17" FLOOR SHALL BE SLIP-RESISTANT SURFACE AND LEVEL WITH MAX 1/4" CHANGE IN LEVEL .06 STAINLESS STEEL, 1/16" RADIUS CORNERS DIE-CUT W/BURR SIDE DOWN. EMBOSSED TEXT RAISED MIN. 1/32" EMBOSSED DOMED GRADE 2 BRAILLE MIN. 1/40". EPOXY POWDER COATED BLUE BACKGROUND W/ WHITE COPY. FIRE ALARM 12" SCALE 13 MOUNTING: 30" 30" (3) TAMPER RESISTANT SCREWS & VHB 3M ADHESIVE. LOCATE CENTERED HORIZONTALLY ON THE SANITARY FACILITY DOOR AT A HEIGHT OF 60 INCHES A.F.F. MEASURED TO CENTER OF THE SYMBOL. RESTROOM SIGNS SCALE 4" EXIT BRAILLE SIGNAGE no. .04 STAINLESS STEEL, 1/16" RADIUS CORNERS DIE-CUT W/BURR SIDE DOWN. EMBOSSED TEXT RAISED MIN. 1/32" EMBOSSED DOMED GRADE 2 BRAILLE MIN. 1/40". EPOXY POWDER COATED BLUE BACKGROUND W/ WHITE COPY. .04 STAINLESS STEEL, 1/16" RADIUS CORNERS DIE-CUT W/BURR SIDE DOWN. EMBOSSED TEXT RAISED MIN. 1/32" EMBOSSED DOMED GRADE 2 BRAILLE MIN. 1/40". EPOXY POWDER COATED BLUE BACKGROUND W/ WHITE COPY. SCALE N.T.S. 4'-4" MIN. SIGN TYPE D - EXIT ID. 1'-6" MAX. 1'-4" MIN. MOUNTING: (4) TAMPER RESISTANT SCREWS & VHB 3M ADHESIVE. EXIT SIGNS 12 N.T.S. SIGN TYPE D - EXIT ROUTE ID. MOUNTING: (4) TAMPER RESISTANT SCREWS & VHB 3M ADHESIVE. 3'-10" MOUNTING: 9" MIN. 34" MAX. 54" MAX. SIGN TYPE A - TITLE 24 WOMEN ,25" ALUMINUM W/ EPOXY POWDER COATED BLUE BACKGROUND W/ WHITE GRAPHICS. 12" MAX. 1" 1" EQ 24" MAX. MOUNTING: (4) TAMPER RESISTANT SCREWS & VHB 3M ADHESIVE. LOCATE ON WAL ADJACENT TO THE LATCH SIDE O THE DOOR, 48 INCHES MIN. A.F.F. FROM THE LOWEST POINT OF BRAILLE AND 60 INCHES MAX. A.F.F. FROM HIGHEST LINE OF RAISED CHARCTERS. 6" MAX. 4" SCALE 10 N.T.S. NOT USED 3 24" 6" 60" SLIP RESISTANT SURFACE (MEDIUM BROOM FINISH) 1/8"x2" BENT PLATE WELDED TO RAIL AND1/8"x3" DIAMETER MOUNTING PLATE @ 4'-0" SCALE N.T.S. 8 EXT. DOOR REQUIREMENTS SCALE 3/4" =1'-0" 7 GRAB BAR SCALE 1/4" MAX. 1 SCALE 3/4"=1'-0" 5 10" MIN. SMOOTH, UNINTERRUPTED, DURABLE SURFACE THIS DRAWING AND ITS CONTENTS ARE THE COPYRIGHTED PROPERTY OF FM GROUP INC. USE THEREOF IS LIMITED TO THE SPECIFIC PROJECT AND SITE SET FORTH ABOVE, AND MAY NOT BE OTHERWISE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN PERMISSION OF FM GROUP INC, THE ARCHITECT. THIS DRAWING IS TO BE RETURNED UPON REQUEST BOTTOM RAIL OF DOOR 1/2" MAXIMUM SEE DETAIL 30" TO 44" DOOR HANDLE, SEE HARDWARE NOTES CHANGES IN BEVEL OF 1/4" HIGH MIN. AND 1/2" HIGH MAX. SHALL BE BEVELED WITH A SLOPE NOT STEEPER THAN 1:2. CBC-303.3 