Overfill - Littlejohn, Inc.

Transcription

Overfill - Littlejohn, Inc.
ROMLink™ “Plug-N-Load” System
Rev. A, May 2009
Section A
Petroleum Trailer Parts
Civacon
Civacon’s retrofit kit, is a link
to a fast installation and worry
free future. The ROMLink™
gives you a hassle free
installation which allows you
to “Plug-N-Load”.
The Civacon ROMLink™ “PLUG-N-LOAD”
System represents a major revolution in the
Overfill Detection World. Since the introduction
of overfill electronics on petroleum and other
product hauling tankers, OEM’s, Installers,
Repair Shops and End Users have been
frustrated by the way in which electronics and
other components are connected together in the
system. Unless the crimps are installed with
absolute precision, the longevity of the system is
compromised.
In the desire to eliminate this frustrating cycle,
Civacon has developed the ROMLink™ “PLUGN-LOAD” System. This system not only
improves trouble points, but eliminates them.
Before
After
Features and Benefits
•
•
•
•
•
•
Crimp Free Installation
No Special Tools or Training Required
Fits All Compartment Layout Configurations
Can be added to existing trucks with overfill systems
Completely Sealed harness system that will last in
any environment
Components color coded for easy identification
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061
4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
177
Section A
Petroleum Trailer Parts
Civacon
3100 5-wire monitor
ROMBolt
II Monitor
Model GS1000 – SAF-T3202
Ground
Kit
The Civacon Model GS1000
SAF-T Ground Bolt Kit
offers the safety, compatibility
and value you expect.
The Civacon Model GS1000 SAF-T Ground Bolt Kit
includes our Ground Verification Bolt for use on
Tankers that load at Terminals where the Loading
Rack Monitor requires a special modified signal as part
of their ground verification operation.
The Civacon Model GS1000 SAF-T Ground Bolt is a
direct replacement of other similar Ground Bolts, and
fully compatible with all Loading Rack Monitors that
require this type of device.
For proper operation, it MUST be securely fastened to
the tanker chassis, and wired to Pin No. 9 of the
Overfill Detection Sockets) to provide proper ground
verification.
4100 Thermistor socket
4400 Optic socket
178
The Civacon Model GS1000 SAF-T Ground Bolt Kit
comes with all of the hardware needed to provide a
secure, trouble-free installation on any tanker
configuration.
4820 Dual socket assy
GS1000 Grounding bolt
Features and Benefits
•
Strong, Stainless Steel Construction.
•
Long, 5-1/2 foot (165cm) Wire.
•
Two Internal-Tooth Stainless Steel Lockwashers.
•
Corrosion-resistant Strain Relief Fitting.
•
Two Electrical Terminals to fit all Socket Styles.
•
Sturdy Round Label to identify the Ground Bolt
and cover and protect area around it.
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
Ordering Specifications
GS1000
SAF-T Ground Bolt Kit
Three Wire OCS System
Section A
Petroleum Trailer Parts
EBW
Three Wire OCS System
All OCS Control Modules perform
continuous self-testing of all probes
for a dry condition, wet condition, or
faulted condition. All OCS Control
Modules perform continuous selftesting of the wiring between the
probes and controllers. All OCS
Control Modules continuously test for
broken wires, shorted ground wires,
shorted power wires, and shorted
signal wires. All OCS Control
Modules monitor for the proper input
signal and proper input voltage from
the rack monitor. OCS Control
Module will allow permit to load only
after proper signals are received from
the rack monitor.
Features and Benefits
• Micro-Processor Base Controller
• Monitors external inputs
• Internal relay outputs
• Waterproof housing with clear
viewing lens
• FM Approved for Hazardous
(Classified) Locations.
• Continuous Self Testing of
• All Probes Attached
• All Probe and Power Wiring
• Rack Input Signals for Terminal
• Proper Input Voltage
Part No.
890-401-03
890-201-03
Description
Controller mounted in Waterproof Housing
Control Module Only
Three Wire OCS Optic Probes
EBW Transport Systems dedication
and commitment to customer
satisfaction and service will be
equaled to none when it comes to
making sure their customers are the
most satisfied in the World. EBW
Transport Systems stands ready to
raise the bar when it comes to
customer service and EBW Transport
Systems will make sure this
dedication and commitment reaches
beyond the normal service calls and
inquiries.
Features and Benefits
• Probes feature surface mount
military spec electronic components
• Probes are compatible with all
existing EBW Controllers
• Operating Temperature
-40 degF - +160 degF
• Three-Wire Probes - OCS System
Compatible
• FM Approved for Hazardous
(Classified) Locations
Part No.
890-111-01
890-111-02
890-111-03
6
Description
OCS Optic Overfill Probe 7.40 inch
OCS Optic Overfill Probe 11.69 inch
OCS Optic Overfill Probe 15.69 inch
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
179
Section A
Petroleum Trailer Parts
EBW
Three Wire System
EBW Transport Systems commitment
to quality does not stop at the loading
rack or at the service station. EBW
Transport Systems commitment to
quality is with you and your
equipment twenty-four hours a day.
Features and Benefits
• Probes are compatible with all
existing EBW Controllers
• Operating Temperature
-40 degF - +160 degF
• Optical Sensor for quickest and
most reliable product sensing
• Three-Wire Probes - OCS System
Compatible
• FM Approved for Hazardous
(Classified) Locations
Part No.
890-111-04
Description
Three wire Optic Overfill Probe w/Flange 6.25 inch
Three Wire System
EBW Transport Systems has spared
no expense during the development
and testing of the OCS Optic Overfill
and Optic Retained Product probes.
EBW Transport Systems is dedicated
to providing the highest quality
overfill protection solutions available
in the World. These probes and
controllers are rivaled by no one in
the industry.
Features and Benefits
• Probes feature surface mount military
spec electronic components
• Operating Temperature
-40 degF - +160 degF
• Three-Wire Probes - OCS System
Compatible
• FM Approved for Hazardous
(Classified) Locations
Part No.
890-121-A
890-121-01
All OCS Optic Probes are FM
approved for Hazardous (Classified)
Locations. FMRC Class No. 3600 Electrical Equipment for Use in
Hazardous (Classified) Locations
General Requirements.
FMRC Class No. 3610 - Intrinsically
Safe Apparatus for Use in Class 1, II
and III Division 1 Hazardous
(Classified) Locations.
FMRC Class No. 3611 - Electrical
Equipment for Use in Class I,
7
180
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
Description
Three Wire Retained Product Probe w/Coupling
Three Wire Optic Retained Product Probe Only
Division 2, Class II, Division 2 and
Class III, Division 1 and 2 Hazardous
Locations.
Probe Holders
Advantages
908-262-01
908-263-01
Anodized aluminum construction.
1/2" NPT connection ports.
2" NPT male thread.
2" NPT cast lock nut.
Tall or short cover.
O-ring sealed.
Three bolt locking ring.
For use with all EBW and
competition probes.
Section A
Petroleum Trailer Parts
•
•
•
•
•
•
•
•
Probe kits are available with Two-Wire Probes or Three-Wire Probes. Kits are standard with
the 908-263-01 probe holder with a cast lock nut. Two styles are available: a Three-Wire Optic
Probe (890-257-01) or a Two-Wire Optic Probe (890-257-02).EBW
908-208-01
890-257-02
TRANSPORT
Two-Wire Probe
SYSTEMS
Optic Control System
Single Socket Solutions
Part Number
Description
890-257-02
Probe Holder with Two-Wire Probe
908-262-01
• Ease of installation.
Probe Holder with 2" Male NPT Thread
908-262-02
• Moisture proof.
Probe Holder with 2" Male
NPT Thread,
Tall
Cap These sockets are moisture proof and have stainless steel contact pins
overfill
monitor
plugs.
Advantages
Single Sockets are manufactured in accordance to API RP1004 and are compatible with all
in Lock
a bakelite
• Stainless steel contact pins.
