Variable Speed Multi-Stage Vertical Pumps (max 2900
Transcription
Variable Speed Multi-Stage Vertical Pumps (max 2900
07/2014 MXV-E Variable Speed Multi-Stage Vertical Pumps (max 2900 rpm) Construction Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line). Corrosion-resistant bearing sleeves lubricated by the pumped liquid. MXV-E (AISI 304) Internal parts in contact with the liquid in chrome-nickel stainless steel 304, with pump casing and upper cover in cast iron for MXV-E 50-65-80. MXVL-E (AISI 316L) Internal parts in contact with the liquid in Cr-Ni-Mo AISI 316L, including pump casing and upper cover for MXVL-E 50-65-80. 12 Applications Building services pressure boosting. Water supply to multi-storey buildings. Washing plants. Industrial pressure boosting systems. Performance curve adjustment for industrial system application. Operating conditions For clean non-explosive liquids, without solid, filamentary or abrasive matter (with adaptation of sealing materials on request). Temperature of liquid: from -15 °C to +110 °C. Operating environment temperature: up to 0 ÷ 40 °C. Maximum permissible pressure in pump casing: 25 bar. Materials (wetted parts) For all types 50,65,80 25,32,40 Inverter-Motor Component MXV-E ( AISI 304) MXVL-E (AISI 316L) Flange External jacket Suction casing Delivery casing Stage casing Impeller Lower cover Upper cover Spacer sleeve Cr-Ni steel 1.4301 EN 10088 (AISI 304) Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L) Special features on request Cast iron GJL 250 EN 1561 Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L) External jacket Stage casing Impeller Spacer sleeve Cr-Ni steel 1.4301 EN 10088 (AISI 304) Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L) Pump shaft Plug Cr-Ni steel 1.4305 EN 10088 (AISI 303) Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L) Pump casing Upper cover Bearing sleeve/ Bearing in stage casing Mechanical seal ISO 3069 - KU Rated speed of rotation (50/60 Hz): max n = 2900 rpm Inverter supply: three-phase 380-480 V ± 5%, 50/60 Hz. 2-pole induction motor. Construction IM B5. Insulation class F. Protection IP 55. Corrosion-resistant, cemented carbide/ Ceramic alumina PTFE O-rings NBR Designation MXV L - E 25 -2 05 G MXV L - E 50-16 05 H1 Series AISI 316L Version (no code = AISI 304 version) Variable Speed DN ports in mm Rated capacity in m3/h (n = 2900 rpm) Number of stages Hard metal/Carbon/EPDM Wear ring - Special mechanical seal. - O-rings FPM. - Higher or lower liquid or ambient temperatures. - Flanges to screw, in chrome-nickel steel for MXV-E 25-32-40. Construction variants threaded ports flanged ports with support feet for horizontal installation H, variant 1 113 G F MXV-E Variable Speed Multi-Stage Vertical Pumps Advantages - Energy saving. - Compact Design. - Economical use of space. - Flexible operation. - Low-noise operation. - Programmable to suit