NKE/PMS-Katalog/GB mit Bund
Transcription
NKE/PMS-Katalog/GB mit Bund
( Patient Monitoring Accessories ) ( A l ways P e r f e c t l y B a l a n c e d : O r i g i n a l a c c e s s o r i e s fo r o pt i m a l ex a m i n a t i o n r e s u l t s ) Your patient is unique. Our accessories are original. Health is man’s most valuable asset and therefore products that help to preserve health are not to be equated with any other possessions. Espousing this philosophy is something we consistently do, since we concentrate exclusively on the development, manufacture, marketing and servicing of medical devices — an activity we discharge not as a medical department or an enterprise sector within a large concern with many business areas, but rather in our capacity as a large, internationally reputed specialist enterprise for this specialist domain. We are therefore able to target all our decision-making processes precisely towards elucidating what is necessary and beneficial for this sensitive medical electronics market. In our view there is always a direct link between technical and methodical innovations when it comes to research and development of the latest technologies. Only the synthesis of these two components will ensure that the human being will really be the final focus of all efforts. Only those devices that, in addition to optimal technology, are able to assure enhanced patient friendliness, ease of operation and diagnostic accuracy will be placed on the market. The direct interface to the patient is an essential feature of our highlydeveloped medical devices and systems. The method of signal acquisition plays a pivotal role in collecting the requisite information for successful diagnosis and therapy. We supply a comprehensive range of accessories and consumable materials for each of our products. These are developed, tested and manufactured together with the corresponding devices and are thus precisely tailored to their technical requirements. This is because the quality and reliability of medical devices and systems are inextricably bound up with the quality and reliability of the accessories used. Only the use of original accessories guarantees optimal examination results and makes an important contribution towards ensuring that your device will continue to function impeccably and reliably even in years to come, while preserving the device’s features and functional capabilities. With this catalogue we would now like to give you an overview of our accessories and consumable materials. I am delighted to have the pleasure of presenting this catalogue to you and hope to have gained your interest in the products behind this quality philosophy! Yours sincerely, Dirk Mehlhorn Head of Department for Technology and Quality Assurance 3 Highest Safety and Quality Standards Our safety guide Anyone manufacturing medical devices and accessories must have complete faith in the technology, quality and reliability of their products. Prolonged trial phases, continuous quality checks and state-of-the-art production facilities are indispensable prerequisites here. This is because the target being aspired to is: absolute reliability, error-free operation – especially during those decisive seconds. NIHON KOHDEN has already taken appropriate in-depth measures here. The national and international test standards regulating medical devices are stringent — but often not sufficiently stringent as far as we are concerned. If we believe that the state-ofthe-art permits and warrants the use of even more exacting standards, then we shall let these guide us. Quality Assurance in Practice A comprehensive quality assurance system ensures that each of the more than 3,000 NIHON KOHDEN staff members makes his/her contribution towards development, manufacture, marketing and customer services such that maximum product quality is guaranteed. NIHON KOHDEN is certified as per ISO 9001:2000, JIS Q 9001:2000, ISO 13485:1996, ISO 14001:1996, JIS Q 14001:1996 and ISO 13488:2001. 4 Trailblazers in Medical Technology A lighthouse stands supreme, showing others the way. With the symbolic light beam of our stylised lighthouse, we express our claim as well as our sense of assurance of standing supreme, while at the same time playing a trailblazing role. As one of the leaders in innovation and technology we have specialized exclusively in the field of medical technology. Here we feel committed to progress in medicine. Here we have our core competence. Here, in the services of health, we find trailblazing solutions in the domains of • Neurology • Cardiology • Patient monitoring • Haematology Fighting Disease with Electronics NIHON KOHDEN shares with you a common goal: »Fighting Disease« – for the health and quality of life of all patients. To that effect, we support your everyday activities »with Electronics« – with technical product innovations in line with the latest innovations in medical technology. NIHON KOHDEN is active in research and development. The main focus of our activities is on permanently improving diagnostic facilities. We develop all devices for and together with our clients – in the services of the patient. Your requirements and experiences gleaned from everyday practice always serve as the cornerstone of our efforts. You are our yardstick when developing new systems and technologies — from the most minute technical detail right up to the complex system solution. NIHON KOHDEN is Tradition and Future at the same time. With our competence spanning more than 50 years, our various technological innovations and ideas, we shall continue to be a strong partner for you in the future too. Allow yourself to be convinced of the quality and functional capabilities of our products, services and enterprise. 5 ( I n n ova t i o n s · H i g h l i g h t s ) CapONE – CO2 Main stream sensor for capnography Multi-parameter connection NIHON KOHDEN patient monitors are equipped with innovative multi-parameter connectors. This unique technology offers high flexibility in terms of parameter selection. The multi-parameter connector automatically detects the sensor cable connected and independently configures the patient monitor in accordance with the related parameter. CapONE – innovative and extraordinary in monitoring non-intubated patients: No module needed – CapONE is a main stream sensor and does not extract a gas sample from the patient’s respiratory flow. High signal quality – CapONE measures close to the patient. Its quality is particularly demonstrated in low-flow respiration and oral breathing. Extensive patient safety – CapONE needs no gas sampling line. This reduces the risk of infection posed to the patient as a result of a potentially contaminated gas sampling tube. BluPRO® Sensors for SpO2 Measurement Thanks to the consistent further development of its SpO2 sensor technology, NIHON KOHDEN is once again able to demonstrate with the BluPRO® series of probes just how precise and stable measurement results can be when measuring arterial oxygen saturation. Thanks to the parallel mounting of the sensor components, the reusable SpO2 sensor fits comfortably on any finger. Moreover, the mechanical design provides for exact alignment of the optical components in respect of each other and external light is effectively shielded out. The sensors are water tight and insensitive to disinfectants. The underlying philosophy when developing the single-use SpO2 sensors was precise positioning of LED and photodetector. Therefore the two optical components are designed with mechanical separation. The paediatric version of the sensors features an additional child-friendly motif series. 