50 Hz
Transcription
50 Hz
www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru Technical Details 1.1 Design Figure 1: Operating point of the ventilator Elektror low pressure blowers of the ND range are radial ventilators with impellers made from galvanized sheet steel, the blades of which are curved into direction of rotation. They are directly driven by asynchronous squirrel cage motors of the company´s own make, especially adapted to the blower requirements and amply dimensioned. Characteristic ventilator curve ▼ The attractively shaped, stream-line aluminium-cast housings as well as the dynamically balanced impellers ensure vibrationfree operation at low noise levels. pt pst ▼ Operating point Pressure difference R The solid design of the Elektror low pressure blowers is basic for long-life operation and low operating cost. All drive motors are manufactured to enclosure IP 54 and in accordance with VDE 0530 (IEC 34-1). As a standard the motors are laid out for a voltage of 230/400 V or 400 V g at 50 Hz mains frequency three-phase AC and for 230 V 50 Hz single-phase AC in accordance with IEC 38. On demand the motors for 60 Hz. mains frequency can also be supplied to IEC 38. Characteristic system curve . Volumetric flow rate V R 1.3 Noise characteristics 1.2 Performance The noise caused by a ventilator ensues from flow processes and vortices inside the impeller and the housing and is determined by Ventilators are flow-generating appliances for conveying air and other gases. As for the radial blowers, the conveyed medium is drawn in axially, accelerated radially by the rotation of the impeller and expelled tangentially. The resistance to the discharged air (by duct work, pipes, filters and other parts of the installed system) has to be compensated by the generated excess pressure of the ventilator. The ability of the ventilator to generate pressure diminishes with increasing flow volume (volumetric flow rate). This operating behaviour depends on the characteristic curves of pressure difference and volumetric flow rate (specific ventilator curves). a) the basic design of the ventilator (axial, radial, construction principle of impeller). b) the size of the ventilator in relation to the requested pressure differentials and flow volumes. c) the operating point of the ventilator, i.e. in which range of the characteristic curve the ventilator will be operated. d) the rotational speed which can be reduced by the variable speed control for the Elektror low pressure blowers. The resistance of air-conditioning systems (system resistance) varies (in most cases) by the square of the changing volumetric flow rate, i.e.: If the flow volume is to be doubled, four times the system’s resistance has to be compensated. The resulting characteristic curves are termed resistance parabolas or characteristic system curves. Noise emissions are not constant over the whole performance range. Blower housing and impeller are especially designed for the required flow conditions, whereby the noise generation depends mainly on the required flow volume and pressure difference as well as on the correct selection of the ventilator. The operating point of the ventilator is determined by the intersection of the two characteristic curves. For evaluation of the noise respectively of the sound pressure level the measuring unit dB(A) is used. The letter “A” in the measuring unit refers to the standardized frequency evaluation which takes into account the highly frequency-dependent and subjective perception of noise levels: High frequencies ar perceived as more unpleasant than lower ones. As far as the system resistance cannot exactly be calculated mathematically, recourse should be taken to experiment or empiric values. With increasing system resistance the flow volume decreases and the power consumption drops. The maximum volumetric flow rate of the ventilator is determined by the intersection of the characteristic curves gPt and Pd2 (see figure 1). If a number of sound sources of equal volume are evaluated together, the sound pressure level will increase for instance by 2 dB for two appliances, by 5 dB for three, 6 dB for four, and 7 dB for five. A change by 10 dB eventually means double or half the noise level perception. With increasing distance from a sound source noise emissions grow weaker; doubling the distance may result in a noise level reduction of up to 5 dB. 4 www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru 1.4 Performance curves Influence of density The indicated performance curves of the total pressure head gPt and of the . static pressure gPst as function of the volumetric flow rate V have been ascertained by measuring tests and are partially above the values specified in the technical tables. The