www. hannainst.com/usa
Transcription
www. hannainst.com/usa
www. hannainst.com/usa Welcome to the HANNA instruments® Agricultural Products Catalog 5th Edition For well over two decades, HANNA instruments® has led the world with innovative solutions to agricultural testing needs. We know how important testing and controlling analytical properties is for effective nutrient management in both soil and irrigation water. Our world-wide research and development facilities are constantly working on new products to the benefit of our loyal customers. We understand that your measurement and control equipment must be well-built and perform with high reliability. All of our products are manufactured to the most stringent standards in state-of-the-art facilities to ensure the highest quality. HANNA® believes in supplying the agricultural community with a simple method for testing the HANNA instruments® parameters Agricultural Division Customer support that are It is our philosophy that the best way to support our customers is to be closer to them. HANNA instruments® has over 30 offices around the world to provide our customers with dedicated service that is "just around the corner". essential to Technical department It is our goal to provide each customer with easy access to one on one technical expertise for operational and application specific assistance. Extensive warranty All HANNA products are covered by a parts and labor warranty, ranging from six months to five years. Reliable products Over two decades of manufacturing instrumentation to ISO 9001 standards is reflected in every aspect of your HANNA instrument. Attractive pricing By developing and manufacturing every product in-house, HANNA pricing is a major source of envy for our competitors. We are reputed to offer the best value on the market. the proper growth of plants and vegetables. You will find that our products are extremely easy to use, economical and will assist you in growing superior crops — assuring Continuous innovation By listening closely to our customers, we are able to provide agricultural testing instruments that offer innovative features and exceptional reliability. that the quality of your product is Ready-to-use HANNA products are supplied with electrode(s), solutions and chemical reagents so they can perform right out of the box. Our field meters are supplied with a hard carrying case. Complete range In addition to an extensive range of pH and conductivity meters, we also manufacture electrodes, calibration and maintenance solutions, a complete range of application specific photometers, dissolved oxygen meters, thermometers and much more. HANNA online To view HANNA's complete line of products and applications, visit us on the web at www.hannainst.com. at its peak. Contents Testers . . . . . . . . . . . . . . . . . . . .4-11 Thermometers . . . . . . . . . . . . .34-37 pH/ORP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6 EC/TDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-8 Combination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Relative Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-11 1 or 4 channel Thermometers . . . . . . . . . . . . . . . . . . .34 Thermocouple Thermometers . . . . . . . . . . . . . . . .34-37 Infrared Thermistor Thermometer . . . . . . . . . . . . . . . .35 Thermocouple Probes . . . . . . . . . . . . . . . . . . . . . . . . .37 Monitoring & Control Portable Meters . . . . . . . . . . . .12-21 pH/ORP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-14 EC/TDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15-16 Combination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17-18 Dissolved Oxygen . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Relative Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 LUX (Light) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Nutrient Management Meters & Kits . . . . . . . . . . . . . . . . . .22-25 Suction Lysimeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 Grow Master N, P, K, Ammonia Photometer . . . . . . . .23 Ion Specific Photometers . . . . . . . . . . . . . . . . . . . .24-25 Chemical Test Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 Monitoring Systems . . . . . . . . .26-33 pH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 EC/TDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27-28 Combination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29-30 Hygrometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 Temperature Monitors and Dataloggers . . . . . . . .31, 33 . . . . . . . .38-54 Controller & NEMA Enclosure . . . . . . . . . . . . . . . . . . . . . .38 HANNA Customized Panels . . . . . . . . . . . . . . . . . . . . .39 Mini Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . .40-41 pH/ORP Panel Mount Controllers . . . . . . . . . . . . . . .42-43 EC/TDS Panel Mount Controllers . . . . . . . . . . . . . . . .44 pH Wall Mount Controllers . . . . . . . . . . . . . . . . . . . . . .45 ORP Wall Mount Controllers . . . . . . . . . . . . . . . . . . . .46 Combination Wall Mount Controllers . . . . . . . . . . . . . .47 Fertigation Wall Mount Controller . . . . . . . . . . . . . . . .48 Chemical Metering Pumps . . . . . . . . . . . . . . . . . . .48-49 RH/°C Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 Level Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 Acid Injection/pH Control Systems . . . . . . . . . . . . . .51-53 Complete Fertigation Systems . . . . . . . . . . . . . . . . . . .54 Warranty, Return & Exchange Policies . . . . . . . . . . .55 Contact Us HANNA instruments®, Inc. Highland Industrial Park 584 Park East Drive, Woonsocket, RI 02895 phone: (800) 426-6287 fax: (401) 765-7575 e-mail: web: agriculture@hannainst.com www.hannainst.com/usa Testers HI 98127 • HI 98128 Waterproof pH Testers The pHep®4 and pHep®5 include features such as a dual-level LCD, battery level indicator, replaceable pH electrode cartridge, stability indicator, automatic shut-off and automatic calibration all in a floating, waterproof casing. pHep®4 pHep®5 -2.0 to 16.0 pH -2.00 to 16.00 pH SPECIFICATIONS Range Resolution Accuracy (@20°C/68°F) 0.1 pH 0.01 pH ±0.1 pH ±0.05 pH Temp Range -5.0 to 60.0°C / 23.0 to 140.0°F Temp Accuracy ±0.5°C or ±1°F Temp Resolution 0.1°C or 0.1°F Auto Cal Buffers 4.01/7.01/10.01 or 4.01/6.86/9.18 pH Calibration Automatic 1 or 2 points Temp Compensation Automatic Battery Type (4) 1.5V with BEPS (Battery Error Prevention System) Battery Life Approx. 300 hours of continuous use; auto-off after 8 min. of non-use Environment 0 to 50°C (32 to 122°F); 100% RH Dimensions 163 x 40 x 26 mm (6.4 x 1.6 x 1”) Weight Replaceable pH electrode HANNA’s exclusive cartridge pH electrode. Electrode replacement with the stainless steel round connector means there are no pins to bend or break during replacement. 85 g (3.0 oz.) ORDERING INFORMATION ACCESSORIES HI 98127 (pHep®4) is supplied complete with protective cap, electrode removal tool, batteries and instructions. HI 73127 pH electrode HI 7004M pH 4.01 buffer solution, 250 mL HI 7007M pH 7.01 buffer solution, 250 mL HI 7010M pH 10.01 buffer solution, 250 mL HI 70004P pH 4.01, (25) 20 mL sachets HI 77400P pH 4 & 7, (10) 20 mL sachets, 5 ea. HI 70007P pH 7.01, (25) 20 mL sachets HI 70010P pH 10.01, (25) 20 mL sachets HI 70300L Storage solution, 500 mL HI 98128 (pHep®5) is supplied complete with protective cap, electrode removal tool, batteries and instructions. Renewable cloth junction When the cloth junction becomes dirty from routine testing, simply pull out 3 mm (1/8”) to rejuvenate the electrode. HI 98107 pHep® pH Tester with 2 point calibration • Easy-to-read LCD • 2-Point fast and accurate calibration • 1700 hours of battery life The Original pHep® pH tester set the standard for pH measurement. With 0.1 pH accuracy and 2 point calibration this ergonomic tester is an inexpensive and accurate solution for busy labs. Each instrument in the pHep® family comes with a protective cap that can be used as a measurement vessel. These testers are the standard in quick, on-the-spot pH testing. ORDERING INFORMATION: SPECIFICATIONS HI 98107 (pHep®) is supplied with protective cap, calibration screwdriver, batteries and instructions. Range Resolution ACCESSORIES: Accuracy (@20°C/68°F) HI 73106 Spare electrode for HI 98107 HI 70004P pH 4.01 buffer solution, (25) 20 mL sachets HI 70007P pH 7.01, buffer solution, (25) 20 mL sachets HI 70010P pH 10.01, buffer solution, (25) 20 mL sachets HI HI HI HI HI 7004M pH 4.01 buffer solution, 250 mL 7007M pH 7.01 buffer solution, 250 mL 7010M pH 10.01 buffer solution, 250 mL 70300M Electrode storage solution, 250 mL 7061M Cleaning solution, 250 mL pH Calibration HANNA instruments Agricultural Products Catalog ® 5th Edition 0.0 to 14.0 pH 0.1 pH ±0.1 pH Manual 2 points Battery Type (4) 1.5V Battery Life Approx. 1700 hours of continuous use Environment 0 to 50°C (32 to 122°F); max. 95% RH Dimensions 75 x 41 x 23 mm (7.9 x 1.8 x 1”) Weight 4 pHep® (HI 98107) 78 g (2.7 oz) With Great Products, Come Great Results.™ HI 98103 (Checker®1) SPECIFICATIONS Range Resolution Accuracy (@20°C/68°F) pH Calibration Battery Type Battery Life Environment Dimensions (meter only) Weight ® Checker 1 pH Tester • • • • Easy-to-read LCD High accuracy with 0.01 pH resolution 2-point fast and accurate calibration Usable with virtually any electrode that shares the same connector • 3000 hours of battery life • Full pH range: 0.00 to 14.00 pH ORDERING INFORMATION HI 98103 (Checker®1) is supplied complete with HI 1270 combination pH electrode, 2 x 1.5V batteries and instructions. At the cost of just a few rolls of litmus paper, you can have the industry's best pocket-sized pH tester. Unlike other pH testers, the pH electrode of the Checker® can be interchanged with any pH electrode of different size and shape that has the same connector. The Checker® is fast, accurate, lightweight and with 3000 hours of battery life you don't have to worry about frequent battery replacement. HI 981408 0.00 to 14.00 pH 0.01 pH ±0.2 pH Manual 2 points (2) 1.5V AA Approx. 3000 hours of continuous use 0 to 50°C (32 to 122°F); max. 95% RH 66 x 50 x 25 mm (2.6 x 2 x 1”) 70 g (2.5 oz) Testers HI 98103 ACCESSORIES HI HI HI HI HI HI HI 1270 pH electrode, screw connector 1207 pH electrode, screw connector 1208 pH electrode, BNC connector 7004M pH 4.01 buffer solution, 250 mL 7007M pH 7.01 buffer solution, 250 mL 7010M pH 10.01 buffer solution, 250 mL 70300L Storage solution, 500 mL Growers Field Checker® pH Stick Meter with User-replaceable Electrode • • • • • Shock-resistant casing Replaceable electrode Renewable cloth junction Water-resistant housing Runs on AA batteries The pH Gro’Chek® is an ideal meter for use anywhere liquid nutrient feeding is used. The rugged sensor was designed for mixing and incorporates a renewable cloth junction. The water and shock-resistant casing stands up to even harsh greenhouse environments. SPECIFICATIONS HI 981408 (pH Gro’Chek®) Range Resolution Accuracy (@20°C/68°F) pH calibration Battery Type Battery Life 0.0 to 14.0 pH 0.1 pH ±0.2 pH Manual 1 point (2) 1.5V AA Approx. 2000 hours of continuous use 0 to 50°C (32 to 122°F); Environment max. 95% RH Dimensions (meter only) 86 x 94 x 33 mm (3.4 x 3.7 x 1.3”) Weight 150 g (5.3 oz) Direct Sample pH Tester • • • • • Take measurements directly on the sample High accuracy with 0.01 pH resolution 2-point fast and accurate calibration Full 0.00 to 14.00 pH range Lightweight and pocket sized The Growers Field Checker® (HI 98103GC) allows the user to determine the pH of fruit and plant tissue in the field with just a few drops of sap or juice. If your sample does not contain sufficient liquid, add an equal portion of deionized water to extract the sample pH. Growers Field Checker® works with you to obtain superior crops. The Growers Field Checker® is supplied with a flat tip pH probe which allows for minimal liquid sample, soft carrying case, pH 4 and 7 calibration solutions, deionized water sachet, 100 mL sample beaker and screwdriver! ORDERING INFORMATION: SPECIFICATIONS HI 981408 is supplied complete with HI 1219 pH electrode, pH 7 buffer solution, batteries and instructions. Range Resolution Accuracy (@20°C/68°F) Calibration Battery Type Battery Life Environment Dimensions (meter only) Weight ACCESSORIES HI 77400P pH 4 & 7 buffer solution, (10) 20 mL sachets, 5 ea. HI 70007P pH 7.01, buffer solution, (25) 20 mL sachets HI 70000P Electrode rinse solution (25) 20 mL sachets HI 70300L Storage solution, 500 mL HI 7061M Electrode cleaning solution, 250 mL HI 1219 Double junction pH electrode HI 98103GC (Growers Field Checker®) 0.00 to 14.00 pH 0.01 pH ±0.2 pH Manual 2 points 2 x 1.5V AA Approx. 3000 hours of continuous use 0 to 50°C (32 to 122°F); max. 95% RH 66 x 50 x 25 mm (2.6 x 2 x 1”) 70 g (2.5 oz) www.hannainst.com/usa 5 Testers HI 98120 • HI 98121 pH/ORP and ORP Waterproof Testers • HANNA’s exclusive cartridge pH and ORP electrode Electrode replacement with the stainless steel round connector means there are no pins to bend or break during replacement. • Renewable cloth pH junction When the cloth junction becomes dirty from routine testing, simply pull out 3 mm (1/8”) to rejuvenate the electrode. (HI 98121) • • • • • Automatic temperature compensation Automatic calibration (HI 98121) Automatic shut-off Dual-level LCD “Direct Contact” temperature probe (HI 98121) HI 98120 is a waterproof ORP and temperature meter while HI 98121 measures pH, ORP and temperature. The housing of these testers have been completely sealed against humidity and are designed to float. The stainless steel encapsulated temperature sensor on these models facilitates faster and more accurate temperature measurement. SPECIFICATIONS Range Resolution Replaceable ORP electrode cartridge Replaceable pH electrode cartridge Accuracy (@20°C/68°F) HI 98120 HI 98121 ORP: ±1000 mV; Temperature: -5.0 to 60.0°C or 23.0 to 140.0°F pH: -2.00 to 16.00; ORP: ±1000 mV; Temperature: -5.0 to 60.0°C or 23.0 ORP: 1 mV; Temperature: 0.1°C or 0.1°F pH: 0.01; ORP: 1 mV; Temperature: 0.1°C or 0.1°F ORP: ±2 mV; Temperature: ±0.5°C or ±1°F pH: ±0.05; ORP: ±2 mV; Temperature: ±0.5°C or ±1°F Factory calibrated pH: 1 or 2 points with 2 sets of memorized buffers (pH 4.01/7.01/10.01 or pH 4.01/6.86/9.18); ORP: Factory calibrated - Automatic for pH Calibration ORDERING INFORMATION: HI 98120 is supplied complete with protective cap, electrode removal tool, batteries and instructions. HI 98121 is supplied complete with protective cap, electrode removal tool, batteries and instructions. Temp. Compensation Battery Type (4) 1.5V with BEPS (Battery Error Prevention System) Battery Life Approx. 250 hours of continuous use; auto shut-off after 8 minutes of non-use Environment -5 to 50°C (23 to 122°F); 100% RH Dimensions 163 x 40 x 26 mm (6.4 x 1.6 x 1”) Weight 85 g (3.0 oz.) ACCESSORIES HI HI HI HI HI 73127 pH electrode (HI 98121) 73120 ORP electrode (HI 98120) 7004M pH 4.01 buffer solution, 250 mL 7007M pH 7.01 buffer solution, 250 mL 7010M pH 10.01 buffer solution, 250 mL HI 98201 7021M ORP test solution (240 mV), 250 mL 7022M ORP test solution (470 mV), 250 mL 7020M 200/275 mV test solution, 250 mL 7091M Reducing solution, 250 mL 7092M Oxidizing solution, 250 mL SPECIFICATIONS ORP Oxidation Reduction Potential Portable Tester • Clog-resistant cloth junction • Platinum electrode • Covers full ORP range • Rugged housing In certain applications, ORP is used to determine the effects of soil compaction and the viability of the soil to maintain the proper level of oxygen. 6 HI HI HI HI HI Range Resolution Accuracy (@20°C/68°F) Battery Type/Life Environment Dimensions Weight ORP (HI 98201) ±999 mV 1 mV ±5 mV (4) 1.5V/Approx. 700 hours continuous use 0 to 50°C (32 to 122°F); 95% RH 175 x 41 x 23 mm (7.9 x 1.6 x 0.8”) 78 g (2.7 oz.) ORDERING INFORMATION: HI 98201 (ORP) is supplied complete with protective cap, batteries and instructions. ACCESSORIES: HI HI HI HI 73201 Spare electrode for ORP to be replaced by authorized technical personnel only 7020M 200/275 mV test solution, 250 mL 7091M Reducing solution, 250 mL 7092M Oxidizing solution, 250 mL HANNA instruments Agricultural Products Catalog ® HI 70004P pH 4.01, (25) 20 mL sachets HI 70007P pH 7.01, (25) 20 mL sachets HI 70010P pH 10.01, (25) 20 mL sachets HI 77400P pH 4 & 7, (10) 20 mL sachets, 5 ea. HI 70300L Storage solution, 500 mL 5th Edition With Great Products, Come Great Results.™ Testers HI 98311 • HI 98312 Waterproof EC/TDS/ Temperature Testers HANNA instruments® continues the tradition of innovation with the new DiST®5 and DiST®6. For this new series, we have included all the features you have asked for such as a replaceable graphite electrode, adjustable TDS ratio, temperature in °C or °F, automatic temperature compensation with adjustable b, battery level indicator, stability indicator, automatic shut-off, and automatic calibration all in a floating, waterproof casing. These 3-in-1 testers are unmatched in EC/TDS/ Temperature measurement! DiST®5 (HI 98311) DiST®6 (HI 98312) EC: 0 to 3999 μS/cm; TDS: 0 to 2000 ppm; Temperature: 0.0 to 60.0°C or 32.0 to 140.0°F EC: 0.00 to 20.00 mS/cm; TDS: 0.00 to 10.00 ppt; Temperature: 0.0 to 60.0°C or 32.0 to 140.0°F EC: 1 μS/cm; TDS: 1 ppm; Temperature: 0.1°C or 0.1°F EC: 0.01 mS/cm; TDS: 0.01 ppt; Temperature: 0.1°C or 0.1°F EC: ±2% F.S.; TDS: ±2% F.S.; Temperature: ±0.5°C or ±1°F EC: ±2% F.S.; TDS: ±2% F.S.; Temperature: ±0.5°C or ±1°F SPECIFICATIONS Range Resolution Accuracy(@20°C/68°F) EC/TDS Calibration EC/TDS Conv. Factor Temp. Compensation Battery Type Battery Life Environment Dimensions Weight Automatic 1 point Adjustable from 0.45 to 1.00 Automatic, BETA (β) is adjustable from 0.0 to 2.4%/°C (4) 1.5V with BEPS (Battery Error Prevention System) Approx. 100 hours of continuous use; auto shut-off after 8 minutes of non-use 0 to 50°C (32 to 122°F); 100% RH 163 x 40 x 26 mm (6.4 x 1.6 x 1”) 85 g (3.0 oz.) ORDERING INFORMATION: ACCESSORIES: HI 98311 (DiST®5) is supplied complete with protective cap, batteries, probe removal tool and instructions. HI HI HI HI HI HI HI HI 98312 (DiST®6) is supplied complete with protective cap, batteries, probe removal tool and instructions. 73311 Spare probe 70030P 12.88 mS/cm calibration solution, (25) 20 mL sachets 70031P 1413 μS/cm calibration solution, (25) 20 mL sachets 70032P 1382 ppm calibration solution, (25) 20 mL sachets 70038P 6.44 ppt calibration solution, (25) 20 mL sachets 70442P 1500 ppm calibration solution, (25) 20 mL sachets 73128 Probe removal tool Original DiST® Series • Automatic temperature compensation • Graphite sensors • Simple calibration EC and TDS Testers The Original DiST® family of testers are reliable pocket-sized instruments that provide quick and accurate readings at an affordable price. The graphite sensors of these meters offer better repeatability since they do not oxidize and Automatic Temperature Compensation (ATC) assures that all readings are corrected to compensate for the effects of temperature. DiST® 1 and DiST® 2 measure TDS, while DiST®3 and DiST®4 measure conductivity. SPECIFICATIONS DiST®1 (HI 98300/HI 98301) DiST 2® (HI 98302) DiST®3 (HI 98303) DiST®4 (HI 98304) Range Resolution 0 to 1999 ppm (mg/L) 1 ppm (mg/L) 0.00 to 10.00 ppt (g/L) 0.01 ppt (g/L) 0 to 1999 μS/cm 1 μS/cm 0.00 to 19.99 mS/cm 0.01 mS/cm ±2% F.S. ±2% F.S. ±2% F.S. ±2% F.S. Accuracy(@20°C/68°F) TDS Factor Calibration Solution Calibration Temp. Compensation Battery Type/Life Environment Dimensions/ Weight 0.65/0.5 HI 70032P/HI 70442P 0.5 HI 70038P HI 70031P Manual 1 point through trimmer Automatic from 0 to 50°C (32 to 122°F) (4)1.5V/Approx. 150 hours of continuous use 0 to 50°C (32 to 122°F); max. 95% RH 175 x 41 x 23 mm (7.9 x 1.8 x 1”)/78 g (2.7 oz) ORDERING INFORMATION ACCESSORIES HI 98300, HI 98301, HI 98302, HI 98303 and HI 98304 are supplied with protective cap, batteries and instructions. HI 7030M 12.88 mS/cm@25°C cal solution, 250 mL HI 70030P 12.88 mS/cm@25°C cal sol., (25) 20 mL sachets HI 7031M 1413 μS/cm @ 25°C cal solution, 250 mL HI 70031P 1413 μS/cm @ 25°C cal. kit (25) 20 mL sachets HI 7032M 1382 ppm@25°C cal solution, 250 mL HI HI HI HI HI HI 70039P/HI 70030P 70032P 1382 ppm @ 25°C cal. kit, (25) 20 mL sachets 70442P 1500 ppm @ 25°C cal. kit, (25) 20 mL sachets 70038P 6.44 ppt @ 25°C cal. kit, (25) 20 mL sachets 7039M 5000 μS/cm @25°C cal. solution, 250 mL 70039P 5000 μS/cm @ 25°C cal. kit, (25) 20 mL sachets www.hannainst.com/usa 7 Testers HI 981410 SPECIFICATIONS EC, Floating Stick Meter with User-replaceable Electrode Resolution • • • • • HI 981410 (EC Gro’Chek) Range Water Resistant Automatic Calibration Automatic Temperature Compensation Ideal for Mixing Fertilizer ppm Model Available for TDS (HI 981409) The EC Gro’Chek® is ideal for use anywhere liquid nutrient feeding is used. The rugged sensor was designed for mixing, while the water and shock resistant casing stands up to even harsh greenhouse environments. The EC Gro’Chek® utilizes AA batteries and has an auto shut-off after 5 minutes for long battery life. 0.00 to 10.00 mS/cm 0.01 mS/cm Accuracy (@20°C/68°F) ±2% F.S. Battery Type/Life (2) 1.5V/Approx. 300 hours continuous use Environment 0 to 50°C (32 to 122°F); 100% RH Dimensions 89 x 94 x 33 mm (3.4 x 3.7 x 1.3”) Weight 150 g (5.8 oz.) ORDERING INFORMATION: HI 981410 (EC Gro’Chek) is supplied with HI 1220 interchangeable TDS probe, 1500 ppm calibration solution sachet, batteries and instructions. ACCESSORIES HI HI HI HI 70039P 5000 μS/cm @ 25°C cal. kit, (25) 20 mL sachets 7061M Electrode cleaning solution, 250 mL 70300M Electrode storage solution, 250 mL 1220 Conductivity probe, L: 240 mm, DIN connector HI 98331 Soil Test HI 983311 Direct Soil Conductivity and Temperature Tester EC/TDS/Temperature Tester • Dual level LCD • Probe can be used as a stirrer • HOLD button to freeze display • Auto shut-off • Automatic temperature compensation • Penetration probe • Lightweight and portable The HI 98331 is a special pocket tester designed to directly measure soil conductivity and temperature. With an incorporated sensor in the penetration probe, readings are automatically temperature compensated. Conductivity range can be calibrated at one point and is designed to be calibrated in liquid. SPECIFICATIONS Range Resolution To perform simple and fast EC, TDS and Temperature measurements in places with a high percentage of humidity, HANNA instruments® offers the Aqua Dip. With only two operation buttons, the Aqua Dip allows an immediate and precise response. Aqua Dip is factory calibrated and offers total protection against humidity which makes Aqua Dip ideal for analysis in the field. HI 98331 Two models are available: Conductivity: 0.00 to 4.00 mS/cm (dS/m); Temperature: 0.0 to 50.0°C Conductivity: 0.01 mS/cm; Temperature: 0.1°C Accuracy (@20°C/68°F) Temp. Compensation Calibration Probe Battery Type Environment Dimensions Weight Conductivity: ±0.05 mS/cm (0.00 to 2.00 mS/cm), ±0.30 mS/cm (2.00 to 4.00 mS/cm); Temperature: ±1°C Automatic, Temperature coefficient (β) fixed @ 2%/°C Manual 1 point HI 73331 122 mm (4.5”) penetration 4 x 1.5V 0 to 50°C 163 x 40 x 26 mm (6.4 x 1.6 x 1.0”) 100 g (3.5 oz) ACCESSORIES 73331 Direct soil penetration conductivity probe 7031M 1413 μS/cm (1.4 mS/cm) @25°C calibration solution, 250 mL 7031L 1413 μS/cm (1.4 mS/cm) @25°C calibration solution, 500mL 731326 Calibration screwdrivers (20) HANNA instruments Agricultural Products Catalog ® HI 983311/5 with 0.5 TDS factor HI 983311/7 with 0.7 TDS factor HI 983311 (Aqua Dip) Resolution Accuracy (@20°C/68°F) EC: 0 to 3999 μS/cm; TDS: 0 to 2000 ppm; Temperature: 0.0 to 60.0°C EC: 1 μS/cm; TDS: 1 ppm; Temperature: 0.1°C EC/TDS: ±2% F.S.; Temperature: ±0.5°C TDS Factor Temp. Compensation Battery Type/Life Environment Dimensions Weight 0.5 (HI 983311/5) or 0.7 (HI 983311/7) Automatic with β=2.1%/°C (2) 1.5V AAA/Approx. 