the system requirements. Main features Control range 1500 to 2900 rpm. Dry-running protection. Phase failure protection. Overload protection. Low-noise: max 64 dB(A). Modality of use 200 200 Constant pressure mode With a pressure transducer the system maintains a constant pressure with variation of flow. 150 H 100 m Fixed speed mode max 150 Variation of the operating frequency allows for the choice of operating curve to match the system requirements H 100 m 50 50 0 0 min 0 2 4 6 Q m 3/h 8 0 2 4 6 Q m 3/h 8 The system is factory programmed and can be easily modified via the local control panel (optional). Coverage chart n ≈ 2900 rpm 4 5 Imp. g.p.m. 10 20 30 40 50 100 200 250 800 MXV-E n ≈ 2900 1/min 700 200 H H ft m 500 150 25-2 40-8 32-4 400 100 300 50-16 200 50 65-32 100 80-48 0 1 Q m3/h l/min 2 30 3 40 50 4 5 6 100 7 8 9 10 150 16 200 20 300 32 400 500 40 48 60 70 1000 72.936/1 114 0 MXV-E Variable Speed Multi-Stage Vertical Pumps Characteristic curves and performance n ≈ 2900 rpm 0 U.S. g.p.m. 5 10 15 20 240 MXV-E 25-220 220 n ≈ 2900 1/min 700 200 18 600 180 16 ft H m 14 500 12 140 12 400 120 10 100 300 8 80 7 6 60 200 5 4 40 100 20 0 0 0 Q m3/h l/min 1 2 20 30 40 3 50 5 4 60 70 0 80 0.2 50 η Pst Pst 40 0.1 η % kW 30 4 0 10 NPSH Test results with clean cold water, without gas content. A safety margin of + 0.5 m is recommended for the NPSH value. Tolerances in accordance with UNI EN ISO 9906:2012. ft 2 Head and power values valid for liquids with density ρ = 1,0 kg/dm3 and kinematic viscosity ν = max 20 mm2/sec. m 0 0 Q m3/h 1 2 3 72.983 4 0 5 Pst = Power with reference to one stage. Q MXV-E 25 - 204 MXV-E 25 - 205 MXV-E 25 - 206 MXV-E 25 - 207 MXV-E 25 - 208 MXV-E 25 - 210 MXV-E 25 - 212 MXV-E 25 - 214 MXV-E 25 - 216 MXV-E 25 - 218 MXV-E 25 - 220 m3/h P2 Pump type kW HP 0,75 1,1 1,1 1,5 1,5 2,2 2,2 3 3 3 4 1 1,5 1,5 2 2 3 3 4 4 4 5,5 l/min H m 0 1 1,5 2 0 16,6 25 33,3 44 56 68 79,5 91 114 136 159 182 205 228 42,5 53 63,5 74 85 106 127 149 170 191 213 40 50 60,5 70,5 80,5 101 121 141 161 181 202 37,5 47 56 65,5 75 94 112 131 150 169 188 115 3 3,5 41,6 50 58,3 66,6 75 34,5 43 51,5 60 69 86 103 121 138 155 173 31 39 46,5 54,5 62 78 93,5 109 124 140 156 27 34 40,5 47,5 54 68 81,5 95 108 122 136 22,5 28 34 39,5 45,5 57 68 79,5 91 102 114 17 21 25 30 34 42 51 59 68 76 85 2,5 4 4,5 MXV-E Variable Speed Multi-Stage Vertical Pumps Characteristic curves and performance n ≈ 2900 rpm 0 U.S. g.p.m. 10 20 30 240 n ≈ 2900 1/min 220 700 200 MXV-E 32-418 600 180 H ft 16 m 500 14 140 12 120 400 10 100 300 8 7 6 5 4 80 60 40 200 100 20 0 0 0 3 m /h Q l/min 2 3 50 55 4 5 6 100 7 9 150 8 0.25 η η 0 0.2 Pst Pst kW 45 % Test results with clean cold water, without gas content. A safety margin of + 0.5 m is recommended for the NPSH value. Tolerances in accordance with UNI EN ISO 9906:2012. 