marine and offshore cables

Transcription

marine and offshore cables
5/2016
MARINE AND
OFFSHORE CABLES
MARINE AND OFFSHORE CABLES • INDUSTRIAL CABLES • OPTICAL FIBRE CABLES • FLEXIBLE CABLES
Contents
Helkama – a true specialist in marine cables..3
Approvals ..........................................................3
0,6/1kV cables
LKM-HF..............................................................4
LKMM-HF ..........................................................8
LKSM-HF..........................................................10
LKMSM-HF .....................................................14
LKAM-HF..........................................................16
LKEM-HF..........................................................18
EMC cables
LKSM-EMC ......................................................20
LKSM-EMC-FRHF.............................................24
RFE-EMC..........................................................28
RFE-EMC(i) ......................................................30
RFE-EMC-FRHF NEW .......................................32
RFE-EMC-FRHF(i) NEW....................................34
1,8/3kV cables
LKSM-VFD .......................................................36
0,6/1kV FR cables
LKM-FRHF........................................................38
LKMM-FRHF NEW............................................42
LKSM-FRHF .....................................................44
LKMSM-FRHF NEW .........................................48
LKAM-FRHF .....................................................50
250V cables
LKM-HF ...........................................................52
LKSM-HF..........................................................54
LKAM-HF .........................................................56
RFE-HF.............................................................58
RFE-HF (i) ........................................................60
RFA-HF.............................................................62
RFA-HF (i) ........................................................64
Marine cable factory in Kaarina, Finland.
Marine cable factory in Shanghai, China.
250V FR cables
LKM-FRHF .......................................................66
LKSM-FRHF ....................................................68
LKAM-FRHF ....................................................70
RFE-FRHF.........................................................72
RFE-FRHF (i) ....................................................74
RFA-FRHF ........................................................76
RFA-FRHF (i)....................................................78
Heat resistant cables 120°C
LKSM-SHF2 120°C 0,6/1kV .............................80
LKSM-SHF2 120°C 250V .................................84
RFE-SHF2 120°C 250V.....................................86
RFE-SHF2 (i) 120°C 250V ................................88
Optical fibre cables
FXMSU.............................................................90
FXMMS ............................................................92
Cabled optical fibres characteristics.................94
Technical information
General information .........................................96
Bending radius .................................................97
Diameter tolerance ...........................................89
Core identification ............................................97
Current rating...................................................98
Short circuit current.........................................99
Short time duty ..............................................100
Voltage drop...................................................101
Subject to change without prior notice. See latest updates on
our webpage www.helkamabica.com
3
Helkama is specializing in development and
production of marine and offshore cables. Our
experience in this field goes back more than
fifty years. Our high technical quality has been
achieved by continuous development work
supported by our clients. In this catalogue we
proudly present our most comprehensive range
of marine cables.
We have chosen to produce only halogen-free
cables. They remarkably improve the fire safety
of the ships by not emitting toxic burning fumes
or thick smoke. In addition no corrosive gases
damaging the ship and its equipment are
emitted in case of a fire. Using the latest
technology we have been able to reduce cable
weight and size to a minimum and still maintain
quality as well as enabling easy and fast
installation. The halogen free range of cables
includes both flame-retardant (IEC 60332-3)
and fire resistant (IEC 60331-series) cables.
Helkama marine cables are approved by all
major classification societies.
As a specialized and independent company,
focusing on service, we have been able to
grow steadily by quickly responding to our
customers’ needs. Our short
delivery times, backed up by
extensive stocks, enable us to
deliver punctually and keep our
clients satisfied. This remains
our goal for the future, too.
Type Approval Certificates for factories in Finland and China
Please check updated approval situation on www.helkamabica.com
www.helkamabica.com
HELKAMA — a true specialist in marine cables
0,6/1kV CABLES
4
LKM-HF
Unarmoured power and
control cable 0,6/1kV
DESIGN:
STANDARDS:
IEC 60092-353, design
1. Conductor
- stranded copper conductor 1,0-10mm2 IEC 60228, class 2
- stranded copper conductor 16-300mm2 IEC 60228, class 5 (Flex)
- tinned stranded copper conductor on request
Flameretardant
2. Insulation
Fire- XLPE plastic
IEC 60092-360
resistant
5/2016
3. Bedding
- separator tape
4. Sheath
- polyolefine plastic, SHF1
IEC 60092-360
- on request, thermosetting polyolefine, SHF2
- standard colour black, other colours on request
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships
and offshore units.
Main characteristics
Rated voltage
AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification: see technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
5
Part number
Normal
G-type
28395
28396
27000
27002
27004
27006
27009
27011
27013
27015
27017
27019
27021
27023
27025
27027
27029
–
–
–
–
–
–
–
–
–
–
–
28397
25672
25689
25704
25706
25708
26072
26074
26076
26078
26080
26082
26085
26086
26088
26090
1x1,0
1x1,5
1x2,5
1x4
1x6
1x10
1x16 Flex
1x25 Flex
1x35 Flex
1x50 Flex
1x70 Flex
1x95 Flex
1x120 Flex
1x150 Flex
1x185 Flex
1x240 Flex
1x300 Flex
2x1,0
2x1,5
2x2,5
2x4
2x6
2x10
2x16 Flex
2x25 Flex
2x35 Flex
2x50 Flex
2x70 Flex
3x1,0
3x1,5
3x2,5
3x4
3x6
3x10
3x16 Flex
3x25 Flex
3x35 Flex
3x50 Flex
3x70 Flex
3x95 Flex
3x120 Flex
3x150 Flex
3x185 Flex
3x240 Flex
Nominal
outer
diameter
mm
5,0
5,5
5,5
6,5
7,0
8,0
9,0
11,5
12,0
14,0
16,5
18,0
20,0
23,0
25,0
28,0
31,5
7,5
8,5
9,5
10,5
12,0
14,0
16,5
20,5
22,5
26,5
30,5
8,0
9,0
10,0
11,5
13,0
15,0
17,5
22,0
24,0
28,5
33,0
37,0
41,5
47,5
52,5
59,5
Approximate
weight kg/km
35
40
55
70
95
140
185
290
380
535
740
955
1205
1520
1845
2455
3030
65
80
115
155
240
360
495
760
1015
1410
1955
80
100
145
200
310
465
630
970
1310
1840
2575
3320
4220
5335
6545
8695
Current
Rating A
at +45°C
18
23
30
40
52
72
94
123
153
196
240
284
331
381
429
507
582
15
20
26
34
44
61
80
105
130
167
204
13
16
21
28
36
50
66
86
107
137
168
199
232
267
300
355
Min. bending
radius fixed
installation
mm
20
25
25
30
30
35
40
50
50
60
70
75
85
95
155
170
190
30
35
40
45
50
60
70
85
95
160
185
35
40
45
50
55
65
75
90
100
175
200
225
250
285
320
360
G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Table continues on next page
5/2016
25580
25636
25638
25640
25642
25644
25647
25649
25651
25653
25655
25657
25659
25661
25663
25665
26047
25581
25670
25686
25702
25701
25717
26054
26055
26056
26057
26058
25582
25671
25688
25703
25705
25707
26071
26073
26075
26077
26079
26081
26083
26084
26087
26089
Number of
conductors &
cross-section
n x mm2
0,6/1kV CABLES
LKM-HF 0,6/1kV
5/2016
0,6/1kV CABLES
6
LKM-HF 0,6/1kV
Part number
Normal
G-type
25583
25673
25690
25725
25727
25729
26101
26103
26105
26107
26109
26111
26113
26115
26117
25584
25676
25692
25864
25866
25868
26131
26133
26135
26137
26139
26145
25585
25586
25587
25588
25589
25590
25592
25593
25597
25595
28398
25674
25691
25726
25728
25730
26102
26104
26106
26108
26110
26112
26114
26116
26118
28399
25677
25693
25865
25867
25869
26132
26134
26136
26138
26140
26146
28400
28401
28402
28403
28404
28405
28407
28408
28409
28411
Number of
conductors &
cross-section
n x mm2
4x1,0
4x1,5
4x2,5
4x4
4x6
4x10
4x16 Flex
4x25 Flex
4x35 Flex
4x50 Flex
4x70 Flex
4x95 Flex
4x120 Flex
4x150 Flex
4x185 Flex
5x1,0
5x1,5
5x2,5
5x4
5x6
5x10
5x16 Flex
5x25 Flex
5x35 Flex
5x50 Flex
5x70 Flex
5x95 Flex
7x1,0
10x1,0
12x1,0
14x1,0
16x1,0
19x1,0
24x1,0
27x1,0
30x1,0
37x1,0
Nominal
outer
diameter
mm
8,5
10,0
11,0
12,5
14,0
16,5
19,5
25,0
27,0
32,0
37,0
41,5
46,5
53,0
59,0
9,5
11,0
12,0
13,5
15,5
18,5
21,5
27,5
30,0
35,0
41,0
46,0
10,5
13,5
13,5
14,5
15,5
16,0
19,0
19,5
20,0
22,0
Approximate
weight kg/km
95
135
180
260
385
585
805
1255
1675
2365
3300
4305
5430
6895
8450
125
160
215
315
470
715
975
1545
2075
2920
4115
5360
155
220
250
280
325
365
465
510
555
680
Current
Rating A
at +45°C
13
16
21
28
36
50
66
86
107
137
168
199
232
267
300
10
13
17
23
30
42
55
71
89
114
139
165
9
8
8
7
7
7
6
6
5
5
Min. bending
radius fixed
installation
mm
35
40
45
55
60
70
80
100
165
195
225
250
280
320
355
40
45
50
55
65
75
90
165
180
215
250
275
45
55
55
60
65
65
80
80
85
90
G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Table continues on next page
7
Part number
Normal
G-type
Number of
conductors &
cross-section
n x mm2
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
25679
25668
25681
25992
25990
25683
25876
25685
25687
7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
37x1,5
11,5
15,0
15,5
16,5
17,0
18,5
22,0
22,0
25,0
200
290
335
380
430
495
635
700
920
12
11
10
10
9
9
8
8
7
50
60
65
70
70
75
90
90
100
25694
25993
25696
25995
25997
25873
25877
26141
26143
25695
25994
25874
25996
25998
25872
25878
26142
26144
7x2,5
10x2,5
12x2,5
14x2,5
16x2,5
19x2,5
24x2,5
27x2,5
37x2,5
13,5
17,0
17,5
18,5
19,5
20,5
24,5
25,0
28,5
285
410
465
535
605
690
900
990
1310
16
14
13
13
12
11
10
10
9
55
70
70
75
80
85
100
155
175
Other sizes on request.
G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
25678
25667
25680
25991
25989
25682
25875
25684
25675
0,6/1kV CABLES
LKM-HF 0,6/1kV
0,6/1kV CABLES
8
LKMM-HF
Unarmoured power cable
with extruded filler 0,6/1kV
DESIGN:
STANDARDS:
IEC 60092-353, design
1. Conductor
- stranded copper conductor 1,5–10mm2 IEC 60228, class 2
- stranded copper conductor 16–150mm2 IEC 60228, class 5
- tinned stranded copper conductor on request
5/2016
2. Insulation
- XLPE plastic
IEC 60092-360
3. Bedding
- extruded filler
4. Sheath
- polyolefine plastic, SHF1
IEC 60092-360
- on request, thermosetting polyolefine, SHF2
- standard colour black, other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships
and offshore units.
Main characteristics
Rated voltage
AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification: see technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
9
–
–
–
–
–
–
–
–
–
–
27566
27570
27574
27578
27582
27587
27591
27595
27599
27603
27607
27611
27615
27619
27623
27630
27634
27638
27642
27646
27651
27655
27659
27663
27667
27694
27698
27702
27706
27710
27715
27719
2x1,5
2x2,5
2x4
2x6
2x10
2x16 Flex
2x25 Flex
2x35 Flex
2x50 Flex
2x70 Flex
3x1,5
3x2,5
3x4
3x6
3x10
3x16 Flex
3x25 Flex
3x35 Flex
3x50 Flex
3x70 Flex
3x95 Flex
3x120 Flex
3x150 Flex
3x185 Flex
3x240 Flex
4x1,5
4x2,5
4x4
4x6
4x10
4x16 Flex
4x25 Flex
4x35 Flex
4x50 Flex
4x70 Flex
5x1,5
5x2,5
5x4
5x6
5x10
5x16 Flex
5x25 Flex
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
9,0
10,0
11,0
12,5
14,5
18,5
23,0
25,0
28,5
33,0
9,5
10,5
12,0
13,5
15,5
20,0
24,5
26,5
30,5
36,0
39,5
44,0
50,5
55,5
63,0
10,5
11,5
13,0
14,5
17,5
21,5
27,0
29,0
34,0
39,5
11,5
12,5
14,5
16,5
19,0
24,0
29,5
125
170
225
295
440
630
970
1305
1780
2435
140
190
260
360
530
770
1170
1570
2155
3020
3845
4840
6165
7510
9945
175
225
320
430
650
935
1440
1925
2660
3715
200
265
360
515
770
1150
1745
20
26
34
44
61
80
105
130
167
204
16
21
28
36
50
66
86
107
137
168
199
232
267
300
355
16
21
28
36
50
66
86
107
137
168
13
17
23
30
42
55
71
35
40
45
50
60
75
90
100
170
200
35
45
45
55
60
80
100
160
185
215
235
265
305
335
380
40
45
50
60
70
85
160
175
205
235
45
50
55
65
75
95
175
Other sizes on request.
G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
27532
27534
27536
27538
27540
27543
27545
27547
27549
27551
27564
27568
27572
27576
27580
27585
27589
27593
27597
27601
27605
27609
27613
27617
27621
27628
27632
27636
27640
27644
27649
27653
27657
27661
27665
27692
27696
27700
27704
27708
27713
27717
Nominal
outer
diameter
mm
5/2009
Part number
Normal
G-type
Number of
conductors &
cross-section
n x mm2
0,6/1kV CABLES
LKMM-HF 0,6/1kV
0,6/1kV CABLES
10
LKSM-HF
Armoured power and
control cable 0,6/1kV
5/2016
DESIGN:
STANDARDS:
IEC 60092-353, design
1. Conductor
- stranded copper conductor 1,0-10mm2 IEC 60228, class 2
- stranded copper conductor 16-300mm2 IEC 60228, class 5 (Flex)
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-360
3. Bedding
- filler tape
4. Armour
- copper wire braid, coverage > 90%
IEC 60092-350
- tinned copper wire braid on request
5. Sheath
- polyolefine plastic, SHF1
IEC 60092-360
- on request, thermosetting polyolefine, SHF2
- standard colour black, other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships
and offshore units.
Main characteristics
Rated voltage
AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification: see technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
11
Part number
Normal
G-type
Number of
conductors &
cross-section
n x mm2
Crosssection of
armour
mm2
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
28425
28426
27050
27052
27054
27056
27058
27060
27062
27064
27066
27068
27070
27072
27074
27076
27078
1x1,0
1x1,5
1x2,5
1x4
1x6
1x10
1x16 Flex
1x25 Flex
1x35 Flex
1x50 Flex
1x70 Flex
1x95 Flex
1x120 Flex
1x150 Flex
1x185 Flex
1x240 Flex
1x300 Flex
3,0
3,0
2,5
3,1
3,1
3,6
4,1
4,9
5,5
8,7
10,0
11,5
12,3
13,7
15,2
18,2
18,7
6,0
6,5
7,0
7,5
8,0
9,5
10,5
13,0
14,0
16,0
18,5
20,0
22,5
25,0
27,0
30,5
34,0
69
77
84
108
132
192
240
360
455
640
865
1095
1365
1690
2030
2670
3270
18
23
30
40
52
72
94
123
153
196
240
284
331
381
429
507
582
40
40
45
45
50
60
65
80
85
100
115
125
135
155
165
185
205
25956
25770
25785
25801
25803
25805
26254
26255
26256
26257
26258
26259
–
–
–
–
–
–
–
–
–
–
–
–
2x1,0
2x1,5
2x2,5
2x4
2x6
2x10
2x16 Flex
2x25 Flex
2x35 Flex
2x50 Flex
2x70 Flex
2x95 Flex
3,6
3,8
4,3
5,2
5,4
8,7
10,0
12,3
14,0
16,3
18,7
21,2
9,0
9,5
10,5
12,0
13,0
15,5
18,0
23,0
24,5
28,5
33,0
36,5
112
131
160
214
320
481
630
965
1210
1635
2225
2805
15
20
26
34
44
61
80
105
130
167
204
241
55
60
65
75
80
95
110
140
150
175
200
220
25957
25772
25786
25802
25804
25806
26271
26273
26275
26277
26279
26281
26283
26285
26287
26295
–
25773
25787
25880
25882
25884
26272
26274
26276
26278
26280
26282
26284
26286
26288
26296
3x1,0
3x1,5
3x2,5
3x4
3x6
3x10
3x16 Flex
3x25 Flex
3x35 Flex
3x50 Flex
3x70 Flex
3x95 Flex
3x120 Flex
3x150 Flex
3x185 Flex
3x240 Flex
3,7
4,1
5,2
5,3
5,8
9,3
10,7
13,2
15,0
17,5
20,2
22,8
35,1
39,3
43,4
50,7
9,5
10,0
11,0
12,5
14,0
16,5
19,0
24,5
26,0
30,5
35,5
39,0
44,0
50,0
55,0
62,0
129
155
200
264
376
574
755
1155
1485
2050
2790
3555
4570
5720
6955
9150
13
16
21
28
36
50
66
86
107
137
168
199
232
267
300
355
60
65
70
80
85
100
115
150
160
185
215
235
265
305
335
375
G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Table continues on next page
5/2016
25955
25736
25738
25740
25742
25744
26237
26238
26239
26240
26241
26242
26243
26244
26245
26246
26247
0,6/1kV CABLES
LKSM-HF 0,6/1kV
5/2016
0,6/1kV CABLES
12
LKSM-HF 0,6/1kV
Part number
Normal
G-type
Number of
conductors &
cross-section
n x mm2
Crosssection of
armour
mm2
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
25958
25774
25788
25830
25832
25834
26301
26303
26305
26307
26309
26311
26313
26315
26317
–
25775
25789
25831
25833
25835
26302
26304
26306
26308
26310
26312
26314
26316
26318
4x1,0
4x1,5
4x2,5
4x4
4x6
4x10
4x16 Flex
4x25 Flex
4x35 Flex
4x50 Flex
4x70 Flex
4x95 Flex
4x120 Flex
4x150 Flex
4x185 Flex
4,1
4,5
5,3
5,7
8,8
10,3
11,9
14,8
16,7
19,5
22,6
35,0
39,3
44,0
48,9
10,0
11,0
12,5
13,5
15,5
18,0
21,5
27,0
29,0
34,0
39,0
44,0
49,0
55,5
61,5
151
183
241
320
481
699
950
1440
1865
2580
3540
4665
5830
7330
8920
13
16
21
28
36
50
66
86
107
137
168
199
232
267
300
65
70
75
85
95
110
130
165
175
205
235
265
295
335
370
25959
25776
25790
26011
26013
26015
26331
26333
26335
26325
26327
26329
–
25777
25791
26012
26014
26016
26332
26334
26336
26326
26328
26330
5x1,0
5x1,5
5x2,5
5x4
5x6
5x10
5x16 Flex
5x25 Flex
5x35 Flex
5x50 Flex
5x70 Flex
5x95 Flex
4,5
5,0
5,6
8,6
9,7
11,5
13,2
16,3
18,6
22,4
34,4
39,3
10,5
12,0
13,5
15,0
17,0
20,0
23,0
29,5
32,0
37,0
43,5
48,5
175
221
284
413
571
839
1070
1640
2265
3120
4415
5695
10
13
17
23
30
42
55
71
89
114
139
165
65
75
80
95
105
120
140
180
195
225
265
295
25960
25961
25962
25963
25964
25965
25977
25978
25979
25981
–
–
–
–
–
–
–
–
–
–
7x1,0
10x1,0
12x1,0
14x1,0
16x1,0
19x1,0
24x1,0
27x1,0
30x1,0
37x1,0
4,9
8,7
9,0
9,4
10,0
10,6
12,5
12,8
13,3
14,4
11,5
15,0
15,0
16,0
17,0
17,5
20,5
21,0
21,5
23,5
214
319
350
387
435
484
611
658
710
840
9
8
8
7
7
7
6
6
5
5
75
90
95
100
105
110
125
130
135
145
G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G16
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Table continues on next page
13
Part number
Normal
G-type
Number of
conductors &
cross-section
n x mm2
Crosssection of
armour
mm2
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
25779
26026
25846
26028
26029
25781
25829
25847
–
25848
7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
30x1,5
37x1,5
5,4
9,6
10,0
10,5
11,1
11,7
13,9
14,1
14,7
16,0
13,0
16,5
17,0
18,0
19,0
19,5
23,5
24,0
24,5
26,5
266
396
446
496
549
615
789
854
924
1097
12
11
10
10
9
9
8
8
7
7
80
100
105
110
115
120
140
145
150
160
25792
25794
26033
26035
26037
25796
25798
25768
26040
25849
25793
25795
26034
26036
26038
25797
25799
25769
–
25850
7x2,5
12x2,5
10x2,5
14x2,5
16x2,5
19x2,5
24x2,5
27x2,5
30x2,5
37x2,5
8,5
10,8
11,5
11,8
12,5
13,2
15,7
16,1
16,7
18,1
15,0
18,5
19,0
20,5
21,5
22,5
26,0
27,0
27,5
30,0
378
525
588
676
752
846
1070
1165
1265
1524
16
14
13
13
12
11
10
10
10
9
90
115
115
125
130
135
160
165
170
185
Other sizes on request.
