09 / 03 / 2016 FROM: Safetmade Deniz İnşaat Yangın Malzemeleri
Transcription
09 / 03 / 2016 FROM: Safetmade Deniz İnşaat Yangın Malzemeleri
09 / 03 / 2016 FROM: Safetmade Deniz İnşaat Yangın Malzemeleri Makina Kimya Tekstil San. Ve Tic Ltd Şti TO: EUROPEAN COMISSION Directorate General For Mobility and Transport D2 CC: Ms Gündüz Permanent Delegation of Turkey to the EU CC: Ms Brandi Baldwin P.E Chief Lifesaving&Fire Safety Divison US Coast Guard HQ CC: Mr Volkan Çelik Manager, Turkey Plan Approval & Technical Support Center RINA Services SpA. (Istanbul) Subject: Defective hydrostatic release units recall actions; Dear Sir / Madam; After receiving your email on 12/02/2016 with Ref. Ares (2016)763845 concerning our hydrostatic release units, we felt the need to inform you that we had already been aware of the situation since the fourth quarter of year 2015 and taking the following recall actions. 1- We asked our distributors and sellers to stop sales activities of hydrostatic release units for life rafts (HRU LR-1) and for EPIRBs (HRU EP-1), collect the sold products from the market, gather the collected and ex-stock HRUs in their premises, cut HRU ropes or pins and take a photo of them immediately afterwards. Distributor/seller companies and the collected disposed units are indicated in the below table. No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Company Name Type/Brand GKY DIŞ TİC. LTD. ŞTİ. ASKOROS VIKING LIFE-SAVING EQUIPMENT Recalled Unit Quantity (HRU LR-1) 589 Recalled Unit Quantity (HRU EP-1) HYGRAPHA 2316 CANTAŞ DENİZCİLİK LTD. ŞTİ. SAFETMADE 432 675 63 SAFETMADE EUROPE BV SAFETMADE 1457 71 SAFETMADE 993 SAFETMADE 77 SAFETBAG DENİZ HİZM. LTD. ŞTİ. SAFETMADE SAFETBAG MIDDLE EAST FZC SAFETMADE TRIDENTE SRL SAFETMADE ANCIENT SEA PEARL GEDVEC SA EUROPEAN AGENCIES & MARITIME WORKS 192 48 SAFETMADE 476 SEASAFE SERVICE DESK SAFETMADE 774 ATN MARINE SAFETMADE 912 ODYSSEY SHIPSERVICE AS SAFETMADE 698 BOSSS LIFEBOAT AND LIFESAVING SERVICES SHANGHAI RUBBER STAR PRODUCTS CO. LTD. SAFETMADE SAFETMADE 584 SAFETMADE 146 BOLAT OAO SAFETMADE 457 SAFETMADE TOTAL AMOUNT 1 128 SENEGAL SECURITY SENSEC DOLPHIN MARINE 8 92 11046 143 Furthermore, the photos of the disposed units are in the ANNEX I. Upon request, we can share more disposed product photos from our archive with EU Commission. 2- We announced “Safetmade recall of hydrostatic release units” with a SAFETY ALERT on Safetbag website on the 14th of December, 2015 and with a VOLUNTARY RECALL MESSAGE on Vira Maritime News website on the 17th of December, 2015. 2.1- The SAFETY ALERT about HRU LR-1 & HRU EP-1 on our website was published on the 14th of December, 2015. - The regarding link of the alert is as follows. http://safetbag.com/2015/12/14/safety-alert-hru-lr-1-and-ep-1/ - The voluntary recall message on our website is also submitted for your reference herein below. SAFETY ALERT : HRU LR-1 and EP-1 Safetmade Marine Products Co. Issues a Voluntary Recall of Hydrostatic Release Units LR-1 & EP-1; due to possible corrosion risk Officially Released Message is as follows: FOR IMMEDIATE RELEASE: Safetmade Deniz İnşaat Yangın Malzemeleri Makina Kimya Tekstil San. Ve Tic Ltd Şti RECALL DETAILS In conjunction with: European Commission; Classification Societies DESCRIPTION This recall involves Hydrostatic Release Units (HRU) manufactured by SAFETMADE with model no LR-1 and EP-1 delivered to consumers for use on life rafts and EPIRBs; sold at retail locations such as ship chandlers, ship suppliers, life raft repair/service stations, EPIRB and radio communication service stations, and maritime equipment retailers. Possible malfunction risks are detected due to harsh sea conditions and high levels of salty water effect on the product that may result in corrosion inside the unit. INCIDENTS/INJURES None reported REMEDY REPLACE units in OPERATION (ASAP) and