ACCESSIBLE LAVATORY MIN. 60 DEGREE SLOPE ACCESSIBLE ENTRANCE SIGN TYP. AT ALL ACCESSIBLE ENTRANCES. REFER TO DOOR SCHEDULE AND NOTES 2 6 3" = 1'-0" IF A DOOR HAS A CLOSER, THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3" FROM THE LATCH, MEASURED TO THE LEADING EDGE OF THE DOOR. 9" 1/4" TO 1/64" 48" MIN. 2"x6" BLOCKING AT WOOD STUD WALLS (OMIT BLOCKING AT MASONRY OR CONC. WALL) - TYPICAL NOTE: EXTERIOR DOOR PRESSURE CANNOT EXCEED 8.5 LBS., INTERIOR DOOR PRESSURE CANNOT EXCEED 5 LBS. US DI A R CLEAR FLOOR SPACE 6" MIN. 60" CROSS SLOPE 1:50 OR 2% MAX. 7'-6" STANDARD TOILET LAYOUT 2- 1/4"x3' EXPANSION ANCHORS AT MASONRY OR CONC. WALL 2- #10x2" SCREWS AT WOOD OR STEEL STUD WALL-TYP. NEW DOOR HEIGHT 1'-6" MAX. 1'-4" MIN. CLEAR SPACE FINISH ELEVATION TO MATCH FINISH FLOOR ELEVATION AT DOOR CL 9 1 1/2" CLR. THRESHOLD - SEE DETAIL: G 0" 5'- NIN R TU R EA 3/8" = 1'-0" GRAB BAR SHALL BE 1-1/2" MAX., OUTSIDE DIA.- TYPICAL 32" MIN. CLR. OPENING 5'-0 1/4" CLEAR FLOOR SPACE REQUIRED FOR TOILET SCALE 11 CLEAR FLOOR SPACE AT DOOR STRIKE SIDE 1'-6" 4'-8" MIN. (1420) W. WALL CLEAR FLOOR SPACE 10" OR LESS, H = 54" MAX. 10" , H = 53.5" MAX. 12" , H = 53.0" MAX. 13" , H = 52.5" MAX. 14" , H = 51.5" MAX. 15" , H = 51.0" MAX. 16" , H = 50.5" MAX. 17" , H = 50.0" MAX. 18" , H = 49.5" MAX. 19" , H = 49.0" MAX. 20" , H = 48.5" MAX. 21" , H = 47.5" MAX. 22" , H = 47.0" MAX. 23" , H = 46.5" MAX. 24" , H = 46.0" MAX. 30" MIN. 10" MAX. = = = = = = = = = = = = = = = 15" MIN. 3/4" 1" 8" D D D D D D D D D D D D D D D 6" WHEN WHEN WHEN WHEN WHEN WHEN WHEN WHEN WHEN WHEN WHEN WHEN WHEN WHEN WHEN 6" 3 ALUMINUM THRESHOLD #10 S.M. IN PLASTIC EXPANSION ANCHOR ACCESSIBILITY NOTES & DETAILS 3'-0" DOOR WIDTH TYPICAL ENLARGED RESTROOM PLAN SCALE 3/4" = 1'-0" 4 CHANGES IN LEVEL SCALE N.T.S. DICKEY'S STORE # CA-1239 CORRISPONDING REACH HEGHTS FOR GIVEN DEPTHS: 4" 1" 6" 1" (3) TAMPER RESISTANT SCREWS & VHB 3M ADHESIVE. LOCATE CENTERED HORIZONTALLY ON THE SANITARY FACILITY DOOR AT A HEIGHT OF 60 INCHES A.F.F. MEASURED TO CENTER OF THE SYMBOL. FM GROUP PROJECT NO. 16-047 3/8" = 1'-0" 30451 AVENIDA DE LAS FLORES SUITE "E" RANCHO SANTA MARGARITA, CA. 92688 MOUNTING HTS. & CLEARANCES FOR ACCESSIBILITY BY THE DISABLED SUBMITTAL 3/8" =1'-0" ,25" ALUMINUM W/ EPOXY POWDER COATED BLUE BACKGROUND W/ WHITE GRAPHICS. 