measurements were performed without protective wire mesh guard on the intake side. Total pressure difference, dynamic pressure, static pressure and power consumption of the blower change in proportion to the density of the conveyed medium and are to be considered when selecting a blower (figure 3). All measurements were taken on a pipe test bed to DIN 24 163 with throttling on the discharge side, and based on an air density of 1,2 kg/m3. ρ2 = ρ1 273 + q1 273 + q2 Alterations in density due to influence of temperature are calculated as follows: The sound pressure levels LA have been ascertained on the intake side at a distance of 1 m from the inlet with the blowers connected on the discharge side to the pipe test bed. q = temperature of conveyed medium [°C] ρ = air density [kg/m3] Figure 3: Influence of density of conveyed medium ρ = 1,4 kg/m3 ρ = 1,2 kg/m3 catalogue data 1.5 Blower selection Applicable pressure difference If the required pressure difference and the desired air volume have been established either by testing or by calculation, it should be verified how much of the total pressure rise of the blower can be used as static pressure difference. pt Total pressure rise g pt R Increasing the cross-section of the discharge duct work by gradual enlargement (difusor) will delay the volume flow, and the dynamic pressure will be converted to static pressure. The recovered pressure may be included to overcome the system resistance, or allow for the use of a smaller blower at the same volumetric flow rate (see performance curve 2, figure2). The efficiency of difusors depends on the opening angle. Pressure gains by difusors on the intake side are unimportant and may be neglected. ▼ Required power of blower P R ▼ If the duct work connected to the discharge side has the same coss-section as the discharge port of the blower, or if the blower discharges freely, the dynamic pressure part Pd2 must be considered a loss. The remaining part of the total pressure rise is then available as applicable static pressure difference gPst. pt P P . Volumetric flow rate V R Figure 2: Pressure recovery Ventilator performance curve 1 ▼ Ventilator performance curve 2 ▼ Total pressure rise g pt R pt Operating point 1 without difusor pt Fields of application Elektror low pressure blowers offer a wide field of application facilities: Pressure recovery by difusor ● Conveying of large air volumes at smaller and medium system resistance Operating point 2 with difusor ● Exhausting gases and vapours ● Cooling of apparatus and machinery parts ● Ventilation of rooms ● Chimney draft boosting ● Air supply to gas-, oil- and coal-fired systems . Volumetric flow rate V R ● Drying parts of various structure ● Ventilation of electric machines 5 www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 1.6 Standard and special designs elektror-mail@ya.ru Model range RS 2-step version for three phase and single phase a.c. with installed temperature controller as motor protection for which the speed-control can be effected via step switch. Standard range Application is useful wherever unchanging operating conditions prevail or pressure relations vary slighty only and a constant flow volume is required. All units of the standard range correspond to the safety requirements of the Supervisory Board of the Chemical Industry and have been tested and certified. Speed controlled blowers of the range RVE and RS cannot be delivered with temperature barrier. Maximum temperature of the conveyed medium is 40° C. Model range FU All standard blowers can be speed-controlled via frequency converter. The motors are equipped with PTC thermistor sensors for trip device and with a reinforced barrier. Twin blowers Driven by one common motor and attached to both sides of it, two blowers are assembled into one single unit as a special construction design. The advantage of these blowers is the high flow volume with small dimensional layout. As the twin blowers possess two discharge connectors, the volumetric flow rates may be used together or separately for the respective applications. The technical data are identical with those of the standard blowers. Speed control form 0 to 50 Hz maximum. Compact blowers The design offers very compact dimensions by incorporating the motor into the blower housing respectively into the impeller at comparatively favourable characteristic curves. The motor needs no additional cooling as it is located in the air flow. To guarantee sufficient cooling of the motor the blower cannot be operated fully throttled – neither on the discharged side nor on the intake side. In case of high air pollution a filter must be fitted on the intake side to avoid contamination of motor and impeller. Speed controlled blowers They are to be used wherever for