For Bath, shower, washing. エコキュート Natural refrigerant(CO2)heat pump water heater The most utilized Eco-cute for industrial use in Japan is... ITOMIC Industrial-use Eco-cute Low-cost and Eco-friendly heat pump water heater. Registered as specified procurement items in the Law on Promoting Green Purchasing. 「日本イトミック」 Prizewinning The products are subject to change in specifi cations for improvement without notice. Received the 9th Award for Power Load Leveling Equipment and Systems from the chairman of the Heat Pump & Thermal Storage Technology Center of Japan. ITOMIC Ind has Registered as specified procurement items in the Law on Promoting Green Purchasing. Storage tank unit 3,000ℓ Heat pump unit Remote controller ITOMIC brand Eco-cute is the first of its kind sold in the world. Itomic has know-how accumulated for half a century as a dedicated manufacturer of water heaterswe offer a wide variety of hot-water supply heaters. 【Kitchen】 Dish washer Wash bas Floor washing Taps Shower Bathtub 【Bathroom】 Kubota Corporation Keiyo Factory Nippon Express Co., Ltd. The Asahi shimbun Company 1 Trest-Inn Tamachi Hosei University Junior and Senior High School ustrial-use Eco-cute extensive experience in supplying hot water. sin 【Rest room】 Sales record of Eco-cute ITOMIC Ind Industrial-use strial se EcoEco cute is the most utilized Ecocute for industrial use in Japan. 【Business category】 Nursery homes Offices Factories Education facilities Public facilities Hotels Dormitories Restrants...and more! Other Dormitories Nursery Nurs hom homes Hotels t l Offices Public ublic bli Facilities A ir Eco-cute heats water with natural air. Education Ed ducation ti Facilities Fa t Factories Fact Jan. 2008 System fl ow → P.3 ∼ 4 Customers’success stories in achieving CO2 and cost reductions using Eco-cute see Nursery home Mominoki・Suginami Ajigaura Hot Spring NOZOMI Nursery home Livein Sakura 2 Musashi Institute of Technology P.8 Key features This is why many customers choose ITOMIC Industrial-use Eco-cute. Low-running cost Bring water to 300yen High temperatures 90℃ Details → seeP.15 Plenty of hot water for various use. Operation cost per day (Using industrial electricity of Tokyo Electric Power Company, ten hours per day, 90 ℃ , 3 tons, which is equivalent to 60 ℃ , 4.5 tons) Safe and Easy operation No combustion. Out of boiler code code*. (*Note that the regulations regarding boilers vary in countries of use.) Storage tank unit 3,000ℓ(500ℓ×6) Eco-friendly Heat pump unit 1 1700 Reduction in CO2 emissions 1/6 approx Compared with a gas boiler, it can drastically reduce CO 2 emissions if changed from other t ypes of water heaters. Details → seeP.16 Global warming potential compared with new refrigerant. System flow 0 Ozone-Depleting Potential Supply hot water Storage tank unit 1. Absorb heat from the air and transfer it to the heat exchanger (for air), then deliver the heat to refrigerant. Heat pump unit 2. Warmed up refrigerant is pressed by compressor and becomes hotter. 3. Heat of refrigerant is transferred to water by a heat exchanger (for water) to boil water. 4. The refrigerant that loss heat is sent to the heat exchanger (for air) again. A High Hot tempera- water (90℃) ture ② ① Absorb heat from the air Heat excahanger (for air) CO2 refrigerant cycle ④ Low temperature B ③ Heat excahanger (for water) Heat up water C Water A:Compressor, B:Expansion valve, C:Circulation pump 3 ※Construction b Environmental performance depending on refrigerant type The refrigerant used in Eco-cute is a natural resource of CO2 (R744). So it is eco-friendly and no collection is needed on disposal. You can make an appeal for a more eco-conscious facility. ODP ※1 Refrigerant GWP ※2 CFC Refrigerant R12 1 HCF Refrigerant R22 0.055 1,700 0 1,700 0 1,300 0 1 HFC Refrigerant R410A 〃 R134A Natural Refrigerant R744 (CO2) Necessity of collection 8,500 Yes No These values are based on our estimation. ※1:ODP=Ozone Depletion Potential. ※2:GWP=Global Warming Potential. Unique