908-263-01
Probe Holder with 2" Cast
Nut housing. Hard-coated aluminum faceplates and J-Slots are long-lasting and come
standard with black plastic caps. Optic, Thermistor and Float styles are available.
• Produced in accordance
with
908-208-01
Tall
Probe Holder Cover
API 1004.
• Available in all three API standard
socket configurations.
908-221-01
908-230-01
908-211-01
54
Part Number
Description
908-211-01
Thermistor Socket with Plastic Cap
908-221-01
Optic Socket with Plastic Cap
908-230-01
7-Pin Socket with Plastic Cap
908-119-01
Plastic Cap Only
908-110-01
Thermistor Conversion Kit
908-120-01
Optic Conversion Kit
908-231-01
7-Pin Conversion Kit
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
181
Section A
Petroleum Trailer Parts
Scully
08687 5-wire monitor
09109 Intellicheck II monitor
08560 Ground bolt
08274 Ground ball
67151 SJ-8Bs
12.21.1999 12:41 PM
Page 1
08836 TIM chip
Scully Thermistor Socket
Overfill Prevention For Road Tankers with 1-8 Compartments
67151 SJ-8Bs
12.21.1999 12:41 PM
Page 1
Description
07720 - Thermistor socket
The Scully Thermistor socket is used to
07974 - Optic socket
connect up to 8 tanker mounted thermistor
sensors to the Scully Biclops® III Overfill
Prevention Monitor via the Scully Sculcon®
Plug and Cable Unit.
Scully Thermistor Socket
Overfill Prevention For Road Tankers with 1-8 Compartments
Description
• Lightweight polyvinyl cap is included
Scully Thermistor Socket with Polyvinyl Cap
• Use with Scully thermistor sensors
The Scully
Thermistor
is used
• Available
with integral
brakesocket
interlock
switchto
connect
up to 8 tanker mounted thermistor
for top loading
• Rugged construction
• Pins for tanker earthing incorporated
• Incorporates electronic dummy for tankers with
less than eight compartments
• Easy installation on tanker chassis
• Accomadates top and bottom loading
Scully Thermistor Socket with Polyvinyl Cap
182
sensors to the Scully Biclops® III Overfill
Prevention Monitor via the Scully Sculcon®
• Optional mounting bracket with threaded
Plug and Cable Unit.
captive plate and bolts for top loading socket
• Optional integral pressure switch for
vapor recovery
• Lightweight polyvinyl cap is included
Emergency Shutdown
Principle of Overfill Prevention
• Available
integral brake interlock switch
Systemwith
Components
Spartanburg,
SC
Phone:
800.828.6555
Fax:
864.583.1550
• Use with Scully thermistor sensors
for
top loading
Scully
Scully Sensor
Cincinnati, OH - Phone:
866.879.9773 - Fax: 513.860.1355
Control
Main Power
• Rugged construction
• Pins
for tanker earthing incorporated
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
Monitor
• Incorporates
electronic dummy for tankers with • Optional mounting bracket with threaded
www.littlejohninc.com
Scully
less than eight compartments
Tanker
• Easy installation on tanker
chassis
• Accomadates top and bottom loading
Junction plate and Output
captive
bolts for top Terminal
loading socket
Signal
Automation
Scully
Box
System
• Optional integral pressure switch
for
Socket & Plug
Connection
Cable
vapor recovery
09209 5-wire probe
09409 2-wire probe
FT103 CheckMate
monitor
Section A
Petroleum Trailer Parts
FloTech
FT208 5-wire monitor
FT100 5-wire probe
FT150 2-wire blk/wht
FT201 2-wire blk/red
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
183
Section A
Petroleum Trailer Parts
Civacon
Model #3100 Liberty On Board Monitor
for use with 5-Wire Optic Sensors
Replacement Par t s
Rev. A, March 2006
8
7
3
5
2
1
9
4
6
10
ITEM
1
2
3
4
5
6
7
8
9
10
184
PART NUMBER
C40015M
C40097M
C40104A
3150-3150
C40180M
D40006A
H50086M
H50114M
H50623M-2
H50070M
DESCRIPTION
GASKET (ENCLOSURE, OBM)
WINDOW (ENCLOSURE, OBM)
COVER (ENCLOSURE, OBM)
ASSEMBLY MODULE (OPTIC OBM)
NAME PLATE (3100 MONITOR)
BASE (ENCLOSURE, OBM)
WASHER (1/4" SPLIT, S.S.)
SCREW (1/4-20 X 3/4, S.S.)
SCREW (#6-32 X 3/8 S.S. W/LOCK WASHER)
PIPE PLUG (1/2" N.P.T.)
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
QTY.
1
1
1
1
1
1
6
6
4
1
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061
4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
Section A
Petroleum Trailer Parts
Civacon
Model #3202 ROM II On Board Monitor
for use with Civacon 2-Wire Optic Sensors
Replacement Par t s
Rev. 0, January 2003
8
7
3
2
1
9
12
4
5
6
11
ITEM
1
2
3
4
5
6
7
8
9
10
11
12
10
PART NUMBER
C40015M
C51426M
C40104APC
3252
H51425M
D40006APC
H50086M
H50114M
H50623M-2
H50452
H50070M
H51642M
DESCRIPTION
GASKET (ENCLOSURE, OBM)
WINDOW (ENCLOSURE, OBM)
COVER (ENCLOSURE, OBM, GRAY POWDERCOATED)
ASSEMBLY MODULE (OPTIC OBM)
NAME PLATE (APPROVALS, ROM II)
BASE (ENCLOSURE, OBM, GRAY POWDERCOATED)
WASHER (1/4" SPLIT, S.S.)
SCREW (1/4-20 X 3/4, S.S.)
SCREW (#6-32 X 3/8 S.S. W/LOCK WASHER)
SWITCH ASSEMBLY (1/2" N.P.T.)
PIPE PLUG (1/2" N.P.T.)
JUMPER STRIP (10 POSITION)
QTY.
1
1
1
1
1
1
6
6
4
1
1
1
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
PHONE: (816) 741-6600 • (888) 526-5657
• Fax:OH
(816)
741-1061
Cincinnati,
- Phone:
866.879.9773 - Fax: 513.860.1355
Chicago,
- Phone: 800.621.7131 - Fax: 708.442.9229
4304 Mattox Road • Kansas City, MO
64150 •ILwww.civacon.com
www.littlejohninc.com
185
Section A
Petroleum Trailer Parts
Civacon
PARTS BREAK DOWN
4100-4100 Optic Socket API Pattern for Optic Output
ITEM
PART NUMBER
1
C40011M2
2
D40103AH
DESCRIPTION
CONTACT BLOCK
2
FACEPLATE, OPTIC
QTY.
ITEM
PART NUMBER
1
13
C51503M2
14
2
1
H50618M
1,2
DESCRIPTION
QTY.
LABEL, TECH ASSISTANCE
1
GROUND WIRE
1
DUST CAP, BLUE
1
CABLE
1
3
D40100A
BODY
1
15
H50025M
4
H50616M2
CONTACT, BUTTON
6
16
H50288M1,2
5
H50064M
2
GASKET
1
17
H50290M
1,2
RIVET
1
6
H50617M2
INSERT
4
18
H50292M1,2
WASHER
1
7
H50074M2
SCREW, #6-32 1/2”
1
19
H50293M1,2
LOGO WASHER
1
SCREW, #6-32 3/8”
1
NAME PLATE
1
8
H50623M-2
9
H50107M2
2
10
H50108M
11
H50250M2
12
2
H50291M
2
SCREW, 5/16-18 3/4”
2
WASHER, 5/16 SS
2
4150-4150
REPAIR KITS
DUST CAP
SPACER
1
4110-4110
FACE PLATE KIT
1 - Included in 4150-4150, 2 - Included in 4110-4110
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061
4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
186
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
Rev. +, July 2009
Section A
Petroleum Trailer Parts
Civacon
Model #4401 Socket
API pattern for thermistor output
Replacement Par t s
Rev. A, March 2006
1
10
11
12
8
2
9
6
4
7
13
14
5
3
ITEM
PART NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
N/A
4450
C40011M
D40100A
D40102AH
H50064M
H50074M
H50136M
H50108M
H50250M
H50291M
H50616M
H50617M
H50618M
H50623M-2
4411
DESCRIPTION
DUST CAP (SOCKET ASSY, GREEN)
BLOCK (CONTACT, SOCKET, 10 HOLE)
BODY (SOCKET, MOLDED)
FACEPLATE (SOCKET, THERMISTOR)
GASKET (SOCKET BODY, NEOPRENE)
SCREW (#6-32 X 1/2, CRS FCS, S.S.)
