Measuring orifice VMO
Transcription
Measuring orifice VMO
Measuring orifice VMO Technical Information · GB 3.1.0.18 Edition 11.11 • • • • • For use as a measuring or restricting orifice Can be combined with valVario valves and regulators Air and gas flow rate diagrams to facilitate configuration Easy installation thanks to flanges with internal thread Replaceable aluminium washers for optimal adjustment to local operating conditions www.kromschroeder.com 2 Table of contents Measuring orifice VMO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Table of contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1 Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.1 Examples of application . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1.1 Self recuperative burner for direct heating systems . . . . . . . 4 1.1.2 Continuous control with pneumatic ratio control system . . 4 2 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3 Flow rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3.1 VMO 110, VMO 115, VMO 120, VMO 125 . . . . . . . . . . . . 6 3.2 VMO 232, VMO 240, VMO 250 . . . . . . . . . . . . . . . . . . . . 7 3.3 kV value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 4 Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 4.1 Type code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 5 Project planning information . . . . . . . . . . . . . . . . . . . . . . 10 5.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 5.2 Gas line connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 6 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 6.1 Seal set VA 1 – 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 6.2 Washer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 7 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 7.1 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 7.1.1 VMO..R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 7.1.2 VMO..N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 7.1.3 VMO 240F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 8 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 VMO · Edition 11.11 t = To be continued 3 1 Application The valVario measuring orifice VMO is installed in gas control and safety systems, as well as in air systems used in industrial and commercial gas heat generation. It can serve as a restricting orifice when used in conjunction with valVario gas solenoid valves and gas control valves. The test points are located in the measuring orifice housing. The measuring orifice VMO is a good-value alternative in areas where no standardized measuring orifice is required. The replaceable washers with different hole sizes allow the orifice to be adjusted perfectly to the local operating conditions. Shaft melting furnace Incineration installation for thermal regenerative flue air purification VMO · Edition 11.11 Application 4 1.1 Examples of application 1.1.2 Continuous control with pneumatic ratio control system 1.1.1 Self recuperative burner for direct heating systems VAS ZIO VMO VAG M VAS..L VMO GEH M EKO EKO LEH LEH VMO IC 20 + BVA VMO BVA+IC Self recuperative burner in a direct heating system with an inductor for evacuating the flue gases from the furnace. The inductor generates a vacuum with a centrally positioned nozzle