Catalog - Boston Medical Products Inc.
Transcription
Catalog - Boston Medical Products Inc.
NOVATECH PRODUCTS FOR INTERVENTIONAL PULMONOLOGY NOVATECH P RO D UC T S FOR IN TE RVE N TIONAL PULMONOLOGY NOVATECH and Boston Medical Products Bringing you the finest products for Interventional Pulmonology NOVATECH is a manufacturer of top-quality medical products used successfully worldwide in the growing specialty of Interventional Pulmonology. Their original product, the DUMON™ Silicone Stent, has been helping treat patients since 1989, and continues to be the Gold Standard to which all other stents are compared. Boston Medical Products has been manufacturing specialized medical devices for head, neck, and tracheostomy applications since 1980. Boston Medical Products is the proud exclusive U.S. Distributor of NOVATECH products. This catalog features the flagship DUMON™ Silicone Stents, the largest range of models and sizes in the world, along with the TONN™/NOVATECH Stent Applicator System. NOVATECH and Boston Medical Products share a common vision - to develop tailored medical devices to give patients a better quality of life. To this end, we are in constant communication with physicians, nurses, healthcare professionals, and patients themselves, striving to improve our existing products and to develop new products. We are aware of the need for individual solutions, so please contact us if you need special customization of our existing designs. For additional information and to see other exciting products from NOVATECH and Boston Medical Products, please visit www.novatech.fr and www.bosmed.com. Manufactured by: page 2 Exclusive U.S. Distributor: www.bosmed.com www.novatech.fr NOVATECH P RO D UC T S FOR IN TE RVE N TIONAL PULMONOLOGY DUMON™ Tracheal and Bronchial Stents DUMON™ - The Original Silicone Stent The DUMON™ Stent is the original patented design, used successfully worldwide to treat tracheal and bronchial obstructions and stenoses. The stents are made from implant-grade silicone suitable for longterm placement and the only appropriate stent material for benign disease. The stents feature an exclusive surface treatment to ensure nonadherence and to improve mucociliary clearance. The material is flexible enough to allow for atraumatic insertion and placement, yet will seek its original shape following placement, providing the force necessary to correct compressions of the trachea and bronchus. Depending on design, there are two, three or four rows of studs on the outside of the stent. This patented stud design aids in preventing migration by naturally fixing the stent between the cartilaginous rings of the trachea or bronchus while minimizing unnecessary contact between the stent and mucosal surfaces. This design distributes compression forces evenly. It is important to select the appropriate diameter stent to minimize any chance of migration. DUMON™ Stents are available in the following models: Type Rows of Studs Wall Thickness (mm) 4 1.0 4 1.5 4 (Ø ≥ 18 mm: 3) 1.0 BD Straight Bronchial Stent TD Straight Tracheal Stent TF Straight Tracheal Stent BB Pediatric Stent 2 0.5 ST Hourglass Stent 4 1.5 CB Bronchial Stent 4 1.0 Y Y Stent 3 1.0 (Ø ≥ 18 mm: 3) The ends of the stents are straight and specially beveled to maximize airflow while helping to prevent crusting and granulation tissue formation. Animations illustrating the placement of DUMON™ stents are available. Please visit www.bosmed.com Dutau® Forceps REF 6522 Allows the physician to create a smooth fenestration in DUMON™ silicone stents in order to adapt to a specific situation (e.g. ventilation of the upper