180 hours continuous use 0 to 50°C (32 to 122°F); 100% RH 94 x 38 x 440 mm (3.7 x 1.5 x 17.3”) 200 g (7.8 oz.) Range HI 98331 (Soil Test) is supplied with HI 73331 penetration conductivity probe, (4) 1.5V batteries, calibration screwdriver and instructions. 8 • • SPECIFICATIONS ORDERING INFORMATION: HI HI HI HI Aqua Dip ORDERING INFORMATION HI 983311 (Aqua Dip) is supplied with batteries and instructions. 5th Edition With Great Products, Come Great Results.™ Combo Testers HI 98129 • HI 98130 pH/Conductivity/TDS Waterproof Tester Replaceable pH electrode cartridge The Combo features an easy-to-replace pH electrode has an extendable cloth junction. The sturdy, snap-in connector means there are no pins to bend or break. High accuracy The graphite conductivity electrode provides greater accuracy because it cannot be contaminated by salt deposits in the solution. The exposed temperature sensor provides fast response times, and guarantees accurate temperature compensated readings. The HI 98129 and HI 98130 Combo waterproof testers offer high accuracy pH, EC/TDS and temperature measurements with a large easy-to-read, dual-level LCD and automatic shut-off. pH and EC/TDS readings are automatically compensated for the effects of temperature (ATC). The EC/TDS conversion factor is user selectable as well as the temperature compensation coefficient (β). Fast, efficient, accurate and portable, the Combo incorporates all the features asked for and more! SPECIFICATIONS Range Resolution Combo (HI 98129) Combo (HI 98130) pH: 0.00 to 14.00; EC: 0 to 3999 μS/cm; TDS: 0 to 2000 ppm; Temperature: 0.0 to 60.0°C or 32.0 to 140.0°F pH: 0.00 to 14.00; EC: 0.00 to 20.00 mS/cm; TDS: 0.00 to 10.00 ppt; Temperature: 0.0 to 60.0°C or 32.0 to 140.0°F pH: 0.01; EC: 1 μS/cm; TDS: 1 ppm; Temperature: 0.1°C or 0.1°F pH: 0.01; EC: 0.01 mS/cm; TDS: 0.01 ppt; Temperature: 0.1°C or 0.1°F Accuracy (@20°C/68°F) pH Calibration EC/TDS Calibration EC/TDS Conv. Factor Temp Comp. Battery Type Battery Life Environment Dimensions/Weight pH: ±0.05; EC/TDS: ±2% F.S.; Temperature: ±0.5°C or ±1°F 1 or 2 points with 2 sets of memorized buffers Automatic 1 point Adjustable from 0.45 to 1.00 pH: automatic; EC/TDS: automatic, BETA (β) is adjustable from 0.0 to 2.4%/°C (4) 1.5V with BEPS (Battery Error Prevention System) Approx. 100 hrs of continuous use; auto shut-off after 8 minutes of non-use 0 to 50°C (32 to 122°F); 100% RH 163 x 40 x 26 mm (6.4 x 1.6 x 1”)/85 g (3.0 oz.) ORDERING INFORMATION ACCESSORIES HI 98129 (Combo) is supplied with protective cap, electrode removal tool, batteries and instructions. HI 73127 Replaceable pH electrode HI 7004M pH 4.01 buffer solution, 230 mL HI 7007M pH 7.01 buffer solution, 230 mL HI 7010M pH 10.01 buffer solution, 230 mL HI 70004P Cal. kit (pH 4.01, 20 mL, 25 pcs.) HI 77400P pH 4 & 7 buffer solution, (10) 20 mL sachets, 5 ea. HI 70007P pH 7.01 buffer solution, (25) 20 mL sachets HI 70010P pH 10.01 buffer solution, (25) 20 mL sachets HI 98130 (Combo) is supplied with protective cap, electrode removal tool, batteries and instructions. HI HI HI HI HI HI HI 70031P 1413 μS/cm @ 25°C cal. kit, (25) 20 mL sachets 70032P 1382 ppm @ 25°C cal. kit, (25) 20 mL sachets 70038P 6.44 ppt @ 25°C cal. kit, (25) 20 mL sachets 70030P 12880 mS/cm @ 25°C cal. kit, (25) 20 mL 70442P 1500 ppm @ 25°C cal. kit, (25) 20 mL sachets 70300M Storage solution, 250 mL 7061M Electrode cleaning solution, 250 mL HI 98601 HYGROCHECK Relative Humidity Tester Now growers can have accurate readings in a pocket sized tester! The Hygrocheck’s large LCD can be seen from any angle. Housed in rugged ABS plastic, the Hygrocheck uses HANNA instruments® Thin Film Polymer Capacitor Sensor. SPECIFICATIONS HI 98601 (Hygrocheck) Range 0.1% RH Accuracy (@20°C/68°F) ±3% F.S. Battery Type/Life • • • • Large LCD Pocket sized Common sense construction No conversions necessary 10.0 to 90.0% RH Resolution (3) 1.5V/Approx. 100 hours continuous use Environment 0 to 50°C (32 to 122°F); 95% RH Dimensions 175 x 41 x 23 mm (7.9 x 1.6 x 0.8”) Weight 78 g (2.7 oz.) ORDERING INFORMATION HI 98601 (Hygrocheck) is supplied with protective cap, batteries, soft carrying case and instructions. www.hannainst.com/usa 9 Testers HI 151 Plant Stress Ideal soil temperature is a constant 70°F for most plants.You should take readings during peak sunlight hours. Stainless Steel, Folding Penetration Probe Thermometer with CAL-CHECK™ Factory Calibration Certificates • Ergonomic and easy to carry • Large LCD • Cal-Check™ feature • Auto shut-off • °C model available Your thermometer will be calibrated against a NIST standard and a certificate will be issued. HANNA’s Exclusive Cal-Check Feature The Checktemp® 4 gives you practical solutions to temperature measurement for food service. As you unfold the stainless steel probe, the Checktemp® 4 automatically turns ON and immediately performs a calibration test. This unique HANNA feature, Cal-Check™, provides you the security of knowing you have accurate measurements. Cal-Check™ lets you know if your battery level is too low or if your thermometer requires re-calibration. SPECIFICATIONS Range Resolution Accuracy Probe Battery Type/Life Environment Dimensions Weight HI 151 (Checktemp®4) -58.0 to 428°F 0.1°F (-58.0 to 199.9°F, 1°F (200 to 428°F) ±0.8°F/±1% F.S. (outside) Stainless Steel, penetration; 117 x 3.5 mm (6.75 x .187”) (1) 1.5V/Approx. 25,000 hours continuous use 0 to 50°C (32 to 122°F); 95% RH 165 x 50 x 20 mm (6.5 x 2.0 x 0.8’’) 100 g (3.6 oz.) ORDERING INFORMATION HI 151-01 (°F) is supplied with 1.5V AAA battery, wrist strap & instruction manual. HI 151-001 (°F) is supplied with factory calibration certificate, 1.5V AAA battery, wrist strap & instruction manual. How do you know when the reading on any thermometer is correct? You could make an ice point or slurry. Even then there could be several degrees difference in the real and the theoretical or perceived temperatures. With our exclusive CALCHECK™ feature, you do not need to waste time preparing for and making these tests, CAL-CHECK™ can do it for you. You can check the accuracy and deviation of your thermometer at any time during its life. This way, you are always sure about the accuracy of your readings and if necessary, can manually compensate for any deviation in calibration. HI 98510 Checktemp®1: Thermometer with Remote Probe •3-foot probe cable •Calibration check™ feature (CAL-CHECK™) •Long battery life •°C model available This highly accurate thermometer is equipped with HANNA’s unique calibration device which allows the user to ensure that the instrument is calibrated accurately. The 3-foot cable is ideal for checking temperature in hard to reach places. HI 98510 (Checktemp®1) SPECIFICATIONS Range Resolution Accuracy Probe Battery Type/Life Environment Dimensions Weight -58.0 to 302.0°F 0.1°F ±0.5°F (-4 to 194°F) / ±1°F (outside) stainless steel, 160 x dia 3 mm (6.3 x dia 0.1’’), with 1 m (3.3’) cable 1.5 V AAA / approx. 3 years of use 0 to 50°C (32 to 122°F); RH max 95% 106 x 58 x 19 mm (4.2 x 2.3 x 0.7’’) 80 g (2.8 oz.) - meter only ORDERING INFORMATION ACCESSORIES HI 98510 (Checktemp® 1 °F) is supplied complete with battery and instructions. HI 740024 Base for Checktemp® 1 HI 98510-01 (Checktemp® Dip °F) is supplied complete with weighted probe with 3 m (10’) cable, battery and instructions. 10 HANNA instruments Agricultural Products Catalog ® 5th Edition With Great Products, Come Great Results.™ HI 145 Thermometer with Stainless Steel Probe Soil Thermometer • • • • • Stainless steel probe • Calibration Check feature (CAL-CHECK™) • Long battery life • °C model available This highly accurate thermometer is equipped with HANNA’s unique calibration device which allows the user to ensure that the instrument is calibrated accurately. The Checktemp® offers better accuracy than glass thermometers, features a large LCD and stainless steel 105mm (4.13”) probe. ORDERING INFORMATION HI 98502 (Checktemp® °F) is supplied with penetration probe, protective cap, battery and instructions. T-shaped with easy-to-read display Available with 5” or 12” probe °C model available Cal-Check™ feature The HI 145 series was designed to measure soil temperature quickly and accurately up to depths of 12 inches. Equipped with a calibration check feature, the user can be assured that each reading is accurate. The T-shaped design and large LCD make the HI 145 easy to spot measure or leave in place. ORDERING INFORMATION HI 145-01 with 125 mm (4.9'') probe is supplied with battery and instructions. HI 145-30 with 300 mm (11.8'') probe is supplied with battery and instructions. A Factory Calibration Certificate is available. Ask your sales associate. SPECIFICATIONS HI 145 Range Range Resolution Accuracy Probe Battery Type/Life Environment Dimensions Weight -58.0 to 428°F HI 98502 (Checktemp® °F) Resolution 0.1°F (-58.0 to 199.9°F, 1°F (200 to 428°F) -58.0 to 302.0°F 0.1°F (58.0 to 199.9°F); 1°F (200 to 302°F) ±0.5°F (-4 to 194°F) / ±1°F (outside) Fixed, stainless steel, 105 mm x dia 3 mm (4.1'' x dia 0.1''), (penetration) (1) 1.5V/ approx. 3000 hours continuous use 0 to 50°C (32 to 122°F); RH max 95% 66 x 50 x 25 mm (2.6 x 2.0 x 1.0’’) 50 g (1.8 oz.) - meter only Accuracy ±0.5°F (-4 to 194°F), ±0.4% F.S. (outside) SPECIFICATIONS Testers HI 98502 Checktemp® Probe Battery Type/Life HI 145-01), 5'' Stainless Steel (H HI 145-30) 12'' Stainless Steel (H (1) 1.5V/Approx. 10,000 hours continuous use Environment 0 to 50°C (32 to 122°F); 95% RH Dimensions HI 145-01: 92 x 165 x 38 mm (3.6 x 6.5 x 1’’) HI 145-30: 92 x 340 x 38 mm (3.6 x 13.4 x 1.5’’) Weight 65 g (2.4 oz.) HI 147 Checkfridge™ Temperature Monitor with Magnetic Backing & Remote Thermistor Sensor on a 1-Meter Cable • • • • Magnetic backing Cal-Check™ feature Large easy-to-read display °C model available A Factory Calibration Certificate is available. Ask your sales associate. SPECIFICATIONS Range Resolution Accuracy Probe Battery Type/Life Environment Dimensions Weight HI 147 is the ideal thermometer when you need accurate, reliable internal temperature monitoring from the outside. The HI 147 incorporates HANNA’s unique Cal-Check™ feature which allows the user to calibrate the thermometer internally. A low battery warning “ERR” message completes the HI 147’s rich features. HI 147 (Checkfridge™) -58.0 to 302.0°F 0.1°F (-20.0 to 199.9°F); 1°F (200 to 302°F) ±0.5°F (-4 to 194°F)/±1°F (outside) Fixed, stainless steel, 40 x 5 mm (1.5 x .187''), 1 m silicon cable 1.5V AAA/ approx. 3 years 0 to 50°C (32 to 122°F); RH max 95% 93 x 39 x 31 mm (3.7 x 1.5 x 1.2’’) 60 g (2.1 oz.) - meter only ORDERING INFORMATION HI 147-01 (Checkfridge™°F) is supplied with battery and instructions. www.hannainst.com/usa 11 Portable Meters HI 99121 Direct Soil pH and Temperature Kit with Special Electrode • • • • Specialized electrode High accuracy Fast response Automatic temperature compensation The HI 99121 kit has been designed to address the question of correct and rapid measurement of pH directly in soil. Every item in this kit has been made to facilitate measurements in the field without compromising accuracy. With HI 99121 you can test the pH of soil directly or after preparation of a diluted sample. In order to measure the pH directly, the kit includes a plastic auger to perforate the ground. The HI 1292D pH electrode has been designed for direct soil measurement. It has a conic, rugged tip and can be directly inserted in moist or soft soil. The electrode incorporates a temperature sensor right near the tip to enable it to measure and compensate for the temperature quickly. For higher degrees of accuracy, or for stony ground where the electrode may be damaged, use the specially made HI 7051M soil preparation solution. This solution is included in the package to help you measure pH more precisely by diluting a sample of the soil in it. The dual-level LCD shows the pH value from -2 to 16 with 0.01 resolution. It also displays the temperature on the secondary level at the same time. With a menu-driven custom microprocessor, the user is helped with clear prompts during operation and calibration. SPECIFICATIONS Compost Temperature HI 99121 Range pH: -2.00 to 16.00; Temperature: -5.0 to 60.0°C/23.0 to 221.0°F Resolution pH: 0.1; Temperature: 0.1°C/0.1°F Accuracy (@20°C/68°F) pH: ±0.02; Temperature: ±0.5°C up to 60°C, ±1°C (outside)/±1.0°F up to 140°F, ±2°F (outside) pH Calibration Automatic 1 or 2 points with 2 sets of memorized buffers (pH 4.01, 7.01, 10.01 or 4.01, 6.86, 9.18) Temp. Compensation Battery Type/Life Automatic, -5 to 105°C (23 to 221°F) Maintain a minimum pile temperature of 131°F for 3 days to destroy weed seeds or plant pathogens. Seed Beds Proper soil temperature for seed germination allows for higher sprouting in seed beds. (3) 1.5V AA/Approx. 1500 hours of continuous use; auto-off after 8 min. of non-use Environment 0 to 50°C (32 to 122°F); 100% RH Dimensions 150 x 80 x 36 mm (5.9 x 3.1 x 1.4'') Weight Pounds of Aluminum Sulfate to Lower the Soil pH per 10 sq. ft. 210 g (7.4 oz.) Present pH ORDERING INFORMATION HI 99121 is supplied complete with HI 1292D pH electrode, ground auger, HI 7051M soil preparation solution, pH 4 and pH 7 buffer sachets, HI 700663 and HI 700664 electrode cleaning solutions, batteries, rugged carrying case and instructions. ACCESSORIES HI 1292D pH electrode for soil measurement, with internal temperature sensor and DIN connector HI 7004L pH 4.01 buffer solution, 500 mL HI 7007L pH 7.01 buffer solution, 500 mL HI 70004P pH 4.01 sol., (25) 20 mL sachets HI 70007P pH 7.01, sol., (25) 20 mL sachets HI 7071 Electrolyte solution, (4) 30 mL HI 7051M Soil preparation solution, 250 mL HI 721319 Ground auger HI 700663P Cleaning solution for inorganic soil deposits, (25) 20 mL sachets HI 700664P Cleaning solution for organic soil deposits, (25) 20 mL sachets HI 710007 Shockproof rubber boot, blue HI 710008 Shockproof rubber boot, orange Desired pH 8.0 1.8 2.4 3.3 4.2 4.8 7.5 1.2 2.1 2.7 3.6 4.2 7.0 .06 1.2 2.1 3.0 3.6 .06 1.5 2.4 2.7 6.0 5.5 5.0 4.5 6.5 lbs. to add 6.5 Reduce Rate 1/3 for Sandy Soil Pounds of Sulfur to Lower the Soil pH per 10 sq. ft. Present pH Desired pH 8.0 1.8 2.4 3.3 4.2 4.8 7.5 1.2 2.1 2.7 3.6 4.2 7.0 .06 1.2 2.1 3.0 3.6 .06 1.5 2.4 2.7 6.0 5.5 5.0 4.5 6.5 lbs. to add 6.5 Increase Rate 1/2 for Clay Soil 12 HANNA instruments Agricultural Products Catalog ® 5th Edition With Great Products, Come Great Results.™ Portable Meters HI 9026 pH/ORP Meter with Calibration Check™ • • • • • • • • • • Electrode monitoring 7 memorized buffers for calibration Custom calibration with two custom buffers Display hold and memory storage Real time clock for accurate calibration monitoring User-selectable calibration reminder Extended pH and temperature ranges Measures in °C or °F Backlit, dual-level LCD Waterproof Calibration Check™ System Clean Electrode Each time pH calibration is performed, the meter internally compares the new calibration with the one previously stored. When this comparison indicates a significant difference, the clean message blinks on the LCD to advise the user that the pH electrode may need to be cleaned and another calibration will need to be performed. Expired Calibration The instrument is provided with a real time clock (RTC) in order to monitor the time elapsed since the last pH calibration. The RTC is reset every time the meter detects a calibration time-out. The CAL tag will start blinking to warn the user that the meter should be calibrated. Electrode Condition HI 9026 is an advanced pH/ORP meter specifically designed to provide affordable and very precise results under harsh agricultural conditions. The meter also features a backlit display for clear readings in the darkest environments. The HI 9026W display features a bar graph which displays the status of the electrode after calibration. The bargraph remains active for 12 hours after calibration, then only the frame is shown on the display. 81 to 100% Life In addition, the user can program 2 custom buffer values, in order to best fit the characteristics of the sample. HI 9026 is housed in a waterproof casing and can also be used with ORP electrodes. 61 to 80% Life 41 to 60% Life It comes complete with HI 1230B pH electrode and HI 7662 temperature probe to provide automatically compensated measurements. SPECIFICATIONS ORDERING INFORMATION Resolution HI 9026 is supplied complete with HI 1230B pH electrode, HI 7662 temperature probe, pH 4 and pH 7 buffer sachets, 100 mL plastic beaker, batteries, rugged carrying case and instructions. Range Accuracy (@20°C/68°F) Calibration Check™ 21 to 40% Life 1 to 20% Life 0% Life HI 9026 pH: -2.00 to 16.00; mV: ±699.9 to ±1999; Temperature: -20.0 to 120.0°C/-4.0 to 2482.0°F pH: 0.01; mV: 0.1, 1; Temperature: 0.1°C/0.1°F pH: ±0.01; mV ±0.2, ±1; Temperature: ±0.4°C/±0.8°F Check of the electrode status during calibration Automatic, 1 or 2 point with 7 memorized buffer values (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45); + 2 custom buffers ACCESSORIES pH Calibration HI 1230B pH electrode, gel filled, PEI body, BNC connector, 1 m cable HI 3230B ORP electrode, gel filled, PEI body, BNC connector, 1 m cable HI 7662 Temperature probe HI 76405 Electrode holder HI 7001L pH 1.68 buffer solution, 500 mL HI 7004L pH 4.01 buffer solution, 500 mL HI 7006L pH 6.86 buffer solution, 500 mL HI 7007L pH 7.01 buffer solution, 500 mL HI 7009L pH 9.18 buffer solution, 500 mL HI 7010L pH 10.01 buffer solution, 500 mL HI 70300L Electrode storage solution, 500 mL Temp Comp Automatic or manual, -20 to 120°C (-4°F to 248°F) pH Electrode HI 1230B, double junction, PEI body, gel filled, BNC connector and 1 m cable (included) Temperature Probe HI 7669 with 1 m (3.3’) cable (included) Input Impedance 1012 Ohm Battery Type/Life (4) 1.5V AA / approx. 500 hours of continuous use (without backlight); auto-off after 20 minutes of non-use (can be disabled) Environment 0 to 50°C (32 to 122°F); 100% RH Dimensions 196 x 80 x 60 mm (7.7 x 3.1 x 2.4’’) Weight 500 g (1.1 lb.) www.hannainst.com/usa 13 Portable Meters HI 9025 pH/ORP/Temperature Meter • • • • Specialized Electrode High Accuracy Fast Response Automatic Temperature Compensation The HI 9025C measures pH, temperature and ion concentration and ORP in the mV range all in a rugged, waterproof casing. The Auto-Instruction feature guides the user step-by-step through the calibration process with graphic symbols. Unlike conventional microprocessor pH meters that offer only the standard pH buffer solutions of 4.01, 7.01 and 10.01 for calibration, these meters also allow calibration at the important NBS (NIST) buffers of 6.86 and 9.18. Because the electrode requires a certain amount of time to stabilize between buffers, the meter will display the READY symbol only when the electrode has stabilized. The powerful HI 9025C will allow 1 or 2-point calibration using any of the 5 memorized buffers. SPECIFICATIONS HI 9025 pH: 0.00 to 14.00; mV: ±399.9 to ±1999; Temperature: 0.0 to 100.0°C/32.0 to 212.0°F Range Resolution ORDERING INFORMATION HI 9025 is supplied complete with HI 1230B pH electrode, HI 7669/2W temperature probe, pH 4 and pH 7 buffer sachets, 100 mL plastic beaker, batteries, rugged carrying case and instructions. pH: 0.01; mV: 0.1, 1; Temperature: 0.1°C/0.1°F Accuracy (@20°C/68°F) pH Calibration pH: ±0.01; mV: ±0.2, ±1; Temperature: ±0.4°C/±0.8°F Automatic, 1 or 2 point with 5 memorized buffer values (pH 4.01, 6.86, 7.01, 9.18, 10.01); offset calibration: ±1 pH; slope calibration: 70 to 108% Temp. Compensation pH Electrode Automatic or manual, -5 to 105°C (23°F to 221°F) HI 1230B, double junction, PEI body, gel filled, BNC connector and 1 m cable (included) Temperature Probe HI 7669/2W with 1 m (3.3’) cable (included) Environment 1012 Ohm (4) 1.5V AA / approx. 500 hours of continuous use;auto-off after 20 minutes of non-use (can be disabled) 0 to 50°C (32 to 122°F); 100% RH Dimensions 196 x 80 x 60 mm (7.7 x 3.1 x 2.4’’) Input Impedance Battery Type/Life Weight 500 g (1.1 lb.) SPECIFICATIONS HI 8424NEW Resolution Accuracy pH Calibration Temp. Compensation pH Electrode Temperature Probe Input Impedance Automatic, 1 or 2 point with 3 memorized buffer values (pH 4.01, 7.01, 10.01); offset calibration: ±1 pH; slope calibration: 75 to 110% Automatic -20 to 120°C (-4°F to 248°F) or manual HI 1230B, double junction, PEI body, gel filled, BNC connector and 1 m cable (included) HI 7669 with 1 m (3.3’) cable (included) 1012 Ohm Battery Life (1) 9V/approx. 150 hours of continuous use; auto-off after 20 minutes of non-use (can be disabled) Environment Dimensions Weight 0 to 50°C (32 to 122°F); 100% RH 164 x 76 x 45 mm (6.5 x 3.0 x 1.8’’) 180 g (6.3 oz.) ORDERING INFORMATION HI 8424NEW is supplied with HI 1230B pH electrode, HI 7662 temperature probe, calibration and cleaning solutions, battery, protective case and instructions. ACCESSORIES HI 1230B pH electrode, gel filled, PEI body, BNC connector HI 1332B ORP electrode, gel filled, PEI body, BNC connector HI 7662 Temperature probe HI 76405 Electrode holder HI 7004L pH 4.01 buffer solution, 500 mL 14 HI 7007L pH 7.01 buffer solution, 500 mL HI 7010L pH 10.01 buffer solution, 500 mL HI 70300L Electrode storage sol, 500 mL HI 710015 Shockproof rubber boot, blue HI 710016 Shockproof rubber boot, orange HI 710022 Spare protective case HANNA instruments Agricultural Products Catalog ® 5th HI HI HI HI HI HI HI HI HI HI 1230B pH electrode, gel filled, PEI body, BNC, 1 m cable 3230B ORP electrode, gel filled, PEI body, BNC, 1 m cable 7669/2W Temperature probe 76405 Electrode holder 7004L pH 4.01 buffer solution, 500 mL 7006L pH 6.86 buffer solution, 500 mL 7007L pH 7.01 buffer solution, 500 mL 7009L pH 9.18 buffer solution, 500 mL 7010L pH 10.01 buffer solution, 500 mL 70300L Electrode storage solution, 500 mL HI 8424NEW pH: -2.00 to 16.00; mV: ±699.9 to ±1999; Temperature: -10.0 to 120.0°C/-4.0 to 248.0°F pH: 0.01; mV: 0.1, 1; Temperature: 0.1°C/0.1°F pH: ±0.01; mV ±0.2, ±1; Temperature: ±0.4°C/±0.8°F Range ACCESSORIES Edition pH/mV/°C Meter with ATC and Automatic Calibration • Extended mV range for ORP • Push button calibration • Enhanced version of one our most popular meters! The HI 8424NEW portable pH meter is one of the most popular pH meters on the market. With the HOLD function, readings can be frozen on the display to be logged manually. Also, temperature can be displayed in °C or °F and users can enable or disable the Auto-off feature, the acoustic signal and the back-lit display. In addition, HI 8424NEW indicates on the display the buffer values used for the last calibration. With Great Products, Come Great Results.™ Portable Meters HI 993310 Direct Measurement of Soil Activity & Solution Conductivity • Measures EC in soil, irrigation water and fertilizer mixes • Easy to calibrate • Automatic temperature compensation SPECIFICATIONS HI 993310 Range EC: 0.00 to 19.99 mS/cm; activity: 0.00 to 1.00 Resolution EC: 0.01 mS/cm; activity: 0.01 Accuracy (@20°C/68°F) EC: ±2% F.S. (0 to 15.00 mS/cm; excluding probe error) Calibration Manual, 1 point Automatic, 0 to 50°C (32°F to 122°F), β=2%/°C Temp. Compensation Probes Now it is possible to use one instrument to accurately and quickly measure EC in many places where the fertilizer is mixed, such as in the irrigation water and directly in the soil. This meter is easy to operate and gives fast, accurate measurements. HI 993310 is equipped with an alarm LED that automatically turns on if the soil is too dry, or nutritive substances such as potassium or nitrogen are lacking. Also included in the meter is the ability to measure salt activity. HI 76305 for direct soil measurements with stainless steel body, conic tip, built-in temperature sensor and 1 m (3.3') cable (included). HI 76304 for EC measurements in solution with plastic body, built-in temperature sensor and 1 m (3.3') cable (included) Battery Type/Life 9V / approx. 