NAME PLATE (4400 API THERMISTOR SOCKET)
SCREW (5/16-18 X 3/4 S.S.)
WASHER (5/16 S.S.)
SPACER (RND, S.S.)
CONTACT (BUTTON, SOCKET)
INSERT (BUTTON, SOCKET)
ASSY. (WIRE, GROUND, SOCKET)
SCREW (#6-32 X 3/8, CRS PAN, S.S.)
FACE PLATE KIT (INCLUDES ALL ITEMS EXCEPT ITEM 3)
QTY.
1
1
1
1
1
1
1
2
2
1
8
4
1
1
1
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
PHONE: (816) 741-6600 • (888) 526-5657
• Fax:
741-1061
Cincinnati,
OH(816)
- Phone:
866.879.9773 - Fax: 513.860.1355
4304 Mattox Road • Kansas City, MO
64150IL•-www.civacon.com
Chicago,
Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
187
Section A
Petroleum Trailer Parts
Civacon
Model #1051-007 ROM
Optic Sensor (2-Wire 2" NPT)
Replacement Par t s
Rev. A, March 2006
4
13
4 1/16"
2
9
7
3 1/4"
11
3
12
14
8
1/2" NPT
5
10
3 5/16"
6
15
1
5" (MIN.)
7" (MAX.)
188
ITEM
PART NUMBER
1
N/A
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1351-007
1355-1355
C40030A
D40023A
H50066M
H50080M
H50083M
H50086M
H50088M
H50153M
H50276M
H50279M
H50371M
H50476M
H50524M
H50070M
DESCRIPTION
OPTIC SENSOR
PROBE HOUSING (INCLUDES ALL ITEMS EXCEPT ITEMS 1 & 13)
UPPER HOUSING CAP
LOWER HOUSING BODY
DRIVE SCREW
O-RING (BODY SENSOR TUBE)
LOCK NUT (2" N.P.T.)
WASHER (1/4" SPLIT, S.S.)
O-RING (PROBE ADJUSTING SCREW)
SCREW (1/4-20 X 1/2 STL, FIL, S.S.)
GASKET (BASE SENSOR)
O-RING (CAP SENSOR)
PROBE ADJ. SET SCREW (1/4-20 X 27/32 STL, FIL, S.S.)
NAME PLATE (1050 SENSOR)
GREEN GROUNDING SCREW (#8-32 X 3/8 CMB, BND, DC)
PIPE PLUG (1/2" N.P.T.)
QTY.
1
N/A
1
1
2
1
1
2
1
2
1
1
1
1
1
1
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
www.littlejohninc.com
Section A
Petroleum Trailer Parts
Civacon
Model #1110 Optic Sensor
(5 Wire 2" NPT)
Replacement Par t s
Rev. 0, January 2003
4
12
4 1/16"
2
9
7
3 1/4"
11
3
13
14
8
1/2" NPT
5
10
3 5/16"
6
15
1
5" (MIN.)
7" (MAX.)
ITEM
PART NUMBER
1
N/A
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1300
1355
C40030A
D40023A
H50066M
H50080M
H50083M
H50086M
H50088M
H50153M
H50276M
H50279M
H50284M
H50371M
H50524M
H50070M
QTY.
DESCRIPTION
OPTIC SENSOR
PROBE HOUSING (INCLUDES ALL ITEMS EXCEPT ITEMS 1, 4 & 12)
UPPER HOUSING CAP
LOWER HOUSING BODY
DRIVE SCREW
O-RING (BODY SENSOR TUBE)
LOCK NUT (2" N.P.T.)
WASHER (1/4" SPLIT, S.S.)
O-RING (PROBE ADJUSTING SCREW)
SCREW (1/4-20 X 1/2 STL, FIL, S.S.)
GASKET (BASE SENSOR)
O-RING (CAP SENSOR)
NAME PLATE (1110 SENSOR)
PROBE ADJ. SET SCREW (1/4-20 X 27/32 STL, FIL, S.S.)
GREEN GROUNDING SCREW (#8-32 X 3/8 CMB, BND, DC)
PIPE PLUG (1/2" N.P.T.)
1
N/A
1
1
2
1
1
2
1
2
1
1
1
1
1
1
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
PHONE: (816) 741-6600 • (888) 526-5657
• Fax:OH
(816)
741-1061
Cincinnati,
- Phone:
866.879.9773 - Fax: 513.860.1355
Chicago,
- Phone: 800.621.7131 - Fax: 708.442.9229
4304 Mattox Road • Kansas City, MO
64150 •ILwww.civacon.com
www.littlejohninc.com
189
Section A
Petroleum Trailer Parts
Civacon
Model #1550 Thermo-Optic
Quick Start Probe (2-wire 2" NPT)
Replacement Par t s
Rev. 0, January 2003
4
13
4 1/16"
2
9
7
3 1/4"
11
3
12
14
8
1/2" NPT
5
10
3 5/16"
6
15
1
5" (MIN.)
7" (MAX.)
190
ITEM
PART NUMBER
1
N/A
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1650-1650
1355-1355
C40030A
D40023A
H50066M
H50080M
H50083M
H50086M
H50088M
H50153M
H50276M
H50279M
H50371M
H50421M
H50524M
H50070M
DESCRIPTION
OPTIC SENSOR
PROBE HOUSING (INCLUDES ALL ITEMS EXCEPT ITEMS 1 & 13)
UPPER HOUSING CAP
LOWER HOUSING BODY
DRIVE SCREW
O-RING (BODY SENSOR TUBE)
LOCK NUT (2" N.P.T.)
WASHER (1/4" SPLIT, S.S.)
O-RING (PROBE ADJUSTING SCREW)
SCREW (1/4-20 X 1/2 STL, FIL, S.S.)
GASKET (BASE SENSOR)
O-RING (CAP SENSOR)
PROBE ADJ. SET SCREW (1/4-20 X 27/32 STL, FIL, S.S.)
NAME PLATE (1550 SENSOR)
GREEN GROUNDING SCREW (#8-32 X 3/8 CMB, BND, DC)
PIPE PLUG (1/2" N.P.T.)
QTY.
1
N/A
1
1
2
1
1
2
1
2
1
1
1
1
1
1
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
www.littlejohninc.com
Section A
Petroleum Trailer Parts
Civacon
PARTS BREAK DOWN
4100-4100 Optic Socket API Pattern for Optic Output
ITEM
1
PART NUMBER
C40011M
2
2
DESCRIPTION
CONTACT BLOCK
QTY.
1
ITEM
13
PART NUMBER
C51503M
2
2
DESCRIPTION
LABEL, TECH ASSISTANCE
QTY.