process-inherent reasons the change of volumetric flow is needed. Model range RVE Special blowers By means of a generalised phase control, which is housed in the terminal box of the motor in a space-saving way, any random operating point can be continuously adjusted within a range of 20 to 100 % within the characteristic field by means of the potentiometer supplied. A two-stage setting is possible as well. For special applications the standard blowers can be adapted to existing requirements by special equipment whereat also customermade solutions can be found. In case of speed reduction, energy is saved effectively in the partial load range, and the noise generation is reduced distinctly. Alternating current motors speed adjustable by voltage reduction from own production are used as drives especially adapted to the ventilator. The motors have been equipped with PTC thermistors so that a thermistor-type motor protection is ensured in combination with the generalised phase control. Thus, the user has a wide range of applications with ideal problem solution and the following advantages: ● Continuously adjustable from 20 to 100 % ● Absolutely free from maintenance ● Considerable reduction of the sound emission in case of speed reduction 6 www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru Conveyed medium and ambient temperatures Voltage and frequency The permitted ambient temperature (cooling air temperature) of the drive motors is -30 °C to + 40 °C. As a standard the motors are made to thermal class B in accordance with VDE 0530 (IEC 34-1), the speed-controlled version to thermal class F. The motors of the standard version are made for a voltage of 230/400 V ( g / V ) or 400 V (g) three phase a.c. at 50 Hz mains frequency and for 230 V single phase a.c. in accordance with IEC 38. On demand the motors for 60 Hz mains frequency can also be supplied to IEC 38. An increase in the permitted ambient temperature above 40 °C is possible by using suitable insulation materials. This should be discussed with the manufacturer, however. Special voltage and special frequency as well as motors for voltage change-over or multi-range voltage can be supplied on demand. The permitted temperature of the conveyed medium for the standard range is from -30 °C to +80 °C. Permitted maximum voltage for three phase a.c. is 690 V and 277 V for single phase a.c. The fitting of a temperature barrier to the standard units between blower and motor allow for conveyed medium temperatures of up to 80 °C. An alteration of the mains frequency leads to a change of the motor speed (r.p.m.) and of the impeller whereby the total pressure rise, the flow volume and the power consumption change as follows: Sealing Higher enclosure to IP 55 and IP 65 as well as tropical and moisture-proof insulation are possible for all motors. n2 If the blowers have to be gas- and air-tight to a certain extent, a rotary PTFE shaft seal can be fitted into the shaft bore. Further sealing options of the blower parts are flat gaskets or elestic sealants. By choice of material (cast and sheet aluminium) the standard blowers are already nearly corrosion-resistant. For special applications, the blowers may be painted or coated with plastic resin. the impellers can be manufactured from alloy 1.4301. The standard blowers are equipped with two-pole motors. Change-pole motors 4/2 or 4-pole motors, can be supplied on demand. An alteration of the number of revolutions of the blower will change the total pressure rise, the flow volume and the power comsumption as follows: gp t 2 n2 P2 . V 12 n = gp t1 2 . n1 V2 = n1 . V1 n2 = P1 n1 = flow volume 2 12 g p t = total pressure rise n = number of revolutions P = power consumption f = frequency 12 f2 f1 . V2 . f = V1 2 f1 P2 = P1 2 12 f2 f1 3 The characteristic curves and the power consumption of blowers with 60 Hz drive change as indicated in the technical data for each model. Blower speeds . n = V1 2 n1 f2 f1 g p t 2 = g pt1 Corrosion protection . V2 = n1 3 7 www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 1.7 Directions for operation and maintenance Elektror low pressure blowers are equipped with sealed grooved ball bearings which do not need relubrication. The grease filling is sufficient for their operational life. Inspection and eventual cleaning should be carried out at regular intervals with special attention to the safety instructions. Soiled and worn impellers cause an unbalance which may result in bearing failure. Safety of operation as well as the indicated performance data are no longer guaranteed. Conveying of solids is not permitted. If the conveyed medium contains solid particles or other pollutions, the have to be removed before entering the blower by a filter on the intake side. Permeability