E-Series Rooftop Units - US Air Conditioning Distributors Southern
Transcription
E-Series Rooftop Units - US Air Conditioning Distributors Southern
PA C KA G E D G A S E L E C T R I C LGH E-Series Rooftop Units 60 HZ P R O D U C T S P E C I F I C AT I O N S Bulletin No. LGH-242-360 (09/2012) ASHRAE 90.1 COMPLIANT 20 to 30 Tons Net Cooling Capacity - 238,000 to 354,000 Btuh Gas Input Heat Capacity - 260,000 to 480,000 Btuh MODEL NUMBER IDENTIFICATION L G H 300 H 4 B S 1 Y Voltage Y = 208/230V-3 phase-60hz G = 460V-3 phase-60hz J = 575V-3 phase-60hz Brand/Family L = E-Series Unit Type G = Packaged Gas Heat w/ Electric Cooling Major Design Sequence H = 1st Generation Nominal Cooling Capacity - Tons 242 = 20 Tons 300 = 25 Tons 360 = 30 Tons Cooling Efficiency H = High Efficiency Minor Design Sequence 1 = 1st Revision 2 = 2nd Revision 3 = 3rd Revision Heating Type S = Standard Gas Heat, 2 Stage M = Medium Gas Heat, 2 Stage H = High Gas Heat, 2 Stage Blower Type B = Constant Air Volume (CAV) Belt Drive V = Variable Air Volume (VAV) Belt Drive Refrigerant Type 4 = R-410A FEATURES AND BENEFITS H M O K G N D E L C J L E N N O X B F I E-Series packaged rooftop unit product line was created to save energy with intelligence by offering some of the highest energy efficiency ratings available with a powerful, easy to use unit controller. This makes E-Series rooftop units perfect for business owners looking for an HVAC product with the lowest total cost of ownership. E-Series rooftop units feature: • Hinged Access Panels - Provide quick access to components and protect panels and roof from damage during servicing. • Isolated Compressor Compartment - Allows performance check during normal compressor operation without disrupting airflow. • Corrosion-Resistant Removable Drain Pan - Provides improved serviceability. • Thermostatic Expansion Valves - Provide peak cooling performance across the entire application range. • Scroll Compressors - Standard on all units for reliable, long-term operation. • Eco-last™ Coil System - Smaller, lighter condenser coil. • Constant Air Volume (CAV) or Variable Air Volume (VAV) Blower Option - Allows constant or variable air delivery. • Auto-Tensioner for Blower Belt - Factory option ensures blower is delivering the proper airflow for comfort, while maximizing efficiency and belt life. • MERV 13 Filters - Available as factory or field option, provide an enhanced level of indoor air quality, and can help the building qualify for additional LEED credits. • Foil-Faced Insulation - Insulation on all internal surfaces that have contact with airflow helps minimize airborne fibers and improve IAQ. Intelli-guide™ Control System Standard on every E-Series rooftop unit, the new Intelli-guide™ unit controller is the heart of the Allied controls offering. The intuitive user interface makes setup, troubleshooting and service easier than ever. Each unit tracks the runtime of every major component and records the date and time when service or maintenance is performed. WireRight™ System The WireRight system simplifies field sensor or thermostat installation through advanced connectors that are keyed and color-coded to help prevent miswiring. Not only is the wire coloring scheme standardized across all models, each connection is intuitively labeled to make troubleshooting and servicing quick and easy. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 2 FEATURES AND BENEFITS Contents Accessory Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Blower Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Electrical Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Features And Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 High Altitude Derate . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Intelli-Guide™ Control System . . . . . . . . . . . . . . . . . . . . . . . .8 Model Number Identification . . . . . . . . . . . . . . . . . . . . . . . . .1 Options / Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Outdoor Sound Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Specifications - Gas Heat . . . . . . . . . . . . . . . . . . . . . . . . . 16 Unit Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Weight Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 APPROVALS 242 models are AHRI Certified to AHRI Standard 340/360-2007. 300 and 360 models are tested at conditions included in AHRI Standard 340/360-2007. ETL listed Units are certified by CSA International. Components bonded for grounding to meet safety standards for servicing required by UL, ULC and National and Canadian Electrical Codes.. All models are ASHRAE 90.1-2010 energy efficiency compliant and meet or exceed requirements of Section 6.8. ENERGY STAR® certified units are designed to use less energy, help save money on utility bills, and help protect the environment. ISO 9001 Registered Manufacturing Quality System. WARRANTY Limited ten years aluminized heat exchanger, limited fifteen years optional stainless steel heat exchanger. Limited five years on compressors. Limited three years on the Ecolast™ Coil System. HEATING SYSTEM B Aluminized steel inshot burners, direct spark ignition, electronic flame sensor, combustion air inducer, redundant automatic single or dual stage gas valve with manual shut-off. Heat Exchanger Tubular construction, aluminized steel, life cycle tested. Optional Stainless Steel Heat Exchanger is required if mixed air temperature is below 45°F. Electronic Pilot Ignition Electronic spark igniter provides positive direct ignition of burners on each operating cycle. The system permits main gas valve to stay open only when the burners are proven to be lit. Should a loss of flame occur, the gas valve closes, shutting off the gas to the burners. Ignition module has LED to indicate status and aid in troubleshooting. Ignition control is factory installed in the controls section. Limit Controls Factory installed, redundant limit controls with fixed temperature setting. Heat limit controls protect heat exchanger and other components from overheating. Safety Switches Flame roll-out switch, flame sensor and combustion air inducer proving switch protect system operation. REQUIRED SELECTIONS Limited three years on Intelli-guide™ Unit Controller. Gas Input Choice - Order one: Standard Gas Heat, 2 Stage (169,000/260,000 Btuh) Limited one year all other covered components. Medium Gas Heat, 2 Stage (234,000/360,000 Btuh) High Gas Heat, 2 Stage (312,000/480,000 Btuh) E-Series Packaged Gas / Electric 20 to 30 Ton / Page 3 FEATURES AND BENEFITS HEATING SYSTEM (CONTINUED) OPTIONS/ACCESSORIES Factory Installed Stainless Steel Heat Exchanger Required if mixed air temperature is below 45°F. Factory or Field Installed Low Temperature Vestibule Heater Electric heater automatically controls minimum temperature in gas burner compartment when temperature is below -40°F. CSA certified to allow operation of unit down to -60°F. Field Installed Combustion Air Intake Extensions Recommended for use with existing flue extension kits in areas where high snow areas can block intake air. Order two kits. LPG/Propane Kits Conversion kit to field change over units from Natural Gas to LPG/ Propane. Order two kits. Vertical Vent Extension Kit Use to exhaust flue gases vertically above unit. Required when unit vent is too close to fresh air intakes per building codes. The vent kit also prevents ice formation on intake louvers. Order two kits. Kit contains vent transition, vent tee, drain cap and installation hardware. NOTE - Straight vent pipes (4 in. B-Vent) and caps are not furnished and must be field supplied. Refer to kit instructions for additional information. COOLING SYSTEM Designed to maximize sensible and latent cooling performance at design conditions. System can operate from 0°F to 125°F without any additional controls. R-410A Refrigerant Non-chlorine based, ozone friendly, R-410A. C Scroll Compressors Scroll compressors on all models for high performance, reliability and quiet operation. Resiliently mounted on rubber grommets for quiet operation. Compressor Crankcase Heaters Protects against refrigerant migration that can occur during low ambient operation. D Thermal Expansion Valves Assures optimal performance throughout the application range. Removable element head. E Filter/Driers High capacity filter/drier protects the system from dirt and moisture. High Pressure Switches Protects the compressors from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation. Automatic reset. Low Pressure Switches Protects the compressors from low pressure conditions such as low refrigerant charge, or low/no airflow. Freezestats Protects the evaporator coil from damaging ice build-up due to conditions such as low/no airflow, or low refrigerant charge. F Eco-last™ Coil System Condenser coil features lightweight, all aluminum brazed fin construction. Constructed of three components: a flat extrusion tube, fins inbetween the flat extrusion tube and two refrigerant manifolds. Eco-last™ System Features: • I mproved heat transfer performance due to high primary surface area (flat tubes) versus secondary surface (fins). • S maller internal volume (reduced refrigerant charge). • H igh durability (all aluminum construction). • Fewer brazed joints. • C ompact design (reduces unit weight). • Easy maintenance/cleaning. Face split design. Mounting brackets with rubber inserts secure coil to unit providing vibration dampening and corrosion protection. Angled design in cabinet helps protect coil from possible contact or hail damage. Evaporator Coil Copper tube construction, enhanced rippled-edge aluminum fins, flared shoulder tubing connections, silver soldered construction for improved heat transfer. Factory leak tested. Cross row circuiting with rifled tubing optimizes both sensible and latent cooling capacity. Low fin per inch count minimizes air pressure drop. Constant air volume (CAV) models have face-split evaporator coils. Variable air volume (VAV) models have row-split evaporator coils designed to keep condensate water off of an inactive part of the coil so the condensate will not reenter the air stream. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 4 FEATURES AND BENEFITS COOLING SYSTEM (CONTINUED) Condensate Drain Pan Plastic pan, sloped to meet drainage requirements of ASHRAE 62.1. Side drain connections. Stainless steel drain pan available as a factory installed option. G Outdoor Coil Fan Motors Thermal overload protected, totally enclosed, permanently lubricated ball bearings, shaft up, wire basket mount. Outdoor Coil Fans PVC coated fan guard furnished. REQUIRED SELECTIONS Cooling Capacity Specify nominal cooling capacity of the unit OPTIONS/ACCESSORIES Factory Installed Discharge Air Temperature Sensor Sensor sends information to the unit controller to cycle up to 2 stages of heating or 4 stages of cooling to maintain the discharge air setpoints for heating or cooling. Optional for CAV units (single zone or bypass zoning control). Automatically furnished with all Variable Air Volume (VAV) units. Sensor is shipped with the unit for remote field installation in the supply duct. OPTIONS/ACCESSORIES Factory or Field Installed Condensate Drain Trap Field installed only, may be factory enclosed to ship with unit. Available in copper or PVC. Drain Pan Overflow Switch Monitors condensate level in drain pan, shuts down unit if drain becomes clogged. Stainless Steel Drain Pan Non-corrosive drain pan. CABINET OPTIONS/ACCESSORIES Factory Installed H Construction Heavy-gauge steel panels and full perimeter heavy-gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation. Base rails have rigging holes. Three sides of the base rail have forklift slots. Raised edges around duct and power entry openings in the bottom of the unit provide additional protection against water entering the building. Airflow Choice Units are available in downflow (vertical) or horizontal return air flow configuration. Horizontal air flow requires Horizontal Roof Curb. Horizontal Return Air Panel Kit is also required if converting a downflow configured unit to horizontal air flow. Power/Gas Entry Electrical and gas lines can be brought through the unit base or through horizontal access knockouts Exterior Panels Constructed of heavy-gauge, galvanized steel with a two-layer enamel paint finish. Insulation All panels adjacent to conditioned air are fully insulated with nonhygroscopic fiberglass insulation. Unit base is fully insulated. The insulation also serves as an air seal to the roof curb, eliminating the need to add a seal during installation. Corrosion Protection A completely flexible immersed coating with an electrodeposited dry film process. (AST ElectroFin E-Coat) Meets Mil Spec MIL-P-53084, ASTM B117 Standard Method Salt Spray Testing. Indoor Corrosion Protection: - Coated coil - Painted blower housing - Painted indoor base Outdoor Corrosion Protection: - Coated coil - Painted outdoor base Field Installed Coil Guards Painted, galvanized steel wire guards to protect outdoor coil. Not used with Hail Guards. Grille Guards Protects the space between outdoor coils and main cabinet. Hail Guards Constructed of heavy gauge steel, painted to match cabinet, helps protect outdoor coils from hail damage. Not used with Coil Guards. Horizontal Return Air Panel Kit Required for horizontal applications with Horizontal Roof Curb, contains panel with return air opening for field replacement of existing unit panel and panel to cover bottom return air opening in unit, see dimension drawings. I Hinged Access Panels Hinged tool-less access panels are provided for the filter section, the blower section and compressor/ controls section. All hinged panels have seals and quarter-turn latching handles to provide a tight air and water seal. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 5 FEATURES AND BENEFITS J BLOWER A wide selection of supply air blower options are available to meet a variety of airflow requirements. Motor Overload protected, equipped with ball bearings. Belt drive motors are offered on all models and are available in several different sizes to maximize air performance. Motor Efficiency All blower motors 5 hp and above meet minimum energy efficiency standards in accordance with the Energy Independence and Security Act (EISA).of 2007. Supply Air Blower Forward curved blades, double inlet, blower wheel is statically and dynamically balanced. Belt drive motors with adjustable pulley for speed change on CAV units.. OPTIONS/ACCESSORIES Factory Installed Blower Belt Auto-Tensioner Provides proper tension to belt drive blower belt without the need for regular adjustments. Maintains airflow and proper performance. Supply Static Transducer Transducer sends information to the Intelli-guide™ Unit Controller to control VFD blower speed. Automatically furnished with all VAV units. Transducer is shipped with the unit for remote field installation in the supply duct. Manual Supply VFD Blower Bypass Control Allows variable air volume (VAV) unit to operate as a constant air volume (CAV) unit in case of variable frequency drive (VFD) failure. Blower assembly slides out of unit for servicing. NOTE - Bypass control is a manual operation. All supply air duct registers must be opened manually. Grease fittings furnished. Field Installed REQUIRED SELECTIONS Supply Static Limit Switch Field installed manual reset switch for supply static high pressure limit. Prevents exceeding pressure limit in supply air duct. Optional Mounting Kit includes tubing and adaptors. Supply Air Blower Specify Constant Air Volume (CAV) or Variable Air Volume (VAV). Order Standard or High Efficiency Blower motor (See Blower Data Table for specifications). NOTE - 575V VAV models are only available with high efficiency blower motors. Order one drive kit, see Drive Kit Specifications Table. ELECTRICAL REQUIRED SELECTIONS Voltage Choice Specify when ordering base unit. Circuit Breakers HACR type. For overload and short circuit protection. Factory wired and mounted in the power entry panel. Current sensitive and temperature activated. Manual reset. OPTIONS/ACCESSORIES Factory Installed Circuit Breakers HACR type. For overload and short circuit protection. Factory wired and mounted in the power entry panel. Current sensitive and temperature activated. Manual reset. Phase/Voltage Detection Phase detection monitors power supply to assure phase is correct at unit start-up. If phase is incorrect, the unit will not start and an alarm code is reported to the unit controller. Protects unit from being started with incorrect phasing which could lead to issues such as compressors running backwards. Voltage detection monitors power supply voltage to assure proper voltage. If voltage is not correct (over/under voltage conditions) the unit will not start and an alarm code is reported to the unit controller. Factory or Field Installed Disconnect Switch Accessible from outside of unit, spring loaded weatherproof cover furnished. GFI Service Outlets (2) 115V ground fault circuit interrupter (GFCI) type, non-powered, field-wired or factory-wired and powered. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 6 FEATURES AND BENEFITS INDOOR AIR QUALITY K Air Filters Disposable 2 inch filters furnished as standard. OPTIONS/ACCESSORIES Factory Installed UVC Germicidal Light Kit Germicidal lamps emit ultra-violet (UV-C) energy, which has been proven to be effective in reducing microbes such as viruses, bacteria, yeasts, and molds. This process either destroys the organism or controls its ability to reproduce. UV-C energy greatly reduces the growth and proliferation of mold and other bioaerosols (bacteria and viruses) on illuminated surfaces (particularly coil and drain pan). Lamps are field installed in the blower/evaporator coil section. All necessary hardware for installation is included. Lamps operate on 110/230V, single phase power supply. Step-down transformer is furnished with lamps when used with 460V and 575V rooftop units. Approved by ETL. Factory or Field Installed High Efficiency Air Filters Disposable MERV 8 or MERV 13 (Minimum Efficiency Reporting Value based on ASHRAE 52.2) efficiency 2 inch pleated filters. Blower Access Supply air blower parts are located near the access door for easy servicing and adjustment. Blower assembly slides out of unit for servicing. Replacement Filter Media Kit With Frame Replaces existing pleated filter media. Includes washable metal mesh screen and metal frame with clip for holding replaceable nonpleated filter. Thermal Expansion Valves Thermal expansion valves are located near the perimeter of the unit for easier access. Field Installed Coil Cleaning Slab condenser coils provided for easier cleaning. Indoor Air Quality (CO2) Sensors Monitors CO2 levels, reports to the Intelli-guide™ Unit Controller which adjusts economizer dampers as needed. SERVICEABILITY Designed to streamline general maintenance and decrease troubleshooting time. Diagnostics Intelli-guide™ Unit Controller diagnostic scrolling text pinpoints problems, minimizing troubleshooting time. WireRight™ System Advanced wiring connectors are keyed and color-coded to prevent miswiring. Wire coloring scheme is standardized across all models. Each connection is intuitively labeled to make troubleshooting and servicing quick and easy. Removable element head allows change out of element and bulb without removing the TXV. Standard Components A large number of common maintenance parts are standard throughout the entire range of sizes (3-30 tons), reducing the need to carry a lot of different parts to the job or maintain in inventory. Compressor Compartment Compressors are located near the perimeter of the unit for easier access. Compressors are isolated from the condenser airflow allowing system operation checks to be done without changing the airflow across the outdoor coils. Electrical Plugs Positive connection electrical plugs are used to connect common accessories or maintenance parts for easy removal or installation. Toolless, Hinged Access Panels Large access panels are hinged and have quarter-turn, latching handles for quick and easy access to maintenance areas (filter, compressor / controls/ blower / heat section). E-Series Packaged Gas / Electric 20 to 30 Ton / Page 7 INTELLI-GUIDE™ CONTROL SYSTEM L INTELLI-GUIDE CONTROLLER The Intelli-guide Unit Controller is a microprocessor-based control board that provides flexible control of all unit functions. Intelli-guide™ Features: Scrolling Display - Scrolls full text instead of numerical codes. Push Buttons - Simplified navigation during setup and diagnostics. Guided Setup Procedure Insures proper installation and setup of the rooftop unit. Profile setup - Copy key setpoints between units with the same configuration greatly reducing setup time. USB Port - Easily download and transfer unit information via a USB flash drive and also interface with Allied Unit Controller Software. Self Test Mode - Confirm proper component and system operation. Time Clock with Run-time Information Built-In Functions Include: Adjustable Blower On/Off Delay Blower Air Delivery Options Built-in Control Parameter Defaults Compressor Time-Off Delay DDC Compatible Dirty Filter Switch Input Discharge Air Temperature Control Display/Sensor Readout Economizer Control Options See Economizer / Outdoor Air / Exhaust Options. Fresh Air Tempering Extensive Unit Diagnostics Over 100 diagnostic and status messages in English. Exhaust Fan Control Modes Fresh air damper position. Permanent Diagnostic Code Storage Field Changeable Control Setpoints - Over 200 different control setpoints. Indoor Air Quality Input Demand Control Ventilation ready Low Ambient Controls - Cooling operation down to 0°F. Gas Valve Time Delay Between First and Second Stage Minimum Compressor Run Time Network Capable - Can be daisy chained to other units or controls. Night Setback Mode Return Air Temperature Limit Control Safety Switch Input - Allows Controller to respond to a external safety switch trip. Service Relay Output Smoke Alarm Mode - Four choices. Staging - up to 2 heat / 2 cool with standard Intelli-guide unit controller. Up to 2 heat / 4 cool with add-on control board. “Strike Three” Protection Gas Reheat Control Simultaneous heating and cooling operation for controlling humidity for process air applications such as supermarkets. Thermostat Bounce Delay Warm Up Mode Delay LED Indicators PC Interface - For use with PC with optional Unit Controller software. VAV Control Zone Sensor Operation - Controls zone temperature. CONTROLS OPTIONS Factory or Field Installed OPTIONS / ACCESSORIES Factory or Field Installed Humidity Sensor Kit Humidity sensor required with Supermarket reheat field selectable option. Blower Proving Switch Monitors blower operation, shuts down unit if blower fails. Dirty Filter Switch Senses static pressure increase indicating dirty filter condition. NOTE - Intelli-guide Control System features shown vary with the type of rooftop unit the control is installed in. NOTE - See separate Intelli-guide Control System Product Specifications Bulletin for additional information. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 8 Fresh Air Tempering Used in applications with high outside air requirements. The Controller energizes the first stage heat as needed to maintain a minimum supply air temperature for comfort, regardless of the thermostat demand. When ordered as a factory option, the sensor ships with the unit but must be field installed. Smoke Detector Photoelectric type, installed in supply air section, return air section or both sections. Available with power board and single sensor (supply or return) or power board and two sensors (supply and return). Power board located in unit control compartment. Interoperability via BACnet® or LonTalk® Protocols Communication compatible with third-party automation systems that support the BACnet Application Specific Controller device profile, LonMark® Space Comfort Controller functional profile, or LonMark Discharge Air Controller functional profile. Commercial Control Systems Aftermarket DDC Novar® Unit Controller and options. Thermostats Control system and thermostat options. Aftermarket unit controller options. Field Installed OPTIONS / ACCESSORIES N ECONOMIZER/EXHAUST OPTIONS Factory or Field Installed Economizer - Downflow or Horizontal With Air Hood Parallel gear-driven action return air and outdoor air dampers, plug-in connections to unit, nylon bearings, neoprene seals, 24volt, fully-modulating, spring return motor, adjustable minimum damper position. Outdoor air hoods for economizer and downflow barometric relief dampers furnished. Choice of economizer control options: 1. Differential Sensible Control Factory setting. Uses outdoor air and return air sensors that are furnished with the unit. The Intelli-guide™ Unit Controller compares outdoor air and return air and using setpoints, enables the economizer when the outdoor air temperature is below the configured setpoint and cooler than return air. NOTE - Differential Sensible Control can be configured in the field to provide Offset Differential Sensible Control or Single Sensible Control. In Offset Differential Sensible Control mode, the economizer is enabled if the temperature differential (offset) between outdoor air and return air reaches the configured setpoint. In Single Sensible Control mode, the economizer is enabled when outdoor air temperature falls below the configured setpoint. 