operation mode Eco-cute has two unique operation mode, which reduces unnecessary running. Details → seeP.15 Accessory: Remote control ITOMIC Industrial-use Eco-cute includes one remote control per unit. Name Display contents, application ① Normal operation: Current water temperature (℃ ) is shown. ① LCD Abnormal condition: The error number is shown. ② Operation lamp ③ Start/Stop/Reset switch ② Normal operation: Orange lamp is lit. Abnormal condition: Orange lamp is flashing. Normal operation: It is used to turn the operation on/off. ④ ③ Abnormal condition: After error cause is cleared, push the button to reset the error display. ④ Remaining water Remaining water volume in Eco-cute is shown by the lamps. indicator lamps Refer to page 14,“Remote control installation.” Usage Boil water ※ ※ ※ R ←Supply water Bathroom Kitchen by customers 4 Rest room To select the best Eco-cute Standard model; Heat pump unit and 3,000 liter storage tank unit. The standard model for the ITOMIC Industrial-use Eco-cute consist of one heat pump unit, one 3,000 liter storage tank unit, and one remote control. However, depending on the hot-water supply conditions of the facility, customization and combinations with other water heater systems are available. Here are the some tips for selecting the best products. Storage tank unit Heat pump unit To maximize the performance; Do you need smaller volume of hot water? Do you need larger volume of hot water? Change to a smaller tank. Add heat pump units and storage tank units. Combine large capacity heater-equipped open-type storage tank. Do you want to reduce initial cost? In case the hot-water supply load varies... Reuse existing water heater equipment if available. Combine cost-effective storage tanks or other water heaters available. Use boilers that combust gas or fuel oil together. Do you prefer a more eco-friendly system? Use solar electrical generators or solar hot-water systems together. These are just examples. E ach has ad vant age s and disadvantages. Feel free to contact us for consultation. Options → see P.11 Product demonstration tour We organize tours for product demonstration. We'll show you our head factory (Tokyo, Japan) and our customer's actual sites where Eco-cute is in use. You can see the firsthand effectiveness. For details, feel free to contact us. 5 System composition examples Standard system Installation example → see P.14 This is a standard system composed of an Eco-cute heat pump unit and a storage tank unit only. When a large volume of hot water is required, multiple units of Eco-cute are connected in parallel or installed in each hot-water supply area. Eco-cute When multiple units of Eco-cute are installed, an optional control function for multiple units can be built if desired.(→ See P.11 "Change in specifications") Circulated hot water system To prevent undesirable temperature drop at the supply outlet. Our electric in-line heater EIL can be added as a booster to circulation process, or changing the system to Heat-up circulation specification is another option. Circulated hot water system with EIL The heat-up circulation specifi cation does not need an EIL. Circulated water (return) comes into the Eco-cute. (→ See P.11) In case the circulation load is low… Heat-up circulation specifications is recommended. • In case the circulation load is high… The electric inline heater (EIL) is recommended. Eco-cute 循環系統 • EIL EIL Boiler combination system Hot-water supply load → Because variation of demand occurs from season to season and/or weekdays, Eco-cute alone may not be able to supply necessary quantity. If that is the case, we recommend this system to cover the deficiency, where Eco-cute as primary supplier and boilers to supplement. In addition, adding an Eco-cute system into an existing water heater system can lower the operating cost of the entire system. Boiler Eco-cute + The boiler starts operation and cover the defi ciency. When stored hot water runs out... Boiler