of the filter must be ensured. Conveying of explosive mixtures is not permitted. Blower with open discharge or intake ports have to be equipped with a contact safety device in accordance with DIN EN 294 as far as such a device has not already been fitted in the factory. The units have to be installed in weather-protected places and must not be exposed to strain by vibrations, shocks and percussions. Units above 3 kW must be started in ( g / V ) configuration. The instructions for installation and operation supplied with the blower unit have strictly to be adhered to. 1.8 Details for ordering Blower type Volumetric flow rate Required total pressure or static pressure difference Voltage, frequency, current (3- or 1-phase a. c.) Ambient and conveyed medium temperature Density of conveyed medium Housing position Accessories/special requirements 1.9 Remarks Dimensions, technical data and descriptions are approximate only. Subject to modifications and error. 8 elektror-mail@ya.ru www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru Low Pressure Blowers 2. Housing positions Housing positions A, B, C and E, F, G, as well as the version without foot base are available for all types of low pressure blowers. Other positions are deliverable on demand. The intended position should also be stated for the version without foot base. The housing positions is determined on facing the intake side: Positions Ar – Dr = clockwise rotation Positions El – Hl = counter-clockwise rotation The designations in brackets are according to VDMA 24 165 but they are determined on facing the drive side. Orders without indicated housing position will be supplied in standard version Ar. Ar (LG 270) Br (LG 0) El (RD 270) Fl (RD 0) Cr (LG 90) Dr (LG 180) GI (RD 90) HI (RD 180) Type code for low pressure blowers Blower 2 D/E 0 60 RV or RS RV = speed variable, infinitely or by 5 steps single phase motors by 7 steps RS = speed variable, by 2 steps Frame size Low pressure blower D = with three phase a.c. motor E = with single phase a.c. motor Twin blower-type Type code for compact blowers Blower D/E K 10 Frame size Compact blower D= with three phase a. c. motor E= with single phase a. c. motor 9 www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru Low Pressure Blowers 3. Low Pressure Blowers Standard blowers Standard blowers page 11 to 15 Pa Pa 600 2000 page 16 to 21 1800 500 1600 1400 400 D 08 Static pressure rise g pst R Static pressure rise g pst R 1200 D 052 300 D 05 200 D 04 D 03 100 E 02SP 5 10 300 600 . Volumetric flow rate V R 15 900 Twin blowers D 066 1000 800 D 092 D 060 200 m3/min m3/h 10 20 30 40 50 60 70 80 90 100 1200 2400 3600 4800 6000 . Volumetric flow rate V R Compact blowers page 22 to 28 1600 1200 page 34 to36 1000 2D 08 1200 DK 2/2 800 1000 2D 07 2D 060 Static pressure rise g pst R Static pressure rise g pst R m3/min m3/h DK 3/2 1400 400 D 082 400 Pa 600 D 072 D 064 600 Pa 1800 800 D 09 D 07 2D 064 2D 052 2D 05 200 2D 04 10 20 30 40 50 60 70 80 90 100 1200 2400 3600 4800 6000 . Volumetric flow rate V R m3/min m3/h DK 1/2 600 400 200 5 20 1200 . Volumetric flow rate V R 10 10 600 15 25 30 1800 35 m3/min m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru E02 SP Standard blowers 149 112 1 34 80 82 46 54 70 47,5 90 137 105 M4 7 5 46 54 70 85 154 Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg E02 SP 1,75 210 230 50 0,51 2630 0,05 – 2,3 E02 SP 1,9 310 230 60 0,38 2840 0,05 – 2,3 60 LA 250 55 50 dB (A) 200 pt ▼ 150 LA 60 55 350 300 250 200 pt 150 ▼ pst Pressure rise R 100 ▼ Pressure rise R Pa ▼ Pa Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz dB (A) Type 50 0,5 30 1 60 . Volumetric flow rate V R 1,5 90 2 120 m3/min m3/h 50 0,5 30 1 60 . Volumetric flow rate V R 11 pst 100 1,5 90 2 120 m3/min m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru D 03, E 03 Standard blowers 128 120 M5 67 172 95 5 95 181 Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg D 03 3,2 330 230/400 50 0,23/0,13 2820 0,03 – 3,7 D 03 3,8 480 277/480 60 0,28/0,16 3400 0,05 – 3,7 E 03 3,2 330 230 50 0,40 2880 0,03 3/450 3,9 E 03 3,8 480 230 60 0,50 3350 0,05 3/450 3,9 60 50 350 pt ▼ dB (A) 300 250 ▼ 200 Pa LA 500 pt 400 pst 300 pst 150 200 Pressure rise R Pressure rise R 70 60 ▼ LA ▼ 70 Pa Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz dB (A) Type 100 50 0,5 30 1 60 1,5 90 2 120 . Volumetric flow rate V R 2,5 150 3 180 3,5 210 m3/min m3/h 100 0,5 30 2 2,5 120 150 . Volumetric flow rate V R 12 1 60 1,5 90 3 3,5 180 210 4 240 m3/min m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru D 04, E 04 Standard blowers 150 140 M5 83 213 106 6 110 217 Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg D 04 5,0 350 230/400 50 0,43/0,25 2850 0,07 – 4,5 D 04 6,0 500 277/480 60 0,48/0,28 3400 0,12 – 4,5 E 04 5,0 