G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G16
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
25778
26025
25780
26027
26030
25782
25828
25783
26039
25784
0,6/1kV CABLES
LKSM-HF 0,6/1kV
0,6/1kV CABLES
14
LKMSM-HF
5/2016
DESIGN:
Armoured power cable
with extruded filler 0,6/1kV
STANDARDS:
IEC 60092-353, design
1. Conductor
- stranded copper conductor 1,5–10mm2 IEC 60228, class 2
- stranded copper conductor 16–150mm2 IEC 60228, class 5
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-360
3. Bedding
- extruded filler
4. Armour
- copper wire braid, coverage > 90%
IEC 60092-350
- tinned copper wire braid and galvanized steel wire braid
on request
5. Sheath
- polyolefine plastic, SHF1
IEC 60092-360
- on request, thermosetting polyolefine, SHF2
- standard colour black, other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships
and offshore units.
Main characteristics
Rated voltage
AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification: see technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
15
Part number
Normal
G-type
–
–
–
–
–
–
–
–
–
27266
27270
27274
27278
27282
27287
27291
27295
27299
27303
27307
27311
27315
27330
27334
27338
27342
27346
27351
27355
27359
27363
27367
27371
27375
27394
27398
27402
27406
27410
27415
27419
2x1,5
2x2,5
2x4
2x6
2x10
2x16 Flex
2x25 Flex
2x35 Flex
2x50 Flex
3x1,5
3x2,5
3x4
3x6
3x10
3x16 Flex
3x25 Flex
3x35 Flex
3x50 Flex
3x70 Flex
3x95 Flex
3x120 Flex
3x150 Flex
4x1,5
4x2,5
4x4
4x6
4x10
4x16 Flex
4x25 Flex
4x35 Flex
4x50 Flex
4x70 Flex
4x95 Flex
4x120 Flex
5x1,5
5x2,5
5x4
5x6
5x10
5x16 Flex
5x25 Flex
Crosssection of
armour
mm2
4,9
5,4
6,0
9,2
10,7
12,4
15,4
16,7
19,4
5,3
5,7
8,7
9,7
11,5
13,2
16,5
18,3
20,7
24,5
38,7
41,7
50,1
5,6
6,3
9,5
10,6
12,6
14,8
18,4
19,7
23,0
37,4
41,4
46,7
6,1
9,3
10,4
11,6
13,8
16,0
20,1
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
11,5
12,5
14,0
15,5
17,5
20,0
24,5
26,0
30,0
12,0
13,5
15,0
16,0
18,5
21,0
26,0
28,0
32,0
37,5
42,0
46,0
52,5
13,0
14,5
16,0
17,5
20,0
23,5
28,5
31,0
35,5
42,0
46,0
51,5
14,0
15,5
17,0
19,0
22,0
25,5
31,0
195
230
290
420
575
740
1085
1365
1825
220
275
365
490
685
885
1320
1685
2275
3135
4075
5015
6380
260
320
430
585
825
1090
1610
2075
2800
3985
5020
6320
295
390
510
685
980
1305
1920
20
26
34
44
61
80
105
130
167
16
21
28
36
50
66
86
107
137
168
199
232
267
16
21
28
36
50
66
86
107
137
168
199
232
13
17
23
30
42
55
71
70
75
85
90
105
120
145
155
180
75
80
90
95
110
125
155
165
195
225
250
275
315
80
85
95
105
120
140
170
185
210
250
275
310
85
95
105
115
130
150
185
Other sizes on request.
G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
27232
27234
27236
27238
27240
27243
27245
27247
27249
27264
27268
27272
27276
27280
27285
27289
27293
27297
27301
27305
27309
27313
27328
27332
27336
27340
27344
27349
27353
27357
27361
27365
27369
27373
27392
27396
27400
27404
27408
27413
27417
Number of
conductors &
cross-section
n x mm2
0,6/1kV CABLES
LKMSM-HF 0,6/1kV
0,6/1kV CABLES
16
LKAM-HF
Screened power and control cable
0,6/1kV
DESIGN:
STANDARDS:
IEC 60092-353, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
5/2016
2. Insulation
- XLPE plastic
IEC 60092-360
3. Screen
- drain wire of tinned copper 1,0mm2 (in all sizes)
- aluminium polyester tape,
IEC 60092-350
coverage 100%
4. Sheath
- polyolefine plastic, SHF1
IEC 60092-360
- on request, thermosetting polyolefine, SHF2
- standard colour black, other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships
and offshore units, especially when lightweight cables are needed.
Main characteristics
Rated voltage
AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification: see technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
17
Part number
Normal
G-type
–
27107
27111
27115
27119
27141
27123
27145
27149
27127
27131
27135
27156
27137
–
27109
27113
27117
27121
27143
27125
27147
27151
27129
27133
27139
27158
27153
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
2x1,5
3x1,5
4x1,5
5x1,5
7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
32x1,5
37x1,5
2x2,5
3x2,5
4x2,5
5x2,5
7x2,5
10x2,5
12x2,5
14x2,5
16x2,5
19x2,5
24x2,5
27x2,5
32x2,5
37x2,5
9,0
9,5
10,0
11,0
12,0
15,5
16,0
16,5
17,5
18,5
22,0
22,5
23,5
25,0
9,5
10,5
11,0
12,5
13,5
17,5
18,0
18,5
19,5
21,0
25,0
25,5
26,5
28,5
100
125
145
175
220
310
350
395
450
510
650
715
825
935
125
160
195
240
300
435
495
560
630
740
935
1025
1195
1355
20
16
16
13
12
11
10
10
9
9
8
8
7
7
26
21
21
17
16
14
13
13
12
11
10
10
9
9
55
55
60
65
70
90
95
100
105
110
130
135
140
150
60
60
65
75
80
105
105
110
120
125
150
150
160
170
Other sizes on request.
G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
27102
27106
27110
27114
27118
27140
27122
27144
27148
27126
27130
27134
27155
27136
27104
27108
27112
27116
27120
27142
27124
27146
27150
27128
27132
27138
27157
27152
Number of
conductors &
cross-section
n x mm2
0,6/1kV CABLES
LKAM-HF 0,6/1kV
0,6/1kV CABLES
18
LKEM-HF
DESIGN:
5/2016
1. Conductor
- stranded flexible
copper conductor
Switchboard wire
0,6/1kV
STANDARDS:
IEC 60092-353, design
IEC 60228,
class 5
2. Insulation
- HF90 plastic
IEC 60092-360
- standard colour black, other colours on request
- on request, oil resistant thermosetting polyolefine, SHF2
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed wiring in switchboards, control panels and other enclosures.
Main characteristics
Rated voltage
AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
-test for single insulated wire and cable
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
19
Part number
25117*
25120
25121
25122
25124
25125
25126
25128
25130
25132
25134
25136
25138
25165
25166
25279
25281
25283
25285
* Rated voltage 300/500V
Number of
conductors &
cross-section
n x mm2
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
1x0,5
1x0,75
1x1,0
1x1,5
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
2,3
2,7
2,8
3,1
3,6
4,1
4,7
5,7
6,7
8,6
9,7
11,9
13,7
16,2
18,2
20,8
23,3
26,8
28,9
10
14
17
21
32
45
63
103
153
241
330
472
665
879
1116
1411
1736
2336
2876
11
14
17
22
30
39
50
71
94
123
153
196
240
284
331
381
429
507
582
10
15
15
15
15
20
20
25
30
35
40
50
55
65
75
85
95
110
120
0,6/1kV CABLES
LKEM-HF 0,6/1kV
Other sizes on request.
5/2016
Available in colours:
blue, dark blue, black, brown, red, yellow, green, yellow/green, grey, orange, violet and white
Other colours on request
Delivery lengths:
0,5 mm2, 0,75 mm2, 1 mm2, 1,5 mm2 and 2,5 mm2 available in 200 m boxes or 500 m drums
4 mm2 available in 100 m boxes or 500 m drums
Part number for oil resistant SHF2 cable:
6 mm2 available in 100 m coils or 500 m drums
4 + code from above table © 4xxxxx
EMC CABLES
20
LKSM-EMC
Armoured power and control cable
with improved EMC screening 0,6/1kV
5/2016
DESIGN:
STANDARDS:
IEC 60092-353, design
1. Conductor
2
-stranded copper conductor 1,0-10mm 2 IEC 60228, class 2
-stranded copper conductor 16-300mm IEC 60228, class 5
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-360
3. Bedding
- filler tape
4. Screen
- copper tape, coverage 100%
5. Armour
- copper wire braid, coverage > 90%
IEC 60092-350
- tinned copper wire braid on request
6. Sheath
- polyolefine plastic, SHF1
IEC 60092-360
- on request, thermosetting polyolefine, SHF2
- standard colour black, other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships
and offshore units. Design to meet requirements for improved EMC
screening properties.
Main characteristics
Rated voltage
AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Transfer impedance
IEC 61196-1
(typical value 26dB over 1mΩ/m
at 100MHz [20mΩ/m])
For details see general information section
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification:
See technical information section.
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
21
Part number
Normal
G-type
Crosssection of
armour
mm2
Diameter
of screen
mm
Nominal
outer
diameter
mm
Approximate
weight
kg/km
Current
Rating A
at +45°C
3,0
3,0
3,0
3,1
3,1
3,3
4,2
5,3
5,6
8,8
10,0
11,2
12,4
13,8
15,3
17,1
18,8
3,3
3,6
4,2
4,6
5,3
8,5
10,1
12,4
14,1
16,4
18,8
21,3
4,0
4,0
4,5
5,0
6,0
7,0
8,5
10,5
11,5
14,0
16,0
18,5
20,0
23,0
25,5
29,0
31,0
6,5
7,0
8,0
9,0
10,5
12,5
15,5
19,5
21,5
26,0
29,5
34,5
6,0
6,5
7,0
7,5
8,0
9,5
11,0
13,5
14,5
17,0
19,0
21,5
24,0
26,5
29,5
33,0
35,5
9,5
10,0
11,0
12,0
13,0
16,0
18,5
23,0
25,5
30,0
34,0
39,0
80
90
100
120
145
210
280
410
510
700
935
1180
1460
1800
2160
2785
3410
130
145
180
230
340
535
715
1045
1320
1785
2385
3100
18
23
30
40
52
72
94
123
153
196
240
284
331
381
429
507
582
15
20
26
34
44
61
80
105
130
167
204
241
1x1,0
1x1,5
1x2,5
1x4
1x6
1x10
1x16 Flex
1x25 Flex
1x35 Flex
1x50 Flex
1x70 Flex
1x95 Flex
1x120 Flex
1x150 Flex
1x185 Flex
1x240 Flex
1x300 Flex
2x1,0
2x1,5
2x2,5
2x4
2x6
2x10
2x16 Flex
2x25 Flex
2x35 Flex
2x50 Flex
2x70 Flex
2x95 Flex
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Min. bending
radius fixed
installation
mm
35
40
40
45
50
55
65
80
85
100
115
130
145
160
175
195
215
55
60
65
70
80
95
110
140
155
180
205
235
Table continues on next page
5/2016
26904
27513
27514
27515
27516
27517
27518
27519
27520
27521
27522
27523
27524
27525
27526
27527
27528
26905
27480
27481
27482
27483
27484
27485
27486
27487
27529
27530
27531
Number of
conductors &
cross-section
n x mm2
EMC CABLES
LKSM-EMC 0,6/1kV
EMC CABLES
22
LKSM-EMC 0,6/1kV
5/2016
Part number
Normal
G-type
26906
26861
26863
26865
26867
26869
26872
26874
26876
26878
26880
26882
26884
26886
26907
26942
26944
26946
26948
26950
26952
26954
26956
26958
26960
26962
26964
26966
26908
27488
27489
27490
27491
27492
27493
27494
26988
26862
26864
26866
26868
26870
26851
26852
26853
26854
26855
26856
26857
26858
26989
26943
26945
26947
26949
26951
26953
26955
26957
26959
26961
26963
26965
26967
26990
27838
27839
27940
27941
27942
27943
27944
Number of
conductors &
cross-section
n x mm2
3x1,0
3x1,5
3x2,5
3x4
3x6
3x10
3x16 Flex
3x25 Flex
3x35 Flex
3x50 Flex
3x70 Flex
3x95 Flex
3x120 Flex
3x150 Flex
4x1,0
4x1,5
4x2,5
4x4
4x6
4x10
4x16 Flex
4x25 Flex
4x35 Flex
4x50 Flex
4x70 Flex
4x95 Flex
4x120 Flex
4x150 Flex
5x1,0
5x1,5
5x2,5
5x4
5x6
5x10
5x16 Flex
5x25 Flex
Crosssection of
armour
mm2
3,6
3,9
4,3
5,3
5,6
8,9
10,9
13,3
15,2
17,7
20,3
22,9
35,2
39,4
3,9
4,3
4,8
5,5
8,5
10,0
12,0
14,8
16,8
19,6
22,6
35,2
39,4
43,7
4,3
5,2
5,3
8,5
9,4
11,0
13,3
16,4
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Diameter
of screen
mm
Nominal
outer
diameter
mm
Approximate
weight
kg/km
Current
Rating A
at +45°C
7,0
7,5
8,5
10,0
11,0
13,5
16,5
21,0
23,0
27,5
32,0
37,0
41,5
47,5
8,0
8,5
9,5
11,0
12,5
15,0
18,0
23,0
25,5
31,0
35,5
42,0
46,5
52,5
8,5
9,5
10,5
12,5
14,0
16,5
20,0
25,5
10,0
10,5
11,5
12,5
14,0
16,5
19,5
24,5
27,0
32,0
36,5
42,0
47,0
53,0
10,5
11,0
12,5
13,5
15,5
18,5
22,0
27,0
30,0
35,5
40,0
47,5
52,5
59,0
11,0
12,0
13,5
15,5
17,0
20,0
23,5
29,5
155
175
215
285
395
600
835
1235
1590
2200
2955
3825
4875
6060
175
200
260
340
505
755
1015
1505
1960
2715
3675
4910
6095
7605
200
245
300
430
595
900
1215
1815
13
16
21
28
36
50
66
86
107
137
168
199
232
267
13
16
21
28
36
50
66
86
107
137
168
199
232
267
10
13
17
23
30
42
55
71
Min. bending
radius fixed
installation
mm
60
60
70
75
85
100
120
145
160
195
220
250
285
320
65
65
75
80
95
110
130
160
180
215
240
285
315
355
65
75
80
90
100
120
140
175
Table continues on next page
23
Part number
Normal
G-type
26991
26992
26993
26994
26995
26996
26997
26998
26999
27840
27842
27844
27846
27848
27850
27852
27854
27856
27841
27843
27845
27847
27849
27851
27853
27855
27857
7x1,0
10x1,0
12x1,0
14x1,0
16x1,0
19x1,0
24x1,0
27x1,0
37x1,0
7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
37x1,5
7x2,5
10x2,5
12x2,5
14x2,5
16x2,5
19x2,5
24x2,5
27x2,5
37x2,5
CrossDiameter
section of o f screen
armour
mm
mm2
4,7
9,5
8,5
12,5
8,6
13,0
9,1
13,5
9,7
14,5
10,2
15,0
12,2
18,0
12,5
18,5
14,0
20,5
5,3
10,0
9,2
13,5
9,6
14,0
10,2
15,0
10,8
15,5
11,5
16,5
13,5
19,5
13,9
20,0
15,7
22,5
5,9
11,5
10,5
15,5
10,9
16,0
11,5
17,0
12,2
18,0
12,9
19,0
15,4
22,5
15,8
23,0
17,8
25,5
Other sizes on request.
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Nominal
outer
diameter
mm
Approximate
weight
kg/km
12,5
15,5
16,0
16,5
17,5
18,5
21,5
22,0
24,5
13,0
16,5
17,0
18,0
19,0
20,0
23,0
24,0
26,5
14,5
18,5
19,0
20,0
21,5
22,5
26,0
27,0
30,0
240
355
385
420
460
550
700
745
935
285
420
465
520
570
675
855
930
1175
365
550
615
690
775
910
1145
1250
1610
Current
Rating A
at +45°C
9
8
8
7
7
7
6
6
5
12
20
16
10
13
23
8
16
7
30
26
13
21
17
11
26
21
30
Min. bending
radius fixed
installation
mm
75
95
95
100
105
110
130
130
145
80
100
100
110
115
120
140
145
160
85
110
115
120
130
135
155
160
180
5/2016
26909
26910
26911
26912
26913
26914
26915
26916
26917
27495
27497
27499
27501
27503
27505
27507
27509
27511
27496
27498
27500
27502
27504
27506
27508
27510
27512
Number of
conductors &
cross-section
n x mm2
EMC CABLES
LKSM-EMC 0,6/1kV
EMC CABLES
24
LKSM-EMC-FRHF
5/2016
DESIGN:
Fire-resistant armoured power
and control cable with improved
EMC screening 0,6/1kV
STANDARDS:
IEC 60092-353, design
1. Conductor
2
-stranded copper conductor 1,0-10mm 2 IEC 60228, class 2
Flame-stranded copper conductor 16-300mm IEC 60228, class 5
retardant
- tinned stranded copper conductor on request
Fire2. Insulation
resistant
- Mica tape
Halogen- XLPE plastic
IEC 60092-360
free
3. Bedding
Low smoke
- filler tape
emission
4. Screen
Oil resistant
- copper tape, coverage 100%
(only SHF2)
5. Armour
- copper wire braid, coverage > 90%
IEC 60092-350
- tinned copper wire braid on request
6. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-360
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request
Application: For fixed installation in most areas and on open deck in ships and offshore
units. If the cable is exposed to direct sun light protective covering or cable
with black outer shetah is recommended. Design to meet requirements
for improved EMC screening properties.
Main characteristics
Rated voltage
AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
Fire -resistant
Halogen-free
Smoke emission
Oil resistance (only SHF2)
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
IEC 60331-1 and IEC 60331-2
IEC 60754 series
IEC 61034 series
IEC 60811-404 conditions according to 60092-360/SHF2
Transfer impedance
IEC 61196-1
(typical value 26dB over 1mΩ/m
at 100MHz [20mΩ/m])
For details see general information section
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification:
See technical information section.