0.1 0.05 35 4 10 NPSH ft 2 Head and power values valid for liquids with density ρ = 1,0 kg/dm3 and kinematic viscosity ν = max 20 mm2/sec. m 0 0 Q m3/h 2 3 4 5 6 7 72.984 8 0 Pst = Power with reference to one stage. 9 Q MXV-E 32 - 404 MXV-E 32 - 405 MXV-E 32 - 406 MXV-E 32 - 407 MXV-E 32 - 408 MXV-E 32 - 410 MXV-E 32 - 412 MXV-E 32 - 414 MXV-E 32 - 416 MXV-E 32 - 418 m3/h P2 Pump type kW HP 1,1 1,5 1,5 2,2 2,2 3 3 4 4 5,5 1,5 2 2 3 3 4 4 5,5 5,5 7,5 l/min H m 0 2,5 3 3,5 0 41,6 50 58,3 45 56 68 79,5 91 114 136 159 182 205 41,5 51,5 62 72,5 83 104 124 145 166 187 40 50 60 70,5 80,5 101 121 141 161 181 38,5 48 58 68 78 97,5 117 136 156 175 116 6 7 8 83,3 100 116,6 133,3 32,5 41 49,5 58 66 83 99,5 116 132 149 27,5 34,5 42 49 56 70 84 98 112 126 22 27,5 33,5 39 44,5 56 67 78 89,5 100 14,5 18,5 22,5 26,5 30 38 45,5 53 60,5 68 4,5 5 66,6 75 36,5 46 55,5 65 74 93 111 130 148 167 34,5 43,5 52,5 61,5 70 88 105 123 140 158 4 MXV-E Variable Speed Multi-Stage Vertical Pumps Characteristic curves and performance n ≈ 2900 rpm U.S. g.p.m. 0 20 30 40 50 60 240 n ≈ 2900 1/min 220 200 700 MXV-E 40-817 600 180 H ft 15 m 500 13 140 12 400 120 10 100 300 8 80 7 60 5 200 4 40 100 20 0 0 0 Q m3/h 2 l/min 4 6 100 50 8 10 14 12 200 150 70 0 0.4 η Pst η Pst 60 0.2 % Test results with clean cold water, without gas content. A safety margin of + 0.5 m is recommended for the NPSH value. Tolerances in accordance with UNI EN ISO 9906:2012. kW 50 4 0 NPSH 10 ft 2 Head and power values valid for liquids with density ρ = 1,0 kg/dm3 and kinematic viscosity ν = max 20 mm2/sec. m 0 0 0 Q m3/h 2 4 6 8 10 72.392 12 Pst = Power with reference to one stage. 14 Q MXV-E 40 - 804 MXV-E 40 - 805 MXV-E 40 - 807 MXV-E 40 - 808 MXV-E 40 - 810 MXV-E 40 - 813 MXV-E 40 - 815 MXV-E 40 - 817 m3/h P2 Pump type kW HP 2,2 2,2 3 4 5,5 5,5 7,5 7,5 3 3 4 5,5 7,5 7,5 10 10 l/min H m 0 5 6 7 8 9 10 11 12 13 0 83,3 100 116,6 133,3 150 166,6 183,3 200 216,6 47 59 83 95 119 155 179 202 43 54 76 87 109 141 163 184 42 53 74 85 106 138 159 180 41 51 72 82 103 134 154 175 40 50 69 79 99 129 149 168 37 47 66 75 94 122 141 159 34 43 60 69 86 111 128 145 30 38 53 60 75 98 113 128 26 32 45 51 64 84 96 109 21 26 36 42 52 68 78 89 117 MXV-E Variable Speed Multi-Stage Vertical Pumps Characteristic curves and performance n ≈ 2900 rpm 0 U.S. g.p.m. 20 40 60 80 100 n ≈ 2900 1/min 140 400 MXV-E 50-1607 120 ft 6 100 H 300 m 5 80 4 200 60 3 40 100 20 0 0 0 Q m3/h l/min 5 10 100 150 15 200 20 250 300 25 350 0 400 1.0 80 Pst η Pst η 60 0.6 % kW 40 8 0.2 Test results with clean cold water, without gas content. A safety margin of + 0.5 m is recommended for the NPSH value. Tolerances in accordance with UNI EN ISO 9906:2012. 20 NPSH ft 4 Head and power values valid for liquids with density ρ = 1,0 kg/dm3 and kinematic viscosity ν = max 20 mm2/sec. 10 m 0 0 Q m3/h 5 10 72.937 20 Pst = Power with reference to one stage. 