350 230 50 0,8 2850 0,07 3/450 4,7 E 04 6,0 500 230 60 0,75 3400 0,12 3/450 4,7 500 70 65 pt ▼ dB (A) 400 60 ▼ 300 pst Pa LA 75 70 700 600 500 pt 65 dB (A) LA ▼ Pa pst 400 Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz ▼ Type 300 Pressure rise R Pressure rise R 200 100 1 60 2 120 3 180 . Volumetric flow rate V R 4 240 5 300 m3/min m3/h 200 100 1 60 3 4 180 240 . Volumetric flow rate V R 13 2 120 5 300 6 360 m3/min m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru D 05, E 05 Standard blowers 160 147 85 116 241 M5 8 for speed-controlled execution ( ) 130 251 Design with foot base on demand Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg D 05 10,0 430 230/400 50 0,57/0,33 2550 0,13 – 5,0 D 05 11,0 620 277/480 60 0,78/0,45 3000 0,22 – 5,0 E 05 10,0 430 230 50 1,1 2550 0,14 3/450 5,2 E 05 9,5 620 230 60 0,9 3300 0,14 3/450 5,2 600 70 500 pt ▼ 400 dB (A) 65 Pa 800 75 70 65 pt 700 pst 600 500 pst ▼ 400 Pressure rise R 300 Pressure rise R LA ▼ LA 75 ▼ Pa Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz dB (A) Type 200 100 2 120 4 240 6 360 . Volumetric flow rate V R 8 480 10 600 m3/min m3/h 300 200 100 2 120 6 360 . Volumetric flow rate V R 14 4 240 8 480 10 600 m3/min m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru D 052, E 052 Standard blowers 180 171 M5 8 91,5 254 11 8 108 232 Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg D 052 15 530 230/400 50 1,7/0,95 2710 0,28 – 6,4 D 052 17,5 760 277/480 60 1,56/0,9 3180 0,45 – 6,4 E 052 14 530 230 50 1,9 2560 0,24 10/450 6,4 E 052 17,5 760 230 60 2,7 3100 0,43 8/450 6,4 70 800 60 pt dB (A) 700 ▼ 600 500 ▼ LA 1000 900 800 700 pst 500 300 400 200 100 4 240 6 360 8 10 480 600 . Volumetric flow rate V R 12 720 pt 60 pst 600 400 2 120 80 70 Pressure rise R Pressure rise R 80 dB (A) LA Pa ▼ Pa Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz ▼ Type 14 840 16 960 m3/min m3/h 300 200 100 2 120 4 240 6 8 360 480 10 600 . Volumetric flow rate V R 15 12 14 720 840 16 18 m3/min 960 1080 m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru D 060, E 060 Standard blowers 285 188 176 185 107 312 127 10 95 120 13 10 M5 140 Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg D 060 22 730 230/400 50 2,4/1,4 2780 0,53 – 9,6 D 060 27 1040 277/480 60 3,45/2,0 3350 0,98 – 10,6 E 060 22 730 230 50 3,8 2790 0,53 16/450 11,1 E 060 26 1040 230 60 6,0 3250 0,88 20/450 11,1 80 75 800 70 pt ▼ 700 600 pst dB (A) 900 LA 80 1200 75 1000 800 ▼ 500 pt pst 600 Pressure rise R 400 Pressure rise R 85 dB (A) LA Pa ▼ Pa Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz ▼ Type 300 200 100 5 300 10 600 . Volumetric flow rate V R 15 900 20 1200 25 m3/min 1500 m3/h 400 200 5 300 15 900 . Volumetric flow rate V R 16 10 600 20 1200 25 30 m3/min 1500 1800 m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru D 064, E 064 Standard blowers 311 210 198 M5 131 210 355 147 10 120 145 10 140 Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg D 064 27 1050 230/400 50 3,8/2,2 2830 0,90 – 14,9 D 064 32 1550 277/480 60 4,7/2,7 3310 1,35 – 14,9 E 064 28 1000 230 50 6,0 2840 0,90 30/450 16,9 E 064 33 1500 230 60 9,0 3350 1,4 30/450 16,9 1200 ▼ 800 pt 75 dB (A) 1000 80 pst Pa LA 1600 pt 85 80 75 1400 1200 dB (A) LA 85 ▼ Pa pst 1000 Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz ▼ Type ▼ 800 600 Pressure rise R Pressure rise R 600 400 200 5 300 10 600 15 20 900 1200 . Volumetric flow rate V R 25 1500 30 m3/min 1800 m3/h 400 200 5 300 10 600 15 900 20 1200 . Volumetric flow rate V R 17 25 1500 30 1800 35 m3/min 2100 m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru D 066, E 066 Standard blowers Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg D 066 38 1200 230/400 50 5,9/3,4 2820 1,4 – 18,1 D 066 38 1300 277/480 60 6,1/3,5 3420 1,6 – 18,1 E 066 36 1200 230 50 8,0 2740 1,3 30/450 18,1 E 066 37 1380 230 60 9,5 3350 1,5 30/450 18,1 LA 1400 ▼ pt dB (A) 1200 85 80 75 1000 Pa 85 80 75 1400 1200 pt 1000 800 800 pst ▼ Pressure rise R 600 400 200 5 300 10 600 15 900 20 25 30 35 1200 1500 1800 2100 . Volumetric flow rate V R m3/min m3/h ▼ 600 Pressure rise R LA dB (A) Pa Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz ▼ Type pst 400 200 5 300 20 25 30 35 1200 1500 1800 2100 . Volumetric flow rate V R 18 10 600 15 900 m3/min m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru D 07, D 072 Standard blowers 438 (463) 348 (373) D 072 ( ) Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg D 072 41 1200 230/400 50 7,5/4,3 2830 1,8 – 22 D 072 41 1600 277/480 60 7,6/4,4 3440 2,4 – 22 D 072 52 1200 230/400 50 10,0/5,8 2860 2,6 – 24 D 072 52 1600 277/480 60 10,2/5,9 3430 3,4 – 24 LA 07 ▼ D 1200 pt 2200 2 1400 ▼ 1000 Pressure rise R Pressure rise R 1200 pst 200 30 1800 . Volumetric flow rate V R 40 2400 50 3000 pt 07 1600 400 20 1200 D 07 1800 600 10 600 80 2000 2 07 800 90 85 D D 1000 dB (A) 1400 LA ▼ 1600 85 80 75 Pa dB (A) Pa 60 m3/min m3/h 600 400 200 30 1800 . Volumetric flow rate V R 20 1200 40 2400 50 3000 Blower not to be operated with free discharge. 