Installation Instructions

Transcription

Installation Instructions
D42521-002 © 04-2010
Carrier Frame for Wall-hung Urinal
Geberit Model No.: 111.625.00.1
965.330.00.0 (00)
Product Data
3"
193/4"
43/4-121/2" NPT
min. 31/2"
393/8-461/2"
NPT
1/2"
55/8141/2"
1/2"
NPT
1/2"
3-13"
31/2"
FRH
max.
255/8"
44-51"
2" (50)
FF
17/8"
27/8"
3/8-31/2"
Product Specifications
- For installing 2-hole stud mounted urinals with rear water
inlet. NOTE: Not for hanger mounted urinals or
spud mounted flushometer valves
- For HyTouch urinal controls with plate
size 5.1 x 5.1" (130 x 130)
- Fits within minimum 3" (75) plumbing wall
- 1/2" water supply
Warranty
Limited lifetime warranty on carrier.
Standards
In compliance with
- ASME A112.6.2
- ASSE 1037
- CSA B125.3
2
min. 351/2"
Material Determination
Recommended material for wall surface construction:
- Gypsum / green board
- Cement board
- Tile backer board
- Ceramic tile surface
Wall thickness not to exceed 31/2".
D42521-002 © 04-2010
Features
- Square structural 16 gauge powder coated steel frame
- Stop valve with throttle pre-mounted
- Vacuum breaker
- Fully height-adjustable frame, flush valve rough-in, water
inlet, mounting studs and waste outlet
- Fastening for outlet bend sound-absorbing
- Mounting hardware
Installation
Installation Requirements
To install carrier, a minimum 3" (75) wall is required.
A 2 x 6" wood frame or metal frame construction is
recommended. Studs must be placed 19 3/4" apart
(clearance) where carrier will be positioned inside the wall.
FV
UT
W
Prepare
These values are needed to set proper values at roughing in:
FF: Finished Floor Height
FRH: Finished Rim Height
UT: Urinal Top Height, based on ceramic model and FRH
FV: Flush Valve Height, subject to conditions below
R
FRH
D
FV_min: minimum Flush Valve Height = UT + 3 1/2" (90)
H_min: minimum Frame Height
= UT + 8 1/4" (210) or
44 1/8 (1200),
whichever is greater.
H_max: maximum Frame Height
= 51 3/16" (1300)
For convenience, values are calculated in the included chart.
Ceramic manufacturer specifications are subject to
change without notice.
Always refer to the ceramic manufacturer
specification sheet for the latest information!
Geberit is not responsible for inaccuracies or
changes in the information contained in the chart.
Manufacturer
D42521-002 © 04-2010
Duravit
Villeroy & Boch
Collection
Base
Model
Caro (with lid)
083630
Starck 1
083432
Starck 1 (with lid)
083532
Vero (no lid)
280032
Vero (with lid)
281032
Aveo
7514
Hommage
7553
Century
7553
Oblic
7531
Pure Stone
7514
Subway
7513
Finished
Rim
Height
(FRH)
17
24
17
24
17
24
17
24
17
24
17
24
17
24
17
24
17
24
17
24
17
24
Urinal
Top
(UT)
FV_min
27 1/16
34 1/16
23 5/16
30 5/16
23 5/16
30 5/16
24 1/2
31 1/2
24 1/2
31 1/2
25 7/8
32 7/8
25 11/16
32 11/16
25 11/16
32 11/16
25 11/16
32 11/16
25 7/8
32 7/8
26 7/16
33 7/16
30 9/16
37 9/16
26 13/16
33 13/16
26 13/16
33 13/16
28
35
28
35
29 3/8
36 3/8
29 3/16
36 3/16
29 3/16
36 3/16
29 3/16
36 3/16
29 3/8
36 3/8
30
37
H
193/4"
FF
0 - 7.85"
These dimensions are used later, after frame is installed:
R: Rod Height, based on ceramic model and FRH
W: Water Inlet Height, based on ceramic model and FRH
D: Drain Outlet Height, based on ceramic model and FRH
RC: Rod Center-to-Center Distance, based on ceramic model
H_min
44 1/8
FV_max
46 7/16
H_max
Rods (R )
Water
Inlet
(W)
Drain
Outlet
(D)
51 3/16
25 11/16
32 11/16
13 5/8
20 5/8
13 5/8
20 5/8
13 5/8
20 5/8
13 5/8
20 5/8
16
23
19 3/4
26 3/4
19 3/4
26 3/4
14 7/16
21 7/16
16
23
18 3/16
25 3/16
23 5/16
30 5/16
19 15/16
26 15/16
19 15/16
26 15/16
22 11/16
29 11/16
22 11/16
29 11/16
22 5/16
29 5/16
22 7/8
29 7/8
22 7/8
29 7/8
22 1/8
29 1/8
22 5/16
29 5/16
23 7/8
30 7/8
7 3/8
14 3/8
6 3/8
13 3/8
6 3/8
13 3/8
6 3/4
13 3/4
6 3/4
13 3/4
5 3/4
12 3/4
6 9/16
13 9/16
6 9/16
13 9/16
5
12
5 3/4
12 3/4
7 3/8
14 3/8
Rod
Centers
(RC)
7 1/8
4 3/8
4 3/8
7 1/2
7 1/2
9 1/2
6 1/8
6 1/8
5 1/2
9 1/2
7 1/8
3
Carrier Installation
A
1
A
H
B
B
2
B
13
H
FV
UT
FRH
D42521-002 © 04-2010
FF
4
3
A
6
1
A
A
A
13
A
2
3
3"
2"
7
A
A
4
H
B
B
B
13
5
A
8
D42521-002 © 04-2010
A
A
2
1
3/8"
5
9
FV
10
W
12"
RC
12"
R
D
0 (FF)
0 - 7.85"
1
10
min
2 A
D42521-002 © 04-2010
. 12
"
6
2
B
3 - 13"
2
1
1
1
3
2
3
1
2
D42521-002 © 04-2010
4
1
2
7
1
Water supply
connection
NPT 1/2"
2
3
ASSE 1001 listed Atmospheric
Vacuum Breaker (included)
Watts 288/89A
or Chicago Faucets 892-CP
NPT1/2"
6" min. distance
between highest point
of fixture OR
as required by
local code
NPT1/2"
NPT 1/2"
NPT1/2"
Contact
Geberit
2100 Clearwater Drive, Des Plaines, IL 60018-5999
www.geberit.us
Phone: (847) 803 5000 • Fax: 847/803-5454
For Technical Assistance 800 / TEC-TRUE (800-832-8783)
8
D42521-002 © 04-2010
4

Similar documents

Geberit Outlet Valves

Geberit Outlet Valves both snap-in catches together. Lift out the flush valve.

More information

Geberit Inlet Valves

Geberit Inlet Valves diaphragm and lever part can be easily removed without tools for cleaning. The spare part is supplied as a kit (diaphragm, insert, cover and lever) in one package. The rear-entry hose is also avail...

More information