Overfill - Littlejohn, Inc.
Transcription
Overfill - Littlejohn, Inc.
ROMLink™ “Plug-N-Load” System Rev. A, May 2009 Section A Petroleum Trailer Parts Civacon Civacon’s retrofit kit, is a link to a fast installation and worry free future. The ROMLink™ gives you a hassle free installation which allows you to “Plug-N-Load”. The Civacon ROMLink™ “PLUG-N-LOAD” System represents a major revolution in the Overfill Detection World. Since the introduction of overfill electronics on petroleum and other product hauling tankers, OEM’s, Installers, Repair Shops and End Users have been frustrated by the way in which electronics and other components are connected together in the system. Unless the crimps are installed with absolute precision, the longevity of the system is compromised. In the desire to eliminate this frustrating cycle, Civacon has developed the ROMLink™ “PLUGN-LOAD” System. This system not only improves trouble points, but eliminates them. Before After Features and Benefits • • • • • • Crimp Free Installation No Special Tools or Training Required Fits All Compartment Layout Configurations Can be added to existing trucks with overfill systems Completely Sealed harness system that will last in any environment Components color coded for easy identification PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com 177 Section A Petroleum Trailer Parts Civacon 3100 5-wire monitor ROMBolt II Monitor Model GS1000 – SAF-T3202 Ground Kit The Civacon Model GS1000 SAF-T Ground Bolt Kit offers the safety, compatibility and value you expect. The Civacon Model GS1000 SAF-T Ground Bolt Kit includes our Ground Verification Bolt for use on Tankers that load at Terminals where the Loading Rack Monitor requires a special modified signal as part of their ground verification operation. The Civacon Model GS1000 SAF-T Ground Bolt is a direct replacement of other similar Ground Bolts, and fully compatible with all Loading Rack Monitors that require this type of device. For proper operation, it MUST be securely fastened to the tanker chassis, and wired to Pin No. 9 of the Overfill Detection Sockets) to provide proper ground verification. 4100 Thermistor socket 4400 Optic socket 178 The Civacon Model GS1000 SAF-T Ground Bolt Kit comes with all of the hardware needed to provide a secure, trouble-free installation on any tanker configuration. 4820 Dual socket assy GS1000 Grounding bolt Features and Benefits • Strong, Stainless Steel Construction. • Long, 5-1/2 foot (165cm) Wire. • Two Internal-Tooth Stainless Steel Lockwashers. • Corrosion-resistant Strain Relief Fitting. • Two Electrical Terminals to fit all Socket Styles. • Sturdy Round Label to identify the Ground Bolt and cover and protect area around it. Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com Ordering Specifications GS1000 SAF-T Ground Bolt Kit Three Wire OCS System Section A Petroleum Trailer Parts EBW Three Wire OCS System All OCS Control Modules perform continuous self-testing of all probes for a dry condition, wet condition, or faulted condition. All OCS Control Modules perform continuous selftesting of the wiring between the probes and controllers. All OCS Control Modules continuously test for broken wires, shorted ground wires, shorted power wires, and shorted signal wires. All OCS Control Modules monitor for the proper input signal and proper input voltage from the rack monitor. OCS Control Module will allow permit to load only after proper signals are received from the rack monitor. Features and Benefits • Micro-Processor Base Controller • Monitors external inputs • Internal relay outputs • Waterproof housing with clear viewing lens • FM Approved for Hazardous (Classified) Locations. • Continuous Self Testing of • All Probes Attached • All Probe and Power Wiring • Rack Input Signals for Terminal • Proper Input Voltage Part No. 890-401-03 890-201-03 Description Controller mounted in Waterproof Housing Control Module Only Three Wire OCS Optic Probes EBW Transport Systems dedication and commitment to customer satisfaction and service will be equaled to none when it comes to making sure their customers are the most satisfied in the World. EBW Transport Systems stands ready to raise the bar when it comes to customer service and EBW Transport Systems will make sure this dedication and commitment reaches beyond the normal service calls and inquiries. Features and Benefits • Probes feature surface mount military spec electronic components • Probes are compatible with all existing EBW Controllers • Operating Temperature -40 degF - +160 degF • Three-Wire Probes - OCS System Compatible • FM Approved for Hazardous (Classified) Locations Part No. 890-111-01 890-111-02 890-111-03 6 Description OCS Optic Overfill Probe 7.40 inch OCS Optic Overfill Probe 11.69 inch OCS Optic Overfill Probe 15.69 inch Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com 179 Section A Petroleum Trailer Parts EBW Three Wire System EBW Transport Systems commitment to quality does not stop at the loading rack or at the service station. EBW Transport Systems commitment to quality is with you and your equipment twenty-four hours a day. Features and Benefits • Probes are compatible with all existing EBW Controllers • Operating Temperature -40 degF - +160 degF • Optical Sensor for quickest and most reliable product sensing • Three-Wire Probes - OCS System Compatible • FM Approved for Hazardous (Classified) Locations Part No. 890-111-04 Description Three wire Optic Overfill Probe w/Flange 6.25 inch Three Wire System EBW Transport Systems has spared no expense during the development and testing of the OCS Optic Overfill and Optic Retained Product probes. EBW Transport Systems is dedicated to providing the highest quality overfill protection solutions available in the World. These probes and controllers are rivaled by no one in the industry. Features and Benefits • Probes feature surface mount military spec electronic components • Operating Temperature -40 degF - +160 degF • Three-Wire Probes - OCS System Compatible • FM Approved for Hazardous (Classified) Locations Part No. 890-121-A 890-121-01 All OCS Optic Probes are FM approved for Hazardous (Classified) Locations. FMRC Class No. 3600 Electrical Equipment for Use in Hazardous (Classified) Locations General Requirements. FMRC Class No. 3610 - Intrinsically Safe Apparatus for Use in Class 1, II and III Division 1 Hazardous (Classified) Locations. FMRC Class No. 3611 - Electrical Equipment for Use in Class I, 7 180 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com Description Three Wire Retained Product Probe w/Coupling Three Wire Optic Retained Product Probe Only Division 2, Class II, Division 2 and Class III, Division 1 and 2 Hazardous Locations. Probe Holders Advantages 908-262-01 908-263-01 Anodized aluminum construction. 