marine and offshore cables
Transcription
marine and offshore cables
5/2016 MARINE AND OFFSHORE CABLES MARINE AND OFFSHORE CABLES • INDUSTRIAL CABLES • OPTICAL FIBRE CABLES • FLEXIBLE CABLES Contents Helkama – a true specialist in marine cables..3 Approvals ..........................................................3 0,6/1kV cables LKM-HF..............................................................4 LKMM-HF ..........................................................8 LKSM-HF..........................................................10 LKMSM-HF .....................................................14 LKAM-HF..........................................................16 LKEM-HF..........................................................18 EMC cables LKSM-EMC ......................................................20 LKSM-EMC-FRHF.............................................24 RFE-EMC..........................................................28 RFE-EMC(i) ......................................................30 RFE-EMC-FRHF NEW .......................................32 RFE-EMC-FRHF(i) NEW....................................34 1,8/3kV cables LKSM-VFD .......................................................36 0,6/1kV FR cables LKM-FRHF........................................................38 LKMM-FRHF NEW............................................42 LKSM-FRHF .....................................................44 LKMSM-FRHF NEW .........................................48 LKAM-FRHF .....................................................50 250V cables LKM-HF ...........................................................52 LKSM-HF..........................................................54 LKAM-HF .........................................................56 RFE-HF.............................................................58 RFE-HF (i) ........................................................60 RFA-HF.............................................................62 RFA-HF (i) ........................................................64 Marine cable factory in Kaarina, Finland. Marine cable factory in Shanghai, China. 250V FR cables LKM-FRHF .......................................................66 LKSM-FRHF ....................................................68 LKAM-FRHF ....................................................70 RFE-FRHF.........................................................72 RFE-FRHF (i) ....................................................74 RFA-FRHF ........................................................76 RFA-FRHF (i)....................................................78 Heat resistant cables 120°C LKSM-SHF2 120°C 0,6/1kV .............................80 LKSM-SHF2 120°C 250V .................................84 RFE-SHF2 120°C 250V.....................................86 RFE-SHF2 (i) 120°C 250V ................................88 Optical fibre cables FXMSU.............................................................90 FXMMS ............................................................92 Cabled optical fibres characteristics.................94 Technical information General information .........................................96 Bending radius .................................................97 Diameter tolerance ...........................................89 Core identification ............................................97 Current rating...................................................98 Short circuit current.........................................99 Short time duty ..............................................100 Voltage drop...................................................101 Subject to change without prior notice. See latest updates on our webpage www.helkamabica.com 3 Helkama is specializing in development and production of marine and offshore cables. Our experience in this field goes back more than fifty years. Our high technical quality has been achieved by continuous development work supported by our clients. In this catalogue we proudly present our most comprehensive range of marine cables. We have chosen to produce only halogen-free cables. They remarkably improve the fire safety of the ships by not emitting toxic burning fumes or thick smoke. In addition no corrosive gases damaging the ship and its equipment are emitted in case of a fire. Using the latest technology we have been able to reduce cable weight and size to a minimum and still maintain quality as well as enabling easy and fast installation. The halogen free range of cables includes both flame-retardant (IEC 60332-3) and fire resistant (IEC 60331-series) cables. Helkama marine cables are approved by all major classification societies. As a specialized and independent company, focusing on service, we have been able to grow steadily by quickly responding to our customers’ needs. Our short delivery times, backed up by extensive stocks, enable us to deliver punctually and keep our clients satisfied. This remains our goal for the future, too. Type Approval Certificates for factories in Finland and China Please check updated approval situation on www.helkamabica.com www.helkamabica.com HELKAMA — a true specialist in marine cables 0,6/1kV CABLES 4 LKM-HF Unarmoured power and control cable 0,6/1kV DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,0-10mm2 IEC 60228, class 2 - stranded copper conductor 16-300mm2 IEC 60228, class 5 (Flex) - tinned stranded copper conductor on request Flameretardant 2. Insulation Fire- XLPE plastic IEC 60092-360 resistant 5/2016 3. Bedding - separator tape 4. Sheath - polyolefine plastic, SHF1 IEC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour black, other colours on request Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units. Main characteristics Rated voltage AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 5 Part number Normal G-type 28395 28396 27000 27002 27004 27006 27009 27011 27013 27015 27017 27019 27021 27023 27025 27027 27029 – – – – – – – – – – – 28397 25672 25689 25704 25706 25708 26072 26074 26076 26078 26080 26082 26085 26086 26088 26090 1x1,0 1x1,5 1x2,5 1x4 1x6 1x10 1x16 Flex 1x25 Flex 1x35 Flex 1x50 Flex 1x70 Flex 1x95 Flex 1x120 Flex 1x150 Flex 1x185 Flex 1x240 Flex 1x300 Flex 2x1,0 2x1,5 2x2,5 2x4 2x6 2x10 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 2x70 Flex 3x1,0 3x1,5 3x2,5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 3x150 Flex 3x185 Flex 3x240 Flex Nominal outer diameter mm 5,0 5,5 5,5 6,5 7,0 8,0 9,0 11,5 12,0 14,0 16,5 18,0 20,0 23,0 25,0 28,0 31,5 7,5 8,5 9,5 10,5 12,0 14,0 16,5 20,5 22,5 26,5 30,5 8,0 9,0 10,0 11,5 13,0 15,0 17,5 22,0 24,0 28,5 33,0 37,0 41,5 47,5 52,5 59,5 Approximate weight kg/km 35 40 55 70 95 140 185 290 380 535 740 955 1205 1520 1845 2455 3030 65 80 115 155 240 360 495 760 1015 1410 1955 80 100 145 200 310 465 630 970 1310 1840 2575 3320 4220 5335 6545 8695 Current Rating A at +45°C 18 23 30 40 52 72 94 123 153 196 240 284 331 381 429 507 582 15 20 26 34 44 61 80 105 130 167 204 13 16 21 28 36 50 66 86 107 137 168 199 232 267 300 355 Min. bending radius fixed installation mm 20 25 25 30 30 35 40 50 50 60 70 75 85 95 155 170 190 30 35 40 45 50 60 70 85 95 160 185 35 40 45 50 55 65 75 90 100 175 200 225 250 285 320 360 G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Table continues on next page 5/2016 25580 25636 25638 25640 25642 25644 25647 25649 25651 25653 25655 25657 25659 25661 25663 25665 26047 25581 25670 25686 25702 25701 25717 26054 26055 26056 26057 26058 25582 25671 25688 25703 25705 25707 26071 26073 26075 26077 26079 26081 26083 26084 26087 26089 Number of conductors & cross-section n x mm2 0,6/1kV CABLES LKM-HF 0,6/1kV 5/2016 0,6/1kV CABLES 6 LKM-HF 0,6/1kV Part number Normal G-type 25583 25673 25690 25725 25727 25729 26101 26103 26105 26107 26109 26111 26113 26115 26117 25584 25676 25692 25864 25866 25868 26131 26133 26135 26137 26139 26145 25585 25586 25587 25588 25589 25590 25592 25593 25597 25595 28398 25674 25691 25726 25728 25730 26102 26104 26106 26108 26110 26112 26114 26116 26118 28399 25677 25693 25865 25867 25869 26132 26134 26136 26138 26140 26146 28400 28401 28402 28403 28404 28405 28407 28408 28409 28411 Number of conductors & cross-section n x mm2 4x1,0 4x1,5 4x2,5 4x4 4x6 4x10 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 4x95 Flex 4x120 Flex 4x150 Flex 4x185 Flex 5x1,0 5x1,5 5x2,5 5x4 5x6 5x10 5x16 Flex 5x25 Flex 5x35 Flex 5x50 Flex 5x70 Flex 5x95 Flex 7x1,0 10x1,0 12x1,0 14x1,0 16x1,0 19x1,0 24x1,0 27x1,0 30x1,0 37x1,0 Nominal outer diameter mm 8,5 10,0 11,0 12,5 14,0 16,5 19,5 25,0 27,0 32,0 37,0 41,5 46,5 53,0 59,0 9,5 11,0 12,0 13,5 15,5 18,5 21,5 27,5 30,0 35,0 41,0 46,0 10,5 13,5 13,5 14,5 15,5 16,0 19,0 19,5 20,0 22,0 Approximate weight kg/km 95 135 180 260 385 585 805 1255 1675 2365 3300 4305 5430 6895 8450 125 160 215 315 470 715 975 1545 2075 2920 4115 5360 155 220 250 280 325 365 465 510 555 680 Current Rating A at +45°C 13 16 21 28 36 50 66 86 107 137 168 199 232 267 300 10 13 17 23 30 42 55 71 89 114 139 165 9 8 8 7 7 7 6 6 5 5 Min. bending radius fixed installation mm 35 40 45 55 60 70 80 100 165 195 225 250 280 320 355 40 45 50 55 65 75 90 165 180 215 250 275 45 55 55 60 65 65 80 80 85 90 G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Table continues on next page 7 Part number Normal G-type Number of conductors & cross-section n x mm2 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 25679 25668 25681 25992 25990 25683 25876 25685 25687 7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 37x1,5 11,5 15,0 15,5 16,5 17,0 18,5 22,0 22,0 25,0 200 290 335 380 430 495 635 700 920 12 11 10 10 9 9 8 8 7 50 60 65 70 70 75 90 90 100 25694 25993 25696 25995 25997 25873 25877 26141 26143 25695 25994 25874 25996 25998 25872 25878 26142 26144 7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 37x2,5 13,5 17,0 17,5 18,5 19,5 20,5 24,5 25,0 28,5 285 410 465 535 605 690 900 990 1310 16 14 13 13 12 11 10 10 9 55 70 70 75 80 85 100 155 175 Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 25678 25667 25680 25991 25989 25682 25875 25684 25675 0,6/1kV CABLES LKM-HF 0,6/1kV 0,6/1kV CABLES 8 LKMM-HF Unarmoured power cable with extruded filler 0,6/1kV DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded copper conductor 16–150mm2 IEC 60228, class 5 - tinned stranded copper conductor on request 5/2016 2. Insulation - XLPE plastic IEC 60092-360 3. Bedding - extruded filler 4. Sheath - polyolefine plastic, SHF1 IEC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour black, other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units. Main characteristics Rated voltage AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 9 – – – – – – – – – – 27566 27570 27574 27578 27582 27587 27591 27595 27599 27603 27607 27611 27615 27619 27623 27630 27634 27638 27642 27646 27651 27655 27659 27663 27667 27694 27698 27702 27706 27710 27715 27719 2x1,5 2x2,5 2x4 2x6 2x10 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 2x70 Flex 3x1,5 3x2,5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 3x150 Flex 3x185 Flex 3x240 Flex 4x1,5 4x2,5 4x4 4x6 4x10 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 5x1,5 5x2,5 5x4 5x6 5x10 5x16 Flex 5x25 Flex Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 9,0 10,0 11,0 12,5 14,5 18,5 23,0 25,0 28,5 33,0 9,5 10,5 12,0 13,5 15,5 20,0 24,5 26,5 30,5 36,0 39,5 44,0 50,5 55,5 63,0 10,5 11,5 13,0 14,5 17,5 21,5 27,0 29,0 34,0 39,5 11,5 12,5 14,5 16,5 19,0 24,0 29,5 125 170 225 295 440 630 970 1305 1780 2435 140 190 260 360 530 770 1170 1570 2155 3020 3845 4840 6165 7510 9945 175 225 320 430 650 935 1440 1925 2660 3715 200 265 360 515 770 1150 1745 20 26 34 44 61 80 105 130 167 204 16 21 28 36 50 66 86 107 137 168 199 232 267 300 355 16 21 28 36 50 66 86 107 137 168 13 17 23 30 42 55 71 35 40 45 50 60 75 90 100 170 200 35 45 45 55 60 80 100 160 185 215 235 265 305 335 380 40 45 50 60 70 85 160 175 205 235 45 50 55 65 75 95 175 Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 27532 27534 27536 27538 27540 27543 27545 27547 27549 27551 27564 27568 27572 27576 27580 27585 27589 27593 27597 27601 27605 27609 27613 27617 27621 27628 27632 27636 27640 27644 27649 27653 27657 27661 27665 27692 27696 27700 27704 27708 27713 27717 Nominal outer diameter mm 5/2009 Part number Normal G-type Number of conductors & cross-section n x mm2 0,6/1kV CABLES LKMM-HF 0,6/1kV 0,6/1kV CABLES 10 LKSM-HF Armoured power and control cable 0,6/1kV 5/2016 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,0-10mm2 IEC 60228, class 2 - stranded copper conductor 16-300mm2 IEC 60228, class 5 (Flex) - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Bedding - filler tape 4. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request 5. Sheath - polyolefine plastic, SHF1 IEC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour black, other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units. Main characteristics Rated voltage AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 11 Part number Normal G-type Number of conductors & cross-section n x mm2 Crosssection of armour mm2 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 28425 28426 27050 27052 27054 27056 27058 27060 27062 27064 27066 27068 27070 27072 27074 27076 27078 1x1,0 1x1,5 1x2,5 1x4 1x6 1x10 1x16 Flex 1x25 Flex 1x35 Flex 1x50 Flex 1x70 Flex 1x95 Flex 1x120 Flex 1x150 Flex 1x185 Flex 1x240 Flex 1x300 Flex 3,0 3,0 2,5 3,1 3,1 3,6 4,1 4,9 5,5 8,7 10,0 11,5 12,3 13,7 15,2 18,2 18,7 6,0 6,5 7,0 7,5 8,0 9,5 10,5 13,0 14,0 16,0 18,5 20,0 22,5 25,0 27,0 30,5 34,0 69 77 84 108 132 192 240 360 455 640 865 1095 1365 1690 2030 2670 3270 18 23 30 40 52 72 94 123 153 196 240 284 331 381 429 507 582 40 40 45 45 50 60 65 80 85 100 115 125 135 155 165 185 205 25956 25770 25785 25801 25803 25805 26254 26255 26256 26257 26258 26259 – – – – – – – – – – – – 2x1,0 2x1,5 2x2,5 2x4 2x6 2x10 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 2x70 Flex 2x95 Flex 3,6 3,8 4,3 5,2 5,4 8,7 10,0 12,3 14,0 16,3 18,7 21,2 9,0 9,5 10,5 12,0 13,0 15,5 18,0 23,0 24,5 28,5 33,0 36,5 112 131 160 214 320 481 630 965 1210 1635 2225 2805 15 20 26 34 44 61 80 105 130 167 204 241 55 60 65 75 80 95 110 140 150 175 200 220 25957 25772 25786 25802 25804 25806 26271 26273 26275 26277 26279 26281 26283 26285 26287 26295 – 25773 25787 25880 25882 25884 26272 26274 26276 26278 26280 26282 26284 26286 26288 26296 3x1,0 3x1,5 3x2,5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 3x150 Flex 3x185 Flex 3x240 Flex 3,7 4,1 5,2 5,3 5,8 9,3 10,7 13,2 15,0 17,5 20,2 22,8 35,1 39,3 43,4 50,7 9,5 10,0 11,0 12,5 14,0 16,5 19,0 24,5 26,0 30,5 35,5 39,0 44,0 50,0 55,0 62,0 129 155 200 264 376 574 755 1155 1485 2050 2790 3555 4570 5720 6955 9150 13 16 21 28 36 50 66 86 107 137 168 199 232 267 300 355 60 65 70 80 85 100 115 150 160 185 215 235 265 305 335 375 G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Table continues on next page 5/2016 25955 25736 25738 25740 25742 25744 26237 26238 26239 26240 26241 26242 26243 26244 26245 26246 26247 0,6/1kV CABLES LKSM-HF 0,6/1kV 5/2016 0,6/1kV CABLES 12 LKSM-HF 0,6/1kV Part number Normal G-type Number of conductors & cross-section n x mm2 Crosssection of armour mm2 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 25958 25774 25788 25830 25832 25834 26301 26303 26305 26307 26309 26311 26313 26315 26317 – 25775 25789 25831 25833 25835 26302 26304 26306 26308 26310 26312 26314 26316 26318 4x1,0 4x1,5 4x2,5 4x4 4x6 4x10 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 4x95 Flex 4x120 Flex 4x150 Flex 4x185 Flex 4,1 4,5 5,3 5,7 8,8 10,3 11,9 14,8 16,7 19,5 22,6 35,0 39,3 44,0 48,9 10,0 11,0 12,5 13,5 15,5 18,0 21,5 27,0 29,0 34,0 39,0 44,0 49,0 55,5 61,5 151 183 241 320 481 699 950 1440 1865 2580 3540 4665 5830 7330 8920 13 16 21 28 36 50 66 86 107 137 168 199 232 267 300 65 70 75 85 95 110 130 165 175 205 235 265 295 335 370 25959 25776 25790 26011 26013 26015 26331 26333 26335 26325 26327 26329 – 25777 25791 26012 26014 26016 26332 26334 26336 26326 26328 26330 5x1,0 5x1,5 5x2,5 5x4 5x6 5x10 5x16 Flex 5x25 Flex 5x35 Flex 5x50 Flex 5x70 Flex 5x95 Flex 4,5 5,0 5,6 8,6 9,7 11,5 13,2 16,3 18,6 22,4 34,4 39,3 10,5 12,0 13,5 15,0 17,0 20,0 23,0 29,5 32,0 37,0 43,5 48,5 175 221 284 413 571 839 1070 1640 2265 3120 4415 5695 10 13 17 23 30 42 55 71 89 114 139 165 65 75 80 95 105 120 140 180 195 225 265 295 25960 25961 25962 25963 25964 25965 25977 25978 25979 25981 – – – – – – – – – – 7x1,0 10x1,0 12x1,0 14x1,0 16x1,0 19x1,0 24x1,0 27x1,0 30x1,0 37x1,0 4,9 8,7 9,0 9,4 10,0 10,6 12,5 12,8 13,3 14,4 11,5 15,0 15,0 16,0 17,0 17,5 20,5 21,0 21,5 23,5 214 319 350 387 435 484 611 658 710 840 9 8 8 7 7 7 6 6 5 5 75 90 95 100 105 110 125 130 135 145 G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G16 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Table continues on next page 13 Part number Normal G-type Number of conductors & cross-section n x mm2 Crosssection of armour mm2 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 25779 26026 25846 26028 26029 25781 25829 25847 – 25848 7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 30x1,5 37x1,5 5,4 9,6 10,0 10,5 11,1 11,7 13,9 14,1 14,7 16,0 13,0 16,5 17,0 18,0 19,0 19,5 23,5 24,0 24,5 26,5 266 396 446 496 549 615 789 854 924 1097 12 11 10 10 9 9 8 8 7 7 80 100 105 110 115 120 140 145 150 160 25792 25794 26033 26035 26037 25796 25798 25768 26040 25849 25793 25795 26034 26036 26038 25797 25799 25769 – 25850 7x2,5 12x2,5 10x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 30x2,5 37x2,5 8,5 10,8 11,5 11,8 12,5 13,2 15,7 16,1 16,7 18,1 15,0 18,5 19,0 20,5 21,5 22,5 26,0 27,0 27,5 30,0 378 525 588 676 752 846 1070 1165 1265 1524 16 14 13 13 12 11 10 10 10 9 90 115 115 125 130 135 160 165 170 185 Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G16 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 25778 26025 25780 26027 26030 25782 25828 25783 26039 25784 0,6/1kV CABLES LKSM-HF 0,6/1kV 0,6/1kV CABLES 14 LKMSM-HF 5/2016 DESIGN: Armoured power cable with extruded filler 0,6/1kV STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded copper conductor 16–150mm2 IEC 60228, class 5 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Bedding - extruded filler 4. