Quality - Proklima
Transcription
Quality - Proklima
Quality first of all Why ventilation? Pleasant and healthy living and working enviroment is not a privilage for chosen people. The importance of healthly living becomes vital in modern world. By using air handling units, ventilation and air-conditioning systems better living and working environment is easy to achieved. There are at least 3 basic reasons for using the ventilation devices : 1 Better air quality in room environment - by performing of air filteration , heating, cooling, humidifyication or dehumidifycation, the effects of noxious work enviroment («sick buildings») and air pollution are reduced. 2 Better control of air quality in room environment adjustment to space purposes, intensity of daily usage and customers needs. 3 Energy savings - reducing the energy costs, glass-house gases and irrational exploatation of fossile oil reserves. Quality and tradition For many years, company PRO-KLIMA is Croatian No 1 manufacturer of ventilation, air conditioning and heating equipment. Successful business cooperation with branch-leading European and worldwide companies represents best possible warranty for top quality products and services we are proudly offering to our local and worldwide customers. 2 4 5 basic reasons ... For choosing “PRO-KLIMA” Remarkable quality of products, functional and reliable equipment Active after sales services (startup, maintainance, repair, spare parts supply) 1 3 5 Flexible in fulfilment of customers needs ”Best buy” offering principle Devotion to constant improvement of business processes and relations with customers Together to success ■ More than 1300 satisfied customers in 40 years long period of business ■ More than 3000 facilities equipped with our products in more than 20 European and worldwide countries Tradition and quality Expert employees Full service Satisfied customers ■ More than 130 employees; 19 engineers and several branch experts Flexible resources ■ New office and production facility on more than 4800 m2 area ■ More than 6000 delivered units High quality products Respectable references Quality assurance High quality of our products and services is confirmed by several certificates (ISO 9001, CE, GOST, TÜV). Looking forward to do business with you. Always at Your service. Modular airhandling unit Type KU-M Air handling units designed in 25 different sizes cover the airflow volumes range from 800 to 190,000 m3/h. The combination of sizes and executions provides a maximum adaptability to ventilated space. Required cleanness, temperature and air humidity are ensured by filtration, heating, cooling, humidifying or drying the air. In most cases the air treatment process in air handling units is completely automatic. DAMPERS Dampers consist of a number of aluminium blades bordered with a rubber seal and built into a common aluminium frame. Manual blades activation is possible by a crank handle or by an electric-motor drive. It is also possible to build in a lever for simultaneous activation of blades of two dampers for the purpose of mutual airflow control or closing/opening of dampers. SOUND ATTENUATORS The unit is available in six different lengths, depending on the airhandling unit size. Buffles made of a special paper lined mineral wool are highly absorbing, moisture-proof and non-combustible according to DIN 4102 class A1. HONEYCOMB HUMIDIFIERS Humidification of air is provided by a contact between air and a large wet surface (honeycomb) which results in evaporation of water. The honeycomb is made of specially formed PVC fins with gaps which enables the flow of air. Water pours from the vessel on the top of the honeycomb down the walls to the receiver from which it is pumped back into the vessel on the top of the honeycomb. Whole range of air washers, water atomisers, steam generator humidifiers are also available (upon request). FILTERS Filter insert classes EU 1 to EU 9 are suitable for all systems and adjusted to unit size. Special filters such as active carbon filters, degreasing filters, compact filters, absolute filters class EU 10 – EU 14, etc. can be supplied on request. FRAME The casing structure consists of profiles and corner elements made of die cast aluminium alloy, powder coated to standard RAL colour or colour according to the customer’s request. FREQUE FREQUENCY FREQ UENC NCYY CO CONVERTER Motor speed regulation with a frequency converter. FANS Various types of radial double inlet centrifugal fans with forward or backward curved blades and plug-in fans are installed. Centrifugal fans with powder-coated wheel or fans and motors with an adequate protection (ATEX design) are used for air discharge with a high content of fatty vapours or explosive gases. A great number of types and sizes make it possible to select the most suitable fan for all specific requirements. HEAT RECOVERY UNITS By using the return air heat recovery, considerable energy savings of heating and cooling power may be achieved. The most often used types of recuperators are plate, rotating and multi-plate type. Plate recuperator is made of specially formed interconnected aluminium fins. The plate exchanger design completely separates the airflow, thus preventing the transfer of any impurity, smell, moisture, bacteria, etc. from the return to the fresh air. Ceiling air handling units Type KU-P Air handling units in 3 different sizes cover the air volume flow ranging from 500 to 4 000 m3/h. The devices are manufactured