SYNCRO AS-2M4 Brochure
Transcription
SYNCRO AS-2M4 Brochure
WWW.INCITEFIRE.COM.AU SYNCRO AS 1-2 LOOP SYSTEMS Syncro AS Key Features Analogue Addressable Fire Control Panels (1 or 2 Loops) * The Syncro has wireless options * The Syncro can be networked - why have one large panel ? Did you know ? * The multisensor can operate as 2 detectors : smoke local and heat all. * The sounder base has 51 tones and 8 can be operated from the panel Why use OWS? * There is a modem for remote access to the Syncro Standard Features Product Overview • Approved to AS7240.2 and AS7240.4 The Syncro AS addressable control panel is designed to meet the requirements of AS7240.2, AS7240.4 • Available in 1 or 2 loops and networkable up to 64 panels with up to 500 zones per network (the perfect solution for small and large solutions) Available in 1 or 2 loops and networkable up to 64 panels with up to 500 zones per network (the perfect solution for small and large projects) • 127 devices per loop / Up to 800 sub addressable The Syncro AS is capable of driving a full loop of sounders @ 85dB • LCD display & 16 zone LED indication • Compatible with Hochiki ESP detectors and modules • Open protocol, non-proprietary software • ActivFire listed AFP-2761 • System enabled with 003 key Housed in the same installer friendly and attractively styled enclosure as the Sigma CP (conventional) and Sigma XT (extinguishant) range of control panels, the Syncro AS combines compact and practical styling with the programming power and connectivity normally associated with much larger systems • Optional OWS available - 20,40,60,120 • Optional fan control available • Capable of driving a high number of loop powered sounders • Base cabinet size 385W x 520H x 110D (mm) • Range of cabinet sizes available Other Features * Standard or Deep cabinet options Config Features * Comprehensive day/night mode facility * Programmable one touch test mode * Powerful and versatile cause & effect programming * Cause and effect wizard including: * Cause and effect action * Disablement configuration * Test mode configuration • 16 zonal LED indicators • 5 preconfigured digital inputs • Easily configured using Loop Explorer software • Up to 32 RS485 expansion modules per panel 42 QLD 07 3252 5366 NSW 02 9644 7144 New Features * Hotel Mode * AAF * Non latching detectors * Non fire attributes: Detector options for system control only VIC 03 9544 2211 SYNCRO AS 1-2 LOOP SYSTEMS WWW.INCITEFIRE.COM.AU Technical Specifications Overall size (std) 385W x 520H x 110D (mm) FinishEpoxy powder coated Colour - lid & box BS 00 A 05 grey - fine texture Colour - controls plate & labels RAL 7047 light grey - satin Supply voltage 230V AC +10%/-15% (100 Watts maximum) Mains supply fuse 1.6 Amp (F1.6A L250V Operating voltage 18 to 30 volts DC Battery charging circuit impedance Rimax 1.35R Min ouput current for correct operation Imin 130mA Max ripple current 1.5 +/- 0.3V Battery typesealed lead acid Aux 24V output rating 300mA maximum load (fused at 500mA) Sounder output rating (2 outputs) Each rated at 1A Relay contacts30VDC, 1A maximum Fault contact rating Local fire contact rating Fire contact rating 30V DC 1 Amp 30V DC 1 Amp 30V DC 1 Amp Panels SYNCRO AS-1M3 Syncro AS 1 Loop in M3 Cabinet (385W x 520H x 110D) SYNCRO AS-1M3TD Syncro AS 1 Loop in M3 Cabinet (385W x 520H x 110D) SYNCRO AS-1M4TD Syncro AS 1 Loop in M4 Cabinet (385W x 700H x 200D) SYNCRO AS-2M3TD Syncro AS 2 Loop in M3 Cabinet (385W x 520H x 110D) SYNCRO AS-2M4TD Syncro AS 2 Loop in M4 Cabinet (385W x 700H x 200D) Cabinet Options M3 Cabinet • 385W x 520H x 110D (mm) • 2 viewing / control apertures • Lockable window door available M3D Cabinet • 385W x 520H x 200D (mm) • 2 viewing / control apertures • Lockable window door available M4 Cabinet • 385W x 700H x 200D (mm) • 3 viewing / control apertures • Lockable window door available Flush surround available for all cabinets QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 43 WWW.INCITEFIRE.COM.AU METALWORK OPTIONS Metalwork Options For Sigma and Syncro Systems Product Overview All the metalwork options available are designed to match and complement the complete range of SigmaCP, SigmaXT & SyncroAS control panels. The 19” rack mount is particularly ideal for use in a combined FIP / QE90 EWIS panel or when fitting in IP rated enclosure. It houses and supports the entire FIP on a fully hinged swingout frame constructed of welded steel for strength and powder coated to match the fitted panel. The flush surrounds are available for all cabinet sizes and warning signs. They are designed to complement the look of the entire range of cabinets. All the flush surrounds are easy to install, are constructed of welded steel and powder coated to match the fitted panels. The ASE brackets are custom made for ROMTEK & CENTAUR alarm signalling equipment. They are finished in light grey satin, to match the entire range Sigma and Syncro panels. KM - FS-M2 Flush Sourround M2 Flush Surround • 415W x 340H x 15D (mm) • Cutout - 385W x 310H (mm) • Fascia width - 15mm KM - FS-M3 M3 Flush Surround • 415W x 550H x 15D (mm) • Cutout - 385W x 520H (mm) • Fascia width - 15mm KM - FS-M4 M4 