Dunham Bush Air-Cooled Screw Chiller | AFVX-B
Transcription
Dunham Bush Air-Cooled Screw Chiller | AFVX-B
Dunham Bush Air‐Cooled Screw Chiller AFVX‐B‐6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kW) ACDX Series 100 ~ 520TR (352 ~ 1830kW) 10 ~ 180TR (35 ~ 633 kW) AFVX-B Series ACDS Series 0 100 200 300 400 TR 500 600 700 AFVX-B-6SR Series Generation SPEC‐ Selection Program Electronic Catalogue AFVX-B-6SR Series Generation AFVX-B-6SR Series High Efficiency Fan Condenser Coil Microprocessor Controller - Low rpm & Low noise - 64-67dBA at 10 meter - V Coil Design - Inner Groove Copper tube - Aluminium Wave Fin - Advance Vision 2020i Controller - Double Door Protection - IP 55 - Factory Packaged Starter Vertical Screw Compressor - Hermetic Patented Design - Small Footprint - Multiple Compressors - Acoustically Compartmentalized Flooded Evaporator - Better Approach - High Efficiency - Inner Groove Copper tube AFVX-B-6SR Series – 13 Models (100-504RT) – Plate Heat Ex-changer Economizer – Improved & Enhanced Compressor . – 127, 192 and 226mm rotor series – Qty 1 & 2 only – 3.4hp condenser fan motor – Average at 1.175 kw/rt – 10% more efficient – Electronic Expansion Valve (EEV) – Further enhanced evaporator with new shell design – Aluminium blade fan – 900mm fan diameter – Compact footprint – Reduced height AFVX-B-6SR Series Condenser Fan Motor Sound @ 10M Model Capacity AFVX‐B TR Qty KW Qty HP L W H dB(A) 100‐6SR 99.6 1 99.5 7 3.4 4710 2235 2235 64 120‐6SR 116.0 1 119.2 7 3.4 4710 2235 2235 65 135‐6SR 132.2 1 138.4 7 3 .4 4710 2235 2235 65 165‐6SR 164.9 1 171.3 9 3.4 5860 2235 2235 65 200‐6SR 192.3 1 197.7 11 3.4 7210 2235 2368 65 225‐6SR 216.0 1 220.9 11 3 .4 7210 2235 2368 65 260‐6SR 251.9 1 257.2 13 3.4 8360 2235 2368 63 280‐6SR 278.8 2 283.1 18 3.4 11510 2235 2368 67 330‐6SR 328.7 2 342.7 18 3.4 11510 2235 2368 67 360‐6SR 359.0 2 377.9 18 3.4 11510 2235 2368 67 400‐6SR 384.6 2 395.4 22 3 .4 14420 2235 2368 75 450‐6SR 432.0 2 441.7 22 3.4 14420 2235 2368 75 520‐6SR 503.8 2 514.5 26 3 .4 16720 2235 2368 75 Compressor Dimension Compressor Location Model : AFVXB 100 – 260 Model : AFVXB 280 – 360 Compressor Location Model : AFVXB 400 – 520 Condenser Fan Cycling Option List Item Code Description 1. 2. 3. MII2 SST VM3 Main Incoming Isolator c/w Door Interlock Handle Soft Starter c/w Bypass Contactor 3 Phase Voltmeter C/W Selection Switch Yes Yes Yes 4. AM3 3 Phase Amperage Meter C/W Selection Switch Yes 5. 6. 7. UVR GFI SVM Under/Over Voltage Protection Relay Ground Fault Interrupt System Voltage Measurement No Yes Yes 8. LA1 Low Ambient Version, min. ambient 7˚C No 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. LA2 LA3 HGBP COP HYD 250 INS DINS DES ISO Low Ambient Version, min. ambient ‐10˚C Low Ambient Version, min. ambient ‐29˚C Hot Gas Bypass for low load operation‐Auto Lead Lag Copper‐Copper Condenser Coil Hydrophillic Coated Condenser Fin 250 PSI Working Pressure Vessels (Flooded) Evaporator Insulation Double Evaporator Insulation 2" Heat recovery (Desuperheater) Isolation Valves Compressor(s) Suction, Discharge & VI Yes Yes Yes Yes Yes Yes No Yes Yes No Yes Yes Yes Yes No 19. FWC1 20. GRL Flanged Water Connections Evap. Protective Grille Condenser Description NO APPROVAL ASME JKKP APPROVAL PED APPROVAL AFVXB‐5SR Option List Item Code 21. HEA 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. LN2 LN 2YC 5YC SPG RIS WFS WFS1 WFS4 IP55 PED ASME JKKP SQL CE CE DM SHC Description Heater System to Protect Cooler Against Freezing, Protected up to ‐ 20˚C Compressor(s) Acoustic Jacket Low Noise Version, including LN1 or LN2 and LN fans 2 Year Compressor Warranty 5 Year Compressor Warranty Spring Vibration Isolators Rubber‐in Rush Isolator Water Flow Switch : CE marking Water Flow Switch :NEMA1, min fluid & ambient 32ºF Water Flow Switch :NEMA4, min fluid & ambient ‐62ºF IP55 Control Panel PED coded vessels ASME coded vessels JKKP coded vessels Chinese Machinery (SQL) coded vessels PED (including piping) + CE components PED (vessel) + CE components + IEC Control Panel Dual Mode (Ice ‐Cel) Semi Hermetic Compressor Description AFVXB‐5SR Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes AFVX-B-6SR Series New Improved, Enhance & Extended capacity range of 192mm and 226mm compressor series