Eco-cute Time → 6 ITOMIC Industrial-use Eco-cute Meets your needs Cost reduction ▶ Eco-cute is a high efficiency water heater using minimum of electric power. ▶ Electricity is energy with little fluctuation in price. ▶ The initial cost will decrease when reusing existing equipment or in combination with storage tanks and combustion type boilers. ▶ Because Eco-cute is out of boiler code*, maintenance cost can be held down. (*Note that the regulations regarding boilers vary in countries of use.) ▶ Unique energy-saving operation mode reduces unnecessary running. Eco-friendly and safe facilities ▶ CO2 emission are much less than from combustion type, which is effective in achieving the target of CO2 emission reduction. ▶ Only the Eco-cute CO2 refrigerant is eco-friendly because both the global warming potential and ozone depletion potential are minimal. ▶ Different from boilers that burn fuel, Eco-cute emits no exhaust gas and keeps the air clean. ▶ Because no ignitable fuel is used, facilities are safe. ▶ CO 2 refrigerant in Eco-cute has no harm on the environment even during the production and disposal process. Elimination of time and effort for installation and maintenance ▶ Length of pipes can be longer, which reduces design restraints. ▶ Reuse of existing equipment in combination with boilers reduces the effort of design, installation, and maintenance. ▶ We have various types of electric water heaters from table-top to heavy volume applications. Therefore, all water heaters in a facility can be prepared at the same time. 7 Customer review Kubota Corporation Keiyo Factory The welfare building of our institute had used LPG as a water heater fuel for the bathrooms and lavatories for a long time. However, the Rationalization in Energy Use Law imposed CO 2 emission reductions, which forced us to switch to water heater equipment that could effectively and immediately reduce CO2 emissions. During renovation, we installed ITOMIC Eco-cute, which was reportedly more effective in reducing CO2 emissions than other water heater equipment. And now, two years after installation, the remarkable advantage that we obtained by having selected Eco-cute appears in annual CO2 reduction reports. It contributes to“operations with concern for preserving the natural environment”prompted as part of the Kubota Group Environment Char ter. ( Mr. Sasaki, Environmental safety group leader) The Asahi shimbun Company From an environmental viewpoint, and in a position to cooperate with reductions in carbon dioxide emissions, we decided to switch from the existing steam boiler to the electric ITOMIC Eco-cute and thus executed the renovations. The Asahi shimbun Company believes this activity plays a role in preventing global warming. In addition, safety is improved because Eco-cute is not a boiler. (Mr. Someya of Asahi Tatemono Kanri Co., Ltd.) NIPPON EXPRESS CO., LTD. Our Shinagawa Trunk Room offers cutting-edge storage rooms featuring base-isolation construction and perfect air conditioning. Temperature and humidity are fully controlled to secure customers’valuable belongings. We focus on environmental conservation efforts, including employment of eco-packing materials and support the encouragement campaign of the Team-6 % Committee, ”1 person, 1 day, 1 kg of CO2 emissions reduction." As part of this activity, we installed eco-friendly and small CO 2 emit ting I TOMIC Eco cute in the Shinagawa Trunk Room. We expect that it will largely contribute to reductions in CO 2 emissions, whose importance is increasing. (Accounting section personnel) 8 Hosei University Junior and Senior High School In order to bring out the full energy-saving effect, this institute selected equipment based on an energy-saving plan made by an energy service company. The construction was completed recently, and the energy-saving effect has not been concretely measured yet. However, we are not concerned because the ITOMIC Eco-cute brings out the energ y-saving ef fect more than gas