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
25
1x1,0
1x1,5
1x2,5
1x4
1x6
1x10
1x16 Flex
1x25 Flex
1x35 Flex
1x50 Flex
1x70 Flex
1x95 Flex
1x120 Flex
1x150 Flex
1x185 Flex
1x240 Flex
1x300 Flex
–
27872
27873
27874
27875
27876
27877
27878
27879
27880
27881
–
–
–
–
–
–
–
–
–
–
–
–
–
2x1,0
2x1,5
2x2,5
2x4
2x6
2x10
2x16 Flex
2x25 Flex
2x35 Flex
2x50 Flex
2x70 Flex
2x95 Flex
3,7
4,1
4,5
5,1
5,6
8,9
11,4
12,6
14,8
16,6
19,0
21,5
7,5
8,0
9,0
10,0
11,0
13,5
15,5
19,5
22,0
26,0
30,0
35,0
10,0
10,5
11,5
13,0
14,0
16,5
19,0
23,5
25,5
30,0
34,5
39,5
140
160
190
245
365
540
730
1070
1350
1815
2420
3150
15
20
26
34
44
61
80
105
130
167
204
241
60
65
70
75
85
100
115
140
155
180
205
240
–
27882
27883
27884
27885
27886
27887
27888
27889
27890
27891
27892
27893
27894
–
28444
28445
28446
28447
28448
28449
28450
28451
28452
28453
28454
28455
28456
3x1,0
3x1,5
3x2,5
3x4
3x6
3x10
3x16 Flex
3x25 Flex
3x35 Flex
3x50 Flex
3x70 Flex
3x95 Flex
3x120 Flex
3x150 Flex
4,0
4,3
4,8
5,5
11,3
9,6
11,5
14,7
15,8
18,5
22,2
32,5
36,1
40,2
8,0
8,5
9,5
10,5
12,5
14,5
17,5
21,5
24,0
28,5
32,5
38,5
42,5
48,0
10,5
11,0
12,5
13,5
15,5
17,5
20,5
25,5
28,0
33,0
37,5
43,5
48,0
54,0
170
190
240
305
485
630
890
1315
1675
2280
3055
4055
4980
6200
13
16
21
28
36
50
66
86
107
137
168
199
232
267
65
65
75
80
90
105
125
155
170
200
225
260
290
325
–
27897
27898
27899
27900
27905
27906
27907
27908
27909
27910
27912
27913
–
–
28459
28460
28461
28462
28463
28464
28465
28466
28467
28468
28469
28470
–
4x1,0
4x1,5
4x2,5
4x4
4x6
4x10
4x16 Flex
4x25 Flex
4x35 Flex
4x50 Flex
4x70 Flex
4x95 Flex
4x120 Flex
4x150 Flex
4,4
4,8
5,4
11,3
9,2
10,7
12,8
15,6
18,3
20,4
23,3
36,1
40,2
44,8
9,0
9,5
10,5
12,0
13,5
16,0
19,0
24,0
26,5
32,0
36,5
43,0
47,5
53,5
11,5
12,5
13,5
15,0
16,5
19,5
23,0
28,0
31,0
36,5
41,5
48,5
53,5
60,5
195
230
280
420
540
760
1085
1585
2080
2810
3820
5025
6245
7770
13
16
21
28
36
50
66
86
107
137
168
199
232
267
70
75
80
90
100
115
135
165
185
220
250
290
320
360
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Diameter
of screen
mm
Nominal
outer
diameter
mm
Approximate
weight
kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
4,5
4,5
5,0
5,5
6,0
7,0
8,5
10,5
11,5
13,5
15,5
18,0
20,0
22,5
25,5
28,5
31,0
6,5
7,0
7,5
8,0
8,5
10,0
11,0
13,0
14,0
17,0
18,5
21,5
23,5
26,5
29,0
32,5
35,5
90
100
110
130
155
215
285
410
515
705
935
1190
1465
1800
2165
2790
3420
18
23
30
40
52
72
94
123
153
196
240
284
331
381
429
507
582
40
40
45
45
50
60
65
80
85
100
110
130
140
160
175
195
210
Table continues on next page
5/2016
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Part number
Number of
conductors &
cross-section
n x mm2
EMC CABLES
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Crosssection of
armour
mm2
3,0
3,0
3,1
3,1
3,1
3,5
4,1
4,8
5,5
8,6
10,0
11,5
12,3
14,7
15,2
16,9
18,6
LKSM-EMC-FRHF
0,6/1kV
EMC CABLES
26
LKSM-EMC-FRHF
0,6/1kV
5/2016
Part number
Number of
conductors &
cross-section
n x mm2
Crosssection of
armour
mm2
4,9
5,3
6,0
11,3
11,4
11,9
14,1
17,2
Diameter
of screen
mm
Nominal
outer
diameter
mm
Approximate
weight
kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
9,5
10,5
11,5
13,5
15,0
18,0
21,0
26,5
12,5
13,0
14,5
16,5
18,0
21,5
25,0
30,5
230
265
330
485
650
930
1310
1915
10
13
17
23
30
42
55
71
75
80
85
100
110
130
150
185
–
27914
27915
27916
27917
27918
27919
27920
–
28471
28472
28473
28474
28475
28476
28477
5x1,0
5x1,5
5x2,5
5x4
5x6
5x10
5x16 Flex
5x25 Flex
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
7x1,0
10x1,0
12x1,0
14x1,0
16x1,0
19x1,0
24x1,0
27x1,0
30x1,0
37x1,0
5,4
9,6
10,0
10,5
11,1
11,8
13,9
14,4
14,9
16,2
10,5
14,0
14,5
15,5
16,5
17,0
20,5
21,0
21,5
23,5
13,5
17,0
18,0
18,5
19,5
20,5
24,0
24,5
25,5
27,5
270
400
445
495
540
630
815
870
935
1090
9
8
8
7
7
7
6
6
6
5
80
105
105
110
115
125
145
150
155
165
27921
27923
27925
27927
27929
27931
27933
27935
–
27937
28478
28480
28482
28484
28486
28488
28490
28492
–
28494
7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
30x1,5
37x1,5
5,9
10,5
10,9
11,5
12,2
12,9
15,3
15,8
16,4
17,8
11,5
15,0
15,5
16,5
17,5
18,5
22,0
22,5
23,5
25,5
14,5
18,5
19,0
20,0
21,0
22,0
26,0
26,5
27,5
30,0
315
475
525
585
665
780
975
1055
1135
1345
12
11
10
10
9
9
8
8
7
7
85
110
115
120
125
135
155
160
165
180
27922
27924
27926
27928
27930
27932
27934
27936
–
27938
28479
28481
28483
28485
28487
28489
28491
28493
–
28495
7x2,5
10x2,5
12x2,5
14x2,5
16x2,5
19x2,5
24x2,5
27x2,5
30x2,5
37x2,5
11,3
11,7
12,1
12,8
13,6
14,4
17,2
17,6
18,3
20,0
13,0
17,0
17,5
18,5
19,5
21,0
24,5
25,5
26,5
28,5
16,0
20,0
21,0
22,0
23,5
24,5
28,5
29,5
30,5
33,0
455
600
700
780
860
1020
1280
1410
1525
1790
16
14
13
12
12
11
10
10
10
9
95
120
125
135
140
150
170
180
185
200
Other sizes on request.
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
27
EMC CABLES
5/2016
EMC CABLES
28
RFE-EMC
Armoured pair instrumentation and
communication cable with improved
EMC screening 250V
5/2016
DESIGN:
STANDARDS:
IEC 60092-376, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-360
3. Twisted pair
- two insulated cores twisted together to form a pair
See next page for Quad
4. Bedding
- filler tape
5. Screen
- drain wire copper (in all sizes)
- copper tape 100%
6. Armour
- copper wire braid, coverage >94%
EC 60092-350
- tinned copper wire braid on request
- the armour serves as a collective screen
7. Sheath
- polyolefine plastic, SHF1
EC 60092-360
- on request, thermosetting polyolefine, SHF2
- standard colour grey, other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships and offshore
units. If the cable is exposed to direct sun light protective covering or cable
with black outer sheath is recommended. Design to meet requirements for
improved EMC screening properties.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant
Halogen-free
Smoke emission
Oil resistance (only SHF2)
Transfer impedance
150/250V (300V)
+ 90 °C
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
IEC 60754 series
IEC 61034 series
IEC 60811-404 conditions according to 60092-360/SHF2
IEC 61196-1
(typical value 26dB over 1mΩ/m
at 100MHz [20mΩ/m])
Electrical data:
Loop resistance of pair, max. / +20°C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20°C
0,5mm2 0,75mm2
80
52
55
50
0,6
0,6
≥1500
≥1500
1,5mm2
24,4
60
0,7
≥1500
Unit
ohm/km
nF/km
mH/km
Mohm/km
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification: See technical information section
Identification: Lot number, cable type, cable size, voltage, temperature, standards,
manufacturer's name, production month and meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
29
Part number
Number of
conductors &
cross-section
n x mm2
Nominal
outer
diameter
mm
Approximate
weight kg/km
Min. bending
radius fixed
installation
mm
1x2x0,5
1x3x0,5
1x4x0,5
2x2x0,5
3x2x0,5
4x2x0,5
7x2x0,5
8x2x0,5
10x2x0,5
12x2x0,5
14x2x0,5
16x2x0,5
19x2x0,5
24x2x0,5
27x2x0,5
30x2x0,5
32x2x0,5
37x2x0,5
8,5
8,5
9,0
11,0
11,5
12,0
14,0
15,0
16,5
17,0
18,0
19,0
20,5
22,5
23,5
24,5
25,5
27,0
95
135
145
150
170
195
260
280
360
400
435
480
540
655
710
760
810
895
50
50
55
65
70
75
85
90
100
105
110
115
125
135
140
145
150
160
21987
21988
21989
21990
21991
21992
21993
21994
21995
21996
21997
21998
21999
22000
22001
22002
22003
22004
1x2x0,75
1x3x0,75
1x4x0,75
2x2x0,75
3x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
16x2x0,75
19x2x0,75
24x2x0,75
27x2x0,75
30x2x0,75
32x2x0,75
37x2x0,75
9,0
9,5
10,0
12,5
13,0
14,0
16,0
17,5
19,5
20,0
21,5
23,0
24,5
26,5
28,0
29,5
30,0
32,5
110
150
165
185
210
245
330
400
475
520
580
655
740
885
975
1055
1105
1265
55
55
60
75
75
85
95
105
115
120
130
135
145
160
170
175
180
195
22375
22376
22377
22378
22379
22380
22381
22382
22383
22384
22385
22386
22387
22388
22389
22390
22391
22392
1x2x1,5
1x3x1,5
1x4x1,5
2x2x1,5
3x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
16x2x1,5
19x2x1,5
24x2x1,5
27x2x1,5
30x2x1,5
32x2x1,5
37x2x1,5
11,5
12,0
12,5
15,5
16,5
18,0
21,5
23,0
25,5
27,0
28,5
30,5
32,5
36,5
38,0
40,0
41,0
44,5
170
210
240
280
325
425
605
690
820
930
1045
1165
1330
1640
1800
1975
2075
2480
70
70
75
95
100
110
130
140
155
160
170
180
195
220
230
240
245
265
Other sizes on request.
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
21968
21969
21970
21971
21972
21973
21974
21975
21976
21977
21978
21979
21980
21981
21982
21983
21984
21985
EMC CABLES
RFE-EMC 250V
EMC CABLES
30
RFE-EMC(i)
5/2016
DESIGN:
Armoured and individually screened
instrumentation and communication cable
250V
STANDARDS:
IEC 60092-376, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-360
3. Twisted pair & individual screen
- two insulated cores twisted together to form a pair
- plastic coated aluminium tape and a tinned copper drain wire
4. Bedding
- filler tape
5. Screen
- drain wire copper (in all sizes)
- copper tape 100%
6. Armour
- copper wire braid, coverage >94%
IEC 60092-350
- tinned copper wire braid on request
7. Sheath
- polyolefine plastic, SHF1
EC 60092-360
- on request, thermosetting polyolefine, SHF2
- standard colour grey, other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships and offshore
units. If the cable is exposed to direct sun light protective covering or cable
with black outer sheath is recommended. Design to meet requirements for
improved EMC screening properties.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant
Halogen-free
Smoke emission
Oil resistance (only SHF2)
Transfer impedance
150/250V (300V)
+ 90 °C
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
IEC 60754 series
IEC 61034 series
IEC 60811-404 conditions according to 60092-360/SHF2
IEC 61196-1
(typical value 26dB over 1mΩ/m
at 100MHz [20mΩ/m])
Electrical data:
Loop resistance of pair, max. / +20°C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20°C
0,5mm2 0,75mm2
80
52
55
70
0,6
0,6
≥1500
≥1500
1,5mm2
24,4
90
0,7
≥1500
Unit
ohm/km
nF/km
mH/km
Mohm/km
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification: See technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
31
Part number
1x2x0,5
1x3x0,5
1x4x0,5
2x2x0,5
3x2x0,5
4x2x0,5
7x2x0,5
8x2x0,5
10x2x0,5
12x2x0,5
14x2x0,5
16x2x0,5
19x2x0,5
24x2x0,5
27x2x0,5
30x2x0,5
32x2x0,5
37x2x0,5
1x2x0,75
1x3x0,75
1x4x0,75
2x2x0,75
3x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
16x2x0,75
19x2x0,75
24x2x0,75
27x2x0,75
30x2x0,75
32x2x0,75
37x2x0,75
1x2x1,5
1x3x1,5
1x4x1,5
2x2x1,5
3x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
16x2x1,5
19x2x1,5
24x2x1,5
27x2x1,5
30x2x1,5
32x2x1,5
37x2x1,5
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Nominal
outer
diameter
mm
Approximate
weight kg/km
Min. bending
radius fixed
installation
mm
8,5
8,5
9,0
11,0
11,5
12,5
14,5
15,0
17,0
17,5
19,0
19,5
21,0
23,5
24,5
25,5
26,0
27,5
9,0
9,5
10,0
12,5
13,0
14,0
17,0
17,5
20,0
20,5
22,0
23,0
25,0
27,5
28,5
30,5
31,0
33,0
11,5
12,0
12,5
16,0
17,0
18,5
21,5
23,0
25,5
27,5
29,0
31,0
33,5
37,0
39,0
41,0
42,5
45,0
105
120
140
170
200
235
330
360
465
520
590
650
735
910
1000
1085
1140
1290
120
140
150
195
235
270
410
450
540
600
690
755
870
1045
1145
1270
1330
1490
180
205
240
295
390
465
670
760
910
1040
1185
1310
1530
1875
2060
2280
2505
2835
50
50
55
65
70
75
85
90
100
105
115
120
125
140
145
150
155
165
55
55
60
75
80
85
100
105
120
125
135
140
150
165
170
180
185
195
70
70
75
95
100
110
130
140
155
165
175
185
200
220
235
245
255
270
5/2016
21949
21950
21951
21952
21953
21954
21955
21956
21957
21958
21959
21960
21961
21962
21963
21964
21965
21966
21911
21912
21913
21914
21915
21916
21917
21918
21919
21920
21921
21922
21923
21924
21925
21926
21927
21928
21930
21931
21932
21933
21934
21935
21936
21937
21938
21939
21940
21941
21942
21943
21944
21945
21946
21947
Other sizes on request.
Number of
conductors &
cross-section
n x mm2
EMC CABLES
RFE-EMC(i) 250V
5/2016
EMC CABLES
32
RFE-EMC-FRHF
Fire-resistant armoured pair
instrumentation and communication cable
with improved EMC screening 250V
DESIGN:
STANDARDS: IEC 60092-376, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic
IEC 60092-360
Flame3. Twisted pair
retardant
- two insulated cores twisted together to form a pair
FireSee next page for Quad
resistant
4. Bedding
Halogen- filler tape
free
5. Screen
Low smoke
- drain wire copper (in all sizes)
emission
- copper tape 100%
Oil resistant
6. Armour
(only SHF2)
- the armour serves as a collective screen
- drain wire (in all sizes)
- copper wire braid, coverage > 94%
IEC 60092-350
- tinned copper wire braid on request
7. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-360
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request
Application: For fixed installation in most areas and on open deck in ships and offshore
units. If the cable is exposed to direct sun light protective covering or cable
with black outer sheath is recommended. Design to meet requirements for
improved EMC screening properties.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant
150/250V (300V)
+ 90 °C
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Fire-resistant
IEC 60331-1 or IEC 60331-2
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
0,75mm2 1,5mm2 Unit
Electrical data
52
24,4
ohm/km
Loop resistance of pair, max. / +20°C
45
55
nF/km
Pair capacitance, nom. / 800Hz
0,6
0,7
mH/km
Loop inductance, nom.
≥1500
≥1500
Mohm/km
Insulation resistance / +20°C
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
33
Part number
1x2x0,75
1x4x0,75
2x2x0,75
3x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
16x2x0,75
19x2x0,75
24x2x0,75
27x2x0,75
30x2x0,75
32x2x0,75
37x2x0,75
1x2x1,5
1x4x1,5
2x2x1,5
3x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
16x2x1,5
19x2x1,5
24x2x1,5
27x2x1,5
30x2x1,5
32x2x1,5
37x2x1,5
Other sizes on request.
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Nominal
outer
diameter
mm
Approximate
weight kg/km
Min. bending
radius fixed
installation
mm
11,0
12,5
15,0
15,5
16,5
19,5
20,5
23,0
24,0
25,0
25,5
27,5
31,0
32,5
34,0
35,0
37,0
13,0
14,0
18,0
19,0
20,5
24,0
25,5
28,0
29,0
31,0
33,0
35,5
39,5
42,5
44,5
45,5
49,0
145
195
240
270
310
460
510
615
675
745
820
920
1130
1230
1345
1410
1570
210
275
400
450
500
730
800
965
1080
1210
1370
1560
1910
2285
2465
2660
2920
65
75
90
90
100
115
125
140
145
150
155
165
185
195
205
210
220
80
85
110
115
125
145
150
170
175
185
200
215
235
255
265
275
295
5/2016
22915
22917
22918
22919
22920
22921
22922
22923
22924
22925
22926
22927
22928
22929
22930
22931
22932
22934
22936
22937
22938
22939
22940
22941
22942
22943
22944
22945
22946
22947
22948
22949
22950
22951
Number of
conductors &
cross-section
n x mm2
EMC CABLES
RFE-EMC-FRHF 250V
5/2016
EMC CABLES
34
RFE-EMC-FRHF(i)
Armoured and individually screened
instrumentation and communication cable
with improved EMC screening 250V
DESIGN:
STANDARDS: IEC 60092-376, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic
IEC 60092-360
Flame3. Twisted pair & individual screen
retardant
- two insulated cores twisted together to form a pair
Fire- plastic coated aluminium tape and a tinned copper drain wire
resistant
4. Bedding
Halogen- filler tape
free
4. Screen
Low smoke
- drain wire copper (in all sizes)
emission
- copper tape 100%
Oil resistant
(only SHF2)
5. Armour
- drain wire copper
- copper wire braid, coverage > 94%
IEC 60092-350
- tinned copper wire braid on request
6. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-360
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request
Application: For fixed installation in most areas and on open deck in ships and offshore
units. If the cable is exposed to direct sun light protective covering or cable
with black outer sheath is recommended. Design to meet requirements for
improved EMC screening properties.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant
Fire-resistant
Halogen-free
Smoke emission
Oil resistance (only SHF2)
150/250V (300V)
+ 90 °C
IEC 60332-1-2
IEC 60332-3-22
-test for single insulated wire and cable
-test for bunched wires and cables,
category A
IEC 60331-1 or IEC 60331-2
IEC 60754 series
IEC 61034 series
IEC 60811-404 conditions according to 60092-360/SHF2
Electrical data
Loop resistance of pair, max. / +20°C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20°C
0,75mm2 1,5mm2
52
24,4
55
75
0,6
0,7
≥1500
≥1500
Unit
ohm/km
nF/km
mH/km
Mohm/km
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
35
1x2x0,75
1x4x0,75
2x2x0,75
3x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
16x2x0,75
19x2x0,75
24x2x0,75
27x2x0,75
30x2x0,75
32x2x0,75
37x2x0,75
1x2x1,5
1x4x1,5
2x2x1,5
3x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
16x2x1,5
19x2x1,5
24x2x1,5
27x2x1,5
30x2x1,5
32x2x1,5
37x2x1,5
Other sizes on request.
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Approximate
weight kg/km
Min. bending
radius fixed
installation
mm
10,5
12,5
15,5
16,0
18,0
21,0
22,0
25,5
26,5
28,5
30,0
32,0
36,0
37,5
39,5
40,5
43,0
12,0
13,5
17,5
18,0
20,0
23,5
25,5
28,5
30,5
32,0
34,0
36,5
41,5
43,5
46,0
47,0
50,0
145
200
250
295
385
540
590
730
825
920
1030
1170
1445
1580
1710
1820
2035
190
260
385
425
515
755
850
1030
1190
1340
1500
1715
2300
2505
2750
2855
3230
65
75
90
95
105
125
135
150
160
170
180
195
215
225
235
245
260
70
80
105
110
120
140
150
170
180
195
205
220
250
260
275
280
300
5/2016
22858
22860
22861
22862
22863
22864
22865
22866
22867
22868
22869
22870
22871
22872
22873
22874
22875
22877
22879
22880
22881
22882
22883
22884
22885
22886
22887
22888
22889
22890
22891
22892
22893
22894
Nominal
outer
diameter
mm
EMC CABLES
Part number
Number of
conductors &
cross-section
n x mm2
RFE-EMC-FRHF(I) 250V
1,8/3kV CABLES
36
LKSM-VFD
Armoured power and control cable
with improved EMC screening 1,8/3kV
5/2016
DESIGN:
STANDARDS:
IEC 60092-353, design
1. Conductor
- stranded copper conductor
IEC 60228, class 5
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-360
3. Bedding
- filler tape
4. Screen
- copper tape, coverage 100%
5. Armour
- copper wire braid, coverage > 90%
IEC 60092-350
- tinned copper wire braid on request
6. Sheath
- polyolefine plastic, SHF1
IEC 60092-360
- on request, thermosetting polyolefine, SHF2
- standard colour black, other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships and offshore
units. Design to meet requirements for Variable Frequency Drivers (VFD).
Suitable for voltage peaks up to 3kV.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant
1,8/3kV (3,6kV)
Halogen-free
Smoke emission
+ 90 °C
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
IEC 60754 series
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Transfer impedance
IEC 61196-1
(typical value 26dB over 1mΩ/m
at 100MHz [20mΩ/m])
For details see general information section
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification:
See technical information section.
Cable with yellow/green protective earth (PE)
conductor on request
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
37
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x95+3x16
3x120+3x25
3x150+3x25
4,7
5,5
8,5
9,3
10,3
11,3
12,5
13,6
14,7
15,8
17,6
18,9
13,2
16,4
16,9
18,7
28,8
35,2
35,4
38,6
42,0
45,5
50,2
35,4
38,6
42,0
Other sizes on request.
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
NOTE!
1) = Protective earth (PE) rules are not fulfilled.
(PE rules, for cables over 16mm2 the PEconductor have to be half of main conductor
and min. 16mm2. This according to
IEC 60092-352, Electrical installations in
ships –Choice and installation of electrical
cables)
2 = Three additional protective earth (PE)
conductors. Protective earth (PE)
rules are fulfilled.