2. Global Control The unit controller communicates with a DDC system with one global sensor (enthalpy or sensible) to determine whether outside air is suitable for free cooling on all units connected to the control system. Sensor must be field provided. 3. Single Enthalpy Control Outdoor air enthalpy sensor enables economizer if the outdoor enthalpy is less than the setpoint of the board. 4. Differential Enthalpy Control Two solid-state enthalpy sensors allow the economizer control to select between outdoor air or return air, whichever has lower enthalpy. Outdoor Air CFM Control Maintains constant outdoor air CFM levels for VAV units with variable frequency drives on the supply fan and varying unit airflows. Using information from a velocity sensor located in the units’ outdoor air section, the Intelliguide™ Unit Controller changes the economizer position to help minimize the effect of supply fan speed changes on outdoor air CFM levels. Setpoint for outdoor air CFM is established by field testing. NOTE - Not available with Demand Control Ventilation (CO2 Sensor). Downflow Barometric Relief Dampers O Allow relief of excess air, aluminum blade dampers prevent blow back and outdoor air infiltration during off cycle, bird screen furnished. Hood for downflow barometric relief dampers is factory installed when dampers are factory installed with economizer. Hood is furnished with dampers when ordered for field installation. P Standard Static Power Exhaust Fans Three, 1/3 hp motors with 20 in., five blade propeller-type fans with a total power input of 1125 Watts and a total air volume of 12,800 cfm at 0 in. w.g. Motor is inherently protected and enclosed for maximum protection from weather, dust and corrosion. Installs internal to unit for downflow applications only with economizer option, provides exhaust air pressure relief, interlocked to run when return air dampers are closed and supply air blower is operating, fan runs when outdoor air dampers are 50% open (adjustable), motor is overload protected, steel cabinet and hood painted to match unit, requires optional Downflow Economizer Barometric Relief Dampers. See Standard Static Power Exhaust Blower Tables. High Static Power Exhaust Fans Choice of 50% (two, 2 hp motors) or 100% (three, 2 hp motors) centrifugal-type power exhaust. Overload and sub-fuse protected, equipped with ball bearings. Forward curved blades, blower wheel is statically and dynamically balanced. Constant volume high static power exhaust fans have adjustable pulleys for speed adjustments and are controlled by damper position. Variable air volume units (with variable frequency drive) have 100% capacity and can be ordered with an optional VFD bypass. Fans feature solid-state analog pressure transducer control which senses differential pressure between conditioned space and outdoor air to regulate fan speed. See High Static Power Exhaust Blower Tables. NOTE - High Static Power Exhaust is field installed but must be ordered at the same time as the rooftop unit so the unit can be factory configured for this option. Power Exhaust Control Options: Damper Position Control Intelli-guide™ Unit Controller controls exhaust fan based on economizer damper position. For Standard or High Static Power Exhaust (without VFD) Fans only. Differential Pressure Transducer Differential pressure transducer compares atmospheric pressure to conditioned space static pressure for controlling exhaust fan. Transducer is factory installed in the power exhaust section. For High Static Power Exhaust (with VFD) fans only. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 9 FEATURES AND BENEFITS ECONOMIZER/EXHAUST OPTIONS (CONTINUED) Field Installed Horizontal Barometric Relief Dampers For use when unit is configured for horizontal applications requiring an economizer. Allows relief of excess air. Aluminum blade dampers prevent blow back and outdoor air infiltration during off cycle. Field installed in return air duct. Bird screen and hood furnished. OUTDOOR AIR OPTIONS Factory or Field Installed Outdoor Air Damper Downflow or Horizontal With Air Hood Linked mechanical dampers, 0 to 25% (fixed) outdoor air adjustable, installs in unit. Includes outdoor air hood. Automatic model features fully modulating spring return damper motor with plug-in connection. Manual model features parallel blade, gear-driven dampers with adjustable fixed position. ROOF CURBS Nailer strip furnished, mates to unit, US National Roofing Contractors Approved, shipped knocked down. Downflow Clip Curbs (Full Perimeter) Uses interlocking tabs to fasten corners together. No tools required. Available in 14 inch, 18 inch and 24 inch heights. Standard Curbs - Curb corners fasten together with furnished hardware. Full perimeter curbs are also available. Available in 14 inch and 24 inch heights Horizontal Converts unit from downflow to horizontal (side) air flow, return air is on unit, supply air is on curb, see dimension drawings. Requires Horizontal Return Air Panel Kit. Available in 37 inch and 41 inch heights. Optional Insulation Kit is available to help prevent sweating. Minimum mixed air temperature in heating mode is 30°F. Maximum mixed air temperature in cooling mode is 90°F. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 10 CEILING DIFFUSERS Ceiling Diffusers (Flush or Step-Down) Aluminum grilles, large center grille, insulated diffuser box with flanges, hanging rings furnished, interior transition (even air flow), internally sealed (prevents recirculation), adapts to T-bar ceiling grids or plaster ceilings. Transitions (Supply and Return) Used with diffusers, installs in roof curb, galvanized steel construction, flanges furnished for duct connection to diffusers, fully insulated. OPTIONS / ACCESSORIES Model Number Unit Model No. Catalog Number 242 300 360 PVC - C1TRAP20AD2 76M26 OX OX OX Copper - C1TRAP10AD2 76W27 OX OX OX Factory O O O E1SNSR71AD1 68W88 OX OX OX High Factory O O O R-410A Factory O O O Item Description COOLING SYSTEM Condensate Drain Trap Corrosion Protection Drain Pan Overflow Switch Efficiency Refrigerant Type Plastic Condensate Drain Pan Stainless Steel Condensate Drain Pan C1DPAN10D-1- Factory O O O 84W76 OX OX OX GAS HEAT Combustion Air Intake Extensions (Order 2 Kits) Gas Heat Input LPG/Propane Conversion Kits (Order 2 Kits) Low Temperature Vesibule Heater C1EXTN10FF1 89L97 X X X Standard - 260 kBtuh input Factory O O O Medium - 360 kBtuh input Factory O O O High - 480 kBtuh input Factory O O O Standard Heat - LTALPGK-130 72M94 X X X Medium Heat - LTALPGK-180 72M95 X X X High Heat - LTALPGK-240 72M96 X X X 208/230V-3ph - C1LTVH10C-1Y 58W28 OX OX OX 460V-3ph - C1LTVH10C-1G 58W29 OX OX OX 575V-3ph - C1LTVH10C-1J 58W30 OX OX OX Factory O O O C1EXTN20FF1 42W16 X X X Belt Drive (standard efficiency) - 5 hp Factory O O O Stainless Steel Heat Exchanger Vertical Vent Extension BLOWER - SUPPLY AIR Motors Belt Drive (standard efficiency) - 7.5 hp Factory O O O Belt Drive (standard efficiency) - 10 hp Factory O O O Manual Supply VFD Blower Bypass (VAV units w/VFD only) Factory O O O Drive Kits See Blower Data Tables for usage and selection Kit #1 740-895 rpm Factory O O O Kit #2 870-1045 rpm Factory O O O Kit #3 715-880 rpm Factory O O O Kit #4 770-965 rpm Factory O O O Kit #5 660-810 rpm Factory O O O Kit #6 770-965 rpm Factory O O O Kit #7 570-720 rpm Factory O O O Kit #8 480-630 rpm Factory O O O Kit #9 410-535 rpm Factory O O O Blower Belt Auto-Tensioner Factory O O O CABINET Coil Guards Grille Guards Hail Guards Horizontal Return Air Panel Kit C1GARD29D-1 84W63 X X X C1GARD39D-1- 86K30 X X X C1GARD19D-1 84W62 X X X 38K48 X X X NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Field Installed O = Configure To Order (Factory Installed) X = Field Installed E-Series Packaged Gas / Electric 20 to 30 Ton / Page 11 OPTIONS / ACCESSORIES 242 300 360 C1SNSR35FF1 53W65 OX OX OX Intelli-guide™ System - BACnet® Module - C0CTRL60AE1L Intelli-guide™ System - LonTalk® Module - C0CTRL65FF1 Novar® ETM-2051 Unit Controller - E0CTRL30C1 Novar® LSE Dirty Filter Switch E1SNSR55C-1 Discharge Air Temperature Sensor Fresh Air Tempering C1SNSR75AD1 Smoke Detector - Supply or Return (Power board and one sensor) C1SNSR44C-1 Smoke Detector - Supply and Return (Power board and two sensors) C1SNSR43C-1 Supply Static Limit Switch C0SNSR11AE1 Supply Static Limit Switch - Mounting Kit C0SNSR12AE1 Supply Static Transducer C0SNSR20AE1 INDOOR AIR QUALITY Air Filters High Efficiency Air Filters MERV 8 - C1FLTR15D-120 x 20 x 2 - order 12 per unit MERV 13 - C1FLTR40D-1Replaceable Media Filter with Metal Mesh Frame (includes NonC1FLTR30D-1Pleated Filter Media) 20 x 20 x 2- order 12 per unit Indoor Air Quality (CO2) Sensors Sensor - Wall-mount, off-white plastic cover with LCD display C0SNSR50AE1L Sensor - Wall-mount, off-white plastic cover, no display C0SNSR52AE1L C0SNSR51AE1L Sensor - Black plastic case with LCD display, rated for plenum mounting Sensor - Wall-mount, black plastic case, no display, rated for plenum C0MISC19AE1 mounting C0MISC19AE1CO2 Sensor Duct Mounting Kit - for downflow applications C0MISC16AE1Aspiration Box - for duct mounting non-plenum rated CO2 sensors (87N53 or 77N39) UVC Germicidal Light Kit 1 UVC Light Kit (110/230v-1ph) C1UVCL10C-1 ELECTRICAL Voltage 60 hz 208/230V - 3 phase 460V - 3 phase 575V - 3 phase Disconnect Switch - See Electrical 80 amp Accessories Tables on page 31 for selection 150 amp 250 amp GFI Service 15 amp non-powered, field-wired (208/230V, 460V only) LTAGFIK10/15 Outlets 15 amp factory-wired and powered (208/230V, 460V only) 20 amp non-powered, field-wired (575V only) Phase/Voltage Detection ECONOMIZER Economizer Economizer - (Hood Furnished) E1ECON15D-1 Economizer Controls Differential Enthalpy Order 2 - C1SNSR64FF1 Sensible Control Sensor is Furnished Single Enthalpy C1SNSR64FF1 Global, Enthalpy Sensor Field Provided Sensor is Furnished Differential Sensible Outdoor Air CFM Control Barometric Relief Downflow Barometric Relief Dampers - (Hood Furnished) E1DAMP60D-1 Horizontal Barometric Relief Dampers - (Hood Furnished) LAGEDH30/36 59W51 54W27 64W74 Factory 53W68 Factory 58W63 83W40 83W41 79M80 79M81 78M19 OX OX OX O OX O OX OX OX X X X OX OX OX O OX O OX OX OX X X X OX OX OX O OX O OX OX OX X X X 54W21 52W39 44N60 OX OX X OX OX X OX OX X 77N39 87N53 87N52 87N54 X X X X X X X X X X X X 85L43 90N43 X X X X X X Factory O O O Factory Factory Factory 54W88 54W89 90W82 74M70 Factory Factory Factory O O O OX OX OX OX O O O O O O OX OX OX OX O O O O O O OX OX OX OX O O O 74W43 OX OX OX 53W64 Factory 53W64 Factory Factory Factory OX O OX O O O OX O OX O O O OX O OX O O O 76W17 33K78 OX OX OX OX OX OX CONTROLS Blower Proving Switch 1 Model Number Unit Model No. Catalog Number Item Description Lamps operate on 110/230V, single phase power supply. Step-down transformer is furnished with lamps when used with 460V and 575V rooftop units. NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Field Installed O = Configure To Order (Factory Installed) X = Field Installed E-Series Packaged Gas / Electric 20 to 30 Ton / Page 12 OPTIONS / ACCESSORIES Model Number Item Description Catalog Number Unit Model No. 242 300 360 OUTDOOR AIR Outdoor Air Dampers - Motorized - (Hood Furnished) E1DAMP25D-1- 74W44 OX OX OX Outdoor Air Dampers - Manual - (Hood Furnished) E1DAMO15D-1- 74W45 OX OX OX 208/230V - E1PWRE40D-1Y 74W21 OX OX OX 460V - E1PWRE40D-1G 