6 Contents ECG and Respiration Connection cables ECG electrodes Respiration (thermistor respiration measurement) 9 to 13 10 11 to 13 13 SpO2 Measurement SpO2 connection cord Reusable SpO2 probes Disposable SpO2 probes 14 to 17 15 16 17 Temperature Measurement 18 to 19 Non-invasive Blood Pressure (NIBP) Hoses Cuffs (reusable, latex-free) Disposable cuffs 20 to 23 21 22 23 Invasive Blood Pressure (IBP) 24 to 25 Cardiac Output (CO) 26 to 27 Capnography Main stream method CO2 calibration gas Side stream method 28 to 32 29 to 31 31 32 FiO2 Measurement and Measurement of Anaesthetic Gas FiO2 measurement Measurement of anaesthetic gas 33 to 35 34 34 to 35 Dye Densitograph Dye Sensors 36 to 37 37 37 Other Accessories Power cable Cleaning pen Touch pen Connection cable for external equipment 38 to 39 39 39 39 39 Batteries Batteries Battery charger (external) 40 to 41 41 41 Recording Paper 42 to 43 Accessories for Telemetry Transmitter ECG electrode leads ECG electrodes Reusable SpO2 probes Disposable SpO2 probes Cuffs (reusable, latex-free) Bags 44 to 50 45 46 to 47 48 49 50 50 Warranty/Remarks 51 to 52 Index as per Supply Code No./Article No. 53 to 54 7 Overview of our Patient Monitoring Systems The original accessories in this catalogue are optimally tailored to our patient monitors — for reliable examination results and error-free operation of your equipment for many years to come. 8 BSM-2300 BSM-4100 BSM-5100 BSM-9510 BSS-9800 OPV-1500 WEP-4200 WEP-8400 DDG-2001 ZB-810/811 ZB-820/823 ZB-930, ZS-930, ZM-930 ZB/ZS-910/920, ZM-920 ZS-940 ( ECG and Respiration ) Connection cables · page 10 ECG electrodes · page 11 to 13 Respiration (thermistor respiration measurement) · page 13 9 BR-903P Electrode lead for 3 electrodes · clip type · cable length 0.8 m Quantity DDG-2001 WEP-4200/WEP-8400 OPV-1500 Lifescope N BSM-9800 Lifescope S BSM-9510 Lifescope M R x x x x x x 1* – 1 • K910A BR-913P Electrode lead for 3 electrodes · snap type · cable length 0.8 m R x x x x x x 1* – 1 • K912 BR-906P Electrode lead for 6 electrodes · clip type · cable length 0.8 m R x x x x x – 1* – 1 • K915 BR-916P Electrode lead for 6 electrodes · snap type · cable length 0.8 m R x x x x x – 1* – 1 • K922 JC-906P Connection cord for connecting electrode lead K910, K911, K912 and K915 to patient monitor · cable length 3.0 m R x x x x x – 1* – 1 • L060 JC-103T Connection cord for connecting electrode lead K910 and K911 to patient monitor · cable length 3.0 m R – – – – – x 1* – 1 • K901 BJ-900P ECG patient cable for 12 channel ECG · comprising electrode lead and connection cord · cable length 3.8 m R – x x x x – 1* – 1 • K921 JC-900P ECG patient cable for 12 channel ECG · for connection of disposable electrodes with DIN type connector (touch-proof) · cable length 3.0 m R – x x x x – 1* – 1 ECG connection cord cover for K922 connection cord R x x x x x – 1* – 1 • 6124-039432 [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies [1*] = see also section Accessories for Telemetry Transmitter [1] [1] [2] [2] [1] K910A | [2] K911 [1] K915 | [2] K912 K922 L060 K901 K921 6124-039432 10 BSM-5100 Lifescope A BSM-4100 Lifescope P BSM-2300 Lifescope i/L Description Article No. • K911 Disposable/Reusable/ Supplies Connection Cables Supply Code No. ECG AND RESPIRATION ECG and Respiration (Impedance Method) BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity D-90 Vitrode D · disposable ECG electrode · electrode material: D Ag/AgCl · size: ca. 55 mm dia · applicable for X-ray, CT and MRT · patent pending electrode adhesive (2-dimensional elastic for tension) · very kind to the skin · suitable for long term measurements (> 72 h) · wash-, shower- and bath-tolerant · for universal use x x x x x x 1* – 30 x 3 • G207 L-150X Vitrode L · disposable ECG electrode · electrode material: D Ag/AgCl · size: ca. 35 mm dia · applicable for X-ray, CT and MRT · strong adhesive · resistant against detachment by solvents · foam tape · for universal use x x x x x x 1* – 5 x 30 • G210C F-150S Vitrode F · disposable ECG electrode (small) · electrode material: Ag/AgCl · size: ca. 18 mm x 36 mm · cotton tape · electrically conductive adhesive gel · repeatedly positionable · very kind to the skin · very suitable for children · not for use in operating rooms D x x x x x x 1* – 50 x 3 • G210D F-150M Vitrode F · disposable ECG electrode (medium) · electrode material: Ag/AgCl · size: ca. 25 mm x 45 mm · cotton tape · electrically conductive adhesive gel · repeatedly positionable · very kind to the skin · not for use in operating rooms D x x x x x x 1* – 50 x 3 • G201 Bs-150 Vitrode Bs · disposable ECG electrode · electrode material: Ag/AgCl · size: ca. 47 mm x 47 mm · soft breathable cotton tape with an elastic quality for tension · hydro gel for low electrode impedance and stable measurements even on dry skin · for universal use D x x x x x x 1* – 30 x 5 • G204 C-150 Vitrode C · disposable ECG electrode · electrode material: Ag/AgCl · size: ca. 47 mm x 47 mm · soft breathable cotton tape with an elastic quality for tension · hydro gel for low electrode impedance and stable measurements even on dry skin · the electrode gel is almost removed after removing the electrode · for universal use D x x x x x x 1* – 30 x 5 Disposable/Reusable/ Supplies Description • G217 Supply Code No. Article No. ECG Electrodes ECG AND RESPIRATION ECG and Respiration (Impedance Method) [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies [1*] = see also section Accessories for Telemetry Transmitter G217 G207 G210C G210D G201 G204 Disposable accessories can be used only once. Do not use disposable accessories repeatedly! 11 ECG Electrodes BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity J-150 Vitrode J · disposable ECG electrode · electrode material: D Ag/AgCl · size: ca. 40 mm dia · foam tape with excellent adhesion unaffected by the effects of sweat or solvents · hydro gel for low electrode impedance and stable measurements even on dry skin · the electrode gel is almost removed after removing the electrode · for universal use x x x x x x 1* – 30 x 5 • G272A V-090M3 Vitrode V · disposable ECG electrode · electrode material: D Ag/AgCl · size: ca. 25 mm x 45 mm · DIN type connector (touch-proof) with 100 cm electrode lead · electrode and cable applicable for X-ray, CT and MRT · conductive hydro gel with excellent adhesive advantages · foam and cotton tape · for universal use · 3 electrodes for ECG monitoring · coloured cable (red, yellow, green) x x x x x x – – 30 x 3 • G272B V-040M4 Vitrode V · disposable ECG electrode · same as G272A, but with 4 electrodes for limb leads · coloured cable (red, yellow, green, black) D x x x x x x – – 10 x 4 • G272C V-060M6 Vitrode V · disposable ECG electrode · same as G272A, but with 6 electrodes for chest leads · coloured cable (red, yellow, green, brown, black, purple) D x x x x x x – – 10 x 6 • G271K V-120SK