VACQ xFlat - TMI
Transcription
VACQ xFlat - TMI
Temperature data logger VACQ xFlat Measures temperature at various points for the control of thermal processes. In order to fit into flat access furnaces, TMI-Orion has designed VACQ xFlat, particularly appreciated when monitoring temperature in dry heat processes. It is protected by a thermal shield when temperature exceeds +150°C. VACQ xFlat 1.4 • 4 thermocouple channels, 1 internal reference channel and 1 reference channel for cold junction VACQ xFlat 1.8 • 8 thermocouple channels, 1 internal reference channel and 1 reference channel for cold junction VACQ xFlat 2.4 • 2 x 4 thermocouple channels, 1 internal reference channel and 1 reference channel for cold junction VACQ xFlat 2.8 • 2 x 8 thermocouple channels, 1 internal reference channel and up to 3 reference channels for cold junction Operating range 0°C to +140°C or -55°C to +140°C (peaks at +150°C). For temperatures beyond 140°C, thermal protection upon request. ● Batteries to be used according to logger operating range ● ● Models Number of thermocouples from 0 to 140°C from -55 to 140°C VACQ xFlat 1.4 4 VXP1 VACQ xFlat 1.8 8 VXP3 VACQ xFlat 2.4 8 (2 rows of 4) VXP1 VXP2 16 (2 rows of 8) VXP3 VXP3HC VXP2 VACQ xFlat 2.8 It is possible to change batteries on the same logger to have extended temperature range. Option: Power adaptator supplied with VXPS battery (0° to 70°C). Calibration uncertaineties: +/- 0.1°C from 0°C to +140°C The specified uncertainties correspond to two standard deviation.The uncertainties are calculated taking into account the various significant error sources,including the calibration probes, the equipments, the environmental conditions, the influence of the logger, repeatability, etc… ● Each logger can be calibrated and checked at the temperature points needed by the user. ● Temperature resolution and noise: 16 bit converter, resolution : <±0,1 °C ● Type K thermocouple (full scale +1300°C), type T thermocouple (full scale +400°C), other types upon request (J, N, …) ● TO/DS/100201.ed6 Metrology VACQ xFlat Technical specifications ● ● Material: 316 L stainless steel for the loggers body. Dimensions: VACQ xFlat 2.8: (L x H x W.): 153 mm x 20 mm x 80 mm VACQ xFlat 1.8: (L. x H. x W.): 153 mm x 11mm x 80 mm VACQ xFlat 2.4: (L. x H. x W.): 82 mm x 21 mm x 107 mm VACQ xFlat 1.4: (L. x H. x W.): 82 mm x 11mm x 107 mm Up to 16 connected thermocouple elements, up to 3 platinum sensors as reference channel for cold junction and and internal temperature of the electronics. ● Thermocouple upon request (K, T, N,...). ● Memory capacity: - 16 channels: 13 700 acquisitions per thermocouple channel - 8 channels: 26 100 acquisitions per thermocouple channel - 4 channels: 43 600 acquisitions per thermocouple channel ● Programmable acquisition rate: minimum 1 second, maximum 59 minutes and 59 seconds. ● Programmable acquisition duration. ● Programmable recording start by date, hour, minute. ● User replaceable high temperature battery. ● Non volatile memory (EEPROM). ● Battery autonomy : depends on acquisition rate and conditions of use. • 350 hours for a 5-second rate (battery VXP1 and VXP3) • 80 hours for a 1-second rate (battery VXP1 and VXP3) ● ● Data transfer with a communication interface connected to a USB port. Operates under Windows® XP (SP3)/VISTA/7/8. ● Data management software TMI-ORION (logger set-up, reading of records...) ● ● NOTA : Annual maintenance is recommended for calibration and adjustment. TO/DS/100201.ed6 Software operating conditions Compliant with regulations EN 61326-1 : 2006, FCC Part 15, ICES 001. TMI-ORION - Parc de Bellegarde - Bât. C - 1, chemin de Borie - 34170 Castelnau-le-Lez - FRANCE Tel +33 (0)4 99 52 67 10 - Fax +33 (0)4 99 52 67 19 - www.tmi-orion.com TMI-USA - 11491 Sunset Hills Rd., Suite 310 - Reston, VA 20190 - USA Tel +1 703 668 0114 - Fax +1 703 668 0118 - www.tmi-orion.com VACQ xFlat FullRadio Option Real time data: wireless and contactless communication VACQ xFlat FullRadio loggers are entirely autonomous. They are equipped with thermocouple sensors and do not require any wire connection. They offer the following functionalities: - wireless and contactless remote setup, starting and reading of data, - radio recording and transmitting of data during measurement, - starting and/or stopping the recording (or radio transmission) on a date. VACQ xFlat FullRadio loggers use the technology based on the IEEE 802.15.4 standard, which enables the management of numerous loggers simultaneously. All VACQ xFlat are available with FullRadio option. ● ● Radio transmission 0°C to +140°C or -55°C to +140°C (peaks at +150°C). For temperatures beyond 140°C, thermal protection upon request. Connectable antenna models for VACQ xFlat: - Standard antenna: length 49 mm, medium range (25 meters in clear field). - Short antenna: length 25 mm, short range (15 meters in clear field). - Long antenna: length 79 mm, long range (30 meters in clear field). - Possibility to use a remote antenna for the VACQ xFlat FullRadio A preliminary test is recommended to validate the hertzian transmission in the user’s application. ● ● ZigBeeBase transmitter with connectable antenna. Optional remote antenna for sterilizators. ● Connection of the ZigBeeBase radio transmitter with one of the following: - USB, - RS485 long distance, - Ethernet connection. ● Frequency: ISM 2.4 GHz (2.405 GHz to 2.475 GHz) bandwidth. This bandwidth can be used without license (industrial, scientific or medical devices). ● Output power: maximum 5 dBm (3.2 mW) ● VACQ xFlat FullRadio is compliant with the following regulations: EN 61326-1 : 2006, ETSI EN 301 489-17:2009 V2.1.1, EN 300 328 V1.7.1, EN 60950-1: 2006, FCC Part 15, ICES 001. TMI-ORION - Parc de Bellegarde - Bât. C - 1, chemin de Borie - 34170 Castelnau-le-Lez - FRANCE Tel +33 (0)4 99 52 67 10 - Fax +33 (0)4 99 52 67 19 - www.tmi-orion.com TMI-USA - 11491 Sunset Hills Rd., Suite 310 - Reston, VA 20190 - USA Tel +1 703 668 0114 - Fax +1 703 668 0118 - www.tmi-orion.com TO/DS/100201.ed6 Operating range