Series 92 Electronic Gas Modulation System DESCRIPTION SYSTEM COMPONENTS The Selectra Series 92 system is used to obtain higher turndown on indirect fired applications. SERIES 92 Amplifier Selectra systems maintain stable, precise temperatures. A significant improvement over mod motors and butterfly valves - M/MR valves provide instantaneous response and continual pressure adjustment. A1092 Modulator Valves The TD92-0509 remote temperature dial controls a 50° to 90°F range. It is similar in design to our popular TD94, but with no digital readout. It has a 6-place terminal block for lead connections. The A1092/A1192 amplifier functions similarly to an A1094, but uses standard wires (4) to connect to the TD92 instead of ribbon cable. Maximum recommended wire length is 300ft. Pipe Sizes: M420........................3/8” & 1/2” M520........................1/2” & 3/4” M620.........................3/4” & 1” Duct temperature sensing is by 1,000 ohm RTD such as TS3943B-48FQ or TS194Q (w/mixing tube). Remote Temperature Selector An optional T115 room override thermostat, when used in conjunction with the remote temperature selector, provides space temperature control by raising the discharge air temperature to a pre-selected point. TD92-0509 - (50° to 90°F) Upon request, Maxitrol can configure Series 92 components for other desired temperature control ranges. Discharge Temperature Sensors: use with Mixing Tube SPECIFICATIONS TS194Q Pressure Limits for M420, M520, M620 Maximum Discharge Pressure............................7” w.c. (1.7 kPa) Maximum Operating Inlet Pressure......................1.0 psi (7 kPa) Maximum Emergency Exposure*...........................3.0 psi (21 kPa) *May not function properly at this pressure, but will suffer no internal damage. Mixing Tubes: use with Sensor Lengths: MT1-9 or 2-9........................9” MT1-12 or 2-12 ................. 12” MT1-23 or 2-23 ................ 23” MT1-28 or 2-28 ................. 28” MT1-57.............................. 57” Power Supply A1092: Independent 24 VAC, 40VA, 50/60 Hz Class II transformer A1192 Independent 24 VAC, 100VA, 50/60 Hz Class II transformer NOTE: Transformer must have sufficient rating to cover amperage load. Temperature Sensor Gases Suitable for natural, manufactured, mixed gases, liquified petroleum gases, and LP gas-air mixtures. TS394-3B-48FQ Vent M420, M520, M620: Vertical vent outlet 1/8” NPT - 12A06 installed NOTICE OPTIONAL: Room Override Thermostat Maxitrol vent limiting devices eliminate the need to run vent piping to the outside. Vent limiting devices are designed for use indoors and in spaces where limiting the amount of gas escapement due to diaphragm failure is critical. Vent limiting devices should not be used outdoors if they are exposed to the environment. Vent protector 13A15 is available for all outdoor applications to ensure proper vent protection. © 2012 Maxitrol Company, All Rights Reserved. T115 1 Series 92 Electronic Gas Modulation System SPECIFICATIONS (cont.) Ambient Limits Operating: Non Operating: VALVE ADJUSTMENT See Bulletin MMR_MT_EN for additional M/MR valve information 32° to 131°F (0° to 55°C) -4° to 158°F (-20° to 70°C) NOTE: Low Fire Adjustment should be checked whenever High Fire Adjustment is changed. Modifications Models M420, M520, M620 are available as “W” models indicates covered wire terminal connections. High Fire Adjustments Rotate selector dial to maximum temperature setting. Models M420, M520, M620 are available with side pressure tap for reading outlet pressure - on side opposite of minimum adjustment mechanism. NOTE: Voltage to the valve must be at least 18VDC. Valve Mounting Valve must be mounted in upright position in horizontal pipe run, downstream of all other controls except high pressure cut-off switch if used. Low Fire Adjustments Disconnect a