1/2" NPT connection ports. 2" NPT male thread. 2" NPT cast lock nut. Tall or short cover. O-ring sealed. Three bolt locking ring. For use with all EBW and competition probes. Section A Petroleum Trailer Parts • • • • • • • • Probe kits are available with Two-Wire Probes or Three-Wire Probes. Kits are standard with the 908-263-01 probe holder with a cast lock nut. Two styles are available: a Three-Wire Optic Probe (890-257-01) or a Two-Wire Optic Probe (890-257-02).EBW 908-208-01 890-257-02 TRANSPORT Two-Wire Probe SYSTEMS Optic Control System Single Socket Solutions Part Number Description 890-257-02 Probe Holder with Two-Wire Probe 908-262-01 • Ease of installation. Probe Holder with 2" Male NPT Thread 908-262-02 • Moisture proof. Probe Holder with 2" Male NPT Thread, Tall Cap These sockets are moisture proof and have stainless steel contact pins overfill monitor plugs. Advantages Single Sockets are manufactured in accordance to API RP1004 and are compatible with all in Lock a bakelite • Stainless steel contact pins. 908-263-01 Probe Holder with 2" Cast Nut housing. Hard-coated aluminum faceplates and J-Slots are long-lasting and come standard with black plastic caps. Optic, Thermistor and Float styles are available. • Produced in accordance with 908-208-01 Tall Probe Holder Cover API 1004. • Available in all three API standard socket configurations. 908-221-01 908-230-01 908-211-01 54 Part Number Description 908-211-01 Thermistor Socket with Plastic Cap 908-221-01 Optic Socket with Plastic Cap 908-230-01 7-Pin Socket with Plastic Cap 908-119-01 Plastic Cap Only 908-110-01 Thermistor Conversion Kit 908-120-01 Optic Conversion Kit 908-231-01 7-Pin Conversion Kit Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com 181 Section A Petroleum Trailer Parts Scully 08687 5-wire monitor 09109 Intellicheck II monitor 08560 Ground bolt 08274 Ground ball 67151 SJ-8Bs 12.21.1999 12:41 PM Page 1 08836 TIM chip Scully Thermistor Socket Overfill Prevention For Road Tankers with 1-8 Compartments 67151 SJ-8Bs 12.21.1999 12:41 PM Page 1 Description 07720 - Thermistor socket The Scully Thermistor socket is used to 07974 - Optic socket connect up to 8 tanker mounted thermistor sensors to the Scully Biclops® III Overfill Prevention Monitor via the Scully Sculcon® Plug and Cable Unit. Scully Thermistor Socket Overfill Prevention For Road Tankers with 1-8 Compartments Description • Lightweight polyvinyl cap is included Scully Thermistor Socket with Polyvinyl Cap • Use with Scully thermistor sensors The Scully Thermistor is used • Available with integral brakesocket interlock switchto connect up to 8 tanker mounted thermistor for top loading • Rugged construction • Pins for tanker earthing incorporated • Incorporates electronic dummy for tankers with less than eight compartments • Easy installation on tanker chassis • Accomadates top and bottom loading Scully Thermistor Socket with Polyvinyl Cap 182 sensors to the Scully Biclops® III Overfill Prevention Monitor via the Scully Sculcon® • Optional mounting bracket with threaded Plug and Cable Unit. captive plate and bolts for top loading socket • Optional integral pressure switch for vapor recovery • Lightweight polyvinyl cap is included Emergency Shutdown Principle of Overfill Prevention • Available integral brake interlock switch Systemwith Components Spartanburg, SC Phone: 800.828.6555 Fax: 864.583.1550 • Use with Scully thermistor sensors for top loading Scully Scully Sensor Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Control Main Power • Rugged construction • Pins for tanker earthing incorporated Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 Monitor • Incorporates electronic dummy for tankers with • Optional mounting bracket with threaded www.littlejohninc.com Scully less than eight compartments Tanker • Easy installation on tanker chassis • Accomadates top and bottom loading Junction plate and Output captive bolts for top Terminal loading socket Signal Automation Scully Box System • Optional integral pressure switch for Socket & Plug Connection Cable vapor recovery 09209 5-wire probe 09409 2-wire probe FT103 CheckMate monitor Section A Petroleum Trailer Parts FloTech FT208 5-wire monitor FT100 5-wire probe FT150 2-wire blk/wht FT201 2-wire blk/red Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com 183 Section A Petroleum Trailer Parts Civacon Model #3100 Liberty On Board Monitor for use with 5-Wire Optic Sensors Replacement Par t s Rev. A, March 2006 8 7 3 5 2 1 9 4 6 10 ITEM 1 2 3 4 5 6 7 8 9 10 184 PART NUMBER C40015M C40097M C40104A 3150-3150 C40180M D40006A H50086M H50114M H50623M-2 H50070M DESCRIPTION GASKET (ENCLOSURE, OBM) WINDOW (ENCLOSURE, OBM) COVER (ENCLOSURE, OBM) ASSEMBLY MODULE (OPTIC OBM) NAME PLATE (3100 MONITOR) BASE (ENCLOSURE, OBM) WASHER (1/4" SPLIT, S.S.) SCREW (1/4-20 X 3/4, S.S.) SCREW (#6-32 X 3/8 S.S. W/LOCK WASHER) PIPE PLUG (1/2" N.P.T.) Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com QTY. 1 1 1 1 1 1 6 6 4 1 PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com Section A Petroleum Trailer Parts Civacon Model #3202 ROM II On Board Monitor for use with Civacon 2-Wire Optic Sensors Replacement Par t s Rev. 0, January 2003 8 7 3 2 1 9 12 4 5 6 11 ITEM 1 2 3 4 5 6 7 8 9 10 11 12 10 PART NUMBER C40015M C51426M C40104APC 3252 H51425M D40006APC H50086M H50114M H50623M-2 H50452 H50070M H51642M DESCRIPTION GASKET (ENCLOSURE, OBM) WINDOW (ENCLOSURE, OBM) COVER (ENCLOSURE, OBM, GRAY POWDERCOATED) ASSEMBLY MODULE (OPTIC OBM) NAME PLATE (APPROVALS, ROM II) BASE (ENCLOSURE, OBM, GRAY POWDERCOATED) WASHER (1/4" SPLIT, S.S.) SCREW (1/4-20 X 3/4, S.S.) SCREW (#6-32 X 3/8 S.S. W/LOCK WASHER) SWITCH ASSEMBLY (1/2" N.P.T.) PIPE PLUG (1/2" N.P.T.) JUMPER STRIP (10 POSITION) QTY. 1 1 1 1 1 1 6 6 4 1 1 1 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 PHONE: (816) 741-6600 • (888) 526-5657 • Fax:OH (816) 741-1061 Cincinnati, - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, - Phone: 800.621.7131 - Fax: 708.442.9229 4304 Mattox Road • Kansas City, MO 64150 •ILwww.civacon.com www.littlejohninc.com 185 Section A Petroleum Trailer Parts Civacon PARTS BREAK DOWN 4100-4100 Optic Socket API Pattern for Optic Output ITEM PART NUMBER 1 C40011M2 2 D40103AH DESCRIPTION CONTACT BLOCK 2 FACEPLATE, OPTIC QTY. ITEM PART NUMBER 1 13 C51503M2 14 2 1 H50618M 1,2 DESCRIPTION QTY. LABEL, TECH ASSISTANCE 