Approximate
weight
kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
12,5
14,0
16,0
17,0
19,0
20,5
23,5
25,5
27,5
29,5
33,0
35,0
23,5
26,5
29,5
32,5
37,0
41,0
46,5
50,5
55,0
60,0
67,0
46,5
50,5
55,0
280
355
495
625
795
995
1280
1525
1830
2165
2800
3365
880
1160
1525
1910
2580
3395
4295
5200
6255
7475
9620
4650
5755
6780
71
94
123
153
196
240
284
331
381
429
507
582
50
66
86
107
137
168
199
232
267
300
355
199
232
267
75
85
95
105
115
125
140
150
165
180
200
210
140
160
180
195
225
245
280
305
330
360
405
280
305
330
Note
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
2)
2)
2)
5/2016
26918
26920
26922
26924
26926
26928
26930
26932
26934
26936
26938
26940
26892
26871
26873
26875
26877
26879
26881
26883
26885
26887
26889
26893
26895
26897
Nominal
outer
diameter
mm
1,8/3kV CABLES
Part number
Number of
Crossconductors & section of
cross-section armour
n x mm2
mm2
LKSM-VFD 1,8/3kV
0,6/1kV CABLES
38
LKM-FRHF
DESIGN:
Fire-resistant unarmoured power
and control cable 0,6/1kV
STANDARDS:
IEC 60092-353, design
1. Conductor
- stranded copper conductor 1,0–10mm2
IEC 60228, class 2
- stranded copper conductor 16–300mm2 IEC 60228, class 5 (Flex)
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic
IEC 60092-360
5/2016
3. Bedding
- separator tape
4. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-360
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships and offshore
units. If the cable is exposed to direct sun light protective covering or cable
with black outer sheath is recommended.
Main characteristics
Rated voltage
AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Fire-resistant
IEC 60331-1 or IEC 60331-2
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification: see technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
39
Part number
Normal
G-type
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
28279
28163
28165
28167
28169
28171
29367
29369
29371
29373
29375
29377
29379
29381
29383
29385
1x1,0
1x1,5
1x2,5
1x4
1x6
1x10
1x16 Flex
1x25 Flex
1x35 Flex
1x50 Flex
1x70 Flex
1x95 Flex
1x120 Flex
1x150 Flex
1x185 Flex
1x240 Flex
1x300 Flex
2x1,0
2x1,5
2x2,5
2x4
2x6
2x10
2x16 Flex
2x25 Flex
2x35 Flex
2x50 Flex
2x70 Flex
2x95 Flex
3x1,0
3x1,5
3x2,5
3x4
3x6
3x10
3x16 Flex
3x25 Flex
3x35 Flex
3x50 Flex
3x70 Flex
3x95 Flex
3x120 Flex
3x150 Flex
3x185 Flex
3x240 Flex
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
5,5
5,5
6,0
6,5
7,5
8,5
9,5
11,5
12,5
14,5
16,5
18,5
20,5
23,5
25,5
28,5
32,0
8,5
9,0
10,5
11,5
12,5
15,0
17,5
21,5
23,5
27,5
31,5
35,5
8,5
9,5
11,0
12,0
13,5
16,0
18,5
23,0
25,0
29,5
34,0
38,0
42,5
48,5
53,5
60,5
40
45
60
80
105
150
200
305
400
555
765
985
1235
1555
1880
2495
3075
75
90
125
170
260
385
530
805
1070
1475
2030
2625
90
115
160
220
330
490
675
1030
1380
1915
2670
3425
4335
5450
6680
8840
18
23
30
40
52
72
94
123
153
196
240
284
331
381
429
507
582
15
20
26
34
44
61
80
105
130
167
204
241
13
16
21
28
36
50
66
86
107
137
168
199
232
267
300
355
30
35
35
40
45
50
40
50
55
60
70
75
85
95
155
175
195
50
55
60
70
75
90
70
90
95
165
190
215
50
60
65
75
80
95
75
95
155
180
205
230
255
290
325
365
G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Table continues on next page
5/2016
28275
28100
28102
28104
28106
28108
29326
29327
29328
29329
29330
29331
29332
29333
29334
29335
29336
28276
28132
28134
28136
28138
28140
29343
29344
29345
29346
29347
29348
28278
28162
28164
28166
28168
28170
29366
29368
29370
29372
29374
29376
29378
29380
29382
29384
Number of
conductors &
cross-section
n x mm2
0,6/1kV CABLES
LKM-FRHF 0,6/1kV
5/2016
0,6/1kV CABLES
40
LKM-FRHF 0,6/1kV
Part number
Normal
G-type
28280
28182
28184
28186
28188
28190
29400
29402
29404
29406
29408
29410
28282
28212
28214
28501
28503
28505
29434
29436
29438
29440
29442
28281
28183
28185
28187
28189
28191
29401
29403
29405
29407
29409
29411
28283
28213
28215
28502
28504
28506
29435
29437
29439
29441
29443
Number of
conductors &
cross-section
n x mm2
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
4x1,0
4x1,5
4x2,5
4x4
4x6
4x10
4x16 Flex
4x25 Flex
4x35 Flex
4x50 Flex
4x70 Flex
4x95 Flex
5x1,0
5x1,5
5x2,5
5x4
5x6
5x10
5x16 Flex
5x25 Flex
5x35 Flex
5x50 Flex
5x70 Flex
9,5
11,0
12,0
13,5
15,0
17,5
20,5
25,5
28,0
33,0
38,0
42,5
11,0
12,0
13,0
15,0
16,5
19,5
22,5
28,5
31,0
36,5
42,5
115
150
200
280
410
620
865
1330
1760
2465
3420
4435
145
180
240
345
505
755
1050
1630
2175
3040
4265
13
16
21
28
36
50
66
86
107
137
168
199
10
13
17
23
30
42
55
71
89
114
139
55
65
70
80
90
105
85
155
170
200
230
255
65
70
80
90
100
115
95
175
185
220
255
G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Table continues on next page
41
Part number
Normal
G-type
28285
28287
28289
28291
28293
28295
28297
28299
28301
28217
28241
28221
28245
28249
28225
28229
28233
28235
28219
28243
28223
28247
28251
28227
28231
28237
28239
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
12,0
15,0
15,5
16,5
17,5
18,5
21,5
22,0
25,0
13,0
16,5
17,5
18,5
19,5
20,5
24,5
25,0
28,0
14,5
18,5
19,5
20,5
21,5
23,0
27,5
28,0
31,5
180
260
295
330
380
435
550
600
805
230
330
380
430
485
565
725
795
1050
315
450
510
590
670
765
995
1095
1450
9
8
8
7
7
7
6
6
5
12
11
10
10
9
9
8
8
7
16
14
13
13
12
11
10
10
9
70
90
95
100
105
110
130
130
150
80
100
105
110
115
125
145
150
170
90
110
115
125
130
135
165
170
190
7x1,0
10x1,0
12x1,0
14x1,0
16x1,0
19x1,0
24x1,0
27x1,0
37x1,0
7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
37x1,5
7x2,5
10x2,5
12x2,5
14x2,5
16x2,5
19x2,5
24x2,5
27x2,5
37x2,5
Other sizes on request.
G-type is with yellow/green earth conductor and
marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
28284
28286
28288
28290
28292
28294
28296
28298
28300
28216
28240
28220
28244
28248
28224
28228
28232
28234
28218
28242
28222
28246
28250
28226
28230
28236
28238
Number of
conductors &
cross-section
n x mm2
0,6/1kV CABLES
LKM-FRHF 0,6/1kV
5/2016
0,6/1kV CABLES
42
LKMM-FRHF
Fire-resistant unarmoured
power cable with extruded filler
0,6/1kV
DESIGN:
STANDARDS:
IEC 60092-353, design
1. Conductor
- stranded copper conductor 1,5–10mm2 IEC 60228, class 2
- stranded copper conductor 16–150mm2 IEC 60228, class 5
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic
IEC 60092-360
3. Bedding
- extruded filler
4. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-360
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships
and offshore units.
Main characteristics
Rated voltage
AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Fire-resistant
IEC 60331-1 or IEC 60331-2
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification: see technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
43
Part number
Normal
G-type
–
–
–
–
–
–
–
–
–
–
29551
29553
29555
29557
29559
29561
29563
29565
29567
29569
29571
29573
29575
29577
29579
29585
29587
29589
29591
29593
29595
29597
29599
29601
29603
29619
29621
29623
29625
29627
29629
29631
2x1,5
2x2,5
2x4
2x6
2x10
2x16 Flex
2x25 Flex
2x35 Flex
2x50 Flex
2x70 Flex
3x1,5
3x2,5
3x4
3x6
3x10
3x16 Flex
3x25 Flex
3x35 Flex
3x50 Flex
3x70 Flex
3x95 Flex
3x120 Flex
3x150 Flex
3x185 Flex
3x240 Flex
4x1,5
4x2,5
4x4
4x6
4x10
4x16 Flex
4x25 Flex
4x35 Flex
4x50 Flex
4x70 Flex
5x1,5
5x2,5
5x4
5x6
5x10
5x16 Flex
5x25 Flex
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
12,0
13,0
13,5
15,5
17,0
20,0
24,5
26,0
30,5
35,5
12,0
13,0
15,0
15,5
18,0
20,5
26,0
28,5
32,5
38,5
43,5
48,0
54,5
61,0
70,0
13,0
14,0
15,5
17,0
20,5
23,5
28,5
30,5
37,0
42,5
14,0
16,0
17,5
18,5
21,5
25,5
30,5
165
195
250
315
440
570
840
1145
1555
2095
190
240
305
395
560
735
1095
1475
2015
2805
3630
4535
5720
7010
9220
230
285
370
490
700
940
1380
1860
2580
3545
270
335
450
585
850
1145
1710
23
30
40
52
72
94
123
153
196
240
23
30
40
52
72
94
123
153
196
240
284
331
381
429
507
23
30
40
52
72
94
123
153
196
240
23
30
40
52
72
94
123
70
75
85
90
105
120
145
160
185
210
75
80
90
95
110
125
155
170
195
230
265
290
330
370
420
80
85
95
105
120
140
170
185
220
250
85
95
105
115
130
150
185
Other sizes on request.
G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
29532
29533
29534
29535
29536
29537
29538
29539
29540
29541
29550
29552
29554
29556
29558
29560
29562
29564
29566
29568
29570
29572
29574
29576
29578
29584
29586
29588
29590
29592
29594
29596
29598
29600
29602
29618
29620
29622
29624
29626
29628
29630
Number of
conductors &
cross-section
n x mm2
0,6/1kV CABLES
LKMM-FRHF 0,6/1kV
0,6/1kV CABLES
44
LKSM-FRHF
5/2016
DESIGN:
Fire-resistant armoured power
and control cable 0,6/1kV
STANDARDS:
IEC 60092-353, design
1. Conductor
- stranded copper conductor 1,0–10mm2 IEC 60228, class 2
- stranded copper conductor 16–300mm2 IEC 60228, class 5 (Flex)
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic
EC 60092-360
3. Bedding
- separator tape
4. Armour
- copper wire braid, coverage > 90%
IEC 60092-350
- tinned copper wire braid on request
5. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-360
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships and offshore
units. If the cable is exposed to direct sun light protective covering or cable
with black outer sheath is recommended.
Main characteristics
Rated voltage
AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Fire-resistant
IEC 60331-1 or IEC 60331-2
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification: see technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
45
Part number
Normal
G-type
Number of
conductors &
cross-section
n x mm2
Crosssection of
armour
mm2
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
–
–
–
–
–
–
27058
27060
27062
27064
27066
27068
27070
27072
27074
27076
27078
1x1,0
1x1,5
1x2,5
1x4
1x6
1x10
1x16 Flex
1x25 Flex
1x35 Flex
1x50 Flex
1x70 Flex
1x95 Flex
1x120 Flex
1x150 Flex
1x185 Flex
1x240 Flex
1x300 Flex
3,0
3,0
3,1
3,1
3,1
3,5
4,1
5,2
5,5
8,7
11,4
11,5
12,3
14,7
15,2
18,2
18,7
6,5
6,5
7,0
7,5
8,5
9,5
11,0
13,5
14,5
16,5
19,0
20,5
22,5
25,5
27,5
30,5
34,0
75
80
95
115
140
200
255
380
475
660
905
1125
1395
1735
2065
2710
3315
18
23
30
40
52
72
94
123
153
196
240
284
331
381
429
507
582
40
40
45
45
50
60
65
85
90
100
115
125
140
155
170
185
210
28542
28602
28604
28606
28608
28610
29071
29072
29073
29074
29075
29076
–
–
–
–
–
–
–
–
–
–
–
–
2x1,0
2x1,5
2x2,5
2x4
2x6
2x10
2x16 Flex
2x25 Flex
2x35 Flex
2x50 Flex
2x70 Flex
2x95 Flex
3,5
3,8
4,3
4,9
5,4
8,7
10,0
14,5
14,7
18,1
18,7
22,2
9,5
10,5
11,5
12,5
14,0
16,5
19,0
23,5
25,5
29,5
33,5
37,0
120
140
170
225
345
510
670
1035
1275
1715
2300
2900
15
20
26
34
44
61
80
105
130
167
204
241
60
65
70
75
85
100
115
145
155
180
205
225
28543
28622
28624
28626
28628
28630
29082
29084
29086
29088
29090
29092
29094
29096
29098
29100
28544
28623
28625
28627
28629
28631
29083
29085
29087
29089
29091
29093
29095
29097
29099
29101
3x1,0
3x1,5
3x2,5
3x4
3x6
3x10
3x16 Flex
3x25 Flex
3x35 Flex
3x50 Flex
3x70 Flex
3x95 Flex
3x120 Flex
3x150 Flex
3x185 Flex
3x240 Flex
4,1
4,1
4,6
5,2
5,8
9,3
10,7
14,6
15,0
17,5
22,0
22,8
37,8
39,3
47,9
50,7
10,0
11,0
12,0
13,5
14,5
17,5
20,0
25,0
27,0
31,5
36,0
40,0
45,0
51,0
56,0
63,0
145
170
210
280
400
605
800
1225
1550
2125
2900
3660
4710
5850
7145
9315
13
16
21
28
36
50
66
86
107
137
168
199
232
267
300
355
60
65
70
80
90
105
120
155
165
190
220
240
270
310
340
380
28545
28642
28644
28646
28648
28650
29104
29106
29108
29110
29112
29114
29116
29118
28546
28643
28645
28647
28649
28651
29105
29107
29109
29111
29113
29115
29117
29119
4x1,0
4x1,5
4x2,5
4x4
4x6
4x10
4x16 Flex
4x25 Flex
4x35 Flex
4x50 Flex
4x70 Flex
4x95 Flex
4x120 Flex
4x150 Flex
4,1
4,5
5,0
5,8
8,8
10,3
11,9
14,8
18,1
19,5
22,6
35,0
39,3
48,2
11,0
12,0
13,5
14,5
16,5
19,0
22,5
27,5
30,0
35,0
40,0
45,0
49,5
56,5
170
200
260
345
515
735
1010
1515
1960
2685
3655
4795
5980
7540
13
16
21
28
36
50
66
86
107
137
168
199
232
267
65
70
80
85
100
115
135
170
180
210
240
270
300
340
G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Table continues on next page
5/2016
28541
28568
28570
28572
28574
28576
29060
29061
29062
29063
29064
29065
29066
29067
29068
29069
29070
0,6/1kV CABLES
LKSM-FRHF 0,6/1kV
5/2016
0,6/1kV CABLES
46
LKSM-FRHF 0,6/1kV
Part number
Normal
G-type
Number of
conductors &
cross-section
n x mm2
Crosssection of
armour
mm2
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
28547
28662
28664
28705
28707
28709
29126
29128
29130
29132
28548
28663
28665
28706
28708
28710
29127
29129
29131
29133
5x1,0
5x1,5
5x2,5
5x4
5x6
5x10
5x16 Flex
5x25 Flex
5x35 Flex
5x50 Flex
4,5
5,0
5,6
8,6
9,7
11,5
13,2
18,1
18,6
22,4
12,0
13,0
14,5
16,5
18,0
21,0
24,5
30,5
33,0
38,5
195
245
305
445
605
880
1135
1740
2370
3240
10
13
17
23
30
42
55
71
89
114
70
80
85
100
105
125
150
185
200
230
28549
28551
28553
28555
28557
28559
28561
28563
28565
28550
28552
28554
28556
28558
28560
28562
28564
28566
7x1,0
10x1,0
12x1,0
14x1,0
16x1,0
19x1,0
24x1,0
27x1,0
37x1,0
4,9
8,7
9,0
11,4
11,4
11,4
12,5
12,8
14,4
13,0
16,5
17,0
18,0
19,0
20,0
23,5
24,0
26,5
240
355
395
455
505
555
695
750
960
9
8
8
7
7
7
6
6
5
80
100
100
105
115
120
140
145
160
28666
28723
28670
28727
28731
28674
28678
28682
28684
28667
28724
28671
28728
28732
28675
28679
28683
28685
7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
37x1,5
5,4
9,6
9,9
11,4
11,5
11,7
13,9
14,1
16,0
14,5
18,0
19,0
20,0
21,0
22,0
26,0
26,5
29,5
295
430
490
555
615
680
875
950
1220
12
11
10
10
9
9
8
8
7
85
110
115
120
125
130
155
160
180
28668
28725
28672
28729
28733
28676
28680
28686
28688
28669
28726
28673
28730
28734
28677
28681
28687
28689
7x2,5
12x2,5
10x2,5
14x2,5
16x2,5
19x2,5
24x2,5
27x2,5
37x2,5
8,5
11,5
11,5
11,8
12,5
13,2
15,7
16,1
18,1
16,0
20,0
21,0
22,5
23,5
24,5
29,0
29,5
33,0
405
570
635
735
820
920
1165
1270
1660
16
14
13
13
12
11
10
10
9
95
120
125
135
140
145
175
175
200
Other sizes on request.
G-type is with yellow/green earth conductor and
marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
47
0,6/1kV CABLES
5/2016
0,6/1kV CABLES
48
LKMSM-FRHF
5/2016
DESIGN:
Fire-resistant armoured power
cable with extruded filler
0,6/1kV
STANDARDS:
IEC 60092-353, design
1. Conductor
- stranded copper conductor 1,5–10mm2 IEC 60228, class 2
- stranded copper conductor 16–150mm2 IEC 60228, class 5
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic
IEC 60092-360
3. Bedding
- extruded filler
4. Armour
- copper wire braid, coverage > 90%
IEC 60092-350
- tinned copper wire braid and galvanized steel wire braid
on request
5. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-360
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships
and offshore units.
Main characteristics
Rated voltage
AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Fire-resistant
IEC 60331-1 or IEC 60331-2
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification: see technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
49
Crosssection of
armour
mm2
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Part number
Normal
G-type
Min. bending
radius fixed
installation
mm
–
–
–
–
–
–
–
–
–
2x1,5
2x2,5
2x4
2x6
2x10
2x16 Flex
2x25 Flex
2x35 Flex
2x50 Flex
5,3
5,8
6,6
9,8
11,4
13,0
16,1
17,2
20,0
13,0
13,0
15,0
16,5
18,0
20,5
25,5
26,5
30,5
215
255
315
410
550
695
990
1285
1695
20
26
34
44
61
80
105
130
167
75
80
90
95
110
125
150
160
185
29732
29734
29736
29738
29740
29743
29745
29747
29749
29751
29753
29755
29757
29733
29735
29737
29739
29741
29744
29746
29748
29750
29752
29754
29756
29758
3x1,5
3x2,5
3x4
3x6
3x10
3x16 Flex
3x25 Flex
3x35 Flex
3x50 Flex
3x70 Flex
3x95 Flex
3x120 Flex
3x150 Flex
5,7
6,3
9,4
10,4
12,1
13,9
17,1
18,4
21,4
25,2
38,3
42,7
48,9
13,5
14,0
16,0
16,5
19,0
21,5
27,0
29,0
33,0
38,5
42,5
46,5
53,0
245
300
395
490
675
865
1250
1620
2165
2985
3850
4775
5990
16
21
28
36
50
66
86
107
137
168
199
232
267
80
85
95
100
115
130
160
170
195
230
255
280
320
29767
29769
29771
29773
29775
29777
29779
29781
29783
29785
29787
29789
29768
29770
29772
29774
29776
29778
29780
29782
29784
29786
29788
29790
4x1,5
4x2,5
4x4
4x6
4x10
4x16 Flex
4x25 Flex
4x35 Flex
4x50 Flex
4x70 Flex
4x95 Flex
4x120 Flex
6,2
6,7
10,3
11,4
13,3
15,3
18,9
20,4
23,7
38,4
42,5
47,7
14,5
15,0
16,5
18,0
21,5
24,0
29,5
31,0
36,0
42,0
46,5
52,5
290
350
465
595
825
1080
1555
2015
2740
3845
4875
6085
16
21
28
36
50
66
86
107
137
168
199
232
85
90
100
110
125
145
175
190
220
255
280
315
29801
29803
29805
29807
29809
29811
29813
29802
29804
29806
29808
29810
29812
29814
5x1,5
5x2,5
5x4
5x6
5x10
5x16 Flex
5x25 Flex
6,7
10,1
11,2
12,5
14,6
16,8
20,9
15,5
17,0
18,0
19,5
22,5
26,0
31,5
335
435
555
700
985
1295
1890
13
17
23
30
42
55
71
90
100
110
120
135
160
190
Other sizes on request.
