Stud and Track - Insulation Express
Transcription
Stud and Track - Insulation Express
Partitioning Systems Stud & Track Note: electrical wires should be protected where passing through framework Track C Stud Snipped and folded to form header Light Switch Partitioning Systems Stud & Track Partition Brace 4 An economical friction-fit system to assemble frames for strong, compact, lightweight non loadbearing partitions, Metal stud partitioning is ideal for use in domestic and commercial Benefits situations, for heights up to 12m ɀ Quick to erect, lightweight and clean and a wide range of partition ɀ Metal Stud is dimensionally accurate thicknesses. When installing, ensure that electrical cables that pass through floor or ceiling are protected by grommets when installing studs. and will not twist or bow ɀ Range of stud widths – 48mm, 50mm, 60mm, 70mm, 92mm and 146mm to meet different performance requirements ɀ Services are easy to install For speedy, accurate installation ɀ Mineral wool can easily be installed to uprate sound insulation the use of an electrically or ɀ Easy to cut to length using tin snips battery operated screw gun is ɀ Frames easily fit together recommended. ɀ Door frames simply formed Partitioning Systems Stud & Track Track Product Description Standard Track 25 50mm Standard Track (25mm leg) x 0.5mm 52mm Standard Track (25mm leg) x 0.5mm 62mm Standard Track (25mm leg) x 0.5mm 72mm Standard Track (25mm leg) x 0.5mm Stock Lengths Metre 3.000 3.000 3.000 3.000 Weight per Length Kgs 1.13 1.15 1.25 1.41 Stock Lengths Metre 3.000 3.000 3.000 3.000 3.000 Weight per Length Kgs 1.32 1.42 1.55 1.81 2.40 Stock Lengths Metre 3.000 3.000 3.000 3.000 3.000 Weight per Length Kgs 1.74 1.86 1.98 3.13 2.83 Stock Lengths Metre 3.000 3.000 3.000 Weight per Length Kgs 3.43 3.79 4.68 32mm Leg Track 32 Available in 52, 72, 94 or 148 wide 52mm Track (32mm leg) x 0.5mm 62mm Track (32mm leg) x 0.5mm 72mm Track (32mm leg) x 0.5mm 94mm Track (32mm leg) x 0.5mm 148mm Track (32mm leg) x 0.5mm Product Description Deep Track 50 52mm Deep Track (50mm leg) x 0.5mm 62mm Deep Track (50mm leg) x 0.5mm 72mm Deep Track (50mm leg) x 0.5mm 94mm Deep Track (50mm leg) x 0.7mm 148mm Deep Track (50mm leg) x 0.5mm Product Description Available in 52, 62, 72, 94 or 148 wide 72mm Extra Deep Track (70mm leg) x 0.7mm 94mm Extra Deep Track (70mm leg) x 0.7mm 148mm Extra Deep Track (70mm leg) x 0.7mm Extra Deep Track 70 Available in 72, 94 or 148 wide Partitioning Systems Product Description Stud & Track Available in 50, 52, 62 or 72 wide 5 Partitioning Systems Stud & Track Standard C Stud Service Holes All C and I studs are manufactured with 3 service holes to allow electrical cables and pipes to run through the partition. Product Description Service hole positions are: 48mm C Stud x 0.5mm, Flange dimensions 32/34mm Hole 1 – 300mm from end to centre of hole Hole 2 – 900mm from end to centre of hole Hole 3 – 1500mm from end to centre of hole 50mm C Stud x 0.5mm, Flange dimensions 32/34mm All C Studs have rectangular service holes 32mm wide x 75mm long. Standard C Stud 6.5 6.5 32 60mm C Stud x 0.5mm, Flange dimensions 32/34mm 34 70mm C Stud x 0.5mm, Flange dimensions 32/34mm Available in 48, 50, 60, 70, 92 or 146 wide 92mm C Stud x 0.5mm, Flange dimensions 32/34mm 146mm C Stud x 0.5mm, Flange dimensions 32/34mm Heavy Duty C Stud 6.5 6.5 32 Product Description 70mm Heavy Duty C Stud x 0.7mm, Flange dimensions 32/34mm 146mm Heavy Duty C Stud x 0.7mm, Flange dimensions 32/34mm Available in 70 or 146 wide Stud & Track Product Description Partitioning Systems Stock Lengths Metre 