Vitrode V-s · disposable ECG electrode · electrode material: D Ag/AgCl · size: ca. 20 mm x 20 mm · DIN type connector (touch-proof) with 60 cm electrode lead · electrode and cable applicable for X-ray, CT and MRT · foam and cotton tape with excellent adhesive advantages · very kind to the skin · very small – for neonates and infants · child friendly with motif print »Kitty« · coloured cable (red, yellow, green) x x x x x x – – 40 x 3 • G271A V-120S3 Vitrode V · disposable ECG electrode · same as G271K, but without motif print x x x x x x – – 40 x 3 • G250 [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies [1*] = see also section Accessories for Telemetry Transmitter 12 Disposable/Reusable/ Supplies BSM-9510 Lifescope M G271A BSM-5100 Lifescope A G271K BSM-4100 Lifescope P G272C BSM-2300 Lifescope i/L G272B Description G272A Article No. G250 Supply Code No. ECG AND RESPIRATION ECG and Respiration (Impedance Method) D Disposable/Reusable/ Supplies BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity Description Article No. Supply Code No. ECG Electrodes D x x x x x x 1* – 10 x 3 D x x x x x x 1* – • G300A N-03IS3 Vitrode N · disposable ECG electrode · electrode material: Ag/AgCl · size: ca. 14 mm x 25 mm · DIN type connector (touch-proof) with 60 cm electrode lead · electrode and cable applicable for X-ray, CT and MRT · fleece tape with excellent adhesive advantages · very kind to the skin · very small – for neonates and infants · child friendly with motif print »Sweezy« · coloured cable (red, yellow, green) • NKD-H34SG 30 Disposable ECG electrode ARBO® · size: ca. 45 mm dia · applicable ECG AND RESPIRATION ECG and Respiration (Impedance Method) · Respiration (Thermistor Respiration Measurement) for X-ray, CT and MRT · hydro gel · very strong adhesive · 72 h endurance test · shower- and wash-tolerant · with skin remover [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies [1*] = see also section Accessories for Telemetry Transmitter G300A NKD-H34SG BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity x x x x x – – – 1 • P902 TR-910P R x x x x x – – – 1 • V911 YG-001P Airway adapter for respiration pickup P902 D x x x x x – – – 1 Description Disposable/Reusable/ Supplies TR-900P Respiration pickup for air flow measurement · placed at the nose · R applicable for spontaneous breathing patients · cable length 3.0 m Article No. • P901 Supply Code No. BSM-2300 Lifescope i/L Respiration (Thermistor Respiration Measurement) Respiration pickup for air flow measurement · applicable for artificially respirated patients · Airway adapter V911 is needed · cable length 3.0 m [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies P901 P902 Disposable accessories can be used only once. Do not use disposable accessories repeatedly! V911 13 ( SpO2 Measurement ) SpO2 connection cord · page 15 Reusable SpO2 probes · page 16 Disposable SpO2 probes · page 17 14 Description Disposable/Reusable/ Supplies BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity • K931 JL-900P SpO2 connection cord · for connecting SpO2 probes to the patient monitor · with protective cap for probe connector · cable length 2.5 m R x x x x x – – – 1 • L311 JL-302T SpO2 connection cord · for connecting SpO2 probes to the patient monitor · with protective cap for probe connector · cable length 2.5 m R – – – – – x – – 1 Supply Code No. Article No. SpO2 Connection Cord S p O2 M E A S U R E M E N T SpO2 Measurement [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies K931 L311 1972 Development of Measurement Method for the Pulsoximetry (SpO2 Measurement) The method for determination of arterial oxygen saturation, based on the photoelectric plethysmography, was conceptualised and implemented in 1972 by the Japanese bio-engineer Takuo Aoyagi (NIHON KOHDEN Corporation). This idea came about while using an ear densitometer for recording dilution curves for dyes (pigments). The first commercial oximeter »OLV-5100« was presented by NIHON KOHDEN back in 1975. This method has been used worldwide since the late 1970s and has since then been further refined by many manufacturers. The NIHON KOHDEN SpO2 sensors of the BluPRO®-Series are at the cutting edge of this progressive technology. Disposable accessories can be used only once. Do not use disposable accessories repeatedly! 15 BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity Finger probe · for adults and children with a weight of more than 20 kg · cable length 1.6 m R x x x x x – 1* – 1 • P225F TL-201T Finger probe BluPRO® series · for adults and children with a weight of more than 20 kg · cable length 1.6 m R x x x x x x 1* – 1 • P225G TL-220T Multi-site probe BluPRO® series · for adults and children with R a weight of more than 3 kg · cable length 1.6 m x x x x x x 1* – 1 • P205A TL-260T Multi-site Y probe · for neonates and infants (semi disposable) · R cable length 1.6 m x x x x x x 1* – 5 R x x x x x x 1* – 1 • P260A 6143-011854 Sponge attachment tape S for multi-site Y probe P205A S x x x x x x 1* – 24 • P260B 6143-011863 Sponge attachment tape L for multi-site Y probe P205A S x x x x x x 1* – 24 • P256 Description • P224A TL-101T Article No. Disposable/Reusable/ Supplies Reusable SpO2 Probes Supply Code No. S p O2 M E A S U R E M E N T SpO2 Measurement 6143-012434 Ear clip for multi-site Y probe P205A (no illustration) [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies [1*] = see also section Accessories for Telemetry Transmitter P224A 16 P225F P225G P260A P260B P205A S p O2 M E A S U R E M E N T SpO2 Measurement Disposable SpO2 Probes [1] [1] [2] [2] [3] BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity D x x x x x x 1* – 5 • P201B TL-252T Disposable probe BluPRO® series for finger or toe · for children with a weight between 3 kg and 40 kg · cable length 1.6 m D x x x x x x 1* – 5 • P201A TL-251T Disposable probe BluPRO® series for finger or toe · for adults D with a weight of more than 30 kg · cable length 1.6 m x x x x x x 1* – 5 • P229A TL-061S Disposable probe · for adults and children with a weight between 15 kg and 50 kg (finger probe) and/or children with a weight between 3 kg and 15 kg (toe probe) · cable length 0.8 m D x x x x x x 1* – 5 • P229B TL-062S Disposable probe · same as P229A, but cable length 1.6 m D x x x x x x 1* – 5 • P228A TL-051S Disposable probe · for adults with a weight more than 50 kg (finger probe) and/or neonates with a weight less than 3 kg (foot probe) · cable length 0.8 m D x x x x x x 1* – 5 • P228B TL-052S Disposable probe · same as P228A, but cable length 1.6 m D x x x x x x 1* – 5 • P259 COTTONY tape for fixing the disposable probes S x x x x x x 1* – 20 340703 Description Disposable probe BluPRO® series for foot · for infants with a weight of less than 3 kg · cable length 1.6 m Article No. • P201C TL-253T Supply Code No. BSM-4100 Lifescope P P259 BSM-2300 Lifescope i/L [1] P228A | P228B | [2] P229A | P229B Disposable/Reusable/ Supplies [1] P201A | [2] P201B | [3] P201C [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies [1*] = see also section Accessories for Telemetry Transmitter BluPRO®-SpO2 Sensors The sensors of the BluPRO® series are water tight, so you can clean them under running water or even immerse them in a soapy alkaline or disinfectant solution (glutaraldehyde solution 2.0 % or hydrochloric alkyl diaminoethylene glycine 0.5 %)! In the finger version of the sensor, the sensor upper and lower shells are mounted in parallel thus, providing, on the one hand, exact alignment of the optical sensor components vis-à-vis one another and, on the other hand, markedly enhanced comfort during longterm wear. In addition, flexible lateral flaps shield out external light, thus preventing corruption of the measuring signals as a result of additional artificial light sources! The single-use versions place special emphasis on exact positioning of LED and photodetector. For this reason the two optical components are designed separately and can thus be brought into precise alignment with each other by the user. The outcome of these myriad innovative detailed solutions is more precise and more stable measurement results. Disposable accessories can be used only once. Do not use disposable accessories repeatedly! 