and oil boilers. (Mr. Kaneko of Shinryo Corporation) Trest-Inn Tamachi The primary target on opening in 2003 was energy cost reduction. ITOMIC Eco-cute conformed to the idea. The system uses nighttime electricity at the lowest energy price rate. The added value of easy operation led to the decision to install the equipment. As for the installation effect, we appreciate running cost lower than that for fuel gas, which is in the initial plan. In addition, we consider it an advantage that the safety of our guests is ensured, especially in the hotel business where safety is essential. (Mr. Tanaka, Manager) Ajigaura Hot Spring NOZOMI The installation of two ITOMIC Eco-cute was triggered by a proposal from Tokyo Electric Power Company, Ibaraki Branch, including equipment maintenance and the reduction in running cost, about five years after opening the facility. The plan and the actual operation are as follows: on weekdays Eco-cute heats water until the evening and the boiler starts operation after the hot water runs out. This system meets our demand and contributes to the reduction in operating cost. Now we have a plan to expand the facility. On this occasion, Ecocute will be additionally installed and both the hot water made by eco-friendly Eco-cute and the hot springs ultra-deep water welling from underground of 150 4 meters will satisf y guests with the pleasant spa. (Mr. Masaki Kurosawa, company executive) 9 Nursery home Mominoki・Suginami Our first priority is resident's safe, comfortable life and that all facilities employ safe, reliable, and eco-friendly All electrification. On opening in March 2006, we selected earth- and human-friendly ITOMIC Eco-cute as water heater equipment.“Human-friendly”means safety. Ecocute that does not use fire brings no anxiety so that we can offer our basic ideal of a safe and reliable life to our residents.“Earth-friendly”includes the carbon dioxide emission reduction eff ect. In addition, to boil water using relatively cheap night electricity (60 % discount off the daytime) remarkably reduces running cost compared with gas and oil systems. Installation of this product has realized our aim,“earth- and humanf r ie n dl y r e sid e n c e su r r o u n d e d by nature that let us sense the four seasons.”(Mr. Kurahashi, section manager of the Planning Department, Toden Life Support Co., Ltd.) Nursery home Livein Sakura From the viewpoint that employment of the All electrifi cation system would bring relief to residents and would increase added value to the entire facility, we decided to install ITOMIC Eco-cute. Hot water from Eco-cute is used in the kitchens and bathrooms. It is popular among residents that plenty of chlorine-free hot water is available due to the water storage type. (Mr. Ito, institution director) Musashi Institute of Technology The Yokohama Campus of Musashi Institute of Technology (Faculty of Environmental and Information Studies) became the first educational institution in Japan to acquire the international environmental standard ISO14001 certification in 1998. The facility (commonly-called“Eco campus”) and the attached junior and senior high schools, which were renovated in 2007, are equipped with a variety of different kinds of state-of-the-art eco-conscious technologies. The key factors that made us decide to employ ITOMIC Ecocute, as one of above equipment, were not only environmental consideration but also the lowest long-term running cost compared with gas and oil boilers, CO2 emission reduction, and safety to achieve reliable schools for students. Now we receive the full advantages of selecting the All electrification system and Eco-cute with eco-friendly and energysaving technologies. (Mr. Shiba, manager of the General Affairs Department, corporate office ) 10 Specifications and Options Performance specification Specifications Conditions ※3 Power source Three - pahse 50Hz Installation Outdoor Setup temperature 90 ℃ ※1 Heating ability 21.3kW 26.3kW Hot water fl