lobe). www.bosmed.com www.novatech.fr page 3 NOVATECH P RO D UC T S FOR IN TE RVE N TIONAL PULMONOLOGY DUMON™ BD Bronchial Stent – 1.0 mm wall thickness Dimensions below = outside diameter (mm) x length (mm) 02841 9 Product02841 04341 9 Codes04341 / REF: 04371 043719 04391 043919 044119 04411 044219 04421 x9 20 x 20 x9 30 x 30 x9 40 x 40 x9 50 x 50 x 60 x9 60 x 70 x9 70 03721 03841 0372110 10 xx 20 20 0384111 11xx20 20 03741 03861 0374110 10 xx 30 30 0386111 11xx30 30 03761 0376110 10 xx 40 40 03881 0388111 11xx40 40 03781 0378110 10 xx 50 50 03901 0390111 11xx50 50 0380110 10 xx 60 60 0392111 11xx60 60 03801 03921 0382110 10 xx 70 70 03821 03961 12 x 20 03981 12 12 x 30 03961 x 20 04001 12 12 x 40 03981 x 30 04021 04001 12 12 x 50 x 40 04041 04021 12 12 x 60 x 50 04041 x 60 04051 12 12 x 70 04051 12 x 70 Supplied non-sterile. Radiopaque Stents: Add “R” at end of product code (i.e. 02841R = BD 9 x 20 Radiopaque) DUMON™ TD Tracheal Stent – 1.5 mm wall thickness Dimensions below = outside diameter (mm) x length (mm) DUMON™ TD and DUMON™ TF Product03001 03001 11 x 20 20 03021 11 x 30 30 Codes03021 40 / REF: 03041 03041 11 x 40 03061 11 x 50 50 03061 03081 03081 11 x 60 60 03101 03101 11 x 70 70 03121 03121 12 x 20 20 03141 30 03141 12 x 30 03161 40 03161 12 x 40 03181 03181 12 x 50 50 03201 03201 12 x 60 60 03221 03221 12 x 70 70 03231 03231 12 x 80 80 03261 13 x 30 30 03261 03281 03281 03301 03301 03321 03321 03341 03341 03381 03381 03401 03401 03421 03421 03441 03441 03461 03461 03521 03531 03531 03541 03541 03551 03551 03561 03561 03571 13 x 40 40 50 13 x 50 60 13 x 60 70 13 x 70 14 x 30 30 14 x 40 40 14 x 50 50 60 14 x 60 70 14 x 70 15 x 30 20 15 x 40 30 15 x 50 40 15 x 60 50 60 15 x 70 03581 03571 15 x 70 80 03581 15 x 80 03591 90 03591 15 15xx100 90 03491 03491 15 15xx110 100 03501 03621 03501 15 16 x 110 30 03641 03621 16 x 30 40 03661 03641 16 x 40 50 03661 16 x 50 03681 60 03681 16 x 60 03701 70 04281 03701 16 x 70 80 04291 04281 16 x 80 90 04301 04291 16 16xx100 90 04311 04301 16 16xx110 100 04311 16 04131 18 x 110 30 04121 04141 18 18 xx 20 40 04141 04151 18 18 xx 40 50 04151 04161 18 18 xx 50 60 04161 04171 18 18 xx 60 70 04171 04181 18 18 xx 70 80 04181 04191 18 18 xx 80 90 04191 04201 18 18xx100 90 04201 18xx110 100 04211 18 04211 04215 18 20 xx 110 30 04231 04231 20 20 xx 40 40 04241 04241 20 20 xx 50 50 04251 04251 20 20 xx 60 60 04261 04261 20 20 xx 70 70 04271 04271 20 20 xx 80 80 Supplied non-sterile. Radiopaque Stents: Add “R” at end of product code (i.e. 03021R = TD 11 x 30 Radiopaque) DUMON™ TF Tracheal Stent – 1.0 mm wall thickness Dimensions below = outside diameter (mm) x length (mm) DUMON™ TD and DUMON™ TF Product03141F 03141F 12 12 x 30 x 30 03641F 03381F 16 14 x 40 x 30 Codes03161F 03161F 12 12 x 40 x 40 03661F 03401F 16 14 x 50 x 40 / REF: 03261F 03261F 13 13 x 30 x 30 03681F 03421F 16 14 x 60 x 50 03281F 13 13 x 40 16 14 x 70 03281F x 40 03701F 03441F x 60 03301F 03301F 13 13 x 50 x 50 04281F 03461F 16 14 x 80 x 70 03321F 03321F 13 13 x 60 x 60 04291F 16 x 90 03341F 03341F 13 13 x 70 x 70 04301F 16 x 100 03381F 14 x 30 04141F 18 x 40 03401F 14 x 40 04151F 18 x 50 03421F 14 x 50 04161F 18 x 60 03441F 14 x 60 04171F 18 x 70 03461F 14 x 70 04181F 18 x 80 04191F 03641F1816x x9040 04201F 03661F1816x x100 50 04211F 03681F1816x x110 60 04231F 03701F2016x x4070 04241F 04281F2016x x5080 04251F 04291F2016x x6090 04261F 04301F2016x x70100 04271F 20 x 80 04431F 20 x 90 04441F 20 x 100 04451F 20 x 110 04171F 04241F 04261F 04271F 04441F 04451F Supplied non-sterile. Radiopaque Stents: Add “R” to product code (i.e. 03141FR = TF 12 x 30 Radiopaque) page 4 www.bosmed.com