25 Q P2 Pump type MXV-E 50 - 1603 MXV-E 50 - 1604 MXV-E 50 - 1605 MXV-E 50 - 1606 MXV-E 50 - 1607 15 m3/h kW HP 4 5,5 5,5 7,5 7,5 5,5 7,5 7,5 10 10 l/min H m 0 8 10 12 14 16 18 20 22 24 0 133,3 166,6 200 233 266 300 333 366 400 51 69 86 103 120 49 65 81 98 114 48 63 79 95 111 46 61 76 92 107 44 59 73 88 103 41 55 69 83 97 38 51 63 76 89 33 44 55 67 78 27 37 46 55 64 20 27 33 40 47 118 MXV-E Variable Speed Multi-Stage Vertical Pumps Characteristic curves and performance n ≈ 2900 rpm 0 50 U.S. g.p.m. 100 200 150 100 300 n ≈ 2900 1/min 80 ft H m 12 200 60 MXV-E 65-3203 40 2 100 20 0 0 0 Q m3/h l/min 10 20 200 300 30 500 400 50 40 600 700 0 800 80 2 Pst η Pst η 60 1 % Test results with clean cold water, without gas content. A safety margin of + 0.5 m is recommended for the NPSH value. Tolerances in accordance with UNI EN ISO 9906:2012. kW 40 8 0 NPSH 20 ft 4 m 0 0 Q 3 m /h 10 20 72.938 40 Head and power values valid for liquids with density ρ = 1,0 kg/dm3 and kinematic viscosity ν = max 20 mm2/sec. 0 Pst = Power with reference to one stage. 50 Q P2 Pump type MXV-E 65 - 3202 MXV-E 65 - 3203 30 10 m 3/h 0 15 21 24 27 30 33 36 39 44 kW HP l/min 0 250 350 400 450 500 550 600 650 733 4 7,5 5,5 10 H 37 55,5 34 51 32 49 31 47,5 30 46 29 43,5 27 40,5 24,5 37 22 33,5 17 25,5 m 119 MXV-E Variable Speed Multi-Stage Vertical Pumps Characteristic curves and performance n ≈ 2900 rpm 0 U.S. g.p.m. 50 200 150 100 250 100 300 n ≈ 2900 1/min 80 ft H m 200 60 MXV-E 80-4803 40 2 100 1 20 0 0 0 Q m3/h 10 l/min 200 20 300 30 400 40 500 600 700 800 0 60 50 900 1000 80 70 4 Pst 3 kW 2 η η% 60 Pst 50 40 Test results with clean cold water, without gas content. A safety margin of + 0.5 m is recommended for the NPSH value. Tolerances in accordance with UNI EN ISO 9906:2012. 1 ft 6 NPSH ft 4 m Head and power values valid for liquids with density ρ = 1,0 kg/dm3 and kinematic viscosity ν = max 20 mm2/sec. 10 2 0 Pst = Power with reference to one stage. 0 0 Q m3/h 10 20 MXV-E 80 - 4801 MXV-E 80 - 4802 MXV-E 80 - 4803 50 72.1035 60 Q P2 Pump type 40 30 kW HP 3 5,5 7,5 4 7,5 10 m3/h 0 21 27 33 39 45 48 51 54 60 l/min 0 350 450 550 650 750 800 850 900 1000 20 40,5 61 18 36 54 17 34,5 51 16 32,5 48 15 29,5 44 13 26,5 40 12 24,5 37 10,7 22 34 9,5 20 31 7 15,5 24,5 H m 120 MXV-E Variable Speed Multi-Stage Vertical Pumps Dimensions and weights AD Pompa Pump Pump (3) fM (1) (2) DN DN h1 3.93.011/1 a af n2 n1 s m2 m1 MXV-E (G) bocche filettate threaded threaded ports ports Motore Motor kW HP MXV-E 25-204 MXV-E 25-205 MXV-E 25-206 MXV-E 25-207 MXV-E 25-208 MXV-E 25-210 MXV-E 25-212 MXV-E 25-214 MXV-E 25-216 MXV-E 25-218 MXV-E 25-220 0,75 1,1 1,1 1,5 1,5 2,2 2,2 3 3 3 4 1 1,5 1,5 2 2 3 3 4 4 4 5,5 MXV-E 32-404 MXV-E 32-405 MXV-E 32-406 MXV-E 32-407 MXV-E 32-408 MXV-E 32-410 MXV-E 32-412 MXV-E 32-414 MXV-E 32-416 MXV-E 32-418 MXV-E 40-804 MXV-E 40-805 MXV-E 40-807 MXV-E 40-808 MXV-E 40-810 MXV-E 40-813 MXV-E 40-815 MXV-E 40-817 1,1 1,5 1,5 2,2 2,2 3 3 