1
2
D40103AH
FACEPLATE, OPTIC
1
14
H50618M
GROUND WIRE
1
3
D40100A
BODY
1
15
H50025M1,2
DUST CAP, BLUE
1
4
H50616M2
CONTACT, BUTTON
6
16
H50288M1,2
CABLE
1
5
H50064M2
GASKET
1
17
H50290M1,2
RIVET
1
6
H50617M
2
18
H50292M
1,2
WASHER
1
7
H50074M
2
H50293M
1,2
LOGO WASHER
1
8
H50623M-22
9
INSERT
4
SCREW, #6-32 1/2”
1
SCREW, #6-32 3/8”
1
H50107M2
NAME PLATE
1
10
H50108M2
SCREW, 5/16-18 3/4”
2
11
H50250M
2
WASHER, 5/16 SS
2
4150-4150
DUST CAP
H50291M
2
SPACER
1
4110-4110
FACE PLATE KIT
12
19
REPAIR KITS
1 - Included in 4150-4150, 2 - Included in 4110-4110
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061
4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
Rev. +, July 2009
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
191
Section A
Petroleum Trailer Parts
Civacon
Model #4401 Socket
API pattern for thermistor output
Replacement Par t s
Rev. A, March 2006
1
10
11
12
8
2
9
6
4
7
13
14
5
3
192
ITEM
PART NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
N/A
4450
C40011M
D40100A
D40102AH
H50064M
H50074M
H50136M
H50108M
H50250M
H50291M
H50616M
H50617M
H50618M
H50623M-2
4411
DESCRIPTION
DUST CAP (SOCKET ASSY, GREEN)
BLOCK (CONTACT, SOCKET, 10 HOLE)
BODY (SOCKET, MOLDED)
FACEPLATE (SOCKET, THERMISTOR)
GASKET (SOCKET BODY, NEOPRENE)
SCREW (#6-32 X 1/2, CRS FCS, S.S.)
NAME PLATE (4400 API THERMISTOR SOCKET)
SCREW (5/16-18 X 3/4 S.S.)
WASHER (5/16 S.S.)
SPACER (RND, S.S.)
CONTACT (BUTTON, SOCKET)
INSERT (BUTTON, SOCKET)
ASSY. (WIRE, GROUND, SOCKET)
SCREW (#6-32 X 3/8, CRS PAN, S.S.)
FACE PLATE KIT (INCLUDES ALL ITEMS EXCEPT ITEM 3)
QTY.
1
1
1
1
1
1
1
2
2
1
8
4
1
1
1
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
www.littlejohninc.com
Section A
Petroleum Trailer Parts
Civacon
PARTS BREAK DOWN
4820 Dual Socket
ITEM
PART NUMBER
1
C40151A-3
2
2
C40151A-41
3
C40011M1,2
4
1,2
H50073M
1,2
5
H50401M-02
6
H50290M3,4
7
8
DESCRIPTION
QTY.
ITEM
PART NUMBER
DESCRIPTION
QTY.
“J” SLOT SOCKET - 3
1
15
D52550M
BASE
1
“J” SLOT SOCKET - 4
1
16
H52551M
LABEL
1
CONTACT BLOCK
2
17
H52552M
PLATE
1
SCREW, #8-32 3/8”
8
18
H50086M
LOCK WASHER, 1/4”
6
WASHER, #8
8
19
9485
WASHER, 1/4”
6
RIVET
2
20
H52553M
GASKET
1
H50292M
3,4
WASHER
2
21
H50114M
SCREW, 1/4-20 3/4”
6
H50293M
3,4
LOGO WASHER
2
22
H50070M
PIPE PLUG
1
3,4
CABLE
2
DUST CAP, GREEN
1
DUST CAP, BLUE
1
C40151-THERM
REPL. THERMISTOR FACE PLATE
15’
C40151A-OPTIC
REPL. OPTIC FACE PLATE
STRAIN RELIEF
1
4150-4150
DUST CAP, BLUE
GASKET
2
4450-4450
DUST CAP, GREEN
9
H50288M
10
H50065M4
11
H50025M
3
12
97701
13
H50221M
14
H52479M1,2
CABLE, 7 COND. 20 GA BK
REPAIR KITS
1 - Included in C40151-THERM, 2 - Included in C40151A-OPTIC, 3 - Included in 4150-4150, 4 - Included in 4450-4450
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061
4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
Rev. +, July 2009
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
193
Section A
Petroleum Trailer Parts
Civacon
5-Wire Optic Level Sensor
Rev. A, Mar 2010
Civacon introduces our new
5-Wire Optic Sensor. The new
sensor and housing includes
digital technology and improved
design features. This sensor is
the perfect fit for your overfill
detection needs.
Optic overfill sensors detect the presence of liquid at a preset
level. The new Civacon 5-Wire Sensor is fully compatible
with all our current 5-Wire Sensors and Monitors, as well as
all industry standard signal formats. These new Sensors
feature an exclusive, digital electronic circuitry design that will
work directly with 5-Wire loading racks when wired directly to
a blue WOGA1 or SAE J-560 style “optic” socket, as well as
with all Onboard Monitors like our Civacon Liberty™.
The new Civacon 5-Wire Sensors are a direct replacement
for our 5-Wire Liberty™ optic sensors. The new 5-Wire output
signal is compatible with the industry standard signal format,
which makes it the right choice for any of your 5-Wire overfill
detection sensor applications.
All of the features & benefits of these new sensors are also
available in our new 2-wire sensor version as well (see
separate data sheet).
Overfill Features
• 5-Wire Probe output signal is compatible with the industry
standard output format
• New digital electronics with new temperature stabilized friendly
potting
• Zero glue or adhesive construction for wide chemical compatibility
• Still the industries best single flat surface optic prism design!
• Recessed, protected one piece molded, all glass Pyrex® prism
• Completely new Housing and Cap design
• Molded non-corrosive cap with captive seal means no tools
required for access, or adjustment of probe
• Tamper Evident Tab on Cap lets you add a seal to prevent
Sensor Tube
Retaining Spring.
Squeeze ends
together to adjust
sensor height.
sensor height tampering (sensor can not be adjusted externally)
• Housings and Replacement Sensors are 100% compatible with all
previous Civacon 5-Wire models
• Approved to North American, Europe (ATEX) and World (IECEX)
Tamper Evident Tab
1. WOGA (Western Oil and Gas Association), the former name for the
Western States Petroleum Association (WSPA)
• Operating Temperature -40º F (-40º C) to 160º F (71.1º C)
Storage Temperature -70º F (-56.6º) to 280º F (137.7º C)
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061
4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
194
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
5-Wire Optic Level Sensor
Section A
Petroleum Trailer Parts
Civacon
Product Specifications
Product Number
1112-007, 0012 or 0018 (See Below)
Sensing Length Adjustability
See Drawing
Product Range
Refractive Index 1.37 to 1.60
Viscosity of less that 1000 SSU
Electrical Leads
22 ga. Stranded Wire 26” Long
Weight
1.15 lbs. (0.521 kg)
Materials
Sensor Cap - Glass Filled Nylon
Cap O-ring - Silicone
Sensor Housing - Aluminum
Mounting O-ring - Viton
Locking Nut - Plated Steel
Sensor Shaft - Aluminum
Prism - Pyrex® Glass
Prism O-ring - Fluorosilicon
Snap Ring - Stainless
Approvals
North American
Europe (ATEX)
World (IECEX)
Temperature Range
Operating Temperature -40º F (-40º C) to 160º F (71.1º C)
Storage Temperature -70º F (-56.6º) to 280º F (137.7º C)
**Special length sensors are available upon request
REFERENCE CHART
5-Wire
Part #
Old Civacon
Part #
Description
1112-007
1110-1110
Optic Overfill Sensor, 5-Wire, 2” NPT Parallel Port Housing, 7”
1112-0012
1110-0012
Optic Overfill Sensor, 5-Wire, 2” NPT Parallel Port Housing, 12”
1112-0018
1110-0018
Optic Overfill Sensor, 5-Wire, 2” NPT Parallel Port Housing, 18”
1302-007
1300-1300
Replacement Optic Overfill Sensor, 5-Wire, No Housing, 7”
1302-0012
1300S-0012
Replacement Optic Overfill Sensor, 5-Wire, No Housing, 12”
1302-0018
1300S-0018
Replacement Optic Overfill Sensor, 5-Wire, No Housing, 18”
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061
4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
195
Section A
Petroleum Trailer Parts
Civacon
2-Wire Socket Optic Level Sensor w/ Housing
Rev. C, MAY 2010
70000PA
Civacon introduces our new
Socket Optic Overfill Sensor.