www.novatech.fr 18 x 70 20 x 50 20 x 70 20 x 80 20 x 100 20 x 110 NOVATECH P RO D UC T S FOR IN TE RVE N TIONAL PULMONOLOGY DUMON™ BB Pediatric Stent Initially developed for pediatric indications, DUMON™ BB have a wall thickness of only 0.5 mm. The ratio between inner and outer diameter offers an excellent compromise between reduced wall-thickness and resistance to compression. Stent placement is possible with either a rigid scope or, for distal stenoses in adults, with a flexible bronchoscope. Pediatric Indications For pediatric indications, a rigid bronchoscopy must be performed for safety reasons. There is no debate between surgery and stenting as surgery must be the first choice to solve a problem. In some cases stenting can be a good temporary alternative.1) Like all DUMON™ stents, the BB stent is made of implant grade silicone. It is highly biocompatible and removal of the stent is possible any time. DUMON™ BB are available in multiple lengths in order to both cover the stenosis and anchor the stent. The controlled wall thickness aids in avoiding obstruction. In case of necessity, the stent can be removed with foreign body forceps. Adult Indications For adult indications, placement is performed by flexible bronchoscope. Adult indications are rare and must be considered as an exception, when stenting must secure lobar ventilation. Patient quality of life is a key issue when determining the necessity of stenting. Dimensions below = outside diameter (mm) x length (mm) Product025301 5 x 50 Codes / REF: 026201 6 x 50 026501 7 x 50 026701 8 x 50 026751 9 x 80 026501 10 x 80 Supplied non-sterile. Radiopaque Stents: Add “R” at end of product code (i.e. 025301R = 5 x 50 Radiopaque) 1) FAYON, M. et al: French experience of silicone tracheo-bronchial stenting in children. Pediatr Pulmonol. 2005, 39: 21-27 www.bosmed.com www.novatech.fr page 5 NOVATECH P RO D UC T S FOR IN TE RVE N TIONAL PULMONOLOGY DUMON™ ST Hourglass Stent – 1.5 mm wall thickness The DUMON™ ST Stent is an hourglass-shaped stent used successfully worldwide to treat postintubation stenosis and complex tracheal stenoses combining internal & external compressions, as well as postoperative stenosis and cases of tracheal tumor. The silicone material is flexible enough to allow for atraumatic insertion and placement, yet will seek its original shape following placement, providing the force necessary to correct complex compressions of the trachea. The DUMON™ ST series features a wall thickness of 1.5 mm, maximizing airflow and mucociliary clearance, and is available in both clear and radiopaque silicone. Dimensions below = outside diameters (mm) x lengths (mm) of top, middle, and lower portions (i.e. 12-10-12 x 15-20-15 = top portion 12 mm o.d. and length of 15 mm; middle portion 10 mm o.d. and length of 20 mm; lower portion 12 mm o.d. and length of 15 mm) Product Codes / REF: 09041 09031 09051 09011 09061 12-10-12 14-12-14 15-13-15 16-14-16 18-16-18 x x x x x 15-20-15 15-20-15 15-20-15 15-20-15 15-20-15 Supplied non-sterile. Radiopaque Stents: Add “R” at end of product code (i.e. 09041R = 12-10-12 x 15-20-15 Radiopaque) Custom diameters and lengths may be ordered. DUMON™ CB Carina Bronchus Stent - 1.0 mm wall thickness DUMON™ CB Stents feature the original bronchial stent design with an angled flange for compression of main stem bronchi. These stents are specifically designed for the carina, one of the most difficult locations to manage obstructions. They are made from implant-grade silicone suitable for long-term placement and the only appropriate stent material for benign disease. The stent features an exclusive surface