ow volume 70 ℓ/ min Water volume 3.8ℓ/ min 7.8ℓ/ min Refrigerant pressure High-pressure side 15MPa Low-pressure side 8MPa Power consumption 7.1kW 6.9kW Operation current 25.2A Decompression valve (Arranged by customer:170kPa → see P.13) Biggest stating current 207A 190kPa Noise level ※4 54db Pressure relief valve Compressor A Item Type Half closed reciprocating compressor Motor type Three-phase inducing motor Rated output 8.4kW Crank case heater 100W Fan Propeller fan 110W × 2units Pump Seal less AC200V-100W Air heat exchanger Forced convection cross fin Forced circulation dual tubes Protection devices Compressor bursting board, High pressure switch, Low pressure switch, Overcurrent relay (Compressor, fan, pump) R744 (CO2) Functions Learning function, Seasonal mode Accessories ※2 Remote control Color Ivory white 24.7A ※3: Condition A:Outside temp DB=7 ℃ ,WB=6 ℃ ,Hot water inlet =9 ℃ /outlet=90 ℃ ConditionB:Outside temp DB=16 ℃ ,WB=12 ℃ ,Hot water inlet=17 ℃ /outlet=65 ℃ ※4: 1m apart from the unit and 1.5m high. Hot water heat exchanger Refrigerant B Storage tank unit (3,000ℓ) Heat pump unit ※1:90 ℃ mode. ※2:→ See P.16 Options Change in storage volume of storage tank unit 2,310 1,560 1,560 CHP-2500U(2,500ℓ) 1,560 CHP-2000U(2,000ℓ) It is possible to change the dimensions shown below. Feel free to contact us for consultation. 2,310 920 1,560 CHP-1500U(1,500ℓ) 920 920 CHP-1000U(1,000ℓ) 920 CHP-500U(500ℓ) Change in specifications Salt resistant and High salt resistant specifications Heat-up circulation specifications These specifications include a coating applied to the exterior and main components according to the Japan Refrigeration and Air Conditioning Industry Association Standard (JRA9002), which prevents sea salt particles fl owing on salt breezes from adhering to the equipment and causing corrosion. In high salt resistant specifi cations, the number of coating applications (thickness) is more than that in the salt resistant specifications. These specifications ensure that the hot water is circulated to prevent heat discharge in the plumbing. Select this to build a circulated hot water system with initial cost reductions where the hot-water supply load is not high. (However, if the hot-water supply load is high, consider separately provided electric in-line heater EIL instead of this system.) Antifreeze specifications Multiple units control specifications These specifi cations include antifreeze band heaters installed in the main parts of the heat pump unit and the storage tank unit to prevent plumbing damage due to freezing in midwinter. (The heaters automatically turn on when the outside temperature drops below 5 ℃ .) When more than one Eco-cute is installed in parallel and operated at the same time, variations in the hot-water supply condition of each unit (drift fl ow) will be generated. The multiple units control specifi cations only need wiring between the Eco-cute units. The remaining volume of hot water in each unit is monitored, and the hot-water supply is automatically adjusted to resolve the variation. For high pressure specifi cations (0.49 MPa), contact us for consultation. Separately provided items (Contact us for their price.) This figure is for indoor type. Heat pump unit Vibration-proof stand Snow protection hood Distant-control system 11 Electric in-line heater EIL Dimensions Remote control (70) Air outlet Air inlet (20) R2.5 (83.5) (120) A :Hot water outlet Rc3/4 (20A) (A' plug set with cover) B :Water inlet Rc3/4 (20A) (B' plug set with cover) C :Anchor bolt set hole 4- φ15mm D :Air heat exchanger room drain Rc1(25A) E :Cable connection F :Outside signal connection G :Power supply intake H :Water drain during operation Rc3/4(20A) I :Operation check window(Front) J :Control panel position(Front) K :Low pressure gauge L :High pressure gauge (14.3) Heat pump unit (貯湯量) 100% 75% 60% 40% 25% 運転中 運転 停止 リセット 10% R2.5 (φ8.5) Remote control chord (6.5) (9) Installation clearance (mm) Air outlet Air inlet