A completely new sensor and
housing with enhanced
technology and design features.
The non– polarized digital
electronic circuitry design is a
perfect fit for all your overfill
detection needs.
Optic overfill sensors detect the presence of liquid at a preset
level. The new Civacon Socket Sensor is fully backward
compatible with our current Quick-Start™ Sensors and
Monitors, as well as all industry standard signal formats.
These new Socket Sensors feature an exclusive, nonpolarized digital electronic circuitry design that will work
directly with 2-wire (green plug) loading racks when wired
directly to a green “thermistor” socket, as well as with all
on-board Monitors like the Civacon ROM II. The sensor’s
non-polarized electronic design means not having to worry
about the sensor’s wire color or polarity anymore. The two
grey wires can be wired as either signal or ground
interchangeably. You can not wire it wrong!
The new Civacon Socket Sensors are a direct replacement
for our 2-wire, Quick-Start™ (white & black wire) optic
sensors. With their 2-wire industry compatible signal format,
they are a perfect choice for your 2-wire overfill detection
sensor applications.
Overfill Features
• 2-Wire Socket Sensor will work with ROM II and Quick Start
2-Wire Systems
• Two grey wires for non-polarized connection as signal or ground
• New digital electronics with extended temperature-stabilized
potting
• Dual o-ring seals in housing for improved sensor shaft-to-housing
sealing
• Zero glue or adhesive construction for wide chemical compatibility
• Still the industries best single flat surface optic prism design!
• Recessed, protected one piece molded, Borosilicate glass prism
The features & benefits of these new sensors are also
available in our new 5-wire sensor version as well.
(call us for more details)
• Completely new Housing and molded non-corrosive Cap design
• No tools required for access, or adjustment of probe
• Approved to North American, Europe (ATEX) and World (IECEX)
Standards
Sensor Tube
Retaining Spring.
Squeeze ends
together to adjust
sensor height.
• Operating Temperature -40º F (-40º C) to 160º F (71.1º C)
Storage Temperature -70º F (-56.6º) to 280º F (137.7º C)
• OPTIONAL: Tamper Evident Tab on cap lets you add a seal to
Tamper Evident Tab
prevent sensor height tampering (sensor can not be adjusted
externally)
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061
4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
196
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
Product Specifications
Product Number
Materials
1552G-007, 0012 or 0018 (See Below) Sensor Cap - Glass-Filled Nylon
1652G-007, 0012 or 0018 (See Below) Cap O-ring - Silicone
Sensor Housing - Aluminum
Sensing Length Adjustability
Mounting O-ring - Viton
See Drawing
Locking Nut - Plated Steel
Sensor Shaft - Aluminum
Product Range
Prism - Borosilicate Glass
Refractive Index 1.37 to 1.60
Prism O-ring - Fluorosilicon
Viscosity of less that 1000 SSU
Retaining Ring - Stainless Steel
Electrical Leads
Two 18 ga. Stranded Wire
26” Long (Grey in Color)
Weight
1.15 lbs. (0.521 kg) (with housing)
Section A
Petroleum Trailer Parts
2-Wire Socket Optic Level Sensor
w/ Housing
Civacon
Approvals
North America
Europe (ATEX)
World (IECEX)
Temperature Range
Operating Temperature -40º F (-40º C) to 160º F (71.1º C)
Storage Temperature -70º F (-56.6º) to 280º F (137.7º C)
REFERENCE CHART
Socket Optic
Sensor Part #
Old Quick Start
Part #
Description
1552G-007
1551-007
Optic Overfill Sensor, 2-Wire, 2” NPT Parallel Port Housing, 7”
1552G-0012
1551-0012
Optic Overfill Sensor, 2-Wire, 2” NPT Parallel Port Housing, 12”
1552G-0018
1551-0018
Optic Overfill Sensor, 2-Wire, 2” NPT Parallel Port Housing, 18”
1652G-007
1651-007
Replacement Optic Overfill Sensor, 2-Wire, No Housing, 7”
1652G-0012
1651-0012
Replacement Optic Overfill Sensor, 2-Wire, No Housing, 12”
1652G-0018
1651-0018
Replacement Optic Overfill Sensor, 2-Wire, No Housing, 18”
1455-1455
1355-1355
2” NPT Parallel Port Housing w/ Cap
12214
N/A
Tamper Evident Tab Kit
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061
4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
197
Section A
Petroleum Trailer Parts
Civacon
198
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
Section A
Petroleum Trailer Parts
Civacon
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
199
Section A
Petroleum Trailer Parts
Civacon
200
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
Section A
Petroleum Trailer Parts
Civacon
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
201
Section A
Petroleum Trailer Parts
Scully
202
Scully Intellicheck 2 Monitor
Part Number
Model
09109
Overfill Monitor
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
Item
Part
Number
Description
1
09132
Cover assy...
2
32600
Cover
3
32601
Window
4
31787
Cover
gasket
5
50151
Screw
6
51122
Lock washer
7
09111
Module
8
32599
Base
9
31820
Switch
10
50740
31616
Pipe plug
Fuse holder
11
31842
Standoff
Scully Load Anywhere® System
Complete Overfill Prevention Loading Rack Compatibility
Featuring Dynacheck ® - Automatic and Continuous Self-Checking Circuitry
Section A
Petroleum Trailer Parts
Scully
Scully truck mounted control monitor and sockets
The Scully Load Anywhere® Overfill Prevention System offers the maximum safety in tank truck
loading operations. System components include the Scully Load Anywhere Control Monitor, Optic Sensors
and Optic, Thermistor or Float Sockets. The Scully Load Anywhere System offers all these advantages:
• Durable construction for long-lasting
• Complete compatibility with Scully Optic
dependability.
and Thermistor Rack Control Monitors the #1 choice of over 90% of all bottom
Optic sensors
Load Anywhere® System• Replacement
Partsthat defeat fogging.
loading terminals in the United States.
Description
Part #
• Resistance to a wide range of temperatures.
• Dynacheck ® - automatic and continuous
Load Anywhere Control Monitor only
08687
• Easy installation with step by step instructions.
self-checking circuitry for maximum safety
Load Anywhere Control Module only
08563
through
electronic
Load Anywhere
Retrofitmonitoring.
Kit for Old Style Monitor, including New• Module
and Face
PlateinAssembly
08518
The best
service
the business with toll-free
Load Anywhere
compartment
cover
assembly
• Over
30 years6 of
field-proven
performance
Optic sensor with holder, 7"
making
Scully the #1 choice worldwide.
•
07894
• A complete system with monitor, sensors,
Optic sensor only, 7"
21500
sockets and installation kit.
On/Off
dashboard
mounted,
push-pull power control switch
58000
No
manual
checks
are needed.
Complete Installation kit with 100' Scully cable, 16 cable fittings, 30 crimp-on connectors, 1 on/off switch,
08309
1/4 ampere in-line fuse and 1 socket cleaner
Optic/Thermistor installation kit with 100' Scully Cable, 16 cable fittings, 30 crimp-on connectors
08399
100' of special Scully cable
22056
16 cable fittings
27555
30 crimp-on connectors
22255
Socket cleaner only
07811
Load Anywhere Installation and Service
08679
® Video
See our IntelliCheck Brochure for the latest in Tank Truck Overfill Prevention
Optic sensor with holder, 12"
08698
and Retained Product Monitoring.
Optic sensor only, 12"
08758
Description
Socket Replacement Parts
Setting
New Standards In Safety
Housing for all socket models
Blue Vinyl Cap, SJ-6W, SJ-6SO, SJ-6X Sockets
Green Vinyl Cap, SJ-6S, SJ-6 Sockets
Scully Signal Company, 70 Industrial Way, Wilmington, MA 01887 U.S.A.