100 hours of continuous use Environment 0 to 50°C (32 to 122°F); 95% RH non-condensing Dimensions 185 x 82 x 52 mm (7.3 x 3.2 x 2.0'') Weight 275 g (9.7 oz.) ORDERING INFORMATION HI 993310 is supplied complete with HI 76304 EC probe for solutions, HI 76305 stainless steel probe for direct soil measurements, HI 7051M soil preparation solution, HI 721319 ground auger, battery, rugged carrying case and instructions. ACCESSORIES HI HI HI HI HI HI HI HI 76305 Stainless steel probe for direct soil measurement 76304 EC probe for measurement of solution and soil sample 7030L 12880 μS/cm calibration solution, 500 mL 7031L 1413 μS/cm calibration solution, 500 mL 7051M Soil preparation solution 721319 Ground auger 710009 Shockproof rubber boot, blue 710010 Shockproof rubber boot, orange HI 99300 • HI 99301 EC/TDS/Temperature Meters • Measure EC/TDS/temperature with one probe • Automatic calibration • Automatic temperature compensation HI 99300 and HI 99301 are two innovative meters that combine measurements of conductivity, TDS (Total Dissolved Solids) and temperature. The housing is water-resistant and rated for IP 67 conditions. All settings and calibration data remain in memory even when changing batteries. SPECIFICATIONS Range ORDERING INFORMATION HI 99300 is supplied complete with HI 76306 probe with 1 m (3.3’) cable, batteries, rugged carrying case and instructions. HI 99301 is supplied complete with HI 76306 probe with 1 m (3.3’) cable, batteries, rugged carrying case and instructions. ACCESSORIES HI HI HI HI HI HI HI HI 76306 EC/TDS/temperature probe with 1 m (3.3’) cable 70030P 12880 μS/cm calibration solution, (25) 20 mL sachets 70031P 1413 μS/cm calibration solution, (25) 20 mL sachets 70032P 1382 ppm calibration solution, (25) 20 mL sachets 70442P 1500 ppm calibration solution, (25) 20 mL sachets 70038P 6.44 ppt calibration solution, (25) 20 mL sachets 710007 Shockproof rubber boot, blue 710008 Shockproof rubber boot, orange Resolution HI 99300 HI 99301 EC: 0 to 3999 μS/cm; TDS: 0 to 2000 ppm (mg/L); Temperature: 0.0 to 60.0°C/32.0 to 140.0°F EC: 0.00 to 20.00 mS/cm; TDS: 0.00 to 10.00 ppt (g/L); Temperature: 0.0 to 60.0°C/32.0 to 140.0°F EC: 1 μS/cm; TDS: 1 ppm (mg/L); Temperature: 0.1°C/0.1°F EC: 0.01 mS/cm; TDS: 0.01 ppt (g/L); Temperature: 0.1°C/0.1°F Accuracy (@20°C/68°F) EC/TDS: ±2% F.S.; Temperature: ±0.5°C/±1°F TDS Factor (CONV) Adjustable from 0.45 to 1.00 with 0.01 step (default 0.50) Calibration Temp. Compensation Probe Battery Type/Life Automatic, 1 point at 1382 ppm (CONV 0.5) or at 1500 ppm (CONV 0.7) or at 1413 μS/cm (others) Automatic, 1 point at 6.44 ppt (CONV 0.5) or at 9.02 ppt (CONV 0.7) or at 12880 μS/cm (others) Automatic, 0 to 60°C (32 to 140°F) with β adjustable from 0.0 to 2.4%/°C with 0.1% step HI 76306 EC/TDS/temperature, with DIN connector and 1 m (3.3’) cable (included) (4) 1.5V AAA / approx. 500 hours of continuous use Environment 0 to 50°C (32 to 122°F); RH max 100% Dimensions 143 x 80 x 38 mm (5.6 x 3.1 x 1.5'') Weight 210 g (7.4 oz.) www.hannainst.com/usa 15 Portable Meters HI 98360 EC/TDS/NaCl/°C Meter with Auto Endpoint • Waterproof • PC compatible • 4-ring probe HI 98360 is a rugged waterproof conductivity meter, which combines versatility and reliability with ease of use. This portable instrument is equipped with an auto-ranging feature and allows the user to measure EC and TDS with the resolution that best fits with the sample. The "Auto Endpoint" feature makes HI 98360 the ideal meter for field measurements: after entering this mode, the instrument will automatically freeze stable readings on the LCD. The included HI 76309/1.5 probe is a potentiometric 4-ring probe for EC/TDS and temperature measurements. The HI 76309/1.5 features a PVC body, stainless steel sensors and 1.5 m (4.9') screened cable. SPECIFICATIONS HI 98360 EC TDS NaCl Temperature 0.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (actual EC)* 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (actual TDS)* 0.0 to 400.0% 9.9 to 120.0°C** Resolution 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm 0.01 ppm (mg/L), 0.1 ppm (mg/L), 1 ppm (mg/L), 0.01 g/L, 0.1 g/L 0.1% 0.1°C Accuracy ±0.5% of reading ±0.5% of reading ±0.5% of reading ±0.4°C Range EC: Automatic, 1 point with 6 memorized values (84, 1413, 5000, 12880 and 11180 μS/cm); NaCl 1 point, with HI 7037 calibration solution (not included); Temperature: 2 point at 0 and 50°C (32 to 122°F) Calibration Temp. Compensation Automatic or manual, 0 to 60°C (32 to 140°F) (can be disabled to measure actual EC and TDS) Temp. Coefficient Adjustable from 0.00 to 6.00%/°C (EC and TDS only) TDS Conversion Factor Adjustable from 0.40 to 0.80 Data Logging Up to 250 samples Probe HI 76309/1.5 with 1.5 m (4.9’) cable (included) Power Supply (4) 1.5V AA batteries (included), approx. 200 hours of continuous use, or 12 Vdc input; auto-off after 5 minutes of non-use (can be disabled) Environment 0 to 50°C (32 to 122°F); 100% RH Dimensions 196 x 80 x 60 mm (7.7 x 3.1 x 2.4'') Weight 500 g (1.1 lb.) ORDERING INFORMATION * with temperature compensation function disabled HI 98360 is supplied with HI 76309/1.5 probe with 1.5 m (4.9’) cable, batteries, rugged carrying case and instructions. ** using the proper probe ACCESSORIES HI 76309/1.5 4-ring conductivity probe with 1.5 m (4.9’) cable HI 76310 4-ring conductivity probe with Pt sensor and 1 m (3.3’) cable HI 7030L 12880 μS/cm calibration solution, 500 mL 16 HI HI HI HI HI 7031L 1413 μS/cm calibration solution, 500 mL 7033L 84 μS/cm calibration solution, 500 mL 7034L 80000 μS/cm calibration solution, 500 mL 7035L 111800 μS/cm calibration solution, 500 mL 7039L 5000 μS/cm calibration solution, 500 mL HANNA instruments Agricultural Products Catalog ® 5th Edition HI HI HI HI HI 7037L 100% NaCl standard solution, 500 mL 710005 115 Vac/12 Vdc power adapter 710006 230 Vac/12 Vdc power adapter 92000 Windows® compatible application software 920011 Interface for PC connection With Great Products, Come Great Results.™ Portable Meters HI 9813 Series Waterproof pH/EC/TDS/°C Meters for Growers • Fast response probe • Available with °C display • Exclusive Clean & Cal feature (HI 9813-6) Order the HI 9813 according to your needs: HI 9813-0 allows you to measure pH, EC (conductivity) and TDS with just one instrument! The meter has a pH measurement range that covers the full spectrum. Suited for hydroponics, greenhouses, farming, and ground water applications. HI 9813-5 offers all of the features if the HI 9813 with the addition of temperature measurement in the °C scale. HI 9813-6 is the most complete model in the HI 9813 series. The HI 9813-6 includes all of the features of the previous models and HANNA’s new F.S.T. technology. With this special security system, if the meter encounters incorrect readings, the instrument doesn’t display values close to pH 7, but close to pH 4, making the problem clear to the user. To allow maximum confidence in your measurements, the meter is equipped with two LEDs and a “Check” button. When pressing this button, after immersing the electrode in the proper solution, HI 50021P (Cal-Check solution), one of the LED’s will light up to indicate the status of the meter. The green LED (“OK”) indicates the probe is working correctly, while the red LED (“C&C” Clean & Cal) indicates the electrode needs attention. SPECIFICATIONS Range HI 9813-0 pH: 0.0 to 14.0; EC: 0.00 to 4.00 mS/cm; TDS: 0 to 1999 ppm (mg/L) pH: 0.1; EC: 0.01 mS/cm; TDS: 1 ppm (mg/L); Temperature: 0.1°C pH: 0.1; EC: 0.01 mS/cm; TDS: 1 ppm (mg/L); Temperature: 0.1°C pH: ±0.1; EC/TDS: ±2% F.S. pH: ±0.1; EC/TDS: ±2% F.S.; Temperature: ±0.5°C pH: ±0.1; EC/TDS: ±2% F.S.; Temperature: ±0.5°C Calibration Manual at 1 point (all parameters except temperature) Temp. Compensation Automatic, 0 to 50°C (32 to 122°F) with ß=2%/°C (EC/TDS only) TDS Conversion Factor Probe HI 9813-6 pH: 0.1; EC: 0.01 mS/cm; TDS: 1 ppm (mg/L) Resolution Accuracy (@20°C/68°F) HI 9813-5 pH: 0.0 to 14.0; EC: 0.00 to 4.00 mS/cm; pH: 0.0 to 14.0; EC: 0.00 to 4.00 mS/cm; TDS: 0 to 1999 ppm (mg/L); Temperature: 0.0 to 60.0°C TDS: 0 to 1999 ppm (mg/L); Temperature: 0.0 to 60.0°C 0.56 to 0.72 ppm = 1 μS/cm HI 1285-0, pH/EC/TDS, 1 m cable (included) HI 1285-5, pH/EC/TDS/T, 1 m cable (included) Battery Type/Life (1) 9V / approximately 150 hours of continuous use Environment 0 to 50°C (32 to 122°F); 100% RH Dimensions 165 x 75 x 45 mm (6.9 x 2.9 x 1.8'') Weight 180 g (6.3 oz.) ORDERING INFORMATION ACCESSORIES HI 9813-0 is supplied complete with pH/EC/TDS probe HI 1285-0, 1 m cable, pH 7 calibration solution (1 x 20 mL), 1.41 mS/cm and 1500 ppm (1 each) calibration solution, cleaning solution (2 pcs.), blue protective case, battery and instructions. HI HI HI HI HI HI HI HI HI HI HI HI HI 9813-5 is supplied complete with pH/EC/TDS/T HI 1285-5 1 m cable, pH 7 calibration solution (1 x 20 mL), 1.41 mS/cm and 1500 ppm (1 each) calibration solution, cleaning solution (2 pcs.), blue protective case, battery and instructions. HI 9813-6 is supplied complete with pH/EC/TDS/T HI 1285-6 probe with 1 m (3.3’) cable, pH 7, 1.41 mS/cm and 1500 ppm calibration solution (20 mL each), cleaning solution (2 pcs), HI 50021 test solution (2 pcs), blue protective case, battery and instructions. HI 1285-6, pH/EC/TDS/T, with Clean & Cal, 1 m (3.3’) cable (included) 1285-6 pH/EC/TDS/T probe, with Clean & Cal, 1 m (3.3) cable 1285-5 pH/EC/TDS/T probe, 1 m (3.3’) cable 1285-0 pH/EC/TDS probe, 1 m (3.3’) cable 77100P pH 7 and 1413 μS/cm calibration solution (20) 20 mL sachets, 10 ea. 77200P pH 7 and 1500 ppm calibration solution (20) 20 mL sachets, 10 ea. 77400P pH 4 and 7 calibration solution (10) 20 mL sachets, 5 ea. 50021P Clean & Cal solution (25) 20 mL sachets 70300L Electrode storage solution, 500 mL 7061L Cleaning solution, 500 mL 710015 Shockproof rubber boot, blue 710016 Shockproof rubber boot, orange 710022 Blue protective case www.hannainst.com/usa 17 Portable Meters HI 991301 pH/EC/TDS/Temperature 4-in-1 Megameter • Waterproof • 4 parameters—1 probe! • Automatic calibration This multi-parameter instrument tests for 4 of the most important factors in the growing environment. Calibration is performed at the touch of a button with memorized pH and EC buffers. Accuracy is ensured with Automatic Temperature Compensation and the advanced sensor material which completely eliminates polarization and oxidation problems. Beta factor and TDS ratios are user-selectable as is the ability to read in °C or °F. SPECIFICATIONS Range ORDERING INFORMATION HI 991301 is supplied complete with pH/EC/TDS/T HI 1288 probe, with 1 m (3.3’) cable, batteries, rugged carrying case and instructions. ACCESSORIES HI HI HI HI HI HI HI HI HI Resolution Accuracy (@20°C/68°F) pH Calibration EC/TDS Calibration 1288 pH/EC/TDS/T probe 710007 Shockproof rubber boot, blue 710008 Shockproof rubber boot, orange 70030P 12880 μS calibration solution (25) 20 mL sachets 70038P 6.44 ppt calibration solution (25) 20 mL sachets 77100P 1413 μS/pH 7 calibration solution (20) 20 mL sachets, 10 ea. 77200P 1500 ppm/pH 7 calibration solution (20) 20 mL sachets, 10 ea. 77300P 1382 ppm/pH 7 calibration solution (20) 20 mL sachets, 10 ea. 77400P pH 4; pH 7 calibration solution (10) 20 mL sachets, 5 ea. HI 991301 pH: 0.00 to 14.00; EC: 0.00 to 20.00 mS/cm; TDS: 0.00 to 10.00 ppt (g/L); Temperature: 0.0 to 60.0°C or 32.0 to 140.0°F pH: 0.01; EC: 0.01 mS/cm; TDS: 0.01 ppt; Temperature: 0.1°C or 0.1°F pH: ±0.01; EC/TDS: ±2% F.S.; Temperature: ±0.5°C or ±1.0°F Automatic at 1 or 2 points with 2 sets of memorized standard buffers (pH 4.01/7.01/10.01 or pH 4.01/6.86/9.18) Automatic, 1 point at 6.44 ppt (CONV 0.5) or at 9.02 ppt (CONV 0.7) or at 12880 μS/cm (others) TDS Conv. Factor Selectable 0.45 to 1.00 with 0.01 increments (default 0.50) Temp. Compensation pH: automatic; EC/TDS: automatic, BETA (β) is adjustable from 0.0 to 2.4%/°C w/0.1 increments Probe HI 1288 pH/EC/TDS/T, DIN connector, 1 m (3.3’) cable (included) Battery Type/Life (4) 1.5V AAA/approx. 100 hrs of continuous use Environment Dimensions/Weight 0 to 50°C (32 to 122°F); 100% RH 150 x 80 x 36 mm (5.9 x 3.1 x 1.4”)/210g (7.4 oz.) HI 9811-0 • HI 9811-5 pH, Conductivity to 6000 μS/cm and Temperature • Water-resistant • 1 probe for all parameters! • 0.0 to 70.0°C temperature range (HI 9811-5) HI 9811-0 and HI 9811-5 are portable meters for field measurement of pH, conductivity and TDS. HI 9811-5 features additional temperature measurement in °C. These versatile instruments are ideal for use in agriculture. The rugged housing has been specifically designed to be easy to use in the field, while reducing the number of instruments required for water quality analysis. HI 9811-0 and HI 9811-5 are equipped with Automatic Temperature Compensation and BEPS (Battery Error Prevention System) which alerts the user when low batteries could affect the readings. SPECIFICATIONS Range Resolution Accuracy (@20°C/68°F) Calibration Temp. Compensation HI 9811-0 HI 9811-5 pH: 0.0 to 14.0; EC: 0 to 6000 μS/cm; pH: 0.0 to 14.0; EC: 0 to 6000 TDS: 0 to 3000 ppm (mg/L; μS/cm; TDS: 0 to 3000 ppm (mg/L) Temperature: 0.0 to 70.0°C pH: 0.1; EC: 10 μS/cm; pH: 0.1; EC: 10 μS/cm; TDS: 10 mg/L; TDS: 10 mg/L Temperature: 0.1°C pH: ±0.1; EC/TDS: ±2% F.S.; pH: ±0.1; EC/TDS: ±2% F.S. Temperature: ±0.5°C Manual at 1 point (all parameters except temperature) Automatic 0 to 50°C with ß = 2% /°C (EC/TDS only) TDS Conversion Factor 0.5 mg/L = 1 μS/cm HI 1285-0 pH/EC/TDS, 1 m cable (included) Probe HI 1285-5 pH/EC/TDS/T, 1 m cable (included) Battery Type/Life Environment (1) 9V / approximately 150 hours of continuous use 0 to 50°C (32 to 122°F); 100% RH Dimensions/Weight 165 x 75 x 45 mm (6.9 x 2.9 x 1.8'')/180 g (6.3 oz.) 18 HANNA instruments Agricultural Products Catalog ® 5th Edition ORDERING INFORMATION HI 9811-0 and HI 9811-5 are supplied complete with HI 1285-0 (-0) or HI 1285-5(-5) probe with 1 m (3.3’) cable, pH 7 calibration solution, 1382 ppm and 1413 μS/cm calibration solutions (1 each), cleaning solution (2 pcs), blue protective case, battery and instructions. ACCESSORIES HI 1285-0 pH/EC/TDS probe, 1 m (3.3’) cable HI 1285-5 pH/EC/TDS/T probe, 1 m (3.3’) cable HI 710015 Shockproof rubber boot, blue HI 710016 Shockproof rubber boot, orange HI 70300L Electrode storage solution, 500 mL HI 7061L Cleaning solution, 500 mL HI 77100P pH 7 and 1413 μS/cm calibration solution (20) 20 mL sachets, 10 ea. HI 77300P pH 7 and 1382 ppm calibration solution (20) 20 mL sachets, 10 ea. HI 77400P pH 4 and 7 calibration solution (10) 20 mL sachets, 5 ea. With Great Products, Come Great Results.™ Extended Range D.O. Meter • Water-resistant • 4 parameters—1 probe! • Automatic calibration The HI 9143 is designed for outdoor applications. Simple on-site calibration requires no chemical solutions. Just expose the probe to air and press the CAL button. In a few minutes, the meter is calibrated and ready to use. The HI 9143 measures and displays O2 from 0 to 300%, 0 to 45 mg/L and temperature from 0 to 50 °C. SPECIFICATIONS Range Resolution Accuracy (@20°C/68°F) HI 9143 O2: 0.00 to 45.00 mg/L; % Saturation O2: 0.0 to 300.0%; Temperature: 0.0 to 50.0°C O2: 0.01 mg/L; % Saturation O2: 0.1% F.S.; Temperature: 0.1°C O2: ±1.5% F.S.; % Saturation O2: 1.5% F.S.; Temperature: ±0.5°C Calibration Temp. Compensation Altitude Compensation Salinity Compensation Probe Battery Type/Life Automatic, in air, at 100% Automatic, 0 to 50°C (32°F to 122°F) 0 to 1900 m, 100 m (328') resolution 0 to 40 g/L, 1 g/L resolution HI 76407/4 polarographic, with 4 m (13') cable (included) (4)1.5V AA/approx. 200 hours of continuous use; auto-off after 4 hours of non-use; or input for 12 Vdc power adapter Environment Dimensions Weight ORDERING INFORMATION ACCESSORIES HI 9143 is supplied complete with D.O. probe HI 76407/4 with 4 m (13’) cable, 2 spare membranes, electrolyte solution HI 7041S (30 mL), batteries, rugged carrying case and instructions. HI HI HI HI HI 9142 Water-resistant D.O. Meter 0 to 50°C (32 to 122°F); 100% max RH 196 x 80 x 60 mm (7.7 x 3.1 x 2.4'') 500 g (1.1 lb.) 76407/4 D.O. Probe with 4 m (13’) cable 76407/10 D.O. Probe with 10 m (33’) cable 76407/20 D.O. Probe with 20 m (67’) cable 7041S Refilling electrolyte solution (30 mL) HI 710006 230 Vac/12 Vdc adapter HI 76407A/P Replacement membrane (5 pcs) HI 721317 Rugged carrying case • Rugged and built to last • Designed for field use • Simple-to-use Measurements in the field can subject instrumentation to the inclemency of weather. Cold, rain, snow and dust associated with use in the field, can damage a meter, rapidly deteriorating its performance and life. HI 9142 is a rugged, waterproof meter that solves these common problems of field use. It is very simple to use: calibration is performed with HI 7040 zero oxygen solution, while 100% calibration is done in air. There is no need to use chemical solutions or go through time consuming calibration procedures. The polarographic probe (HI 76407/4) will take measurements accurate to 0.3 ppm in minutes and is supplied with a 4 m (13') cable that allows measurements to be taken even in even hard to reach places. For applications that require longer probe cables, the HI 76407/10 and HI 76407/20 probes with a 10 m (33') or 20 m (67') cable are available. SPECIFICATIONS ORDERING INFORMATION Resolution HI 9142 is supplied complete with HI 76407/4 D.O. probe with 4 m (13’) cable, 2 spare membranes, HI 7041S electrolyte solution (30 mL), calibration screwdriver, batteries, rugged carrying case and instructions. ACCESSORIES HI HI HI HI 76407/4 D.O. Probe with 4 m (13’) cable 76407/10 D.O. Probe with 10 m (33’) cable 76407/20 D.O. Probe with 20 m (67’) cable 7040M Zero oxygen solution (230 mL) HI HI HI HI 7040L Zero oxygen solution (500 mL) 7041S Refilling electrolyte solution (30 mL) 76407A/P Replacement membrane (5 pcs) 721317 Rugged carrying case Range Accuracy (@20°C/68°F) Calibration Temp. Compensation HI 9142 0.0 to 19.9 mg/L 0.1 mg/L ±1.5% F.S. Manual at 1 or 2 points (zero and slope) Automatic, 0 to 30°C Probe HI 76407/4 polarographic, with 4 m (13') cable (included) Battery Type/Life (4)1.5V AA/approx. 500 hours of continuous use Environment Dimensions Weight 0 to 50°C (32 to 122°F); 100% max RH 196 x 80 x 60 mm (7.7 x 3.1 x 2.4'') 500 g (1.1 lb.) www.hannainst.com/usa 19 Portable Meters HI 9143 Portable Meters Shown with optional HI 710008 rubber boot HI 93640 HI 8564 Compact, Portable Thermohygrometer Relative Humidity & Temperature Meter • Large LCD • Dual-temperature range • Low-battery indicator • Quick response time • High accuracy • Displays temperature in °C and °F The HI 93640 is a compact, portable and versatile hygrometer with a convenient wrist strap so you can monitor relative humidity anywhere. The built-in thin-film capacitance sensor assures accurate humidity measurements from 5 to 95% RH with a resolution of 0.1%. SPECIFICATIONS SPECIFICATIONS HI 93640 Range RH: 5.0 to 95.0%; Temperature: 0.0 to 60.0°C (32 to 140°F) Resolution RH: 0.1%; Temperature: 0.1°C; 1°F RH: ±2%; Temperature: ±0.4°C; ±1°F (for 1 year, excluding probe error) Accuracy (@20°C/68°F) Battery Type/Life The HI 8564 portable, RH/ Temperature meter uses a membrane keypad to switch from RH readings to temperature in °C or °F. The quick response time and reliability of the meter makes it a valuable tool to the greenhouse professional. Range Resolution Accuracy (@20°C/68°F) RH Calibration (1) 9V AA/approx. 100 hours continuous use Environment 0 to 50°C (32 to 122°F); 98% max RH non-condensing Dimensions 190 x 80 x 38 mm (7.5 x 3.1 x 1.54'') Weight HI 8564 RH: 10.0 to 95.0%; Temperature: 0.0 to 60.0°C (32 to 140°F) RH Probe Battery Type/Life Environment Dimensions 200 g (7.1 lb.) RH: 0.1%; Temperature: 0.1°C; 1°F RH: ±2%; Temperature: ±0.4°C; ±1°F (for 1 year, excluding probe error) Manual 2 point through trimmer on RH probe HI 70601/2 with built-in temperature sensor and 2 m (6.6’) cable (included) (1) 9V AA/approx. 100 hours of continuous use 0 to 50°C (32 to 122°F); 98% max RH non-condensing 190 x 80 x 38 mm (7.5 x 3.1 x 1.54'') ORDERING INFORMATION Weight HI 93640 is supplied complete with probe sintered cap, battery and instructions. ORDERING INFORMATION ACCESSORIES HI 8564 is supplied complete with HI 70601/2 RH probe with internal temperature sensor and 2 m (6.6’) cable, battery and instructions. HI 710007 Blue shockproof rubber boot HI 710008 Orange shockproof rubber boot HI 710011 Probe sintered cap HI 710031 Rugged carrying case HI 7102 Calibration chamber HI 7111/P Spare saturation LiCl salts for low humidity calibration (15 g, 6 pcs) HI 7121/P Spare saturation NaCl salts for high humidity calibration (33 g, 6 pcs) HI 9065 Relative Humidity /Temperature Meter Professional Growers • • • • 200 g (7.1 lb.) ACCESSORIES HI HI HI HI 70601/2 RH probe, 2 m (6.6’) cable 70601/5 RH probe, 5 m (16.5’) cable 7101 Calibration chamber 7111/P Spare saturation LiCl salts for low humidity calibration (15 g, 6 pcs) HI 7121/P Spare saturation NaCl salts for high humidity calibration (33 g, 6 pcs) SPECIFICATIONS Range Water-resistant casing High accuracy Hold key Displays temperature in °C and °F Accuracy (@20°C/68°F) Resolution RH Calibration RH Probe Battery Type/Life Environment Dimensions Weight HI 710009 Blue shockproof rubber boot HI 710010 Orange shockproof rubber boot HI 710001 Soft carrying case HI 721316 Rugged carrying case HI 9065 RH: 5.0 to 95.0%; Temperature: 0.0 to 60.0°C (32 to 140°F) up to 105°C (302°F) with HI 765 temperature probe RH: ±2%; Temperature: ±0.4°C; ±1°F (for 1 year, excluding probe error) RH: 0.1%; Temperature: 0.1°C; 1°F Manual 2 point through trimmer on RH probe HI 70605/2 with built-in temperature sensor and 2 m (6.6’) cable (included) (4) 1.5V AA/approx. 500 hours of continuous use 0 to 50°C (32 to 122°F); 100% max RH 196 x 80 x 60 mm (7.7 x 3.1 x 2.4'') 500 g (1.1 lb.) ORDERING INFORMATION HI 9065 is supplied complete with HI 70605/2 RH probe with internal temperature sensor and 2 m (6.6’) cable, battery, rugged carrying case and instructions. ACCESSORIES HI HI HI HI 70605/2 RH probe, 2 m (6.6’) cable 70605/5 RH probe, 5 m (16.5’) cable 7101 Calibration chamber 7111/P Spare saturation LiCl salts for low humidity calibration (15 g, 6 pcs) HI 7121/P Spare saturation NaCl salts for high humidity calibration (33 g, 6 pcs) 20 HANNA instruments Agricultural Products Catalog ® 5th Edition HI 710009 Blue shockproof rubber boot HI 710010 Orange shockproof rubber boot HI 710001 Soft carrying case HI 721316 Rugged carrying case With Great Products, Come Great Results.™ Portable Meters HI 97500 Portable Lux Meter for Rapid Light Measurements in a Waterproof Case • • • • Three measurement ranges Light sensor attached to 1.5 meter coaxial cable Rugged, waterproof case Low-battery indicator The HI 97500 portable Lux Meter from HANNA instruments® has been designed for simplicity of use in taking rapid light measurements. The HI 97500 is provided with a light sensor connected by a flexible coaxial cable which allows remote, stable and optimum position measurement of light, without any interference of the operator. The meter makes it possible to choose among three measurement ranges by simply pressing the RANGE key. The HI 97500 Lux Meter is housed in a rugged waterproof case for trouble-free outdoor measurements. SPECIFICATIONS Range HI 97500 0.001 to 1.999 Klux; 0.01 to 19.99 Klux; 0.1 to 199.9 Klux Resolution 0.001 Klux; 0.01 Klux; 0.1 Klux Accuracy Sensor Battery Type/Life ORDERING INFORMATION ±6% of reading ±2 digits Human-eye-response silicon photodiode with 1.5 m coaxial cable (fixed) 9V AA/approx. 