1 GROUND WIRE 1 DUST CAP, BLUE 1 CABLE 1 3 D40100A BODY 1 15 H50025M 4 H50616M2 CONTACT, BUTTON 6 16 H50288M1,2 5 H50064M 2 GASKET 1 17 H50290M 1,2 RIVET 1 6 H50617M2 INSERT 4 18 H50292M1,2 WASHER 1 7 H50074M2 SCREW, #6-32 1/2” 1 19 H50293M1,2 LOGO WASHER 1 SCREW, #6-32 3/8” 1 NAME PLATE 1 8 H50623M-2 9 H50107M2 2 10 H50108M 11 H50250M2 12 2 H50291M 2 SCREW, 5/16-18 3/4” 2 WASHER, 5/16 SS 2 4150-4150 REPAIR KITS DUST CAP SPACER 1 4110-4110 FACE PLATE KIT 1 - Included in 4150-4150, 2 - Included in 4110-4110 PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com 186 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com Rev. +, July 2009 Section A Petroleum Trailer Parts Civacon Model #4401 Socket API pattern for thermistor output Replacement Par t s Rev. A, March 2006 1 10 11 12 8 2 9 6 4 7 13 14 5 3 ITEM PART NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 N/A 4450 C40011M D40100A D40102AH H50064M H50074M H50136M H50108M H50250M H50291M H50616M H50617M H50618M H50623M-2 4411 DESCRIPTION DUST CAP (SOCKET ASSY, GREEN) BLOCK (CONTACT, SOCKET, 10 HOLE) BODY (SOCKET, MOLDED) FACEPLATE (SOCKET, THERMISTOR) GASKET (SOCKET BODY, NEOPRENE) SCREW (#6-32 X 1/2, CRS FCS, S.S.) NAME PLATE (4400 API THERMISTOR SOCKET) SCREW (5/16-18 X 3/4 S.S.) WASHER (5/16 S.S.) SPACER (RND, S.S.) CONTACT (BUTTON, SOCKET) INSERT (BUTTON, SOCKET) ASSY. (WIRE, GROUND, SOCKET) SCREW (#6-32 X 3/8, CRS PAN, S.S.) FACE PLATE KIT (INCLUDES ALL ITEMS EXCEPT ITEM 3) QTY. 1 1 1 1 1 1 1 2 2 1 8 4 1 1 1 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 PHONE: (816) 741-6600 • (888) 526-5657 • Fax: 741-1061 Cincinnati, OH(816) - Phone: 866.879.9773 - Fax: 513.860.1355 4304 Mattox Road • Kansas City, MO 64150IL•-www.civacon.com Chicago, Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com 187 Section A Petroleum Trailer Parts Civacon Model #1051-007 ROM Optic Sensor (2-Wire 2" NPT) Replacement Par t s Rev. A, March 2006 4 13 4 1/16" 2 9 7 3 1/4" 11 3 12 14 8 1/2" NPT 5 10 3 5/16" 6 15 1 5" (MIN.) 7" (MAX.) 188 ITEM PART NUMBER 1 N/A 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1351-007 1355-1355 C40030A D40023A H50066M H50080M H50083M H50086M H50088M H50153M H50276M H50279M H50371M H50476M H50524M H50070M DESCRIPTION OPTIC SENSOR PROBE HOUSING (INCLUDES ALL ITEMS EXCEPT ITEMS 1 & 13) UPPER HOUSING CAP LOWER HOUSING BODY DRIVE SCREW O-RING (BODY SENSOR TUBE) LOCK NUT (2" N.P.T.) WASHER (1/4" SPLIT, S.S.) O-RING (PROBE ADJUSTING SCREW) SCREW (1/4-20 X 1/2 STL, FIL, S.S.) GASKET (BASE SENSOR) O-RING (CAP SENSOR) PROBE ADJ. SET SCREW (1/4-20 X 27/32 STL, FIL, S.S.) NAME PLATE (1050 SENSOR) GREEN GROUNDING SCREW (#8-32 X 3/8 CMB, BND, DC) PIPE PLUG (1/2" N.P.T.) QTY. 1 N/A 1 1 2 1 1 2 1 2 1 1 1 1 1 1 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com www.littlejohninc.com Section A Petroleum Trailer Parts Civacon Model #1110 Optic Sensor (5 Wire 2" NPT) Replacement Par t s Rev. 0, January 2003 4 12 4 1/16" 2 9 7 3 1/4" 11 3 13 14 8 1/2" NPT 5 10 3 5/16" 6 15 1 5" (MIN.) 7" (MAX.) ITEM PART NUMBER 1 N/A 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1300 1355 C40030A D40023A H50066M H50080M H50083M H50086M H50088M H50153M H50276M H50279M H50284M H50371M H50524M H50070M QTY. DESCRIPTION OPTIC SENSOR PROBE HOUSING (INCLUDES ALL ITEMS EXCEPT ITEMS 1, 4 & 12) UPPER HOUSING CAP LOWER HOUSING BODY DRIVE SCREW O-RING (BODY SENSOR TUBE) LOCK NUT (2" N.P.T.) WASHER (1/4" SPLIT, S.S.) O-RING (PROBE ADJUSTING SCREW) SCREW (1/4-20 X 1/2 STL, FIL, S.S.) GASKET (BASE SENSOR) O-RING (CAP SENSOR) NAME PLATE (1110 SENSOR) PROBE ADJ. SET SCREW (1/4-20 X 27/32 STL, FIL, S.S.) GREEN GROUNDING SCREW (#8-32 X 3/8 CMB, BND, DC) PIPE PLUG (1/2" N.P.T.) 1 N/A 1 1 2 1 1 2 1 2 1 1 1 1 1 1 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 PHONE: (816) 741-6600 • (888) 526-5657 • Fax:OH (816) 741-1061 Cincinnati, - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, - Phone: 800.621.7131 - Fax: 708.442.9229 4304 Mattox Road • Kansas City, MO 64150 •ILwww.civacon.com www.littlejohninc.com 189 Section A Petroleum Trailer Parts Civacon Model #1550 Thermo-Optic Quick Start Probe (2-wire 2" NPT) Replacement Par t s Rev. 0, January 2003 4 13 4 1/16" 2 9 7 3 1/4" 11 3 12 14 8 1/2" NPT 5 10 3 5/16" 6 15 1 5" (MIN.) 7" (MAX.) 190 ITEM PART NUMBER 1 N/A 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1650-1650 1355-1355 C40030A D40023A H50066M H50080M H50083M H50086M H50088M H50153M H50276M H50279M H50371M H50421M H50524M H50070M DESCRIPTION OPTIC SENSOR PROBE HOUSING (INCLUDES ALL ITEMS EXCEPT ITEMS 1 & 13) UPPER HOUSING CAP LOWER HOUSING BODY DRIVE SCREW O-RING (BODY SENSOR TUBE) LOCK NUT (2" N.P.T.) WASHER (1/4" SPLIT, S.S.) O-RING (PROBE ADJUSTING SCREW) SCREW (1/4-20 X 1/2 STL, FIL, S.S.) GASKET (BASE SENSOR) O-RING (CAP SENSOR) PROBE ADJ. SET SCREW (1/4-20 X 27/32 STL, FIL, S.S.) NAME PLATE (1550 SENSOR) GREEN GROUNDING SCREW (#8-32 X 3/8 CMB, BND, DC) PIPE PLUG (1/2" N.P.T.) QTY. 1 N/A 1 1 2 1 1 2 1 2 1 1 1 1 1 1 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com www.littlejohninc.com Section A Petroleum Trailer Parts Civacon PARTS BREAK DOWN 4100-4100 Optic Socket API Pattern for Optic Output ITEM 1 PART NUMBER C40011M 2 2 DESCRIPTION CONTACT BLOCK QTY. 1 ITEM 13 PART NUMBER C51503M 2 2 DESCRIPTION LABEL, TECH ASSISTANCE QTY. 1 2 D40103AH FACEPLATE, OPTIC 1 14 H50618M GROUND WIRE 1 3 D40100A BODY 1 15 H50025M1,2 DUST CAP, BLUE 1 4 H50616M2 CONTACT, BUTTON 6 16 H50288M1,2 CABLE 1 5 H50064M2 GASKET 1 17 H50290M1,2 RIVET 1 6 H50617M 2 18 H50292M 1,2 WASHER 1 7 H50074M 2 H50293M 1,2 LOGO WASHER 1 8 H50623M-22 9 INSERT 4 SCREW, #6-32 1/2” 1 SCREW, #6-32 3/8” 1 H50107M2 NAME PLATE 1 10 H50108M2 SCREW, 5/16-18 3/4” 2 11 H50250M 2 WASHER, 5/16 SS 2 4150-4150 DUST CAP H50291M 2 SPACER 1 4110-4110 FACE PLATE KIT 12 19 REPAIR KITS 1 - Included in 4150-4150, 2 - Included in 4110-4110 PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com Rev. +, July 2009 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com 191 Section A Petroleum Trailer Parts Civacon Model #4401 Socket API pattern for thermistor output Replacement Par t s Rev. A, March 2006 1 10 11 12 8 2 9 6 4 7 13 14 5 3 192 ITEM PART NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 N/A 4450 C40011M D40100A D40102AH H50064M H50074M H50136M H50108M H50250M H50291M H50616M H50617M H50618M H50623M-2 4411 DESCRIPTION DUST CAP (SOCKET ASSY, GREEN) BLOCK (CONTACT, SOCKET, 10 HOLE) BODY (SOCKET, MOLDED) FACEPLATE (SOCKET, THERMISTOR) GASKET (SOCKET BODY, NEOPRENE) SCREW (#6-32 X 1/2, CRS FCS, S.S.) NAME PLATE (4400 API THERMISTOR SOCKET) SCREW (5/16-18 