14 0 SCALE SIGN TYPE A - TITLE 24 MEN (4) TAMPER RESISTANT SCREWS & VHB 3M ADHESIVE. LOCATE ON WAL ADJACENT TO THE LATCH SIDE O THE DOOR, 48 INCHES MIN. A.F.F. FROM THE LOWEST POINT OF BRAILLE AND 60 INCHES MAX. A.F.F. FROM HIGHEST LINE OF RAISED CHARCTERS. revision MOUNTING: .06 STAINLESS STEEL, 1/16" RADIUS CORNERS DIE-CUT W/BURR SIDE DOWN. EMBOSSED TEXT RAISED MIN. 1/32" EMBOSSED DOMED GRADE 2 BRAILLE MIN. 1/40". EPOXY POWDER COATED BLUE BACKGROUND W/ WHITE COPY. 7"-9" 17" 5" 10 1/2" 1" OBJECT PROJECTION FROM WALL LESS THAN 27" ABOVE FINISH FLOOR MAY PROTRUDE ANY AMOUNT T.S. COVER DISPENSER 8" WIDE x 5" DEEP PARAPHERNALIA SHELF 33" (EXCEPT @ TANK TOILETS, WHICH SHALL BE 36") 40" MAX. 36" MIN. CLR. ACCESSIBLE ROUTE SIGN TYPE B - ADA RESTROOM FOOTNOTES SIGN TYPE B - ADA RESTROOM FOOTNOTES 80" MIN. 8" 4" 1'-6" S.S. GRAB BAR 12" SEMI-RECESSED TRASH RECEPTACLE 12" MIN. OBJECT PROJECTION FROM WALL BETWEEN 27" TO 80" ABOVE FINISH FLOOR SHALL PROTRUDE NO MORE THAN 4" 6" 2" MAX FREESTANDING OBJECT MOUNTED ON POSTS OR PYLON MAY OVERHANG 12" MAX FROM 27" TO 80" ABOVE FINISH FLOOR 17"-19" 1" PROTRUDING OBJECT MIRROR MTD @ 40" A.F.F. MAX TO BOTTOM OF REFLECTING SURFACE LAV. INSULATE HOT WATER & DRAIN PIPES OPTIONAL CUP DISPENSER 02.09.16 3'-0" S.S. GRAB BAR 3'-6" S.S. GRAB BAR 3'-3" MIN. 3'-5" MAX. 2'-0" 4" ADA SIGNAGE NOTES: a. Doorways leading to men;s sanitary facilities shall be identified by an equalateral triangle 1/4" thick ith edges 12" long and a vertex pointing upward. Womens' sanitary facilities shall be identified by circle 1/4" thick and 12" in diameter. b. Geometric (Circle & Triangle) symbols on sanitary facility doors shall be centered on the door and their color and contrast shall be distinctly different from the color and contrast of the door. c. Braille Signage on side wall at no more than 12" from jamb of latch side. d. The center of all signs at 60" above finished floor. 3 TYP. ENTRANCE / EXIT DOOR SCALE 1/2" = 1'-0" 2 BOTTOM RAIL (EXT. DOOR) SCALE 3"=1'-0" 1 15974 N. 77th STREET SUITE 100 SCOTTSDALE, AZ 85260 602.277.7877 (VACANT) ADJACENT TENANT TACTILE SIGNAGE 1. A TACTILE SIGN STATING "EXIT" OR "EXIT ROUTE" AND COMPLYING WITH THE CBC 11B. SIDE OF ANY EXIT PASSAGEWAY OR EXIT DISCHARGE DOOR BETWEEN 48 INCHES AND 60 INCHES ABOVE THE FINISH FLOOR TO THE CENTER LINE OF THE SIGN. 2. CHARACTERS SHALL CONFORM TO THE FOLLOWING: A. LETTERS AND NUMBERS ON SIGNS SHALL BE RAISED 1/32" MINIMUM AND SHALL BE SANS-SERIF UPPERCASE CHARACTERS