as single units on common baseframe. Due to very low installation height of 350 mm, units are suitable for installation under the ceiling or into the ceiling structure. The design and quality of units and built-in materials allow a carefree and quiet operation that meets the noise level requirements prescribed. Combinations of functional units that are frequently delivered are offered as standard configurations. SUSPENSION Unit is suspended on a ceiling with hangers and suspension elements (corners, profiles and hooks). FAN SPEED CONTROL Variable air volume flow control units. MAINTENANCE Access doors for fans and filters are installed on the bottom of the unit, and coil connections are installed on unit side, which enables easy access to installed components, as well as their mainteinance and replacement. Hygienic airhandling units Type KU-H Market research in Croatia and in the world clearly shows increasing needs for specially constructed devices for air-conditioning of cleanrooms, operating rooms, laboratories, pharmaceutical and electronic facilities. Following the world trends and needs of customers, our team of experts have constructed and offered to the market a new series of high-quality air-conditioning devices in hygienic design, which are in conformity with all valid standards and guidelines for design, manufacture, installation and maintenance of hygienic air handling units. During development, the major objectives were: ■ to apply only those materials that do not pose any threat to human health and do not facilitate the growth of harmful micro organisms ■ internal surfaces of the units must be made of wear-resistant materials and easily accessible for cleaning and desinfection purposes ■ all parts for air movement should allow easy inspection, cleaning and disinfection Hygienic air handling units are designed and manufactured in conformity with the following standards and guidelines: ■ EN 1886 – Ventilation for buildings – Air handling units – Mechanical performance ■ EN 13053 – Ventilation for buildings - Air handling units – Ratings and performance for units, components and sections ■ VDI 3803 – Air-conditioning systems - Structural and technical principles ■ VDI 6022 Part 1 – Hygienic standards for ventilation and airconditioning systems - Offices and assembly rooms ■ VDI 6022 Part 3 – Hygienic air conditioning; technical health requirements (VDI ventilation rules) ■ DIN 1946 Part 4 – Ventilation and air conditioning - Part 4: Ventilation in hospitals (VDI Ventilation rules) Certificates... Hygienic airhandling units, series KU-H, are certified by TÜV München standards for ventilation and air-conditioning systems in production facilities and business enterprises ■ DIN 1946 Part 2 – Ventilation and DIN 1946-4 VDI 6022 EN 13053 Swimming pool airhandling units Type KU-B Climatic conditions within the area of indoor swimming pools are highly demanding. Pursuant to VDI 2089 the condition of air maintained within the swimming pool area must be suitable for both the visitors and the building structure. This is possible by means of standard units for saturated warm air exhaust and fresh dry air supply, which is accompanied by a considerable energy consumption despite the use of a recuperator. The air handling units of the KU-B series, equipped with a plate recuperator with an exhaust air heat utilization exceeding 60% and a heat pump complete with the accessories and controls, guarantee the achievement of microclimatic conditions suitable for both the people and the building structure. Due to various conditions resulting from a varying intensity of using the swimming pool, a varying condition of the outdoor air during the day, as well as during various seasons of the year, the design of the air handling unit enables five different modes of operation at minimum operating costs. Control switchboxes are delivered with all necessary elements of DDC controller and components of electrical installation (bimetals, relays, control switches). DAMPERS The system of dampers allows the change of the operation mode. They are made of counterflowconnected aluminium blades equipped with rubber seals. The automatic operation of dampers is servomotor-controlled. For the additional protection the external and internal sides of the unit are powder coated. Unit design allows a simple handling and maintenance, including the replacement of components. HEAT PUMP Heat pump system consists of a condenser, evaporator, compressor and of the accessories connected, tested and ready for automatic operation. Environmental friendly refrigerants are used. Modes of operation The DDC automatic controls used for the unit operation and control provide all air handling unit functions: [1] Initial operation for rapid heating of space in winter (100% recirculation) ■ ambient temperature and air humidity control; ■ supply and exhaust fan operation management; ■ heat pump operation control; ■ pressure drop monitoring due to filter impurities; [2] Operation in the standstill mode (no swimmers) ■ damper operation management; ■ water heater operation control and antifreeze protection; ■ possibility of connecting to the central control or building management system (BAS); ■ modem connection for the purpose of remote control. [3] Operation at winter use of swimming pools [4] Operation when using swimming pools in transitional periods [5] In the summer period the heat pump is out of operation and the 100% fresh air is used. Air heaters