Flush Surround • 415W x 730H x 15D (mm) • Cutout - 385W x 700H (mm) • Fascia width - 15mm KM - FS-WS 44 QLD 07 3252 5366 NSW 02 9644 7144 Flush surround also available for warning signs VIC 03 9544 2211 WWW.INCITEFIRE.COM.AU METALWORK OPTIONS 19’’ Rack Mount • Available for M2 and M3 size cabinets • Houses the complete panel for rack mounting • Fully hinged to swing out complete panel • Robust fully welded steel construction • Epoxy powder coated to match panel coulour • Ideal for QE90 combination panel * Mounting information into 19” IP rated enclosure KM -HS-M2-9RU M2 M2 19” Hinged sourround KM-HS-M3-13RU M3 M3 19” Hinged sourround ASE Brackets • Available for ROMTEK and CENTAUR • Light grey satin finish to suit other modules • Fits neatly into viewing aperture KM -ASE-RT • Suitable for use in M3 and M4 size cabinets • Mounts ASE to be flush KM -ASE-CT QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 45 WWW.INCITEFIRE.COM.AU SYNCRO CABINET OPTIONS Cabinet Options Product Overview Constructed of 1.2mm sheet steel and finished with light grey epoxy powder coating, our range of cabinets are designed to be aesthetically pleasing and functional. The viewing or control apertures provide a fully modular system for fitting of equipment such as manual call point, fan controls, OWS controls, ASE and other equipment. An ample number of knockouts for cable entry are provided on the rear, top and sides of the cabinets, and their lightweight construction makes installation easy. Lockable window doors are available for the M3 & M4 size cabinets, providing an extra level of protection against tampering. Flush surrounds are available for all 3 cabinet sizes & hinged 19” rack mounts are available for the M2 & M3 cabinets Range M2 Cabinet • 385W x 310H x 90D (mm) • 1 viewing / control aperture • Also available in M2D - 110mm deep M3 Cabinet • 385W x 520H x 110D (mm) • 2 viewing / control apertures • Also available in M3D - 200mm deep • Lockable window door available M4 Cabinet • 385W x 700H x 200D (mm) • 3 viewing / control apertures • Fault indicator - Yellow LED • Lockable window door available * Flush surround available for all cabinets Technical Specifications Construction1.2mm mild sheet steel FinishEpoxy powder coated Colour - lid & box BS 00 A 05 grey - fine texture Colour - controls plate & labels RAL 7047 light grey - satin IP rating30 Locks 1 lock on M2, 2 locks on M3 & M4 Keyed003 46 QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 WWW.INCITEFIRE.COM.AU SYNCRO CABINET OPTIONS Industrial Cabinet Features Standard Cabinet • Various sizes available to suit application • 1.6mm thick zinc coated steel • Powdercoated finish • Polycarbonate viewing window • Protection rating IP 66 Stainless Steel Cabinet • Various sizes available to suit application • 1.6mm thick 316 stainless steel • Polycarbonate viewing window • Protection rating IP 66 * Optional 003 keyed lock for any cabinet * 3 point locking on larger cabinets * Polyurethane gasket foamed in place * Guttered door opening Technical Specifications Construction (standard) 1.6mm Zinc coated steel (corrosion resistant) Finish (standard) Epoxy powder coated - RAL7032 Construction (s/steel) 316 Stainless steel Finish (s/steel) N4 surface finish (eliminates ‘tea staining’) LockSquare key multi point locking mechanism KeyedOptional 003 keyed lock GasketFixed polyurethane gasket QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 47 WWW.INCITEFIRE.COM.AU OCCUPANT WARNING CONTROL & FAN CONTROLS Occupant Warning Control Product Overview The Incite occupant warning system control module has been designed to enable an easy interface of the Sigma and Syncro fire control panels to Evactron or Tgen amplifiers, and to provide paging and manual control facilities. The module is supplied on a carrier plate suitable for ease of fitting neatly into a Sigma or Syncro control panel. The SOWC is secured from unauthorised operation via a 003 keyswitch. It has test and PA buttons, alarm and fault LED’s, and an inbuilt microphone. Features • Fits the standard Syncro AS & Sigma cabinet carrier plate • Secure access to the control via standard 003 Key switch • Alarm and Fault indicators • High quality Inbuilt panel microphone EVAC-SD-OWC • Compatible with Evactron 20,40,60,120 OWS AMPS • Compatible with Tyco TGEN50 OWS AMPS • Quick and easy to fit Fan Control Module Product Overview The Incite SyncroAS fan control module (SFCM) has been designed to enable ease of interface to building services providing smoke control in an installation. The SFCM manual controls will only operate when the enable keyswitch on the SyncroAS panel is in the enable position. The SCFM contains 3 off 1668 control and status indicators, a general fire trip and isolate, and a lamp test button. The module connects to the SyncroAS panel by four wires, two for power and two for RS485 communications. Features • Contains 3 x AS1668 controls • Connects directly to SyncroAS RS485 data bus • Auto - fan on and fan off modes SYNCRO-KAU2016 • Configurable through SyncroAS control panel or via a PC with Loop Explorer software • Provides seamless fan control integration with SyncroAS panels • Interfaces