19 pst 800 10 600 D 07 not to be operated with free discharge. Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz ▼ Type 60 m3/min m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru D 08, D 082 Standard blowers D 082 ( ) Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg D 082 50 1700 230/400 50 10,0/5,8 2860 2,6 – 29 D 082 50 2300 277/480 60 9,7/5,6 3450 3,2 – 29 D 082 62 1700 230/400 50 11,8/6,8 2830 3,1 – 31 D 082 58 2300 277/480 60 11,8/6,8 3450 3,8 – 31 85 ▼ 2000 1800 1400 80 75 dB (A) D 082 D 08 1600 pt pst ▼ 1200 Pa 2800 LA 2400 pt 85 D 082 D 08 2000 1600 1000 90 pst dB (A) LA ▼ Pa Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz ▼ Type 1200 Pressure rise R Pressure rise R 800 600 400 200 10 600 20 1200 30 40 1800 2400 . Volumetric flow rate V R 50 3000 60 3600 70 m3/min m3/h 800 400 10 600 30 40 1800 2400 . Volumetric flow rate V R Blower not to be operated with free discharge. 20 1200 50 3000 Blower not to be operated with free discharge. 20 60 3600 m3/min m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru D 09, D 092 Standard blowers Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg D 092 80 1900 400 g 50 11,8 2880 5,5 – 66 D 092 80 2700 480 g 60 10,5 3500 6,0 – 66 D 092 95 1900 400 g 50 15,0 2900 7,0 – 71 D 092 91 2700 480 g 60 12,0 3530 7,0 – 71 LA 95 90 85 ▼ 2000 D pt 09 2 1600 dB (A) D 09 Pa LA 100 95 90 2800 D 09 2400 pt D 092 2000 dB (A) Pa Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz ▼ Type 1600 1200 Pressure rise R 1200 400 10 20 30 40 50 60 70 80 90 100 1200 2400 3600 4800 6000 . Volumetric flow rate V R m3/min m3/h ▼ ▼ Pressure rise R pst 800 800 pst 400 10 20 30 40 50 60 70 80 90 100 1200 2400 3600 4800 6000 . Volumetric flow rate V R D 09 not to be operated with free discharge. D 09 not to be operated with free discharge. 21 m3/min m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru 2D 04 Twin blowers 150 140 M5 118 83 213 106 6 110 217 Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg 2D 04 10 350 230/400 50 0,61/0,35 2830 0,14 – 6,7 2D 04 12 500 277/480 60 0,87/0,5 3320 0,24 – 6,7 500 65 pt 60 ▼ dB (A) 400 300 Pa LA 70 65 600 pt 500 400 60 dB (A) LA 70 ▼ Pa pst Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz ▼ Type pst ▼ 300 Pressure rise R Pressure rise R 200 100 2 120 4 240 6 360 . Volumetric flow rate V R 8 480 10 600 m3/min m3/h 200 100 2 120 6 360 . Volumetric flow rate V R 22 4 240 8 480 10 600 12 720 m3/min m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru 2D 05 Twin blowers 160 147 M5 85 241 116 8 130 250,5 Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg 2D 05 21 430 230/400 50 1,91/1,1 2770 0,35 – 8,4 2D 05 24 620 277/480 60 2,15/1,25 3200 0,55 – 8,4 LA 75 70 65 ▼ 500 pt 400 dB (A) 600 Pa LA 800 700 500 ▼ ▼ 200 100 5 300 10 600 . Volumetric flow rate V R 15 900 20 1200 pst 400 Pressure rise R Pressure rise R 300 pt 600 pst 80 75 70 dB (A) Pa Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz ▼ Type m3/min m3/h 300 200 100 5 300 10 600 15 900 . Volumetric flow rate V R 23 20 1200 25 1500 m3/min m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru 2D 052 Twin blowers 180 171 M5 91,5 254 118 8 108 232 Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg 2D 052 30 530 230/400 50 2,7/1,5 2850 0,56 – 11,0 2D 052 30 760 277/480 60 2,7/1,5 3420 0,80 – 11,0 75 70 700 65 ▼ 600 500 pt dB (A) 800 Pa LA 1000 75 900 800 700 pst 600 pst pt 70 500 ▼ 400 400 300 Pressure rise R Pressure rise R 80 dB (A) LA ▼ Pa Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz ▼ Type 200 100 5 300 10 600 15 20 900 1200 . Volumetric flow rate V R 25 1500 30 m3/min 1800 m3/h 300 200 100 5 300 10 600 15 900 20 1200 . Volumetric flow rate V R 25 1500 30 1800 Blower not to be operated with free discharge. 24 35 m3/min 2100 m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru 2D 060 Twin blowers 285 188 176 168 107 295 127 M5 10 140 Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg 2D 060 50 730 230/400 50 6,4/3,7 2900 1,25 – 18,8 2D 060 54 1040 277/480 60 6,1/3,5 3470 1,75 – 18,8 80 1000 75 pt ▼ dB (A) 800 70 600 Pa LA 1400 85 80 pt 75 1200 1000 ▼ LA ▼ Pa pst 800 pst Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz dB (A) Type ▼ 600 Pressure rise R Pressure rise R 400 200 10 600 20 1200 30 1800 . Volumetric flow rate V R 40 2400 50 3000 m3/min m3/h 400 200 10 600 20 1200 30 1800 . Volumetric flow rate V R 40 2400 50 3000 Blower not to be operated with free discharge. 