Storage tank unit(3.000ℓ) ① ② ③ ④ ⑤ ⑥ ⑦ Tank drainage ⑧ Hot water connection Supply water Rc3/4 (20A, to Heat pump unit) ⑨ Relief valve check window Supply water connection Hot water inlet Rc3/4 (20A, from Heat pump unit) Anchor bolt setting hole 6-φ22mm Temperature sensor connection line inlet Temperature sensor connection box Capacity (ℓ) 3.000 2,500 2,000 1,500 1,000 500 12 Dimensions(㎜) W D H 2,310 1,560 2,175 2,310 1,560 2,175 1,560 1,560 2,175 2,310 920 2,165 1,560 920 2,165 920 920 2,165 Piping connection ③⑧ ① Rc1 1/4 Rc1 Rc1 1/4 Rc1 Work procedures (abstract) For details about installation, refer to separate Technical Manual. Installation location Install the units where cold air from the heat pump unit outlet or operation noise do not annoy neighbors and consider sound insulation measures. The following space is needed for maintenance inspections. If the space is less than the following, maintenance may be impossible. Be sure to maintain more space than the following when designing. Front 500mm ѳ3,000mm 500mm Front 900mm 700mm 900mm 700mm ѳ2,500mm 700mm 500mm Top view ѳ2,700mm ѳ3,300mm Front view 3m The heat pump units are to be installed outdoors. The distance between the heat pump unit and the storage tank. [In case they are installed at the same level] Recommendation is 5 m in direct distance (max. 30 m) [In case one is installed on top of the other] In case the heat pump unit is on top and the storage • tank is on the bottom: real height is 3 m (total plumbing length is 5 m or less) • In case the storage tank is on top and the heat pump unit is on the bottom: real height is 7 m (total plumbing length is 10 m or less) Water quality Use tap water for Eco-cute. If well water is to be used, be sure to contact us for consultation. Items arranged by customers When plumbing, pressure reducing valves, vacuum breakers, mixing valves, and motor valves are needed. Customer is responsible for providing them according to the water heater system. (Table on the right shows our recommendation.) Water supply line Hot water supply line Item Model No. Pressure reducing valve RD-31N Vacuum breaker VD-5N Mixing valve JRG3400,3410 Motor valve BM-7S Manufacturer VENN Co., LTD. About these items, please contact to the manufacturer. 13 Installation example Heat pump unit Storage tank unit Thermistor cable(12 core) Automatic air vent valve Hot water outlet Hot water inlet Water inlet Hot water outlet Remote control cable (Balanced type shield wire) Water outlet Distant-control cable Drain outlet (Open constantly) R Water inlet Water supply Drainage Drain outlet (Open constantly) Floor drain Pressure reducing valve Precautions Water supply plumbing 1. Feed water pressure is recommended as 0.2 to 0.3 MPa on the primary side. 2. Use stainless steel or copper pipes for plumbing. 3. Conduct heat insulation work to prevent condensation on the plumbing. 4. If water is expected to freeze, implement antifreeze measures. Hot-water supply plumbing 1. Use heat resistant plumbing material such as stainless steel and copper. 2. Conduct heat insulation to prevent accidents and heat radiation. 3. When hot water is supplied downwards from the storage tank, install atmosphere open pipe or vacuum breakers to prevent negative pressure generation. 4. When driving a pipe into the storage tank directly, do not to apply force to the neck portion. Drain plumbing 1. Do not install valves at the drain outlet and the heat pump unit drain port (air heat exchange drain). Be sure to conduct indirect drainage treatment instead. 2. The storage tank drains high temperature water. Use heat resistant plumbing material. Remote control installation 1. Only one accessory remote control should be installed for one heat pump unit. In case the remote control is installed far from the heat pump unit, extrinsic influence such as noise may cause malfunctions. Implement the necessary measures to avoid any influence from the conduit work or route confirmation. (In particular, do not approximate or parallel the master electric cable to the operation cables.) Do not exceed the maximum cable length of 50 m. 2. Use shielded cables for the remote control line and be sure to ground one end of the shielded cables. 