4 4 5,5 1,5 2 2 3 3 4 4 5,5 5,5 7,5 2,2 2,2 3 4 5,5 5,5 7,5 7,5 3 3 4 5,5 7,5 7,5 10 10 G a ISO 228 215 G1 215 G11 / 4 G11 / 2 225 MXV-E (F) bocche flangiate flanged flanged ports ports DN af 250 25 250 32 40 280 Peso netto Net mm Net weight weight h1 fM AD 75 627 675 699 723 747 812 860 908 956 1004 1052 149 153 153 153 153 169 169 169 169 169 184 75 651 675 699 740 764 812 860 908 1000 1133 153 153 153 169 169 169 169 186 186 212 80 697 727 787 861 1026 1116 1176 1236 169 169 169 186 186 212 212 212 n1 n2 210 180 210 180 246 215 m1 150 150 190 m2 100 100 130 s kg 12,5 31 38 39 43 44 53 54 56 57 59 69 12,5 38 39 42 50 51 54 55 66 67 87 14 48 49 53 64 89 91 98 99 (3) Posizione standard scatola morsetti (altre posizioni ruotando motore di 90° 180°) (2) Scarico(3) Standard (1) Riempimento Filling (2) Draining position of terminal box. (for other positions rotate motoril through 90° oro180°) Standard position of terminal box. (for other positions rotate motor through 90° or 180°) Draining Filling AD mm Pompa Pump Pump (4) G 3/8 (1) fM G 3/8 (3) G 1/8 (2) DN Net weight weight kW HP MXV-E 50-1603 MXV-E 50-1604 MXV-E 50-1605 MXV-E 50-1606 MXV-E 50-1607 4 5,5 5,5 7,5 7,5 5,5 7,5 7,5 10 10 MXV-E 65-3202 MXV-E 65-3203 MXV-E 80-4801 MXV-E 80-4802 MXV-E 80-4803 4 7,5 3 5,5 7,5 5,5 10 4 7,5 10 a DN 65-80 Flange FlangesFlanges EN 1092-2 PN 25 - 40 260 DN 50 220 h1 fm AD kg 730 824 858 893 927 186 212 212 212 212 79 80 105 112 113 741 847 745 840 901 186 212 186 212 212 82 113 73 107 115 50 300 90 65 320 105 80 320 105 Standard position of terminal box. (for other positions rotate motor through 90° or 180°) 4.93.210/2 260 a (4) Posizione standard scatola morsetti (altre posizioni ruotando il motore di 90° o 180°) h1 220 DN (1) Filling and air vent (2) Sfiato aspirazione (3) Draining (1) e sfiato (3) Scarico (2)box. Sfiato (4) Riempimento Standard position of terminal (foraspirazione other positions rotate motor through 90° or 180°) Filling and air vent Draining Air vent suction side DN 14 Peso netto Net Motor Motore Motor Fori - Holes Holes DN DG DK DE DN DG DK DE DN DE DK DG N. Ø 50 65 165 185 125 145 99 118 4 8 19 19 80 200 160 132 8 19 121 12 MXV-E Variable Speed Multi-Stage Vertical Pumps Features MXV-E pump series with on-board Danfoss® frequency controller. The MXV-E series is available with motors up to 7.5 kW, connected directly to the MXV series of vertical, in-line multi-stage pumps (see the Calpeda general catalogue for more information). For units over 7.5 kW we offer panel mounted control systems. Motor with factory programmed integrated frequency controller, series VLT FCM 300. Programmable Local Control Panel with alphanumerical display. Service plug with cable kit for a simple connection to the Local Control Panel. The frequency converters feature a RS 485 connection. Provision to connect a potentiometer to regulate the set point. 122