SyncroAS control panel to the duct detectors ANC Control Features • Enables ease of interfacing to building services providing mual control & indication in an installation • Controls enabled by the keyswitch on the Syncro AS panel • 4 push button controls, 8 LED indicators & 3 clean contact relays • Simple 4 wire connection to the Syncro AS panel, 2 for power, 2 for RS485 SYNCRO-K556 48 • the ANC control may be mixed on the RS485 bus with other expansion/control devices QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 WWW.INCITEFIRE.COM.AU DOCBOXES DocBox Product Overview Another addition to the range, the document box is designed to complement the design and colour of the Sigma and Syncro range of control panels. The document box will hold up to 100 sheets of A4 documents or log books. The “DocBox” also doubles up as a key box providing 7 (M2) or 14 (M3) easily accessible key hooks inside the enclosure. Features • Matches design and colour scheme for standard Sigma and Syncro control panel range • Easy to install • Key lockable • Designed for versatility • Holds A4 size documents and Log books • The document box also doubles as a key box providing 7 (M2) or 14 (M3) easily accessible key hooks inside Sigma-M2-DocBox Sigma-M2-DocBox Sigma-M3-DocBox Technical Specifications Size (M2) 385W x 310H x 90D (mm) (M3) 385W x 520H x 110D (mm) Construction 1.2. mild steel sheet Colour BS 00 A 05 grey - fine texture Weight 3Kg Lock type 003 Document space A4 (M2) A3 (M3) No of key spaces 7 (M2) and 14 (M3) QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 49 WWW.INCITEFIRE.COM.AU SYNCRO IO Syncro IO 16 channel input /output board Syncro-K560 Product Overview Standard Features To add more I/O capability to the extensive options already offered by the Syncro control panel, up to thirty two, 16 channel I/O boards may be connected. * 16 channels The 16 channel boards may be mixed on the RS485 bus with 8 way sounder boards, 6 way sounder boards or 4 way conventional detection zone boards to provide a very flexible system of I/O to satisfy any requirement. * Each channel configurable as input or output * Inputs opto-isolated * Outputs open collector transistor * Simple 2 wire connection to control panel Up to 32 boards supported per panel When using a simple two wire RS485 communications protocol, these boards may be mounted locally to the control panel or distributed on a bus up to 1200 metres long by using a suitable cable. * (512 Input/Output Channels) The flexibility of these boards is further enhanced by the fact that each of the channels is configurable as either an input or an output. * Multi drop RS485 communications can be used with other Syncro I/O modules on the same panel * Inputs and outputs configurable as per field devices * Full cause and effects on all inputs and outputs * Compatible with Syncro AS panels Each channel may also be configured to produce a variety of input actions or respond to a variety of output types. All channels can contribute to, or respond to, system wide cause and effects logic. Typical uses for I/O boards include geographical LED mimic displays and plant alarm inputs. Standard Syncro control panels contain fixings for one sounder, relay, conventional detection or I/O board, which can easily be connected using four small signal wires to the power and comms bus within the panel. Consideration must be taken as to the loading on the main panel. 50 QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 WWW.INCITEFIRE.COM.AU SYNCRO IO Technical Specifications Product codeSYNCRO-K560 Supply voltage 21 - 30V DC Quiescent current consumption 20mA Weight1kg Current per input3mA (maximum) Current per output100mA (maximum) CommunicationsRS485 two wire Maximum distance from panel 1.2Km (using correct type of cable) PCB size190mm x 61mm Cable capacity2.5mm per terminal Operating temperature -10°C to +50°C Operating humidity To 95% (non condensing) QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 51 WWW.INCITEFIRE.COM.AU SYNCRO IO Syncro IO 4 way conventional Detection Zone Module Syncro-K545 Product Overview Standard Features To further enhance the versatility of the Syncro fire alarm system, four conventional detection circuits can be connected with up to 30 detectors per circuit. * 4 monitored detection zone inputs Conventional control panels can be replaced with this simple module and existing conventional systems can be interfaced directly to modern analogue addressable control systems and networks. A fail safe mode ensures that the detection inputs will still operate the sounder outputs and fire contact if communication to the Syncro panel is lost. * 2 monitored sounder outputs * Volt free fire contact * Local power supply fault input * RS485 comms connection to Syncro Fire Alarm Panel * Individual fault and operated indications for inputs and outputs * Directly replaces a conventional control panel when integrating into an analogue addressable system Up to 32 of these boards can be connected to the dedicated RS485 communications bus in the control panel giving the capability of up to 128 conventional zones with 64 sounder outputs. * Can be used with