3.600 4.200 3.600 4.200 Weight per Length Kgs 2.82 3.29 4.32 5.04 Stock Lengths Metre 2.700 3.000 3.600 3.600 4.200 3.600 4.200 3.600 5.000 6.000 3.600 5.000 6.000 Weight per Length Kgs 2.01 2.24 2.69 2.82 3.30 3.56 4.15 4.59 6.37 7.65 5.65 7.86 9.43 I Stud I Stud 6 Weight per Length Kgs 1.14 1.29 1.31 1.58 1.17 1.35 1.46 1.75 1.26 1.46 1.58 1.89 1.37 1.53 1.71 2.05 2.39 2.30 2.68 3.13 3.65 4.33 5.21 Heavy Duty C Stud 34 38 50mm I Stud x 0.6mm, Flange dimensions 38mm 60mm I Stud x 0.6mm, Flange dimensions 38mm 70mm I Stud x 0.7mm, Flange dimensions 38mm 92mm I Stud x 0.9mm, Flange dimensions 38mm Available in 50, 60, 70, 92 or 146 wide Flat Bracing Strip Stock Lengths Metre 2.400 2.700 3.000 3.600 2.400 2.700 3.000 3.600 2.400 2.700 3.000 3.600 2.400 2.700 3.000 3.600 4.200 3.600 4.200 3.600 4.200 5.000 6.600 146mm I Stud x 0.9mm, Flange dimensions 38mm 0.6 70 Bracing Strap & Partition Brace Product Description Partition Brace 10 Flat Bracing Strip 70 x 0.7mm Stock Lengths Weight per Length Metre Kgs 2.400 0.80 Partition Brace 70 x 10 x 0.7mm 2.400 70 1.08 Partitioning Systems Stud & Track Spliced Studs Overheight Partition In order to extend them, single C Studs can be easily spliced together. Be sure to overlap the C Studs at least 600mm and fix them together with steel pop rivets, stud interlocking tool or wafer head screws on both flanges. Partition Brace – due to the unique design of this product, the lips are simply snipped out where the partition brace overlaps the stud. Slots are pierced to allow for studs to be erected at 400 or 600mm centres. Partition Brace to provide support for horizontal board edges and fire protection* * Must be used to support fire certification C Studs with min 600mm overlap Steel pop rivets or wafer head screws at 150mm centres on both flanges Door Frame construction showing timber lining Boxed Studs To create greater rigidity and Track height and to provide support at doorways, C Studs may be 150mm minimum boxed together. To enable this the bearing faces of the C Studs are simply nest short and long faces alternately and snap together. Track fixed horizontally between studs End stud fixed to track Timber sub frame Timber door frame Studs fixed to floor and ceiling tracks Door jamb details shown on Page 54 Track Partitioning Systems Stud & Track asymmetrical – 32mm and 34mm – 7 Solutions for Residential Applications Speedline ‘Space Saver’ Partitioning Systems Partitions Using Resilient Bar Resilient Bar Resilient Bar 45 Product Description Stock Lengths Weight per Length Metre Kgs 3.000 1.05 Resilient Bar x 0.5mm 17 Resilient Bar Partitions using Resilient Bar 70mm C Stud spaced at 600mm centres with Resilient Bar fixed perpendicular to the studs one side only at 600mm centres. Two layers of 15mm Fire Resistant plasterboard. 50mm glass mineral wool. 70mm C Stud spaced at 600mm centres with Resilient Bar fixed perpendicular to the studs one side only at 600mm centres. Inner layer of 19mm plank, outer layer of 12.5mm Standard plasterboard. 50mm glass mineral wool. 70mm C Stud spaced at 600mm centres with Resilient Bar fixed perpendicular to the studs on both sides at 600mm centres. Two layers of 15mm Sound Resistant plasterboard. 