CDW7 Air Circuit Breaker

Transcription

CDW7 Air Circuit Breaker
S
International Catalogue 2011
Delixi Electric: Who are we
A global company at your service
Delixi was founded in 1984 in Zhejiang province with sales over 1.5BM€,employing more than 15000 people.
Delixi created an international Joint Venture in November 2007,named Delixi Electric Ltd., in order to serve you
worldwide,with core LV products having the right quality at the right price.
Our products are designed for Residential/Building/Energy/infrastructure and Industrial markets.Delixi Electric
employs 5200 people world wide.
A reliable company serving you with reliable product
Dedicated R&D center
International quality control of suppliers
International quality control of plants
Fully automatized distribution center
Network of recognized 600 distributors
world wide
Ⅰ
Reliable Quality
For more details, please contact your local Delixi Electrc Company.
Ⅱ
Ⅲ
Contents
Residual Current
Devices
33-36
Accessories for
MCB&RCBO
37-40
Control Devices
41-42
Surge Protective
Devices
43-47
Distribution Box
Low-voltage
Low-voltage
Distribution
Distribution
64-82
48-63
Molded Case
Circuit Breaker
Final Distribution
19-32
3-18
Miniature Circuit
Breakers&Switch
Disconnectors
Air Circuit Breaker
Motor Control &
Protection
128-134
86-127
Contactor&Thermal
Overload Relay
135-146
Definite-purpose
Contactors
Relays
Management
Power
Energy
Power Energy
Management
148-150
151-163
Current Transformer
164-167
Meter
Digital Time Switch
168-174
Voltage Stabilizer
Industrial Control
Components
175-202
Control Signal
203-208
Fuse
209
Cable Connector
210-215
Industrial Plug&
Socket
216-220
Copper Terminal
Block Series
221
Din-rail
1
Contents
Final Distribution
Miniature Circuit Breaker & Switch Disconnectors 3-18
Final Distribution
CDB6
18mm Miniature Circuit Breaker
4
CDB6s
18mm Miniature Circuit Breaker
8
CDB2
27mm Miniature Circuit Breaker
12
CDB3
Phase-neutral Circuit Breaker
15
CDB5
Switch Disconnector
17
Residual Current Devices
19-32
CDB6LE
Residual Current Operated Circuit Breaker
20
CDB6v
Residual Current Protection Module
23
CDB2LE
Residual Current Operated Circuit Breaker
26
CDB3LE
Residual Current Operated Circuit Breaker
29
CDL7
Electromagnetic Type Residual Current Switch
31
Accessories for MCB&RCBO
33-36
SD,OF,MX+OF
33
Busbar
36
Control Devices
37-40
1~5
CDCH8
Modular Contactor
37
CDRT8
Time Relay
39
Surge Protective Devices
41-42
CDY1
41
Surge Protective Devices
1~5
2
Distribution Box
43-47
CDPZ50 Series
Lighting Distribution Box
43
JXF
Power Distribution Box
45
Miniature Circuit Breaker & Switch Disconnectors
Product Overview
18mm MCB
27mm MCB
Final Distribution
CDB6
CDB6s
S
4
In: 1-63A
Breaking Capacity: 3/4.5 kA
In: 1-63A
Breaking Capacity: 4.5/6 kA
A
18mm 1P+N MCB
CDB3
CDB2
12
In: 63-125A
Breaking Capacity: 10kA
Switch Disconnectors
CDB5
15
In: 6-32A
Breaking Capacity: 3kA
Accessories page**
MX+OF
8
17
In: 20-100A
*
33
SD
OF
3
CDB6 18mm Miniature Circuit Breaker
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 3000 /4500A
Function
RoHS
CDB6 miniature circuit breaker combine the following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation
Final Distribution
Order Information
Type
Breaking
Capacity
(kA)
Rating
Width
(A)
1P
3
1
3
6
10
16
20
25
32
40
50
63
2
2
2
2
2
2
2
2
2
2
2
4.5
1
3
6
10
16
20
25
32
40
50
63
3
1
3
6
10
16
20
25
32
40
50
63
2P
B curve
C curve
D curve
CDB6a1B1
CDB6a1B3
CDB6a1B6
CDB6a1B10
CDB6a1B16
CDB6a1B20
CDB6a1B25
CDB6a1B32
CDB6a1B40
CDB6a1B50
CDB6a1B63
CDB6a1C1
CDB6a1C3
CDB6a1C6
CDB6a1C10
CDB6a1C16
CDB6a1C20
CDB6a1C25
CDB6a1C32
CDB6a1C40
CDB6a1C50
CDB6a1C63
CDB6a1D1
CDB6a1D3
CDB6a1D6
CDB6a1D10
CDB6a1D16
CDB6a1D20
CDB6a1D25
CDB6a1D32
CDB6a1D40
CDB6a1D50
CDB6a1D63
2
2
2
2
2
2
2
2
2
2
2
CDB6L1B1
CDB6L1B3
CDB6L1B6
CDB6L1B10
CDB6L1B16
CDB6L1B20
CDB6L1B25
CDB6L1B32
CDB6L1B40
CDB6L1B50
CDB6L1B63
CDB6L1C1
CDB6L1C3
CDB6L1C6
CDB6L1C10
CDB6L1C16
CDB6L1C20
CDB6L1C25
CDB6L1C32
CDB6L1C40
CDB6L1C50
CDB6L1C63
CDB6L1D1
CDB6L1D3
CDB6L1D6
CDB6L1D10
CDB6L1D16
CDB6L1D20
CDB6L1D25
CDB6L1D32
CDB6L1D40
CDB6L1D50
CDB6L1D63
4
4
4
4
4
4
4
4
4
4
4
CDB6a2B1
CDB6a2B3
CDB6a2B6
CDB6a2B10
CDB6a2B16
CDB6a2B20
CDB6a2B25
CDB6a2B32
CDB6a2B40
CDB6a2B50
CDB6a2B63
CDB6a2C1
CDB6a2C3
CDB6a2C6
CDB6a2C10
CDB6a2C16
CDB6a2C20
CDB6a2C25
CDB6a2C32
CDB6a2C40
CDB6a2C50
CDB6a2C63
CDB6a2D1
CDB6a2D3
CDB6a2D6
CDB6a2D10
CDB6a2D16
CDB6a2D20
CDB6a2D25
CDB6a2D32
CDB6a2D40
CDB6a2D50
CDB6a2D63
Note: Width refers to multiple of 9 mm.
4
Reference
CDB6 18mm Miniature Circuit Breaker
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 3000 /4500A
RoHS
Order Information
Type
4P
Rating
Width
(A)
Reference
B curve
C curve
D curve
4.5
1
3
6
10
16
20
25
32
40
50
63
4
4
4
4
4
4
4
4
4
4
4
CDB6L2B1
CDB6L2B3
CDB6L2B6
CDB6L2B10
CDB6L2B16
CDB6L2B20
CDB6L2B25
CDB6L2B32
CDB6L2B40
CDB6L2B50
CDB6L2B63
CDB6L2C1
CDB6L2C3
CDB6L2C6
CDB6L2C10
CDB6L2C16
CDB6L2C20
CDB6L2C25
CDB6L2C32
CDB6L2C40
CDB6L2C50
CDB6L2C63
CDB6L2D1
CDB6L2D3
CDB6L2D6
CDB6L2D10
CDB6L2D16
CDB6L2D20
CDB6L2D25
CDB6L2D32
CDB6L2D40
CDB6L2D50
CDB6L2D63
3
1
3
6
10
16
20
25
32
40
50
63
6
6
6
6
6
6
6
6
6
6
6
CDB6a3B1
CDB6a3B3
CDB6a3B6
CDB6a3B10
CDB6a3B16
CDB6a3B20
CDB6a3B25
CDB6a3B32
CDB6a3B40
CDB6a3B50
CDB6a3B63
CDB6a3C1
CDB6a3C3
CDB6a3C6
CDB6a3C10
CDB6a3C16
CDB6a3C20
CDB6a3C25
CDB6a3C32
CDB6a3C40
CDB6a3C50
CDB6a3C63
CDB6a3D1
CDB6a3D3
CDB6a3D6
CDB6a3D10
CDB6a3D16
CDB6a3D20
CDB6a3D25
CDB6a3D32
CDB6a3D40
CDB6a3D50
CDB6a3D63
4.5
1
3
6
10
16
20
25
32
40
50
63
6
6
6
6
6
6
6
6
6
6
6
CDB6L3B1
CDB6L3B3
CDB6L3B6
CDB6L3B10
CDB6L3B16
CDB6L3B20
CDB6L3B25
CDB6L3B32
CDB6L3B40
CDB6L3B50
CDB6L3B63
CDB6L3C1
CDB6L3C3
CDB6L3C6
CDB6L3C10
CDB6L3C16
CDB6L3C20
CDB6L3C25
CDB6L3C32
CDB6L3C40
CDB6L3C50
CDB6L3C63
CDB6L3D1
CDB6L3D3
CDB6L3D6
CDB6L3D10
CDB6L3D16
CDB6L3D20
CDB6L3D25
CDB6L3D32
CDB6L3D40
CDB6L3D50
CDB6L3D63
3
1
3
6
10
16
20
25
32
40
50
63
8
8
8
8
8
8
8
8
8
8
8
CDB6a4B1
CDB6a4B3
CDB6a4B6
CDB6a4B10
CDB6a4B16
CDB6a4B20
CDB6a4B25
CDB6a4B32
CDB6a4B40
CDB6a4B50
CDB6a4B63
CDB6a4C1
CDB6a4C3
CDB6a4C6
CDB6a4C10
CDB6a4C16
CDB6a4C20
CDB6a4C25
CDB6a4C32
CDB6a4C40
CDB6a4C50
CDB6a4C63
CDB6a4D1
CDB6a4D3
CDB6a4D6
CDB6a4D10
CDB6a4D16
CDB6a4D20
CDB6a4D25
CDB6a4D32
CDB6a4D40
CDB6a4D50
CDB6a4D63
Final Distribution
3P
Breaking
Capacity
(kA)
Note: Width refers to multiple of 9 mm.
5
CDB6 18mm Miniature Circuit Breaker
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 3000 /4500A
RoHS
Order Information
Type
Breaking
Capacity
(kA)
Reference
Rating
Width
(A)
1
8
3
8
6
8
10
8
16
8
20
8
25
8
32
8
40
8
50
8
63
8
Note: Width refers to multiple of 9 mm.
Final Distribution
4.5
B curve
C curve
D curve
CDB6L4B1
CDB6L4B3
CDB6L4B6
CDB6L4B10
CDB6L4B16
CDB6L4B20
CDB6L4B25
CDB6L4B32
CDB6L4B40
CDB6L4B50
CDB6L4B63
CDB6L4C1
CDB6L4C3
CDB6L4C6
CDB6L4C10
CDB6L4C16
CDB6L4C20
CDB6L4C25
CDB6L4C32
CDB6L4C40
CDB6L4C50
CDB6L4C63
CDB6L4D1
CDB6L4D3
CDB6L4D6
CDB6L4D10
CDB6L4D16
CDB6L4D20
CDB6L4D25
CDB6L4D32
CDB6L4D40
CDB6L4D50
CDB6L4D63
Technical Data
MCB
CDB6 18mm Circuit Breaker
IEC60898-1
CB, CE, RoHS
Standard
Certification
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
1-4P
1,3,6,10,16,20,25,32,40,50,63A
230/400V AC
500V
Breaking Capacity Icn
Electrical
Features
Rate current(A)
Poles
Voltage(V)
Breaking capactiy Icn(KA)
1-63
1P
2P, 3P, 4P
230/400
400
3/4.5
3/4.5
Tripping Curve(see following tripping curve pictures)
B Curve:the magnetic release operates between 3 and 5 In
C Curve:the magnetic release operates between 5 and 10 In
D Curve:the magnetic release operates between 10 and 14 In
Mechanical
Features
2
Connection
Installation
Up to 25mm cables
Rate
Current(A)
Screw
Rated Torque
(Nm)
Limiting Torque
(Nm)
1-63
M5
2.5
4.5
Mounting
Accessories
35mm Din-rail
Contact Accessory
Fault-indicating Accessory
Shunt -trip release
6
4000 times
10000 times
2
treatment 2
~ 40℃
-5℃~+
Electrical Durability
Mechanical Durability
Protection Degree
Tropicalization
Ambient Temperature
OF
SD
MX+OF
CDB6 18mm Miniature Circuit Breaker
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 3000 /4500A
RoHS
Tripping Curve
CDB6 Miniature Circuit Breaker
Final Distribution
Overall Dimensions
Accessory
The Sketch Map of Installation with Breakers
SD
OF
CDB6
MX+OF
7
CDB6s 18mm Miniature Circuit Breaker
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 4500 /6000A
Function
CDB6s miniature circuit breakers combine the following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation
Final Distribution
Order Information
Type
Rating
Width
(A)
1P
1
2P
Reference
B curve
C curve
D curve
2
CDB6s1B1
CDB6s1C1
CDB6s1D1
2
2
CDB6s1B2
CDB6s1C2
CDB6s1D2
3
2
CDB6s1B3
CDB6s1C3
CDB6s1D3
4
2
CDB6s1B4
CDB6s1C4
CDB6s1D4
5
2
CDB6s1B5
CDB6s1C5
CDB6s1D5
6
2
CDB6s1B6
CDB6s1C6
CDB6s1D6
8
2
CDB6s1B8
CDB6s1C8
CDB6s1D8
10
2
CDB6s1B10
CDB6s1C10
CDB6s1D10
13
2
CDB6s1B13
CDB6s1C13
CDB6s1D13
16
2
CDB6s1B16
CDB6s1C16
CDB6s1D16
20
2
CDB6s1B20
CDB6s1C20
CDB6s1D20
25
2
CDB6s1B25
CDB6s1C25
CDB6s1D25
32
2
CDB6s1B32
CDB6s1C32
CDB6s1D32
40
2
CDB6s1B40
CDB6s1C40
CDB6s1D40
50
2
CDB6s1B50
CDB6s1C50
CDB6s1D50
63
2
CDB6s1B63
CDB6s1C63
CDB6s1D63
1
4
CDB6s2B1
CDB6s2C1
CDB6s2D1
2
4
CDB6s2B2
CDB6s2C2
CDB6s2D2
3
4
CDB6s2B3
CDB6s2C3
CDB6s2D3
4
4
CDB6s2B4
CDB6s2C4
CDB6s2D4
5
4
CDB6s2B5
CDB6s2C5
CDB6s2D5
6
4
CDB6s2B6
CDB6s2C6
CDB6s2D6
8
4
CDB6s2B8
CDB6s2C8
CDB6s2D8
10
4
CDB6s2B10
CDB6s2C10
CDB6s2D10
13
4
CDB6s2B13
CDB6s2C13
CDB6s2D13
16
4
CDB6s2B16
CDB6s2C16
CDB6s2D16
20
4
CDB6s2B20
CDB6s2C20
CDB6s2D20
25
4
CDB6s2B25
CDB6s2C25
CDB6s2D25
32
4
CDB6s2B32
CDB6s2C32
CDB6s2D32
40
4
CDB6s2B40
CDB6s2C40
CDB6s2D40
50
4
CDB6s2B50
CDB6s2C50
CDB6s2D50
63
4
CDB6s2B63
CDB6s2C63
CDB6s2D63
Note: Width refers to multiple of 9 mm.
8
CDB6s 18mm Miniature Circuit Breaker
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 4500 /6000A
Order Information
Rating
Width
(A)
Reference
B curve
C curve
D curve
3P
1
6
CDB6s3B1
CDB6s3C1
CDB6s3D1
2
6
CDB6s3B2
CDB6s3C2
CDB6s3D2
3
6
CDB6s3B3
CDB6s3C3
CDB6s3D3
4
6
CDB6s3B4
CDB6s3C4
CDB6s3D4
5
6
CDB6s3B5
CDB6s3C5
CDB6s3D5
6
6
CDB6s3B6
CDB6s3C6
CDB6s3D6
8
6
CDB6s3B8
CDB6s3C8
CDB6s3D8
10
6
CDB6s3B10
CDB6s3C10
CDB6s3D10
13
6
CDB6s3B13
CDB6s3C13
CDB6s3D13
16
6
CDB6s3B16
CDB6s3C16
CDB6s3D16
20
6
CDB6s3B20
CDB6s3C20
CDB6s3D20
25
6
CDB6s3B25
CDB6s3C25
CDB6s3D25
32
6
CDB6s3B32
CDB6s3C32
CDB6s3D32
40
6
CDB6s3B40
CDB6s3C40
CDB6s3D40
50
6
CDB6s3B50
CDB6s3C50
CDB6s3D50
63
6
CDB6s3B63
CDB6s3C63
CDB6s3D63
1
8
CDB6s4B1
CDB6s4C1
CDB6s4D1
2
8
CDB6s4B2
CDB6s4C2
CDB6s4D2
3
8
CDB6s4B3
CDB6s4C3
CDB6s4D3
4
8
CDB6s4B4
CDB6s4C4
CDB6s4D4
5
8
CDB6s4B5
CDB6s4C5
CDB6s4D5
6
8
CDB6s4B6
CDB6s4C6
CDB6s4D6
8
8
CDB6s4B8
CDB6s4C8
CDB6s4D8
10
8
CDB6s4B10
CDB6s4C10
CDB6s4D10
13
8
CDB6s4B13
CDB6s4C13
CDB6s4D13
16
8
CDB6s4B16
CDB6s4C16
CDB6s4D16
20
8
CDB6s4B20
CDB6s4C20
CDB6s4D20
25
8
CDB6s4B25
CDB6s4C25
CDB6s4D25
32
8
CDB6s4B32
CDB6s4C32
CDB6s4D32
40
8
CDB6s4B40
CDB6s4C40
CDB6s4D40
50
8
CDB6s4B50
CDB6s4C50
CDB6s4D50
63
8
CDB6s4B63
CDB6s4C63
CDB6s4D63
4P
Final Distribution
Type
Note: Width refers to multiple of 9 mm.
9
CDB6s 18mm Miniature Circuit Breaker
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 4500 /6000A
Technical Data
MCB
CDB6s 18mm Circuit Breaker
Final Distribution
Standard
IEC 60898-1
Certitication
KEMA CB CE RoHS
poles
1-4P
Rated Current In
1, 2, 3, 4, 5, 6, 8, 10, 13, 16, 20, 25, 32, 40, 50, 63
Rated Voltage Ue
230/400V AC
Insulation Voltage Ui
500V AC
Breaking Capacity Icn
Electrical
Features
Rate
current(A)
Breaking
1-40
6
B,C
1P
2P, 3P, 4P
230/400
400
50,63
4.5
B,C
1P
2P, 3P, 4P
230/400
400
1-63
4.5
D
1P
2P, 3P, 4P
230/400
400
Type
Poles
Voltage
capacity lcn(kA)
(V)
Tripping Curve ( see following tripping curve pictures)
B curve;the magnetic release operates between 3 and 5 In
C curve;the magnetic release operates between 5 and 10 In
D curve;the magnetic release operates between 10 and 14 In
Mechanical
Features
Electrical Durability
4000 times
Mechanical Durability
10000 times
Protection Degree
2
Tropicalization
treatment 2
Ambient Temperture
~ + 40℃
-5℃~
Connection
Installation
Up to 25mm2 cables
Rate
current(A)
Screw
Rated Torque
(Nm)
Limiting Torque
(Nm)
1-63
M5
2.5
4.5
Mounting
Accessories
10
35mm Din-rail
Contact Accessory
OF
Fault-indicating Accessory
SD
Shunt-trip Release
MX+OF
CDB6s 18mm Miniature Circuit Breaker
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 4500 /6000A
Tripping Curves
Final Distribution
Overall Dimensions
Unit: mm
88 max
: 67.21–0.43
Accessory
SD
OF
CDB6s
MX+OF
11
CDB2 27mm Miniature Circuit Breaker
Standard: IEC 60947-2
Trip Curve: C and D curves
Breaking Capacity: 10000A
Function
CDB2 miniature circuit breaker combine the following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation
Final Distribution
Order Information
12
Type
Rating
(A)
Width
(in mod.of 9mm)
Reference
C curve
D curve
1P
63
80
100
125
3
3
3
3
CDB2H1C63
CDB2H1C80
CDB2H1C100
CDB2H1C125
CDB2H1D63
CDB2H1D80
CDB2H1D100
CDB2H1D125
2P
63
80
100
125
6
6
6
6
CDB2H2C63
CDB2H2C80
CDB2H2C100
CDB2H2C125
CDB2H2D63
CDB2H2D80
CDB2H2D100
CDB2H2D125
3P
63
80
100
125
9
9
9
9
CDB2H3C63
CDB2H3C80
CDB2H3C100
CDB2H3C125
CDB2H3D63
CDB2H3D80
CDB2H3D100
CDB2H3D125
4P
63
80
100
125
12
12
12
12
CDB2H4C63
CDB2H4C80
CDB2H4C100
CDB2H4C125
CDB2H4D63
CDB2H4D80
CDB2H4D100
CDB2H4D125
CDB2 27mm Miniature Circuit Breaker
Standard: IEC 60947-2
Trip Curve: C and D curves
Breaking Capacity: 10000A
Technical Data
MCB
CDB2 27mm Circuit Breaker
IEC60947-2
Certification
CB, SEMKO, CE
Poles
1-4P
Rated Current In
63,80,100,125A
Rated Voltage Ue
230/400V AC
Insulation Voltage Ui
500V
Electrical
Final Distribution
Standard
Breaking Capacity Icn
Features
Rating
(A)
Poles
Voltage
(V)
Breaking capacity
(kA)
63~125
1P
2P,3P,4P
230
400
10
10
Tripping Curve (see following tripping curve pictures)
C curve the magnetic release operates between 5 and 10 In
D curve the magnetic release operates between 10 and 14 In
Electrical Durability
Mechanical
Features
Mechanical Durability
Protection Degree
2
Tropicalization
treatment 2
Ambient Temperature
-5℃~+40℃
~
Up to 50mm cables
2
Connection
Installation
Rate
current(A)
Screw
Rated Torque
(Nm)
Limiting Torque
(Nm)
63-125
M7
4
5.5
Mounting
Accessories
35mm Din-rail
Contact Accessory:
OF
Shunt-trip Release:
MX+OF
13
CDB2 27mm Miniature Circuit Breaker
Standard: IEC 60947-2
Trip Curve: C and D curves
Breaking Capacity: 10000A
Tripping Curves
Final Distribution
Overall Dimensions
Accessories
MX+OF
14
OF
CDB2
CDB3 Phase-neutral Circuit Breaker
Standard: IEC 60898-1
Trip Curve: C curves
Breaking Capacity: 3000A
Function
CDB3 phase-neutral circuit breakers combine the following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation
1P+N
Final Distribution
Order Information
6
2
CDB3a5C6
10
2
CDB3a5C10
16
2
CDB3a5C16
20
2
CDB3a5C20
25
2
CDB3a5C25
32
2
CDB3a5C32
Technical Data
CDB3 18mm Circuit Breaker
MCB
Electrical
Features
Standard
IEC60898-1
Certification
CE
Poles
1P+N
Rated Current In
6,10,16,20,25,32A
Rated Voltage Ue
230V AC
Insulation Voltage Ui
500V
Breaking Capacity Icn
3KA
Tripping Curve (see following tripping curve pictures)
C curve:the magnetic release operates between 5 and 10In
Mechanical
Features
Electrical Durability
4000 times
Mechanical Durability
16000 times
Protection Degree
2
Tropicalization
treatment 2
Ambient Temperature
-5℃~+40℃
Up to 10mm cables
2
Connection
Installation
Rate
current(A)
6-32
Mounting
Screw
M4
Rated Torque
(Nm)
2
Limiting Torque
(Nm)
3
35mm Din-rail
15
CDB3 Phase-neutral Circuit Breaker
Standard: IEC 60898-1
Trip Curve: C curves
Breaking Capacity: 3000A
Tripping Curves
10000
5000
1h
2000
1000
Final Distribution
500
200
100
50
20
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001
0.5
1
2
3 4 5
7 10
20 30
50 70 100
Overall Dimensions
16
200
CDB5 Switch Disconnector
Standard: IEC 60947-3
Function
CDB5 switch disconnectorscombine
combinethe
thefollowing
followingfunctions:
functions:
Making and breaking normal load circuits
Isolation
Order Information
Voltage
(V)
Rating
(A)
Width
(in mod.of 9mm)
Reference
1P
230
20
32
63
100
2
2
2
2
CDB5120
CDB5132
CDB5163
CDB51100
2P
400
20
32
63
100
4
4
4
4
CDB5220
CDB5232
CDB5263
CDB52100
3P
400
20
32
63
100
6
6
6
6
CDB5320
CDB5332
CDB5363
CDB53100
4P
400
20
32
63
100
8
8
8
8
CDB5420
CDB5432
CDB5463
CDB54100
Final Distribution
Type
17
CDB5 Switch Disconnector
Standard: IEC 60947-3
Technical Data
CDB5 Switch Disconnector
Switch Disconnector
Final Distribution
Electrical
Features
Mechanical
Features
Standard
IEC60947-3
Poles
1-4P
Rated Current In
20,32,63,100A
Rated Voltage Ue
230/400V AC
Insulation Voltage Ui
500V
Rated Short-circuit
Making Capacity
1066A(Ie:20~63A)
Short-time Withstand
756A(Ie:20~63A)
Capacity for 1s
1200A(Ie:100A),1s
Electrical Durability
1500 times
Mechanical Durability
8500 times
Protection Degree
2
Ambient Temperature
-5℃~+40℃
Tropicalization
treatment 2
1692A(Ie:100A), Peak current
Storage Temperature
Up to 50mm cables
Connection
Installation
Rate
current(A)
Screw
Rated Torque
(Nm)
Limiting Torque
(Nm)
20-100
M7
4
5.5
Mounting
Overall Dimensions
18
-25℃~+55℃
2
35mm Din-rail
Residual Current Devices Overview
Add-on RCD
18mm RCBO
Final Distribution
CDB6LE
20
CDB6v
23
Sensitivity: 30,50,100,200,300mA
Sensitivity: 30,100,300mA
In: 6-60A
In: V32A, V63A
Breaking Capacity: 3kA
Poles: 1P+N, 2P, 3P, 3P+N, 4P
Poles: 1P+N, 2P, 3P, 3P+N, 4P
27mm RCBO
CDB2LE
Phase-neutral RCBO
26
Sensitivity: 30,100,300mA
In: 63-100A
Breaking Capacity: 10kA
Poles: 1P+N, 2P, 3P, 3P+N, 4P
CDB3LE
29
Sensitivity: 30mA
In: 6-40A
Breaking Capacity: 4.5kA
Poles: 1P+N
RCCB
CDL7
31
Sensitivity:10,30,100,300mA
In: 25-100A
Poles: 2P,4P
19
CDB6LE Residual Current Operated Circuit Breaker
Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 3000A
Sensitivity: 30,50,100,200,300mA
Function
Final Distribution
CDB6LE electronic type residual current operated circuit breakers combine the following functions:
Overload protection
Protection against short-circuit current
Protection for users against indirect contact
Additional protection for users against direct contacts (30mA)
Protection for electrical installations against insulation faults (fire hazard, etc)
Isolation
Order Information
Type
Voltage
(V)
Sensitivity
(mA)
Rating
(A)
Width
Reference
C curve
1P+N
230
30
6
10
16
20
25
32
40
50
60
5
5
5
5
5
5
6
6
6
CDB6LEa1C6S
CDB6LEa1C10S
CDB6LEa1C16S
CDB6LEa1C20S
CDB6LEa1C25S
CDB6LEa1C32S
CDB6LEa1C40S
CDB6LEa1C50S
CDB6LEa1C60S
CDB6LEa1D6S
CDB6LEa1D10S
CDB6LEa1D16S
CDB6LEa1D20S
CDB6LEa1D25S
CDB6LEa1D32S
CDB6LEa1D40S
CDB6LEa1D50S
CDB6LEa1D60S
2P
230
30
6
10
16
20
25
32
40
50
60
7
7
7
7
7
7
8
8
8
CDB6LEa2C6S
CDB6LEa2C10S
CDB6LEa2C16S
CDB6LEa2C20S
CDB6LEa2C25S
CDB6LEa2C32S
CDB6LEa2C40S
CDB6LEa2C50S
CDB6LEa2C60S
CDB6LEa2D6S
CDB6LEa2D10S
CDB6LEa2D16S
CDB6LEa2D20S
CDB6LEa2D25S
CDB6LEa2D32S
CDB6LEa2D40S
CDB6LEa2D50S
CDB6LEa2D60S
3P
400
30
6
10
16
20
25
32
40
50
60
10
10
10
10
10
10
12
12
12
CDB6LEa3C6S
CDB6LEa3C10S
CDB6LEa3C16S
CDB6LEa3C20S
CDB6LEa3C25S
CDB6LEa3C32S
CDB6LEa3C40S
CDB6LEa3C50S
CDB6LEa3C60S
CDB6LEa3D6S
CDB6LEa3D10S
CDB6LEa3D16S
CDB6LEa3D20S
CDB6LEa3D25S
CDB6LEa3D32S
CDB6LEa3D40S
CDB6LEa3D50S
CDB6LEa3D60S
3P+N
400
30
6
10
16
20
25
32
40
50
60
11
11
11
11
11
11
14
14
14
CDB6LEa6C6S
CDB6LEa6C10S
CDB6LEa6C16S
CDB6LEa6C20S
CDB6LEa6C25S
CDB6LEa6C32S
CDB6LEa6C40S
CDB6LEa6C50S
CDB6LEa6C60S
CDB6LEa6D6S
CDB6LEa6D10S
CDB6LEa6D16S
CDB6LEa6D20S
CDB6LEa6D25S
CDB6LEa6D32S
CDB6LEa6D40S
CDB6LEa6D50S
CDB6LEa6D60S
D curve
Note: 1. Width refers to multiple of 9 mm.
2. If the sensivitivity is 30mA,it's marked with "S" in the reference number.Aslo, 50mA is marked with
"W",100mA is marked with "Y",200mA is marked with "R",300mA is marked with "T".
20
CDB6LE Residual Current Operated Circuit Breaker
Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 3000A
Sensitivity: 30,50,100,200,300mA
Order Information
Voltage
(V)
Sensitivity
(mA)
Rating
(A)
Width
4P
400
30
6
10
16
20
25
32
40
50
60
13
13
13
13
13
13
16
16
16
Reference
C curve
D curve
CDB6LEa4C6S
CDB6LEa4C10S
CDB6LEa4C16S
CDB6LEa4C20S
CDB6LEa4C25S
CDB6LEa4C32S
CDB6LEa4C40S
CDB6LEa4C50S
CDB6LEa4C60S
CDB6LEa4D6S
CDB6LEa4D10S
CDB6LEa4D16S
CDB6LEa4D20S
CDB6LEa4D25S
CDB6LEa4D32S
CDB6LEa4D40S
CDB6LEa4D50S
CDB6LEa4D60S
Note: 1. Width refers to multiple of 9 mm.
2. If the sensivitivity is 30mA,it's marked with "S" in the reference number.Aslo, 50mA is marked with
"W",100mA is marked with "Y",200mA is marked with "R",300mA is marked with "T".
Technical Data
CDB6LE Residual Current Operated Circuit Breaker
RCBO
Electronic Type
IEC 61009-1
AC
Poles
1P+N,2P,3P,3P+N,4P
Rated Current In
6,10,16,20,25,32,40,50,60A
Standard
Electrical
Features
Rated Voltage Ue
230V AC for 1P+N/2P, 400V AC for 3P/3P+N/4P
Insulation Voltage Ui
500V
Breaking Capacity
3KA
Sensitivity
30,50,100,200,300mA
Tripping Curve(see following tripping curve pictures)
C curve:the magnetic release operates between 5 and 10
D curve:the magnetic release operates between 10 and 14
Mechanical
Features
Electrical Durability
2000 times
Mechanical Durability
2000 times
Protection Degree
2
Tropicalization
treatment 2
-5℃~+40℃
Ambient Temperature
6-32A,Up to 16mm cables, 40-60A,Up to 25mm2 cables
Screw
Rated Torque
Limiting Torque
Connection
2
Rate
current(A)
Installation
Mounting
Accessories
(Nm)
(Nm)
6-32
M4
2.0
3.0
40-60
M5
2.5
4.5
35mm Din-rail
OF
Contact Accessory:
Fault-indicating Accessory: SD
21
Final Distribution
Type
CDB6LE Residual Current Operated Circuit Breaker
Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 3000A
Sensitivity: 30,50,100,200,300mA
Tripping Curves
Final Distribution
Overall Dimensions
Accessories
SD
22
OF
CDB6LE
CDB6v Residual Current Protection Module
Standard: IEC 61009-1
Electronic type: AC
Sensitivity: 30,100,300mA
Function
CDB6v can be assembled with CDB6s to be residual current breaker overcurrent
Protection of persons against indirect contacting
Supplementary protection of persons against direct contacting
Prevention of electric-caused fire
Overvoltage protection by products marked "G"
Final Distribution
Order Information
Frame
Type
Voltage
(V)
Sensitivity
(mA)
Width
Reference
V32
1P+N
230
30
5
CDB6v321N
100
5
CDB6v321NR100
300
5
CDB6v321NR300
30
7
CDB6v322P
100
7
CDB6v322PR100
300
7
CDB6v322PR300
30
10
CDB6v323P
100
10
CDB6v323PR100
300
10
CDB6v323PR300
30
11
CDB6v323N
100
11
CDB6v323NR100
300
11
CDB6v323NR300
30
13
CDB6v324P
100
13
CDB6v324PR100
300
13
CDB6v324PR300
30
6
CDB6v631N
100
6
CDB6v631NR100
2P
400
3P
3P+N
4P
V63
1P+N
2P
230
400
3P
3P+N
4P
Note: Width refers to mutultiple of 9mm.