74W22 OX OX OX 575V - E1PWRE40D-1J 74W23 OX OX OX POWER EXHAUST Standard Static High Static - 50% High Static - 100% 100% with VFD 100% with VFD and Bypass 208/230V - Drive Kit #1 (405-533 rpm) - LAPEB30/36AY 83M83 X X X 208/230V - Drive Kit #2 (531-731 rpm) - LAPEB30/36BY 84M34 X X X 208/230V - Drive Kit #3 (731-932 rpm) - LAPEB30/36CY 84M35 X X X 460V - Drive Kit #1 (405-533 rpm) - LAPEB30/36AG 83M84 X X X 460V - Drive Kit #2 (531-731 rpm) - LAPEB30/36BG 84M36 X X X 460V - Drive Kit #3 (731-932 rpm) - LAPEB30/36CG 84M37 X X X 575V - Drive Kit #1 (405-533 rpm) - LAPEB30/36AJ 83M85 X X X 575V - Drive Kit #2 (531-731 rpm) - LAPEB30/36BJ 84M38 X X X 575V - Drive Kit #3 (731-932 rpm) - LAPEB30/36CJ 84M39 X X X 208/230V - Drive Kit #1 (406-533 rpm) - LAPEB30/36DY 83M86 X X X 208/230V - Drive Kit #2 (531-731 rpm) - LAPEB30/36EY 84M40 X X X 208/230V - Drive Kit #3 (731-932 rpm) - LAPEB30/36FY 84M41 X X X 460V - Drive Kit #1 (406-533 rpm) - LAPEB30/36DG 83M87 X X X 460V - Drive Kit #2 (531-731 rpm) - LAPEB30/36EG 84M42 X X X 460V - Drive Kit #3 (731-932 rpm) - LAPEB30/36FG 84M43 X X X 575V - Drive Kit #1 (406-533 rpm) - LAPEB30/36DJ 83M88 X X X 575V - Drive Kit #2 (531-731 rpm) - LAPEB30/36EJ 84M44 X X X 575V - Drive Kit #3 (731-932 rpm) - LAPEB30/36FJ 84M45 X X X 208/230V - LAPEV30/36GY 83M89 X X X 460V - LAPEV30/36GG 83M90 X X X 575V - LAPEV30/36GJ 83M91 X X X 208/230V - LAPEV30/36HY 83M92 X X X 460V - LAPEV30/36HG 83M93 X X X 575V - LAPEV30/36HJ 83M94 X X X NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Field Installed O = Configure To Order (Factory Installed) X = Field Installed E-Series Packaged Gas / Electric 20 to 30 Ton / Page 13 OPTIONS / ACCESSORIES Model Number Item Description Unit Model No. Catalog Number 242 300 360 ROOF CURBS - DOWNFLOW Clip Curbs 14 in. height LARMF30/36S-14 54K58 X X 18 in. height LARMF30/36S-18 54K59 X X 24 in. height LARMF30/36S-24 Standard Curbs 14 in. height LARMF18/36-14 24 in. height LARMF18/36-24 Standard Curbs - Full Perimeter 14 in. height S6CURB1012124 in. height S6CURB11121ROOF CURBS - HORIZONTAL (REQUIRES (HORIZONTAL AIR PANEL KIT) Standard Curbs 30 in. height - slab applications LARMFH30/36-30 41 in. height - rooftop applications LARMFH30/36-41 Clip Curbs 30 in. height - slab applications LARMFH30/36S-30 (Canada Only) 41 in. height - rooftop applications LARMFH30/36S-41 (Canada Only) Horizontal Return Air Panel Kit (Required) 54K60 X X X 16K87 16K88 X X X X X X 30W15 30W16 X X X X X X 33K79 38K54 X X X X X X 45K71 45K72 38K48 X X X X X X X X X for LARMFH30/36-30 73K33 X X X for LARMFH30/36-41 73K35 X X X Insulation Kit For Standard Horizontal Curbs CEILING DIFFUSERS Step-Down - Order one LARTD30/36 35K25 X X X LARTD30/36S (Canada Only) 45K74 X X X LAFD30/36 35K24 X X X LAFD30/36S (Canada Only) 45K75 X X X LASRT30/36 33K80 X X X Flush - Order one Transitions (Supply and Return) - Order one NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Field Installed O = Configure To Order (Factory Installed) X = Field Installed E-Series Packaged Gas / Electric 20 to 30 Ton / Page 14 SPECIFICATIONS General Data Nominal Tonnage Model Number Efficiency Type Blower Type 20 Ton LGH242H4V High Variable Air Volume VAV 244,000 238,000 6800 19.3 12.3 15.5 R-410A 8 lbs. 0 oz. 8 lbs. 0 oz. 8 lbs. 8 oz. 8 lbs. 8 oz. 25 Ton LGH300H4B High Constant Air Volume CAV 310,000 300,000 8100 25.9 11.6 12.5 R-410A 9 lbs. 4 oz. 9 lbs. 0 oz. 9 lbs. 0 oz. 9 lbs. 0 oz. 25 Ton 30 Ton 30 Ton LGH300H4V LGH360H4B LGH360H4V High High High Variable Air Constant Air Variable Air Volume VAV Volume CAV Volume VAV 310,000 370,000 370,000 300,000 354,000 354,000 8100 9600 9600 25.4 33.4 33.4 11.6 10.6 10.6 14.3 11.5 13.5 R-410A R-410A R-410A 8 lbs. 0 oz. 9 lbs. 0 oz. 8 lbs. 0 oz. 8 lbs. 0 oz. 8 lbs. 0 oz. 8 lbs. 0 oz. 8 lbs. 0 oz. 9 lbs. 0 oz. 8 lbs. 0 oz. 8 lbs. 8 oz. 7 lbs. 8 oz. 8 lbs. 0 oz. See page 16 Scroll (4) Scroll (4) Scroll (4) Scroll (4) 68.3 68.3 68.3 68.3 1 1 1 1 23 23 23 23 (6) 1/3 (6) 1/3 (6) 1/3 (6) 1/3 1075 1075 1075 1075 2500 2500 2500 2500 (6) 24 (6) 24 (6) 24 (6) 24 3 3 3 3 21,500 21,500 21,500 21,500 31.40 31.40 31.40 31.40 3/8 3/8 3/8 3/8 4 4 4 4 14 14 14 14 (1) 1 in. NPT (1) 1 in. NPT (1) 1 in. NPT (1) 1 in. NPT Balance port TXV, removable head 5 hp, 7.5 hp, 10 hp 5 hp, 7.5 hp, 10 hp Gross Cooling Capacity - Btuh 1 Net Cooling Capacity - Btuh AHRI Rated Air Flow - cfm Total Unit Power - kW 1 EER (Btuh/Watt) 2 IEER (Btuh/Watt) Refrigerant Type Refrigerant Circuit 1 Charge Circuit 2 Circuit 3 Circuit 4 Gas Heating Options Available Compressor Type (number) Scroll (4) Outdoor Net face area (total) - sq. ft. 68.3 Coils Number of rows 1 23 Fins per inch Outdoor Coil Motor - (No.) horsepower (6) 1/3 Fans Motor rpm 1075 Total Motor watts 2500 Diameter - (No.) in. (6) 24 Number of blades 3 Total Air volume - cfm 21,500 Indoor Coils Net face area (total) - sq. ft. 31.40 Tube diameter - in. 3/8 Number of rows 4 Fins per inch 14 Drain connection - No. and size (1) 1 in. NPT Expansion device type 3 Indoor Nominal motor output 5 hp, 7.5 hp, 10 Blower hp and Maximum usable motor output 5.75 hp, 5.75 hp, 8.63 hp, 11.5 hp 5.75 hp, 8.63 hp, 11.5 hp Kit (US Only) 8.63 hp, 11.5 hp Selection 5 hp 5 hp Motor - Kit kit number 5 hp Kit 5 660-810 rpm Kit 5 660-810 rpm Kit 5 660-810 rpm Kit 6 770-965 rpm Kit 6 770-965 rpm Kit 6 770-965 rpm Kit 7 570-720 rpm Kit 7 570-720 rpm Kit 7 570-720 rpm Kit 8 480-630 rpm Kit 8 480-630 rpm Kit 8 480-630 rpm Kit 9 410-535 rpm Kit 9 410-535 rpm Kit 9 410-535 rpm 7.5 hp 7.5 hp 7.5 hp Kit 3 715-880 rpm Kit 3 715-880 rpm Kit 3 715-880 rpm Kit 4 770-965 rpm Kit 4 770-965 rpm Kit 4 770-965 rpm 10 hp 10 hp 10 hp Kit 1 740-895 rpm Kit 1 740-895 rpm Kit 1 740-895 rpm Kit 2 870-1045 rpm Kit 2 870-1045 rpm Kit 2 870-1045 rpm Blower wheel nom. D x W - in. (2) 18 x 15 (2) 18 x 15 (2) 18 x 15 Filters Type of filter Fiberglass, disposable Number and size - in. (12) 20 x 20 x 2 Electrical characteristics 208/230V, 460V or 575V - 60 hertz - 3 phase Cooling Performance NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 AHRI Certified to AHRI Standard 340/360; 95°F outdoor air temperature and 80°F db/67°F wb entering evaporator air; minimum external duct static pressure. 2 Integrated Energy Efficiency Ratio tested at according to AHRI Standard 340/360. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 15 SPECIFICATIONS - GAS HEAT LGH242 LGH300 LGH360 Model Number Usage Data Heat Input Type Standard (S) Medium (M) High (H) 2 2 2 First Stage 169,000 234,000 312,000 Second Stage 260,000 360,000 480,000 --- --- --- Second Stage 208,000 288,000 384,000 Temperature Rise Range - °F 10 - 40 15 - 45 20 - 50 Thermal Efficiency 80.0% 80.0% 80.0% 1 in. NPT 1 in. NPT 1 in. NPT Natural 7 7 7 LPG/Propane 11 11 11 Number of Gas Heat Stages Gas Heating Input - Btuh Performance Output - Btuh First Stage Gas Supply Connections Recommended Gas Supply Pressure - in. w.g. HIGH ALTITUDE DERATE Units may be installed at altitudes up to 2000 feet above sea level without any modification. At altitudes above 2000 feet, units must be derated to match gas manifold pressures shown in table below. At altitudes above 4500 feet unit must be derated 2% for each 1000 feet above sea level. NOTE - This is the only permissible derate for these units. Gas Heat Type Altitude - ft. Standard (S) Gas Manifold Pressure - in. w.g. Input Rate Natural Gas or LPG/Propane - Btuh Natural Gas LPG/Propane Gas First Stage Second Stage 2001 - 4500 3.4 9.6 169,000 249,000 Medium (M) 2001 - 4500 3.4 9.6 234,000 345,000 High (H) 2001 - 4500 3.4 9.6 312,000 460,000 E-Series Packaged Gas / Electric 20 to 30 Ton / Page 16 RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin − Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 20 TON HIGH EFFICIENCY LGH242H4V (1 COMRESSOR OPERATING) - VARIABLE AIR VOLUME Outdoor Air Temperature Entering Outdoor Coil Entering 65°F 75°F 85°F 95°F Total Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Cool Motor Cool Motor Cool Motor TemperCap. Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb ature cfm kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 1600 47.7 2.44 .63 .71 .79 46.4 2.83 .64 .71 .79 45.0 3.25 .63 .71 .80 43.5 3.72 .63 .72 .81 63°F 2000 51.4 2.44 .63 .73 .82 50.3 2.83 .64 .74 .83 49.0 3.26 .64 .74 .84 47.2 3.73 .65 .75 .85 2400 54.8 2.44 .65 .76 .86 53.6 2.84 .66 .77 .87 52.1 3.27 .66 .77 .88 50.1 3.75 .67 .79 .90 1600 49.3 2.44 .52 .59 .67 48.3 2.83 .52 .59 .67 47.0 3.25 .52 .60 .68 45.5 3.73 .52 .61 .69 67°F 2000 53.8 2.44 .53 .61 .70 52.7 2.83 .53 .61 .70 51.2 3.27 .53 .62 .71 49.4 3.74 .53 .63 .72 2400 57.3 2.44 .54 .63 .72 56.1 2.84 .54 .63 .73 54.5 3.28 .54 .64 .74 52.5 3.75 .55 .64 .75 1600 51.3 2.44 .42 .50 .57 50.2 2.83 .42 .50 .57 48.9 3.26 .42 .50 .58 47.3 3.74 .42 .50 .58 71°F 2000 56.0 2.44 .42 .51 .58 54.8 2.84 .42 .51 .59 53.3 3.27 .42 .51 .60 51.4 3.75 .42 .52 .60 2400 59.7 2.43 .42 .52 .60 58.4 2.84 .42 .52 .61 56.7 3.28 .42 .52 .61 54.6 3.75 .42 .53 .62 20 TON HIGH EFFICIENCY LGH242H4V (2 COMRESSORS OPERATING) - VARIABLE AIR VOLUME Entering Total Wet Air Bulb Volume Temperature cfm 3200 63°F 4000 4800 3200 67°F 4000 4800 3200 71°F 4000 4800 Total Cool Cap. kBtuh 104.1 111.4 117.5 110.3 118.4 124.7 116.5 125.2 131.9 Outdoor Air Temperature Entering Outdoor Coil 65°F 75°F 85°F 95°F Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Motor Cool Motor Cool Motor Cool Motor Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 4.89 .63 .71 .78 101.4 5.67 .63 .71 .78 98.3 6.52 .63 .72 .79 94.6 7.46 .63 .72 .80 4.89 .64 .72 .81 108.5 5.68 .64 .73 .82 105.2 6.54 .63 .74 .83 101.0 7.48 .65 .75 .84 4.89 .65 .76 .85 114.3 5.69 .65 .76 .85 110.4 6.55 .66 .77 .87 106.3 7.50 .67 .79 .88 4.89 .52 .59 .67 107.2 5.68 .52 .59 .67 104.2 6.54 .52 .59 .68 100.4 7.48 .52 .60 .68 4.89 .52 .60 .69 115.2 5.69 .52 .61 .70 111.6 6.56 .53 .62 .70 107.3 7.50 .53 .62 .72 4.89 .53 .63 .72 121.2 5.69 .53 .63 .73 117.1 6.57 .54 .64 .74 112.6 7.52 .55 .64 .75 4.89 .42 .50 .56 113.5 5.69 .42 .50 .57 110.3 6.56 .42 .50 .57 106.3 7.50 .42 .50 .57 4.89 .42 .50 .58 121.9 5.69 .42 .50 .58 118.1 6.57 .41 .51 .59 113.7 7.53 .42 .51 .60 4.88 .42 .51 .60 128.4 5.70 .42 .51 .61 124.1 6.58 .42 .52 .61 119.2 7.54 .42 .52 .62 20 TON HIGH EFFICIENCY LGH242H4V (3 COMRESSORS OPERATING) - VARIABLE AIR VOLUME Entering Total Wet Air Bulb Volume Temperature cfm 4800 63°F 6000 7200 4800 67°F 6000 7200 4800 71°F 6000 7200 Total Cool Cap. kBtuh 185.8 195.8 204.9 196.3 206.1 213.1 206.6 216.6 221.5 Outdoor Air Temperature Entering Outdoor Coil 65°F 75°F 85°F 95°F Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Motor Cool Motor Cool Motor Cool Motor Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 7.35 .69 .82 .90 180.3 8.57 .70 .83 .90 173.8 9.86 .71 .84 .91 166.8 11.27 .72 .86 .92 7.35 .73 .87 .93 190.3 8.57 .74 .87 .94 183.9 9.88 .76 .88 .95 176.8 11.31 .77 .89 .96 7.34 .77 .89 .96 199.1 8.58 .78 .90 .97 192.3 9.90 .80 .91 .98 184.5 11.33 .82 .92 .99 7.35 .56 .67 .78 190.6 8.57 .56 .67 .79 183.6 9.88 .56 .68 .81 176.1 11.30 .57 .69 .82 7.34 .58 .71 .84 199.7 8.58 .59 .72 .85 192.5 9.90 .59 .73 .86 183.9 11.32 .59 .74 .87 7.34 .60 .75 .87 206.5 8.58 .61 .76 .88 198.8 9.91 .62 .77 .89 190.0 11.34 .63 .79 .90 7.34 .43 .54 .65 200.6 8.58 .43 .54 .65 193.6 9.90 .43 .55 .66 185.6 11.33 .43 .56 .67 7.34 .44 .55 .66 210.6 8.58 .44 .57 .70 202.9 9.91 .44 .57 .70 194.2 11.35 .45 .59 .72 7.34 .45 .56 .68 217.8 8.58 .45 .60 .73 209.5 9.92 .45 .61 .75 200.3 11.37 .46 .62 .77 20 TON HIGH EFFICIENCY LGH242H4V (All COMRESSORS OPERATING) - VARIABLE AIR VOLUME Entering Total Wet Air Bulb Volume Temperature cfm 6400 63°F 8000 9600 6400 67°F 8000 9600 6400 71°F 8000 9600 Total Cool Cap. kBtuh 242.1 255.3 265.0 252.7 263.7 272.2 267.2 278.7 286.6 Outdoor Air Temperature Entering Outdoor Coil 85°F 95°F 105°F 115°F Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Motor Cool Motor Cool Motor Cool Motor Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 13.17 .71 .83 .94 232.8 15.08 .72 .84 .96 222.2 17.18 .74 .86 .98 210.4 19.57 .75 .88 1.00 13.19 .75 .89 1.00 244.9 15.10 .77 .91 1.00 233.4 17.21 .79 .93 1.00 220.8 19.61 .81 .96 1.00 13.21 .80 .95 1.00 254.0 15.13 .82 .97 1.00 242.0 17.25 .84 .99 1.00 229.0 19.65 .86 1.00 1.00 13.19 .55 .68 .80 241.9 15.09 .57 .70 .81 230.5 17.20 .57 .71 .83 217.4 19.59 .58 .72 .85 13.21 .58 .72 .86 252.3 15.13 .59 .74 .88 239.9 17.24 .61 .77 .90 226.6 19.63 .61 .78 .93 13.22 .61 .78 .92 260.5 15.15 .62 .79 .94 247.9 17.27 .64 .81 .97 234.3 19.68 .66 .84 .99 13.21 .43 .55 .66 256.0 15.13 .43 .55 .67 243.5 17.26 .43 .56 .68 230.0 19.65 .43 .57 .70 13.23 .43 .57 .70 266.5 15.17 .43 .58 .72 253.2 17.29 .44 .60 .74 238.3 19.70 .44 .61 .76 13.24 .43 .60 .76 273.6 15.18 .44 .62 .78 259.6 17.32 .45 .63 .80 244.0 19.72 .46 .64 .82 E-Series Packaged Gas / Electric 20 to 30 Ton / Page 17 RATINGS NOTE - For Temperatures and Capacities not shown in tables, see bulletin - Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 25 TON HIGH EFFICIENCY LGH300H4B (1ST STAGE) - CONSTANT AIR VOLUME Outdoor Air Temperature Entering Outdoor Coil Entering 65°F 75°F 85°F 95°F Total Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Cool Motor Cool Motor Cool Motor TemperCap. Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb ature cfm kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 8000 157.5 7.35 .71 .83 .95 152.9 8.21 .72 .84 .96 147.7 9.16 .73 .86 .97 142.1 10.27 .74 .87 .99 63°F 10,000 166.1 7.48 .76 .89 1.00 160.7 8.33 .77 .91 1.00 155.1 9.29 .78 .92 1.00 149.2 10.38 .79 .94 1.00 12,000 172.3 7.58 .80 .95 1.00 166.6 8.42 .81 .96 1.00 161.0 9.38 .82 .98 1.00 154.8 10.47 .84 .99 1.00 8000 167.0 7.50 .57 .69 .80 162.0 8.35 .57 .70 .81 156.5 9.30 .58 .70 .82 150.5 10.39 .59 .72 .84 67°F 10,000 175.4 7.63 .60 .73 .86 169.5 8.47 .60 .75 .88 163.5 9.42 .61 .75 .89 157.4 10.51 .62 .77 .91 12,000 181.0 7.73 .62 .78 .92 175.3 8.57 .63 .79 .94 168.9 9.51 .64 .80 .95 162.2 10.59 .65 .82 .97 8000 177.4 7.67 .44 .56 .67 171.9 8.51 .44 .56 .67 166.0 9.46 .44 .56 .68 159.9 10.55 .45 .57 .69 71°F 10,000 185.7 7.80 .45 .58 .71 179.9 8.64 .45 .59 .72 173.6 9.59 .46 .59 .74 166.8 10.67 .46 .60 .75 12,000 191.7 7.91 .46 .61 .76 185.6 8.74 .46 .62 .77 179.3 9.69 .47 .63 .78 171.7 10.77 .47 .64 .80 25 TON HIGH EFFICIENCY LGH300H4B (2ND STAGE) - CONSTANT AIR VOLUME Entering Total Wet Air Bulb Volume Temperature cfm 8000 63°F 10,000 12,000 8000 67°F 10,000 12,000 8000 71°F 10,000 12,000 Total Cool Cap. kBtuh 297.0 311.1 322.4 314.5 328.8 339.5 332.9 348.0 359.1 Outdoor Air Temperature Entering Outdoor Coil 85°F 95°F 105°F 115°F Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Motor Cool Motor Cool Motor Cool Motor Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 18.34 .73 .86 .98 286.0 20.54 .74 .88 .99 273.7 23.12 .76 .90 1.00 258.8 26.15 .78 .92 1.00 18.57 .79 .93 1.00 299.8 20.78 .80 .95 1.00 286.9 23.34 .82 .97 1.00 271.4 26.33 .84 .99 1.00 18.75 .83 .99 1.00 310.6 20.94 .85 1.00 1.00 298.6 23.53 .87 1.00 1.00 284.7 26.56 .89 1.00 1.00 18.62 .58 .71 .83 303.4 20.82 .59 .72 .84 290.4 23.40 .60 .73 .86 274.7 26.40 .61 .75 .89 18.86 .61 .76 .90 316.7 21.05 .62 .78 .92 303.1 23.61 .63 .79 .94 286.3 26.57 .64 .81 .97 19.04 .65 .81 .96 326.4 21.22 .65 .83 .98 312.3 23.78 .66 .84 1.00 295.1 26.73 .68 .87 1.00 18.93 .44 .57 .68 321.2 21.12 .45 .57 .70 308.2 23.70 .45 .58 .71 291.7 26.66 .45 .59 .73 19.19 .46 .60 .74 335.4 21.38 .46 .61 .75 321.5 23.94 .46 .62 .77 304.1 26.89 .47 .63 .79 19.39 .47 .64 .79 345.3 21.55 .47 .64 .80 330.3 24.10 .48 .66 .82 312.3 27.06 .48 .67 .85 E-Series Packaged Gas / Electric 20 to 30 Ton / Page 18 RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin − Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 25 TON HIGH EFFICIENCY LGH300H4V (1 COMRESSOR OPERATING) - VARIABLE AIR VOLUME Outdoor Air Temperature Entering Outdoor Coil Entering 65°F 75°F 85°F 95°F Total Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Cool Motor Cool Motor Cool Motor TemperCap. Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb ature cfm kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 2000 62.5 3.65 .63 .71 .78 60.6 4.07 .63 .71 .79 58.3 4.57 .64 .71 .80 55.9 5.13 .63 .72 .81 63°F 2500 67.8 3.68 .63 .72 .81 65.7 4.10 .63 .73 .82 63.5 4.59 .64 .74 .83 60.9 5.15 .65 .75 .84 3000 72.4 3.73 .64 .74 .84 70.1 4.15 .65 .75 .85 67.6 4.63 .66 .76 .87 64.9 5.19 .67 .78 .88 2000 65.5 3.67 .53 .60 .67 62.9 4.09 .53 .60 .67 60.8 4.58 .52 .60 .68 58.6 5.15 .52 .61 .68 67°F 2500 71.0 3.72 .52 .60 .69 68.8 4.14 .53 .61 .69 66.5 4.62 .53 .62 .70 63.9 5.18 .53 .62 .71 3000 75.9 3.76 .53 .62 .71 73.5 4.17 .53 .62 .72 71.0 4.64 .54 .63 .73 68.1 5.20 .54 .64 .74 2000 67.4 3.68 .42 .50 .56 65.4 4.11 .42 .50 .57 63.4 4.59 .42 .50 .58 61.0 5.16 .42 .50 .58 71°F 2500 73.8 3.73 .42 .51 .58 71.6 4.15 .42 .51 .59 69.2 4.63 .42 .51 .59 66.6 5.19 .42 .51 .60 3000 79.1 3.79 .42 .51 .59 76.7 4.20 .42 .52 .60 73.9 4.67 .42 .52 .61 71.0 5.23 .43 .53 .62 25 TON HIGH EFFICIENCY LGH300H4V (2 COMRESSORS OPERATING) - VARIABLE AIR VOLUME Entering Total Wet Air Bulb Volume Temperature cfm 4000 63°F 5000 6000 4000 67°F 5000 6000 4000 71°F 5000 6000 Total Cool Cap. kBtuh 136.4 147.1 154.8 144.9 155.8 164.5 153.0 165.0 174.2 Outdoor Air Temperature Entering Outdoor Coil 65°F 75°F 85°F 95°F Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Motor Cool Motor Cool Motor Cool Motor Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 7.46 .60 .68 .75 132.1 8.29 .62 .71 .78 127.4 9.23 .63 .71 .79 122.1 10.31 .63 .71 .80 7.52 .64 .72 .80 141.9 8.37 .63 .72 .81 136.6 9.31 .64 .74 .83 130.8 10.40 .64 .74 .84 7.59 .64 .74 .84 149.7 8.44 .65 .75 .85 144.0 9.38 .66 .77 .86 137.7 10.44 .67 .77 .87 7.51 .53 .60 .67 140.4 8.35 .52 .60 .67 135.2 9.31 .52 .60 .68 129.7 10.37 .52 .60 .68 7.61 .52 .60 .68 150.9 8.44 .53 .61 .69 145.3 9.39 .52 .61 .70 139.2 10.46 .52 .62 .70 7.70 .53 .62 .71 159.1 8.53 .53 .62 .72 153.0 9.46 .53 .63 .73 146.3 10.53 .54 .64 .74 7.58 .43 .50 .56 148.3 8.42 .42 .49 .57 143.2 9.37 .42 .49 .57 137.7 10.45 .42 .50 .57 7.71 .42 .50 .58 159.7 8.52 .42 .50 .58 154.2 9.47 .42 .50 .59 147.8 10.55 .42 .50 .59 7.79 .42 .51 .59 168.5 8.62 .42 .51 .60 161.9 9.56 .42 .52 .60 155.1 10.63 .42 .52 .61 25 TON HIGH EFFICIENCY LGH300H4V (3 COMRESSORS OPERATING) - VARIABLE AIR VOLUME Entering Total Wet Air Bulb Volume Temperature cfm 6000 63°F 7500 9000 6000 67°F 7500 9000 6000 71°F 7500 9000 Total Cool Cap. kBtuh 244.0 257.4 268.0 258.2 271.7 281.6 271.7 285.8 296.5 Outdoor Air Temperature Entering Outdoor Coil 65°F 75°F 85°F 95°F Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Motor Cool Motor Cool Motor Cool Motor Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 11.46 .68 .80 .89 235.6 12.72 .69 .81 .90 226.3 14.12 .70 .83 .91 216.2 15.72 .71 .84 .92 11.61 .71 .85 .92 248.3 12.85 .72 .87 .93 238.2 14.24 .74 .88 .94 228.3 15.86 .75 .88 .95 11.73 .75 .88 .95 259.1 12.98 .76 .89 .96 249.3 14.38 .78 .90 .97 238.7 16.00 .80 .91 .98 11.63 .55 .66 .76 249.3 12.87 .56 .67 .78 239.4 14.27 .56 .68 .79 228.9 15.87 .57 .69 .81 11.78 .57 .69 .82 261.9 13.01 .57 .70 .84 251.3 14.41 .58 .71 .85 239.7 16.00 .59 .73 .86 11.89 .59 .73 .86 271.1 13.12 .60 .74 .87 259.6 14.52 .60 .76 .88 247.2 16.11 .62 .78 .89 11.78 .43 .54 .63 262.5 13.03 .43 .54 .64 252.1 14.43 .43 .55 .65 241.3 16.03 .43 .55 .66 11.95 .44 .56 .67 275.7 13.19 .44 .56 .68 264.9 14.59 .44 .57 .69 252.7 16.18 .44 .58 .71 12.08 .44 .58 .71 285.5 13.32 .44 .59 .72 273.8 14.71 .45 .60 .73 261.0 16.30 .45 .60 .75 25 TON HIGH EFFICIENCY LGH300H4V (All COMRESSORS OPERATING) - VARIABLE AIR VOLUME Entering Total Wet Air Bulb Volume Temperature cfm 8000 63°F 10,000 12,000 8000 67°F 10,000 12,000 8000 71°F 10,000 12,000 Total Cool Cap. kBtuh 313.6 331.2 343.8 329.7 343.7 353.8 348.3 362.9 374.1 Outdoor Air Temperature Entering Outdoor Coil 85°F 95°F 105°F 115°F Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Motor Cool Motor Cool Motor Cool Motor Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 18.86 .70 .82 .92 300.2 21.00 .72 .84 .94 286.1 23.49 .73 .85 .97 271.0 26.45 .74 .87 .99 19.10 .75 .88 .99 316.5 21.24 .76 .89 1.00 300.8 23.69 .78 .92 1.00 284.4 26.62 .80 .94 1.00 19.26 .79 .93 1.00 327.9 21.39 .81 .95 1.00 311.9 23.86 .83 .98 1.00 294.8 26.79 .85 1.00 1.00 19.08 .56 .68 .79 314.1 21.18 .56 .69 .81 297.8 23.65 .57 .70 .82 280.9 26.56 .58 .72 .84 19.27 .58 .72 .85 327.1 21.38 .59 .74 .86 310.3 23.83 .60 .75 .89 292.8 26.74 .61 .77 .91 19.41 .60 .77 .90 337.3 21.53 .62 .78 .92 320.3 24.00 .62 .80 .95 302.4 26.91 .64 .82 .97 19.33 .42 .54 .66 332.0 21.45 .43 .55 .66 315.2 23.91 .43 .56 .68 298.3 26.83 .43 .56 .70 19.55 .43 .57 .70 345.7 21.65 .44 .58 .72 328.1 24.11 .43 .58 .74 309.1 27.00 .43 .60 .75 19.72 .43 .59 .75 356.2 21.83 .44 .60 .76 336.6 24.26 .44 .62 .78 317.0 27.15 .45 .63 .81 E-Series Packaged Gas / Electric 20 to 30 Ton / Page 19 RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin − Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 30 TON HIGH EFFICIENCY LGH360H4B (1ST STAGE) - CONSTANT AIR VOLUME Outdoor Air Temperature Entering Outdoor Coil Entering 65°F 75°F 85°F 95°F Total Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Cool Motor Cool Motor Cool Motor TemperCap. Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb ature cfm kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 9440 188.9 9.57 .70 .82 .94 183.2 10.61 .71 .83 .95 177.5 11.79 .72 .84 .97 171.1 13.16 .73 .86 .98 63°F 11,800 198.4 9.73 .74 .88 1.00 192.0 10.76 .75 .90 1.00 185.9 11.95 .77 .91 1.00 179.1 13.31 .78 .93 1.00 14,160 205.4 9.86 .79 .94 1.00 198.6 10.89 .80 .96 1.00 192.2 12.07 .81 .98 1.00 185.4 13.44 .82 .99 1.00 9440 200.0 9.76 .56 .68 .79 193.9 10.80 .56 .69 .80 187.6 11.98 .57 .69 .82 181.0 13.35 .58 .70 .83 67°F 11,800 208.7 9.92 .58 .72 .85 201.9 10.95 .59 .73 .87 195.3 12.13 .60 .74 .88 188.1 13.50 .60 .75 .90 14,160 214.9 10.04 .61 .77 .91 207.8 11.07 .62 .78 .93 201.0 12.24 .63 .79 .95 193.7 13.61 .64 .81 .97 9440 211.2 9.97 .43 .55 .66 204.6 11.00 .43 .55 .66 198.0 12.19 .44 .55 .67 190.9 13.55 .44 .56 .68 71°F 11,800 220.0 10.14 .44 .57 .70 212.9 11.17 .45 .58 .71 206.2 12.35 .45 .59 .72 198.7 13.72 .45 .59 .74 14,160 226.9 10.27 .45 .60 .74 219.3 11.30 .45 .61 .76 212.1 12.47 .46 .62 .77 204.8 13.83 .46 .63 .79 30 TON HIGH EFFICIENCY LGH360H4B (2ND STAGE) - CONSTANT AIR VOLUME Entering Total Wet Air Bulb Volume Temperature cfm 9440 63°F 11,800 14,160 9440 67°F 11,800 14,160 9440 71°F 11,800 14,160 Total Cool Cap. kBtuh 357.8 374.0 386.3 377.9 394.0 405.1 397.8 414.7 426.1 Outdoor Air Temperature Entering Outdoor Coil 85°F 95°F 105°F 115°F Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Motor Cool Motor Cool Motor Cool Motor Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 23.62 .72 .85 .98 344.2 26.32 .73 .86 .99 329.7 29.45 .74 .88 1.00 312.8 33.05 .76 .91 1.00 23.92 .77 .92 1.00 359.3 26.61 .78 .94 1.00 344.3 29.76 .80 .96 1.00 326.5 33.33 .82 .99 1.00 24.16 .82 .98 1.00 371.9 26.86 .83 .99 1.00 356.7 30.00 .85 1.00 1.00 339.4 33.62 .88 1.00 1.00 24.00 .57 .70 .82 363.8 26.69 .58 .70 .83 348.6 29.83 .58 .72 .85 330.1 33.41 .59 .74 .88 24.30 .60 .75 .89 378.6 27.01 .61 .76 .91 362.1 30.12 .62 .78 .93 342.8 33.70 .63 .80 .96 24.53 .63 .80 .96 389.4 27.22 .64 .81 .98 372.2 30.34 .65 .83 .99 351.5 33.90 .66 .86 1.00 24.40 .44 .56 .67 383.1 27.09 .44 .56 .68 367.4 30.23 .44 .57 .69 348.2 33.82 .44 .58 .71 24.72 .45 .59 .73 398.8 27.42 .45 .60 .74 381.6 30.55 .45 .61 .76 361.3 34.12 .46 .62 .78 24.95 .46 .62 .78 410.7 27.65 .46 .63 .79 391.6 30.75 .47 .64 .81 370.0 34.32 .47 .66 .84 E-Series Packaged Gas / Electric 20 to 30 Ton / Page 20 RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin − Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 30 TON HIGH EFFICIENCY LGH360H4V (1 COMRESSOR OPERATING) - VARIABLE AIR VOLUME Outdoor Air Temperature Entering Outdoor Coil Entering 65°F 75°F 85°F 95°F Total Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Cool Motor Cool Motor Cool Motor TemperCap. Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb ature cfm kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 2360 73.4 4.44 .64 .72 .79 71.1 4.96 .64 .72 .80 68.6 5.54 .65 .73 .80 65.8 6.19 .64 .73 .82 63°F 2950 78.9 4.53 .65 .73 .82 76.5 5.05 .65 .74 .83 73.9 5.63 .66 .75 .84 71.0 6.29 .66 .76 .86 3540 83.8 4.60 .66 .76 .85 81.1 5.13 .67 .77 .87 78.2 5.70 .67 .78 .88 75.1 6.36 .68 .79 .90 2360 76.2 4.49 .54 .61 .68 73.7 5.00 .53 .61 .68 71.3 5.59 .53 .61 .69 68.7 6.25 .53 .62 .70 67°F 2950 82.4 4.58 .54 .62 .70 79.9 5.10 .54 .62 .71 77.2 5.68 .54 .63 .72 74.3 6.35 .54 .64 .73 3540 87.5 4.66 .54 .64 .73 84.8 5.19 .55 .64 .73 81.9 5.77 .55 .65 .75 78.5 6.43 .55 .66 .76 2360 78.8 4.53 .43 .51 .58 76.6 5.05 .43 .51 .58 74.2 5.64 .43 .51 .59 71.4 6.29 .42 .51 .59 71°F 2950 85.6 4.63 .43 .51 .59 83.1 5.16 .43 .52 .60 80.3 5.74 .43 .52 .61 77.1 6.40 .43 .52 .61 3540 90.9 4.72 .43 .53 .61 88.2 5.25 .43 .53 .62 85.1 5.83 .43 .53 .62 81.7 6.49 .43 .54 .63 30 TON HIGH EFFICIENCY LGH360H4V (2 COMRESSORS OPERATING) - VARIABLE AIR VOLUME Entering Total Wet Air Bulb Volume Temperature cfm 4720 63°F 5900 7080 4720 67°F 5900 7080 4720 71°F 5900 7080 Total Cool Cap. kBtuh 186.4 196.1 203.0 194.7 205.3 212.6 202.3 213.3 221.4 Outdoor Air Temperature Entering Outdoor Coil 65°F 75°F 85°F 95°F Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Motor Cool Motor Cool Motor Cool Motor Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 9.54 .69 .81 .92 180.5 10.59 .70 .82 .93 173.7 11.74 .71 .83 .95 165.8 13.04 .72 .85 .97 9.70 .72 .86 .98 189.6 10.74 .73 .87 1.00 182.0 11.90 .75 .89 1.00 173.6 13.19 .76 .91 1.00 9.82 .76 .91 1.00 196.3 10.86 .77 .93 1.00 188.4 12.02 .79 .95 1.00 179.5 13.31 .80 .97 1.00 9.68 .56 .67 .77 188.7 10.73 .56 .68 .78 181.5 11.89 .57 .69 .80 173.7 13.20 .58 .70 .82 9.86 .58 .70 .83 198.5 10.91 .59 .71 .84 190.5 12.06 .59 .72 .86 181.9 13.36 .60 .74 .88 9.99 .60 .74 .88 205.5 11.03 .61 .75 .90 197.1 12.19 .62 .76 .92 188.1 13.48 .63 .78 .94 9.81 .44 .54 .65 196.1 10.87 .44 .55 .65 188.9 12.03 .44 .55 .66 180.6 13.33 .44 .56 .67 10.01 .44 .57 .68 206.5 11.05 .45 .57 .69 198.4 12.21 .45 .58 .70 189.5 13.51 .45 .59 .72 10.15 .45 .59 .72 214.2 11.20 .46 .60 .73 205.6 12.36 .46 .60 .74 196.2 13.66 .47 .62 .76 30 TON HIGH EFFICIENCY LGH360H4V (3 COMRESSORS OPERATING) - VARIABLE AIR VOLUME Entering Total Wet Air Bulb Volume Temperature cfm 7080 63°F 8850 10,620 7080 67°F 8850 10,620 7080 71°F 8850 10,620 Total Cool Cap. kBtuh 284.0 297.7 308.5 298.7 312.7 322.7 313.1 327.5 338.1 Outdoor Air Temperature Entering Outdoor Coil 65°F 75°F 85°F 95°F Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Motor Cool Motor Cool Motor Cool Motor Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 14.37 .70 .81 .90 276.6 15.96 .70 .82 .91 266.5 17.72 .71 .83 .91 254.1 19.67 .72 .85 .92 14.60 .73 .86 .93 289.8 16.19 .74 .87 .94 278.4 17.94 .75 .88 .95 266.3 19.90 .76 .89 .96 14.79 .76 .90 .96 300.6 16.39 .78 .90 .97 289.6 18.15 .79 .91 .98 277.1 20.12 .81 .92 .99 14.62 .56 .67 .78 291.1 16.22 .56 .67 .79 280.2 17.97 .57 .68 .80 267.6 19.93 .57 .70 .82 14.87 .58 .71 .83 304.4 16.46 .59 .71 .85 292.6 18.21 .59 .73 .86 279.0 20.16 .60 .74 .87 15.04 .60 .74 .88 313.8 16.63 .61 .76 .89 301.3 18.37 .62 .77 .89 286.6 20.31 .63 .79 .90 14.87 .44 .55 .65 305.1 16.47 .44 .55 .66 294.0 18.24 .44 .55 .66 280.9 20.21 .44 .56 .68 15.13 .44 .57 .68 319.0 16.72 .44 .57 .69 306.9 18.49 .45 .58 .71 292.5 20.44 .44 .59 .72 15.34 .44 .59 .70 329.0 16.92 .44 .60 .73 316.1 18.66 .44 .61 .75 301.3 20.61 .45 .62 .77 30 TON HIGH EFFICIENCY LGH360H4V (All COMRESSORS OPERATING) - VARIABLE AIR VOLUME Entering Total Wet Air Bulb Volume Temperature cfm 9440 63°F 11,800 14,160 9440 67°F 11,800 14,160 9440 71°F 11,800 14,160 Total Cool Cap. kBtuh 366.3 384.4 397.6 383.7 397.9 409.2 404.0 418.6 428.9 Outdoor Air Temperature Entering Outdoor Coil 85°F 95°F 105°F 115°F Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Motor Cool Motor Cool Motor Cool Motor Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 23.80 .71 .83 .93 350.4 26.42 .72 .84 .95 334.3 29.43 .74 .86 .97 318.4 33.05 .75 .88 .99 24.14 .76 .88 .99 367.3 26.75 .77 .90 1.00 349.4 29.75 .79 .92 1.00 332.3 33.36 .81 .94 1.00 24.39 .80 .94 1.00 379.4 27.00 .82 .96 1.00 360.6 29.98 .84 .98 1.00 343.1 33.60 .86 1.00 1.00 24.13 .56 .68 .80 366.0 26.73 .57 .70 .82 347.3 29.71 .58 .71 .83 329.4 33.30 .59 .73 .85 24.40 .59 .73 .86 379.2 26.99 .59 .75 .88 359.9 29.97 .61 .77 .90 341.4 33.56 .62 .78 .92 24.62 .61 .79 .91 389.2 27.19 .63 .80 .93 369.7 30.18 .64 .82 .95 350.8 33.77 .65 .84 .98 24.52 .42 .55 .66 385.1 27.11 .42 .55 .67 365.8 30.10 .43 .56 .70 347.0 33.68 .43 .57 .70 24.81 .43 .58 .71 398.9 27.39 .44 .58 .73 377.9 30.37 .43 .60 .75 358.4 33.92 .44 .61 .77 25.02 .44 .61 .76 408.3 27.60 .44 .62 .78 386.6 30.55 .46 .64 .81 365.8 34.09 .47 .65 .83 E-Series Packaged Gas / Electric 20 to 30 Ton / Page 21 E-Series Packaged Gas / Electric 20 to 30 Ton / Page 22 680 704 727 750 13,500 14,500 15,000 657 13,000 14,000 613 635 12,000 12,500 572 592 11,000 11,500 553 10,500 2.36 516 534 9500 10,000 2.11 499 9000 1.66 7.23 6.55 5.92 5.35 4.83 4.37 3.95 3.58 3.24 2.93 2.64 1.88 467 483 1.46 8000 453 7500 1.26 1.07 0.89 0.73 0.56 0.41 0.26 BHP 8500 426 439 6500 7000 402 414 5500 392 5000 6000 372 382 4500 RPM 0.20 4000 Air Volume cfm 797 777 757 736 715 695 674 653 634 615 596 578 561 544 528 513 499 486 473 462 451 441 433 RPM 8.07 7.34 6.67 6.06 5.50 4.98 4.53 4.12 3.74 3.39 3.06 2.75 2.47 2.22 2.00 1.79 1.60 1.41 1.24 1.08 0.93 0.79 0.65 BHP 0.40 834 818 801 784 766 748 729 711 692 674 657 640 624 608 593 579 565 551 539 527 516 506 497 RPM 8.92 8.16 7.44 6.78 6.18 5.62 5.14 4.70 4.31 3.95 3.60 3.26 2.95 2.65 2.38 2.14 1.93 1.74 1.56 1.40 1.25 1.12 0.99 BHP 0.60 868 854 839 824 808 792 776 760 744 727 711 696 681 667 653 641 628 616 605 594 584 574 565 RPM 9.75 8.97 8.23 7.53 6.89 6.29 5.75 5.27 4.83 4.44 4.07 3.73 3.41 3.10 2.81 2.55 2.31 2.10 1.90 1.72 1.55 1.41 1.27 BHP 0.80 9.75 9.00 8.29 7.61 6.98 6.39 5.85 5.35 4.90 4.48 4.10 3.76 3.44 3.15 2.88 2.64 2.42 2.21 2.02 1.85 1.69 1.54 BHP 907 9.66 7.16 9.56 8.91 8.30 7.71 4.82 894 989 978 967 957 946 936 927 918 909 901 --- --- --- --- 3.56 916 992 982 972 962 953 945 937 929 922 997 988 979 971 964 957 951 944 938 932 RPM --- --- 994 987 980 974 --- RPM 4.91 4.60 4.30 4.01 --- BHP 6.39 1034 6.81 5.96 1025 6.37 5.56 1016 5.97 5.19 1008 5.59 4.85 1001 5.24 4.52 4.22 3.93 3.66 3.40 BHP 7.43 1028 7.86 1066 8.32 6.93 1018 7.34 1055 7.78 6.46 1007 6.85 1044 7.28 6.01 5.59 5.20 4.83 4.49 4.18 3.88 3.61 3.35 3.10 BHP 2.60 8.65 1025 9.10 1062 9.59 1101 10.12 8.09 1013 8.51 1050 8.98 1089 9.49 7.55 1003 7.96 1039 8.40 1077 8.89 7.03 6.54 6.07 5.63 5.22 4.83 4.48 4.15 3.84 909 903 897 RPM 2.40 --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- 9.42 1011 9.87 1048 10.35 1085 10.86 1124 11.42 8.80 1000 9.25 1036 9.71 1073 10.22 1112 10.77 8.21 7.65 7.12 6.61 6.12 5.65 5.22 880 887 3.30 3.05 2.82 BHP 2.20 988 10.06 1023 10.52 1059 11.00 - - - 976 965 954 943 932 921 910 900 890 4.45 4.11 3.80 3.51 874 868 861 RPM 2.00 965 10.24 1000 10.74 1035 11.20 - - - 953 941 8.98 930 8.33 918 6.62 6.12 895 5.64 884 5.19 4.78 881 872 4.04 4.39 864 857 850 3.24 3.00 837 843 2.77 2.56 BHP 831 824 RPM 3.72 3.43 3.16 2.92 2.70 2.50 2.30 BHP 873 862 852 843 833 825 817 809 802 796 790 784 RPM 7.71 7.13 6.58 6.06 5.57 5.11 4.69 4.30 3.95 3.63 3.34 3.07 2.83 2.61 2.41 2.22 2.04 BHP 1.80 943 10.38 977 10.94 1012 11.43 - - - 930 918 906 894 881 869 857 845 834 823 812 801 792 782 774 766 758 751 744 738 RPM 1.60 --- 9.72 9.00 8.32 7.67 7.06 6.49 5.95 5.46 5.00 4.58 4.20 3.85 3.53 3.24 2.97 2.73 2.51 2.31 2.12 1.95 1.79 BHP 1.40 922 10.48 955 11.12 - - - 909 896 883 870 857 843 830 817 805 792 780 768 757 747 737 727 718 710 702 694 687 RPM 1.20 TOTAL STATIC PRESSURE - In. w.g. 902 10.54 935 11.26 889 875 861 847 832 818 803 789 775 760 746 733 720 708 696 685 675 665 655 646 638 630 RPM 1.00 Then determine from blower table blower motor output and drive required. See page 23 for wet coil and option/accessory air resistance data. See page 23 for factory installed drive kit specifications. 1 - Wet indoor coil air resistance of selected unit. 2 - Any factory installed options air resistance (heat section, economizer, etc.) 3 - Any field installed accessories air resistance (duct resistance, diffuser, etc.) BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL & AIR FILTERS IN PLACE FOR ALL UNITS ADD: BLOWER DATA BLOWER DATA FACTORY INSTALLED BELT DRIVE KIT SPECIFICATIONS Motor Efficiency Nominal hp Maximum hp Drive Kit Number RPM Range Standard 5 5.75 5 660 - 810 Standard 5 5.75 6 770 - 965 Standard 5 5.75 7 570 - 720 Standard 5 5.75 8 480 - 630 Standard 5 5.75 9 410 - 535 Standard 7.5 8.63 3 715 - 880 Standard 7.5 8.63 4 770 - 965 Standard 10 11.50 1 740 - 895 Standard 10 11.50 2 870 - 1045 NOTE - Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. FACTORY INSTALLED OPTIONS/FIELD INSTALLED ACCESSORY AIR RESISTANCE Wet Indoor Coil Gas Heat Exchanger Filters MERV 8 MERV 13 Horizontal Roof Curb in. w.g. in. w.g. in. w.g. in. w.g. 0.11 0.00 0.00 0.00 0.04 0.10 0.13 0.00 0.00 0.00 0.05 0.10 0.12 0.15 0.00 0.00 0.00 0.06 0.13 0.11 0.14 0.17 0.01 0.00 0.01 0.07 6000 0.14 0.12 0.16 0.19 0.01 0.00 0.02 0.08 6500 0.16 0.13 0.18 0.21 0.01 0.01 0.02 0.09 7000 0.18 0.14 0.20 0.24 0.02 0.01 0.03 0.10 7500 0.20 0.15 0.21 0.25 0.02 0.01 0.04 0.11 8000 0.22 0.17 0.24 0.28 0.02 0.01 0.04 0.13 8500 0.24 0.20 0.27 0.31 0.03 0.01 0.04 0.15 9000 0.27 0.22 0.29 0.34 0.04 0.01 0.04 0.17 9500 0.29 0.24 0.32 0.38 0.04 0.02 0.06 0.19 10000 0.31 0.27 0.36 0.42 0.05 0.02 0.06 0.21 10500 0.33 0.30 0.40 0.46 0.06 0.02 0.06 0.24 11000 0.36 0.33 0.43 0.50 0.07 0.02 0.07 0.27 11500 0.39 0.37 0.48 0.55 0.08 0.02 0.08 0.30 12000 0.41 0.40 0.52 0.60 0.10 0.02 0.08 0.33 12500 0.44 0.44 0.57 0.65 0.11 0.03 0.10 0.37 13000 0.47 0.48 0.61 0.70 0.13 0.03 0.10 0.40 13500 0.49 0.53 0.67 0.76 0.14 0.03 0.11 0.44 14000 0.52 0.57 0.72 0.82 0.16 0.03 0.12 0.49 14500 0.55 0.62 0.78 0.89 0.18 0.04 0.13 0.53 15000 0.58 0.68 0.84 0.95 0.21 0.04 0.13 0.58 Air Volume cfm Standard Heat Medium Heat High Heat Economizer in. w.g. in. w.g. in. w.g. in. w.g. 4000 0.07 0.08 0.08 4500 0.09 0.09 5000 0.10 5500 E-Series Packaged Gas / Electric 20 to 30 Ton / Page 23 BLOWER DATA POWER EXHAUST FAN PERFORMANCE - STANDARD STATIC Return Duct Negative Static Pressure Air Volume Exhausted in. w.g. cfm 0.00 12,800 0.05 12,200 0.10 11,500 0.15 10,800 0.20 9900 0.25 9000 0.30 7900 0.35 6750 0.40 5450 0.45 4150 0.50 2900 POWER EXHAUST FANS - 50% HIGH STATIC OPERATION Air Volume cfm 4000 RETURN DUCT NEGATIVE STATIC PRESSURE - In. w.g. 0 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP --- --- --- --- 430 0.40 475 0.45 520 0.50 570 0.55 615 0.65 665 0.70 710 0.75 755 0.85 --- --- 4500 --- --- 415 0.45 460 0.55 500 0.60 545 0.65 585 0.70 625 0.80 670 0.85 710 0.95 750 1.00 795 1.10 5000 415 0.55 455 0.65 490 0.70 530 0.75 570 0.85 605 0.90 645 1.00 680 1.05 720 1.15 755 1.20 795 1.30 5500 460 0.75 495 0.85 525 0.90 560 0.95 595 1.05 630 1.10 665 1.20 700 1.30 735 1.35 765 1.45 800 1.55 6000 500 1.00 530 1.05 565 1.15 595 1.20 625 1.30 660 1.40 690 1.45 720 1.55 750 1.65 785 1.70 815 1.80 6500 540 1.25 570 1.30 600 1.40 630 1.50 660 1.60 685 1.65 715 1.75 745 1.85 775 1.95 805 2.05 830 2.10 7000 585 1.55 610 1.65 635 1.70 665 1.85 690 1.90 720 2.00 745 2.10 770 2.20 800 2.30 825 2.40 855 2.50 7500 625 1.90 650 2.00 675 2.10 700 2.20 725 2.30 750 2.40 775 2.50 800 2.60 825 2.70 850 2.80 875 2.90 8000 665 2.30 690 2.40 715 2.55 735 2.60 760 2.70 785 2.85 810 2.95 830 3.05 855 3.15 880 3.25 905 3.40 8500 710 2.80 730 2.90 755 3.00 775 3.10 795 3.20 820 3.35 840 3.45 865 3.55 885 3.65 910 3.80 930 3.90 POWER EXHAUST FANS - 100% HIGH STATIC OPERATION Air Volume cfm 8500 RETURN DUCT NEGATIVE STATIC PRESSURE - In. w.g. 0 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 475 1.30 500 1.30 525 1.40 550 1.50 585 1.60 625 1.75 670 1.90 710 2.10 745 2.30 780 2.50 815 2.70 9000 520 1.55 535 1.60 550 1.65 570 1.70 605 1.85 640 1.95 685 2.15 720 2.35 760 2.55 790 2.75 825 3.00 9500 550 1.80 560 1.85 575 1.90 600 2.00 620 2.10 655 2.20 695 2.40 735 2.60 770 2.80 800 3.00 835 3.25 10,000 575 2.10 590 2.15 605 2.20 620 2.30 645 2.40 675 2.50 710 2.65 745 2.85 780 3.05 815 3.30 845 3.50 10,500 605 2.45 615 2.45 625 2.50 645 2.60 670 2.75 690 2.80 725 3.00 755 3.15 790 3.35 825 3.60 855 3.80 11,000 630 2.80 645 2.85 660 2.95 675 3.00 685 3.05 715 3.20 740 3.30 770 3.50 805 3.70 835 3.90 870 4.20 11,500 665 3.25 675 3.30 680 3.30 695 3.40 715 3.50 735 3.60 755 3.70 785 3.85 815 4.05 850 4.30 880 4.50 12,000 685 3.60 700 3.70 710 3.75 725 3.85 740 3.95 755 4.00 780 4.15 805 4.30 830 4.45 860 4.65 890 4.90 12,500 720 4.10 730 4.20 740 4.25 750 4.30 765 4.40 780 4.50 800 4.60 820 4.75 845 4.90 875 5.10 905 5.35 13,000 745 4.60 750 4.65 765 4.75 780 4.85 790 4.90 805 5.00 820 5.10 840 5.25 865 5.40 890 5.60 915 5.80 13,500 775 5.15 785 5.25 795 5.35 805 5.40 815 5.50 830 5.60 845 5.70 865 5.80 880 5.95 905 6.10 930 6.30 14,000 805 5.80 810 5.80 820 5.90 830 6.00 845 6.10 855 6.20 870 6.30 885 6.40 905 6.55 925 6.70 --- HIGH STATIC POWER EXHAUST FANS WITH CONSTANT AIR VOLUME − DRIVE KIT SPECIFICATIONS Power Exhaust Fan Model No. Motor HP Drive Kit Number RPM Range LAPEB30/36A (50%) (2) 2 hp 1 406 - 533 LAPEB30/36B (50%) (2) 2 hp 2 531 - 731 LAPEB30/36C (50%) (2) 2 hp 3 731 - 932 LAPEB30/36D (100%) (3) 2 hp 1 406 - 533 LAPEB30/36E (100%) (3) 2 hp 2 531 - 731 LAPEB30/36F (100%) (3) 2 hp 3 731 - 932 NOTE − Using total air volume and system static pressure requirements, determine from blower performance tables rpm and motor output required. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 24 --- BLOWER DATA CEILING DIFFUSER AIR RESISTANCE - in. w.g. Step-Down Diffuser Air Volume cfm Flush Diffuser LARTD30/36 LAFD30/36 2 Ends Open 1 Side/2 Ends Open All Ends & Sides Open 7500 0.37 0.31 0.25 0.29 8000 0.42 0.36 0.29 0.34 8500 0.48 0.41 0.34 0.39 9000 0.55 0.47 0.39 0.44 9500 0.62 0.53 0.45 0.51 10,000 0.70 0.60 0.51 0.57 10,500 0.78 0.68 0.58 0.65 11,000 0.87 0.76 0.65 0.72 11,500 0.97 0.85 0.73 0.81 12,000 1.08 0.94 0.82 0.9 12,500 1.19 1.04 0.91 0.99 13,000 1.30 1.15 1.00 1.10 13,500 1.43 1.26 1.10 1.20 14,000 1.56 1.38 1.20 1.31 14,500 1.69 1.50 1.31 1.43 15,000 1.84 1.63 1.43 1.56 CEILING DIFFUSER AIR THROW DATA - ft. 1 1 Effective Throw Range - ft. Air Volume cfm Step-Down Flush 9000 40 - 47 29 - 35 9500 43 - 50 33 - 41 10,000 46 - 54 37 - 46 10,500 50 - 58 42 - 51 11,000 53 - 61 46 - 56 11,500 55 - 64 50 - 61 12,000 58 - 67 54 - 66 12,500 61 - 71 58 - 71 13,000 64 - 74 62 - 75 13,500 67 - 77 66 - 79 Throw is the horizontal or vertical distance an airstream travels on leaving the outletor diffuser before the maximum velocity is reduced to 50 ft. per minute. Four sides open. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 25 ELECTRICAL DATA 20 TON 20 TON HIGH EFFICIENCY - VARIABLE AIR VOLUME (VAV) 1 Voltage - 60hz Compressor 1 Compressor 2 Compressor 3 Compressor 4 LGH242H4V 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph 13.5 8 5 Locked Rotor Amps 109 59 40 Rated Load Amps 13.5 8 5 Locked Rotor Amps 109 59 40 Rated Load Amps Rated Load Amps 13.5 8 5 Locked Rotor Amps 109 59 40 Rated Load Amps 13.5 8 5 Locked Rotor Amps 109 59 40 Outdoor Fan Motors (6) Full Load Amps 2.4 1.3 1 (14.4) (7.8) (6) Standard Power Exhaust (3) 0.33 HP Full Load Amps 2.4 1.3 1 (7.2) (3.9) (3) 50% High Static Power Exhaust (2) 2 HP Full Load Amps 7.5 3.4 2.7 (total) (15) (6.8) (5.4) 100% High Static Power Exhaust (3) 2 HP Full Load Amps 7.5 3.4 2.7 (22.5) (10.2) (8.1) 15 15 20 (total) (total) (total) Service Outlet 115V GFI (amps) Indoor Blower Motor 2 3 Maximum Overcurrent Protection Minimum Circuit Ampacity Horsepower 5 7.5 10 5 7.5 10 5 Full Load Amps 16.7 24.2 30.8 Unit Only 100 110 125 With (3) 0.33 HP Standard Power Exhaust 110 125 With 50% High Static Power Exhaust (2) 2 HP 110 With 100% High Static Power Exhaust (3) 2 HP 125 7.5 10 7.6 11 14 6.1 9 11 50 60 70 35 45 50 125 60 60 70 40 45 50 125 150 60 70 70 45 50 50 125 150 60 70 80 45 50 50 Unit Only 90 99 107 50 54 58 34 38 40 With (3) 0.33 HP Standard Power Exhaust 97 106 115 54 58 62 37 41 43 With 50% High Static Power Exhaust (2) 2 HP 105 114 122 57 61 65 40 43 46 With 100% High Static Power Exhaust (3) 2 HP 112 122 130 60 64 68 42 46 48 NOTE - All units have a minimum Short Circuit Current Rating (SCCR) of 5000 amps. 1 Extremes of operating range are plus and minus 10% of line voltage. 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 26 ELECTRICAL DATA 25 TON 25 TON HIGH EFFICIENCY - CONSTANT AIR VOLUME (CAV) 1 Voltage - 60hz Compressor 1 Compressor 2 Compressor 3 Compressor 4 Rated Load Amps LGH300H4B 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph 22.4 10.6 7.7 Locked Rotor Amps 149 75 54 Rated Load Amps 22.4 10.6 7.7 Locked Rotor Amps 149 75 54 Rated Load Amps 22.4 10.6 7.7 Locked Rotor Amps 149 75 54 Rated Load Amps 22.4 10.6 7.7 Locked Rotor Amps 149 75 54 Outdoor Fan Motors (6) Full Load Amps 2.4 1.3 1 (14.4) (7.8) (6) Standard Power Exhaust (3) 0.33 HP Full Load Amps 2.4 1.3 1 (7.2) (3.9) (3) 50% High Static Power Exhaust (2) 2 HP Full Load Amps 7.5 3.4 2.7 (total) (15) (6.8) (5.4) 100% High Static Power Exhaust (3) 2 HP Full Load Amps 7.5 3.4 2.7 (22.5) (10.2) (8.1) 15 15 20 (total) (total) (total) Service Outlet 115V GFI (amps) Indoor Blower Motor 2 3 Maximum Overcurrent Protection Minimum Circuit Ampacity Horsepower 5 7.5 10 5 7.5 10 5 Full Load Amps 16.7 24.2 30.8 Unit Only 150 150 150 With (3) 0.33 HP Standard Power Exhaust 150 150 With 50% High Static Power Exhaust (2) 2 HP 150 With 100% High Static Power Exhaust (3) 2 HP 7.5 10 7.6 11 14 6.1 9 11 70 70 80 50 50 60 150 70 70 80 60 60 60 150 175 70 80 80 60 60 60 150 175 175 80 80 90 60 60 60 Unit Only 127 135 143 61 64 68 45 49 51 With (3) 0.33 HP Standard Power Exhaust 128 134 142 62 65 68 46 48 52 With 50% High Static Power Exhaust (2) 2 HP 142 150 158 68 71 75 51 54 56 With 100% High Static Power Exhaust (3) 2 HP 149 157 165 71 75 78 53 57 59 NOTE - All units have a minimum Short Circuit Current Rating (SCCR) of 5000 amps. 1 Extremes of operating range are plus and minus 10% of line voltage. 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 27 ELECTRICAL DATA 25 TON 25 TON HIGH EFFICIENCY - VARIABLE AIR VOLUME (VAV) 1 Voltage - 60hz Compressor 1 Compressor 2 Compressor 3 Compressor 4 Rated Load Amps LGH300H4V 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph 22.4 10.6 7.7 Locked Rotor Amps 149 75 54 Rated Load Amps 22.4 10.6 7.7 Locked Rotor Amps 149 75 54 Rated Load Amps 22.4 10.6 7.7 Locked Rotor Amps 149 75 54 Rated Load Amps 22.4 10.6 7.7 Locked Rotor Amps 149 75 54 Outdoor Fan Motors (6) Full Load Amps 2.4 1.3 1 (14.4) (7.8) (6) Standard Power Exhaust (3) 0.33 HP Full Load Amps 2.4 1.3 1 (7.2) (3.9) (3) 50% High Static Power Exhaust (2) 2 HP Full Load Amps 7.5 3.4 2.7 (total) (15) (6.8) (5.4) 100% High Static Power Exhaust (3) 2 HP Full Load Amps 7.5 3.4 2.7 (22.5) (10.2) (8.1) 15 15 20 (total) (total) (total) Service Outlet 115V GFI (amps) Indoor Blower Motor 2 3 Maximum Overcurrent Protection Minimum Circuit Ampacity Horsepower 5 7.5 10 5 7.5 10 5 Full Load Amps 16.7 24.2 30.8 Unit Only 150 150 150 With (3) 0.33 HP Standard Power Exhaust 150 150 With 50% High Static Power Exhaust (2) 2 HP 150 With 100% High Static Power Exhaust (3) 2 HP 7.5 10 7.6 11 14 6.1 9 11 70 70 80 50 50 60 175 70 70 80 50 60 60 150 175 70 80 80 60 60 60 150 175 175 80 80 90 60 60 60 Unit Only 127 135 143 61 64 68 45 49 51 With (3) 0.33 HP Standard Power Exhaust 134 142 150 65 68 72 48 52 54 With 50% High Static Power Exhaust (2) 2 HP 142 150 158 68 71 75 51 54 56 With 100% High Static Power Exhaust (3) 2 HP 149 157 165 71 75 78 53 57 59 NOTE - All units have a minimum Short Circuit Current Rating (SCCR) of 5000 amps. 1 Extremes of operating range are plus and minus 10% of line voltage. 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 28 ELECTRICAL DATA 30 TON 30 TON HIGH EFFICIENCY - CONSTANT AIR VOLUME (CAV) 1 Voltage - 60hz Compressor 1 Compressor 2 Compressor 3 Compressor 4 LGH360H4B 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph Rated Load Amps 25 12.2 9 Locked Rotor Amps 164 100 78 Rated Load Amps 25 12.2 9 Locked Rotor Amps 164 100 78 Rated Load Amps 25 12.2 9 Locked Rotor Amps 164 100 78 Rated Load Amps 25 12.2 9 Locked Rotor Amps 164 100 78 Outdoor Fan Motors (6) Full Load Amps 2.4 1.3 1 (14.4) (7.8) (6) Standard Power Exhaust (3) 0.33 HP Full Load Amps 2.4 1.3 1 (7.2) (3.9) (3) 50% High Static Power Exhaust (2) 2 HP Full Load Amps 7.5 3.4 2.7 (total) (15) (6.8) (5.4) 100% High Static Power Exhaust (3) 2 HP Full Load Amps 7.5 3.4 2.7 (22.5) (10.2) (8.1) 15 15 20 (total) (total) (total) Service Outlet 115V GFI (amps) Indoor Blower Motor 2 3 Maximum Overcurrent Protection Minimum Circuit Ampacity Horsepower 5 7.5 10 5 7.5 10 5 Full Load Amps 16.7 24.2 30.8 Unit Only 150 150 175 With (3) 0.33 HP Standard Power Exhaust 150 175 With 50% High Static Power Exhaust (2) 2 HP 175 With 100% High Static Power Exhaust (3) 2 HP 7.5 10 7.6 11 14 6.1 9 11 70 80 80 60 60 60 175 80 80 90 60 60 60 175 175 80 80 90 60 60 70 175 175 200 80 90 90 60 70 70 Unit Only 138 145 153 68 71 75 51 54 56 With (3) 0.33 HP Standard Power Exhaust 145 153 161 72 75 78 54 57 59 With 50% High Static Power Exhaust (2) 2 HP 153 160 168 75 78 81 56 59 62 With 100% High Static Power Exhaust (3) 2 HP 160 168 176 78 81 85 59 62 64 NOTE - All units have a minimum Short Circuit Current Rating (SCCR) of 5000 amps. 1 Extremes of operating range are plus and minus 10% of line voltage. 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 29 ELECTRICAL DATA 30 TON 30 TON HIGH EFFICIENCY - VARIABLE AIR VOLUME (VAV) 1 Voltage - 60hz Compressor 1 Compressor 2 Compressor 3 Compressor 4 LGH360H4V 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph Rated Load Amps 25 12.2 9 Locked Rotor Amps 164 100 78 Rated Load Amps 25 12.2 9 Locked Rotor Amps 164 100 78 Rated Load Amps 25 12.2 9 Locked Rotor Amps 164 100 78 Rated Load Amps 25 12.2 9 Locked Rotor Amps 164 100 78 Outdoor Fan Motors (6) Full Load Amps 2.4 1.3 1 (14.4) (7.8) (6) Standard Power Exhaust (3) 0.33 HP Full Load Amps 2.4 1.3 1 (7.2) (3.9) (3) 7.5 3.4 2.7 (15) (6.8) (5.4) 7.5 3.4 2.7 (22.5) (10.2) (8.1) 15 15 20 (total) (total) 50% High Static Power Exhaust (2) 2 HP 100% High Static Power Exhaust (3) 2 HP Service Outlet 115V GFI (amps) Indoor Blower Motor 2 3 Maximum Overcurrent Protection Minimum Circuit Ampacity Horsepower 5 7.5 10 5 7.5 10 5 Full Load Amps 16.7 24.2 30.8 Unit Only 150 150 175 With (3) 0.33 HP Standard Power Exhaust 150 175 With 50% High Static Power Exhaust (2) 2 HP 175 With 100% High Static Power Exhaust (3) 2 HP 7.5 10 7.6 11 14 6.1 9 11 70 80 80 60 60 60 175 80 80 90 60 60 60 175 175 80 80 90 60 60 70 175 175 200 80 90 90 60 70 70 Unit Only 138 145 153 68 71 75 51 54 56 With (3) 0.33 HP Standard Power Exhaust 145 153 161 72 75 78 54 57 59 With 50% High Static Power Exhaust (2) 2 HP 153 160 168 75 78 81 56 59 62 With 100% High Static Power Exhaust (3) 2 HP 160 168 176 78 81 85 59 62 64 NOTE - All units have a minimum Short Circuit Current Rating (SCCR) of 5000 amps. 1 Extremes of operating range are plus and minus 10% of line voltage. 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 30 ELECTRICAL ACCESSORIES 20 TON HIGH EFFICIENCY LGH242H4 Voltage - 60hz - 3 phase 208/230V Indoor Blower Motor Horsepower 460V 575V 5 7.5 10 5 7.5 10 5 7.5 10 Unit Only 54W86 54W86 54W86 54W85 54W85 54W85 54W85 54W85 54W85 Unit + Standard Power Exhaust (3) 0.33 HP 54W86 54W86 54W86 54W85 54W85 54W85 54W85 54W85 54W85 Unit + 50% High Static Power Exhaust (2) 2 HP 54W86 54W86 54W86 54W85 54W85 54W85 54W85 54W85 54W85 Unit + 100% High Static Power Exhaust (3) 2 HP 54W86 54W86 54W86 54W85 54W85 54W85 54W85 54W85 54W85 30K75 30K75 30K75 30K75 30K75 30K75 30K75 30K75 30K75 Disconnect Terminal Block 25 TON HIGH EFFICIENCY LGH300H4 Voltage - 60hz - 3 phase 208/230V Indoor Blower Motor Horsepower 460V 575V 5 7.5 10 5 7.5 10 5 7.5 10 Unit Only 54W86 54W86 54W87 54W85 54W85 54W85 54W85 54W85 54W85 Unit + Standard Power Exhaust (3) 0.33 HP 54W86 54W87 54W87 54W85 54W85 54W85 54W85 54W85 54W85 Unit + 50% High Static Power Exhaust (2) 2 HP 54W87 54W87 54W87 54W85 54W85 54W86 54W85 54W85 54W85 Unit + 100% High Static Power Exhaust (3) 2 HP 54W7 54W87 54W87 54W85 54W86 54W86 54W85 54W85 54W85 30K75 30K75 30K75 30K75 30K75 30K75 30K75 30K75 30K75 Disconnect Terminal Block 30 TON HIGH EFFICIENCY LGH360H4 Voltage - 60hz - 3 phase 208/230V Indoor Blower Motor Horsepower Disconnect Terminal Block 460V 575V 5 7.5 10 5 7.5 10 5 7.5 10 Unit Only 54W87 54W87 54W87 54W85 54W85 54W86 54W85 54W85 54W85 Unit + Standard Power Exhaust (3) 0.33 HP 54W87 54W87 54W87 54W85 54W86 54W86 54W85 54W85 54W85 Unit + 50% High Static Power Exhaust (2) 2 HP 54W87 54W87 54W87 54W86 54W86 54W86 54W85 54W85 54W85 Unit + 100% High Static Power Exhaust (3) 2 HP 54W87 54W87 54W87 54W86 54W86 54W86 54W85 54W85 54W85 30K75 30K75 30K75 30K75 30K75 30K75 30K75 30K75 30K75 E-Series Packaged Gas / Electric 20 to 30 Ton / Page 31 UNIT CLEARANCES - INCHES (MM) Unit With Economizer C OUTDOOR AIR HOOD D B A 1 Unit Clearance Service Clearance A B C D in. mm in. mm in. mm in. mm 60 1524 36 914 36 914 66 1676 Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 45 1143 36 914 36 914 41 1041 Top Clearance Unobstructed NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. 