17 ( Te m p e r a t u r e M e a s u r e m e n t ) Temperature measurement · page 19 18 BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity Temperature sensor for adults (esophagus, rectum) · 6.3 mm Ø miniature jack · cable length 3.5 m R x x x x x – – – 1 • NKD-P241A Temperature sensor for children (esophagus, rectum) · 6.3 mm Ø miniature jack · cable length 3.5 m R x x x x x – – – 1 • NKD-P242A YSI-409A Temperature sensor for body surface · 6.3 mm Ø miniature jack · cable length 3.5 m R x x x x x – – – 1 • K961 Connection cable for temperature sensors · for connecting of two temperature sensors with 6.3 mm Ø miniature jacks to a multi-parameter socket · cable length 0.3 m R – x x x x – – – 1 Probe cover for temperature sensor NKD-P240A (illustration similar to NKD-P249S) D x x x x x – – – 10 Probe cover for temperature sensor NKD-P240A D x x x x x – – – 100 Probe cover for temperature sensor NKD-P241A (illustration similar to NKD-P249S) D x x x x x – – – 100 Article No. Description • NKD-P240A YSI-401 Supply Code No. Disposable/Reusable/ Supplies Temperature Measurement YSI-402 JT-900P • NKD-P249 • NKD-P249S ASR618a • NKD-P249M ASR618 TEMPERATURE MEASUREMENT Temperature Measurement [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies [1] K961 NKD-P249S [2] [3] [1] NKD-P242A | [2] NKD-P241A [3] NKD-P240A Disposable accessories can be used only once. Do not use disposable accessories repeatedly! 19 ( N o n - i nva s i ve B l o o d P r e s s u r e ( N I B P ) ) Hoses · page 21 Cuffs (reusable, latex-free) · page 22 Disposable cuffs · page 23 20 BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity R x x x x x – – – 1 • S902 YN-901P Hose for cuffs for adults and children · NK bayonet joint · double hose system · hose length 3.5 m R x x x x x – – – 1 • S904 YN-920P Hose for disposable cuffs for neonates · cone joint · double hose system · hose length 1.5 m R x x x x x – – – 1 • S905 YN-921P Hose for disposable cuffs for neonates · cone joint · double hose system · hose length 3.5 m R x x x x x – – – 1 • S929A YN-100T Hose for cuffs for adults and children · NK bayonet joint · double hose system · hose length 1.5 m R – – – – – x – – 1 • S929B YN-101T Hose for cuffs for adults and children · NK bayonet joint · double hose system · hose length 3.5 m R – – – – – x – – 1 • S930A YN-120T Hose for disposable cuffs for neonates · cone joint · double hose system · hose length 1.5 m R – – – – – x – – 1 • S930B YN-121T Hose for disposable cuffs for neonates · cone joint · double hose system · hose length 3.5 m R – – – – – x – – 1 • S903 R x x x x x x – – 1 Description YN-900P Hose for cuffs for adults and children · NK bayonet joint · double hose system · hose length 1.5 m Article No. • S901 Supply Code No. Disposable/Reusable/ Supplies Hoses YN-990P Extension hose · to extend the hoses S901, S902, S929A and S929B with NK bayonet joint · hose length 1.5 m NON-INVASIVE BLOOD PRESSURE Non-invasive Blood Pressure (NIBP) [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies [2] [1] [2] [1] [1] S901 | [2] S902 [1] S904 | [2] S905 S929A | S929B S930A | S930B Disposable accessories can be used only once. Do not use disposable accessories repeatedly! S903 21 NON-INVASIVE BLOOD PRESSURE Non-invasive Blood Pressure (NIBP) Cuffs (reusable, latex-free) [6] [5] [1] [2] [3] [4] BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity x x x x x x – – 1 • S943B YP-961T R x x x x x x – – 1 • S943C YP-962T Cuff for children · width 10 cm · for circumference of 15 – 23 cm · R latex-free · NK bayonet joint on 15 cm connection hose · Velcro fastening x x x x x x – – 1 • S944B YP-963T Cuff for adults · width 13 cm · for circumference of 21 – 30 cm · latex-free · NK bayonet joint on 15 cm connection hose · Velcro fastening R x x x x x x – – 1 • S944C YP-964T Cuff for adults · width 15 cm · for circumference of 26 – 36 cm · latex-free · NK bayonet joint on 15 cm connection hose · Velcro fastening R x x x x x x – – 1 • S944D YP-965T Cuff for adults · width 19 cm · for circumference of 33– 45 cm · latex-free · NK bayonet joint on 15 cm connection hose · Velcro fastening R x x x x x x – – 1 Description R Article No. • S943A YP-960T Cuff for infants · width 5 cm · for circumference of 8 –13 cm · latex-free · NK bayonet joint on 15 cm connection hose · Velcro fastening Supply Code No. Disposable/Reusable/ Supplies [1] S943A | [2] S943B | [3] S943C | [4] S944B | [5] S944C | [6] S944D Cuff for children · width 7 cm · for circumference of 12 –18 cm · latex-free · NK bayonet joint on 15 cm connection hose · Velcro fastening [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies 22 BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity Cuff for neonates · width 2.5 cm · cone joint on 15 cm connection hose D x x x x x x – – 10 • YP-921P Cuff for neonates · width 3 cm · cone joint on 15 cm connection hose D x x x x x x – – 10 • YP-922P Cuff for neonates · width 4 cm · cone joint on 15 cm connection hose D x x x x x x – – 10 Cuff for neonates · width 5 cm · cone joint on 15 cm connection hose D x x x x x x – – 10 Cuff for infants · width 6 cm · NK bayonet joint on 20 cm connection hose D x x x x x x – – 20 • YP-912P Cuff for children · width 9 cm · NK bayonet joint on 20 cm connection hose D x x x x x x – – 20 • YP-913P Cuff for adults · width 12 cm · NK bayonet joint on 20 cm connection hose D x x x x x x – – 20 Cuff for adults · width 14 cm · NK bayonet joint on 20 cm connection hose D x x x x x x – – 20 Cuff for adults · width 16 cm · NK bayonet joint on 20 cm connection hose D x x x x x x – – 20 Cuff for adults · width 20 cm · NK bayonet joint on 20 cm connection hose D x x x x x x – – 20 Description Supply Code No. Disposable/Reusable/ Supplies Disposable Cuffs • YP-920P • YP-923P • YP-910P • YP-914P • YP-915P • YP-916P NON-INVASIVE BLOOD PRESSURE Non-invasive Blood Pressure (NIBP) [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies [1] [2] [3] [4] [1] YP-920P | [2] YP-921P | [3] YP-922P [1] [2] [1] YP-910P | [2] YP-912P [4] YP-923P Disposable accessories can be used only once. Do not use disposable accessories repeatedly! [1] [2] [3] [4] [1] YP-913P | [2] YP-914P | [3] YP-915P [4] YP-916P 23 ( I nva s i ve B l o o d P r e s s u r e ( I B P ) ) Invasive Blood Pressure (IBP) · page 25 24 Description