treatment to ensure non-adherence. The material is flexible enough to allow for atraumatic insertion and placement yet will seek its original shape following placement, providing the force necessary to correct compressions of the bronchus, and, in particular, the carina. The CB is available in both clear and radiopaque silicone. Dimensions below = outside diameter (mm) x length (mm) Product Codes / REF: 05881 05901 05921 05941 06001 06021 06041 06061 9 x 20 9 x 30 9 x 40 9 x 50 10 x 20 10 x 30 10 x 40 10 x 50 06121 06141 06161 06181 06241 06261 06281 06301 11 11 11 11 12 12 12 12 x x x x x x x x 20 30 40 50 20 30 40 50 Supplied non-sterile. Radiopaque Stents: Add “R” at end of product code (i.e. 05881R = 9 x 20 Radiopaque) page 6 www.bosmed.com www.novatech.fr NOVATECH P RO D UC T S FOR IN TE RVE N TIONAL PULMONOLOGY DUMON™ Y Stent 1.0 mm wall thickness The DUMON™ Y Stent is the original patented design, used successfully worldwide to treat compression of the trachea, carina, and proximal bronchi. Additionally, with a closed right branch, the Y stent can be used to treat pneumonectomized patients with fistulas. The stents are made from implant-grade silicone suitable for long-term placement and the only appropriate stent material for benign disease. The stent features an exclusive surface treatment to ensure nonadherence. The material is flexible enough to allow for atraumatic insertion and placement, yet will seek its original shape following placement, providing the force necessary to correct compressions of the trachea, carina, and proximal bronchi. Dumon Y-Stents have 3 rows of studs. The posterior side has no studs in order to avoid trauma to the tracheo-esophageal wall. The patented stud design aids in preventing migration by naturally fixing the stent between the cartilaginous rings of the trachea while the lower “Y” shape prevents distal migration, minimizing unnecessary contact between the stent and mucosal surfaces. The ends are specially beveled to maximize airflow while helping to prevent crusting and granulation tissue formation. Additionally, custom-made stents with oblique bronchial ends are available. The DUMON™ Y Stents are available in clear silicone. Indications For Use: • Tracheobronchial tumors • Tracheobronchial stenosis with scarring • Tracheobronchial stenosis following resection and anastomosis • Tracheobronchial stenosis following pulmonary transplantation Dimensions below = outside diameters (mm) x lengths (mm) (i.e. 14-10-10 x 110-50-50 = tracheal portion 14 mm o.d. and length of 110 mm; bronchial ends 10 mm o.d. and lengths of 50 mm) outer diameter 1 Product Codes / REF: L1 L2 L3 outer diameter 3 outer diameter 2 091011 09101 092011 09201 093011 09301 094011 09401 09000SC 14-10-10 x 110-50-50 14-10-10 x Custom Lengths (specify) 15-12-12 x 110-50-50 15-12-12 x Custom Lengths (specify) 16-13-13 x 110-50-50 16-13-13 x Custom Lengths (specify) 18-14-14 x 110-50-50 18-14-14 x Custom Lengths (specify) Custom Diameters and Lengths (specify) Custom lengths and diameters may be ordered. Also available on a custom basis is a closed right branch stem for pneumonectomized patients with a fistula. Custom stents with bronchial ends cut at an angle may also be ordered. Please call Customer Service for ordering information. www.bosmed.com www.novatech.fr page 7 NOVATECH P RO DU C T S FOR IN TE RV E N TIONAL PULMONOLOGY TONN™/NOVATECH STENT APPLICATOR SYSTEM basic block pusher clamping rod folding device loading rod introducer tube The new TONN™/NOVATECH Stent Applicator is a complete system for loading and deploying DUMON™ Stents, including “Y” models, through a