other Syncro I/O modules on the same panel The detection zone boards may be mixed on the RS485 bus with 16 channel I/O Boards, 6 way sounder boards or 8 way relay boards to provide a very flexible system of I/O to satisfy any requirement. * Compatible with Hochiki range of detectors. For any other brands please contact Incite Fire. * Compatible with Syncro AS panels All inputs and outputs are configurable in the same way as devices connected to the loops and all may be acted upon by cause and effect logic. Standard Syncro control panels contain fixings for one (four way) Detection Zone board, Sounder board, Relay board or I/O board, all of which can easily be connected using four signal wires to the power and comms bus within the panel. Consideration must be taken as to the loading on the main panel. 52 QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 WWW.INCITEFIRE.COM.AU SYNCRO IO Technical Specifications Product codeSYNCRO-K545 Supply voltage range 21 to 30 volts DC Quiescent current consumption 70mA Weight1kg Operating current (all outputs on) 250mA Output contact rating 30V DC 1 Amp Detection zone monitoring resistor 6k8 Sounder circuit monitoring resistor 10k CommunicationsRS485 two wire Max. distance from panel 1.2Km (using RS485 data cable) PCB size190mm x 74mm Fixing centres51.5mm x 180mm Cable capacity2.5mm per terminal Operating temperature -5°C to +50°C Operating humidity To 95% (non condensing) QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 53 WWW.INCITEFIRE.COM.AU PSU - SWITCH MODULE POWER SUPPLY/CHARGER PSU Approved Switch Mode Power Supply/Charger PS-406 (5 AMP) PS-408 (10 AMP) Product Overview PS-408 Standard Features The PS407-PS408 power supply/battery charger has been developed using switched mode technology to produce an efficient and lightweight power unit for a host of fire alarm applications. * Complies with AS7240-4 Suited to almost any application, the PS407-PS408 is designed to be a universal power source which will reduce spares stock holding and increase serviceability of systems. The comprehensive monitoring features of the PS407-PS408 include true battery present detection, low battery voltage warning, battery overcharge warning, high battery impedance monitoring and low battery shut off. These features combined with the temperature compensated charger output will increase the service life of sealed lead acid batteries. * Fully enclosed construction * Small and lightweight * True 10 Amp continuous output * Comprehensive fault monitoring * Temperature compensated charger * Wide input supply voltage * Low battery shut off to prevent deep discharge of battery PS-406 Standard Features * Complies with AS7240-4 * Fully enclosed construction * Small and lightweight * True 5 Amp continuous output * Comprehensive fault monitoring * Microprocessor controlled * Temperature compensated charger * Wide input supply voltage * Low battery shut off 54 QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 PSU - SWITCH MODULE POWER SUPPLY/CHARGER WWW.INCITEFIRE.COM.AU Technical PS-408 (10 Amp) Construction Finish Epoxy powder coated Colour Black Size 260mm x 120mm x 65mm Weight 2Kg Supply voltage 230V AC (+10%/-15%) Output voltage 24V DC Total output current 10.25 A Battery charge current 2.25 A Load Current 8.0A (with flat battery) Fault outputs rating 50mA max. Mains fuse 5 Amp 20mm HRC Load fuses 10 Amp (self resetting) Mains failed warning Switched -ve output Battery disconnected warning Switched -ve output Battery low warning Switched -ve output Battery overcharge warning Switched -ve output Earth fault warning Switched -ve output Common fault output Switched -ve output Operating temperature -5 to +50 deg. C Technical PS-406 (5.25 Amp) Construction Aluminium base - sheet steel cover Finish Epoxy powder coated Colour Black Size 226mm x 120mm x 55mm Weight 0.9Kg Supply voltage 230V AC (+10%/-15%) Output voltage 24V DC Total output current 5 Amps (continuous) Battery charge current 1.25 Amps max. Load current 4.0 Amps (with flat battery) Fault outputs rating 50mA max. Mains fuse 3 Amp 20mm HRC Load fuses 5 Amp (self resetting) Mains failed warning Switched -ve output Battery disconnected warning Switched -ve output Battery low warning Switched -ve output Battery overcharge warning Switched -ve output Earth fault warning Switched -ve output Common fault output Switched -ve output Operating temperature -5 to +50 deg. C QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 55 WWW.INCITEFIRE.COM.AU PSU - FIRE POWER SUPPLIES PSU Approved Fire Alarm Power Supplies PS 407-M2D ActivFire #: AFP 2793 PS 406-M3 Product Sizes PS407 = PSU S407 - 24V - 2.5Amp Power Supply PS407-M2D= 24V-2.5A PSU CABINET, UP TO 12AH (385W X 310H X 110D) PS407 PSU-S407 = PSU S406 - 24V - 5.25Amp Power Supply PS406-M3 = 24V-5.25A PSU CABINET, UP TO 22AH (385W X 520H X 110D) PS406-M3D= 24V-5.25A PSU CABINET, UP TO 26AH (385W X 520H X 200D) PS408 = PSU S408-24V@10 Amp Powersupply PS408-M3D= 24V-10.25A PSU CABINET, UP TO 45AH (385W X 520H X 200D) Product Overview Power supplies provide a stable and fully regulated, true 24V output for fire alarm system applications under all power conditions. The