Vinyl
Cap, SJ-F, SJ-6F Sockets
Tel (617) 692-8600,Red
Fax (617)
692-8620
Contact assembly for SJ-6S socket
Contact assembly for SJ-6SO & SJ-6W socket
Contact assembly for SJ-F socket
Contact assembly for SAE J560 sockets
Housing gasket for all socket models
Replacement single pin and screw for all sockets
60671
08712
trouble-shooting and maintenance assistance.
Part #
21810
08575
08574
08576
20757
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
21771
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
21104
www.littlejohninc.com
27450
20628
07783
203
Section A
Petroleum Trailer Parts
Scully
1/2" NPT
CONDUIT ENTRY
2 HOLES
2.12" (54)
1/2" NPT
CONDUIT ENTRY
2 HOLES
2.12" (54)
Ø.26" ( Ø 6.6)
THRU HOLE ON
Ø 4.25" (Ø 108)
BOLT CENTER
6 MTG HOLES
EQ. SPACED
3.62"
(92)
3.62"
(92)
2" NPT
VITON, GASKET
LOCK NUT
5.19" TO 6.93"
(132 TO 176)
5.19" TO 6.38"
(132 TO 162)
Ø5.12"
(Ø130)
SP-TO/MHC
SP-TO/MHCF
Ø.26" ( Ø 6.6)
DRILL POINT SPOT
(118º) ON A
HOLDER MOUNTING
SP-TO/MHCF
Ø 4.50" (Ø114)
BOLT CENTER
4 PLACES
Technical Specifications
Operating Temperature Range
-40° F to +140° F (-40° C to +60° C)
Product Range
Gasoline blends and light fuel oils
Exposed Materials
Aluminum, zinc, borosilicate (Pyrex®) glass, epoxy, conductive
nylon and Viton® seals
Detection Level and Size
The detection level is adjustable. Refer to sensor outline drawing
above, shown for 7" shaft length.
Level Repeatability
±1/16" (1 mm)
Electrical Leads
18" (45 cm) long, 18 AWG (0.82 mm2)
Cable Entry
Two holes, 1/2" NPT threads
Approvals
The sensor is intrinsically safe for mounting in Class I,
Division 1, Groups C & D Hazardous location in accordance
with Scully Control unit approval ratings
Ordering Information
Model
Description
Shaft Length
Part Number
SP- FU/MHC
Five-wire optic sensor, 2" NPT holder, 2-1/8" standard cap
7" (175mm)
12" (300mm)
15" (375mm)
09208
09213
09216
SP- FU/MHCF
Five-wire optic sensor, flanged holder, 2-1/8" standard cap
7" (175mm)
12" (300mm)
09207
09212
Model
Description
SP-FU
SP-FU
SP-FU
Five-wire optic sensor (without holder)
Replacement Parts
Part Number
7" (175mm)
12" (300mm)
15" (375mm)
Shaft O-ring
09209
09214
09217
08577
SP-MHC
2" NPT Threaded Holder Only
09065
SP-MHCF
Flanged Holder Only
08265
Mounting Gasket for SP-MHC Holder
20893
Mounting Lock Nut for SP-MHC Holder
57044
Mounting Gasket for SP-MHCF Holder
21451
Cap O-ring
20766
Short Cap (SC), height 1.38" (35mm)
21583
Medium (Standard) Cap (MC), height 2.13" (54mm)
20888
Cap screw
50652
Cap screw spring washer
51122
Biclops, Dynacheck, Dynamic Self-Checking, Faylsafe, Load Anywhere, IntelliCheck, Intellitrol, IntelliTank, Intelliview, Maxsafety, MulteCept, Sculcon, Scultrol, Scully,
R.S.V.P., TABS and Scully V.I.P. are registered trademarks of Scully Signal Company.
Viton is a registered trademark of DuPont.
Specifications are subject to change without notice.
Corporate Headquarters
Scully Signal Company
S
O 90
I
0
scully
70 Industrial Way
Wilmington, MA 01887
Tel: (800) 272-8559 • (617) 692-8600
Fax: (617) 692-8620
email: sales@scully.com • www.scully.com
1
IS
204
© Spartanburg,
Scully Signal Company.
SC - Phone: 800.828.6555 - Fax: 864.583.1550
Printed
in the U.S.A.
Cincinnati,
OH - Jan2000/60678revB
Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
N
Y
G
RE
T
E
RE
D
M
CO
P
A
1/2" NPT
CONDUIT ENTRY
2 HOLES
2.12" (54)
1/2" NPT
CONDUIT ENTRY
2 HOLES
2.12" (54)
Ø.26" ( Ø 6.6)
THRU HOLE ON
Ø 4.25" (Ø 108)
BOLT CENTER
6 MTG HOLES
EQ. SPACED
3.62"
(92)
3.62"
(92)
Section A
Petroleum Trailer Parts
Scully
2" NPT
VITON, GASKET
LOCK NUT
5.19" TO 6.93"
(132 TO 176)
5.19" TO 6.38"
(132 TO 162)
Ø5.12"
(Ø130)
SP-TO/MHC
SP-TO/MHCF
Ø.26" ( Ø 6.6)
DRILL POINT SPOT
(118º) ON A
HOLDER MOUNTING
SP-TO/MHCF
Ø 4.50" (Ø114)
BOLT CENTER
4 PLACES
Technical Specifications
Operating Temperature Range
-40° F to +140° F (-40° C to +60° C)
Product Range
Gasoline blends and light fuel oils
Exposed Materials
Aluminum, zinc, borosilicate (Pyrex®) glass, epoxy, conductive
nylon and Viton® seals
Detection Level and Size
The detection level is adjustable. Refer to sensor outline drawing
above, shown for 7" shaft length.
Level Repeatability
±1/16" (1 mm)
Electrical Leads
18" (45 cm) long, 18 AWG (0.82 mm2 )
Cable Entry
Two holes, 1/2" NPT threads.
Approvals
The sensor is intrinsically safe for mounting
in Class I, Division 1, Groups C & D
Hazardous location in accordance with
Scully Control unit approval ratings
Ordering Information
Model
Description
SP-TO/MHCF
Two-wire optic sensor, flanged holder, 35mm standard cap
SD-5C
5-Element Electronic Dummy
Model
Description
SP-TO/MHC
Shaft Length
Two-wire optic sensor, 2" NPT holder, 2-1/8" standard cap
Part Number
7" (175mm)
12" (300mm)
15" (375mm)
7" (300mm)
12" (300mm)
15" (375mm)
09408
09413
09416
09407
09212
09415
Employed on tank trucks with less than 6 compartments (8 in Canada) when not using IntelliCheck monitor
08298
Replacement Parts
SP-TO
SP-MHC
SP-MHCF
Shaft Length
Two-wire optic sensor (without holder)
7" (175mm)
12" (300mm)
15" (375mm)
Shaft O-ring
2" NPT Threaded Holder Only
Part Number
09409
09414
09417
08577
09065
Flanged Holder only
08265
Mounting Lock Nut for SP-MHC Holder
57044
Mounting Gasket for SP-MHC Holder
20893
Mounting Gasket for SP-MHC Holder
21451
Cap O-ring
20766
Short Cap (SC), height 1.38" (35mm)
21583
Medium (Standard) Cap (MC), height 2.13" (54mm)
20888
Cap screw
50652
Cap screw spring washer
51122
Biclops, Dynacheck, Dynamic Self-Checking, Faylsafe, Load Anywhere, IntelliCheck, Intellitrol, IntelliTank, Intelliview, Maxsafety, MulteCept, Sculcon, Scultrol, Scully,
R.S.V.P., TABS and Scully V.I.P. are registered trademarks of Scully Signal Company.
Viton is a registered trademark of DuPont.