50mm glass mineral wool. 70mm C Stud with Resilient Bar one side only clad with inner layer of 15mm Sound Resistant Plasterboard and outer layer of 12.5mm Impact Resistant Plasterboard infilled with 50mm Glass Mineral Wool. 70mm C Stud with Resilient Bar both sides only clad with inner layer of 15mm Sound Resistant Plasterboard and outer layer of 12.5mm Impact Resistant Plasterboard infilled with 50mm Glass Mineral Wool. Stud Width mm 70 70 70 70 70 70 70 Partition Grade BS5234 SD SD SD SD SD SD SD Max Height m 4.2 4.2 4.2 4.0 3.3 4.1 3.3 Nom Weight 2 kg/m 53 51 49 51 54 52 53 Nom Width mm 147 147 150 142 164 142 159 Fire Resistance min 90 120 60 60 90 90 90 Sound Insulation RwdB 61 62 63 59 63 58 60 Test Reference RB001 RB002 RB003 RB004 RB005 RB006 RB007 be fixed to timber or metal studs, the following centres apply. For single layer boarding, fix Resilient Bar at 400mm centres. For double layer boarding, fix Resilient Bar at 600mm centres. Fix the initial Resilient Bar 50mm down from the ceiling and the last bar 50mm from the floor. Screw fix the Resilient Bars to the Studs using Wafer head Self-Tapping Screws. Screw fix the wallboard to the Resilient Bar only, ensuring the screw does not touch the metal substrate. Bars are joined by putting together on the stud. ɀ Reduced overall construction nominal width Partitioning Systems Stud & Track ɀ Pre-completion testing needed 8 ɀ Part E requirements: New Build 45dB Dntw + Ctr Refurbishments 43dB Dntw + Ctr Refer to chart for plasterboard configurations. Resilient bars at 400mm or 600mm horizontal centres C Stud Glass mineral wool Timber sole plate if required on uneven floors Track 70mm C Stud spaced at 600mm centres with Resilient Bar fixed perpendicular to the studs one side only at 600mm centres. Two layers of 12.5mm Sound Resistant plasterboard. 50mm glass mineral wool. 70mm C Stud spaced at 600mm centres with Resilient Bar fixed perpendicular to the studs one side only at 600mm centres. Two layers of 15mm Sound Resistant plasterboard. 50mm glass mineral wool. Where Speedline Resilient Bar is to All sound insulation data is based on laboratory evaluation of the building element in isolation and cannot reproduce your installed local conditions. The actual tests carried out are used to offer an order of magnitude comparison for the performance of the various systems. Sound insulation on site is a function of the partition chosen and the associated structures in which it is installed. Speedline cannot take any responsibility for overall design and would advise that specialist advice is sought at an early stage of design. All test data and system specifications are for systems constructed with materials and components as shown. The inclusion of other components without prior approval or constructed on site contrary to these documents will invalidate test certification and system performance. Solutions for Residential Applications Partitioning Systems Separating Wall Twin Frame EWS-1 All sketches show one layer of Double board mineral wool batts placed between the studs. It is also acceptable to Partition brace place a layer of mineral wool batts or quilt on both sides of the wall. This system complies with Robust Track Details Ltd for Part E of the Building Regulations. Pre-Completion Testing is still required for Robust Detail solutions unless the site is registered with Robust Details Ltd. All systems have a maximum 3000m height. Benefits ɀ 60 minutes fire resistance ɀ 45 DnT, w + Ctr dB airborne sound onsite Inner layer of plasterboard Wall Lining Most Common Builds: – two layers 12.5mm Sound Resistant plasterboard, subject to board having combined mass Mineral wool cavity as required Pairs of C Studs, braced at mid-height with partition brace or acoustic brackets Timber sole plate if required on uneven floors Min 200mm plasterboard outer leaf and 19mm plank inner leaf (mounted horizontally). Subject to combined mass of 22 kg/m2. – two or more layers of