Type TR Air heaters are used for quick and efficient heating of large spaces. Advantage of these device is direct heating of air with burn gases through the heat exchanger, by which the heat loss for heating up intermediate medium – water is avoided. Efficiency of fuel energy is more than 90 %, which complies with standards and regulations of EU. Such benefits are result of intensive research of air flow, burner gases and apply of new compounds. Quality of device and installed components (fans, electric switches, burner, etc.) guarantee long lasting and fault-free operation. Main characteristics ■ Low investment costs ■ Small fuel and electricity consumption ■ Fast achievement of pre-set working temperatures ■ Efficient ventilation of working spaces in summer period ■ Moderate air temperatures pleasant for people, animals and plants ■ Possibility to use as an additional heating system ■ Quiet operation ■ Quick and simple installation of unit and accessories ■ Steady construction ■ Fuel-OIL or GAS Control switchbox Type RO-KU and regulation Control switchboxes are delivered with all necessary elements of DDC regulation and electrical components (bimetals, relays, control switches). Construction of control switchboxes, selection of appropriate components and preparation of technical documentation are done with usage of modern technologies and up-to-date computer applications. Measured and adjustable values, status and alarms are possible to read on digital screen on front side of DDC controller. Control switchboxes are completely wired and tested, with all necessary certificates. Services DESIGN AND CONSULTING Our sales and technical support personnel will gladly help you and advise you in choosing of equipment and designing of ventilation systems. START-UP For correct unit operation it is necessary to make correct connection of all components, set-up of parameters and automatic regulation options and fulfil the start-up procedure. Our personnel is trained for all these jobs. SERVICE Fault diagnostics and trouble shooting on equipment is ungrateful job which demands professional skills. Finding of new adequate parts takes time. Costs of device malfunction could make several problems for work of other processes. Our service personnel can help you to overcome such problems and faults on equipment, any time and anywhere. MAINTEINANCE Safe and long lasting operation of devices depends on schedule and quality of maintenance. Allow our personnel to take care of maintenance of your devices. Choose the model, schedule and range of maintenance that best fits your needs. SPARE PARTS All consumable parts which need to be changed periodicaly (filters, belts etc.) as well as all the other main parts (fans, motors, coils etc.) can be supplied by us. We offer original and high quality spare parts. SHEET METAL TREATMENT AND POWDER COATING • Designing • 3D CAD-programming • Technological preparation • Consulting • Build-up of technical documents • Machine processing (cutting, bending, punching, notching) • Finishing (riveting, welding, boring, spot welding) • Parts assembly • Splashing polyester powder by using GEMA dispersion device Unit selection software AIRCALC++ Unit selection software AIRCALC++ enables easy and quick selection of appropriate size, type and configuration of unit, according to requested parameters and conditions. Great variety of options and printouts will ease and speed-up the process of unit construction and offer a lot of precious and needed unit data (technical data, noise levels, fan curves, dimmensions, weights etc.) Few steps needed for complete airhandling unit calculation ... 1 Data input 2 Size selection Installation of AIRCALC++ unit selection software possible from our CD Catalog For help and assistance during installation and application usage please contact our sales department freely H-x diagram, noise levels and fan characteristic curves 3 Components and unit dimmensions calculation Data printouts: technical data, unit drawing and detailed unit description References Shopping centers City Center One, Zagreb-Jankomir, Croatia Interspar, Zadar, Croatia Mercatone-Emmezeta, Osijek, Croatia Konzum and Superkonzum, Croatia Avenue Mall, Zagreb, Croatia Shopping center Ural, Ekaterinburg, Russia HOTO Business tower, Zagreb, Croatia HG SPOT, Zagreb, Croatia Zagreb tower, Zagreb, Croatia Coca Cola, Zagreb, Croatia Policlinic Sunce, Zagreb, Croatia Business center 2000, Zagreb, Croatia Business buildings Complete reference list you can download from our Web site www.proklima.hr Hotels Hotel “Le Méridien Lav”, Podstrana-Split, Croatia Hotel “Antunović”, Zagreb, Croatia Hotel “Ambasador”, Opatija, Croatia City pool, Dubrovnik, Croatia Hotel “Sol Garden Istra”, Umag, Croatia City hospital, Gubkinskij, Russia Children hospital, Volgograd, Russia Printing mill VJESNIK, Line Polyman 45, Zagreb, Croatia Car factory VAZ, Togliatti, Russia Pools City pool, Varaždin, Croatia Hospitals KBC Rebro annexes, Zagreb, Croatia Industrial facilities TDR Tobacco factory, Kanfanar, Croatia For more information, visit our web page www.proklima.hr Gradna 78e, HR-10430 Samobor, Croatia Phone: +385 1 6546 343, Fax: +385 1 6546 344 proklima@proklima.hr www.proklima.hr PB-OK-09-ENG Manufacturing and installation of ventilation, airconditioning and heating equipment
Similar documents
PRO-KLIMA product range V14
• Technical data file build-up • Machine processing (cutting, bending, punching, notching)
More information