300
6
CDB6v631NR300
30
8
CDB6v632P
100
8
CDB6v632PR100
300
8
CDB6v632PR300
30
12
CDB6v633P
100
12
CDB6v633PR100
300
12
CDB6v633PR300
30
14
CDB6v633N
100
14
CDB6v633NR100
300
14
CDB6v633NR300
30
16
CDB6v634P
100
16
CDB6v634PR100
300
16
CDB6v634PR300
23
CDB6v Residual Current Protection Module
Standard: IEC 61009-1
Electronic type: AC
Sensitivity: 30,100,300mA
Technical Data
RCD
Final Distribution
Electrical
Features
Mechanical
Features
CDB6v Residual Current Protection Module
Standard
IEC61009-1
Electronic Type
AC
Poles
1P+N, 2P, 3P, 3P+N, 4P
Rated Current In
V32 In≤32A;V63 In≤63A
Rated Voltage Ue
230/400V AC
Rated Insulation Voltage
500V A
Breaking Capacity
after CDB6s assembled with
reference to CDB6s parameters
Sensitivity
30,100,300mA
Tripping Indication
On CDB6v is a residual opening
current indication, which distinguish
residual current from other faults
Manual Control
Manual control:allows for two kinds of reset
CDB6v resets at the same time with breaker
CDB6v resets before breaker
“G” products offer
overvoltage protection
280V±5% AC,applicable to
products with 1P+N and 2P
Electrical Durability
2000 times(In≤25A) 1000times(In>25A)
1000 times(In>25A)
Mechanical Durability
2000 times
Protection Degree
IP20
Tropicaliation
treatrment 2
Ambient Temperature
~
-5℃~+40℃
2
-Up to 16mm cables(V32)
2
-Up to 25mm cables(V63)
Connection
Installation
24
Rate
current(A)
Screw
Rated Torque
(Nm)
Limiting Torque
(Nm)
V32
V63
M4
M5
2.2
2.5
3.0
4.5
CDB6v Residual Current Protection Module
Standard: IEC 61009-1
Electronic type: AC
Sensitivity: 30,100,300mA
Overall Dimensions
Final Distribution
Pole
V32
V63
1P+N
45±0.32
54±0.37
2P
63±0.37
72±0.43
3P
90±0.5
108±0.57
3P+N
99±0.5
126±0.64
4P
117±0.57
144±0.72
Assembly
+
CDB6v can be assembled with CDB6s to be residual current breaker overcurrent
Protection of persons against indirect contacting
Supplementary protection of persons against direct contacting
Prevention of electric-caused fire
Overvoltage protection by products marked“G”
25
CDB2LE Residual Current Operated Circuit Breaker
Standard: IEC 60947-2
Electronic type: AC
Breaking Capacity: 10000A
Sensitivity: 30, 100, 300mA
Function
CDB2LE electronic type residual current operated circuit breakers combine the following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Protection of users against indirect contact
Protection of electrical installations against insulation faults (fire hazard, etc)
Isolation
Final Distribution
Order Information
Sensitivity Rating
(A)
(mA)
Reference
C curve
D curve
6
30
30
30
100
100
100
300
300
300
63
80
100
63
80
100
63
80
100
CDB2LEH1C63S
CDB2LEH1C80S
CDB2LEH1C100S
CDB2LEH1C63Y
CDB2LEH1C80Y
CDB2LEH1C100Y
CDB2LEH1C63T
CDB2LEH1C80T
CDB2LEH1C100T
CDB2LEH1D63S
CDB2LEH1D80S
CDB2LEH1D100S
CDB2LEH1D63Y
CDB2LEH1D80Y
CDB2LEH1D100Y
CDB2LEH1D63T
CDB2LEH1D80T
CDB2LEH1D100T
2P
9
30
30
30
100
100
100
300
300
300
63
80
100
63
80
100
63
80
100
CDB2LEH2C63S
CDB2LEH2C80S
CDB2LEH2C100S
CDB2LEH2C63Y
CDB2LEH2C80Y
CDB2LEH2C100Y
CDB2LEH2C63T
CDB2LEH2C80T
CDB2LEH2C100T
CDB2LEH2D63S
CDB2LEH2D80S
CDB2LEH2D100S
CDB2LEH2D63Y
CDB2LEH2D80Y
CDB2LEH2D100Y
CDB2LEH2D63T
CDB2LEH2D80T
CDB2LEH2D100T
3P
12
30
30
30
100
100
100
300
300
300
63
80
100
63
80
100
63
80
100
CDB2LEH3C63S
CDB2LEH3C80S
CDB2LEH3C100S
CDB2LEH3C63Y
CDB2LEH3C80Y
CDB2LEH3C100Y
CDB2LEH3C63T
CDB2LEH3C80T
CDB2LEH3C100T
CDB2LEH3D63S
CDB2LEH3D80S
CDB2LEH3D100S
CDB2LEH3D63Y
CDB2LEH3D80Y
CDB2LEH3D100Y
CDB2LEH3D63T
CDB2LEH3D80T
CDB2LEH3D100T
3P+N
12
30
30
30
100
100
100
300
300
300
63
80
100
63
80
100
63
80
100
CDB2LEH6C63S
CDB2LEH6C80S
CDB2LEH6C100S
CDB2LEH6C63Y
CDB2LEH6C80Y
CDB2LEH6C100Y
CDB2LEH6C63T
CDB2LEH6C80T
CDB2LEH6C100T
CDB2LEH6D63S
CDB2LEH6D80S
CDB2LEH6D100S
CDB2LEH6D63Y
CDB2LEH6D80Y
CDB2LEH6D100Y
CDB2LEH6D63T
CDB2LEH6D80T
CDB2LEH6D100T
Type
Width
1P+N
Note: Width refers to multiple of 9mm .
26
CDB2LE Residual Current Operated Circuit Breaker
Standard: IEC 60947-2
Electronic type: AC
Breaking Capacity: 10000A
Sensitivity: 30, 100, 300mA
Order Information
Type
Sensitivity Rating
(A)
(mA)
Width
4P
15
63
80
100
63
80
100
63
80
100
D curve
CDB2LEH4C63S
CDB2LEH4C80S
CDB2LEH4C100S
CDB2LEH4C63Y
CDB2LEH4C80Y
CDB2LEH4C100Y
CDB2LEH4C63T
CDB2LEH4C80T
CDB2LEH4C100T
CDB2LEH4D63S
CDB2LEH4D80S
CDB2LEH4D100S
CDB2LEH4D63Y
CDB2LEH4D80Y
CDB2LEH4D100Y
CDB2LEH4D63T
CDB2LEH4D80T
CDB2LEH4D100T
Note: Width refers to multiple of 9mm .
Technical Data
RCBO
Electrical
Features
CDB2LE Residual Current Operated Circuit Breake r
Standard
IEC60947-2
Electronic Type
AC
Poles
1P+N,2P,3P,3P+N,4P
Rated Current In
63,80,100A
Rated Voltage Ue
230V for 1P+N; 400V for 2P/3P/3P+N/4P
Insulation Voltage Ui
500V
Breaking Capacity
10KA
Sensitivity
30,100,300mA
Tripping Curve ( see following tripping curve pictures)
C curve:the magnetic release operated between 5 and 10 In
D curve:the magnetic release operated between 10 and 14 In
Mechanical
Features
Electrical Durability
1500 times
Mechanical Durability
8500 times
Protection Degree
2
Tropicalization
treatment 2
Ambient Temperature
-5℃~+40℃
Connection
Installation
Accessories
Up to 50mm2 cables
Rate
current(A)
Screw
Rated Torque
(Nm)
Limiting Torque
(Nm)
63-100
M7
4
5.5
Contact Accessory:
OF
Shunt -trip Release:
MX+OF
27
Final Distribution
30
30
30
100
100
100
300
300
300
Reference
C curve
CDB2LE Residual Current Operated Circuit Breaker
Standard: IEC 60947-2
Electronic type: AC
Breaking Capacity: 10000A
Sensitivity: 30, 100, 300mA
Tripping Curve
e
Final Distribution
Overall Dimensions
Accessories
MX+OF
28
OF
CDB2LE
CDB3LE Residual Current Operated Circuit Breaker
Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 4500A
Sensitivity: 30mA
Function
Order Information
Type
Width
(mm)
Rating(A)
1P+N
36
6
10
16
20
25
32
40
Reference
C curve
CDB3LEL5C6S
CDB3LEL5C10S
CDB3LEL5C16S
CDB3LEL5C20S
CDB3LEL5C25S
CDB3LEL5C32S
CDB3LEL5C40S
Technical Data
CDB3LE Residual Current Operated Circuit Breaker
RCBO
Electrical
Features
Standard
IEC61009-1
Electronic Type
AC
Poles
1P+N
Rated Current In
6,10,16,20,25,32,40A
Rated Voltage Ue
230V AC
Insulation Voltage Ui
500V
Breaking Capacity
4.5KA
Sensitivity
30mA
Tripping Curve (see following tripping curve pictures)
C curve:the magnetic release operates between 5 and 10 In
Mechanical
Features
Electrical Durability
2000 times
Mechanical Durability
2000 times
Protection Degree
2
Tropicalization
treatment 2
Ambient Temperature
-5℃~+40℃
2
Connection
Installation
Mounting
Up to 16mm cables
Rate
current(A)
Screw
Rated Torque
(Nm)
Limiting Torque
(Nm)
6-40
M5
2.5
4.5
35mm Din-rail
29
Final Distribution
CDB3LE electronic type residual current operated circuit breakers combine the following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Protection of users against indirect contact
Additional protection for users against direct contacts (30mA)
Protection of electrical installations against insulation faults (fire hazard, etc)
Isolation
CDB3LE Residual Current Operated Circuit Breaker
Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 4500A
Sensitivity: 30mA
Tripping Curve
Final Distribution
Overall Dimensions
30
CDL7 Electromagnetic Type
Residual Current Switch
Standard: IEC 61008
RCCB Type: A , AC
Sensitivity: 10, 30, 100, 300mA
Function
CDL7 electromagnetic type residual current switch combine the following functions:
Protection for users against indirect contact
Additional protection for users against direct contacts (30mA)
Protection for electrical installations against insulation faults (fire hazard, etc)
Order Information
4
10
16
25
40
63
80
100
4P
8
10
16
25
40
63
80
100
10
30
100
300
10
30
100
300
10
30
100
300
30
100
300
30
100
300
30
100
300
30
100
300
CDL7210LA
CDL7210SA
CDL7210YA
CDL7210TA
CDL7216LA
CDL7216SA
CDL7216YA
CDL7216TA
CDL7225LA
CDL7225SA
CDL7225YA
CDL7225TA
CDL7240SA
CDL7240YA
CDL7240TA
CDL7263SA
CDL7263YA
CDL7263TA
CDL7280SA
CDL7280YA
CDL7280TA
CDL72100SA
CDL72100YA
CDL72100TA
CDL7210LC
CDL7210SC
CDL7210YC
CDL7210TC
CDL7216LC
CDL7216SC
CDL7216YC
CDL7216TC
CDL7225LC
CDL7225SC
CDL7225YC
CDL7225TC
CDL7240SC
CDL7240YC
CDL7240TC
CDL7263SC
CDL7263YC
CDL7263TC
CDL7280SC
CDL7280YC
CDL7280TC
CDL72100SC
CDL72100YC
CDL72100TC
10
30
100
300
10
30
100
300
10
30
100
300
30
100
300
30
100
300
30
100
300
30
100
300
CDL7410LA
CDL7410SA
CDL7410YA
CDL7410TA
CDL7416LA
CDL7416SA
CDL7416YA
CDL7416TA
CDL7425LA
CDL7425SA
CDL7425YA
CDL7425TA
CDL7440SA
CDL7440YA
CDL7440TA
CDL7463SA
CDL7463YA
CDL7463TA
CDL7480SA
CDL7480YA
CDL7480TA
CDL74100SA
CDL74100YA
CDL74100TA
CDL7410LC
CDL7410SC
CDL7410YC
CDL7410TC
CDL7416LC
CDL7416SC
CDL7416YC
CDL7416TC
CDL7425LC
CDL7425SC
CDL7425YC
CDL7425TC
CDL7440SC
CDL7440YC
CDL7440TC
CDL7463SC
CDL7463YC
CDL7463TC
CDL7480SC
CDL7480YC
CDL7480TC
CDL74100SC
CDL74100YC
CDL74100TC
Final Distribution
2P
31
CDL7 Electromagnetic Type
Residual Current Switch
Standard: IEC 61008
RCCB Type: A , AC
Sensitivity: 10, 30, 100, 300mA
Technical Data
RCCB
Final Distribution
Electrical
Features
Mechanical
Features
Connection
CDL7 Electromagnetic Type Residual Current Switc h
Standard
IEC61008
Certification
,
KEMA、CB
Type
AC, A
Poles
2P、4P
,
Rated Current In
A
10,16,25,40,63,80,100P
Rated Voltage Ue
230/400V AC
Insulation Voltage Ui
500V
Sensitivity
10,30,100,300mA
Electrical Durability
1000 times
Mechanical Durability
2000 times
Overload or Short
Circuit Protection
no
Tripping Indication
Instantaneous, rated residual
operated current unadjustable
Fault Curren Indicator
Mechanical indication in the front
Protection Degree
2
Tropicalization
Treatment 2
Ambient Temperature
-25℃~+40℃
2
Rate
Installation
Screw
current(A)
25-100
Mounting
Power source
Auxilary
Overall Dimensions
32
2
Up to 35mm cables(In>63A)
Up to 16mm
M5
Rated Torque
Limiting Torque
(Nm)
(Nm)
2.0
4.5
35mm Din-rail
Not need
Accessory
CDB6,CDB6LE
The sketch map of installation with breakers
Final Distribution
SD
OF
Breaker
MX+OF
Remote Control Auxiliaries
OF contact auxiliary
SD fault-indicating switch
Indicate ON or OFF state of the breaker
Sent out fault signal on the font when breaking down
Basic type of auxiliary contact:1NO+1NC
Indicator on the front to show fault trip
2
Connection: 1-4mm cables
Basic type of auxiliary contact:1NO+1NC
Connection: 1-4mm2 cables
Tripping Device
Introductions
MX+OF shunt trip release
OF, SD must be assembled on the left ,one auxiliary only
Indicate ON or OFF state of the breaker
Each time only one auxiliary accepted in the left of MCB
Make the assembled breaker trip once got signal
MX+OF must be assembled on the right, one MX+OF only
Basic type of auxiliary contact:1NO+1NC
CDB6LE can't assemble MX+OF
Connection: 1-4mm2 cables
Order Information
type
Width(mm) Voltage(V)
Reference
OF
9
CDB6OF
SD
9
CDB6SD
MX+OF
18
AC/DC 12V
CDB6MX12
18
AC/DC 24V
CDB6MX24
18
AC/DC 48V
CDB6MX48
18
AC 110-130V
CDB6MX110
18
AC 130V
CDB6MX130
18
AC 230V
CDB6MX230
18
AC 400V
CDB6MX400
33
Accessory
CDB6s
The sketch map of installation with breakers
Final Distribution
SD
CDB6s
OF
MX+OF
Remote Control Auxiliaries
OF contact auxiliary
SD fault-indicating switch
Indicate ON or OFF state of the breaker
Sent out fault signal when breaking down
Basic type of auxiliary contact:1NO+1NC
Indicator on the front to show fault trip
Connection:1-4mm2 cables
Basic type of auxiliary contact:1NO+1NC
Connection:1-4mm2 cables
Tripping Device
Introductions
MX+OF shunt trip release
OF,SD must be assembled on the left ,one auxiliary only
Indicate ON or OFF state of the breaker
Each time only one auxiliary accepted in the left of MCB
Make the assembled breaker trip while given signal
MX+OF must be assembled on the right, one MX+OF only
Basic type of auxiliary contact:1NO+1NC
CDB6s can't assemble MX+OF while assembled with CDB6v
Connection:1-4mm2 cables
Order Information
34
type
Width(mm) Voltage(V)
Reference
OF
9
CDB6sOF
SD
9
CDB6sSD
MX+OF
118
AC/DC12-24V
CDB6sMX24
18
AC/DC24-48V
CDB6sMX48
18
AC110-127V
CDB6sMX110
18
AC230-400V
CDB6sMX230
Accessory
CDB2,CDB2LE
The sketch map of installation with breakers
Final Distribution
MX+OF
Remote Control Auxiliaries
OF contact auxiliary
Indicate ON or OFF state of the breaker
Basic type of auxiliary contact:2NO+2NC
OF
Breaker
Introductions
MX+OF, OF must be assembled on the left
Each time only one auxiliary accepted in the left of MCB
Connection: 1-4mm2 cables
Tripping Device
MX+OF shunt trip release
Indicate ON or OFF state of the breaker
Make the assembled breaker trip once got signal
Basic type of auxiliary contact:1NO+1NC
Connection: 1-4mm2 cables
Order Information
Type
Width(mm) Description
Reference
OF
18
1NO 1NC
CDB2OF11
18
2NO 2NC
CDB2OF22
18
AC/DC24V
CDB2MX24
18
AC48V~130V DC48V
CDB2MX48
18
AC230V-400V DC110V-130V CDB2MX230
MX+OF
35
Accessory
Busbar
Technical Data
Final Distribution
Standard
IEC 60664
Material of busbar
E-CU-F25
Material of insulation
PVC
Short-circuit strength
50kA
Nominal voltage
415V
Operating voltage
Max 500V
Surge voltage
4kV
Clima stability
IEC 60068-2
Order Information
Type
Thickness Section Max.
Pole of pin
cross current(A)
(mm)
(mm2) End feed-in
PIN-TYPE 1
2
3
4
U-TYPE
1
2
3
4
36
1.2
1.5
1.5
1.5
1.2
1.5
1.5
1.5
1.2
1.5
1.5
1.5
1.2
1.5
1.5
1.5
1.2
1.5
1.5
1.5
1.2
1.5
1.5
1.5
1.2
1.5
1.5
1.5
1.2
1.5
1.5
1.5
6
10
13
16
6
10
13
16
6
10
13
16
6
10
13
16
6
10
13
16
6
10
13
16
6
10
13
16
6
10
13
16
40
63
70
80
40
63
70
80
40
63
70
80
40
63
70
80
40
63
70
80
40
63
70
80
40
63
70
80
40
63
70
80
A
Reference
5
7
9
11
5
7
9
11
5
7
9
11
5
7
9
11
5
7
9
11
5
7
9
11
5
7
9
11
5
7
9
11
CBB14012P
CBB16315P
CBB17015P
CBB18015P
CBB24012P
CBB26315P
CBB27015P
CBB28015P
CBB34012P
CBB36315P
CBB37015P
CBB38015P
CBB44012P
CBB46315P
CBB47015P
CBB48015P
CBB14012F
CBB16315F
CBB17015F
CBB18015F
CBB24012F
CBB26315F
CBB27015F
CBB28015F
CBB34012F
CBB36315F
CBB37015F
CBB38015F
CBB44012F
CBB46315F
CBB47015F
CBB48015F
Dimension(mm)
A
A
A
A
A
A
A
A
CDCH8 Modular Contactor
Standard: IEC 61095
Function
CDCH8 Modular Contactor provide:
Automatic control on equipment in buildings
Switch on or Swith off lighting or other equipments
Order Information
Current (A)
Voltage (V)
Reference
2P
20
220V
230V
220V
230V
CDCH8202M
CDCH8202N
CDCH8252M
CDCH8252N
25
Final Distribution
Pole
Technical Data
Building Control Command Devices
CDCH8 Modular Contactor
IEC 61095
Standard
KEMA CE CB
Certification
Type
AC-7a
AC-7b
230V AC
Rated Voltage Ue
500V AC
Rated Insulation Voltage Ui
Conventional Thermal Current(I )
Rated Current(le)
Rated power
Operation Frequency
20A/25A
20A/25A
9A/10A
4kw/5.4kw
1.2kw/1.4kw
1200times/h
30times/h
≥30000times
Operation Time
Making&Breaking capacity
1.5le
8le
AC-7b,8le,10S
With stand Overcurrent Capacity
Adapted to fuse :RT18-32X/32
Short-circuit Protection
Ambient Temperature
Connection
Adapted to breaker :CDB6s-63/C32
-5℃~+40℃
~
Both 1 and 2 lines can be used
CDCH8-20 1~2.5mm2, CDCH8-25,1~4mm2
Techenical Data of Coil
Coil Voltage(Us)
220/230V AC
Allowable Voltage of
Controlloop(V)
Operating:85%~110%Us
Release:20%~75%Us
Rated Power of Coil
Start:16VA
Holding:4VA
Working power:1.4W
37
CDCH8 Modular Contactor
Standard: IEC 61095
Wiring Diagram
Final Distribution
Overall Dimensions
38
CDRT8 Time Relay
Standard:IEC 60947.5
Function
CDRT8 Time Relay provide:
Disconnect Delay
Connect Delay
Order Information
Delay type
Reference
10
power delay
CDRT810B
120
power delay
CDRT8120B
480
power delay
CDRT8480B
480
off delay
CDRT8480A
Final Distribution
Limit delay time
Technical Data
Building Control Command Devices
CDRT8 Time Relay
Standard
IEC 60947.5
Rated Voltage Ue
230V AC
Rated Current(le)
5A
Delay Type
Off dalay
Power delay
10s 120s 480s
Limit Delay Time
th
Conventional Thermal Current(l )
8A
Timing Range
Contact Type
Normally open contact
Contact Number
1
Rated Control Supply Voltage(Us)
230V AC
Operating Voltage Range
85%-110%Us
Electrical Durability
30000 times
Rated Wattage
<1W
Insulation Resistance
>
To each:AC 1760V 5s
Insulation Strength
Disconnect between the
contact position:AC 1000V 1min
Connection
up to 1mm2 cables
39
CDRT8 Time Relay
Standard:IEC 60947.5
Wiring Diagram
Final Distribution
Overall Dimensions
19max
68max
40
CDY1 Surge Protective Devices
Standard:
IEC61643
Function
CDY1 surge protective devices provide:
Applicable to household appliances and the like to offer protection
When there is an over-voltage caused by either lightning strike or operation in the
circuit
Imax
(kA)
Imax
Imax
(kA)
(kA)
20
40
60
80
100
Uc
(V)
Uc
Uc
(V)
(V)
Up
(kV)
Up
Up
(kV)
(kV)
Final Distribution
Order Information
Reference
1P
Reference
Reference
1P
1P
2P
3P
4P
1P+N
3P+N
2P
2P
3P
3P
4P
4P
1P+N
1P+N
3P+N
275
1.3
CDY1201275
CDY1202275
CDY1203275
CDY1204275
CDY1205275
CDY1206275
385
1.5
CDY1201385
CDY1202385
CDY1203385
CDY1204385
CDY1205385
CDY1206385
420
1.8
CDY1201420
CDY1202420
CDY1203420
CDY1204420
CDY1205420
CDY1206420
275
1.5
CDY1401275
CDY1402275
CDY1403275
CDY1404275
CDY1405275
CDY1406275
385
1.8
CDY1401385
CDY1402385
CDY1403385
CDY1404385
CDY1405385
CDY1406385
420
2.0
CDY1401420
CDY1402420
CDY1403420
CDY1404420
CDY1405420
CDY1406420
275
1.8
CDY1601275
CDY1602275
CDY1603275
CDY1604275
CDY1605275
CDY1606275
385
2.2
CDY1601385
CDY1602385
CDY1603385
CDY1604385
CDY1605385
CDY1606385
420
2.5
CDY1601420
CDY1602420
CDY1603420
CDY1604420
CDY1605420
CDY1606420
275
2.0
CDY1801275
CDY1802275
CDY1803275
CDY1804275
CDY1805275
CDY1806275
385
2.2
CDY1801385
CDY1802385
CDY1803385
CDY1804385
CDY1805385
CDY1806385
420
2.5
CDY1801420
CDY1802420
CDY1803420
CDY1804420
CDY1805420
CDY1806420
275
2.2
CDY11001275
CDY11002275
CDY11003275
CDY11004275
CDY11005275
CDY11006275
385
2.5
CDY11001385
CDY11002385
CDY11003385
CDY11004385
CDY11005385
CDY11006385
420
2.5
CDY11001420
CDY11002420
CDY11003420
CDY11004420
CDY11005420
CDY11006420
41
CDY1 Surge Protective Devices
Standard:
IEC61643
Technical Data
Final Distribution
Type
Pole
Nominal discharge
current In(8/20us) kA
Maximum discharge current
Imax(8/20us) kA
Maximum continuous
operational voltage Uc V
Protection level Up kV
Leakage current
(75%Uc 1mA) uA
Response time ns
Standard: IEC 61643
Certification: SEMKO, CB
Overall Dimensions
42
CDY1-80
CDY1-100
1P, 1P+N, 2P, 3P, 3P+N, 4P
10
20
30
CDY1-20
CDY1-40
40
50
20
80
100
40
CDY1-60
60
275 385 420 275 385 420 275 385 420 275 385 420 275 385 420
1.3
≤20
≤25
1.5
1.8 1.5 1.8 2.0 1.8 2.2 2.5 2.0 2.2 2.5 2.2 2.5 2.5
CDPZ50 Series Lighting Distribution Box
Standard: IEC60439-1 IEC60670
Function
CDPZ50 series lighting distribution box provide:
Protection against overload
Protection against over voltage
Protection against leakage
Material
Holistic steel-plastic
Installation
Surface installation
Flush installation
Material
Full plastic
(fire-retardancy)
Installation
Surface installation
Flush installation
Full plastic
(Non fire-retardancy)
Surface installation
Flush installation
No. of loop
6
Final Distribution
Order Information
Reference
CDPZ50M6
8
CDPZ50M8
12
CDPZ50M12
16
CDPZ50M16
20
CDPZ50M20
24
6
CDPZ50M24
CDPZ50R6
8
CDPZ50R8
12
CDPZ50R12
16
CDPZ50R16
20
CDPZ50R20
24
No. of loop
4
6
8
12
15
18
24
36
4
6
8
12
15
18
24
36
4
6
8
12
15
18
24
36
4
6
8
12
15
18
24
36
CDPZ50R24
Reference
CDPZ50PM4IP30F
CDPZ50PM6IP30F
CDPZ50PM8IP30F
CDPZ50PM12IP30F
CDPZ50PM15IP30F
CDPZ50PM18IP30F
CDPZ50PM24IP30F
CDPZ50PM36IP30F
CDPZ50PR4IP30F
CDPZ50PR6IP30F
CDPZ50PR8IP30F
CDPZ50PR12IP30F
CDPZ50PR15IP30F
CDPZ50PR18IP30F
CDPZ50PR24IP30F
CDPZ50PR36IP30F
CDPZ50PM4IP30NF
CDPZ50PM6IP30NF
CDPZ50PM8IP30NF
CDPZ50PM12IP30NF
CDPZ50PM15IP30NF
CDPZ50PM18IP30NF
CDPZ50PM24IP30NF
CDPZ50PM36IP30NF
CDPZ50PR4IP30NF
CDPZ50PR6IP30NF
CDPZ50PR8IP30NF
CDPZ50PR12IP30NF
CDPZ50PR15IP30NF
CDPZ50PR18IP30NF
CDPZ50PR24IP30NF
CDPZ50PR36IP30NF
43
CDPZ50 Series Lighting Distribution Box
Standard: IEC60439-1 IEC60670
Technical Data
Final Distribution
Type
CDPZ50
CDPZ50P
Material
Box:Metal, Cover:Plastic
Full Plastic
Fire-resistancy
Fire-resistancy
Optional
Protection grade
IP30
Rated operation voltage
230/400V
Rated insulated voltage
500V
Rated operating current
100A
Withstand current
6kA
Overall Dimensions
Unit:mm
Surface installation
Flush installation
CDPZ50
Holistic steel-plastic
Surface installation
Flush installation
Thickness
Loop number
6
8
12
16
20
24
A
171
207
279
351
423
303
A
163
199
272
343
413
282
C
90
90
90
90
90
90
B
220
220
220
220
220
383
B
200
200
200
200
200
364
CDPZ50P
Full plastic
Loop number
4
6
8
12
15
18
24
36
44
Surface installation
A
110
147
183
255
310
362
270
270
B
200
200
200
200
200
218
324
459
Flush installation
Thickness
A
126
162
198
270
324
378
261
261
C
90
90
90
90
90
90
90
90
B
200
200
200
200
200
216
310
441
JXF Power Distribution Box
Standard: EN60529
Function
JXF power distribution box provide:
Control, monitering, measurement and protection for the electric power loops and
main power controlling equipment.