and thus draws the flue gases out of the furnace chamber through the burner’s heat exchanger. The measuring orifices VMO are designed to record the gas and air flow rates. VMO · Edition 11.11 EKO BVA With this type of control, the mixture setting can be maintained over a wide control range while at the same time preventing air deficiency. This type of control is used in melting furnaces in the aluminium industry or in regenerative incineration installations in the environment industry, for example. Here, the measuring orifice VMO is designed to record the gas flow rate. 5 2 Function Plate bracket Washer Housing Base plate A plate bracket with a washer is placed in the VMO housing. There is a hole in the washer through which gas can flow. For replacing the washer, the base plate of the housing can be removed in order to pull the plate bracket and washer together out of the housing. VMO · Edition 11.11 6 3 Flow rate The characteristic curves are measured at the test points at 15°C (59°F) for the individual washers. 30 8 20 4 3 2.5 2 1.6 10 8 6 5 4 1.2 3 0.8 2 0.4 1 1 0,1 0,2 0,3 2 3 1 0,1 0,8 1 2 0,2 0,3 0,4 0,6 0,1 5 0,5 0,2 0,3 0,4 0,6 7 10 20 30 3 1 1 4 2 2 3 50 70 100 Legend = natural gas (ρ = 0.80 kg/m3) = propane (ρ = 2.01 kg/m3) = air (ρ = 1.29 kg/m3) VMO · Edition 11.11 6 10 100 80 60 50 40 10 30 10 30 8 20 8 20 4 10 8 6 5 4 4 3 2.5 2 1.6 3 2.5 2 1.6 10 8 6 5 4 1.2 3 1.2 3 0.8 2 0.8 2 0.4 1 1 0.4 1 1 3 2 6 V'[m3/h (n)] 3 200 300 V' [SCFH] 1 1 2 3 0,8 1 1 5 2 2 50 70 100 3 3 4 8 10 4 20 6 6 200 300 30 40 10 10 20 20 500 700 1000 30 60 100 30 60 V'[m3/h (n)] 2000 3000 V' [SCFH] 10 mm 12 mm 14 m 16 m mm VMO 125 40 32 24 20 16 ∆p [mbar] 100 80 60 50 40 ∆p [inch WC] ∆p [mbar] 40 32 24 20 16 2 3 1 1 20 mm 8 mm 10 VMO 120 ∆p [inch WC] 100 80 60 50 40 6m m ∆p [mbar] ∆p [inch WC] VMO 110, VMO 115 40 32 24 20 16 6m m 8m m 10 mm 12 mm 4m m 5m m 3.1 VMO 110, VMO 115, VMO 120, VMO 125 1 2 3 0,8 1 1 5 2 2 50 70 100 3 3 4 8 10 4 20 6 6 200 300 30 40 10 10 20 20 500 700 1000 30 60 100 30 60 V'[m3/h (n)] 2000 3000 V' [SCFH] Flow rate 7 100 80 60 50 40 10 30 10 30 10 30 8 20 8 20 8 20 4 10 8 6 5 4 4 3 2.5 2 1.6 10 8 6 5 4 4 3 2.5 2 1.6 3 2.5 2 1.6 10 8 6 5 4 1.2 3 1.2 3 1.2 3 0.8 2 0.8 2 0.8 2 0.4 1 1 0.4 1 1 0.4 1 1 2 3 1 10 20 30 8 10 10 50 20 20 500 700 1000 80 100 30 40 30 40 60 60 200 300 400 600 1000 100 100 2000 3000 5000 200 300 200 300 10000 Legend = natural gas (ρ = 0.80 kg/m3) = propane (ρ = 2.01 kg/m3) = air (ρ = 1.29 kg/m3) VMO · Edition 11.11 600 V'[m3/h (n)] 30000 V' [SCFH] 2 3 1 10 20 30 8 10 10 50 20 20 500 700 1000 80 100 30 40 30 40 60 60 200 300 400 600 1000 100 100 2000 3000 5000 200 300 200 300 10000 32 34 mm mm 38 mm VMO 250 40 32 24 20 16 ∆p [mbar] 100 80 60 50 40 ∆p [inch WC] VMO 240 40 32 24 20 16 ∆p [mbar] 100 80 60 50 40 ∆p [inch WC] ∆p [mbar] ∆p [inch WC] VMO 232 40 32 24 20 16 16 mm 20 mm 24 mm 28 mm 32 mm 16 mm 20 m 24 m mm 3.2 VMO 232, VMO 240, VMO 250 600 V'[m3/h (n)] 30000 V' [SCFH] 2 3 1 10 20 30 8 10 10 50 20 20 500 700 1000 80 100 30 40 30 40 60 60 200 300 400 600 1000 100 100 2000 3000 5000 200 300 200 300 10000 600 V'[m3/h (n)] 30000 V' [SCFH] Flow rate 8 3.3 kV value The measuring orifice is determined using the flow rate diagram or by calculation using the kv value. Measuring orifice Nominal flange