G-type is with yellow/green earth conductor and
marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
29715
29716
29717
29718
29719
29720
29721
29722
29723
0,6/1kV CABLES
conductors &
cross-section
n x mm2
LKMSM-FRHF 0,6/1kV Number of
0,6/1kV CABLES
50
LKAM-FRHF
DESIGN:
Fire-resistant screened power
and control cable 0,6/1kV
STANDARDS:
IEC 60092-353, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic
IEC 60092-360
5/2016
3. Screen
- drain wire of tinned copper 1,0mm2 (in all sizes)
- aluminium polyester tape,
IEC 60092-350
coverage 100%
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
4. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-360
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request
Application: For fixed installation in most areas and on open deck in ships and offshore
units, especially when lightweight cables are needed.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended.
Main characteristics
Rated voltage
AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Fire-resistant
IEC 60331-1 or IEC 60331-2
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification: see technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
51
Part number
Normal
G-type
–
28744
28748
28752
28756
28760
28764
28768
28772
28776
28780
28784
28788
–
28746
28750
28754
28758
28762
28766
28770
28774
28778
28782
28786
28790
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
2x1,5
3x1,5
4x1,5
5x1,5
7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
37x1,5
2x2,5
3x2,5
4x2,5
5x2,5
7x2,5
10x2,5
12x2,5
14x2,5
16x2,5
19x2,5
24x2,5
27x2,5
37x2,5
9,5
10,0
11,0
12,0
13,5
17,0
17,5
18,5
19,5
20,5
24,5
25,0
28,0
10,5
11,0
12,0
13,5
14,5
19,0
19,5
20,5
21,5
23,0
27,0
28,0
31,5
110
135
165
200
250
350
400
450
515
580
745
815
1070
140
175
215
270
335
485
555
630
705
825
1045
1145
1515
20
16
16
13
12
11
10
10
9
9
8
8
7
26
21
21
17
16
14
13
13
12
11
10
10
9
60
60
65
70
80
100
105
110
115
125
145
150
170
65
65
75
80
90
115
115
125
130
140
165
165
190
Other sizes on request.
G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
28741
28743
28747
28751
28755
28759
28763
28767
28771
28775
28779
28783
28787
28742
28745
28749
28753
28757
28761
28765
28769
28773
28777
28781
28785
28789
Number of
conductors &
cross-section
n x mm2
0,6/1kV CABLES
LKAM-FRHF 0,6/1kV
250V CABLES
52
LKM-HF
Unarmoured control and
instrumentation cable
250V
DESIGN:
STANDARDS:
IEC 60092-376, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-360
5/2016
3. Bedding
- separator tape
4. Sheath
- polyolefine plastic, SHF1
EC 60092-360
- on request, thermosetting polyolefine, SHF2
- standard colour grey, other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships and offshore
units.If the cable is exposed to direct sun light protective covering or cable
with black outer sheath is recommended..
Main characteristics
Rated voltage
150/250V (300V)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification: black numbers on white base
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
53
Part number
Nominal
outer
diameter
mm
2x0,5
3x0,5
4x0,5
5x0,5
7x0,5
10x0,5
12x0,5
14x0,5
16x0,5
19x0,5
20x0,5
24x0,5
27x0,5
32x0,5
37x0,5
2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
10x0,75
12x0,75
14x0,75
16x0,75
19x0,75
20x0,75
24x0,75
27x0,75
32x0,75
37x0,75
5,5
6,0
6,5
7,0
7,5
9,5
10,0
10,0
11,0
11,0
12,0
13,0
13,5
14,0
15,0
6,5
7,0
7,5
8,0
8,5
11,0
11,5
12,5
13,0
13,5
14,5
16,0
16,0
16,5
18,0
Other sizes on request.
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Approximate
weight kg/km
35
45
55
65
75
115
125
140
160
180
190
225
245
280
315
50
60
70
85
105
155
175
200
225
255
275
320
350
400
460
Current
Rating A
at +45°C
8,7
7,6
6,9
6,4
5,8
5,1
4,8
4,6
4,4
4,1
4,1
3,8
3,7
3,5
3,3
11,3
9,8
8,9
8,3
7,4
6,6
6,2
5,9
5,6
5,3
5,2
4,9
4,7
4,5
4,3
Min. bending
radius fixed
installation
mm
25
25
25
30
30
40
40
40
45
45
45
55
55
55
60
25
25
30
30
35
45
45
50
50
55
55
65
65
65
75
5/2016
27821
27822
27823
27824
27825
27826
27827
27828
27829
27830
27831
27832
27833
27834
27835
26365
26366
26367
26368
26369
26370
26371
26372
26373
26374
26375
26376
26377
26378
26379
Number of
conductors &
cross-section
n x mm2
250V CABLES
LKM-HF 250V
250V CABLES
54
LKSM-HF
Armoured control and
instrumentation cable
250V
5/2016
DESIGN:
STANDARDS:
IEC 60092-376, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-360
3. Bedding
- separator tape
4. Armour
- drain wire copper (in all sizes)
- copper wire braid, coverage > 90%
IEC 60092-350
- tinned copper wire braid on request
-the armour serves as a collective screen
5. Sheath
- polyolefine plastic, SHF1
EC 60092-360
- on request, thermosetting polyolefine, SHF2
- standard colour grey, other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships and offshore
units. If the cable is exposed to direct sun light protective covering or cable
with black outer sheath is recommended.
Main characteristics
Rated voltage
150/250V (300V)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification: black numbers on white base
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
55
Part number
2x0,5
3x0,5
4x0,5
5x0,5
7x0,5
10x0,5
12x0,5
14x0,5
16x0,5
19x0,5
20x0,5
24x0,5
27x0,5
32x0,5
37x0,5
2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
10x0,75
12x0,75
14x0,75
16x0,75
19x0,75
20x0,75
24x0,75
27x0,75
32x0,75
37x0,75
Other sizes on request.
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Crosssection of
armour
mm2
3,0
3,0
2,6
3,1
3,2
4,2
4,3
4,5
5,3
5,3
5,5
6,1
6,3
8,9
9,7
3,1
3,1
3,2
3,6
3,9
5,3
5,3
5,6
5,9
6,3
10,9
10,2
10,5
10,9
11,8
Nominal
outer
diameter
mm
6,5
7,0
7,5
8,0
8,5
10,5
10,5
11,0
11,5
12,5
13,0
14,0
14,5
15,0
16,0
7,5
7,5
8,0
9,5
10,0
12,0
12,5
13,0
13,5
14,5
18,0
17,0
17,5
18,0
19,5
Approximate
weight kg/km
75
80
85
100
115
160
175
195
215
240
260
290
315
380
425
85
95
110
135
155
215
235
260
290
320
440
425
460
520
580
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
8,7
7,6
6,9
6,4
5,8
5,1
4,8
4,6
4,4
4,1
4,1
3,8
3,7
3,5
3,3
11,3
9,8
8,9
8,3
7,4
6,6
6,2
5,9
5,6
5,3
5,2
4,9
4,7
4,5
4,3
40
40
45
45
50
60
65
65
70
75
80
85
85
90
95
45
45
50
55
60
75
75
80
80
85
105
100
105
110
115
5/2016
27779
27780
27781
27782
27783
27784
27785
27786
27787
27788
27789
27790
27791
27792
27793
26402
26403
26404
26405
26407
26410
26412
26414
26416
26419
26420
26424
26427
26432
26437
Number of
conductors &
cross-section
n x mm2
250V CABLES
LKSM-HF 250V
250V CABLES
56
LKAM-HF
Screened control and
instrumentation cable
250V
DESIGN:
STANDARDS:
IEC 60092-376, design
5/2016
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-360
3. Screen
- drain wire of tinned copper
- aluminium polyester tape,
coverage 100%
IEC 60092-350
4. Sheath
- polyolefine plastic, SHF1
EC 60092-360
- on request, thermosetting polyolefine, SHF2
- standard colour grey, other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships and offshore
units, especially when lightweight cables are needed.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended.
Main characteristics
Rated voltage
150/250V (300V)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification: black numbers on white base
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
57
Part number
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
2x0,5
3x0,5
4x0,5
5x0,5
7x0,5
10x0,5
12x0,5
14x0,5
16x0,5
19x0,5
20x0,5
24x0,5
27x0,5
32x0,5
37x0,5
2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
10x0,75
12x0,75
14x0,75
16x0,75
19x0,75
20x0,75
24x0,75
27x0,75
32x0,75
37x0,75
5,5
6,0
6,5
7,0
7,5
9,5
10,0
10,5
11,0
11,5
12,0
13,0
13,5
14,0
15,0
6,5
7,0
7,5
8,0
9,0
11,0
12,0
12,5
13,0
13,5
14,5
16,0
16,0
17,0
18,0
40
50
60
70
80
120
130
145
165
185
205
230
250
290
330
55
65
75
90
120
160
185
205
230
260
285
325
355
415
465
8,7
7,6
6,9
6,4
5,8
5,1
4,8
4,6
4,4
4,1
4,1
3,8
3,7
3,5
3,3
11,3
9,8
8,9
8,3
7,4
6,6
6,2
5,9
5,6
5,3
5,2
4,9
4,7
4,5
4,3
25
25
25
30
30
40
40
40
45
45
50
55
55
55
60
25
30
30
30
35
45
45
50
50
55
60
65
65
70
75
Other sizes on request.
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
26440
26441
26442
26443
26444
26445
26446
26447
26448
26449
26450
26451
26452
26453
26454
26382
26383
26384
26385
26386
26387
26388
26389
26390
26391
26392
26393
26394
26395
26396
Number of
conductors &
cross-section
n x mm2
250V CABLES
LKAM-HF 250V
250V CABLES
58
RFE-HF
Armoured pair instrumentation
and communication cable
250V
5/2016
DESIGN:
STANDARDS:
IEC 60092-376, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-360
3. Twisted pair
- two insulated cores twisted together to form a pair
See next page for Quad
4. Bedding
- filler tape
5. Armour
- drain wire copper (in all sizes)
- copper wire braid, coverage > 94%
IEC 60092-350
- tinned copper wire braid on request
- the armour serves as a collective screen
6. Sheath
- polyolefine plastic, SHF1
EC 60092-360
- on request, thermosetting polyolefine, SHF2
- standard colour grey, other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships and offshore
units. If the cable is exposed to direct sun light protective covering or cable
with black outer sheath is recommended.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant
150/250V (300V)
Halogen-free
Smoke emission
+ 90 °C
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
IEC 60754 series
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Electrical data:
Loop resistance of pair, max. / +20°C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20°C
0,5mm2 0,75mm2
80
52
55
50
0,6
0,6
≥1500
≥1500
1,5mm2
24,4
60
0,7
≥1500
Unit
ohm/km
nF/km
mH/km
Mohm/km
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
59
Part number
Nominal
outer
diameter
mm
Approximate
weight kg/km
Min. bending
radius fixed
installation
mm
6,5
7,5
9,5
10,5
12,5
13,5
15,5
16,0
17,0
18,0
19,0
21,5
7,5
8,5
11,0
12,5
15,0
16,0
18,0
19,0
20,0
21,5
23,0
25,5
29,0
10,0
10,5
14,5
17,0
20,0
21,5
24,5
26,0
27,5
29,0
31,5
35,0
40,0
75
90
120
155
220
240
315
350
390
435
490
600
90
115
150
205
290
350
425
475
530
600
680
820
1035
140
185
235
380
555
635
770
865
975
1095
1250
1555
1980
40
45
55
65
75
80
90
95
100
110
115
130
45
50
65
75
90
95
110
115
120
130
140
155
175
60
65
85
100
120
130
150
155
165
175
190
210
240
1x2x0,5
1x2x0,5 Quad
2x2x0,5
4x2x0,5
7x2x0,5
8x2x0,5
10x2x0,5
12x2x0,5
14x2x0,5
16x2x0,5
19x2x0,5
24x2x0,5
1x2x0,75
1x4x0,75 Quad
2x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
16x2x0,75
19x2x0,75
24x2x0,75
32x2x0,75
1x2x1,5
1x2x1,5 Quad
2x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
16x2x1,5
19x2x1,5
24x2x1,5
32x2x1,5
Other sizes on request.
Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
(Quad)cable is built up as a star quad
with the following identification
1 core
white
2 core
blue
3 core
white
4 core
blue
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
20362
20364
20363
20366
20368
20369
20370
20371
20372
20373
20374
20376
20382
20384
20383
20386
20388
20389
20390
20391
20392
20393
20394
20396
20398
20490
20491
20492
20493
20494
20495
20496
20497
20498
20503
20499
20500
20501
Number of
conductors &
cross-section
n x mm2
250V CABLES
RFE-HF 250V
250V CABLES
60
RFE-HF (i)
5/2016
DESIGN:
Armoured and individually screened
instrumentation and communication cable
250V
STANDARDS:
IEC 60092-376, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-360
3. Twisted pair & individual screen
- two insulated cores twisted together to form a pair
- plastic coated aluminium tape and a tinned copper drain wire
4. Bedding
- filler tape
5. Armour
- drain wire copper (in all sizes)
- copper wire braid, coverage > 94%
IEC 60092-350
- tinned copper wire braid on request
6. Sheath
- polyolefine plastic, SHF1
IEC 60092-360
- on request, thermosetting polyolefine, SHF2
- standard colour grey, other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships and offshore
units. If the cable is exposed to direct sun light protective covering or cable
with black outer sheath is recommended.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant
150/250V (300V)
Halogen-free
Smoke emission
+ 90 °C
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
IEC 60754 series
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Electrical data:
Loop resistance of pair, max. / +20°C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20°C
0,5mm2 0,75mm2
80
52
55
70
0,6
0,6
≥1500
≥1500
1,5mm2
24,4
90
0,7
≥1500
Unit
ohm/km
nF/km
mH/km
Mohm/km
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
61
Approximate
weight kg/km
Min. bending
radius fixed
installation
mm
22338
22342
22344
22346
22348
22350
22352
22354
22356
22358
22360
22362
22364
22366
22368
22370
22372
1x2x0,5
2x2x0,5 Quad
2x2x0,5
3x2x0,5
4x2x0,5
7x2x0,5
8x2x0,5
10x2x0,5
12x2x0,5
14x2x0,5
16x2x0,5
19x2x0,5
24x2x0,5
27x2x0,5
30x2x0,5
32x2x0,5
37x2x0,5
7,0
7,5
9,5
10,0
11,0
13,0
13,5
15,5
16,5
17,5
18,5
19,5
22,0
23,0
24,0
24,5
26,5
85
115
140
165
205
295
325
420
475
540
600
685
855
940
1020
1075
1225
40
45
60
60
65
75
80
95
100
105
110
120
135
140
145
150
160
22006
22008
22010
22012
22014
22016
22018
22020
22022
22024
22026
22028
22050
22052
22054
22056
22058
22060
22062
22064
22066
22068
22070
22072
1x2x0,75
2x2x0,75 Quad
2x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
19x2x0,75
24x2x0,75
32x2x0,75
1x2x1,5
2x2x1,5 Quad
2x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
19x2x1,5
24x2x1,5
32x2x1,5
7,5
8,5
11,0
13,0
15,5
16,5
18,5
19,5
21,0
23,5
26,0
30,0
10,0
11,0
14,5
17,0
20,5
22,0
25,0
26,0
28,0
32,0
36,0
41,0
95
125
165
235
365
400
485
550
635
810
980
1255
150
205
255
415
615
705
860
975
1110
1450
1785
2395
45
50
65
75
95
100
110
115
125
140
155
180
60
65
85
105
120
130
150
155
170
195
215
245
Part number
Other sizes on request.
Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....)
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
Nominal
outer
diameter
mm
250V CABLES
Number of
conductors &
cross-section
n x mm2
RFE-HF(i) 250V
250V CABLES
62
RFA-HF
Screened pair instrumentation
and communication cable
250V
5/2016
DESIGN:
STANDARDS:
IEC 60092-376, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-360
3. Twisted pair
- two insulated cores twisted together to form a pair
See next page for Quad
4. Collective screen
- drain wire tinned copper
- aluminium polyester tape
IEC 60092-350
coverage 100%
5. Sheath
- polyolefine plastic, SHF1
EC 60092-360
- on request, thermosetting polyolefine, SHF2
- standard colour grey, other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships and offshore
units, especially when lightweight cables are needed. If the cable is exposed
to direct sun light protective covering or cable with black outer sheath is
recommended.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant
Halogen-free
Smoke emission
Oil resistance (only SHF2)
150/250V (300V)
+ 90 °C
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
IEC 60754 series
IEC 61034 series
IEC 60811-404 conditions according to 60092-360/SHF2
Electrical data
Loop resistance of pair, max. / +20°C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20°C
0,5mm2 0,75mm2
80
52
55
50
0,6
0,6
≥1500
≥1500
1,5mm2
24,4
60
0,7
≥1500
Unit
ohm/km
nF/km
mH/km
Mohm/km
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
63
Part number
Nominal
outer
diameter
mm
1x2x0,5
2x2x0,5 Quad
2x2x0,5
3x2x0,5
4x2x0,5
7x2x0,5
8x2x0,5
10x2x0,5
12x2x0,5
14x2x0,5
16x2x0,5
19x2x0,5
24x2x0,5
32x2x0,5
37x2x0,5
1x2x0,75
2x2x0,75 Quad
2x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
16x2x0,75
19x2x0,75
24x2x0,75
32x2x0,75
37x2x0,75
1x2x1,5
2x2x1,5 Quad
2x2x1,5
3x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
16x2x1,5
19x2x1,5
24x2x1,5
27x2x1,5
30x2x1,5
32x2x1,5
37x2x1,5
5,5
6,5
8,0
9,0
9,5
11,5
12,5
14,0
14,5
15,5
16,5
18,0
20,0
23,0
24,5
6,5
7,5
10,0
11,5
14,0
15,0
17,0
17,5
19,0
20,5
22,0
24,0
27,5
30,0
8,5
10,0
13,5
14,0
15,5
18,5
20,0
23,0
24,5
26,0
27,5
30,0
33,5
35,5
37,5
38,5
41,0
Approximate
weight kg/km
Min. bending
radius fixed
installation
mm
40
60
70
90
110
155
180
220
250
280
310
365
460
590
665
55
75
95
145
220
250
310
355
400
465
530
655
845
980
85
140
170
215
265
415
475
600
685
795
890
1045
1305
1465
1600
1715
1945
35
40
50
55
60
70
75
85
90
95
100
105
120
135
145
40
45
60
70
85
90
100
105
115
120
130
145
165
180
50
60
80
85
90
110
120
140
145
155
165
180
200
215
225
230
245
Other sizes on request.
Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
(Quad)cable is built up as a star quad
with the following identification
1 core
white
2 core
blue
3 core
white
4 core
blue
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
20910
20912
20914
20906
20916
20918
20920
20922
20924
20926
20928
20930
20932
20934
20936
20970
20972
20974
20976
20978
20980
20982
20984
20986
20988
20990
20992
20994
20996
21356
21358
21359
21360
21361
21362
21363
21364
21365
21366
21367
21368
21369
21370
21371
21372
21373
Number of
conductors &
cross-section
n x mm2
250V CABLES
RFA-HF 250V
250V CABLES
64
RFA-HF (i)
5/2016
DESIGN:
Collectively and individually
screened instrumentation and
communication cable 250 V
STANDARDS:
IEC 60092-376, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-360
3. Twisted pair & individual screen
- two insulated cores twisted together to form a pair
- plastic coated aluminium tape and a tinned copper drain wire
4. Bedding
- separator tape
5. Collective screen
- drain wire tinned copper
IEC 60092-350
- aluminium polyester tape, coverage 100%
6. Sheath
- polyolefine plastic, SHF1
EC 60092-360
- on request, thermosetting polyolefine, SHF2
- standard colour grey, other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships and offshore
units, especially when lightweight cables are needed. If the cable is exposed
to direct sun light protective covering or cable with black outer sheath is
recommended.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant
Halogen-free
Smoke emission
Oil resistance (only SHF2)
150/250V (300V)
+ 90 °C
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
IEC 60754 series
IEC 61034 series
IEC 60811-404 conditions according to 60092-360/SHF2
Electrical data
Loop resistance of pair, max. / +20°C
Pair capacitance, nom.
Loop inductance, nom.
Insulation resistance / +20°C
0,5mm2 0,75mm2
80
52
55
70
0,6
0,6
≥1500
≥1500
1,5mm2
24,4
90
0,7
≥1500
Unit
ohm/km
nF/km
mH/km
Mohm/km
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
65
Part number
2x2x0,5
4x2x0,5
7x2x0,5
8x2x0,5
10x2x0,5
12x2x0,5
14x2x0,5
16x2x0,5
19x2x0,5
24x2x0,5
32x2x0,5
37x2x0,5
1x2x0,75
2x2x0,75
3x2x0,75
4x2x0,75
5x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
16x2x0,75
19x2x0,75
24x2x0,75
1x2x1,5
2x2x1,5 Quad
2x2x1,5
3x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
16x2x1,5
19x2x1,5
24x2x1,5
27x2x1,5
30x2x1,5
32x2x1,5
37x2x1,5
Nominal
outer
diameter
mm
Approximate
weight kg/km
Min. bending
radius fixed
installation
mm
8,5
10,0
12,0
12,5
14,5
15,0
16,0
17,0
18,5
20,5
23,5
25,0
6,5
10,0
10,5
11,5
13,0
14,0
15,0
17,0
18,0
19,0
20,5
22,0
24,5
8,5
10,0
13,5
14,0
16,0
19,0
20,5
23,5
25,0
26,5
28,5
30,5
34,5
36,5
38,0
39,5
42,0
80
130
200
225
280
320
360
405
475
600
775
880
60
110
140
170
205
260
300
370
425
485
560
645
800
95
155
190
240
310
485
565
695
805
915
1045
1210
1535
1715
1885
2030
2305
50
60
70
75
85
90
95
100
110
125
140
150
40
60
65
70
75
85
90
105
110
115
125
135
150
50
60
80
85
95
115
125
140
150
160
170
185
205
220
230
235
250
Other sizes on request.
Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
The pairs are covered by a numbered tape (1, 2, 3, 4, 5....)
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
20940
20942
20944
20946
20948
20950
20952
20954
20956
20958
20960
20962
21058
21059
21100
21061
21115
21063
21065
21067
21069
21071
21073
21075
21077
21375
21377
21378
21379
21380
21381
21382
21383
21384
21385
21386
21387
21388
21389
21390
21391
21392
Number of
conductors &
cross-section
n x mm2
250V CABLES
RFA-HF(i) 250V
250V CABLES
66
LKM-FRHF
DESIGN:
Fire-resistant unarmoured
control and instrumentation
cable 250V
STANDARDS:
IEC 60092-376, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic
IEC 60092-360
5/2016
3. Bedding
- separator tape
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
4. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-360
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request
Application: For fixed installation in most areas and on open deck in ships and offshore
units. If the cable is exposed to direct sun light protective covering or cable
with black outer sheath is recommended.
Main characteristics
Rated voltage
150/250V (300V)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Fire-resistant
IEC 60331-1 or IEC 60331-2
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification: black numbers on white base
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
67
Part number
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
10x0,75
12x0,75
14x0,75
16x0,75
19x0,75
20x0,75
24x0,75
27x0,75
32x0,75
37x0,75
8,0
8,5
9,5
10,5
11,5
14,5
15,0
16,0
17,0
18,0
19,0
21,0
21,5
22,5
24,5
65
80
95
125
155
220
250
280
315
365
395
460
500
575
675
11,3
9,8
8,9
8,3
7,4
6,6
6,2
5,9
5,6
5,3
5,2
4,9
4,7
4,5
4,3
35
35
40
45
45
60
60
65
65
70
75
85
85
90
100
Other size on request.
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
22406
22407
22408
22409
22410
22411
22412
22413
22414
22415
22416
22417
22418
22419
22420
Number of
conductors &
cross-section
n x mm2
250V CABLES
LKM-FRHF 250V
250V CABLES
68
LKSM-FRHF
DESIGN:
Fire-resistant armoured
control and instrumentation
cable 250V
STANDARDS:
IEC 60092-376, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic
EC 60092-360
5/2016
3. Bedding
- separator tape
4. Armour
- drain wire copper (in all sizes)
- copper wire braid, coverage > 90%
- tinned copper wire braid on request
IEC 60092-350
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
5. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-360
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request
Application: For fixed installation in most areas and on open deck in ships and offshore
units. If the cable is exposed to direct sun light protective covering or cable
with black outer sheath is recommended.
Main characteristics
Rated voltage
150/250V (300V)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Fire-resistant
IEC 60331-1 or IEC 60331-2
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification: black numbers on white base
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
69
Part number
2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
10x0,75
12x0,75
14x0,75
16x0,75
19x0,75
20x0,75
24x0,75
27x0,75
32x0,75
37x0,75
Other size on request.
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Crosssection of
armour
mm2
3,1
3,9
4,3
4,8
5,3
6,9
7,2
7,6
11,1
11,7
12,6
14,0
14,3
14,9
16,2
Nominal
outer
diameter
mm
9,0
9,5
10,5
11,5
12,5
15,5
16,0
16,5
18,0
19,0
20,0
22,0
22,5
23,5
25,5
Approximate
weight kg/km
100
125
155
180
210
290
325
360
435
480
530
600
645
720
830
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
11,3
9,8
8,9
8,3
7,4
6,6
6,2
5,9
5,6
5,3
5,2
4,9
4,7
4,5
4,3
55
55
65
70
75
95
95
100
110
115
120
130
135
140
155
5/2016
22436
22437
22438
22439
22440
22441
22442
22443
22444
22445
22446
22447
22448
22449
22450
Number of
conductors &
cross-section
n x mm2
250V CABLES
LKSM-FRHF 250V
250V CABLES
70
LKAM-FRHF
DESIGN:
Fire-resistant screened control
and instrumentation cable
250V
STANDARDS:
IEC 60092-376, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
5/2016
2. Insulation
- Mica tape
- XLPE plastic
IEC 60092-360
3. Screen
- drain wire of tinned copper
- aluminium polyester tape,
coverage 100%
IEC 60092-350
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
4. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-360
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request
Application: For fixed installation in most areas and on open deck in ships and offshore
units, especially when lightweight cables are needed.If the cable is exposed
to direct sun light protective covering or cable with black outer sheath is
recommended.
Main characteristics
Rated voltage
150/250V (300V)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Fire-resistant
IEC 60331-1 or IEC 60331-2
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Core identification: black numbers on white base
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
71
Part number
2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
10x0,75
12x0,75
14x0,75
16x0,75
19x0,75
20x0,75
24x0,75
27x0,75
32x0,75
37x0,75
Other size on request.
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Nominal
outer
diameter
mm
8,0
8,5
10,0
10,5
11,5
14,5
15,0
16,0
17,0
18,0
19,0
21,0
21,5
22,5
24,5
Approximate
weight kg/km
70
85
110
135
160
225
255
295
330
370
400
465
510
600
680
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
11,3
9,8
8,9
8,3
7,4
6,6
6,2
5,9
5,6
5,3
5,2
4,9
4,7
4,5
4,3
50
50
60
65
70
90
90
95
100
105
115
125
130
135
145
5/2016
22466
22467
22468
22469
22470
22471
22472
22473
22474
22475
22476
22477
22478
22479
22480
Number of
conductors &
cross-section
n x mm2
250V CABLES
LKAM-FRHF 250V
250V CABLES
72
RFE-FRHF
Fire-resistant armoured pair
instrumentation and communication cable
250V
5/2016
DESIGN:
STANDARDS:
IEC 60092-376, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic
IEC 60092-360
3. Twisted pair
- two insulated cores twisted together to form a pair
See next page for Quad
4. Bedding
- filler tape
5. Armour
- drain wire (in all sizes)
- copper wire braid, coverage > 94%
IEC 60092-350
- tinned copper wire braid on request
- the armour serves as a collective screen
6. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-360
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships and offshore
units. If the cable is exposed to direct sun light protective covering or cable
with black outer sheath is recommended.
Main characteristics
Rated voltage
150/250V (300V)
Maximum conductor
temperature
+ 90 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
Fire-resistant
Halogen-free
Smoke emission
IEC 60331-1 or IEC 60331-2
IEC 60754 series
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
Electrical data
Loop resistance of pair, max. / +20°C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20°C
0,75mm2 1,5mm2
52
24,4
45
55
0,6
0,7
≥1500
≥1500
Unit
ohm/km
nF/km
mH/km
Mohm/km
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
73
Part number
Nominal
outer
diameter
mm
1x2x0,75
2x2x0,75 Quad
2x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
19x2x0,75
24x2x0,75
32x2x0,75
37x2x0,75
1x2x1,5
2x2x1,5 Quad
2x2x1,5
3x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
16x2x1,5
19x2x1,5
24x2x1,5
32x2x1,5
37x2x1,5
Other sizes on request.
Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
(Quad)cable is built up as a star quad
with the following identification
1 core
white
2 core
blue
3 core
white
4 core
blue
9,0
11,0
14,0
16,0
19,5
21,0
24,0
25,0
26,5
30,5
34,0
38,5
41,0
10,5
12,0
16,0
17,0
18,5
22,5
24,0
27,0
28,5
30,5
32,5
35,0
39,0
44,5
47,5
Approximate
weight kg/km
Min. bending
radius fixed
installation
mm
115
170
200
285
445
495
615
685
765
970
1205
1520
1700
155
220
300
355
425
650
715
875
1000
1125
1280
1460
1795
2410
2730
55
65
85
95
115
125
145
150
160
180
205
230
245
65
70
95
100
110
135
145
160
170
180
195
210
235
270
285
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
20520
20522
20524
20526
20528
20530
20532
20534
20536
20538
20540
20542
20543
20575
20577
20579
20574
20581
20583
20585
20587
20589
20591
20593
20595
20597
20599
20601
Number of
conductors &
cross-section
n x mm2
250V CABLES
RFE-FRHF 250V
250V CABLES
74
RFE-FRHF (i)
5/2016
DESIGN:
Armoured and individually screened
instrumentation and communication cable
250V
STANDARDS:
IEC 60092-376, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
Flame- Mica tape
retardant
- XLPE plastic
IEC 60092-360
Fire3. Twisted pair & individual screen
resistant
- two insulated cores twisted together to form a pair
Halogen- plastic coated aluminium tape and a tinned copper drain wire
free
4. Bedding
Low smoke
- filler tape
emission
5. Armour
Oil resistant
- drain wire copper
(only SHF2)
- copper wire braid, coverage > 94%
IEC 60092-350
- tinned copper wire braid on request
6. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-360
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request
Application: For fixed installation in most areas and on open deck in ships and offshore
units. If the cable is exposed to direct sun light protective covering or cable
with black outer sheath is recommended.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant
Fire-resistant
Halogen-free
Smoke emission
Oil resistance (only SHF2)
150/250V (300V)
+ 90 °C
IEC 60332-1-2
IEC 60332-3-22
-test for single insulated wire and cable
-test for bunched wires and cables,
category A
IEC 60331-1 or IEC 60331-2
IEC 60754 series
IEC 61034 series
IEC 60811-404 conditions according to 60092-360/SHF2
Electrical data
Loop resistance of pair, max. / +20°C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20°C
0,75mm2 1,5mm2
52
24,4
55
75
0,6
0,7
≥1500
≥1500
Unit
ohm/km
nF/km
mH/km
Mohm/km
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
75
Part number
2x2x0,75
2x2x0,75 Quad
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
19x2x0,75
24x2x0,75
32x2x0,75
1x2x1,5
2x2x1,5 Quad
2x2x1,5
4x2x1,5
7x2x1,5
1x2x1,5
2x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
16x2x1,5
19x2x1,5
Nominal
outer
diameter
mm
Approximate
weight kg/km
Min. bending
radius fixed
installation
mm
14,0
11,0
16,5
20,0
21,0
24,5
25,5
27,0
31,0
35,0
39,5
10,5
12,0
16,0
19,0
22,5
10,5
16,0
19,0
22,5
24,0
27,5
29,0
31,0
33,0
35,5
215
170
345
495
545
675
770
865
1105
1370
1735
160
225
315
470
710
160
315
470
710
795
970
1130
1275
1430
1640
85
65
100
120
125
145
155
165
185
210
235
65
70
95
115
135
65
95
115
135
145
165
175
185
200
215
Other sizes on request.
Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....)
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
20550
20548
20552
20554
20556
20558
20560
20562
20564
20566
20568
20603
20604
20605
20607
20609
20603
20605
20607
20609
20611
20613
20615
20617
20619
20621
Number of
conductors &
cross-section
n x mm2
250V CABLES
RFE-FRHF(i) 250V
250V CABLES
76
RFA-FRHF
Fire-resistant screened pair
instrumentation and
communication cable 250V
5/2016
DESIGN:
STANDARDS:
IEC 60092-376, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic
IEC 60092-360
3. Twisted pair
- two insulated cores twisted together to form a pair
See next page for Quad
4. Collective screen
- drain wire tinned copper
- aluminium polyester tape, coverage 100% IEC 60092-350
5. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-360
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships and offshore
units. If the cable is exposed to direct sun light protective covering or cable
with black outer sheath is recommended.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant
150/250V (300V)
+ 90 °C
IEC 60332-1-2
IEC 60332-3-22
-test for single insulated wire and cable
-test for bunched wires and cables,
category A
Fire-resistant
IEC 60331-1 or IEC 60331-2
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
For details see general information section
Electrical data
Loop resistance of pair, max. / +20°C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20°C
0,75mm2 1,5mm2
52
24,4
45
55
0,6
0,7
≥1500
≥1500
Unit
ohm/km
nF/km
mH/km
Mohm/km
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
77
Part number
Nominal
outer
diameter
mm
Approximate
weight kg/km
Min. bending
radius fixed
installation
mm
8,0
9,5
13,0
15,0
18,0
19,5
22,5
23,5
25,5
27,0
29,0
32,5
9,0
14,5
14,5
15,5
17,0
20,5
22,5
26,0
27,0
29,0
31,0
33,5
37,5
39,5
42,0
43,0
46,0
70
105
135
210
315
355
435
500
590
655
770
950
95
185
190
245
310
485
560
695
800
925
1035
1230
1535
1695
1900
2005
2295
50
55
75
90
110
115
135
140
150
160
175
195
55
85
85
90
105
125
135
155
160
175
185
200
225
235
250
260
275
1x2x0,75
2x2x0,75 Quad
2x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
16x2x0,75
19x2x0,75
24x2x0,75
1x2x1,5
2x2x1,5 Quad
2x2x1,5
3x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
16x2x1,5
19x2x1,5
24x2x1,5
27x2x1,5
30x2x1,5
32x2x1,5
37x2x1,5
Other sizes on request.
Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
(Quad)cable is built up as a star quad
with the following identification
1 core
white
2 core
blue
3 core
white
4 core
blue
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
20635
20637
20639
20641
20643
20645
20647
20649
20651
20653
20655
20657
21521
21524
21525
21526
21527
21529
21531
21533
21535
21537
21539
21541
21542
21543
21544
21545
21547
Number of
conductors &
cross-section
n x mm2
250V CABLES
RFA-FRHF 250V
250V CABLES
78
RFA-FRHF (i)
Collectively and individually
screened instrumentation and
communication cable 250 V
5/2016
DESIGN:
STANDARDS:
IEC 60092-376, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic
IEC 60092-360
3. Twisted pair & individual screen
- two insulated cores twisted together to form a pair
- plastic coated aluminium tape and a tinned copper drain wire
4. Bedding
- separator tape
5. Collective screen
- drain wire tinned copper
- aluminium polyester tape coverage 100 % IEC 60092-350
6. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-360
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
Application: For fixed installation in most areas and on open deck in ships and offshore
units. If the cable is exposed to direct sun light protective covering or cable
with black outer sheath is recommended.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant
150/250V (300V)
+ 90 °C
IEC 60332-1-2
IEC 60332-3-22
-test for single insulated wire and cable
-test for bunched wires and cables,
category A
Fire-resistant
IEC 60331-1 or IEC 60331-2
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance (only SHF2)
IEC 60811-404 conditions according to 60092-360/SHF2
For details see general information section
Electrical data
Loop resistance of pair, max. / +20°C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20°C
0,75mm2 1,5mm2
52
24,4
55
75
0,6
0,7
≥1500
≥1500
Unit
ohm/km
nF/km
mH/km
Mohm/km
Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, manufacturer's name, production month and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
79
Part number
1x2x0,75
2x2x0,75 Quad
2x2x0,75
3x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
16x2x0,75
19x2x0,75
24x2x0,75
32x2x0,75
37x2x0,75
1x2x1,5
2x2x1,5 Quad
2x2x1,5
3x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
16x2x1,5
19x2x1,5
24x2x1,5
27x2x1,5
30x2x1,5
32x2x1,5
37x2x1,5
Nominal
outer
diameter
mm
Approximate
weight kg/km
Min. bending
radius fixed
installation
mm
8,5
9,5
13,0
14,0
15,5
18,5
20,0
23,0
24,0
25,5
27,5
29,5
33,5
38,0
40,5
9,0
11,0
14,5
16,0
17,5
21,0
23,0
26,5
27,5
29,5
31,5
34,0
38,5
40,5
42,5
44,0
47,0
80
110
145
190
235
365
415
525
600
680
775
895
1135
1465
1680
105
170
210
280
345
545
635
800
920
1050
1205
1415
1785
1980
2190
2315
2675
50
55
80
85
90
110
120
140
145
155
165
175
200
230
245
55
65
90
95
105
125
135
160
165
175
190
205
230
245
255
265
280
Other sizes on request.
Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....)
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
5/2016
20664
20666
20667
20668
20669
20671
20673
20675
20677
20679
20681
20683
20685
20687
20689
21550
21552
21553
21554
21555
21557
21559
21561
21563
21565
21567
21569
21571
21572
21573
21574
21575
Number of
conductors &
cross-section
n x mm2
250V CABLES
RFA-FRHF(i) 250V
5/2016
LKSM-SHF2 120°C
0,6/1kV
80
LKSM-SHF2 120°C
Heat and oil resistant armoured power and control cable 0,6/1kV
DESIGN:
STANDARDS:
IEC 60092-353, design
1. Conductor
- stranded copper conductor 1,0-10mm2 IEC 60228, class 2
- stranded copper conductor 16-300mm2 IEC 60228, class 5 (Flex)
- tinned stranded copper conductor on request
2. Insulation
- improved heat resistant XLPE (+120°C) IEC 60092-360
3. Bedding
- filler tape
4. Armour
- copper wire braid, coverage > 90%
IEC 60092-350
- tinned copper wire braid on request
5. Sheath
- improved heat resistant SHF2 (+120°C) IEC 60092-360
- standard colour black with grey stripes, other colours on request
+120°C heat
resistant
Oil resistant
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Application: For fixed installation in most areas and on open deck in ships or on oil rigs and
various industrial use. Excellent resistance against weathering, ozone, UV-rays, Oil / Diesel oil.
Typical Marine, Oil, Gas and Petrochemical applications are for example Ship Engine rooms,
power plants and/or other areas where ambient temperature may exceed +80°C, which is the
limit for traditional IEC 60092-cables.
Rated voltage
AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)
Oil resistance
IEC 60811-404 conditions according to 60092-360
Halogen-free
IEC 60754 series
Flame-retardant
IEC 60332-1-2 Test for single insulated wire and cable
IEC 60332-3-22 Test for bunched wires and cables, category A
Smoke emission
IEC 61034 series
Temperature rating:
Fixed installation:
-40ºC to +120ºC
Occasionally moved:
-20ºC to +120ºC
Max. conductor temperature: +120ºC
Core identification:
See technical information section
Sheath marking: Lot number, cable type, cable size, voltage, temperature, standards,
manufacturer's name, production month and meter marking printed on the sheath
The cable is marine type approved by all major classification societies. Cable name on type approval
certificate is LKSM-SHF2.