Order Information
Overall
Installation
Mounting plate
Final Distribution
(mm)
Lock
Thick
JXF-2520/14 IP43
JXF-3025/14 IP43
JXF-3025/18 IP43
JXF-3030/14 IP43
JXF-3030/18 IP43
JXF-4030/14 IP43
JXF-4030/20 IP43
JXF-5040/14 IP43
JXF-5040/20 IP43
JXF-5040/25 IP43
JXF-6040/14 IP43
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 250
300
300
300
300
400
400
500
500
500
600
200
250
250
300
300
300
300
400
400
400
400
140
140
180
140
180
140
200
140
200
250
140
290
340
340
340
340
440
440
540
540
540
150
200
200
250
250
250
250
350
350
350
170
220
220
220
220
320
320
420
420
420
158
208
208
258
258
258
258
358
358
358
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1
1
1
1
1
1
1
1
2
2
JXF252014
JXF302514
JXF302518
JXF303014
JXF303018
JXF403014
JXF403020
JXF504014
JXF504020
JXF504025
JXF-6040/20 IP43
JXF-6040/25 IP43
JXF-6050/14 IP43
JXF-6050/20 IP43
JXF-6050/25 IP43
JXF-7050/16 IP43
JXF-7050/20 IP43
JXF-7050/25 IP43
JXF-8060/20 IP43
JXF-8060/25 IP43
JXF-10080/20 IP43
JXF-10080/25 IP43
JXF-10080/30 IP43
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 1.5 600
600
600
600
600
700
700
700
800
800
1000
1000
1000
400
400
500
500
500
500
500
500
600
600
800
800
800
200
250
140
200
250
160
200
250
200
250
200
250
300
640
640
640
640
640
640
740
740
740
840
840
1040
1040
1040
350
350
350
450
450
450
450
450
450
550
550
750
750
750
520
520
520
520
520
520
620
620
620
720
720
920
920
920
358
358
358
458
458
458
458
458
458
558
558
758
758
758
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.5
1.5
1.5
2
2
2
2
2
2
2
2
2
2
2
2
JXF604014
JXF604020
JXF604025
JXF605014
JXF605020
JXF605025
JXF705016
JXF705020
JXF705025
JXF806020
JXF806025
JXF1008020
1.5
1.5
2
2
JXF1008025
JXF1008030
JXF-2520/14 IP43 Improved
JXF-3025/14 IP43 Improved
JXF-3025/18 IP43 Improved
JXF-3030/14 IP43 Improved
JXF-3030/18 IP43 Improved
JXF-4030/14 IP43 Improved
JXF-4030/20 IP43 Improved
JXF-5040/14 IP43 Improved
JXF-5040/20 IP43 Improved
JXF-5040/25 IP43 Improved
JXF-6040/14 IP43 Improved
JXF-6040/20 IP43 Improved
JXF-6040/25 IP43 Improved
JXF-6050/14 IP43 Improved
JXF-6050/20 IP43 Improved
JXF-6050/25 IP43 Improved
JXF-7050/16 IP43 Improved
JXF-7050/20 IP43 Improved
JXF-7050/25 IP43 Improved
JXF-8060/20 IP43 Improved
JXF-8060/25 IP43 Improved
JXF-10080/20 IP43 Improved
JXF-10080/25 IP43 Improved
JXF-10080/30 IP43 Improved
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 1.5 250
300
300
300
300
400
400
500
500
500
600
600
600
600
600
600
700
700
700
800
800
1000
1000
1000
200
250
250
300
300
300
300
400
400
400
400
400
400
500
500
500
500
500
500
600
600
800
800
800
140
140
180
140
180
140
200
140
200
250
140
200
250
140
200
250
160
200
250
200
250
200
250
300
290
340
340
340
340
440
440
540
540
540
640
640
640
640
640
640
740
740
740
840
840
1040
1040
1040
150
200
200
250
250
250
250
350
350
350
350
350
350
450
450
450
450
450
450
550
550
750
750
750
170
220
220
220
220
320
320
420
420
420
520
520
520
520
520
520
620
620
620
720
720
920
920
920
158
208
208
258
258
258
258
358
358
358
358
358
358
458
458
458
458
458
458
558
558
758
758
758
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.5
1.5
1.5
1.5
1.5
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
JXF252014B
JXF302514B
JXF302518B
JXF303014B
JXF303018B
JXF403014B
JXF403020B
JXF504014B
JXF504020B
JXF504025B
JXF604014B
JXF604020B
JXF604025B
JXF605014B
JXF605020B
JXF605025B
JXF705016B
JXF705020B
JXF705025B
JXF806020B
JXF806025B
JXF1008020B
JXF1008025B
JXF1008030B
45
JXF Power Distribution Box
Standard: EN60529
Order Information
Dimension(mm)
Overall
(mm)
Installation
Mounting plate
Lock
Thick
Final Distribution
JXF-2520/14 IP54 JXF-3025/14 IP54 JXF-3025/18 IP54 JXF-3030/14 IP54 JXF-3030/18 IP54 JXF-4030/14 IP54 JXF-4030/20 IP54 JXF-5040/14 IP54 JXF-5040/20 IP54 JXF-5040/25 IP54 JXF-6040/14 IP54 JXF-6040/20 IP54 JXF-6040/25 IP54 JXF-6050/14 IP54 JXF-6050/20 IP54 JXF-6050/25 IP54 JXF-7050/16 IP54 JXF-7050/20 IP54 JXF-7050/25 IP54 JXF-8060/20 IP54 JXF-8060/25 IP54 JXF-10080/20 IP54 JXF-10080/25 IP54 JXF-10080/30 IP54 46
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 250
300
300 300
300
400
400
500
500
500
600
600
600
600
600
600
700
700
700
800
800
1000
1000
1000
200
250
250
300
300
300
300
400
400
400
400
400
400
500
500
500
500
500
500
600
600
800
800
800
140
140
180
140
180
140
200
140
200
250
140
200
250
140
200
250
160
200
250
200
250
200
250
300
320
370
370
370
370
470
470
570
570
570
670
670
670
670
670
670
770
770
770
870
870
1070
1070
1070
150
200
200
250
250
250
250
350
350
350
350
350
350
450
450
450
450
450
450
550
550
750
750
750
215
265
265
265
265
365
365
465
465
465
565
565
565
565
565
565
665
665
665
765
765
965
965
965
148
198
198
248
248
248
248
348
348
348
348
348
348
448
448
448
448
448
448
548
548
748
748
748
2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1
1
1
1
1
1
1
2
2
JXF252014Q
JXF302514Q
JXF302518Q
JXF303014Q
JXF303018Q
JXF403014Q
JXF403020Q
JXF504014Q
JXF504020Q
2
2
2
2
2
2
2
2
2
2
JXF504025Q
JXF604014Q
JXF604020Q
JXF604025Q
JXF605014Q
JXF605020Q
JXF605025Q
JXF705016Q
JXF705020Q
JXF705025Q
2
2
2
2
2
JXF806020Q
JXF806025Q
JXF1008020Q
JXF1008025Q
JXF1008030Q
JXF Power Distribution Box
Standard: EN60529
Technical Data
JXF IP43
JXF IP43 Improved
JXF IP54
Protection grade
IP43
IP43
IP54
Standard:
EN60529
Certificate
CE
Rated voltage
220/400V
Rated insulated voltage
660V
Rated operating current
400A
Withstand current
15kA
Sheet thickness
1.0~1.5mm
1.0~1.5mm
1.2~1.5mm
Mounting plate thickness 1.0~1.5mm
1.0~1.5mm
2.0mm
Hinge
Normal
Enhanced
Enhanced
Sealing rubber gasket
Seal band
Black rubber gasket
Black rubber gasket
Cable gland
Top and bottom
bottom only
bottom only
Final Distribution
Type
Overall Dimensions
Unit: mm
sealing rubber gasket
sealing rubber
gasket
handle lock
door
wall fixing bracket
box
hinge
47
Contents
Low-voltage Distribution
Low-voltage
Distribution
48
Molded Case Circuit Breaker
49-63
CDM1
Molded Case Circuit Breaker
49
CDMLE
Earth-Leakage Circuit Breaker
57
Air Circuit Breaker
64-82
CDW7
64
Air Circuit Breaker
CDM1 Moulded Case Circuit Breaker
Standard: IEC 60947-2
Function
CDM1 moulded case circuit breaker provide:
To distribute electric power
To protect power line and equipments against overload, undervoltage and shortcircuit faults (In≤400A)
To infrequently start and control AC motors
Order Information
Type
CDM1-63
In A
3P
2P
3P
4P
49
Low-voltage
CDM1-100
40
50
63
10
16
20
25
32
40
50
63
16
20
25
32
40
50
63
80
100
16
20
25
32
40
50
63
80
100
16
20
25
32
40
50
63
80
100
Type L
CDM163L103
CDM163L163
CDM163L203
CDM163L253
CDM163L323
CDM163L403
CDM163L503
CDM163L633
-----------------CDM1100L163
CDM1100L203
CDM1100L253
CDM1100L323
CDM1100L403
CDM1100L503
CDM1100L633
CDM1100L803
CDM1100L1003
----------
Distribution
4P
10
16
20
25
32
Reference
Type M
CDM163M103
CDM163M163
CDM163M203
CDM163M253
CDM163M323
CDM163M403
CDM163M503
CDM163M633
CDM163M104
CDM163M164
CDM163M204
CDM163M254
CDM163M324
CDM163M404
CDM163M504
CDM163M634
CDM1100M162
CDM1100M202
CDM1100M252
CDM1100M322
CDM1100M402
CDM1100M502
CDM1100M632
CDM1100M802
CDM1100M1002
CDM1100M163
CDM1100M203
CDM1100M253
CDM1100M323
CDM1100M403
CDM1100M503
CDM1100M633
CDM1100M803
CDM1100M1003
CDM1100M164
CDM1100M204
CDM1100M254
CDM1100M324
CDM1100M404
CDM1100M504
CDM1100M634
CDM1100M804
CDM1100M1004
CDM1 Moulded Case Circuit Breaker
Standard: IEC 60947-2
Order Information
Type
CDM1-225
In A
2P
3P
Low-voltage
Distribution
4P
CDM1-400
3P
4P
CDM1-630
3P
4P
CDM1-800
3P
4P
CDM1-1250 3P
100
125
160
180
200
225
100
125
160
180
200
225
100
125
160
180
200
225
200
225
250
315
350
400
200
215
250
315
350
400
400
500
630
400
500
630
400
500
630
700
800
400
500
630
700
800
700
800
1000
1250
Reference
Type L
Type M
CDM1225M1002 -CDM1225M1252 -CDM1225M1602 -CDM1225M1802 --CDM1225M2002
-CDM1225M2252
CDM1225L1003
CDM1225M1003
CDM1225L1253
CDM1225M1253
CDM1225L1603
CDM1225M1603
CDM1225L1803
CDM1225M1803
CDM1225L2003
CDM1225M2003
CDM1225L2253
CDM1225M2253
-CDM1225M1004
-CDM1225M1254
-CDM1225M1604
-CDM1225M1804
-CDM1225M2004
-CDM1225M2254
CDM1400L2003
CDM1400M2003
CDM1400L2253
CDM1400M2253
CDM1400L2503
CDM1400M2503
CDM1400L3153
CDM1400M3153
CDM1400L3503
CDM1400M3503
CDM1400L4003
CDM1400M4003
CDM1400M2004 -CDM1400M2254 -CDM1400M2504 --CDM1400M3154
-CDM1400M3504
-CDM1400M4004
CDM1630L4003
CDM1630M4003
CDM1630L5003
CDM1630M5003
CDM1630L6303
CDM1630M6303
-CDM1630M4004
-CDM1630M5004
-CDM1630M6304
CDM1800L4003
CDM1800M4003
CDM1800L5003
CDM1800M5003
CDM1800L6303
CDM1800M6303
CDM1800L7003
CDM1800M7003
CDM1800L8003
CDM1800M8003
-CDM1800M4004
-CDM1800M5004
-CDM1800M6304
-CDM1800M7004
-CDM1800M8004
-CDM11250M7003
-CDM11250M8003
-CDM11250M10003
-CDM11250M12503
Note: The connection mode for CDM1 is the fixed type front connection.
50
CDM1 Moulded Case Circuit Breaker
Standard: IEC 60947-2
Order Information for Assessories
Voltage (V) Type
230V AC
400V AC
CDM1-63
CDM1-100
CDM1-225
CDM1-400
CDM1-630
OF
CDM163OF*
SD
CDM163SD*
TR(Round Handle) TS(Square Handle)
CDM163TR
CDM163TS
CDM1100OF* CDM1100SD* CDM1100TR
CDM1100TS
CDM1225OF* CDM1225SD* CDM1225TR
CDM1225TS
CDM1400OF* CDM1400SD* CDM1400TR
CDM1400TS
CDM1630OF* CDM1630SD* CDM1630TR
CDM1630TS
CDM1800OF* CDM1800SD* CDM1800TR
CDM1800TS
CDM11250OF*
Note 1: MN and MX could be sold with CDM1 product and installed by manufactory
2: *means the connecting type;
Blank: terminal connection;
D5: 500mm wire connection
9
8
10
7
11
1
2
12
6
5
4
13
3
1
Connection
6
Shunt release contactor
11
Stationary
type rear connection
R
2
Phase partition
7
Undervoltage release contactor
12
Alarm contactor
3
Motor mechanism
8
Plug-type connection terminal
13
Auxiliary contactor
4
Round handle mechanism
9
Plug-type front connection
5
Quadrate handle mechanism
10
Plug-type rear connection
51
Low-voltage
CDM1-1250
MX
CDM163MX230*
CDM163MX400*
CDM1100MX230*
CDM1100MX400*
CDM1225MX230*
CDM1225MX400*
CDM1400MX230*
CDM1400MX400*
CDM1630MX230*
CDM1630MX400*
CDM1800MX230*
CDM1800MX400*
CDM11250MX230*
CDM11250MX400*
Distribution
CDM1-800
Reference
MN
CDM163MN230*
CDM163MN400*
CDM1100MN230*
CDM1100MN400*
CDM1225MN230*
CDM1225MN400*
CDM1400MN230*
CDM1400MN400*
CDM1630MN230*
CDM1630MN400*
CDM1800MN230*
CDM1800MN400*
CDM11250MN230*
CDM11250MN400*
CDM1 Moulded Case Circuit Breaker
Standard: IEC 60947-2
Technical Data
Main technical parameters are shown in the table below
MCCB
CDM1
standard
IEC 60947-2
MCCB
KEMA,SEMKO,CB,CE
Type
CDM1-63 CDM1-100 CDM1-225 CDM1-400 CDM1-630 CDM1-800 CDM1-1250
63
100
225
400
630
800
1250
Frame size rated
current A
Number of poles
Rated frequency Hz
Rated current In A
Low-voltage
Distribution
Rated insulation
voltage Ui V
Rated impulse
withstand
voltage Uimp V
Rated operational
voltage Ue V
Icu kA Type M
(400V) Type L
Ics kA Type M
(400V) Type L
3P,4P
50/60
10 16
20 25
32 40
50 63
2P,3P,4P
3P,4P
3P
400 500 700 800
630 700 1000
800
1250
690
16 20 100 125 200 350 400 500
25 30 160 180 250 315 630
32 40 200 225 400
50 63
80 100
800
690/750
6000
8000
6000/8000
6000
400
400 / 690
400
400
690
65
45
42
34
400
70
50
40
30
85
45
-
60
1000
4000
20
500
2500
20
500
2500
150
200
135
190
240
300
50
25
30
18
Arcing distance mm 50
Durability Cycles/h
120
Electrical
4000
Mechanical 6000
Power consumpution (W)
Fixed
25
Plug-in
30
50
35
30
26
50
35
30
26
120
1500
8500
120
1000
7000
70
50
40
30
100
60
1000
4000
40
50
60
75
40
110
690
Constructional features
Thermamagnetic release offers instantaneous trip against short-circuit and long
time delay trip against overcurrent
The circuit breaker can be fixed type or plug-in type
For 4-pole circuit breakers:
N-pole without overcurrent release, it switches on and off with other poles ( N-pole
lead-make, lag-break)
Various accessories can be attached to the circuit breaker to extend its functions,
such as undervoltage release, shunt release, ON/OFF position indication contact,
and tripped position indication contact, for detail see the accessories part
52
CDM1 Moulded Case Circuit Breaker
Standard: IEC 60947-2
Accessories
The accessories are fixed into the circuit breaker.
■ Remote tripping:
MX or MN releases are used to trip the circuit breaker.
■ This release trips the circuit breaker when the control voltage drops below the tripping threshold:
□ Tripping threshold between 35% to 70% of the rated voltage
□ Circuit-breaker closing is possible only if the voltage exceeds 85% of the rated
voltage.
■ Circuit-breaker tripping by an MN release meets the requirements of standard
IEC 60947-2.
power source input
MN (Undervoltage Release)
■
□
□
230V, 400V AC
(0.35~0.7) Ue
(0.85~1.1) Ue
MX shunt release:
The MX release trips the circuit breaker when the control voltage rises above
0.7 x Un.
Control signals can be of the impulse type (u 20 ms) or maintained.
MX (Shunt Release)
Technical data
power source input
Rated control voltage US(V)
Operating voltage(V)
■
□
□
■
□
□
230V, 400V AC
(0.7~1.1) US
Indication contacts:
These common-point changeover contacts can be used to remotely indicate
circuit-breaker status information for indications, electrical locking, relays, etc.
They comply with international standard IEC 60947-5.
Functions:
OF (ON/OFF): indicates the position of the circuit-breaker contacts.
SD (trip indication): indicates that the circuit-breaker has tripped due to: v overload
v short-circuit v operation of a voltage release v operation of the“push-to-trip”
button Returns to de-energised state when the circuit breaker is reset.
OF (Auxiliary Contactor)
Auxiliary Contact wiring diagram
Technical data
Rated thermal current Ith 3A
Rated operating current
1NO+1NC (Change over)
2NO+2NC (Change over)
0.4A (400V AC)
SD (Alarm Contactor)
“Trip” position
Arm Switch wiring diagram
Technical data
Rated thermal current Ith 3A
Rated operating current
1NO+1NC
0.26A (400V AC)
0.4A (400V AC)
53
Low-voltage
Rated operating voltage Ue(V)
Drop-out voltage(V)
Pick-up voltage(V)
Distribution
Technical data
CDM1 Moulded Case Circuit Breaker
Standard: IEC 60947-2
Overall Dimensions
Low-voltage
Distribution
Type
Poles Overall Dimensions
L
L1
W
H
H1
H2
a
b
Φd
CDM1-63L
3
135
21
76
89
74
21
25
117
3.5
CDM1-63M
3
135
21
76
99
82
28
25
117
3.5
CDM1-63M
4
135
21
103
99
82
28
25
117
3.5
CDM1-100M
2
150
51
65
103
87
24
--
129
4.5
CDM1-100L
3
150
51
92
87
68
25
30
129
4.5
CDM1-100M
3
150
51
92
103
87
24
30
129
4.5
CDM1-100M
4
150
51
122
103
87
24
30
129
4.5
CDM1-225M
2
165
64
75
124
104
24
--
126
5.5
CDM1-225L
3
165
64
107
108
87
24
35
126
5.5
CDM1-225M
3
165
64
107
124
104
24
35
126
5.5
CDM1-225M
4
165
64
142
124
104
24
35
126
5.5
CDM1-400L,M
3
257
105 140
146
100
36
44
215
6.5
CDM1-400M
4
257
105 184
146
100
36
44
215
6.5
CDM1-630L,M
3
270
118
182
160
108
41
58
200
7
CDM1-630M
4
270
118
240
160
108
41
58
200
7
CDM1-800L,M
3
280
102 210
146
103
34
70
243
7
CDM1-800M
4
280
102 280
146
103
34
70
243
7
CDM1-1250M
3
406
104 210
190
140.5
58
70
375
10
Install dimensions
Unit:mm
2P
■
3P
4P
e
Overall and cut-out diagram of round handle
hinge
54
CDM1 Moulded Case Circuit Breaker
Standard: IEC 60947-2
■
Overall and cut-out diagram of square handle
hinge
■
Centrally revolvable type
Unit:mm
■
H
49
54
54
76
83
76
Eccentrically rotating
Unit:mm
Dimension for handle mechanism(eccentrically revolvable type)
Frame
CDM1-100
CDM1-225
CDM1-400
CDM1-630
CDM1-800
A
35
35
65
60
48
B
11.5
31
15
15
15
H
46
48
61
61
66
55
Low-voltage
Distribution
Dimension for handle mechanism(centrally revolvable type)
A
B
Frame
117
25
CDM1-63
129
30
CDM1-100
126
35
CDM1-225
215
44
CDM1-400
200
58
CDM1-630
243
70
CDM1-800
CDM1 Moulded Case Circuit Breaker
Standard: IEC 60947-2
Characteristic Curve of Circuit Breaker
max
max
max
min
min
min
Instantaneous current
Low-voltage
Distribution
Delay trip
Instantaneous current
Delay trip
Instantaneous trip
For power distribution
CDM1-63 Time / current characteristic curve
Delay trip
Instantaneous trip
For power distribution
CDM1-100 Time / current characteristic curve
max
max
min
min
Delay trip
Delay trip
Instantaneous trip
Instantaneous trip
For power distribution
Delay trip
Delay trip
Instantaneous trip
Instantaneous trip
For power distribution
CDM1-400 Time / current characteristic curve CDM1-630 Time / current characteristic curve
56
Delay trip
Instantaneous trip
Instantaneous trip
For power distribution
CDM1-225 Time / current characteristic curve
CDM1LE Earth-Leakage Circuit Breaker
Standard: IEC 60947-2
Function
Constructional features
Thermamagnetic release offers instantaneous trip against short-circuit and
long time delay trip against overcurrent
The residual operating current value can be fixed or adjustable
The residual operating current protection can be with time-delay or without time-delay
Various accessories can be attached to the circuit breaker to extend its functions,
such as undervoltage release, shunt release, ON/OFF position indication contact,
and tripped position indication contact, for detail see the position indication contact,
for detail see the accessories part
Product name
Frame current
Breaking capacity
Current
Pole
CD
M1LE
100
M
16
3
100:100A
225:225A
400:400A
L: L type
M: M type
16: 16A
…
400: 400A
3:3 pole
4:4 pole
Usage
Blank for
distribution
protection
Residual current
N Pole
L
A
S:30mA
Y:100mA
T:300mA
F:500mA
KY:30/100/500mA
KT:100/300/500mA
For CDM1LE
4pole:
A=A type
(Direct connect)
B=B type
(Direct connect,
lead-make, lag
break)
57
Low-voltage
Country code
Distribution
Coding System
CDM1LE Earth-Leakage Circuit Breaker
Standard: IEC 60947-2
Order Information
Type
CDM1LE-100 3P
Low-voltage
Distribution
4P A
4P B
CDM1LE-225 3P
4P A
4P B
Note:* express residual current.
58
Rated
current In A
16
20
25
32
40
50
63
80
100
16
20
25
32
40
50
63
80
100
16
20
25
32
40
50
63
80
100
100
125
140
160
180
200
225
100
125
140
160
180
200
225
100
125
140
160
180
200
225
Reference
Type M
CDM1LE100M163*
CDM1LE100M203*
CDM1LE100M253*
CDM1LE100M323*
CDM1LE100M403*
CDM1LE100M503*
CDM1LE100M633*
CDM1LE100M803*
CDM1LE100M1003*
CDM1LE100M164*A
CDM1LE100M204*A
CDM1LE100M254*A
CDM1LE100M324*A
CDM1LE100M404*A
CDM1LE100M504*A
CDM1LE100M634*A
CDM1LE100M804*A
CDM1LE100M1004*A
CDM1LE100M164*B
CDM1LE100M204*B
CDM1LE100M254*B
CDM1LE100M324*B
CDM1LE100M404*B
CDM1LE100M504*B
CDM1LE100M634*B
CDM1LE100M804*B
CDM1LE100M1004*B
CDM1LE225M1003*
CDM1LE225M1253*
CDM1LE225M1403*
CDM1LE225M1603*
CDM1LE225M1803*
CDM1LE225M2003*
CDM1LE225M2253*
CDM1LE225M1004*A
CDM1LE225M1254*A
CDM1LE225M1404*A
CDM1LE225M1604*A
CDM1LE225M1804*A
CDM1LE225M2004*A
CDM1LE225M2254*A
CDM1LE225M1004*B
CDM1LE225M1254*B
CDM1LE225M1404*B
CDM1LE225M1604*B
CDM1LE225M1804*B
CDM1LE225M2004*B
CDM1LE225M2254*B
Type L
CDM1LE100L163*
CDM1LE100L203*
CDM1LE100L253*
CDM1LE100L323*
CDM1LE100L403*
CDM1LE100L503*
CDM1LE100L633*
CDM1LE100L803*
CDM1LE100L1003*
CDM1LE100L164*A
CDM1LE100L204*A
CDM1LE100L254*A
CDM1LE100L324*A
CDM1LE100L404*A
CDM1LE100L504*A
CDM1LE100L634*A
CDM1LE100L804*A
CDM1LE100L1004*A
CDM1LE100L164*B
CDM1LE100L204*B
CDM1LE100L254*B
CDM1LE100L324*B
CDM1LE100L404*B
CDM1LE100L504*B
CDM1LE100L634*B
CDM1LE100L804*B
CDM1LE100L1004*B
CDM1LE225L1003*
CDM1LE225L1253*
CDM1LE225L1403*
CDM1LE225L1603*
CDM1LE225L1803*
CDM1LE225L2003*
CDM1LE225L2253*
CDM1LE225L1004*A
CDM1LE225L1254*A
CDM1LE225L1404*A
CDM1LE225L1604*A
CDM1LE225L1804*A
CDM1LE225L2004*A
CDM1LE225L2254*A
CDM1LE225L1004*B
CDM1LE225L1254*B
CDM1LE225L1404*B
CDM1LE225L1604*B
CDM1LE225L1804*B
CDM1LE225L2004*B
CDM1LE225L2254*B
CDM1LE Earth-Leakage Circuit Breaker
Standard: IEC 60947-2
Order Information
Type
CDM1LE-400 3P
4P A
Type L
CDM1LE400M2003*
CDM1LE400M2503*
CDM1LE400M3153*
CDM1LE400M3503*
CDM1LE400M4003*
CDM1LE400L2003*
CDM1LE400L2503*
CDM1LE400L3153*
CDM1LE400L3503*
CDM1LE400L4003*
200
CDM1LE400M2004*A
CDM1LE400L2004*A
225
CDM1LE400M2254*A
CDM1LE400L2254*A
250
CDM1LE400M2504*A
CDM1LE400L2504*A
315
CDM1LE400M3154*A
CDM1LE400L3154*A
350
CDM1LE400M3504*A
CDM1LE400L3504*A
400
CDM1LE400M4004*A
CDM1LE400L4004*A
200
CDM1LE400M2004*B
CDM1LE400L2004*B
225
CDM1LE400M2254*B
CDM1LE400L2254*B
250
CDM1LE400M2504*B
CDM1LE400L2504*B
315
CDM1LE400M3154*B
CDM1LE400L3154*B
350
CDM1LE400M3504*B
CDM1LE400L3504*B
400
CDM1LE400M4004*B
CDM1LE400L4004*B
Note:* express residual current.
Order Information for Accessories
Voltage
(V)
Type
Reference
MN*
230V AC
400V AC
CDM1LE-100 CDM1LE100MN230*
CDM1LE100MN400*
CDM1LE-225 CDM1LE225MN230*
CDM1LE225MN400*
CDM1LE-400 CDM1LE400MN230*
MX*
OF
SD
TS(Square Handle)
CDM1LE100MX230* CDM1LE100OF* CDM1LE100SD* CDM1LE100TS
CDM1LE100MX400*
CDM1LE225MX230* CDM1LE225OF* CDM1LE225SD* CDM1LE225TS
CDM1LE225MX400*
CDM1LE400MX230* CDM1LE400OF* CDM1LE400SD* CDM1LE400TS
TR(Round Handle)
CDM1LE100TR
CDM1LE225TR
CDM1LE400TR
CDM1LE400MN400* CDM1LE400MX400*
Note 1: MN and MX could be sold with CDM1LE product and installed by manufactory
2: *means the connecting type;
Blank: terminal connection;
D5: 500mm wire connection
59
Low-voltage
Type M
200
250
315
350
400
Distribution
4P B
Reference
Rated
current In A
CDM1LE Earth-Leakage Circuit Breaker
Standard: IEC 60947-2
Technical Data
Type
CDM1LE-100
CDM1LE-225
CDM1LE-400
Frame size rated current A
100
225
400
Rated current In A
16 20 25 32 40
100 125 140 160
200 250 315
50 63 80 100
180 200 225
350 400
Rated frequency Hz
50/60
Rated insulation voltage Ui V
800
Rated operational voltage Ue V
400
Rated impulse withstand voltage Uimp V 8000
Number of poles
3P, 4P
Low-voltage
Distribution
Icu kA
Type M
50
50
_
(400V)
Type L
35
35
50
Ics kA
Type M
35
35
_
(400V)
Type L
22
22
30
Rated residual
Without delay 30/100/500
30/100/500
100/300/500
100/300/500
100/300/500
100/300/500
100/300/500
100/300/500
1/2 IΔn
1/2 IΔn
1/2 IΔn
Electrical
1500
1000
1000
Mechanical
8500
7000
4000
Total
10000
8000
5000
operating current
IΔn (mA)
With delay
Rated residual non-operating
current IΔn(mA)
Durability
Maximum break time for residual operating current protection
Number of poles
IΔn
2 IΔn
5 IΔn
10 IΔn
Max. break
Without delay
0.2
0.1
0.04
0.04
time S
With delay
0.5/1.15/2.15
0.35/1/2
0.25/0.9/1.9
0.25/0.9/1.9
Table for 4 pole CDM1LE (Neutral line)
Code
Note
A
N(direct connect)
B
N(direct connect N pole lead-make, lag-break)
Constructional features
Thermamagnetic release offers instantaneous trip against short-circuit and long time delay trip
against overcurrent
The residual operating current value can be fixed
fxed or
or adjusted
adjusted
The residual operating current protection can be with time-delay or without time-delay
Various accessories can be attached to the circuit breaker to extend its functions, such as
undervoltage release, shunt release, ON/OFF position indication contact, and tripped position
indication contact, for detail see the accessories part
60
CDM1LE Earth-Leakage Circuit Breaker
Standard: IEC 60947-2
Handle mechanism
■
Centrally revolvable type
Unit:mm
■
Square Handle
CDM1LE-100
CDM1LE-225
CDM1LE-400
Dimension
49
55
74
Accessories
The accessories are fixed into the circuit breaker.
■ Remote tripping:
MX or MN releases are used to trip the circuit breaker.
■ This release trips the circuit breaker when the control voltage drops below the trip
ping threshold:
□ tripping threshold between 0.35 and 0.7 times the rated voltage
□ circuit-breaker closing is possible only if the voltage exceeds 0.85 times the rated
voltage.
■ Circuit-breaker tripping by an MN release meets the requirements of standard
IEC 60947-2.
MN (Undervoltage Release)
Technical data
Power source input
Rated operating voltage Ue(V)
Drop-out voltage(V)
Pick-up voltage(V)
230V, 400V AC
(0.35~0.7) Ue
(0.85~1.1) Ue
61
Low-voltage
Distribution
Dimension for handle mechanism
Frame
CDM1LE Earth-Leakage Circuit Breaker
Standard: IEC 60947-2
■
□
□
MX shunt release:
The MX release trips the circuit breaker when the control voltage rises above
0.7 x Un.
Control signals can be of the impulse type (u 20 ms) or maintained.
MX (Shunt Release)
Technical data
Rated control voltage Us(V)
Operating voltage(V)
■
□
Power source input
□
Low-voltage
Distribution
■
□
□
230V, 400V AC
(0.7~1.1) Us
Indication contacts:
These common-point changeover contacts can be used to remotely indicate
circuit-breaker status information for indications, electrical locking, relays, etc.
They comply with international standard IEC 60947-5.
Functions:
OF (ON/OFF): indicates the position of the circuit-breaker contacts.
SD (trip indication): indicates that the circuit-breaker has tripped due to: v overload
v short-circuit v operation of a voltage release v operation of the“push-to-trip”
button Returns to de-energised state when the circuit breaker is reset.
OF (Auxiliary Contactor)
Auxiliary Contact wiring diagram
Technical data
Rated thermal current Ith 3A
Rated operating current
1NO+1NC (Change over)
2NO+2NC (Change over)
0.4A (400V AC)
SD (Alarm Contactor)
“Trip” position
Arm Switch wiring diagram
Technical data
Rated thermal current Ith 3A
Rated operating current
1NO+1NC
62
0.26A (400V AC)
0.4A (400V AC)
CDM1LE Earth-Leakage Circuit Breaker
Standard: IEC 60947-2
Overall Dimensions
Unit:mm
Type
Poles Overall size
L1
CDM1LE-100L 3
92max
4
122max
CDM1LE-100M 3
92max
4
122max
CDM1LE-225L 3
107max
4
142max
CDM1LE-225M 3
107max
4
142max
CDM1LE-400L,M 3
150max
4
198max
L2
150max
150max
150max
150max
165max
165max
165max
165max
257max
257max
L3
94max
94max
110max
110max
94max
94max
110max
110max
150max
150max
L4
75max
75max
92max
92max
72max
72max
90max
90max
107max
107max
Installation size
a b
Φd
30 129 4×Φ4.5
60 129 6×Φ4.5
30 129 4×Φ4.5
60 129 6×Φ4.5
35 126 4×Φ4.5
70 126 6×Φ4.5
35 126 4×Φ4.5
70 126 6×Φ4.5
48 194 4×Φ4.5
95 194 6×Φ6.5
63
Low-voltage
Distribution
Key to Overall Dimensions
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
Application
Applied to power distribution of AC 50Hz/60Hz, rated operational voltage 400/690V,
rated current 200A~6300A and lower
For power distribution and protecting circuit and power supply equipment aganist
harm from overload, undervoltage, short circuit, earthing, and other faults
Circuit breaker which ampere frame size is under 630A can protect motor aganist
overload,undervoltage and shortcircuit
Core parts use intelligent control unit which has accurate discrimination protection,
it can avoid unnecessary power failure and enhance the reliability of power supply
system
Standard and Certification
Low-voltage
Distribution
Standard: IEC60947-2
Approved certification: CB, CE, KEMA
Operating condition and installation recommendation
Ambiant temperature
Altitude
Environmental humidity
Degree of pollution
Installation position
Category of installation
64
Ambient temperature shall be controlled between
+40℃ and -5℃, the average temperature in 24
hours shall not exceed +35℃
Note:contacting manufacturer about circuit breaker
used in place where ambient temperature is higher
than +40℃ or lower than -5℃
Altitude of installation position shall not exceed than
2000m
The relative humidity of the installation position shall
not exceed 50% when the maximum temperature
reached +40℃, but there can be higher relative
humidity under lower temperature, for example,
i t c a n r e a c h 9 0 % a t 2 0℃. C o n s i d e r i n g t h a t
condensation occurred on product surface when
temperature changes
Ⅲ
Vertically mounting, tolerance on slope in any
direction shall not exceed 5°
Main circuit and undervoltage trip coil, power
transformer primary coil:Ⅵ
Auxiliary circuit,control circuit:Ⅲ
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
Parameter and characteristics
Certification approved: IEC 60947-1 IEC 60947-2
Type
CDW7-1000
CDW7-2000
CDW7-3200
CDW7-6300
Number of poles
3, 4
3, 4
3, 4
3, 4
Utilization categories
B
B
B
B
Arc-over distance (mm)
0
0
0
0
400
400/690
400/690
400
Ui
690
800
800
800
Rated impulse withstand voltage (V)
Uimp
8000
8000
8000
8000
50
50
50
50
200/400/630
630/800/1000
2000/2500
4000/5000
/800/1000
/1250/1600/2000
/3200
/6300
AC 400V
42
65
80
120
AC 690V
--
50
65
--
AC 400V
30
50
80
100
AC 690V
--
40
50
--
AC 400V
88
176
220
264
AC 690V
--
105
143
--
AC 400V
30
40
50
85
AC 690V
--
40
50
--
mechanical
9000
9000
4500
1500
electrical
1000
1000
500
500
Rated frequency (Hz)
Rated current (A)
In
Rated ultimate short circuit breaking capacity (kA) Icu
Rated service short circuit breaking capacity (kA)
Rated short circuit making capacity (kA)
Rated short circuit withstand current (kA)
Service life(c/o cycles)
Ics
Icm
Icw
65
Low-voltage
Ue
Rated insulation voltage (V)
Distribution
Rated opertional voltage (V)
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
Protection characteristics
structural feature of ESW series intelligent controller
Interlocking device
Floor plate
Contactor
Device
Chassis
Controller
Accessories
Reset devise
Magnetic flux converter
Basic circuit
Chassis and other units
Sensor
Mutual inductor
Power supply
accessories
AC power supply
DC power supply
UPS
Relay
Low-voltage
Distribution
Outline and operation of ECW series intelligent controller
ECWS-H (Applicable to CDW7-1000)
ELECTRIC
ECWS-H
1
2
ECWS-H
3
Ir1
RESET
4
Warn/ Alarm
Healthy
Ir2
Bus
5
Isd
Ir4
Ir3
6
SEPECIFICATION
1-LCD interface display
2-Fault and alarm reset button
3-“Fault/Alarm” LED
In normal state, this LED is off.
In case of fault release, the red LED will flash quickly; in case of
alarm, the red LED will be on constantly
4-“Normal” LED
As long as the controller is on and operates normally, the green
LED always flashes
5-Communication indicator
The communication state indication is as follows:
Profibus: OFF if no communication; ON if communication exists
Modbus: OFF if no communication; flash if communication exists
Device Net: Flash if no communication; ON if communication exists
6-Curve LEDs
Red LEDs exist behind the curve.
In case of fault release, the corresponding LED will flash
indicating the fault type;
During the parameter setting process, the LED is always on and
indicates the current item.
Keypad
66
7
8
9
10
11
12
13
14
7-Measure key l, used to switch to the default measurement menu.
8-Set key 2, used to switch to the parameter setting menu.
9-Protection Key 3, used to switch to the protection parameter setting menu.
10-Info key 4, used to switch to the historical record and maintenance menu.
11-Up, Move up the cursor through the menu items on the current level, or
increment the value of the selected parameter.
12-Down, Move down the cursor through the menu items on the current
level, or decrement the value of the selected parameter.
13-Exit, exit from the current level and return to the upper level, or cancel the
current parameter selection.
14-Select, Select to enter into the next level from the current item, or select the
current parameter, or store the change.
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
ECW-M(applicable to CDW72000/3200/6300)
1
ECW-M
2
3
4
5
8
67
Low-voltage
7
1-Reset button of Fault release
In case of breakers tripping, breakers cant be reclosed until this button is
pressed.
2-voltmeter display
Display the phase current ,normally display the Max.phase current.
3-light—emitting diode Indicators
Display Setting , test , fault and Categorization
4-Ammeter display
Display each of the phase current value and earth or leakage current value.
Normally display Max. phase current value and can display the value of
setting , test and fault current or time .
5-Key button
Setting , test, check various state and Categorization
6-“lighting clear ”or “reset ”button
When it is pressed ,the controller enters into normal run state , The breaker
cant be closed until the button is pressed in case of setting, test, fault.
7-Shaft hole for test current
8-Shield
As soon as the controller enters into normal run state ,the shield need to be
sealed to protect the setting parameter.