200 hours of continuous use; Auto-off after 7 minutes of non-use Environment 0 to 50°C (32 to 122°F); 100% RH Dimensions 164 x 76 x 45 mm (6.5 x 3.0 x 1.8'') HI 97500 is supplied with battery, protective case and instructions. Weight Light Intensity Plant Light Requirements Quality of light is very important in the workplace, schools, greenhouses and public buildings. Too little light (or luminous intensity) affects the quantity and quality of performance of both people and crops. HANNA's light meter uses special optic filters to match the spectral sensitivity of the human eye. Light provides the energy source needed for plants to manufacture food (photosynthesis). The amount of light is commonly measured in foot-candles (ft-c) or lux. Plants differ greatly in their light intensity requirements. Indoor plants are often classified by the amount of light necessary for growth: Luminous intensity is measured and reported in foot-candles (ft-c) or in lux (lx). Light meters are commonly referred to as lux meters. One lux is equal to one lumen per square meter and one foot-candle is equal to one lumen per square foot. To convert measurements use the following formulae: • Low (minimum 1.1 Klx, .8 to 2.1 preferred for good growth) • Medium (minimum 1.1 to 1.6 Klx, 2.1 to 5.4 preferred) • High (minimum 1.6 to 10.8 Klx, 5.4 to 10.8 preferred) • Very high (minimum 10.8 Klx, 10.8+ preferred) foot-candle = lux x 0.0929 lux = foot-candle x 10.764 HANNA's light measuring sensor is a photo diode that converts incident light into an electronic signal that is read and displayed on the meters LCD as Klx which is 1,000 lx. So multiply the reading by 92.9 to get the measurement in foot candles. Common Examples of Light Intensities Full Moon .001 Klx 1 lx .0929 ft-c Street Lighting .01 Klx 10 lx .929 ft-c Workspace Lighting .1 - 1 Klx 100 - 1,000 lx 9.29 - 92.9 ft-c Surgery Lighting 10 Klx 10,000 lx 929 ft-c Sunshine 100 Klx 100,000 lx 9,290 ft-c 180 g (6.3 oz.) About 1.1 Klx for 12 hours per day are necessary simply to maintain plant quality for one year and at least 2.1 Klx for 12 hours per day are necessary for foliage plants to manifest any benefit from fertilization. While lack of sufficient light results in poor plant growth, too much light can also be harmful. Shade plants cannot tolerate excessively high light levels. When a plant receives too much direct light, the leaves bleach or scald, sometimes dying. This often happens after moving a plant outdoors in direct light. Any changes in light intensity should be gradual. www.hannainst.com/usa 21 Chemical Test Kits HI 83900 Suction Lysimeter • Perfect companion to the HI 83215 • Monitor soil composition right at the roots • Easy to use Available in 3 Lengths The HI 83900 suction lysimeter is built with a porous ceramic cap connected to a transparent tube for soil solution extraction. A rubber capillary is inserted in the tube passing through a rubber cap and reaching the ceramic tip. The HI 83900 series lysimeter is an ideal tool for collecting soil solution samples and then perform quantitative chemical analysis. In this way the operator can easily monitor the level of nutrients, such as ammonia, nitrate, phosphorous and potassium, sulphate, calcium, magnesium. HI 83900-30 30 cm (0.98’) HI 83900-60 60 cm (1.97’) The ceramic tip of the lysimeter can be used in all types of soil, and it is made of sinterized material that does not react with nutrient elements. The soil solution, therefore, is not affected by the chemical composition of the ceramic cap, and the test results are always precise and reliable. HI 83900-90 90 cm (2.95’) 1. Rubber cap 2. Soil solution sampler tube 3. Porous ceramic tip 4. 30 mL syringe (pump) 5. Rubber suction capillary 6. Finger clamp The HI 83900 allows to extract a solution from the soil by creating a vacuum (negative pressure or suction) inside the sampler tube, that exceeds the soil water tension. This will establish an hydraulic gradient for the solution to flow through the porous ceramic cap and into the lysimeter tube. Typically, a vacuum of about -60 cb (centibar) should be drawn. For better monitoring the soil solution composition throughout an entire growth period of crops, at least two lysimeters should be installed in the root zone of a representative plant, one at the upper part and the other in the lower part of the root zone. For better accuracy and repeatability of results, it is recommended to replicate the above described installation in at least two more locations. Use in conjuntion with our our HI 83215 on the opposite page. 22 ORDERING INFORMATION HI 83900-30 is comprised of 30 cm (0.98’) tube sampler tube ending with porous ceramic tip, capillary rubber tube with rubber cap and finger clamp, cleaning solution stater kit (120 mL bottle), 30 mL syringe and instruction manual. HI 83900-60 is comprised of 60 cm (1.97’) tube sampler tube ending with porous ceramic tip, capillary rubber tube with rubber cap and finger clamp, cleaning solution stater kit (120 mL bottle), 30 mL syringe and instruction manual. HI 83900-90 is comprised of 90 cm (2.95’) tube sampler tube ending with porous ceramic tip, capillary rubber tube with rubber cap and finger clamp, cleaning solution stater kit (120 mL bottle), 30 mL syringe and instruction manual. ACCESSORIES HI 83900-25 Cleaning solution kit, 500 mL HANNA instruments Agricultural Products Catalog ® 5th Edition With Great Products, Come Great Results.™ Bench Photometers HI 83215 Grow Master Nitrogen, Phosphorus, Potassium and Ammonia Meter • Accurate • 4 parameters in 1 meter • Three ranges for each parameter • Easy to use • Economical tests HI 83215 is a practical instrument made to measure nutrients commonly present in fertilizer-enriched solutions. This convenient photometer measures ammonia, phosphorus, nitrate and potassium in three distinct ranges of low, medium and high concentrations. This way accuracy is maximized for each nutrient and for every concentration. Thanks to the low cost per test and simplicity of operation, you no longer need to send off your samples and wait for the results to come back. Using the HI 83215, you can test the presence and strength of nutrients right on the spot. This can translate itself into a substantial savings and improved yield. HI 83215 has been engineered to run on battery power as well as the mains. The HI 83215 comes complete with a 9-volt battery and a 12 VDC adapter. Add to this the unit’s lightweight and you have a bench/portable meter that is just at home in the field as in the horticulturist’s lab. PARAMETER SPECIFICATIONS Test Ammonia LR* Ammonia MR* Ammonia HR* Nitrate LR Nitrate MR Nitrate HR Phosphorus LR Phosphorus MR Phosphorus HR Potassium LR Potassium MR Potassium HR GENERAL SPECIFICATIONS Light Source Light Detector Power Supply Auto-off Environment Dimensions Weight HI 83215 Range 0.0 to 10.0 mg/L (ppm) 0.0 to 50.0 mg/L (ppm) 0 to 100 mg/L (ppm) 0.0 to 30.0 mg/L (ppm) 0 to 150 mg/L (ppm) 0 to 300 mg/L (ppm) 0.0 to 10.0 mg/L (ppm) 0.0 to 50.0 mg/L (ppm) 0 to 100 mg/L (ppm) 0.0 to 20.0 mg/L (ppm) 10 to 100 mg/L (ppm) 20 to 200 mg/L (ppm) Method Nessler Nessler Nessler Cadmium Reduction Cadmium Reduction Cadmium Reduction Amino Acid Amino Acid Amino Acid Turbidimetric Turbidimetric Turbidimetric HI 83215 3 tungsten lamps with narrow band interference filter 420/525/610 nm 4 Silicon Photocells (2) 9V batteries or 12 VDC adapter After 10 minutes of non-use 0 to 50°C (32 to 122°F); RH max 95% non-condensing 230 x 165 x 70 mm 640 g Reagents** HI 93715-01 HI 93715-01 HI 93715-01 HI 93728-01 HI 93728-01 HI 93728-01 HI 93706-01 HI 93706-01 HI 93706-01 HI 93750-01 HI 93750-01 HI 93750-01 * LR = Low Range MR = Medium Range HR = High Range **All reagents with -01 final code are for 100 tests. ORDERING INFORMATION ACCESSORIES HI 83215 is supplied complete with 4 measuring cuvets, batteries, 12 Vdc adapter and instructions. HI 83215K kit includes accessories for HI 83215: rugged carrying case, 100 mL and 170 mL beaker, 60 mL and 5 mL syringes, 1 filter-holder and 25 filters, 100 mL cylinder, demineralizer bottle, 2 pipettes, 1.5 mL spoon and active carbon for 50 tests HI 731318 Tissue for wiping cuvets (4) HI 731321 Spare measurement cuvets (4) HI 731325 Cap for cuvets (4) HI 83900-30 Lysimeter with 30 cm (0.98’) tube HI 83900-60 Lysimeter with 60 cm (1.97’) tube HI 83900-90 Lysimeter with 90 cm (2.95’) tube Plant Nutrition The three elements that are most needed by plants are nitrogen (N), phosphorous (P) and potassium (K). This is the reason why they are called macronutrients and should be given to plants. Nitrogen is indispensable for the plant’s life and is a key factor in fertilization. Nitrogen allows the development of the vegetative activity of the plant, in particular, causes lengthening of trunks and sprouts and increases the production of foliage and fruits. An excess of nitrogen weakens the plants’ structure creating an unbalanced relationship between the leaves and the stalks. In addition, the plant becomes less resistant to diseases. Phosphorous is an important element in the composition of DNA and RNA, the regulators of the energetic exchange (ATP & ADP), as well as the reserve substances in seeds and bulbs. It contributes to the formation of buds, roots, blooming, and lignification. A lack of phosphorous results in: stifling of plant, slow growth, a reduction of production, smaller fruits and a lower expansion of the roots. Even if Potassium is not a constituent of important compounds, it plays a remarkable role in many physiological activities like the control of cellular turgor and the accumulation of carbohydrates. It increases the size of fruits, their flavor, as well as yielding a positive effect on the color and fragrance of flowers. Potassium also makes plants more resistant to disease. www.hannainst.com/usa 23 Ion Specific Photometers HI 95771 Chlorine Ultra High Range Ion Selective Meter • • • • The HI 95771 displays the last time calibration was performed so you may schedule routine calibrations - ideal for ISO and Good Laboratory Practice environments. 0 to 500 mg/L Perfect for fruit and vegetable washing CAL CHECK™ calibration and verification Simple to use HI 95771 is a photometer developed to check chlorine dosing in disinfection processes with high concentrations of chlorine. Thanks to the extended range from 0 to 500 ppm, it is ideal for the food industry, such as in fruit and vegetable washing. HI 95771 also offers an additional range (0.00 to 5.00 ppm) for accurate measurements at lower values, to help control the chlorine level before discharging the treated water. SPECIFICATIONS ORDERING INFORMATION HI 95771 is supplied complete with 2 measuring cuvets, 9V battery and instructions. HI 95771C kit includes the above HI 95771, rugged carrying case, tissue for wiping cuvets and Cal CheckTM standard. ACCESSORIES HI 95771-01 Reagents for 100 Chlorine Ultra High Range tests HI 95771-03 Reagents for 300 Chlorine Ultra High Range tests HI 95771-11 CAL CHECK™ standard cuvets (1 set) HI 95771 ULTRA HR METER Range Resolution Precision Light Source Light Detector Power Supply 0 to 500 mg/L 1 mg/L (10 mg/L above 200 mg/L) ±2 mg/L to 100 mg/L Tungsten lamp with narrow band interference filter @ 525 nm Silicon Photocell (1) 9V battery Auto-off After 10 min of non-use in measure mode; after 1 hour of non-use in calibration mode Environment Dimensions Weight Method 0 to 50°C (32 to 122°F); RH max 95% non-condensing 180 x 83 x 46 mm (7.1 x 3.3 x 1.8”) 290 g (10 oz.) Adaptation of USEPA 330.5 Method and Standard Methods 4500-Cl “Peace of mind.” When performing measurements, you need to know that the instrument you are using is right on. With HANNA’s exclusive CAL CHECK™ feature you can now rest assured. With HANNA’s exclusive CAL CHECK™ validation function users are able to verify the performance of the instrument at any time. Taking just a few short steps, the validation procedure is extremely user friendly and ensures that the meter is properly calibrated. Just use the exclusive HANNA ready-made, NiST traceable standards to verify the performance of the instrument and recalibrate if necessary. All instruments are factory calibrated and the electronic and optical design minimizes the need for frequent calibration. HI 95734 HI 95721 Free and Total Chlorine Meter with CAL CHECK™ Iron Meter with CAL CHECK™ SPECIFICATIONS Range SPECIFICATIONS HI 95734 HI 95721 Range F: 0.00 to 10.00 mg/L; T: 0.00 to 10.00 mg/L 0.00 to 5.00 mg/L Resolution 0.01 mg/L (0.10 mg/L above 3.50 mg/L) Resolution 0.01 mg/L Precision ±0.06 mg/L to 3.00 mg/L Precision ±0.01 mg/L to 1.50 mg/L Adaptation of USEPA 330.5 Method and Standard Methods 4500-Cl Method Method Adaptation of USEPA 315B Method and Standard Methods 3500-Fe B REAGENTS REAGENTS HI 93734-01 Powder reagents for 100 tests (Free or Total Chlorine) HI 93734-03 Powder reagents for 300 tests (Free or Total Chlorine) HI 95734-11 Cal CheckTM standard cuvets HI 93721-01 Reagent kit for 100 tests HI 93721-03 Reagent kit for 300 tests HI 95721-11 Cal CheckTM standard 24 HANNA instruments Agricultural Products Catalog ® 5th Edition ORDERING INFORMATION HI 95717 HI 95706 Phosphate Meter with CAL CHECK™ Phosphorus Meter with CAL CHECK™ HI 95XXX series are supplied with cuvet(s), 9V battery and instructions. ACCESSORIES HI 710009 HI 710010 HI 721310 HI 731318 HI 731331 HI 731335 HI 93703-50 Blue rubber boot Orange rubber boot 9V battery (10 pcs) Tissue for wiping cuvets (4) Glass cuvets (4) Caps for cuvets (4 pcs) Cuvet cleaning solution (250 mL) GENERAL SPECIFICATIONS HI 95XXX Series Light Source SPECIFICATIONS HI 95717 0.0 to 30.0 mg/L (as PO43-) Range SPECIFICATIONS Range HI 95706 0.0 to 15.0 mg/L (as P) Resolution 0.1 mg/L Resolution 0.1 mg/L Precision ±0.5 mg/L to 12.0 mg/L Precision ±0.2 mg/L to 6.0 mg/L Method Adaptation of Amino Acid Method to the Standard Methods for the Examination of Water and Wastewater Adaptation of Amino Acid Method to the Standard Methods for the Examination of Water and Wastewater Method REAGENTS HI 95717-11 Cal CheckTM standard for HI 93717-01 Reagents for 100 tests HI 93717-03 Reagents for 300 tests HI 95706-11 Cal CheckTM standard for HI 93706-01 Reagents for 100 tests HI 93706-03 Reagents for 300 tests • • • • • Single and Dual Parameter Ion Specific Meters without CAL CHECK™ SPECIFICATIONS Light Detector Battery Life Auto-off Environment Dimensions Weight Dimensions Weight 180 x 83 x 46 mm 290 g (10 oz.) HI 93XXX Series 0-150 mg/L (ppm)Mg 0-400 mg/L (ppm) Ca Calmagite/470 nm Oxalate GENERAL SPECIFICATIONS HI 93XXX Series Light Source 0 to 50°C (32 to 122°F); RH max 95% non-condensing Lightweight and portable Quick and simple to use Long battery life Lab grade accuracy Economical tests Test & (Code) Range Method/Light Source Wavelength Accuracy (@20°C/68°F) Ammonia HR* (HI 93733) 0.0-50.0 mg/L (ppm) Nessler/470 nm** ±0.5 mg/L ±5% of reading Chlorine, Free & Total (HI 93734) 0.00-9.99 mg/L (ppm) (F. & T.) DPD/555 nm ±0.03 mg/L ±3% of reading Copper HR (HI 93702) 0.00-5.00 mg/L (ppm) Bicinchoninate/555 nm ±0.02 mg/L ±4% of reading Iron HR (HI 93721) 0.00-5.00 mg/L (ppm) Phenantroline/470 nm ±0.04 mg/L ±2% of reading Manganese HR (HI 93709) 0.0-20.0 mg/L (ppm) Periodate Oxidation/555 nm ±0.2 mg/L ±3% of reading Nickel LR* (HI 93740) 0.000-1.000 mg/L (ppm) PAN/555 nm ±0.010 mg/L ±5% of reading Nitrate (HI 93728) 0.0-30.0 mg/L (ppm) Cadmium Reduction/555 nm ±0.5 mg/L ±10% of reading Nitrite HR (HI 93708) 0-150 mg/L (ppm) Ferrous Sulfate/ 585 nm ±4 mg/L ±4% of reading Oxygen, Dissolved (HI 93732N) 0.0-10.0 mg/L (ppm) Modified Winkler/470 nm ±0.2 mg/L ±3% of reading Phosphate HR (HI 93717) 0.0-30.0 mg/L (ppm) Amino Acid/470 nm ±1 mg/L ±4% of reading Phosphorus (HI 93706) 0.0-15.0 mg/L (ppm) Amino Acid/470 nm ±0.3 mg/L ±4% of reading Potassium (HI 93750) 0.00-50.0 mg/L (ppm) Turbidimetric/470 nm ±1 mg/L ±5% of reading Sulfate (HI 93751) 0-150 mg/L (ppm) Turbidimetric/470 nm ±1 mg/L ±5% of reading Zinc (HI 93731) 0.00-3.00 mg/L (ppm) Zincon/585 nm ±0.03 mg/L ±3% of reading Calcium and Magnesium HR (HI 93752) Environment * nanometers REAGENTS HI 93XXX Series Light Detector Battery Life Auto-off Tungsten lamp with narrow band interference filter @ 525 nm* Silicon Photocell (1) 9V battery After 10 minutes of non-use * LR = Low Range HR = High Range LED (light Emitting Diode) Silicon Photocell 9V battery After 10 minutes of non-use 0 to 50°C (32 to 122°F); RH max 95% non-condensing 180 x 83 x 46 mm 290 g (10 oz.) ** nanometers ±3 mg/L ±3% of reading ±10 mg/L ±5% of reading ORDERING INFORMATION HI 93XXX series are supplied with cuvet(s), 9V battery and instructions. REAGENTS HI HI HI HI HI HI HI HI HI HI HI HI HI HI HI (100 tests ea. unless otherwise noted) 93733-01 (HR) Ammonia 93734-01 Free & total Chlorine 93702-01 (HR) Copper 93721-01 (HR) Iron 93709-01 (HR) Manganese 93740-01 (LR) Nickel (50 tests) 93728-01 Nitrate 93708-01 (HR) Nitrite 93732-01 Dissolved Oxygen 93717-01 (HR) Phosphate 93706-01 Phosphorus 93750-01 Potassium 93751-01 Sulfate 93731-01 Zinc 93752-01 (HR) Magnesium and Calcium www.hannainst.com/usa 25 Ion Specific Photometers With Great Products, Come Great Results.™ Monitoring Systems HI 991401 pH/Temperature Monitor Featuring a Large, Backlit LCD • • • • Waterproof Stability indicator Extra-large display 12 VDC power supply Dual-level Backlit LCD! The waterproof pH indicator HI 991401 has been designed to meet the grower's need for equipment suited to the aggressive environments found in agricultural and hydroponics applications. Measurements are highly accurate and can be verified with one or two point calibration. Low batteries and battery changes are no longer a problem thanks to a 12 VDC power supply included with the meter. The electrode is interchangeable and has been specially designed to address the needs of growers. Its design guarantees greater clogging resistance in fertilizer solutions with high concentrations of phosphate, nitrate, etc. This is a major improvement ensuring longer life for your electrode! SPECIFICATIONS Range Resolution Accuracy (@20°C/68°F) pH Calibration Temperature Compensation Probes Power Supply HI 991401 pH: 0.0 to 14.0; Temperature: 0.0 to 60.0°C (32.0 to 140.0°F) pH: 0.1; Temperature: 0.1°C (0.1°F) pH: ±0.1; Temperature: ±0.5°C (±1°F) Automatic 1 or 2 point with 2 sets of memorized buffers (pH 4.01/7.01/10.01 or pH 4.01/6.86/9.18) Automatic HI 1293D pH electrode (incl.) and HI 1294 temperature probe (incl.) 12 VDC adapter (included) 12 Input Impedance 10 Ohm Battery Life Environment Dimensions Weight (meter only) Approx. 2000 hours of continuous use 0 to 50°C (32 to 122°F); max. 95% RH 160 x 105 x 31 mm (6.3 x 4.1 x 1.2”) 190 g (6.7 oz) ORDERING INFORMATION HI 991401 is supplied complete with HI 1293D pH electrode, fixed temperature probe, pH 4 and pH 7 calibration solutions (20 mL each), 12 Vdc adapter and instructions. ACCESSORIES HI HI HI HI HI HI 7004M pH 4.01 calibration solution, 250 mL 7007M pH 7.01 calibration solution, 250 mL 7010M pH 10.01 calibration solution, 250 mL 77400P pH 4 and pH 7 sachets (10) 20 mL sachets, 5 ea. 70300M Electrode storage solution, 250 mL 7061M Electrode cleaning solution, 250 mL HI 981401N pH Indicator with Large LCD & Water Resistant Casing The HI 981401N has been designed to meet the grower's need for equipment suited to the aggressive environments found in agricultural and hydroponics applications. The housing features a molded eye which allows installation right above the sample to be monitored. The electrode is interchangeable and the connector is well-protected behind a waterproof sheath. The meter is supplied with a stainless steel probe, preventing potential grounding problems and ensuring extended electrode life. The gel-filled pH electrode guarantees greater clogging resistance in fertilizer solutions with high concentrations of phosphate, nitrate, etc. SPECIFICATIONS HI 981401N Range 0.0 to 14.0 pH Resolution Accuracy (@20°C/68°F) pH Calibration pH Electrode Power Supply Input Impedance Environment Dimensions (meter only) Weight ORDERING INFORMATION ACCESSORIES HI 981401N is supplied complete with HI 1286 pH electrode, 12 Vdc adapter, HI 1283 stainless steel grounding bar, pH 4 and pH 7 calibration solutions (20 mL each), calibration screwdriver and instructions. HI 7004M pH 4.01 calibration solution, 250 mL HI 7007M pH 7.01 calibration solution, 250 mL HI 7010M pH 10.01 calibration solution, 250 mL 26 HANNA instruments Agricultural Products Catalog ® 5th Edition 0.1 pH ±0.2 pH Manual 1 point at pH 4 and 7 HI 1286 plastic body, double junc., PTFE membrane, with 2 m (6.6’) cable & BNC conn. (incl.) 12 VDC adapter (included) 1012 Ohm 0 to 50°C ; max. 100% RH 86 x 110 x 43 mm (3.4 x 4.3 x 1.7”) 150 g (5.3 oz) HI 77400P pH 4 and 7 sachets (10) 20 mL sachets, 5 ea. HI 70300M Electrode storage solution, 250 mL HI 7061M Electrode cleaning solution, 250 mL With Great Products, Come Great Results.