ACCOMPANIED BY GRADE 2 BRAILLE COMPLYING WITH SECTION 1117B.5.6. B. RAISED CHARACTERS OR SYMBOLS SHALL BE A MINIMUM OF 5/8" HIGH AND A MAXIMUM OF 2 HIGH". C. CHARACTERS AND BRAILLE SHALL BE IN A HORIZONTAL FORMAT. BRAILLE SHALL BE PLACED A MINIMUM OF 3/8 INCH (9.5 MM) AND A MAXIMUM OF 1/2 INCH (12.7 MM) DIRECTLY BELOW THE TACTILE CHARACTERS; FLUSH LEFT OR CENTERED. WHEN TACTILE TEXT IS MULTILINED, ALL BRAILLE SHALL BE PLACED TOGETHER BELOW ALL LINES OF TACTILE TEXT. 3. WHERE PERMANENT IDENTIFICATION SIGNS ARE PROVIDED FOR ROOMS AND SPACES, SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT. WHERE PERMANENT IDENTIFICATION SIGNAGE IS PROVIDED FOR ROOMS AND SPACES THEY SHALL BE LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE ENTERS THE ROOM OR SPACE. SIGNS THAT IDENTIFY EXITS SHALL BE LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE EXITS THE ROOM OR SPACE. 9" MIN 18" MIN 02.18.16 RESTROOMS date SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO THAT THERE IS AN 18"X18" CLEAR FLOOR AREA CENTERED ON THE TACTILE CHARACTERS 18" BOTT. OF TACTILE 60" MAX TO BOTT. OF BRAILLE GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLE IS REQUIRED. DOTS SHALL BE 1/10 INCH (2.54 MM) ON CENTER IN EACH CELL WITH 2/10-INCH (5.08 MM) SPACE BETWEEN CELLS, MEASURED FROM THE SECOND COLUMN OF DOTS IN THE FIRST CELL TO THE FIRST COLUMN OF DOTS IN THE SECOND CELL. DOTS SHALL BE RAISED A MINIMUM OF 1/40 INCH (0.635 MM) ABOVE THE BACKGROUND. BRAILLE DOTS SHALL BE DOMED OR ROUNDED. 48" MIN TO D. KITCHEN AREA TOTAL 3 OCCUPANTS 74 492 SF 1:200 3 77 SF 1:200 1 - 0 KITCHEN OTHER/OFFIC (BUSINESS) OTHER/OFFICE (BUSINESS) RESTROOMS 111 SF 1,779 SF (VACANT) ADJACENT TENANT 78 RESTROOMS NOTE: LOAD FACTORS BASED ON 2013 CBC TABLE 1004.1.2 KEYED NOTES 1 EXIT PATH OF TRAVEL 2 EXIT LIGHTING SEE ELECTRICAL DRAWINGS AND REFLECTED CEILING PLAN 3 EMERGENCY LIGHTING SEE ELECTRICAL DRAWINGS 4 EXISTING EXTERIOR EXIT LIGHTING. 5 FIRE EXTINGUISTHER G.C. TO VERIFY WITH LOCAL FIRE OFFICAL FOR FINAL PLACEMENT. (K-TYPE WITHIN 20 FEET OF HOOD SYSTEM WHERE APPLICABLE) 6 TACTILE EXIT SIGNS-SEE DETAIL ABOVE 7 OCCUPANT LOAD SIGN 8 EXHAUST HOOD, SEE MECHANICAL. 