Distribution
6
SEPECIFICATION
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
ECW-H (enhanced type ,applicable to CDW7 2000/3200/6300)
SPECIFICATION
ELECTRIC
1
ECW-H
2
3
4
Low-voltage
Distribution
Ir1
RESET
5
Warn/ Alarm
Healthy
Ir2
Bus
6
Isd
Ir4
Ir3
7
1-Mechanical reset button(the button will pop up when fault tripping or test tripping,
circuit breaker won’t be closed without pressing down,when the button is
pressed down,fault indication is reset immediately)
2-LCD display screen
3-Warn and alarm reset
4-Warn/ alarm LED
When normally operated, LED is off
When fault tripping , red LED will blink quickly
When alarming, red LED is opening eternally
5-“Healthy” LED:green LED will blink continuously as long as the controller is
energized and operating healthily
6-Communication lamp
Communication status is indicated as follows
Profibus:off when without communication,on uninterrupted when in communication
Modbus:off when without communication,blinking when in communication
Device Net:blinking when without communication,on uninterrupted when in
communication
7-Curve LED
A red LED lamp is hided in curve
When triped by failure , the regarding LED will blink to indicate the failure type,
when the protection reference is set, the lighting LED will indicate the set option
8-There is a 16pin test connector in the bottom of front plate of test terminal,you can
insert a plug-in portable power box and inspection -unit
Keypad
8
TEST
68
9
10
11
12
13
14
15
16
9-Measurement function key1, navigated to measurement default theme menu
10-Setting function key2, navigated to parameter setting theme menu
11-Protection function key3, navigated to protection parameter setting theme menu
12-Information function key4, navigated to history and maintenance theme menu
13-Move upwards from the current used level to change the menu content,or change
the selected parameter
14-Move downwards from the current used level to change the menu content,or
change the selected parameter
15-Exit the current used level to back the parent menu,or cancel the current
parameter
16-Choose to enter the currrent programme leading to son menu,or select the
current
parameter, store the modification
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
ECW series intelligent controller function feature
Intelligent controller function
ECWS- H
Basic function
Addtional function*
Protection
Different curves available
Measurement
Maintenance
Human-machine Digital
Four phase current (I1,
Up to 8 fault logs
LCD display of
MCR and out-of-limit
for long time delay
I2, I 3, IN) and earth
Up to 8 alarm logs
Chinese GUI
tripping protection
protection
current
Up to 8 position logs
LED indication
DO Signal alarm function
Different curves available
Thermal capacity
Historical current peak
Key operation
Communication function
Contact equivalence
for inverse short time
Number of operating
delay protection
cycles
Definite short time delay
Clock function
protection
Self-diagnosis function
Instantaneous protection
phase) protection
Earth protection
Earth fault alarm
Neutral phase protection
Load monitor
ECW - M
Long time delay protection
Max. phase current
Fault log
Digital display
DO Signal alarm function
Definite time delay +
Four phase current (I1,
Self-diagnosis
LED indication
MCR and out-of-limit
I2, I 3, IN) and earth
function
Key operation
tripping protection
current
Feature test function
Digital setting of
Earth fault or leakage
protection parameters
protection (either)
inverse time delay for
short time delay protection
Instantaneous protection
Earthing protection
Load monitor
Different curves available
ECW - H
for long time delay
Four phase current (I1,
Up to 8 fault logs
LCD display of Chinese Over-voltage protection
protection
I2, I 3, IN) and earth
Up to 8 alarm logs
GUI
Under-voltage protection
current
Up to 8 position logs
LED indication
Voltage unbalance
Thermal capacity
Historical current
Key operation
protection
Different curves available
for inverse short time
delay protection
Definite short time delay
protection
Instantaneous protection
MCR and out-of-limit
tripping protection
Current unbalance (open
peak
Over-currency protection
Contact equivalence
Under-frequency
Number of operating
protection
cycles
Phase protection
Fault clock function
Inverse power protection
Self-diagnosis fault
Demand protection
log
Zonal system interlock
Self-diagnosis
protection
phase) protection
function
Communication function
Earth protection
Feature test function
Earth fault alarm
Neutral phase protection
Load monitor
note:* can measure voltage,frenquency,voltage unbalance rate,phase-sequency detection, power,energy,demand paramteter(current,power),harmonic
69
Low-voltage
Distribution
Current unbalance (open
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
Basic protection
Long time
CDW7-1000
CDW7-2000~6300
Basic configuration
ECWS-H intelligent
ECW-M intelligent controllers ECW-H intelligent controllers
of ECW intelligent controller
controllers
Current Setting
Ir1=(0.4~1)ln
Ir1=(0.4~1)ln
Ir1=(0.4~1)ln
Action
conventional non-tripping 1.05×Ir1 h
characteristics conventional tripping
≥2h
≥2h
≥2h
1.3×Ir1 h
≤2h
≤1h
≤1h
1.5Ir1
8,12.8,19.2,32,48,64,80,108 15,30,60,120,240,480
15,30,60,120,240,360,480,60
,144,224,320,480,640,800,9
0,720,840,960
60,1120
2.0Ir1
3.32,5.32,8.00,13.32,20.00,
8.4,16.9,33.8,67.5,135,270
Low-voltage
Distribution
26.66,33.30,45.00,60.00,93.
8.4,16.9,33.8,67.5,135,202.5,
270,337.5,405,472.5,540
32,133,200,266,333,400,43
3
3.0Ir1
1.25,2.00,3.00,5.00,7.50,10.
0,12.5,16.8,22.5,35.0,50.0,7
5.0,100,125,150,162
Short time
Current setting
Ir2=(1.5~15)In
Ir2=(0.4~15)In
Ir2=(1.5~15)In
Accuracy
±15%
±10%
±10%
Ts=K/10(N2-1),(Ts≥20ms)
I2Ts=(8Ir1)2ts
Ts=K/10(N2-1),(Ts≥20ms)
Time setting(S) 0.1,0.2,0.3,0.4
0.1,0.2,0.3,0.4
0.1,0.2,0.3,0.4
Resettable time(S) 0.06,0.13,0.2,0.27
0.06,0.16,0.25,0.34
0.06,0.13,0.2,0.27
Action
Inverse time-limit
characteristics Definite time-delay
Instantaneous
ECWS-H
ECW-H
ECW-M
CDW7-3200
CDW7-6300
CDW7-1000~6300A
CDW7-2000
Current setting
(1.0~20)ln
Ir3=1In~50KA+OFF Ir3=1In~75KA+OFF IIr3=1In~100KA+OFF
Accuracy
±15%
±15%
Ir4=(0.2~1.0)In
Ir4=(0.2~1.0)In
Ir4=(0.2~1.0)In
±10%
±10%
±10%
±15%
±15%
Earth fault
Current setting
Accuracy
Action
Inverse time-limit
characteristics Definite time-delay
Time setting
0.1s~1s (Rank difference 0.1s) 0.1~0.4s (Rank difference 0.1s) 0.1s~1s(Rank difference 0.1s)
note:*pick-up shall not be crossed due to having three-stage protection simultaneously
70
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
Auxiliary Functions
undervoltage release
The undervoltage release automatically opens a circuit breaker when voltage
drops to a value ranging between 35% to 70% of the line voltage. after tripping,the
circuit breaker cannot be re-closed again when the voltage lowers than 35% or
until returns to 85% of line voltage.
Undervoltage release
AC 380V
AC220V
(0.35~0.7)Ue
(0.35~0.7)Ue
(0.85~1.1)Ue
(0.85~1.1)Ue
≤0.35Ue
≤0.35Ue
CDW7-2000~6300
36VA
24VA
CDW7-1000
5VA
5VA
Rated operational voltage
Operation voltage
Ue V
V
Range of closing voltage V
Range of non-closing voltage
Consumption
V
Shunt release
Power supply
Us V
AC380
AC220
DC220
Consumption
CDW7-2000~6300
36VA
24VA
24W
24W
CDW7-1000
5VA
5VA
5W
5W
Operational voltage
V
DC110
(0.7~1.1)Us
less than 30ms
Breaking time
Closing voltage release
Closing release shall close the circuit breaker when supply voltage drops to a
value ranging between 85% to 110%
Closing voltage release
Power supply
Us V
AC380
AC220
DC220
DC110
Consumption
CDW7-2000~6300
36VA
24VA
24W
24W
CDW7-1000
10VA
10VA
10W
10W
Operational voltage
Breaking time
V
(0.85~1.1)Us
less than 70ms
71
Low-voltage
Distribution
Shunt release
The shunt release shall open the circuit breaker when the supply drops to a value
ranging between voltage rise between 70% to 110% of the line voltage
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
Electric motor
Motor operator shall complete energy storage when line voltage rise to between
85% to110%
Motor operator structure
Rated control power supply volage Us V
AC380
AC220
DC220
DC110
85VA
85VA
85VA
85VA
2000~6300 2000A<In≤3200A
110VA
110VA
110VA
110VA
3200A<In≤6300A
150VA
150VA
150VA
150VA
CDW7-1000
Operational voltage V
80VA
80VA
80VA
80VA
Energy storage time
less than 5s
In≤2000A
CDW7Power
consumption
(0.85~1.1)Us
Low-voltage
Distribution
Auxiliary switch
Making and breaking capacity of auxiliary contact under normal or abnormal conditions
Utilizaiton category
AC-15
Auxiliary contact default type
Four normal open four normal close
Conventional thermal current Ith
6A
Auxiliary contact's energized operational
Equal to circuit breaker operation
performance
performance
Making&
Under
I/Ie making
10
1
breaking
normal
I/Iebreaking
1
1
capacity
conditions
U/Ue
1
1
cosΦor T0.95
0.3
6Pe*
Under
I/Ie
10
1.1
abnormal
U/Ue
1.1
1.1
0.3
6Pe*
10
10
conditions cosΦor T0.95
operation cycles
note:* when Pe≥50W,T0.95e’s upper limit≤300ms
72
DC-13
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
Overall Dimension
Unit:mm
CDW7-1000A fixed circuit breaker overall and mounting dimension horizonal/vertical
connection diagram
N
6
12
12
8
16
16
73
Low-voltage
Distribution
CDW7-1000A fixed circuit breaker outline and horizonal/vertical connected dimension
Current rating (A)
Pole
L
L1
L2
200, 400
3P
266
244
630
266
244
800, 1000
266
244
200, 400
4P
336
314
70
630
336
314
70
800, 1000
336
314
70
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
CDW7-1000A drawout circuit breaker overall and horizonal/vertical connection
diagram
Low-voltage
Distribution
CDW7-1000A drawout type circuit breaker outline and horizonal/vertical wiring
Current rating (A)
200, 400
630
800, 1000
200, 400
630
800, 1000
74
Pole
3P
4P
L
284
284
284
354
354
354
L1
194
194
194
264
264
264
L2
70
70
70
L3
55
75
75
55
75
75
L4
63
83
83
63
83
83
N
6
12
12
8
16
16
H
6
8
10
6
8
10
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
CDW7-2000A~3200A fixed circuit breaker overall and horizonal/vertical connection
dimension(CDW7-2000)
CDW7-2000A~3200A fixed circuit breaker overall and horizonal/vertical wiring
Type
Pole
L1
L2
L3
L4
In A
a
CDW7-2000*
3P
362
318
292
340
400~800
10
4P
457
413
292
435
1000~1600
15
457
413
292
435
2000
20
3P
422
378
352
400
2000~2500
20
4P
537
493
352
515
3200
30
CDW7-3200
note:* CDW7-2000 mounting dimension is same regardless of different current used in"horizonalwiring" or"vertical-wiring"
75
Low-voltage
Distribution
CDW7-2000A fixed circuit breaker vertical connection diagram
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
door
Low-voltage
Distribution
76
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
CDW7-2000A~6300A drawout type circuit breaker outline and horizonal/vertical connection
Type
Pole
CDW7-2000 1) 3P
CDW7-3200
CDW7-6300
(4000/5000A)
CDW7-6300
4P
3P
4P
3P
4P
3P
L1
375
375
470
435
550
813
928
928
L2
335
335
430
395
510
773
888
888
L3
292
292
292
352
352
352
352
352
L4
265
265
360
325
440
703
818
818
L5
247
247
247
307
307
307
307
307
W1
461
461
461
471
471
494
494
494
W2
507
507
507
517
517
540
540
540
b
179
179
179
189
189
212
212
212
In A
400~800
1000~1600
2000
2000~2500
3200~4000
4000
5000~6300
5000~6300
a
10
15
20
20
30
20
30
30
note: 1) CDW7-2000 the mounting dimension is same regardless of different current used
in"horizonal-connected" or "vertical-connected"
CDW7-1000A drawout type
CDW7-1000A fixed type
CDW7-2000~6300 panel cut-out dimension
CDW7-2000~6300A fixed type
CDW7-2000~6300A drawout type
CDW7-2000~6300 panel cut-out dimension and mounting dimension
Type
a
b
c
3P
4P
CDW7-2000
306
346
0
47.5
CDW7-3200
366
406
0
57.5
CDW7-6300
366
406
189(4000/5000A)
246.5(4000/5000A)
246.5(6300A)
--
77
Low-voltage
Distribution
CDW7-1000 panel cut-out dimension
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
Auxiliary connection diagramn
■
ECWS-H type intelligent release unit connection diagram
Low-voltage
Distribution
1:Q、F、X with different current ratings shall
connect with different sources.
■
2:If users have special requirements£¬the
auxiliary switches can reach up to a maximum
of 6ON6OFF. At this condition, the 45 - 49
output terminals will become the auxiliary switch
contacts. For the detailed wiring diagram , please
see the dotted line part of the diagram. At this
time, the external sensor and supplementary
functions are not available.
■
78
■
Sign interpretation in connection diagram:
----Connected by user
----Connected by manufacturer
SB1 shunt pushbutton(self-prepared) SB2 close pushbutton
SB3 undervoltage pushbutton(self-prepared) X
closing voltage release
FU fuse
F
closing voltage release
DF auxiliary switch
SA electrical path switch
M
electric motor
Q undervoltage instantaneous
lamp(self-prepared)
(or time-delay) release
XT
circuit breaker wiring terminal
41、42 when controller power choose DC,the output is DC24V,user can select DC
power module
□ 43、44 circuit breaker status detection terminal(used when MCR function included)
□ 45 overload pre-alarm signal output
□ 46 automatic diagnosis alarm signal output
□ 47 fault trip alarm signal output
□ 48 earthing but non-tripping,only alarm signal output
□ 49 four groups of contacts output common terminal
□ 50、51 externally sensor input terminal
□ 58 able to directly connect to power supply(automatic pre-energization),also able
to join up with normal open pushbutton to connect to power supply(manual preenergization)
□
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
■
ECW-M intelligent release connection diragram
Components:
Q - Under-voltage release
F - Shunt release
X – Closing electromagnet
DF - Auxiliary switch
M - Motor
SB1—Button for closing
SB2—Button for shunt
Note: 1. If the control voltage values of Q, F, X, and M are different to each other,
these components can be connected to different power supply units; in the application, the shunt release and closing electromagnet shall be connected serially with
normally open and normally closed auxiliary contacts (the part enclosed by dotted
lines shall be connected by the user; the part represented by a two-dot chain line is
the wiring of circuit 51);
Note 2: The pin 35# can be connected to the power supply directly (automatic
pre-energy storage) or connected serially to a normally open button and then to the
power supply (manual pre-energy storage);
Note 3: If the user requests, pin #6~#7 can be connected to normally closed contacts;
Note 4: The ECW power supply module I is a DC power supply module, and it can
be omitted if the power supply is AC power supply; the polarity and lead-ins/lead-outs
shall not be reversed (for draw-out type circuit breakers, the lead-outs of the power
supply module has been connected before the circuit break is shipped from the factory);
Note 5: In case of circuit 47, the auxiliary contacts are four closed and four open
contacts; pin #25 and #26 are input terminals of an external current transformer ,
used for earth fault protection as (3P+N)T type ;
Note 6: In case of circuit 51, the auxiliary contacts are six closed and six open
contacts (or five closed and five open contacts); pin #25, #26, and #51 form normally
open and normally closed contacts;
Note 7: If Profibus or any other protocol is used, ECW-H + DP conversion module
and other conversion modules must be ordered; ECW power supply module lV and
ECW201 relay module must be ordered separately;
Note 8:Pin #12~#19 input/output contacts can be user-defined programmable
signal contacts.
79
Low-voltage
Distribution
Pin functions:
Pin 1# and 2#: Auxiliary power input,pin 1# is positive
for DC input
Pin 3#, 4#, 5#: Fault trip contact output (4# is
common terminal); contact capacity: AC380V, 16A
Pin 6# and 7#, 8# and 9#: Two groups of auxiliary
contacts for breaker status; contact capacity:
AC380V, 16A
12#,13#(Contact1)and 14#,15#(Contact2)and
16#,17#(Contact3)and 18#,19#(Contact4):Output
of four groups of signal for controllers,contact
capacity:4A/240V 7A/24VDC
20#: Earth protection
21#~24#:input of voltage signal (Note:the order cant
be wrong)
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
ECW-H intelligent release connection diagram
■
Low-voltage
Distribution
1: different power supply can be connected respectively if
■
■
the control supply voltage of Q、F、X、M are different the
shunt release、closing release shall respectively,join up with
normal open、normal close auxiliary contacts(the broken
line part of diagram is connected by user own;double point
line is 51 circuit connection)
2: terminal 35# can directly connect to power supply
■
(automatic pre-energy storage),or join up with normal open
pushbutton to connect power supply(manual pre-energy
storage)
3: terminal 6#~7# can lead out normal close contact if user
■
suggested
4: ECW power supply module is DC power supply module,
■
the module doesn't exist when power supply current is
AC,polarity,incoming line and leading-out line shall not
connected reversely(leading-out terminal of power supply
module in drawout type had been connected before sale)
5: in 47 circuit,auxiliary contact is 4 open 4 close;25#、26# is
■
input terminal of external sensor
6: in 51 circuit,auxiliary contact is 6open6close(5open
■
5close);25#、26#、51# form normal open normal close
contact(earth-leakage protection excluded)
■
7: if using profibus or other protocols, user shall order ECWH+HP transformation module and others;ECW power supply
moduleV,ECW201 relay module and others shall order
seperately
8: #12~#19 output input contacts are programmableself-
■
defined signal contaccts
80
components:
Q- undervoltage release
F- shunt release
X- closing voltage release
DF- auxiliary switch
M- electric motor
Pin function:
1#、2#: 1# is the front terminal when DC is supplied by auxiliary power
□ 3#、4#、5#:
fault trip contact output(4 is the common termincaoln)contact capacit: AC380V、16A
□ 6#、7#和8#、9#:
two groups of circuit breaker status auxiliary terminal: contact capacit:AC380V、16A
□ 10#、11#: respectively as the communication leading-out of RS485A ,RS485B
□ 12#: overload pre-alarm signal output
□ 13#: communication remote control shunt release output
□ 14#: communication remote control closing output or instantaneous short time-delay
trip signal output
□ 15#: communication remote control energy storage or long time-delay trip signal output
□ 16#: S-earth(RS-485 transmissionn common ground wire
□ 17#: load monitor output1
□ 18#: load monitor signal 2
□ 19#: signal output common earth wire
□ 20#: PE line ,shield earth wire
□ 21#: neutral voltage signal N phase
□ 22#: voltage signal A phase
□ 23#: voltage signal B phase
□ 24#: voltage signal C phase
■
□
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
Other Additional Parameter
■
ECWS-H ECW-H overcurrent proteciton curver
ECW-M overcurrent protection curve
81
Low-voltage
Distribution
■
CDW7 Air Circuit Breaker
Standard: IEC 60947-2
Order Instruction
Customer
Sets purchased
Date
Mode CDW7
Fixed
Draw-out
Rated voltage
AC400
AC690
Low-voltage
Distribution
H Type Intelligent electronic trip
Basic function
3 Poles
4Poles
Rated current
In= A
Overload long delay
Short-circuit short
Short-circuit instantaneous
time protection
delay time protection
protection
Earthing protection
Load monitoring function
Metering function
(Not available for L type)
Power supply
AC 230V
AC 400V
DC 220V
DC 110V
Under-voltage instantaneous trip
AC 230V
Under-voltage time-delay trip
1s
AC 400V
Under-voltage trip
3s
5s
Accessaries
Shunt trip
AC 230V
AC 400V
DC 220V
DC 110V
Energy releasing electromagnet
AC 230V
AC 400V
DC 220V
DC 110V
Motor Driven
AC 230V
AC 400V
DC 220V
DC 110V
Interphase barrier
Escutcheon
N phase external connection
Earth-leakage CT(Only for cable)
Auxiliary switch
standard(4a4b)
special(6a6b)
Auxiliary Connection Terminal
Mechanical interlock
1-lock,1-key
2-lock,1-key
Steel-cable interlock
Interlocking rod with 2 switches
Interlocking rod with 3 switches
Door interlock(Available for Draw-out type)
Note:for any special requirement,please contact with the manufacturer.
82
3-lock, 2-key
Contents
Motor Control & Protection
Contactor&Thermal Overload Relay
86-127
CDC17-K
Mini AC Contactor
86
CDC17
AC Contactor
89
CDR17
Thermal Overload Relay
100
CJX2
AC Contactor
106
JRS1D
Thermal Overload Relay
112
CJX2-F
AC Contactor
117
JRS2
Thermal Overload Relay
123
Definite Purpose Contactor
128-134
CDC9
Switching Capacitor Contactor
128
CDCK8
Air Condition Contactor
131
135-146
CDZ17
Contactor Relay
135
CDZ8
Miniature Relay
139
JSZ3
Electronic Time Relay
143
XJ9
Phase Failure and Sequence Protection Relay
146
83
Motor Control &
Protection
Relay
Motor Control and Protection Product
Overview
Contactor
Thermal Overload Relay
CDC17-K
86
100
Current:6-12A
Pole:3P,4P
Coil Voltage:AC24-400V
Setting Current:0.1-18A
Trip class:10A
CDC17
CDR17
89
Current:9-185A
Pole:3P
Coil Voltage:AC24-400V
CDC17
89
Motor Control &
Protection
Current:115-1000A
Pole:3P
Coil Voltage:AC110-400V
CJX2
106
100
Setting Current:0.1-185A
Trip class:10A, 10
JRS2
123
Setting Current:55-630A
Trip class:10A,10
JRS1D
112
Current:9-95A
Pole:3P
Coil Voltage:AC36-400V
Setting Current:0.1-93A
Trip class:10A,10
CJX2-F
JRS2
117
Current:115-630A
Pole:3P
Coil Voltage:AC36-400V
84
CDR17-18
123
Setting Current:55-630A
Trip class:10A,10
Motor Control and Protection Product
Overview
Definite Purpose Contactor
CDC9
128
CDCK8
131
Current: 25-65A
Poles: 3P
Current: 25-45A
Poles: 1P,2P
Application: Power factor
correction
Application: Air Conditioner
Features:
A unique limiting module
Effectively inhibit the inrush
current
Features:
Compact
Convenient and reliable
connection
Suitable for high-temperature
enviroment
Motor Control &
Protection
Control Relay
CDZ8
139
Contact:
2Z,3Z,4Z
Coil Voltage:
AC6-220V
DC6-220V
Features:
PCB type and plug-in type
are availble
Convenient installation
High sensitivity
Wide range of application
CDZ17
135
Contact:
13, 22, 31, 40, 04,
44, 53, 62, 71, 80
Coil Voltage:
AC36-380V
DC22-440V
Features:
Large capacity of contacts
Scalable accessories
Longer life
85
CDC17-K Mini AC Contactor
Standard: IEC 60947-4-1
Function
CDC17-K AC contactor provide:
□ Remote make & break of circuits
□ Frequent start and stop of motors
Order Information
Moter
P(kW) 380V
Rated
current(A)
2.2
6
4
9
4
Auxiliary contact
Main contact
12
Reference
Motor Control &
Protection
NO
NC
NO
NC
3
0
1
0
CDC17K63010*·
3
0
0
1
CDC17K63001*·
4
0
0
0
CDC17K64000*·
2
2
0
0
CDC17K62200*·
3
0
1
0
CDC17K93010*·
3
0
0
1
CDC17K93001*·
4
0
0
0
CDC17K94000*·
2
2
0
0
CDC17K92200*·
3
0
1
0
CDC17K123010*·
3
0
0
1
CDC17K123001*·
4
0
0
0
CDC17K124000*·
Reference Description
CDC17-K
6
30
10
* ·
Coil Frequency
Coil Voltage
Auxiliary contact
Main contact
Rate current
Model
Coil voltage code
coil voltage
*
24V
36V
110V
127V
220V
380V
400V
B
C
F
S
M
Q
V
Coil frequency code
86
coil frequency
50Hz
60Hz
·
5
6
CDC17-K Mini AC Contactor
Standard: IEC 60947-4-1
Technical Data
Model
CDC17-K06
CDC17-K09
CDC17-K12
Main circuit characteristics
Rated operational current 380V/400V, AC-3
A
6
9
12
380V/400V, AC-4
A
2.6
3.5
5
660V/690V, AC-3
A
3.5
5
6
660V/690V, AC-4
1.5
2
A
1.2
Rated operational voltage
V
220/230, 380/400, 660/690
Rated insulation voltage
V
690
Rated conventional thermal current
A
16
Pole
Power of controlled
3-phase cage motor
3, 4
220V/230V, AC-3
kW
1.5
2.2
3
380V/400V, AC-3
kW
2.2
4
4
5.5
7.5
kW
3
AC-3
×104 operations
100
cycles/h
1200
×104 operations
20
Operating rate
cycles/h
600
Mechanical durabilities
×104 cycles
1000
Operating rate
Electric durabilities
AC-4
Matched Fuse
Cable connection
RT16-16
Inflexible cable
number of piece
Cross Section of Cable mm2
Motor Control &
Protection
660V/690V, AC-3
Electric durabilities
20
RT16-20
2
4
Coil
Coil voltage(Us)
V
AC 24,36,110,127,220,380,400
Operational voltage
V
85%~110% Us
Drop-out voltage
V
20%~75% Us
Inrush
VA
30
Sealed
VA
4.5
Rated conventional thermal current
V
690
Rated insulation voltage
A
10
Rated operational current 380V, AC-15
A
0.95
220V, DC-13
A
0.15
AC-15
VA
360
DC-13
W
33
Auxliary contact
Control capacity
87
CDC17-K Mini AC Contactor
Standard: IEC 60947-4-1
Working Conditions
■ Ambient temperature:-5℃~+40℃, the daily average temperature ≤ 35℃
■ Altitude: ≤ 2000 m
■ Humidity: Maximum temperature is +40℃, air relative humidity of not more than
50%, at a lower temperature allows a higher relative humidity. For example, 20℃,
when up to 90%, and occasionally due to temperature changes resulting from Gel
should take special measures
■ Pollution Level: 3
■ Installation Type: Ⅲ
■ Installation position: should be installed in the absence of a significant shake and
shock and vibration place
Install Location
Motor Control &
Protection
Overall Dimensions
88
CDC17 AC Contactor
Standard: IEC 60947-4-1
Order Information
Moter
P(kW) 380V
Rate current (A)
4
9
12
5.5
18
7.5
25
11
32
15
10
*
NC
1
0
CDC17910*
0
1
CDC17901*
1
0
CDC171210*
0
1
CDC171201*
1
0
CDC171810*
0
1
CDC171801*
1
0
CDC172510*
0
1
CDC172501*
1
0
CDC173210*
0
1
CDC173201*
40
1
1
CDC174011*
22
50
1
1
CDC175011*
30
65
1
1
CDC176511*
37
80
1
1
CDC178011*
45
95
1
1
CDC179511*
55
115
2
2
CDC1711522*
75
150
2
2
CDC1715022*
90
185
2
2
CDC1718522*
110
225
2
2
CDC1722522*
132
265
2
2
CDC1726522*
160
330
2
2
CDC1733022*
220
400
2
2
CDC1740022*
265
500
2
2
CDC1750022*
335
630
2
2
CDC1763022*
450
800
2
2
CDC1780022*
560
1000
2
2
CDC17100022*
Motor Control &
Protection
9
Reference
NO
18.5
Reference Description
CDC17
Auxiliary contact
Coil voltage code
·
coil voltage
24V
36V
110V
127V
220V
380V
400V
*
B
C
F
S
M
Q
V
Coil Frequency
Coil Voltage
Auxiliary contact
Rate current
Model
Coil frequency code
coil frequency
50Hz
5
60Hz
6
89
CDC17 AC Contactor
Standard: IEC 60947-4-1
Technical Data
CDC17-9
CDC17-12
CDC17-18
CDC17-25
CDC17-32
380V / 400V, AC-3 A
9
12
18
25
32
380V / 400V, AC-4 A
3.5
5
7.7
8.5
12
660V, AC-3
A
6.6
8.9
12
18
21
660V, AC-4
A
1.5
2
3.8
4.4
7.5
660
Model
Main circuit characteristics
Rated operational current
Rated operational voltage
V
380 / 400
Rated insulation voltage
V
690
Rated conventional thermal current
A
20
20
32
40
50
4
5.5
7.5
11
15
5.5
7.5
9
15
18.5
Power of controlled
380V/400V, AC-3
kW
3-phase cage motor
660V, AC-3
kW
AC-3
×10 operations 100
Electric durabilities
Operating rate
cycles/h
Electric durabilities
×10 operations 20
AC-4
Operating rate
1200
4
cycles/h
Mechanical durabilities
80
4
300
800
Motor Control &
Protection
×10 cycles
1000
Coil voltage(Us)
V
AC 24, 36, 48, 110, 127, 220, 230, 380, 400
Operational voltage
V
85%~110%Us
Drop-out voltage
V
20%~75%Us
Inrush
VA
70
110
Sealed
VA
8
11
Heat dissipation
W
1.8~2.7
3~4
4
Coil
Accessories
Auxiliary contact
Time-delay block
Front mount
CDF4
Side mount
-
Front mount
CDLA2 or CDLA3
Mechanical Interlock
CDJL17-1
Matched Relay
CDR17-18
Matched Fuse
Cross Section of Cable
RT16-20
Number of Piece
Flexible cable
Inflexible cable