™ ® EC/TDS/Temperature Monitors with a Large Backlit LCD • Waterproof • Adjustable TDS ratio • Adjustable β Monitoring Systems HI 993301 • HI 993302 Dual-level Backlit LCD! • Extra-large display • 12 VDC adapter The waterproof EC/TDS indicators HI 993301 and HI 993302 have been designed to meet the Grower's need for equipment suited to the aggressive environments found in agricultural and hydroponics applications. At startup, HI 993301 and HI 993302 perform a self-check to assure proper working condition. These powerful instruments also feature a stability indicator and hold feature to prompt the user when to take the reading and freeze the display for easy and accurate recording. Calibration and temperature compensation is automatic, while the EC/TDS conversion factor and temperature coefficient factor (β) are user adjustable for application specific measurements. SPECIFICATIONS HI 993301 HI 993302 EC: 0 to 3999 μS/cm; TDS: 0 to 2000 ppm; Temperature: 0.0 to 60.0°C or 32.0 to 140.0°F EC: 0.00 to 20.00 mS/cm; TDS: 0.00 to 10.00 ppt; Temperature: 0.0 to 60.0°C or 32.0 to 140.0°F EC: 1 μS/cm; TDS: 1 ppm; Temperature: 0.1°C or 0.1°F EC: 0.01 mS/cm; TDS: 0.01 ppt; Temperature: 0.1°C or 0.1°F Accuracy (@20°C/68°F) EC: ±2% F.S.; TDS: ±2% F.S.; Temperature: ±0.5°C or ±1°F EC: ±2% F.S.; TDS: ±2% F.S.; Temperature: ±0.5°C or ±1°F EC/TDS Calibration Automatic 1 point at 1413 μS/cm Automatic 1 point at 12.88 mS/cm Range Resolution EC/TDS Conv. Factor Adjustable from 0.45 to 1.00 Probe Temp. Compensation HI 7630 (included) Automatic, BETA (β) is adjustable from 0.0 to 2.4%/°C Power Supply 12 VDC adapter (included) Environment 0 to 50°C (32 to 122°F); max 95% RH Dimensions 160 x 105 x 31 mm (6.3 x 4.1 x 1.2”) Weight (meter only) 190 g (6.7 oz.) ORDERING INFORMATION HI 993301 is supplied complete with HI 7630 EC probe, 1413 μS/cm calibration solution (20 mL), 12 Vdc adapter and instructions. HI 993302 is supplied complete with HI 7630 EC probe, 12.88 mS/cm calibration solution (20 mL), 12 Vdc adapter and instructions. ACCESSORIES HI HI HI HI HI HI HI HI 7030M 12.88 mS/cm calibration solution, 250 m 70030P 12.88 mS/cm calibration solution, (25) 20 mL sachets 7031M 1413 μS/cm calibration solution, 250 mL 70031P 1413 μS/cm calibration solution, (25) 20 mL sachets 7032M 1382 ppm calibration solution, 250 mL 70032P 1382 ppm calibration solution, (25) 20 mL sachets 7038M 6.44 ppt, calibration solution, 250 mL 70038P 6.44 ppt calibration solution, (25) 20 mL sachets HI 983302N ® EC Monitor Featuring a Large LCD & Water Resistant Casing The GRO’CHEK® EC monitor has been upgraded with a large, easy-to-read LCD. The HI 983302N’s waterproof casing guarantees operation after accidental water exposure. The professional EC electrode gives accurate results every time. SPECIFICATIONS HI 983302N Range Resolution Accuracy (@20°C/68°F) 0.00 to 9.99 mS.cm 0.01 mS.cm ±0.2% F.S. Calibration Temperature Comp. Probe Power Supply Input Impedance Environment Dimensions (meter only) Weight Manual 1 point through trimmer Automatic, 5 to 50°C (41 to 122°F) with β=2%/°C HI 7632 with 2 m (6.6’) cable (included) 12 VDC adapter (included) 1012 Ohm 0 to 50°C (32 to 122°F); max. 100% RH 86 x 110 x 43 mm (3.4 x 4.3 x 1.7”) 215 g (7.6 oz) ORDERING INFORMATION TDS Versions Available HI 983301N w/0.7 conv. fac. HI 983301N/5 w/0.5 conv. fac. HI 983302N is supplied with HI 7632 probe, 12 Vdc adapter, 1413 μ/cm calibration solution (20 mL), calibration screwdriver and instructions. ACCESSORIES HI 70031P 1413 μS/cm calibration solution, (25) 20 mL sachets www.hannainst.com/usa 27 Monitoring Systems HI 983304 Water-Resistant Conductivity Meter for Demineralized Water with Visual Alarm HI 983304 is specifically designed for use in demineralized and deionized water. When placed at the output of any demineralization system, the visual alarm will be activated as soon as the demineralizing equipment is exhausted. This exclusive feature will ensure maximum system efficiency with minimum investment. The meter measures from 0 to 19.99 μS/cm. and has a built-in 3½-digit LCD. HI 983304 is supplied with an HI 7631/2 direct 2-pin probe with a 2 m (6.6') cable and a ½" thread for flowthru mounting. This probe is also equipped with a temperature sensor to automatically compensate measurements against temperature changes from 5 to 50°C (41 to 122°F). When operating in the measurement mode, HI 983304’s red LED will alert the user as soon as the reading is 1 μS/cm over the setpoint. ORDERING INFORMATION HI 983304 is supplied complete with HI 7631/2 probe, calibration screwdriver, 12 Vdc adapter and instructions. SPECIFICATIONS HI 983304 Range Resolution Accuracy (@20°C/68°F) Calibration Temperature Compensation Setpoint Alarm EC Probe Power Supply Environment Dimensions Weight 0.00 to 19.99 μS/cm 0.01 μS/cm ±2% F. S. Manual, 1 point through trimmer Automatic, 5 to 50°C (41 to 122°F) with ß=2.4%/°C 1.00 to 5.00 μS/cm LED blinks when the measured valueis higher than 1.00 μS/cm of the setpoint HI 7631/2 with 2 m (6.6’) cable and ½" thread for in-line installation (incl.) 12 Vdc adapter (included) 0 to 50°C (32 to 122°F); RH max 100% 86 x 110 x 43 mm (3.4 x 4.3 x 1.7’’) 215 g (7.6 oz.) HI 983303 • HI 983306 • HI 983307 • HI 983308 Water-Resistant EC/TDS Meters with Visual Alarm Water-resistant conductivity/TDS meters are HANNA instruments®‘ reply to requests of accurate process monitoring at highly affordable costs with low maintenance. Four different models are available. These EC and SPECIFICATIONS HI 983303 Range Resolution Accuracy (@20°C/68°F) Calibration Calibration Solution Temp. Compensation Set Point 0 to 1990 μS/cm 10 μS/cm Alarm Probe (included) Power Supply Environment Dimensions Weight TDS meters can be installed anywhere quickly and easily with the casings molded hook. The specially designed casing is stable and will not roll off a table. The 12 Vdc power supply allows continuous monitoring over extended periods of time. HI 983306 ORDERING INFORMATION ACCESSORIES HI 983303 is supplied complete with HI 7634/2 probe, 12 Vdc adapter, 1413 μS/cm calibration solution (20 mL), screwdriver and instructions. HI HI HI HI HI 983306 is supplied complete with HI 7634/2 probe, 12 Vdc adapter, 1382 ppm calibration solution (20 mL), screwdriver and instructions. HI 983307 is supplied complete with HI 7632/2 probe, 12 Vdc adapter, 5000 μS/cm calibration solution (20 mL), screwdriver and instructions. HI 983308 is supplied complete HI 7632/2 probe, 12 Vdc adapter, 6.44 ppt calibration solution (20 mL), screwdriver and instructions. 28 HANNA instruments Agricultural Products Catalog ® HI 983307 HI 983308 0 to 1990 ppm (mg/L) 0.00 to 9.99 mS/cm 0.00 to 9.99 ppt (g/L) 10 ppm 0.01 mS/cm 0.01 ppt ±2% F. S. Manual, 1 point, through trimmer HI 70031P HI 70032P HI 70039P HI 70038P Automatic, 5 to 50°C (41 to 122°F) with ß=2%/°C 200 to 1600 μS/cm 200 to 1600 ppm 0.70 to 3.50 mS/cm 0.70 to 3.50 ppt red LED blinks when measured value differs from setpoint more than: +100 μS/cm ±100 ppm ±0.2 mS/cm ±0.2 ppt HI 7634/2 HI 7634/2 HI 7632/2 HI 7632/2 all probes are provided with 2 m (6.6’) cable and ½" thread for in-line installation 12 Vdc adapter (included) 0 to 50°C (32 to 122°F); RH max 100% 86 x 110 x 43 mm (3.4 x 4.3 x 1.7’’) 215 g (7.6 oz.) 5th Edition 70031P 1413 μS/cm calibration solution, (25) 20 mL sachets 70032P 1382 ppm calibration solution, (25) 20 mL sachets 70039P 5.00 mS/cm calibration solution, (25) 20 mL sachets 70038P 6.44 ppt calibration solution, (25) 20 mL sachets With Great Products, Come Great Results.™ Monitoring Systems HI 991404 • HI 991405 Combo pH, EC/TDS and Temperature Monitor with Large Backlit LCD • Waterproof • Adjustable TDS ratio • Adjustable β • Stability indicator • Extra-large display • 12 VDC power supply The Combo HI 991404 and HI 991405 series are designed for continuous, high accuracy pH, EC/TDS and temperature measurements. These microprocessor indicators continuously monitor the three most important nutrient parameters in hydroponics, greenhouses and horticultural applications with a single instrument. These indicators feature a large, dual-level, back-lit LCD to give you instantaneous readings of pH, EC or TDS and temperature, even from a distance. At startup, these indicators perform a self-check to assure proper working condition. HI 991404 and HI 991405 also have a stability indicator and hold feature to prompt the user when to take the reading and freezes the display for easy and accurate recording. These instruments are supplied with an advanced, non-clogging double junction pH electrode and a rugged conductivity probe that will withstand even the most aggressive environments. SPECIFICATIONS HI 991404 HI 991405 Range pH: 0.00 to 14.00; EC: 0 to 3999 μS/cm; pH: 0.00 to 14.00; EC: 0.00 to 20.00 mS/cm; TDS: 0 to 2000 ppm; Temperature: TDS: 0.00 to 10.00 ppt; Temperature: 0.0 0.0 to 60.0°C or 32.0 to 140.0°F to 60.0°C or 32.0 to 140.0°F Resolution pH: 0.01; EC: 1 μS/cm; TDS: 1 ppm; Temperature: 0.1°C or 0.1°F Accuracy Dual-level Backlit LCD! pH: 0.01; EC: 0.01 mS/cm; TDS: 0.01 ppt; Temperature: 0.1°C or 0.1°F pH: ±0.05; EC/TDS: ±2% F.S.; Temperature: ±0.5°C or ±1°F pH Calibration EC/TDS Calibration EC/TDS Conv. Factor 1 or 2 points with 2 sets of memorized buffers Automatic 1 point Adjustable from 0.45 to 1.00 Temp. Compensation pH: automatic; EC/TDS: automatic, BETA (β) is adjustable from 0.0 to 2.4%/°C Battery Type Battery Life Environment Dimensions/Weight (4) 1.5V with BEPS (Battery Error Prevention System) Approx. 100 hrs of continuous use; auto shut-off after 8 minutes of non-use 0 to 50°C (32 to 122°F); 100% RH 163 x 40 x 26 mm (6.4 x 1.6 x 1”)/85 g (3.0 oz.) ORDERING INFORMATION HI 991404 is supplied complete with HI 1293D pH electrode, fixed HI 7630 probe, pH and EC calibration solutions, 12 Vdc power adapter and instructions. HI 991405 is supplied complete with HI 1293D pH electrode, fixed HI 7630 probe, pH and EC calibration solutions, 12 Vdc power adapter and instructions. ACCESSORIES HI HI HI HI HI HI HI HI HI HI 7004M pH 4.01 calibration solution, 250 mL 7007M pH 7.01 calibration solution, 250 mL 7010M pH 10.01 calibration solution, 250 mL 70030P 12.88 mS/cm calibration solution, (25) 20 mL sachets 70031P 1413 μ/cm calibration solution, (25) 20 mL sachets 70032P 1382 ppm calibration solution, (25) 20 mL sachets 70038P 6.44 ppt calibration solution, (25) 20 mL sachets 70442P 1500 ppm calibration solution, (25) 20 mL sachets 70300M Electrode storage solution, 250 mL 7061M Probe cleaning solution, 250 mL HI 981405N pH/EC Monitor Featuring pH and EC Simultaneous Display The HI 981405N is ideal for agricultural, horticultural and hydroponics applications where pH and EC levels need to be continuously monitored for optimal plant growth. SPECIFICATIONS Range Resolution pH: 0.1; 0.01 mS.cm Accuracy pH: ±0.2; EC: ±0.2% F.S. Calibration TDS Version Available HI 981404N w/0.7 conv. fac. HI 983302N pH: 0.0 to 14.0; EC: 0.00 to 9.99 mS.cm 1 or 2 points for pH, Manual 1 point EC Temperature Compensation Probe Power Supply Input Impedance Environment Dimensions (meter only) Weight ORDERING INFORMATION ACCESSORIES HI 981405N is supplied complete with HI 1286 pH electrode, HI 7632 EC probe, HI 1283 grounding bar, pH and EC calibration solutions (20 mL each), screwdriver, 12 Vdc adapter and instructions. HI 7004M pH 4.01 calibration solution, 250 mL HI 7007M pH 7.01 calibration solution, 250 mL HI 7010M pH 10.01 calibration solution, 250 mL Automatic 5 to 50°C (EC only) HI 7632 with 2 m (6.6’) cable (included) 12 VDC adapter (included) 1012 Ohm 0 to 50°C (32 to 122°F); max. 95% RH 160 x 110 x 35 mm (6.3 x 4.3 x 1.4”) 300 g (10.6 oz) HI 70039P 5000 μS/cm calibration solution, (25) 20 mL sachets HI 70300M Electrode storage solution, 250 mL HI 7061M Electrode cleaning solution, 250 mL www.hannainst.com/usa 29 Monitoring Systems HI 981504/5 • HI 981504/7 pH/TDS/Temperature Monitor • Simultaneous display • 3 backlit LCDs • 2 models available for 0.5 or 0.7 TDS factors • Measure in °C or °F • Extra-large displays • 12 VDC power supply The HI 981504 has been designed for continuous and simultaneous monitoring of pH, TDS and temperature. Simply install the HI 981504 above the sample to be tested, plug the instrument to the mains and immerse the probes. pH, TDS and temperature measurements will be simultaneously displayed on three backlit LCDs. Users can easily select the temperature unit through a switch on the back panel. The HI 1286 gel-filled pH electrode is provided with a waterproof sheath to protect the BNC connector. The unique design of the electrode provides longer life in aggressive solutions. The HI 7634 TDS probe is easy to clean and requires little maintenance. Measurements are accurate and the meter can be calibrated at on or two points for pH and at a single point for TDS. Temperature range is factory calibrated. Two models are available: • • HI 981504/5 with 0.5 TDS factor HI 981504/7 with 0.7 TDS factor SPECIFICATIONS HI 981504 pH: 0.0 to 14.0; TDS: 0 to 1990 ppm; Temperature: -10.0 to 60.0°C or -14.0 to 140.0°F Range Resolution pH: 0.1; TDS: 10 ppm; Temperature: 0.1°C or 0.1°F Accuracy pH: ±0.2; TDS: ±2% F.S.; Temperature: ±0.3°C or ±0.5°F pH Calibration Manual 2 points through trimmers TDS Calibration Manual 1 point through trimmer TDS Factor 0.5 (HI 981504/5) or 0.7 (HI 981504/7) pH: HI 1286 (included); TDS: HI 7634 (fixed); Temperature: Stainless steel, 2 m cable (fixed) Probes Temp. Compensation Automatic, 5 to 50°C (41 to 122°F), for TDS readings only Power Supply 12 VDC power adapter (included) Environment Dimensions/Weight 0 to 50°C (32 to 122°F); 95% RH 160 x 110 x 35 mm (6.3 x 4.3 x 1.4”)/560 g (1.2 lb.) ORDERING INFORMATION HI 981504 is supplied with HI 1286 pH electrode, HI 7634 TDS probe, temperature probe, TDS sachet, (2) cleaning solution sachets, screwdriver, 12 Vdc power adapter and instructions. ACCESSORIES HI HI HI HI HI HI HI HI HI HI HI HI HI HI 30 1286 Double junction, plastic body pH electrode with 2 m (6.6’) cable and BNC connector. 7004M pH 4.01 buffer solution, 250 mL 70004P pH 4.01 buffer solution, (25) 20 mL sachets 7007M pH 7.01 buffer solution, 250 mL 70007P pH 7.01 buffer solution, (25) 20 mL sachets 7010M pH 10.01 buffer solution, 250 mL 70010P pH 10.01 buffer solution, (25) 20 mL sachets 7032M 1382 ppm calibration solution, 250 mL 70032P 1382 ppm calibration solution, (25) 20 mL sachets 70442M 1500 ppm calibration solution, 250 mL 70442P 1500 ppm calibration solution, (25) 20 mL sachets 70300M Electrode storage solution, 250 mL 7061M Probe cleaning solution, 250 mL 731326 Calibration screwdriver, 20 pcs HANNA instruments Agricultural Products Catalog ® 5th Edition With Great Products, Come Great Results.™ Monitoring Systems HI 9565 Thermo-Hygrometer with Dew Point Display and Calibration Data-Logging RH Probe • Store calibration data in probe for meter transfer • Backlit LCD • Displays temperature in °C and °F HI 9565 portable thermo-hygrometer is designed to provide excellent performance in harsh environments and poorly lit areas. The HI 70602 RH probe’s internal microchip can store calibration data. When the probe is connected to another hygrometer, the microchip transfers the stored calibration data and there is no need to recalibrate the instrument. The HI 9565 also features auto-off after 20 minutes of inactivity, temperature readings in Celcius and Fahrenheit, and on-line help to indicate anomalies and direct procedures. In addition to RH and temperature the HI 9565 will display the dew point with the press of a button. The dew point indicates, at a certain temperature, the presence of water vapor in the air. With this feature HI 9565 permits useful and rapid environmental monitoring where a controlled microclimate is necessary such as in greenhouses. SPECIFICATIONS HI 9565 RH: 20.0 to 95.0%; Temperature: 0.0 to 60.0°C (32 to 140°F); Dew Point: -20.0 to 60.0°C (-4.0 to 140.0°F) Range Resolution Accuracy (@20°C/68°F) RH Probe RH: 0.1%; Temperature: 0.1°C/0.1°F; Dew Point: 0.1°C/0.1°F RH: 3% (50 to 85% RH), ±4% (outside); Temperature: ±0.5°C/±1°F; Dew Point: ±0.5°C/±1°F HI 70602 RH combined probe with built in temperature sensor and microchip, 1 m cable (included) Battery Type/Life (1) 9V AA/approx. 250 hours of continuous use; auto-off after 20 minutes of non-use Environment 0 to 60°C (32 to 140°F); 98% max RH non-condensing Dimensions 164 x 76 x 45 mm (6.5 x 3 x 1.8'') Weight 340 g (12 oz.) ORDERING INFORMATION HI 9565 is supplied with HI 70602 RH probe, battery, instruction manual and blue protective case. ACCESSORIES HI 70602 RH probe with temperature sensor, 1 m (3.3’) HI 710009 Blue shockproof rubber boot HI 710010 Orange shockproof rubber boot HI 148 Temperature Indicator with Built-in LED Alarm Signal • Continuous ambient temperature monitoring • Visible LED alarm • User-selectable alarm set point The HI 148 is a rapid response continuous monitor thermometer which alerts the user when temperatures are becoming too high for delicate crops. The HI 148 can be mounted anywhere and is powered by 12 VDC. SPECIFICATIONS Range Resolution Accuracy Setpoint Alarm Sensor Power Supply Dimensions Weight HI 148 HI 148-01: -4.0 to 140°F; HI 148-00: -20.0 to 60.0°C HI 148-01: 0.1°F; HI 148-00: 0.1°C HI 148-01: ±0.9°F; HI 148-00: ±0.5°C HI 148-01: Selectable from 32.0 to 122.0°F; HI 148-00: Selectable from 0.0 to 50.0°C LED blinks when measured temperature is higher than the set point Incorporated, encapsulated stainless steel 12 VDC external power adapter (included) 86 x 94 x 33 mm (3.3 x 3.7 x 1.3”) 150 g (5.2 oz.) ORDERING INFORMATION HI 148-00 is supplied with 12 VDC adapter and instructions. HI 148-01 is supplied with 12 VDC adapter and instructions. www.hannainst.com/usa 31 Chemical Test Kits Chemical Test Kits HANNA instruments®’ Chemical Test Kits are economical, easy to use and practical in design. Each test kit comes with thorough instructions and everything necessary to perform quick and easy tests. HI 3895- Agricultural Multiparameter Test Kit Parameter Nitrogen Phosphorous Potassium pH Method Colorimetric Colorimetric Turbidimetric Turbidimetric Range(s) traces, low, med, high traces, low, med, high traces, low, med, high from 4 to 9 pH (1 pH increments) Chemical Method Ned Ascorbic acid Tetraphenylborate pH indicators # Tests 10 10 10 10 Method Colorimetric Colorimetric Turbidimetric Turbidimetric Range(s) traces, low, med, high traces, low, med, high traces, low, med, high from 4 to 9 pH (1 pH increments) Chemical Method Ned Ascorbic acid Tetraphenylborate pH indicators # Tests 25 25 25 25 Weight 3.7 oz. (105 g) HI 3896- Agricultural Multiparameter Test Kit Parameter Nitrogen Phosphorous Potassium pH Weight 23.3 oz. (660 g) Agricultural Single Parameter Test Kits Parameter & (Code) Method Range(s) Chemical Method # Tests Weight Acidity (HI 3820) Titration 0-100 mg/L 0-500 mg/L Methyl-orange Phenolphthalein 110 total 32 oz. (910 g) Alkalinity (HI 3811) Titration 0-100 mg/L 0-300 mg/L Phenolphthalein Bromophenol blue 110 total 16 oz. (460 g) Titration Colorimetric Titration Titration 0-500 gpg 0-2.5 mg/L 0-5.0 mg/L >0.0 meq/100g Bromophenol blue Nessler Boric Acid EDTA 100 25 100 100 (approx.) 13 oz. (363 g) 6.3 oz. (180 g) 27.5 oz. (780 g) 339 g Carbon Dioxide (HI 3818) Titration 0-10.0 mg/L 0-50.0 mg/L 0-100 mg/L Phenolphthalein 110 total 16 oz. (460 g) Chloride (HI 3815) Titration Mercuric Nitrate 110 total 16 oz. (460 g) Silver Nitrate Titration 100 total 23.4 oz. (664 g) Calcium Sulfate 100 total 31 oz. (883 g) EDTA 100 total 16 oz. (460 g) EDTA EDTA EDTA Phenanthroline EDTA Phenanthroline Cadmium reduction 50 50 50 50 50 50 100 4.2 oz. (120 g) 4.2 oz. (120 g) 4.2 oz. (120 g) Cadmium reduction 100 total 36 oz. (1026 g) Sulfanilamide 100 5.6 oz. (160 g) Modified Winkler 110 total 32 oz. (910 g) Checker Disc Checker Disc Titration 0-150 mg/L 40-500 mg/L 400-3000 mg/L Fe: 0-5 mg/L 40-500 mg/L 0-5 mg/L 0-50 mg/L IW: 0-50 mg/L Soil: 0-60 mg/L 0-1 mg/L 0-10 mg/L 0-5 mg/L 0-2.3 mg/L 4.0-10.0 pH 0-40 g/kg DPD pH indicators Mercuric nitrate 100 300 110 34 oz. (966 g) 7.5 oz. (215 g) 16 oz. (460 g) DiST 4+test kit >0.0 meq/L Titration 100 27.6 oz. (785 g) Checker Disc 0-4.0 mg/L 0-20.0 mg/L Zincon 100 22.8 oz. (647 g) Alkalinity, Total (HI 38014) Ammonia (HI 3824) Boron (HI 38074) Calcium and Magnesium (soil) (HI 38080) Chloride (HI 38015) 0-100 mg/L 0-1000 mg/L 500-10.000 mg/L 5.000-100.000 mg/L Titration Gypsum Requirement & Exchangeable Sodium (HI 38083) Titration GR: 0-213 metric ton /ha ES: 0-56.4 meq/100g soil Hardness (HI 3812) Titration 0-30 mg/L 0-300 mg/L Hardness (HI 3840) Hardness (HI 3841) Hardness (HI 3842) Iron & Total Hardness (HI 3889) Iron (HI 3834) Nitrate (HI 3874) Nitrate, Irrigation Water & Soil (HI 38050) Nitrite (HI 3873) Titration Titration Titration Colorimetric Titration Colorimetric Colorimetric Checker Disc Colorimetric Oxygen, Dissolved (HI 3810) Titration Ozone (HI 38054) pH (HI 38058) Salinity (HI 3835) Sodium Absorption Ratio (SAR) (HI 38078) Zinc, HR (HI 38076) 32 HANNA instruments Agricultural Products Catalog ® 5th Edition 9 oz. (260 g) 5 oz. (145 g) 5.4 oz. (156 g) With Great Products, Come Great Results.™ Monitoring Systems HI 141 Series Temperature Dataloggers with Internal and External Sensors • • • • IP 67 waterproof casing 1 or 2 channels 1 second to 24 hour logging interval Programmable high and low alarms The HI 141 series is a family of temperature data loggers with either one or two channels, internal or external temperature sensors, and an optional LCD. External temperature sensor models feature one or two stainless steel sensors on a 1 meter (3.3') cable for direct insertion. HI 141 can store up to 16,000 temperature samples in a protected, non-volatile EEPROM memory. The logging interval can be set from once per second, up to every 24 hours, and logging delay start can be set anywhere up to 199 hours. The MIN or MAX temperature between logging intervals can also be stored. All of your collected data is tamper-proof and stored into serial numbered lots. The user interacts with the logger, setting data acquisition parameters or downloading logged data, through an RS232 serial port on a Windows® PC. The HI 141000 Windows® compatible software supports communication between the logger and the PC through the HI 141001 infrared transmitter. The housing is waterproof and can include a convenient hanging loop (simply add an "H" to the end of the code). A long-life AA lithium battery provides power. For a typical 1 minute logging interval, your battery will last about 4 years. Note: Models with longer cable for external sensor are available upon request. SPECIFICATIONS Model* HI 141A HI 141B HI 141C HI 141D HI SERIES Display • • Sensor(s) 1 internal 1 external 1 internal 1 external 1 internal 1 external 2 external Range -40.0 to 80.0°C / -40.0 to 176.0°F -40.0 to 125.0°C / -40.0 to 257.0°F -20.0 to 70.0°C / -40.0 to 158.0°F -40.0 to 125.0°C / -40.0 to 257.0°F -40.0 to 80.0°C / -40.0 to 176.0°F -40.0 to 125.0°C / -40.0 to 257.0°F -40.0 to 125.0°C / -40.0 to 257.0°F HI 141G • 1 internal 1 external -20.0 to 70.0°C / -40.0 to 158.0°F -40.0 to 125.0°C / -40.0 to 257.0°F HI 141J • 2 external -40.0 to 125.0°C / -40.0 to 257.0°F HI 141E HI 141F SPECIFICATIONS FOR ALL MODELS ORDERING INFORMATION All HI 141 models are supplied with HI 740221 magnetic start key, battery and instructions. HI HI HI HI 141000 Windows® compatible software 141001 Infrared interface for PC connection 740221 Key for HI 141 magnetic start 740033 3.6 V AA lithium battery HI 98510 Checktemp ® Dip Precision Thermometer with Stainless Steel Weighted Probe • Hygienic, stainless steel weighted probe • 10' probe cable • CAL-CHECK feature • °C model available (HI 98509-01) 0.1°C (-40.0 to 100.0°C); 0.2°C (> 100.0°C); 0.1°F (-40.0 to 190.0°F); 0.3°F (> 190.0°F) Accuracy ±0.5°C (-40.0 to 0.0 and 70.0 to 100.0°C); ±0.4°C (0.0 to 70.0°C);±1.0°C (> 100.0°C); ±1.0°F (-40.0 to 32.0 and 158.0 to 212.0°F); ±0.8°F (32.0 to 158.0°F); ±2.0°F (> 212.0°F) Environment Diameter Height Weight ACCESSORIES HI 141 SERIES Resolution RH 100% 86.5 mm (3.4’’) 35 mm (1.4’’) 150 g (5.5 oz.) * For models with a molded eye for hanging, add an “H” to the end of the model number. SPECIFICATIONS Range Resolution Accuracy Probe Battery Type Life approx. Environment Dimensions Weight HI 98509-01 -20.0 to 100.0°C 0.1°C ±0.5°C (-20 to 50°C); ±0.9°C (outside) Stainless steel, 3 m (10’) cable 1.5V AAA 3 years of use 0 to 50°C (32 to 122°F); RH max 95% 106 x 58 x 19 mm (4.1 x 5.2 x 0.7) 80 g (2.8 oz.) ORDERING INFORMATION HI 98509-01 (Checktemp® -Dip C), °C readings, is supplied with weighted probe with 3 m (9.9’) cable, battery and instructions. HI 98510-01 (Checktemp® -Dip F), °F readings, is supplied with weighted probe with 3 m (9.9’) cable, battery and instructions. www.hannainst.com/usa 33 Thermometers HI 98810 • HI 98840 1 or 4 Channel Printing and Logging Thermometers • High accuracy and fast response time • Print out time, date and temperature readings • Log-on-demand HI 98810 and HI 98840 combine high accuracy and fast response with an extensive logging feature and an infrared computer transfer system. All stored measurements are complete with time, date sample and probe number. The logon-demand function is activated by simply pressing one button, while for automatic logging, the user can select a time interval from 1 to 180 minutes. All logged data can be transferred to a PC by placing the instrument on the HI 9200 infrared interface, connected to the computer serial port. The connection is handled with the HI 92000 Windows® compatible software from HANNA instruments®. The large backlit LCD allows readings in dimly lit conditions. These instruments can be powered with batteries or with a 12 VDC supply. HI 98810 accepts one temperature probe while HI 98840 can be connected to 4 separate probes at the same time. HI 98810 is supplied with an HI 762BL temperature probe (for general purpose/ liquid measurements). Both models use the HI 762 series of thermistor probes by HANNA instruments®. ORDERING INFORMATION HI 98810 is supplied complete with HI 762BL temperature probe with 1 m cable, 5 paper rolls, batteries, rugged carrying case and instructions. HI 98840 is supplied with 5 paper rolls, batteries, rugged carrying case and instructions. SPECIFICATIONS ACCESSORIES Resolution HI HI HI HI HI HI HI HI HI 762BL General purpose/liquid temperature probe with 1 m cable 762L/10 General purpose/liquid temperature probe with 10 m cable 762-18C Test key at -18.0°C 762000C Test key at 0.0°C 762070C Test key at 70.0°C 710034 Paper roll (10 pcs.) 710035 Ink cartridge (1 pc.) 9200/9 Serial interface for PC connection 92000 Windows® compatible software ±0.4°C (-20 to 120°C); ±0.7°C (outside); ±0.8°F (-4 to 248°F); 1.3°F (outside) (for 1 year, excluding probe error) Accuracy Channels Probe 1 HI 762BL (included) Printer low power impact, 14 characters per line, using 38 mm plain paper (HI 710034) Printing/Logging Interval selectable at 1, 2, 5, 10, 15, 30, 60, 120 or 180 minutes PC Connection (4) 1.5V AA battery or 12 VDC input/approx. 