Corporate Headquarters
Specifications are subject to change without notice.
Scully Signal Company
O 90
I
S
0
scully
70 Industrial Way
Wilmington, MA 01887
Tel: (800) 272-8559
• (617) 692-8600
Spartanburg,
SC - Phone: 800.828.6555 - Fax: 864.583.1550
Fax: (617) 692-8620
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago,
IL - Phone: 800.621.7131 - Fax: 708.442.9229
email: sales@scully.com
• www.scully.com
1
IS
© Scully Signal Company
Printed in the U.S.A. Jan2000/60715revB
N
Y
G
RE
T
E
RE
D
M
CO
P
A
www.littlejohninc.com
205
6 Compartment Load Anywhere Kit
08311
Scully Two-Wire Optic Socket
Advanced Optic Sensing
Section A
Petroleum Trailer Parts
Scully
Scully Optic Sensors are the sensingOverfill
device through
which Dynacheck
detects
the presence
of 1-8
liquidCompartme
Prevention
For Road
Tankers
with
product in the truck compartment. The sensors are set at a predetermined high level. Optic technology
insures no warm-up time and the ability to “see” liquid product. One sensor is mounted in each compartDescription
ment. The optic probes are adjustable at the time of installation for a variety of sensing
depths, and are
fitted with a permanent protector. Scully Optic Sensors are extremely resistant to fogging and handle a
The Scully Two-wire optic so
wide variety of temperatures and liquid products. Refer to technical
to connect up to 8 tanker mount
data sheet #60678 for more information.
optic sensors to the Scully Biclo
Prevention Monitor via the Scully
Plug and Cable Unit.
Durable, Reliable Connections
Scully Sockets are the vehicle mounted connectors for the rack plug.
Sockets feature lightweight vinyl protective caps to prevent socket corrosion by protecting the contact pins from dirt and moisture. A captive
cable attachment is also included to prevent loss. Sockets consist of
durable construction to withstand the rigors of road travel. Refer to
technical data sheet #60674 for more information.
Scully Two-Wire Optic
Socket with Polyvinyl Cap
Sockets
Information
• Suitable for Socket
ScullyOrdering
two-wire
optic sensors
Description (All sockets
includeto
the
vinyl
protective
• Caters
top
and
bottomcap)
loading
SJ-6S Thermistor, API•Standard
Rugged
construction
SJ-6 Thermistor, J560 Pattern
• Incorporates electronic dummy for tankers
Above are compatible with
the less
ST-6 and
Control Monitors
with
thanBiclops
eightRack
compartments
Easy
SJ-6SO Optic, Scully •
Pattern
installation on tanker chassis
• Lightweight
SJ-6W Optic, API Standard
• Available with integral brake inte
switch
for top
Socket
Part loading
#
• Optional07720
mounting bracket with
captive 07681
plate and bolts for top lo
• Optional integral pressure switch
vapor recovery
07973
• Pins for07974
tanker earthing incorpor
polyvinyl cap
SJ-6X Optic, J560 Pattern
08199
Above are compatible with the ST-35 and Biclops Rack Control Monitors
Principle of Overfill Prevention
Emergency Shutdown
System
Components
07788
SJ-F Float, Scully Pattern
Scully 08116
Control
switch adaptors
Above compatible with the Intellitrol™, ST-6, ST-35 and Biclops Rack Control Monitors with float
Monitor
SJ-6F Float, J560 Pattern
20770 - Faceplate Assy Thermistor
21790 - Faceplate Assy Optic
07811 - Socket Cleaner
Scully Sensor
Tanker
08574 - Green Cap
08575 - Blue Cap
Scully
Socket & Plug
Connection
Scully
Junction
Box
Output
Signal
Cable
T
A
S
From Pum
Loading Hose
Loading
Rack
Valve
Rack
Setting New Standards In Safety
206
Main Power
67155 Rev A
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
Scully Signal Company, 70 Industrial Way, Wilmington, MA 01887 U.S.A.
www.littlejohninc.com
Tel (617) 692-8600, Fax (617) 692-8620
Section A
Petroleum Trailer Parts
Scully
Universal Truck Tester
Tank Truck Overfill Prevention System Diagnostics
The Scully Universal Truck Tester is the most
advanced and comprehensive truck tester
available. It checks the operation of tank truck
overfill prevention, and self-proving grounding
systems. Complete diagnostics limit the
expense of downtime.
• Tests all Scully Optic and Thermister Overfill Sensors,
the Intellicheck® System, The Load Anywhere®
System and the Liquidometer TABSTM System output.
• Simultaneously tests all compartment sensors.
• The only tester which will check the operation of the
Ground Bolt and Ball.
• Shows a more accurate reading than any other tester
on the market with test results as either “Good, Poor,
or Fail” to easily diagnose service requirements.
• A poor reading alerts the driver that it may be time to
repair or replace the sensor in question.
• A variety of plug and cable assemplies are available
according to the socket needs of the user.
• Rustproof, weather resistant housing.
• Easy to read multicolored LED display.
Operation
Move the selector switch to the desired setting.
Connect the tester to the tank truck socket with the
appropriate plug and cable. The test results will be
shown clearly on the easy to read LED display.
Compatability
The tester is compatable with Scully Intellicheck®
Load Anywhere®, and independent Scully optic and
thermister tank truck sensors.
Technical Specifications
Power supply: ...............................................8”D” Cell, alkaline batteries
Battery access: .....................................Remove 2 screws in front panel
Operating temperature range: .............-13˚F to +113˚F (-25˚C to +45˚C)
Maximum number of compartments: .....................................................8
Dimensions: ...........................................................................8” x 6” x 4”
Weight (without batteries): ...............................................3.8 lbs (1.7Kg)
Ordering Information
Description
Part No.
Scully Universal Tester* ................................................................08938
PCAM, 10 Pole Scully Plug and Cable......................................... 08926
PCAM, 6 Pole WOGA Plug and Cable..........................................08927
PCAM, 7 Pole J560 Optic .............................................................08928
PCAM, 4 Pole Plug and Cable ..................................................... 08936
Adapter 7 Pole Scully Optic to J560..............................................07735
*Order appropriate plug & cable with tester. “D” size batteries not included.
• Runs on standard “D” size Alkaline batteries.
For further information and technical service, please
call Scully at (800) 272-8559.
Biclops, Dynacheck, Dynamic Self-Checking, Dynamic Self-Test, Faylsafe, Intellicheck, Intellitrol, Intelliview, Load Anywhere, Maxsafety, MulteCept,Scully,
Scultrol, Scul-Lock, Scul-Tel, Scul-Tite, TABS and V.I.P. are registered trademarks of the Scully Signal Company
Specifications are subject to change without notice
Worldwide Contact
Scully Signal Company
70 Industrial Way
Wilmington, MA 01887 USA
Tel: 1-800-272-8559 or (617) 692-8600
Fax: (617) 692-8620
email: sales@scully.com
www.scully.com
67252 Rev A
© Printed in U.S.A. February 1999
Setting New Standards In Safety
Scully Signal Company, 70 Industrial Way, Wilmington, MA 01887 U.S.A.