Weight
90
CDR17-32
1
2
1
2
RT16-32
RT16-40
RT16-50
1
1
1
2
2
mm
2
2.5
4
6
mm
2
4
6
10
0.315
0.335
Kg
0.513
0.510
2
CDC17 AC Contactor
Standard: IEC 60947-4-1
Technical Data
CDC17-40
CDC17-50
CDC17-65
CDC17-80
CDC17-95
380V / 400V, AC-3 A
40
50
65
80
95
380V / 400V, AC-4 A
18.5
24
28
37
44
Model
Main circuit characteristics
Rated operational current
660V, AC-3
A
34
39
42
49
55
660V, AC-4
A
9
12
14
17.3
21.3
Rated operational voltage
V
380 / 400
660
Rated insulation voltage
V
690
Rated conventional thermal current
A
60
80
80
125
125
18.5
22
30
37
45
30
33
37
45
45
Power of controlled
380V/400V, AC-3
kW
3-phase cage motor
660V, AC-3
kW
AC-3
×10 operations 80
Electric durabilities
Operating rate
Electric durabilities
4
cycles/h
AC-4
60
1200
×104 operations 20
cycles/h
300
4
×10 cycles
800
Coil voltage(Us)
V
AC 24, 36, 48, 110, 127, 220, 230, 380, 400
Operational voltage
V
85%~110%Us
Drop-out voltage
V
20%~75%Us
Inrush
VA
200
Sealed
VA
20
Heat dissipation
W
6~10
Operating rate
Mechanical durabilities
600
Motor Control &
Protection
Coil
Accessories
Auxiliary contact
Time-delay block
Front mount
CDF4
Side mount
-
Front mount
CDLA2 or CDLA3
Mechanical Interlock
CDJL17-2
Matched Relay
CDR17-95
Matched Fuse
Cross Section of Cable
Number of Piece
Flexible cable
Inflexible cable
Weight
RT16-63
RT16-80
1
1
mm
2
10
mm
2
16
Kg
1.14
2
2
16
-
25
RT16-100
RT16-125
RT16-200
1
1
2
1
2
50
25
50
25
-
50
-
2
25
-
25
-
50
1.35
91
CDC17 AC Contactor
Standard: IEC 60947-4-1
Technical Data
CDC17-115 CDC17-150 CDC17-185 CDC17-225 CDC17-265 CDC17-330
Model
Main circuit characteristics
Rated operational current
380V/400V, AC-3 A
115
150
185
225
265
330
380V/400V, AC-4 A
52
60
79
85
105
117
660V, AC-3
A
86
110
118
135
170
225
660V, AC-4
69
82
98
118
A
49
61
Rated operational voltage
V
380 / 400
660
Rated insulation voltage
V
690
Rated conventional thermal current
A
150
150
210
225
300
330
Power of controlled
380V/400V, AC-3 kW
55
75
90
110
132
160
3-phase cage motor
660V, AC-3
kW
80
100
110
129
160
220
AC-3
×10 operations 60
Electric durabilities
4
cycles/h
Electric durabilities
×10 operations 20
AC-4
300
1200
Operating rate
4
30
cycles/h
300
4
×10 cycles
600
Coil voltage(Us)
V
AC110,127,220,230,380,400
Operational voltage
V
85%~110%Us
Drop-out voltage
V
20%~75%Us
Inrush
VA
559
695
1198
Sealed
VA
33
45
83
9.5~14
13~15
18~25
Operating rate
Mechanical durabilities
600
Motor Control &
Protection
Coil
Heat dissipation
W
Accessories
Auxiliary contact
Time-delay block
Front mount
-
Side mount
CDFC17-11,CDFC17-12
Front mount
-
Mechanical Interlock
CDJL17-3
Matched Relay
CDR17-185
Matched Fuse
RT16-200
Cross Section of Cable
Weight
92
JRS2-400
RT16-250
RT16-250
RT16-400
1
2
1
2
1
2
1
2
1
2
1
2
Flexible cable
mm2
95
50
120
-
150
-
185
-
240
-
240
-
Inflexible cable
mm2
-
20x3 -
25x3
-
25x3 -
Kg
2.15
Number of Piece
32x4 6.6
32x4 6.6
30x5
CDC17 AC Contactor
Standard: IEC 60947-4-1
Technical Data
Model
CDC17-400
CDC17-500
CDC17-630
CDC17-800
CDC17-1000
380V / 400V, AC-3 A
400
500
630
800
1000
380V / 400V, AC-4 A
138
147
188
242
-
660V, AC-3
A
305
355
460
530
580
660V, AC-4
170
215
-
Main circuit characteristics
Rated operational current
A
135
145
Rated operational voltage
V
380 / 400
660
Rated insulation voltage
V
690
Rated conventional thermal current
A
500
500
800
800
1000
Power of controlled
380V/400V, AC-3
kW
220
265
335
450
560
3-phase cage motor
660V, AC-3
kW
280
335
450
500
560
Electric durabilities
AC-3
Operating rate
Electric durabilities
4
×10 operations 60
cycles/h
AC-4
Operating rate
×10 operations 20
cycles/h
Mechanical durabilities
300
4
4
30
×10 cycles
600
Coil voltage(Us)
V
AC110,127,220,230,380,400
Operational voltage
V
85%~110%Us
Drop-out voltage
V
20%~75%Us
Inrush
VA
780
1050
Sealed
VA
10
12
Heat dissipation
W
8~14
10~18
600
Motor Control &
Protection
Coil
Accessories
Auxiliary contact
Time-delay block
Front mount
-
Side mount
-
Front mount
CDFC17-21
Mechanical Interlock
-
Matched Relay
JRS2-400
JRS2-630
Matched Fuse
RT16-500
RT16-630
RT16-800
RT17-4/1000
150
185
240
-
30x5
40x5
50x5
60x5
Cross Section of Cable
Number of Piece
Flexible cable
Inflexible cable
Weight
RT17-4/-1250
2
mm2
mm
Kg
2
9.36
80x5
22.8
93
CDC17 AC Contactor
Standard: IEC 60947-4-1
CDC17-9~95 Contactor Accessories
Top of auxiliary contact
Mechanical interlocking
module
Air delay head
Motor Control &
Protection
Thermal overload relays
Contactor
9
12
25
32
40
50
Top of auxiliary
contact
2 Poles:CDF411,CDF402,CDF420
4 Poles:CDF404,CDF413,CDF422,CDF431,CDF440
Air delay head
Making time-delay:CDLA2DT0,CDLA2DT2,CDLA2DT4
Breaking time-delay:CDLA3DT0,CDLA3DT2,CDLA3DT4
Mechanical
interlocking
module
CDJL171,CDJL17265,CDJL17295
CDR17-18
Thermal
0.1-0.13-0.15A
overload relays
…
14-16-18
94
18
CDR17-32
4.5-5-6.3A
…
23-25-32
CDR17-95
9-10-12A
…
75-80-95A
65
80
95
CDC17 AC Contactor
Standard: IEC 60947-4-1
CDC17-115~1000 Contactor Accessories
Top of auxiliary contact
Mechanical interlocking
module
Side auxiliary
contact
Air delay head
Thermal overload relays
115
150
185
225
265
330
400
500
Top of auxiliary
contact
2 Poles:CDF411,CDF402,CDF420
4 Poles:CDF404,CDF413,CDF422,CDF431,CDF440
Only applicable for CDC17-115~330
Air delay head
Making time-delay:CDLA2DT0,CDLA2DT2,CDLA2DT4
Breaking time-delay:CDLA3DT0,CDLA3DT2,CDLA3DT4
Only applicable for CDC17-115~330
Side auxiliary
contact
CDFC1711,CDFC1721,CDFC1712
Only applicable for CDC17-115~500
Mechanical
interlocking
module
CDJL173150,CDJL173225,CDJL173330
Only applicable for CDC17-115~330
JRS2-180
Thermal
55-88A
overload relays …
150-180A
JRS2-400
80-125A
…
250-400A
630
800
1000
JRS2-630
320-500A
400-630A
Only applicable for CDC17-115~630
95
Motor Control &
Protection
Contactor
CDC17 AC Contactor
Standard: IEC 60947-4-1
Accessories
CDF4 Top of auxiliary contact
Pole
Contact
Reference
Recommended
Contactor
1
CDF411
CDC17 115~330
0
2
CDF402
CDC17 115~330
2
0
CDF420
CDC17 115~330
0
4
CDF404
CDC17 115~330
1
3
CDF413
CDC17 115~330
2
2
CDF422
CDC17 115~330
3
1
CDF431
CDC17 115~330
4
0
CDF440
CDC17 115~330
Delay Range
Reference
Recommended
Contactor
0.1-3S
CDLA2ON0
CDC17 115~330
0.1-30S
CDLA2ON2
CDC17 115~330
10-180S
CDLA2ON4
CDC17 115~330
0.1-3S
CDLA3OFF0
CDC17 115~330
0.1-30S
CDLA3OFF2
CDC17 115~330
10-180S
CDLA3OFF4
CDC17 115~330
Reference
Recommended
Contactor
CDFC1711
CDC17 115~330
CDFC1721
CDC17 115~330
CDFC1712
CDC17 115~330
NO
NC
1
Wiring diagram
2P
4P
Motor Control &
Protection
CDLA Air delay head
Delay Type
Wiring diagram
Making
time-delay
Breaking
time-delay
CDFC17 Side auxiliary contact
Pole
2P
Contact
NO
NC
1
1
2
1
Wiring diagram
13 23 31
3P
14 24 32
1
96
2
CDC17 AC Contactor
Standard: IEC 60947-4-1
Accessories
Mechanical interlocking module
Contactor Specifications
Reference
CDC17-9~32A
CDJL171
CDC17-40~65A
CDJL17265
CDC17-80~95A
CDJL17295
CDC17-115~150A
CDJL173150
CDC17-185~225A
CDJL173225
CDC17-265~330A
CDJL173330
Working Conditions
Motor Control &
Protection
■ Ambient temperature:-5℃~+40℃, the daily average temperature ≤ 35℃
■ Altitude: ≤ 2000 m
■ Humidity: Maximum temperature is +40℃, air relative humidity of not more than
50%, at a lower temperature allows a higher relative humidity. For example, 20℃,
when up to 90%, and occasionally due to temperature changes resulting from Gel
should take special measures
■ Pollution Level: 3
■ Installation Type: Ⅲ
■ Installation position: should be installed in the absence of a significant shake and
shock and vibration place
Install Location
97
CDC17 AC Contactor
Standard: IEC 60947-4-1
Overall Dimensions
CDC17-9~32
a
2- d
CDC17-40~95
3
d
Motor Control &
Protection
Type
Amax Bmax Cmax C1max C2max a
b
c
CDC17-9~12
45
68
77
109
133
35±0.21
59±0.28
4.5
CDC17-18
45
68
82
115
138
CDC17-25
56.5
79
91
124
149
40±0.21
66±0.43
4.5
CDC17-32
56.5
40±0.21
105±0.57
6.5
79
95
127
152
CDC17-40~65 75
127
115
145
170
CDC17-80~95 85
127
123
153
178
Note:C1max-Contactor+CDF4
98
C2max-Contactor+CDLA
CDC17 AC Contactor
Standard: IEC 60947-4-1
CDC17-115~150
CDC17-185~330
A
A1
B
C
C1
a1
a2
a3
b1
b2
Φ
b3
Φ1
CDC17-185
138
111
180
163
95
40
20
80
158
154
9
150
7
CDC17-225
138
111
199
163
95
48
25
80
172
172
11
150
7
CDC17-265, 330 171
144
207
201
119
48
25
96
180
180
11
166
11
Motor Control &
Protection
Type
CDC17-400~500
48
48
CDC17-630~1000
99
CDR17 Thermal Overload Relay
Standard: IEC 60947-4-1 IEC 60947-5-1
Function
CDR17 series thermal overload relay provide:
□ Protection of circuits and motors against overload
□ Protection of circuits and motors against phase loss
□ Motor starters installation in association with contactors
Order Information
Reference Description
CDR17
18
P15
Setting current Rated current
Model
Type
Rated
insulation
voltage
Ui V
CDR17-18 690
Range of current
setting A
Reference
Recommended
contactor
18
0.1~0.13~0.15
CDR1718P15
CDC17-9~18
0.12~0.16~0.18
CDR1718P18
CDC17-9~18
0.18~0.2~0.25
CDR1718P25
CDC17-9~18
0.25~0.32~0.36
CDR1718P36
CDC17-9~18
0.35~0.4~0.5
CDR1718P5
CDC17-9~18
0.5~0.6~0.7
CDR1718P7
CDC17-9~18
0.63~0.72~0.9
CDR1718P9
CDC17-9~18
0.9~1~1.2
CDR17181P2
CDC17-9~18
1.2~1.6~1.8
CDR17181P8
CDC17-9~18
1.8~2~2.5
CDR17182P5
CDC17-9~18
2.5~3.2~3.6
CDR17183P6
CDC17-9~18
3.5~4~4.8
CDR17184P8
CDC17-9~18
4.5~5~6.3
CDR17186P3
CDC17-9~18
5~6~7
CDR17187
CDC17-9~18
6.3~7.2~9
CDR17189
CDC17-9~18
9~10~12
CDR171812
CDC17-9~18
11~13~15
CDR171815
CDC17-9~18
14~16~18
CDR171818
CDC17-9~18
4.5~5~6.3
CDR17326P3
CDC17-25~32
5~6~7
CDR17327
CDC17-25~32
6.3~7.2~9
CDR17329
CDC17-25~32
9~10~12
CDR173212
CDC17-25~32
12~16~18
CDR173218
CDC17-25~32
18~20~25
CDR173225
CDC17-25~32
23~25~32
CDR173232
CDC17-25~32
Motor Control &
Protection
Frame size
rated current
CDR17-32 690
100
32
CDR17 Thermal Overload Relay
Standard: IEC 60947-4-1 IEC 60947-5-1
Order Information
Type
Rated
insulation
voltage
Ui V
CDR17-95 690
CDR17-185 690
Range of current
setting A
Reference
Recommended
contactor
95
9~10~12
CDR179512
CDC17-40~95
12~16~18
CDR179518
CDC17-40~95
18~20~25
CDR179525
CDC17-40~95
23~25~32
CDR179532
CDC17-40~95
30~36~40
CDR179540
CDC17-40~95
37~45~50
CDR179550
CDC17-40~95
48~55~65
CDR179565
CDC17-40~95
55~63~70
CDR179570
CDC17-40~95
63~70~80
CDR179580
CDC17-40~95
75~90~95
CDR179595
CDC17-40~95
37~45~50
CDR1718550
CDC17-115~185
48~55~65
CDR1718565
CDC17-115~185
55~63~70
CDR1718570
CDC17-115~185
63~70~80
CDR1718580
CDC17-115~185
75~90~95
CDR1718595
CDC17-115~185
90~100~115
CDR17185115
CDC17-115~185
105~115~135
CDR17185135
CDC17-115~185
120~135~150
CDR17185150
CDC17-115~185
130~150~160
CDR17185160
CDC17-185
150~160~185
CDR17185185
CDC17-185
185
101
Motor Control &
Protection
Frame size
rated current
CDR17 Thermal Overload Relay
Standard: IEC 60947-4-1 IEC 60947-5-1
Technical Data
Temperature compensation
-10℃~+55℃
Trip class10A
CDR17-18, 32, 95
CDR17-185
10
Rated insulation voltage Ui V
690V
Structure characteristics
Overload protection
Yes
Phase-failure protection
Yes
Manual reset
Yes
Automatic reset
Yes
Stop button
Yes
Test button
Yes
Trip direction
Yes
Tolerance on slope in any direction
±22.5°
Control circuit
Motor Control &
Protection
102
Utilization category
AC-15
Rated frequency Hz
50
50
50
Rated insulation voltage Ui V
690
690
690
690
Rated operational voltage Ue V
220/230
380/400 660/690
Rated operational current Ie A
1.64/1.57 0.95/0.9 0.55/0.52
0.23/0.22
Conventional free air thermal current Ith A
6
6
6
Contact circuit
Utilization category
AC-15
DC-13
Rated frequency Hz
50
Rated insulation voltage Ui V
690
690
Rated operational voltage Ue V
660/690
220/230
Rated operational current Ie A
6
6
Conventional free air thermal current Ith A
6
6
DC-13
6
220/230
CDR17 Thermal Overload Relay
Standard: IEC 60947-4-1 IEC 60947-5-1
Trip Characteristic
Trip time
Multiples of
Sequence
setting current
Trip class 10A
Initial condition
Ambient
temperature
>2h
From cold state
+20℃
<2h
From hot
state(immediately
following
sequence 1 test)
Trip class 10
Limits of operation of relays when energized on all poles
1
1.05
2
>2h
1.2
<2h
3
1.5
<2min
<4min
From hot
state(immediately
following
sequence 1 test)
4
7.2
2s<Tp≤10s
4s<Tp≤10s
From cold state
+20℃
>2h
From cold state
+20℃
<2h
From hot
state(immediately
following
sequence 1 test)
Limits of operation when energized on two poles
1
1.0
2
1.15
0.9
0
>2h
<2h
Motor Control &
Protection
Any two The thirdpoles
pole
Accessories
Base
Name
Thermal Overload Relay
Reference
CDR17-18
CDR1718J
CDR17-32
CDR1732J
CDR17-95
CDR1795J
103
CDR17 Thermal Overload Relay
Standard: IEC 60947-4-1 IEC 60947-5-1
Work conditions
Ambient temperature: -10℃~+55℃, daily average temperature ≤35℃
Altitude: ≤2000m
Humidity: The relative humidity of the installtion position shall not exceed 50% when
the maximum temperature reaches +40℃. But there can be higher relative humidity
under lower temperature. For example, it can reach 90% when temperature is at
20℃. Special measures should be taken against condensation occuring on product
surface caused by temperature change
Pollution class: 3
Installation conditions
Installation Type: Ⅲ
Installation position: Unobvious shake and impact shock is necessary. Vertically
mounting. Tolerance on slope in any direction shall not exceed 22.5°
22.5
22.5
Motor Control &
Protection
360°
Wire Connection Picture
FU-Fuse
KM-Contactor
FR-Relay
SB1-Stop Button
SB2-Start Button
104
CDR17 Thermal Overload Relay
Standard: IEC 60947-4-1 IEC 60947-5-1
Overall Dimensions
CDR17-18
■
CDR17-32
■
CDR17-95
■
CDR17-185
Motor Control &
Protection
■
105
CJX2 AC Contactor
Standard: IEC 60947-4-1
Function
CJX2 AC contactors provide:
□ Remote make & break of circuits
□ Frequent start and stop of motors
Order Information
Rated current(A)
Motor P(kW) 380V
5.5
Auxiliary contact
NO
9
7.5
12
10
18
15
25
18.5
32
Reference
NC
Motor Control &
Protection
1
0
CJX2910*·
0
1
CJX2901*·
1
0
CJX21210*·
0
1
CJX21201*·
1
0
CJX21810*·
0
1
CJX21801*·
1
0
CJX22510*·
0
1
CJX22501*·
1
0
CJX23210*·
0
1
CJX23201*·
30
40
1
1
CJX24011*·
33
50
1
1
CJX25011*·
37
65
1
1
CJX26511*·
45
80
1
1
CJX28011*·
55
95
1
1
CJX29511*·
Reference Description
CJX2
9
10
*
·
Coil Frequency
Coil Voltage
Auxiliary contact
Rate current
Model
Coil voltage code
coil voltage
*
36V
110V
127V
220V
380V
400V
C
F
S
M
Q
V
Coil frequency code
coil frequency
·
106
50Hz
5
60Hz
6
CJX2 AC Contactor
Standard: IEC 60947-4-1
Technical Data
Model
CJX2-09 CJX2-12 CJX2-18 CJX2-25 CJX2-32 CJX2-40 CJX2-50 CJX2-65 CJX2-80 CJX2-95
Main circuit characteristics
Rated operational voltage
V
380, 660
Rated insulation voltage
V
690
Conventional thermal current
A
25
25
32
40
50
60
80
80
125
125
12
18
25
32
40
50
65
80
95
39
42
Rated operational
380V, AC-3 A
9
current
380V, AC-4 A
3.5
5
7.7
18
21
34
49
55
660V, AC-3 A
6.6
8.9
12
8.5
12
18.5
24
28
37
44
660V, AC-4 A
1.5
2
3.8
4.4
7.5
9
12
14
17.3
21.3
Power of controlled 220V, AC-3 kW
4
5.5
7.5
11
15
18.5
22
30
37
45
3-phase cage
380V, AC-3 kW
5.5
7.5
10
15
18.5
30
33
37
45
55
motor
660V, AC-4 kW
2.2
3
4
5.5
7.5
11
15
18.5
22
25
4
AC-3 ×10 operations 100
80
80
60
4
AC-4 ×10 operations 20
20
15
10
Electric durabilities
4
Mechanical durabilities
Operating rate
×10 cycles
1000
800
800
600
AC-3 cycles/h
1200
600
600
600
AC-4 cycles/h
300
300
300
300
RT16-20 RT16-20 RT16-32 RT16-40 RT16-50 RT16-63 RT16-80 RT16-80 RT16-100 RT16-125
Cable connection cross section
mm2
1.5
1.5
2.5
4
6
10
16
16
25
35
Coil
Coil voltage(Us)
V
AC36,110,127,220,380,400
Operational voltage
V
85%~110%Us
Drop-out voltage
V
20%~75%Us
Inrush
VA
70
110
200
Sealed
VA
8
11
20
Heat dissipation
W
1.8~2.7
3~4
6~10
Front mount
F4
Side mount
FC6
Accessories
Auxiliary contact
Time-delay block
Front mount
SK4
FR632H
Mechanical Interlock
Rated conventional thermal current
A
10
Rated operational voltage AC
V
380
DC
V
220
Rated control capacity
AC-15 VA
360
DC-13 W
33
FR695HX
107
Motor Control &
Protection
Matched Fuse
CJX2 AC Contactor
Standard: IEC 60947-4-1
CJX2 Contactor Accessories
Mechanical interlocking module
Top of auxiliary contact
Side auxiliary contact
Air delay head
Thermal overload relays
Motor Control &
Protection
Contactor
9
Top of
auxiliary
contact
Side
auxiliary
contact
Air
delay
head
Mechanical
interlocking
module
Thermal
overload
relays
108
12
18
25
32
40
50
2 Poles:F411,F402,F420
4 Poles: F404,F413,F422,F431,F440
2 Poles: FC611, FC602, FC620
Making time-delay: SK420,SK422,SK424
Breaking time-delay: SK430,SK432,SK434
9-32A: FR632H
40-95A: FR695HX
JRS1D-25
0.1-0.16A
...
17-25A
JRS1D-36
23-32A
30-40A
JRS1D-93
23-32A
...
80-93A
65
80
95
CJX2 AC Contactor
Standard: IEC 60947-4-1
Accessories
F4 Top of auxiliary contact
Pole
2P
4P
Contact
Wiring diagram
Reference
NC
1
1
F411
0
2
F402
2
0
F420
0
4
F404
1
3
F413
2
2
F422
3
1
F431
4
0
F440
Motor Control &
Protection
NO
SK4 Air delay head
Delay Type
Wiring diagram
Making timedelay
Breaking
time-delay
Delay Range
Reference
0.1-3S
SK420
0.1-30S
SK422
10-180S
SK424
0.1-3S
SK430
0.1-30S
SK432
10-180S
SK434
FC6 Side auxiliary contact
Pole
Contact
NO
NC
0
2
Wiring diagram
Reference
51 61
2P
1
2
FC602
52
62
53
61
54
62
53
63
FC611
1
FC620
0
54
64
109
CJX2 AC Contactor
Standard: IEC 60947-4-1
Accessories
Mechanical interlocking module
Contactor Specifications
Reference
CJX2-9~32
FR632H
CJX2-40~95
FR695HX
Working Conditions
Ambient temperature:-5℃~+40℃, the daily average temperature ≤ 35℃
Altitude: ≤ 2000 m
■ Humidity: Maximum temperature is +40℃, air relative humidity of not more than
50%, at a lower temperature allows a higher relative humidity. For example, 20℃,
when up to 90%, and occasionally due to temperature changes resulting from Gel
should take special measures
■ Pollution Level: 3
■ Installation Type: Ⅲ
■ Installation position: should be installed in the absence of a significant shake and
shock and vibration place
■
■
Motor Control &
Protection
Install Location
110
CJX2 AC Contactor
Standard: IEC 60947-4-1
Overall Dimensions
Unit:mm
CJX2-09~32
CJX2-40~95
Motor Control &
Protection
Product Type
Amax
Bmax
Cmax
C1max
C2max
a
b
d
CJX2-09~12
47
76
82
115
115
35
50/60
4.5
CJX2-18
47
76
87
120
120
CJX2-25
57
86
97
130
130
40
50/60
4.5
CJX2-32
57
86
102
135
135
CJX2-40~65
77
129
116
149
149
40
100/110
6.5
CJX2-80~95
127
87
160
160
129
Note: C1max is auxiliary contact group +F4 C2max is air-delay contact+SK4
111
JRS1D Thermal Overload Relay
Standard: IEC 60947-4-1 IEC 60947-5-1
Function
JRS1D relay provide:
□ Protect motor and circuit
□ Possess overload and phase failure protection functions.
Order Information
Reference Description
JRS1D
25
P16
Setting current Rated current
Model
Current
setting(A)
Reference
Recommended
contactor
Recommended
fuse
25
0.1~0.16
JRS1D25P16
CJX2-09~32
RT16-4
0.16~0.25
JRS1D25P25
CJX2-09~32
RT16-4
0.25~0.4
JRS1D25P4
CJX2-09~32
RT16-4
0.4~0.63
JRS1D25P63
CJX2-09~32
RT16-4
0.63~1
JRS1D251
CJX2-09~32
RT16-4
1~1.6
JRS1D251P6
CJX2-09~32
RT16-4
1.6~2.5
JRS1D252P5
CJX2-09~32
RT16-6
2.5~4
JRS1D254
CJX2-09~32
RT16-10
4~6
JRS1D256
CJX2-09~32
RT16-16
5.5~8
JRS1D258
CJX2-09~32
RT16-20
7~10
JRS1D2510
CJX2-09~32
RT16-20
9~13
JRS1D2513
CJX2-12~32
RT16-25
12~18
JRS1D2518
CJX2-18~32
RT16-35
17~25
JRS1D2525
CJX2-25~32
RT16-50
23~32
JRS1D3632
CJX2-25~32
RT16-63
30~40
JRS1D3640
CJX2-32
RT16-80
23~32
JRS1D9332
CJX2-40~95
RT16-63
30~40
JRS1D9340
CJX2-40~95
RT16-80
37~50
JRS1D9350
CJX2-50~95
RT16-100
48~65
JRS1D9365
CJX2-50~95
RT16-100
55~70
JRS1D9370
CJX2-65~95
RT16-125
63~80
JRS1D9380
CJX2-80~95
RT16-125
80~93
JRS1D9393
CJX2-95
RT16-160
Motor Control &
Protection
Frame size
rated current(A)
36
93
112
JRS1D Thermal Overload Relay
Standard: IEC 60947-4-1 IEC 60947-5-1
Technical Data
Temperature compensation
-5℃~+40℃
Trip class
10A
JRS1D-25, 36
10
JRS1D-93
660V
Structure characteristics
Overload protection
Yes
Phase-failure protection
Yes
Manual reset
Yes
Automatic reset
Yes
Stop button
Yes
Test button
Yes
Trip direction
Yes
Tolerance on slope in any direction
±5°
Auxiliary circuit
Utilization category
AC-15
Rated frequency Hz
50
50
50
Rated insulation voltage Ui V
500
500
500
Rated operational voltage Ue V
220
380
220
Rated operational current Ie A
Motor Control &
Protection
Rated insulation voltage Ui V
DC-13
1.64
0.95
0.15
Conventional free air thermal current I th A
NO
5
5
5
NC
5
5
5
113
JRS1D Thermal Overload Relay
Standard: IEC 60947-4-1 IEC 60947-5-1
Accessories
Thermal Overload Relay
Reference
JRS1D-25
JRS1D25J
JRS1D-36
JRS1D36J
JRS1D-93
JRS1D93J
Trip Characteristic
Sequence
Multiples of
setting current
Trip time
Initial condition
Ambient
temperature
>2h
From cold state
+20℃
<2h
From hot
state(immediately
following
sequence 1 test)
Trip class
Trip class 10
10A
Limits of operation of relays when energized on all poles
1
Motor Control &
Protection
2
1.05
>2h
1.2
<2h
3
1.5
<2min
<4min
From hot
state(immediately
following
sequence 1 test)
4
7.2
2s<
Tp≤10s
4s<Tp≤10s
From cold state
+20℃
>2h
From cold state
+20℃
<2h
From hot
state(immediately
following
sequence 1 test)
Limits of operation when energized on two poles
Any two The thirdpoles
pole
1
2
114
1.0
1.15
0.9
0
>2h
<2h
JRS1D Thermal Overload Relay
Standard: IEC 60947-4-1 IEC 60947-5-1
Work Conditions
Ambient temperature: -5℃~+40℃, daily average temperature ≤35℃
Altitude: ≤2000m
Humidity:The relative humidity of the installtion position shall not exceed 50% when the maximum
temperature reaches +40℃. But there can be higher relative humidity under lower temperature.
For example, it can reach 90% when temperature is at 20℃. Special measures should be taken
against condensation occuring on product surface caused by temperature change
Pollution class: 3
Installation Conditions
�c
�c
Installation Type: Ⅲ
Installation position: Unobvious shake and impact shock is necessary. Vertically
�cmounting.
Tolerance on slope in any direction shall not exceed 5°
5°
5°
360°
Motor Control &
Protection
�c
Wire Connection Picture
FU-Fuse
KM-Contactor
FR-Relay
SB1-Stop Button
SB2-Start Button
115
JRS1D Thermal Overload Relay
Standard: IEC 60947-4-1 IEC 60947-5-1
Overall Dimensions
Unit: mm
JRS1D-25 / Z
JRS1D-36 / Z
Motor Control &
Protection
JRS1D-93 / Z
116
CJX2-F AC Contactor
Standard: IEC 60947-4-1
Function
CJX2-F AC contactors provide:
□ Remote make & break of circuits
□ Frequent start and stop of motors
Order Information
Motor P(kW) 380V
Rated current (A)
Reference
55
115
CJX2F115*
75
150
CJX2F150*
90
185
CJX2F185*
110
225
CJX2F225*
132
265
CJX2F265*
160
330
CJX2F330*
200
400
CJX2F400*
250
500
CJX2F500*
335
630
CJX2F630*
CJX2-F
9
10
Motor Control &
Protection
Reference Description
*
Coil Frequency
Coil Voltage
Auxiliary contact
Rate current
Model
Coil voltage code
coil voltage
36V
110V
220V
380V
400V
*
C
F
M
Q
V
Coil frequency code
coil frequency
·
50Hz
5
60Hz
6
117
CJX2-F AC Contactor
Standard: IEC 60947-4-1
Technical Data
Model
CJX2-F115 CJX2-F150 CJX2-F185 CJX2-F225 CJX2-F265 CJX2-F330 CJX2-F400 CJX2-F500 CJX2-F630
Main circuit characteristics
Rated operational voltage
V
1000
Rated insulation voltage
V
380,660
Rated conventional thermal current
A
200
200
275
275
315
380
450
630
800
Rated operational 380V, AC-3
A
115
150
185
225
265
330
400
500
630
current
380V, AC-4
A
52
60
79
85
105
117
138
147
188
660V, AC-3
A
86
108
118
137
170
235
303
353
462
660V, AC-4
A
49
61
69
82
98
118
135
145
170
Power of controlled 380V, AC-3
kW
55
75
90
110
132
160
200
250
335
3-phase cage motor 380V, AC-4
kW
25
30
40
45
55
63
72
80
100
660V, AC-3
kW
80
100
110
129
160
220
280
335
450
660V, AC-4
kW
45
55
63
75
90
110
129
140
160
Mechanical durabilities
×104 cycles 1000
1000
600
600
600
600
600
600
600
Electric durabilities
×104 operations 120
120
100
100
80
80
80
80
80
AC-3
cycles/h
600
600
600
600
600
600
300
300
300
AC-4
cycles/h
120
120
120
120
120
120
120
120
120
Operating rate
Motor Control &
Protection
Matched Fuse
Cable
cooper
RT16-250 RT16-355 RT16-425 RT16-500 RT16-630 RT16-800 RT16-800 RT17-1000 RT17-1250
number of Piece
2
connection conductor cross section mm
cooper bar number of Piece
dimension
1
1
1
1
1
1
2
2
2
95
95
150
150
185
240
150
185
240
/
/
/
/
/
/
2
2
2
/
/
/
/
/
/
30×5
40×5
50×5
Coil
Rated voltage power control(Us) V
AC36,110,220,380,400
Operational voltage
V
85%~110%Us
Drop-out voltage
V
20%~75%Us
Inrush
VA
550
550
800
800
1200
1200
1200
1250
1650
Sealed
VA
45
45
55
55
13
13
20
24
22
Heat dissipation
W
16
16
24
24
12
12
14
18
20
Rated conventional thermal current A
10
Auxliary contact
Rated operational
AC
V
380
voltage
DC
V
220
Rated control capacity
AC-15 VA
360
DC-13 W
33
118
CJX2-F AC Contactor
Standard: IEC 60947-4-1
CJX2-F Contactor Accessories
Top of auxiliary contact
Air delay head
Thermal overload relays
Motor Control &
Protection
Contactor
115
Top of
auxiliary
contact
Air
delay
head
Thermal
overload
relays
150
185
225
265
330
400
500
630
2 Poles:F411,F402,F420
4 Poles: F404,F413,F422,F431,F440
Making time-delay : SK420,SK422,SK424
Breaking time-delay : SK430,SK432,SK434
JRS2-180
55-88A
...
150-180A
JRS2-400
80-125A
...
250-400A
JRS2-630
320-500A
400-630A
119
CJX2-F AC Contactor
Standard: IEC 60947-4-1
Accessories
F4 Top of auxiliary contact
Pole
2P
4P
Contact
Wiring diagram
Reference
Motor Control &
Protection
NO
NC
1
1
F411
0
2
F402
2
0
F420
0
4
F404
1
3
F413
2
2
F422
3
1
F431
4
0
F440
SK4 Air delay head
Delay Type
Making timedelay
Breaking
time-delay
120
Wiring diagram
Delay Range
Reference
0.1-3S
SK420
0.1-30S
SK422
10-180S
SK424
0.1-3S
SK430
0.1-30S
SK432
10-180S
SK434
CJX2-F AC Contactor
Standard: IEC 60947-4-1
Working Conditions
Ambient temperature:-5℃~+40℃, the daily average temperature ≤ 35℃
Altitude: ≤ 2000 m
■ Humidity: Maximum temperature is +40℃, air relative humidity of not more than
50%, at a lower temperature allows a higher relative humidity. For example, 20℃,
when up to 90%, and occasionally due to temperature changes resulting from Gel
should take special measures
■ Pollution Level: 3
■ Installation Type: Ⅲ
■ Installation position: should be installed in the absence of a significant shake and
shock and vibration place
■
■
Install Location
Motor Control &
Protection
121
CJX2-F AC Contactor
Standard: IEC 60947-4-1
Overall Dimensions
Unit: mm
CJX2-F115~330
CJX2-F400~500
Motor Control &
Protection
CJX2-F630
Model
Amax Bmax Cmax P
S
F
M
H
L
X1
X1
Ga Ha
(200~500v) (600~1000v)
122
CJX2-F115 167
163
172
37
20
M6
131
147
124
107
10
15
80
110~1120
CJX2-F150 167
171
172
40
20
M8
131
150
124
107
10
15
80
110~1120
CJX2-F185 171
174
183
40
20
M8
131
154
127
103.5 10
15
80
110~1120
CJX2-F225 171
197
183
48
25
M10
131
172
127
103.5 10
15
80
110~1120
CJX2-F265 202
203
215
48
25
M10
147
178
147
141
10
15
96
110~1120
CJX2-F330 213
206
220
48
25
M10
147
181
158
145
10
15
96
110~1120
CJX2-F400 213
206
220
48
25
M10
146
181
158
145
15
20
80
170~1180
CJX2-F500 233
238
233
55
30
M10
150
208
172
146
15
20
80
170~1180
CJX2-F630 309
304
256
80
40
M12
181
264
202
155
20
30
180 170~1180
JRS2 Thermal Overload Relay
Standard: IEC 60947-4-1 IEC 60947-5-1
Function
JRS2 relay provide:
□ Protect motor and circuit
□ Possess overload and phase failure protection functions.