X 3/4 S.S.) WASHER (5/16 S.S.) SPACER (RND, S.S.) CONTACT (BUTTON, SOCKET) INSERT (BUTTON, SOCKET) ASSY. (WIRE, GROUND, SOCKET) SCREW (#6-32 X 3/8, CRS PAN, S.S.) FACE PLATE KIT (INCLUDES ALL ITEMS EXCEPT ITEM 3) QTY. 1 1 1 1 1 1 1 2 2 1 8 4 1 1 1 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com www.littlejohninc.com Section A Petroleum Trailer Parts Civacon PARTS BREAK DOWN 4820 Dual Socket ITEM PART NUMBER 1 C40151A-3 2 2 C40151A-41 3 C40011M1,2 4 1,2 H50073M 1,2 5 H50401M-02 6 H50290M3,4 7 8 DESCRIPTION QTY. ITEM PART NUMBER DESCRIPTION QTY. “J” SLOT SOCKET - 3 1 15 D52550M BASE 1 “J” SLOT SOCKET - 4 1 16 H52551M LABEL 1 CONTACT BLOCK 2 17 H52552M PLATE 1 SCREW, #8-32 3/8” 8 18 H50086M LOCK WASHER, 1/4” 6 WASHER, #8 8 19 9485 WASHER, 1/4” 6 RIVET 2 20 H52553M GASKET 1 H50292M 3,4 WASHER 2 21 H50114M SCREW, 1/4-20 3/4” 6 H50293M 3,4 LOGO WASHER 2 22 H50070M PIPE PLUG 1 3,4 CABLE 2 DUST CAP, GREEN 1 DUST CAP, BLUE 1 C40151-THERM REPL. THERMISTOR FACE PLATE 15’ C40151A-OPTIC REPL. OPTIC FACE PLATE STRAIN RELIEF 1 4150-4150 DUST CAP, BLUE GASKET 2 4450-4450 DUST CAP, GREEN 9 H50288M 10 H50065M4 11 H50025M 3 12 97701 13 H50221M 14 H52479M1,2 CABLE, 7 COND. 20 GA BK REPAIR KITS 1 - Included in C40151-THERM, 2 - Included in C40151A-OPTIC, 3 - Included in 4150-4150, 4 - Included in 4450-4450 PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com Rev. +, July 2009 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com 193 Section A Petroleum Trailer Parts Civacon 5-Wire Optic Level Sensor Rev. A, Mar 2010 Civacon introduces our new 5-Wire Optic Sensor. The new sensor and housing includes digital technology and improved design features. This sensor is the perfect fit for your overfill detection needs. Optic overfill sensors detect the presence of liquid at a preset level. The new Civacon 5-Wire Sensor is fully compatible with all our current 5-Wire Sensors and Monitors, as well as all industry standard signal formats. These new Sensors feature an exclusive, digital electronic circuitry design that will work directly with 5-Wire loading racks when wired directly to a blue WOGA1 or SAE J-560 style “optic” socket, as well as with all Onboard Monitors like our Civacon Liberty™. The new Civacon 5-Wire Sensors are a direct replacement for our 5-Wire Liberty™ optic sensors. The new 5-Wire output signal is compatible with the industry standard signal format, which makes it the right choice for any of your 5-Wire overfill detection sensor applications. All of the features & benefits of these new sensors are also available in our new 2-wire sensor version as well (see separate data sheet). Overfill Features • 5-Wire Probe output signal is compatible with the industry standard output format • New digital electronics with new temperature stabilized friendly potting • Zero glue or adhesive construction for wide chemical compatibility • Still the industries best single flat surface optic prism design! • Recessed, protected one piece molded, all glass Pyrex® prism • Completely new Housing and Cap design • Molded non-corrosive cap with captive seal means no tools required for access, or adjustment of probe • Tamper Evident Tab on Cap lets you add a seal to prevent Sensor Tube Retaining Spring. Squeeze ends together to adjust sensor height. sensor height tampering (sensor can not be adjusted externally) • Housings and Replacement Sensors are 100% compatible with all previous Civacon 5-Wire models • Approved to North American, Europe (ATEX) and World (IECEX) Tamper Evident Tab 1. WOGA (Western Oil and Gas Association), the former name for the Western States Petroleum Association (WSPA) • Operating Temperature -40º F (-40º C) to 160º F (71.1º C) Storage Temperature -70º F (-56.6º) to 280º F (137.7º C) PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com 194 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com 5-Wire Optic Level Sensor Section A Petroleum Trailer Parts Civacon Product Specifications Product Number 1112-007, 0012 or 0018 (See Below) Sensing Length Adjustability See Drawing Product Range Refractive Index 1.37 to 1.60 Viscosity of less that 1000 SSU Electrical Leads 22 ga. Stranded Wire 26” Long Weight 1.15 lbs. (0.521 kg) Materials Sensor Cap - Glass Filled Nylon Cap O-ring - Silicone Sensor Housing - Aluminum Mounting O-ring - Viton Locking Nut - Plated Steel Sensor Shaft - Aluminum Prism - Pyrex® Glass Prism O-ring - Fluorosilicon Snap Ring - Stainless Approvals North American Europe (ATEX) World (IECEX) Temperature Range Operating Temperature -40º F (-40º C) to 160º F (71.1º C) Storage Temperature -70º F (-56.6º) to 280º F (137.7º C) **Special length sensors are available upon request REFERENCE CHART 5-Wire Part # Old Civacon Part # Description 1112-007 1110-1110 Optic Overfill Sensor, 5-Wire, 2” NPT Parallel Port Housing, 7” 1112-0012 1110-0012 Optic Overfill Sensor, 5-Wire, 2” NPT Parallel Port Housing, 12” 1112-0018 1110-0018 Optic Overfill Sensor, 5-Wire, 2” NPT Parallel Port Housing, 18” 1302-007 1300-1300 Replacement Optic Overfill Sensor, 5-Wire, No Housing, 7” 1302-0012 1300S-0012 Replacement Optic Overfill Sensor, 5-Wire, No Housing, 12” 1302-0018 1300S-0018 Replacement Optic Overfill Sensor, 5-Wire, No Housing, 18” PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com 195 Section A Petroleum Trailer Parts Civacon 2-Wire Socket Optic Level Sensor w/ Housing Rev. C, MAY 2010 70000PA Civacon introduces our new Socket Optic Overfill Sensor. A completely new sensor and housing with enhanced technology and design features. The non– polarized digital electronic circuitry design is a perfect fit for all your overfill detection needs. Optic overfill sensors detect the presence of liquid at a preset level. The new Civacon Socket Sensor is fully backward compatible with our current Quick-Start™ Sensors and Monitors, as well as all industry standard signal formats. These new Socket Sensors feature an exclusive, nonpolarized digital electronic circuitry design that will work directly with 2-wire (green plug) loading racks when wired directly to a green “thermistor” socket, as well as with all on-board Monitors like the Civacon ROM II. The sensor’s non-polarized electronic design means not having to worry about the sensor’s wire color or polarity anymore. The two grey wires can be wired as either signal or ground interchangeably. You can not wire it wrong! The new Civacon Socket Sensors are a direct replacement for our 2-wire, Quick-Start™ (white & black wire) optic sensors. With their 2-wire industry compatible signal format, they are a perfect choice for your 