unique regulation techniques ensure that even when running on standby batteries, a stable 24V supply is available to all parts of the system ensuring that all 24V powered devices connected are supplied with optimum power. The powerful onboard micocontroller ensures that all battery types are conditioned with optimum, temperature compensated charging algorythms to maximise battery life and maintain batteries in top condition. Standard Features * 2.5A, 5.25A and 10A versions * Chassis only or enclosure mounted with battery space * 110V or 240V input * Regulated, true 24V output * Intelligent battery charging and temperature compensation * House up to 26Ah batteries * Status indicators for monitored faults Enclosed units are available to match both Sigma and Syncro equipment ranges and all are finished with matching livery and provide power on and power fault indications. * Dual output option for powering fire alarm control panels remotely * Chassis versions have same mounting points * Fully enclosed and robust construction * Approved to A7240-4 56 QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 WWW.INCITEFIRE.COM.AU PSU - FIRE POWER SUPPLIES Technical Specifications Construction 1.2 mild sheet steel IP Rating IP30 Finish Epoxy powder coated Colour - lid & box BS 00 A 05 grey - fine texture Mains input supply voltage 240V AC 50/60Hz or 110V AC 50/60Hz (link selectable) Mains supply fuse 250V, 3A, SB, 5mm X 20mm Load output voltage 19- 30V DC +/- 1% Maximum ripple 1 Volt Load fuse 5 Amp, self resetting Polyfuse Maximum current draw 5 Amps from batteries Battery charge output voltage 27.4V DC nominal at 20 degrees C (temperature compensated from -5 to 45 degrees C Battery charge current Two stage, constant voltage. 1.25 Amps maximum Deep discharge prevention Battery disconnects at 19V Operating temperature -5 to 45 degrees C Common fault output Normally energised volt free changeover relay – 30V DC 1 Amp Battery disconnected output Open collector 50 milliamps Battery low output Open collector 50 milliamps Charger fault output Open collector 50 milliamps Earth fault output Open collector 50 milliamps Mains failed output Open collector 50 milliamps Fault output connector 14 way DIL header 0.1” spacing Mains connector 3 way terminal, 7.62mm spacing, 2.5mm maximum cable size Load connector 2 way terminal, 7.62mm spacing, 2.5mm maximum cable size Battery connector 2 way terminal, 7.62mm spacing, 2.5mm maximum cable size Front panel Power On indicator Green LED Front panel Fault indicator Yellow LED QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 57 WWW.INCITEFIRE.COM.AU Syncro AS Analogue Addressable Fire Control Panels Networkable SYNCRO AS LARGE SYSTEMS For large projects there is the option of networking Syncros in one enclosure to provide addressable loops. Networking The flexibility of the SyncroAS system can be further enhanced by connecting up to 64 control panels together on a high integrity network. A simple two wire connection between each panel allows events to be transmitted to other parts of the system to provide indication or control on a system wide basis. Using the Loop Explorer configuration software, up to 64 nodes can be programmed to respond in a variety of ways to any system events as required. This flexibility extends the comprehensive cause and effect programming capability of SyncroAS panels to the entire network allowing actions, test modes or disablements to be started from any point. The fault tolerance of the network is such that any single open or short circuit fault will not result in any loss of information. Multiple faults are isolated and the network breaks into smaller networks which continue to work autonomously. Each SyncroAS on the network also provides a RS485 data bus which can accomodate up to 32 field devices such as SyncroVIEW repeaters, SyncroMATRIX mimic displays and ancillary PCB’s. The maximum number of SyncroVIEW or Syncro MATRIX is limited to 15 per RS485 data bus. Networking Features • High integrity protocol • Up to 1,000 mtrs (1Km) between panels • 1 or 2 loops per panel, each loop capable of up to 127 Hochiki devices / 800 sub addressable • Colour graphics interface • Up to 32 field modules per panel on a RS485 data bus • Repeaters & Mimic panels on RS485 data bus • Fully secure against short or open circuit faults • Network wide test and disablement functions • Network wide cause and effect logic 58 QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 WWW.INCITEFIRE.COM.AU SYNCRO AS LARGE SYSTEMS QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 59 WWW.INCITEFIRE.COM.AU SYNCRO REPEATER Syncro View Local LCD Control Panel Repeater Product Overview Designed and manufactured to the highest standards in a quality controlled environment the Syncro VIEW fire alarm annunciator provides a simple and convenient method of extending the controls and indications of the Syncro fire alarm control panel to other locations. The large, graphic liquid crystal display and high brightness LED indicators duplicate the indications on the Syncro fire alarm control panel at up to 15 additional locations via a simple, two-wire serial data connection. The