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid and galvanized steel wire braid on request 5. Sheath - polyolefine plastic, SHF1 IEC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour black, other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units. Main characteristics Rated voltage AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 15 Part number Normal G-type – – – – – – – – – 27266 27270 27274 27278 27282 27287 27291 27295 27299 27303 27307 27311 27315 27330 27334 27338 27342 27346 27351 27355 27359 27363 27367 27371 27375 27394 27398 27402 27406 27410 27415 27419 2x1,5 2x2,5 2x4 2x6 2x10 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 3x1,5 3x2,5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 3x150 Flex 4x1,5 4x2,5 4x4 4x6 4x10 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 4x95 Flex 4x120 Flex 5x1,5 5x2,5 5x4 5x6 5x10 5x16 Flex 5x25 Flex Crosssection of armour mm2 4,9 5,4 6,0 9,2 10,7 12,4 15,4 16,7 19,4 5,3 5,7 8,7 9,7 11,5 13,2 16,5 18,3 20,7 24,5 38,7 41,7 50,1 5,6 6,3 9,5 10,6 12,6 14,8 18,4 19,7 23,0 37,4 41,4 46,7 6,1 9,3 10,4 11,6 13,8 16,0 20,1 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 11,5 12,5 14,0 15,5 17,5 20,0 24,5 26,0 30,0 12,0 13,5 15,0 16,0 18,5 21,0 26,0 28,0 32,0 37,5 42,0 46,0 52,5 13,0 14,5 16,0 17,5 20,0 23,5 28,5 31,0 35,5 42,0 46,0 51,5 14,0 15,5 17,0 19,0 22,0 25,5 31,0 195 230 290 420 575 740 1085 1365 1825 220 275 365 490 685 885 1320 1685 2275 3135 4075 5015 6380 260 320 430 585 825 1090 1610 2075 2800 3985 5020 6320 295 390 510 685 980 1305 1920 20 26 34 44 61 80 105 130 167 16 21 28 36 50 66 86 107 137 168 199 232 267 16 21 28 36 50 66 86 107 137 168 199 232 13 17 23 30 42 55 71 70 75 85 90 105 120 145 155 180 75 80 90 95 110 125 155 165 195 225 250 275 315 80 85 95 105 120 140 170 185 210 250 275 310 85 95 105 115 130 150 185 Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 27232 27234 27236 27238 27240 27243 27245 27247 27249 27264 27268 27272 27276 27280 27285 27289 27293 27297 27301 27305 27309 27313 27328 27332 27336 27340 27344 27349 27353 27357 27361 27365 27369 27373 27392 27396 27400 27404 27408 27413 27417 Number of conductors & cross-section n x mm2 0,6/1kV CABLES LKMSM-HF 0,6/1kV 0,6/1kV CABLES 16 LKAM-HF Screened power and control cable 0,6/1kV DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 5/2016 2. Insulation - XLPE plastic IEC 60092-360 3. Screen - drain wire of tinned copper 1,0mm2 (in all sizes) - aluminium polyester tape, IEC 60092-350 coverage 100% 4. Sheath - polyolefine plastic, SHF1 IEC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour black, other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units, especially when lightweight cables are needed. Main characteristics Rated voltage AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 17 Part number Normal G-type – 27107 27111 27115 27119 27141 27123 27145 27149 27127 27131 27135 27156 27137 – 27109 27113 27117 27121 27143 27125 27147 27151 27129 27133 27139 27158 27153 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 2x1,5 3x1,5 4x1,5 5x1,5 7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 32x1,5 37x1,5 2x2,5 3x2,5 4x2,5 5x2,5 7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 32x2,5 37x2,5 9,0 9,5 10,0 11,0 12,0 15,5 16,0 16,5 17,5 18,5 22,0 22,5 23,5 25,0 9,5 10,5 11,0 12,5 13,5 17,5 18,0 18,5 19,5 21,0 25,0 25,5 26,5 28,5 100 125 145 175 220 310 350 395 450 510 650 715 825 935 125 160 195 240 300 435 495 560 630 740 935 1025 1195 1355 20 16 16 13 12 11 10 10 9 9 8 8 7 7 26 21 21 17 16 14 13 13 12 11 10 10 9 9 55 55 60 65 70 90 95 100 105 110 130 135 140 150 60 60 65 75 80 105 105 110 120 125 150 150 160 170 Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 27102 27106 27110 27114 27118 27140 27122 27144 27148 27126 27130 27134 27155 27136 27104 27108 27112 27116 27120 27142 27124 27146 27150 27128 27132 27138 27157 27152 Number of conductors & cross-section n x mm2 0,6/1kV CABLES LKAM-HF 0,6/1kV 0,6/1kV CABLES 18 LKEM-HF DESIGN: 5/2016 1. Conductor - stranded flexible copper conductor Switchboard wire 0,6/1kV STANDARDS: IEC 60092-353, design IEC 60228, class 5 2. Insulation - HF90 plastic IEC 60092-360 - standard colour black, other colours on request - on request, oil resistant thermosetting polyolefine, SHF2 Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed wiring in switchboards, control panels and other enclosures. Main characteristics Rated voltage AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series -test for single insulated wire and cable Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 19 Part number 25117* 25120 25121 25122 25124 25125 25126 25128 25130 25132 25134 25136 25138 25165 25166 25279 25281 25283 25285 * Rated voltage 300/500V Number of conductors & cross-section n x mm2 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 1x0,5 1x0,75 1x1,0 1x1,5 1x2,5 1x4 1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 2,3 2,7 2,8 3,1 3,6 4,1 4,7 5,7 6,7 8,6 9,7 11,9 13,7 16,2 18,2 20,8 23,3 26,8 28,9 10 14 17 21 32 45 63 103 153 241 330 472 665 879 1116 1411 1736 2336 2876 11 14 17 22 30 39 50 71 94 123 153 196 240 284 331 381 429 507 582 10 15 15 15 15 20 20 25 30 35 40 50 55 65 75 85 95 110 120 0,6/1kV CABLES LKEM-HF 0,6/1kV Other sizes on request. 5/2016 Available in colours: blue, dark blue, black, brown, red, yellow, green, yellow/green, grey, orange, violet and white Other colours on request Delivery lengths: 0,5 mm2, 0,75 mm2, 1 mm2, 1,5 mm2 and 2,5 mm2 available in 200 m boxes or 500 m drums 4 mm2 available in 100 m boxes or 500 m drums Part number for oil resistant SHF2 cable: 6 mm2 available in 100 m coils or 500 m drums 4 + code from above table © 4xxxxx EMC CABLES 20 LKSM-EMC Armoured power and control cable with improved EMC screening 0,6/1kV 5/2016 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor 2 -stranded copper conductor 1,0-10mm 2 IEC 60228, class 2 -stranded copper conductor 16-300mm IEC 60228, class 5 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Bedding - filler tape 4. Screen - copper tape, coverage 100% 5. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request 6. Sheath - polyolefine plastic, SHF1 IEC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour black, other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units. Design to meet requirements for improved EMC screening properties. Main characteristics Rated voltage AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Transfer impedance IEC 61196-1 (typical value 26dB over 1mΩ/m at 100MHz [20mΩ/m]) For details see general information section Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: See technical information section. Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 21 Part number Normal G-type Crosssection of armour mm2 Diameter of screen mm Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C 3,0 3,0 3,0 3,1 3,1 3,3 4,2 5,3 5,6 8,8 10,0 11,2 12,4 13,8 15,3 17,1 18,8 3,3 3,6 4,2 4,6 5,3 8,5 10,1 12,4 14,1 16,4 18,8 21,3 4,0 4,0 4,5 5,0 6,0 7,0 8,5 10,5 11,5 14,0 16,0 18,5 20,0 23,0 25,5 29,0 31,0 6,5 7,0 8,0 9,0 10,5 12,5 15,5 19,5 21,5 26,0 29,5 34,5 6,0 6,5 7,0 7,5 8,0 9,5 11,0 13,5 14,5 17,0 19,0 21,5 24,0 26,5 29,5 33,0 35,5 9,5 10,0 11,0 12,0 13,0 16,0 18,5 23,0 25,5 30,0 34,0 39,0 80 90 100 120 145 210 280 410 510 700 935 1180 1460 1800 2160 2785 3410 130 145 180 230 340 535 715 1045 1320 1785 2385 3100 18 23 30 40 52 72 94 123 153 196 240 284 331 381 429 507 582 15 20 26 34 44 61 80 105 130 167 204 241 1x1,0 1x1,5 1x2,5 1x4 1x6 1x10 1x16 Flex 1x25 Flex 1x35 Flex 1x50 Flex 1x70 Flex 1x95 Flex 1x120 Flex 1x150 Flex 1x185 Flex 1x240 Flex 1x300 Flex 2x1,0 2x1,5 2x2,5 2x4 2x6 2x10 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 2x70 Flex 2x95 Flex Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Min. bending radius fixed installation mm 35 40 40 45 50 55 65 80 85 100 115 130 145 160 175 195 215 55 60 65 70 80 95 110 140 155 180 205 235 Table continues on next page 5/2016 26904 27513 27514 27515 27516 27517 27518 27519 27520 27521 27522 27523 27524 27525 27526 27527 27528 26905 27480 27481 27482 27483 27484 27485 27486 27487 27529 27530 27531 Number of conductors & cross-section n x mm2 EMC CABLES LKSM-EMC 0,6/1kV EMC CABLES 22 LKSM-EMC 0,6/1kV 5/2016 Part number Normal G-type 26906 26861 26863 26865 26867 26869 26872 26874 26876 26878 26880 26882 26884 26886 26907 26942 26944 26946 26948 26950 26952 26954 26956 26958 26960 26962 26964 26966 26908 27488 27489 27490 27491 27492 27493 27494 26988 26862 26864 26866 26868 26870 26851 26852 26853 26854 26855 26856 26857 26858 26989 26943 26945 26947 26949 26951 26953 26955 26957 26959 26961 26963 26965 26967 26990 27838 27839 27940 27941 27942 27943 27944 Number of conductors & cross-section n x mm2 3x1,0 3x1,5 3x2,5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 3x150 Flex 4x1,0 4x1,5 4x2,5 4x4 4x6 4x10 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 4x95 Flex 4x120 Flex 4x150 Flex 5x1,0 5x1,5 5x2,5 5x4 5x6 5x10 5x16 Flex 5x25 Flex Crosssection of armour mm2 3,6 3,9 4,3 5,3 5,6 8,9 10,9 13,3 15,2 17,7 20,3 22,9 35,2 39,4 3,9 4,3 4,8 5,5 8,5 10,0 12,0 14,8 16,8 19,6 22,6 35,2 39,4 43,7 4,3 5,2 5,3 8,5 9,4 11,0 13,3 16,4 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Diameter of screen mm Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C 7,0 7,5 8,5 10,0 11,0 13,5 16,5 21,0 23,0 27,5 32,0 37,0 41,5 47,5 8,0 8,5 9,5 11,0 12,5 15,0 18,0 23,0 25,5 31,0 35,5 42,0 46,5 52,5 8,5 9,5 10,5 12,5 14,0 16,5 20,0 25,5 10,0 10,5 11,5 12,5 14,0 16,5 19,5 24,5 27,0 32,0 36,5 42,0 47,0 53,0 10,5 11,0 12,5 13,5 15,5 18,5 22,0 27,0 30,0 35,5 40,0 47,5 52,5 59,0 11,0 12,0 13,5 15,5 17,0 20,0 23,5 29,5 155 175 215 285 395 600 835 1235 1590 2200 2955 3825 4875 6060 175 200 260 340 505 755 1015 1505 1960 2715 3675 4910 6095 7605 200 245 300 430 595 900 1215 1815 13 16 21 28 36 50 66 86 107 137 168 199 232 267 13 16 21 28 36 50 66 86 107 137 168 199 232 267 10 13 17 23 30 42 55 71 Min. bending radius fixed installation mm 60 60 70 75 85 100 120 145 160 195 220 250 285 320 65 65 75 80 95 110 130 160 180 215 240 285 315 355 65 75 80 90 100 120 140 175 Table continues on next page 23 Part number Normal G-type 26991 26992 26993 26994 26995 26996 26997 26998 26999 27840 27842 27844 27846 27848 27850 27852 27854 27856 27841 27843 27845 27847 27849 27851 27853 27855 27857 7x1,0 10x1,0 12x1,0 14x1,0 16x1,0 19x1,0 24x1,0 27x1,0 37x1,0 7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 37x1,5 7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 37x2,5 CrossDiameter section of o f screen armour mm mm2 4,7 9,5 8,5 12,5 8,6 13,0 9,1 13,5 9,7 14,5 10,2 15,0 12,2 18,0 12,5 18,5 14,0 20,5 5,3 10,0 9,2 13,5 9,6 14,0 10,2 15,0 10,8 15,5 11,5 16,5 13,5 19,5 13,9 20,0 15,7 22,5 5,9 11,5 10,5 15,5 10,9 16,0 11,5 17,0 12,2 18,0 12,9 19,0 15,4 22,5 15,8 23,0 17,8 25,5 Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Nominal outer diameter mm Approximate weight kg/km 12,5 15,5 16,0 16,5 17,5 18,5 21,5 22,0 24,5 13,0 16,5 17,0 18,0 19,0 20,0 23,0 24,0 26,5 14,5 18,5 19,0 20,0 21,5 22,5 26,0 27,0 30,0 240 355 385 420 460 550 700 745 935 285 420 465 520 570 675 855 930 1175 365 550 615 690 775 910 1145 1250 1610 Current Rating A at +45°C 9 8 8 7 7 7 6 6 5 12 20 16 10 13 23 8 16 7 30 26 13 21 17 11 26 21 30 Min. bending radius fixed installation mm 75 95 95 100 105 110 130 130 145 80 100 100 110 115 120 140 145 160 85 110 115 120 130 135 155 160 180 5/2016 26909 26910 26911 26912 26913 26914 26915 26916 26917 27495 27497 27499 27501 27503 27505 27507 27509 27511 27496 27498 27500 27502 27504 27506 27508 27510 27512 Number of conductors & cross-section n x mm2 EMC CABLES LKSM-EMC 0,6/1kV EMC CABLES 24 LKSM-EMC-FRHF 5/2016 DESIGN: Fire-resistant armoured power and control cable with improved EMC screening 0,6/1kV STANDARDS: IEC 60092-353, design 1. Conductor 2 -stranded copper conductor 1,0-10mm 2 IEC 60228, class 2 Flame-stranded copper conductor 16-300mm IEC 60228, class 5 retardant - tinned stranded copper conductor on request Fire2. Insulation resistant - Mica tape Halogen- XLPE plastic IEC 60092-360 free 3. Bedding Low smoke - filler tape emission 4. Screen Oil resistant - copper tape, coverage 100% (only SHF2) 5. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request 6. Sheath - polyolefine plastic, SHF1, standard colour orange IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer shetah is recommended. Design to meet requirements for improved EMC screening properties. Main characteristics Rated voltage AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV) Maximum conductor temperature + 90 °C Flame-retardant Fire -resistant Halogen-free Smoke emission Oil resistance (only SHF2) IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60331-1 and IEC 60331-2 IEC 60754 series IEC 61034 series IEC 60811-404 conditions according to 60092-360/SHF2 Transfer impedance IEC 61196-1 (typical value 26dB over 1mΩ/m at 100MHz [20mΩ/m]) For details see general information section Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: See technical information section. Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 25 1x1,0 1x1,5 1x2,5 1x4 1x6 1x10 1x16 Flex 1x25 Flex 1x35 Flex 1x50 Flex 1x70 Flex 1x95 Flex 1x120 Flex 1x150 Flex 1x185 Flex 1x240 Flex 1x300 Flex – 27872 27873 27874 27875 27876 27877 27878 27879 27880 27881 – – – – – – – – – – – – – 2x1,0 2x1,5 2x2,5 2x4 2x6 2x10 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 2x70 Flex 2x95 Flex 3,7 4,1 4,5 5,1 5,6 8,9 11,4 12,6 14,8 16,6 19,0 21,5 7,5 8,0 9,0 10,0 11,0 13,5 15,5 19,5 22,0 26,0 30,0 35,0 10,0 10,5 11,5 13,0 14,0 16,5 19,0 23,5 25,5 30,0 34,5 39,5 140 160 190 245 365 540 730 1070 1350 1815 2420 3150 15 20 26 34 44 61 80 105 130 167 204 241 60 65 70 75 85 100 115 140 155 180 205 240 – 27882 27883 27884 27885 27886 27887 27888 27889 27890 27891 27892 27893 27894 – 28444 28445 28446 28447 28448 28449 28450 28451 28452 28453 28454 28455 28456 3x1,0 3x1,5 3x2,5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 3x150 Flex 4,0 4,3 4,8 5,5 11,3 9,6 11,5 14,7 15,8 18,5 22,2 32,5 36,1 40,2 8,0 8,5 9,5 10,5 12,5 14,5 17,5 21,5 24,0 28,5 32,5 38,5 42,5 48,0 10,5 11,0 12,5 13,5 15,5 17,5 20,5 25,5 28,0 33,0 37,5 43,5 48,0 54,0 170 190 240 305 485 630 890 1315 1675 2280 3055 4055 4980 6200 13 16 21 28 36 50 66 86 107 137 168 199 232 267 65 65 75 80 90 105 125 155 170 200 225 260 290 325 – 27897 27898 27899 27900 27905 27906 27907 27908 27909 27910 27912 27913 – – 28459 28460 28461 28462 28463 28464 28465 28466 28467 28468 28469 28470 – 4x1,0 4x1,5 4x2,5 4x4 4x6 4x10 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 4x95 Flex 4x120 Flex 4x150 Flex 4,4 4,8 5,4 11,3 9,2 10,7 12,8 15,6 18,3 20,4 23,3 36,1 40,2 44,8 9,0 9,5 10,5 12,0 13,5 16,0 19,0 24,0 26,5 32,0 36,5 43,0 47,5 53,5 11,5 12,5 13,5 15,0 16,5 19,5 23,0 28,0 31,0 36,5 41,5 48,5 53,5 60,5 195 230 280 420 540 760 1085 1585 2080 2810 3820 5025 6245 7770 13 16 21 28 36 50 66 86 107 137 168 199 232 267 70 75 80 90 100 115 135 165 185 220 250 290 320 360 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Diameter of screen mm Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 4,5 4,5 5,0 5,5 6,0 7,0 8,5 10,5 11,5 13,5 15,5 18,0 20,0 22,5 25,5 28,5 31,0 6,5 7,0 7,5 8,0 8,5 10,0 11,0 13,0 14,0 17,0 18,5 21,5 23,5 26,5 29,0 32,5 35,5 90 100 110 130 155 215 285 410 515 705 935 1190 1465 1800 2165 2790 3420 18 23 30 40 52 72 94 123 153 196 240 284 331 381 429 507 582 40 40 45 45 50 60 65 80 85 100 110 130 140 160 175 195 210 Table continues on next page 5/2016 – – – – – – – – – – – – – – – – – Part number Number of conductors & cross-section n x mm2 EMC CABLES – – – – – – – – – – – – – – – – – Crosssection of armour mm2 3,0 3,0 3,1 3,1 3,1 3,5 4,1 4,8 5,5 8,6 10,0 11,5 12,3 14,7 15,2 16,9 18,6 LKSM-EMC-FRHF 0,6/1kV EMC CABLES 26 LKSM-EMC-FRHF 0,6/1kV 5/2016 Part number Number of conductors & cross-section n x mm2 Crosssection of armour mm2 4,9 5,3 6,0 11,3 11,4 11,9 14,1 17,2 Diameter of screen mm Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 9,5 10,5 11,5 13,5 15,0 18,0 21,0 26,5 12,5 13,0 14,5 16,5 18,0 21,5 25,0 30,5 230 265 330 485 650 930 1310 1915 10 13 17 23 30 42 55 71 75 80 85 100 110 130 150 185 – 27914 27915 27916 27917 27918 27919 27920 – 28471 28472 28473 28474 28475 28476 28477 5x1,0 5x1,5 5x2,5 5x4 5x6 5x10 5x16 Flex 5x25 Flex – – – – – – – – – – – – – – – – – – – – 7x1,0 10x1,0 12x1,0 14x1,0 16x1,0 19x1,0 24x1,0 27x1,0 30x1,0 37x1,0 5,4 9,6 10,0 10,5 11,1 11,8 13,9 14,4 14,9 16,2 10,5 14,0 14,5 15,5 16,5 17,0 20,5 21,0 21,5 23,5 13,5 17,0 18,0 18,5 19,5 20,5 24,0 24,5 25,5 27,5 270 400 445 495 540 630 815 870 935 1090 9 8 8 7 7 7 6 6 6 5 80 105 105 110 115 125 145 150 155 165 27921 27923 27925 27927 27929 27931 27933 27935 – 27937 28478 28480 28482 28484 28486 28488 28490 28492 – 28494 7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 30x1,5 37x1,5 5,9 10,5 10,9 11,5 12,2 12,9 15,3 15,8 16,4 17,8 11,5 15,0 15,5 16,5 17,5 18,5 22,0 22,5 23,5 25,5 14,5 18,5 19,0 20,0 21,0 22,0 26,0 26,5 27,5 30,0 315 475 525 585 665 780 975 1055 1135 1345 12 11 10 10 9 9 8 8 7 7 85 110 115 120 125 135 155 160 165 180 27922 27924 27926 27928 27930 27932 27934 27936 – 27938 28479 28481 28483 28485 28487 28489 28491 28493 – 28495 7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 30x2,5 37x2,5 11,3 11,7 12,1 12,8 13,6 14,4 17,2 17,6 18,3 20,0 13,0 17,0 17,5 18,5 19,5 21,0 24,5 25,5 26,5 28,5 16,0 20,0 21,0 22,0 23,5 24,5 28,5 29,5 30,5 33,0 455 600 700 780 860 1020 1280 1410 1525 1790 16 14 13 12 12 11 10 10 10 9 95 120 125 135 140 150 170 180 185 200 Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 27 EMC CABLES 5/2016 EMC CABLES 28 RFE-EMC Armoured pair instrumentation and communication cable with improved EMC screening 250V 5/2016 DESIGN: STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Twisted pair - two insulated cores twisted together to form a pair See next page for Quad 4. Bedding - filler tape 5. Screen - drain wire copper (in all sizes) - copper tape 100% 6. Armour - copper wire braid, coverage >94% EC 60092-350 - tinned copper wire braid on request - the armour serves as a collective screen 7. Sheath - polyolefine plastic, SHF1 EC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Design to meet requirements for improved EMC screening properties. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant Halogen-free Smoke emission Oil resistance (only SHF2) Transfer impedance 150/250V (300V) + 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60754 series IEC 61034 series IEC 60811-404 conditions according to 60092-360/SHF2 IEC 61196-1 (typical value 26dB over 1mΩ/m at 100MHz [20mΩ/m]) Electrical data: Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C 0,5mm2 0,75mm2 80 52 55 50 0,6 0,6 ≥1500 ≥1500 1,5mm2 24,4 60 0,7 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: See technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 29 Part number Number of conductors & cross-section n x mm2 Nominal outer diameter mm Approximate weight kg/km Min. bending radius fixed installation mm 1x2x0,5 1x3x0,5 1x4x0,5 2x2x0,5 3x2x0,5 4x2x0,5 7x2x0,5 8x2x0,5 10x2x0,5 12x2x0,5 14x2x0,5 16x2x0,5 19x2x0,5 24x2x0,5 27x2x0,5 30x2x0,5 32x2x0,5 37x2x0,5 8,5 8,5 9,0 11,0 11,5 12,0 14,0 15,0 16,5 17,0 18,0 19,0 20,5 22,5 23,5 24,5 25,5 27,0 95 135 145 150 170 195 260 280 360 400 435 480 540 655 710 760 810 895 50 50 55 65 70 75 85 90 100 105 110 115 125 135 140 145 150 160 21987 21988 21989 21990 21991 21992 21993 21994 21995 21996 21997 21998 21999 22000 22001 22002 22003 22004 1x2x0,75 1x3x0,75 1x4x0,75 2x2x0,75 3x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 27x2x0,75 30x2x0,75 32x2x0,75 37x2x0,75 9,0 9,5 10,0 12,5 13,0 14,0 16,0 17,5 19,5 20,0 21,5 23,0 24,5 26,5 28,0 29,5 30,0 32,5 110 150 165 185 210 245 330 400 475 520 580 655 740 885 975 1055 1105 1265 55 55 60 75 75 85 95 105 115 120 130 135 145 160 170 175 180 195 22375 22376 22377 22378 22379 22380 22381 22382 22383 22384 22385 22386 22387 22388 22389 22390 22391 22392 1x2x1,5 1x3x1,5 1x4x1,5 2x2x1,5 3x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 24x2x1,5 27x2x1,5 30x2x1,5 32x2x1,5 37x2x1,5 11,5 12,0 12,5 15,5 16,5 18,0 21,5 23,0 25,5 27,0 28,5 30,5 32,5 36,5 38,0 40,0 41,0 44,5 170 210 240 280 325 425 605 690 820 930 1045 1165 1330 1640 1800 1975 2075 2480 70 70 75 95 100 110 130 140 155 160 170 180 195 220 230 240 245 265 Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 21968 21969 21970 21971 21972 21973 21974 21975 21976 21977 21978 21979 21980 21981 21982 21983 21984 21985 EMC CABLES RFE-EMC 250V EMC CABLES 30 RFE-EMC(i) 5/2016 DESIGN: Armoured and individually screened instrumentation and communication cable 250V STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Twisted pair & individual screen - two insulated cores twisted together to form a pair - plastic coated aluminium tape and a tinned copper drain wire 4. Bedding - filler tape 5. Screen - drain wire copper (in all sizes) - copper tape 100% 6. Armour - copper wire braid, coverage >94% IEC 60092-350 - tinned copper wire braid on request 7. Sheath - polyolefine plastic, SHF1 EC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Design to meet requirements for improved EMC screening properties. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant Halogen-free Smoke emission Oil resistance (only SHF2) Transfer impedance 150/250V (300V) + 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60754 series IEC 61034 series IEC 60811-404 conditions according to 60092-360/SHF2 IEC 61196-1 (typical value 26dB over 1mΩ/m at 100MHz [20mΩ/m]) Electrical data: Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C 0,5mm2 0,75mm2 80 52 55 70 0,6 0,6 ≥1500 ≥1500 1,5mm2 24,4 90 0,7 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: See technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 31 Part number 1x2x0,5 1x3x0,5 1x4x0,5 2x2x0,5 3x2x0,5 4x2x0,5 7x2x0,5 8x2x0,5 10x2x0,5 12x2x0,5 14x2x0,5 16x2x0,5 19x2x0,5 24x2x0,5 27x2x0,5 30x2x0,5 32x2x0,5 37x2x0,5 1x2x0,75 1x3x0,75 1x4x0,75 2x2x0,75 3x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 27x2x0,75 30x2x0,75 32x2x0,75 37x2x0,75 1x2x1,5 1x3x1,5 1x4x1,5 2x2x1,5 3x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 24x2x1,5 27x2x1,5 30x2x1,5 32x2x1,5 37x2x1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Nominal outer diameter mm Approximate weight kg/km Min. bending radius fixed installation mm 8,5 8,5 9,0 11,0 11,5 12,5 14,5 15,0 17,0 17,5 19,0 19,5 21,0 23,5 24,5 25,5 26,0 27,5 9,0 9,5 10,0 12,5 13,0 14,0 17,0 17,5 20,0 20,5 22,0 23,0 25,0 27,5 28,5 30,5 31,0 33,0 11,5 12,0 12,5 16,0 17,0 18,5 21,5 23,0 25,5 27,5 29,0 31,0 33,5 37,0 39,0 41,0 42,5 45,0 105 120 140 170 200 235 330 360 465 520 590 650 735 910 1000 1085 1140 1290 120 140 150 195 235 270 410 450 540 600 690 755 870 1045 1145 1270 1330 1490 180 205 240 295 390 465 670 760 910 1040 1185 1310 1530 1875 2060 2280 2505 2835 50 50 55 65 70 75 85 90 100 105 115 120 125 140 145 150 155 165 55 55 60 75 80 85 100 105 120 125 135 140 150 165 170 180 185 195 70 70 75 95 100 110 130 140 155 165 175 185 200 220 235 245 255 270 5/2016 21949 21950 21951 21952 21953 21954 21955 21956 21957 21958 21959 21960 21961 21962 21963 21964 21965 21966 21911 21912 21913 21914 21915 21916 21917 21918 21919 21920 21921 21922 21923 21924 21925 21926 21927 21928 21930 21931 21932 21933 21934 21935 21936 21937 21938 21939 21940 21941 21942 21943 21944 21945 21946 21947 Other sizes on request. Number of conductors & cross-section n x mm2 EMC CABLES RFE-EMC(i) 250V 5/2016 EMC CABLES 32 RFE-EMC-FRHF Fire-resistant armoured pair instrumentation and communication cable with improved EMC screening 250V DESIGN: STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic IEC 60092-360 Flame3. Twisted pair retardant - two insulated cores twisted together to form a pair FireSee next page for Quad resistant 4. Bedding Halogen- filler tape free 5. Screen Low smoke - drain wire copper (in all sizes) emission - copper tape 100% Oil resistant 6. Armour (only SHF2) - the armour serves as a collective screen - drain wire (in all sizes) - copper wire braid, coverage > 94% IEC 60092-350 - tinned copper wire braid on request 7. Sheath - polyolefine plastic, SHF1, standard colour orange IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Design to meet requirements for improved EMC screening properties. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant 150/250V (300V) + 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 0,75mm2 1,5mm2 Unit Electrical data 52 24,4 ohm/km Loop resistance of pair, max. / +20°C 45 55 nF/km Pair capacitance, nom. / 800Hz 0,6 0,7 mH/km Loop inductance, nom. ≥1500 ≥1500 Mohm/km Insulation resistance / +20°C Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 33 Part number 1x2x0,75 1x4x0,75 2x2x0,75 3x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 27x2x0,75 30x2x0,75 32x2x0,75 37x2x0,75 1x2x1,5 1x4x1,5 2x2x1,5 3x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 24x2x1,5 27x2x1,5 30x2x1,5 32x2x1,5 37x2x1,5 Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Nominal outer diameter mm Approximate weight kg/km Min. bending radius fixed installation mm 11,0 12,5 15,0 15,5 16,5 19,5 20,5 23,0 24,0 25,0 25,5 27,5 31,0 32,5 34,0 35,0 37,0 13,0 14,0 18,0 19,0 20,5 24,0 25,5 28,0 29,0 31,0 33,0 35,5 39,5 42,5 44,5 45,5 49,0 145 195 240 270 310 460 510 615 675 745 820 920 1130 1230 1345 1410 1570 210 275 400 450 500 730 800 965 1080 1210 1370 1560 1910 2285 2465 2660 2920 65 75 90 90 100 115 125 140 145 150 155 165 185 195 205 210 220 80 85 110 115 125 145 150 170 175 185 200 215 235 255 265 275 295 5/2016 22915 22917 22918 22919 22920 22921 22922 22923 22924 22925 22926 22927 22928 22929 22930 22931 22932 22934 22936 22937 22938 22939 22940 22941 22942 22943 22944 22945 22946 22947 22948 22949 22950 22951 Number of conductors & cross-section n x mm2 EMC CABLES RFE-EMC-FRHF 250V 5/2016 EMC CABLES 34 RFE-EMC-FRHF(i) Armoured and individually screened instrumentation and communication cable with improved EMC screening 250V DESIGN: STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic IEC 60092-360 Flame3. Twisted pair & individual screen retardant - two insulated cores twisted together to form a pair Fire- plastic coated aluminium tape and a tinned copper drain wire resistant 4. Bedding Halogen- filler tape free 4. Screen Low smoke - drain wire copper (in all sizes) emission - copper tape 100% Oil resistant (only SHF2) 5. Armour - drain wire copper - copper wire braid, coverage > 94% IEC 60092-350 - tinned copper wire braid on request 6. Sheath - polyolefine plastic, SHF1, standard colour orange IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Design to meet requirements for improved EMC screening properties. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant Fire-resistant Halogen-free Smoke emission Oil resistance (only SHF2) 150/250V (300V) + 90 °C IEC 60332-1-2 IEC 60332-3-22 -test for single insulated wire and cable -test for bunched wires and cables, category A IEC 60331-1 or IEC 60331-2 IEC 60754 series IEC 61034 series IEC 60811-404 conditions according to 60092-360/SHF2 Electrical data Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C 0,75mm2 1,5mm2 52 24,4 55 75 0,6 0,7 ≥1500 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 35 1x2x0,75 1x4x0,75 2x2x0,75 3x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 27x2x0,75 30x2x0,75 32x2x0,75 37x2x0,75 1x2x1,5 1x4x1,5 2x2x1,5 3x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 24x2x1,5 27x2x1,5 30x2x1,5 32x2x1,5 37x2x1,5 Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Approximate weight kg/km Min. bending radius fixed installation mm 10,5 12,5 15,5 16,0 18,0 21,0 22,0 25,5 26,5 28,5 30,0 32,0 36,0 37,5 39,5 40,5 43,0 12,0 13,5 17,5 18,0 20,0 23,5 25,5 28,5 30,5 32,0 34,0 36,5 41,5 43,5 46,0 47,0 50,0 145 200 250 295 385 540 590 730 825 920 1030 1170 1445 1580 1710 1820 2035 190 260 385 425 515 755 850 1030 1190 1340 1500 1715 2300 2505 2750 2855 3230 65 75 90 95 105 125 135 150 160 170 180 195 215 225 235 245 260 70 80 105 110 120 140 150 170 180 195 205 220 250 260 275 280 300 5/2016 22858 22860 22861 22862 22863 22864 22865 22866 22867 22868 22869 22870 22871 22872 22873 22874 22875 22877 22879 22880 22881 22882 22883 22884 22885 22886 22887 22888 22889 22890 22891 22892 22893 22894 Nominal outer diameter mm EMC CABLES Part number Number of conductors & cross-section n x mm2 RFE-EMC-FRHF(I) 250V 1,8/3kV CABLES 36 LKSM-VFD Armoured power and control cable with improved EMC screening 1,8/3kV 5/2016 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Bedding - filler tape 4. Screen - copper tape, coverage 100% 5. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request 6. Sheath - polyolefine plastic, SHF1 IEC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour black, other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units. Design to meet requirements for Variable Frequency Drivers (VFD). Suitable for voltage peaks up to 3kV. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant 1,8/3kV (3,6kV) Halogen-free Smoke emission + 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60754 series IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Transfer impedance IEC 61196-1 (typical value 26dB over 1mΩ/m at 100MHz [20mΩ/m]) For details see general information section Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: See technical information section. Cable with yellow/green protective earth (PE) conductor on request Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 37 1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 3x10 3x16 3x25 3x35 3x50 3x70 3x95 3x120 3x150 3x185 3x240 3x95+3x16 3x120+3x25 3x150+3x25 4,7 5,5 8,5 9,3 10,3 11,3 12,5 13,6 14,7 15,8 17,6 18,9 13,2 16,4 16,9 18,7 28,8 35,2 35,4 38,6 42,0 45,5 50,2 35,4 38,6 42,0 Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx NOTE! 1) = Protective earth (PE) rules are not fulfilled. (PE rules, for cables over 16mm2 the PEconductor have to be half of main conductor and min. 16mm2. This according to IEC 60092-352, Electrical installations in ships –Choice and installation of electrical cables) 2 = Three additional protective earth (PE) conductors. Protective earth (PE) rules are fulfilled. Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 12,5 14,0 16,0 17,0 19,0 20,5 23,5 25,5 27,5 29,5 33,0 35,0 23,5 26,5 29,5 32,5 37,0 41,0 46,5 50,5 55,0 60,0 67,0 46,5 50,5 55,0 280 355 495 625 795 995 1280 1525 1830 2165 2800 3365 880 1160 1525 1910 2580 3395 4295 5200 6255 7475 9620 4650 5755 6780 71 94 123 153 196 240 284 331 381 429 507 582 50 66 86 107 137 168 199 232 267 300 355 199 232 267 75 85 95 105 115 125 140 150 165 180 200 210 140 160 180 195 225 245 280 305 330 360 405 280 305 330 Note 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 2) 2) 2) 5/2016 26918 26920 26922 26924 26926 26928 26930 26932 26934 26936 26938 26940 26892 26871 26873 26875 26877 26879 26881 26883 26885 26887 26889 26893 26895 26897 Nominal outer diameter mm 1,8/3kV CABLES Part number Number of Crossconductors & section of cross-section armour n x mm2 mm2 LKSM-VFD 1,8/3kV 0,6/1kV CABLES 38 LKM-FRHF DESIGN: Fire-resistant unarmoured power and control cable 0,6/1kV STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,0–10mm2 IEC 60228, class 2 - stranded copper conductor 16–300mm2 IEC 60228, class 5 (Flex) - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic IEC 60092-360 5/2016 3. Bedding - separator tape 4. Sheath - polyolefine plastic, SHF1, standard colour orange IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 39 Part number Normal G-type – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 28279 28163 28165 28167 28169 28171 29367 29369 29371 29373 29375 29377 29379 29381 29383 29385 1x1,0 1x1,5 1x2,5 1x4 1x6 1x10 1x16 Flex 1x25 Flex 1x35 Flex 1x50 Flex 1x70 Flex 1x95 Flex 1x120 Flex 1x150 Flex 1x185 Flex 1x240 Flex 1x300 Flex 2x1,0 2x1,5 2x2,5 2x4 2x6 2x10 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 2x70 Flex 2x95 Flex 3x1,0 3x1,5 3x2,5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 3x150 Flex 3x185 Flex 3x240 Flex Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 5,5 5,5 6,0 6,5 7,5 8,5 9,5 11,5 12,5 14,5 16,5 18,5 20,5 23,5 25,5 28,5 32,0 8,5 9,0 10,5 11,5 12,5 15,0 17,5 21,5 23,5 27,5 31,5 35,5 8,5 9,5 11,0 12,0 13,5 16,0 18,5 23,0 25,0 29,5 34,0 38,0 42,5 48,5 53,5 60,5 40 45 60 80 105 150 200 305 400 555 765 985 1235 1555 1880 2495 3075 75 90 125 170 260 385 530 805 1070 1475 2030 2625 90 115 160 220 330 490 675 1030 1380 1915 2670 3425 4335 5450 6680 8840 18 23 30 40 52 72 94 123 153 196 240 284 331 381 429 507 582 15 20 26 34 44 61 80 105 130 167 204 241 13 16 21 28 36 50 66 86 107 137 168 199 232 267 300 355 30 35 35 40 45 50 40 50 55 60 70 75 85 95 155 175 195 50 55 60 70 75 90 70 90 95 165 190 215 50 60 65 75 80 95 75 95 155 180 205 230 255 290 325 365 G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Table continues on next page 5/2016 28275 28100 28102 28104 28106 28108 29326 29327 29328 29329 29330 29331 29332 29333 29334 29335 29336 28276 28132 28134 28136 28138 28140 29343 29344 29345 29346 29347 29348 28278 28162 28164 28166 28168 28170 29366 29368 29370 29372 29374 29376 29378 29380 29382 29384 Number of conductors & cross-section n x mm2 0,6/1kV CABLES LKM-FRHF 0,6/1kV 5/2016 0,6/1kV CABLES 40 LKM-FRHF 0,6/1kV Part number Normal G-type 28280 28182 28184 28186 28188 28190 29400 29402 29404 29406 29408 29410 28282 28212 28214 28501 28503 28505 29434 29436 29438 29440 29442 28281 28183 28185 28187 28189 28191 29401 29403 29405 29407 29409 29411 28283 28213 28215 28502 28504 28506 29435 29437 29439 29441 29443 Number of conductors & cross-section n x mm2 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 4x1,0 4x1,5 4x2,5 4x4 4x6 4x10 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 4x95 Flex 5x1,0 5x1,5 5x2,5 5x4 5x6 5x10 5x16 Flex 5x25 Flex 5x35 Flex 5x50 Flex 5x70 Flex 9,5 11,0 12,0 13,5 15,0 17,5 20,5 25,5 28,0 33,0 38,0 42,5 11,0 12,0 13,0 15,0 16,5 19,5 22,5 28,5 31,0 36,5 42,5 115 150 200 280 410 620 865 1330 1760 2465 3420 4435 145 180 240 345 505 755 1050 1630 2175 3040 4265 13 16 21 28 36 50 66 86 107 137 168 199 10 13 17 23 30 42 55 71 89 114 139 55 65 70 80 90 105 85 155 170 200 230 255 65 70 80 90 100 115 95 175 185 220 255 G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Table continues on next page 41 Part number Normal G-type 28285 28287 28289 28291 28293 28295 28297 28299 28301 28217 28241 28221 28245 28249 28225 28229 28233 28235 28219 28243 28223 28247 28251 28227 28231 28237 28239 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 12,0 15,0 15,5 16,5 17,5 18,5 21,5 22,0 25,0 13,0 16,5 17,5 18,5 19,5 20,5 24,5 25,0 28,0 14,5 18,5 19,5 20,5 21,5 23,0 27,5 28,0 31,5 180 260 295 330 380 435 550 600 805 230 330 380 430 485 565 725 795 1050 315 450 510 590 670 765 995 1095 1450 9 8 8 7 7 7 6 6 5 12 11 10 10 9 9 8 8 7 16 14 13 13 12 11 10 10 9 70 90 95 100 105 110 130 130 150 80 100 105 110 115 125 145 150 170 90 110 115 125 130 135 165 170 190 7x1,0 10x1,0 12x1,0 14x1,0 16x1,0 19x1,0 24x1,0 27x1,0 37x1,0 7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 37x1,5 7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 37x2,5 Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 28284 28286 28288 28290 28292 28294 28296 28298 28300 28216 28240 28220 28244 28248 28224 28228 28232 28234 28218 28242 28222 28246 28250 28226 28230 28236 28238 Number of conductors & cross-section n x mm2 0,6/1kV CABLES LKM-FRHF 0,6/1kV 5/2016 0,6/1kV CABLES 42 LKMM-FRHF Fire-resistant unarmoured power cable with extruded filler 0,6/1kV DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded copper conductor 16–150mm2 IEC 60228, class 5 - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic IEC 60092-360 3. Bedding - extruded filler 4. Sheath - polyolefine plastic, SHF1, standard colour orange IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units. Main characteristics Rated voltage AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 43 Part number Normal G-type – – – – – – – – – – 29551 29553 29555 29557 29559 29561 29563 29565 29567 29569 29571 29573 29575 29577 29579 29585 29587 29589 29591 29593 29595 29597 29599 29601 29603 29619 29621 29623 29625 29627 29629 29631 2x1,5 2x2,5 2x4 2x6 2x10 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 2x70 Flex 3x1,5 3x2,5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 3x150 Flex 3x185 Flex 3x240 Flex 4x1,5 4x2,5 4x4 4x6 4x10 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 5x1,5 5x2,5 5x4 5x6 5x10 5x16 Flex 5x25 Flex Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 12,0 13,0 13,5 15,5 17,0 20,0 24,5 26,0 30,5 35,5 12,0 13,0 15,0 15,5 18,0 20,5 26,0 28,5 32,5 38,5 43,5 48,0 54,5 61,0 70,0 13,0 14,0 15,5 17,0 20,5 23,5 28,5 30,5 37,0 42,5 14,0 16,0 17,5 18,5 21,5 25,5 30,5 165 195 250 315 440 570 840 1145 1555 2095 190 240 305 395 560 735 1095 1475 2015 2805 3630 4535 5720 7010 9220 230 285 370 490 700 940 1380 1860 2580 3545 270 335 450 585 850 1145 1710 23 30 40 52 72 94 123 153 196 240 23 30 40 52 72 94 123 153 196 240 284 331 381 429 507 23 30 40 52 72 94 123 153 196 240 23 30 40 52 72 94 123 70 75 85 90 105 120 145 160 185 210 75 80 90 95 110 125 155 170 195 230 265 290 330 370 420 80 85 95 105 120 140 170 185 220 250 85 95 105 115 130 150 185 Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 29532 29533 29534 29535 29536 29537 29538 29539 29540 29541 29550 29552 29554 29556 29558 29560 29562 29564 29566 29568 29570 29572 29574 29576 29578 29584 29586 29588 29590 29592 29594 29596 29598 29600 29602 29618 29620 29622 29624 29626 29628 29630 Number of conductors & cross-section n x mm2 0,6/1kV CABLES LKMM-FRHF 0,6/1kV 0,6/1kV CABLES 44 LKSM-FRHF 5/2016 DESIGN: Fire-resistant armoured power and control cable 0,6/1kV STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,0–10mm2 IEC 60228, class 2 - stranded copper conductor 16–300mm2 IEC 60228, class 5 (Flex) - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic EC 60092-360 3. Bedding - separator tape 4. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request 5. Sheath - polyolefine plastic, SHF1, standard colour orange IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 45 Part number Normal G-type Number of conductors & cross-section n x mm2 Crosssection of armour mm2 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm – – – – – – 27058 27060 27062 27064 27066 27068 27070 27072 27074 27076 27078 1x1,0 1x1,5 1x2,5 1x4 1x6 1x10 1x16 Flex 1x25 Flex 1x35 Flex 1x50 Flex 1x70 Flex 1x95 Flex 1x120 Flex 1x150 Flex 1x185 Flex 1x240 Flex 1x300 Flex 3,0 3,0 3,1 3,1 3,1 3,5 4,1 5,2 5,5 8,7 11,4 11,5 12,3 14,7 15,2 18,2 18,7 6,5 6,5 7,0 7,5 8,5 9,5 11,0 13,5 14,5 16,5 19,0 20,5 22,5 25,5 27,5 30,5 34,0 75 80 95 115 140 200 255 380 475 660 905 1125 1395 1735 2065 2710 3315 18 23 30 40 52 72 94 123 153 196 240 284 331 381 429 507 582 40 40 45 45 50 60 65 85 90 100 115 125 140 155 170 185 210 28542 28602 28604 28606 28608 28610 29071 29072 29073 29074 29075 29076 – – – – – – – – – – – – 2x1,0 2x1,5 2x2,5 2x4 2x6 2x10 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 2x70 Flex 2x95 Flex 3,5 3,8 4,3 4,9 5,4 8,7 10,0 14,5 14,7 18,1 18,7 22,2 9,5 10,5 11,5 12,5 14,0 16,5 19,0 23,5 25,5 29,5 33,5 37,0 120 140 170 225 345 510 670 1035 1275 1715 2300 2900 15 20 26 34 44 61 80 105 130 167 204 241 60 65 70 75 85 100 115 145 155 180 205 225 28543 28622 28624 28626 28628 28630 29082 29084 29086 29088 29090 29092 29094 29096 29098 29100 28544 28623 28625 28627 28629 28631 29083 29085 29087 29089 29091 29093 29095 29097 29099 29101 3x1,0 3x1,5 3x2,5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 3x150 Flex 3x185 Flex 3x240 Flex 4,1 4,1 4,6 5,2 5,8 9,3 10,7 14,6 15,0 17,5 22,0 22,8 37,8 39,3 47,9 50,7 10,0 11,0 12,0 13,5 14,5 17,5 20,0 25,0 27,0 31,5 36,0 40,0 45,0 51,0 56,0 63,0 145 170 210 280 400 605 800 1225 1550 2125 2900 3660 4710 5850 7145 9315 13 16 21 28 36 50 66 86 107 137 168 199 232 267 300 355 60 65 70 80 90 105 120 155 165 190 220 240 270 310 340 380 28545 28642 28644 28646 28648 28650 29104 29106 29108 29110 29112 29114 29116 29118 28546 28643 28645 28647 28649 28651 29105 29107 29109 29111 29113 29115 29117 29119 4x1,0 4x1,5 4x2,5 4x4 4x6 4x10 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 4x95 Flex 4x120 Flex 4x150 Flex 4,1 4,5 5,0 5,8 8,8 10,3 11,9 14,8 18,1 19,5 22,6 35,0 39,3 48,2 11,0 12,0 13,5 14,5 16,5 19,0 22,5 27,5 30,0 35,0 40,0 45,0 49,5 56,5 170 200 260 345 515 735 1010 1515 1960 2685 3655 4795 5980 7540 13 16 21 28 36 50 66 86 107 137 168 199 232 267 65 70 80 85 100 115 135 170 180 210 240 270 300 340 G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Table continues on next page 5/2016 28541 28568 28570 28572 28574 28576 29060 29061 29062 29063 29064 29065 29066 29067 29068 29069 29070 0,6/1kV CABLES LKSM-FRHF 0,6/1kV 5/2016 0,6/1kV CABLES 46 LKSM-FRHF 0,6/1kV Part number Normal G-type Number of conductors & cross-section n x mm2 Crosssection of armour mm2 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 28547 28662 28664 28705 28707 28709 29126 29128 29130 29132 28548 28663 28665 28706 28708 28710 29127 29129 29131 29133 5x1,0 5x1,5 5x2,5 5x4 5x6 5x10 5x16 Flex 5x25 Flex 5x35 Flex 5x50 Flex 4,5 5,0 5,6 8,6 9,7 11,5 13,2 18,1 18,6 22,4 12,0 13,0 14,5 16,5 18,0 21,0 24,5 30,5 33,0 38,5 195 245 305 445 605 880 1135 1740 2370 3240 10 13 17 23 30 42 55 71 89 114 70 80 85 100 105 125 150 185 200 230 28549 28551 28553 28555 28557 28559 28561 28563 28565 28550 28552 28554 28556 28558 28560 28562 28564 28566 7x1,0 10x1,0 12x1,0 14x1,0 16x1,0 19x1,0 24x1,0 27x1,0 37x1,0 4,9 8,7 9,0 11,4 11,4 11,4 12,5 12,8 14,4 13,0 16,5 17,0 18,0 19,0 20,0 23,5 24,0 26,5 240 355 395 455 505 555 695 750 960 9 8 8 7 7 7 6 6 5 80 100 100 105 115 120 140 145 160 28666 28723 28670 28727 28731 28674 28678 28682 28684 28667 28724 28671 28728 28732 28675 28679 28683 28685 7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 37x1,5 5,4 9,6 9,9 11,4 11,5 11,7 13,9 14,1 16,0 14,5 18,0 19,0 20,0 21,0 22,0 26,0 26,5 29,5 295 430 490 555 615 680 875 950 1220 12 11 10 10 9 9 8 8 7 85 110 115 120 125 130 155 160 180 28668 28725 28672 28729 28733 28676 28680 28686 28688 28669 28726 28673 28730 28734 28677 28681 28687 28689 7x2,5 12x2,5 10x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 37x2,5 8,5 11,5 11,5 11,8 12,5 13,2 15,7 16,1 18,1 16,0 20,0 21,0 22,5 23,5 24,5 29,0 29,5 33,0 405 570 635 735 820 920 1165 1270 1660 16 14 13 13 12 11 10 10 9 95 120 125 135 140 145 175 175 200 Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 47 0,6/1kV CABLES 5/2016 0,6/1kV CABLES 48 LKMSM-FRHF 5/2016 DESIGN: Fire-resistant armoured power cable with extruded filler 0,6/1kV STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded copper conductor 16–150mm2 IEC 60228, class 5 - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic IEC 60092-360 3. Bedding - extruded filler 4. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid and galvanized steel wire braid on request 5. Sheath - polyolefine plastic, SHF1, standard colour orange IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units. Main characteristics Rated voltage AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 49 Crosssection of armour mm2 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Part number Normal G-type Min. bending radius fixed installation mm – – – – – – – – – 2x1,5 2x2,5 2x4 2x6 2x10 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 5,3 5,8 6,6 9,8 11,4 13,0 16,1 17,2 20,0 13,0 13,0 15,0 16,5 18,0 20,5 25,5 26,5 30,5 215 255 315 410 550 695 990 1285 1695 20 26 34 44 61 80 105 130 167 75 80 90 95 110 125 150 160 185 29732 29734 29736 29738 29740 29743 29745 29747 29749 29751 29753 29755 29757 29733 29735 29737 29739 29741 29744 29746 29748 29750 29752 29754 29756 29758 3x1,5 3x2,5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 3x150 Flex 5,7 6,3 9,4 10,4 12,1 13,9 17,1 18,4 21,4 25,2 38,3 42,7 48,9 13,5 14,0 16,0 16,5 19,0 21,5 27,0 29,0 33,0 38,5 42,5 46,5 53,0 245 300 395 490 675 865 1250 1620 2165 2985 3850 4775 5990 16 21 28 36 50 66 86 107 137 168 199 232 267 80 85 95 100 115 130 160 170 195 230 255 280 320 29767 29769 29771 29773 29775 29777 29779 29781 29783 29785 29787 29789 29768 29770 29772 29774 29776 29778 29780 29782 29784 29786 29788 29790 4x1,5 4x2,5 4x4 4x6 4x10 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 4x95 Flex 4x120 Flex 6,2 6,7 10,3 11,4 13,3 15,3 18,9 20,4 23,7 38,4 42,5 47,7 14,5 15,0 16,5 18,0 21,5 24,0 29,5 31,0 36,0 42,0 46,5 52,5 290 350 465 595 825 1080 1555 2015 2740 3845 4875 6085 16 21 28 36 50 66 86 107 137 168 199 232 85 90 100 110 125 145 175 190 220 255 280 315 29801 29803 29805 29807 29809 29811 29813 29802 29804 29806 29808 29810 29812 29814 5x1,5 5x2,5 5x4 5x6 5x10 5x16 Flex 5x25 Flex 6,7 10,1 11,2 12,5 14,6 16,8 20,9 15,5 17,0 18,0 19,5 22,5 26,0 31,5 335 435 555 700 985 1295 1890 13 17 23 30 42 55 71 90 100 110 120 135 160 190 Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 29715 29716 29717 29718 29719 29720 29721 29722 29723 0,6/1kV CABLES conductors & cross-section n x mm2 LKMSM-FRHF 0,6/1kV Number of 0,6/1kV CABLES 50 LKAM-FRHF DESIGN: Fire-resistant screened power and control cable 0,6/1kV STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic IEC 60092-360 5/2016 3. Screen - drain wire of tinned copper 1,0mm2 (in all sizes) - aluminium polyester tape, IEC 60092-350 coverage 100% Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) 4. Sheath - polyolefine plastic, SHF1, standard colour orange IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request Application: For fixed installation in most areas and on open deck in ships and offshore units, especially when lightweight cables are needed. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 51 Part number Normal G-type – 28744 28748 28752 28756 28760 28764 28768 28772 28776 28780 28784 28788 – 28746 28750 28754 28758 28762 28766 28770 28774 28778 28782 28786 28790 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 2x1,5 3x1,5 4x1,5 5x1,5 7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 37x1,5 2x2,5 3x2,5 4x2,5 5x2,5 7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 37x2,5 9,5 10,0 11,0 12,0 13,5 17,0 17,5 18,5 19,5 20,5 24,5 25,0 28,0 10,5 11,0 12,0 13,5 14,5 19,0 19,5 20,5 21,5 23,0 27,0 28,0 31,5 110 135 165 200 250 350 400 450 515 580 745 815 1070 140 175 215 270 335 485 555 630 705 825 1045 1145 1515 20 16 16 13 12 11 10 10 9 9 8 8 7 26 21 21 17 16 14 13 13 12 11 10 10 9 60 60 65 70 80 100 105 110 115 125 145 150 170 65 65 75 80 90 115 115 125 130 140 165 165 190 Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 28741 28743 28747 28751 28755 28759 28763 28767 28771 28775 28779 28783 28787 28742 28745 28749 28753 28757 28761 28765 28769 28773 28777 28781 28785 28789 Number of conductors & cross-section n x mm2 0,6/1kV CABLES LKAM-FRHF 0,6/1kV 250V CABLES 52 LKM-HF Unarmoured control and instrumentation cable 250V DESIGN: STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 5/2016 3. Bedding - separator tape 4. Sheath - polyolefine plastic, SHF1 EC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units.If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.. Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: black numbers on white base Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 53 Part number Nominal outer diameter mm 2x0,5 3x0,5 4x0,5 5x0,5 7x0,5 10x0,5 12x0,5 14x0,5 16x0,5 19x0,5 20x0,5 24x0,5 27x0,5 32x0,5 37x0,5 2x0,75 3x0,75 4x0,75 5x0,75 7x0,75 10x0,75 12x0,75 14x0,75 16x0,75 19x0,75 20x0,75 24x0,75 27x0,75 32x0,75 37x0,75 5,5 6,0 6,5 7,0 7,5 9,5 10,0 10,0 11,0 11,0 12,0 13,0 13,5 14,0 15,0 6,5 7,0 7,5 8,0 8,5 11,0 11,5 12,5 13,0 13,5 14,5 16,0 16,0 16,5 18,0 Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Approximate weight kg/km 35 45 55 65 75 115 125 140 160 180 190 225 245 280 315 50 60 70 85 105 155 175 200 225 255 275 320 350 400 460 Current Rating A at +45°C 8,7 7,6 6,9 6,4 5,8 5,1 4,8 4,6 4,4 4,1 4,1 3,8 3,7 3,5 3,3 11,3 9,8 8,9 8,3 7,4 6,6 6,2 5,9 5,6 5,3 5,2 4,9 4,7 4,5 4,3 Min. bending radius fixed installation mm 25 25 25 30 30 40 40 40 45 45 45 55 55 55 60 25 25 30 30 35 45 45 50 50 55 55 65 65 65 75 5/2016 27821 27822 27823 27824 27825 27826 27827 27828 27829 27830 27831 27832 27833 27834 27835 26365 26366 26367 26368 26369 26370 26371 26372 26373 26374 26375 26376 26377 26378 26379 Number of conductors & cross-section n x mm2 250V CABLES LKM-HF 250V 250V CABLES 54 LKSM-HF Armoured control and instrumentation cable 250V 5/2016 DESIGN: STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Bedding - separator tape 4. Armour - drain wire copper (in all sizes) - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request -the armour serves as a collective screen 5. Sheath - polyolefine plastic, SHF1 EC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: black numbers on white base Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 55 Part number 2x0,5 3x0,5 4x0,5 5x0,5 7x0,5 10x0,5 12x0,5 14x0,5 16x0,5 19x0,5 20x0,5 24x0,5 27x0,5 32x0,5 37x0,5 2x0,75 3x0,75 4x0,75 5x0,75 7x0,75 10x0,75 12x0,75 14x0,75 16x0,75 19x0,75 20x0,75 24x0,75 27x0,75 32x0,75 37x0,75 Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Crosssection of armour mm2 3,0 3,0 2,6 3,1 3,2 4,2 4,3 4,5 5,3 5,3 5,5 6,1 6,3 8,9 9,7 3,1 3,1 3,2 3,6 3,9 5,3 5,3 5,6 5,9 6,3 10,9 10,2 10,5 10,9 11,8 Nominal outer diameter mm 6,5 7,0 7,5 8,0 8,5 10,5 10,5 11,0 11,5 12,5 13,0 14,0 14,5 15,0 16,0 7,5 7,5 8,0 9,5 10,0 12,0 12,5 13,0 13,5 14,5 18,0 17,0 17,5 18,0 19,5 Approximate weight kg/km 75 80 85 100 115 160 175 195 215 240 260 290 315 380 425 85 95 110 135 155 215 235 260 290 320 440 425 460 520 580 Current Rating A at +45°C Min. bending radius fixed installation mm 8,7 7,6 6,9 6,4 5,8 5,1 4,8 4,6 4,4 4,1 4,1 3,8 3,7 3,5 3,3 11,3 9,8 8,9 8,3 7,4 6,6 6,2 5,9 5,6 5,3 5,2 4,9 4,7 4,5 4,3 40 40 45 45 50 60 65 65 70 75 80 85 85 90 95 45 45 50 55 60 75 75 80 80 85 105 100 105 110 115 5/2016 27779 27780 27781 27782 27783 27784 27785 27786 27787 27788 27789 27790 27791 27792 27793 26402 26403 26404 26405 26407 26410 26412 26414 26416 26419 26420 26424 26427 26432 26437 Number of conductors & cross-section n x mm2 250V CABLES LKSM-HF 250V 250V CABLES 56 LKAM-HF Screened control and instrumentation cable 250V DESIGN: STANDARDS: IEC 60092-376, design 5/2016 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Screen - drain wire of tinned copper - aluminium polyester tape, coverage 100% IEC 60092-350 4. Sheath - polyolefine plastic, SHF1 EC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units, especially when lightweight cables are needed. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: black numbers on white base Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 57 Part number Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 2x0,5 3x0,5 4x0,5 5x0,5 7x0,5 10x0,5 12x0,5 14x0,5 16x0,5 19x0,5 20x0,5 24x0,5 27x0,5 32x0,5 37x0,5 2x0,75 3x0,75 4x0,75 5x0,75 7x0,75 10x0,75 12x0,75 14x0,75 16x0,75 19x0,75 20x0,75 24x0,75 27x0,75 32x0,75 37x0,75 5,5 6,0 6,5 7,0 7,5 9,5 10,0 10,5 11,0 11,5 12,0 13,0 13,5 14,0 15,0 6,5 7,0 7,5 8,0 9,0 11,0 12,0 12,5 13,0 13,5 14,5 16,0 16,0 17,0 18,0 40 50 60 70 80 120 130 145 165 185 205 230 250 290 330 55 65 75 90 120 160 185 205 230 260 285 325 355 415 465 8,7 7,6 6,9 6,4 5,8 5,1 4,8 4,6 4,4 4,1 4,1 3,8 3,7 3,5 3,3 11,3 9,8 8,9 8,3 7,4 6,6 6,2 5,9 5,6 5,3 5,2 4,9 4,7 4,5 4,3 25 25 25 30 30 40 40 40 45 45 50 55 55 55 60 25 30 30 30 35 45 45 50 50 55 60 65 65 70 75 Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 26440 26441 26442 26443 26444 26445 26446 26447 26448 26449 26450 26451 26452 26453 26454 26382 26383 26384 26385 26386 26387 26388 26389 26390 26391 26392 26393 26394 26395 26396 Number of conductors & cross-section n x mm2 250V CABLES LKAM-HF 250V 250V CABLES 58 RFE-HF Armoured pair instrumentation and communication cable 250V 5/2016 DESIGN: STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Twisted pair - two insulated cores twisted together to form a pair See next page for Quad 4. Bedding - filler tape 5. Armour - drain wire copper (in all sizes) - copper wire braid, coverage > 94% IEC 60092-350 - tinned copper wire braid on request - the armour serves as a collective screen 6. Sheath - polyolefine plastic, SHF1 EC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant 150/250V (300V) Halogen-free Smoke emission + 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60754 series IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Electrical data: Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C 0,5mm2 0,75mm2 80 52 55 50 0,6 0,6 ≥1500 ≥1500 1,5mm2 24,4 60 0,7 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 59 Part number Nominal outer diameter mm Approximate weight kg/km Min. bending radius fixed installation mm 6,5 7,5 9,5 10,5 12,5 13,5 15,5 16,0 17,0 18,0 19,0 21,5 7,5 8,5 11,0 12,5 15,0 16,0 18,0 19,0 20,0 21,5 23,0 25,5 29,0 10,0 10,5 14,5 17,0 20,0 21,5 24,5 26,0 27,5 29,0 31,5 35,0 40,0 75 90 120 155 220 240 315 350 390 435 490 600 90 115 150 205 290 350 425 475 530 600 680 820 1035 140 185 235 380 555 635 770 865 975 1095 1250 1555 1980 40 45 55 65 75 80 90 95 100 110 115 130 45 50 65 75 90 95 110 115 120 130 140 155 175 60 65 85 100 120 130 150 155 165 175 190 210 240 1x2x0,5 1x2x0,5 Quad 2x2x0,5 4x2x0,5 7x2x0,5 8x2x0,5 10x2x0,5 12x2x0,5 14x2x0,5 16x2x0,5 19x2x0,5 24x2x0,5 1x2x0,75 1x4x0,75 Quad 2x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 32x2x0,75 1x2x1,5 1x2x1,5 Quad 2x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 24x2x1,5 32x2x1,5 Other sizes on request. Core identification Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... (Quad)cable is built up as a star quad with the following identification 1 core white 2 core blue 3 core white 4 core blue Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 20362 20364 20363 20366 20368 20369 20370 20371 20372 20373 20374 20376 20382 20384 20383 20386 20388 20389 20390 20391 20392 20393 20394 20396 20398 20490 20491 20492 20493 20494 20495 20496 20497 20498 20503 20499 20500 20501 Number of conductors & cross-section n x mm2 250V CABLES RFE-HF 250V 250V CABLES 60 RFE-HF (i) 5/2016 DESIGN: Armoured and individually screened instrumentation and communication cable 250V STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Twisted pair & individual screen - two insulated cores twisted together to form a pair - plastic coated aluminium tape and a tinned copper drain wire 4. Bedding - filler tape 5. Armour - drain wire copper (in all sizes) - copper wire braid, coverage > 94% IEC 60092-350 - tinned copper wire braid on request 6. Sheath - polyolefine plastic, SHF1 IEC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant 150/250V (300V) Halogen-free Smoke emission + 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60754 series IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Electrical data: Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C 0,5mm2 0,75mm2 80 52 55 70 0,6 0,6 ≥1500 ≥1500 1,5mm2 24,4 90 0,7 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 61 Approximate weight kg/km Min. bending radius fixed installation mm 22338 22342 22344 22346 22348 22350 22352 22354 22356 22358 22360 22362 22364 22366 22368 22370 22372 1x2x0,5 2x2x0,5 Quad 2x2x0,5 3x2x0,5 4x2x0,5 7x2x0,5 8x2x0,5 10x2x0,5 12x2x0,5 14x2x0,5 16x2x0,5 19x2x0,5 24x2x0,5 27x2x0,5 30x2x0,5 32x2x0,5 37x2x0,5 7,0 7,5 9,5 10,0 11,0 13,0 13,5 15,5 16,5 17,5 18,5 19,5 22,0 23,0 24,0 24,5 26,5 85 115 140 165 205 295 325 420 475 540 600 685 855 940 1020 1075 1225 40 45 60 60 65 75 80 95 100 105 110 120 135 140 145 150 160 22006 22008 22010 22012 22014 22016 22018 22020 22022 22024 22026 22028 22050 22052 22054 22056 22058 22060 22062 22064 22066 22068 22070 22072 1x2x0,75 2x2x0,75 Quad 2x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 19x2x0,75 24x2x0,75 32x2x0,75 1x2x1,5 2x2x1,5 Quad 2x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 19x2x1,5 24x2x1,5 32x2x1,5 7,5 8,5 11,0 13,0 15,5 16,5 18,5 19,5 21,0 23,5 26,0 30,0 10,0 11,0 14,5 17,0 20,5 22,0 25,0 26,0 28,0 32,0 36,0 41,0 95 125 165 235 365 400 485 550 635 810 980 1255 150 205 255 415 615 705 860 975 1110 1450 1785 2395 45 50 65 75 95 100 110 115 125 140 155 180 60 65 85 105 120 130 150 155 170 195 215 245 Part number Other sizes on request. Core identification Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....) Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 Nominal outer diameter mm 250V CABLES Number of conductors & cross-section n x mm2 RFE-HF(i) 250V 250V CABLES 62 RFA-HF Screened pair instrumentation and communication cable 250V 5/2016 DESIGN: STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Twisted pair - two insulated cores twisted together to form a pair See next page for Quad 4. Collective screen - drain wire tinned copper - aluminium polyester tape IEC 60092-350 coverage 100% 5. Sheath - polyolefine plastic, SHF1 EC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units, especially when lightweight cables are needed. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant Halogen-free Smoke emission Oil resistance (only SHF2) 150/250V (300V) + 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60754 series IEC 61034 series IEC 60811-404 conditions according to 60092-360/SHF2 Electrical data Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C 0,5mm2 0,75mm2 80 52 55 50 0,6 0,6 ≥1500 ≥1500 1,5mm2 24,4 60 0,7 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 63 Part number Nominal outer diameter mm 1x2x0,5 2x2x0,5 Quad 2x2x0,5 3x2x0,5 4x2x0,5 7x2x0,5 8x2x0,5 10x2x0,5 12x2x0,5 14x2x0,5 16x2x0,5 19x2x0,5 24x2x0,5 32x2x0,5 37x2x0,5 1x2x0,75 2x2x0,75 Quad 2x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 32x2x0,75 37x2x0,75 1x2x1,5 2x2x1,5 Quad 2x2x1,5 3x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 24x2x1,5 27x2x1,5 30x2x1,5 32x2x1,5 37x2x1,5 5,5 6,5 8,0 9,0 9,5 11,5 12,5 14,0 14,5 15,5 16,5 18,0 20,0 23,0 24,5 6,5 7,5 10,0 11,5 14,0 15,0 17,0 17,5 19,0 20,5 22,0 24,0 27,5 30,0 8,5 10,0 13,5 14,0 15,5 18,5 20,0 23,0 24,5 26,0 27,5 30,0 33,5 35,5 37,5 38,5 41,0 Approximate weight kg/km Min. bending radius fixed installation mm 40 60 70 90 110 155 180 220 250 280 310 365 460 590 665 55 75 95 145 220 250 310 355 400 465 530 655 845 980 85 140 170 215 265 415 475 600 685 795 890 1045 1305 1465 1600 1715 1945 35 40 50 55 60 70 75 85 90 95 100 105 120 135 145 40 45 60 70 85 90 100 105 115 120 130 145 165 180 50 60 80 85 90 110 120 140 145 155 165 180 200 215 225 230 245 Other sizes on request. Core identification Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... (Quad)cable is built up as a star quad with the following identification 1 core white 2 core blue 3 core white 4 core blue Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 20910 20912 20914 20906 20916 20918 20920 20922 20924 20926 20928 20930 20932 20934 20936 20970 20972 20974 20976 20978 20980 20982 20984 20986 20988 20990 20992 20994 20996 21356 21358 21359 21360 21361 21362 21363 21364 21365 21366 21367 21368 21369 21370 21371 21372 21373 Number of conductors & cross-section n x mm2 250V CABLES RFA-HF 250V 250V CABLES 64 RFA-HF (i) 5/2016 DESIGN: Collectively and individually screened instrumentation and communication cable 250 V STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Twisted pair & individual screen - two insulated cores twisted together to form a pair - plastic coated aluminium tape and a tinned copper drain wire 4. Bedding - separator tape 5. Collective screen - drain wire tinned copper IEC 60092-350 - aluminium polyester tape, coverage 100% 6. Sheath - polyolefine plastic, SHF1 EC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units, especially when lightweight cables are needed. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant Halogen-free Smoke emission Oil resistance (only SHF2) 150/250V (300V) + 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60754 series IEC 61034 series IEC 60811-404 conditions according to 60092-360/SHF2 Electrical data Loop resistance of pair, max. / +20°C Pair capacitance, nom. Loop inductance, nom. Insulation resistance / +20°C 0,5mm2 0,75mm2 80 52 55 70 0,6 0,6 ≥1500 ≥1500 1,5mm2 24,4 90 0,7 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 65 Part number 2x2x0,5 4x2x0,5 7x2x0,5 8x2x0,5 10x2x0,5 12x2x0,5 14x2x0,5 16x2x0,5 19x2x0,5 24x2x0,5 32x2x0,5 37x2x0,5 1x2x0,75 2x2x0,75 3x2x0,75 4x2x0,75 5x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 1x2x1,5 2x2x1,5 Quad 2x2x1,5 3x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 24x2x1,5 27x2x1,5 30x2x1,5 32x2x1,5 37x2x1,5 Nominal outer diameter mm Approximate weight kg/km Min. bending radius fixed installation mm 8,5 10,0 12,0 12,5 14,5 15,0 16,0 17,0 18,5 20,5 23,5 25,0 6,5 10,0 10,5 11,5 13,0 14,0 15,0 17,0 18,0 19,0 20,5 22,0 24,5 8,5 10,0 13,5 14,0 16,0 19,0 20,5 23,5 25,0 26,5 28,5 30,5 34,5 36,5 38,0 39,5 42,0 80 130 200 225 280 320 360 405 475 600 775 880 60 110 140 170 205 260 300 370 425 485 560 645 800 95 155 190 240 310 485 565 695 805 915 1045 1210 1535 1715 1885 2030 2305 50 60 70 75 85 90 95 100 110 125 140 150 40 60 65 70 75 85 90 105 110 115 125 135 150 50 60 80 85 95 115 125 140 150 160 170 185 205 220 230 235 250 Other sizes on request. Core identification Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... The pairs are covered by a numbered tape (1, 2, 3, 4, 5....) Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 20940 20942 20944 20946 20948 20950 20952 20954 20956 20958 20960 20962 21058 21059 21100 21061 21115 21063 21065 21067 21069 21071 21073 21075 21077 21375 21377 21378 21379 21380 21381 21382 21383 21384 21385 21386 21387 21388 21389 21390 21391 21392 Number of conductors & cross-section n x mm2 250V CABLES RFA-HF(i) 250V 250V CABLES 66 LKM-FRHF DESIGN: Fire-resistant unarmoured control and instrumentation cable 250V STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic IEC 60092-360 5/2016 3. Bedding - separator tape Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) 4. Sheath - polyolefine plastic, SHF1, standard colour orange IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: black numbers on white base Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 67 Part number Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 2x0,75 3x0,75 4x0,75 5x0,75 7x0,75 10x0,75 12x0,75 14x0,75 16x0,75 19x0,75 20x0,75 24x0,75 27x0,75 32x0,75 37x0,75 8,0 8,5 9,5 10,5 11,5 14,5 15,0 16,0 17,0 18,0 19,0 21,0 21,5 22,5 24,5 65 80 95 125 155 220 250 280 315 365 395 460 500 575 675 11,3 9,8 8,9 8,3 7,4 6,6 6,2 5,9 5,6 5,3 5,2 4,9 4,7 4,5 4,3 35 35 40 45 45 60 60 65 65 70 75 85 85 90 100 Other size on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 22406 22407 22408 22409 22410 22411 22412 22413 22414 22415 22416 22417 22418 22419 22420 Number of conductors & cross-section n x mm2 250V CABLES LKM-FRHF 250V 250V CABLES 68 LKSM-FRHF DESIGN: Fire-resistant armoured control and instrumentation cable 250V STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic EC 60092-360 5/2016 3. Bedding - separator tape 4. Armour - drain wire copper (in all sizes) - copper wire braid, coverage > 90% - tinned copper wire braid on request IEC 60092-350 Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) 5. Sheath - polyolefine plastic, SHF1, standard colour orange IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: black numbers on white base Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 69 Part number 2x0,75 3x0,75 4x0,75 5x0,75 7x0,75 10x0,75 12x0,75 14x0,75 16x0,75 19x0,75 20x0,75 24x0,75 27x0,75 32x0,75 37x0,75 Other size on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Crosssection of armour mm2 3,1 3,9 4,3 4,8 5,3 6,9 7,2 7,6 11,1 11,7 12,6 14,0 14,3 14,9 16,2 Nominal outer diameter mm 9,0 9,5 10,5 11,5 12,5 15,5 16,0 16,5 18,0 19,0 20,0 22,0 22,5 23,5 25,5 Approximate weight kg/km 100 125 155 180 210 290 325 360 435 480 530 600 645 720 830 Current Rating A at +45°C Min. bending radius fixed installation mm 11,3 9,8 8,9 8,3 7,4 6,6 6,2 5,9 5,6 5,3 5,2 4,9 4,7 4,5 4,3 55 55 65 70 75 95 95 100 110 115 120 130 135 140 155 5/2016 22436 22437 22438 22439 22440 22441 22442 22443 22444 22445 22446 22447 22448 22449 22450 Number of conductors & cross-section n x mm2 250V CABLES LKSM-FRHF 250V 250V CABLES 70 LKAM-FRHF DESIGN: Fire-resistant screened control and instrumentation cable 250V STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 5/2016 2. Insulation - Mica tape - XLPE plastic IEC 60092-360 3. Screen - drain wire of tinned copper - aluminium polyester tape, coverage 100% IEC 60092-350 Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) 4. Sheath - polyolefine plastic, SHF1, standard colour orange IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request Application: For fixed installation in most areas and on open deck in ships and offshore units, especially when lightweight cables are needed.If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: black numbers on white base Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 71 Part number 2x0,75 3x0,75 4x0,75 5x0,75 7x0,75 10x0,75 12x0,75 14x0,75 16x0,75 19x0,75 20x0,75 24x0,75 27x0,75 32x0,75 37x0,75 Other size on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Nominal outer diameter mm 8,0 8,5 10,0 10,5 11,5 14,5 15,0 16,0 17,0 18,0 19,0 21,0 21,5 22,5 24,5 Approximate weight kg/km 70 85 110 135 160 225 255 295 330 370 400 465 510 600 680 Current Rating A at +45°C Min. bending radius fixed installation mm 11,3 9,8 8,9 8,3 7,4 6,6 6,2 5,9 5,6 5,3 5,2 4,9 4,7 4,5 4,3 50 50 60 65 70 90 90 95 100 105 115 125 130 135 145 5/2016 22466 22467 22468 22469 22470 22471 22472 22473 22474 22475 22476 22477 22478 22479 22480 Number of conductors & cross-section n x mm2 250V CABLES LKAM-FRHF 250V 250V CABLES 72 RFE-FRHF Fire-resistant armoured pair instrumentation and communication cable 250V 5/2016 DESIGN: STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic IEC 60092-360 3. Twisted pair - two insulated cores twisted together to form a pair See next page for Quad 4. Bedding - filler tape 5. Armour - drain wire (in all sizes) - copper wire braid, coverage > 94% IEC 60092-350 - tinned copper wire braid on request - the armour serves as a collective screen 6. Sheath - polyolefine plastic, SHF1, standard colour orange IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Fire-resistant Halogen-free Smoke emission IEC 60331-1 or IEC 60331-2 IEC 60754 series IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Electrical data Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C 0,75mm2 1,5mm2 52 24,4 45 55 0,6 0,7 ≥1500 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 73 Part number Nominal outer diameter mm 1x2x0,75 2x2x0,75 Quad 2x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 19x2x0,75 24x2x0,75 32x2x0,75 37x2x0,75 1x2x1,5 2x2x1,5 Quad 2x2x1,5 3x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 24x2x1,5 32x2x1,5 37x2x1,5 Other sizes on request. Core identification Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... (Quad)cable is built up as a star quad with the following identification 1 core white 2 core blue 3 core white 4 core blue 9,0 11,0 14,0 16,0 19,5 21,0 24,0 25,0 26,5 30,5 34,0 38,5 41,0 10,5 12,0 16,0 17,0 18,5 22,5 24,0 27,0 28,5 30,5 32,5 35,0 39,0 44,5 47,5 Approximate weight kg/km Min. bending radius fixed installation mm 115 170 200 285 445 495 615 685 765 970 1205 1520 1700 155 220 300 355 425 650 715 875 1000 1125 1280 1460 1795 2410 2730 55 65 85 95 115 125 145 150 160 180 205 230 245 65 70 95 100 110 135 145 160 170 180 195 210 235 270 285 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 20520 20522 20524 20526 20528 20530 20532 20534 20536 20538 20540 20542 20543 20575 20577 20579 20574 20581 20583 20585 20587 20589 20591 20593 20595 20597 20599 20601 Number of conductors & cross-section n x mm2 250V CABLES RFE-FRHF 250V 250V CABLES 74 RFE-FRHF (i) 5/2016 DESIGN: Armoured and individually screened instrumentation and communication cable 250V STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation Flame- Mica tape retardant - XLPE plastic IEC 60092-360 Fire3. Twisted pair & individual screen resistant - two insulated cores twisted together to form a pair Halogen- plastic coated aluminium tape and a tinned copper drain wire free 4. Bedding Low smoke - filler tape emission 5. Armour Oil resistant - drain wire copper (only SHF2) - copper wire braid, coverage > 94% IEC 60092-350 - tinned copper wire braid on request 6. Sheath - polyolefine plastic, SHF1, standard colour orange IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant Fire-resistant Halogen-free Smoke emission Oil resistance (only SHF2) 150/250V (300V) + 90 °C IEC 60332-1-2 IEC 60332-3-22 -test for single insulated wire and cable -test for bunched wires and cables, category A IEC 60331-1 or IEC 60331-2 IEC 60754 series IEC 61034 series IEC 60811-404 conditions according to 60092-360/SHF2 Electrical data Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C 0,75mm2 1,5mm2 52 24,4 55 75 0,6 0,7 ≥1500 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 75 Part number 2x2x0,75 2x2x0,75 Quad 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 19x2x0,75 24x2x0,75 32x2x0,75 1x2x1,5 2x2x1,5 Quad 2x2x1,5 4x2x1,5 7x2x1,5 1x2x1,5 2x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 Nominal outer diameter mm Approximate weight kg/km Min. bending radius fixed installation mm 14,0 11,0 16,5 20,0 21,0 24,5 25,5 27,0 31,0 35,0 39,5 10,5 12,0 16,0 19,0 22,5 10,5 16,0 19,0 22,5 24,0 27,5 29,0 31,0 33,0 35,5 215 170 345 495 545 675 770 865 1105 1370 1735 160 225 315 470 710 160 315 470 710 795 970 1130 1275 1430 1640 85 65 100 120 125 145 155 165 185 210 235 65 70 95 115 135 65 95 115 135 145 165 175 185 200 215 Other sizes on request. Core identification Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....) Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 20550 20548 20552 20554 20556 20558 20560 20562 20564 20566 20568 20603 20604 20605 20607 20609 20603 20605 20607 20609 20611 20613 20615 20617 20619 20621 Number of conductors & cross-section n x mm2 250V CABLES RFE-FRHF(i) 250V 250V CABLES 76 RFA-FRHF Fire-resistant screened pair instrumentation and communication cable 250V 5/2016 DESIGN: STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic IEC 60092-360 3. Twisted pair - two insulated cores twisted together to form a pair See next page for Quad 4. Collective screen - drain wire tinned copper - aluminium polyester tape, coverage 100% IEC 60092-350 5. Sheath - polyolefine plastic, SHF1, standard colour orange IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant 150/250V (300V) + 90 °C IEC 60332-1-2 IEC 60332-3-22 -test for single insulated wire and cable -test for bunched wires and cables, category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 For details see general information section Electrical data Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C 0,75mm2 1,5mm2 52 24,4 45 55 0,6 0,7 ≥1500 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 77 Part number Nominal outer diameter mm Approximate weight kg/km Min. bending radius fixed installation mm 8,0 9,5 13,0 15,0 18,0 19,5 22,5 23,5 25,5 27,0 29,0 32,5 9,0 14,5 14,5 15,5 17,0 20,5 22,5 26,0 27,0 29,0 31,0 33,5 37,5 39,5 42,0 43,0 46,0 70 105 135 210 315 355 435 500 590 655 770 950 95 185 190 245 310 485 560 695 800 925 1035 1230 1535 1695 1900 2005 2295 50 55 75 90 110 115 135 140 150 160 175 195 55 85 85 90 105 125 135 155 160 175 185 200 225 235 250 260 275 1x2x0,75 2x2x0,75 Quad 2x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 1x2x1,5 2x2x1,5 Quad 2x2x1,5 3x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 24x2x1,5 27x2x1,5 30x2x1,5 32x2x1,5 37x2x1,5 Other sizes on request. Core identification Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... (Quad)cable is built up as a star quad with the following identification 1 core white 2 core blue 3 core white 4 core blue Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 20635 20637 20639 20641 20643 20645 20647 20649 20651 20653 20655 20657 21521 21524 21525 21526 21527 21529 21531 21533 21535 21537 21539 21541 21542 21543 21544 21545 21547 Number of conductors & cross-section n x mm2 250V CABLES RFA-FRHF 250V 250V CABLES 78 RFA-FRHF (i) Collectively and individually screened instrumentation and communication cable 250 V 5/2016 DESIGN: STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic IEC 60092-360 3. Twisted pair & individual screen - two insulated cores twisted together to form a pair - plastic coated aluminium tape and a tinned copper drain wire 4. Bedding - separator tape 5. Collective screen - drain wire tinned copper - aluminium polyester tape coverage 100 % IEC 60092-350 6. Sheath - polyolefine plastic, SHF1, standard colour orange IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant 150/250V (300V) + 90 °C IEC 60332-1-2 IEC 60332-3-22 -test for single insulated wire and cable -test for bunched wires and cables, category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 For details see general information section Electrical data Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C 0,75mm2 1,5mm2 52 24,4 55 75 0,6 0,7 ≥1500 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 79 Part number 1x2x0,75 2x2x0,75 Quad 2x2x0,75 3x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 32x2x0,75 37x2x0,75 1x2x1,5 2x2x1,5 Quad 2x2x1,5 3x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 24x2x1,5 27x2x1,5 30x2x1,5 32x2x1,5 37x2x1,5 Nominal outer diameter mm Approximate weight kg/km Min. bending radius fixed installation mm 8,5 9,5 13,0 14,0 15,5 18,5 20,0 23,0 24,0 25,5 27,5 29,5 33,5 38,0 40,5 9,0 11,0 14,5 16,0 17,5 21,0 23,0 26,5 27,5 29,5 31,5 34,0 38,5 40,5 42,5 44,0 47,0 80 110 145 190 235 365 415 525 600 680 775 895 1135 1465 1680 105 170 210 280 345 545 635 800 920 1050 1205 1415 1785 1980 2190 2315 2675 50 55 80 85 90 110 120 140 145 155 165 175 200 230 245 55 65 90 95 105 125 135 160 165 175 190 205 230 245 255 265 280 Other sizes on request. Core identification Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....) Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2016 20664 20666 20667 20668 20669 20671 20673 20675 20677 20679 20681 20683 20685 20687 20689 21550 21552 21553 21554 21555 21557 21559 21561 21563 21565 21567 21569 21571 21572 21573 21574 21575 Number of conductors & cross-section n x mm2 250V CABLES RFA-FRHF(i) 250V 5/2016 LKSM-SHF2 120°C 0,6/1kV 80 LKSM-SHF2 120°C Heat and oil resistant armoured power and control cable 0,6/1kV DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,0-10mm2 IEC 60228, class 2 - stranded copper conductor 16-300mm2 IEC 60228, class 5 (Flex) - tinned stranded copper conductor on request 2. Insulation - improved heat resistant XLPE (+120°C) IEC 60092-360 3. Bedding - filler tape 4. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request 5. Sheath - improved heat resistant SHF2 (+120°C) IEC 60092-360 - standard colour black with grey stripes, other colours on request +120°C heat resistant Oil resistant Flameretardant Fireresistant Halogenfree Low smoke emission Application: For fixed installation in most areas and on open deck in ships or on oil rigs and various industrial use. Excellent resistance against weathering, ozone, UV-rays, Oil / Diesel oil. Typical Marine, Oil, Gas and Petrochemical applications are for example Ship Engine rooms, power plants and/or other areas where ambient temperature may exceed +80°C, which is the limit for traditional IEC 60092-cables. Rated voltage AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV) Oil resistance IEC 60811-404 conditions according to 60092-360 Halogen-free IEC 60754 series Flame-retardant IEC 60332-1-2 Test for single insulated wire and cable IEC 60332-3-22 Test for bunched wires and cables, category A Smoke emission IEC 61034 series Temperature rating: Fixed installation: -40ºC to +120ºC Occasionally moved: -20ºC to +120ºC Max. conductor temperature: +120ºC Core identification: See technical information section Sheath marking: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath The cable is marine type approved by all major classification societies. Cable name on type approval certificate is LKSM-SHF2. Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 81 Number of conductors & cross-section n x mm2 Crosssection of armour mm2 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 1x1,0 1x1,5 1x2,5 1x4 1x6 1x10 1x16 Flex 1x25 Flex 1x35 Flex 1x50 Flex 1x70 Flex 1x95 Flex 1x120 Flex 1x150 Flex 1x185 Flex 1x240 Flex 1x300 Flex 3,0 3,0 2,5 3,1 3,1 3,6 4,1 4,9 5,5 8,7 11,4 11,5 14,5 14,7 15,2 18,2 18,7 6,0 6,5 7,0 7,5 8,0 9,5 10,5 13,0 14,0 16,0 18,5 20,0 22,5 25,0 27,0 30,5 34,0 65 75 85 105 125 185 240 355 450 630 870 1085 1370 1685 2010 2645 3240 18 23 30 40 52 72 94 123 153 196 240 284 331 381 429 507 582 40 40 45 45 50 60 65 80 85 100 115 125 135 155 165 185 205 4125956 4125770 4125785 4125801 4125803 4125805 4126254 4126255 4126256 4126257 4126258 4126259 – – – – – – – – – – – – 2x1,0 2x1,5 2x2,5 2x4 2x6 2x10 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 2x70 Flex 2x95 Flex 3,6 3,8 4,3 5,2 5,4 8,7 10,0 14,5 14,7 18,1 18,7 22,2 9,0 9,5 10,5 12,0 13,0 15,5 18,0 23,0 24,5 28,5 33,0 36,5 105 125 155 205 305 465 610 955 1185 1605 2165 2745 15 20 26 34 44 61 80 105 130 167 204 241 55 60 65 75 80 95 110 140 150 175 200 220 4125957 4125772 4125786 4125802 4125804 4125806 4126271 4126273 4126275 4126277 4126279 4126281 4126283 4126285 4126287 4126289 – 4125773 4125787 4125880 4125882 4125884 4126272 4126274 4126276 4126278 4126280 4126282 4126284 4126286 4126288 4126290 3x1,0 3x1,5 3x2,5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 3x150 Flex 3x185 Flex 3x240 Flex 3,7 4,1 5,2 5,3 5,8 9,3 10,7 14,6 15,0 18,3 22,0 22,8 37,8 39,3 47,9 50,7 9,5 10,0 11,0 12,5 14,0 16,5 19,0 24,5 26,0 30,5 35,5 39,0 44,0 50,0 55,0 62,0 125 150 190 255 360 555 735 1140 1455 2015 2755 3495 4515 5620 6875 9005 13 16 21 28 36 50 66 86 107 137 168 199 232 267 300 355 60 65 70 80 85 100 115 150 160 185 215 235 265 305 335 375 G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Table continues on next page 5/2016 – 4128426 4127050 4127052 4127054 4127056 4127059 4127061 4127063 4127065 4127067 4127069 4127071 4127073 4127075 4127077 4127079 0,6/1kV 4125955 4125736 4125738 4125740 4125742 4125744 4126237 4126238 4126239 4126240 4126241 4126242 4126243 4126244 4126245 4126246 4126247 LKSM-SHF2 120°C LKSM-SHF2 120°C 0,6/1kV Part number Normal G-type 5/2016 LKSM-SHF2 120°C 0,6/1kV 82 LKSM-SHF2 120°C 0,6/1kV Part number Normal G-type Number of conductors & cross-section n x mm2 Crosssection of armour mm2 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 4125958 4125774 4125788 4125830 4125832 4125834 4126301 4126303 4126305 4126307 4126309 4126311 4126313 4126315 – 4125775 4125789 4125831 4125833 4125835 4126302 4126304 4126306 4126308 4126310 4126312 4126314 4126316 4x1,0 4x1,5 4x2,5 4x4 4x6 4x10 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 4x95 Flex 4x120 Flex 4x150 Flex 4,1 4,5 5,3 5,7 8,8 10,3 11,9 14,8 18,1 19,5 22,6 37,8 39,3 48,2 10,0 11,0 12,5 13,5 15,5 18,0 21,5 27,0 29,0 34,0 39,0 44,0 49,0 55,5 145 175 235 310 465 680 930 1415 1850 2540 3490 4625 5750 7265 13 16 21 28 36 50 66 86 107 137 168 199 232 267 65 70 75 85 95 110 130 165 175 205 235 265 295 335 4125959 4125776 4125790 4126011 4126013 4126015 4126331 4126333 – 4125777 4125791 4126012 4126014 4126016 4126332 4126334 5x1,0 5x1,5 5x2,5 5x4 5x6 5x10 5x16 Flex 5x25 Flex 4,5 5,0 5,6 8,6 9,7 11,5 13,2 18,1 10,5 12,0 13,5 15,0 17,0 20,0 23,0 29,5 170 215 280 400 550 815 1055 1635 10 13 17 23 30 42 55 71 65 75 80 95 105 120 140 180 4125960 4125961 4125962 4125963 4125964 4125965 4125977 4125978 4125981 – – – – – – – – – 7x1,0 10x1,0 12x1,0 14x1,0 16x1,0 19x1,0 24x1,0 27x1,0 37x1,0 4,9 8,7 9,0 9,4 10,0 10,6 12,5 12,8 14,4 11,5 15,0 15,0 16,0 17,0 17,5 20,5 21,0 23,5 210 310 340 375 435 480 595 645 825 9 8 8 7 7 7 6 6 5 75 90 95 100 105 110 125 130 145 4125778 4126025 4125780 4126027 4126030 4125782 4125828 4125783 4125784 4125779 4126026 4125846 4126028 4126029 4125781 4125829 4125847 4125848 7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 37x1,5 5,4 9,6 10,0 10,5 11,1 11,7 13,9 14,1 16,0 13,0 16,5 17,0 18,0 19,0 19,5 23,5 24,0 26,5 260 385 430 490 535 600 765 830 1065 12 11 10 10 9 9 8 8 7 80 100 105 110 115 120 140 145 160 4125792 4126033 4125794 4126035 4126037 4125796 4125798 4125768 4125793 4126034 4125795 4126036 4126038 4125797 4125799 4125769 7x2,5 12x2,5 10x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 8,5 10,8 11,5 11,8 12,5 13,2 15,7 16,1 15,0 18,5 19,0 20,5 21,5 22,5 26,0 27,0 375 525 580 670 745 840 1065 1160 16 14 13 13 12 11 10 10 90 115 115 125 130 135 160 165 Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G16 83 LKSM-SHF2 120°C 0,6/1kV 5/2016 LKSM-SHF2 120°C 250V 84 LKSM-SHF2 120°C, 250V Heat and oil resistant armoured control and instrumentation cable DESIGN: STANDARDS: IEC 60092-376, design 5/2016 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - improved heat resistant XLPE (+120°C) IEC 60092-360 3. Bedding - filler tape 4. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request 5. Sheath - improved heat resistant SHF2 (+120°C) IEC 60092-360 - standard colour black with grey stripes, other colours on request +120°C heat resistant Oil resistant Flameretardant Fireresistant Halogenfree Low smoke emission Application: For fixed installation in most areas and on open deck in ships or on oil rigs and various industrial use. Excellent resistance against weathering, ozone, UV-rays, Oil / Diesel oil. Typical Marine, Oil, Gas and Petrochemical applications are for example Ship Engine rooms, power plants and/or other areas where ambient temperature may exceed +80°C, which is the limit for traditional IEC 60092-cables. Rated voltage 150/250V (300V) Oil resistance IEC 60811-404 conditions according to 60092-360 Halogen-free IEC 60754 series Flame-retardant IEC 60332-1-2 Test for single insulated wire and cable IEC 60332-3-22 Test for bunched wires and cables, category A Smoke emission IEC 61034 series Temperature rating: Fixed installation: -40ºC to +120ºC Occasionally moved: -20ºC to +120ºC Max. conductor temperature: +120ºC Core identification: See technical information section Sheath marking: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath The cable is marine type approved by all major classification societies. Cable name on type approval certificate is LKSM-SHF2 250V. Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 85 Nominal outer diameter mm 6,5 7,0 7,5 8,0 8,5 10,5 10,5 11,0 11,5 12,5 13,0 14,0 14,5 15,0 16,0 7,5 7,5 8,0 9,5 10,0 12,0 12,5 13,0 13,5 14,5 18,0 17,0 17,5 18,0 19,5 Approximate weight kg/km 70 80 85 95 110 155 170 190 210 235 250 285 305 370 415 80 95 105 130 155 210 230 255 280 315 430 415 450 510 570 Current Rating A at +45°C Min. bending radius fixed installation mm 8,7 7,6 6,9 6,4 5,8 5,1 4,8 4,6 4,4 4,1 4,1 3,8 3,7 3,5 3,3 11,3 9,8 8,9 8,3 7,4 6,6 6,2 5,9 5,6 5,3 5,2 4,9 4,7 4,5 4,3 40 40 45 45 50 60 65 65 70 75 80 85 85 90 95 45 45 50 55 60 75 75 80 80 85 105 100 105 110 115 5/2016 2x0,5 3x0,5 4x0,5 5x0,5 7x0,5 10x0,5 12x0,5 14x0,5 16x0,5 19x0,5 20x0,5 24x0,5 27x0,5 32x0,5 37x0,5 2x0,75 3x0,75 4x0,75 5x0,75 7x0,75 10x0,75 12x0,75 14x0,75 16x0,75 19x0,75 20x0,75 24x0,75 27x0,75 32x0,75 37x0,75 Crosssection of armour mm2 3,0 3,0 2,6 3,1 3,2 4,1 4,3 4,5 5,3 5,1 5,5 6,1 6,3 8,9 9,7 3,1 3,1 3,2 3,6 3,9 5,1 5,3 5,6 5,9 6,3 10,9 10,2 10,5 10,9 11,8 250V Other sizes on request. Number of conductors & cross-section n x mm2 LKSM-SHF2 120°C LKSM-SHF2 120°C 250V Part number Normal 4127779 4127780 4127781 4127782 4127783 4127784 4127785 4127786 4127787 4127788 4127789 4127790 4127791 4127792 4127793 4126402 4126403 4126404 4126405 4126407 4126410 4126412 4126414 4126416 4126419 4126420 4126424 4126427 4126432 4126437 5/2016 RFE-SHF2 120°C 250V 86 RFE-SHF2 120°C Heat and oil resistant armoured pair instrumentation and communication cable DESIGN: STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - improved heat resistant XLPE (+120°C) IEC 60092-360 3. Twisted pair - two insulated cores twisted together to form a pair See next page for Quad 4. Bedding - filler tape 5. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request - the armour serves as a collective screen 6. Sheath - improved heat resistant SHF2 (+120°C) IEC 60092-360 - standard colour black with grey stripes, other colours on request +120°C heat resistant Oil resistant Flameretardant Fireresistant Halogenfree Low smoke emission Application: For fixed installation in most areas and on open deck in ships or on oil rigs and various industrial use. Excellent resistance against weathering, ozone, UV-rays, Oil / Diesel oil. Typical Marine, Oil, Gas and Petrochemical applications are for example Ship Engine rooms, power plants and/or other areas where ambient temperature may exceed +80°C, which is the limit for traditional IEC 60092-cables. Rated voltage 150/250V (300V) Oil resistance IEC 60811-404 conditions according to 60092-360 Halogen-free IEC 60754 series Flame-retardant IEC 60332-1-2 Test for single insulated wire and cable IEC 60332-3-22 Test for bunched wires and cables, category A Smoke emission IEC 61034 series Temperature rating: Fixed installation: -40ºC to +120ºC Occasionally moved: -20ºC to +120ºC Max. conductor temperature: +120ºC Electrical data: Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C 0,5mm2 0,75mm2 80 52 55 50 0,6 0,6 ≥1500 ≥1500 1,5mm2 24,4 60 0,7 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 87 Approximate weight kg/km Min. bending radius fixed installation mm 1x2x0,5 1x4x0,5 2x2x0,5 4x2x0,5 7x2x0,5 8x2x0,5 10x2x0,5 12x2x0,5 14x2x0,5 16x2x0,5 19x2x0,5 24x2x0,5 1x2x0,75 1x4x0,75 2x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 32x2x0,75 1x2x1,5 1x4x1,5 2x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 19x2x1,5 24x2x1,5 32x2x1,5 6,5 7,5 9,5 10,5 12,5 13,5 15,5 16,0 17,0 18,0 19,0 21,5 7,5 8,5 11,0 12,5 15,0 16,0 18,0 19,0 20,0 21,5 23,0 25,5 29,0 10,0 10,5 14,5 17,0 20,0 21,5 24,5 26,0 27,5 31,5 35,0 40,0 80 95 115 150 215 235 310 340 395 425 480 585 90 120 145 200 315 345 415 465 535 585 675 815 1040 135 185 230 370 540 620 750 850 955 1230 1525 1945 40 45 55 65 75 80 90 95 100 110 115 130 45 50 65 75 90 95 110 115 120 130 140 155 175 60 65 85 100 120 130 150 155 165 190 210 240 Other sizes on request. Core identification: See technical information section Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... (Quad)cable is built up as a star quad with the following identification 1 core 2 core 3 core 4 core white blue white blue Sheath marking: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath The cable is marine type approved by all major classification societies. Cable name on type approval certificate is RFE-SHF2. 5/2016 4120362 4120364 4120363 4120366 4120368 4120369 4120370 4120371 4120372 4120373 4120374 4120376 4120382 4120384 4120383 4120386 4120388 4120389 4120390 4120391 4120392 4120393 4120394 4120396 4120398 4120490 4120491 4120492 4120493 4120494 4120495 4120496 4120497 4120498 4120499 4120500 4120501 Nominal outer diameter mm 250V Part number Number of conductors & cross-section n x mm2 RFE-SHF2 120°C RFE-SHF2 120°C 250V RFE-SHF2 (i) 120°C 250V 88 RFE-SHF2 (i) 120°C Armoured and individually screened instrumentation and communication cable 250V 5/2016 DESIGN: STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - improved heat resistant XLPE (+120°C) IEC 60092-360 3. Twisted pair & individual screen - two insulated cores twisted together to form a pair - plastic coated aluminium tape and a tinned copper drain wire 4. Bedding - filler tape 5. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request 6. Sheath - improved heat resistant SHF2 (+120°C) IEC 60092-360 - standard colour black with grey stripes, other colours on request +120°C heat resistant Oil resistant Flameretardant Fireresistant Halogenfree Low smoke emission Application: For fixed installation in most areas and on open deck in ships or on oil rigs and various industrial use. Excellent resistance against weathering, ozone, UV-rays, Oil / Diesel oil. Typical Marine, Oil, Gas and Petrochemical applications are for example Ship Engine rooms, power plants and/or other areas where ambient temperature may exceed +80°C, which is the limit for traditional IEC 60092-cables. Rated voltage 150/250V (300V) Oil resistance IEC 60811-404 conditions according to 60092-360 Halogen-free IEC 60754 series Flame-retardant IEC 60332-1-2 Test for single insulated wire and cable IEC 60332-3-22 Test for bunched wires and cables, category A Smoke emission IEC 61034 series Temperature rating: Fixed installation: -40ºC to +120ºC Occasionally moved: -20ºC to +120ºC Max. conductor temperature: +120ºC Electrical data: Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C 0,5mm2 0,75mm2 80 52 55 70 0,6 0,6 ≥1500 ≥1500 1,5mm2 24,4 90 0,7 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 89 Approximate weight kg/km Min. bending radius fixed installation mm 1x2x0,5 1x4x0,5 2x2x0,5 3x2x0,5 4x2x0,5 7x2x0,5 8x2x0,5 10x2x0,5 12x2x0,5 14x2x0,5 16x2x0,5 19x2x0,5 24x2x0,5 27x2x0,5 30x2x0,5 32x2x0,5 37x2x0,5 1x2x0,75 1x4x0,75 2x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 19x2x0,75 24x2x0,75 1x2x1,5 1x4x1,5 2x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 19x2x1,5 24x2x1,5 32x2x1,5 7,0 7,5 9,5 10,0 11,0 13,0 13,5 15,5 16,5 17,5 18,5 19,5 22,0 23,0 24,0 24,5 26,5 7,5 8,5 11,0 13,0 15,5 16,5 18,5 19,5 21,0 23,5 26,0 10,0 11,0 14,5 17,0 20,5 22,0 25,0 26,0 28,0 32,0 36,0 41,0 85 110 135 165 195 285 345 420 485 535 590 690 840 925 1005 1070 1205 90 135 160 225 355 400 495 555 620 790 985 145 170 200 250 405 605 690 840 955 1090 1425 1755 40 45 60 60 65 75 80 95 100 105 110 120 135 140 145 150 160 45 50 65 75 95 100 110 115 125 140 155 60 65 85 105 120 130 150 155 170 195 215 245 Other sizes on request. Core identification: See technical information section Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....) Sheath marking: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath The cable is marine type approved by all major classification societies. Cable name on type approval certificate is RFE-SHF2(i). 5/2016 4122338 4122342 4122344 4122346 4122348 4122350 4122352 4122354 4122356 4122358 4122360 4122362 4122364 4122366 4122368 4122370 4122372 4122006 4122008 4122010 4122012 4122014 4122016 4122018 4122020 4122022 4122024 4122026 4122050 4122049 4122052 4122054 4122056 4122058 4122060 4122062 4122064 4122066 4122068 4122070 Nominal outer diameter mm 250V Part number Number of conductors & cross-section n x mm2 RFE-SHF2 (i) 120°C RFE-SHF2(i) 120°C 250V OPTICAL FIBRE CABLE 90 FXMSU Optical fibre indoor/outdoor cable Cable construction: 1. Central element glass fibre, 1,5 mm 2. PP-slotted core, 6,0 mm 3. Optical fibres, 250 μm 4. Swellable tape 5. Rip cord Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) 5/2016 6. UV-protected and halogen free sheath - non-metallic - networks in marine applications - Fibres: 250 μm SM or MM fibres - 4 - 48 fibres Cable characteristics: Maximum pulling force Crush strength / 100 mm (plate) Crush strength / 25 mm (mandrel) Impact strength Sheath marking Minimum installation temperature Operating temperature range Longitudinal water tightness Flame-retardant Halogen-free Smoke emission 500 N EN 187000 method 501 4000 N EN 187000 method 504 650 N EN 187000 method 504 25 J EN 187000 method 505 Cable type, manufacturer's name, manufacturing number and time, length marking in meter -15 °C -45...+70 °C EN 187000 method 605B .. Slotted core cables have blue and red marker threads for the first and last slot respectively. IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60754 series IEC 61034 series For details see general information section Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 91 Part number FXMSU 1X4SML (L) FXMSU 1X6SML (L) FXMSU 2X6SML (L) FXMSU 4X6SML (L) FXMSU 1X4OM3L (L) FXMSU 2X4OM3L (L) FXMSU 3X4OM3L (L) FXMSU 4X6OM3L (L) FXMSU 1X4GKL (L) FXMSU 1X6GKL (L) FXMSU 2X4GKL (L) FXMSU 3X4GKL (L) FXMSU 4X4GKL (L) FXMSU 4X6GKL (L) FXMSU1X4SML+1X4GKL (L) FXMSU1X4SML+2X4GKL (L) FXMSU2X4SML+2X4GKL (L) FXMSU1X6SML+3X4GKL (L) FXMSU2X6SML+3X4GKL (L) FXMSU1X4SML+1X4OM3 (L) FXMSU1X4SML+2X4OM3L (L) FXMSU2X4SML+2X4OM3L (L) FXMSU1X6SML+3X4OM3L (L) FXMSU2X6SML+3X4OM3L (L) Other fiber combinations on request Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Diameter of slotted core, mm 6 Nominal Approximate Minimum bending radius outer weight, during final diameter, kg/km installation, installation, mm mm mm 9,4 75 140 100 5/2016 10001 10022 10024 10028 14384 14386 14388 14398 14404 14406 14408 14410 14412 14416 14420 14422 14424 14426 14428 14449 14450 14451 14454 14455 Cable and number of fibres OPTICAL FIBRE CABLE FXMSU OPTICAL FIBRE CABLE 92 FXMMS Optical fibre installation cable Cable construction: Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant 1. FRP central element 2 mm 2. PP-slotted core 3. Installation cable unit FMS 1 (2 mm) 4. Fire barrier tape 5. Rip cord (only SHF2) 5/2016 6. Halogen free sheath 1,5 mm - For tray installation - Fibres: 2–8 SM or MM fibres, 900 μm - Connectors can be mounted directly to the fibres Cable characteristics: Maximum pulling force Crush strength / 100 mm (plate) Crush strength / 25 mm (mandrel) Impact strength, R = 300 mm Sheath marking Minimum bending radius Nominal cable diameter Cable weight Minimum installation temperature Operating temperature range 1500 N EN 187000 method 501 4000 N EN 187000 method 504 750 N EN 187000 method 504 30 J EN 187000 method 505 Cable type, manufacturer's name, manufacturing number and time, length marking in meter 195 mm during installation, 130 mm in final bending 13.1 mm 142 kg/km -15 °C -45...