Order Information
Reference Description
JRS2
12P5
P16
F:Installed independently
Setting current
Rated current
Model
Current setting(A)
Reference
Recommended
fuse
180
55~88
JRS218088F
RT16 -125
63~90
JRS218090F
RT16 -125
80~110
JRS2180110F
RT16 -200
90~120
JRS2180120F
RT16 -200
110~135
JRS2180135F
RT16 -200
120~150
JRS2180150F
RT16 -200
135~160
JRS2180160F
RT16 -250
150~180
JRS2180180F
RT16 -250
80~125
JRS2400125F
RT16 -200
125~200
JRS2400200F
RT16 -400
160~250
JRS2400250F
RT16 -400
200~320
JRS2400320F
RT16 -500
250~400
JRS2400400F
RT16 -500
320~500
JRS2630500F
RT16 -630
400~630
JRS2630630F
RT16 -630
400
630
Motor Control &
Protection
Frame size rated
current( A )
123
JRS2 Thermal Overload Relay
Standard: IEC 60947-4-1 IEC 60947-5-1
Technical Data
Temperature compensation
-5℃~+40℃
Trip class 10A
JRS2-180
10
JRS2-400, 630
Rated insulation voltage Ui V
660V
Structure characteristics
Motor Control &
Protection
Overload protection
Yes
Phase-failure protection
Yes
Manual reset
Yes
Automatic reset
Yes
Stop button
Yes
Test button
Yes
Trip direction
Yes
Tolerance on slope in any direction
±5°
Auxiliary circuit
124
DC-13
Utilization category
AC-15
Rated frequency Hz
50
50
50
Rated insulation voltage Ui V
380
380
500
Rated operational voltage Ue V
220
380
220
Rated operational current Ie A
1.64
0.95
0.16
Conventional free
NO
5
5
5
NC
5
5
5
JRS2 Thermal Overload Relay
Standard: IEC 60947-4-1 IEC 60947-5-1
Trip Characteristic
Multiples of
Sequence
setting current
Trip time
Initial condition
Trip class Trip
10A
class 10
Ambient
temperature
Limits of operation of relays when energized on all poles
1
1.05
>2h
>2h
From cold state
+20℃
2
1.2
<2h
<2h
From hot state(immediately
following sequence 1 test)
3
1.5
<2min
<4min
From hot state(immediately
following sequence 1 test)
4
7.2
2s<
Tp≤10s
4s<
Tp≤10s
From cold state
+20℃
+20℃
Motor Control &
Protection
Limits of operation when energized on two poles
Any two The thirdpoles
pole
1
1.0
0.9
>2h
>2h
From cold state
2
1.15
0
<2h
<2h
From hot state(immediately
following sequence 1 test)
125
JRS2 Thermal Overload Relay
Standard: IEC 60947-4-1 IEC 60947-5-1
Work Conditions
Ambient temperature: -5℃~+40℃, daily average temperature ≤35℃
Altitude: ≤2000m
Humidity: The relative humidity of the installtion position shall not exceed 50%
when the maximum temperature reaches +40℃. But there can be higher
relative humidity under lower temperature. For example, it can reach 90% when
temperature is at 20℃. Special measures should be taken against condensation
occuring on product surface caused by temperature change
Pollution class: 3
Installation Conditions
Installation Type: Ⅲ
Installation position: Unobvious shake and impact shock is necessary. Vertically
mounting. Tolerance on slope in any direction shall not exceed 5°
5°
5°
Motor Control &
Protection
360°
Wire Connection Picture
FU-Fuse
KM-Contactor
FR-Relay
SB1-Stop Button
SB2-Start Button
126
JRS2 Thermal Overload Relay
Standard: IEC 60947-4-1 IEC 60947-5-1
Overall Dimensions
JRS2-180/F
■
JRS2-400~630/F
Motor Control &
Protection
■
25x4
50
10.5
70
146
171
50
Unit: mm
127
CDC9 Switching Capacitor Contactor
Standard: IEC 60947-4-1 IEC 60947-5-1
Function
CDC9 switching capacitor contactors provide:
□ Switch three-phase unipolar or multipolar capacitor group,to improve their power factor
□ Reduce the current closing of the impact of capacitor
Order Information
Auxiliary contact
Rated current(A)
25
32
43
Motor Control &
Protection
63
95
Reference
NO
NC
1
1
CDC92511*·
2
0
CDC92520*·
0
2
CDC92502*·
1
1
CDC93211*·
2
0
CDC93220*·
0
2
CDC93202*·
1
1
CDC94311*·
2
0
CDC94320*·
0
2
CDC94302*·
1
2
CDC96312*·
2
1
CDC96321*·
1
2
CDC99512*·
2
1
CDC99521*·
Reference Description
CDC9
9
10
*
·
Coil Frequency
Coil Voltage
Auxiliary contact
Rate current
Model
Coil voltage code
coil voltage
*
36V
110V
127V
220V
380V
400V
C
F
S
M
Q
V
Coil frequency code
coil frequency
·
128
50Hz
5
60Hz
6
CDC9 Switching Capacitor Contactor
Standard: IEC 60947-4-1 IEC 60947-5-1
Technical Data
Model
CDC9-25
CDC9-32
CDC9-43
CDC9-63
CDC9-95
Main circuit
Rated operational voltage
V
380
Rated insulation voltage
V
500
Controlled capacitor rate capacity 380V, AC-6b
A
17
23
29
43
63
Controlled capacitor rate capacity 220V, AC-6b
Kvar
6
9
10
15
22.5
380V, AC-6b
Kvar
12
18
20
30
45
A
25
32
43
63
95
Rate conventional thermal current
Control inrush current capacity
≤20ln
Mechanical life
×104 operations
100
Electric life
380V, AC-6b
×104 operations
10
Operating frequency
380V, AC-6b
operations/h
300
mm2
4
Cable connection cross section
400
120
of copper conductor
Coil
V
AC36,110,127,220,380,400
Operational voltage
V
85%~110%Us
Drop-out voltage
V
20%~75%Us
A
10
Motor Control &
Protection
Coil voltage(Us)
Auxiliary contact
Rate conventional thermal current
Minimum load can be connected
6V×10mA
129
CDC9 Switching Capacitor Contactor
Standard: IEC 60947-4-1 IEC 60947-5-1
Working Conditions
Ambient temperature:-5℃~+40℃, the daily average temperature ≤ 35℃
≤ 2000 m
■ Humidity: Maximum temperature is +40℃, air relative humidity of not more than
50%, at a lower temperature allows a higher relative humidity. For example, 20℃,
when up to 90%, and occasionally due to temperature changes resulting from Gel
should take special measures
■ Pollution Level: 3
■ Installation Type: Ⅲ
■ Installation position: should be installed in the absence of a significant shake and
shock and vibration place
■
■ Altitude:
Install Location
Motor Control &
Protection
130
CDCK8 Air Condition Contactor
Standard: IEC 60947-4-1 IEC 60947-5-1
Function
CDCK8 air condition contactor provide:
□ Remote make & break of circuits
□ Frequent start and stop of motors
Order Information
Rated current(A)
Pole
25
1P
32
Auxiliary contact
1P
Reference
NO
NC
0
1
CDCK825101*·
0
0
CDCK825100*·
0
1
CDCK832101*·
0
0
CDCK832100*·
45
1P
0
0
CDCK845100*·
25
2P
0
0
CDCK825200*·
32
2P
0
0
CDCK832200*·
Motor Control &
Protection
Reference Description
CDCK8
25
1
10
*
·
Coil Frequency
Coil Voltage
Auxiliary contact
Pole
Rate current
Model
Coil voltage code
Coil voltage
*
36V
110V
220V
C
F
M
50Hz
5
60Hz
6
Coil frequency code
Coil frequency
·
131
CDCK8 Air Condition Contactor
Standard: IEC 60947-4-1 IEC 60947-5-1
Technical Data
Model
CDCK8-25
CDCK8-32
CDCK8-45
Main circuit characteristics
Rate insulation voltage
V
690
Rated voltage shock tolerance
kV
4
Rated operational voltage
V
220
A
32
40
50
A
25
32
45
kW(Hp)
2.5(3)
3.2(4)
4.5(5)
x104 operations
100
Rate conventional thermal current
Rate operational current
Power of controlled
AC-8b
220V, AC-8b
single-phase motor
Mechanical life
Electric life
AC-8b
x104 operations
8
Operating frequency
AC-8b
operations/h
300
Short time withstand current
10S
A
8le
Matched fuse
Motor Control &
Protection
RT16-40
RT16-50
RT16-63
Connecting line
mm2
6
10
16
Coil
Coil voltage(Us)
V
AC36,110,220
V
70%~110%Us
V
20%~60%Us
VA
36
VA
4
Rate conventional thermal current
A
5
Rated operational voltage V
V
220
VA
100
Operational voltage
Drop-out voltage
Inrush
Sealed
Auxiliary contact
Control capability
132
AC-1
CDCK8 Air Condition Contactor
Standard: IEC 60947-4-1 IEC 60947-5-1
Working Conditions
Ambient temperature:-5℃~+40℃, the daily average temperature ≤ 35℃
Altitude: ≤ 2000 m
■ Humidity: Maximum temperature is +40℃, air relative humidity of not more than
50%, at a lower temperature allows a higher relative humidity. For example, 20℃,
when up to 90%, and occasionally due to temperature changes resulting from Gel
should take special measures
■ Pollution Level: 3
■ Installation Type: Ⅲ
■ Installation position: should be installed in the absence of a significant shake and
shock and vibration place
■
■
Install Location
Motor Control &
Protection
133
CDCK8 Air Condition Contactor
Standard: IEC 60947-4-1 IEC 60947-5-1
Overall Dimensions
Unit:mm
Motor Control &
Protection
134
Product type
Pole
Amax
Bmax
CDCK8-25,32
1P
70
62
CDCK8-25/01,32/01
1P
70
69
CDCK8-25,32
2P
86
61.5
CDCK8-45
1P
85
67
CDZ17 Contactor Relay
Standard: IEC 60947-5-1
Function
CDZ17 contactor relays provide:
□ Remote make & break of circuits
□ Start, stop and control of small capacity motors
□ Boost signals, interlock electric, transfer signals or control various kinds of magnetic
coils
Order Information
Contact blocks
Rated current(A)
6
9
9
NC
1
3
CDZ17613*
2
2
CDZ17622*
3
1
CDZ17631*
4
0
CDZ17640*
0
4
CDZ17604*
1
3
CDZ17913*
2
2
CDZ17922*
3
1
CDZ17931*
4
0
CDZ17940*
0
4
CDZ17904*
4
4
CDZ17644*
5
3
CDZ17653*
6
2
CDZ17662*
7
1
CDZ17671*
8
0
CDZ17680*
4
4
CDZ17944*
5
3
CDZ17953*
6
2
CDZ17962*
7
1
CDZ17971*
8
0
CDZ17980*
Motor Control &
Protection
6
Reference
NO
Coil voltage code
Coil voltage
24V
36V
48V
110V
220V
380V
400V
440V
*
B
C
E
F
M
Q
V
X
Coil power supply
Coil power supply
DC
AC
Z
Default
Reference Description
CDZ17
9
13
M
Default: AC
Z:DC
Coil voltage
Contact blocks
Rated current
Model
135
CDZ17 Contactor Relay
Standard: IEC 60947-5-1
Technical Data
6A
Model
9A
24
48
110
220
440
24
48
110
220
440
4
2.5
1
0.5
0.2
6
3.5
1.5
0.6
0.3
36
110
220/230 380/400 690
36
110
220/230 380/400
Rated operational current A
6
6
6
9
9
9
Contact assemble
Single
Rated operational voltage V
DC-13
Rated operational voltage A
Rated operational current V
AC-15
4
1.5
Double
NO
NC
NO
NC
1
3
4
4
2
2
5
3
3
1
6
2
4
0
7
1
0
4
8
0
Motor Control &
Protection
Rated insulation voltage V
690
Rated impulse withstand voltage V
8000
Rated conventional thermal current A
16
Minimum load can be connected
12V
Electric durabilities(x104 operations)
100
Mechanical durabilities(x104 cycles)
1000
Operating rate(cycles/h)
3000(AC)
Matched Fuse
RT16-20
Cross Section of Cable mm2 (maximum)
2.5(X2)
10mA
1200(DC)
Coil
Coil voltage(Us) V
AC36, 110, 220, 380,400; DC24, 48, 110, 220, 440
Operational voltage V
80%~110%Us
Drop-out voltage V
20%~75%Us(AC)
Inrush VA
70(AC)
Sealed VA
8(AC)
Heat dissipation W
2.8(AC)
Weight
0.32(Single,AC)
0.36(double,AC)
0.52(Single,DC)
0.56(double,DC)
136
Kg
10%~75%Us(DC)
7(DC)
6.5(DC)
6
690
3
CDZ17 Contactor Relay
Standard: IEC 60947-5-1
Work Conditions
■ Ambient
temperature: -15℃~+50℃, daily average temperature ≤35℃
≤2000m
■ Humidity: The relative humidity of the installtion position shall not exceed 50%
when the maximum temperature reaches +50℃. But there can be higher
relative humidity under lower temperature. For example, it can reach 90% when
temperature is at 20℃. Special measures should be taken against condensation
occuring on product surface caused by temperature change
■ Pollution class: 3
■ Altitude:
Installation Conditions
■ Installation
Type: Ⅲ
position: Unobvious shake and impact shock is necessary. Vertically
mounting. Tolerance on slope in any direction shall not exceed 5°
■ Installation
25°
25°
Motor Control &
Protection
137
CDZ17 Contactor Relay
Standard: IEC 60947-5-1
Overall Dimensions
CDZ17-40, 31, 22, 13, 04
CDZ17-80, 71, 62, 53, 44
Motor Control &
Protection
CDZ17-40/Z, 31/Z, 22/Z, 13/Z, 04/Z
CDZ17-80/Z,71/Z,62/Z,53/Z,44/Z
138
Unit: mm
CDZ8 Miniature Relay
Function
Used to implement the conversion of intermediate control signals and low-power output, In the
field of industrial control, used in conjunction with contactors, relays, circuit breakers, etc.
Order Information
Poles
Rated Current
LED
Voltage Type
Reference
2
5A
L
AC
CDZ8052L*1
None
AC
CDZ8052*1
L
DC
CDZ8052L*Z1
None
DC
CDZ8052*Z1
Accessory
3
CDZ8PYF08AXXKH
5A
L
AC
CDZ8053L*1
None
AC
CDZ8053*1
L
DC
CDZ8053L*Z1
None
DC
CDZ8053*Z1
Accessroy
4
CDZ8PYF11AXXKH
3A
AC
CDZ8034L*1
AC
CDZ8034*1
L
DC
CDZ8034L*Z1
None
DC
CDZ8034*Z1
Accessory
CDZ8PYF14AXXKH
Rated voltage code
Rated voltage
6V
12V
24V
36V
48V
110V
127V
220V
230V
*
I
J
B
C
E
F
S
M
N
139
Motor Control &
Protection
L
None
CDZ8 Miniature Relay
Technical Data
Contact
Form
2Z
3Z
4Z
Capacity
5A
5A
3A
Nominal coil voltage
AC 6-220V
DC 6-220V
Resistance
≤50mΩ
Materials
Silver Alloy
Electrical life expectancy
≥105 times (1800 Ops/h)
Mechanical life expectancy
≥107 times (18000 Ops/h)
Type Description
LED
Operating voltage (25℃)
DC:≤ 75%Ue, AC:80%Ue
Release voltage (25℃)
DC:≥10%Ue, AC:30%Ue
Maximum voltage (25℃)
110%Ue
Coil consumption DC(W)
0.9
1.2
AC(VA)
Motor Control &
Protection
Operating time (Rated voltage)
≤20ms
Release time (Rated voltage)
≤20ms
Dielectric Strength
Between contacts
1300VAC/1min
Between
1500VAC/1min
contacts(different pole)
Between Contact and coil
1800VAC/1min
Ambient temperature
-25~+55℃
Humidity
35%~85%RH
Atmospheric pressure
86~106KPa
Shock resistance
10G(Sine half-wave pulse:11ms)
Vibration resistance
10~55Hz Double amplitude:1.0mm
Install model
Plug-in terminals
Weight
35g
Coil Specifications (25℃)
140
Rated voltage V.DC
6
12
24
36
Coil resistanceΩ(±10%)
40
160
600
1440 2600 11000
42000
Rated voltage V.AC
6
12
24
36
48
110
127
220
Coil resistance Ω(±10%)
11.5
40
160
370
600
3750
4100
14000
48
110
220
CDZ8 Miniature Relay
Accessories
Matched relay socket
Outline dimensions(mm)
CDZ8PYF08AXXKH
3Z
CDZ8PYF11AXXKH
4Z
CDZ8PYF14AXXKH
Wiring diagram
Motor Control &
Protection
2Z
Mount dimensions
141
CDZ8 Miniature Relay
Overall Dimensions
Unit: mm
CDZ8-2Z
■
CDZ8-3Z
■
CDZ8-4Z
Motor Control &
Protection
■
142
JSZ3 Series Electronic Time Relay
Standard: IEC 60947-5-1
Function
JSZ3 Series eletroms time relay provide
Rated AC frequency 50Hz & controlling voltage 400V or below.
Rated DC control power voltage 220V or below.
Be used as time-control component in the automatic controlling circuit, according to the scheduled time turn on or off the circuit.
Order Information
Relay mode
Rated working voltage
Relay after
120V
power-on
240V
Reference
A: 0.05-0.5s/5s/30s/3M
JSZ3AA120
B: 0.1-1s/10s/60s/6M
JSZ3AB120
C: 0.5-5s/50s/5M/30M
JSZ3AC120
D: 1-10s/100s/10M/60M
JSZ3AD120
E: 6s-60s/10M/60M/6h
JSZ3AE120
F: 0.2M-2M/20M/2h/12h
JSZ3AF120
G: 0.4M-4M/40M/4h/24h
JSZ3AG120
A: 0.05-0.5s/5s/30s/3M
JSZ3AA240
B: 0.1-1s/10s/60s/6M
JSZ3AB240
C: 0.5-5s/50s/5M/30M
JSZ3AC240
D: 1-10s/100s/10M/60M
JSZ3AD240
E: 6s-60s/10M/60M/6h
JSZ3AE240
F: 0.2M-2M/20M/2h/12h
JSZ3AF240
G: 0.4M-4M/40M/4h/24h
JSZ3AG240
A: 0.05-0.5s/5s/30s/3M
JSZ3AA400
B: 0.1-1s/10s/60s/6M
JSZ3AB400
C: 0.5-5s/50s/5M/30M
JSZ3AC400
D: 1-10s/100s/10M/60M
JSZ3AD400
E: 6s-60s/10M/60M/6h
JSZ3AE400
F: 0.2M-2M/20M/2h/12h
JSZ3AF400
G: 0.4M-4M/40M/4h/24h
JSZ3AG400
Motor Control &
Protection
400V
Relay time
143
JSZ3 Series Electronic Time Relay
Standard: IEC 60947-5-1
Order Information
Relay mode
Relay after
Rated working voltage
120V
power-off
240V
Motor Control &
Protection
400V
144
Relay time
Reference
1S: 0.1-1s
2S: 0.2-2s
3S: 0.3s-3s
5S: 0.5s-5s
6S: 0.6s-6s
10S: 1s-10s
20S: 2s-20s
30S: 3s-30s
60S: 6s-60s
100S: 10s-100s
180S: 18s-180s
4M: 0.4min-4min
5M: 0.5min-5min
6M: 0.6min-6min
10M: 1min-10min
20M: 2min-20min
30M: 3min-30min
1S: 0.1-1s
2S: 0.2-2s
3S: 0.3s-3s
5S: 0.5s-5s
6S: 0.6s-6s
10S: 1s-10s
20S: 2s-20s
30S: 3s-30s
60S: 6s-60s
100S: 10s-100s
180S: 18s-180s
4M: 0.4min-4min
5M: 0.5min-5min
6M: 0.6min-6min
10M: 1min-10min
20M: 2min-20min
30M: 3min-30min
1S: 0.1-1s
2S: 0.2-2s
3S: 0.3s-3s
5S: 0.5s-5s
6S: 0.6s-6s
10S: 1s-10s
20S: 2s-20s
30S: 3s-30s
60S: 6s-60s
100S: 10s-100s
180S: 18s-180s
4M: 0.4min-4min
5M: 0.5min-5min
6M: 0.6min-6min
10M: 1min-10min
20M: 2min-20min
30M: 3min-30min
JSZ3F1S120
JSZ3F2S120
JSZ3F3S120
JSZ3F5S120
JSZ3F6S120
JSZ3F10S120
JSZ3F20S120
JSZ3F30S120
JSZ3F60S120
JSZ3F100S120
JSZ3F180S120
JSZ3F4M120
JSZ3F5M120
JSZ3F6M120
JSZ3F10M120
JSZ3F20M120
JSZ3F30M120
JSZ3F1S240
JSZ3F2S240
JSZ3F3S240
JSZ3F5S240
JSZ3F6S240
JSZ3F10S240
JSZ3F20S240
JSZ3F30S240
JSZ3F60S240
JSZ3F100S240
JSZ3F180S240
JSZ3F4M240
JSZ3F5M240
JSZ3F6M240
JSZ3F10M240
JSZ3F20M240
JSZ3F30M240
JSZ3F1S400
JSZ3F2S400
JSZ3F3S400
JSZ3F5S400
JSZ3F6S400
JSZ3F10S400
JSZ3F20S400
JSZ3F30S400
JSZ3F60S400
JSZ3F100S400
JSZ3F180S400
JSZ3F4M400
JSZ3F5M400
JSZ3F6M400
JSZ3F10M400
JSZ3F20M400
JSZ3F30M400
JSZ3 Series Electronic Time Relay
Standard: IEC 60947-5-1
Technical Data
Condition
AC-15
400V/1.95A; 240V/1.5A; 120V/3.0A DC-13
250V/0.27A; 125V/0.55A Repetitive error
≤5%
Rated themal current
5A
Mechanical life
≥1×106 times
Electric life
≥1×105 times
Power loss
≤3W
Working mode
A: Relay after power-on
Reset mode
A:Power-off reset
F:External device reset
Contactor endurance
A:5A (Resistive)
F:1A(Resistive)
Relay time
JSZ3A: 0.05s-0.5s/5s/30s/3M,0.1s-1s/10s/60s/6M
0.5s-5s/50s/5M/30M,1s-10s/100s/10M/60M
F:Relay after power-off
6s-60s/10M/60M/6h,0.2M-2M/20M/2h/12h
0.4M-4M/40M/4h/24h JSZ3F: 0.1s-1s,0.2s-2s,0.3s-3s,0.5s-5s,0.6s-6s,1s10s,2s-20s,3s-30s,6s-60s,10s-100s,10s-120s,10s180s,0.4M-4M,0.5M-5M,0.6M-6M,1M-10M,2MTemp.
-5℃~+40℃
Install mode
Install mounted, Din rail mounted, Panel mounted
Motor Control &
Protection
20M,3M-30M
Overall Dimensions
Unit: mm
ELECTRIC
145
XJ9 Phase Failure And Sequence
Protection Relay
Standard: IEC 60947-5-1
Function
XJ9 phace failare and sequence proctection relay provide:
Rated AC frequency of 50Hz, rated control supply voltage AC 400V.
Phase failure and phase sequence protector.
Order Information
Function
Voltage
Reference
Phase failure
sequency protection
380V
400V
XJ9380
XJ9400
Technical Data
Standard
IEC 60947-5-1
Overvoltage protection
400-480V(adjustable), Reaction time: 1.5-4S(adjustable)
Undervoltage protection
320-400V(adjustabe). Reaction time: 2-9S(adjustable)
Phase failure & phase
Reaction time ≤2S
Wrong protect time
Motor Control &
Protection
Contactor mode
1 NO,1NC
Contactor endurance
5A Resistive
Power voltage
AC 400V
Mechanical lifetime
≥1×106 times
Electrical lifetime
≥1×105 times
Power loss
≤1W
Contactor capacity
AC400V×3
Overall Dimensions
Unit: mm
XJ9
35.5
83Max
91Max
24Max
146
Contents
Power Energy Management
Current Transformer
148-150
LMK Series
148
Current Transformer
151-163
Meter
DDS607
Single-phase Electronic Watt-hour Meter
152
DTS607
Three-phase Four-Wire Electronic Watt-hour Meter
154
DSS607
Three-phase Three-Wire Electronic Watt-hour Meter
157
72 Series
Panel Meter
160
96 Series
Panel Meter
162
164-167
1~5
KG316T
Digital Time Switch
165
KG316TD
Digital Time Switch
166
KG816 Series Digital Time Switch
167
Voltage Stabilizer
168-174
TND
Single-phase Full Automatic AC Voltage Stabilizer
169
SJW
Three-phase Full Automatic AC Voltage Stabilizer
171
SBW
Three-phase Compensation AC Voltage Stabilizer
173
Management
Power Energy
Digital Time Switch
147
LMK Series Current Transformer
Standard: IEC 60044-1
Function
LMK Series Current Transformer provide:
Measuring and transforming the high current to low current.
Order Information
Model
LMK-0.66-20
LMK-0.66-30
LMK-0.66-40
LMK-0.66-50
LMK-0.66-60
Power Energy
Management
LMK-0.66-80
LMK-0.66-100
LMK-0.66-120
148
Current ratio
(A)
30/5
50/5
75/5
100/5
100/5
150/5
200/5
100/5
200/5
250/5
300/5
250/5
300/5
400/5
500/5
300/5
400/5
500/5
600/5
750/5
800/5
1000/5
500/5
600/5
750/5
800/5
1000/5
1200/5
1500/5
600/5
750/5
800/5
1000/5
1200/5
1500/5
2000/5
2500/5
600/5
750/5
800/5
1000/5
1200/5
1500/5
2000/5
2500/5
3000/5
1500/5
2000/5
2500/5
3000/5
4000/5
5000/5
Class: 0.5
Maximum Voltage: 0.66KV
Rated Load
(VA)
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
10-3.75
10-3.75
10-3.75
10-3.75
5-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
15-3.75
15-3.75
20-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
15-3.75
15-3.75
20-3.75
20-3.75
15-3.75
15-3.75
20-3.75
20-3.75
25-3.75
25-3.75
Bar
(mm)
30×10
30×10
30×10
40×10
40×10
40×10
40×10
50×10
50×10
50×10
50×10
50×10
50×10
50×10
60×20
60×20
60×20
60×20
60×20
60×20
60×20
80×10 or 60×30
80×10 or 60×30
80×10 or 60×30
80×10 or 60×30
80×10 or 60×30
80×10 or 60×30
80×10 or 60×30
80×10 or 60×30
100×10 or 80×30
100×10 or 80×30
100×10 or 80×30
100×10 or 80×30
100×10 or 80×30
100×10 or 80×30
100×10 or 80×30
100×10 or 80×30
100×10 or 80×30
120×10 or 80×30
120×10 or 80×30
120×10 or 80×30
120×10 or 80×30
120×10 or 80×30
120×10 or 80×30
Diameter
(mm)
20
20
20
20
20
20
20
20
20
20
20
30
30
30
30
35
35
35
35
35
35
35
45
45
45
45
45
45
45
50
50
50
50
50
50
50
50
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
Number of Turns
Reference
through the core
5
3
2
2
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
LMKP63020
LMKP65020
LMKP67520
LMKP610020
LMKP610020
LMKP615020
LMKP620020
LMKP610030
LMKP620030
LMKP625030
LMKP630030
LMKP625040
LMKP630040
LMKP640040
LMKP650040
LMKP630050
LMKP640050
LMKP650050
LMKP660050
LMKP675050
LMKP680050
LMKP6100050
LMKP650060
LMKP660060
LMKP675060
LMKP680060
LMKP6100060
LMKP6120060
LMKP6150060
LMKP660080
LMKP675080
LMKP680080
LMKP6100080
LMKP6120080
LMKP6150080
LMKP6200080
LMKP6250080
LMKP6600100
LMKP6750100
LMKP6800100
LMKP61000100
LMKP61200100
LMKP61500100
LMKP62000100
LMKP62500100
LMKP63000100
LMKP61500120
LMKP62000120
LMKP62500120
LMKP63000120
LMKP64000120
LMKP65000120
LMK Series Current Transformer
Standard: IEC 60044-1
Order Information
Class: 1
Maximum Voltage: 0.66KV
Model
Current ratio Rated Load
(VA)
(A)
Bar
(mm)
LMK-0.66-20
30/5
50/5
75/5
100/5
150/5
200/5
100/5
200/5
250/5
300/5
250/5
300/5
400/5
500/5
600/5
300/5
400/5
500/5
600/5
750/5
800/5
1000/5
1200/5
500/5
600/5
750/5
800/5
1000/5
1200/5
1500/5
2000/5
600/5
750/5
800/5
1000/5
1200/5
1500/5
2000/5
2500/5
600/5
750/5
800/5
1000/5
1200/5
1500/5
2000/5
2500/5
3000/5
1500/5
2000/5
2500/5
3000/5
4000/5
5000/5
20
20
20
20
20
20
20
20
30×10
20
30×10
20
30×10
30
40×10
30
40×10
30
40×10
30
40×10
30
40×10
35
50×10
35
50×10
35
50×10
35
50×10
35
50×10
35
50×10
35
50×10
35
60×20
45
60×20
45
60×20
45
60×20
45
60×20
45
60×20
45
60×20
45
60×20
45
60×20
80×10 or 60×30 50
80×10 or 60×30 50
80×10 or 60×30 50
80×10 or 60×30 50
80×10 or 60×30 50
80×10 or 60×30 50
80×10 or 60×30 50
80×10 or 60×30 50
100×10 or 80×30 60
100×10 or 80×30 60
100×10 or 80×30 60
100×10 or 80×30 60
100×10 or 80×30 60
100×10 or 80×30 60
100×10 or 80×30 60
100×10 or 80×30 60
100×10 or 80×30 60
120×10 or 80×30 60
120×10 or 80×30 60
120×10 or 80×30 60
120×10 or 80×30 60
120×10 or 80×30 60
120×10 or 80×30 60
LMK-0.66-30
LMK-0.66-40
LMK-0.66-50
LMK-0.66-60
LMK-0.66-100
LMK-0.66-120
5
3
2
2
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
LMKP6P13020
LMKP6P15020
LMKP6P17520
LMKP6P110020
LMKP6P115020
LMKP6P120020
LMKP6P110030
LMKP6P120030
LMKP6P125030
LMKP6P130030
LMKP6P125040
LMKP6P130040
LMKP6P140040
LMKP6P150040
LMKP6P160040
LMKP6P130050
LMKP6P140050
LMKP6P150050
LMKP6P160050
LMKP6P175050
LMKP6P180050
LMKP6P1100050
LMKP6P1120050
LMKP6P150060
LMKP6P160060
LMKP6P175060
LMKP6P180060
LMKP6P1100060
LMKP6P1120060
LMKP6P1150060
LMKP6P1200060
LMKP6P160080
LMKP6P175080
LMKP6P180080
LMKP6P1100080
LMKP6P1120080
LMKP6P1150080
LMKP6P1200080
LMKP6P1250080
LMKP6P1600100
LMKP6P1750100
LMKP6P1800100
LMKP6P11000100
LMKP6P11200100
LMKP6P11500100
LMKP6P12000100
LMKP6P12500100
LMKP6P13000100
LMKP6P11500120
LMKP6P12000120
LMKP6P12500120
LMKP6P13000120
LMKP6P14000120
LMKP6P15000120
149
Management
Power Energy
LMK-0.66-80
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
10-3.75
5-3.75
5-3.75
5-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
5-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
15-3.75
15-3.75
20-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
15-3.75
15-3.75
20-3.75
20-3.75
15-3.75
15-3.75
20-3.75
20-3.75
25-3.75
25-3.75
Diameter Number of Turns Reference
through the core
(mm)
LMK Series Current Transformer
Standard: IEC 60044-1
Technical
Data
Primary current: 100A-5000A
Secondary approval: 5A, 1A
Maximum voltage: 0.66kV
Class: 0.5, 1.0, 3.0
Short time thermal current: Ith=100Ih
Rated security coefficient: FS<5
Standard: IEC 60044-1
Overall Dimensions
Unit: mm
Power Energy
Management
150
Model
H
W
D
LMK-0.66-20
87
68
42
LMK-0.66-30
79
60
37
LMK-0.66-40
99
75
40
LMK-0.66-50
99
82
40
LMK-0.66-60
126
102
40
LMK-0.66-80
118
125
40
LMK-0.66-100
136
170
40
LMK-0.66-120
136
190
41
Meter Overview
Watt-hour Meter
Meter
Single-phase
DDS607
152
Type:
Single-phase
Specification
1.5(6)A, 3(6)A
2.5(10)A, 5(20)A
5(30)A, 10(40)A
15(60)A, 20(80)A
30(100)A
Three-phase
DTS607
154
DSS607
Type:
Three-phase
Three-wire
Specification
Specification
1.5(6)A, 3(6)A
2.5(10)A, 5(20)A
5(30)A, 10(40)A
15(60)A, 20(80)A
30(100)A
1.5(6)A, 3(6)A
5(20)A, 10(40)A
15(60)A. 20(80)A
30(100)A
Management
Power Energy
Type:
Three-phase
Four-wire
157
Panel Meter
72 Series
160
96 Series
Type:
Ammeter
Voltmeter
Frequency meter
Type:
Ammeter
Voltmeter
Frequency meter
Specification
72x72mm
Specification
96x96mm
162
151
DDS607 Single-phase Electronic
Watt-hour Meter
Standard:IEC 620531-21
Function
DDS607 single-phase watt-hour meter provide:
Measuring the active energy in the single-phase AC power network with
frequency of 50Hz or 60Hz.
Measuring the active energy for enterprises, transformer substation or power substation.
And be used as the automation meter in power transmission and distribution.
Order Informationn
Power Energy
Management
Function Description
Current
specification
Reference
Type A (Import chip)
1.5(6)A
DDS607N16M4A
Type A (Import chip)
2.5(10)A
DDS607N110M4A
Type A (Import chip)
5(20)A
DDS607N120M4A
Type A (Import chip)
5(30)A
DDS607N130M6A
Type A (Import chip)
10(40)A
DDS607N140M4A
Type A (Import chip)
15(60)A
DDS607N160M4A
Type A (Import chip)
20(80)A
DDS607N180M4A
Type A (Import chip)
30(100)A
DDS607N1100M3A
Type C (Domestic chip)
1.5(6)A
DDS607N26M4C
Type C (Domestic chip)
2.5(10)A
DDS607N210M4C
Type C (Domestic chip)
5(20)A
DDS607N220M4C
Type C (Domestic chip)
5(30)A
DDS607N230M6C
Type C (Domestic chip)
10(40)A
DDS607N240M4C
Type C (Domestic chip)
15(60)A
DDS607N260M4C
Type C (Domestic chip)
20(80)A
DDS607N280M4C
Type C (Domestic chip)
30(100)A
DDS607N2100M3C
LCD without 485 communications
1.5(6)A
DDS607N16M4CD
LCD without 485 communications
2.5(10)A
DDS607N110M4CD
LCD without 485 communications
5(20)A
DDS607N120M4CD
LCD without 485 communications
5(30)A
DDS607N130M6CD
LCD without 485 communications
10(40)A
DDS607N140M4CD
LCD without 485 communications
15(60)A
DDS607N160M4CD
LCD without 485 communications
20(80)A
DDS607N180M4CD
LCD with 485 communications
1.5(6)A
DDS607N16M4CD485
LCD with 485 communications 5(20)A
DDS607N120M4CD485
LCD with 485 communications 10(40)A
DDS607N140M4CD485
LCD with 485 communications
15(60)A
DDS607N160M4CD485
LCD with 485 communications and infrared communications
1.5(6)A
DDS607N116M4CD485I
LCD with 485 communications and infrared communications 2.5(10)A
DDS607N110M4CD485I
LCD with 485 communications and infrared communications 5(20)A
DDS607N120M4CD485I
LCD with 485 communications and infrared communications 5(30)A
DDS607N130M6CD485I
LCD with 485 communications and infrared communications 10(40)A
DDS607N140M4CD485I
LCD with 485 communications and infrared communications 15(60)A
DDS607N160M4CD485I
LCD with 485 communications and infrared communications 20(80)A
DDS607N180M4CD485I
LCD with 485 communications and infrared communications
DDS607N1100M3CD485I
Note: Users need special specifications can be customized
152
30(100)A
DDS607 Single-phase Electronic
Watt-hour Meter
Standard:IEC 620531-21
Technical Data
Standard
IEC 620531-21
Certificate
KEMA
Working voltage(V)
230V
Power loss
Voltage circuit ≤2W per10VA, Current circuit ≤4VA
Optional functions
LCD display, Infrared communication, 485 communication
Normal working temp.