Syncro VIEW is available in either a 24V DC powered option (which can be powered via an additional 2 cores from the Syncro control panel/local 24V DC supply) or a 230V powered option with local battery back up. Syncro View Standard Features Syncro VIEW is housed in a small enclosure which is styled similarly to the Syncro control panel and is ideal for installations where a large control panel would be detrimental to décor such as entrance halls. Up to 15 Syncro VIEW annunciators can be connected to each control panel on the Syncro network making VIEW ideal where multiple points of indication and/or control are required such as nurses stations or shop units. * Up to 15 annunciators can be connected to each Syncro, Response or Syncro AS fire control panel. * Large liquid crystal display (240 x 64 pixels) * High brightness LED indications * Internal sounder * Replicates all Syncro panel controls * Simple, two-wire serial connection * Small, Syncro style enclosure * Removable electronics for easy installation * 24V DC or 230V AC power options * Low power consumption * Multi language options * Connection monitored by Syncro fire control panel 60 QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 SYNCRO REPEATER WWW.INCITEFIRE.COM.AU Technical Specifications Construction 1.2mm mild sheet steel IP RatingIP30 FinishEpoxy powder coated Colour - lid and box BS 00 A 05 grey - fine texture Colour - controls plate & labels Ral 7047 light grey - satin Weight4kg (standard panel) Display 8 lines of 40 characters graphic LCD Cable entry 5 x 20mm knockouts in top of box and 5 in rear Mains supply (Mains models only) 230V AC +10% - 15% (20 Watts maximum) 24V supply (24V DC models only) 21 to 30V DC Mains supply fuse 2 Amp, 20mm Power supply rating 28V 750mA total (including battery charging) Maximum ripple current 200 millivolts Battery type (Yuasa NP) Two 12 Volt 1.9Ah sealed lead acid in series Battery charge voltage 27.6VDC nominal Battery charge current 200mA maximum Battery fuse 200mA, 20mm, glass Maximum current draw from batteries 95mA Quiescent current of panel in mains fail 0.03 Amps Serial data connection 2 core RS485 (Up to 1200 metres total cable length) Maximum terminal capacity 2.5mm² Ordering Syncro View Syncro View repeater panel 255H x 330W x 90D QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 61 WWW.INCITEFIRE.COM.AU SYNCRO LED INDICATION PANEL Syncro Product Overview Programable LED Indication Syncro Ident panels provide a compact and attractive display for up to 24 indications from a Syncro or Syncro AS fire control panel. Panels As with all inputs and outputs on the Syncro system, each indicator is fully programmable to indicate a variety of events as well as being fully programmable via cause and effects to operate in response to logically connected inputs. Each indication defaults to a zonal fire indicator but may be configured via the Loop Explorer configuration utility to operate upon any event type or combination of inputs. Requiring only a low current 24V power supply and a 2 core data connection to the fire panel, Syncro Ident panels can be installed quickly and easily to provide supplementary information on the status of the fire alarm system with the minimum of cost and effort. The compact, slimline enclosure is unobtrusive and is ideal for mounting in locations where a larger control and indication unit would be unsuitable. Syncro Ident Each indication has a dedicated field for customised text to provide a concise description of the indication. Multiple Syncro Ident panels can be connected to the Syncro serial bus to provide a diverse range of indications at multiple locations. Standard Features * 8 and 24 LED versions available as standard * Large versions available to special order * Up to 16 x 24 way Syncro Ident can be connected to each fire panel * Programmable flashing or steady states * Red, yellow or green indications/ options * Common Fire, Fault and Disabled indication * Customisable label identification tags * Buzzer with silence control and re-sound * Lamp test control * Low power 24V DC supply * Connects to 2 wire Syncro RS485 62 QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 SYNCRO LED INDICATION PANEL WWW.INCITEFIRE.COM.AU Technical Specifications Construction 1.2mm mild sheet steel IP RatingIP30 FinishEpoxy powder coated Colour - lid & box BS 00 A 05 grey - fine texture Colour - controls plate & labels RAL 7047 light grey - satin Weight4kg LED colours Red, yellow or green Supply Voltage 18 to 30V DC Data Connection RS485 Syncro comms bus (Max 1200 metres) Indicator Status QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 63 SYNCRO MATRIX WWW.INCITEFIRE.COM.AU Syncro Matrix Intelligent Fire Alarm Mimic Display System Product Overview The Syncro Matrix system uses flexible, fibre optic light guides to illuminate areas on a floor plan, laid over a high resolution grid. This unique system dispenses completely with wiring and enables indicators to be moved, removed or added on site without the need for any wiring. All indicators can be configured to operate upon any event type and at point, zone or group level via Kentec’s powerful