2-wire overfill detection sensor applications. Overfill Features • 2-Wire Socket Sensor will work with ROM II and Quick Start 2-Wire Systems • Two grey wires for non-polarized connection as signal or ground • New digital electronics with extended temperature-stabilized potting • Dual o-ring seals in housing for improved sensor shaft-to-housing sealing • Zero glue or adhesive construction for wide chemical compatibility • Still the industries best single flat surface optic prism design! • Recessed, protected one piece molded, Borosilicate glass prism The features & benefits of these new sensors are also available in our new 5-wire sensor version as well. (call us for more details) • Completely new Housing and molded non-corrosive Cap design • No tools required for access, or adjustment of probe • Approved to North American, Europe (ATEX) and World (IECEX) Standards Sensor Tube Retaining Spring. Squeeze ends together to adjust sensor height. • Operating Temperature -40º F (-40º C) to 160º F (71.1º C) Storage Temperature -70º F (-56.6º) to 280º F (137.7º C) • OPTIONAL: Tamper Evident Tab on cap lets you add a seal to Tamper Evident Tab prevent sensor height tampering (sensor can not be adjusted externally) PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com 196 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com Product Specifications Product Number Materials 1552G-007, 0012 or 0018 (See Below) Sensor Cap - Glass-Filled Nylon 1652G-007, 0012 or 0018 (See Below) Cap O-ring - Silicone Sensor Housing - Aluminum Sensing Length Adjustability Mounting O-ring - Viton See Drawing Locking Nut - Plated Steel Sensor Shaft - Aluminum Product Range Prism - Borosilicate Glass Refractive Index 1.37 to 1.60 Prism O-ring - Fluorosilicon Viscosity of less that 1000 SSU Retaining Ring - Stainless Steel Electrical Leads Two 18 ga. Stranded Wire 26” Long (Grey in Color) Weight 1.15 lbs. (0.521 kg) (with housing) Section A Petroleum Trailer Parts 2-Wire Socket Optic Level Sensor w/ Housing Civacon Approvals North America Europe (ATEX) World (IECEX) Temperature Range Operating Temperature -40º F (-40º C) to 160º F (71.1º C) Storage Temperature -70º F (-56.6º) to 280º F (137.7º C) REFERENCE CHART Socket Optic Sensor Part # Old Quick Start Part # Description 1552G-007 1551-007 Optic Overfill Sensor, 2-Wire, 2” NPT Parallel Port Housing, 7” 1552G-0012 1551-0012 Optic Overfill Sensor, 2-Wire, 2” NPT Parallel Port Housing, 12” 1552G-0018 1551-0018 Optic Overfill Sensor, 2-Wire, 2” NPT Parallel Port Housing, 18” 1652G-007 1651-007 Replacement Optic Overfill Sensor, 2-Wire, No Housing, 7” 1652G-0012 1651-0012 Replacement Optic Overfill Sensor, 2-Wire, No Housing, 12” 1652G-0018 1651-0018 Replacement Optic Overfill Sensor, 2-Wire, No Housing, 18” 1455-1455 1355-1355 2” NPT Parallel Port Housing w/ Cap 12214 N/A Tamper Evident Tab Kit PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com 197 Section A Petroleum Trailer Parts Civacon 198 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com Section A Petroleum Trailer Parts Civacon Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com 199 Section A Petroleum Trailer Parts Civacon 200 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com Section A Petroleum Trailer Parts Civacon Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com 201 Section A Petroleum Trailer Parts Scully 202 Scully Intellicheck 2 Monitor Part Number Model 09109 Overfill Monitor Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com Item Part Number Description 1 09132 Cover assy... 2 32600 Cover 3 32601 Window 4 31787 Cover gasket 5 50151 Screw 6 51122 Lock washer 7 09111 Module 8 32599 Base 9 31820 Switch 10 50740 31616 Pipe plug Fuse holder 11 31842 Standoff Scully Load Anywhere® System Complete Overfill Prevention Loading Rack Compatibility Featuring Dynacheck ® - Automatic and Continuous Self-Checking Circuitry Section A Petroleum Trailer Parts Scully Scully truck mounted control monitor and sockets The Scully Load Anywhere® Overfill Prevention System offers the maximum safety in tank truck loading operations. System components include the Scully Load Anywhere Control Monitor, Optic Sensors and Optic, Thermistor or Float Sockets. The Scully Load Anywhere System offers all these advantages: • Durable construction for long-lasting • Complete compatibility with Scully Optic dependability. and Thermistor Rack Control Monitors the #1 choice of over 90% of all bottom Optic sensors Load Anywhere® System• Replacement Partsthat defeat fogging. loading terminals in the United States. Description Part # • Resistance to a wide range of temperatures. • Dynacheck ® - automatic and continuous Load Anywhere Control Monitor only 08687 • Easy installation with step by step instructions. self-checking circuitry for maximum safety Load Anywhere Control Module only 08563 through electronic Load Anywhere Retrofitmonitoring. Kit for Old Style Monitor, including New• Module and Face PlateinAssembly 08518 The best service the business with toll-free Load Anywhere compartment cover assembly • Over 30 years6 of field-proven performance Optic sensor with holder, 7" making Scully the #1 choice worldwide. • 07894 • A complete system with monitor, sensors, Optic sensor only, 7" 21500 sockets and installation kit. On/Off dashboard mounted, push-pull power control switch 58000 No manual checks are needed. Complete Installation kit with 100' Scully cable, 16 cable fittings, 30 crimp-on connectors, 1 on/off switch, 08309 1/4 ampere in-line fuse and 1 socket cleaner Optic/Thermistor installation kit with 100' Scully Cable, 16 cable fittings, 30 crimp-on connectors 08399 100' of special Scully cable 22056 16 cable fittings 27555 30 crimp-on connectors 22255 Socket cleaner only 07811 Load Anywhere Installation and Service 08679 ® Video See our IntelliCheck Brochure for the latest in Tank Truck Overfill Prevention Optic sensor with holder, 12" 08698 and Retained Product Monitoring. Optic sensor only, 12" 08758 Description Socket Replacement Parts Setting New Standards In Safety Housing for all socket models Blue Vinyl Cap, SJ-6W, SJ-6SO, SJ-6X Sockets Green Vinyl Cap, SJ-6S, SJ-6 Sockets Scully Signal Company, 70 Industrial Way, Wilmington, MA 01887 U.S.A. Vinyl Cap, SJ-F, SJ-6F Sockets Tel (617) 692-8600,Red Fax (617) 692-8620 Contact assembly for SJ-6S socket Contact assembly for SJ-6SO & SJ-6W socket Contact assembly for SJ-F socket Contact assembly for SAE J560 sockets Housing gasket for all socket models Replacement single pin and screw for all sockets 60671 08712 trouble-shooting and maintenance