14 Reference data Electricity contract and running cost (Japan domestic) Electricity contract Eco-cute utilize relatively cheap Industrial thermal storage adjustment contract, and hot water equivalent to 4.5 tons at 60 ℃ * cost 300 yen per day. Moreover, Industrial All electrification contract enables further running cost reductions. (* 3 tons at 90 ℃ conversion) Basic contract Industrial thermal storage adjustment contract If the operation time of a thermal storage type water heater system shifts from daytime (8:00 to 22:00) to nighttime (22:00 to 8:00), this contract results in a 60 % discount on the electricity bill. ITOMIC Industrial-use Eco-cute is usually operated under this contract. Calculation: Discount of the thermal storage adjustment contract = Electricity consumption for discount x rate in daytime x discount rate (approx 60 % ) Additional contract Industrial All electrification contract After holding the Industrial thermal storage adjustment contract, if your heat source in the kitchen and air-conditioners are All electrification, you can additionally hold the contract and receive a 7 % discount. Calculation example ● Running cost per month without a discount (6.9kW ×10h×30days)×@ ¥12=¥24,840 ¥24,840 ● In case of Industrial thermal storage adjustment contract Discounted amount = (6.9kW ×10h×30days)×@ ¥12×60 % =¥14.904 Running cost per month=24,840−14,904=¥9,936 ¥9,936 Running cost per day =9,936÷30days =¥331 ● In case of Industrial thermal storage adjustment contract + All electrification contract Discounted amount =9,936×7 % =¥695 Running cost per month=9,936−¥695=¥9,241 Running cost per day =9,241÷30days =¥308 ¥9,241 0 5000 10000 15000 20000 25000 These values are based on our estimation. Running cost comparison High efficient Eco-cute results in small energy consumption and low running cost. In addition, because the electricity bill is little affected by price hikes in materials, it can be operated and the cost remain stable. High efficiency results in small energy consumption. Electricity is stable in price rate. Industrial thermal storage adjustment contract makes large discount. * Note: The annual running cost are diff erent from above electricity contract because the calculation conditions are diff erent. ¥848,350 ¥848,350 ¥658,125 ¥658,125 ¥464,740 ¥464,740 Equipment type Item ¥ ¥140,830 140,830 Itomic industrial use Eco-cute Gas boiler Coal oil boiler Electric water heater Energy consumption ratio 1 6.0 4.7 3.3 Annual running cost ¥140,830 ¥848,350 ¥658,125 ¥464,740 Annual balance --- + ¥707,586 + ¥517,334 + ¥323,909 Energy price rate @¥5/kWh @¥95/㎥ @¥65/ℓ @¥5/kWh Consumption amount (annual) 28,166kWh 8,930 ㎥(N) 10,125ℓ 92,948kWh These values are based on our estimation. Calculation conditions: One-year daily usage with All electrifi cation and nighttime thermal storage. Hot-water supply load: Average fed water temperature in Tokyo area = 17 ℃ , boiled to 90 ℃ , yearly average temperature in Tokyo area (DB) = 16 ℃ , COP = 3.3. Boiler effi ciency: 90 % , Energy price rate: estimated, annual load: 365 days x (90 ℃ - 17 ℃ ) x 3000 L = 79,935,000 kcal. 15 CO2 emission comparison Electricity does not burn fuel so CO2 emissions are small. Energy consumption is small so CO2 emissions are small. 