25 m3/min m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru 2D 064 Twin blowers 210 198 342 197 131 147 M5 10 140 312 Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg 2D 064 60 1000 230/400 50 6,3/3,6 2870 1,8 – 25 2D 064 57 1440 277/480 60 6,4/3,7 3460 2,2 – 25 85 80 75 ▼ pt 70 dB (A) 1200 1000 800 Pa LA 1600 1400 pt 1200 1000 85 80 75 dB (A) LA ▼ Pa pst Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz ▼ Type pst ▼ 800 600 Pressure rise R Pressure rise R 600 400 200 10 600 20 1200 30 40 1800 2400 . Volumetric flow rate V R 50 3000 60 m3/min 3600 m3/h 400 200 10 600 20 1200 30 40 1800 2400 . Volumetric flow rate V R 50 3000 Blower not to be operated with free discharge. 26 60 3600 m3/min m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru 2D 07 Twin blowers Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg 2D 07 94 1200 400 g 50 9,5 2930 4,5 – 50 2D 07 77 1600 480 g 60 8,7 3540 4,8 – 50 85 80 75 1600 pt ▼ 1200 1000 ▼ LA 2000 1600 pst 1200 pst 1000 600 800 400 200 20 30 40 50 60 70 80 90 1200 2400 3600 4800 . Volumetric flow rate V R 85 80 1400 800 10 pt 1800 Pressure rise R Pressure rise R dB (A) 1400 Pa m3/min m3/h 600 400 200 10 40 50 2400 . Volumetric flow rate V R Blower not to be operated with free discharge. 20 1200 30 60 3600 70 Blower not to be operated with free discharge. 27 dB (A) LA ▼ Pa Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz ▼ Type 80 4800 m3/min m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru 2D 08 18 8 Twin blowers 256 27 2 Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg 2D 08 95 1700 400 g 50 10,0 2910 5,0 – 52 2D 08 95 2300 480 g 60 10,0 3520 5,8 – 52 85 80 ▼ 2000 pt dB (A) 1800 1600 ▼ pst LA 2600 90 85 2400 pt 2200 2000 pst 1800 1600 1200 1400 1000 1200 1000 800 Pressure rise R Pressure rise R 1400 Pa dB (A) LA ▼ Pa Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz ▼ Type 600 400 200 10 20 30 40 50 60 70 80 90 100 1200 2400 3600 4800 6000 . Volumetric flow rate V R m3/min m3/h 800 600 400 200 10 20 30 40 50 60 70 80 90 100 1200 2400 3600 4800 6000 . Volumetric flow rate V R Blower not to be operated with free discharge. Blower not to be operated with free discharge. 28 m3/min m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru DK 1/2, EK 1/2 Compact blowers Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg DK 1/2 12,5 11,5 750 1000 380–520 V 50 60 0,6 1650 2100 0,34 0,42 – 7,0 EK 1/2 11 750 230 50 1,53 2100 0,35 5/450 7,0 EK 1/2 10 1000 220 60 2,1 2600 0,45 5/450 7,0 LA 700 75 70 pt dB (A) 600 ▼ 500 Pa 1100 80 1000 75 LA 900 70 800 ▼ Pa 800 700 pt 600 400 Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz dB (A) Type 500 Pressure rise R 400 200 ▼ Pressure rise R ▼ 300 100 2 120 4 240 6 360 8 480 . Volumetric flow rate V R 10 600 12 720 pst 14 840 m3/min m3/h pst 300 200 100 2 120 4 240 6 360 8 480 . Volumetric flow rate V R 10 600 12 720 Blower not to be operated with free discharge. 34 14 840 m3/min m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru DK 2/2 Compact blowers Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg DK 2/2 30 1000 230/400 50 3,0/1,7 1740 0,5 – 16,0 DK 2/2 32 1400 277/480 60 3,7/2,1 2280 0,9 – 16,0 LA 1000 80 800 dB (A) 75 pt Pa 85 80 75 1400 1200 pt 1000 ▼ 600 800 600 200 5 300 10 600 15 20 900 1200 . Volumetric flow rate V R 25 1500 Pressure rise R 400 ▼ Pressure rise R LA dB (A) 85 ▼ Pa Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz pst 30 1800 m3/min m3/h ▼ Type 400 200 5 300 15 20 900 1200 . Volumetric flow rate V R 10 600 25 1500 Blower not to be operated with free discharge. 35 pst 30 1800 m3/min m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru DK 3/2 Compact blowers Dimensions in mm – subject to modifications Volumetricflow rate Total pressure difference Voltage Frequency Current consumption Number of revolutions Motor rating Capacitor Weight m3/min Pa V Hz A min–1 kW µF/V kg DK 3/2 36 1300 230/400 50 5,0/2,9 2000 0,9 – 16,5 DK 3/2 34 1500 277/480 60 4,9/2,8 2780 1,2 – 16,5 1600 85 80 75 1400 ▼ pt LA 1600 1400 1000 600 600 Pressure rise R 800 400 200 5 300 10 600 15 900 pst 20 25 30 35 1200 1500 1800 2100 . Volumetric flow rate V R pt pst 1200 800 ▼ Pressure rise R 1000 dB (A) 1200 Pa m3/min m3/h 400 200 5 300 20 25 30 35 1200 1500 1800 2100 . Volumetric flow rate V R 10 600 15 900 Blower not to be operated with free discharge. 