-10℃~+45℃
Limited working temp.
-25℃~+55℃
Normal working voltage 0.9~1.1(Ref. voltage)
Limited working voltage 0.8~1.15(Ref. voltage)
Relative humidity
<75%
Installation location
Should be installed in the height of 1.8m vertically and the angularity≤1°
Overall Dimensions
Unit: mm
Management
Power Energy
Single-phase Type A,C Meter
Single-phase LCD Meter
153
DTS607 Three-phase Four-wire
Electronic Watt-hour Meter
Standard: IEC 62053-21
Function
DTS607 Three Phase four-wire watt-hour meter provide:
Measuring the active energy in the three-phase four-wire AC power network at
frequency of 50Hz or 60Hz.
Measure the active energy of enterprises, transformer substation or power
stations, and be used as automation meters of power transmission and
distribution network.
Order Information
Voltage(V)
Grade
Current(A)
Reference
57.7/100
1
1.5(6)
DTS607WY16M4
3(6)
DTS607WY16M2
230/400
1
1.5(6)
DTS607NV16M4
3(6)
DTS607NV16M2
5(20)
DTS607NV120M4
10(40)
DTS607NV120M5
15(60)
DTS607NV120M6
20(80)
DTS607NV120M7
30(100)
DTS607NV120M8
NOTE: “M” expresses the current multiple in the standard codes.
Transformer function (H) is merely available for 1.5(6)A and 3(6)A.
Power Energy
Management
154
DTS607 Three-phase Four-wire
Electronic Watt-hour Meter
Standard: IEC 62053-21
Technical Data
Working voltage
57.7/100V, 230/400V
Power loss
Voltage circuit≤2W per10VA, Current circuit≤4VA
Optional functions
LCD display, Infrared communication, 485 communication
Normal working temp.
-10℃~+45℃
Ultimate working temp.
-25℃~+55℃
Normal working voltage
0.9~1.1(Ref. voltage)
Ultimate working voltage 0.8~1.15(Ref. voltage)
Relative humidity
<75%
Installation location
Should be installed in the height of 1.8m vertically and the
angularity≤1°.
Wiring Diagram
Wiring diagram for 3 x 57.7/100V ≤3 x 3(6)A with voltage transformer
■
Wiring diagram for 3 x 230/400V ≤3 x 3(6)A with current transformer
Management
Power Energy
■
155
DTS607 Three-phase Four-wire
Electronic Watt-hour Meter
Standard: IEC 62053-21
Wiring Diagram
■
Wiring diagram for 3 x 230/400V ≥3 x 2.5(10)A direct
pulse
■
pulse
pulse
Wiring diagram for impulse testing
Overall Dimensions
Power Energy
Management
156
pulse
Unit: mm
DSS607 Single-phase Electronic
Watt-hour Meter
Standard: IEC 62053-21
Function
DSS607 Single-phase electronic watt-hour meter provides:
Measuring the active energy in the three-phase three-wire AC power network at
frequency of 50Hz or 60Hz.
Measure the active energy of enterprises, transformer substation or power stations, and be used as automation meters of power transmission and distribution
network
Order Information
Voltage(V)
Grade
Current(A)
Reference
100
1
1.5(6)
DSS607Y16M4
3(6)
DSS607Y16M2
1.5(6)
DSS607V16M4
3(6)
DSS607V16M2
5(20)
DSS607V120M4
10(40)
DSS607V140M4
15(60)
DSS607V160M4
20(80)
DSS607V180M4
30(100)
DSS607V1100M3
1
400
NOTE: “M” expresses the current multiple in the standard codes.
Transformer function (H) is merely available for 1.5(6)A and 3(6)A.
Management
Power Energy
157
DSS607 Single-phase Electronic
Watt-hour Meter
Standard: IEC 62053-21
Technical Data
Standard
IEC 62053-21
℃~
℃
℃~
℃
~
~
<75%
Wiring Diagram
Power Energy
Management
158
■
Wiring diagram for 3 x 100V ≤3 x 3(6)A with voltage transformer
■
Wiring diagram for 3 x 400V ≤3 x 3(6)A with current transformer
DSS607 Single-phase Electronic
Watt-hour Meter
Standard: IEC 62053-21
Wiring Diagram
■
Wiring diagram for 3 x 400V ≥3 x 2.5(10)A direct
pulse
■
pulse
pulse
pulse
Wiring diagram for impulse testing
Overall Dimensions
Unit: mm
Management
Power Energy
159
72 Series Panel Meter
Standard: IEC 60051
Function
72 series panel meter provide:
72T applies to measure the current, voltage or frequency in the AC circuit.
72C applies to measure the current or voltage in the DC circuit.
Mainly be used as an indicating instrument for high or low-voltage switch cabinet, power
supply cabinet, control cabinet and other electric-control facilities in the AC transmission
circuit system
Order Information
Accuracy Specification
rating
Note
Shape(mm)
Reference
Ammeter
1.5
30/5A
AC Type
72×72×67.5
72TA30
40/5A
External connection 72×72×67.5
72TA40
50/5A
transformer
72×72×67.5
72TA50
60/5A
2 times of current
72×72×67.5
72TA60
75/5A
overload
72×72×67.5
72TA75
80/5A
72×72×67.5
72TA80
100/5A
72×72×67.5
72TA100
150/5A
72×72×67.5
72TA150
160/5A
72×72×67.5
72TA160
200/5A
72×72×67.5
72TA200
250/5A
72×72×67.5
72TA250
300/5A
72×72×67.5
72TA300
400/5A
72×72×67.5
72TA400
600/5A
72×72×67.5
72TA600
800/5A
72×72×67.5
72TA800
1000/5A
72×72×67.5
72TA1000
1600/5A
72×72×67.5
72TA1600
5000/5A
72×72×67.5
72TA5000
10000/5A
72×72×67.5
72TA10000
72×72×67.5
72TA5A
Power Energy
Management
Type
2.5
Voltmeter
5A
AC Type
Direct connection
15A
AC Type
72×72×67.5
72TA15A
20A
Direct connection
72×72×67.5
72TA20A
25A
2 times of current
72×72×67.5
72TA25A
30A
overload
72×72×67.5
72TA30A
40A
72×72×67.5
72TA40A
50A
72×72×67.5
72TA50A
60A
72×72×67.5
72TA60A
80A
72×72×67.5
72TA80A
100A
72×72×67.5
72TA100A
1.5
5A
DC Type
72×72×67.5
72CA5A
1.5
300V
AC Type
72×72×67.5
72TV300V
500V
72×72×67.5
72TV500V
600V
72×72×67.5
72TV600V
DC Type
72×72×67.5
72CV5500V
45-55HZ (200V) AC Type
72×72×67.5
72THZ01200V
500V
Frequency meter
160
1.0
72 Series Panel Meter
Standard: IEC 60051
Technical Data
Standard
IEC 60051
Dielectric strength test
Frequency 50Hz
/60Hz
Voltage 2000V, duration 1 minute
2
Impact test
Response time
Max acceleration 147m/s
Angular Deflection
90
Temp.
Humidity
-25℃~+40
(25%~80%)RH
No mildew, insects, salt mist, dew in the air,
few sands and dusts are permitted.
Shall be installed Vertically
v
Environment
:
Installation:
:
4s
。
Overall Dimensions
Management
Power Energy
161
96 Series Panel Meter
Standard: IEC 60051
Function
96 series panel meter provide:
96T applies to measure the current, voltage or frequency in the AC circuit.
96C applies to measure the current or voltage in the DC circuit.
Mainly be used as an indicating instrument for high or low-voltage switch cabinet, power
supply cabinet, control cabinet and other electric-control facilities in the AC transmission
circuit system
Order Information
Type
Ammeter
Accuracy Specification
rating
1.5
Power Energy
Management
2.5
1.5
Voltmeter
1.5
Note
Shape(mm)
Reference
30/5A
AC Type
96×96×67.5
96TA30
40/5A
External connection 96×96×67.5
96TA40
50/5A
transformer
96×96×67.5
96TA50
60/5A
96×96×67.5
96TA60
75/5A
96×96×67.5
96TA75
80/5A
96×96×67.5
96TA80
100/5A
96×96×67.5
96TA100
150/5A
96×96×67.5
96TA150
160/5A
96×96×67.5
96TA160
200/5A
96×96×67.5
96TA200
250/5A
96×96×67.5
96TA250
300/5A
96×96×67.5
96TA300
400/5A
96×96×67.5
96TA400
600/5A
96×96×67.5
96TA600
800/5A
96×96×67.5
96TA800
1000/5A
96×96×67.5
96TA1000
1600/5A
96×96×67.5
96TA1600
5000/5A
96×96×67.5
96TA5000
10000/5A
96×96×67.5
96TA10000
96×96×67.5
96TA5A
5A
AC Type
Direct connection
15A
AC Type
96×96×67.5
96TA15A
20A
Direct connection
96×96×67.5
96TA20A
25A
96×96×67.5
96TA25A
30A
96×96×67.5
96TA30A
40A
96×96×67.5
96TA40A
50A
96×96×67.5
96TA50A
60A
96×96×67.5
96TA60A
80A
96×96×67.5
96TA80A
100A
96×96×67.5
96TA100A
DC Type
96×96×67.5
96CA5A
AC Type
96×96×67.5
96TV300V
500V
96×96×67.5
96TV500V
600V
96×96×67.5
96TV600V
DC Type
96×96×67.5
96CV500
45-55HZ (200V) AC Type
96×96×67.5
96THZ01200V
5A
300V
500V
Frequency meter
1.0
162
96 Series Panel Meter
Standard: IEC 60051
Technical Data
Standard
IEC 60051
Dielectric strength test
Frequency 50Hz
/60Hz
Voltage 2000V, duration 1 minute
2
Impact test
Max acceleration 147m/s
Response time
≤ 4s
Angular Deflection
90
Temp.
Humidity:
-25℃~+40
(25%~80%)RH
No mildew, insects, salt mist, dew in the air,
few sands and dusts are permitted.
v
Shall be installed Vertically
Environment
:
Installation:
。
Overall Dimensions
Management
Power Energy
163
Time Switch Overview
KG316T
165
Max.switch times
per day:10-on-10-off,
8-on-8-off
Reset:Power-off reset
KG316TD
166
Max.switch times
per day:16-on-16-off
Reset:key-button reset
KG816A
167
Power Energy
Management
Max.switch times
per day:16-on-16-off
Reset:key-button reset
KG816B
Max.switch times
per day:8-on-8-off
Reset:key-button reset
164
167
KG316T Series Digital Time Switch
Standard: IEC 60947-5-1
KG316T Series Digital Time Switch provide:
Rated AC frequency of 50Hz, rated AC control voltage 400V or below.
Be used as time control components in automatic control circuit, according to the
scheduled time to turn-on or off the circuits.
Order Information
Output loops
Rated control voltage
Reference
10-on-10-off (Single output)
AC:230V
KG316T230
AC:400V
KG316T400
AC:230V
KG316T2230
AC:400V
KG316T2400
8-on-8-off (Double output)
Technical Data
IEC 60947-5-1
Control time
Control power
Setting Value range from 1min to168h
Operation by daily or weekly
AC-15: 240V/3A 400V/1.9A
6kW
Rated control voltage
230/400V AC
Rated thermal cur.
Accuracy
Mechanical life
10A
y
2
≥1×106 times
Electrical life
≥1×105 times
Power loss
≤3W
Temp.
Display modet
-5℃~+40℃
~
Digital LED display
Time-set Mode
Digital Keyswitch settingt
Battery
Inner alkaline battery
Install Mode
Install mounted, Din rail mounted
Using mode
Management
Power Energy
Standard
Overall Dimensions
Unit: mm
Wiring Diagram
N
OUT
PUT
LOAD
Single output
IN L1
OUT L1 OUT L2
SOURCE
INPUT
SOURCE
Function
LOAD 1
LOAD 2
Double output
165
KG316TD Series Digital Time Switch
Standard: IEC 60947-5-1
Function
KG316TD Series Digital Time Switch provide:
Rated AC frequency of 50Hz, rated control supply voltage AC 400V or below.
Any circuit equipments that need to be turned-on-or-off timely.
Order Information
Output loops
Rated control voltage
Reference
16-on-16-off
AC:230V
KG316TD230
AC:400V
KG316TD400
Technical Data
Standard
IEC 60947-5-1
Control time
Control power
Setting Value range from 1min to168h
Operation by daily or weekly
AC-15: 240V/3A 400V/1.9A
6kW
Rated control voltage
230/400V AC
Rated thermal cu r.
Accuracy
Mechanical life
10A
Electrical life
≥1×105 times
Power loss
≤3W
Temp.
Display modet
-5℃~+40℃
Digital LED display
Time-set Mode
Digital Keyswitch settingt
Battery
Inner rechangeable battery
Install Mode
Install mounted, Din rail mounted
Using mode
≥1×106 times
Power Energy
Management
Overall Dimensions
Unit: mm
Management
Power Energy
Wiring Diagram
166
KG816 Series Digital Time Switch
Standard:IEC 60947-5-1
Function
KG816 Series Digital Time Switch provide:
Rated AC frequency of 50Hz, rated AC control voltage 230V or below.
Be used as time control components in automatic control circuit, according to
the scheduled time to turn-on or off the circuits.
Order Information
KG816A
Cover
Output loops
Rated control voltage
Reference
Non-transparent cover
16-on-16-off
AC:230V
KG816A230
Transparent cover
8-on-8-off
AC:230V
KG816B230
Technical Data
Standard
IEC 60947-5-1
Control time
Setting value range from 1min to 168 hrs
Operate by daily or weekly
KG816B
Using mode
AC-15: 240V/3A; 400V/1.9A
Countrol power
≤6kW
230VAC
Rated thermal cur.
10A
Accuracy
≤2s/day
Mechanical life
≥1X106
Electrical life
≥1X105
Power loss
≤4.5W
Temp.
-5℃~+40℃
Display mode
Digital LED display
Time-set Mode
Digital Keyswitch setting
Battery
Inner rechangable battery
Install Mode
Din rail mounted
Management
Power Energy
Rated control voltage
Overall Dimensions
Unit: mm
87
36
45.5
87
66
167
Voltage Stabilizer Overview
Single-phase
TND
169
Type: Single-phase
Specification: 0.5kVA, 1kVA
1.5kVA, 2kVA, 3kVA, 5kVA,
7kVA, 10kVA, 15kVA, 20kVA, 30kVA
Three-phase
SJW
171
Type: Three-phase
Specification: 1.5kVA, 3kVA
4.5kVA, 6kVA, 9kVA, 15kVA,
20kVA, 30kVA, 45kVA, 60kVA
Power Energy
Management
SBW
173
Type: Three-phase Compensation
Specification: 10kVA, 15kVA
30kVA, 50kVA, 100kVA, 150kVA,
200kVA, 250kVA, 300kVA, 400kVA,
500kVA, 600kVA, 800kVA
168
TND Single-phase Full Automatic
AC Voltage Stabilizer
Standard: EN 61000-6-2 EN 61000-6-4 EN 61558-1
Function
TND single-phase AC voltage stabilizer provide:
This product is constructed by connecting three stabilizers with Y-connection
Wide input voltage range, high efficiency, over-load protection, short adjusting time,
high regulation accuracy, same input and output voltage waveform, small volume,
less weight.
It's available in the electric equipments and facilities in housing, school, shop, office
and precision instrument for scientific experiment.
Order Information
Shape
Desktop
Cabinet
Desktop
Power
rating
Europe plug
British plug
Terminal connect
220V
0.5K
TNDP5HE220
TNDP5HB220
-
1K
TND1HE220
TND1HB220
-
1.5K
TND1P5HE220
TND1P5HB220
-
2K
-
-
TND2H220
3K
-
-
TND3H220
5K
-
-
TND5H220
7K
-
-
TND7H220
10K
10K
-
-
TND10H220
TND10GH220
15K
-
-
TND15GH220
20K
-
-
TND20GH220
30K
-
-
TND30GH220
0.5K
TNDP5HE230
TNDP5HB230
-
1K
TND1HE230
TND1HB230
-
1.5K
TND1P5HE230
TND1P5HB230
-
2K
-
-
TND2H230
3K
-
-
TND3H230
5K
-
-
TND5H230
7K
-
-
TND7H230
10K
-
-
TND10H230
10K
-
-
TND10GH230
15K
-
-
TND15GH230
20K
-
-
TND20GH230
30K
-
-
TND30GH230
220V
230V
230V
Reference
Management
Power Energy
Cabinet
Output
voltage
169
TND Single-phase Full Automatic
AC Voltage Stabilizer
Standard: EN 61000-6-2 EN 61000-6-4 EN 61558-1
Technical Data
Type
TND0.5kVA~5kVA
Voltage regulation accuracy 220±4%,110±4%
Output voltage Undervoltage protection
Overvoltage protection
TND7kVA~30kVA
220±4%
184V±4V(set up according to the customers request)
246V±4V
Phase
single-phase
Input voltage range
160V~240V
Efficiency
>90%
Voltage regulation speed
<1s(when input voltage change 10%)
Frequency
50/60Hz
Enviroment
-50℃~40℃ below 90%
temperature,relative temperature
2(500VA), 4(1000VA), 6(1500VA), 8(2000VA)
12(3000VA), 20(5000VA), 25(7000VA), 40(10KVA)
85(15KVA), 73(20KVA), 109(30KVA)
1500V/1min
Rated maximum output current(A)
Withstand voltage
Standard: EN 61000-6-2 EN 61000-6-4 EN 61558-1
Certification: CE
Overall Dimensions
Unit: mm
Power Energy
Management
Product shape
Model
Wide×Length×Hight
Desktop
TND-0.5 W
190
L
160
H
135
TND-1 205
190
155
TND-1.5 205
190
155
TND-2 240
270
200
TND-3 225
305
235
TND-5 225
310
290
TND-7 240
387
360
TND-10 240
387
360
TND-10 310
340
535
TND-15 340
360
640
TND-20 340
380
780
TND30
425
390
845
Cabinet type
170
SJW Three-phase Full Automatic
AC Voltage Stabilizer
Function
SJW three-phase AC voltage stabilizer provide:
This product is constructed by connecting three stabilizers with Y-connection
Wide input voltage range, high efficiency, over-load protection, short adjusting
time, high regulation accuracy, same input and output voltage waveform, small
volume, less weight.
It's available in the electric equipments and facilities in housing, factory, shool,
shop, office and precision instrument for scientific experiment.
Order Information
Shape
Desktop
Cabinet
Power rating
Reference
1.5 kVA
SJW1P5
3 kVA
SJW3
4.5 kVA
SJW4P5
6 kVA
SJW6G
9 kVA
SJW9G
15 kVA
SJW15G
20 kVA
SJW20G
30 kVA
SJW30G
45 kVA
SJW45G
Technical Data
Type
Output voltage
SJW 1.5KVA~60KVA
Voltage regulation accuracy
380V ±4%
Low-voltage protection
340V±7V(adjustable)
Over-voltage protection
420V ±7V
280~415V
Efficiency
90%
Voltage regulation speed
<1s(voltage fluctuation≥10%)
Frequency
50/60Hz
Waveform distortion:
No additional distortion
Withstand voltage
1500V/1min
Temperature rise
<+60℃
Environment temp.
-5℃~+40℃
Management
Power Energy
Input voltage range
Overall Dimensions
171
SJW Three-phase Full Automatic
AC Voltage Stabilizer
Overall Dimensions
■
Cabinet
ELECTRIC
WORKING
PHASE A
WORKING
PHASE B
WORKING
PHASE C
PROTECT
OUTPUT VOLTAGE
VOLTAGE TEST
SJW9 HIGH ACCURACY FULL-AUTOMATIC
AC VOLTAGE STABILIZER
Shape
Desktop
Power Energy
Management
Cabinet
172
Model
Wide x Length x Hight
W
L
H
SJW-1P5
485
315
165
SJW-3
485
315
165
SJW-4.5
485
315
165
SJW-6
278
322
665
SJW-9
320
325
750
SJW-15
350
350
855
SJW-20
425
390
845
SJW-30
440
415
875
SJW-45
550
450
1170
SJW-60
600
495
1300
SBW Three-phase Compensation
AC Voltage Stabilizer
Function
SBW three-phase compensation AC voltage stabilizer provide:
This product is designed and developed with the international advanced
compensation technology. It can keep the output voltage in steady state
automatically when the network voltage fluctuated or the load current varied.
It's provided with over-voltage, over-current, phase sequence protection function.
Order Information
Power rating
Reference
10kVA
SBW10
15kVA
SBW15
30kVA
SBW30
50kVA
SBW50
100kVA
SBW100
150kVA
SBW150
200kVA
SBW200
250kVA
SBW250
300kVA
SBW300
400kVA
SBW400
500kVA
SBW500
600kVA
SBW600
800kVA
SBW800
Technical Data
Output voltage
SBW 10KVA~1600KVA
Voltage regulation accuracy
380V ±3%
Low-voltage protection
340V ±7V
Over-voltage protection
425V ±7V
Input voltage range
304~456 V
Efficiency
≥98%
Voltage regulation speed
<1s(voltage fluctuation≥10%)
Frequency
50/60Hz
Waveform distortion
≤1%
Insulation resistance
≥2MΩ
Withstand voltage
Temperature rise
2000V/1min
<+60℃
Environment temp.
-5℃~+40℃
Management
Power Energy
Type
173
SBW Three-phase Compensation
AC Voltage Stabilizer
Overall Dimensions
Unit: mm
Model
Power Energy
Management
174
Wide x Length x Hight
W
L
H
SBW-10
750
580
1170
SBW-20
750
580
1170
SBW-50
800
570
1300
SBW-100
850
645
1460
SBW-200
1050
750
1850
SBW-500
1400
1100
2100
SBW-800
1350
1100
2200
SBW-1000
1050
750
2200
SBW-1600
1300
1100
2200
Contents
Industrial Control Components
Control Signal
175-202
LD11
Indicator Light
177
LAY5
Pushbutton Switches
181
LAY7
Pushbutton Switches
191
LAY8
Pushbutton Switches
197
Accessories
203-221
RT16
Fuse
203
RT18
Fuse
206
CCF
Series Cable Connector
209
CDPM
Moving Industrial Plugs
211
CDP
Fixed Industrial Plugs
212
CDSM
Moving Industrial Sockets
213
CDSF
Fixed Industrial Sockets
214
CDPS
Multi-function Plugs and Sockets
215
TB
Series Copper Terminal Blocks
217
DINR
Din-rail
221
Industrial Control
Components
175
Control Signal Overview
Indicator Light
LD11
177
IP degree:IP65
Specification
AC/DC: 6V 12V 24V 36V 48V 110V 230V
AC: 230V 400V
Pushbutton Switches
LAY5
181
LAY7
IP degree:IP55
IP degree:IP55
Specification
Specification
AC-15: 380V/2A 230V/3.3A
AC-15: 660V/1.1A
DC-13: 230V/0.5A 110V/1.1A
400V/2.0A 230V/3.3A
DC-13: 440V/0.25A
230V/0.5A 110V/1A
LAY8
IP degree:IP55
Industrial Control
Components
Specification
AC-15: 660V/1.5A
400V/2.5A 230V/4.5A
DC-13: 440V/0.2A
230V/0.4A 110V/0.8A
176
197
191
LD11 Indicator Light
Standard: IEC 60947-5
Function
LD11 Series of indicator light provide:
Pilot signal, anticipating signals
Emergency signals and other instructions incidents signal use
Technical Data
Rated voltage(V)
AC/DC
6 12 24 36 48 110 230
AC
230 400
Rated current(mA)
Working life(H)
Brightness of light(cd/m2)
Power frequency withstand voltage
Degree of protection
≤50
30000
≤20
≥40
2500V AC 1min
IP65
Order Information
Installation
dimension
22:¢22
Type
Step-down
Type
A: Full cover 2: Resistance
head & long type
4: Capacitance
terminal
type
Button colour
Reference
AC.DC 6V
LD1122A21T7
LD1122A21T3
LD1122A21T4
LD1122A21T5
LD1122A21T8
LD1122A21J7
LD1122A21J3
LD1122A21J4
LD1122A21J5
LD1122A21J8
LD1122A21B7
LD1122A21B3
LD1122A21B4
LD1122A21B5
LD1122A21B8
LD1122A21F7
LD1122A21F3
LD1122A21F4
LD1122A21F5
LD1122A21F8
LD1122A21M7
LD1122A21M3
LD1122A21M4
LD1122A21M5
LD1122A21M8
LD1122A41M7
LD1122A41M3
LD1122A41M4
LD1122A41M5
LD1122A41M8
AC.DC 12V
AC.DC 24V
AC.DC 110V
AC.DC 230V
AC 230V
Overall Dimensions
Unit:mm
Industrial Control
Components
Rated voltage
177
LD11 Indicator Light
Standard: IEC 60947-5
Order Information
Installation
dimension
Type
Step-down
Type
Button colour
Rated voltage
Reference
AC 400V
LD1122A41Q7
LD1122A41Q3
LD1122A41Q4
LD1122A41Q5
LD1122A41Q8
22:¢22
B: Half cover 2: Resistance
head&long
type
terminal
4: Capacitance
type
AC.DC 6V
LD1122B21T7
LD1122B21T3
LD1122B21T4
LD1122B21T5
LD1122B21T8
AC.DC 12V
LD1122B21J7
LD1122B21J3
LD1122B21J4
LD1122B21J5
LD1122B21J8
AC.DC 24V
LD1122B21B7
LD1122B21B3
LD1122B21B4
LD1122B21B5
LD1122B21B8
AC.DC 110V
LD1122B21F7
LD1122B21F3
LD1122B21F4
LD1122B21F5
LD1122B21F8
AC.DC 230V
LD1122B21M7
LD1122B21M3
LD1122B21M4
LD1122B21M5
Industrial Control
Components
LD1122B21M8
AC 230V
LD1122B41M7
LD1122B41M3
LD1122B41M4
LD1122B41M5
LD1122B41M8
AC 400V
LD1122B41Q7
LD1122B41Q3
LD1122B41Q4
LD1122B41Q5
LD1122B41Q8
178
Overall Dimensions
Unit:mm
LD11 Indicator Light
Standard: IEC 60947-5
Order Information
Installation
dimension
22:¢22
Type
Step-down
Type
C: Full cover 2: Resistance
head & short type
terminal
4: Capacitance
type
Button colour
Rated voltage
Reference
AC.DC 6V
LD1122C21T7
Overall Dimensions
Unit:mm
LD1122C21T3
LD1122C21T4
LD1122C21T5
LD1122C21T8
AC.DC 12V
LD1122C21J7
LD1122C21J3
LD1122C21J4
LD1122C21J5
LD1122C21J8
AC.DC 24V
LD1122C21B7
LD1122C21B3
LD1122C21B4
LD1122C21B5
LD1122C21B8
AC 230V
LD1122C41M7
LD1122C41M3
LD1122C41M4
LD1122C41M5
LD1122C41M8
AC 400V
LD1122C41Q7
LD1122C41Q3
LD1122C41Q4
LD1122C41Q5
LD1122C41Q8
Industrial Control
Components
179
LD11 Indicator Light
Standard: IEC 60947-5
Order Information
Installation
dimension
22:¢22
Type
Step-down
Type
D: Half cover 2: Resistance
head&short type
terminal
4: Capacitance
type
Button colour
Rated voltage
Reference
AC.DC 6V
LD1122D21T7
LD1122D21T3
LD1122D21T4
LD1122D21T5
LD1122D21T8
AC.DC 12V
LD1122D21J7
LD1122D21J3
LD1122D21J4
LD1122D21J5
LD1122D21J8
AC.DC 24V
LD1122D21B7
LD1122D21B3
LD1122D21B4
LD1122D21B5
LD1122D21B8
AC 230V
LD1122D41M7
LD1122D41M3
LD1122D41M4
LD1122D41M5
LD1122D41M8
AC 400V
LD1122D41Q7
LD1122D41Q3
LD1122D41Q4
LD1122D41Q5
LD1122D41Q8
Industrial Control
Components
180
Overall Dimensions
Unit:mm
LAY5 Pushbutton Switches
Standard: IEC 60947-5
Function
LAY5 series of pushbutton switches provide:
Control and indicate the status of the circuit
Technical Data
Usage mode
Rated valve
Rated voltage (Ue) V
AC-15
Rated current (Ie) A
380
2
230
3.3
Rated voltage (Ue) V
Rated current (Ie) A
230
110
0.5
1.1
DC-13
Mechanical endurance
105
Electric endurance
105
3 0 Flush type , 1 0 Illuminated
1 Emergency stop, Selective-type, Key-tpye
AC6( Flush type ) DC3( Illuminated )
1 Emergency stop, Selective-type, Key-tpye
Rated thermal current (Ith) A
6
IP55
Protect degree
Illuminated pushbutton
Power supplier voltage
6
12
24
≤ 50%(40 )
90%(20
V
110
230
380
LED
Neon lamp
Filament lamp
Working Condition
Temperature
Ralative humidity
-5
~+40
≤ 2000m
Pollution grade
3
)
Industrial Control
Components
Above sea level
181
LAY5 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Flush Button
Name
Unit: MM
Material
Type
Color
NO + NC
1 White
1: 1NO
LAY5BA15
2 Black
2: 1NC
LAY5BA25
3 Green
3: 2NO
LAY5BA31
4 Red
4: 2NC
LAY5BA42
5 Yellow
5: 1NO+1NC
LAY5BA55
LAY5
B Metal
A Momentary
6 Blue
E Plastic
A Momentary
1 White
1: 1NO
LAY5EA15
2: 1NC
LAY5EA25
3 Green
3: 2NO
LAY5EA31
4 Red
4: 2NC
LAY5EA42
5 Yellow
5: 1NO+1NC
LAY5EA55
LAY5EA65
Unit: MM
Material
Type
B Metal
D Selective
button with
short handle
Operation
NO + NC
LAY5
Industrial Control
Components
182
Dimension
LAY5BA65
2 Black
6 Blue
Selective Button Switch
Name
Reference
2:2p
C R
3:3p
L C R
4:2 p
C R
5:3p
L C R
Reference
1: 1NO
LAY5BD21
2: 1NC
LAY5BD25
3: 2NO
LAY5BD33
4: 2NC
LAY5BD45
5: 1NO+1NC
LAY5BD53
Dimension
LAY5 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Selective Switches
Name
Material
Unit: MM
Operation
Type
NO + NC
LAY5
E Plastic
B Metal
E Plastic
D Selective
switch with
short handle
2:2 p
3:3 p
C R
L C R
4:2p
C R
5:3 p
L C R
J Selective 2:2 p
switch with
short handle 3:3 p
C R
J Selective
switch with
short handle
L C R
4:2p
C R
5:3 p
L C R
2:2 p
C R
3:3 p
L C R
4:2p
C R
5:3 p
L C R
Reference
1: 1NO
LAY5ED21
2: 1NC
LAY5ED25
3: 2NO
LAY5ED33
4: 2NC
LAY5ED45
5: 1NO+1NC
LAY5ED55
1: 1NO
LAY5BJ21
2: 1NC
LAY5BJ25
3: 2NO
LAY5BJ33
4: 2NC
LAY5BJ45
5: 1NO+1NC
LAY5BJ55
1: 1NO
LAY5EJ21
2: 1NC
3: 2NO
LAY5EJ25
LAY5EJ33
4: 2NC
LAY5EJ45
5: 1NO+1NC
LAY5EJ55
Dimension
Industrial Control
Components
183
LAY5 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Key-operated Selective Switches
Name
Material
Unit: MM
Operation
Type
NO + NC
LAY5
B Metal
E Plastic
G Key-operated 2:2 p
selective
switches
3:3 p
C R
L C R
4:2p reset
C R
5:3 p reset
L C R
C R
G Key-operated 2:2p
selective
switches
3:3 p
L C R
4:2p reset
C R
5:3 p reset
L C R
Reference
1: 1NO
LAY5BG21
2: 1NC
LAY5BG25
3: 2NO
LAY5BG33
4: 2NC
LAY5BG45
5: 1NO+1NC
LAY5BG55
1: 1NO
LAY5EG21
2: 1NC
LAY5EG25
3: 2NO
LAY5EG33
4: 2NC
LAY5EG45
5: 1NO+1NC
LAY5EG55
Mushroom Button
Name
Unit: MM
Material
Type
Color
40 Mushroom
3 Green
4 Red
NO + NC
LAY5
Industrial Control
Components
B Metal
C:
Reference
1: 1NO
LAY5BC31
2: 1NC
LAY5BC42
3: 2NO
LAY5BC35
4: 2NC
LAY5BC45
5: 1NO+1NC
184
Dimension
Dimension
LAY5 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Mushroom Button
Name
Unit: MM
Material
Type
Color
60 Mushroom
3 Green
4 Red
NO + NC
LAY5
B Metal
R:
Reference
1: 1NO
LAY5BR31
2: 1NC
LAY5BR42
3: 2NO
LAY5BR35
4: 2NC
LAY5BR45
Dimension
5: 1NO+1NC
E Plastic
C:
40 Mushroom
3 Green
4 Red
1: 1NO
LAY5EC31
2: 1NC
LAY5EC42
3: 2NO
LAY5EC35
4: 2NC
LAY5EC45
5: 1NO+1NC
E Plastic
R:
60 Mushroom
3 Green
4 Red
1: 1NO
LAY5ER31
2: 1NC
LAY5ER42
3: 2NO
LAY5ER35
4: 2NC
LAY5ER45
5: 1NO+1NC
Industrial Control
Components
185
LAY5 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Emergency Stop Button
Name
Material
Unit: MM
Type
Head
Color
NO + NC
3 Green
1: 1NO
LAY5BS431
LAY5
B Metal
S: Emergency
4:
30
4 Red
Reference
2: 1NC
LAY5BS442
3: 2NO
LAY5BS435
4: 2NC
LAY5BS445
5: 1NO+1NC
B Metal
S: Emergency
5:
40
3 Green
1: 1NO
LAY5BS531
4 Red
2: 1NC
LAY5BS542
3: 2NO
LAY5BS535
4: 2NC
LAY5BS545
5: 1NO+1NC
B Metal
S: Emergency
6:
60
3 Green
4 Red
1: 1NO
LAY5BS631
2: 1NC
LAY5BS642
3: 2NO
LAY5BS635
4: 2NC
LAY5BS645
5: 1NO+1NC
Industrial Control
Components
186
Dimension
LAY5 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Emergency Stop Button
Name
Unit: MM
Material
Type
E Plastic
S: Emergency
Head
Color
NO + NC
LAY5
4:
30
Reference
3 Green
1: 1NO
LAY5ES431
4 Red
2: 1NC
LAY5ES442
3: 2NO
LAY5ES435
4: 2NC
LAY5ES445
Dimension
5: 1NO+1NC
E Plastic
S: Emergency
5:
40
3 Green
4 Red
1: 1NO
LAY5ES531
2: 1NC
LAY5ES542
3: 2NO
LAY5ES535
4: 2NC
LAY5ES545
5: 1NO+1NC
E Plastic
S: Emergency
6:
60
3 Green
1: 1NO
LAY5ES631
4 Red
2: 1NC
LAY5ES642
3: 2NO
LAY5ES635
4: 2NC
LAY5ES645
5: 1NO+1NC
Industrial Control
Components
187
LAY5 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Unit: MM
Two-head Button
Name
Material
Type
Head
No.of head
NO + NC
LAY5
Industrial Control
Components
188
Reference
B Metal
L8: Two-head 3: Flush button
2: 2
5: 1NO+1NC
LAY5BL8325
B Metal
L8 : Two-head 4: One high,
one low
2: 2
5: 1NO+1NC
LAY5BL8425
Dimension
LAY5 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Illuminated Pushbutton Switches
Name
Material
Type
Color
Voltage
LAY5
NO + NC
*
B Metal
W3 Flush
Light
*
1 White
T:6V
1: 1NO
N Neon
LAY5BW31*5
3 Green
B:24V
2: 1NC
L LED
LAY5BW33*1
4 Red
F:110V
3: 2NO
5 Yellow
Blank:
N:230V
4: 2NC
6 Blue
Q:380V
5: 1NO+1NC
Filament
*
*
LAY5BW34*2
*
LAY5BW35*5
*
LAY5BW36*5
*
LAY5BW37*5
*
LAY5BW38*5
*
T:6V
5: 1NO+1NC N Neon
LAY5BW84*5*
7 Pure white
8 Pure blue
B Metal
W8:Two
head
4 One high
one low
B:24V
L LED
F:110V
Blank:
N:230V
Filament
Q:380V
E Plastic
W3 Flush
T:6V
1: 1NO
N Neon
LAY5EW31*5
3 Green
B:24V
2: 1NC
L LED
LAY5EW33*1
4 Red
F:110V
3: 2NO
N:230V
Blank:
5 Yellow
4: 2NC
Q:380V
Filament
6 Blue
5: 1NO+1NC
*
*
LAY5EW34*2
*
LAY5EW35*5
*
LAY5EW36*5
*
LAY5EW37*5
*
LAY5EW38*5
*
T:6V
5: 1NO+1NC N Neon
LAY5EW84*5*
8 Pure blue
W8:Two
head
4 One high
one low
B:24V
L LED
F:110V
Blank:
Filament
N:230V
Industrial Control
Components
1 White
7 Pure white
E Plastic
Reference
Q:380V
Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V
The pure white and pure blue are only available for LED lamp.