and intuitive Loop Explorer configuration programme. Syncro Matrix can be supplied with or without LEDs and controls. Optional LEDs indicate Power on, Fire, Fault and Disablement and optional controls are for Alarm silence, Buzzer silence, Lamp test and Reset. Product Sizes Housed in attractive, slimline enclosures to match Syncro and Syncro AS fire alarm panels and with high quality, full colour or monochrome floor plans, Syncro Matrix provides a clear, geographical indication of fire alarm activation enabling speedy identification of the source of an alarm. Syncro Matrix-CP-M2 Matrix CP Mimic panel in M2 cabinet ( Max 24 zones) Syncro Matrix-CP-M3 Matrix CP Mimic panel in M3 cabinet ( Max 56 zones) Syncro Matrix-CP-S4 Matrix CP Mimic panel in S cabinet ( Max 88 zones) Standard Features * Up to 504 LED’s can be controlled from any Syncro or Syncro AS panel * Full colour printing * Available in a range of standard enclosures to suit any applications * Bespoke sized units can be made upon request * Choice of Red, Green or Yellow LED’s * Available with or without controls * Same look and feel as Syncro range * Syncro Matrix can easily be upgraded on site with minimal cost and effort * Configured via standard Loop Explorer Software 64 QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 WWW.INCITEFIRE.COM.AU SYNCRO MATRIX Technical Specifications Construction IP Rating Finish Colour - lid & box Colour - controls plate & labels Mimic Number of indicators (standard models) Mains supply* Mains supply fuse* 1.2mm mild steel IP30 Epoxy powder coated BS 00 A 05 grey - fine texture RAL 7047 light grey - satin 3mm Clear Anti-Glare Acrylic M2 size - up to 32, M3 and S3 size - up to 64, S4 size - up to 96 230V AC +10% - 15% (100 Watts max.) T2A L250V Replace only with similar type Power supply rating* Maximum ripple current* 5.25 Amps total including battery charge 28V +/ 2V 200 millivolts Battery charge voltage* Battery charge current* Max. current draw from batteries* Supply voltage (24V versions) Terminal capacity Cabinet locks Maximum distance from control panel Operating temperature 27.6VDC nominal (temperature compensated) 1.5A maximum 3 Amps. With mains power source disconnected 18 to 30V DC 0.5mm2 to 2.5mm2 solid or stranded wire M2/M3 - standard 003 key, S3/S4 - standard 003 key 1km with 1.5mm2 cable -5°C to +50°C * When power supply fitted Enclosure Size Options QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 65 WWW.INCITEFIRE.COM.AU SYNCRO NET Syncro Net Syncro Networking Product Overview The flexibility of the Syncro system can be further enhanced by connecting control panels and repeaters together using a high integrity network. A simple 2-wire connection between each panel allows events to be transmitted to other parts of the system to provide indication or control on a system wide basis. Using the Loop Explorer configuration programme, up to 64 nodes can be programmed to respond in a variety of ways to any system events as required. Syncro-K555 This flexibility extends the comprehensive cause and effect programming capability of Syncro control panels to the entire network allowing actions, test modes or disablements to be started from any point. The fault tolerance of the network is such that any single open or short circuit fault will not result in any loss of information. Multiple faults are isolated and the network breaks into smaller networks which continue to work autonomously. With regards to the design of fire systems for larger sites its widely acknowledged globally that instead of producing ever larger loop capacity panels a modular/networked peer-to-peer approach provides a more evenly distributed system. Typically in the past a large system for a 10 storey building may have been designed with a single 10 loop panel. This type of centralised system is far more susceptible to a single critical fault like for instance a display board or maybe a motherboard failure, indeed it could even a structural issue at the location of the FIP. This could leave the whole system incapacitated for a duration of time until a replacement or repair can be made. But the same site suffering the same failures but instead installed with five 2 loop Syncro panels located evenly throughout the 10 floors, would not only incorporate shorter loop cable runs but would in this instance only result in the system either missing 1 of 5 displays or in the worst case scenario have a maximum of two loops non functioning. But the Syncro network would largely remain functional across the rest of the site due to its distributed design. 