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
81
Number of
conductors &
cross-section
n x mm2
Crosssection of
armour
mm2
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
1x1,0
1x1,5
1x2,5
1x4
1x6
1x10
1x16 Flex
1x25 Flex
1x35 Flex
1x50 Flex
1x70 Flex
1x95 Flex
1x120 Flex
1x150 Flex
1x185 Flex
1x240 Flex
1x300 Flex
3,0
3,0
2,5
3,1
3,1
3,6
4,1
4,9
5,5
8,7
11,4
11,5
14,5
14,7
15,2
18,2
18,7
6,0
6,5
7,0
7,5
8,0
9,5
10,5
13,0
14,0
16,0
18,5
20,0
22,5
25,0
27,0
30,5
34,0
65
75
85
105
125
185
240
355
450
630
870
1085
1370
1685
2010
2645
3240
18
23
30
40
52
72
94
123
153
196
240
284
331
381
429
507
582
40
40
45
45
50
60
65
80
85
100
115
125
135
155
165
185
205
4125956
4125770
4125785
4125801
4125803
4125805
4126254
4126255
4126256
4126257
4126258
4126259
–
–
–
–
–
–
–
–
–
–
–
–
2x1,0
2x1,5
2x2,5
2x4
2x6
2x10
2x16 Flex
2x25 Flex
2x35 Flex
2x50 Flex
2x70 Flex
2x95 Flex
3,6
3,8
4,3
5,2
5,4
8,7
10,0
14,5
14,7
18,1
18,7
22,2
9,0
9,5
10,5
12,0
13,0
15,5
18,0
23,0
24,5
28,5
33,0
36,5
105
125
155
205
305
465
610
955
1185
1605
2165
2745
15
20
26
34
44
61
80
105
130
167
204
241
55
60
65
75
80
95
110
140
150
175
200
220
4125957
4125772
4125786
4125802
4125804
4125806
4126271
4126273
4126275
4126277
4126279
4126281
4126283
4126285
4126287
4126289
–
4125773
4125787
4125880
4125882
4125884
4126272
4126274
4126276
4126278
4126280
4126282
4126284
4126286
4126288
4126290
3x1,0
3x1,5
3x2,5
3x4
3x6
3x10
3x16 Flex
3x25 Flex
3x35 Flex
3x50 Flex
3x70 Flex
3x95 Flex
3x120 Flex
3x150 Flex
3x185 Flex
3x240 Flex
3,7
4,1
5,2
5,3
5,8
9,3
10,7
14,6
15,0
18,3
22,0
22,8
37,8
39,3
47,9
50,7
9,5
10,0
11,0
12,5
14,0
16,5
19,0
24,5
26,0
30,5
35,5
39,0
44,0
50,0
55,0
62,0
125
150
190
255
360
555
735
1140
1455
2015
2755
3495
4515
5620
6875
9005
13
16
21
28
36
50
66
86
107
137
168
199
232
267
300
355
60
65
70
80
85
100
115
150
160
185
215
235
265
305
335
375
G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Table continues on next page
5/2016
–
4128426
4127050
4127052
4127054
4127056
4127059
4127061
4127063
4127065
4127067
4127069
4127071
4127073
4127075
4127077
4127079
0,6/1kV
4125955
4125736
4125738
4125740
4125742
4125744
4126237
4126238
4126239
4126240
4126241
4126242
4126243
4126244
4126245
4126246
4126247
LKSM-SHF2 120°C
LKSM-SHF2 120°C
0,6/1kV
Part number
Normal
G-type
5/2016
LKSM-SHF2 120°C
0,6/1kV
82
LKSM-SHF2 120°C
0,6/1kV
Part number
Normal
G-type
Number of
conductors &
cross-section
n x mm2
Crosssection of
armour
mm2
Nominal
outer
diameter
mm
Approximate
weight kg/km
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
4125958
4125774
4125788
4125830
4125832
4125834
4126301
4126303
4126305
4126307
4126309
4126311
4126313
4126315
–
4125775
4125789
4125831
4125833
4125835
4126302
4126304
4126306
4126308
4126310
4126312
4126314
4126316
4x1,0
4x1,5
4x2,5
4x4
4x6
4x10
4x16 Flex
4x25 Flex
4x35 Flex
4x50 Flex
4x70 Flex
4x95 Flex
4x120 Flex
4x150 Flex
4,1
4,5
5,3
5,7
8,8
10,3
11,9
14,8
18,1
19,5
22,6
37,8
39,3
48,2
10,0
11,0
12,5
13,5
15,5
18,0
21,5
27,0
29,0
34,0
39,0
44,0
49,0
55,5
145
175
235
310
465
680
930
1415
1850
2540
3490
4625
5750
7265
13
16
21
28
36
50
66
86
107
137
168
199
232
267
65
70
75
85
95
110
130
165
175
205
235
265
295
335
4125959
4125776
4125790
4126011
4126013
4126015
4126331
4126333
–
4125777
4125791
4126012
4126014
4126016
4126332
4126334
5x1,0
5x1,5
5x2,5
5x4
5x6
5x10
5x16 Flex
5x25 Flex
4,5
5,0
5,6
8,6
9,7
11,5
13,2
18,1
10,5
12,0
13,5
15,0
17,0
20,0
23,0
29,5
170
215
280
400
550
815
1055
1635
10
13
17
23
30
42
55
71
65
75
80
95
105
120
140
180
4125960
4125961
4125962
4125963
4125964
4125965
4125977
4125978
4125981
–
–
–
–
–
–
–
–
–
7x1,0
10x1,0
12x1,0
14x1,0
16x1,0
19x1,0
24x1,0
27x1,0
37x1,0
4,9
8,7
9,0
9,4
10,0
10,6
12,5
12,8
14,4
11,5
15,0
15,0
16,0
17,0
17,5
20,5
21,0
23,5
210
310
340
375
435
480
595
645
825
9
8
8
7
7
7
6
6
5
75
90
95
100
105
110
125
130
145
4125778
4126025
4125780
4126027
4126030
4125782
4125828
4125783
4125784
4125779
4126026
4125846
4126028
4126029
4125781
4125829
4125847
4125848
7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
37x1,5
5,4
9,6
10,0
10,5
11,1
11,7
13,9
14,1
16,0
13,0
16,5
17,0
18,0
19,0
19,5
23,5
24,0
26,5
260
385
430
490
535
600
765
830
1065
12
11
10
10
9
9
8
8
7
80
100
105
110
115
120
140
145
160
4125792
4126033
4125794
4126035
4126037
4125796
4125798
4125768
4125793
4126034
4125795
4126036
4126038
4125797
4125799
4125769
7x2,5
12x2,5
10x2,5
14x2,5
16x2,5
19x2,5
24x2,5
27x2,5
8,5
10,8
11,5
11,8
12,5
13,2
15,7
16,1
15,0
18,5
19,0
20,5
21,5
22,5
26,0
27,0
375
525
580
670
745
840
1065
1160
16
14
13
13
12
11
10
10
90
115
115
125
130
135
160
165
Other sizes on request.
G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G16
83
LKSM-SHF2 120°C
0,6/1kV
5/2016
LKSM-SHF2 120°C
250V
84
LKSM-SHF2 120°C, 250V
Heat and oil resistant armoured control and instrumentation cable
DESIGN:
STANDARDS:
IEC 60092-376, design
5/2016
1. Conductor
- stranded copper conductor IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- improved heat resistant XLPE (+120°C) IEC 60092-360
3. Bedding
- filler tape
4. Armour
- copper wire braid, coverage > 90%
IEC 60092-350
- tinned copper wire braid on request
5. Sheath
- improved heat resistant SHF2 (+120°C) IEC 60092-360
- standard colour black with grey stripes, other colours on request
+120°C heat
resistant
Oil resistant
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Application: For fixed installation in most areas and on open deck in ships or on oil rigs and
various industrial use. Excellent resistance against weathering, ozone, UV-rays, Oil / Diesel oil.
Typical Marine, Oil, Gas and Petrochemical applications are for example Ship Engine rooms,
power plants and/or other areas where ambient temperature may exceed +80°C, which is the
limit for traditional IEC 60092-cables.
Rated voltage
150/250V (300V)
Oil resistance
IEC 60811-404 conditions according to 60092-360
Halogen-free
IEC 60754 series
Flame-retardant
IEC 60332-1-2 Test for single insulated wire and cable
IEC 60332-3-22 Test for bunched wires and cables, category A
Smoke emission
IEC 61034 series
Temperature rating:
Fixed installation:
-40ºC to +120ºC
Occasionally moved:
-20ºC to +120ºC
Max. conductor temperature: +120ºC
Core identification:
See technical information section
Sheath marking: Lot number, cable type, cable size, voltage, temperature, standards,
manufacturer's name, production month and meter marking printed on the sheath
The cable is marine type approved by all major classification societies. Cable name on type approval
certificate is LKSM-SHF2 250V.
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
85
Nominal
outer
diameter
mm
6,5
7,0
7,5
8,0
8,5
10,5
10,5
11,0
11,5
12,5
13,0
14,0
14,5
15,0
16,0
7,5
7,5
8,0
9,5
10,0
12,0
12,5
13,0
13,5
14,5
18,0
17,0
17,5
18,0
19,5
Approximate
weight kg/km
70
80
85
95
110
155
170
190
210
235
250
285
305
370
415
80
95
105
130
155
210
230
255
280
315
430
415
450
510
570
Current
Rating A
at +45°C
Min. bending
radius fixed
installation
mm
8,7
7,6
6,9
6,4
5,8
5,1
4,8
4,6
4,4
4,1
4,1
3,8
3,7
3,5
3,3
11,3
9,8
8,9
8,3
7,4
6,6
6,2
5,9
5,6
5,3
5,2
4,9
4,7
4,5
4,3
40
40
45
45
50
60
65
65
70
75
80
85
85
90
95
45
45
50
55
60
75
75
80
80
85
105
100
105
110
115
5/2016
2x0,5
3x0,5
4x0,5
5x0,5
7x0,5
10x0,5
12x0,5
14x0,5
16x0,5
19x0,5
20x0,5
24x0,5
27x0,5
32x0,5
37x0,5
2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
10x0,75
12x0,75
14x0,75
16x0,75
19x0,75
20x0,75
24x0,75
27x0,75
32x0,75
37x0,75
Crosssection of
armour
mm2
3,0
3,0
2,6
3,1
3,2
4,1
4,3
4,5
5,3
5,1
5,5
6,1
6,3
8,9
9,7
3,1
3,1
3,2
3,6
3,9
5,1
5,3
5,6
5,9
6,3
10,9
10,2
10,5
10,9
11,8
250V
Other sizes on request.
Number of
conductors &
cross-section
n x mm2
LKSM-SHF2 120°C
LKSM-SHF2 120°C
250V
Part number
Normal
4127779
4127780
4127781
4127782
4127783
4127784
4127785
4127786
4127787
4127788
4127789
4127790
4127791
4127792
4127793
4126402
4126403
4126404
4126405
4126407
4126410
4126412
4126414
4126416
4126419
4126420
4126424
4126427
4126432
4126437
5/2016
RFE-SHF2 120°C
250V
86
RFE-SHF2 120°C
Heat and oil resistant armoured pair instrumentation and communication cable
DESIGN:
STANDARDS:
IEC 60092-376, design
1. Conductor
- stranded copper conductor IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- improved heat resistant XLPE (+120°C) IEC 60092-360
3. Twisted pair
- two insulated cores twisted together to form a pair
See next page for Quad
4. Bedding
- filler tape
5. Armour
- copper wire braid, coverage > 90%
IEC 60092-350
- tinned copper wire braid on request
- the armour serves as a collective screen
6. Sheath
- improved heat resistant SHF2 (+120°C) IEC 60092-360
- standard colour black with grey stripes, other colours on request
+120°C heat
resistant
Oil resistant
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Application: For fixed installation in most areas and on open deck in ships or on oil rigs and
various industrial use. Excellent resistance against weathering, ozone, UV-rays, Oil / Diesel oil.
Typical Marine, Oil, Gas and Petrochemical applications are for example Ship Engine rooms,
power plants and/or other areas where ambient temperature may exceed +80°C, which is the
limit for traditional IEC 60092-cables.
Rated voltage
150/250V (300V)
Oil resistance
IEC 60811-404 conditions according to 60092-360
Halogen-free
IEC 60754 series
Flame-retardant
IEC 60332-1-2 Test for single insulated wire and cable
IEC 60332-3-22 Test for bunched wires and cables, category A
Smoke emission
IEC 61034 series
Temperature rating:
Fixed installation:
-40ºC to +120ºC
Occasionally moved:
-20ºC to +120ºC
Max. conductor temperature: +120ºC
Electrical data:
Loop resistance of pair, max. / +20°C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20°C
0,5mm2 0,75mm2
80
52
55
50
0,6
0,6
≥1500
≥1500
1,5mm2
24,4
60
0,7
≥1500
Unit
ohm/km
nF/km
mH/km
Mohm/km
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
87
Approximate
weight kg/km
Min. bending
radius fixed
installation
mm
1x2x0,5
1x4x0,5
2x2x0,5
4x2x0,5
7x2x0,5
8x2x0,5
10x2x0,5
12x2x0,5
14x2x0,5
16x2x0,5
19x2x0,5
24x2x0,5
1x2x0,75
1x4x0,75
2x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
16x2x0,75
19x2x0,75
24x2x0,75
32x2x0,75
1x2x1,5
1x4x1,5
2x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
19x2x1,5
24x2x1,5
32x2x1,5
6,5
7,5
9,5
10,5
12,5
13,5
15,5
16,0
17,0
18,0
19,0
21,5
7,5
8,5
11,0
12,5
15,0
16,0
18,0
19,0
20,0
21,5
23,0
25,5
29,0
10,0
10,5
14,5
17,0
20,0
21,5
24,5
26,0
27,5
31,5
35,0
40,0
80
95
115
150
215
235
310
340
395
425
480
585
90
120
145
200
315
345
415
465
535
585
675
815
1040
135
185
230
370
540
620
750
850
955
1230
1525
1945
40
45
55
65
75
80
90
95
100
110
115
130
45
50
65
75
90
95
110
115
120
130
140
155
175
60
65
85
100
120
130
150
155
165
190
210
240
Other sizes on request.
Core identification: See technical information section
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
(Quad)cable is built up as a star quad
with the following identification
1 core
2 core
3 core
4 core
white
blue
white
blue
Sheath marking: Lot number, cable type, cable size, voltage, temperature, standards,
manufacturer's name, production month and meter marking printed on the sheath
The cable is marine type approved by all major classification societies. Cable name on type approval
certificate is RFE-SHF2.
5/2016
4120362
4120364
4120363
4120366
4120368
4120369
4120370
4120371
4120372
4120373
4120374
4120376
4120382
4120384
4120383
4120386
4120388
4120389
4120390
4120391
4120392
4120393
4120394
4120396
4120398
4120490
4120491
4120492
4120493
4120494
4120495
4120496
4120497
4120498
4120499
4120500
4120501
Nominal
outer
diameter
mm
250V
Part number
Number of
conductors &
cross-section
n x mm2
RFE-SHF2 120°C
RFE-SHF2 120°C
250V
RFE-SHF2 (i) 120°C
250V
88
RFE-SHF2 (i) 120°C
Armoured and individually screened instrumentation and
communication cable 250V
5/2016
DESIGN:
STANDARDS:
IEC 60092-376, design
1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- improved heat resistant XLPE (+120°C) IEC 60092-360
3. Twisted pair & individual screen
- two insulated cores twisted together to form a pair
- plastic coated aluminium tape and a tinned copper drain wire
4. Bedding
- filler tape
5. Armour
- copper wire braid, coverage > 90%
IEC 60092-350
- tinned copper wire braid on request
6. Sheath
- improved heat resistant SHF2 (+120°C) IEC 60092-360
- standard colour black with grey stripes, other colours on request
+120°C heat
resistant
Oil resistant
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Application: For fixed installation in most areas and on open deck in ships or on oil rigs and
various industrial use. Excellent resistance against weathering, ozone, UV-rays, Oil / Diesel oil.
Typical Marine, Oil, Gas and Petrochemical applications are for example Ship Engine rooms,
power plants and/or other areas where ambient temperature may exceed +80°C, which is the
limit for traditional IEC 60092-cables.
Rated voltage
150/250V (300V)
Oil resistance
IEC 60811-404 conditions according to 60092-360
Halogen-free
IEC 60754 series
Flame-retardant
IEC 60332-1-2 Test for single insulated wire and cable
IEC 60332-3-22 Test for bunched wires and cables, category A
Smoke emission
IEC 61034 series
Temperature rating:
Fixed installation:
-40ºC to +120ºC
Occasionally moved:
-20ºC to +120ºC
Max. conductor temperature: +120ºC
Electrical data:
Loop resistance of pair, max. / +20°C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20°C
0,5mm2 0,75mm2
80
52
55
70
0,6
0,6
≥1500
≥1500
1,5mm2
24,4
90
0,7
≥1500
Unit
ohm/km
nF/km
mH/km
Mohm/km
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
89
Approximate
weight kg/km
Min. bending
radius fixed
installation
mm
1x2x0,5
1x4x0,5
2x2x0,5
3x2x0,5
4x2x0,5
7x2x0,5
8x2x0,5
10x2x0,5
12x2x0,5
14x2x0,5
16x2x0,5
19x2x0,5
24x2x0,5
27x2x0,5
30x2x0,5
32x2x0,5
37x2x0,5
1x2x0,75
1x4x0,75
2x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
19x2x0,75
24x2x0,75
1x2x1,5
1x4x1,5
2x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
19x2x1,5
24x2x1,5
32x2x1,5
7,0
7,5
9,5
10,0
11,0
13,0
13,5
15,5
16,5
17,5
18,5
19,5
22,0
23,0
24,0
24,5
26,5
7,5
8,5
11,0
13,0
15,5
16,5
18,5
19,5
21,0
23,5
26,0
10,0
11,0
14,5
17,0
20,5
22,0
25,0
26,0
28,0
32,0
36,0
41,0
85
110
135
165
195
285
345
420
485
535
590
690
840
925
1005
1070
1205
90
135
160
225
355
400
495
555
620
790
985
145
170
200
250
405
605
690
840
955
1090
1425
1755
40
45
60
60
65
75
80
95
100
105
110
120
135
140
145
150
160
45
50
65
75
95
100
110
115
125
140
155
60
65
85
105
120
130
150
155
170
195
215
245
Other sizes on request.
Core identification: See technical information section
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....)
Sheath marking: Lot number, cable type, cable size, voltage, temperature, standards,
manufacturer's name, production month and meter marking printed on the sheath
The cable is marine type approved by all major classification societies.
Cable name on type approval certificate is RFE-SHF2(i).
5/2016
4122338
4122342
4122344
4122346
4122348
4122350
4122352
4122354
4122356
4122358
4122360
4122362
4122364
4122366
4122368
4122370
4122372
4122006
4122008
4122010
4122012
4122014
4122016
4122018
4122020
4122022
4122024
4122026
4122050
4122049
4122052
4122054
4122056
4122058
4122060
4122062
4122064
4122066
4122068
4122070
Nominal
outer
diameter
mm
250V
Part number
Number of
conductors &
cross-section
n x mm2
RFE-SHF2 (i) 120°C
RFE-SHF2(i) 120°C
250V
OPTICAL FIBRE CABLE
90
FXMSU
Optical fibre
indoor/outdoor cable
Cable construction:
1. Central element glass fibre, 1,5 mm
2. PP-slotted core, 6,0 mm
3. Optical fibres, 250 μm
4. Swellable tape
5. Rip cord
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)
5/2016
6. UV-protected and halogen free sheath
- non-metallic
- networks in marine applications
- Fibres: 250 μm SM or MM fibres
- 4 - 48 fibres
Cable characteristics:
Maximum pulling force
Crush strength / 100 mm (plate)
Crush strength / 25 mm (mandrel)
Impact strength
Sheath marking
Minimum installation temperature
Operating temperature range
Longitudinal water tightness
Flame-retardant
Halogen-free
Smoke emission
500 N EN 187000 method 501
4000 N EN 187000 method 504
650 N EN 187000 method 504
25
J EN 187000 method 505
Cable type, manufacturer's name,
manufacturing number and time,
length marking in meter
-15 °C
-45...+70 °C
EN 187000 method 605B
.. Slotted core
cables have
blue and red
marker threads
for the first and
last slot
respectively.
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
IEC 60754 series
IEC 61034 series
For details see general information section
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
91
Part
number
FXMSU 1X4SML (L)
FXMSU 1X6SML (L)
FXMSU 2X6SML (L)
FXMSU 4X6SML (L)
FXMSU 1X4OM3L (L)
FXMSU 2X4OM3L (L)
FXMSU 3X4OM3L (L)
FXMSU 4X6OM3L (L)
FXMSU 1X4GKL (L)
FXMSU 1X6GKL (L)
FXMSU 2X4GKL (L)
FXMSU 3X4GKL (L)
FXMSU 4X4GKL (L)
FXMSU 4X6GKL (L)
FXMSU1X4SML+1X4GKL (L)
FXMSU1X4SML+2X4GKL (L)
FXMSU2X4SML+2X4GKL (L)
FXMSU1X6SML+3X4GKL (L)
FXMSU2X6SML+3X4GKL (L)
FXMSU1X4SML+1X4OM3 (L)
FXMSU1X4SML+2X4OM3L (L)
FXMSU2X4SML+2X4OM3L (L)
FXMSU1X6SML+3X4OM3L (L)
FXMSU2X6SML+3X4OM3L (L)
Other fiber combinations on request
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Diameter
of slotted
core,
mm
6
Nominal Approximate Minimum bending radius
outer
weight,
during
final
diameter,
kg/km
installation, installation,
mm
mm
mm
9,4
75
140
100
5/2016
10001
10022
10024
10028
14384
14386
14388
14398
14404
14406
14408
14410
14412
14416
14420
14422
14424
14426
14428
14449
14450
14451
14454
14455
Cable and number of
fibres
OPTICAL FIBRE CABLE
FXMSU
OPTICAL FIBRE CABLE
92
FXMMS
Optical fibre
installation cable
Cable construction:
Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
1. FRP central element 2 mm
2. PP-slotted core
3. Installation cable unit FMS 1 (2 mm)
4. Fire barrier tape
5. Rip cord
(only SHF2)
5/2016
6. Halogen free sheath 1,5 mm
- For tray installation
- Fibres: 2–8 SM or MM fibres, 900 μm
- Connectors can be mounted directly to the fibres
Cable characteristics:
Maximum pulling force
Crush strength / 100 mm (plate)
Crush strength / 25 mm (mandrel)
Impact strength, R = 300 mm
Sheath marking
Minimum bending radius
Nominal cable diameter
Cable weight
Minimum installation temperature
Operating temperature range
1500 N EN 187000 method 501
4000 N EN 187000 method 504
750 N EN 187000 method 504
30 J EN 187000 method 505
Cable type, manufacturer's name,
manufacturing number and time,
length marking in meter
195 mm during installation, 130 mm in final bending
13.1 mm
142 kg/km
-15 °C
-45...+70 °C
Flame-retardant
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables
category A
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
For details see general information section
Cable and number of
fibres
FXMMS 2-4
Diameter
of slotted
core,
mm
7,5
FXMMS 6-8
9,7
Nominal Approximate Minimum bending radius
outer
weight,
during
final
diameter,
kg/km
installation, installation,
mm
mm
mm
10,7
102
160
110
13,1
142
195
130
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
93
Part
number
10810
10812
10814
10816
13747
13748
13749
13750
13872
13874
13876
13878
Cable and number of
fibres
FXMMS 2SMT (2MM)
FXMMS 4SMT (2MM)
FXMMS 6SMT (2MM)
FXMMS 8SMT (2MM)
FXMMS 2GKT (2MM)
FXMMS 4GKT (2MM)
FXMMS 6GKT (2MM)
FXMMS 8GKT (2MM)
FXMMS 2OM3T (2MM)
FXMMS 4OM3T (2MM)
FXMMS 6OM3T (2MM)
FXMMS 8OM3T (2MM)
Nominal Approximate Minimum bending radius
outer
weight,
during
final
diameter,
kg/km
installation, installation,
mm
mm
mm
10,7
102
160
110
10,7
102
160
110
13,1
142
195
130
13,1
142
195
130
10,7
102
160
110
10,7
102
160
110
13,1
142
195
130
13,1
142
195
130
10,7
102
160
110
10,7
102
160
110
13,1
142
195
130
13,1
142
195
130
5/2016
Part number for oil resistant SHF2 cable:
4 + code from above table © 4xxxxx
Diameter
of slotted
core,
mm
7,5
7,5
9,7
9,7
7,5
7,5
9,7
9,7
7,5
7,5
9,7
9,7
OPTICAL FIBRE CABLE
FXMMS
OPTICAL FIBRE CABLE
94
Cabled optical fibres characteristics
Fibre coating:
L = 250 μm ± 10 μm
T = 900 μm ± 50 μm
Single mode fibre
10/125 μm
Fibre type
SML 250μm±10μm
SMT 900μm±50μm
5/2016
Mode field diameter (MFD)
Mode field eccentricity
-Installation cables
Cladding diameter
- Installation cables
Cladding ellipticity
Fibre attenuation
1310 nm
1310 nm
1550 nm
Zero dispersion range
Dispersion coefficient
- Dispersion at
Cut-off wavelength
- Installation cables
Polarization mode dispersion
Proof test
Fibre identification
Multi mode fibre
SM / OS2 (ITU-T G.652.D)
1550 nm
50/125 μm
9,3 +/- 0,5 μm
≤ 1,0 μm
≤ 0,5 μm
125 +/- 2 μm
125 +/- 1 μm
≤2%
≤ 0,40 dB/km
≤ 0,25 dB/km
1300...1324 nm
≤ 0,093 ps/nm2/km
≤ 18 ps/nm/km
≤ 1260 nm
1180...1250 nm
≤ 0,5 ps/√km
1 % / 1 sec
6 colour system
according to SFS 5648
OM3
Fibre type
OM3L 250μm±10μm
OM3T 900μm±50μm
Core diameter
Core ellipticity
Core eccentricity
Cladding diameter
Cladding ellipticity
Fibre attenuation
50 +/- 3 μm
≤6%
≤ 3 μm
125 +/- 2 μm
≤2%
≤ 2,7 dB/km
≤ 0,8 dB/km
≥ 1500 MHz x km (LED)
≥ 500 MHz x km (LED)
≥ 2000 MHz x km (Laser)
0,200 +/- 0,015
6 colour system
according to SFS 5648
Bandwidth
Numerical aperture, NA
Fibre identification
850 nm
1300 nm
850 nm
1300 nm
850 nm
Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com
Subject to change without prior notice. See latest updates on our webpage.