350 hours (without printing and backlight); auto-off selectable after 5, 10, 15, 30, 45 or 60 min. of non-use Range Resolution Accuracy Probe Battery Type/Life Environment Dimensions Weight Memory functions Reads both °C & °F Min, max and hold keys High accuracy HI 9043 is a hand-held thermometer that uses a K-type probe (HI 766 series) together with an advanced microprocessor to deliver temperature measurements in the higher ranges. ® HI 9043 -50.0 to 1350°C; -58.0 to 2462°F 0.1°C (-50.0 to 199.9°C); 1°C (outside); 0.1°F (-58.0 to 399.9°F); 1°F (outside) ±0.2% F.S. (for 1 year, excluding probe error) K-thermocouple type, HI 766 series (not included) (1) 9V AA/approx. 500 hours of continuous use -10 to 50°C (14 to 122°F); RH max 95% 180 x 83 x 40 mm (7.1 x 3.3 x 1.6’’) 226 g (8.0 oz.) ORDERING INFORMATION HI 9043 is supplied complete with battery, protective case and instructions. ACCESSORIES HI HI HI HI HI HI The powerful microprocessor also furnishes this meter with memory functions. Simply press a button and the meter will recall the highest and lowest temperatures measured in the cycle. A hold key will guarantee the user plenty of time to record the readings. HANNA instruments Agricultural Products Catalog 0 to 50°C (32 to 122°F); RH max 95% 220 x 82 x 66 mm (8.7 x 3.2 x 2.6’’) 550 g (1.2 lb.) SPECIFICATIONS K-Type Thermocouple Thermometer with Min, Max and HOLD 34 4 HI 762 series (not included) HI 9200 interface through RS232 serial port and using HI 92000 software (not included) Environment Dimensions Weight HI 9043 HI 98840 -50.0 to 150.0°C; -55.0 to 300.0°F 0.1°C (-30.0 to 130°C); 0.2°C (outside); 0.1°F (-18 to 225°F); 0.2°F (225 to 260°F); 0.3°F (outside) Power Supply/Life • • • • HI 98810 Range 5th Edition 766C Penetration, K-thermocouple probe with 1 m cable 766E1 General purpose, K-thermocouple probe with 1 m cable 710009 Shockproof rubber boot, blue 710010 Shockproof rubber boot, orange 710020 Spare protective case 721316 Rugged carrying case With Great Products, Come Great Results.™ Thermometers HI 9063 Waterproof and Heavy-duty K-Type Thermocouple Thermometer • • • • High accuracy and resolution Reads both °C & °F Min, max and Hold keys Large dual-level display Instrumentation used in the field or industry is subjected to environmental extremes. Due to this problem, HANNA instruments® has developed the HI 9063 to satisfy all of your heavy-duty application needs. This upgraded version of HI 9063 benefits from HANNA instruments®’ extensive experience in producing instruments that surpass your requirements. The measurement ceiling has been raised, auto-ranging added and accuracy enhanced. Because it is often necessary to know the highest and lowest temperatures measured during a certain process, HANNA instruments® has incorporated a dual-level LCD that shows the current, minimum and maximum achieved temperatures. Temperature readings are linearized for increased accuracy and resolution is automatically switched from 0.1° to 1° at 200°C (400°F) and above. SPECIFICATIONS Range Resolution Accuracy Probe Battery Type / Life Environment Dimensions Weight ORDERING INFORMATION HI 9063 / HI 9063C -50.0 to 199.9°C; 200 to 1350°C; -58.0 to 399.9°F; 400 to 2462°F 0.1°C (-50.0 to 199.9°C); 1°C (outside); 0.1°F (-58.0 to 399.9°F); 1°F (outside) ±0.2% F.S. (for 1 year, excluding probe error) K-thermocouple type, HI 766 series (4) 1.5V AA / approx. 2000 hours of continuous use -10 to 50°C (14 to 122°F); RH max 100% 196 x 80 x 60 mm (7.7 x 3.1 x 2.4’’) 500 g (1.1 lb.) Thermistor Probe and IR gy Inf S enso r red a r Te c h n SPECIFICATIONS Range Resolution Accuracy IR Response Time Optic IR Coefficient Battery Type/Life Dimensions Weight olo HI 99556-01 IR: 14 to 572°F; Thermistor Probe: -40.0 to 302°F IR: 1°F; Thermistor Probe: 1°F IR: ±2% of reading or ±3°F; Thermistor Probe: ±1°F 1 second 3:1 ratio (ratio of distance to DIA of target) 9V/approx. 300 hours of continuous use 143 x 80 x 38 mm (5.6 x 3.1 x 1.5”) 320 g (11.3 oz.) HI 9063 is supplied complete with batteries, protective case and instructions. HI 9063C is supplied complete with HI 766HD probe handle, HI 766PE1, HI 766PB, HI 766PD probes, batteries, rugged carrying case and instructions. ACCESSORIES HI HI HI HI 766C Penetration, K-thermocouple probe with 1 m cable 766E1 General purpose, K-thermocouple probe with 1 m cable 710021 Spare protective case 721317 Rugged carrying case HI 99556-01 Infrared/Penetration Thermometer • Ideal for spot checking & complete verification of temperatures • Fast response time • Rugged housing • Models available in °C The new dual purpose HI 99556-01 is ideal for checking temperatures everywhere from the greenhouse to the field. Spot check with the infrared probe and get a closer look with the thermistor thermometer. Comes complete with probe and wrist strap. ORDERING INFORMATION HI 99556-01 is supplied with HI HI 765PW stainless steel probe, batteries and instructions. ACCESSORIES HI HI HI HI HI 710004 Soft carrying case 721316 Hard carrying case 710007 Blue shockproof rubber boot 731318 Sensor wipe tissues 765PW Temperature probe for HI 99556-01 www.hannainst.com/usa 35 Thermometers HI 935005 • HI 935005N K-Type Thermocouple Thermometers Waterproof, Featuring Min, Max & HOLD • • • • Measures in °C or °F 1600 Hours of Battery Life High Range with Auto-ranging Auto-calibration and backlit LCD (HI 935005N only) HI 935005 is a hand-held waterproof thermometer that uses a K-type sensor together with an advanced microprocessor to deliver accurate temperature measurement with an extraordinary 1600 hour battery life. The dual-level LCD displays current temperature along with the minimum and maximum extremes achieved during the session. Battery level indication with low battery warning and error prevention furnishes this meter with advanced battery management functions. A HOLD button allows the user to record readings. The °C/°F button instantly switches between the Celsius and Fahrenheit ranges. For even greater accuracy or dimly lit areas, select the HI 935005N. For even greater accuracy, a CAL button allows the operator to remove the combined meter and probe interchange error in an ice bath at 0°C. In addition to the calibration feature, HI 935005N features a user-activated backlight for low or no light conditions. The HANNA instruments® exclusive shockproof rubber boots, HI 710007 and HI 710008, offer maximum impact protection. A wide variety of interchangeable probes are available to meet specific applications. ORDERING INFORMATION HI 935005 is supplied complete with batteries, protective case and instructions. HI 935005N is supplied complete with batteries, protective case and instructions. ACCESSORIES HI HI HI HI HI HI 766C Penetration K-type temperature probe with 1 m cable 766D Air K-type temperature probe with 1 m cable 766E1 General purpose K-type temperature probe with 1 m cable 710007 Shockproof rubber boot, blue 710008 Shockproof rubber boot, orange 710018 Spare protective case SPECIFICATIONS Range HI 935005/HI 935005N -50.0 to 199.9°C and 200 to 1350°C; -58.0 to 399.9°F and 400 to 2462°F 0.1°C (-50.0 to 199.9°C) and 1°C (outside); 0.1°F (-58.0 to 399.9°F) and 1°F (outside) ±0.2% F.S. (for 1 year, excluding probe error) K-thermocouple type, HI 766 series (not included). See opposite page bottom Resolution Accuracy Probe Battery Type / Life (3) 1.5V AA / approx. 1600 hours of continuous use (with backlight off); HI 935005 only: auto-off selectable after 8 or 60 minutes of non-use (can be disabled) Environment Dimensions Weight -10 to 50°C (14 to 122°F); RH max 100% 150 x 80 x 36 mm (5.9 x 3.1 x 1.4’’) 235 g (8.3 oz.) HI 935007 Direct K-Type Probe Thermometer with Waterproof Casing The HI 935007 enhances the range of portable HANNA thermometers by measuring temperature as high as 1350°C and 2462°F. The HI 935007 is offered at such an attractive price bracket to make it possible for every operator to carry his or her own professional instrument. The fixed HI 766C penetration probe with 1 meter (3.3’) of cable is also supplied. Three common AA batteries provide up to 1600 hours of continuous operation. All these features with a wide measurement range and low cost make this meter extremely popular in catering, food preparation, and restaurants. SPECIFICATIONS Range Resolution Accuracy Probe Battery Type / Life Environment Dimensions Weight 36 HI 935007 -50.0 to 199.9°C; 200 to 1350°C or 58.0 to 399.9°F; 400 to 2462°F 0.1°C; 1°C; 0.2°F; 1°F ±0.2% F.S. (for 1 year, excluding probe error) HI 766C (fixed) (3) 1.5V AA / approx. 1600 hours of use; auto-off selectable after 8 or 60 minutes of inactivity (can be disabled) -10 to 50°C (14 to 122°F); RH max 100% 150 x 80 x 36 mm (5.9 x 3.1 x 1.4’’) 235 g (8.3 oz.) HANNA instruments Agricultural Products Catalog ® 5th Edition ORDERING INFORMATION HI 935007 is supplied complete with fixed probe HI 766C with 1 m cable, batteries and instructions ACCESSORIES HI HI HI HI 710004 Soft carrying case 710031 Rugged carrying case 710007 Shockproof rubber boot, blue 710008 Shockproof rubber boot, orange With Great Products, Come Great Results.™ Thermometers HI 98801 • HI 98804 K, J, T-Type Thermocouple Logging Thermometers with GLP • • • • • Measures in °C or °F Dual-level backlit LCD Selectable printing and logging intervals Computer compatibility Factory calibration certificate available HI 98801 and HI 98804 thermometers combine the high accuracy and fast response time of the printing series with an extensive logging feature and infrared computer transfer system. These meters support K, J or T-thermocouple probes, one for HI 98801 and up to 4 for HI 98804. All stored data are always complete with date, time, sample and probe number. Measurements can be stored automatically at defined intervals (user selectable from 1 to 180 minutes), or the current reading can be printed or logged-on-demand by just pressing a button. The backlit LCD allows operations even in poorly lit areas. Computer connection is through the HI 9200 infrared interface and serial port. Just place the meter on the interface and the HI 92000 application software will transfer all logged data. Both models can be powered with batteries or 12 Vdc input. HANNA instruments® produces a wide range of K-type thermocouple probes that can be used with this thermometer for many applications (HI 766 series). SPECIFICATIONS HI 98801 is supplied with 5 paper rolls, batteries, rugged carrying case and instructions. HI 98804 is supplied with 5 paper rolls, batteries, rugged carrying case and instructions. ACCESSORIES HI HI HI HI HI HI HI HI HI 766C Penetration, K-type temperature probe with 1 m cable 766E1 General purpose, K-type temperature probe with 1 m cable 710005 115 Vac/12 Vdc power adapter 710006 230 Vac/12 Vdc power adapter 710034 Paper roll (10 pcs.) 710035 Ink cartridge (1 pc.) 9200/9 Serial interface for PC connection 92000 Windows® compatible software 721317 Rugged carrying case HI 98801 • HI 98804 K: -200.0 to 999.9°C; 1000 to 1370°C; -300.0 to 999.9°F; 1000 to 2500°F; J: -200.0 to 760.0°C; -300.0 to 999.9°F; 1000 to 1400°F; T: -200.0 to 400.0°C; -300.0 to 750.0°F; Range Resolution ORDERING INFORMATION K: 0.1°C (-99.9 to 999.9°C); 1°C (1000 to 1370°C); 0.2°C (-200.0 to -100.0°C); 0.2°F (-199.9 to 999.9°F); 1°F (1000 to 2500°F); 0.3°F (-300.0 to -200.0°F); J: 0.1°C (-149.9 to 760.0°C); 0.2°C (-200.0 to -150.0°C); 0.1°F (32.0 to 999.9°F); 1°F (1000 to 1400°F); 0.2°F (-300.0 to 32.0°F); T: 0.1°C (-99.9 to 400.0°C); 0.2°C (-200.0 to -100.0°C); 0.1°F (300.0 to 750.0°F); 0.2°F (-149.9 to 300.0°F); 0.3°F (-300.0 to -150.0°F) Accuracy Channels Probe Cold Junction Printer Printing/Logging Interval PC Connection ±0.5°C (-200.0 to 999.9°C); ±1°C (outside); ±1°F (for 1 year, excluding probe error) 1 (HI 98801), 4 (HI 98804) K, J, T-type thermocouple (not included) NTC 10 K; 0.1°C resolution; ±0.3°C accuracy Low power impact, 14 characters per line, using 38 mm plain paper (HI 710034) Selectable at 1, 2, 5, 10, 15, 30, 60, 120 or 180 minutes HI 9200 interface through RS232 serial port and using HI 92000 software (not included) Power Supply (4) 1.5V AA battery / approx. 350 hours (without printing and backlight); auto-off selectable after 5, 10, 15, 30, 45 or 60 minutes of non-use; 12 Vdc input Environment Dimensions Weight 0 to 50°C (32 to 122°F); RH max 95% 220 x 82 x 66 mm (8.7 x 3.2 x 2.6’’) 550 g (1.2 lb.) HI 766TR1 HI 766TR2 Penetration Probe Penetration Probe • • • • • • • • • • Use: semi-solids, liquids MAX temperature: 250°C/482°F Response time (90% of final value): 10 sec. Probe length: 500 mm (19.7”); DIA 10 mm (0.4”) Tube in stainless steel Use: semi-solids, liquids MAX temperature: 250°C/482°F Response time (90% of final value): 10 sec. Probe length: 1000 mm (39.3”); DIA 10 mm (0.4”) Tube in stainless steel www.hannainst.com/usa 37 NEMA Boxes Make Your Own Control & Injection Systems HI 1211 • HI 1222 Controller & Monitors in an Industrial Enclosure Choose from TDS, Conductivity, pH, Resistivity or ORP. These controllers will allow any system to be cost effectively monitored 24 hours a day. • • • • • • • • NEMA protection LCD display Alarm contact Key pad touch setting Calibration and adjustable set points Multi-ranges for TDS and conductivity Available in 115 V or 12 VDC Simple to Install - just plug in probe, power & relay meter and you’re in business! HI 1222 with dual meter capability Combine any of HANNA’s Mini Controllers into the HI 1222 for versatile monitoring and control. HI 1211 with single meter capability 38 HANNA instruments Agricultural Products Catalog ® 5th Edition Choose from the single capability HI 1211 or the dual capability HI 1222 With Great Products, Come Great Results.™ Panels Custom Configured to Your Specific Agricultural Needs! • Knowledgeable support • Pre-wired and ready to be installed • Built by the manufacturer to YOUR specs! At HANNA, we want to make your life easier! Buying process instrumentation is easy, but setting it up to do its task and interact with other devices is another thing. It can require engineers, electricians, instrumentation specialists and plumbers. Most large size companies have the resources in-house to build control panels and install them, but this may not be your case. Big or small, we’re here to help! As a manufacturer, we understand that it may be difficult and expensive for a small or mid-size company to seek or subcontract people qualified in this field. This is the reason we added the control panel design department. At HANNA, we know what our products can do for you and we are committed to help you integrate our products to your applications. Whether your needs are for a 6 x 6’ complete control system with 10 state of the art controllers or a low cost mini-controller in a 6 x 6” box, we will build it. HANNA ensures that no one is left on their own when it comes to customized control panels! We’ll work with you! Simply call us and tell us about your present or future applications. Our design department together with your HANNA authorized dealer will work with you to fill your needs, solve your problems and engineer turnkey solutions to the most complex problems. All systems are custom designed to your specifications, pre-wired and ready to be installed. Just plug them in! The best value on the market! Who knows product better than the manufacturer? This is why we go the extra mile for our customers. Our buying power lowers overall costs of our custom control panels to the benefit of our customers. Your local HANNA authorized dealer works with us to offer outstanding prices, knowledgeable customer service and fast delivery times. Service contracts are also available for maintenance and calibration. www.hannainst.com/usa 39 Customized Panels HANNA Customized Panels mini Controllers BL Series Mini Controllers The Perfect Solution for Water Analysis and Control • • • • • • • Any system can be cost effectively monitored 24 hours a day. Fire retardant casing Larger LCD Selectable overdose protection system External disable feature Selectable control override Matching pin connection 4-20 mA analog output Traditionally, process monitoring and control has required considerable investment in system design, equipment, maintenance and training. With the introduction of the BL Series Mini-Controllers, HANNA provides a solution for industries that require reliable, efficient and affordable process monitoring and control. The new BL Series Mini-Controllers are easy to use, durable and provide precise monitoring and control of pH, ORP, TDS, EC, and Resistivity. Each Mini-Controller is 8 x 5 cm (3 x 2") in size and weighs less than 9 oz. The compact size and simplicity of design allows for easy installation and integration into almost any existing system. Fit these controllers into our popular custom built NEMA boxes! page 38 BL 981411-0 • BL 981411-1 BL 931700-0 • BL 931700-1 BL 982411-0 • BL 982411-1 BL 932700-0 • BL 932700-1 0.0 to 14.0 pH 0.00 to 14.00 pH 0 to 1000 mV ±1000 mV 0.1 pH 0.01 pH 1 mV 1 mV ±0.2 pH ±0.02 pH ±5 mV ±5 mV ±0.1 pH ±0.10 pH/±0.10 mA ±5 mV Range Resolution Accuracy (@20°C/68°F) Typical EMC Deviation Calibration The control action of each Mini-Controller can be disabled, set to automatic or manually operated directly from the front panel. A selectable "Overtime" overdosing system can deactivate a valve, pump, or other connected device if activation continues for more than the set time, which is adjustable from 5 up to 30 minutes. pH & ORP SPECIFICATIONS Each model is a single set point controller designed to control the operation of a pump, valve or mechanical device for dosing, filling and emptying tanks and rerouting flow. ±5 mV / ±0.10 mA Manual, through CAL (offset) trimmer Manual, through offset & slope trimmers Manual, through CAL trimmer Dosing Contact Maximum 2A (fuse protected), 250 VAC, 30 VDC Maximum 2A (fuse protected), 250 VAC, 30 VDC Dosing Selection Acid or Alk, selectable on the back panel Rdx or Oxd, selectable on the back panel =Acid dosage=Relay ON if Measure > Setpoint =Reductant dosage=Relay ON if Measure > Setpoint Contact Open Contact Close Setpoint =Alk dosage=Relay ON if Measure < Setpoint =Oxidant dosage=Relay ON if Measure < Setpoint Adjustable, from 0 to 14 pH - Adjustable, from 0 to 1000 mV Adjustable, from -1000 to 1000 mV - 4 to 20 mA, accuracy ±0.20 mA, 500 W maximum load - 4 to 20 mA, accuracy ±0.20 mA,500 W maximum load Recorder Output CONDUCTIVITY SPECIFICATIONS Range Resolution Accuracy (@20°C/68°F) Typical EMC Deviation Probe Temperature Compensation Calibration BL 983313-0 • BL 983313-1 Maximum 2A (fuse protected), 250 VAC, 30 VDC; Contact close when measure > Setpoint Dosing Contact Setpoint 40 BL 983327-0 • BL 983327-1 BL 983320-0 • BL 983320-1 BL 983322-0 • BL 983322-1 0 to 1999 μS/cm 0.00 to 10.00 mS/cm 0.0 to 199.9 μS/cm 0.00 to 19.99 μS/cm 1 μS/cm 0.01 mS/cm 0.1 μS/cm 0.01 μS/cm ±2% f.s. ±2% f.s. ±2% f.s. ±2% f.s. ±2% f.s. ±2% f.s. ±2% f.s. ±2% f.s. HI 7634-00 EC/TDS probe (optional) HI 7632-00 EC/TDS probe (optional) HI 7634-00 EC/TDS probe (optional) HI 7634-00 EC/TDS probe (optional) Automatic from 5 to 50°C (41 to 122°F); β=2%/°C Automatic from 5 to 50°C (41 to 122°F); β=2%/°C Manual, through CAL trimmer Manual, through CAL trimmer Adjustable, from 0 to 1999 μS/cm Adjustable, from 0 to 10 mS/cm HANNA instruments Agricultural Products Catalog ® 5th Edition Maximum 2A (fuse protected), 250 VAC, 30 VDC; Contact close when measure > Setpoint Adjustable, from 0 to 199.9 μS/cm Adjustable, from 0 to 19.99 μS/cm With Great Products, Come Great Results.™ • 2 amp built-in fuse • Removable modules for easy maintenance • Quick-connect terminal blocks CONDUCTIVITY & TDS SPECIFICATIONS All Models Overtime Power Consumption Installation Category Power supply: BL XXXXXX-0 BL XXXXXX-1 Dimensions Adjustable, typically from 5 to approx. 30 min. 10 VA II External (fuse protected) 12 VDC 115/230 VAC (fuse protected); 50/60 Hz 79 x 49 x 95 mm (3.1 x 1.9 x 3.7”) SPECIFICATIONS BL 983317-0 and BL 983317-1 BL 983319-0 • BL 983319-1 Range Resolution Accuracy (@20°C/68°F) Typical EMC Deviation TDS Conversion Factor Probe Temperature Compensation Calibration 0.00 to 10.00 mS/cm 0 to 1999 ppm 0.00 to 10.00 ppt 0 to 999 ppm 0.01 mS/cm 1 ppm 0.01 ppt 1 ppm ±2% f.s. ±2% f.s. ±2% f.s. ±2% f.s. ±2% f.s. ±2% f.s. ±2% f.s. ±2% f.s. 0.65 0.5 0.5 HI 7632-00 EC/TDS probe (optional) HI 7634-00 EC/TDS probe (optional) HI 7632-00 EC/TDS probe (optional) HI 7634-00 EC/TDS probe (optional) Automatic from 5 to 50°C (41 to 122°F); β=2%/°C Automatic from 5 to 50°C (41 to 122°F); β=2%/°C Manual, through CAL trimmer Manual, through CAL trimmer Dosing Contact Setpoint BL 983318-0 • BL 983318-1 Maximum 2A (fuse protected), 250 VAC, 30 VDC Contact close when measure < Setpoint Adjustable, from 0 to 10 mS/cm BL 983329-0 • BL 983329-1 Maximum 2A (fuse protected), 250 VAC, 30 VDC Contact close when measure > Setpoint Adjustable, from 0 to 1999 ppm Adjustable, from 0 to 10 ppt Adjustable, from 0 to 999 ppm BL 983315-0 • BL 983315-1 BL 983321-0 • BL 983321-1 BL 983324-0 • BL 983324-1 BL 983314-0 • BL 983314-1 0.0 to 199.9 ppm 0.1 ppm ±2% f.s. ±2% f.s. 0.5 0.00 to 19.99 ppm 0.01 ppm ±2% f.s. ±2% f.s. 0.5 HI 7634-00 EC/TDS probe (optional) 0.0 to 49.9 ppm 0.1 ppm ±2% f.s. ±2% f.s. 0.5 0.00 to 19.90 MW/cm 0.10 MW/cm ±2% f.s. ±2% f.s. HI 3314 resistivity probe (included) TDS & RESISTIVITY SPECIFICATIONS Range Resolution Accuracy (@20°C/68°F) Typical EMC Deviation TDS Conversion Factor Probe Temperature Compensation Automatic from 5 to 50°C (41 to 122°F); β=2%/°C Automatic and linear from 5 to 50°C (41 to 122°F) - β=2.5, 3.5 and 4.5%/°C, user-selectable Temperature Coefficient Calibration Dosing Contact Setpoint Manual, through CAL trimmer Factory Calibrated Maximum 2A (fuse protected), 250 VAC, 30 VDC; Contact close when measure > Setpoint Maximum 2A (fuse protected), 250 VAC, 30 VDC; Contact closed when measure < setpoint Adjustable, from 0 to 199.9 ppm Adjustable, from 0 to 19.99 ppm Adjustable, from 0 to 49.9 ppm Adjustable, from 0 to 19.90 MW/cm www.hannainst.com/usa 41 mini Controllers 32 Models To Measure pH, ORP, Conductivity, TDS and Resistivity. Panel Mount Controllers HI 504 pH/ORP Controller with TeleControl™ and Sensor Check™ Digital Transmitter Input Many industrial applications require distances from the regulation system to the probe greater than the 15 meters provided by industrial probes. For these situations, the use of a transmitter is necessary. All HI 504 models are supplied with a digital transmitter input. Compared to a traditional analog transmitter, which has a maximum transmission length of 300 meters, our new digital transmitter, HI 504910 permits the connection with the controller at distances up to 1.2 km. The data transmitted can be pH, mV and temperature. This digital transmitter is compatible with the Sensor Check™ function and therefore guarantees excellent precision with continuous probe inspection. GSM Cellular Module The optimization of an industrial process plant means the reduction of costly unscheduled shutdown time. With this in mind, HANNA instruments® has developed the HI 504900 GSM cellular module* (optional). The HI 504900 is used for sending SMS alarm messages* and also requests live updates on actual process conditions from authorized personnel. The GMS cellular module can memorize one or two mobile phone numbers, where alarm messages can be sent whenever a malfunction is revealed. The SMS message immediately reports the nature of the alarm. Some causes include: Damaged pH probe, Damaged temperature probe or High setpoint exceeded. • • • • • • • • • • Sensor check™ pH/ORP electrode diagnostic system RS 485 interface Digital transmitter input Programmable auto-cleaning cycle Fail safe alarm system Automatic temperature compensation Programmable hold system Logging of the last 100 events Analog Output: data logging