Unique Patented Screw compressor technology High reliability and stability Excellent Performance And Operation Cost Efficiency AFVX-B-6SR Series Dunham-Bush patented screw profile design which is specially made for R134a application.. Carbon Steel screw profile with high precision machining.. Dynamic balancing and over speed testing before assembly to ensure the quality and stability.. AFVX-B-6SR Series Core components are all processed by sophisticated facilities Evaporator Improvement Flooded heat exchanger technology. Making use of unique “Skip-fin” Efficient Tube Design before Eliminator Refrigeration Vapor Tube Leaving Water Entering Water DB type (“skip-fin” design) Flow Equalizer Refrigeration Liquid Evaporator Improvement Suction baffle design (Eliminator) to eliminate or reduce the liquid carry over possibility. Provides uniform distribution of refrigerant over the entire shell length to yield optimum heat transfer . Flooded Evaporator • Higher capacity and Higher EER achievable with the same compressor − Good evaporator approach temperature < 3 F − Higher evaporating temperature compared to the DX evaporator system − Capacity increases from 724 RT to 796 RT ♦ 10% increase in capacity − Very little power increase Flooded Evaporator • Better Part‐Load Efficiency Flooded Evaporator Flooded Chiller Evaporator fully utilizes tube surface for heat transfer at part load DX Chiller Refrigerant in shell Water in tubes DX Evaporator Normally blank off part of the evaporator circuit Water in shell Portion of the tubes will not be used for heat Refrigerant in tubes transfer at part load Advance Controller Flexible programmable DDC advance Vision2020i controller. Complete with digital and analog I/O. Monitoring equipment or system status, water flow status, temperature, pressure, compressor amp, external start/ stop command status, and run time status. Embedded system protection controls. Low suction, high discharge, Freeze protection, compressor run error, compressor anti-cycle, compressor over current, compressor low oil and power lost…etc Remote Monitoring made possible with optional communication card(s) and NETVISOR software. Add on cards (options) are also available to allow direct interface to Building Management System (BMS) by means of standards open communication protocols (MODBUS / LONWORKS / BACNET MSTP or even Over IP) Chiller Monitoring & Control PC Remote PC Workstation Workstation Database Server Notebook PC Workstation Main equipment control and monitoring. Vary Flow rate of pump(s) by controlling system VFD. Temp difference monitoring and feedback. Chillers Primary CW Second. CW Pumps Pumps AHRI Certified Testing Facilities • Completed Units will be inspected by Quality Control Dept. • Every unit undergoes a functional and a full load performance test by the Chiller Testing Team before they are shipped out to end users. • Unit is shipped with refrigerant charged and Lubricating oil. Semi Hermetic and Fully Hermetic Comparison 07 HSC vs VSC Configuration.swf Semi Hermetic and Fully Hermetic Comparison - Structure • Double Layer Shell • All moving parts concealed within internal shell (Noise confined) Single Layer Shell • Hermetic Outer Shell – no leak, further noise reduction Semi Hermetic and Fully Hermetic Comparison - Rotor Superb wear & tear resistance Semi Hermetic and Fully Hermetic Comparison - Rotor Semi Hermetic and Fully Hermetic Comparison - Oil Separation Primary Oil Separator 2nd or Secondary Oil Separator Oil Deflector 99.7% Oil Separation 1st or Primary Oil Separator Semi Hermetic and Fully Hermetic Comparison - Bearing Lubrication Differential Pressure Lubrication Submerged in Oil – Always lubricated Semi Hermetic and Fully Hermetic Comparison - Capacity Control Precise Capacity Control with Hydraulically actuated electronically initiated stepless slide valve control Semi Hermetic and Fully Hermetic Comparison - Motor Cooling Ensure superheat on part load – maximize oil separation, minimize oil carry-over What’s Next..?? Air Cooled Screw Chiller with Inverter Driven (VFD)… Variable Frequency Drive Compressor Frequency range of 25-60Hz. IPLV improvement of 20-30% Environmentally Friendly R134A Low Noise and Compact Thank You Product That Perform … By People Who Care