36 85 80 dB (A) LA ▼ Pa Sound pressure level LA R 60 Hz Sound pressure level LA R 50 Hz ▼ Type m3/min m3/h www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru Accessories Throttle valve for fitting on the blower discharge side Blower type E 02 SP D 03, E 03 D 04, E 04 2D 04 D 05, E 05 2D 05 D 052, E 052 2D 052 D 060, E 060 2D 060 D 064, E 064 2D 064 D 066, E 066 D 07 D 072 2D 07 D 08 D 082 2D 08 D 09 D 092 Discharge connector for tube connection Intake connector Blower type E 02 SP D 03, E 03 D 04, E 04 2D 04 D 05, E 05 2D 05 D 052, E 052 2D 052 D 060, E 060 2D 060 D 064, E 064 2D 064 D 066, E 066 D 07 D 072 2D 07 D 08 D 082 2D 08 D 09 D 092 d e f h No. Code no. 70 72 70 72 7 7 54 56 54 56 20 20 BST 286 BST 287 0034 0035 76 76 7 64 64 20 BST 288 0095 112 112 9 96 96 20 BST 289 0036 130 130 7 105 115 20 BST 2553 0264 140 140 9 115 115 20 BST 2706 1350 150 130 9 130 110 20 BST 2097 0093 155 155 9 130 130 20 BST 2769 01129 190 210 11 160 180 20 BST 2098 0094 190 190 11 165 165 20 BST 2074 0106 220 220 11 196 196 20 BST 2264 0490 b d1 d2 d3 e f h1 h2 Part No. Code No. 70 72 70 72 7 7 46 52 54 60 54 56 54 56 70 70 5 5 10 997 10 998 0043 0044 80 80 7 60 70 64 64 70 6 10 999 0045 112 112 9 86 96 96 96 100 8 2499 0046 130 130 7 92 99 105 115 100 8 14 830 0273 140 140 9 110 120 115 115 100 10 15 304 1351 150 130 9 104 114 130 110 100 12 11 640 0123 155 155 9 125 135 130 130 100 12 15 934 01144 190 210 11 150 160 160 180 120 12 2497 0048 190 190 11 155 165 165 165 100 12 11 639 0124 220 220 11 170 180 196 196 140 15 12 357 0489 h1 h2 Part No. Code No. 100 6 13 728 0713 100 6 12 675 0714 100 6 12 674 0715 100 6 14 829 0254 120 6 12 673 0716 140 6 12 672 0717 d1 E 02 SP D 04, E 04 2D 04 D 05, E 05 2D 05 D 052, E 052 2D 052 D 060, E 060 2D 060 D 064, E 064 2D 064 D 066, E 066 D 07 D 072 2D 07 D 08 D 082 2D 08 D 09 D 092 b a Blower type D 03, E 03 a d2 d3 d4 d5 on demand 100 120 131 90,5 120 140 151 110,5 130 147 160 119,5 151 171 180 140 150 176 188 140 160 198 210 149,5 4u 5,8 4u 5,8 4u 5,8 4u 5,8 4u 5,8 4u 5,8 190 238 252 179 4u7 160 10 12 687 0718 220 256 272 208 4u7 160 10 12 662 0719 250 290 310 234 8u7 180 10 12 369 0488 Dimensions in mm – subject to modifications 37 www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru Accessories Fine filter intake side Layout and dimensions of Elektror fine filters are adapted to the maximum flow volume of the respective blowers and have a very small pressure loss therefore. The filter surface has been selected for an air resistance of 50 Pa at an air flow velocity of q,5 m/s. The insert filter tissue of synthetic fibres provides a high filtration efficiency of about 99 %. Dirty filters may be cleaned with compressed air or by washing with a light soap lye. All steel parts are zinc-galvanisied to provide high corrosion protection Caution Clogged and dirty filters reduce the blower performance significantly. Cleaning of the filters in regular intervals is essential. Blower type E 02 SP D 03, E 03 D 04, E 04 2D 04 D 05, E 05 2D 05 D 05, E 05 2D 05 verk. Ausf. D 052, E 052 2D 052 D 060, E 060 2D 060 D 064, E 064 2D 064 D 066, E 066 D 07 D 072 2D 07 D 08 D 082 2D 08 D 09 D 092 Spare filter tissue for fine filter d1 d2 d3 d4 d5 e h1 h2 No. CodeNo. 82 95 105 140 148 4u4,5 120 140 148 4u5,5 – – 112 108 BST 2771 116 108 BST 2381 0420 0072 106 140 202 210 4u5,5 – 133 126 BST 2366 0073 116 147 202 210 4u5,5 – 245 238 BST 2367 0074 116 147 202 210 4u5,5 – 225 218 BST 2383 0564 118 171 190 200 4u5,5 – 242 236 BST 2626 1227 140 176 250 260 4u5,5 – 291 281 BST 2655 1262 147 198 250 260 4u6 – 377 359 BST 2364 0076 222 238 315 315 4u7 24 471 453 BST 2770 01145 180 238 310 315 4u7 – 479 460 BST 2378 0077 240 256 410 410 4u7 40 474 456 BST 2527 0773 275 290 410 410 8u7 – 714 696 BST 2528 0774 Blower type E 02 SP D 03, E 03 D 04, E 04 2D 04 D 05, E 05 2D 05 D 05, E 05 2D 05 verk. Ausf. D 052, E 052 2D 052 D 060, E 060 2D 060 D 064, E 064 2D 064 D 066, E 066 D 07 D 072 2D 07 D 08 D 082 2D 08 D 09 D 092 Dimensions Part No. Code No. 15u104u425 15u104u425 13 395 13 395 0423 0423 15u120u620 13 301 0425 15u230u620 13 236 0659 15u210u620 13 422 0691 15u230u586 14 911 1228 15u265u750 14 250 1263 15u343u750 14 254 0666 15u453u960 13 377 0692 15u445u1220 14 262 0784 15u685u1220 14 268 0785 Dimensions in mm – subject to modifications 38 www.elektror.ru ЗАО "Берг АБ" Тел.: (495)228-06-21, (495)727-22-72 elektror-mail@ya.ru Accessories Fine filter Blower type intake side a b h No. Code no. 235 259 80 BST2424 0430 Rechtslauf 324 379 113 BST2443 0638 Linkslauf 324 379 113 BST2540 075 Dimenstions Part no. Code no. 15u225u250 13 435 0660 15u320u375 13 700 0608 DK 1/2, EK 1/2 DK 2/2 DK 3/2 DK 2/2 DK 3/2 Spare filter tissue Blower type for fine filter DK 1/2, EK 1/2 DK 2/2 DK 3/2 Step switch 2 steps with housing, enclosure IP 54 for three and single phase a.c. Step switch 2 steps without housing, enclosure IP 00, for three and single phase a.c. Blower type Three phase a. c. d l Part no. Code no. D 03 RS – D 072 RS 44 80 13 289 0622 D 082 RS, D 092 RS 50 100 13 719 0685 Blower type Three phase a. c. l Part no. Code no. D 03 RS – D 072 RS 103 13 734 0711 D 082 RS, D 092 RS 103 13 735 0712 Dimensions in mm – subject to modifications 39
Similar documents
Pressure
Type code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 60
More information