Disposable/Reusable/ Supplies BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity • K951 JP-900P Connection cord for invasive blood pressure · for Becton Dickinson (Ohmeda) transducer (e.g. TP 400T) · cord length 3.5 m R x x x x x – – – 1 • K952 JP-910P Connection cord for invasive blood pressure · transduceradapter cable · for Becton Dickinson (Ohmeda) transducer (e.g. P23XL-1, P10EZ-1) · cord length 0.3 m R x x x x x – – – 1 • L901 JP-920P Connection cord for invasive blood pressure · for Baxter (Edwards) transducer · cord length 3.5 m R x x x x x – – – 1 Supply Code No. Article No. Invasive Blood Pressure INVASIVE BLOOD PRESSURE Invasive Blood Pressure (IBP) [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies K951 K952 Disposable accessories can be used only once. Do not use disposable accessories repeatedly! L901 25 ( Cardiac Output (CO) ) Cardiac Output (CO) · page 27 26 BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity x x x x – – – 1 CO extension cable · cable length 1.0 m R – x x x x – – – 1 • NKD-SP4045 684062 Inline sensor connection cable Becton Dickinson D – x x x x – – – 1 • NKD-SP5107H 680078 Thermodilution catheter Becton Dickinson 7F · length 1.1 m (no illustration) D – x x x x – – – 5 • NKD-SP5107H-IS 680077 Thermodilution catheter Becton Dickinson with inline sensor 7F · length 1.1 m (no illustration) D – x x x x – – – 5 • NKD-SP4500 680000 Inline iced injectate kit with injectate sensor housing (illustration similar to NKD-SP5045) D – x x x x – – – 4 • NKD-SP4572 680178 Room temperature injectate kit with injectate sensor housing (illustration similar to NKD-SP5045) D – x x x x – – – 5 • NKD-SP5045 680006 Injectate sensor housing for inline measurement of injectate temperature with sensor cable D – x x x x – – – 25 • SP-4035-1 Description – • K962 Article No. R Supply Code No. Disposable/Reusable/ Supplies Cardiac Output JT-950P Connection cord for catheter and temperature measurement (Baxter and Becton Dickinson) · cord length 2.0 m CARDIAC OUTPUT Cardiac Output (CO) [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies K962 SP-4035-1 NKD-SP4045 NKD-SP5045 Disposable accessories can be used only once. Do not use disposable accessories repeatedly! 27 ( C a p n o g r a p hy ) Main stream method · page 29 to 31 CO2 calibration gas · page 31 Side stream method · page 32 28 CAPNOGRAPHY Capnography BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity x x x – – – 1 R x x x x x – – – 1 R x x x x x – – – 1 YG-120T Disposable nasal adapter for CapONE · for expiratory information · rejects condensates · short starting time of 5 s only D x x x x x – – – 30 • V922 YG-121T D x x x x x – – – 30 • V923 YG-122T Disposable nasal adapter with O2 tube for CapONE · for expiratory information · rejects condensates · during supply of O2 with face mask or O2 tube the capnogram can be constantly displayed without any distortion D x x x x x – – – 30 Description Disposable/Reusable/ Supplies x Article No. x Supply Code No. BSM-2300 Lifescope i/L Main stream Method • P907 TG-920P CO2 sensor kit CapONE · it includes CO2 sensor P923 and R CO2 adapter K984 · main stream CO2 sensor for nonintubated patients · for expiratory information · new measurement technique decreases the number of false alarms · for connection to a multi-parameter socket · includes data processing hardware · maintenance-free · cable length 3.5 m • P923 TG-921T CO2 sensor CapONE · for non-intubated patients · for expiratory information · for connection to the CO2 adapter K984 · exceptionally shockproof · cable length 1.5 m • K984 JG-920P CO2 adapter CapONE · for non-intubated patients · for expiratory information · for connection to a multi-parameter socket · includes data processing hardware · cable length 2.0 m • V921 Disposable nasal adapter for CapONE · for expiratory information · rejects condensates [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies P907 P923 K984 V921 V922 V923 Disposable accessories can be used only once. Do not use disposable accessories repeatedly! 29 BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity x x x x – – – 1 R x x x x x – – – 1 CO2 adapter · for intubated patients · for expiratory information · for connection to a multi-parameter socket · includes data processing hardware · cable length 2.0 m R x x x x x – – – 1 Airway adapter without heater · rejects condensates · short starting time of 5 s only · 5 ml dead space volume D x x x x x – – – 50 R x x x x x – – – 1 R x x x x x – – – 1 Disposable/Reusable/ Supplies x Description Article No. Main stream Method Supply Code No. CAPNOGRAPHY Capnography • P903* TG-900P CO2 sensor kit · it includes CO2 sensor P922A and CO2 R adapter K981 · main stream CO2 sensor for intubated patients · for expiratory information · for connection to a multi-parameter socket · includes data processing hardware · maintenance-free · cable length 3.0 m • P922A TG-101T CO2 sensor · for intubated patients · for expiratory information · for connection to the CO2 adapter K981 · exceptionally shockproof · cable length 1.0 m • K981 JG-900P • R801 YG-101T • P905 TG-950P CO2 sensor kit · it includes CO2 sensor P921 and CO2 adapter K982 · for intubated patients · for inspiratory and expiratory information · for connection to a multi-parameter socket · includes data processing hardware · maintenancefree · cable length 4.0 m • P921 TG-201T CO2 sensor · for intubated patients · for inspiratory and expiratory information · for connection to the CO2 adapter K982 · exceptionally shockproof · cable length 2.0 m [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies [*] Attention during anaesthesia! Especially during the use of closed respiration circuits (CO2 returned respiration)! The sensor does not measure inspiratory CO2 concentrations! 30 P903 P922A K981 R801 P905 P921 CAPNOGRAPHY Capnography Main stream Method [2] [1] Disposable/Reusable/ Supplies BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity • K982 JG-950P CO2 adapter · for intubated patients · for inspiratory and expiratory information · for connection to a multi-parameter socket · includes data processing hardware · cable length 2.0 m R x x x x x – – – 1 • R802 YG-201T Airway adapter without heater · for adults and children with a weight of more than 10 kg · rejects condensates · short starting time of 5 s only · 5 ml dead space volume D x x x x x – – – 30 • R803 YG-202T Airway adapter without heater · for children and neonates D with a weight between 3 kg and 10 kg · rejects condensates · short starting time of 5 s only · 2 ml dead space volume x x x x x – – – 30 Supply Code No. Description [1] R802 | [2] R803 Article No. K982 [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity CO2 calibration gas · 200 g gas cylinder R x x x x x – – – 1 Flow regulator S x x x x x – – – 1 Description • NKD-CO2Gas • NKD-Ventil Supply Code No. Disposable/Reusable/ Supplies CO2 Calibration Gas [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies NKD-CO2Gas NKD-Ventil Disposable accessories can be used only once. Do not use disposable accessories repeatedly! 