rigid bronchoscope. Easy to use, the TONN™/NOVATECH Stent Applicator is available in four sizes, allowing the insertion of silicone stents in a wide range of sizes, including large-diameter Y Stents. page 8 Introducer Tube Length (cm) Introducer Tube ID (mm) BLUE 32 12.75 02BRSB120 RED 42 12.75 02BRSR130 GREEN 42 10.25 02BRSG140 WHITE 42 8.2 02BRSW150 REF www.bosmed.com www.novatech.fr NOVATECH P RO D UC T S FOR IN TE RVE N TIONAL PULMONOLOGY TONN™/NOVATECH STENT APPLICATOR SYSTEM Easy Steps for accurate deployment of DUMON™ Stents: Spray lubricant on stent and folding system. Insert introducer into folding system. Position stent and lock in rod. Close folding system. Insert loading rod in opposite end of folding system to load stent into introducer. Remove rod. Stent is now loaded and ready for deployment through rigid bronchoscope. Deployment of stent. TONN™ System Contains one each of the following: Basic Block Folding System Clamping Rod Introducer Loading Rod Pusher Silicone Spray Lubricant Silicone Spray Lubricant Product Code / REF: 68226 www.bosmed.com www.novatech.fr page 9 NOVATECH P RO DU C T S FOR IN TE RV E N TIONAL PULMONOLOGY Which applicator (white, green, red, blue) is used for which stent? TF Length 20 30 40 50 60 70 80 90 100 110 Diameter 12 13 14 15 16 18 PPP PPP PP PP PPP PPP PPP BD P P P P P P P P P P P P P P P P P P P P P P P PPPP PPPP 12 Diameter 11 11 12 P P P P P P P P P P P P PP PP P PPP 6 7 8 9 10 11 12 Y 16 18 P P P P P PPP PPPP PPPP ST P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P 12 P P P P P P P P 14 15 16 18 CB 50/30/30 P P P P P Length 20 30 40 50 60 P P P P Diameter Diameter 15 P P P P P P P P P P Length Length 110/50/50 40/30/30 14 16 PPPP PPPP PPPP PPP PPP PPP 10 20 30 40 50 5 Diameter Diameter 10 P P P P 14 20 20 30 40 50 60 70 80 9 13 18 BB Length Length 30 40 50 60 70 80 90 100 110 Diameter TD 9 10 11 12 P P P P P P P P P P P P P P P PP NB : Stents which can be placed with the BLUE system can also be placed with the RED system. For stents not appearing in the chart and/or for custom made stents, please contact our customer service. page 10 www.bosmed.com www.novatech.fr www.bosmed.com www.novatech.fr page 11 Manufactured by: Exclusive U.S. Distributor: To Place an Order Warranty Our Customer Service Representatives are available from 8:30 a.m. to 5:00 p.m. (EST) Monday through Friday. Orders can also be placed through our 24-hour fax line. • Customer Service: 800-433-2674 (toll-free in the U.S. and Canada) • Main Telephone: 508-898-9300 • 24-hour-Fax: 508-898-2373 Boston Medical Products, Inc. warrants that reasonable care has been used in the manufacturing of all products. All products are warranted to be free of defects at the time of shipment. For specific product warranties, please refer to individual product instructions for use. Shipment MK-NOVA-13A — 2013-10 • Standard shipping within the U.S. is FedEx two-day delivery. • Express orders are accepted until 3:00 p.m. (EST) for next business day delivery nationwide. • Most orders are shipped the same day. • Saturday delivery is available in many areas. Return Policy Boston Medical Products, Inc. will accept returned items that are unopened in the original packaging. • Please call Customer Service to obtain a Return Authorization. • Returns accepted within 30 days from invoice date. • A Return Authorization is required for all returns. • All returns are subject to a restocking fee. • Merchandise credit only. Exclusive U.S. Distributor: Boston Medical Products, Inc. 117 Flanders Road, Westborough, MA 01581 USA T: 508.898.9300 • F: 508.898.2373 www.bosmed.com • info@bosmed.com