gypsumbased board minimum (total nominal mass per unit area 22 kg/m2) both sides. – all joints staggered. Wall Width 200mm (min) between inner faces of wall linings. Absorbent Material Do – one layer 50mm (min) unfaced ɀ Keep wall linings at least mineral wool batts (density 33-60 kg/m ), or 3 200mm apart ɀ Ensure the batts cover whole wall area and are fitted together tightly – two layers 25mm (min) unfaced mineral wool batts (density 33-60 kg/m3), or – two layers 25mm (min) unfaced mineral wool quilt (density min 10 kg/m3). – refer to robust details specification for checklists snd construction details. ɀ Make sure batts are not tightly compressed by the twin frames ɀ Ensure that all cavity stops/closers are flexible or are fixed to one frame only ɀ Make sure there is no connection between the two leaves except where ties are necessary for structural reasons ɀ Stagger joints in wall linings to avoid air paths ɀ Seal all joints in outer layer with tape or caulk with sealant Partitioning Systems – 12.5mm Sound Resistant Stud & Track of 22 kg/m2, or 9 Partitioning Systems Stud & Track Product Performance Guide the appropriate length screw. The second layer of plasterboard should be fixed with all joints staggered in relation to the first layer. Fixing of Floor and Ceiling Tracks All tracks must be secured to the floor and ceiling in the centre of the profile at 600mm centres with suitable fixings. For 94mm and 148mm tracks, two rows of staggered fixings at 600mm centres are recommended. Partition Brace For fixing of Partition Brace or for joining stud to track (if required) the use of wafer head screws is recommended. Plasterboard Fixing Centres For all partitions i.e. C Studs, I Studs, Resilient Bar, Wall Liner and Wall Furring the following applies:Single Layer Installations Plasterboard must be fixed at 300mm maximum centres to the metal framework with the appropriate length screw. Plasterboard joints must be staggered from one side of the partition to the other. Double Layer Installations Inner layers can be fixed at 600mm centres but outer layers must be fixed at 300mm centres to the metal framework with Partitioning Systems Stud & Track 48mm and 50mm C Stud spaced at 600mm centres 10 Part Grade Max Height Nominal Weight BS 5234 m Kg/m 2 MD MD MD HD MD MD MD HD HD HD SD SD SD SD SD SD SD SD MD SD SD 2.5 2.8 2.5 2.8 2.5 2.5 2.5 2.5 2.8 2.8 3.4 3.4 3.4 3.7 3.4 3.4 3.4 3.7 3 3.7 3.7 19 26 22 25 20 22 22 26 27 26 37 39 43 52 41 38 43 52 20 38 38 Nominal Fire Sound Sound Single Layer Width Resistance Insulation Insulation No Infill With Infill 12.5mm 15mm mm mins RwdB Rwdb 75 80 75 80 75 75 75 75 80 80 100 100 100 110 100 100 100 110 76 101 101 30 30 30 60 30 30 30 30 30 60 60 90 60 90 120 60 60 90 30 60 60 34 39 38 37 Double Layer 12.5m Test Reference 15mm S SR SR FR 40 43 44 44 45** 44 S FR SR IR SR FR 43 45 48 48 45 S S/FR SR SR FR S SR 49 54 55 SR S 42 BOXED STUDS BOXED STUDS BOXED STUDS S S 48 5001 5002 5003 5005 5006 5007 5008 5009 5022 5010 5011 5012 5013 5014 5015 5016 5017 5018 5019 5020 5021 70mm C Stud spaced at 600mm centres Part Grade Max Height Nominal Weight BS 5234 m Kg/m 2 MD MD HD HD HD MD MD MD HD HD HD HD SD SD SD SD SD SD SD SD SD MD 3.6 3.6 3.6 3.8 3.8 3.6 3.6 3.6 3.6 3.8 3.8 3.8 4.6 4.6 4.6 4.9 4.7 4.6 4.6 4.6 4.9 4.1 19 22 27 25 26 20 22 23 28 21 26 27 37 43 41 51 51 38 44 42 54 20 Nominal Fire Sound Sound Single Layer Width Resistance Insulation Insulation No Infill With Infill 12.5mm 15mm mm mins RwdB Rwdb 95 95 95 100 100 95 95 95 95 100 100 100 120 120 120 130 125 120 120 120 130 96 30 30 60 60 30 30 30 30 60 30 