or PID dosage control UL certification HI 504 introduces an innovation in the concept of pH and ORP control, that enhances the entire line of process controllers engineered by HANNA instruments®. Over 25 years of experience in the production of industrial controllers have enabled us to develop this series of high performance instruments with our new telecontrol technology. This technology supplies the means to control, from whatever distance and in real time, one or more installations, allowing the user to optimize operations such as maintenance cycles. With two-way communication supplied by the RS485 output and Windows® compatible software, users can control the complete regulation process from the PC or through SMS via cellular phone. Measurement reliability is guaranteed by many self-diagnostic and troubleshooting functions, such as our innovative Sensor Check™ feature which is the result of advanced research and application know-how. The universal BNC connector allows the use of any type of industrial probe chosen for a specific application, but at the same time renders probe replacement a simple and time saving operation. The HI 504 family offers a wide range of models, designed to fit your individual needs, and is able to satisfy whatever application of monitoring and regulation you require. * Compatible phones, plans & SIM cards must be purchased separately from an outside provider and is not in any way covered by HANNA instruments® 42 HANNA instruments Agricultural Products Catalog ® 5th Edition Receive electrode status & diagnostic messages on the LCD display or via your mobile phone! * Sensor CheckTM pH/ORP As part of the powerful self-diagnostic functions of this instrument series, the Sensor Check™ system provides continuous inspection of probe status. The test is not limited to a simple signal that indicates an error in progress, but it reports the nature of the breakdown with a specific error code. With the use of the HI 504900 GSM module, errors or alarms can be sent directly to the operator's mobile phone as an SMS message. Broken electrode Dirty electrode Electrode not immersed Here are the types of breakdowns shown by sensor check: > pH electrode broken > Reference electrode dirty > Reference electrode or matching pin not immersed > Electrode junction dirty or clogged > Short-circuit between cables of pH and reference electrodes > Signal problems from the cable or connector due to humid or dirty environments The internal circuit of the instrument executes two independent tests, one for the probe and one for the reference chamber, measuring the respective impedance values every 30 seconds. These tests last for a very short period to avoid electrolysis and polarization, which can be caused by a prolonged exposure to an electric current. SPECIFICATIONS Range Resolution Accuracy (@20°C/68°F) Input Impedance Digital Output Analog Output Dosing and Alarm Relay Temperature Compensation Temperature Probe Power Supply Environment Casing Dimensions / Weight HI 504 -2.00 to 16.00 pH; -2000 to 2000 mV; -30 to 130.0°C 0.01 pH; 1 mV; 0.1°C (above -10 °C); 1°C (below -10°C) ±0.02 pH; ±2 mV; ±0.5°C (-9.9 to 130.0°C); ±1°C (-30 to -10°C) 1012 Ohm Isolated output; contact closed upon Hold mode 1 or 2 independent outputs (configuring as 0-20 mA or 4-20 mA) Electromechanical relay SPDT contact output ; 5A - 250 Vac, 5A - 30 Vdc (resistive load); fuse protected: 5A, 250V “Quick Blow” fuse Automatic or manual, -30 to 130°C Pt100/Pt1000 sensor (with automatic recognition and damage test) 24 VDC/AC; 115 Vac ±10%, 230 Vac ±10%, 100 Vac ±10%; 50/60 Hz 0 to 50°C (32 to 122°F); RH max 85% non-condensing IP54 (front panel) Panel cutout:140 x 140 mm, instrument: 144 x 144 x 170 mm / 1.6 kg (3.5 lb.) 1, single setpoint X=1 2, dual setpoint X=2 8, single setpoint & advanced cleaning X=8 9, dual setpoint & advanced cleaning X=9 ORDERING INFORMATION: Each HI 504 model is supplied complete with mounting brackets and instruction manual. Match the last letters in the product code to the corresponding numbers according to desired configuration. Direct Wire Connection or TeleControl through an RS485 Port The RS485 output is a versatile interface that can be used for connecting the HI 504 controller to many other devices. The simplest configuration is a direct wire connection to a PC (with distances up to 1.2 km), or it is possible to use either a traditional or GSM modem. The remote control can be managed with the HI 92500 Windows® compatible software. Once connected, the user can interact with the system, view parameters in real time, download process data relative to the last 100 events that have occurred and, if necessary, modify or reconfigure program settings (setpoints, alarms, cleaning cycles, stand-by times, etc.). When a connection is kept active, it is possible to continuously download and automatically store the process data in Excel® format. This data, once saved, can be easily organized into tables and graphs, used for creating records and supervising process progression. RS485 Network The RS485 output allows users to create a network composed up to 32 instruments using a simple double-wire cable. The communication speed (up to 19200 bps) allows the user to establish an RS485 network covering an area of up to 1.2 km between the two instruments at both extremities of the network. The network can be created with HI 504 units or any other HANNA instruments®. industrial controllers with RS485 output (pH 502, mV 602, etc.). The entire network can be managed by our HI 92500 software, using a simple wire connection to a PC, with the HI 504902 traditional modem or a GSM module (HI 504900 or HI 504901). 1, ON/OFF control Y=1 2, ON/OFF & PID control Y=2 2, single analog output Z=2 4, dual analog output Z=4 0, 24 VDC/AC power supply a=0 1, 115VAC power supply a=1 2, 230VAC power supply a=2 3, 100VAC power supply a=3 HI 504XYZ-a ACCESSORIES: HI HI HI HI HI HI 504900 GSM module* 504901 GSM supervisor 504902 RS485 modem (PSTN) 504910 Digital transmitter 92500 Windows® compatible software 7610 Stainless steel temperature probe with Pt100 sensor and 5 m cable HI 7611 Stainless steel temperature probe with Pt1000 sensor and 5 m cable HI HI HI HI HI HI HI HI 7004/1L pH 4.01 buffer solution, 1 L 7006/1L pH 6.86 buffer solution, 1 L 7007/1L pH 7.01 buffer solution, 1 L 7009/1L pH 9.18 buffer solution, 1 L 7010/1L pH 10.01 buffer solution, 1 L 7020L 200-275 mV test solution, 500 mL 7091L Reducing solution, 500 mL 7092L Oxidizing solution, 500 mL * Compatible phones, plans & SIM cards must be purchased separately from an outside provider and is not in any way covered by HANNA instruments® www.hannainst.com/usa 43 Panel Mount Controllers With Great Products, Come Great Results.™ Panel Mount Controllers HI 700 • HI 710 Microprocessor Conductivity and TDS Controllers with 4-ring Potentiometric Probe The HI 700 series of regulators offer state-of-the-art specifications for your process control. They can be configured for ON/OFF, Proportional, PI or PID control. Thanks to our exclusive technology, they can be customized to best fit your application. A menu-driven display aids the user throughout the operations with running messages and clear prompts. All relevant parameters can be simply adjusted and will remain memorized until overwritten. Bright LED lights show the current status even from a distance. With self-diagnostic features and extractable terminals, installation and maintenance are rapid and simple. Password protection guarantees that the calibration and predetermined parameters cannot be altered unnecessarily. The controllers can operate with 4-ring probe or 4-20 mA signal. They accept probes with or without a built-in Pt100 temperature sensor. HI 710 monitors and controls both conductivity and TDS. • • • • • • • Accurate, reliable and simple to install Extensive range for both conductivity and TDS Programmable through menu-driven display Selectable isolated output in mAs and volts On/Off, proportional, PI and PID controls Automatic or manual temperature compensation Parameters adjustable for custom applications SPECIFICATIONS • • • • • • Two Set points and one alarm relay Calibration with backup memory Password protection against tampering Fail-safe protection against power failure Status LED on front panel Self-diagnostics and troubleshooting guides HI 700 HI 710 EC: 0.0 to 199.9 μS/cm; 0 to 1999 μS/cm; 0.00 to 19.99 mS/cm; 0.0 to 199.9 EC: 0.0 to 199.9 μS/cm; 0 to 1999 μS/cm; 0.00 to 19.99 mS/cm; mS/cm; TDS: 0.0 to 100.0 ppm; 0 to 1000 ppm; 0.00 to 10.00 ppt; 0.0 to 0.0 to 199.9 mS/cm; Temperature: -10.0 to 100.0°C 100.0 ppt; Temperature: -10.0 to 100.0°C Range Resolution EC: 0.1 μS; 1 μS; 0.01 mS; 0.1 mS; TDS: 0.1 ppm; 1 ppm; 0.01 ppt; 0.1 ppt Temperature: 0.1 °C; EC: 0.1 μS; 1 μS; 0.01 mS; 0.1 mS; Temperature: 0.1 °C Accuracy (@20°C/68°F) ±0.5% F.S. (EC / TDS); ±0.5°C (0 to 70°C); ±1°C (outside) EC Calibration Automatic or manual at 1 point Temperature Compensation Automatic (with Pt100 probe) or manual from -10 to 100°C with ß = 0.00 to 10.00%/°C TDS Conversion Factor — Outputs Adjustable from 0.00 to 1.00 Analog: isolated 0-1 mA, 0-20 mA and 4-20 mA; 0-5 Vdc, 1-5 Vdc and 0-10 Vdc or digital: RS485 bi-directional opto-isolated Analog Input 4-20 mA Setpoint Relay 2 contact outputs SPDT 5A-250 Vac, 5A-30 Vdc (resistive load) Alarm Relay Contact output SPDT 5A-250 Vac, 5A-30 Vdc (resistive load) Power Supply 115 Vac ±10% or 230 Vac ±10%; 50/60 Hz Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing Dimensions Panel cutout:140 x 140 mm, instrument: 144 x 144 x 170 mm Weight 1.6 kg (3.5 lb.) ORDERING INFORMATION: ACCESSORIES 0, EC Controller 1, EC/TDS Controller HI 700 and HI 710 is supplied complete with mounting brackets and instruction manual. Match the last letters in the product code to the corresponding numbers according to desired configuration. 1, analog output 2, RS485 output HI 7 022 - 44 HI HI HI HI HI 1, 115 VAC power supply 2, 230 VAC power supply HANNA instruments Agricultural Products Catalog ® 5th Edition 504901 GSM supervisor 7030L 12880 μS/cm calibration solution, 500 mL 7031L 1413 μS/cm calibration solution, 500 mL 7033L 84 μS/cm calibration solution, 500 mL 7034L 80000 μ/cm calibration solution, 500 mL Wall Mount Controllers With Great Products, Come Great Results.™ HI 21 Advanced pH Controller with Matching Pin The HI 21 controllers are simple-to-operate, microprocessor-based process meters packed with features. For more flexibility and better resolution for chart recorders, any two points between 0 and 14 pH can be chosen to correspond to the analog output spans. Push button password programming prevents tampering. The microprocessor memory is fully programmable and has a 3 month backup power supply. The Fail Safe Alarm system protects the HI 21 against the pitfalls of process control, like power interruption or line failure. With HI 21 quick 1, 2 or 3 point calibration at pH 4.01, 7.01 and 10.01 comes standard. The temperature can be manually or automatically compensated for. You can also choose from ON/OFF, Proportional and PID control to save on chemicals. ORDERING INFORMATION: Each HI 21 model is supplied with instruction manual. 1, single setpoint X=1 2, dual setpoint X=2 5, single setpoint & advanced cleaning X=5 1, ON/OFF control Y=1 2, ON/OFF & PID control Y=2 SPECIFICATIONS Range Resolution Accuracy (@20°C/68°F) Input Impedance pH Calibration Temperature Compensation Outputs Setpoint Relay Alarm Relay 1, single analog output Z=1 2, dual analog output Z=2 3, dual analog output Z=3 HI 21XYZ-a 1, 115 VAC power supply a=1 2, 230 VAC power supply a=2 Power Supply Power Consumption Environment Protection Dimensions Weight HI 21 0.00 to 14.00 pH; -9.9 to 120°C 0.01 pH; 0.1°C ±0.02 pH; ±0.5°C 1012 Ohm Automatic, 1, 2 or 3 point, at pH 4.01, 7.01, 10.01 Automatic (with Pt100 probe) or manual from -9.9 to 120°C Digital: RS485 bi-directional opto-isolated; or analog, galvanically isolated: 0-1 mA, 0-20 mA and 4-20 mA, 0-5 Vdc, 1-5 Vdc and 0-10 Vdc 1 or 2 contact outputs SPDT 5A-250 Vac, 5A-30 Vdc (resistive load); fuse: 5A, 250V Contact output SPDT 5A-250 Vac, 5A-30 Vdc (resistive load); fuse: 5A, 250V 115 Vac ±10% or 230 Vac ±10%; 50/60 Hz; fuse: 400 mA, 250 V 15 VA 0 to 50°C (32 to 122°F); RH max. 85% non-condensing IP 54 221 x 181 x 86 mm (8.7 x 7.1 x 3.4’’) 1.4 kg (3.1 lb.) BL 7916 pH Controller and Pump • • • • pH controller and dosing pump in one compact unit. ±0.01 pH accuracy with unbeatable performance. Isolated 4 to 20 mA recorder output. Proportional dosing slows the pump down when the measured pH level approaches the set value which ensures precise dosage and avoids costly waste of chemicals due to overdosage. • Alarm contact is activated whenever the pH value varies by more than 2 pH units from the set point. • Auxiliary contacts allow the user to attach a mixer or priming pump that is activated only when the pump is dosing. • PVDF, FPM/FKM and PTFE materials are used for parts that come into contact with liquid. ORDERING INFORMATION: 220/240V ±15%; 50/60Hz version available (BL 7916D) BL 7916U is supplied with discharge and suction valves, polyethylene tubing, 110/115V power cable and instructions. ACCESSORIES: HI HI HI HI HI HI HI HI HI 721101 Pumphead, O-ring and screws 721102 Discharge valve assembly 721103 Suction valve assembly 721004 Injection valve assembly (required) 721005 Foot valve assembly (required) 721008 Ceramic weight (4) 7004L pH 4.01 buffer solution, 500 mL 7007L pH 7.01 buffer solution, 500 mL 7010L pH 10.01 buffer solution, 500 mL SPECIFICATIONS Range Resolution Accuracy (@20°C/68°F) Flow Rate Input Impedance Dosage Calibration Offset: Recorder Output Dosing Contact Alarm Contact Power Supply Environment Dimensions Weight BL 7916 0.00 to 14.00 pH 0.01 pH ±0.01 pH See table on page 43 1012 Ohm proportional, acid or base, user selectable ±1 pH with trimmer; slope: 85 to 115% with trimmer 4-20 mA (isolated) 1 isolated contact, 2A, Max. 240V, resistive load, 1,000,000 strokes 1 isolated contact, 2A, Max. 240V, resistive load, 1,000,000 strokes 110/115V ±15%; 50/60Hz (40W) 0 to 50°C (32 to 122°F); RH max 95% non-condensing 181 x 221 x 142 mm (7.1 x 8.7 x 5.6’’) 5 kg (11 lb.) www.hannainst.com/usa 45 Wall Mount Controllers HI 22 Advanced ORP Controller with Matching Pin The HI 22 controllers have been engineered with the same outstanding features as the HI 21 meters. The microprocessor memory is fully programmable and has a 3-month backup power supply. The Fail Safe Alarm system protects these meters against the pitfalls of process control. User-selectable timing capability safeguards against overdosing and saves money while protecting the environment. These instruments have a differential input, extending electrode life by eliminating ground loop current through the reference. Users can choose between ON/OFF and Proportional control as well as selectable current and voltage outputs. For more flexibility and better resolution for chart recorders, choose any two points between 0 and 2000 mV to correspond to the analog output spans. SPECIFICATIONS Range Resolution Accuracy (@20°C/68°F) Input Impedance pH Calibration Digital: RS485 bi-directional opto-isolated; or analog, galvanically isolated: 0-1 mA, 0-20 mA and 4-20 mA, 0-5 Vdc, 1-5 Vdc and 0-10 Vdc Outputs ORDERING INFORMATION: Setpoint Relay Each HI 22 model is supplied with instruction manual. Alarm Relay 111, single setpoint 122, dual setpoint HI 22 - 1, 24 VDC/AC power supply 2, 115VAC power supply HI 22 ORP: -2000 to 2000 mV; Temperature: -9.9 to 120°C ORP: 1 mV; Temperature: 0.1°C ORP: ±2 mV; ±0.5°C 1012 Ohm Automatic at 0 and 350 or 1900 mV Power Supply Power Consumption Environment Protection Dimensions Weight Contact output SPDT 5A-250 Vac, 5A-30 Vdc (resistive load); fuse: 5A, 250V Contact output SPDT 5A-250 Vac, 5A-30 Vdc (resistive load); fuse: 5A, 250V 115 Vac ±10% or 230 Vac ±10%; 50/60 Hz; fuse: 400 mA, 250 V 15 VA 0 to 50°C (32 to 122°F); RH max. 85% non-condensing IP 54 221 x 181 x 86 mm (8.7 x 7.1 x 3.4’’) 1.4 kg (3.1 lb.) BL 7917 BL 7916 / BL 7917 Pressure (bar) Flow Rate (LPH) 0.5 13.3 1.0 11.7 2.0 10.1 3.0 9.0 ORP Controller and Pump • • • • ORP controller and dosing pump in one compact unit. 4.0 7.8 ±5 mV accuracy with unbeatable performance. Isolated 4 to 20 mA recorder output. Proportional dosing slows the pump down when the measured ORP level approaches the set value which avoids overdosage of oxidizing or reducing agents. • Alarm contact is activated whenever the ORP reading varies more than 200 mV from the set point. • Auxiliary contacts allow the user to attach a mixer or priming pump that is activated only when the pump is dosing. • PVDF, FPM/FKM and PTFE materials are used for parts that come into contact with liquid. 220/240V ±15%; 50/60Hz version available (BL 7917D) ORDERING INFORMATION: SPECIFICATIONS Range Resolution BL 7917U is supplied with discharge and suction valves, polyethylene tubing, 110/115V power cable and instructions. Accuracy (@20°C/68°F) ACCESSORIES: Input Impedance HI HI HI HI HI HI HI HI HI Dosage 46 721101 Pumphead, O-ring and screws 721102 Discharge valve assembly 721103 Suction valve assembly 721004 Injection valve assembly (required) 721005 Foot valve assembly (required) 721008 Ceramic weight (4 pcs.) 7020L 200/275 mV test solution, 500 mL 7091L Reducing solution, 500 mL 7092L Oxidizing solution, 500 mL Flow Rate 1 mV ±5 mV See table above 1012 Ohm proportional, oxidizing or reducing, user selectable Recorder Output 4-20 mA (isolated) Dosing Contact 1 isolated contact, 2A, Max. 240V, resistive load, 1,000,000 strokes Alarm Contact 1 isolated contact, 2A, Max. 240V, resistive load, 1,000,000 strokes Power Supply 110/115V ±15%; 50/60Hz (40W) Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing Dimensions 181 x 221 x 142 mm (7.1 x 8.7 x 5.6’’) Weight HANNA instruments Agricultural Products Catalog ® BL 7917 -999 mV to +999 mV 5th 5 kg (11 lb.) Edition HI 9935 pH & TDS Proportional Control for Fertigation • 2-in-1: pH and TDS • Automatic Temperature Compensation • Alarm Relay HI 9935 is a 2-in-1 pH and TDS controller engineered for dosage of fertilizer solutions in hydroponics. SPECIFICATIONS Range Resolution Accuracy (@20°C/68°F) Input Impedance Calibration Setpoint TDS Conversion Factor Temp. Compensation (TDS) Proportional Control Dosing Contact Alarm Relay HI 9935 measures pH from 0.00 to 14.00 and TDS from 0 to 1999 ppm. Two separate setpoints can be user-adjusted from 4 to 7 pH and 900 to 1800 ppm (mg/L). The relays are activated when pH exceeds the setpoint or TDS falls below the desired value. Two pumps or electro-valves can be wired directly to the controller and be powered through the terminals. Independent proportional HI 9935 settings for pH and TDS can be adjustpH: 0.00 to 14.00; TDS: 0 to 1999 ppm (mg/L) ed from 0 to 90 seconds, 0 to 2.0 for pH pH: 0.01; TDS: 1 ppm (mg/L) and 0 to 400 ppm for TDS. A ground pH: ±0.02; TDS: ±2% F.S. probe can be connected to the appro12 10 Ohm priate terminals to eliminate interference Manual, 2 point for pH and 2 point for TDS, with trimmers on the front panel and prolong the pH electrodes’ life. 2, selectable from 4.00 to 7.00 pH and from 900 to 1800 ppm 0.65 ppm = 1 μS/cm Automatic, 0 to 50°C (32 to 122°F) with ß = 2%/°C Adjustable from 0.00 to 2.00 pH and from 0 to 400 ppm, time cycles from 0 to 90 seconds ORDERING INFORMATION: HI 9935 is supplied with instruction manual. 2 powered terminals for pH and TDS corrections (240 V) Max. 2A, 1,000,000 strokes activated when pH > setpoint and TDS reading < setpoint, respectively 1, activated when pH varies more than a selectable value (0.5 to 2.5 pH) from setpoint or when max dosage time for pH (adjustable from 1 to 10 minutes) elapses; or when TDS differs more than a selectable value (50 to 450 ppm) from setpoint or when max dosage time for TDS (adjustable from 1 to 10 minutes) elapses (isolated, Max 2A-240 V, resistive load, 1,000,000 strokes) Power Supply Environment Dimensions Weight 110/115 Vac ±10% or 220/240 Vac ±10%; 50/60 Hz -10 to 50°C (14 to 122°F); RH max 95% non-condensing 221 x 181 x 86 mm (8.7 x 7.1 x 3.4’’) 1.6 kg (3.5 lb.) HI 9913 pH & EC Proportional Control for Fertigation 1, 24 VDC/AC power supply a=1 2, 115VAC power supply a=2 HI 9935-a ACCESSORIES: HI 7004/1L pH 4.01 buffer sol., 1 L HI 7007/1L pH 7.01 buffer sol., 1 L HI 70442L 1500 ppm cal. sol., 500 mL • 2-in-1: pH and Conductivity • Automatic Temperature Compensation • Alarm Relay HI 9913 is a 2-in-1 pH and conductivity controller engineered for cost-effective dosage of fertilizer solutions in hydroponics. Two separate set points can be user-adjusted from 4 to 7 pH and 1.00 to 4.00 EC (mS/cm). The relays are activated when pH exceeds the set point or conductivity falls below the desired value. Two pumps or electro-valves can be wired directly to the controller and be powered through the terminals. The operator can adjust two independent proportional settings for pH and conductivity. The time cycle is adjustable from 0 to 90 seconds, while the proportional band is 0 to 2.0 for both pH and EC. A ground probe can be connected to the appropriate terminals to eliminate interference and prolong the pH electrodes’ life. SPECIFICATIONS Range Resolution Accuracy (@20°C/68°F) Input Impedance Calibration Setpoint Temp. Compensation (EC) Proportional Control Dosing Contact Alarm Relay Power Supply Environment Dimensions / Weight HI 9913 0.00 to 14.00 pH; 0.00 to 10.00 mS/cm 0.01 pH; 0.01 mS/cm ±0.02 pH; ±2% F.S. 1012 Ohm Manual, 2 point for pH and 2 point for EC, through trimmers on the front panel 2, selectable from 4.00 to 7.00 pH and from 0.00 to 6.00 mS/cm Automatic, 0 to 50°C (32 to 1226F) with ß=2%/°C ORDERING INFORMATION: HI 9913 is supplied with instruction manual. Adjustable from 0.00 to 2.00 pH and from 0.00 to 2.00 mS/cm, time cycles from 0 to 90 seconds 2 powered terminals for pH and EC dosages (240V) Max. 2A, 1,000,000 strokes activated when pH > setpoint and when mS reading < setpoint, respectively 1, activated when pH varies more than a selectable value (0.5 to 2.5 pH) from setpoint or when max dosage time for pH (adjustable from 1 to 10 minutes) elapses; or when conductivity varies more than a selectable value (0.5 to 2.5 mS/cm) from setpoint or when max dosage time for EC (adjustable from 1 to 10 minutes) elapses (isolated, Max 2A-240 V, resistive load, 1,000,000 strokes) 110/115 Vac ±10% or 220/240 Vac ±10%; 50/60 Hz -10 to 50°C (14 to 122°F); RH max 95% non-condensing 221 x 181 x 86 mm (8.7 x 7.1 x 3.4’’) / 1.6 kg (3.5 lb.) 1, 24 VDC/AC power supply a=1 2, 115VAC power supply a=2 HI 9913-a ACCESSORIES: HI HI HI HI 7004/1L pH 4.01 buffer solution, 1 L 7007/1L pH 7.01 buffer solution, 1 L 7031L 1413 μS/cm cal. sol., 500 mL 7039L 5000 μS/cm cal. sol., 500 mL www.hannainst.com/usa 47 Wall Mount Controllers With Great Products, Come Great Results.