66 Standard Features * Up to 64 nodes * High integrity protocol * Fully secure against short or open circuit faults * Simple 2-wire loop connection * Supports open ended networks for retrofit applications * Repeaters share network connection * Network wide test and disablement functions * Network wide cause and effect logic * Flexible configuration options * Panels configurable to act on network events or not as required * Hochiki panels supported on single network QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 WWW.INCITEFIRE.COM.AU SYNCRO NET Technical Specifications Product codeSYNCRO-K55 ProtocolRS485 ConnectionTwo wire loop Current Consumption40mA Integrity Full isolation of faulty nodes or wiring segments Indicators Data In and Data Out communications status Cable length 200 metres to adjacent nodes (subject to cable type) (see technical manual) Cable type Belden 9271, Belden 9860, FP200 Gold QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 67 WWW.INCITEFIRE.COM.AU SYNCRO GUIDE Syncro Guide Graphic User Interface for Fire Detection Equipment Product Overview Syncro fire control panels can send data to, and be controlled by, the Guide system providing a single point of co-ordination for all alarms. The powerful 32 bit programme features a standard Windows look and feel and runs under Windows® 2000 , XP, Vista or Windows 7 Professional. The system is highly configurable in terms of the style of presentation so that the end user can be presented with maps, text, photographs, audio or a combination of all as required. User profiles allow the system manager to control the facilities available to each individual system user. A comprehensive history logging and reporting system allows analysis of events and trends to be identified to reduce unwanted alarms. Easy to programme and simple to use, Guide provides a cost effective solution for fire alarm management at many levels. Virtual window allows direct control Standard Features * Choice of text, graphic, event list display when an event occurs * Versatile event analysis * Total history archive * Easy to programme Powerful event log filter * Secure system * Cost effective compared to other systems * Simple to use Unlimited map linking & zoom facility * Support for 100’s of graphics * Display and control for multiple panels * Event history explore and export facility to text or HTML documents 68 QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 SYNCRO GUIDE WWW.INCITEFIRE.COM.AU Technical Specifications Recommended MinimumNotes Processor Intel Pentium 1Ghz The faster the better Operating system Windows® XP/Vista , 7 Will operate under Windows® 2000 Professional Memory1Gb minimumThe larger the better. Hard disk 10GB minimum Graphics 1024 x 768 16M colours The driver must allow this mode with large fonts. Separate Graphics card with 256MB graphics memory recommended Sound card Any PC sound card Loudspeaker Any PC speakers More convenient if built into PC. Monitor Any that supports above 17 inch minimum recommended graphics driver the larger the better. (1024 x 768) Pointing device Mouse essential Third button and wheels are supported. Touch screen option supported PrinterOptionalAny type. Serial ports One RS232 per network Isolated converter supplied for connection to fire alarm system. CDROM drive Any Required for installation of software and updates. Backup drive CD Writer To back up history. Note: Guide will be operating 24 hours a day for many years. It may be desirable to include on site PC maintenance as part of the package. Note: The Syncro panel to which the Guide system is connected must not have a printer fitted. QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 69 WWW.INCITEFIRE.COM.AU SYNCRO COMMS Syncro Comms Communication Module (modem) Product Overview The K556 communications module enables service companies to interrogate control panels remotely via a telephone link. * View devices near calibration limits The communications module is simple to install and requires a PSTN telephone line. * Plan maintenance visits The module mounts on existing pillars in the control panel and is supplied with all wiring and connections to enable speedy installation and commissioning. * Dial in and observe reported faults Once connected to the control panel via the Loop Explorer software, users can upload configuration data and event logs or take control of the system via the virtual panel interface. This allows the panel controls to be operated as if the user was standing at the panel. The Loop Explorer configuration programme (version 3.0 or higher) is used to dial into control panels but the dial up facility will not be available unless the PC calling the control panel is fitted with a registered dongle (part number B2158 for parallel port or B2158USB for USB version). 70 Standard Features * Retrieve event log * Assist commissioning from remote location * Offer value added service to customers * Check software version to see if updates are available * Retrieve configuration * Avoid unnecessary call outs * Simple to install * Dongle protected access, for customers security QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 WWW.INCITEFIRE.COM.AU SYNCRO COMMS Technical Specifications Module part numberSYNCRO-K556 Size190mm(H) x 62mm(W) x 40mm(D) Supply voltage 21V to 30V DC Current consumption50 milliamps ConnectionPSTN Dongle part number B2158 (parallel port) B2158USB (USB serial port) Note: One dongle required per user, to enable the ‘dial in’ facility within the Loop Explorer program Note: The Communications Module is compatible with Loop Explorer Software version 3 or above and Syncro Control Panel Firmware version 3 or above. QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 71