Tel (617) 692-8600, Fax (617) 692-8620
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
207
Section A
Petroleum Trailer Parts
Accessories
7523 Brass ground studs
3231 Watertite connections
Harness Wire
100’ or 1000’ rolls
208
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
Diagrams
Three Wire Diagrams
Section A
Petroleum Trailer Parts
OCS Guide to Installation
EBW Transport Systems, 2814 McCracken Ave, Muskegon MI 49441 - Sales Desk 1-800-207-9579, Sales Fax 1-800-475-4329
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
209
Section A
Petroleum Trailer Parts
OCS Guide to Installation
Diagrams
Three Wire Diagrams / with Retain Probes
EBW Transport Systems, 2814 McCracken Ave, Muskegon MI 49441 - Sales Desk 1-800-207-9579, Sales Fax 1-800-475-4329
210
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
Section A
Petroleum Trailer Parts
Diagrams
Wiring Schematic For Thermistor System
WHITE-GROUND AND SENSOR RETURN
PLUG TO SOCKET
LOCKING PIN
WHITE-AUXILIARY GROUND (OPTIONAL)
8
25
10
11
3
SOCKET TO PLUG
LOCKING J- SLOT
10
3
4
9
7
5
BLACK
VIOLET-DATA PIN (OPTIONAL)
11
4
5
6
5
THERMISTOR RECEPTACLE
(SOCKET)
THERMISTOR PLUG
4
YELLOW
3
RED
2
GREEN
1
BROWN
COMPARTMENT
NUMBER
EBW Transport Systems OCS Control Manual
6
BLUE
8
9
7
6
Wiring Schematic For Optical System
BLACK-GROUND AND SENSOR RETURN
PLUG TO SOCKET
LOCKING PIN
WHITE-AUXILIARY GROUND (OPTIONAL)
27
8
8
6
SOCKET TO PLUG
LOCKING J- SLOT
10
11
4
5
OPTIC PLUG
9
10
VIOLET-DATA PIN (OPTIONAL)
11
4
5
RED-SENSOR POWER (+)
6
ORANGE-RETURN PULSE FROM SENSOR
GREEN-DIAGNOSTIC (OPTIONAL)
OPTIC RECEPTACLE
(SOCKET)
YELLOW-PULSE TO SENSOR
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
EBW Transport Systems OCS Control Manual
9
211
IMPORTANT
Please read before installing
Section A
Petroleum Trailer Parts
Diagrams
1. The EBW 908-PF is a S.A.E. J-560 pattern
socket that conforms to API 1004 Standards.
3. When mounting socket housing using the holes
located inside of housing, a sealant should be used
around the mounting bolts to prevent moisture from
entering.
2. The wiring shown conforms to RP 1004
standards for controlling single stage "float switch"
type loading rack overfill control monitors. The user
should be aware that other wiring patterns do exist
that may prevent loading at these facilities,
therefore please consult your loading facility to
verify compliance with RP 1004.
Float Socket
4. The 6-32" screw located on outside of housing
should be in "top" hole when mounted to allow
drainage of condensation out the bottom hole.
Normally Closed
Float Switch
VEHICLE GND.
1 WHT
6
2 BLK
BRN
BLU 7
3 YEL
RED
VEHICLE
GND.
GRN
5
4
REAR VIEW OF SOCKET
Sales Desk (800) 475-3291 • Sales Fax (800) 475-4329 • Phone (231) 755-1671
®
2814 McCracken Avenue, Muskegon, MI 49441 • Fax (231) 755-7201 • http://www.ebw.com
©2000 EBW Inc. Form No 1107 4/00
VIP Chip
212
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
Phone: 800.828.6555 Fax: 864.583.1550
www.littlejohninc.com
Section A
Petroleum Trailer Parts
Diagrams
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
213
Section A
Petroleum Trailer Parts
Diagrams
214
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
Phone: 800.828.6555 Fax: 864.583.1550
www.littlejohninc.com
ROM II
H5517PA4.WPG
Section A
Petroleum Trailer Parts
Diagrams
10 WIRING INSTRUCTIONS - SOCKETS
Locate and mount the socket housings, using the bolt holes provided on the enclosure, in the vicinity of the
bottom loading adapters. Take into account the plug and cable that will be coming from the rack
monitoring equipment so that it does not interfere with the bottom loading adapters when connected.
Conduit openings are provided at the OBM so that each type of socket used may have its own conduit
connection only if the auxiliary inputs are not used. If the auxiliary inputs are used, use the convention
shown in Figure 2. It combines the Thermistor and Float outputs into one cable exit. This convention is
not required but will help in troubleshooting and tracing the system output if a problem should occur.
Cross reference the CIVACON part number of the socket to its proper wiring diagram and connect
accordingly (refer to Figures 6, 7, and 8 ). Please use the CIVACON Instruction Sheet H50200PA, which is
packaged with each socket, for additional reference information on the sockets.
Strain reliefs are recommended for all cable entry locations. Note that pipe plugs are required to be
installed in all of the openings which are not used for cable entry. A thread sealant is also recommended
to be used with each strain relief or pipe plug.
SuitableFIGURE
for connection
to the
Intrinsically
Safe outputs
CIVACON
5 - POWER
AND
INTRINSICALLY
SAFEfrom
WIRING
Rack Monitors, Models 8100
Series, DIAGRAM
8300 Series, 8400 Series.
CONTROL
Additional Notes:
CIVACON OPTIC SOCKETS
1Electrical Apparatus connected to the Onboard Monitors should not use or generate more than
250 Volts. Match your socket model number with the model numbers below.
2Installation
be inwires
accordance
NEC ANSI/NFPA
and ANSI/ISA
RP12.6
. In Canada,
Connectshould
the shown
below to with
the OPTIC
section of the70terminal
strip on the
monitor.
the system
must
be
installed
in
accordance
with
the
Canadian
Electrical
Code.
CAUTION: The OPTIC RED and
ORANGE
wires are NOT the same wires as the
o
o
C (140 F) . wires.
3Maximum ambient temperature is 60
THERMISTOR
4Maximum cable capacitance of 10.1 uF and cable inductance of 4.7 mH must not be exceeded.
(FMRC Only
Parameters)
MODEL
No.'s 4100, 4200, & 4201
MODEL No. 4300
5Model 3202 Intrinsically Safe Field Wiring parameters (FMRC Only) for TB3 Terminals
BRN/BRN/BLK, ORN/RED/BLK, and RED/ORN/YEL/BLK are :
Vmax. = 30 V. Vmax. ≥ Voc or Vt;
Ci = 0 uF.
Ca ≥ Ci + Ccable;
Imax. = 250 mA.
Imax. ≥ Isc or It;
Li = 0 mH.
La ≥ Li + Lcable.
6Maximum entity parameters (FMRC Only) for terminals TB5-1, 3, 5 (AUX INPUTS) are:
Vt = 12.8 V.
Ca = 8 uF.
Also see Note 5 parameters.
It = 8 mA.
La = 1 H.
Also see Note 5 parameters.
7TB4A, TB4B, & TB5-1, 3, 5 inputs are for simple switch mechanisms with NO inductance or
capacitance. They provide Intrinsically Safe circuits for passive switches or jumpers with NO
energy storing or discharging capability.
8CIVACON devices connected to TB2 are sensor Models 1050, 1020, 1000, 1001, and
replacement 1350; plus special length versions of the same models with an "S" suffix.
9Auxiliary Output terminal (Aux Out of TB5-6) can be connected to Auxiliary Input of secondary
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550
OBM module. Do not cross connect.
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
- Phone:
800.621.7131
- Fax:
708.442.9229
10 CIVACON devices connected to TB3 are Intrinsically Safe Chicago,
outputsIL from
rack
monitor
Models
8100
FIGURE 6 - OPTIC
www.littlejohninc.com
series, 8300 series, and 8400 series. The connections are less than 50 feet.
VIEWED FROM WIRE CONNECTION SIDE
11 Do not modify this control diagram without notifying all approval agencies.
12 The following diagrams are part of Figure 5. Diagram A1, A2, A3, A4, A5, & A6.
215
Section A
Petroleum Trailer Parts
Diagrams
DIAGRAM A5 - 5 COMPARTMENT
Phone: 800.828.6555 Fax: 864.583.1550
CIVACON
www.littlejohninc.com
© Copyright 1997
216
15
Spartanburg, SC - Phone: 800.828.6555 - Fax: 864.583.1550 598
Cincinnati, OH - Phone: 866.879.9773 - Fax: 513.860.1355
Chicago, IL - Phone: 800.621.7131 - Fax: 708.442.9229
www.littlejohninc.com
Ph
H51517PA
MAY 1997