189
LAY5 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Indication Lamp
Name
Unit: MM
Material
Type
LAY5
Voltage
Color
*
*
B Metal
V: Indication
Light
T:6V
1 White
N Neon
B:24V
3 Green
L LED
F:110V
4 Red
N:230V
5 Yellow
Blank:
Q:380V
6 Blue
7 Pure white
8 Pure blue
Filament
Reference
Dimension
LAY5BV*1*
LAY5BV*3*
LAY5BV*4*
LAY5BV*5*
LAY5BV*6*
LAY5BV*7*
LAY5BV*8*
Base
Name
Type
Contact
LAY5
BE Auxiliary contact
101: 1NO
LAY5BE101
102: 1NC
LAY5BE102
103: 2NO
LAY5BE103
104: 2NC
LAY5BE104
105: 1N0+1NC
LAY5BE105
Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V
The pure white and pure blue are only available for LED lamp.
Industrial Control
Components
190
Reference
Dimension
LAY7 Pushbutton Switches
Standard: IEC 60947-5
Function
LAY7 series of pushbutton switches provide:
Control and indicate the status of the circuit
Technical Data
Usage mode
Rated valve
Rated voltage (Ue) V
AC-15 Rated current (Ie) A
660
380
230
1.1
2
3.3
Rated voltage (Ue) V
DC-13
Rated current (Ie) A
440
230
110
0.25
0.5
1
Mechanical endurance 105
3 0 Flush type , 1 0 Illuminated
0 . 5 Emergency stop, Selective-type,,Key-tpye
Electric endurance
6 Flush type , 1 Illuminated
0 . 5 Emergency stop,,Selective-type,,Key-tpye
105
Rated thermal current l
th
Operation frequency
Contact resistance
A
T /h
m
10
1200
≤ 50
Protect degree
IP55
Illuminated pushbutton
Power supplier voltage
Working voltage
Lifetime
(Ue)V
h
Filament lamp
Neon lamp
LED
6, 12, 24
110, 220, 380
6, 12, 24
≥ 1000
≥ 2000
≥ 3000
Working Condition
Temperature
-5
Ralative humidity
≤ 50%(40 )
Above sea level
≤ 2000m
Pollution grade
3
~+40
90%(20
)
Industrial Control
Components
191
LAY7 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Flush Button
Name
Unit: MM
Type
NO + NC
Color
Installation
LAY7
BN Momentary
Reference
1 White
2 Black
2
22
LAY711BN12
01: 1NC
3
25
LAY711BN22
20: 2NO
3 Green
4
30
LAY711BN32
02: 2NC
4 Red
5 Yellow
LAY711BN42
6 Blue
LAY711BN62
10: 1NO
11: 1NO+1NC
10: 1NO
BNZS Maintained
01: 1NC
LAY711BN52
3 Green
2
22
LAY711BNZS32
4 Red
3
25
LAY711BNZS42
4
30
3 Green
2
22
LAY711GN32
4 Red
3
25
LAY711GN42
4
30
3 Green
2
22
LAY711GNZS32
4 Red
3
25
LAY711GNZS42
4
30
20: 2NO
02: 2NC
11: 1NO+1NC
10: 1NO
GN Momentary
01: 1NC
20: 2NO
02: 2NC
11: 1NO+1NC
Industrial Control
Components
10: 1NO
GNZS Maintained
01: 1NC
20: 2NO
02: 2NC
11: 1NO+1NC
192
Dimension
LAY7 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Unit: MM
Flush Button
Name
LAY7
NO + NC
Type
10: 1NO
JN Full protection
Installation
Color
01: 1NC
Reference
3 Green
2
22
LAY711JN32
4 Red
3
25
LAY711JN42
4
30
20: 2NO
Dimension
02: 2NC
11: 1NO+1NC
Unit: MM
Selective Switches
Name
Operation
NO + NC
Type
10: 1NO
X Selective
button with
20:2p
01: 1NC
20: 2NO
short handle
21:2p
Color
Installation
LAY7
C R
C R
2 Black
2
22
LAY711X2022
3 Green 3
25
LAY711X2132
4
30
LAY711X3042
4 Red
01: 1NC
20: 2NO
30:3p
L C R
31:3p
L C R
33:3p
L C R
XB Selective 20:2
button with
long handle 21:2
C R
C R
02: 2NC
11: 1NO+1NC
LAY720X3022
2 Black
2
22
LAY711XB2022
3 Green 3
25
LAY711XB2132
4
30
LAY711XB3042
Red
4
Industrial Control
Components
10: 1NO
Dimension
LAY711X3122
02: 2NC
11: 1NO+1NC
Reference
LAY720XB3022
30:3
L C R
31:3
L C R
33:3
L C R
LAY720XB3322
193
LAY7 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Key-operated Selective Switches
Name
NO + NC
Unit: MM
Type
Installation
Operation
LAY7
10: 1NO
Y Key-operated
20:2p
C R
21:2p
C R
30:3p
L C R
31:3p
L C R
33:3p
L C R
01: 1NC
20: 2NO
Reference
2
22
LAY711Y202
3
25
LAY711Y212
4
30
LAY711Y302
LAY711Y312
02: 2NC
11: 1NO+1NC
LAY720Y332
Unit: MM
Mushroom Button
Name
NO + NC
Type
Color
Installation
LAY7
10: 1NO
M Momentary
01: 1NC
Reference
3 Green
2
22
LAY711M32
4 Red
3
25
LAY711M42
4
30
3 Green
2
22
LAY711MZS32
4 Red
3
25
LAY711MZS42
4
30
20: 2NO
02: 2NC
11: 1NO+1NC
10: 1NO
Industrial Control
Components
01: 1NC
20: 2NO
02: 2NC
11: 1NO+1NC
194
Dimension
MZS Maintained
Dimension
LAY7 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Unit: MM
Emergency Stop Button
Name
NO + NC
Type
Installation
Color
LAY7
10: 1NO
01: NC
20: 2NC
02: 2NC
11: 1NO+1NC
ZS:Emergency
3: Green
4: Red
2: Φ22
3: Φ25
4: Φ30
Reference
Dimension
LAY710ZS32
LAY701ZS42
LAY711ZS32
LAY711ZS42
Unit: MM
Illuminated Pushbutton Switches
Name
NO + NC
Type
Color
LAY7
Voltage
Installation
*
10: 1NO
D: Momentary
01: NC
(Illuminated)
20: 2NC
02: 2NC
11: 1NO+1NC
3: Green
4: Red
5: Yellow
6:Blue
7:Pure white
8:Pure blue
2: Φ22
T: 6V
B: 24V 3: Φ25
F: 110V 4: Φ30
N: 230V
Q: 380V
DZS: Maintained
10: 1NO
(Illuminated)
01: NC
20: 2NC
02: 2NC
11: 1NO+1NC
3: Green
4: Red
5: Yellow
6:Blue
7:Pure white
8:Pure blue
T: 6V
2: Φ22
B: 24V 3: Φ25
F: 110V 4: Φ30
N: 230V
Q: 380V
Light
*
N Neon
L LED
Blank:
Filament
N Neon
L LED
Blank:
Filament
Reference
Dimension
LAY711D3*2 *
LAY711D4*2 *
LAY711D5*2
*
*
LAY711D7*2
*
LAY711D8*2
*
LAY711D6*2
LAY711DZS2*2 *
LAY711DZS4*2*
LAY711DZS5*2*
LAY711DZS6*2*
LAY711DZS7*2 *
LAY711DZS8*2*
3: Green
4: Red
DMZS: Maintained 3: Green
10: 1NO
4: Red
(Illuminated)
01: NC
20: 2NC
02: 2NC
11: 1NO+1NC
T: 6V
2: Φ22
B: 24V 3: Φ25
F: 110V 4: Φ30
N: 230V
Q: 380V
T: 6V
2: Φ22
B: 24V 3: Φ25
F: 110V 4: Φ30
N: 230V
Q: 380V
N Neon
L LED
Blank:
Filament
LAY711DM3*2 *
LAY711DM4*2
*
N Neon
LAY711DMZS3*2
L LED
LAY711DMZS4*2
Blank:
Filament
Industrial Control
Components
DM: Momentary
10: 1NO
(Illuminated)
01: NC
20: 2NC
02: 2NC
11: 1NO+1NC
*
*
Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V
The pure white and pure blue are only available for LED lamp.
195
LAY7 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Illuminated Selective Switches
Name
NO + NC
Unit: MM
Operation
Type
Light
Color Voltage Install
LAY7
*
XD: Selective 20:2p
(Illuminated)
10: 1NO
01: 1NC
C R
Reference
3 Green
T: 6V
2
22
N Neon
LAY711XD203*2
4 Red
B: 24V
3
25
L LED
LAY711XD204*2
F: 110V
4
30
Blank:
Filament
20: 2NO
02: 2NC
*
N: 230V
30:3p L C R
Q: 380V
11: 1NO+1NC
*
*
LAY711XD303*2
*
LAY711XD304*2
*
Indication Lamp
Name
Unit: MM
Type
Color
Voltage
Install
*
LAY7
Reference
XD1 Filament
1 White
T: 6V
XD2 Neon
3 Green
B: 24V
LAY7XD23*2
XD3 LED
4 Red
F: 110V
LAY7XD34*2
5 Yellow
N: 230V
LAY7XD15*2
6 Blue
Q: 380V
LAY7XD26*2
2
22
Dimension
LAY7XD11*2
7 Pure white
LAY7XD37*2
8 Pure blue
LAY7XD38*2
Base
Unit: MM
Name
Type
Contact
Industrial Control
Components
LAY7
BE Auxiliary contact
101: 1NO
Reference
LAY7BE101
102: 1NC
LAY7BE102
103: 2NO
LAY7BE103
104: 2NC
LAY7BE104
105: 1N0+1NC
LAY7BE105
Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V
The pure white and pure blue are only available for LED lamp.
196
Dimension
Dimension
LAY8 Pushbutton Switches
Standard: IEC 60947-5
Function
LAY8 series of pushbutton switches provide:
Control and indicate the status of the circuit
Technical Data
Usage mode
AC-15
DC-13
Rated valve
Rated voltage (Ue) V
Rated current (Ie) A
660
380
230
1.5
2.5
4.5
Rated voltage (Ue) V
Rated current (Ie) A
440
230
0.2
0.4
110
0.8
Mechanical endurance 105
3 0 Flush type , 3 Selective
0 . 5 Emergency stop, Key-tpye
Electric endurance
6( Flush type ) , 1( Illuminated )
105
0 . 5 Emergency stop, Key-tpye
10
Rated thermal current(Ith)A
Contact resistance
≤50
m
IP55
Protect degree
Illuminated pushbutton
Rated working voltage (Ue)V 6
12
24
36
48
110
220
Power supply
AC, DC
AC
Rated working current (Ie)mA
≤ 50
≤ 20
230
380
Working Condition
-5
~+40
Ralative humidity
≤ 50%(40 )
Above sea level
≤ 2000m
Pollution grade
3
90%(20
)
Industrial Control
Components
Temperature
197
LAY8 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Unit: MM
Flush Button
Name
LAY8
NO + NC
Type
10: 1NO
BN Momentary
01: 1NC
20: 2NO
02: 2NC
11: 1NO+1NC
10: 1NO
BNZS Maintained
01: 1NC
20: 2NO
Color
1 White
2 Black
Reference
LAY811BN1
LAY811BN2
3 Green
LAY811BN3
4 Red
5 Yellow
LAY811BN4
6 Blue
LAY811BN6
LAY811BN5
3 Green
LAY811BNZS3
4 Red
5 Yellow
LAY811BNZS4
3 Green
LAY811S3
4 Red
5 Yellow
LAY811S4
LAY811BNZS5
02: 2NC
11: 1NO+1NC
10: 1NO
01: 1NC
20: 2NO
02: 2NC
11: 1NO+1NC
Industrial Control
Components
198
S Waterproof
LAY811S5
Dimension
LAY8 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Unit: MM
Selective Switches
Name
NO + NC
Type
10: 1NO
X Selective
button with
short handle
Operation
Color
LAY8
01: 1NC
20: 2NO
20:2p
21:2p
C R
C R
2 Black
LAY811X202
3 Green
LAY811X213
4 Red
LAY811X304
02: 2NC
Dimension
LAY811X312
11: 1NO+1NC
10: 1NO
XB Selective
01: 1NC
button with
20: 2NO
long handle
30:3p
L C R
31:3p
L C R
33:3p
L C R
20:2p
C R
21:2p
C R
02: 2NC
11: 1NO+1NC
Reference
LAY820X332
2 Black
LAY811XB202
3 Green
LAY811XB213
4 Red
LAY811XB304
LAY811XB312
30:3p
L C R
31:3p
L C R
33:3p
L C R
LAY820XB332
Industrial Control
Components
199
LAY8 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Key-operated Selective Switch
Name
NO + NC
Unit: MM
Type
Operation
LAY8
10: 1NO
Y Key-operated
20:2p
C R
21:2p
C R
30:3p
L C R
31:3p
L C R
33:3p
L C R
01: 1NC
Reference
LAY811Y20
LAY811Y21
20: 2NO
02: 2NC
LAY820Y30
LAY811Y31
11: 1NO+1NC
LAY811Y33
Mushroom Button
Name
Unit: MM
NO + NC
Type
10: 1NO
M Momentary
Color
LAY8
01: 1NC
Reference
3 Green
LAY811M3
4 Red
LAY811M4
20: 2NO
02: 2NC
11: 1NO+1NC
Industrial Control
Components
10: 1NO
01: 1NC
20: 2NO
02: 2NC
11: 1NO+1NC
200
Dimension
MZS Maintained
3 Green
4 Red
LAY811MZS3
LAY811MZS4
Dimension
LAY8 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Unit: MM
Emergency Stop Button
Name
Type
NO + NC
Color
Reference
LAY8
ZS Emergency
10: 1NO
01: 1NC
3 Green
LAY811ZS3
4 Red
LAY811ZS4
Dimension
20: 2NO
02: 2NC
11: 1NO+1NC
Unit: MM
Illuminated Pushbutton Switches
Name
LAY8
NO + NC
Type
Color
Voltage
Power
*
10: 1NO
01: 1NC
D: Momentary
(Illuminated)
20: 2NO
02: 2NC
11: 1NO+1NC
3: Green
4: Red
5: Yellow
6:Blue
7:Pure white
8:Pure blue
T: 6V
B: 24V
F: 110V
N: 230V
Q: 380V
2: AC/DC
4: AC
Reference
Dimension
LAY811D3*4
LAY811D4*4
LAY811D5*2
LAY811D6*2
LAY811D7*2
LAY811D8*2
10: 1NO
01: 1NC
DZS: Maintained
(Illuminated)
20: 2NO
02: 2NC
11: 1NO+1NC
3: Green
4: Red
5: Yellow
6:Blue
7:Pure white
8:Pure blue
T: 6V
B: 24V
F: 110V
N: 230V
Q: 380V
2: AC/DC
4: AC
LAY811DZS3*4
LAY811DZS4*4
LAY811DZS5*2
LAY811DZS6*2
LAY811DZS7*4
LAY811DZS8*4
01: 1NC
20: 2NO
02: 2NC
11: 1NO+1NC
DS:Waterproof
(Illuminated)
3: Green
4: Red
5: Yellow
6:Blue
7:Pure white
8:Pure blue
T: 6V
B: 24V
F: 110V
N: 230V
Q: 380V
2: AC/DC
4: AC
Industrial Control
Components
10: 1NO
LAY811DS3*4
LAY811DS4*4
LAY811DS5*2
Note:Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V
The pure white and pure blue are only available for LED lamp.
201
LAY8 Pushbutton Switches
Standard: IEC 60947-5
Order Information
Unit: MM
Base
Name
LAY8
Type
BE Auxiliary contact
Industrial Control
Components
202
Contact
101: 1NO
Reference
LAY8BE101
102: 1NC
LAY8BE102
103: 2NO
LAY8BE103
104: 2NC
LAY8BE104
105: 1N0+1NC
LAY8BE105
Dimension
RT16 Fuse
Standard: IEC 60269
Function
RT16 fuse provide:
Protection of circuits against overload current
Protection of circuits against short-circuit current
Order Information
Fuse-link
RT16-00
Rate current In(A) Suitable fuse bases
2
RT16-00
Weight(g)
Reference
170
RT16002
4
RT16004
6
RT16006
8
RT16008
10
RT160010
12
RT160012
16
RT160016
20
RT160020
25
RT160025
32
RT160032
40
RT160040
50
RT160050
63
RT160063
80
RT160080
100
RT1600100
125
RT1600125
160
RT16-1
80
RT1600160
RT16-1
450
RT161100
125
RT161125
160
RT161160
200
RT161200
250
RT16-2
125
RT161250
RT16-2
660
RT162125
RT162160
200
RT162200
250
RT162250
300
RT162300
315
RT162315
355
RT162355
315
Industrial Control
Components
160
400
RT16-3
RT16180
100
RT162400
RT16-3
850
RT163315
355
RT163355
400
RT163400
450
RT163450
500
RT163500
630
RT163630
203
RT16 Fuse
Standard: IEC 60269
Order Information
Fuse Base
Rate current In(A)
Material
Weight(g)
Reference
RT16-00
160
Ceramic
200
RT1600ZT
RT1600ZS
Resin
RT16-1
250
RT161ZT
700
Ceramic
RT161ZS
Resin
RT16-2
400
RT162ZT
1150
Ceramic
RT162ZS
Resin
RT16-3
630
RT163ZT
1280
Ceramic
RT163ZS
Resin
Technical Data
Rated working current
2-630A
Rated operation voltage
500/660V
Rated breaking capacity
120KA(500V), 50KA(660V)
Accessory-puller
Industrial Control
Components
204
Material
Usage
Reference
ABS(frame resistance)
Assemble and replace RT16 fuse
RT16C
RT16 Fuse
Standard: IEC 60269
Overall Dimensions
Unit: mm
RT16-00
RT16-1
RT16-2
RT16-3
a
78.5
135
150
150
b
29
48
58
67
c
57
62
72
85
d
49
67
67
67
e
6
6
6
6
A
30
58
64
64
B
120
200
250
250
C1
61
83
99
105
C2
85
96
112
120
D
100
175
200
210
E
25
25
25
25
F
7.5
10.5
10.5
10.5
30
30
30
G
Industrial Control
Components
Type
205
RT18 Fuse
Standard: IEC 60269
Function
RT18 fuse provide:
Protection of circuits against overload current
Protection of circuits against short-circuit current
Order Information
Cylindrical Fuse
Rate current In(A)
Weight(g)
Reference
RT18-32
2
8
RT1810382
RT18-63
Industrial Control
Components
206
4
RT1810384
6
RT1810386
8
RT1810388
10
RT18103810
12
RT18103812
16
RT18103816
20
RT18103820
25
RT18103825
32
RT18103832
2
20
RT1814512
4
RT1814514
6
RT1814516
8
RT1814518
10
RT18145110
12
RT18145112
16
RT18145116
20
RT18145120
25
RT18145125
32
RT18145132
40
RT18145140
50
RT18145150
63
RT18145163
RT18 Fuse
Standard: IEC 60269
Order Information
Holder of fuse
Pole
Rate current
In(A)
Note
Weight
(g)
Reference
RT18-32X
1P
32
Material:Resin
82
RT1832ZXB
With Indicator
2P
RT1832Z2XB
3P
RT18-32
1P
RT1832Z3XB
Material:Resin
32
2P
82
RT1832Z2B
Without Indicator
3P
RT18-32X
1P
RT1832Z3B
Material:Nylon
32
2P
82
With Indicator
1P
RT1832Z3X
Material:Nylon
32
2P
82
1P
RT1832Z3
Material:Resin
63
2P
206
With Indicator
1P
RT1863ZXB
RT1863Z2XB
3P
RT18-63
RT1832Z
RT1832Z2
Without Indicator
3P
RT18-63X
RT1832ZX
RT1832Z2X
3P
RT18-32
RT1832ZB
RT1863Z3XB
Material:Resin
63
2P
Without Indicator
3P
206
RT1863ZB
RT1863Z2B
RT1863Z3B
Technical Data
2-63A
Rated operation voltage
380V
Rated breaking capacity
100KA
Industrial Control
Components
Rated working current
207
RT18 Fuse
Standard: IEC 60269
Overall Dimensions
Unit: mm
Cylindrical Fuse
Type
Size
L
C
Hmax
RT18-32
10×38
38±0.6
10.3±0.1
10.5
RT18-63
14×51
51 +0.6
-1.0
14.3±0.1
13.8
Holder of fuse
Industrial Control
Components
208
Type
A
B
C
D
E
F
G
RT18-32
63
60
79
35
80
18
54
RT18-63
78
76
103
35
110
25
75
CCF Series Cable Connector
Technical Data
Thread specification: International metric standard
Material: Nylon 66
Working temp.: -40℃~+100℃
Max temp. in short time: +120℃.
Installation: Standard threaded hole
Colour: Black & gray
Order Information
Cabel
range (mm)
Thread external
diameter (mm)
Panel hole
(mm)
Thread
length (mm)
Spanner size
A&F
Reference
Black
Gray
7.6-4.6
12
12.5
8.5
18/19
CCFMG12IP68B
CCFMG12IP68W
10-6
16
16.5
15
22/22
CCFMG16IP68B
CCFMG16IP68W
14-9
20
20.5
15
27/27
CCFMG20IP68B
CCFMG20IP68W
18-13
25
25.5
15
33/33
CCFMG25IP68B
CCFMG25IP68W
25-18
32
33
15
41/41
CCFMG32IP68B
CCFMG32IP68W
30-24
40
41
20
50/50
CCFMG40IP68B
CCFMG40IP68W
41-30
50
51
22
62/62
CCFMG50IP68B
CCFMG50IP68W
51-40
63
64
25
75/75
CCFMG63IP68B
CCFMG63IP68W
7-3.5
7
12.5
8
17/19
---
B
CCFPG7IP54W
8-4.5
9
15.2
8.5
22/19
---
B
CCFPG9IP54W
10.5-6
11
18.6
9
24/22
---
12.5-7.5
13.5
20.4
9.6
27/24
14-8.5
16
22.5
10
30/27
18-12.5
21
28.3
12
36/33
---
CCFPG21IP54W
25-18
29
37
15
46/41
---
CCFPG29IP54W
30-23
36
47
15
57/50
---
CCFPG36IP54W
39-30
42
54
15.5
64/62
---
CCFPG42IP54W
45-35
48
59.3
15.5
70/65
---
CCFPG48IP54W
--C
---
CCFPG11IP54W
B
B
CCFPG135IP54W
CCFPG16IP54W
Industrial Control
Components
209
Industrial Plugs&Sockets Overview
CDPM Moving Industrial plugs
211
Pole: 2P+E~3P+N+E
Voltage:110~415V
Current:16,32,63,125A
CDP Fixed Industrial Plugs
212
Pole: 2P+E~3P+N+E
Voltage:110~415V
Current:16,32,63,125A
CDSM Moving Industrial Sockets
213
Pole: 2P+E~3P+N+E
Voltage:110~415V
Current:16,32,63,125A
CDSF Fixed Industrial Sockets
214
Pole: 2P+E~3P+N+E
Voltage:110~415V
Current:16,32,63,125A
Industrial Control
Components
CDPS Multi-function Plugs and Sockets
Pole: 2P+E
Voltage:110V, 230V
Current:16A
210
215
CDPM Moving Industrial Plugs
Standard: IEC 60309-1-2
Moving Industrial Plugs
16Amp
32Amp
a
b
63
67
63
CDPM463IP67
125
CDPM4125IP67
63
CDPM563IP67
125
CDPM5125IP67
5
125Amp
3
4
5
230 230 230
295 295 295
109 109 109
124 124 124
36 36 36
50 50 50
Industrial Control
Components
3P+N+E
CDPM3125IP67
a
b
c
4
400-415
3P+E
67
63Amp
3
125
67
CDPM363IP67
230-250
2P+E
PG
400-415
211
CDP Fixed Industrial Plugs
Standard: IEC 60309-1-2
Fixed Industrial Plugs
CDP316IP441
CDP332IP441
CDP316IP44
CDP332IP44
CDP416IP44
CDP432IP44
CDP516IP44
CDP532IP44
67
230~250
63
CDP363IP67
63Amp
67
400~415
63
CDP463196
3P+E
a
b
Industrial Control
Components
c
d
e
f
67
3P+N+E
212
400~415
63
CDP5631967
g
h
PG
3
193
122
157
109
19
6
288
127
29
4
193
122
157
109
19
6
288
127
29
5
193
122
157
109
19
6
288
127
29
CDSM Moving Industrial Sockets
Standard: IEC 60309-1-2
Moving Industrial Sockets
CDSM316IP441
16Amp
32Amp
4
5
3
4
5
Poles
3
a
130 131 139 149 149 154
b
66
76
90
90
90
100
a
67
CDSM3125IP67
63
CDSM463IP67
PG
125
CDSM4125IP67
63
CDSM563IP67
125
CDSM5125IP67
a
b
PG
63Amp
125Amp
3
4
5
240 240 240
3
4
5
300 300 300
112 112 112
36 36 36
126 126 126
50 50 50
400~415
213
Industrial Control
Components
3P+N+E
125
b
400~415
3P+E
67
CDSM363IP67
230~250
2P+E
67
63
CDSF Fixed Industrial Sockets
Standard: IEC 60309-1-2
Fixed Industrial Sockets
Pole No.
IP
44
Nominal
voltage(V)
3P+E
3P+N+E
44
44
16
CDSF316IP441
32
CDSF332IP441
16
CDSF316IP44
32
CDSF332IP44
16
CDSF416IP44
230~250
400~415
32
CDSF432IP44
230~400
16
CDSF516IP44
240~415
32
CDSF532IP44
63
CDSF363IP67
125
CDSF3125IP67
63
CDSF463IP67
67
3
4
5
3
5
5
a
128 128 129
b
86
90
96
97
97 104
M
25
25
25
25
25
141 141 143
25
230~250
Industrial Control
Components
67
230~400
63
CDSF4125IP67
CDSF563IP67
67
3P+N+E
240~415
125
CDSF5125IP67
125Amp
63Amp
Poles
400~415
125
214
32Amp
16Amp
Poles
44
2P+E
3P+E
Reference
110~130
2P+E
2P+E
Nominal
current(A)
3
4
5
3
4
5
a
193 193 193
220 220 220
b
122 122 122
140 140 140
c
157 157 157
185 185 185
d
109 109 109
130 130 130
e
19
19
19
17
17 17
f
6
6
6
8
8
8
g
270 270 270
320 320 320
h
130 130 130
150 150 150
PG
29
29
29
36
36 36
CDPS Multi-function Plugs&Sockets
Standard: IEC 60309-1-2
Multi-function Plugs and Sockets
1 Plug
1 Plug
1 Plug
1 Plug
Industrial Control
Components
215
Copper Terminal Block Overview
TB010
217
Hole:4, 6, 8, 10, 12, 14, 16
Hole diameter(mm):5.2, 6
Screw dimension(mm):M4*8, M5*10
Max current(A):100, 150
TB019
218
Hole:4, 6, 8, 10, 12, 14, 16
Hole diameter(mm):5.2, 6
Screw dimension(mm):M4*8, M5*10
Max current(A):100, 150
TB007
219
Hole:6, 8, 10, 12, 14, 16
Hole diameter(mm):5.2, 6
Screw dimension(mm):M4*8, M5*10
Max current(A):100, 150
TB043
220
Hole:78, 109, 116, 133
Hole diameter(mm):5~9
Screw dimension(mm):M4*8~M6*12
Max current(A):100~200
Industrial Control
Components
TB112
220
Hole:2x7, 2x15, 4x7, 4x11, 4x15
Hole diameter(mm):5.2
Screw dimension(mm):M4
Max current(A):125
216
TB010 Series Copper Terminal Block
Order Information
Industrial Control
Components
217
TB019 Series Copper Terminal Block
Order Information
Industrial Control
Components
218
TB007 Series Copper Terminal Block
Order Information
Industrial Control
Components
219
TB112 Series Copper Terminal Blocks
TB043 Series Copper Terminal Blocks
Order Information
65
132
65
132
Industrial Control
Components
220
DIN Rail Series
Order Information
Thickness(mm)
Reference
0.8
CDIN01E*
0.9
CDIN01N*
1.0
CDIN02T*
* means length
1000=1000mm
2000=2000mm
5000=5000mm
Overall Dimensions
Unit:mm
Industrial Control
Components
221
A Company to Serve You Where You Are
E-mail Address:info.OBD@delixi-electric.com
Algeria
Phone: +213 5 600 600 11
Chile
Phone:+56-2-4822100
Philippines / Laos / Bangladesh
Phone:+86 158 6807 8915
Colombia / Venezuela /
Ecuador / Peru / Bolivia
Phone:+57 3212056531
Russia / Kazakhstan
Phone: +7 916 693 59 84
Egypt
Phone:+20 10 011 3238 - +20 11 811 3546
Santo Domingo / Trinidad and
Tobago / Jamaica
Phone: +809 861 5803
Israel
Phone:+972 543311087
Kenya / Tanzania / Uganda /
Rwanda / Burundi
Phone:+97150 5536433
Malaysia
Phone:+601 93227688
222
Pakistan
Phone:+92 300 8465 789
Saudi Arabia / Yemen
Phone:+966-50 440 62 69
Turkey / Romania / Serbia / Bulgaria / Macedonia /
Montenegro / Albania / Moldova / Syria / Lebanon /
Jordan / Iran / Iraq / Central Asia
Phone:+90 5335256771
Morocco
Phone:+212 661 114 6999
UAE / Qatar / Oman / Bahrain / Kuwait
Phone:+97150 5536433
Nigeria / Ghana / Liberia
Phone:+234 8035059040
Vietnam / Cambodia
Phone:+8490 381 3973
Memo
223
Memo
224
Jan.2011

Similar documents