+70 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series For details see general information section Cable and number of fibres FXMMS 2-4 Diameter of slotted core, mm 7,5 FXMMS 6-8 9,7 Nominal Approximate Minimum bending radius outer weight, during final diameter, kg/km installation, installation, mm mm mm 10,7 102 160 110 13,1 142 195 130 Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 93 Part number 10810 10812 10814 10816 13747 13748 13749 13750 13872 13874 13876 13878 Cable and number of fibres FXMMS 2SMT (2MM) FXMMS 4SMT (2MM) FXMMS 6SMT (2MM) FXMMS 8SMT (2MM) FXMMS 2GKT (2MM) FXMMS 4GKT (2MM) FXMMS 6GKT (2MM) FXMMS 8GKT (2MM) FXMMS 2OM3T (2MM) FXMMS 4OM3T (2MM) FXMMS 6OM3T (2MM) FXMMS 8OM3T (2MM) Nominal Approximate Minimum bending radius outer weight, during final diameter, kg/km installation, installation, mm mm mm 10,7 102 160 110 10,7 102 160 110 13,1 142 195 130 13,1 142 195 130 10,7 102 160 110 10,7 102 160 110 13,1 142 195 130 13,1 142 195 130 10,7 102 160 110 10,7 102 160 110 13,1 142 195 130 13,1 142 195 130 5/2016 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Diameter of slotted core, mm 7,5 7,5 9,7 9,7 7,5 7,5 9,7 9,7 7,5 7,5 9,7 9,7 OPTICAL FIBRE CABLE FXMMS OPTICAL FIBRE CABLE 94 Cabled optical fibres characteristics Fibre coating: L = 250 μm ± 10 μm T = 900 μm ± 50 μm Single mode fibre 10/125 μm Fibre type SML 250μm±10μm SMT 900μm±50μm 5/2016 Mode field diameter (MFD) Mode field eccentricity -Installation cables Cladding diameter - Installation cables Cladding ellipticity Fibre attenuation 1310 nm 1310 nm 1550 nm Zero dispersion range Dispersion coefficient - Dispersion at Cut-off wavelength - Installation cables Polarization mode dispersion Proof test Fibre identification Multi mode fibre SM / OS2 (ITU-T G.652.D) 1550 nm 50/125 μm 9,3 +/- 0,5 μm ≤ 1,0 μm ≤ 0,5 μm 125 +/- 2 μm 125 +/- 1 μm ≤2% ≤ 0,40 dB/km ≤ 0,25 dB/km 1300...1324 nm ≤ 0,093 ps/nm2/km ≤ 18 ps/nm/km ≤ 1260 nm 1180...1250 nm ≤ 0,5 ps/√km 1 % / 1 sec 6 colour system according to SFS 5648 OM3 Fibre type OM3L 250μm±10μm OM3T 900μm±50μm Core diameter Core ellipticity Core eccentricity Cladding diameter Cladding ellipticity Fibre attenuation 50 +/- 3 μm ≤6% ≤ 3 μm 125 +/- 2 μm ≤2% ≤ 2,7 dB/km ≤ 0,8 dB/km ≥ 1500 MHz x km (LED) ≥ 500 MHz x km (LED) ≥ 2000 MHz x km (Laser) 0,200 +/- 0,015 6 colour system according to SFS 5648 Bandwidth Numerical aperture, NA Fibre identification 850 nm 1300 nm 850 nm 1300 nm 850 nm Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 95 62,5/125 μm GK / OM1 GKL 250μm±10μm GKT 900μm±50μm Core diameter Core ellipticity Core eccentricity Cladding diameter Cladding ellipticity Fibre attenuation 62,5 +/- 3 μm ≤6% ≤ 3 μm 125 +/- 2 μm ≤2% ≤ 3,5 dB/km ≤ 1,0 dB/km ≥ 200 MHz x km ≥ 500 MHz x km 0,275 +/- 0,015 6 colour system according to SFS 5648 Bandwidth Numerical aperture, NA Fibre identification 850 nm 1300 nm 850 nm 1300 nm 5/2016 Fibre type OPTICAL FIBRE CABLE Multi mode fibre TECHNICAL INFORMATION 96 GENERAL INFORMATION Standard for materials: IEC 60092-360 will replace and withdraw 60092-359 and 60092-351. Halogen-free Halogen-free refers to the absence of halogens, such as chlorine and fluorine, and is determined on the basis of halogen content and the acidity of gases of a cable. Insulation material: The designation SHF1 stands for thermoplastic compound. This material is halogen-free, highly flame-retardant and has low smoke emission. The designation SHF2 stands for oil resistant thermosetting compound. This material is halogen-free, highly flameretardant and has low smoke emission. 4m 2.5 m Sheathing material: Test on bunched cables IEC 60332-3 Burning is allowed up to max. 2.5 meters from the burner within specified time. 3.5 m The following designations are used for insulation materials in this catalog. All materials are halogen-free. XLPE stands for cross-linked polyethylene compound. It has excellent mechanical and electrical characteristics. 5/2016 All Helkama cables comply with the most severe requirements of category A. 1m 2m IEC 60332-1 is the test for single insulated wire and cable. Test procedure and requirements according to the picture below. 50 mm Definition of terms: Oil resistance Sheathing material is oil resistant according to method IEC 60811-404 and requirements from IEC 60092-360/SHF2. The oil resistance is demonstrated by immersion in IRM902 oil for 24h at 100°C. Flame-retardant To be flame-retardant, the cables must withstand the test specified in IEC standard 60332-3 or IEC 60332-1. Flame-retardant cables do not propagate fire, and are self-extinguishing. 475 mm IEC 60754-1 determines the halogen content of the material. To meet the requirements as halogen-free the halogen content of the material may not exceed 0,5 % or 5 mg/g. IEC 60754-2 determines the degree of acidity of gases evolved during combustion. The limit values are 4,3 for pH and 10 mikroS for conductivity. Smoke emission Smoke emission refers to visibility in a fire. The greater the light transmittance, the better the visibility. When tested in accordance with IEC 61034-1 (test method) and IEC 61034-2 (test requirements) the smoke emission of a cable during fire must not exceed the following values. 550 600 mm mm 27m3 cube smoke chamber Min. 50 mm of the cable, measured from the upper support, must remain unburned after the specified time. Requirements: 60 % light transmittance Un IEC 60332-3 is the test for bunched wires and cables and has three categories A, B and C, defined by different limits for flammable material and burning times. Burning time describes how long the burner is directed towards the bunch of cables. The requirement for passing the test is that after the burner has been removed the cables must extinguish themselves. Burning may not occur more than 2.5 m from the burner as shown in the figure. Amount of burning material Burning time A 7 litres/m 40 min B 3,5 litres/m 40 min C 1,5 litres/m 20 min Category 3A Fire-resistant IEC 60331-1 Test method for fire with shock at a temperature of at least 830 °C for 90 minutes for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm. IEC 60331-2 Test method for fire with shock at a temperature of at least 830 °C for 90 minutes for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20 mm. 830 °C / 90 min gas burner 500 mm 110 mm 97 BENDING RADIUS Recommended minimum bending radius, ( R ) : Outer diameter (D) During installation Fixed installation R = 9x D R = 6x D Tolerance ±0,5mm ±1,0mm ±1,5mm < 25mm > 25mm < 25mm > 25mm RFE-HF RFE-HF(i) RFA-HF RFA-HF(i) RFE-FRHF RFE-FRHF(i) RFA-FRHF RFA-FRHF(i) LKSM-SHF2 120°C LKSM-SHF2 120°C RFE-SHF2 120°C RFE-SHF2 (i) 120°C Cable outer diameter, mm. 30,1 – 40 40,1 – 50 50,1 – 60 Tolerance ±2,0mm ±2,5mm ±3,0mm (according to HD 308 S2) 250V 0,6/1kV a b 1 3 5 7 9 11 2 4 6 8 10 12 Normal type 1-core BK 2-cores BN BU 3-cores BN BK 4-cores etc. 5-cores GY Y/G BU BN BU BN Y/G BN GY BK GY BK 1 3 Y/G BU GY BN BK 3 Y/G 4 6 5 4 250V LKSM-HF 7-cores and above 2-cores 1 G-type (with earth conductor) 2 2 2 7 6 1 5 Black numbers on white base 2 1 3 4 5 Black numbers on white base Last core yellow/green. Black numbers on white base BU = Blue, BN = Brown, BK = Black, GY = Grey, Y/G = Yellow/Green 3-cores 1 2 3 1,8/3kV LKSM-VFD 1-core BK 3-cores BN BK Black numbers on white base 4-cores to 37-cores GY Black numbers on white base 3-cores + 3-ground cores Y/G BN BK Y/G GY Y/G 5/2016 Cable outer diameter, mm. 1 – 10 10,1 – 20 20,1 – 30 CORE IDENTIFICATION Pair number 1 2 3 4 5 6 R = 6x D R = 9x D R = 4x D R = 6x D LKSM-HF LKSM-EMC RFE-EMC-FRHF RFE-EMC-FRHF(i) LKSM-VFD LKMSM-HF LKAM-HF LKM-FRHF LKMM-FRHF LKSM-FRHF LKMSM-FRHF LKAM-FRHF Radius (R) DIAMETER TOLERANCE During installation During installation Fixed installation Fixed installation TECHNICAL INFORMATION LKM-HF LKMM-HF LKEM-HF TECHNICAL INFORMATION 98 CURRENT RATING "Current rating (A) at an ambient temperature of 45°C according to the standard IEC 60092-352 0,6/1 kV +90°C marine cables." Current carrying capacities in continous service at maximum rated conductor temperature of +90°C. For class 2 conductor cables Size N 1 2 3 4 5 7 10 12 14 16 19 24 27 37 1 18 23 30 40 52 72 96 127 157 196 242 293 339 389 444 522 601 0,85 15 20 26 34 44 61 82 108 133 167 206 249 288 331 377 444 511 0,7 13 16 21 28 36 50 67 89 110 137 169 205 237 272 311 365 421 0,7 13 16 21 28 36 50 67 89 110 137 169 205 237 272 311 365 421 0,58 10 13 17 23 30 42 56 74 91 0,52 9 12 16 0,46 8 11 14 0,44 8 10 13 0,41 7 9 12 0,40 7 9 12 0,37 7 9 11 0,35 6 8 11 0,33 6 7 10 0,30 5 7 9 1 2 3 4 5 7 10 12 14 16 19 24 27 37 1,5mm2 2,5mm2 4mm2 6mm2 10mm2 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 120mm2 150mm2 185mm2 240mm2 300mm2 1 17 22 30 39 50 71 94 123 153 196 240 284 331 381 429 507 582 0,85 14 19 26 33 43 60 80 105 130 167 204 241 281 324 365 431 495 0,7 12 15 21 27 35 50 66 86 107 137 168 199 232 267 300 355 407 0,7 12 15 21 27 35 50 66 86 107 137 168 199 232 267 300 355 407 0,58 10 13 17 23 29 41 55 71 89 0,52 9 11 16 0,46 8 10 14 0,44 7 10 13 0,41 7 9 12 0,40 7 9 12 0,37 6 8 11 0,35 6 8 11 0,33 6 7 10 0,30 5 7 9 Ambient temperature Correction factor +35°C 1,10 Factor, n 5/2016 For continuous service. Continuous service for a cable is to be considered as a current-carrying service (with constant load) having a duration longer than three times the thermal time constant of the cable, i.e. longer than the critical duration(see short time duty). 1,0mm2 1,5mm2 2,5mm2 4mm2 6mm2 10mm2 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 120mm2 150mm2 185mm2 240mm2 300mm2 For class 5 conductor cables Size N Factor, n 1,0mm2 +40°C 1,05 +45°C 1,00 +50°C 0,94 +55°C 0,88 +60°C 0,82 +65°C 0,74 +70°C 0,64 +75°C 0,58 +80°C 0,47 99 SHORT CIRCUIT CURRENT Based on formula: Ik = 226 X S t X S t X In 234 + Tk 234 + Tb Formula 1: Ik = 146 Ik S t Tk = = = = Maximum permissible short circuit current. Cross-section of the conductor in mm2. Duration of the short circuit in s. Maximum rated conductor temperature, short circuit, °C Tb = Maximum rated conductor temperature, normal, °C Formula 1: For 0,6/1kV cable with XLPE or HF90 with maximum operating temperature of +90°C (Tb) and short circuit temperature of +250°C (Tk). Cross-section of the conductor in mm2 1,0 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 0,2 0,3 0,5 0,8 1,3 2,0 3,3 5,2 8,2 11,4 16,3 22,9 31,0 39,2 49,0 60,4 78,4 97,9 0,5 1 2 3 0,2 0,1 0,1 0,1 0,3 0,2 0,2 0,1 0,5 0,4 0,3 0,2 0,8 0,6 0,4 0,3 1,2 0,9 0,6 0,5 2,1 1,5 1,0 0,8 3,3 2,3 1,7 1,3 5,2 3,7 2,6 2,1 7,2 5,1 3,6 3,0 10,3 7,3 5,2 4,2 14,5 10,2 7,2 5,9 19,6 13,9 9,8 8,0 24,8 17,5 12,4 10,1 31,0 21,9 15,5 12,6 38,2 27,0 19,1 15,6 49,6 35,0 24,8 20,2 61,9 43,8 31,0 25,3 Short circuit current in kA 10 0,0 0,1 0,1 0,2 0,3 0,5 0,7 1,2 1,6 2,3 3,2 4,4 5,5 6,9 8,5 11,1 13,9 5/2016 SHORT CIRCUIT FACTOR Short Circuit Factor can be calculated by following formula: SHORT CIRCUIT FACTOR = Duration of the short circuit in s. TECHNICAL INFORMATION Maximum permissible short circuit current. 0,6/1 kV +90°C marine cables. SHORT CIRCUIT CURRENT CURRENT RATING TECHNICAL INFORMATION 100 SHORT TIME DUTY Short time duty according to the standard IEC 60092-352 0,6/1 kV +90°C marine cables. If a cable is intended to supply motor or equipment operating for periods of half an hour or one hour, its current rating given in table “current rating”, may be increased using the relevant correction factors given by formula: correction = factor 1,12 1-exp(-ts/T) ( ts = service time, min. T = Time constant, min.) T = 0,245 x d 1,35 5/2016 (d = Overall diameter of the cable, mm.) Overall diameter of the cable, mm. Service time, min. 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 Time Critical constant, duration, min. min. 30 60 T 3x T 1,058 1,058 1,058 1,058 1,058 1,058 1,058 1,059 1,059 1,061 1,126 1,255 1,403 1,554 1,705 1,058 1,058 1,058 1,058 1,058 1,058 1,058 1,058 1,058 1,058 1,066 1,105 1,173 1,254 1,341 0,245 0,625 1,08 1,59 2,15 2,75 3,39 4,06 4,76 5,48 14,0 24,2 35,6 48,2 61,6 0,735 1,87 3,24 4,78 6,46 8,26 10,2 12,2 14,3 16,5 41,9 72,5 107 145 185 Correction factor. Intermittent service Correction factor for intermittent service according to the standard IEC 60092-352 The correction factor given hereby has been roughly calculated for periods of 10 min, of which 4 min are with a constant load and 6 min without load. Intermittence period = 10min. Intermittence ratio = 40%. Fi= 1-exp(-10/T) 1-exp(-4/T) Overall diameter of the cable, mm. Correction factor. 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 1,000 1,001 1,012 1,042 1,083 1,127 1,170 1,208 1,242 1,273 1,433 1,490 1,518 1,534 1,544 101 VOLTAGE DROP Size 1.0mm2 1.5mm2 2.5mm2 4mm2 6mm2 10mm2 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 120mm2 150mm2 185mm2 240mm2 300mm2 Resistance at +20°C ohm/km Resistance at +90°C ohm/km Voltage reduction mV/Am *) Resistance at +45°C ohm/km Current rating A **) Voltage reduction mV/m ***) 18,1 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 23,1 15,4 9,45 5,88 3,93 2,33 1,47 0,927 0,668 0,493 0,342 0,246 0,195 0,158 0,1264 0,0961 0,0766 46,2 30,9 18,9 11,8 7,85 4,67 2,93 1,85 1,34 0,987 0,683 0,492 0,390 0,316 0,253 0,192 0,153 19,9 13,3 8,14 5,06 3,38 2,01 1,26 0,798 0,575 0,425 0,294 0,212 0,168 0,136 0,1088 0,0828 0,0660 18 23 30 40 52 72 96 127 157 196 242 293 339 389 444 522 601 0,72 0,61 0,49 0,41 0,35 0,29 0,24 0,20 0,18 0,17 0,14 0,12 0,11 0,11 0,097 0,086 0,079 Size 0,75mm2 1.0mm2 1.5mm2 2.5mm2 4mm2 6mm2 10mm2 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 120mm2 150mm2 185mm2 240mm2 300mm2 Resistance at +20°C ohm/km Resistance at +90°C ohm/km Voltage reduction mV/Am *) Resistance at +45°C ohm/km Current rating A **) Voltage reduction mV/m ***) 26,0 19,5 13,3 7,98 4,95 3,30 1,91 1,21 0,78 0,554 0,386 0,272 0,206 0,161 0,129 0,106 0,0801 0,0641 33,2 24,9 17,0 10,18 6,31 4,21 2,44 1,54 0,995 0,706 0,492 0,347 0,263 0,205 0,164 0,135 0,102 0,082 66,3 49,7 33,9 20,4 12,6 8,42 4,87 3,09 1,99 1,41 0,984 0,694 0,525 0,411 0,329 0,270 0,204 0,163 28,6 21,4 14,6 8,76 5,44 3,62 2,10 1,33 0,857 0,608 0,424 0,299 0,226 0,177 0,142 0,116 0,088 0,070 14 17 22 30 39 50 71 94 123 153 196 240 284 331 381 429 507 582 0,80 0,73 0,64 0,53 0,42 0,36 0,30 0,25 0,21 0,19 0,17 0,14 0,13 0,12 0,11 0,10 0,09 0,08 Cable types: LKSM-HF 250V, RFE-HF, RFE-HF(i), RFA-HF, RFA-HF(i), RFE-FRHF, RFE-FRHF(i), RFA-FRHF, RFA-FRHF(i) Size 0,5 mm2 0,75 mm2 1,5 mm2 Resistance at +20°C ohm/km Maximum conductor temperature, °C Resistance at +45°C ohm/km Voltage reduction mV/Am at +45°C Resistance at +90°C ohm/km Voltage reduction mV/Am at +90°C 40,4 26,0 12,8 90 90 90 44,4 28,6 14,1 88,7 57,1 28,1 51,5 33,2 16,3 103,0 66,3 32,6 *) at +90°C **) For continuous service (single core, ambient temperature +45°C) ***) at maximum current rating for continuous service at +45°C 5/2016 Cable types: LKM-HF FLEX, LKSM-HF FLEX, LKEM-HF (Cables with class 5 conductor) TECHNICAL INFORMATION Cable types: LKM-HF, LKSM-HF, LKAM-HF, LKM-FRHF, LKSM-FRHF (Cables with class 2 conductor) HELKAMA BICA OY Lakimiehenkatu 4 FI-20780 KAARINA Finland Tel. +358 2 410 8700 Fax +358 2 237 2428 firstname.lastname@helkamabica.fi sales@helkamabica.fi Helkama Bica (Shanghai) Co., Ltd. Plot 1-2, MinHang Export Processing Zone No. 3111 Huan Cheng West Road Fengxian District, Shanghai 201401, China Tel. +86 21 3365 5333, Fax +86 21 3365 5331 sales@helkamabica.cn www.helkamabica.com
Similar documents
ÖLfLEx® iNStrum SWA 280 h
the international market and is a Lapp Group Company. Lapp Group is a global supplier of cable technology well present worldwide with 41 own sales companies, 17 production plants and more than 100 ...
More informationMarine Cables
LSM-FRHF 0,6/1 (1,2) kV Armoured Fire Resistant Power and Control Cable
More informationINDUSTRIAL CABLES OPTICAL FIBRE CABLES
applied as a screen over the polyester tape. 7x0,30 tinned copper drain wire under the screen.
More information