size VMO 110 DN 10 VMO 115 DN 15 VMO 120 DN 20 VMO 125 DN 25 VMO 232 DN 32 VMO 240 DN 40 VMO 250 DN 50 Hole diameter Washer [mm] 4 5 6 4 5 6 6 8 10 12 10 12 14 16 18 20 16 20 24 16 20 24 28 32 32 34 38 V· (n)= Flow rate (standard state) [m3/h] kV = Valve coefficient (see table) ∆p = Pressure loss [bar] pa = Outlet pressure (absolute) [bar] VMO · Edition 11.11 ρn = Density [kg/m3] (air 1.29/natural gas 0.80/propane 2.01/butane 2.71) T = Medium temperature (absolute) [K] kV [m3/h] 0.5 0.7 1.1 0.5 0.7 1.1 1.0 1.7 2.6 3.8 2.5 3.7 5.2 6.9 9.0 12.2 7.2 10.5 12.5 7.1 10.5 15.5 21.7 30.6 28.7 34.3 50.7 Example We want to find the hole diameter for the washer and the nominal flange diameter for a measuring orifice VMO. We have the maximum flow rate V· (n) max, the outlet pressure pa and the temperature T for the medium of natural gas. V· (n) max. = 37 m3/h pa = 30 mbar = 0.03 bar ⇒ pa absolute = 0.03 bar + 1 bar = 1.03 bar ∆pmax. = 0.01 bar (desired) T = 20°C ⇒ Tabsolute = 20 + 273 K = 293 K kv = 37 · 514 0.83 · 293 0.01 · 1.03 = 11.1 m3/h The measuring orifice with the next higher kv value is to be selected (see table): e.g. VMO 125 with a washer hole diameter of 20 mm. 9 4 Selection Type VMO 110 VMO 115 VMO 120 VMO 125 VMO 232 VMO 240 VMO 250 R N F – – – – – – 05 M 04 05 06 08 – – – – – – – – – – – – – – – – – – – – 10 – – – – – = standard, = available 4.1 Type code Code VMO 1–2 – 10–50 R N F 05 M 04 – 38 Description Measuring orifice Size Without inlet and outlet flange Nominal inlet and outlet diameter in DN Rp internal thread NPT internal thread Flange to ISO 7005 pe max 500 mbar With pressure test points Orifice diameter* in mm * Delivery of washers with individual orifice diameter on request. VMO · Edition 11.11 12 – – – – – 14 – – – – – – 16 – – – – 18 – – – – – – 20 24 28 32 34 38 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – Order example VMO 115R05M05 10 5 Project planning information 5.2 Gas line connection 5.1 Installation In order to take accurate measurements of the pressure differential on the measuring orifice VMO, it must be ensured that there is an undisturbed flow of gas at the inlet and outlet for a distance of ≥ 5 × DN. ≥ 5 DN ≥ 5 DN Installation position: VMO can be installed as required. When fitting to pressure regulator VAD, VAG or VAV, the base plate must be facing the same direction as the regulator body. Installation position when using other valVario controls: VMO can be installed downstream of the valVario control or can be fitted as a standalone device in the pipe. VMO · Edition 11.11 11 6 Accessories Orifice 6.1 Seal set VA 1 – 3 A B C D Scope of delivery: A 1 x double block seal, B 2 x O-rings (flange), C 2 x O-rings (pressure switch), D 2 x sealing rings (test point). 6.2 Washer For installing in the plate bracket of measuring orifice VMO. The hole diameter is engraved on the washer. Supply including the new seal for the base plate. VMO · Edition 11.11 VMO1 D4 /B VMO1 D5 /B VMO1 D6 /B VMO1 D8 /B VMO1 D10 /B VMO1 D12 /B VMO1 D14 /B VMO1 D16 /B VMO1 D18 /B VMO1 D20 /B VMO1 Dx /B* VMO2 D16 /B VMO2 D20 /B VMO2 D24 /B VMO2 D28 /B VMO2 D32 /B VMO2 D34 /B VMO2 D38 /B VMO2 Dx /B * Hole diameter on request. Hole dia. [mm] 4 5 6 8 10 12 14 16 18 20 xx* 16 20 24 28 32 34 38 xx* Order No. 74923803 74923804 