2 LS1.0 OCCUPANCY PLAN N 3/16" = 1'-0" (VACANT) ADJACENT TENANT FM GROUP PROJECT NO. 16-047 1:15 30451 AVENIDA DE LAS FLORES SUITE "E" RANCHO SANTA MARGARITA, CA. 92688 KITCHEN 1,099 SF DICKEY'S STORE # CA-1239 ASSEMBLY no. ASSEMBLY revision OTHER TOTAL OCCUPANT 1 OCCUPANCY CLASSIFICATION 0 OCCUPANT LOAD AND EGRESS ANALYSIS SUBMITTAL ASSEMBLY AREA TOTAL 74 OCCUPANTS LEGEND EXISTING EMERGENCY LIGHT EXTERIOR EMERGENCY LIGHT NEW EMERGENCY LIGHT EXISTING EXIT SIGN, CONFIRM LOCATION REQUIREMENTS WITH FIRE MARSHAL NEW EXIT SIGN, CONFIRM LOCATION REQUIREMENTS WITH FIRE MARSHAL EGRESS PATH OF TRAVEL NEW CEILING MOUNTED EMERGENCY LIGHT (ABOVE) GENERAL NOTES 1 A 1-HOUR FIRE BARRIER SHALL BE REQUIRED FOR SEPARATION BETWEEN MIXED USE OCCUPANCIES. ALL VERTICAL FIRE RESISTANT RATED ASSEMBLIES SHALL BE IDENTIFIED BY SIGNAGE LOCATED ON THE ASSEMBLY ABOVE THE CEILING. SUCH SIGNAGE SHALL HAVE LETTERS NO SMALLER THAN ONE INCH IN HEIGHT THAT STATES A FIRE RATED ASSEMBLY AND GIVING THE HOURLY RATING OF THE ASSEMBLY. SIGNAGE SHALL BE PLACED AT HORIZONTAL INTERVALS OF 8 FEET. GC TO VERIFY THAT RATING OF EXISTING DEMISING WALL IS COMPLIANT WITH ABOVE REFERENCED CODE. 2 THE BUILDING ENTRANCE SHALL BE ACCESSIBLE FROM THE PARKING LOT OR NEAREST STREET BY MEANS OF A WALK UNINTERRUPTED BY STEPS OR ABRUPT CHANGES IN GRADE, AND AT LEAST TWO ACCESSIBLE MEANS OF EGRESS SHALL BE PROVIDED WHEN MORE THAN ONE MEANS OF EGRESS IS REQUIRED BY THE BUILDING CODE. 3 ACCESSIBLE RESTROOM FACILITIES SHALL BE PROVIDED FOR THIS OCCUPANCY AS REQUIRED UNDER THE AMERICANS WITH DISABILITIES ACT. GC TO VERIFY COMPLIANCE. 4 ALL EGRESS DOORS SHALL BE SIDE HINGED SWINGING TYPES. ALL DOORS SHALL SWING IN THE DIRECTION OF EGRESS AND TWO EXITS ARE REQUIRED WHEN SERVING AN OCCUPANT LOAD OF 50 OR MORE PERSONS. ALL EGRESS DOORS SHALL BE READILY OPENABLE FROM THE SIDE FROM WHICH EGRESS IS TO BE MADE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. ALL DOORS SHALL HAVE A MINIMUM CLEAR OPENING OF NOT LESS THAN 32 INCHES. 5 THIS DRAWING AND ITS CONTENTS ARE THE COPYRIGHTED PROPERTY OF FM GROUP INC. USE THEREOF IS LIMITED TO THE SPECIFIC PROJECT AND SITE SET FORTH ABOVE, AND MAY NOT BE OTHERWISE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN PERMISSION OF FM GROUP INC, THE ARCHITECT. THIS DRAWING IS TO BE RETURNED UPON REQUEST (VACANT) ADJACENT TENANT LIFE SAFETY PLAN DOOR HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERATING DEVICES SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE. GC TO VERIFY THAT CODE COMPLIANT PANIC BARS ARE IN PLACE AND FULLY OPERATIONAL ON EXTERIOR EGRESS DOORS. 1 LS1.0 LIFE SAFETY PLAN 1/4" = 1'-0" N LS1.0