assistance. Part # 21810 08575 08574 08576 20757 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 21771 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 21104 www.littlejohninc.com 27450 20628 07783 203 Section A Petroleum Trailer Parts Scully 1/2" NPT CONDUIT ENTRY 2 HOLES 2.12" (54) 1/2" NPT CONDUIT ENTRY 2 HOLES 2.12" (54) Ø.26" ( Ø 6.6) THRU HOLE ON Ø 4.25" (Ø 108) BOLT CENTER 6 MTG HOLES EQ. SPACED 3.62" (92) 3.62" (92) 2" NPT VITON, GASKET LOCK NUT 5.19" TO 6.93" (132 TO 176) 5.19" TO 6.38" (132 TO 162) Ø5.12" (Ø130) SP-TO/MHC SP-TO/MHCF Ø.26" ( Ø 6.6) DRILL POINT SPOT (118º) ON A HOLDER MOUNTING SP-TO/MHCF Ø 4.50" (Ø114) BOLT CENTER 4 PLACES Technical Specifications Operating Temperature Range -40° F to +140° F (-40° C to +60° C) Product Range Gasoline blends and light fuel oils Exposed Materials Aluminum, zinc, borosilicate (Pyrex®) glass, epoxy, conductive nylon and Viton® seals Detection Level and Size The detection level is adjustable. Refer to sensor outline drawing above, shown for 7" shaft length. Level Repeatability ±1/16" (1 mm) Electrical Leads 18" (45 cm) long, 18 AWG (0.82 mm2) Cable Entry Two holes, 1/2" NPT threads Approvals The sensor is intrinsically safe for mounting in Class I, Division 1, Groups C & D Hazardous location in accordance with Scully Control unit approval ratings Ordering Information Model Description Shaft Length Part Number SP- FU/MHC Five-wire optic sensor, 2" NPT holder, 2-1/8" standard cap 7" (175mm) 12" (300mm) 15" (375mm) 09208 09213 09216 SP- FU/MHCF Five-wire optic sensor, flanged holder, 2-1/8" standard cap 7" (175mm) 12" (300mm) 09207 09212 Model Description SP-FU SP-FU SP-FU Five-wire optic sensor (without holder) Replacement Parts Part Number 7" (175mm) 12" (300mm) 15" (375mm) Shaft O-ring 09209 09214 09217 08577 SP-MHC 2" NPT Threaded Holder Only 09065 SP-MHCF Flanged Holder Only 08265 Mounting Gasket for SP-MHC Holder 20893 Mounting Lock Nut for SP-MHC Holder 57044 Mounting Gasket for SP-MHCF Holder 21451 Cap O-ring 20766 Short Cap (SC), height 1.38" (35mm) 21583 Medium (Standard) Cap (MC), height 2.13" (54mm) 20888 Cap screw 50652 Cap screw spring washer 51122 Biclops, Dynacheck, Dynamic Self-Checking, Faylsafe, Load Anywhere, IntelliCheck, Intellitrol, IntelliTank, Intelliview, Maxsafety, MulteCept, Sculcon, Scultrol, Scully, R.S.V.P., TABS and Scully V.I.P. are registered trademarks of Scully Signal Company. Viton is a registered trademark of DuPont. Specifications are subject to change without notice. Corporate Headquarters Scully Signal Company S O 90 I 0 scully 70 Industrial Way Wilmington, MA 01887 Tel: (800) 272-8559 • (617) 692-8600 Fax: (617) 692-8620 email: sales@scully.com • www.scully.com 1 IS 204 © Spartanburg, Scully Signal Company. SC - Phone: 800.828.6555 - Fax: 864.583.1550 Printed in the U.S.A. Cincinnati, OH - Jan2000/60678revB Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com N Y G RE T E RE D M CO P A 1/2" NPT CONDUIT ENTRY 2 HOLES 2.12" (54) 1/2" NPT CONDUIT ENTRY 2 HOLES 2.12" (54) Ø.26" ( Ø 6.6) THRU HOLE ON Ø 4.25" (Ø 108) BOLT CENTER 6 MTG HOLES EQ. SPACED 3.62" (92) 3.62" (92) Section A Petroleum Trailer Parts Scully 2" NPT VITON, GASKET LOCK NUT 5.19" TO 6.93" (132 TO 176) 5.19" TO 6.38" (132 TO 162) Ø5.12" (Ø130) SP-TO/MHC SP-TO/MHCF Ø.26" ( Ø 6.6) DRILL POINT SPOT (118º) ON A HOLDER MOUNTING SP-TO/MHCF Ø 4.50" (Ø114) BOLT CENTER 4 PLACES Technical Specifications Operating Temperature Range -40° F to +140° F (-40° C to +60° C) Product Range Gasoline blends and light fuel oils Exposed Materials Aluminum, zinc, borosilicate (Pyrex®) glass, epoxy, conductive nylon and Viton® seals Detection Level and Size The detection level is adjustable. Refer to sensor outline drawing above, shown for 7" shaft length. Level Repeatability ±1/16" (1 mm) Electrical Leads 18" (45 cm) long, 18 AWG (0.82 mm2 ) Cable Entry Two holes, 1/2" NPT threads. Approvals The sensor is intrinsically safe for mounting in Class I, Division 1, Groups C & D Hazardous location in accordance with Scully Control unit approval ratings Ordering Information Model Description SP-TO/MHCF Two-wire optic sensor, flanged holder, 35mm standard cap SD-5C 5-Element Electronic Dummy Model Description SP-TO/MHC Shaft Length Two-wire optic sensor, 2" NPT holder, 2-1/8" standard cap Part Number 7" (175mm) 12" (300mm) 15" (375mm) 7" (300mm) 12" (300mm) 15" (375mm) 09408 09413 09416 09407 09212 09415 Employed on tank trucks with less than 6 compartments (8 in Canada) when not using IntelliCheck monitor 08298 Replacement Parts SP-TO SP-MHC SP-MHCF Shaft Length Two-wire optic sensor (without holder) 7" (175mm) 12" (300mm) 15" (375mm) Shaft O-ring 2" NPT Threaded Holder Only Part Number 09409 09414 09417 08577 09065 Flanged Holder only 08265 Mounting Lock Nut for SP-MHC Holder 57044 Mounting Gasket for SP-MHC Holder 20893 Mounting Gasket for SP-MHC Holder 21451 Cap O-ring 20766 Short Cap (SC), height 1.38" (35mm) 21583 Medium (Standard) Cap (MC), height 2.13" (54mm) 20888 Cap screw 50652 Cap screw spring washer 51122 Biclops, Dynacheck, Dynamic Self-Checking, Faylsafe, Load Anywhere, IntelliCheck, Intellitrol, IntelliTank, Intelliview, Maxsafety, MulteCept, Sculcon, Scultrol, Scully, R.S.V.P., TABS and Scully V.I.P. are registered trademarks of Scully Signal Company. Viton is a registered trademark of DuPont. Corporate Headquarters Specifications are subject to change without notice. Scully Signal Company O 90 I S 0 scully 70 Industrial Way Wilmington, MA 01887 Tel: (800) 272-8559 • (617) 692-8600 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Fax: (617) 692-8620 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 email: sales@scully.com • www.scully.com 1 IS © Scully Signal Company Printed in the U.S.A. Jan2000/60715revB N Y G RE T E RE D M CO P A www.littlejohninc.com 205 6 Compartment Load Anywhere Kit 08311 Scully Two-Wire Optic Socket Advanced Optic Sensing Section A Petroleum Trailer Parts Scully Scully Optic Sensors are the sensingOverfill device through which Dynacheck detects the presence of 1-8 liquidCompartme Prevention For Road Tankers with product in the truck compartment. The sensors are set at a predetermined high level. Optic technology insures no warm-up time and the ability to “see” liquid product. One sensor is mounted in each compartDescription ment. The optic probes are adjustable at the time of installation for a variety of sensing depths, and are fitted with a permanent protector. Scully Optic Sensors are extremely resistant to fogging and handle a The Scully Two-wire optic so wide variety of temperatures and liquid