71.2 72.1 48.7 22.5 Equipment type Item Itomic industrial use Eco-cute Gas boiler Coal oil boiler Heavy oil boiler Amount of CO2 emissions 22.5 48.7 71.2 72.1 Amount of heat released 88.8MJ/h 45MJ/N㎥ 35.6MJ/ℓ 39.1MJ/ℓ Equipment efficiency 100 % 85 % 85 % 85 % CO2 emission factor ※ 0.3kg-CO2 /kWh 2.1kg-CO2 /N㎥ 2.5kg-CO2 /ℓ 2.7kg-CO2 /ℓ CO 2 emissions are compared with the water heater equipment using other energy, which operates the same heating performance as ITOMIC Industrial-use Eco-cute. CO2 emission factors are specifi ed values of the Ministry of the Environment in 2007. Other values are based on our estimation. Calculation conditions: Supplied hot water 90 ℃ , outer temperature 16 ℃ , 10-hour operation. Heating capacity = 88.8 MJ/h x 10 h = 888 MJ. CO 2 emissions = 0.3 kg/kWh x 7.5 kW x 10 h = 22.5 kg. * CO2 emissions when one energy unit (m2, L, kWh) is consumed. Operation mode (Detail) Seasonal mode This is an energy-saving function; operation pattern per weekday has been monitored for the past one month (four weeks) and the required volume of hot water and operation time are calculated, which prevents unnecessary operation and water temperature decreases due to natural heat radiation. (This function must be set by our service personnel.) As contrasted to normal 90 ℃ operation mode, this mode varies operation temperature according to the outside temperature. Using this mode in summer, when not as much high temperature water is required, reduces unnecessary boiling and warming operations. 100 Hot water temperature(℃) Culclated Monitored hot water volume(ℓ) hot water volume(ℓ) Learning function 90 90 80 88 84 80 70 90℃ mode 76 72 60 68 64 60 50 Seasonal mode 40 30 20 10 0 -15 Mon Tue Wed Thu Fri Sat Sun -10 -5 0 5 10 15 20 Outside temperature(℃) After calculation, the following modes are available. (1) Electricity reduction operation (2) Natural heat radiation reduction operation (3) Combination of above-mentioned (1) and (2) The operation mode is set as you like. 16 25 30 35 40 FAQ Here are frequently asked questions from our customers. Q1 Are any hygiene measures against Legionella required? A1 Legionella is sterilized over 60 ℃ . Because this unit stores water at over 60 ℃ , the bacteria does not develop. Q2 Is water boiled by Eco-cute suitable for drinking? A2 Be sure to boil water again with kettles before drink. Q3 How loud operation noise is? A3 It is 54 dB (at point of 1 m distant, 1.5 m high). Q4 How about equipment durability? A4 Legal durable years in Japan are 15 years. However, note that it depends on actual operating conditions and environment. Q5 How long is the distance between the heat pump unit and the storage tank? A5 When installed at the same level, the recommendation is 5 m in direct distance (max. 30 m). In case one is installed on the top of the other, it depends on the installation method. In case the heat pump unit is on top and the storage tank is on the bottom: real height is 3 m (total plumbing length is 5 m or less) In case the storage tank is on top and the heat pump unit is on the bottom: real height is 7 m (total plumbing length is 10 m or less) Q6 Is it possible to install the heat pump units indoors? A6 Install them outdoors. Heat exchange failure may occur, which results in lower performance. For questions other than the above, feel free to contact us. 17 Questionnaire Sheet This sheet will be used to provide you with the best energy-saving water heater equipment. Please fill in the following items and fax the information to us. Contact name Country Address TEL/FAX/E-mail Construction phase Address of the building Scale of the building New building Renovation Total floor area Reconstruction ㎡ , [ On the ground stories, basement stories ] Application of hot water Operating time : ∼ : Number of people Volume of hot-water usage ● Kitchen ● Bathtub Hot-water supply conditions ● Shower ● Wash basin Electric water heater In case of renovation, about current water heater equipment Boiler Other[ Manufacturer, Model Current fuel ] Used time Gas Oil( heavy fuel oil / coal oil ) Other information FAX to Nihon ITOMIC Co., Ltd Eco Products Department FAX+81-3-3621-2130 18 years Nihon ITOMIC Co., Ltd Eco Products Department Itomic building 5-11-3, Narihira Sumida-ku, Tokyo, 130-0002, Japan TEL+81-3-3621-2141 / FAX+81-3-3621-2130 http://www.itomic.co.jp/english/ 台灣地區總代理 乘陽科技有限公司 Tel : 02 29270407 Fax : 02 29209403 www.co2hp.com Cell Phone : 0933034124 '08.03-1-1-0.5 I