wire from M valve terminal block. Adjust separate pressure regulator to obtain desired manifold pressure. NOTE: Be careful not to allow wire to come in contact with any other part. Remove by-pass cap (A) and turn screw (B) using small screwdriver to desired low fire adjustment. (See Figure 1) Optional T115 Room Override Thermostat As an optional component, an independent room override adjustment can be provided to permit setting of the override temperature from 0° to 40°F above the TD92 setpoint. The T115 override thermostat senses room temperature and resets the discharge air to a higher temperature whenever the sensed temperature falls below the T115 setting. NOTE: Clockwise Screw rotation reduces flow rate. Do not overtighten. The standard configuration is to connect the T115 override thermostat to the TD92 remote temperature dial. In some cases it may be more convenient to connect the T115 to the A1092 amplifier. The T115 may be connected directly by removing the jumper on the amplifier’s input terminal block and connecting the T115 in its place. The jumper must then be installed across the TD92’s override terminals for proper operation. See Wiring Diagrams (Figures 2 - 8). B A © 2012 Maxitrol Figure 1: Valve Adjustment WIRING DIAGRAMS JUMPER NOT REQUIRED ACROSS TERMINALS 11 & 12 Figure 2: Standard Connection of A1092 without Override Thermostat © 2012 Maxitrol Company, All Rights Reserved. 2 © 2012 Maxitrol Series 92 Electronic Gas Modulation System WIRING DIAGRAMS (cont.) JUMPER REQUIRED ACROSS TERMINALS 11 & 12 © 2012 Maxitrol Figure 3: Standard Connection of Override Thermostat to A1092 JUMPER REQUIRED ACROSS TERMINALS 5 & 6 © 2012 Maxitrol Figure 4: Optional Connection of Override Thermostat to A1092 © 2012 Maxitrol © 2012 Maxitrol Figure 5: A1192 Independent Power Supply Figure 7: A1092 Independent Power Supply © 2012 Maxitrol © 2012 Maxitrol Figure 6: A1192 Common Power Supply © 2012 Maxitrol Company, All Rights Reserved. Figure 8: A1092 Common Power Supply 3 Series 92 Electronic Gas Modulation System DIMENSIONS 1.69 1.69 (59.8) (43) TYP. TYP. 1.41 1.41 (49.9) (36) TYP. TYP. in. (mm) in. (mm) 2.96 2.96 (75) (105) TYP. TYP. 80 90 4.00 SQ. (102) 70 °F 60 40 4.68 4.68 (165.7) (119) TYP. TYP. 50 3.46(122.5) (88) 3.46 3.25 3.25(115.1) (83) R 50 60 70 80 90 2.56 2.56 (90.6) (65) TYP. TYP. © 2012 Maxitrol Figure 9: TD92-0509 © 2012 Maxitrol Figure 10: Optional T115 Room Override Thermostat in. (mm) TYP. 1.89 TYP. 2.25 (57) (57.2) (48.0) (48) 3.00 (76) (76.2) 8 5 6 7 4 9 R 3 10 2 A1092 11 1 12 3.38 3.38 (86) (85.9) CENT. CENT. 7.50 (191) (190.5) 9.50 (241) 2.71 2.71 (69) (68.9) TYP. 1.75TYP. 1.75 2.75 2.75 (44.5) (45) (69.9) (70) CENT. CENT. 5.55 (141) CENT. CENT. R A1192 2.75 2.75 (70) (69.9) TYP. TYP. 1.25 1.25 (32) (31.8) TYP. TYP. 8.00 8.00 (203) (203.2) TYP. TYP. .75 .75 (20) (19.1) TYP. TYP. © 2012 Maxitrol Figure 11: A1092 Valve Dimensions Dimensions Model Number Swing Radius A B C D M420 3.1” (79 mm) 3.9” (100 mm) 2.0” (51 mm) 2.1” (54 mm) 0.9” (24 mm) M520 4.3” (109 mm) 5.3” (135 mm) 3.25” (83 mm) 3.4” (86 mm) 1.2” (30 mm) M620 5.7” (146 mm) 7.1” (180 mm) 3.9” (99 mm) 4.0” (102 mm) 1.5” (37 mm) NOTE: Dimensions are to be used only as an aid in designing clearance for the valves. Actual production dimensions may vary somewhat from those shown. Maxitrol Company 23555 Telegraph Rd., P.O. Box 2230 Southfield, MI 48037-2230 U.S.A. SEL92_MS_EN_07.2012 4 A B D C © 2012 Maxitrol Figure 12: M420, M520, AND 620 Modulating Valves www.maxitrol.com © 2012 Maxitrol Company, All Rights Reserved.
Similar documents
DESCRIPTION M/MR Modulating Valves TABLE OF
Whether your needs are problem-free stabilized area heating, elevated heating, consistent higher baking/drying temperatures or other process applications, maintaining consistent temperatures is no ...
More information