31 BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity • V907C YG-914P Nasal FilterLine (TM) Oridion Medical · nasal gas probe tube for non-intubated neonates · tube length 2.5 m D x x x x x – – – 25 • V907B YG-913P Nasal FilterLine (TM) Oridion Medical · nasal gas probe tube for non-intubated children · tube length 2.5 m D x x x x x – – – 25 • V907A YG-912P Nasal FilterLine (TM) Oridion Medical · nasal gas probe tube for non-intubated adults · tube length 2.5 m D x x x x x – – – 25 • NKD-006342 FilterLine (H) for neonates and infants · for use together with D humidifier · max. 72 h continuous operation · 0.5 ml dead space volume · tube length 2.0 m x x x x x – – – 25 • NKD-XS04624 FilterLine (H) for adults and children · for use together with humidifier · max. 72 h continuous operation · 7.3 ml dead space volume · tube length 2.0 m D x x x x x – – – 25 • NKD-XS04620 FilterLine (H) for adults and children · for use without humidifier · max. 6 h continuous operation · 7.3 ml dead space volume · tube length 2.0 m D x x x x x – – – 25 • V903F 618877 Microstream (TM) Airway adapter · for neonates and infants · D 0.5 ml dead space volume x x x x x – – – 25 • V903E YG-904P Microstream (TM) Airway adapter · for adults · 7.3 ml dead space volume D x x x x x – – – 25 • V901 YG-920P Exhaust gas adapter · tube length 3.0 m R x x x x x – – – 1 Article No. Description Disposable/Reusable/ Supplies Side stream Method Supply Code No. CAPNOGRAPHY Capnography [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies [1] [2] [1] V907A | [2] V907B | [3] V907C [3] [1] [1] NKD-006342 | [2] NKD-XS04624 [3] NKD-XS04620 V903E 32 [2] V901 [3] V903F ( FiO2 Measurement and Measurement of Anaesthetic Gas ) FiO2 measurement · page 34 Measurement of anaesthetic gas · page 34 to 35 33 Description Disposable/Reusable/ Supplies BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity • P911 074705 O2 sensor · coiled cord · cable length 0.6 m R – x x x x – – – 1 • K941 JO-900P Connection cable for O2 sensor · for connection to a multiparameter socket · cable length 3.0 m R – x x x x – – – 1 • V912 110774 T-adapter for O2 measurement (connection of the O2 sensor) D – x x x x – – – 1 Supply Code No. Article No. FiO2 Measurement [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies P911 K941 V912 Article No. Description Disposable/Reusable/ Supplies BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity Measurement of Anaesthetic Gas • NKD-V915B 613721 Dryline water trap · for children and neonates R – x x – x – – – 10 • NKD-V915A 613712 Dryline water trap · for adults R – x x – x – – – 10 • NKD-V916A 613739 Dryline Airway adapter · straight D – x x – x – – – 10 Supply Code No. MEASUREMENT OF ANAESTHETIC GAS FIO2 MEASUREMENT · FiO2 Measurement · Measurement of Anaesthetic Gas [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies NKD-V915B 34 NKD-V915A NKD-V916A MEASUREMENT OF ANAESTHETIC GAS Measurement of Anaesthetic Gas NKD-V916B V903E V903F NKD-V917B NKD-V917A NKD-Scottgas FIO2 MEASUREMENT · Measurement of Anaesthetic Gas • NKD-V917B • NKD-V917A 613775 613766 WEP-4200/WEP-8400 DDG-2001 Quantity 618877 OPV-1500 Lifescope N • V903F BSM-9800 Lifescope S YG-904P Microstream (TM) Airway adapter · for adults · 7.3 ml dead space volume BSM-9510 Lifescope M • V903E BSM-5100 Lifescope A Dryline Airway adapter · elbow BSM-4100 Lifescope P 613748 BSM-2300 Lifescope i/L Description • NKD-V916B Disposable/Reusable/ Supplies Article No. Supply Code No. 611358 D – x x – x – – – 10 D – x x – x – – – 25 Microstream (TM) Airway adapter · for neonates and infants · 0.5 ml dead space volume D – x x – x – – – 25 Sampling tube · for children and neonates · tube length 2.5 m D – x x – x – – – 25 Sampling tube · for adults · tube length 2.5 m D – x x – x – – – 25 • NKD-Scottgas Anaesthesia calibration gas · 1,000 ml S – x x – x – – – 1 • 611358 Flow regulator · with pressure gauge and connection tube R – x x – x – – – 1 [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies Disposable accessories can be used only once. Do not use disposable accessories repeatedly! 35 ( D ye D e n s i t o g r a p h ) Dye · page 37 Sensors · page 37 36 BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity S – – – – – – – x 5 Finger sensor R – – – – – – – x 1 Nose sensor R – – – – – – – x 1 Injection detector R – – – – – – – x 1 • P196 • TL-351P TL-321P Description Indocyanin-green · 5 x 50 mg dye • TL-301P Article No. • NKD-IC-GreenP Supply Code No. Disposable/Reusable/ Supplies Dye · Sensors DYE DENSITOGRAPH Dye Densitograph [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies [1] [2] NKD-IC-GreenP [1] TL-301P | [2] P196 Disposable accessories can be used only once. Do not use disposable accessories repeatedly! TL-351P 37 ( Other Accessories ) Power cable · page 39 Cleaning pen · page 39 Touch pen · page 39 Connection cable for external equipment · page 39 38 Disposable/Reusable/ Supplies BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity • NKD-L936 314839B Power cable · cable length 2.5 m R x x x x x x x x 1 Description Article No. Supply Code No. Power Cable · Cleaning Pen · Touch Pen · Connection Cable for External Equipment • Y011 404617 Cleaning pen for thermal head R x x x x x x x x 1 • Y075 577297A Touch pen for easy use of touch screen monitors · includes cord and touch pen holder R x x x x x x x – 1 • K974 515738 Connection cable for signal output of ECG and blood pressure · cable length 5.0 m – x x – – – – – 1 R OTHER ACCESSORIES Other Accessories [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies NKD-L936 Y011 Y075 K974 Disposable accessories can be used only once. Do not use disposable accessories repeatedly! 39 ( Batteries ) Batteries · page 41 Battery charger (external) · page 41 40 BATTERIES Batteries Description Disposable/Reusable/ Supplies BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity • X062 YS-076P5 Battery pack · 12 V, 3700 mAh · nickel metal hydride (Ni-MH) · rechargeable R x – – – – – – – 1 • X060 NKB-101 Battery pack · 12 V, 1700 mAh · nickel cadmium (Ni-Cd) · rechargeable R – x x – – – – – 1 External battery charger for battery X060 (no illustration) R – x x – – – – – 1 Supply Code No. Article No. Batteries · Battery Charger (external) • SB-201VK [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies X062 X060 Disposable accessories can be used only once. Do not use disposable accessories repeatedly! 41 ( Recording Paper ) Recording paper · page 43 42 BSM-2300 Lifescope i/L BSM-4100 Lifescope P BSM-5100 Lifescope A BSM-9510 Lifescope M BSM-9800 Lifescope S OPV-1500 Lifescope N WEP-4200/WEP-8400 DDG-2001 Quantity S x x x x x – x x 1 • A810 Thermal recording paper · roll · 60 mm x 20 m (each page 100 mm) · without grid S – – – – – x – – 1 QW60-2 Description Thermal recording paper · Z-fold book · 50 mm x 30 m (each page 100 mm) · without grid Article No. • NKD-A723 FQW50-3-100 Supply Code No. Disposable/Reusable/ Supplies Recording Paper RECORDING PAPER Recording Paper [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies Disposable accessories can be used only once. Do not use disposable accessories repeatedly! 