1 S ervice Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. Unit With High Static Power Exhaust Fans C OUTDOOR AIR HOOD D B A 1 Unit Clearance A B C D in. mm in. mm in. mm in. mm Service Clearance 60 1524 36 914 80 2032 66 1676 Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 45 1143 36 914 80 2032 41 1041 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. 1 S ervice Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 32 Top Clearance Unobstructed UNIT CLEARANCES - INCHES (MM) Unit With Horizontal Barometric Relief Dampers OPTIONAL BAROMETRIC RELIEF EXHAUST DAMPERS (Field Installed on Return Air Duct) NOTE Allow adequate clearance for duct and barometric relief damper installation. NOTE Dampers may be installed on each side of return air duct or end to end on one side of return air duct. OUTDOOR AIR HOOD C B A 1 Unit Clearance A B C in. mm in. mm in. mm Service Clearance 60 1524 36 914 66 1676 Clearance to Combustibles 36 914 1 25 1 25 Minimum Operation Clearance 45 1143 36 914 41 1041 Top Clearance Unobstructed NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. 1 S ervice Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 33 OUTDOOR SOUND DATA Unit Model Number 242, 300, 360 Octave Band Sound Power Levels dBA, re 10-12 Watts Center Frequency - HZ 1 125 250 500 1000 2000 4000 8000 Sound Rating Number (dB) 84 85 90 90 85 80 72 95 Note - The octave sound power data does not include tonal corrections. 1 Sound Rating Number according to AHRI Standard 370-2001. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 34 WEIGHT DATA Model Number Net Shipping lbs. kg lbs. kg 242 Base Unit 3107 1435 3317 1505 242 Max. Unit 3485 1581 3695 1676 300 Base Unit 3107 1435 3317 1505 300 Max. Unit 3485 1581 3695 1676 360 Base Unit 3107 1435 3317 1505 360 Max. Unit 3485 1581 3695 1676 OPTIONS / ACCESSORIES Description CEILING DIFFUSERS Step-Down LARTD30/36 Flush LAFD30/36 Transitions LASRT30/36 ECONOMIZER / OUTDOOR AIR / EXHAUST Economizer E1ECON15D-1 Barometric Relief Downflow Barometric Relief Dampers E1DAMP60D-1 Horizontal Barometric Relief Dampers LAGEDH30/36 Outdoor Air Dampers Damper Section (downflow) Motorized - E1DAMP25D-1Damper Section (downflow) Manual - E1DAMO15D-1Outdoor Air Hood (downflow) LAOAH30/36 Power Exhaust Standard Static - E1PWRE40D 50% High Static - LAPEB30/36 100% High Static with or without VFD - LAPEB30/36 or LAPEV30/36 GAS HEAT EXCHANGER (NET WEIGHT) Medium Heat (adder over standard heat) High Heat (adder over standard heat) PACKAGING LTL Packaging (less than truck load) ROOF CURBS - CLIP CURB Downflow 14 in. height LARMF30/36S-14 18 in. height LARMF30/36S-18 24 in. height LARMF30/36S-24 Horizontal 30 in. height LARMFH30/36S-30 41 in. height LARMFH30/36S-41 ROOF CURBS - STANDARD Downflow 14 in. height LARMF18/36-14 24 in. height LARMF18/36-24 Downflow - Full Perimeter 14 in. height S6CURB1012124 in. height S6CURB11121Horizontal 30 in. height LARMFH30/36-30 41 in. height LARMFH30/36-41 Shipping Weight lbs. kg 437 414 85 198 188 39 119 54 45 20 20 9 72 68 76 33 31 34 99 460 525 45 209 238 18 64 8 29 300 136 149 204 248 68 93 112 456 480 207 218 160 220 73 100 180 248 82 112 445 725 202 329 E-Series Packaged Gas / Electric 20 to 30 Ton / Page 35 DIMENSIONS - INCHES (MM) CORNER WEIGHTS Model No. LGH242 Base Unit LGH242 Max. Unit LGH300 Base Unit LGH300 Max. Unit LGH360 Base Unit LGH360 Max. Unit AA lbs. 632 709 632 709 632 709 BB kg 287 322 287 322 287 322 lbs. 635 712 635 712 635 712 CC kg 288 323 288 323 288 323 lbs. 912 1023 912 1023 912 1023 CENTER OF GRAVITY EE FF in. mm in. mm 60 1524 37 940 60 1524 37 940 60 1524 37 940 60 1524 37 940 60 1524 37 940 60 1524 37 940 DD kg 414 464 414 464 414 464 lbs. 928 1041 928 1041 928 1041 kg 421 472 421 472 421 472 Base Unit - The unit with NO INTERNAL OPTIONS. Max. Unit - The unit with ALL INTERNAL OPTIONS Installed. (Economizer, Standard Static Power Exhaust Fans, Controls, etc.). Does not include accessories external to unit or high static power exhaust. EE 4-1/4 (108) AA 5-3/4 (146) 15 (381) 78-1/2 (1994) 18 (457) 17-1/2 (445) BB BOTTOM RETURN AIR OPENING CENTER OF GRAVITY 28 28 (711) (711) 4-1/2 20 (508) 20 (508) (114) FF BOTTOM SUPPLY AIR OPENINGS 4 (102) DD CC BOTTOM POWER/GAS ENTRY 5 X 8 inches (127 X 203 mm) TOP VIEW 9 (229) OPTIONAL 115 VOLT OUTLET (Factory Installed Inside Unit) 90-1/8 (2289) 145 (3683) OPTIONAL DISCONNECT (Factory Installed) 65 (1651) SIDE ELECTRICAL INLETS 61-3/4 (1568) CONDENSATE DRAIN 90−3/4 (2305) END VIEW E-Series Packaged Gas / Electric 20 to 30 Ton / Page 36 FLUE OUTLET OPTIONAL OUTDOOR GRILLE KIT (Field Installed) (Both Sides) 5-3/4 (146) 5-3/8 (137) 31-1/2 (800) GAS SUPPLY INLET (For Bottom Gas Supply Only) 3-1/4 (83) 4 (102) FORKLIFT SLOTS (Front and Left Side Only) 119−3/4 (3042) SIDE VIEW LIFTING HOLES (For Rigging Front and Back) 25-3/4 (654) ACCESSORY DIMENSIONS - INCHES (MM) OPTIONAL OUTDOOR AIR HOOD DETAIL WITH STANDARD STATIC POWER EXHAUST FANS 25−1/2 (648) OPTIONAL OUTDOOR AIR HOOD (Factory or Field Installed) Required with Economizer or Outdoor Air Damper 1 OPTIONAL STANDARD STATIC POWER EXHAUST FANS HOOD (Field Installed) 1 Field Installed in Return Air Duct for Horizontal Applications. OPTIONAL HIGH STATIC POWER EXHAUST FANS DETAIL 41−3/4 (1060) OPTIONAL HIGH STATIC POWER EXHAUST FANS (Field Installed) HORIZONTAL BAROMETRIC RELIEF DAMPERS (Field installed in horizontal return air duct adjacent to unit) 54−1/2 (1384) 52−1/2 (1334) 6-1/2 (165) FRONT VIEW SIDE VIEW 1 14-1/2 (368) 1 13 (330) NOTE − Two furnished per order no. 1 NOTE − Opening size required in return air duct. E-Series Packaged Gas / Electric 20 to 30 Ton / Page 37 ACCESSORY DIMENSIONS - INCHES (MM) CLIP CURBS - DOUBLE DUCT OPENING 1-13/16 (46) 1-13/16 (46) 1-3/4 (44) 16 (406) 86-1/4 (2191) 81-1/2 (2070) 82-5/8 (2099) 17 (432) 21 (533) CURB RETURN AIR OPENING 13-1/4 (337) 79-1/2 (2019) 110-1/2 (2807) 115-1/8 (2594) 14 (356) 18 (457) 24 (610) CURB SUPPLY AIR OPENING 61-1/2 (1562) TYPICAL FLASHING DETAIL FOR ROOF CURB BASE BOTTOM DETAIL ROOF CURB 1-13/16 (46) PACKAGED UNIT 1/2 (13) FIBERGLASS INSULATION (Furnished) COUNTER FLASHING (Field Supplied) FACTORY INSTALLED PERIMETER WOOD NAILER STRIP NAILER STRIP (Furnished) ROOF CURB (Extends around entire perimeter of unit) CANT STRIP (Field Supplied) ROOFING MATERIAL 14 (356) 18 (457) 24 (610) RIGID INSULATION (Field Supplied) 1-13/16 (46) E-Series Packaged Gas / Electric 20 to 30 Ton / Page 38 ACCESSORY DIMENSIONS - INCHES (MM) STANDARD ROOF CURBS - DOUBLE DUCT OPENING 1-13/16 (46) 1-3/4 (44) 16 (406) 82-5/8 (2099) 86-1/4 (2191) 17 (432) 79-1/2 (2019) 21 (533) 98-1/2 (2502) CURB RETURN AIR OPENING 1-13/16 (46) 13-1/4 (337) 102-1/8 (2594) CURB SUPPLY AIR OPENING 14 (356) or 24 (610) 61-1/2 (1562) 3/4 (19) Typ. TYPICAL FLASHING DETAIL FOR ROOF CURB BASE BOTTOM DETAIL ROOF CURB 1-13/16 (46) PACKAGED UNIT 1 (25) FIBERGLASS INSULATION (Furnished) COUNTER FLASHING (Field Supplied) FACTORY INSTALLED PERIMETER WOOD NAILER STRIP NAILER STRIP (Furnished) ROOF CURB (Extends around entire perimeter of unit) CANT STRIP (Field Supplied) ROOFING MATERIAL 14 (356) 24 (610) RIGID INSULATION (Field Supplied) 2 (51) E-Series Packaged Gas / Electric 20 to 30 Ton / Page 39 ACCESSORY DIMENSIONS - INCHES (MM) STANDARD ROOF CURBS - FULL PERIMETER - DOUBLE DUCT OPENING 1-13/16 (46) 1-3/4 (44) 16 (406) 82-5/8 (2099) 86-1/4 (2191) 17 (432) 79-1/2 (2019) 21 (533) 111-1/2 (2832) CURB RETURN AIR OPENING 1-13/16 (46) 115-1/8 (2924) 13-1/4 (337) CURB SUPPLY AIR OPENING 14 (356) or 24 (610) 61-1/2 (1562) 3/4 (19) Typ. TYPICAL FLASHING DETAIL FOR ROOF CURB BASE BOTTOM DETAIL ROOF CURB 1-13/16 (46) PACKAGED UNIT 1 (25) FIBERGLASS INSULATION (Furnished) COUNTER FLASHING (Field Supplied) FACTORY INSTALLED PERIMETER WOOD NAILER STRIP NAILER STRIP (Furnished) ROOF CURB (Extends around entire perimeter of unit) CANT STRIP (Field Supplied) ROOFING MATERIAL 14 (356) 24 (610) RIGID INSULATION (Field Supplied) 2 (51) E-Series Packaged Gas / Electric 20 to 30 Ton / Page 40 ACCESSORY DIMENSIONS - INCHES (MM) ROOF CURBS WITH SUPPLY & RETURN AIR TRANSITIONS FOR CEILING DIFFUSERS 80-3/4 (2051) 60 (1524) 4-1/2 (114) 60 (1524) SUPPLY AIR OPENINGS 28 (711) LASRT RETURN TRANSITION 28 (711) SUPPORT ANGLE (Furnished with Transitions) 54 (1372) LASRT SUPPLY TRANSITION RETURN AIR OPENING A A TRANSITION DETAIL 1-1/2 (38) Typ. 12 14 (356) (305) 2 (51) 3/4 Typ. (19) 26-1/2 (673) 26-1/2 (673) LASRT SUPPLY TRANSITION LASRT RETURN TRANSITION 28 (711) 4-1/2 (114) 28 (711) SECTION B-B TOP VIEW E-Series Packaged Gas / Electric 20 to 30 Ton / Page 41 ACCESSORY DIMENSIONS - INCHES (MM) HORIZONTAL ROOF CURBS − Requires Optional Horizontal Return Air Panel Kit 102-1/8 (2594) 1-13/16 (46) 1-13/16 (46) 98-1/2 (2502) Frame Opening NOTE LARMFH30/36-30 is designed for horizontal discharge when unit is mounted on a slab. LARMFH30/36-41 is designed for horizontal discharge when unit is mounted on a rooftop. 1-13/16 (46) Frame 30 (762) 41 (1041) Opening 1 2 1 (25) NAILER STRIP (Furnished) 2 (51) A A SECTION A-A 82-5/8 (2099) PANEL TO COVER RETURN AIR OPENING IN BOTTOM OF UNIT (Furnished With Optional Horizontal Return Air Panel Kit) 98-1/2 (2502) 86-1/4 (2191) SUPPLY AIR TURNING VANE (Furnished) 54 (1372) SIDE VIEW NOTE − Roof deck may be omitted within confines of curb. (PACKAGED UNIT) 1-13/16 (46) TOP VIEW 1,2 NAILER STRIP (Furnished) 13-1/4 (337) 102-1/8 (2594) 86-1/4 (2191) 5-1/2 (140) 1 2 30 (762) 41 (1041) 75 (1905) CURB SUPPLY AIR OPENING With 1-1/2 in. (38 mm) FLANGE 1, 2 18 1 2 SUPPLY AIR TURNING VANE (Furnished) (457) 6-1/2 (165) 17-1/2 (445) 102-1/2 (2604) 86-5/8 (2200) FRONT VIEW 1 SUPPLY DUCT PANELS (Furnished) SIDE VIEW LARMFH30/36-30 2 LARMFH30/36-41 HORIZONTAL SUPPLY AND RETURN AIR OPENINGS ROOFTOP UNIT WITH HORIZONTAL ROOF CURB OPTIONAL RETURN AIR PANEL KIT (Required For Horizontal Applications) 65 (1651) 91 (2311) LARMFH30/36-30 102 (2591) LARMFH30/36-41 78-1/2 (1994) 15 (381) HORIZONTAL RETURN AIR OPENING 2 (51) 1 26 (660) LARMFH30/36-30 1 37 (940) LARMFH30/36-41 1 NOTE − Top of Curb extends 4 inch (102 mm) inside bottom of unit base. See Typical Flashing Detail. 75 (1905) HORIZONTAL SUPPLY AIR OPENING 42-7/8 (1089) HORIZONTAL ROOF CURB (Required For Horizontal Applications) SIDE VIEW (Horizontal Openings) E-Series Packaged Gas / Electric 20 to 30 Ton / Page 42 18 (457) 5-1/4 (133) 13-1/4 (337) 6-1/2 (165) LARMFH30/36-30 17-1/2 (445) LARMFH30/36-41 ACCESSORY DIMENSIONS - INCHES (MM) COMBINATION CEILING SUPPLY AND RETURN DIFFUSERS STEP-DOWN CEILING DIFFUSER F E G H G FLUSH CEILING DIFFUSER F E D J K G H G D J K C C 2 (51) 2 (51) N B B M L Model Number A in. mm B in. mm C in. mm D in. mm E F G H J K in. 65-5/8 40-1/2 63-1/2 114 in. 28 mm 711 1-1/2 mm 38 in. 60 mm 1524 in. 1-3/4 in. in. in. in. mm 1613 in. in. mm D in. mm E F G H in. 65-5/8 1667 65-5/8 1667 40 1016 63-1/2 1613 63-1/2 mm 1613 in. 4-1/4 mm 108 in. 28 mm 711 in. 1-5/8 mm 32 J in. 60 mm 1524 K in. 1-3/4 44 63-1/2 in. mm C 1613 4-1/2 in. B 1029 63-1/2 LAFD30/36 mm 1667 mm mm Duct Size A 1667 in. mm N Model Number 65-5/8 1613 mm M LARTD30/36 mm mm L A A mm Duct Size in. mm 44 28 x 60 711 x 1524 63-1/2 1613 12-1/8 308 28 x 60 711 x 1524 E-Series Packaged Gas / Electric 20 to 30 Ton / Page 43 Visit us at www.allied-commercial.com For the latest technical information, visit us at www.allied-commercial.com Contact us at 1-800-738-4000 NOTE - Due to Allied Commercial ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2012 Allied Air Enterprises LLC, a Lennox International Inc. Company
Similar documents
10.5 to 26.4 kW - LennoxPROs.com
• S maller internal volume (reduced refrigerant charge). • H igh durability (all aluminum construction). • Fewer brazed joints. • C ompact design (reduces unit weight). • Easy maintenance/c...
More informationE-Series Rooftop Units
Dehumidification System Option - Patented system allows for independent control of temperature and humidity, providing enhanced comfort control. MERV 13 Filters - Available as factory or field opti...
More information