60 30 60 60 120 90 90 60 60 120 90 30 36 40 39 39 42 Double Layer 12.5m Test Reference 15mm S SR IR FR SR 41 45 47 47 42** 47 48 S FR SR IR S FR SR 46 52 48 52 S SR FR 53** 49 56 51 57 IR(0) S SR FR SR SR(I) SR S BOXED STUDS 7001 7002 7003 7004 7005 7006 7007 7008 7009 7023 7010 7011 7012 7013 7014 7015 7019 7016 7017 7018 7019 7020 Partitioning Systems Stud & Track Product Performance Guide 92mm C Stud spaced at 600mm centres Part Grade Max Height Nominal Weight BS 5234 m Kg/m 2 MD HD HD MD MD HD HD SD SD SD SD SD SD 3.9 4.4 4.4 3.9 4.2 4.4 4.4 5.2 5.2 5.9 5.2 5.2 5.9 20 26 27 21 22 26 27 38 42 51 39 43 51 Nominal Fire Sound Sound Single Layer Width Resistance Insulation Insulation No Infill With Infill 12.5mm 15mm mm mins RwdB Rwdb 115 120 122 115 115 120 122 140 140 152 140 140 152 30 60 30 30 30 60 30 60 120 90 60 120 90 36 39 42 Double Layer 12.5mm Test Reference 15mm S 9001 9004 9010 9003 9002 9005 9011 9006 9007 9012 9008 9009 9013 FR SR 41 45 47 47 S FR FR SR 46 49 52 S FR SR 49 54 54 S FR SR 146mm C Stud spaced at 600mm centres Nominal Weight Nominal Fire Sound Sound Single Layer Width Resistance Insulation Insulation No Infill With Infill 12.5mm 15mm mm mins RwdB Rwdb BS 5234 m Kgm2 MD 6.2 20 171 30 HD 6.5 26 176 60 SD SD SD SD SD SD SD SD SD SD SD SD 7.6 7.6 7.6 7.9 7.6 7.6 7.6 7.9 8.2 9.2 7.0 12.0 38 43 43 51 39 44 44 51 47 40 54 72 196 196 196 206 196 196 196 206 206 197 209 432 60 60 120 90 60 60 120 90 90 60 90 120 38 Double Layer 12.5mm Test Reference 15mm S 42 1001 FR 48 53 50 53 1002 S SR FR SR 52 57 56 57 53 48 S SR FR SR S S 60 71* BOXED STUDS S(19)/12.5SR 2 x 15FR/12.5S BOXED STUDS & TWIN FRAME 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 All Studs spaced at 600mm centres. All studs are single unless stated as BOXED or TWIN FRAME construction Cavity infills are 25mm glass mineral wool or 30mm rock mineral wool unless otherwise stated. *Denotes – Two 100mm glass mineral wool quilts. **Denotes – 50mm glass mineral wool quilt. Plasterboard codes are:S S(19) FR SR Standard plasterboard 19mm Standard plasterboard (Plank) Fire Resistant plasterboard Sound Resistant plasterboard IR Impact Resistant plasterboard With studs spaced at 400mm centres, maximum height can be increased by 0.3m for single board applications and 0.6m for double board installations. Fixtures Ceramic Tiling Heavy or medium duty fixtures must If ceramic tiles are being fixed to the be attached to the metal framework. finished wall, stud centres must be If necessary, additional framework reduced to prevent cracking of the tiles. must be added. For all systems the centres must be Partition Brace fixed horizontally reduced to 400mm. This applies between studs is particularly useful to C Studs, I Studs for Independent for hanging heating units, radiators, Wall Lining and Wall Liner. washbasins and cupboards etc. Please note: Tiles should only be fitted to double layer installations up to a maximum height of 3.6meters. Heights For heights between 4.0m and 8.0m Deep Track (50mm leg) should be used at the head and base. Stud & Track Max Height Partitioning Systems Part Grade 11 Partitioning Systems Stud & Track Fire & Acoustic Mastic Cloaking Angle Firestrip Sealant Mineral Fibre Deep Track Deep Track Stud Stud Partition Brace Partition Brace Deflection head When partitions are erected to span the full height between floors, structural slabs or beams, accommodation for movement may be needed. The deflection heads shown will allow for movement up to 25mm and protect the partition from damage. These details have been both tested for fire resistance to