products. Refer to technical to connect up to 8 tanker mount data sheet #60678 for more information. optic sensors to the Scully Biclo Prevention Monitor via the Scully Plug and Cable Unit. Durable, Reliable Connections Scully Sockets are the vehicle mounted connectors for the rack plug. Sockets feature lightweight vinyl protective caps to prevent socket corrosion by protecting the contact pins from dirt and moisture. A captive cable attachment is also included to prevent loss. Sockets consist of durable construction to withstand the rigors of road travel. Refer to technical data sheet #60674 for more information. Scully Two-Wire Optic Socket with Polyvinyl Cap Sockets Information • Suitable for Socket ScullyOrdering two-wire optic sensors Description (All sockets includeto the vinyl protective • Caters top and bottomcap) loading SJ-6S Thermistor, API•Standard Rugged construction SJ-6 Thermistor, J560 Pattern • Incorporates electronic dummy for tankers Above are compatible with the less ST-6 and Control Monitors with thanBiclops eightRack compartments Easy SJ-6SO Optic, Scully • Pattern installation on tanker chassis • Lightweight SJ-6W Optic, API Standard • Available with integral brake inte switch for top Socket Part loading # • Optional07720 mounting bracket with captive 07681 plate and bolts for top lo • Optional integral pressure switch vapor recovery 07973 • Pins for07974 tanker earthing incorpor polyvinyl cap SJ-6X Optic, J560 Pattern 08199 Above are compatible with the ST-35 and Biclops Rack Control Monitors Principle of Overfill Prevention Emergency Shutdown System Components 07788 SJ-F Float, Scully Pattern Scully 08116 Control switch adaptors Above compatible with the Intellitrol™, ST-6, ST-35 and Biclops Rack Control Monitors with float Monitor SJ-6F Float, J560 Pattern 20770 - Faceplate Assy Thermistor 21790 - Faceplate Assy Optic 07811 - Socket Cleaner Scully Sensor Tanker 08574 - Green Cap 08575 - Blue Cap Scully Socket & Plug Connection Scully Junction Box Output Signal Cable T A S From Pum Loading Hose Loading Rack Valve Rack Setting New Standards In Safety 206 Main Power 67155 Rev A Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 Scully Signal Company, 70 Industrial Way, Wilmington, MA 01887 U.S.A. www.littlejohninc.com Tel (617) 692-8600, Fax (617) 692-8620 Section A Petroleum Trailer Parts Scully Universal Truck Tester Tank Truck Overfill Prevention System Diagnostics The Scully Universal Truck Tester is the most advanced and comprehensive truck tester available. It checks the operation of tank truck overfill prevention, and self-proving grounding systems. Complete diagnostics limit the expense of downtime. • Tests all Scully Optic and Thermister Overfill Sensors, the Intellicheck® System, The Load Anywhere® System and the Liquidometer TABSTM System output. • Simultaneously tests all compartment sensors. • The only tester which will check the operation of the Ground Bolt and Ball. • Shows a more accurate reading than any other tester on the market with test results as either “Good, Poor, or Fail” to easily diagnose service requirements. • A poor reading alerts the driver that it may be time to repair or replace the sensor in question. • A variety of plug and cable assemplies are available according to the socket needs of the user. • Rustproof, weather resistant housing. • Easy to read multicolored LED display. Operation Move the selector switch to the desired setting. Connect the tester to the tank truck socket with the appropriate plug and cable. The test results will be shown clearly on the easy to read LED display. Compatability The tester is compatable with Scully Intellicheck® Load Anywhere®, and independent Scully optic and thermister tank truck sensors. Technical Specifications Power supply: ...............................................8”D” Cell, alkaline batteries Battery access: .....................................Remove 2 screws in front panel Operating temperature range: .............-13˚F to +113˚F (-25˚C to +45˚C) Maximum number of compartments: .....................................................8 Dimensions: ...........................................................................8” x 6” x 4” Weight (without batteries): ...............................................3.8 lbs (1.7Kg) Ordering Information Description Part No. Scully Universal Tester* ................................................................08938 PCAM, 10 Pole Scully Plug and Cable......................................... 08926 PCAM, 6 Pole WOGA Plug and Cable..........................................08927 PCAM, 7 Pole J560 Optic .............................................................08928 PCAM, 4 Pole Plug and Cable ..................................................... 08936 Adapter 7 Pole Scully Optic to J560..............................................07735 *Order appropriate plug & cable with tester. “D” size batteries not included. • Runs on standard “D” size Alkaline batteries. For further information and technical service, please call Scully at (800) 272-8559. Biclops, Dynacheck, Dynamic Self-Checking, Dynamic Self-Test, Faylsafe, Intellicheck, Intellitrol, Intelliview, Load Anywhere, Maxsafety, MulteCept,Scully, Scultrol, Scul-Lock, Scul-Tel, Scul-Tite, TABS and V.I.P. are registered trademarks of the Scully Signal Company Specifications are subject to change without notice Worldwide Contact Scully Signal Company 70 Industrial Way Wilmington, MA 01887 USA Tel: 1-800-272-8559 or (617) 692-8600 Fax: (617) 692-8620 email: sales@scully.com www.scully.com 67252 Rev A © Printed in U.S.A. February 1999 Setting New Standards In Safety Scully Signal Company, 70 Industrial Way, Wilmington, MA 01887 U.S.A. Tel (617) 692-8600, Fax (617) 692-8620 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com 207 Section A Petroleum Trailer Parts Accessories 7523 Brass ground studs 3231 Watertite connections Harness Wire 100’ or 1000’ rolls 208 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com Diagrams Three Wire Diagrams Section A Petroleum Trailer Parts OCS Guide to Installation EBW Transport Systems, 2814 McCracken Ave, Muskegon MI 49441 - Sales Desk 1-800-207-9579, Sales Fax 1-800-475-4329 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com 209 Section A Petroleum Trailer Parts OCS Guide to Installation Diagrams Three Wire Diagrams / with Retain Probes EBW Transport Systems, 2814 McCracken Ave, Muskegon MI 49441 - Sales Desk 1-800-207-9579, Sales Fax 1-800-475-4329 210 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com Section A Petroleum Trailer