74923805 74923806 74923807 74923808 74923809 74923810 74923811 74923812 74923813 74923814 74923815 74923816 74923817 74923818 74923819 74923820 74923821 12 7 Technical data Gas types: natural gas, LPG (gaseous), biologically produced methane (max. 0.1 %-by-vol. H2S) or air; other gases on request. The gas must be dry in all conditions and must not contain condensate. Max. inlet pressure pe: max. 500 mbar (7.25 psig). Ambient temperature: -20 to +60°C (-4 to +140°F), no condensation permitted. Storage temperature: 0 to +40°C (-4 to +104°F). Housing: aluminium. Connection flanges with internal thread: Rp to ISO 7-1, NPT to ANSI/ASME. VMO · Edition 11.11 Technical data 13 7.1 Dimensions H1 H2 D VMO..R, VMO..N 7.1.1 VMO..R Type VMO 110 VMO 115 VMO 120 VMO 125 VMO 225 VMO 232 VMO 240 VMO 250 7.1.2 VMO..N Connection Rp 3/8 1/2 3/4 1 1 11/4 11/2 2 DN 10 15 20 25 25 32 40 50 L1 mm 30 30 30 30 34 34 34 34 Dimensions F D H1 mm mm mm 15 62.7 65,1 15 62.7 65,1 23 62.7 65,1 23 62.7 65,1 29 88 81 29 88 81 29 88 81 29 88 81 * Without flanges and connection parts. VMO · Edition 11.11 F F L1 H2 mm 44,6 44,6 44,6 44,6 65,2 65,2 65,2 65,2 Weight* kg 0.245 0.245 0.245 0.245 0.505 0.505 0.505 0.505 Type VMO 110 VMO 115 VMO 120 VMO 125 VMO 225 VMO 232 VMO 240 VMO 250 Connection NPT 3/8 1/2 3/4 1 1 11/4 11/2 2 DN 10 15 20 25 25 32 40 50 L1 inch 1,18 1,18 1,18 1,18 1,34 1,34 1,34 1,34 Dimensions F D H1 inch inch inch 0,59 2,46 2,56 0,59 2,46 2,56 0,91 2,46 2,56 0,91 2,46 2,56 1,14 3,46 3,19 1,14 3,46 3,19 1,14 3,46 3,19 1,14 3,46 3,19 * Without flanges and connection parts. H2 inch 1,75 1,75 1,75 1,75 2,57 2,57 2,57 2,57 Weight* lbs 0,54 0,54 0,54 0,54 1,11 1,11 1,11 1,11 Technical data > Dimensions 14 D H1 H2 F L1 F 7.1.3 VMO 240F Type Connection VMO 240 DN 40 Dimensions L1 F D H1 H2 mm mm mm mm mm 34 66 88 81 65,2 * Without flanges and connection parts. VMO · Edition 11.11 Weight* kg 0.505 VMO 240F 15 8 Maintenance Check for external tightness at least once per annum, at least twice per annum for operation with biologically produced methane. VMO · Edition 11.11 16 Feedback Finally, we are offering you the opportunity to assess this “Technical Information (TI)” and to give us your opinion, so that we can improve our documents further and suit them to your needs. Clarity Found information quickly Searched for a long time Didn’t find information What is missing? No answer Comprehension Coherent Too complicated No answer Scope Too little Sufficient Too wide No answer Use To get to know the product To choose a product Planning To look for information Navigation I can find my way around I got “lost” No answer My scope of functions Technical department Sales No answer Remarks Kromschröder AG Michael Rehkamp m.rehkamp@kromschroeder.com Osnabrück (Adobe Reader 7 or higher required) www.adobe.com Elster GmbH Postfach 2809 · 49018 Osnabrück Strotheweg 1 · 49504 Lotte (Büren) Germany T +49 541 1214-0 F +49 541 1214-370 info@kromschroeder.com www.kromschroeder.com www.elster.com VMO · Edition 11.11 The current addresses of our international agents are available on the Internet: www.kromschroeder.de/index.php?id=718&L=1 We reserve the right to make technical modifications in the interests of progress. Copyright © 2011 Elster Group All rights reserved. 03250928 Contact