STOP SALES of units in stocks: Consumers should not try to open and inspect HRU themselves; they should immediately contact SAFETMADE Marine Products CO. to arrange a replacement at the nearest port. RECALL DEADLINE All units should be reported and replaced until 01.09.2016 18:00 EET Safetmade Marine Products Co. will not be held responsible for any possible incidents due to non-replaced HRU units after the mentioned above date. REPLACEMENT INSTRUCTIONS 1. Issue and send us a documentation that specifies the number of units they hold, their respective serial numbers, date purchased and date installed on the life raft or EPIRB. 2. According to the information and confirmation supplied by our side, proceed with replacing the units. 3. Remove the HRU from life raft or EPIRB. Disable units by cutting their ropes or breaking pins. Take photos of removed HRU units and send to: sales@safetbag.com 4. Removed units should be disposed as an expired NOTICE FOR DISTRIBUTORS AND SELLERS Distributors and sellers should immediately STOP sales, count the remaining units in their stocks, issue a document for their serial numbers and contact SAFETMADE Marine Products CO. CONTACT INFORMATION e-mail: sales@safetbag.com Office phone number: 0090 (232) 431 10 00 (MON-TUE-WED-THU-FRI, 08:30 – 17:30; SAT, 08:30 – 11:30. Eastern European Time Zone UTC + 02:00) Website: www.safetbag.com SOLD AT Distributed worldwide, delivered by companies under following brands; -SAFETMADE -ASKOROS (OEM) MANUFACTURER(S) SAFETMADE MARINE PRODUCTS CO. of Turkey MANUFACTURED IN Izmir, TURKEY PRODUCT PHOTOS 2.2- The VOLUNTARY RECALL MESSAGE about HRU LR-1 & HRU EP-1 at www.virahaber.com was published on the 17th of December, 2015. It is demonstrated in a circle below. - The regarding link of the message is as follows. http://www.virahaber.com/vira-maritime/safetmade-recall-of-hydrostatic-release-unitsh39156.html - The voluntary recall message on VIRA HABER is also submitted for your reference herein below. Safetmade recall of hydrostatic release units Safetmade, Issues a Voluntary Recall of Hydrostatic Release Units LR-1 & EP-1; due to possible corrosion risk. This recall involves Hydrostatic Release Units (HRU) manufactured by SAFETMADE with model no LR-1 and EP-1 delivered to consumers for use on life rafts and EPIRBs; sold at retail locations such as ship chandlers, ship suppliers, life raft repair/service stations, EPIRB and radio communication service stations, and maritime equipment retailers. Possible malfunction risks are detected due to harsh sea conditions and high levels of salty water effect on the product that may result in corrosion inside the unit. Replace units in operations (ASAP) and stop sales of units in stocks: Consumers should not try to open and inspect HRU themselves; they should immediately contact SAFETMADE Marine Products CO. to arrange a replacement at the nearest port. All units should be reported and replaced until 01.09.2016 18:00 GMT Safetmade Marine Products Co. will not be held responsible for any possible incidents due to non-replaced HRU units after the mentioned above date. 1 Issue and send us a documentation that specifies the number of units they hold, their respective serial numbers, date purchased and date installed on the life raft or EPIRB. 2 According to the information and confirmation supplied by our side, proceed with replacing the units. 3 Remove the HRU from liferaft or EPIRB. Disable units by cutting their ropes or breaking pins . Take photos of removed HRU units and send to: sales@safetbag.com 4 Removed units should be disposed as an expired Distributors and sellers should immediately stop sales, count the remaining units in their stocks, issue a document for their serial numbers and contact SAFETMADE Marine Products CO. ViraMaritime ANNEX I THE PHOTOS OF DISPOSED HRU LR-1 & HRU EP-1