Parts Diagrams Wiring Schematic For Thermistor System WHITE-GROUND AND SENSOR RETURN PLUG TO SOCKET LOCKING PIN WHITE-AUXILIARY GROUND (OPTIONAL) 8 25 10 11 3 SOCKET TO PLUG LOCKING J- SLOT 10 3 4 9 7 5 BLACK VIOLET-DATA PIN (OPTIONAL) 11 4 5 6 5 THERMISTOR RECEPTACLE (SOCKET) THERMISTOR PLUG 4 YELLOW 3 RED 2 GREEN 1 BROWN COMPARTMENT NUMBER EBW Transport Systems OCS Control Manual 6 BLUE 8 9 7 6 Wiring Schematic For Optical System BLACK-GROUND AND SENSOR RETURN PLUG TO SOCKET LOCKING PIN WHITE-AUXILIARY GROUND (OPTIONAL) 27 8 8 6 SOCKET TO PLUG LOCKING J- SLOT 10 11 4 5 OPTIC PLUG 9 10 VIOLET-DATA PIN (OPTIONAL) 11 4 5 RED-SENSOR POWER (+) 6 ORANGE-RETURN PULSE FROM SENSOR GREEN-DIAGNOSTIC (OPTIONAL) OPTIC RECEPTACLE (SOCKET) YELLOW-PULSE TO SENSOR Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com EBW Transport Systems OCS Control Manual 9 211 IMPORTANT Please read before installing Section A Petroleum Trailer Parts Diagrams 1. The EBW 908-PF is a S.A.E. J-560 pattern socket that conforms to API 1004 Standards. 3. When mounting socket housing using the holes located inside of housing, a sealant should be used around the mounting bolts to prevent moisture from entering. 2. The wiring shown conforms to RP 1004 standards for controlling single stage "float switch" type loading rack overfill control monitors. The user should be aware that other wiring patterns do exist that may prevent loading at these facilities, therefore please consult your loading facility to verify compliance with RP 1004. Float Socket 4. The 6-32" screw located on outside of housing should be in "top" hole when mounted to allow drainage of condensation out the bottom hole. Normally Closed Float Switch VEHICLE GND. 1 WHT 6 2 BLK BRN BLU 7 3 YEL RED VEHICLE GND. GRN 5 4 REAR VIEW OF SOCKET Sales Desk (800) 475-3291 • Sales Fax (800) 475-4329 • Phone (231) 755-1671 ® 2814 McCracken Avenue, Muskegon, MI 49441 • Fax (231) 755-7201 • http://www.ebw.com ©2000 EBW Inc. Form No 1107 4/00 VIP Chip 212 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com Phone: 800.828.6555 Fax: 864.583.1550 www.littlejohninc.com Section A Petroleum Trailer Parts Diagrams Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com 213 Section A Petroleum Trailer Parts Diagrams 214 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com Phone: 800.828.6555 Fax: 864.583.1550 www.littlejohninc.com ROM II H5517PA4.WPG Section A Petroleum Trailer Parts Diagrams 10 WIRING INSTRUCTIONS - SOCKETS Locate and mount the socket housings, using the bolt holes provided on the enclosure, in the vicinity of the bottom loading adapters. Take into account the plug and cable that will be coming from the rack monitoring equipment so that it does not interfere with the bottom loading adapters when connected. Conduit openings are provided at the OBM so that each type of socket used may have its own conduit connection only if the auxiliary inputs are not used. If the auxiliary inputs are used, use the convention shown in Figure 2. It combines the Thermistor and Float outputs into one cable exit. This convention is not required but will help in troubleshooting and tracing the system output if a problem should occur. Cross reference the CIVACON part number of the socket to its proper wiring diagram and connect accordingly (refer to Figures 6, 7, and 8 ). Please use the CIVACON Instruction Sheet H50200PA, which is packaged with each socket, for additional reference information on the sockets. Strain reliefs are recommended for all cable entry locations. Note that pipe plugs are required to be installed in all of the openings which are not used for cable entry. A thread sealant is also recommended to be used with each strain relief or pipe plug. SuitableFIGURE for connection to the Intrinsically Safe outputs CIVACON 5 - POWER AND INTRINSICALLY SAFEfrom WIRING Rack Monitors, Models 8100 Series, DIAGRAM 8300 Series, 8400 Series. CONTROL Additional Notes: CIVACON OPTIC SOCKETS 1Electrical Apparatus connected to the Onboard Monitors should not use or generate more than 250 Volts. Match your socket model number with the model numbers below. 2Installation be inwires accordance NEC ANSI/NFPA and ANSI/ISA RP12.6 . In Canada, Connectshould the shown below to with the OPTIC section of the70terminal strip on the monitor. the system must be installed in accordance with the Canadian Electrical Code. CAUTION: The OPTIC RED and ORANGE wires are NOT the same wires as the o o C (140 F) . wires. 3Maximum ambient temperature is 60 THERMISTOR 4Maximum cable capacitance of 10.1 uF and cable inductance of 4.7 mH must not be exceeded. (FMRC Only Parameters) MODEL No.'s 4100, 4200, & 4201 MODEL No. 4300 5Model 3202 Intrinsically Safe Field Wiring parameters (FMRC Only) for TB3 Terminals BRN/BRN/BLK, ORN/RED/BLK, and RED/ORN/YEL/BLK are : Vmax. = 30 V. Vmax. ≥ Voc or Vt; Ci = 0 uF. Ca ≥ Ci + Ccable; Imax. = 250 mA. Imax. ≥ Isc or It; Li = 0 mH. La ≥ Li + Lcable. 6Maximum entity parameters (FMRC Only) for terminals TB5-1, 3, 5 (AUX INPUTS) are: Vt = 12.8 V. Ca = 8 uF. Also see Note 5 parameters. It = 8 mA. La = 1 H. Also see Note 5 parameters. 7TB4A, TB4B, & TB5-1, 3, 5 inputs are for simple switch mechanisms with NO inductance or capacitance. They provide Intrinsically Safe circuits for passive switches or jumpers with NO energy storing or discharging capability. 8CIVACON devices connected to TB2 are sensor Models 1050, 1020, 1000, 1001, and replacement 1350; plus special length versions of the same models with an "S" suffix. 9Auxiliary Output terminal (Aux Out of TB5-6) can be connected to Auxiliary Input of secondary Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 OBM module. Do not cross connect. Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 - Phone: 800.621.7131 - Fax: 708.442.9229 10 CIVACON devices connected to TB3 are Intrinsically Safe Chicago, outputsIL from rack monitor Models 8100 FIGURE 6 - OPTIC www.littlejohninc.com series, 8300 series, and 8400 series. The connections are less than 50 feet. VIEWED FROM WIRE CONNECTION SIDE 11 Do not modify this control diagram without notifying all approval agencies. 12 The following diagrams are part of Figure 5. Diagram A1, A2, A3, A4, A5, & A6. 215 Section A Petroleum Trailer Parts Diagrams DIAGRAM A5 - 5 COMPARTMENT Phone: 800.828.6555 Fax: 864.583.1550 CIVACON www.littlejohninc.com © Copyright 1997 216 15 Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 598 Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355 Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229 www.littlejohninc.com Ph H51517PA MAY 1997