95
62,5/125 μm
GK / OM1
GKL 250μm±10μm
GKT 900μm±50μm
Core diameter
Core ellipticity
Core eccentricity
Cladding diameter
Cladding ellipticity
Fibre attenuation
62,5 +/- 3 μm
≤6%
≤ 3 μm
125 +/- 2 μm
≤2%
≤ 3,5 dB/km
≤ 1,0 dB/km
≥ 200 MHz x km
≥ 500 MHz x km
0,275 +/- 0,015
6 colour system
according to SFS 5648
Bandwidth
Numerical aperture, NA
Fibre identification
850 nm
1300 nm
850 nm
1300 nm
5/2016
Fibre type
OPTICAL FIBRE CABLE
Multi mode fibre
TECHNICAL INFORMATION
96
GENERAL INFORMATION
Standard for materials: IEC 60092-360
will replace and withdraw 60092-359
and 60092-351.
Halogen-free
Halogen-free refers to the absence
of halogens, such as chlorine and
fluorine, and is determined on
the basis of halogen content and
the acidity of gases of a cable.
Insulation material:
The designation SHF1 stands for thermoplastic compound. This material is
halogen-free, highly flame-retardant and
has low smoke emission.
The designation SHF2 stands for oil
resistant thermosetting compound. This
material is halogen-free, highly flameretardant and has low smoke emission.
4m
2.5 m
Sheathing material:
Test on
bunched
cables
IEC 60332-3
Burning is
allowed up
to max. 2.5
meters from
the burner
within
specified time.
3.5 m
The following designations are used for
insulation materials in this catalog.
All materials are halogen-free.
XLPE stands for cross-linked polyethylene compound. It has excellent
mechanical and electrical characteristics.
5/2016
All Helkama cables comply with the most
severe requirements of
category A.
1m
2m
IEC 60332-1 is the test for single insulated wire and cable. Test procedure and
requirements according to the picture
below.
50 mm
Definition of terms:
Oil resistance
Sheathing material is oil resistant
according to method IEC 60811-404 and
requirements from IEC 60092-360/SHF2.
The oil resistance is demonstrated by
immersion in IRM902 oil for 24h at
100°C.
Flame-retardant
To be flame-retardant, the cables
must withstand the test specified in
IEC standard 60332-3 or IEC 60332-1.
Flame-retardant cables do not propagate
fire, and are self-extinguishing.
475
mm
IEC 60754-1 determines the
halogen content of the material.
To meet the requirements as
halogen-free the halogen content
of the material may not exceed
0,5 % or 5 mg/g.
IEC 60754-2 determines the
degree of acidity of gases evolved
during combustion. The limit
values are 4,3 for pH and
10 mikroS for conductivity.
Smoke emission
Smoke emission refers to visibility
in a fire. The greater the light transmittance, the better the visibility.
When tested in accordance with
IEC 61034-1 (test method) and
IEC 61034-2 (test requirements)
the smoke emission of a cable during
fire must not exceed the following values.
550 600
mm mm
27m3 cube
smoke chamber
Min. 50 mm of the cable, measured from
the upper support, must remain unburned
after the specified time.
Requirements:
60 % light
transmittance
Un
IEC 60332-3 is the test for bunched wires
and cables and has three categories A,
B and C, defined by different limits for
flammable material and burning times.
Burning time describes how long the
burner is directed towards the bunch of
cables. The requirement for passing the
test is that after the burner has been
removed the cables must extinguish
themselves. Burning may not occur more
than 2.5 m from the burner as shown in
the figure.
Amount of
burning
material
Burning time
A
7 litres/m
40 min
B
3,5 litres/m 40 min
C
1,5 litres/m 20 min
Category
3A
Fire-resistant
IEC 60331-1 Test method for fire with
shock at a temperature of at least
830 °C for 90 minutes for cables of rated
voltage up to and including 0,6/1,0 kV
and with an overall diameter exceeding
20 mm.
IEC 60331-2 Test method for fire with
shock at a temperature of at least
830 °C for 90 minutes for cables of rated
voltage up to and including 0,6/1,0 kV
and with an overall diameter not
exceeding 20 mm.
830 °C / 90 min
gas burner
500 mm
110 mm
97
BENDING RADIUS
Recommended minimum bending
radius, ( R ) :
Outer
diameter (D)
During installation
Fixed installation
R = 9x D
R = 6x D
Tolerance
±0,5mm
±1,0mm
±1,5mm
< 25mm
> 25mm
< 25mm
> 25mm
RFE-HF
RFE-HF(i)
RFA-HF
RFA-HF(i)
RFE-FRHF
RFE-FRHF(i)
RFA-FRHF
RFA-FRHF(i)
LKSM-SHF2 120°C
LKSM-SHF2 120°C
RFE-SHF2 120°C
RFE-SHF2 (i) 120°C
Cable outer diameter, mm.
30,1 – 40
40,1 – 50
50,1 – 60
Tolerance
±2,0mm
±2,5mm
±3,0mm
(according to HD 308 S2)
250V
0,6/1kV
a
b
1
3
5
7
9
11
2
4
6
8
10
12
Normal type
1-core
BK
2-cores
BN BU
3-cores
BN BK
4-cores
etc.
5-cores
GY
Y/G BU
BN
BU BN
Y/G BN
GY BK
GY BK
1
3
Y/G
BU
GY
BN
BK
3
Y/G
4
6
5
4
250V
LKSM-HF
7-cores
and above
2-cores
1
G-type
(with earth
conductor)
2
2
2
7
6
1
5
Black numbers
on white base
2
1
3
4
5
Black numbers
on white base
Last core
yellow/green.
Black numbers on white base
BU = Blue, BN = Brown, BK = Black, GY = Grey, Y/G = Yellow/Green
3-cores
1
2
3
1,8/3kV
LKSM-VFD
1-core
BK
3-cores
BN BK
Black numbers on white base
4-cores
to 37-cores
GY
Black numbers on white base
3-cores
+ 3-ground
cores
Y/G
BN BK
Y/G
GY
Y/G
5/2016
Cable outer diameter, mm.
1 – 10
10,1 – 20
20,1 – 30
CORE IDENTIFICATION
Pair number
1
2
3
4
5
6
R = 6x D
R = 9x D
R = 4x D
R = 6x D
LKSM-HF
LKSM-EMC
RFE-EMC-FRHF
RFE-EMC-FRHF(i)
LKSM-VFD
LKMSM-HF
LKAM-HF
LKM-FRHF
LKMM-FRHF
LKSM-FRHF
LKMSM-FRHF
LKAM-FRHF
Radius (R)
DIAMETER TOLERANCE
During installation
During installation
Fixed installation
Fixed installation
TECHNICAL INFORMATION
LKM-HF
LKMM-HF
LKEM-HF
TECHNICAL INFORMATION
98
CURRENT RATING
"Current rating (A) at an ambient temperature of 45°C
according to the standard IEC 60092-352
0,6/1 kV +90°C marine cables."
Current carrying capacities in continous service at
maximum rated conductor temperature of +90°C.
For class 2 conductor cables
Size
N
1
2
3
4
5
7
10
12
14
16
19
24
27
37
1
18
23
30
40
52
72
96
127
157
196
242
293
339
389
444
522
601
0,85
15
20
26
34
44
61
82
108
133
167
206
249
288
331
377
444
511
0,7
13
16
21
28
36
50
67
89
110
137
169
205
237
272
311
365
421
0,7
13
16
21
28
36
50
67
89
110
137
169
205
237
272
311
365
421
0,58
10
13
17
23
30
42
56
74
91
0,52
9
12
16
0,46
8
11
14
0,44
8
10
13
0,41
7
9
12
0,40
7
9
12
0,37
7
9
11
0,35
6
8
11
0,33
6
7
10
0,30
5
7
9
1
2
3
4
5
7
10
12
14
16
19
24
27
37
1,5mm2
2,5mm2
4mm2
6mm2
10mm2
16mm2
25mm2
35mm2
50mm2
70mm2
95mm2
120mm2
150mm2
185mm2
240mm2
300mm2
1
17
22
30
39
50
71
94
123
153
196
240
284
331
381
429
507
582
0,85
14
19
26
33
43
60
80
105
130
167
204
241
281
324
365
431
495
0,7
12
15
21
27
35
50
66
86
107
137
168
199
232
267
300
355
407
0,7
12
15
21
27
35
50
66
86
107
137
168
199
232
267
300
355
407
0,58
10
13
17
23
29
41
55
71
89
0,52
9
11
16
0,46
8
10
14
0,44
7
10
13
0,41
7
9
12
0,40
7
9
12
0,37
6
8
11
0,35
6
8
11
0,33
6
7
10
0,30
5
7
9
Ambient temperature
Correction factor
+35°C
1,10
Factor, n
5/2016
For continuous service. Continuous service for a cable is
to be considered as a current-carrying service (with
constant load) having a duration longer than three times
the thermal time constant of the cable, i.e. longer than
the critical duration(see short time duty).
1,0mm2
1,5mm2
2,5mm2
4mm2
6mm2
10mm2
16mm2
25mm2
35mm2
50mm2
70mm2
95mm2
120mm2
150mm2
185mm2
240mm2
300mm2
For class 5 conductor cables
Size
N
Factor, n
1,0mm2
+40°C
1,05
+45°C
1,00
+50°C
0,94
+55°C
0,88
+60°C
0,82
+65°C
0,74
+70°C
0,64
+75°C
0,58
+80°C
0,47
99
SHORT CIRCUIT CURRENT
Based on formula:
Ik = 226
X
S
t
X
S
t
X
In
234 + Tk
234 + Tb
Formula 1:
Ik = 146
Ik
S
t
Tk
=
=
=
=
Maximum permissible short circuit current.
Cross-section of the conductor in mm2.
Duration of the short circuit in s.
Maximum rated conductor temperature,
short circuit, °C
Tb = Maximum rated conductor temperature,
normal, °C
Formula 1: For 0,6/1kV cable with XLPE or HF90 with
maximum operating temperature of +90°C (Tb) and
short circuit temperature of +250°C (Tk).
Cross-section of
the conductor
in mm2
1,0
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
0,2
0,3
0,5
0,8
1,3
2,0
3,3
5,2
8,2
11,4
16,3
22,9
31,0
39,2
49,0
60,4
78,4
97,9
0,5
1
2
3
0,2 0,1 0,1 0,1
0,3 0,2 0,2 0,1
0,5 0,4 0,3 0,2
0,8 0,6 0,4 0,3
1,2 0,9 0,6 0,5
2,1 1,5 1,0 0,8
3,3 2,3 1,7 1,3
5,2 3,7 2,6 2,1
7,2 5,1 3,6 3,0
10,3 7,3 5,2 4,2
14,5 10,2 7,2 5,9
19,6 13,9 9,8 8,0
24,8 17,5 12,4 10,1
31,0 21,9 15,5 12,6
38,2 27,0 19,1 15,6
49,6 35,0 24,8 20,2
61,9 43,8 31,0 25,3
Short circuit current in kA
10
0,0
0,1
0,1
0,2
0,3
0,5
0,7
1,2
1,6
2,3
3,2
4,4
5,5
6,9
8,5
11,1
13,9
5/2016
SHORT CIRCUIT FACTOR
Short Circuit Factor can be calculated by following formula:
SHORT CIRCUIT FACTOR =
Duration of the short circuit in s.
TECHNICAL INFORMATION
Maximum permissible short circuit current.
0,6/1 kV +90°C marine cables.
SHORT CIRCUIT CURRENT
CURRENT RATING
TECHNICAL INFORMATION
100
SHORT TIME DUTY
Short time duty according to the standard
IEC 60092-352 0,6/1 kV +90°C
marine cables.
If a cable is intended to supply motor
or equipment operating for periods of half an hour or
one hour, its current rating given in table “current
rating”, may be increased using the relevant
correction factors given by formula:
correction =
factor
1,12
1-exp(-ts/T)
( ts = service time, min. T = Time constant, min.)
T = 0,245 x d 1,35
5/2016
(d = Overall diameter of the cable, mm.)
Overall
diameter of
the cable,
mm.
Service
time, min.
1
2
3
4
5
6
7
8
9
10
20
30
40
50
60
Time
Critical
constant, duration,
min.
min.
30
60
T
3x T
1,058
1,058
1,058
1,058
1,058
1,058
1,058
1,059
1,059
1,061
1,126
1,255
1,403
1,554
1,705
1,058
1,058
1,058
1,058
1,058
1,058
1,058
1,058
1,058
1,058
1,066
1,105
1,173
1,254
1,341
0,245
0,625
1,08
1,59
2,15
2,75
3,39
4,06
4,76
5,48
14,0
24,2
35,6
48,2
61,6
0,735
1,87
3,24
4,78
6,46
8,26
10,2
12,2
14,3
16,5
41,9
72,5
107
145
185
Correction factor.
Intermittent service
Correction factor for intermittent service
according to the standard IEC 60092-352
The correction factor given hereby has been
roughly calculated for periods of 10 min,
of which 4 min are with a constant load and
6 min without load.
Intermittence period = 10min.
Intermittence ratio = 40%.
Fi=
1-exp(-10/T)
1-exp(-4/T)
Overall diameter of
the cable, mm.
Correction
factor.
1
2
3
4
5
6
7
8
9
10
20
30
40
50
60
1,000
1,001
1,012
1,042
1,083
1,127
1,170
1,208
1,242
1,273
1,433
1,490
1,518
1,534
1,544
101
VOLTAGE DROP
Size
1.0mm2
1.5mm2
2.5mm2
4mm2
6mm2
10mm2
16mm2
25mm2
35mm2
50mm2
70mm2
95mm2
120mm2
150mm2
185mm2
240mm2
300mm2
Resistance
at +20°C
ohm/km
Resistance
at +90°C
ohm/km
Voltage
reduction
mV/Am *)
Resistance
at +45°C
ohm/km
Current
rating
A **)
Voltage
reduction
mV/m ***)
18,1
12,1
7,41
4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,124
0,0991
0,0754
0,0601
23,1
15,4
9,45
5,88
3,93
2,33
1,47
0,927
0,668
0,493
0,342
0,246
0,195
0,158
0,1264
0,0961
0,0766
46,2
30,9
18,9
11,8
7,85
4,67
2,93
1,85
1,34
0,987
0,683
0,492
0,390
0,316
0,253
0,192
0,153
19,9
13,3
8,14
5,06
3,38
2,01
1,26
0,798
0,575
0,425
0,294
0,212
0,168
0,136
0,1088
0,0828
0,0660
18
23
30
40
52
72
96
127
157
196
242
293
339
389
444
522
601
0,72
0,61
0,49
0,41
0,35
0,29
0,24
0,20
0,18
0,17
0,14
0,12
0,11
0,11
0,097
0,086
0,079
Size
0,75mm2
1.0mm2
1.5mm2
2.5mm2
4mm2
6mm2
10mm2
16mm2
25mm2
35mm2
50mm2
70mm2
95mm2
120mm2
150mm2
185mm2
240mm2
300mm2
Resistance
at +20°C
ohm/km
Resistance
at +90°C
ohm/km
Voltage
reduction
mV/Am *)
Resistance
at +45°C
ohm/km
Current
rating
A **)
Voltage
reduction
mV/m ***)
26,0
19,5
13,3
7,98
4,95
3,30
1,91
1,21
0,78
0,554
0,386
0,272
0,206
0,161
0,129
0,106
0,0801
0,0641
33,2
24,9
17,0
10,18
6,31
4,21
2,44
1,54
0,995
0,706
0,492
0,347
0,263
0,205
0,164
0,135
0,102
0,082
66,3
49,7
33,9
20,4
12,6
8,42
4,87
3,09
1,99
1,41
0,984
0,694
0,525
0,411
0,329
0,270
0,204
0,163
28,6
21,4
14,6
8,76
5,44
3,62
2,10
1,33
0,857
0,608
0,424
0,299
0,226
0,177
0,142
0,116
0,088
0,070
14
17
22
30
39
50
71
94
123
153
196
240
284
331
381
429
507
582
0,80
0,73
0,64
0,53
0,42
0,36
0,30
0,25
0,21
0,19
0,17
0,14
0,13
0,12
0,11
0,10
0,09
0,08
Cable types: LKSM-HF 250V, RFE-HF, RFE-HF(i), RFA-HF, RFA-HF(i), RFE-FRHF, RFE-FRHF(i), RFA-FRHF, RFA-FRHF(i)
Size
0,5 mm2
0,75 mm2
1,5 mm2
Resistance
at +20°C
ohm/km
Maximum
conductor
temperature, °C
Resistance
at +45°C
ohm/km
Voltage
reduction
mV/Am at +45°C
Resistance
at +90°C
ohm/km
Voltage
reduction
mV/Am at +90°C
40,4
26,0
12,8
90
90
90
44,4
28,6
14,1
88,7
57,1
28,1
51,5
33,2
16,3
103,0
66,3
32,6
*) at +90°C
**) For continuous service (single core, ambient temperature +45°C)
***) at maximum current rating for continuous service at +45°C
5/2016
Cable types: LKM-HF FLEX, LKSM-HF FLEX, LKEM-HF (Cables with class 5 conductor)
TECHNICAL INFORMATION
Cable types: LKM-HF, LKSM-HF, LKAM-HF, LKM-FRHF, LKSM-FRHF (Cables with class 2 conductor)
HELKAMA BICA OY
Lakimiehenkatu 4
FI-20780 KAARINA
Finland
Tel. +358 2 410 8700
Fax +358 2 237 2428
firstname.lastname@helkamabica.fi
sales@helkamabica.fi
Helkama Bica
(Shanghai) Co., Ltd.
Plot 1-2, MinHang Export Processing Zone
No. 3111 Huan Cheng West Road
Fengxian District, Shanghai 201401,
China
Tel. +86 21 3365 5333,
Fax +86 21 3365 5331
sales@helkamabica.cn
www.helkamabica.com

Similar documents

ÖLfLEx® iNStrum SWA 280 h

ÖLfLEx® iNStrum SWA 280 h the international market and is a Lapp Group Company. Lapp Group is a global supplier of cable technology well present worldwide with 41 own sales companies, 17 production plants and more than 100 ...

More information

Marine Cables

Marine Cables LSM-FRHF 0,6/1 (1,2) kV Armoured Fire Resistant Power and Control Cable

More information

INDUSTRIAL CABLES OPTICAL FIBRE CABLES

INDUSTRIAL CABLES OPTICAL FIBRE CABLES applied as a screen over the polyester tape. 7x0,30 tinned copper drain wire under the screen.