43 ( A c c e s s o r i e s f o r Te l e m e t r y Tr a n s m i t t e r ) ECG electrode leads · page 45 ECG electrodes · page 46 to 47 Reusable SpO2 probes · page 48 Disposable SpO2 probes · page 49 Cuffs (reusable, latex-free) · page 50 Bags · page 50 44 ZB-810/ZB-811 ZB-820 ZB-823 ZB/ZS-910 ZB/ZS/ZM-920 ZB/ZS/ZM-930 ZS-940 Quantity – – – x1* x1* x 1 R – – – x1* x1* x 1 • K226 BR-019P Electrode lead for 3 electrodes · snap type · cable length 0.8 m R x – x – – – 1 • K225 BR-018P Electrode lead for 3 electrodes · clip type · cable length 0.8 m R x – x – – – 1 • K910A BR-913P Electrode lead for 3 electrodes · snap type · cable length 0.8 m R – – – x x x 1 • K911 BR-903P Electrode lead for 3 electrodes · clip type · cable length 0.8 m R – – – x x x 1 • K228 BR-021P Electrode lead for 5 electrodes · snap type · cable length 0.8 m R – x x – – – 1 • K227 BR-020P Electrode lead for 5 electrodes · clip type · cable length 0.8 m R – x x – – – 1 • K915 BR-916P Electrode lead for 6 electrodes · snap type · cable length 0.8 m R – – – x x – 1 • K912 BR-906P Electrode lead for 6 electrodes · clip type · cable length 0.8 m R – – – x x – 1 Description R • K907A BR-902P Electrode lead for 2 electrodes · clip type · cable length 0.8 m Article No. • K908A BR-912P Electrode lead for 2 electrodes · snap type · cable length 0.8 m Supply Code No. Disposable/Reusable/ Supplies ECG Electrode Leads [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies [1*] = not possible for ZM-9x0 series [1] [2] [3] [4] [1] [2] [2] [1] K908A | [2] K907A [1] [1] ACCESSORIES FOR TELEMETRY TRANSMITTER Accessories for Telemetry Transmitter [1] K225 | [2] K226 | [3] K227 | [4] K228 [1] K910A | [2] K911 [2] [1] K915 | [2] K912 Disposable accessories can be used only once. Do not use disposable accessories repeatedly! 45 Article No. Description Disposable/Reusable/ Supplies ZB-810/ZB-811 ZB-820 ZB-823 ZB/ZS-910 ZB/ZS/ZM-920 ZB/ZS/ZM-930 ZS-940 Quantity ECG Electrodes • G217 D-90 Vitrode D · disposable ECG electrode · electrode material: Ag/AgCl · size: ca. 55 mm dia · applicable for X-ray, CT and MRT · adhesive by patent pending electrode structure (2-dimensional elastic for tension) · very kind to the skin · suitable for long term measurements (> 72 h) · wash-, shower- and bath-steadily · for universal use D x x x x x x 30 x 3 • G207 L-150X Vitrode L · disposable ECG electrode · electrode material: Ag/AgCl · size: ca. 35 mm dia · applicable for X-ray, CT and MRT · strong adhesive · resistant against detachment by solvents · foam tape · for universal use D x x x x x x 5 x 30 • G210C F-150S Vitrode F · disposable ECG electrode (small) · electrode material: Ag/AgCl · size: ca.18 mm x 36 mm · cotton tape · electrically conductive adhesive gel · repeatedly positionable · very kind to the skin · very suitable for children · not for use in operating rooms D x x x x x x 50 x 3 • G210D F-150M Vitrode F · disposable ECG electrode (medium) · electrode material: Ag/AgCl · size: ca. 25 mm x 45 mm · cotton tape · electrically conductive adhesive gel · repeatedly positionable · very kind to the skin · not for use in operating rooms D x x x x x x 50 x 3 • G201 Vitrode Bs · disposable ECG electrode · electrode material: Ag/AgCl · D size: ca. 47 mm x 47 mm · soft breathing cotton tape with an elastic quality for tension · hydro gel for low electrode impedance and stable measurements even on dry skin · for universal use x x x x x x 30 x 5 Supply Code No. ACCESSORIES FOR TELEMETRY TRANSMITTER Accessories for Telemetry Transmitter Bs-150 [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies 46 G217 G207 G210D G201 G210C ECG Electrodes ZB-810/ZB-811 ZB-820 ZB-823 ZB/ZS-910 ZB/ZS/ZM-920 ZB/ZS/ZM-930 ZS-940 Quantity Disposable/Reusable/ Supplies NKD-H34SG Description G250 Article No. Supply Code No. G204 • G204 C-150 Vitrode C · disposable ECG electrode · electrode material: Ag/AgCl · D size: ca. 47 mm x 47 mm · soft breathing cotton tape with an elastic quality for tension · hydro gel for low electrode impedance and stable measurements even on dry skin · the electrode gel is nearly removed after removing the electrode · for universal use x x x x x x 30 x 5 • G250 J-150 Vitrode J · disposable ECG electrode · electrode material: Ag/AgCl · D size: ca. 40 mm dia · foam tape with excellent adhesive advantages even by effects of sweat or solvents · hydro gel for low electrode impedance and stable measurements even on dry skin · the electrode gel is nearly removed after removing the electrode · for universal use x x x x x x 30 x 5 Disposable ECG electrode ARBO® · size: ca. 45 mm dia · applicable for X-ray, CT and MRT · hydro gel · very strong adhesive · 72 h endurance test · showerand wash-steadily · with skin remover x x x x x x 30 • NKD-H34SG D ACCESSORIES FOR TELEMETRY TRANSMITTER Accessories for Telemetry Transmitter [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies Disposable accessories can be used only once. Do not use disposable accessories repeatedly! 47 ZB-810/ZB-811 ZB-820 ZB-823 ZB/ZS-910 ZB/ZS/ZM-920 ZB/ZS/ZM-930 ZS-940 Quantity Finger probe · for adults and children with a weight of more than 20 kg · cable length 1.6 m R – – – – x 1* 1 • P225F TL-201T Finger probe BluPRO® series · for adults and children with a weight of more than 20 kg · cable length 1.6 m R – – – – x 1* 1 • P225G TL-220T Multi-site probe BluPRO® series · for adults and children with a weight of more than 3 kg · cable length 1.6 m R – – – – x 1* 1 • P225H TL-201T Finger probe BluPRO® series · same as P225F, but cable length 0.6 m (illustration similar to P225F) R – – – – – x 1 • P205A TL-260T Multi-site Y probe · for neonates and infants (semi disposable) · cable length 1.6 m R – – – – x 1* 5 • P256 Ear clip for multi-site Y probe P205A (no illustration) R – – – – x 1* 1 • P260A 6143-011854 Sponge attachment tape S for multi-site Y probe P205A R – – – – x 1* 24 • P260B 6143-011863 Sponge attachment tape L for multi-site Y probe P205A R – – – – x 1* 24 6143-012434 Description • P224A TL-101T Article No. Disposable/Reusable/ Supplies Reusable SpO2 Probes Supply Code No. ACCESSORIES FOR TELEMETRY TRANSMITTER Accessories for Telemetry Transmitter [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies [1*] = because of cable length, fit for limited use P224A 48 P225F P225G P260A P260B P205A Disposable SpO2 Probes [1] [1] [2] [2] [3] ZB-823 ZB/ZS-910 ZB/ZS/ZM-920 ZB/ZS/ZM-930 ZS-940 Quantity D – – – – x 1* 5 • P201B TL-252T Disposable probe BluPRO® series for finger or toe · for children with a weight between 3 kg and 40 kg · cable length 1.6 m D – – – – x 1* 5 • P201A TL-251T Disposable probe BluPRO® series for finger or toe · for adults with a weight of more than 30 kg · cable length 1.6 m D – – – – x 1* 5 • P229A TL-061S Disposable probe · for adults and children with a weight between 15 kg and 50 kg (finger probe) and/or children with a weight between 3 kg and 15 kg (toe probe) · cable length 0.8 m D – – – – x 1* 5 • P229B TL-062S Disposable probe · same as P229A, but cable length 1.6 m D – – – – x 1* 5 • P228A TL-051S Disposable probe · for adults with a weight more than 50 kg (finger probe) D and/or neonates with a weight less than 3 kg (foot probe) · cable length 0.8 m – – – – x 1* 5 • P228B TL-052S Disposable probe · same as P228A, but cable length 1.6 m D – – – – x 1* 5 • P259 COTTONY tape for fixing the disposable probes R – – – – x x 20 340703 Description Disposable probe BluPRO® series for foot · for infants with a weight of less than 3 kg · cable length 1.6 m Article No. • P201C TL-253T Supply Code No. ZB-820 P259 ZB-810/ZB-811 [1] P228A | P228B | [2] P229A | P229B Disposable/Reusable/ Supplies [1] P201A | [2] P201B | [3] P201C ACCESSORIES FOR TELEMETRY TRANSMITTER Accessories for Telemetry Transmitter [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies [1*] = because of cable length, fit for limited use Disposable accessories can be used only once. Do not use disposable accessories repeatedly! 