BS 476 part 20 & 22 section 5. Fix plasterboard, allowing for a 15mm deflection at the partition head; do not screw fix the plasterboard to the studs or track above the Partition Brace. * Above 25mm please refer to local branch. Electrical Services Acoustic Insulation To ensure they do not lie back to Insulation 25mm glass mineral wool insulation or 30mm rock mineral wool insulation to be installed 300mm above and 300mm below metal socket box for full width between studs Standard Plasterboard fixed to back of Flat Strip or Partition Brace End cut and bent to fit stud centres Partitioning Systems back, electrical sockets should be offset. Use Flat Strip or Partition Brace to support outlet boxes and seal around with acoustic sealant. Two layers, either side of 12.5mm standard plasterboard, will achieve 60 minutes of fire resistance. Clamping Strip Galvanised clamping strip is used to cover joints when building partitions. A plastic or aluminium cover section clips over the clamping strip to give a good 12 finished appearance. Clamping Strip Product Description 20mm Clamping Strip x 0.5mm Stock Lengths Metre 2.400 2.700 3.000 3.600 Weight per Length Kgs 0.28 0.32 0.36 0.42 Partitioning Systems Stud & Track High Performance Walls Lightweight, quick to construct, cost-effective, compact and able to Installation Benefits achieve high levels of fire resistance and acoustic insulation. I Studs at 300mm centres, staggered in track Non-load bearing High Performance Walls, constructed from plasterboard facings on metal studs, offer considerable advantages over traditional heavy Staggered I Stud system Staggered Stud Partitions Max Height m Nom Weight kg/m2 Nom Width mm 60 3.9 46 132 Fire Sound Test Resistance Insulation Reference mins RwdB 90 54 SS001 60mm I Stud at 300mm centres staggered in 72mm Track Two layers of 15mm Standard wallboard 50mm Glass mineral wool 60 3.9 47 132 90 56 SS002 60mm I Stud at 300mm centres staggered in 72mm Track Two layers of 12.5mm sound resistant wallboard. 25mm Glass mineral wool 60 3.9 56 120 60 59 SS003 60mm I Stud at 300mm centres staggered in 72mm Track Two layers of 15mm sound resistant wallboard. 25mm Glass mineral wool 60 3.9 57 130 90 59 SS004 Twin Frame Walls I Stud Frames (300mm overall) 2 layers 15mm sound resistant wallboard each side. No cross bracing 100mm Glass mineral wool I Stud Width mm Max Height m Nom Weight kg/m2 Nom Width mm 50 60 92 2.7 3.9 4.5 53 54 55 300 300 300 Fire Sound Test Resistance Insulation Reference mins RwdB 90 90 90 Note: Fire resistance and sound insulation performance figures apply laboratory test on elements imperforate partitions. Fire resistance information is based on the results of tests carried out to BS 476 : part 22 1987 or assessments based on these tests. Sound insulation is based on the results of tests carried out to BS EN ISO 140-3 : 1995. Single figure ratings (RW) have been calculated to BS EN ISO 717-1 : 1997. Some of our more recent fire tests have been conducted to European standard BS EN 1364-1 : 1999 which is actually more stringent than the existing British Standard BS 476. 69 69 69 Door frames simply formed Frames easily fit together Cut outs in studs for electrical and service requirements Sight line in studs for lining up with plasterboard TW001 TW002 TW003 Stud and track formed from pre-galvanised mild steel to BS EN 10143:1993 Stud & Track 60mm I Stud at 300mm centres staggered in 72mm Track Two layers of 15mm Standard wallboard 25mm Glass mineral wool I Stud Width mm Partitioning Systems masonry construction. Easy to cut to length using tin snips 13