™ Wall Mount Controllers HI 9914 Chemical Metering Pumps Fertigation Controller The HANNA instruments® Blackstone Series • Backlit LCD • Designed exclusively for fertigation • Alarm system • • • • HI 9914 is a wall mounted fertigation controller, designed to meet specific process control requirements in agricultural, horticultural and hydroponics applications. The controller is provided with two measuring channels, one for pH and one for conductivity. The readings are displayed simultaneously on two independent LCDs with backlight. The conductivity probe is designed with a built-in temperature sensor which allows the controller to automatically compensate for the temperature effect. The differential input and the use of a matching pin prevent grounding problems and thus ensure longer life to the pH electrode. The controller includes two regulators for pH and conductivity, that can be adjusted from the front panel by setting two independent thresholds. The conductivity and pH controls are time separated and a timed operation mode avoid overdosing of fertilizer or acid. The controller status is indicated by LED indicators on the front panel. Moreover, the equipment is provided with a three-level sensor, to control the water level, the alarm condition and the irrigation sequences. The instrument also features an alarm system, which is activated when an unusual working condition occurs. A humidity detector can be used to stop the controller if any leakage is detected. Designed for all environments Reliable High quality material Ideal for dosing nutrients & acids Blackstone's positive displacement solenoid driven pumps use a minimum number of moving parts, therefore reducing the chance of mechanical failure. Part wear and oiling associated with motor driven pumps (ballbearings, gear drives and cams) are not present in these pumps. Blackstone pumps are more accurate than standard pumps with the positive displacement design ensuring each stroke is identical to the strokes before and after it, thus keeping the flow rate constant. A wide range of Blackstone pumps with different dosing capacities is available for your specific dosing needs. Each pump is supplied with discharge and suction valves. HANNA instruments® also produces polyethylene tubing, injection fittings, ceramic weights and replacement parts. Valve/Hose Assembly Diagram Water nozzle, circulation pump, feeding pump and alarm are equipped with relays. SPECIFICATIONS HI 9914 Range Resolution Accuracy (@20°C/68°F) 0.00 to 10.00 mS/cm; 0.00 to 14.00 pH 0.01 mS/cm; 0.01 pH ±5% F.S.; ±0.02 pH Manual, 1 point for EC with slope trimmer; 2 point for pH with offset and slope trimmers Calibration Setpoint Analog Output Timer Feed OK Output Humidity Sensor Water Nozzle Output Circulation Pump Output Feeding Pump Output Alarm output Water Level Inputs User Input External FILL Button Power Supply Environment Dimensions Weight 2, selectable from 0.50 to 10 mS/cm and from 0.5 to 14.0 pH 0-5V±5% (0.5V/mS); 0-7 V±5% (0.5 V/pH) Adjustable from 1 to 10 minutes 12V, 15 mA Activated if resistivity is below 220 KOhm 2A, 220V relay 2A, 220V relay 2A, 220V relay 2A, 220V relay Contact type water level sensors Contact type switch Contact type push-button 110/115 Vac ±10% or 220/240 Vac ±10%; 50/60 Hz -10 to 50°C (14 to 122°F); RH max 95% non-condensing 221 x 181 x 90 mm (8.7 x 7.1 x 3.5’’) 1.75 kg (3.9 lb.) ORDERING INFORMATION: ACCESSORIES: HI 9914 is supplied with instruction manual. HI 3003/D Glass-body conductivity probe with DIN connector HI 7004L pH 4.01 buffer solution, 500 mL HI 7007L pH 7.01 buffer solution, 500 mL HI 7010L pH 10.01 buffer solution, 500 mL HI 7031L 1.41 mS/cm cal. sol., 500 mL HI 7039L 5.00 mS/cm cal. sol., 500 mL HI 70300L Electrode storage solution, 500 mL HI 7061L Electrode cleaning solution, 500 mL 1, 24 VDC/AC power supply a=1 2, 115VAC power supply a=2 HI 9914-a 48 HANNA instruments Agricultural Products Catalog ® 5th Edition NECK Versatility SPECIFICATIONS Blackstone pumps have been designed to meet the ever changing needs of industry. To accommodate diverse applications, the pumps can be easily mounted anywhere in your plant with their broad, flat base and mounting holes for tank, shelf or floor mounting (horizontal). The rear of the pump housing also provides mounting holes to facilitate vertical mounting: wall, tank or machine. With the pump valve assembly and unit controls both located on the front of the pump, there is never a problem with installation or flow adjustments. Max Output Pump Casing Simple Operation Blackstone pumps are equipped with a single control for pump output. The external Flow Rate Control (potentiometer) on the face of the pump allows you to adjust the percentage of flow from 0 to 100% of the pump's rated capacity. This feature eliminates the need to worry about stroke lengths and power settings. An LED indicator lights up each time a stroke begins. This allows the user to assess the stroke rate from a distance. High Quality Materials Blackstone pumps have been manufactured with the highest level of mechanical precision, from materials chosen for their inherent ability to resist the effects of aggressive chemicals. When you select a Blackstone pump, you are eliminating the time consuming effort involved in picking the right material for your application. Materials BL Series See table below Fiber-reinforced polypropylene Pumphead in PVDF, diaphragm in PTFE, glass ball valves and O-rings in FPM/FKM polyethylene 5 x 8 mm tubing and 3/8" injection fitting Self-priming Power Supply Max Power Consumption Protection Environment Dimensions Weight Max height: 1.5 m (5 feet) 110/115 Vac or 220/240 Vac, 50/60Hz Approx. 200 W IP65 0 to 50°C (32 to 122°F); RH max 95% non-condensing 165 x 194 x 121 mm (6.5 x 7.6 x 4.8’’) Approx. 3 kg (6.6 lb.) ORDERING INFORMATION: ACCESSORIES: BL BL BL BL BL BL BL BL BL BL BL BL BL BL HI 721101 Pumphead, O-ring and screws HI 721102 Discharge valve assembly HI 721103 Suction valve assembly HI 721004* Injection valve assembly HI 721005* Foot valve assembly HI 721008 Ceramic weight (4 pcs.) * Required for operation 1.5-1 1.5 LPH flow rate, 110/115 Vac power supply 1.5-2 1.5 LPH flow rate, 220/240 Vac power supply 3-1 2.9 LPH flow rate, 110/115 Vac power supply 3-2 2.9 LPH flow rate, 220/240 Vac power supply 5-1 5.0 LPH flow rate, 110/115 Vac power supply 5-2 5.0 LPH flow rate, 220/240 Vac power supply 7-1 7.6 LPH flow rate, 110/115 Vac power supply 7-2 7.6 LPH flow rate, 220/240 Vac power supply 10-1 10.8 LPH flow rate, 110/115 Vac power supply 10-2 10.8 LPH flow rate, 220/240 Vac power supply 15-1 15.2 LPH flow rate, 110/115 Vac power supply 15-2 15.2 LPH flow rate, 220/240 Vac power supply 20-1 18.3 LPH flow rate, 110/115 Vac power supply 20-2 18.3 LPH flow rate, 220/240 Vac power supply Blackstone pumps are supplied with the highest quality material as standard equipment, not optional. The diaphragm utilizes one-piece construction of PTFE, which unlike conventional laminated diaphragms will stand up to the test of time and wear. Ball valves are constructed in glass. The pumphead and O-rings are all made of PVDF, PTFE and FPM/FKM which offer unsurpassed resistance. Rugged Design Blackstone pumps are completely sealed during assembly and offer IP65 protection against splashes and spills providing excellent protection even in hostile environments. The fiber-reinforced polypropylene housing stands up to aggressive chemicals while offering superior strength under tough industrial conditions. Part# Output BL 20 BL 15 BL 10 BL 7 LPH 18.3 15.2 10.8 7.6 BL 5 BL 3 BL 1.5 5.0 2.9 1.5 Rated Pressure With Large Diaphragms GPH BAR PSI 4.8 0.5 7.3 4.0 1 14.5 2.9 3 43.5 2.0 3 43.5 With Small Diaphragms 1.3 7 101.5 0.8 8 116 0.4 13 188.5 Strokes/min 120 120 120 120 120 120 120 www.hannainst.com/usa 49 Chemical Dosing Pumps With Great Products, Come Great Results.™ Transmitters/Level Controllers HI 8666 RH/°C Transmitter • Sintered metal cap • 4-20 mA output • Dual-range transmitter The highly accurate humidity and temperature transmitter can be mounted anywhere in the greenhouse to relay temperature and humidity values via an analog signal to remote panel meters or controllers. SPECIFICATIONS HI 8666 RH: 0% (4 mA) to 100% (20 mA); Temperature: -20°C (4 mA) to 60°C (20 mA) Range Precision Response Time Power Supply Environment Panel Cutout Dimensions Weight RH: ±2% (5% to 95% RH); Temperature: ±1% F.S. 6 seconds without sintered filter; 60 seconds with filter 10-30 Vdc 0 to 60°C 73 x 42 mm (2.9 x 1.6”) 79 x 49 x 150 mm (3.1 x 1.9 x 5.9”) 150 g (5.3 oz.) ORDERING INFORMATION: HI 8666 is supplied with sensor protective cap, mounting brackets and instructions. ACCESSORIES: HI HI HI HI 7102 Calibration chamber 7111/P Spare saturation LiCl salts for low humidity calibration (15 g, 6 pcs) 7121/P Spare saturation NaCl salts for high humidity calibration (33 g, 6 pcs) 710011 Probe sintered cap HI 7871 • HI 7873 Level Controllers HI 7871 and HI 7873 mini level controllers are ideal for liquid level control over distances of up to 100 meters (330 feet). They are highly compact and will fit into tight spaces. These easy-to-use controllers are ideal for nearly any liquid level application, such as nutrient tank control in farming and hydroponics. These compact controllers will prevent one or more of the nutrient tanks from running dry, assuring that the nutrient mix is always correct. A complete liquid level measuring system requires: 1) A controller (HI 7871 or HI 7873) 2) A bar holder with amplifier circuitry (HI 7874) 3) A package of measuring bars (HI 731324) 4) An undecal connector (HI 7164) HI 7871 requires 3 bars, one each for low and high levels and the third as a consent sensor. HI 7873 requires four bars with the additional bar used for overflow measurement. SPECIFICATIONS Transmission Electrical Connection Level Adjustment Level Indication HI 7871 HI 7873 Transmitter Max 100 meters (330 feet) HI 7164 undecal connector (not included) High and low High, low and overflow High and low High, low and overflow 3, HI 731324 (not incl.) 4, HI 731324 (not incl.) (See accessories) (See accessories) HI 7874 (not included) Output Contact 1 relay (2A/250 Vac, 30 Vdc) 2 relays (2A/250V, 30 Vdc) Sensor Bars Power Supply Environment Dimensions Weight 50 models “/115”: 110/115 Vac; 50/60Hz; models “/220”: 220/240 Vac; 50/60Hz 0 to 50°C (32 to 122°F); RH max 85% non condensing 83 x 53 x 95 mm (3.1 x 1.9 x 3.8’’) 250 g (8.8 oz.) ORDERING INFORMATION: HI 7871/115 (115 Vac) is supplied complete with mounting brackets and instructions. HI 7871/220 (220 Vac) is supplied complete with mounting brackets and instructions. HI 7873/115 (115 Vac) is supplied complete with mounting brackets and instructions. HI 7873/220 (220 Vac) is supplied complete with mounting brackets and instructions. ACCESSORIES: HI 7874 Level transmitter with internal amplifier HI 7164 Undecal connector HI 731324 Stainless steel threaded measuring bars (5) HANNA instruments Agricultural Products Catalog ® 5th Edition HI 8000 Series HANNA instruments® Acid Injection/pH Control Systems True pH and Alkalinity control solutions for variable flow greenhouse irrigation HANNA instruments®, the world’s leader in pH technology has worked with leading greenhouses to develop advanced system solutions for covered crops of any type. Each system can precisely control pH and alkalinity from 3GPM up to 200GPM. Incorporating combined pH and flow control technology, the HANNA solution offers features and functionality found no where else in the industry. Each system can be installed in-tank or directly in-line and is custom configured and programmed to meet the pH and alkalinity requirements of any greenhouse; any crop! HANNA’s Injection systems can be found in a number of notable greenhouses: Orie Van Wingerden Greenhouses NJ, Van Wingerden Greenhouses NJ, Riverside Greenhouse NJ, Oak Hill Greenhouse MA. Additional installations include such greenhouse leaders as Van Wingerden Greenhouses WA. Advanced features of HANNA’s HI 8000 Series Controllers: • Free installation and start up • Combined pH and flow control technology • Multiple measuring point monitoring and control from the point of injection to the point of delivery — all from one central controller • Precise fertilizer control with multiple point EC monitoring • Automatic time or volume control from 8 to 32 zones (solenoid valves) • 10 easy to use programs for a variety of crops and irrigation timetables • Programmable starts for “hand watering” or time scheduled activation • Multiple alarm settings to provide maximum safety and reliability • PC interface capability for remote monitoring and control • Fully upgradeable to a 4 fertilizer injection control system • 3 year warranty on the HI 8000 Controller and free unlimited technical support Quality and Service The HANNA systems are above all reliable, durable and require little to no maintenance and each unit is backed by impeccable training and support… …just ask our clients! www.hannainst.com/usa 51 Acid Injection & Control With Great Products, Come Great Results.™ Acid Injection & Control HI 8000 Series: The heart of HANNA’s acid injection/pH Control Systems 8 1 2 7 3 4 6 Wall Mount 5 1. Fertilizer and acid injection indicators (LEDs) 8 2. Main pump and alarm indicators (LEDs) 3. Multiple zone valve indicators (LEDs) 4. Waterproof NEMA 4X casing 1 5. Multiple connection ports 7 6. Up to 62 selectable “screens” for readouts and programming 2 7. Touch keypad 8. Quick reference guide 3 Panel Mount 52 HANNA instruments Agricultural Products Catalog ® 5th Edition Acid Injection & Control With Great Products, Come Great Results.™ BL Pumps Injection Valves Bleeder Valves Quick Release Connections Direct Injection Sprayer Nozzle SPECIFICATIONS HI 8000 Series F1 Controllers Range pH : 0.0 to 14.0; EC: 0.0 to 10.0 mS/cm Resolution 0.1 pH / 0.1 mS/cm Accuracy (@20°C/68°F) pH: ±0.0546; EC: ±0.078 mS/cm Typical Inputs 2 pH electrodes, 3 conductivity probes, 4 fertilizer tanks, 1 acid tank, 5 tank level controls, 1 mixing tank level control, 2 differential pressures, 1 irrigation counter, 1 temporary break, 1 conditional stoppage Typical Outputs 2 non-consent alarms, up to 32 zone valves, 2 filter flushing, pump, agitator, 4 fertilizer tank electro-valves, 1 pH tank electro-valve Number of Programs Program Method Irrigation Capacity Irrigation Control Readout Power Supply Environment Dimensions 10 With keypad or through a PC using proprietary software 8, 16, 24 and 32 zone valves time/volume control, 1 to 6 different timetables per program, 20-digit, 4 level LCD with graphic symbols and messages 115V/220V; 50Hz/60Hz HI 8002: NEMA 4X specifications Wall mounted: 280 x 330 x 165 mm (11.2 x 13.2 x 6.6”); Panel mounted: 178 x 260 x 115 mm (7.1 x 10.4 x 4.6”) Weight Wall mounted: 4.95 Kg (11 lb.); Panel mounted: 3.4 Kg (7.5 lb.); ORDERING INFORMATION REQUIRED ACCESSORIES HI 98143-22 pH/EC isolated transmitter, non-sourcing current type with 4-20 mA output (2 required) Family 0: Fertigation controller with priority for pH and EC control 1: Fertigation controller with flow control (irrigation counter) 2: Fertigation controller with flow control, pH dosage and EC monitor 4: Fertigation controller with water mixing system (circulation pump) Version 1: panel mounted 2: wall mounted (not for “4” family) Number of sectors 01: 8 sectors 02: 16 sectors 03: 24 sectors 04: 32 sectors (where available) HANNA flat-tip In-line pH electrodes fit right into your irrigation system. Firmware language 00: English 01: Spanish 02: Italian 03: Portuguese Use the HANNA HI 60542 screw type electrode holder for a perfect fit. 04: Dutch 05: French 06: Greek 07: Arabic Power Supply U: 115 Vac D: 230 Vac OTHER ACCESSORIES HI 80 HI 60542 2" NPT in-line PVC and ORP electrode holder ideal for installation directly in pipes. The HI 60542 has been designed specifically to be used with HANNA’s ¾" process pH and ORP electrodes. www.hannainst.com/usa 53 Fertigation Complete Greenhouse Fertigation Control HI 10,000 series Fertigation Systems HANNA instruments®, the world’s leader in EC and pH control technology has worked with leading growers to develop advanced system solutions for crops of any type. The HANNA Fertigation System provides precise control of pH and fertilizer injection. Unlike flow driven systems of the past, the HANNA Fertigation System constantly measures the actual EC and pH the water, allowing the system to add the precise concentration of fertilizer directly to the irrigation supply. The HANNA System is a bypass system which does not Above all, limit line flow or HANNA pressure. This systems allows the user to are reliable, inject fertilizer from durable and 5 GPM up to 300 require little to no maintenance. GPM accurately. Each of our units are backed by The HI 8000 series impeccable training and support…just controller included ask our clients! with the system has 10 programs that allow the user to set various EC and pH values for a variety of plants. Each system allows the injection and mixing of up to 4 fertilizers. If preferred, each fertilizer injector can be set to a specific percent, allowing the user to mix combination fertilizers from basic N - P - K elements, providing a considerable cost savings. The HANNA Fertigation System also controls up to 32 irrigation valves for complete automation of the fertigation process. Quality and Service Features • Precise control via continuous EC and pH monitoring • 8 to 300 GPM flow rate range • 65 to 75 PSI operating range Request a Free Brochure or CD! 2 CD features the HI 10,000 at a customer Location as well as interviews and system overview. Year Warranty or Find out more online! http://www.hannainst.com/fertigator (excluding probes) HANNA’s Fertigation and pH Control Systems can be found in a number of notable greenhouses: Van Wingerden Greenhouses NJ, Gro-Rite NJ, Van Vugt NJ, Michael’s Greenhouse CT. Additional installations include such greenhouse leaders such as OVW Greenhouse NJ, and De Groot Greenhouse NJ, Van Wingerden Greenhouses WA. Pro’s Choice • Bypass system — unit does not interfere with main line flow SPECIFICATIONS • 3 fertilizer injectors and 1 mild acid Range • Make your own combination fertilizer Resolution — Each fertilizer can be set to a specific percent. 0.1 pH / 0.1 mS/cm Accuracy (@20°C/68°F) • Control over 32 valves — valves can be controlled sequentially, or x 2, x 3 …up to x 8 at once • 10 programs for various EC and pH set-points and fertilizer percentages HI 8000 Series F1 Controllers pH : 0.0 to 14.0; EC: 0.0 to 10.0 mS/cm Typical Inputs Typical Outputs pH: ±0.0546; EC: ±0.078 mS/cm 2 pH electrodes, 3 conductivity probes, 4 fertilizer tanks, 1 acid tank, 5 tank level controls, 1 mixing tank level control, 2 differential pressures, 1 irrigation counter, 1 temporary break, 1 conditional stoppage 2 non-consent alarms, up to 32 zone valves, 2 filter flushing, pump, agitator, 4 fertilizer tank electro-valves, 1 pH tank electro-valve • Programs can be triggered by time, external switching, and/or flow Number of Programs Program Method With keypad or through a PC using proprietary software • Flow activated to allow for spot watering — timer adjustable Irrigation Capacity 1, 4, 8 and 32 zone valves • Control agitators and filter cleaning • Alarm Control and Redundant Monitoring • GSM compatible for remote monitoring and control from PC 54 Irrigation Control Readout time/volume control, 1 to 6 different timetables per program, 20-digit, 4 level LCD with graphic symbols and messages Power Supply 115V/220V; 50Hz/60Hz Environment HI 8002: NEMA 4X specifications Dimensions Wall mounted: 280 x 330 x 165 mm (11.2 x 13.2 x 6.6”); Panel mounted: 178 x 260 x 115 mm (7.1 x 10.4 x 4.6”) Weight HANNA instruments Agricultural Products Catalog ® 10 5th Wall mounted: 4.95 Kg (11 lb.); Panel mounted: 3.4 Kg (7.5 lb.); Edition With Great Products, Come Great Results.™ Warranty/Returns Limited Warranty HANNA instruments® products are manufactured in our ISO 9001 facilities, meeting the highest quality standards in the industry. HANNA’s high standards also apply should a product be returned due to defects in material or workmanship. Our extensive warranty extends up to three years on some products. Limitations: Warranted products may be returned for repair or replacement only at the discretion of HANNA instruments®. In some circumstances, remedy may constitute refund for the price paid for the product. The warranty period commences from the original date of sale to the user or a maximum of 18 months from factory ship date. Warranty is valid only when the product is used under normal conditions and in accordance with operating limitations and prescribed maintenance procedures. The express warranty stated previously is the only express warranty given by HANNA to the end-user buyer. HANNA expressly disclaims any warranties implied by law, including but not limited to warranty of merchantability of fitness for a particular purpose. HANNA shall not be liable for any individual or consequential damages of any kind for breach of any warranty, negligence, on the basis of strict liability or otherwise. HANNA’s warranty periods are: 5 3 3 2 2 2 2 2 1 1 6 6 years years years years years years years years year year months months HI 221, HI 222 & HI 223 HI 901 & HI 902 Wine Line Photometers, HI 120, HI 110, HI 250 & pH 300 series, HI 4200 series, HI 255 Bench Top Meters HI 10,000 Fertigator, Suction Lysimeter Portable Meters Bench Meters not mentioned above Printing Meters Stirrers & Industrial Meters Dosing Pumps Waterproof Testers Testers & Pocket-size Thermometers Electrodes & Probes Instrument Service: Warranty and non-warranty service, replacement, recalibration and repairs are performed by factory trained service technicians at HANNA’s Woonsocket, RI Technical Service Center. All items must have a Return Goods Authorization (RGA) number that can be obtained by contacting the HANNA Technical Service Department. The RGA number should be clearly marked on the outside of the box and the unit shipped prepaid and insured. Any product not bearing an RGA number will be refused. All products returned for warranty repair or replacement MUST be preceded or accompanied with proof of purchase, such as the original invoice or packing slip. Under special circumstances it may be deemed necessary by HANNA instruments® to issue a Return In Advance (RIA). In such cases, the defective materials must be returned to HANNA within 30 days. Materials not returned within 30 days become chargeable. Materials must be packed properly to avoid damage during transport, which would render the warranty null and void. The sender is responsible for expediting any damage claims placed against the carrier. A flat minimum service charge of $60.00 (per hour) applies to non-warranty repairs or recalibration. Any materials returned for repair which are considered non-warranty may be serviced at the previously stated hourly cost (excluding parts) following subsequent notification and approval of such. Product Return and Exchange Returning Merchandise: Should an instance occur when a product may need to be returned for exchange or credit, or should a discrepancy occur in a packing slip, HANNA instruments® must be contacted to obtain a Return Goods Authorization Number (RGA). Please follow these steps: 1. Within 30 days of receipt of merchandise call HANNA’s Technical Service Department to obtain a Return Goods Authorization Number. 2. HANNA will issue a Return Goods Authorization Number. 3. The number must be clearly marked on the outside of the package being returned. Shipments not bearing a Return Goods Authorization Number will be refused. 4. Credit returns may be subject to a 25% restocking fee. Terms and Conditions Return shipments must meet the following requirements to be accepted for credit: 1. Products must be returned in the original packaging with labeling not defaced. All items returned will be inspected for credit worthiness. Credit will only be issued for product returned in like-new condition. No credit will be issued for product, which is not received in like-new condition. 2. All freight charges are the responsibility of the customer. 3. All chemicals and reagents being returned must be packaged in accordance with U.S. Department of Transportation regulation. Only unopened chemicals and reagents may be returned. HANNA instruments® reserves the right to change or modify the design of its products at any time without advance notice. www.hannainst.com/usa 55 HANNA instruments®, Inc. Highland Industrial Park 584 Park East Drive, Woonsocket, RI 02895 phone: (800) 426-6287 fax: (401) 765-7575 e-mail: agriculture@hannainst.com web: www.hannainst.com Authorized Distributor w w w. h a n n a i n s t. c o m / u s a P/L AGCATED5 1.0 PRINTED IN USA