49 ZB-810/ZB-811 ZB-820 ZB-823 ZB/ZS-910 ZB/ZS/ZM-920 ZB/ZS/ZM-930 ZS-940 Quantity – – – – – x 1 • S938C YP-944P Cuff for adults · width 15 cm · for circumference of 26–36 cm · latex-free · NK bayonet joint on connection hose (no illustration) R – – – – – x 1 Description R Article No. • S938B YP-943P Cuff for adults · width 13 cm · for circumference of 21–30 cm · latex-free · NK bayonet joint on connection hose (no illustration) Supply Code No. Disposable/Reusable/ Supplies Cuffs (reusable, latex-free) [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies ZB-810/ZB-811 ZB-820 ZB-823 ZB/ZS-910 ZB/ZS/ZM-920 ZB/ZS/ZM-930 ZS-940 Quantity Disposable transportation bag for telemetry transmitter · with belt D x x x x – – 3 • NKD-Tasche Transportation bag for telemetry transmitter · with belt (illustration similar as NKD-Tasche1) R x x x x – – 1 • NKD-Tasche1 Transportation bag for telemetry transmitter · with belt R – – – – x – 1 • Y236 Shoulder strap (no illustration) R – – – – – x 1 Description • Y264E Article No. Disposable/Reusable/ Supplies Bags Supply Code No. ACCESSORIES FOR TELEMETRY TRANSMITTER Accessories for Telemetry Transmitter [x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies Y264E 50 NKD-Tasche1 Warranty General Warranty Regulations NIHON KOHDEN offers a one-year warranty for their products against material defects and functional breakdowns starting from the day of delivery. Excluded from this warranty are consumable materials such as recorder paper, ink and batteries. NIHON KOHDEN products in which a defect occurs during this warranty period will be repaired or replaced by NIHON KOHDEN customer services or will be repaired or replaced by the authorised specialist dealer, provided that the products were used in accordance with the instructions given in the Operating Instructions. No other persons or organisations are authorised to grant a warranty or enter into obligations for our products. NIHON KOHDEN does not recognise any other form of warranty, whether implicit or in writing. The warranty claim expires as soon as servicing measures, technical modifications or other product changes are carried out by personnel not authorised by NIHON KOHDEN or without the explicit agreement of NIHON KOHDEN. Furthermore, the warranty claim expires in the event of unauthorised opening of the device, of re-installation or repair by personnel not authorised by NIHON KOHDEN as well as in the event of removal of the rating plates, in the event of damage resulting from negligence, the use of force, or in the event of damage caused by fire, lightning, water, vandalism, force majeure or improper installation or use. Warranty for reusable SpO2 sensors The warranty period granted by NIHON KOHDEN for SpO2 sensor materials and workmanship ends 6 months after opening the packaging, but by the latest 12 months after delivery. NIHON KOHDEN or its authorised specialist dealer will repair or replace defective sensors provided that they have been used in accordance with the Instructions for Use. Please also observe our General Sales, Delivery and Payment Conditions! Despite the meticulous care taken in compiling the information for this Catalogue of Accessories, we cannot unfortunately rule out errors or mistakes! 51 Remarks Customer Number: (By quoting your customer number you will particularly help us to expedite processing of your order.) Device 52 Type Designation Serial Number Index as per Supply Code No. Supply Code No. Page 611358 35 6124-039432 10 A810 43 G201 11, 46 G204 11, 47 G207 11, 46 G210C 11, 46 G210D 11, 46 G217 11, 46 G250 12, 47 G271A 12 G271K 12 G272A 12 G272B 12 G272C 12 G300A 13 K225 45 K226 45 K227 45 K228 45 K901 10 K907A 45 K908A 45 K910A 10, 45 K911 10, 45 K912 10, 45 K915 10, 45 K921 10 K922 10 K931 15 K941 34 K951 25 K952 25 K961 19 K962 27 K974 39 K981 30 K982 31 K984 29 L060 10 L311 15 L901 25 NKD-006342 32 NKD-A723 43 NKD-CO2Gas 31 NKD-H34SG 13, 47 NKD-IC-GreenP 37 NKD-L936 39 NKD-P240A 19 NKD-P241A 19 Supply Code No. Page NKD-P242A 19 NKD-P249 19 NKD-P249S 19 NKD-P249M 19 NKD-Scottgas 35 NKD-SP4045 27 NKD-SP4500 27 NKD-SP4572 27 NKD-SP5045 27 NKD-SP5107H 27 NKD-SP5107H-IS 27 NKD-Tasche 50 NKD-Tasche1 50 NKD-V915A 34 NKD-V915B 34 NKD-V916A 34 NKD-V916B 35 NKD-V917A 35 NKD-V917B 35 NKD-Ventil 31 NKD-XS04620 32 NKD-XS04624 32 P196 37 P201A 17, 49 P201B 17, 49 P201C 17, 49 P205A 16, 48 P224A 16, 48 P225F 16, 48 P225G 16, 48 P225H 48 P228A 17, 49 P228B 17, 49 P229A 17, 49 P229B 17, 49 P256 16, 48 P259 17, 49 P260A 16, 48 P260B 16, 48 P901 13 P902 13 P903 30 P905 30 P907 29 P911 34 P921 30 P922A 30 P923 29 R801 30 R802 31 Supply Code No. Page R803 31 S901 21 S902 21 S903 21 S904 21 S905 21 S929A 21 S929B 21 S930A 21 S930B 21 S938B 50 S938C 50 S943A 22 S943B 22 S943C 22 S944B 22 S944C 22 S944D 22 SB-201VK 41 SP-4035-1 27 TL-301P 37 TL-351P 37 V901 32 V903E 32, 35 V903F 32, 35 V907A 32 V907B 32 V907C 32 V911 13 V912 34 V921 29 V922 29 V923 29 X060 41 X062 41 Y011 39 Y075 39 Y236 50 Y264E 50 YP-910P 23 YP-912P 23 YP-913P 23 YP-914P 23 YP-915P 23 YP-916P 23 YP-920P 23 YP-921P 23 YP-922P 23 YP-923P 23 53 Index as per Article No. Article No. 074705 110774 314839B 340703 404617 515738 577297A 613712 613721 613739 613748 613766 613775 6143-011854 6143-011863 6143-012434 618877 680000 680006 680077 680078 680178 684062 ASR618 ASR618a BJ-900P BR-018P BR-019P BR-020P BR-021P BR-902P BR-903P BR-906P BR-912P BR-913P BR-916P Bs-150 C-150 D-90 F-150M F-150S FQW50-3-100 J-150 JC-103T JC-900P JC-906P JG-900P JG-920P JG-950P JL-302T 54 Page 34 34 39 17, 49 39 39 39 34 34 34 35 35 35 16, 48 16, 48 16, 48 32, 35 27 27 27 27 27 27 19 19 10 45 45 45 45 45 10, 45 10, 45 45 10, 45 10, 45 11, 46 11, 47 11, 46 11, 46 11, 46 43 12, 47 10 10 10 30 29 31 15 Article No. JL-900P JO-900P JP-900P JP-910P JP-920P JT-900P JT-950P L-150X N-03IS3 NKB-101 QW60-2 TG-101T TG-201T TG-900P TG-920P TG-921T TG-950P TL-051S TL-052S TL-061S TL-062S TL-101T TL-201T TL-220T TL-251T TL-252T TL-253T TL-260T TL-321P TR-900P TR-910P V-040M4 V-060M6 V-090M3 V-120S3 V-120SK YG-001P YG-101T YG-120T YG-121T YG-122T YG-201T YG-202T YG-904P YG-912P YG-913P YG-914P YG-920P YN-100T YN-101T Page 15 34 25 25 25 19 27 11, 46 13 41 43 30 30 30 29 29 30 17, 49 17, 49 17, 49 17, 49 16, 48 16, 48 16, 48 17, 49 17, 49 17, 49 16, 48 37 13 13 12 12 12 12 12 13 30 29 29 29 31 31 32, 35 32 32 32 32 21 21 Article No. YN-120T YN-121T YN-900P YN-901P YN-920P YN-921P YN-990P YP-943P YP-944P YP-960T YP-961T YP-962T YP-963T YP-964T YP-965T YS-076P5 YSI-401 YSI-402 YSI-409A Page 21 21 21 21 21 21 21 50 50 22 22 22 22 22 22 41 19 19 19 CARDIOLOGY PATIENT MONITORING first art // Gießen NEUROLOGY Vol. 1 NIHON KOHDEN EUROPE GmbH Raiffeisenstraße 10 D-61191 Rosbach (Germany) Telefax: + 49 (0) 60 03 / 8 27-599 E-Mail: info@nke.de www.nihonkohden.com Dealer PMS-Z-e-01/05 Telephone: + 49 (0) 60 03 / 8 27-0